Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSOFFICE 1 2 3 4 Y: PLANNING & DEVELOPMENT SERVICES s BUILDING & CODE REGULATION DIVISION 2300 Virginia Avenue n , Ft. Pierce, FL 34982-5652 772-462-1553 APPLICATION FOR ALUMINUM STRUCTURES PERMIT ALL INFO MUST BE COMPLETE & FILLED IN TO BE EPTED PROJECT INFORMATION LOCATION/SITE ADDRESS: 318 Shady Ln Port Saint Lucie. FL 34 PROJECT NAME: Quick SITE PLAN N E: PROPERTY TAX ID #: 3419-510-0081-000-2 LEGAL DESCRIPTION (attach extra sheets if necessary): River Park - Unit 2 - Lot9- Blk 12 St. Lucie County 5. PLAT BK 10 PAGE rIZ BLOCK 12 LOT 1 6. PARCEL SIZE: ACRES/SQ FT. ,_L LOT DIMENSIONS 2 e Q � 1 7. SETBACKS (ACTUAL) FRONT: BACK: 35�I s RIGHT SIDE: 7,Ce LEFT SIDE: 8. TYPE OF STRUCTURE (CHECK ALL APPROPRIATE BOXES FOR EACH6N,[%jVERY TYPE OF STRUCTURE) Y 'TYPE OF CONSTRUCTION N = New A = Addition R = Rebuild SG = Slab on Grad(10 SR = Raised Slab � WD = Wood Deck DIMENSIONS SQUARE FEET OF CONSTRUCTION IXI SCREEN ROOM N S6 NEW EXISTI G X ® CARPORT/PATIO ROOF N SG ,E NEW EXISTING 10 X 370 ❑ HABITABLE GLASS ROOM ❑ NEW ❑ EXISTING X ❑ CAT 1, 2 OR 3 SUNROOM ❑ NEW ❑ EXISTING X ❑ ALUMINUM COMP. SHED ❑ NEW ❑ EXISTING X ❑ POOL ENCLOSURE ❑ NEW ❑ EXISTING X ❑ M H ROOF OVER ❑ NEW ❑ EXISTING X ❑ ROOF SYSTEM OVER EXISTING ACCESSORY STRUCTURE ❑ NEW ❑ EXISTING X ❑ OTHER: ❑ NEW ❑ EXISTING X ❑ ALUM POOL FENCE Linear tcet TOTAL SQUARE FOOTAGE OF CONSTRUCTION 9. VALUE OF CONSTRUCTION: $ 5,625.00 The value of construction is used to determine the amount of permit fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction activities. If the value is $2500 or more, a RECORDED Notice of Commencement must be submitted PRIOR TO FIRST INSPECTION. SLCCDV Form No.: 001-02 ReK04126/2010 OWNER INFORMATION NAME: Robert & Brenda Quick ADDRESS: 318 Shady Lane Port Saint Lucie, FL 34952 CITY: Port Saint Lucie STATE: FL ZIP 34952 PHONE (DAYTIME): (77ZJ 828-1450 EMAIL: FILL IN NAME AND ADDRESS BELOW IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE: FEE SIMPLE TITLEHOLDER: ADDRESS: CITY: STATE: ZIP PHONE (DAYTIME): ( ) CONTRACTOR INFORMATION STATE OF FLORIDA REG./CERT #: RX 1 1 0 6 6 91 9 ST. LUCIE COUNTY CERT #: 4763 BUSINESS NAME: Pioneer Screen Co. Inc. II QUALIFIER'S NAME: Michael Newman ADDRESS: 1682 SW Biltmore St Port Saint Lucie FL 34984 CITY: STATE: ZIP PHONE (DAYTIME): 772 )340-4393 FAXNO.772-340-4626 email: pioneerscreen@msn. co ARCHITECT/ENGINEER: Do Kim & Associates ADDRESS: PO BOX 1003 CITY: Tampa STATE: FL ZIP 33679 PHONE (DAYTIME): 33) 857-9955 NOTE: IF APPLICABLE, SUBCONTRACTOR AGREEMENTS MUST BE ATTACHED TO APPLICATION FOR ROOFING, ELECTRIC, PLUMBING, AND HVAC ZONING REQUIREMENTS All such structures will be subject to the requirements of the ST. LUCIE COUNTY LAND DEVELOPMENT CODE. ❑ 2 scaled plot plans showing lot size, dimensions of existing host structure, and proposed aluminum addition. All setbacks including front, side, rear and distance between adjacent property structures in MH Parks shall be indicated on the plot plan. ❑ 2 sets