Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SUBMITTED PAPERS
DATE FILED:' �� PLAN REVIEW FEE _ RECEIPTNO.: CONCURRENCY FEE: RECEIPT NO.: PERMIT NUMBER: CERT. CAP. NO.: I0(0- a 1 [-�) ALL INFO MUST BE COMPLETE & FILLED IN TO BE ACCEPTED St. Lucie County Building and Zoning 2300 Virginia Avenue • ��ORI�P• Ft. Pierce, FL 34982-5652 772-462-1553 S. `4C% Y APPLICATION for BUILDING PERMIT c°Unty CERTIFICATE of CAPACITY/ZONING COMPLIANCE (] PROJECT INFORMATION 1. LOCATION/SITE AD U SS: —l� (5m ; lJul�l u 2. PROJECT NAME: V�Li2 SITE PLAN cNAME: A Cocr 3. PROPERTY TAX ID #: 4. LEGAL DESCRIPTION (attach extra sheets if necessary): (�X LJ�7 Vc �IA-L (,�- 5. PLAT BOOK 6. PAGE NO. 7. BLOCK NO. 8. LOT NO. .1 !t5lw 9. PARCEL SIZE (ACRES/SQ FT.): ° Ob OIL, LOT DIMENSIONS: �� l► ��`7 10. COMPLETE DESCTION OF CONSTRUCTION PROJECTOR WORK ACTIVITY: ���I�ClZ L COI 11. SETBACKS (ACTUAL) FRONT:BACK: RIGHT SIDE: �Li LEFT SIDE: 12. TYPE OF CONSTRUCTION (Check all appropriate boxes) [- ] NEW CONSTRUCTION [ ] EXPANSION/ADDITION [ ] INTERIOR RENOVATION [► r RESIDENTIAL [ ] COMMERCIAL [ ] INDUSTRIAL [ ] OTHER (SPECIFY) 13. DESCRIPTION OF PROPOSED USE: 14. SQ. FT OF CONSTRUCTION: _ la o 4w Ar, 15. SF. FT 1 st FLOOR: 16. VALUE OF CONSTRUCTION: $ 6D The value of construction is used to determine the amount of permit fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction activities. If the value is $2500 or more, a RECORDED Notice of Commencement must be submitted with this application. SLCCDV Form No.: 001-02 H OWNER 1 FORMATION NAME: 2 �/ �4 Ta-4v ' I AT)T)RFCS• 3� 10 M M iA CITY: ra p 4TE, ice- ZIP. 34`1 49 PHONE (DAYTIME): D $ Email: IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE, PLEASE FILL IN NAME AND ADDRESS BELOW. FEE SIMPLE TITLEHOLDER: Al / Q ADDRESS: CITY: STATE: ZIP: PHONE (DAYTDvIE): ( ) CONTRACTOR INFORMATION ST. of FL REG.CERT #- ST. BUSINESS NAME:-`-I-1n��j- LlLy-Q QUALIFIERS NAME: CITY: 1�&a3 K Cl Y 'fir' rl_ �n(nj STATE: PHONE (DAYTIM` E): 64 DqC-) FAX NO. ARCHIT/ENGINE `C C M J U),.QkJ, I CITY: I -U V'T 1P lMJ- PHONE (DAYTEVM): Ta L/ CERT #: c� 49 i l BONDING COMPANY: tj ADDRESS: CITY: STATE: ZIP: MORTGAGE LENDER: At ADDRESS: CITY: STATE: ZIP: IMPORTANT NOTICE: When a permit is issued and it is not pickedf up within 60 days after notification it will be voided and returned to you by mail. OFFICE USE ONLY Bp #: SECTION 2-� TOWNSHIP RANGE —\ MAP NO. ZONING LAND USE Ru LOT CVG % TAZ NO. -_ [— FLOOD ZONE FIRM MAP # — 1 IT FLR ELV MAX HGT CONST TYPE OCCUP TYPE MAX OCCUP # OF FLRS WATER SEWER SPRINKLERS STORMWATER LOT OF REC LOT OF REC LOT SPLIT LOT SPLIT Before 1/1990 After 1/1990 REQUIRED APPROVED REPORT CODE HABITABLE AREA (RADON) RADON FEE PERMIT FEE LIBRARY IMPACT FEE PUBLIC BLD IMPACT FEE CORRECTIO UBIC BLD IMPACT FEE GENERAL PARKS IMPACT FEE ROAD IMPACT FEE CREDIT Y N LAW ENF IMPACT FEE FIRE/EMS FSPECIFY DRIVEWAY REQUIRED Y N DRIVEWAY FEE ADMINISTRATIVE VARIANCE FEE MECHANIC ROOF NON -CONFORMING MISCELLANEOUS SUBS ELECTRIC GAS or LOT OF RECORD FEES REQUIRED PLUMBING FEES DATE SENT TO ADDRESSING: / / REVIEWS DATE RECEIVED DATE COMPLETED FRONT ZONING CO R REVIEW 15 6 , SUPERVISOR REVIEW PLANS REVIEW G •Z3'z0// •Z3-a W VEGETATION REVIEW �?1,1 SEA TURTLE REVIEW MANGROVE REVIEW INITIALS Vic, �•, — _ _ '7 OFFICE USE ONL PLAN REVIDATE EW FEE I% RECEIPT NO.: PERMIT NUMBER: I CONCURRENCY FEE: RECEIPT NO.: CERT. CAP. NO.: ALL INFO MUST BE COMPLETE & FILLED IN TO BE ACCEPTED St. Lucie County Building and Zoning rLA 2300 Virginia Avenue • ORIO Ft. Pierce, FL 34982-5652 772-462-1553 V APPLICATION for BUILDING PERMIT``��f'�'`5 CERTIFICATE of CAPACITY/ZONING COMPLIANCE �'Lj 64 PROJECT �INFORMATION � 1. LOCATION/SITE AD (] SS: -lC�n�-u�,sm ; IJUL+ 241 2. PROJECT NAME: SITE PLAN NAME: ej E j C.iy 3. PROPERTY TAX ID #: 4. LEGAL DESCRIPTION (attach extra sheets if necessary): 5. PLAT BOOK 6. PAGE NO. 7. BLOCK NO. 8. LOT NO. .1 15W _ 9. PARCEL SIZE (ACRESISQ FT.): - (9& 01C+ LOT DIMENSIONS: 10. COMPLETE 'S N OFF CONSTRUCTION PROJECT OR WORK ACTIVITY: 11. SETBACKS (ACTUAL) FRONT: BACK: LN/ RIGHT SIDE: �y LEFT SIDE: _ 12. TYPE OF CONSTRUCTION (Check all appropriate boxes) ] NEW CONSTRUCTION [ ] EXPANSION/ADDITION [I INTERIOR RENOVATION [yam RESIDENTIAL [ ] COMMERCIAL [ ] INDUSTRIAL [I OTHER (SPECIFY) 13. DESCRIPTION OF PROPOSED USE: VI V ' 14. SQ. FT OF CONSTRUCTION: 15. SF. FT 1st FLOOR: 16. VALUE OF CONSTRUCTION: $( The value of construction is used to determine the amount of permit fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction activities. If the value is $2500 or more, a RECORDED Notice of Commencement must be submitted with this application. SLCCDV Form No.: 001-02 RECEIVED JUN 16 2011 Environmental Resou t. Lucie County r OWNER 1 FORMATION - NAME: lb�6j- 4 " G -+V �' - ADDRESS: 3S10 M i A n (� CITY: Cow (QJ►CD SINE: ZIP: 4 4 1 PHONE (DAYTIME): `-f S 2Z U Email: IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE, PLEASE FILL IN NAME AND ADDRESS BELOW./l FEE SIMPLE TTTLEHOLDER: ADDRESS: CTTY: STATE: ZIP: PHONE (DAYTIME): (_) CONTRACTOR INFORMATION ST. of FL REG.CERT #: BUSINESS NAME: QUALIFIERS NAME: :V PHONE (DAYTIME): 'lam ARCHIT/ENGINEER: CITY: VV YT J1 ILL PHONE (DAYMM): U/ COUNTY CERT BONDING COMPANY: 1 ADDRESS: CITY: STATE: ZIP: MORTGAGE LENDER: — ADDRESS: CITY: STATE: ZIP: IMPORTANT NOTICE: When a permit is issued and it is not picked up within 60 days after notification it will be voided and.returned to you by mail. :1 t h .k. mil. Q.� ♦ fl Uiy _ CERTIFICATION: This application is hereby made to obtain a permit to do the work and installations as indicated, and to obtain a certificate of capacity, if applicable, for the permitted work. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits may be required for ELECTRICAL, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AND AIR CONDITIONERS, FENCES, ETC., not otherwise included with this building permit application. St. Lucie County makes no representation that its granting of a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Homeowner Association rules, bylaws or any covenants that may restrict or prohibit such structure. Please consult with your Homeowner's Association and review your deed for any restrictions which may apply. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures (all types), swimming pools, fences, walls, signs, screen rooms, utility substations & accessory uses to another non- residential use. NOTICE TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOBSITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE TO APPLICANT: IF IT IS NOT YOUR RIGHT, TITLE, AND INTEREST THAT IS SUBJECT TO ATTACHMENT: AS A CONDITION OF ISSUANCE OF THIS PERMIT, YOU PROMISE IN GOOD FAITH TO DELIVER A COPY OF THE CONSTRUCTION LIEN LAW NOTICE TO THE PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT. -lbw TRACTOR SIGNATURE CON CT SIGNA STATE OF FLA, STATE OF FLOWMA COUNTY OF (,U CIS COUNTY OF l� The foregoing instrument ,was acknowledged before The foregoing instrument was acknowledged before me this � day of A-L 20_LL—, me this' day of , 20 ( , by '"'� VL�(� � 0111, 9ftltdf/,, by rIC,L who is ers nally known or has produced c� °.�;t� A1��.°.PAo is p onally kno or has produced v: •:p entificag 111V Comm. Expires .� � august 14, 2012 as identification. IF S *. ko No. DD 794463 • 1111111 a7C, 1 Signature of Notary 0%P'. .. , ° 'OUgL1G Q � ignature of Notary �� Commission No. Commission No �� Lb �j�(eal) c •.�jiil f1 4 7 (O' q`��� Loo• My Comm. Expires W" .an• ,.« • Q� �� August 14, 2012 ; .• G . ` � '• No. DD 784463 NOTE: TWO (2) SIGNATURES tRFQU fJiCH SIGNATURE MUST BE NOTARIZ•g {(�I THIS BUILDING PERMIT'AS 9 � UILDER, THE OWNER MUST PERSONA14!i R �S�GP THIS APPLICATION IN' °(l TED ON THE FRONT OF THIS APPLICATIOP�,.,',' f0 F 1FV�es�®�' OWNER BUILDER AFFIDAVIT WILL BE REQUIRED FOR ALL OWNER/BUILDER APPLIeXIIN19. For specific instructions see appropriate permit checklist. �z� OFFICE USE ONLY BP #: 1 �' SECTION TOWNSHIP RANGE LID MAP NO. 42 , ZONING LAND USE LOT CVG % TAZ NO. FLOOD ZONE FIRM MAP # 1 sT FIR ELV MAX HGT CONST TYPE OCCUP TYPE MAX OCCUP # OF FIRS WATER SEWER SPRINKLERS STORMWATER LOT OF REC LOT OF REC LOT SPLIT LOT SPLIT Before 1/1990 After 1/1990 REQUIRED APPROVED REPORT HABITABLE RADON PERMIT CODE AREA FEE FEE (RADON) LIBRARY PUBLIC BLD UBIC BLD PARKS IMPACT IMPACT FEE IMPACT IMPACT FEE CORRECTIO FEE FEE GENERAL SCHOOL ROAD CREDIT Y N LAW ENF IMPACT IMPACT IMPACT FEE FEE FEE FIRE/EMS DRIVEWAY Y N DRIVEWAY ADMINISTRATIVE IMPACT REQUIRED FEE VARIANCE FEE FEE SPECIFY MECHANIC ROOF NON -CONFORMING MISCELLANEOUS SUBS ELECTRIC GAS LOT OF RECORD FEES REQUIRED PLUMBING FEES DATE SENT TO ADDRESSING: REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE CO REVIEW REVIEW REVIEW REVIEW REVIEW RECEIVED /REEVIEW CATE OMPLETED INITIALS f 0 A A •03/01/2011 10 03 FAX 1772489916 CEMEX (A 002/002 Delivery Ticket(s) Page I of 1 Il -coy0fi 3 1wAlk 8050645657 11cr3n�x C"Nom 4wr Ckowmin. ' ak4J4a0J7L3 �AUUSTY WDRUEL.1., COT7 RMTR Mwow. Er..rynw.w• 0aiid/It get IRCKSON WAY uw"r-.r.... N139TH EERCFi FtiflNllAdde Fbimbtla �u�•r �o.w.ro .pgp/a Ywr. 53798074 FAMM rrm 7d51 o8f}afil oau�a►�r+ar.. aw.wr� 31773965 QI NYO ACM 41 feR IwTIIrM �I( Free OMMMUftw 11 rOM ww—tiR Aru w &. QO 8� Aq 6. 