Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSDATE: FEES OW: /,�, ( ►' f RECEIPT #: f7(//V qK_ I Permit #: 1-6 , U I IN Planning & Development Services Department - Building & Code Regulation Division V%_ 2300 Virginia Avenue Ft Pierce, FL 34982-5652 Tel. 772-4624553 4u, APPLICATION FOR ROOF P T a co'u' SEE REVERSE SIDEWOR INSTRyIjr"f10NS 1. Location/Site Addn 2. Parcel ID Number: Office Use Only I Section I Township Range Ma Page Zoning Land Use Initials a / 35- 0 a` (S" 3. Description of Projector Work Activity: Cr 1-1i^ct/% � 'eo oA poO, 4. Total Roof Area (square feet): /, 5. RoofPitch: / Z 6. Type of Roof: [ ] Fiberglass Shingle [ ] Concrete Roof Tile [ [ ] Tar & Gravel [Modified Bitumen [ ] 1 P [yroduct Approval required for all -types of Roofing Material (2 Sets) - /C,47 of ood Shake / Shingle Other [. ] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) With Product Approval attached ** Roof Mitigation per F.S. 553.844 will be required. 7. Owner Information / 8. Contractor Information Name: �liiY/ram V A 4"1 ROR i Address:?0�� °L- City: /� /� State: 1";L Zip: �y %c�� Phone: 9. Value of Construction: $ y�00, eo FL Reg/Cert #: 6r&, 6'95-2�F o / / County Cert #: I R �7 Business Name: Cell Phone: **Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval. CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all a uifo �in this li on i ct and that all work will be done in co th i IFI egulatu us tian d zoning. PRINT QUALIFIERS/OWNERS NAME OF QU R/O STATE OF FLORIDA, COUNTY OF ACKNOWLEDGED BEFORE ME THIS DAY OF 20_LL BY �VH PERSONALLY KNOMW O ME OR HAS Pk6DUCED *- K1- V 4, IJ AS IDENTIFICATION T�j SIGNA F N ARY ' E O RINT NAME OF NO �% ��' O �• ` a� COM ISSION NUMBER NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Revised 4/26/2010 .......... ••., AUIREY B. HUMPHREY a; MY COMMISSION #"p61159 a; EXPIRES., March 6, 2015 9onded Thru Notary Pubnc Underwriters gAf i •• a. S INSTRIXTIONS ' ' Please complete alhinformation in the space provided. All information must be printed (use black or blue ink only) or typed: This roof permit application is to be used only for those activities that are not otherwise included under a primary building •permit. This application may not be used for any activity that includes structural alteration. Building activities involving structural alteration, in addition to the roof work, must be permitted through4 lh regular building permit review process. The information to be provided with this application includes: 1. Location/Site Address 2. Parcel ID Number ' 3. Description of Project or Work Activity 4. Total Roof Area 5. Type of Roof 6. Owner Information 7. Contractor Information 8. Value of Construction Indicate the street address or general location of the property where the building activity is taking place. Indicate the tax identification number of the property where the building activity is taking place. Completely describe the building activity to take place. Please indicate if tear -off or shingle over shingle etc. Indicate total roof area to be affected by this permit. Also indicate the pitch of the roof, expressed as a standard ratio of run rise. Indicate the type of roof being. repaired or resurfaced. Indicate'the name and address of the owner of the property on which building activity is taking place. Indicate the State of Florida registration number (if applicable), St. Lucie County contractor license number and the name -of the business doing the work. Indicate the total value of the work to take place. Total cost of construction includes all material and labor costs associated with the building/construction activity. Construction value is used to determine the permit fee. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction. This. application can be submitted to St. Lucie County' Building and Zoning; 2300 Virginia Avenue, Fort Pierce, FL 34982. All permit applications must be-filled,out completely before submission. No applications will be accepted for processing after 4:30 P.k For assistance in completing this application, please call (772) 462-1553, during regular office hours (8 00 AM`- 5.00 PM), -Monday through Friday. Upon issuance of this permit, required inspections can be scheduled by calling (772) 462-1261. St Lucie County Roof Permit Application rev. 3/1/2009 JOSEPH E. SMITH, CLERK OF THE CIRCUIT COURT - SAINT LUCIE COUNTY FILE # 3599246 OR BOO]. ',99 PAGE 2025, Recorded 06/08/2011 afv—,,2:10 PM NOI'ICF OF COMMENCEMENT TO BE COMPLETED WHEN CONSTRUCTION VALUE EXCEEDS S2,500.00 PERMIT O: TAXFOLI00: 72/ g5laJ03 00"V1 STATE OF FLORIDA COUNTY OF?IAAa''+if �C c r P;E R� THE UNDERSIGNED HEREBY GIVES NOTICE THAT IMPROVEMENT WILL BE MADE TO CERTAIN REAL PROPERTY, AND IN ACCORDANCE WITH CHAPTER 713. FLORIDA STATUTES, THE FOLLOWING INFORMATION IS PROVIDED IN THIS NOTICE OF COMMENCEMENT. LEGAL DESCRIPTION OF PROPERTY(ANDSTREET ADDRESSI'/VAILABLEp y D�Sdt/�� �� .jZ✓�y ,QZ�AI zSi✓ X o"si iF�if r:.i r�, n> F /1 /s�si GENERAL DESCRIPTION OF IMPROVEMENT: / I_i)'%%f'`!�//�L. AE'<001-- OWNER NAME: ///A'R✓�� ✓ pl)I P✓1 D qo SZ ADDRESS �p tn; rJhZH 6 0'e7 / n / �A ;3�/ `f PHONENUMBF.R: 777 4Cr Ir of I $ FAX NUMBER. INTEREST IN PROPERTY: DC.c�NE.2 NAME AND ADDRESS OF FEES1�MPLL TITLE HOLDER (IF OTHER THAN OWNER): CONTRACTOR: L. OLUNS /("ODE/��C /N0 ADDRESS (LY PHONE NUMBER: 7, 7 .SCO/ / 3_n7 FAX NUMBER:' 77Z SURETY COMPANY (IF ANY): ADDRESS: I'AX NUMBER: PHONE NUMBER: BOND AMOUNT: LENDEWNIORTGAGE COMPANY: ADDRESS: PHONE NUMBER: FAX NUMBER: PERSONS WITHIN THE STATE OF FLORIDA DESIGNATED BY OWNER UPON WHOM NOTICES OR OTHER DOCUMENTS MAY BE SERVED AS PROVIDED BY SECTION 713.13 (1) (a) 7., FLORIDA STATUTES: NAME: ADDRESS: /1 PHONE NUMBER: _ FAX NUMBER: IN ADDITION TO HIM,,SS'ELF OR HERSELF, OWNER DESIGNATES NI —A OF I/� TO RECEIVE A COPY OF THE. L[G OR'S NOTICE AS PROVIDED IN SECTION 713.13(i)(B). FLORIDA STATUES. PHONE NUMBER: 411, FAX NUMBER: EXPIRATION DATE OF NOTICE OF COMMENCEMENT: (THE EXPIRATION DATE IS ONE (1) YEAR FROM THE DATE OF RECORDING UNLESS A DIFFERENT DATE IS SPECIFIED). WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OFTHE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON TI IS JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. i IG A E OF OW R O ER'S AUTHORIZED OFNICERIUIRF"CTOR/i'ARTNER/MANAGER SIGNATORY'S TITLEIOFFICE Gt THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME THIS 0 DAY OF %'k20 BY: / f I fjV (J, r S JL f 0 r'D AS AJ S U ftir1 Fox NAME OF PERSON 'TYPE OF AUTHORITY NAIVE OF PARTY ON BEHALF OF WHOM INSTRUMENT WAS EXECUTED PERSONALLY KNOWN,/ OR PRODUCED IDENTIFICATION,_ TYPE OF '6ENTIFICATION PRODUCED r " �: :�" ° a''•., ELIZABETH R. MOULTON T�} SIGNATURE e' f4ANotary Public - Slate of Florida % M ib%fiirAi9liT Imes A� UPlDER PENALTIES OF PERJURY, 1 DECLARE THAT 1 NAVE R' GO IN IT ARE TRUE'TO THE BEST OF MY KNOWLEDGE AND BELIEF (SECTI 2 ORIDA STATU ). 