HomeMy WebLinkAboutSUBMITTED PAPERSOFFICE
1
2
3
4
Y:
PLANNING & DEVELOPMENT SERVICES
s BUILDING & CODE REGULATION DIVISION
2300 Virginia Avenue n ,
Ft. Pierce, FL 34982-5652
772-462-1553
APPLICATION FOR ALUMINUM STRUCTURES PERMIT
ALL INFO MUST BE COMPLETE & FILLED IN TO BE EPTED
PROJECT INFORMATION
LOCATION/SITE ADDRESS: 318 Shady Ln Port Saint Lucie. FL 34
PROJECT NAME: Quick SITE PLAN N E:
PROPERTY TAX ID #: 3419-510-0081-000-2
LEGAL DESCRIPTION (attach extra sheets if necessary):
River Park - Unit 2 - Lot9- Blk 12
St. Lucie County
5. PLAT BK 10 PAGE rIZ BLOCK 12 LOT 1
6. PARCEL SIZE: ACRES/SQ FT. ,_L LOT DIMENSIONS 2 e Q �
1
7. SETBACKS (ACTUAL) FRONT: BACK: 35�I s RIGHT SIDE: 7,Ce LEFT SIDE:
8. TYPE OF STRUCTURE (CHECK ALL APPROPRIATE BOXES FOR EACH6N,[%jVERY TYPE OF STRUCTURE)
Y
'TYPE OF CONSTRUCTION
N = New
A = Addition
R = Rebuild
SG = Slab on Grad(10
SR = Raised Slab �
WD = Wood Deck
DIMENSIONS
SQUARE FEET OF
CONSTRUCTION
IXI
SCREEN ROOM
N
S6 NEW
EXISTI G
X
®
CARPORT/PATIO ROOF
N
SG ,E NEW
EXISTING
10 X
370
❑
HABITABLE GLASS ROOM
❑ NEW
❑
EXISTING
X
❑
CAT 1, 2 OR 3 SUNROOM
❑ NEW
❑
EXISTING
X
❑
ALUMINUM COMP. SHED
❑ NEW
❑
EXISTING
X
❑
POOL ENCLOSURE
❑ NEW
❑
EXISTING
X
❑
M H ROOF OVER
❑ NEW
❑
EXISTING
X
❑ ROOF SYSTEM OVER
EXISTING ACCESSORY STRUCTURE
❑ NEW
❑
EXISTING
X
❑
OTHER:
❑ NEW
❑
EXISTING
X
❑
ALUM POOL FENCE
Linear tcet
TOTAL SQUARE FOOTAGE OF CONSTRUCTION
9. VALUE OF CONSTRUCTION: $ 5,625.00
The value of construction is used to determine the amount of permit fees to be assessed. St. Lucie County reserves the right to
question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with
similar types of construction activities. If the value is $2500 or more, a RECORDED Notice of Commencement must be submitted
PRIOR TO FIRST INSPECTION.
SLCCDV Form No.: 001-02 ReK04126/2010
OWNER INFORMATION
NAME: Robert & Brenda Quick
ADDRESS: 318 Shady Lane Port Saint Lucie, FL 34952
CITY: Port Saint Lucie STATE: FL ZIP 34952
PHONE (DAYTIME): (77ZJ 828-1450 EMAIL:
FILL IN NAME AND ADDRESS BELOW IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM
THE OWNER LISTED ABOVE:
FEE SIMPLE TITLEHOLDER:
ADDRESS:
CITY: STATE: ZIP
PHONE (DAYTIME): ( )
CONTRACTOR INFORMATION
STATE OF FLORIDA REG./CERT #: RX 1 1 0 6 6 91 9 ST. LUCIE COUNTY CERT #: 4763
BUSINESS NAME: Pioneer Screen Co. Inc. II
QUALIFIER'S NAME: Michael Newman
ADDRESS: 1682 SW Biltmore St
Port Saint Lucie FL 34984
CITY: STATE: ZIP
PHONE (DAYTIME): 772 )340-4393 FAXNO.772-340-4626 email: pioneerscreen@msn. co
ARCHITECT/ENGINEER: Do Kim & Associates
ADDRESS: PO BOX 1003
CITY: Tampa STATE: FL ZIP 33679
PHONE (DAYTIME): 33) 857-9955
NOTE: IF APPLICABLE, SUBCONTRACTOR AGREEMENTS MUST BE ATTACHED TO APPLICATION FOR ROOFING, ELECTRIC, PLUMBING,
AND HVAC
ZONING REQUIREMENTS
All such structures will be subject to the requirements of the ST. LUCIE COUNTY LAND DEVELOPMENT CODE.