00 1! 1 p6 AOOq 8(.NDEDPRPNI i= Yq3 NV . 4 1 ' 1.4Q 1£47818 PLFL 5lJilRI Ms- i`Od 2802749 MMHUNMEKTAL CHARM flWyO9 dpyawr hd�ntlwbfr~ �� you uu pur lI��1A wlwn ItT PsmP4 Did)=WO your oa1ut r sansr9 Aitl � ��+uRla�'1a 1BtN�t� mpd�p . d��rdirrY�rr7 '�+� qi A(A7vr/ n�F 1A � � h►w +w1.lYi rr•Mt Y►ar•p1YM 4�++h�+9Mt SI �rn� Ibr YnnF•�..... w.i � Fee* r. QA"w wh (1Mw r M rd�! ww �earic0 �a r Y. Oa rw Ersw �IrAI i saMF+M •'�r+�t�l ,rAcy.ti�1 w�rEfiilotl8b;. �� C,1►. 141ROs waiat><ao:<o- Mrir� CUM I wo rms"U m owMER9rxKNr4 N!'m=: �f ,yt i�rYA�I Q LQw wAa TEwrw my: 1VNw Nrrrnpn•..p..�.*¢ TR MMt ►nr�lllwr�l w+��r ioM�Yo1. �t1A; 1/ dar my ttidM'r%gVw now w Rob% !beer sUNtaspau. ©REV TRKa . t1R1rn i.DAU NUM, Y — rA �-ac.•wg LAL^V& f►1 OI 1 IACKei(s) OR-Une. If you require further delivery information, please contact your CEMIrX mpresentative. httP://PrdrnYCustolmers/cribin/hcmn hcv/PT? n r nr A r �r�: �,__.r._,.r.• . �O'd ZS: ZZ ZZOZ Z daS OZbZ-b9b-ZZZ: xp3 3NI21dW NI id3w,wns SUMMERLIN MARINE Fax:772-464-7470 Sep 1 2011 11:57 P.01 wrtfJw"J a,.vL-vglr (ZZL) xe�l 0609-v9v (aLL) 9VOS -1d `eweld 1A 0# 'PH 008N 003 •Oul `u011onjisuoo ouijew s,uilaawwns INSPECTION CARD Planning & D¢Yeloptocut Services Online address: Building &Code Regulation Division 23D0'V'irginfa Avenue hftp://www.stfucleco.org/Plannlhg/PerMHng.htm Quirk Links Port pierce, FL 34982 Permit Quick StaLi Lookup Phone: (772) 462 2Y72 Pax; (Tla) 462.64g3 Online Building lnsPWion System Permit #: 51-C- 1106-0113 Confirmation #: 820 Status ISS Issued: 07/06/2011 • Type: Dock/Sea Wall Job Location: 921 JACKSON WAY City: FORT PIERCE Jurisdiction: St. Lucie County Parcel: 1423-802-0028-000/6 Subdiv: Coastal Coves Unit 1 Lot: 26 Block: Flood: AE Hey': Flood Map: 181G Setbacks Left: Right: Pront: Rear: Job Description: REPLACE 100 LINEAR FEET OF SEAWALL WITH VINYL I CONCRETE CAP ; V WATERWARD OF EXISTING WALL - Contractor JOY S YANCY SUMMERLIN'S MARINE CONSTRUCI (772) 464-6090 200 NACO RD # C FORT PIERCE, FL 34940 Property Owner RICHARD L. FIEDLER (772) 460-8228 3870 N AIA # 805 FORT PIERCE, FL 34949 Property Owner PATRICIA M FIEDLER (772) 460-8228 .3970 N Al # 805 'FORT PIERCE, FL 34949 SUB -PERMITS Permit# Status PT Cert#f DBA Owner I Builder Job Dr&rripllion Inspection Notes: For the automated inspection system call (772)462-i261. To schedule an inspection onllne' go to http://airs.slefl.vetrol.coM/AIRSweb.php. All Inspections requested prior to 9:00 PM wilt be scheduled for the next business day. Inspection requests -between 9:U0 PM Friday and 9:00 PM Monday will be scheduled for the following Tuesday. If you require any assistance, please contact the Building Department at (772) 462-2172. Permit #T ype Code papfi tiorr Priori -Date Schad. Res 2t r tion insnector '1106-0113 117 Deadman 1 1106-0113 129 Pile Cap 1 1106-011'3 140 Construction Rough Fr. 1 VINYL SHEETING 1106-0113 806 Batch Tickets (COncret 1 ALL CONCRETE TO BE $000 P.S.1 PER ENGINEER 11W0113 909 Final Inspection 2 rp U a ), ' C ZO'd ZS:IZ TToZ T daS 0zVz—b9b—zzZ:XPA 3NIdlJW NI�d3WWf1S Summerlin's Marine Construction, Inc. 200 Naco Rd. #C Ft. Pierce, FL 34945 (772) 464-6090 Fax (772) 464-7470 July 5, 2011 St. Lucie County Building Dept. Re: Permit Sherman We would like to change the engineer listed on the permit application from Paul Welch Inc. to the following: Bowdoin G. Hutchinson, PE # 70878 2705 N Indian River Drive, Ft. Pierce, FL 34946 PH: 772-528-0076 Thank you, Joy Summerlin Yancy Florida Department of Rick Scott Governor Environmental Protection Jennifer Carroll JUN022011 Richard and Patricia Fiedler 921 Jackson Way Ft. Pierce, FL 34949 Re: File No.: 56-0306167-001 Southeast District Lt. Governor Port St. Lucie Branch Office Herschel T. Vinyard Jr. 1801 SE Hilhnoor Drive, Suite C-204 Port St. Lucie, FL 34952 Secretary (772) 380-1260 File Name: Fiedler, Richard & Patricia Dear Mr. and Mrs. Fiedler: On May 6, 2011, we received your application for an exemption to perform the following activity: replace 100 linear feet of seawall at 1-foot waterward of the existing seawall (measured wetface to wetface), in the location and configuration as shown on the attached drawings. The project is located in a manmade canal, Class II Waters of the State, located adjacent to 921 Jackson Way, Ft. Pierce (Section 23, Township 34 South, Range 40 East), in St. Lucie County (27° 29' 55.84" North Latitude, 80" 18' 17.03" West Longitude). Your application has been reviewed to determine whether it qualifies for any of three kinds of authorization that may be necessary for work in wetlands or waters of the United States. The kinds of authorization are (1) regulatory authorization, (2) proprietary authorization (related to state-owned submerged lands), and (3) federal authorization. The authority for review and the outcomes of the reviews are listed below. Please read each section carefully. Your project may not have qualified for all three forms of authorization. If your project did not qualify for one or more of the authorizations, refer to the specific section dealing with that authorization for advice on how to obtain it. 1. Regulatory Review. - EXEMPTION VERIFIED The Department has reviewed the submitted information and has determined that the project is not expected to cause the release of pollutants in sufficient quantity, quality, content, or character with respect to the circumstances surrounding the location, use, and operation of the project, as to contribute to pollution in contravention of the provisions of Chapters 373 and 403, Florida Statutes (F.S.), or Title 62, Florida Administrative Code (F.A.C.). i rww•.dep.srare. Jl. us File No.: 56-0306167-001 File Name: Fiedler, Richard & Patricia Page 2 Based on the information you submitted, we have determined that your projects to replace a seawall is exempt from the need to obtain a DEP Environmental Resource Permit under Rule 40E-4.051(4)(b), F.A.C. 2. Proprietary Review. - NOT REQUIRED The Department acts as staff to the Board of Trustees of the Internal improvement Trust Fund (Board of Trustees) and issues certain authorizations for the use of sovereignty submerged lands. The Department has the authority to review your projects under Chapters 253 and 258, F.S., Chapters 18-20, and 18-21, F.A.C., and Section 62-343.075, F.A.C. Your project will not occur on sovereignty submerged land. Therefore, pursuant to Chapter 253.77, F.S., authorization from the Board of Trustees is not required. 3. Federal Review (SPGP) - GRANTED Federal authorization for the proposed projects is reviewed by DEP pursuant to an agreement between the Department and the U.S. Army Corps of Engineers (Corps). The agreement is outlined in a document titled Coordination Agreement Between the U.S. Army Corps of Engineers and the Florida Department of Environmental Protection State Programmatic General Permit, Section 10 of the Rivers and Harbor Act of 1899 and Section 404 of the Clean Water Act. Your project has been reviewed for compliance with a State Programmatic General Permit (SPGP). As shown on the attached drawings, the proposed project is consistent with the SPGP program The attached Corps general conditions apply to your project. No further permitting for this activity is required by the Corps. This exemption verification is based on the information you provided the Department and the statutes and rules in effect when the information was submitted. This verification will expire after one year, and will not be valid at any other time if site conditions materially change, the project design is modified, or the statutes or rules governing the exempt activity are amended. However, the activity may still be conducted without further notification to or verification from the Department after the one-year expiration of this verification, provided:1) the project design does not change; 2) site conditions do not materially change; and 3) there are no changes to the statutes or rules governing the exempt activity. In the event you need to re -verify the exempt status for the activity after the one-year expiration of this verification, a new application and verification fee will be required. Any