1(Slgn4*reof Natur erso Signing Above) STATE OF FIORV ST. L91E COUf�TY .c , : i ri()P tea THIS TRU Oil By: Daf P,IaMFhg & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 772_462=2165 of 772462-2172 Fax: 772-462-6443 Re: Permit# L"J,licensed as,(((n)(�Cointract�or��ngine.er/Architect , s4r (Please print name-& circle license type) "8-Befldi-ng Inspector *General, Building, Residential or Roofing Contractor or any individual certified under 468F.S. to make such an inspection. On or about I did personally inspect the roof deck nailing work at: (Job site address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S.) STATE OF FLCIRlp� COUNTY OF and bed bf subscribed this I r I by rcc License # 20j 0 is personally kno n to me or who has produced as wentaication. Notary -Public, State. of __, rida. Signature of Notary: Commission Number: En 01/19/2011 RECEIVED JUN 09 2011. P:_Pt)1C. W, ­1!� St. L F rs, v o C-1 v. Fl.. (Seal) ANGELA M. HUFF MY COMMISSION # EE 08=1 EXPIRES: April 12,2015 Bonded Thru Notary Public Underwrites IS Florida Building Code Onlim, 2 BCIS Home Log In , User Registration Hot Topics Submit Surcharge stats & Facts Publications 1 FBC Staff BCIS Site Map ( Links search l) ;1' Product Approval USER: Public User '00"ILE CVO'4�PY Product Approval Menu > Product or Application Search > Application List > Application tail FL # Application Type Code Version E - Application Status " Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) FL1654-R9 Revision 2007 Approved POLYGLASS USA 150 Lyon Drive THESE PLANS AND ALL PROPOSED WORK Fernley,FerNV 89408 (720) 279-2348 ARE SUBJECT TO ANY CORRECTIONS jarnold@polyglass.com REQUIRED BY FIELD INSPECTORS THAT Jim Arnold MAY BE NECESSARY IN ORDER TO jarnold@polyglass.com COW YAP" A!4mpwe"EEeeng. James Arnold, PE, RRO 10475 Park Meadows Drive Suite 600 Lone Tree, CO 80124 (720) 279-2348 jarnold@polyglass.com ST LUCIE COUNTY James Akins BUILDING SON 555 Oakridge Road Rom/ Fwm Humboldt Industrial Pkwy FO E Hazleton, PA 18201 (800) 894-4563 ��.� jakins@polyglass.com pl.l�N AND PERMIT MUST B KEPT ON JOB OR Roofing NO INSPE TION WILL BE MADE Modified Bitumen Roof Syste Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer �0I Evaluation Report - Hardcopy Received Robert Nleminen CONCEALED FASTENERS OR ATTACHMENTS PE-59166 ARE THE RESPONSIBILITY OF THE Underwriters Laboratories Inc. CONTRACTOR OF ArWMM 11/30/2012 l�'1'ftf96� �j j� John W. Knezevich, PE lam] Validation Checklist - Hardcopy Received FL1654 R9 COI Trinity ERD CI - Nieminen.pdf Standard Year ASTM D6163 2000 ASTM D6164 2000 hq : //www. floridabuilding. org/pr/pr_app_dtl. aspx?p aram=wGEVXQwtDgvgqu2w%2bnFg... 6/9/2011 Florida Building Code Online' 2 ASTM D6222 2002 FM 4470 1992 Equivalence of Product Standards Certified By Sections from the Code VILE COPY Product Approval Method Method 1 Option D Date Submitted 02/22/2011 Date Validated 02/23/2011 Date Pending FBC Approval 02/25/2011 Date Approved 04/05/2011 Summary of Products FL # I Model, Number or Name IlDescription 1654.1 Polyglass Modified Bitumen SBS and APP modified bitumen roof systems Roof Systems Limits of Use Installation Instructions Approved for use in HVHZ: No FL1654 R9 II Al er022211FINAL POLYGLASS MODBIT FL1654- R9.odf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-622.5 Created by Independent Third Party: Yes Other: 1.) The design pressure in this Evaluation Reports application relates to one particular assembly FL1654 R9 AE er022211FINAL POLYGLASS MODBIT FL1654- R9.pdf over concrete deck. Refer to the ER Appendix for other systems and deck types. 2.) Refer to Created by Independent Third Party: Yes ER, Section 5 for other Limits of Use. Back Next Department of Community Affairs Florida Building Code Online Codes and Standards 2555 Shumard Oak Boulevard Tallahassee, Florida 32399-2100 (850) 487-1824, Fax (850) 414-8436 © 2000-2010 The State of Florida. All rights reserved. Privacy Statement I Copyright Statement I Accessibility Statement I Plug-in Software I Customer Service Survey I Contact Us Product Approval Accepts: 0 ® -R-i M sccurit varlslon Tru�l�d � veeus� CONCELED FASTENERS OR ATTACHMENTS ARE THE RESpONS19111TY OF THE CORTRACTOR OF PFCOR.D hq://www. floridabuilding. org/pr/pr_app_dtl. aspx?param=wGE VXQwtDgvgqu2w%2bnFg... 6/9/2011 EXTERIOR RESEARCH & DESIGN, LLC, Certificate of. Authorization #9503 TRINITY I 353 Christian Street ERD Oxford, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 EVALUATION REPORT Polyglass USA, Inc. Evaluation Report P9290.02.08-R7 150 Lyon Drive FL1654-1119 Fernley, NV 89408 Date of Issuance: 02/11/2008 Revision 7: 02/22/2011 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code, The product described herein has been designed to comply with the 2007 Florida Building Code sections noted herein. DESCRIPTION: Polyglass SBS and APP Modified Bitumen Roof Systems LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinitylERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 5, plus a 30-page Appendl'3P'NCEAIEDFQSTEN RS ORATTACHMEM' Prepared by: Rug rqr ARE THE RESPONSIEIUTY OF THE CYN RACTOR OF RECORD rE The facsimile seal appearing was authorized by Robert Nleminen, P.E. on 02/22/2011 •'. p:,, ,� _ , • .� •:.f T ; This does not serve as an electronically signed Robert].M. Nleminen P.E. �;a` 9:�'' document. Signed, seated hardcopies have been / i :'y� ; �.� transmitted to the Product Approval Administrator and Florida Registration No. 59166, Florida DCA ANE1983 to the named client CERTIFICATION OF INDEPENDENCE: 1. Exterior Research & Design, LLC. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, .a financial interest in any company manufacturing or distributing products It evaluates, 2, Exterior Research & Design, LLC, d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being Issued, 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO 99kV WITH A6 A0PdgmhE B®BEs: APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE Table Deck Application Type Description TRINITY I ERD Page IA-1 Wood New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 4 IA-2 Wood New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 5 113 Wood New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 6 1C Wood New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 6 1D Wood New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 7 1E Wood New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 8-9 1F 33 ood New or Reroof Tear Off F � F �y Non-Insulated�Bonded Roof Coever ram;- 2A Steel or Conc. New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 10 2B Steel or Conc. New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 10 2C Steel or Conc. New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 11 3A-1 Concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 12-15 3A-2 Concrete New or Reroof (Tear -Off) A-1 Bonded Temporary Roof, Bonded Insulation, Bonded Roof Cover 16 3B Concrete New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 17 4A LWIC New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 18-19 4B LWIC New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 19 4C LWIC New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 20-23 5A CWF New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 24 5B CWF New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 25 5C CWF New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 25 SO CWF New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 26 SE CWF New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 26 6A Gypsum New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 27 6B Gypsum New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 28 6C Gypsum New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 28 6D Gypsum New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 28 �r 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 29-30 7B Various Recover F Non -Insulated, Bonded Base Sheet, Bonded Roof Cover 30 Exterior Research and Design, LLC. d/b/a TrinityjERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report P9290.02.08-R7 for FL1654-R9 Revision 7: 02/22/2011 Appendix 1, Page 1 of 30 VTRINITYIERD The following notes apply to the systems outlined herein: 1. Roof decks shall be in accordance with FBC requirements to the satisfaction of the AHJ. Wind load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Insulation Y base sheet fasteners shall be of sufficient length for the following deck engagement: ➢ Wood: Minimum 0.75-inch penetration. ➢ Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck. ➢ Concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions. 3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, DensDeck, DensDeck Prime, DensDeck DuraGuard, SECUROCK Gypsum -Fiber Roof Board or SECUROCK Glass -Mat Roof Board that meets the QA requirements of F.A.C. Rule 9N-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC 2603.4.1 or 2603.6, when installed with the roof cover. 4. Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D (mechanically attached base sheet, bonded roof cover), whereby the base sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. 5. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published instructions. ➢ HA (HA): Full coverage at 25-30 Ibs/square. ➢ Dow Insta-Stik Roofing Adhesive (D-IS): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. ➢ Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c. ➢ OMG OlyBond 500 or OlyBond500 Green (013500): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. (PaceCart or SpotShot). ➢ OlyBond Classic (OB Classic): Full coverage at 1 gal/square. ➢ 3M CR-20: Continuous 2.5-3.5-inch wide ribbons, 12-inch o.c. Note: TITESET may be used anywhere CR-20 is referenced. ➢ Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon -applied adhesive, adhesive ribbons shall be staggered from layer -to -layer a distance of one-half the ribbon spacing. ➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 6. Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations: ➢ Millennium One Step Foamable Adhesive (M-OSFA): MDP -157.5 psf (Min. 0.5-inch thick) ➢ OMG OlyBond 500 or OlyBond500 Green (013500): MDP -120.0 psf (Min. 1.0-inch thick) ➢ OMG OlyBond 500 or OlyBond 500 Green (OB500): MDP -90.0 psf (Min. 0.5-inch thick) ➢ 3M CR-20: MDP -117.5 psf (Min. 1.0-inch thick) 7. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft. 8. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117 and FM LPDS 1-29. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.1.5.1(a) of FM LPDS 1-29 for Zone 2/3 enhancements. 9. For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted. 10. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105 or ANSI/SPRI FX-1. Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report P9290.02.08-R7 for FL1654-R9 Certificate of Authorization #9503 Revision 7: 02/22/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 2 of 30 Pall r'�� 11�NTINI*ERD 11. For existing substrates in a bonded recover installation, the existing roof system shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the AHJ, as documented through field uplift testing in accordance with ASTM E907, FM LPDS 1-52 or ANSI/SPRI IA-1. 12. For Recover Applications using System Type D, the insulation is optional; however, the existing roof system shall be suitable for a recover application. 13. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications. Table 1: Polyglass Roof Covers Reference Layer Material Application BP -AA Base Polyglass G2 Base, Modibase, FBC Approved ASTM D4601, Type II HA 20-40 (Base and Ply sheets, at Asphalt -Applied) Ply FBC Approved ASTM D2178, Type IV or VI or ASTM D4601, Type II Ibs/square SBS-AA Base or Ply Elastobase, Elastobase Poly, Elastoflex V, Elastoflex S6 (SBS, Asphalt -Applied) Cap Elastoflex S6, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G, Elastoshield TS-G FR, Polyfresko HA at 20-40 Ibs/square MOP, Polyfresko MOP FR SBS-TA Base or Ply Elastoflex V, Elastoflex S6 (SBS, Torch -Applied) Cap Elastoflex V, Elastoflex S6, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G, Elastoshield TS-G Torch -Applied FR, Polyfresko MOP, Polyfresko MOP FR SBS-SA Base Elastoflex SA V Base, Elastoflex SA V FR Base, Elastoflex SA V Plus, Elastoflex SA V Plus FR (SBS, Self -Adhering) Cap Elastoflex SA P, Elastoflex SA P FR, Polyfresko SBS SAP, Polyfresko SBS SAP FR Self -Adhering APP-TA Base or Ply Polyflex, Polybond (APP, Torch -Applied) Cap Polyflex, Polyflex G, Polyflex G FR, Polybond, Polybond G, Polyfresko Torch, Polyfresko Torch FR Torch -Applied APP-SA (APP, Self -Adhering) Cap Polyflex SA P, Polyflex SA P FR, Polyfresko APP SAP, Polyfresko APP SAP FR, Polykool, Polybianko Self -Adhering 14. Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect on the system wind load performance. Refer to current Roofing Materials Directory for fire ratings associated with coating usage. ➢ PG200 Non Fibered Roof Coating or Mule -Hide 111 Non-Fibrated Roof Coating; ➢ PG300 Fibered Roof Coating or Mule -Hide 102 Fibrated Roof Coating; ➢ PG600 Non-Fibered Aluminum Roof Coating or Mule -Hide 416 Standard Non-Fibrated Aluminum Roof Coating; ➢ PG650 Fibered Aluminum Roof Coating or Mule -Hide 406 Standard Fibrated Aluminum Roof Coating; ➢ PG700 White Reflective Roof Coating; ➢ PG800 Non-Fibered Asphalt Emulsion Roof Coating or Mule -Hide 311 Emulsion Non-Fibrated; ➢ PG850 Fibered Asphalt Emulsion Roof Coating or Mule -Hide 301 Emulsion Fibrated; ➢ Polyplus 60 Premium Non-Fibered Aluminum Roof Coating or Mule -Hide 410 Premium Non-Fibrated Aluminum Roof Coating; ➢ Polyplus 65 Premium Fibered Aluminum Roof Coating or Mule -Hide 401 Premium Fibrated Aluminum Roof Coating; ➢ Polybrite 70 White Elastomeric Roof Coating. 15. The following represent priming requirements for gypsum -based coverboards: ➢ DensDeck and DensDeck Prime shall be field -primed with PG100 prior to self -adhering or torch -applied membrane application. No priming is required for hot -asphalt membrane applications. ➢ SECUROCK Gypsum -Fiber Roof Board or DensDeck DuraGuard do not require field priming for any membrane application. Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report P9290.02.08-R7 for FL1654-119 Certificate of Authorization #9503 Revision 7: 02/22/2011 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 3 of 30 `I TRINI7YIERD TABLE IE: WOOD DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System Base Sheet Roof Cover No. Roof Deck MDP (psf) Base Fasteners Attach Ply Cap Min. 19/32-inch plywood at 32 ga., 1-5/8-inch diameter 6-inch o.c. in 4-inch lap (Optional) One or W-30 max. 24-inch spans attached Elastobase or Elastobase Poly tin caps with 11 ga. annular and 6-inch o.c. in four, more BP -AA, SBS AA, 5B5- 112.5 6-inch o.c. with #8 screws ring shank nails equally spaced, SBS-AA, SBS-TA TA, APP-TA staggered center rows or APP-TA 32 ga., 1-5/8-inch diameter 6-inch o.c. In 4-inch lap (Optional) One or more SBS-SA (no Min. 19/32-inch plywood at Elastobase or Elastobase Poly with poly tin caps with 11 ga. annular and 6-inch o.c. in four, Elastoflex SA V SBS-SA, APP- W 31 max. 24-inch spans attached top surface ring shank nails. Note: Tin equally spaced, Base or Elastoflex SA, SBS-TA or 112.5 6-inch o.c. with #8 screws caps are to be primed with staggered center rows SA V FR Base), APP-TA PG100 or ASTM D41 primer. SBS-TA or APP-TA TABLE IF: WOOD DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE F: NON -INSULATED, BONDED ROOF COVER Roof Cover System No. Deck Primer MDP (psf) ]oint Treatment Base Ply Cap W-32 Min. 19/32-inch plywood at max. 24-inch spans attached 6- (Optional) PG100 None SBS SA (Optional) SBS-SA, SBS-SA, APP-SA,, gm inch o.c. with 8d ring shank nails _ SBS-TA or APP-TA SBS-TA or APP-TA g. iM�n. 19%32-Inch plywood at Plywood joints are covered with 4-inch Elastoflex SA V (Optional) SBS-SA SBS-SAAPP-SA W-33 max. 24-inch spans attached 6- (Optional) PG100 wide strips of Elastoflex SA V Plus, rolled Base or ElastElastoflex, SBS-TA or APP-TA , , SBS-TA or APP-TA -97 5 inch o.c. with #12 screws Into place to create continuous bond. SA V FR Base Min. 15/32-inch plywood at Plywood joints are covered with 4-inch Elastoflex SA V Plus (Optional) SBS-SA, SBS-SA, APP-SA, W-34 max. 24-inch spans attached 6- (Optional) PG100 wide strips of Elastoflex SA V Plus, rolled or Elastoflex SA V SBS-TA or APP-TA SBS-TA or APP-TA -135.0 inch o.c. with #12 screws into place to create continuous bond. Plus FR Exterior Research and Design, LLC. d/b/a TrinityJERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report P9290.02.08-R7 for FL1654-R9 Revision 7: 02/22/2011 Appendix 1, Page 9 of 30 :C;;' Polyglass, USA - Company that produces modified waterproofing membranes - Microsoft Internet Explorer pro... t a'v 2 http;/favwav2,polyglass.com,fjspsilinee_b.jsp?profile=ally, V d R Lnj polyglass app File Edit View Favorites Tools Help Favorites I , '� Home - St. Lude County Sh... 2 http--www.lebpe.com-4290... http--w"1w.lebpe.com-42901 Polyglass USA -Company that produces modified A,at.. � E Page Safety Tools �� » APP (Atactic Polypropylene) modified asphalt, roofing membranes, reinforced with polyester andlor fiberglass mat offering excellent tensile strength and dimensional stability. Products are manufactured for the commercial I industrial, and residential markets. ; �I Polybondlf) CI Polybond@ G CI Polyflexcq D Polyflex@ G CI Polyflex@ G FR O PolyglassO Base SBS (Styrene Butadiene Styrene) modified asphalt, roofing membranes, reinforced with polyester andlor fiberglass mat offering superior flexibility, excellent tensile strength and dimensional stability. Products are manufactured for the Q� Done I: L+ I, l I I internet 100% ' Thursday, Jun 09, 2011 02:01 PM Polyglass USA - Company that > �s modified waterproofing > • �;Iffx IMPv WJ http:fJa`wvv.,,2.polyglass.comfjsps/linee_b,jsp?profile=allFvr d d? �Google File Edit View Favorites Tools Help Favorites I Home -St. Lucie County Sh,,, http—www,lebpe,mm-4290,,, http—A1,,%,w,lebpe,com-42901 Polyglass USA -Company that produces modified wat,,, 'n ' Page + Safety - Tools - �Q;+ CI Polyflex(D G FIR O Polyglass(D Base MW SBS (Styrene Butadiene Styrene) modified asphalt, roofing membranes, reinforced with polyester andfor fiberglass mat offering superior flexibility, excellent tensile strength and dimensional stability. Products are manufactured for the - commercial I industrial, and residential market... 