of color photos for all storm damaged areas to be reconstructed. One picture must include house address number for inspection verification. ( not required for construction unrelated to storms) OFFICE USE ONLY SECTION � rl �,p� TOWNSHIP RANGE 1 "'1,� MAP NO. �n / ' V Additional ZONING 1 ' LAND USE (� `I LOT CVG % `� t 1/ `14 Permits "� Required REPORT L� BIMS FEE $ MISC FEES $ TOTAL FEES $ CODE BUILDING & ZONING REVIEW FRONT PLANS VALL II: OF CONSIRI ACTION REVIEW COUNTER ZONING SUPERVISOR EXAMINER VEGET TION USING ICC TLABLE�j DATE COMPLETE i � �� X � A% ' INITIALS CERTIFICATION: This application is hereby made in order to obtain a permit to do the work and installations as indicated, and to obtain a certificate of capacity, if applicable, for the permitted work. NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE TO APPLICANT: IN THE EVENT IT IS NOT YOUR RIGHT TITLE OR INTEREST THAT IS SUBJECT TO ATTACHMENT, THE APPLICANT DOES HEREBY MAKE A GOOD FAITH PROMISE TO DELIVER A COPY OF THE ATTACHED CONSTRUCTION LIEN LAW NOTICE TO THE PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT, AND DOES SO AS A CONDITION PRECEDENT TO THIS PERMIT 1. If utilizing the AAF Guide to Aluminum Construction in High Wind Zones, I the Contractor/Owner Builder hereby certify that the components being used, fasteners type and fastening pattern meet all the requirements for the designated wind zones established by the county and take full responsibility for complying with the submitted design of the structure being permitted. 2. I further certify that all the foregoing information is accurate, that no work or installation has commenced prior to the issuance of a permit and that all work shall be performed in compliance with all applicable laws regulating construction and zoning in this jurisdiction. 1 understand that separate permits may be required for ELECTRICAL, and HVAC, etc., not otherwise included with this building permit application. 3. 1 , the Contractor / Owner B ' er, have verified that the existing foundation 8eets the requirements of the Engineer of Record and ' n adequate c ion to withstand the uplift and weight -of the a mum structure said structure will not exceed the print of the r cture that was in existence prior t 6mova1 by storms. OR CONTRACTU SIGNATURE STATE OF FLORIDA COUNTY OF '+, L "c <_ The foregoing instrument was acknowledged before me me this day of ; U,rt , 20 it , by M i C "a e% dC ►,J ma.n who is personally known V_ to me, or who has produced as ide tification. Signature of Notary IMPORTANT NOTICES: STATE OF FLORIDA COUNTY OF SA--. L_L c- i .