substantial modifications to the project design should be submitted to the Department for review, as changes may result in a permit being required. Conditions of compliance with the regulatory exemption are contained in Attachment A. File No.: 56-0306167-001 File Name: Fiedler, Richard & Patricia Page 3 This letter does not relieve you from the responsibility of obtaining other permits (federal, state, or local) that may be required for the projects. NOTICE OF RIGHTS OF SUBSTANTIALLY AFFECTED PERSONS This letter acknowledges that the proposed activity is exempt from ERP permitting requirements under Rule 40E-4.051(4)(b), F.A.C. This determination is final and effective on the date filed with the Clerk of the Department unless a sufficient petition for an administrative hearing is timely filed under sections 120.569 and 120.57 of the Florida Statutes as provided below. If a sufficient petition for an administrative hearing is timely filed, this determination automatically becomes only proposed agency action subject to the result of the administrative review process. Therefore, on the filing of a timely and sufficient petition, this action will not be final and effective until further order of the Department. The procedures for petitioning for a hearing are set forth in the attached notice. This determination is based on the information you provided the Department and the statutes and rules in effect when the application was submitted and is effective only for the specific activity proposed. This determination shall automatically expire if site conditions materially change or the governing statutes or rules -are amended. In addition, any substantial modifications in your plans should be submitted to the Department for review, as changes may result in a permit being required. In any event, this determination shall expire after one year. Be advised that your neighbors and other parties who maybe substantially affected by the proposed activity allowed under this determination of exemption have a right to request an administrative hearing on the Department's decision that the proposed activity qualifies for this exemption. Because the administrative hearing process is designed to redetermine final agency action on the application, the filing of a petition for an administrative hearing may result in a final determination that the proposed activities are not authorized under the exemption established under Rule 40E- 4.051(4)(b), F.A.C. The Department will not publish notice of this determination. Publication of this notice by you is optional and is not required for you to proceed. However, in the event that an administrative hearing is held and the Department's determination is reversed, proceeding with the proposed activity before the time period for requesting an administrative hearing has expired would mean that the activity was conducted without the required permit. If you wish to limit the time within which all substantially affected persons may request an administrative hearing, you may elect to publish, at your own expense, the enclosed notice (Attachment A) in the legal advertisement section of a newspaper of general File No.: 56-0306167-001 File Name: Fiedler, Richard & Patricia Page 4 circulation in the county where the activity is to take place. A single publication will suffice. If you wish to limit the time within which any specific person(s) may request an administrative hearing, you may provide such person(s), by certified mail, a copy of this determination, including Attachment A. For the purposes of publication, a newspaper of general circulation means a newspaper meeting the requirements of sections 50.011 and 50.031 of the Florida Statutes. In the event you do publish this notice, within- seven days of publication, you must provide to the following address proof of publication issued by the newspaper as provided in section 50.051 of the Florida Statutes. If you provide direct written notice to any person as noted above, you must provide to the following address a copy of the direct written notice. Florida Department of Environmental Protection Southeast District Branch Office 1801 SE Hillmoor Drive, Suite C-204 Port St. Lucie, Florida 34952 If you have any questions, please contact Cindy Lott at 772/380-1273, or at cynthia.lott@dep.state.fl.us. When referring to your project, please use the FDEP file name and number ' d above. Z Eric M. Shea Date Environmental Manager Submerged Lands and Environmental Resources Program EMS/cl Enclosures cc. joy Summerlin, Summerlin's Marine Construction, SUMMERLIN7CS@aol.com FILING AND ACKNOWLEDGMENT FILED, on this date, pursuant to 120.52(9), Florida Statutes, with the designated Department Clerk, receipt of which is hereby acknowledged. ClerkDate Attachment A STATE OF FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION NOTICE OF DETERMINATION OF EXEMPTION File No.: 56-0306167-001 The Department of Environmental Protection gives notice that to replace 100 linear feet of seawall at 1-foot waterward of the existing seawall (measured wetface to wetface), has been determined to be exempt from requirements to obtain an environmental resource permit. The project is located in a manmade canal, Class 11 Waters of the State, located adjacent to 92I Jackson Way, Ft. Pierce (Section 23, Township 34 South, Range 40 East), in SL Lucie County (27° 29' 55.84" North Latitude, 800 18' 17.03" West Longitude). A person whose substantial interests are affected by the Department's action may petition for an administrative proceeding (hearing) under sections 120.569 and 120.57 of the Florida Statutes. The petition must contain the information set forth below and must be filed (received by the clerk) in the Office of General Counsel of the Department at 3900 Commonwealth Boulevard, Mail Station 35, Tallahassee, Florida 32399-3000. Mediation is not available. If a timely and sufficient petition for an administrative hearing is filed, other persons whose substantial interests will be affected by the outcome of the administrative process have the right to petition to intervene in the proceeding. Intervention will be permitted only at the discretion of the presiding officer upon the filing of a motion in compliance with rule 28-106.205 of the Florida Administrative Code. In accordance with rule 62-110.106(3), F.A.C., petitions for an administrative hearing must be filed within 21 days of publication of the notice or receipt of written notice, whichever occurs first. Under rule 62-110.106(4) of the Florida Administrative Code, a person whose substantial interests are affected by the Department's action may also request an extension of time to file a petition for an administrative hearing. The Department may, for good cause shown, grant the request for an extension of time. Requests for extension of time must be filed with the Office of General Counsel of the Department at 3900 Commonwealth Boulevard, Mail Station 35, Tallahassee, Florida 32399-3000 prior to the applicable deadline. A timely request for extension of time shall toll the running of the time period for filing a petition until the request is acted upon. Upon motion by the requesting party showing that the failure to file a request for an extension of time before the deadline was the result of excusable neglect, the Department may also grant the requested extension of time. The petitioner shall mail a copy of the petition to the applicant at the address indicated above at the time of filing. The failure of any person to file a petition for an administrative heating within the appropriate time period shall constitute a waiver of that right. A petition that disputes the material facts on which the Department's action is based must contain the following information: (a) The name and address of each agency affected and each agency's file or identification number, if known; (b) The name, address, and telephone number of the petitioner, the name, address, and telephone number of the petitioner's representative, if any, which shall be the address for service purposes during the course of the proceeding; and an explanation of how the petitioner's substantial interests are or will be affected by the agency determination; (c) A statement of when and how the petitioner received notice of the agency decision; (d) A statement of all disputed issues of material fact. If there are none, the petition must so indicate; (e) A concise statement of the ultimate facts alleged, including the specific facts the petitioner contends warrant reversal or modification of the agency's proposed action; (f) A statement of the specific rules or statutes that the petitioner contends require reversal or modification of the agency's proposed action; and (g) A statement of the relief sought by the petitioner, stating precisely the action that the petitioner wishes the agency to take with respect to the agency's proposed action. A petition that does not dispute the material facts on which the Department's action is based shall state that no such facts are in dispute and otherwise shall contain the same information as set forth above, as required by rule 28-106.301. Under sections 120.569(2)(c) and (d) of the Florida Statutes, a petition for administrative hearing shall be dismissed by the agency if the petition does not substantially comply with the above requirements or is untimely filed. Complete copies of all documents relating to this determination of exemption are available for public inspection during normal business hours, 8:00 am, to 5:00 p.m., Monday through Friday, at the Southeast District Branch Office, 1801 SE Hillmoor Drive, Suite C-204 Port St. Lucie, Florida. GENERAL CONDITIONS FOR FEDERAL AUTHORIZATION -FOR SPGP IV General Conditions 1. The time limit for completing the work authorized ends on September 1, 2011. 