❑ 2 scaled plot plans showing lot size, dimensions of existing host structure, and proposed aluminum addition. All setbacks
including front, side, rear and distance between adjacent property structures in MH Parks shall be indicated on the plot plan.
❑ 2 sets of color photos for all storm damaged areas to be reconstructed. One picture must include house address number for
inspection verification. ( not required for construction unrelated to storms)
OFFICE USE ONLY
SECTION
� rl
�,p�
TOWNSHIP
RANGE
1
"'1,�
MAP NO.
�n /
' V
Additional
ZONING
1 '
LAND USE
(�
`I
LOT CVG %
`� t
1/ `14
Permits
"�
Required
REPORT
L�
BIMS FEE
$
MISC FEES
$
TOTAL FEES
$
CODE
BUILDING & ZONING REVIEW
FRONT
PLANS
VALL II: OF CONSIRI ACTION
REVIEW
COUNTER
ZONING
SUPERVISOR
EXAMINER
VEGET TION
USING ICC TLABLE�j
DATE
COMPLETE
i
� ��
X � A% '
INITIALS
CERTIFICATION:
This application is hereby made in order to obtain a permit to do the work and installations as indicated, and to obtain a
certificate of capacity, if applicable, for the permitted work.
NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO
OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT.
NOTICE TO APPLICANT: IN THE EVENT IT IS NOT YOUR RIGHT TITLE OR INTEREST THAT IS SUBJECT TO
ATTACHMENT, THE APPLICANT DOES HEREBY MAKE A GOOD FAITH PROMISE TO
DELIVER A COPY OF THE ATTACHED CONSTRUCTION LIEN LAW NOTICE TO THE
PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT, AND DOES SO AS A
CONDITION PRECEDENT TO THIS PERMIT
1. If utilizing the AAF Guide to Aluminum Construction in High Wind Zones, I the Contractor/Owner Builder hereby certify
that the components being used, fasteners type and fastening pattern meet all the requirements for the designated wind
zones established by the county and take full responsibility for complying with the submitted design of the structure being
permitted.
2. I further certify that all the foregoing information is accurate, that no work or installation has commenced prior to the
issuance of a permit and that all work shall be performed in compliance with all applicable laws regulating construction and
zoning in this jurisdiction. 1 understand that separate permits may be required for ELECTRICAL, and HVAC, etc., not
otherwise included with this building permit application.
3. 1 , the Contractor / Owner B ' er, have verified that the existing foundation 8eets the requirements of the Engineer of
Record and ' n adequate c ion to withstand the uplift and weight -of the a mum structure said structure will not
exceed the print of the r cture that was in existence prior t 6mova1 by storms.
OR CONTRACTU SIGNATURE
STATE OF FLORIDA
COUNTY OF '+, L "c <_
The foregoing instrument was acknowledged before me
me this day of ; U,rt , 20 it ,
by M i C "a e% dC ►,J ma.n
who is personally known V_ to me, or who has
produced
as ide tification.