{ The foregoing instrument was acknowledged before me hd me this �^2- day of ltsr+t , 20 11 by �e_LJYY-Nar, who is personally known ---%,,t6me. or who has produced as "OtRLY S WALLAM MY COMMISSION # DD�M* Rf EXPIRES November 03, 2012 1'` FloridallotarvService.com 511VI RLY S W4LLACE `1y COMMISSION # D835305 i"XPIRES Novembef, 03, 2012 • TWO (2) SIGNATURES AZFE REQUIRED. EACH SIGNATURE MUST BE NOTARIZED7r7XPPL:YINl5T0 t'r" BUILDING PERMIT AS AN OWNER/BUILDER, THE OWNER MUST PERSONALLY APPEAR, IN THE OFFICE LISTED ON THE FRONT OF THE APPLICATION, TO SIGN THIS APPLICATION & THE OWNER/BLDR AFFIDAVIT. • ALL SIGNATURES ON APPLICATION SUBMITTED SHALL BE ORIGINAL, SIGNED IN INK. COPIES, FAXES, OR STAMPED REPRODUCTIONS ARE PROHIBITED. • WHEN A PERMIT IS AVAILIBLE FOR ISSUANCE BUT IS NOT PICKED UP WITHIN THIRTY (30) DAYS AFTER NOTIFICATION OF AVAILIBILITY, IT WILL BE VOIDED. IF THE APPLICATION IS RESUBMITTED, AN ADDITIONAL FEE WILL BE CHARGED. PLAN REVIEW SPECIFICATION CHECKLIST PLEASE PROVIDE ONE OF THE FOLLOWING: ❑ 2 Sets of Detailed Plans: Dated, Signed & Sealed by an Engineer or Architect holding a Florida State professional license. ❑ 2 Sets of Detailed Plans: Designed in accordance with the AAF Guide to Aluminum Construction in High Wind Areas. ❑ 2 Sets of Detailed Plans: Designed in accordance with any Approved Manual per fs-489.113. (I) ANY PLANS SUBMITTED WITHOUT COMPLYING WITH THE FOLLOWING SHALL BE RETURNED WITHOUT APPROVAL. ALL PLANS MUST BE IN INK AND ANY NOTATIONS IN PENCIL WILL NOT BE CONSIDERED A PART OF A SUBMISSION. • All plans must be legible and must be designed in Architect's Scale on pages which are 81/2" x I I" or larger. • All relevant tables & details, if using a manual, must be properly highlighted and must match design checklists & drawings. • The plan view must include all dimensions; the location of the host structure and all materials must be sized and identified thereon. • All elevations must be shown, including 4`h wall detail, dimensions and all material must be sized and identified. • All primary and secondary carrier beams, spans, spacing, gauges must be shown [Example: 2" x 8" x .072"]. • All methods of fastening or other details which are relevant to the design must be identified on the Plans. • All upright column heights, sizes, spacing and gauges must be shown as follows: [Example: 3" x 3" x .050"]. • All chair -rails, roof purlins, girts, channels, knee -bracing, k-bracing, cable bracing or any other required component must be sized and identified. • All ridge beams and super gutter or fascia attachments must be identified. • All roof pans or composite panels, with gauges and spans, must be sized and identified. • All footing, slab and ISO pier designs must be on the plans, per the Architect / Engineer's plans & specifications. • All light metal alloys which are utilized shall be designed in conformity with the Florida Building Code of 2007, Chapter 20, including 2006 revisions. • Barrier railings, if utilized, shall have all materials, fasteners and height specified and shall have self -closing, self - catching gates with picket spacing. (II) SITE CONSTRUCTED SHEDS, HAVING ANY ALUMINUM COMPONENT, SHALL MEET ALL OF THE ABOVE REQUIREMENTS AND THE FOLLOWING ADDITIONAL ITEMS: (A) 2 copies of the current product approval [i.e. N.O.A. or State of Florida approval] with the proposed "opening" or cladding component highlighted and with fasteners and design pressures, per