2. You must maintain the activity authorized by this permit in good condition and in conformance with the terms and conditions of this permit. You are not relieved of this requirement if you abandon the permitted activity, although you may make a good faith transfer to a third party in compliance with General Condition 4 below. Should you wish to cease to maintain the authorized activity or should you desire to abandon it without a good faith transfer, you must obtain a modification of this permit from this office, which may require restoration of the area. 3. If you discover any previously unknown historic or archeological remains while accomplishing the activity authorized by this permit, you must immediately notify this office of what you have found. We will initiate the Federal and State coordination required to determine if the remains warrant a recovery effort or if the site is eligible for listing in the National Register of Historic Places. 4. If you sell the property associated with this permit, you must obtain the signature and mailing address of the new owner in the space provided below and forward a copy of the permit to this office to validate the transfer of thus authorization. 5. If a conditioned water quality certification has been issued for your projects, you must comply with the conditions specified in the certification as special conditions to this permit. 6. You must allow representatives from this office to inspect the authorized activity at any time deemed necessary to ensure that it is being or has been accomplished in accordance with the terms and conditions of your permit Further Information: 1. Limits of this authorization. a. This permit does not obviate the need to obtain other Federal, State, or local authorizations required by law. b. This permit does not grant any property rights or exclusive privileges. c. This permit does not authorize any injury to the property or rights of others. d. This permit does not authorize interference with any existing or proposed Federal projects. 2. Limits of Federal Liability. In issuing this permit, the Federal Government does not assume any liability for the following: a. Damages to the permitted project or uses thereof as a result of other permitted or unpermitted activities or from natural causes. b. Damages to the permitted project or uses thereof as a result of current or future activities undertaken by or on behalf of the United States in the public interest. c. Damages to persons, property, or to other permitted or unpermitted activities or structures caused by the activity authorized by this permit d. Design or construction deficiencies associated with the permitted work. e. Damage claims associated with any future modification, suspension, or revocation of this permit. 3. Reliance on Applicant's Data: The determination of this office that issuance of this permit is not contrary to the public interest was made in reliance on the information you provided. 4. Reevaluation of Permit Decision This office may reevaluate its decision on this permit at any time the circumstances warrant. Circumstances that could require a reevaluation include, but are not limited to, the following: a. You fail to comply with the terms and conditions of this permit. b. The information provided by you in support of your permit application proves to have been false, incomplete, or inaccurate (see 3 above). c_ Significant new information surfaces which this office did not consider in reaching the original public interest decision. 5. Such a reevaluation may result in a determination that it is appropriate to use the suspension, modification, and revocation procedures contained in 33 CFR 325.7 or enforcement procedures such as those contained in 33 CFR 326.4 and 326.5. The referenced enforcement procedures provide for the issuance of an administrative order requiring you comply with the terms and conditions of your permit and for the initiation of legal action where appropriate. You will be required to pay for any corrective measures ordered by this office, and if you fail to comply with such directive, this office may in certain situations (such as those specified in 33 CFR 209.170) accomplish the corrective measures by contract or otherwise and bill you for the cost. 6. When the structures or work authorized by this permit are still in existence at the time the property is transferred, the terms and conditions of this permit will continue to be binding on the new owner(s) of the property. To validate the transfer of this permit and the associated liabilities associated with compliance with its terms and conditions, have the transferee sign and date below. (TRANSFEREE -SIGNATURE) (NAME -PRINTED) (ADDRESS) (DATE) STANDARD MANATEE CONDITIONS FOR IN -WATER WORK 2009 The permittee shall comply with the following conditions intended to protect manatees from direct project effects: a. All personnel associated with the project shall be instructed about the presence of manatees and manatee speed zones, and the need to avoid collisions with and injury to manatees. The permittee shall advise all construction personnel that there are civil and criminal penalties for harming, harassing, or killing manatees which are protected under the Marine Mammal Protection Act, the Endangered Species Act, and the Florida Manatee Sanctuary Act. b. All vessels associated with the construction project shall operate at "Idle Speed/No Wake" at all times while in the .immediate area and while in water where the draft of the vessel provides less than a four -foot clearance from the bottom. All vessels will follow routes of deep water whenever possible. C. Siltation or turbidity barriers shall be made of material in which manatees cannot become entangled, shall be properly secured, and shall be regularly monitored to avoid manatee entanglement or entrapment. Barriers must not impede manatee movement. d. All on -site project personnel are responsible for observing water -related activities for the presence of manatee(s). All in -water operations, including vessels, must be shutdown if a manatee(s) comes within 50 feet of the operation. Activities will not resume until the manatee(s) has moved beyond the 50-foot radius of the project operation, or until 30 minutes elapses if the manatee(s) has not reappeared within 50 feet of the operation. Animals must not be herded away or harassed into leaving. e. Any collision with or injury to a manatee shall be reported immediately to the FWC Hotline at 1 - 888-404-FWCC. Collision and/or injury should also be reported to the U.S. Fish and Wildlife Service in Jacksonville (1-904-731-3336) for north Florida or Vero Beach (1-772-562-3909) for south Florida. f. Temporary signs concerning manatees shall be posted prior to and during all in -water project activities. All signs are to be removed by the permittee upon completion of the project. Awareness signs that have already been approved for this use by the Florida Fish and Wildlife Conservation Commission (FWC) must be used (see MyFWC.com). One sign which reads Caution: Boaters must be posted. A second sign measuring at least 81/2" by 11" explaining the requirements for "Idle Speed/No Wake" and the shut down of in -water operations must be posted in a location prominently visible to all personnel engaged in water -related activities. CAUTMNM- MANATEE HABITAT A11 project vessela IDLE SPEED /.NO WAKE When a manatee is within 50 feet of work all in -water activities must SHUT DOWN Report any