Signature of Notary
IMPORTANT NOTICES:
STATE OF FLORIDA
COUNTY OF SA--. L_L c- i .{
The foregoing instrument was acknowledged before me
hd
me this
�^2- day of ltsr+t , 20 11
by �e_LJYY-Nar,
who is personally known ---%,,t6me. or who has
produced
as
"OtRLY S WALLAM
MY COMMISSION # DD�M*
Rf EXPIRES November 03, 2012
1'` FloridallotarvService.com
511VI RLY S W4LLACE
`1y COMMISSION # D835305
i"XPIRES Novembef, 03, 2012
• TWO (2) SIGNATURES AZFE REQUIRED. EACH SIGNATURE MUST BE NOTARIZED7r7XPPL:YINl5T0 t'r"
BUILDING PERMIT AS AN OWNER/BUILDER, THE OWNER MUST PERSONALLY APPEAR, IN THE OFFICE
LISTED ON THE FRONT OF THE APPLICATION, TO SIGN THIS APPLICATION & THE OWNER/BLDR
AFFIDAVIT.
• ALL SIGNATURES ON APPLICATION SUBMITTED SHALL BE ORIGINAL, SIGNED IN INK. COPIES, FAXES, OR
STAMPED REPRODUCTIONS ARE PROHIBITED.
• WHEN A PERMIT IS AVAILIBLE FOR ISSUANCE BUT IS NOT PICKED UP WITHIN THIRTY (30) DAYS AFTER
NOTIFICATION OF AVAILIBILITY, IT WILL BE VOIDED. IF THE APPLICATION IS RESUBMITTED, AN
ADDITIONAL FEE WILL BE CHARGED.
PLAN REVIEW SPECIFICATION CHECKLIST
PLEASE PROVIDE ONE OF THE FOLLOWING:
❑ 2 Sets of Detailed Plans: Dated, Signed & Sealed by an Engineer or Architect holding a Florida State professional license.
❑ 2 Sets of Detailed Plans: Designed in accordance with the AAF Guide to Aluminum Construction in High Wind Areas.
❑ 2 Sets of Detailed Plans: Designed in accordance with any Approved Manual per fs-489.113.
(I) ANY PLANS SUBMITTED WITHOUT COMPLYING WITH THE FOLLOWING SHALL BE RETURNED WITHOUT
APPROVAL. ALL PLANS MUST BE IN INK AND ANY NOTATIONS IN PENCIL WILL NOT BE CONSIDERED A PART OF
A SUBMISSION.
• All plans must be legible and must be designed in Architect's Scale on pages which are 81/2" x I I" or larger.
• All relevant tables & details, if using a manual, must be properly highlighted and must match design checklists &
drawings.
• The plan view must include all dimensions; the location of the host structure and all materials must be sized and
identified thereon.
• All elevations must be shown, including 4`h wall detail, dimensions and all material must be sized and identified.
• All primary and secondary carrier beams, spans, spacing, gauges must be shown [Example: 2" x 8" x .072"].
• All methods of fastening or other details which are relevant to the design must be identified on the Plans.
• All upright column heights, sizes, spacing and gauges must be shown as follows: [Example: 3" x 3" x .050"].
• All chair -rails, roof purlins, girts, channels, knee -bracing, k-bracing, cable bracing or any other required component
must be sized and identified.
• All ridge beams and super gutter or fascia attachments must be identified.
• All roof pans or composite panels, with gauges and spans, must be sized and identified.
• All footing, slab and ISO pier designs must be on the plans, per the Architect / Engineer's plans & specifications.
• All light metal alloys which are utilized shall be designed in conformity with the Florida Building Code of 2007, Chapter
20, including 2006 revisions.
• Barrier railings, if utilized, shall have all materials, fasteners and height specified and shall have self -closing, self -
catching gates with picket spacing.
(II) SITE CONSTRUCTED SHEDS, HAVING ANY ALUMINUM COMPONENT, SHALL MEET ALL OF THE ABOVE
REQUIREMENTS AND THE FOLLOWING ADDITIONAL ITEMS:
(A) 2 copies of the current product approval [i.e. N.O.A. or State of Florida approval] with the proposed "opening" or cladding
component highlighted and with fasteners and design pressures, per FBC 1714, clearly identified.
(B) 2 electric schematics, in accordance with the N.E.C., if applicable.