0- Elastobase(D U Elastotlexe S6 G FR [I ElastoflexcD S6 CI Elastoflex@ S6 G 1] ElasteshieldDTS G FIR S Elastoshield(,DTS, ElastoshieldOTS G CI PolyglassQ G2 Base °•LYGLASS; GROUP EUROPEANOPERATION Englisi, credits legal notes,,. .system:requirements map v 1J i �iit - 1 �' Done Internet L ' L Q 100%m r Thursday, Jun 09, 2011 02:31 PM -} 1m.L: . .. RX - File Edit View Bookmarks Tools Window Help ----� ❑❑ I� i? +( y Rr 4 ? 1:3.755 ;: MiD �❑ U l=`J JIF IC1 l—J 4, Parcel Boundaries l 4.70 @ ❑ Highlighter x O ❑Historic Sites r ~g,2827,B.t 2844 837gC ` ©+ Hydrology , * ❑ Annexations 2900" 2901 2900 [Z]Annexations O+ ❑ Zoning O+ ❑ Future land Use 'r ' 2905 2904 1816+:, '�''" O+ p ❑ Flood Zones ❑Petitions ;I t _29az iso6 ,mod iw+ O+ 298'�� El Airport Run -nay r . �., � , y►� ,•-t M' 28$_6 133 ❑ Parks &Preserves 2940' - 110` 285�7 ' O+ O+ ❑ Site Plans ry ❑ 1lindxones 2g50 _ "' r, 2913 �2912 s i 2889 50) "a n p O+ ElMobile Home Parks `�', , _ 2Q$�0' - ' 1$14 2891 1$06 p+ ❑ Subdivisions 2915 p O+ ❑ Solid Waste Service { R Major Hydrology 291;7 '-2916 21 24 ❑+ El Utility Service Area _ 2s8o� 429191 2918 d9. 4 4020 , 401'8 4016 .4014 4010 ' p+ O+ ❑ Zip Codes ", ❑ Municipalities 292,1 2920 2919 ., 402,: �• _ :� ,�'' - J 4 REE ®w R --., E8 2 Aerials 2009 x, 923 29 Q s: i 46Z1 4019 4b i 401:3 441- 4009: O+ i , r h ❑ Aerials 2006 II �• ❑ Aerials 2003 I a �. 2925' 924 3 2929- C 4028' ; } 930 4030 '4039 4041 4049° 4051; EO �: ti� _ - ■ 29 7rg, 4035 4045 L. , t 9f2926 229._ii : ,9� Finds features, places and addresses on the map ;', `:809068.98 1120296.66 Feet I, /;2q. q �d 49. i i 1I, Wednesday, Jun 08, 2011 02:21 PM Jul 10 11 12:14p Collins Roofing'!- )489-6505 p.2 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 Christian Street TRII'`r�I�iY ERD a L' ICE COS BUILDIl�IG� I®N Oxford, CT 06478 ST PHONE: (203) 262-9245 pre -Reviewed Not In Comp MC4 FAX: (203) 262-9243 EVALUATION REPORT 4Lw• = Polyglass USA, Inc. ��� `" Evaluation Rep P9290.02.08-R2 150 Lyon Drive DO- FL1654-R4 Fernley, NV 89408 Date of Iss ante: 02/11/2008 Revise 2:11/07/2008 SCOPE: This Evaluation Report is issued under Rule 9B-72 and the applicable rules and reg Ions governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been designed to comply with the 2004 & 2007 FBC. DESCRIPTION: Polyglass SBS and APP Modified Bitumen Roof Systems LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named products) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in Its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 5, plus a 33-page Appendix. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida OCA ANE1983 The facsimile seal appearing was authorized by Robert Nleminen, P.E. an L3107JZCOS This does not serve as an electronically signed document. Signed, sealed hardcoples have been transmitted to the Product Approval Adminlstrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Exterior Research & Design, LLC. d/b1a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entit y��valved in the approval process of the product. �Y �n.TG�l�i® ' STo LIJCIB C NOt c®gyp � Cq a U C m c 0 0 IY to C O U APPENDIX 1: ATTAINMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE Table Deck Application Type IA-1 Wood New or Reroof (Tear -Off) A-2 lA-2 Wood New, Reroof (Tear -Off) or Recover A-2 1B Wood New, Reroof (Tear -Off) or Recover D 1C Wood New, Reroof (Tear -Off) or Recover C 11D Wood New, Reroof (Tear -Old or Recover D 2C 2D-1 Steel or Conc. Steel or Conc. 2D-2 3A-1 Steel or Conc. Concrete 3A-2 Concrete 3F Concrete 4A LWIC 4B LW1C 4C LW1C 5A CWF 5B CWF 5C SD CWF CWF SE CWF 6A 6B 6C 6E 7A Gypsum Gypsum Gypsum Gypsum Various 711 Various New, Reroof (Tear -Off) or Recover New, Reroof (Tear -Off) or Recover New, Reroof (Tear -Off) or Recover New or Reroof (Tear -Off) New or Reroof (Tear -Off) ------------- New or Reroof (Tear-Ofr) New or Reroof (I -ear -Off) New or Reroof (Tear -Off) New or Reroof (Tear -Off) New or Reroof (Tear -Off) New, Reroof (Tear -Off) or Recover New, Reroof (Tear -off) or Recover New, Reroof (Tear -Off) or Recover New, Reroof (Tear -Off) or Recover New or Reroof (Tear -Off) New, Reroof (Tear -Off) or Recover New, Reroof (Tear -Off) or Recover New, Reroof (Tear -Off) or Recover Recover Recover Exterior Research and Design, LLC. d/b/a TrinitVIERD Certificate of Authorization 49503 Prepared by: Robert Nieminen, PE-59166 C D D A-1 A-1 F A-1 A-2 E A-1 A-2 B C E A-1 A-2 C E A-1 F TRINITY! ERD I Description Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover Mech. Attached Insulation, Bonded Roof Cover Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover Mech. Attached Insulation, Bonded Roof Cover Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover Prelim. Attached Insulation, Mech. Attached Roof Cover Bonded Insulation, Bonded Roof Cover Bonded Temporary Roof, Bonded Insulation, Bonded Roof Cover Non -Insulated, Bonded Roof Cover Bonded Insulation, Bonded Roof Cover Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover Bonded Insulation, Bonded Roof Cover Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover Mech, Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover Mech. Attached Insulation, Bonded Roof Cover Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover Bohhded Insulation, Bonded Roof Cover Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover Mech. Attached insulation, Bonded Roof Cover Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover Bonded Insulation, Bonded Roof Cover Non -Insulated, Bonded Base Sheet, Bonded Roof Cover Page 4-5 6 7 8 9 13 14 is 16-18 19 20 21-22 23 24-7.6 27 28 29 29 29 30 30 31 31 32 33 Evaluation Report P9290.02.08-R2 for rL1654-R4 Revision 2: 11/07/2008 Appendix 1, Page 1 of 33 L'WAYCI.PRmovNt MEna s omde l �e ApyT Coo %Uth % ApATali�allst> Appnwtfon oetnll FL tl (:2007 L1654-R7 Application Type evision - Code Version Application Status Approved Comments Archived Product Manufacturer POLYGLASS USA AddresslPhone/Email 150 Lyon Drive Fernley, NV 89408 (720) 279-2340 jarnold@)polyglass.com Authorized Signature llm Arnold jarnold0polyglass.com Technical Representative Chad Johnson Address/Phone/emall 621 SnivelY Avenue winter Haven, FL 33880 (866)802-801.7 Ext231 cjohnsonftolyglass.com Quality Assurance Representative James Akins Address/Phone/Email 55S Oakridge Road Humboldt Industrial Pkwy Hazleton, PA 18201 (800) 894-4563 jakins@polyglass.com Category Roofing Subcategory Modified Bitumen Roof System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Robert Nleminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity Underwriters Laboratories Inc. Quality Assurance Contract Expiration Pate 11/30/2012 Validated 6y ]ohn w, Knezevich, PE Certificate of Independence Validation Checklist - Hardcopy Received P1 1655- GOl Trinity FRr) rPrtir icon" of IndenrnriFncP.ndf Referenced Standard and Year (of Standard) Standard Vear ASTM D6163 2000 ASTM 06164 2000 ASTM D6222 2002 FM 4450 1992 9Ta frUcpa COMB�!U FM 4470 1992 AMA lu n aaa °. fit`<`r"•�' �� }..