collision with or injury to a manatee. Wildlife Alert: 1-888-404-FWCC (3J22) eel I * F VC or #FWC S,SAT or f of UNITED STATES DEPARTMENT OF .COMIIIERCE National Oceanic and Atmospheric Administration NATIONAL MARINE FISHERIES SERVICE Southeast Regional Office 263 13th Avenue South St. Petersburg, FL 33701 SEA TURTLE AND SMALLTOOTH SAWFISH CONSTRUCTION CONDITIONS The pennittee shall comply with the following protected species construction conditions: a. The permittee shall instruct all personnel associated with the project of the potential presence of these species and the need to avoid collisions with sea turtles and smalltooth sawfish. All construction personnel are responsible for observing water -related activities for the presence of these species. b. The permittee shall advise all construction personnel that there are civil and criminal penalties for harming, harassing, or killing sea turtles or smalltooth sawfish, which are protected under the Endangered Species Act of 1973. c. Siltation barriers shall be made of material in which a sea turtle or smalltooth'sawfish cannot become entangled, be properly secured, and be regularly monitored to avoid protected species entrapment. Barriers may not block sea turtle or smalltooth sawfish entry to or exit from designated critical habitat without prior agreement from the National Marine Fisheries Service's Protected Resources Division, St. Petersburg, Florida. d. All vessels associated with the construction project shall operate at "no wake/idle" speeds at all times while in the construction area and while in water depths where the draft of the vessel provides less than a four - foot clearance from the bottom. All vessels will preferentially follow deep -water routes (e.g., marked channels) whenever possible. e. If a sea turtle or smalltooth sawfish is seen within 100 yards of the active daily construction/dredging operation or vessel movement, all appropriate precautions shall be implemented to ensure its protection. These precautions shall include cessation of operation of any moving equipment closer than 50 feet of a sea turtle or smalltooth sawfish. Operation of any mechanical construction equipment shall cease immediately if a sea turtle or smalltooth sawfish is seen within a 50-ft radius of the equipment. Activities may not resume until the protected species has departed the project area, of its own volition. Any collision with and/or injury to a sea turtle or smalltooth sawfish shall be reported immediately to the National Marine Fisheries Service's Protected Resources Division (727-824-5312) and the local authorized sea turtle stranding/rescue organization.. g. Any special construction conditions, required of your specific project, outside these general conditions, if applicable, will be addressed in the primary consultation. Revised: March 23, 2006 O:\fonnslSea Turtle and Smalltooth Sawfish Construction Conditions.doc "�+tsrra MAY 0 6 2011 r-L DEP PORT ST. LUCIE LOCATInAl VICINITY REVISED R. E - CE,=11 V EX15TING FENCE De�t. of �"L L. "d, . 1. 0— PROP05ED BULKHEAD WWATERWARD:OF EXISTING BULKHEAD) NOTE5 _Coastal COV65 Unit / Lot 26 921 Jackson Way EXISTING CONCRETE SEAWALL - WA TER WA Y TO INDIAN RIVER EBB / FLOOD CANAL MOTO /00'.:t M/lW to A4HW, 1.) 25 % OF IGOWNE WIDTH OF THE WATERWAY = 25� 25'SHALL REMAIN UNOBSTRUCTED BYDOCK5, MOORING OR DOLPHIN POLES, OR MOORED BOATS. 2.) NO 033TRUMION5 SHALL MEND MORE THAN 40'(14qrHIIV 10' OF CENTERLINE OF WATERWAY) 3.) RENTING OF DdCK5, DOCK SPACE, OR MOORINGS OR THE RENTAL OF BOA T5 FOR ANY FURP05e WHA T50EVER- /5 PROHIBITED. Richard L and RatrIcia M Fledler 92 / Jackson Way Fort Pierce, FL 34946 EXISTING PROPOSED BULKHEAD (I'' WA MR WA RD OF El(15T7NG.3UtKHtAQ) BULKHEAD PLAN INFORMATION TAKEN FROM6T LUCIE COUNTY lmlollvuy APPRA15ERS'OFFICE MAP* SURVEY DRAWNG PROPOSED BULKHEAD SCALE. ism = P-ON ,Wf: 041221-2011 SHWr 2- OF 3 5HEM.9 RECEIVED MAY 0 6 2011 F1. DEP PQR? ST.1.UGiE SEAWALL / BULKHEAD SECTION VIEW NEW WALL TO BE PLACED WITH/N P WATERWARD OF EX13T/N6 WALL ELEVATION SCALE: 3/e" = 1 o" BEST 1MIANAGEMEAIT PRACTICES TD BE USED SCALD %' DURING CONSTRUCTION DEADMAN - 24"X.24'X 12" w104 BARS @ 6" O.C. ,f7 BAR IN PVC SLEEVE (MINIMUM 10 NOTE.. EACH WAY LENGTH) w @ lO' M.4X. O: C. 112":BEND @ EACH END ALL CONCRETE SHALL BE 3000 P5/ 1-- EXLSTING-BULKHEAD%5EAWALL ' rnr� fl l liutiw►e K►;I,��su wnHryyo�niihe,Yal�Inui>trltv�, (TO REMAIN 11v PLACE) 11tnlbAl�IHYa h 3 5TIRRUP3 1 & /MAXIMUM O.C. -(9 24" O.C. DEADMEN (BEYOND) 1.4' WIDEx 10" o' '' " '• f. � I f1 04EP CONCRETE I4"x 10" CONCRETI Q CAP w/ (4) 44 BA95 CONTINUOUS f + I 91 N ; 4 L 1 J V! V S�E6`Tl 'G I I WATERLINE ;w j f TEk _ -��oce1 FVJ 1 VINYL SHEETING 1 MINIMUM 1: I ' I 7 ' PENETRATION INTO yr r4 T n f SANOY 501L ' �. LEGEND rhLT7, {,r� :- O.C. = ON CENTER 4 4 §" R.C. = ROUGH CUT ri}xyF{i'n I r t t'rs n': *���say s• ld = DIAMETER` 1' { l f pY TF4y tr Y,ikj G GCA = CHROMATED COPPER ARSENATE Richard L and Patricia M Fiedler 92 / Jackson Way tort Plerce, FL 34949 PROPOSED BULKHEAD ' f I 5CAL€. AS. NOTED DATE:' 04-12.212011 SHEET 3 . I OF .3 5HEt?5 JOSEPH E. SMITH, CLERK OF THE CIRCUIT COURT - SAINT LUCIE COUNTY FILE # 3595590 OR B(' 3296 PACE 1528, Recorded 05/25/201]F 01:03 PM F 7 NOTICE OF CONAMNCEMENT The undersigned hereby given notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida statutes the following information is provided in the Notice of commencement. Q� 1. DESCRIMON OF PROPERTY (Legal description and street address) TAR FOLIO NUMBER:14a�7J' 2. GENERAL DESCRIPTION OF IMI 3.OWNER INFORMATION: a. d. Name and address of fee simple titleholder (if 4. c. interest in property [ rz Ltc, 5. SURETY'S NAME, ADDRESS AND PHONE NUMBER AND BOND AMOUNT: 6. LENDER'S NAME, ADDRESS AND PHONE NUMBER: 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13 (1)(a) 7., Florida Statutes: NAME, ADDRESS AND PHONE NUMBER: S. In addition to himself or herself, Owner designates the following to receive a copy of the Lieaor's Notice as provided in Section 713.13 (1)(b), Florida Statutes: NAME, ADDRESS AND PHONE NUMBER: 9. Expiration date of notice of commencement (the expiration date is 1 year from the date of recording unless a different date is specified) , 20_. orgmrore or rrwner or mint Name and Provide Signatory's T11 WOffice Owner's Authorized Officer/Director/Parhaer/Manager State of Flo County Of- ttQ 0 The f om^g'' m.e_tro� nt aclmow edged before me this-! day of t ' """X 70L By Z Kti OIJLQ.✓ , as At ), Il0 i (Name of person) (Type of authority... e.g. Owner, officer, trustee, attorney in fact) • V•(Name of party on behalf of whom instrument was executed) Personally Known or produced the following type of II): _ �"01 Cis yiJl.t�. tfsa �� zR�- C •�5P. o (Printed Name of Notary Public) (Signature of Notary Public) !tee: ' 1W, My con ALW Under penalties of perjury, I declare that I have read the foregoing end that the facts in it n tree to the best of my la*$apehReB belief (section 92.525, Florida Statutes). :_ e. Signature(s) of�OOwoer(s`)Aor Owmr(s)' Authorized O®cedDirector/Partner/Maoaggeer who � o signed above: IL T� lea By 1 . f�LpLx-I�LY St.. LWE COUNTY TN ; I 0 CERTIFY THAT THI Y N� COAENCL ALSFP Date A""kPY ViLE CU Florida Department of Go Scott Governor Environmental Protection JUN 0 2 2011 Richard and Patricia Fiedler 921 Jackson Way Ft. Pierce, FL 34949 Southeast District Port St. Lucie Branch Office 1801 SE 11iIhnoor Drive, Suite C-204 Port St. Lucie, FL 34952 (772) 380-1260 Re: File No.: 56-0306167-001 File Name: Fiedler, Richard & Patricia Dear Mr. and Mrs. Fiedler: Jennifer Carroll Lt. Governor Herschel T. Vinyard Jr. Secretary 6 - v1/3 ST. LUCIE COUNTY BUILDING DIVISION REVIEPI FOR_ 1 RE*EWED-BY DATE PLANS AND PERMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE On May 6, 2011, we received your application for an exemption to perform the following activity: replace 100 linear feet of seawall at 1-foot waterward of the existing seawall (measured wetface to wetface), in the location and configuration as shown on the attached drawings. The project is located in a manmade canal, Class II Waters of the State, located adjacent to 921 Jackson Way, Ft. Pierce (Section 23, Township 34 South, Range 40 East), in St. Lucie County (27' 29' 55.84" North Latitude, 80' 18' 17.03" West Longitude). Your application has been reviewed to determine whether it qualifies for any of three kinds of authorization that may be necessary for work in wetlands or waters of the United States. The kinds of authorization are (1) regulatory authorization, (2) proprietary authorization (related to state-owned submerged lands), and (3) federal authorization. The authority for review and the outcomes of the