(C) Design pressures, per ASCE-7, identified on the openings of all Plans.
(III) HABITABLE ROOMS/ADDITIONS DESIGNS SHALL MEET ALL OF THE ABOVE REQUIREMENTS, EXCEPT AAMA
SPECIFICATIONS, AND CHAPTER 13 OF THE FLORIDA BUILDING CODE.
(IV) SUNROOMS (as defined in R202 and FBC 2002.6) MAY BE CONSTRUCTED, SO LONG AS THEY MEET ALL OF THE
ABOVE REQUIREMENTS AND MUST BE IN STRICT COMPLIANCE WITH AAMA/NPEA/NSA2100.02 AND MEET THE
FOLLOWING ADDITIONAL ITEMS:
(1) The designer or engineer will state on all Plans, which Category of Design [3.1.2] will be used, inclusive of the definition.
(2) If designing a Category 4 or Category 5 structure, as defined in the current Edition of 3.1.2.4 and 3.1.2.5, proper energy
calculations and long form equipment sizing calculations shall be required, pursuant to Chapter 13 of the current State of
Florida Building Code.
(V) MOBILE HOMES (FAC 15C-2.0081 - FAC 15C-2.0072): ALL STRUCTURES ADJACENT TO OR NEW ROOF SYSTEMS
(Pan or Composite) OVER EXISTING ADJACENT STRUCTURES TO A MOBILE HOME SHALL REQUIRE:
(a) A 4"' wall or a current, signed original manufacturer's attachment approval letter which includes the model number, serial
number and current owner's name and street address.
(b) That the complete guide to H.U.D. specifications be strictly adhered to.
(c) A Certified Florida Engineer may design the manner of attachment of the proposed structure to the host house but shall
assume full responsibility for both structures' integrity by site specific documentation.
06/13/2011 09:41 3404626
Pioneer sCre-'eri'C"o". 1,3c.
1682 SW BiltIftore St
Port Saint Lucie, Fl. 34984
F 0; 7 0, t
A C�
THE CIRCUIT COURT
SAINT LUcIE C O-rH CULL *SEPHE'SM' j,� —
f9LE* 359016006108/2011 8110- AMOR &)OK 3299 PAGE 1819 - 18'46
RECORDING: 510,00 '9 DOc TYPe: NC
PAGE 01
CIP p A, Rrjp
i 341
81 t )Ck C
C?
E� RAL DES(- kRTION'OE 00`R0VEWRVr': Ins+Zallation
�f n
-CS
14,
ad,4-,C4� C'r jr py,
"1 4;�j, r t,
TRAf "TO K"s'SAME Atkk5 AND pp
-sF
1682 sw Pioneer scTeen 0.
r i! S t Port
1.2 NA'4Z. ADEIRL&Sks,�L, FH4-.
DMS
ntr Upi.in -.3
Wr-r:j A7�
1'. jj)p RF i.
hND Pw()*4'F
!xlc! 4, t .11
U -or
k Y:E. mq�jjfss -OiD PRON't!YIN.gD� wal
'A7
A:-n. zh?fr., "Ift law c;•', My,;
.!;-,a Unless. a ;jffrc:j;
PH"( Nal"C'mad pro-lide Impsts", -
Rorida
e—
A wol,
J5
1;
0 L
#
WALLACE]
N .2012
C"m
4 ;Ile,
of CI%'".rr4
Niamiger WOO
<16z-
Y .4 9-
nJl-;�*JN,ar.%,
�0 � v-c L L 4 _Q>-T�ztz 6,'_Lic/c
Property Appraiser - St.Lucie c-,,nty, FL
Page 1 of 1
PROPERTY RECORD CARD
Robert G Quick
Record: 1 of 1
"Prev Next » Spec.Assmnt Taxes Exemptions Permits Home Print
Property Identification
,��UCIE Cp
Site Address:
318 SHADY LN
ParcellD:
3419-510-0081-000-2
Secrrown/Range:
22 :36S :40E
Account #: 41824
Map ID:
Land Use:
s
SF Res
Zoning:
RS-4
RS-4
City/Cnty:
St Lucie County �'•�.