> USN6t - 9 1 of2 - - OG ,o 7/13/2010 2:06 PM 05-12-'11 17:01 FROM - T-147 P0005/0015 F-154 Equivalence or Product Standards Certified By sections rrom the code Date Submitted 02/05/2010 Date Validated 02/1212OLO Date Pending FBC Approval 02/24/2010 Date Approved 04/07/2010 PL # Model, Number or Name Description 1654.1 Polyglass Modified Bitumen SBS and APP modified bitumen roof systems Roof Systems _ Limits of use Installation Instructions Approved for use in HVHZ: NO Ft 1654 R7 11 Al 0rA7n51AF1NAL PQ YGLA55 Mr1nt1[T FL1654- Approved for use outside HVHZ: Yes BZ.RGt Impact Resistant: N/A Verified By: Robert Nleminen PE•59166 Design Pressure: +N/A/-522.5 Created by independent Third Party: Yes Other: 1,) The design pressure in this application rrvaluation Reports relates to one particular assembly over concrete FI t 6S4 R7 RcO: t1Sx9fi�At• Pc�t,XlaLA55�1C0DffLAA5A deck. Refer to the ER Appendix for other systems P2.9di and deck types. 2.) Refer to ER, Section 5 for other Created by Independent Third Party: Yes Limits of use. 9atk �Nekt Department of CommvnW AM(= Frorlds frulldlep Coda OARM Codes and Standard9 2SSS SlNmprd Oak 8001evdrd rd0f aMe, F10114a 32299.2100 (850) 489•1824, Fax (850) 414.8426 ® 2000•=010 the State of fblda. Al 69hts reserved. Pnu.ry sertemane I �,.=,���ane, �e,eems`S I a=p3sb r., � I okm cetaam I —r-Mor 1— _ e-, Jix I Product Approval AaMpl%t ®REE�E 7/13l?010 2:06 PM 2 ON Pr2dL"T Apomvol LI=? pjpdun orgorvrarwi sparrh y N? c. A0plicall Detail FL # FL5259-R5 Application Type Revision Code Version Application Status Approved Comments Archived r ' Product Manufacturer POLYGLASS USA Address/Phone/Email 15o Lyon Drive Fernley, NV 99408 (866)802-8017 Ext231 coohnson@ polyglass.com Authorized Signature Chad Johnson cjohnson@polyglass.com 7echnlcal Representative Chad Johnson Address/phone/Email 621 Snively Avenue Winter Haven, FL 33880 (866)802-8017 Ext231 cjohnson@ polyglass. com Quality Assurance Representative James Akins Address/Phone/Email 555 Oakrldge Road Humboldt Industrial Pkwy Hazleton, PA 18201 (800) 894-4563 jakins@ polyglass.com Category Roofing Subcategory underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer W7. Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who Robert Nleminen developed the Evaluation Report Florida License PE-59166 Quality Assurance Entity Underwriters Laboratories Inc. Quality Assurance Contthet Expiration Date 06/06/2010 Validated 8y John W. Knezevlch, Pr: FR Validation Checklist - Hardcopy Received Certificate of independence I Ei s 2 54 RS COI Trinity FRD c, - Ni miaem dff Referenced standard and Year (of Standard) fiLi3FLdaEd xg r ASTM D1970 2001 ASTM D226 1997 ASTM 06164 2000 http://Www.f!oridaboildiiig,org/pi/pr_app_dtl.asps+?paraln='c G*E-'VXQwtDgvbSLIAaZp3Crk... 4/27/2009 05-12-'11 17:01 FROM- T-147 P0007/0015 F-154 ASTM D5222 2002 ASTM G154 2000 ASTM G155 2004 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 02/26/2009 i Date Valldated 03/02/2009 Date Pending FBC Approval 03/11/2009 Date Approved 04/07/2009 Summary of Products FL # Model, Number or Name Descrlption 5259.1 Polyglass Roof UnderlaVments Roofing underla ments Limits of Use Installation instructionst FF o 's TT Pr022g09FINAL PCt1.YGLA.!�,z^ Approved for use in HVHZ: No Approved for use outside HVHZ1 Yes UN PRI A F 5254-RS.ndf Impact Resistant: N/A Verified By: Robert Nleminen PE-59166 Design pressure: +N/A/-135 Created by IndependentTh1fd Party: Yes Other: The design pressure In this application relates to evaluation Reports direct -bonding to plywood deck. Refer to ER Section 5 for F t:7a 5 AF Pr022409FINAI POLYGLAS3 ' olher limits of use. UNDtRI AYME R-RS.pdf Created by Independent Third Party: Yes DPGk NbMt OrA AdminlcNatlpp Department of Community AIIalrs Florida Huildln7 Codo Gatlne Codes) and Standards 2555 51jumard 0dk Boulavard "111hassee, FroGtla 32399.2100 (85p) 481-4924, FaX (OSO) 414-8496 0 2o00-2o05 The Stele of FloAda. All righw reserved. [ dnydnht ono Product Approval Accevt5l Cif vnratdn iOiVNd 'G' •��• reo�rr• http://ww.floridabuilding.org/pr/pr_app dtl.aspx?pal:am=wGEVXQwtDgvbSgAaZp3Crk... 4/27/2009 vv 05-12-'11 17:01 FROM- -1-14 r YlDIOl72S/ DIO1D r-.134 ERD certificate of Authorization #9503 OXFORD; CT 06478 FAX: (203) 2.62.9243 EVALUATION REPORT Polyglass USA, Inc: Evaluation Report P12060.02.09 150 Lyon Drive FL5259-RS Fernley, NV 98408 Date of Issuance: 02/24/2009 SCOPE: This Evaluation Report is issued under Rule 98-72 and the applicable rules and regulations. governing the use of construction materials in the State of Florida, The documentation submitted has been reviewed by Robert Nieminen, P.E, for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2007 Florida Building Code. DESCRIPTION: Polyglass Roof Underlayments LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE:. This Evaluation Report is valid until such time as the .named product(s) changes, the .referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change, Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrfnityJERD requires a complete• review of this Evaluation Report relative to updated Code requirements with each Code Cycle, ADVER,rYSEMENT: The Evaluation Report number preceded by the words 'Trinity)ERD Evaluated" may be displayed in advertising literature. 