reviews are listed below. Please read each section carefully. Your project may not have qualified for all three forms of authorization. If your project did not qualify for one or more of the authorizations, refer to the specific section dealing with that authorization for advice on how to obtain it. 1. Regulatory Review. - EXEMPTION VERIFIED The Department has reviewed the submitted information and has determined that the project is not expected to cause the release of pollutants in sufficient quantity, quality, content, or character with respect to the circumstances surrounding the location, use, and operation of the project, as to contribute to pollution in contravention of the provisions of Chapters 373 and 403, Florida Statutes (F.S.), or Title 62, Florida Administrative Code (F.A.C.). CONCEALED FASTENERS OR ATTACHMENTS THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS ARE THE RESPONSIBILITY OF THE REQUIRED BY FIELD INSPECTORS THAT CONTRACTOR OF RECORD MAY BE NECESSARY IN ORDER TO 90-M Y WITH A46IPOW9 6E 90®E9: File No.: 56-0306167-001 File Name: Fiedler, Richard & Patricia Page 2 Based on the information you submitted, we have determined that your projects to replace a seawall is exempt from the need to obtain a DEP Environmental Resource Permit under Rule 40E-4.051(4)(b), F.A.C. 2. Proprietary Review. - NOT REQUIRED The Department acts as staff to the Board of Trustees of the Internal Improvement Trust Fund (Board of Trustees) and issues certain authorizations for the use of sovereignty submerged lands. The Department has the authority to review your projects under Chapters 253 and 258, F.S., Chapters 18-20, and 18-21, F.A.C., and Section 62-343.075, F.A.C. Your project will not occur on sovereignty submerged land. Therefore, pursuant to Chapter 253.77, F.S., authorization from the Board of Trustees is not required. 3. Federal Review (SPGP) - GRANTED Federal authorization for the proposed projects is reviewed by DEP pursuant to an agreement between the Department and the U.S. Army Corps of Engineers (Corps). The agreement is outlined in a document titled Coordination Agreement Between the U.S. Army Corps of Engineers and the Florida Department of Environmental Protection State Programmatic General Permit, Section 10 of the Rivers and Harbor Act of 1899 and Section 404 of the Clean Water Act. Your project has been reviewed for compliance with a State Programmatic General Permit (SPGP). As shown on the attached drawings, the proposed project is consistent with the SPGP program. The attached Corps general conditions apply to your project. No further permitting for this activity is required by the Corps. This exemption verification is based on the information you provided the Department and the statutes and rules in effect when the information was submitted. This verification will expire after one year, and will not be valid at any other time if site conditions materially change, the project design is modified, or the statutes or rules governing the exempt activity are amended. However, the activity may still be conducted without further notification to or verification from the Department after the one-year expiration of this verification, provided:1) the project design does not change; 2) site conditions do not materially change; and 3) there are no changes to the statutes or rules governing the exempt activity. In the event you need to re -verify the exempt status for the activity after the one-year expiration of this verification, a new application and verification fee will be required. Any substantial modifications to the project design should be submitted to the Department for.review, as changes may result in a permit being required. Conditions of compliance with the regulatory exemption are contained in Attachment A. �Tfl File No.: 56-0306167-001 File Name: Fiedler, Richard & Patricia Page 3 This letter does not relieve you from the responsibility of obtaining other permits (federal, state, or local) that may be required for the projects. NOTICE OF RIGHTS OF SUBSTANTIALLY AFFECTED PERSONS This letter acknowledges that the proposed activity is exempt from ERP permitting requirements under Rule 40E-4.051(4)(b), F.A.C. This determination is final and effective 'on the date filed with the Clerk of the Department unless a sufficient.petition for an administrative hearing is timely filed under sections 120.569 and 120.57 of the Florida Statutes as provided below. If a sufficient petition for an administrative hearing is timely filed, this determination automatically becomes only proposed agency action subject to the result of the administrative review process. Therefore, on the filing of a timely and sufficient petition, this action will not be final and effective until further order of the Department. The procedures for petitioning for a hearing are set forth in the attached notice. This determination is based on the information you provided the Department and the statutes and rules in effect when the application was submitted and is effective only for the specific activity proposed. This determination shall automatically expire if site conditions materially change or the governing statutes or rules are amended. In addition, any substantial modifications in your plans should be submitted to the Department for review, as changes may result in a permit being required. In any event, this determination shall expire after one year. Be advised that your neighbors and other parties who may be substantially affected by the proposed activity allowed under this determination of exemption have a right to request an administrative hearing on the Department's decision that the proposed activity qualifies for this exemption. Because the administrative hearing process is designed to redetermine final agency action on the application, the filing of a petition for an administrative hearing may result in a final determination that the proposed activities are not authorized under the exemption established under Rule 40E- 4.051(4)(b), F.A.C. The Department will not publish notice of this determination. Publication of this notice by you is optional and is not required for you to proceed. However, in the event that an administrative hearing is held and the Department's determination is reversed, proceeding with the proposed activity before the time period for requesting an administrative hearing has expired would mean that the activity was conducted without the required permit. If you wish to limit the time within which all substantially affected persons may request an administrative hearing, you may elect to publish, at your own expense, the enclosed notice (Attachment A) in the legal advertisement section of a newspaper of general File No.: 56-0306167-001 File Name: Fiedler, Richard & Patricia Page 4 circulation in the county where the activity is to take place. A single publication will suffice. . If you wish to limit the time within which any specific person(s) may request an administrative hearing, you may provide such person(s), by certified mail, a copy of this determination, including Attachment A. For the purposes of publication, a newspaper of general circulation means a newspaper meeting the requirements of sections 50.011 and 50.031 of the Florida Statutes. In the event you do publish this notice, within- seven days of publication, you must provide to the following address proof of publication issued by the newspaper as provided in section 50.051 of the Florida Statutes. If you provide direct written notice to any person as noted above, you must provide to the following address a copy of the direct written notice. Florida Department of Environmental Protection Southeast District Branch Office 1801 SE 11illmoor Drive, Suite C-204 Port St. Lucie, Florida 34952 If you have any questions, please contact Cindy Lott at 772/380-1273, or at cynthia.lott®dep.state.fl.us. When referring to your project, please use the FDEP file name and number ' ed above. Eric M. Shea Date Environmental Manager Submerged Lands and Environmental Resources Program EMS/cl Enclosures cc. Joy Summerlin, Summerlin's Marine Construction, SUMMERLIN7CSQaol.com FILING AND ACKNOWLEDGMENT FILED, on this date, pursuant to 120.52(9), Florida Statutes, with the designated Department Clerk, receipt of which is hereby acknowledged. 