Ownership and Mailing
Legal Description
Owner:
Robert G Quick
Brenda I Quick
RIVER PARK -UNIT 2- BLK 12 LOT 9 (MAP 34/22N) (OR 2678-2522)
Address:
318 Shady Ln
Port St Lucie FL 34952
Sales Information
Assessment 2010 Final Total Land and Building
Date Price Code
Deed
Book/Page
2010 Final: 87400 Land Value: 11100 Acres: 0.25
10/6/2006
210000 00
WD
2678 / 2522
Assessed: 87400 Building Value: 76300
10/6/2006
100 01
QC
2678 / 2520
Ag.Credit: 0 Finished Area: 1647 SgFt
8/18/2002
7000 00
WD
1572 / 2236
Exempt: 50000
9/27/1988
16000 05
WD
0610 / 0098
Taxable: 37400
Taxes: 981.75
BUILDING INFORMATION
Lj
Exterior Features
View:
RoofCover:
SD - Dim Shingle
RoofStruct:
HP - Hip
ExtType:
HC+ - HC+
YearBlt:
2006
Frame:
Grade:
C+ - C+
EffYrBlt:
2006
PrimeWall:
HP - Hardi Plank
StoryHght:
0010 - 1 Story
No.Units:
1
SecWall:
Interior Features
BedRooms:
3
Electric:
MX - MAXIMUM
PrmintWall:
DW - Drywall
FullBath:
2
HeatType:
FHA - FrcdHotAir
AvgHUFI:
1/2Bath:
0
HeatFuel:
ELEC - Electric
Prm.Flors:
CU - Carpet
%A/C:
100
%Heated:
100
%Sprinkled:
0
Special Features and
Yard Items
Land Information
Type
Y/S Qty. Units
Qual. Cond.
YrBlt. No. Land Use
Type
Measure Depth
DWC - Driv-Concret
Y 1 736
AV AV
2006 1 0100-SF Res
220 -Front Ft
85.5 125
THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED
http://www.paslc.org/prc.asp?prclid=341951000810002 6/8/2011
�. DRAINAGE DITCH
CBS WALL
N 33 °3G'GO" n ; n'
rrr rr
�— SET
FD.-R71.R. JK
9 � � i�,� �j, I.R.C. OV 4942
.020' W &_0,50' N.
NT `, I
I
n �
�1
f
I I MIN, SETBACK REQ. II 0 ^^''
FRONT �+
SIDES o
0
CNR SIDES —
REAR
ZNG.
TECH.
,w
LLOT 1
_AND IS SHOWN
TOR TO VERIFY ALL
AND ALL PROPOSED
ONSTRUCTI ON.
�3_
v�'- ,o."' 16.67
v
z1
L
DEL TA=15125'35" �
R=222.85'
L =50.00
FD. 3/4" I.P.
SE
0.0.34'
W
W.M. Q`
PA TIO
0
2.36'
FRPOSED
FAM,IL Y
RESIDENCE
153/ Sara 0.f�
17.33'
i i PORCH
0
0
18.67' .
O t'
t V)
o rl
_ 39PROPOSEDREA 1100sr.rT. +
39, I
om
3 �
11
i
1 OT a
F = i y 0'r
s
FD.
4942 1 1T.702
33'30'00" W.
10 .