'If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official, This Evaluation Report consists of pages 1 through 8, Prepared by: i Robert 3.M. Nieminen, P.E. Florida Registration No. sgm, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nleminen, P.E. on 02/24/2009 This does not serve ns an electronically signed document. Signed, sealed hardcoples have been transmitted W the Product Approval AdminLtrator and to the named client CERTIFICA720N Of INDEPENDENCEC 1. T►InitylERD does not have, nor does it Intend to acquire or WIII it acquire, b rinanClet Interest in any company manufacturing or .distributing products it evaluates. 2. TrinitylIERD Is not owned, aperated Or Controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nleminen, P.E. does not have nor will acquire, a financial interest in any, company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 05-12-'11 17:01 FROM- T-147 P0009/0015 F-154 I rTR.INE` 1( ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have i demonstrated compliance with the following sections of the Florida Building Code (non-HVHZ) through testing in accordance with the following Standards. Compliance is subject to the Installation i Requirements and Limitations / Conditions of Use set forth herein. I Z. STANDARDS: Section Property Standard Year 1$07.2.4, 1507.2.9.2, 1507.3.3, Physical Properties (Polystick) ASTM 01970 2001 1507.5.3, 1507.6.3 1507.2,3, 1507.3.3, 1507.5.3, Physical Properties ASTM D226 1997 1507.7.3, 1507.8.3, 1507.9.3, (PolyProtector, Elastobase, 1507.9.4 Elastobase Poly) 1507.11,2 Physical Properties (Elastoflex ASTM D6164 2000 S6G) 1507.11.2 Physical Properties (Polyflex ASTM D6222 2002 G, Polyflex SAP) 1504.6 Accelerated Aging (Polystick) ASTM G154 2000 1504.6 Accelerated Aging (Polystick ASTM G155 2004 MTS, Elastoflex, Polyflex) 1504.3.1 Wind Uplift FM 4470 1992 3. REFERENCES: EEntiW Examination+ Reference Da to PRI (TST 5878) Physical Properties PRI01111 04/08/2= PRI (TST 5878) Physical Properties PUSA-005-02-01 01/31/2002 PRI (TST 5878) Physical Properties PUSA-013-02-01 12/23/2002 PRI (TST 5878) Physical Properties PUSA-013-02-02 12/23/2002 PFtI (TST 5878) Physical Properties PUSA-013-02-03 12/23/2002 PRY (TST 5878) Physical Properties PUSA-018-02-01 07/14/2003 PRI (TST 5878) Physical Properties PUSA-028-02-01 07/13/2005 PRI (TST 5878) Physical Properties PUSA-033-02-01 01/12/2006 PRI (TST 5878) Physical Properties PUSA-035-02-01 09/29/2006 PRI (TST 5878) Physical Properties PUSA-055-02-02 12/10/2007 PRY (TST 5876) Physical Properties PUSA-061-02-02 01/28/2008 PRI (TST 5878) Physical Properties PUSA-076-02-01 02/22/2008 PRI (TST 5878) Physical Properties PUSA-083-02-01 04/14/2008 MT1 (TST 2508) Physical Properties ]X201­17A 04/01/2008 MTI (TST 2508) ERD (TST 6049) Physical Properties Physical Properties RX14E8A 11752.09.99.1 Ol/29/2009 02/08/2000 ERD (TST 6049) Physical Properties 02200.07.03 07/14/2003 ERD (TST 6049) Physical Properties P5110.04.07-1 04/i1/2007 ICC-ES (EVL 2396) IBC Compliance ESR-1697 01/01/2005 ICC-ES (EVL 2396) IBC Compliance ESR-1160 03/01/2005 Miami -Dade (CER 1592) HVHZ Compliance NOA Current Polyglass USA Manufacturing Affidavit Products Current 02/18/2009 UL (QUA1743) Quality Control File No. R14571, Vol 1 Exp. 03/21/2010 Exterior Research and Design, LLC. Evaluation Report P12060.02.09 certificate of Authorization #9503 FL5Z59-R5 Date of Issuance: 02/24/2009 Page 2 of 8 05-12-' 11 17: 02 FROM- T-147 P0010/111015 r-154 ERD 4. PRDDUCT DESCRIPTION: 4.1.1 PoLYPROTECTOR UDL is a polyoleflnic, multi -laminated roof underlayment coated with a UV formulated skid resistant protective layer meeting the performance requirements protective and of an ASTM D226, Type II felt. 4.1.2 ELASTOBASE Is a fiberglass reinforced, SBS modified bitumen base sheet meeting the performance requirements of an ASTM D226, Type II felt. 4.1.3 EusTOBASE POLY is a polyester reinforced, sBS modified bitumen base sheet meeting the performance requirements of an ASTM D226, Type II felt. 4.2 Self -Adhering UnderlaYments: 4.2.1 poLysr%cK MTS is a rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced with polyclefinic film surface (ASTM 01970) 4.2.2 PoLYsTicK IR-Xe is a rubberized asphalt waterproofing membrane, glass fiber reinforced, with a sand surface (ASTM D1970). . 4.2.3 PoLYsruK TU is a rubberized asphalt waterproofing membrane, glass fiber reinforced, with a granular surface (ASTM D1970). 4.2.4 P0LY5rIcK7U Plus is a rubberized asphalt waterproofing membrane, glass fiber reinforced, with a high strength polyester fabric surface (ASTM D1970). 4.2.5 POLYSTICKTU P is a rubberized asphalt waterproofing membrane, glass-fiber/polyester reinforced, with a granular surface (ASTM D1970). 4.2.6 POLYFLEX SAP is a polyester reinforced, APP modified bitumen cap sheet (ASTM D6222). 4.3 Mec-hp.Vically Fastened and/or 1#nndad Underla_yment£ 4.3.1 ELASTOFLEx S6G is a polyester reinforced, SBS modified bitumen cap sheet (ASTM D6164). 4.3.2 POLYFLEx G Is a polyester reinforced, APP modified bitumen cap sheet (ASTM D6222), 5. LIMITATIONS: S.1 This Evaluation Report is not for use in the HVHZ. 5.2 Fire Classification Is not part of this Laboratory Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.3 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the AHJ for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.4 Allowable roof covers applied atop the underlayments are follows: Table S, Roof Cover Options Asphalt Foam -on Metal Wood ShaKes slate Nail -On Tile Tile a Shingles Underlaylnent Shingles PolyProtector UDL Yes Yes No Yes Yes Yes elastobase Yes Yes No Yes Yds Yes Elastobase P Yes Yes No Yes Yes Yes Polystick MT5 Yes Yes No Yes Yes Yes Polystick IR-Xe Yes Yes No No Yes Yes Exterior Research and Design, LLC. Certiricate of Authorization OF9503 Evaluation Report P12060.02.09 FL5259-R5 Date of Issuance: 02/24/2009 Page 3 Of 8 v.i 1G. 11 1 ( . 1UG rnurl- T-147 F0011/0015 F-154 E `Y Vable i s Roof Cover Options Underlaymant Asphalt ShingleS Nall -On Tile Foam -On Tile Metal Wood Shakes Shingles Slate Polystick TU Yes Yes Yes No Yes, Yes Polystick TU P Yes Yes Yes NO Yes Yes Polystick TU Plus Yes Yes Yes Yes Yes Yes Elastonex SGG Yes Yes NO No Yes. Yes Palyilex G Yes Yes No No Yes Yes Polyllex SAP Yes Yes No No Yes Yes 5.4.1 PolyProtector UDL, Elastobase and Elastobase Poly may be used as a mechanically attached base layer followed by a Polystick or Polyflex SAP top layer with allowable roof covers noted above for the respective Polystick or Polyflex SAP underlayments. 