24&4;�L� LI-t Clerk ate Attachment A File No.: 56-0306167-001 STATE OF FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION NOTICE OF DETERMINATION OF EXEMPTION The Department of Environmental Protection gives notice that to replace 100 linear feet of seawall at 1-foot waterward of the existing seawall (measured wetface to wetface), has been determined to be exempt from requirements to obtain an environmental resource permit. The project is located in a manmade canal, Class 11 Waters of the State, located adjacent to 921 Jackson Way, Ft. Pierce (Section 23, Township 34 South, Range 40 East), in St. Lucie County (27° 29' S5.84" North Latitude, 80' 18' 17.03" West Longitude). A person whose substantial interests are affected by the Department's action may petition for an administrative proceeding (hearing) under sections 120.569 and 120.57 of the Florida Statutes. The petition must contain the information set forth below and must be filed (received by the clerk) in the Office of General Counsel of the Department at 3900 Commonwealth Boulevard, Mail Station 35, Tallahassee, Florida 32399-3000. Mediation is not available. If a timely and sufficient petition for an administrative hearing is filed, other persons whose substantial interests will be affected by the outcome of the administrative process have the right to petition to intervene in the proceeding. Intervention will be permitted only at the discretion of the presiding officer upon the filing of a motion in compliance with rule 28-106.205 of the Florida Administrative Code. In accordance with rule 62-110.106(3), F.A.C., petitions for an administrative hearing must be filed within 21 days of publication of the notice or receipt of written notice, whichever occurs first. Under rule 62-110.I06(4) of the Florida Administrative Code, a person whose substantial interests are affected by the Department's action may also request an extension of time to file a petition for an administrative hearing. The Department may, for good cause shown, grant the request for an extension of time. Requests for extension of time must be filed with the Office of General Counsel of the Department at 3900 Commonwealth Boulevard, Mail Station 35, Tallahassee, Florida 32399-3000 prior to the applicable deadline. A timely request for extension of time shall toll the running of the time period for filing a petition until the request is acted upon. Upon motion by the requesting party showing that the failure to file a request for an extension of time before the deadline was the result of excusable neglect, the Department may also grant the requested extension of time. The petitioner shall mail a copy of the petition to the applicant at the address indicated above at the time of filing. The failure of any person to file a petition for an administrative hearing within the appropriate time period shall constitute a waiver of that right. A petition that disputes the material facts on which the Department's action is based must contain the following information: (a) The name and address of each agency affected and each agency's file or identification number, if known; (b) The name, address, and telephone number of the petitioner, the name, address, and telephone number of the petitioner's representative, if any, which shall be the address for service purposes during the course of the proceeding; and an explanation of how the petitioner's substantial interests are or will be affected by the agency determination; (c) .A statement of when and how the petitioner received notice of the agency decision; (d) A statement of all disputed issues of material fact. If there are none, the petition must so indicate; (e) A concise statement of the ultimate facts alleged, including the specific facts the petitioner contends warrant reversal or modification of the agency's proposed action; (f) A statement of the specific rules or statutes that the petitioner contends require reversal or modification of the agency's proposed action; and (g) A statement of the relief sought by the petitioner, stating precisely the action that the petitioner wishes the agency to take with respect to the agency's proposed action. A petition that does not dispute the material facts on which the Department's action is based shall state that no such facts are in dispute and otherwise shall contain the same information as set forth above, as required by rule 28-106.301. Under sections 120.569(2)(c) and (d) of the Florida Statutes, a petition for administrative hearing shall be dismissed by the agency if the petition does not substantially comply with the above requirements or is untimely filed. Complete copies of all documents relating to this determination of exemption are available for public inspection during normal business hours, 8:00 am. to 5:00 p.m., Monday through Friday, at the Southeast District Branch Office, 1801 SE Hillmoor Drive, Suite C-204 Port St. Lucie, Florida. r6'yy, �/�r �!• GENERAL CONDITIONS FOR FEDERAL AUTHORIZATION FOR SPGP IV General Conditions 1. The time limit for completing the work authorized ends on September 1, 2011. 2. You must maintain the activity authorized by this permit in good condition and in conformance with the terms and conditions of this permit. You are not relieved of this requirement if you abandon the permitted activity, although you may make a good faith transfer to a third party in compliance with General Condition 4 below. Should you wish to cease to maintain the authorized activity or should you desire to abandon it without a good faith transfer, you must obtain a modification of this permit from this office, which may require restoration of the area. 3. If you discover any previously unknown historic or archeological remains while accomplishing the activity authorized by this permit, you must immediately notify this office of what you have found. We will initiate the Federal and State coordination required to determine if the remains warrant a recovery effort or if the site is eligible for listing in the National Register of Historic Places. 4. If you sell the property associated with this permit, you must obtain the signature and mailing address of the new owner in the space provided below and forward a copy of the permit to this office to validate the transfer of this authorization. 5. If a conditioned water quality certification has been issued for your projects, you must comply with the conditions specified in the certification as special conditions to this permit.. 6. You must allow representatives from this office to inspect the authorized activity at any time deemed necessary to ensure that it is being or has been accomplished in accordance with the terms and conditions of your permit. Further Information: 1. Limits of this authorization. a. This permit does not obviate the need to obtain other Federal, State, or local authorizations required by law. b. This permit does not grant any property rights or exclusive privileges. c. This permit does not authorize any injury to the property or rights of others. d. This permit does not authorize interference with any existing or proposed Federal projects. 2. Limits of Federal Liability. In issuing this permit, the Federal Government does not assume any liability for the following: a. Damages to the permitted project or uses thereof as a result of other permitted or unpermitted activities or from natural causes. b. Damages to the permitted projector uses thereof as a result of current or future activities undertaken by or on behalf of the United States in the public interest. c. Damages to persons, property, or to other permitted or unpermitted activities or structures caused by the activity authorized by this permit. d. Design or construction deficiencies associated with the permitted work. e. Damage claims associated with any future modification, suspension, or revocation of this permit. 0 i X '� h� •/, iill 3. Reliance on Applicant's Data: The determination of this office that issuance of this permit is not contrary to the public interest was made in reliance on the information you provided. 4. Reevaluation of Permit Decision: This office may reevaluate its decision on this permit at any time the circumstances warrant. Circumstances that could require a reevaluation include, but are not limited to, the following: a. You fail to comply with the terms and conditions of this permit. b. The information provided by you in support of your permit application proves to have been false, incomplete, or inaccurate (see 3 above). c. Significant new information surfaces which this office did not consider in reaching the original public interest decision. 