WEN L BEUX. MC SETS A STARDARD YARAER OF A W- IRON RVU AND A GAP
dAMaD L9 $M AT ALL CVRMERS UNL'M 01PCJ WZ M07m . L ov
TAD Cavo? 15 Voon AS . AND FIELD SURYE)W 001 rl-fo-o5
MW a" 6 E4MCSIANGLES 80MG Nr rlw7rp
1NE O� afA. • • AMr PFR RECaeo PLAT
W �AADML O . WATER �. rMCI.LArM H POAE,T POLE
D LJP. ® U7XJ7r PEMSTAL
D) . am OR DESCAl nm 0 . NELL
AM RW s CAP a Ll2T�
LP.a • *ON PIPE i CAP
o,C . PONr OF CVRVARAg L OaM
L LEW
PONT OF TANCMY
?RC. - POWT OF REYQSE pavA JtAB MWIT . NAL AAO A C/TA4
?CC: . '.mr OF CO�o•raa® �•-�vAZR7E 01W AFW-C -WAY
°.CP. P=�IAYE7/7 CJ/' PCMT Jp • WrE C:F.PAM�'EVT
D./U.E . ~AW i/" UM/7Y EAS_N04, coNC . CO4CRE7E
is - ELFCmTc TR4TL9'mAo cov. - commm
AUF7J - &-CK MIC MS NOT DUARAAfffi CO ASSI&C ANY LWX,7Y FaR ANY
EASEYENx MGMr-CF-WY. MIA= 1R'W'•'D`MA6 A==Xo.G
S%" NA7TE7[S NOT SNONN OR RETERM TD ON TPE PAT.. OR PN'VrU ''Y
KMZ oN SM DO SLMfY WAS PITEPAAEO MAfoV BEWRT OF AMRACT
ITLE AND ALL NArE S OF 7771E 91CLo.0 je r�C RED O AN ATTO&VEr.
US SLY7LEY IS NOT VAUD AITNWT IW SOIA.LR£ AND Dr- Q0G;NAL RAISW
SAL Cr A fLORWA LJDE = SCPKXW AAfo YAPPM
.fDLSD,-V&AI AWEAS NFRAWS AAV UhVV&?0 MD UT"Jl= 1F AMY MIT
NOT JEe.'V LC. AIW. 0k7 RUN SNGNN.
DRS SIMCY IS FOR THE USE CF TEA: PAR= SPECarCAUY CDT' 7M 70
ifr.+ M AND NC ZP.V D N.- LAST RFr71 "D DAM
AUti:aMVW TO ME Fit' JE7. AL Y YANAWWNT A=CAWN (F&YA)
PLOW W"ANCE RAM YAPS US PRoP_'R7Y LIES W FLOW ZOW X
CLMWWrY PANS. ,/ CAM
BA.x. iIEVA77OM N A
BOUNDARY SURVEY
rF'PTlcTcn rn;
�i
tl
ROBERT BAUM CONSTRUCTION, IPJO.
Ss_jR VE YaR'S CERTIFICA7YE
I HEREBY CER77FY TO THE BEST OF MY BELIEF THAT
THIS SURVEY IS TRUE AND ACCURA 7E AND THIS
SUj?VEY MEElS THE MINIMUM TECHNICAL STANDARDS
On SURVc'Y1NG AS PER CHAPTER 610i 7-o OF THE
F.A.C. SUBJECT TO ALL NOTES AND NOTA77ONS
_ w
11-20-03
L CMAjzLto7 Az>voL PsIn 1971 DAT'
L 0 T 9, BL OCK 12, OF
RIVER PARK UNIT 2 I
4C.COP,DING TO THE PLAT THEREOF,
.4 S RECORDED IN PLAT BOOK 10 AT
SAGE 72 OF THE PUBLIC Pr CORDS
OE ST. LUCIE COUNTY, FLOR!D,4
REWSIONS
i `nn sm- oI eAI �, r. ter. �� !r_ 1 �� q
0LJICK
318 5HAVY LANs~
'RorZr SAwr Lvc tE ,FL
Wx-
I LM ' g'
11
Ri Sstoe cE)
i ewq PoL4 &oF igivou- TO FRS
2'o/H
FO4y Rco�
EafF� 3 p2y $rcuu+Q�
1 was p� 5Fr'
�L
1
Zx3
t�
2
�+t 3
14'6'
r ISit14G
E ; �Sgr->7
a n
a C.0,A Totu,14
vX y rr.,Jop piSrS
2'a%
1
w
7
r �qu I a NxM
g'rLax 10 x ri o
L
li
It
1-7
Fll rYno-.