FBC 1714, clearly identified. (B) 2 electric schematics, in accordance with the N.E.C., if applicable. (C) Design pressures, per ASCE-7, identified on the openings of all Plans. (III) HABITABLE ROOMS/ADDITIONS DESIGNS SHALL MEET ALL OF THE ABOVE REQUIREMENTS, EXCEPT AAMA SPECIFICATIONS, AND CHAPTER 13 OF THE FLORIDA BUILDING CODE. (IV) SUNROOMS (as defined in R202 and FBC 2002.6) MAY BE CONSTRUCTED, SO LONG AS THEY MEET ALL OF THE ABOVE REQUIREMENTS AND MUST BE IN STRICT COMPLIANCE WITH AAMA/NPEA/NSA2100.02 AND MEET THE FOLLOWING ADDITIONAL ITEMS: (1) The designer or engineer will state on all Plans, which Category of Design [3.1.2] will be used, inclusive of the definition. (2) If designing a Category 4 or Category 5 structure, as defined in the current Edition of 3.1.2.4 and 3.1.2.5, proper energy calculations and long form equipment sizing calculations shall be required, pursuant to Chapter 13 of the current State of Florida Building Code. (V) MOBILE HOMES (FAC 15C-2.0081 - FAC 15C-2.0072): ALL STRUCTURES ADJACENT TO OR NEW ROOF SYSTEMS (Pan or Composite) OVER EXISTING ADJACENT STRUCTURES TO A MOBILE HOME SHALL REQUIRE: (a) A 4"' wall or a current, signed original manufacturer's attachment approval letter which includes the model number, serial number and current owner's name and street address. (b) That the complete guide to H.U.D. specifications be strictly adhered to. (c) A Certified Florida Engineer may design the manner of attachment of the proposed structure to the host house but shall assume full responsibility for both structures' integrity by site specific documentation. 06/13/2011 09:41 3404626 Pioneer sCre-'e­ri'C"o". 1,3c. 1682 SW BiltIftore St Port Saint Lucie, Fl. 34984 F 0; 7 0, t A C� THE CIRCUIT COURT SAINT LUcIE C O-rH CULL *SEPHE'SM' j,� — f9LE* 359016006108/2011 8110- AMOR &)OK 3299 PAGE 1819 - 18'46 RECORDING: 510,00 '9 DOc TYPe: NC PAGE 01 CIP p A, Rrjp i 341 81 t )Ck C C? E� RAL DES(- kRTION'OE 0­0`R0VEWRVr': Ins+Zallation �f n -CS 14, ad,4-,C4� C'r jr py, "1 4;�j, r t, TRAf "TO K"s'SAME Atkk5 AND pp -sF 1682 sw Pioneer scTeen 0. r i! S t Port 1.2 NA'4Z. ADEIRL&Sks,�L, FH4-. DMS ntr Upi.in -.3 Wr-r:j A7� 1'. jj)p RF i. hND Pw()*4'F !xlc! 4, t .11 U -or ­k Y:E. mq�jjfss -OiD PRON't!YIN.gD� wal 'A7 A:-n. zh?fr., "Ift law c;•', My,; .!;-,a Unless. a ;jff­rc:j; PH"( Nal"C'mad pro-lide Impsts", - Rorida e— A wol, J5 1; 0 L # WALLACE] N .2012 C"m 4 ;Ile, of CI%'".rr4 Niamiger WOO <16z- Y .4 9- nJl-;�*JN,ar.%, �0 � v-c L L 4 _Q>-T�ztz 6,'_Lic/c Property Appraiser - St.Lucie c-,,nty, FL Page 1 of 1 PROPERTY RECORD CARD Robert G Quick Record: 1 of 1 "Prev Next » Spec.Assmnt Taxes Exemptions Permits Home Print Property Identification ,��UCIE Cp Site Address: 318 SHADY LN ParcellD: 3419-510-0081-000-2 Secrrown/Range: 22 :36S :40E Account #: 41824 Map ID: Land Use: s SF Res Zoning: RS-4 RS-4 City/Cnty: St Lucie County �'•�. Ownership and Mailing Legal Description Owner: Robert G Quick Brenda I Quick RIVER PARK -UNIT 2- BLK 12 LOT 9 (MAP 34/22N) (OR 