5. Such a reevaluation may result in a determination that it is appropriate to use the suspension, modification, and revocation procedures contained in 33 CFR 325.7 or enforcement procedures such as those contained in 33 CFR 326.4 and 326.5. The referenced enforcement procedures provide for the issuance of an administrative order requiring you comply with the terms and conditions of your permit and for the initiation of legal action where appropriate. You will be required to pay for any corrective measures ordered by this office, and if you fail to comply with such directive, this office may in certain situations (such as those specified in 33 CFR 209.170) accomplish the corrective measures by contract or otherwise and bill you for the cost. 6. When the structures or work authorized by this permit are still in existence at the time the property is transferred, the terms and conditions of this permit will continue to be binding on the new owner(s) of the property. To validate the transfer of this permit and the associated liabilities associated with compliance with its terms and conditions, have the transferee sign and date below. (TRANSFEREE -SIGNATURE) (NAME -PRINTED) (ADDRESS) (DATE) }}jrla17 el 10,1111 STANDARD MANATEE CONDITIONS FOR IN -WATER WORK 2009 The permittee shall comply with the following conditions intended to protect manatees from direct project effects: a. All personnel associated with the project shall be instructed about the presence of manatees and manatee speed zones, and the need to avoid collisions with and injury to manatees. The permittee shall advise all construction personnel that there are civil and criminal penalties for harming, harassing, or killing manatees which are protected under the Marine Mammal Protection Act, the Endangered Species Act, and the Florida Manatee Sanctuary Act. b. All vessels associated with the construction project shall operate at "Idle Speed/No Wake" at all times while in the .immediate area and while in water where the draft of the vessel provides less than a four -foot clearance from the bottom. All vessels will follow routes of deep water whenever possible. C. Siltation or turbidity barriers shall be made of material in which manatees cannot become entangled, shall be properly secured, and shall be regularly monitored to avoid manatee entanglement or entrapment. Barriers must not impede manatee movement. d. All on -site project personnel are responsible for observing'water-related activities for the presence of manatee(s). All in -water operations, including vessels, must be shutdown if a manatee(s) comes within 50 feet of the operation. Activities will not resume until the manatee(s) has moved beyond the 50-foot radius of the project operation, or until 30 minutes elapses if the manatee(s) has not reappeared within 50 feet of the operation. Animals must not be herded away or harassed into leaving. e. Any collision with or injury to a manatee shall be reported immediately to the FWC Hotline at 1 - 888-404-FWCC. Collision and/or injury should also be reported to the U.S. Fish and Wildlife Service in Jacksonville (1-904-731-3336) for north Florida or Vero Beach (1-772-562-3909) for south Florida. Temporary signs concerning manatees shall be posted prior to and during all in -water project activities. All signs are to be removed by the permittee upon completion of the project. Awareness signs that have already been approved for this use by the Florida Fish and Wildlife Conservation Commission (FWC) must be used (see MyFWC.com). One sign which reads Caution: Boaters must be posted. A second sign measuring at least 81/2" by 11" explaining the requirements for "Idle Speed/No Wake" and the shut down of in -water operations must be posted in a location prominently visible to, all personnel engaged in water -related activities. CAUT. 1 N,- MANATEE HABITAT All project vessel€ IDLE SPEED / NO WAKE When a manatee is within 50 feet of work all in -water activities must SHUT DOWN Report any collision with or injury to a manatee: . . . . Wildlife Alert. 1-888-404-FWCC (3J22) cel I * FVVC or #FWC .FILE COPY UNITED STATES DEPARTMENT OF COMMERCE National Oceanic and Atmospheric Administration NATIONAL MARINE FISHERIES SERVICE y Southeast Regional Office 263 13th Avenue South St. Petersburg, FL 33701 SEA TURTLE AND SMALLTOOTH SAWFISH CONSTRUCTION CONDITIONS The permittee shall comply with the following protected species construction conditions: a. The pernlittee shall instruct all personnel associated with the project of the potential presence of these species and the need to avoid collisions with sea turtles and smalltooth sawfish. All construction personnel are responsible for observing water -related activities for the presence of these species. b. The permi.ttee shall advise all construction personnel that there are civil and criminal penalties for harming, harassing, or killing sea turtles or smalltooth sawfish, which are protected under the Endangered Species Act of 1973. c. Siltation barriers shall be made of material in which a sea turtle or smalltooth sawfish cannot become entangled, be properly secured, and be regularly monitored to avoid protected species entrapment. Barriers may not block sea turtle or smalltooth sawfish entry to or exit from designated critical habitat without prior agreement from the National Marine Fisheries Service's Protected Resources Division, St. Petersburg, Florida. d. All vessels associated with the construction project shall operate at "no wake/idle" speeds at all times while in the construction area and while in water depths where the draft of the vessel provides less than a four - foot clearance from the bottom. All vessels will preferentially follow deep -water routes (e.g., marked channels) whenever possible. e. If a sea turtle or smalltooth sawfish is seen within 100 yards of the active daily construction/dredging operation or vessel movement, all appropriate precautions shall be implemented to ensure its protection. These precautions shall include cessation of operation of any moving equipment closer than 50 feet of a sea turtle or smalltooth sawfish. Operation of any mechanical construction equipment shall cease immediately if a sea turtle or smalltooth sawfish is seen within a 50-ft radius of the equipment. Activities may not resume until the protected species has departed the project area of its own volition. f. Any collision with and/or injury to a sea turtle or smalltooth sawfish shall be reported immediately to the National Marine Fisheries Service's Protected Resources Division (727-824-5312) and the local authorized sea turtle stranding/rescue organization. g. Any special construction conditions, required of your specific project, outside these general conditions, if applicable, will be addressed in the primary consultation. Revised: March 23, 2006 O:\fonns\Sea Turtle and Smalltooth Sawfish Construction Conditions.doc MAY 0 6 2011 FL, D,EFl PojzT Sr. LUe-jE VICINITY 100.01 Igo.al 100' 100.01 4', iluu.al 7 4 K ci 0— 100, joo .100 _10 0 100 loo.- JACKSOM WAY 100 100 100 LO -4 25 ems- r -3 100 loo 100 1100 169:38 L 0 C—A Tl' ON MA Richard L and Patricia M .Fiedler 912 1 Jackson Way Fort Plerce, FL 34949 ,27 co 100 'A o11 F PROP03ED. BULKHEAD MAP 5CAU�- Ak?ktp, scale,' DATE: 04122J.201 5HEET OF 3 5H.Et75 �F v EXISTING FENCE Coastal COV65 UnIt Lot 26 921 Jackson May LW15TIIVG CONCRETE .5EAWAU- PROPOSED BULKHEAD (PWATERWARD,OF EXISTING BULKHEAD) WA TER WA Y TO INDIAN RIVER EBB. / F.1009 - CANAL 1440TH /00".± MHW to MHW_ NOTES Q 25 % OF 100'(THEW�) IDTHOFTHEWATERWA=P5,: 25 ",9HALL REMAIN UN0'B'5TR''UCrED BYVOC?CS, MOORING OR DOLPHIN POLES, OR MOORED BOATS. 2) NO OD_9TRUC-T_1OAt5.5HALL_E)ffEAtD MORE THAN 40'(WITHIN OF CENTFRUNE OF WWERWA?) 3.) RENTING OF DOCKS, DOCK SPACE, OR MOORINGS OR.THE RENTAL OF BOATS FOR AAiypuRpo5e wHA t5oEvER t5 PRoHimm. Richard L and Pa trlcla M 1icdlcr 92 / Jackson Way .FortPierce, FL .34949 EXISTING PROPOSED BULKHEAD (I'WATERWAP—D OF 063TING.BULKHEAD) BULKHEAD PLAN ; ` 1 INFORMATION TAKEN FROM..5T. -LUCIE CoutvTY p"ROPERT-K APPRAISERS' oFj=tcE.mAps.5u,RvEyDr<AK,!,,,.,G PROPOSED BULKHEAD I RECEIVED 'MAY 0 62,011 FL REF PORT Si_ 4 UPF- .!5jffcT1ON VIEW SCALE- DEADMAN - 24'!X240X 120 EACH WAY (9 /O!MAX aci a .SEAWALL / BULKHEAD NEW WALL TO 6E PLACED WITHIN WATERWRD 0/` EXISTING WALL AfffTION BEST MANAGEMENTPRACTICES To BE USED 6GAte. -44' DURING CONSTRUCTION #7'BAR, IN PVC SLEEVE (MINIMUM I C NOTE.. LENGTH) i%// 2"DEND. 0 EACH.END ALL CONCRETE 3HALI BE 3000'PSI EXISTING -D ULXHEA D15EA WA L L i7OREMAIN IN PLACE) p STIRRUPS lNmur-S. 2411 o.c. 14" Mbfx fOn DEEP CONCRETE CAP wl (4)A4 OARS CON TINUOUS L A oll M/ Q Wl VINYL SHEETING MINIMUM 1: 1 PENETRATION INTO u., SANUY 501L ON CfNTER- WR R,� Pik- tk O.0 - R GH'CLJ �T "I 0 = DIAMETER CCA CHRMATEO OF F, COf T 'OER ARSENATE TE Richard and .Patricia M,Ftcdlcr 92 t Jackson way Fort Pierce, FL 34949 7 BUL)�H,�AD /- O'MAXIMUM, O.-C. DEADME-Al (BFYOND) 14"x 101.00AICRETECAp + E. SCALE._A5 NOTED DATE.;, - 041,22 20 11 SHEET 3 OF .3 514EET.5