. U77-�, , ,
gor-:�
� xz
z
x
z
K
3 Sr,7rr
Z.X 3
j
q-I t"
3
f n y�:R7li.Fli�i�.l�lkiJLu.'!
RED tE« ED FOR CO"(
REV IEa;1(111
PLA IITiI,ST BE KEPT ON JOB'
OR NO 3 4SPEs 1'I4\ NVII L BE NUDE. 1
14' FLASHING (CONT.)
TUCK UNDER SHINGLED
e LEAST b'
(5) #14xW SNS V/ INTEGRAL 44' 0 KAX,
WASAND NEOPRENE GASKET
_
PER 12' VIDE PANEL. ED. SPACED (TYP.)
(RISER PANS)
SECURE FASCIA TO EACH RAFTER TAIL
(OR) SEALANT
W/ (D WO x 4' LONG PAN HEAD LAG SCREWS
01406�WAS14I SN V/ INTEGRAL
BEFORE ATTACHING RECEIVING CHANNEL
WASHER AND NEOPRENE GASKET
SKE
EXTRUDED OR BRAKE -FORMED ROOF HE
e 12' D.C. TOP 6 BOTTOM.
DR RECEIVING CHANNEL (Q044' NBN. T KNESS)
<LDHPUSITE ROOF)
WITH MIN. IW BEARING LEG
SLOPE
(1) WO x 2' LAG SCREW a 24' D.C.
ENTIRE LENGTH OF RECEIVING CHANNEL
O0p0000°0 °
0 0 0 0
�SO'FIT
0
//o°o°o°o°0
(1 LB EPS)
ITE PANEL .J LA
#IOx4' S.MS. V/ IWO FENDER VAS - - - - .,-_'.
AND NEOPRENE GASKET a I2' 3' Cf#1P01
ROOF PANEL,
,E
o°o°o°o°oT
o°o°o°o°o°oc0 0 0 0 0 0 0 0 0 0�00 0 0 o�o_zo
EDGE BEAM
(SEE PLAN FOR SIZE)
(6) 114x14' S.MS.. (3) SCREWS
I I EACH LEG (TYP.)
I
1:1X%- BY 3' LONG ANGLE
i
COLUMN/POST I I (TYP. EACH SIDE)
(SEE PLAN FOR SEM I 1
i
I
COMPOSITE ROOF TO HOLLOW EDGE BEAM
CONNECTION DETAIL
#lDx4- S.N.S. V/ IWO H
WASHER AND NEOPRENE
e is, D.C.
;O;O8 808080808080
O°O° °O°O°O°O°O°O
SIDE WALL HEADER � w1DTH1A�
(SEE PLAN FOR SIZE) I
(T\P. EABY CH ' LONG
ANGLE EACH
LEG i ! LEG (TYP) .. (3) SCREWS
I 1
I I COLUMN/POST
(SEE PLAN FUR SIZE)
I I
1
SITE ROOF TO HOLLOW SIDE WALL HEADER/
CONNECTION DETAIL
4'0124
' LAG SCREW O 12' O.0
(1) WITHIN 3' OF EDGES C".)
1'12- O.B. C".)
NOTE' STUD
FOR BLOCK FRAMED HOUSES USE
/14x2Y' CONCRETE SCREW WOOD FRAME WALL
O 18' O.C.. 1 WITHIN 3•
OF EDGES (TYP.)
TYPICAL SCREEN EDGE TO STRUCTURE
CONNECTION DETAIL
2x5x)V ANGLE (2' LONG) V/ (2)-814
TEKS INTO TOP OF 2.3 EAVE RAIL AND (2>-
#14 TEKS INTO THE FRONT OF THE 3x3 CORNER POST
L-1 x2 O.B. TOP FRAME
1x3 O.B. FASTENED TO CORNER CORNER P13ST
SECTION WITH #1012- S.M.s. W/
%' DIALWASHERO 18' O.C.