2678-2522) Address: 318 Shady Ln Port St Lucie FL 34952 Sales Information Assessment 2010 Final Total Land and Building Date Price Code Deed Book/Page 2010 Final: 87400 Land Value: 11100 Acres: 0.25 10/6/2006 210000 00 WD 2678 / 2522 Assessed: 87400 Building Value: 76300 10/6/2006 100 01 QC 2678 / 2520 Ag.Credit: 0 Finished Area: 1647 SgFt 8/18/2002 7000 00 WD 1572 / 2236 Exempt: 50000 9/27/1988 16000 05 WD 0610 / 0098 Taxable: 37400 Taxes: 981.75 BUILDING INFORMATION Lj Exterior Features View: RoofCover: SD - Dim Shingle RoofStruct: HP - Hip ExtType: HC+ - HC+ YearBlt: 2006 Frame: Grade: C+ - C+ EffYrBlt: 2006 PrimeWall: HP - Hardi Plank StoryHght: 0010 - 1 Story No.Units: 1 SecWall: Interior Features BedRooms: 3 Electric: MX - MAXIMUM PrmintWall: DW - Drywall FullBath: 2 HeatType: FHA - FrcdHotAir AvgHUFI: 1/2Bath: 0 HeatFuel: ELEC - Electric Prm.Flors: CU - Carpet %A/C: 100 %Heated: 100 %Sprinkled: 0 Special Features and Yard Items Land Information Type Y/S Qty. Units Qual. Cond. YrBlt. No. Land Use Type Measure Depth DWC - Driv-Concret Y 1 736 AV AV 2006 1 0100-SF Res 220 -Front Ft 85.5 125 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED http://www.paslc.org/prc.asp?prclid=341951000810002 6/8/2011 �. DRAINAGE DITCH CBS WALL N 33 °3G'GO" n ; n' rrr rr �— SET FD.-R71.R. JK 9 � � i�,� �j, I.R.C. OV 4942 .020' W &_0,50' N. NT `, I I n � �1 f I I MIN, SETBACK REQ. II 0 ^^'' FRONT �+ SIDES o 0 CNR SIDES — REAR ZNG. TECH. ,w LLOT 1 _AND IS SHOWN TOR TO VERIFY ALL AND ALL PROPOSED ONSTRUCTI ON. �3_ v�'- ,o."' 16.67 v z1 L DEL TA=15125'35" � R=222.85' L =50.00 FD. 3/4" I.P. SE 0.0.34' W W.M. Q` PA TIO 0 2.36' FRPOSED FAM,IL Y RESIDENCE 153/ Sara 0.f� 17.33' i i PORCH 0 0 18.67' . O t' t V) o rl _ 39PROPOSEDREA 1100sr.rT. + 39, I om 3 � 11 i 1 OT a F = i y 0'r s FD. 4942 1 1T.702 33'30'00" W. 10 . WEN L BEUX. MC SETS A STARDARD YARAER OF A W- IRON RVU AND A GAP dAMaD L9 $M AT ALL CVRMERS UNL'M 01PCJ WZ M07m . L ov TAD Cavo? 15 Voon AS . AND FIELD SURYE)W 001 rl-fo-o5 MW a" 6 E4MCSIANGLES 80MG Nr rlw7rp 1NE O� afA. • • AMr PFR RECaeo PLAT W �AADML O . WATER �. rMCI.LArM H POAE,T POLE D LJP. ® U7XJ7r PEMSTAL D) . am OR DESCAl nm 0 . NELL AM RW s CAP a Ll2T� LP.a • *ON PIPE i CAP o,C . PONr OF CVRVARAg L OaM L LEW PONT OF TANCMY ?RC. - POWT OF REYQSE pavA JtAB MWIT . NAL AAO A C/TA4 ?CC: . '.mr OF CO�o•raa® �•-�vAZR7E 01W AFW-C -WAY °.CP. P=�IAYE7/7 CJ/' PCMT Jp • WrE C:F.PAM�'EVT D./U.E . ~AW i/" UM/7Y EAS_N04, coNC . CO4CRE7E is - ELFCmTc TR4TL9'mAo cov. - commm AUF7J - &-CK MIC MS NOT DUARAAfffi CO ASSI&C ANY LWX,7Y FaR ANY EASEYENx MGMr-CF-WY. MIA= 1R'W'•'D`MA6 A==Xo.G S%" NA7TE7[S NOT SNONN OR RETERM TD ON TPE PAT.. OR PN'VrU ''Y KMZ oN SM DO SLMfY WAS PITEPAAEO MAfoV BEWRT OF AMRACT ITLE AND ALL NArE S OF 7771E 91CLo.0 je r�C RED O AN ATTO&VEr. US SLY7LEY IS NOT VAUD AITNWT IW SOIA.LR£ AND Dr- Q0G;NAL RAISW SAL Cr A fLORWA LJDE = SCPKXW AAfo YAPPM .fDLSD,-V&AI AWEAS NFRAWS AAV UhVV&?0 MD UT"Jl= 1F AMY MIT NOT JEe.'V LC. AIW. 0k7 RUN SNGNN. DRS SIMCY IS FOR THE USE CF TEA: PAR= SPECarCAUY CDT' 7M 70 ifr.+ M AND NC ZP.V D N.- LAST RFr71 "D DAM AUti:aMVW TO ME Fit' JE7. AL Y YANAWWNT A=CAWN (F&YA) PLOW W"ANCE RAM YAPS US PRoP_'R7Y LIES W FLOW ZOW X CLMWWrY PANS. ,/ CAM BA.x. iIEVA77OM N A BOUNDARY SURVEY rF'PTlcTcn rn; �i tl ROBERT BAUM CONSTRUCTION, IPJO. Ss_jR VE YaR'S CERTIFICA7YE I HEREBY CER77FY TO THE BEST OF MY BELIEF THAT THIS SURVEY IS TRUE AND ACCURA 7E AND THIS SUj?VEY MEElS THE MINIMUM TECHNICAL STANDARDS On SURVc'Y1NG AS PER CHAPTER 610i 7-o OF THE F.A.C. SUBJECT TO ALL NOTES AND NOTA77ONS _ w 11-20-03 L CMAjzLto7 Az>voL PsIn 1971 DAT' L 0 T 9, BL OCK 12, OF RIVER PARK UNIT 2 I 4C.COP,DING TO THE PLAT THEREOF, .4 S RECORDED IN PLAT BOOK 10 AT SAGE 72 OF THE PUBLIC Pr CORDS OE ST. LUCIE COUNTY, FLOR!D,4 REWSIONS i `nn sm- oI eAI �, r. ter. �� !r_ 1 �� q 0LJICK 318 5HAVY LANs~ 'RorZr SAwr Lvc tE ,FL Wx- I LM ' g' 11 Ri Sstoe cE) i ewq PoL4 &oF igivou- TO FRS 2'o/H FO4y Rco� EafF� 3 p2y $rcuu+Q� 1 was p� 5Fr' �L 1 Zx3 t� 2 �+t 3 14'6' r ISit14G E ; �Sgr->7 a n a C.0,A Totu,14 vX y rr.,Jop piSrS 2'a% 1 w 7 r �qu I a NxM g'rLax 10 x ri o L li It 1-7 Fll rYno-. . U77-�, , , gor-:� � xz z x z K 3 Sr,7rr Z.X 3 j q-I t" 3 f n y�:R7li.Fli�i�.l�lkiJLu.'! RED tE« ED FOR CO"( REV IEa;1(111 PLA IITiI,ST BE KEPT ON JOB' OR NO 3 4SPEs 1'I4\ NVII L BE NUDE. 1 14' FLASHING (CONT.) TUCK UNDER SHINGLED e LEAST b' (5) #14xW SNS V/ INTEGRAL 44' 0 KAX, WASAND NEOPRENE GASKET _ PER 12' VIDE PANEL. ED. SPACED (TYP.) (RISER PANS) SECURE FASCIA TO EACH RAFTER TAIL (OR) SEALANT W/ (D WO x 4' LONG PAN HEAD LAG SCREWS 01406�WAS14I SN V/ INTEGRAL BEFORE ATTACHING RECEIVING CHANNEL WASHER AND NEOPRENE GASKET SKE EXTRUDED OR BRAKE -FORMED ROOF HE e 12' D.C. TOP 6 BOTTOM. DR RECEIVING CHANNEL (Q044' NBN. T KNESS) <LDHPUSITE ROOF) WITH MIN. IW BEARING LEG SLOPE (1) WO x 2' LAG SCREW a 24' D.C. ENTIRE LENGTH OF RECEIVING CHANNEL O0p0000°0 ° 0 0 0 0 �SO'FIT 0 //o°o°o°o°0 (1 LB EPS) ITE PANEL .J LA #IOx4' S.MS. V/ IWO FENDER VAS - - - - .,-_'. AND NEOPRENE GASKET a I2' 3' Cf#1P01 ROOF PANEL, ,E o°o°o°o°oT o°o°o°o°o°oc0 0 0 0 0 0 0 0 0 0�00 0 0 o�o_zo EDGE BEAM (SEE PLAN FOR SIZE) (6) 114x14' S.MS.. (3) SCREWS I I EACH LEG (TYP.) I 1:1X%- BY 3' LONG ANGLE i COLUMN/POST I I (TYP. EACH SIDE) (SEE PLAN FOR SEM I 1 i I COMPOSITE ROOF TO HOLLOW EDGE BEAM CONNECTION DETAIL #lDx4- S.N.S. V/ IWO H WASHER AND NEOPRENE e is, D.C. ;O;O8 808080808080 O°O° °O°O°O°O°O°O SIDE WALL HEADER � w1DTH1A� (SEE PLAN FOR SIZE) I (T\P. EABY CH ' LONG ANGLE EACH LEG i ! LEG (TYP) .. (3) SCREWS I 1 I I COLUMN/POST (SEE PLAN FUR SIZE) I I 1 SITE ROOF TO HOLLOW SIDE WALL HEADER/ CONNECTION DETAIL 4'0124 ' LAG SCREW O 12' O.0 (1) WITHIN 3' OF EDGES C".) 1'12- O.B. C".) NOTE' STUD FOR BLOCK FRAMED HOUSES USE /14x2Y' CONCRETE SCREW WOOD FRAME WALL O 18' O.C.. 1 WITHIN 3• OF EDGES (TYP.) TYPICAL SCREEN EDGE TO STRUCTURE CONNECTION DETAIL 2x5x)V ANGLE (2' LONG) V/ (2)-814 TEKS INTO TOP OF 2.3 EAVE RAIL AND (2>- #14 TEKS INTO THE FRONT OF THE 3x3 CORNER POST L-1 x2 O.B. TOP FRAME 1x3 O.B. FASTENED TO CORNER CORNER P13ST SECTION WITH #1012- S.M.s. W/ %' DIALWASHERO 18' O.C. 1x3 O.B. SIDE WALL CORNER UPRIGHT ELEVATION VIEW CORNER POST / COLUMN . UPRIGHT DETAIL FOR SIZE ix 0.8'. ED TO CORNER SE WITH /141I S.M.S.