1x3 O.B. SIDE WALL CORNER UPRIGHT
ELEVATION VIEW
CORNER POST / COLUMN .
UPRIGHT DETAIL
FOR SIZE
ix 0.8'. ED TO CORNER
SE WITH
/141I S.M.S.(
24'
ANGLE Y LONG (EACH
#14A4 S.Y.S. TO POS
"0 H.D. GALV. EXP. SOL
1/2- MIN. EMBEDMENT
POST / COLUMN TO FOUNDAT
CONNECTION DETAIL
1.IW BY 3' LONG -
ANGLE. EACH SIDE (TYP.)
(4) /14x14' S.M.S..
2 SCREWS -
EACH LEG (TYP.)
CHAIR RAIL / GIRT TO POST
CONNECTION DETAIL
3
v
)NG
BOSSES
General Notes and Specifications:
1. Contractor shall field verify all dimensions before construction and shall notify engineer of discrepancies for immediate
consideration.
2. Concrete shall be minimum 28 day compressive strength of f'c=2500 psi, and be in accordance with the requirements of ACI 31a
Reinforcing steel shall have a min. yield strength of 40,000 psi (grade 40) and be provided with cover in accordance with AO 318.
3. All dimensions are provided by contractor, Do Kim & Associates, LLC have made interpretations where necessary.
4. The following structures are designed to be attached to block and wood frame structures of adequate structural capacity. The
contractor shall verify that the host structure is in good condition and of sufficient strength to hold the proposed addition If
there is a question about the host structure, the owner (at his own expense) shall hire an arcNtect or engineer to verify host
structure capacity.
5. Connections using screw bosses shall have minimum (4)-#10x7' per connection unless shown otherwise.
6. Unless otherwise shown, screws shall Have minimum edqe distance and center -to -center distances as shown in this table.
C-1022 Low Carbon Steel SMS & Self -Drilling (TEK) Screws (Industry Standard Screws)
Screw
Nominal Screw Diameter
(in)
hlinimum Edge Distance
Minimum Center to Center
Distance
#10
0.188
#12
0.219
#14 (1/4")
0.250
Y2"
s/,'
7. Structure has been designed to meet the 2007 FBC with 2009 Supplement. Project is sited where the basic wind speed is 140 mph
(3-sec gust). 1=0.77 for screen enclosures. Exposure B.
8. All concrete anchors shall be Simpson Strong -Tie Wedge All Anchors or Titian Screws or approved equal.
9. All aluminum components shall be 6005-T5 Alloy. Aluminum roof panels shall be of aluminum alloy 3105-H5 or 3105-H25.
s
4" NOMINAL CONCRETE SLAB
POST W?W M. OR FIBER REINFORCEDO
[POLYPROPYLENE FIBER - 1.5
POUND (MIN.)PER C.Y.]
^ a Z
H
.. CO —
a Z �
,4•
v `e
APPROXIMATE ; ...-
GRADE �--�
`UNDISTURBED SOIL OR COMPACTED
CRUSHED LIMERDCK (90% PROCTOR)
#5 REBAR CONTINUOUS, SPLICE
UST OVERLAP 20' MIN.
3' COVER (TYP.)
THICKENED EDGE
SLAB/POST DETAIL
DO KIM I
& ASSOCIATES, LLC
CONSULTING
STRUCTURAL
ENGINEERS
PO BOX 10039
Tampa, FL 33679
Tel: (813) 374-0321
Fax: (813) 374-0322
I !�, 12 11 I ISSUED
0
M
J
W
0
W
U
O
o
U
U
O
a))
a
IL
U
F_
O
C:
Z
W
U
C
Z
U
U
W
W
a
U
0
DRAWN BY:
DYK
CHECKED BY:
DYK
SCALE:
AS SHOWN
DATE:
327/O6
DO YEO P.E.
FLA. `RX UMB R 49497
DO Kl SSO IATES, LLC
A# 2 87
P BOX
Tampa, FL 33679
ti'
C/
Drawing No. - 060327