( 24' ANGLE Y LONG (EACH #14A4 S.Y.S. TO POS "0 H.D. GALV. EXP. SOL 1/2- MIN. EMBEDMENT POST / COLUMN TO FOUNDAT CONNECTION DETAIL 1.IW BY 3' LONG - ANGLE. EACH SIDE (TYP.) (4) /14x14' S.M.S.. 2 SCREWS - EACH LEG (TYP.) CHAIR RAIL / GIRT TO POST CONNECTION DETAIL 3 v )NG BOSSES General Notes and Specifications: 1. Contractor shall field verify all dimensions before construction and shall notify engineer of discrepancies for immediate consideration. 2. Concrete shall be minimum 28 day compressive strength of f'c=2500 psi, and be in accordance with the requirements of ACI 31a Reinforcing steel shall have a min. yield strength of 40,000 psi (grade 40) and be provided with cover in accordance with AO 318. 3. All dimensions are provided by contractor, Do Kim & Associates, LLC have made interpretations where necessary. 4. The following structures are designed to be attached to block and wood frame structures of adequate structural capacity. The contractor shall verify that the host structure is in good condition and of sufficient strength to hold the proposed addition If there is a question about the host structure, the owner (at his own expense) shall hire an arcNtect or engineer to verify host structure capacity. 5. Connections using screw bosses shall have minimum (4)-#10x7' per connection unless shown otherwise. 6. Unless otherwise shown, screws shall Have minimum edqe distance and center -to -center distances as shown in this table. C-1022 Low Carbon Steel SMS & Self -Drilling (TEK) Screws (Industry Standard Screws) Screw Nominal Screw Diameter (in) hlinimum Edge Distance Minimum Center to Center Distance #10 0.188 #12 0.219 #14 (1/4") 0.250 Y2" s/,' 7. Structure has been designed to meet the 2007 FBC with 2009 Supplement. Project is sited where the basic wind speed is 140 mph (3-sec gust). 1=0.77 for screen enclosures. Exposure B. 8. All concrete anchors shall be Simpson Strong -Tie Wedge All Anchors or Titian Screws or approved equal. 9. All aluminum components shall be 6005-T5 Alloy. Aluminum roof panels shall be of aluminum alloy 3105-H5 or 3105-H25. s 4" NOMINAL CONCRETE SLAB POST W?W M. OR FIBER REINFORCEDO [POLYPROPYLENE FIBER - 1.5 POUND (MIN.)PER C.Y.] ^ a Z H .. CO — a Z � ,4• v `e APPROXIMATE ; ...- GRADE �--� `UNDISTURBED SOIL OR COMPACTED CRUSHED LIMERDCK (90% PROCTOR) #5 REBAR CONTINUOUS, SPLICE UST OVERLAP 20' MIN. 3' COVER (TYP.) THICKENED EDGE SLAB/POST DETAIL DO KIM I & ASSOCIATES, LLC CONSULTING STRUCTURAL ENGINEERS PO BOX 10039 Tampa, FL 33679 Tel: (813) 374-0321 Fax: (813) 374-0322 I !�, 12 11 I ISSUED 0 M J W 0 W U O o U U O a)) a IL U F_ O C: Z W U C Z U U W W a U 0 DRAWN BY: DYK CHECKED BY: DYK SCALE: AS SHOWN DATE: 327/O6 DO YEO P.E. FLA. `RX UMB R 49497 DO Kl SSO IATES, LLC A# 2 87 P BOX Tampa, FL 33679 ti' C/ Drawing No. - 060327 SHEET 10F1