5.4.2 Elastobase and Elastobase Poly may be used as a mechanically attached base layer followed by a Elastoflex S6G in hot asphalt oi- Polyflex G top layer with allowable roof covers noted above for the respective Elastoflex.S6G or Polyflex G underlayments, 5.4.3 "Foam -On Tile" is limited to use of Polyfoam Polyset applications unless data from an accredited testing laboratory for alternate foam -adhesive with the subject underlayment in accordance with ICC-ES AC152 Is provided. 515 For mechanically attached metal and nail -on -tile systems, underlayment system consisting of Polystick MTS followed by Polystick MTS, TU, TU P or TU Plus is permissible. S.6 'Allowable substrates for self -adhering underlayments are noted below: 5.6.1 Polystick or Polyflex SAP Direct -Bond to Deck: 9 ASTM •D41 primed structural concrete; OSB; Southern Yellow Pine; New untreated plywood; Existing plywood primed as needed per inspections by Polyglass; ASTM C1289, Type II, Class 1 polyisocyanurate or Type V composite insulation (designed and installed to meet wind loads for project); S.6.1.1 The maximum design pressure for direct -bond Polystick applications to plywood or primed plywood is -135 psf. This is pertinent for foam -on tile systems and situations where the underlayment will be exposed through a hurricane season. For other substrates, consult Polyglass USA, Inc. 5.6.2 Polystick or Polyflex SAP Bond to Mechanically Attached Base Underlayment: )> ASTM D226, Type I or II felt; ASTM 04869 felt; ASTM D2626 base sheet; PolyProtector UDL; Elastobase; Elastobase Poly, 5.7 Exposure Limitations: 5.7.1 PolyProtector UDL, Elastobase, Elastobase Poly shall not be left exposed for longer than 30- days after Installation. 5.7.2 Polystick IR-Xe shall not be left exposed for longer than 90-days after installation. 5.7.3 Polystick MTS, TU, TU P, TU Plus, Elastoflex SGG, Polyflex G and Polyflex SAP shall not be left exposed for longer than 180-days after installation. Exterior Research and Design, LLC. Evaluation Report P12060.02.09 certificate of Authorization V9503 FL5259-RS Date of Issuance: 02/24/2009 Page 4 of 5 05-12-'11 17:02 FROM- T-147 P001Z/0015 F-154 I 5.8 S.El. 1 '�1TR .EAD For the roof Installations governed by the FRSA/TRI 07320/8-05 Installation Manual, Fourth Table 2; The System Options for Polyglass Roof Underlayments per FRSA/TRI 07320/8.05 System • Underlay Section Reference Polyglass Product(s) option I 3.02A Modified Cap Sheet Elastoflex 566 or Polyflex G Elastobase or Elastobase PolV / Elastoflex 2 3.028 No. 30 / Modified Cap Sheet 56G or Polyflex G g SMtam nnh; 3.02C No. 30 / Modified Cap Sheet Elastobase or Elastobase Poly / Elastoflex Mechanically 3 56G PolyProtector UDL, Elastobase or Fastened Tile,. unsealed or 4 3.021) No, 30 Elastobase Poly Sealed Underlayment 5 3.02E Self -Adhered Underlayment Polystick MTS, IR-Xe, TU, TU P or TU Plus or PolyflaX SAP System PolyProtector UDL, Elastobase or . 30 / Self -Adhered No. 30 No Elastobase Poly / Polystick MTS, IR-Xe, TV, 6 3.02F a meet Y TU P or TU Plus or Polyflex SAP I 3.02A Modified Cap Sheet Elastoflex 56G or Polyflex G ' Elastobase or Elastobase Poly / Elastoflex 2 3,028 No. 30 / Modified Cap Sheet 56G or PolyflCX G 5, stem TWO: Elastobase or Elastobase Poly / ElastoflaX Mechanically 3 3.02C No. 30 / Modified Cap Sheet S6131 Fastened Tile, Sealed Polystick MTS, IR-Xe, TV, TU P or TU Plus Underlayment 4 3.O70 Self -Adhered Underlayment or Polyflex SAP System polyProtector UDL, Elastobase or No. 30 / Self -Adhered Elastobase Poly / Polystick MTS, IR-Xe, TU, 5 3.02E Underlayment TU P or TU Plus or Polyflex SAP Syct�m Four 2 3.02B No. 30 Elastobase or Elastobase Poly 4 3.02D Self -Adhered Underlayment Polystick TU, TU P Or TU Plus Adhesive -Set Tile, Unsealed PolyProtector UDL, Elastobase or or Sealed 3D2E No. 30 / Self -Adhered Elastobase Poly / Polystick MTS, fR-Xe, TU, Underlayment g . Underlayment TU P or TU Plus System 1 3.O2A No. 30 Elastobase or Elastobase Poly FOIE[ System 3 3.02C $eif-Adhered Underlayment Polystick TU, TU P or TU Plus AdheS'ye-Set PolyProtector UDL, Elastobase or Tile, Sealed No. 30 / Self -Adhered Elastobase Poly /Polystick MTS, IR-Xe, TU, Underlayment 4 3.OZD Underlayment TU P or TU Plus System Note: Polyglass defers to the tile manufacturer on use of their tiles directly over its underlayments. Exterior Research and Pesign, LLC. certificate of Authorization *9503 Evaluation Report a12060.02.09 FL5259-RS Date of issuance: 02/24/2009 Page 5 of 8 t; 05-12-'11 17:02 FROM- T-147 P0013/0015 F-154 G. INSTALLATION: 6,2 6.3 6.3.1 6.3.2 6,3,2.1 6.3.2.2 6.3.2.3 i . 6.4 6.4.1 6.4.2 6.4.2.1 6,4.2.2 6.4.3 ERa volygidsu r%UVI vlwvaloyn.cnw anon ..... _........ ... ----------- installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). p�lyProtector UdL:- Shall be installed in compliance with the requirements for ASTM D226, Type II underlayment in FBC sections 1507 for the type of prepared roof covering to be installed. For use In non -tile applications: The minimum slope shall be 2:12. Where the slope is 2:12 up to 4:12, the underlayment shall be installed in two layers. The underlayment shall be laid horizontally (parallel to eave) starting at the lowest point, printed side up, with minimum 3-inch horizontal (head) laps and 6-inch vertical (end) laps. Overlaps shall run with the flow of water in a shingling manner, The underlayment shall be attached to the roof deck using plastic or metal cap nails having minimum 1-inch head diameter spaced 6-inch o.c. at head and end laps, and 12-Inch o.c. vertically and horizontally in a staggered pattern in the field of the sheet. PolyProtector UDL may be covered with a layer of Polystick or Polyflex SAO. For use in tile applications, reference is made to Rolyglass published Installation instructions in conjunction with FRSA/TRI 0732018-05 Installation Manual,, fourth Edition, and Table 2 herein. Elastobase_nr Elastobase pnly: shall be installed In compliance with the requirements for ASTM D226, Type II underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. For use in non -tile applications: Reference is made to the current edition of the NRCA Steep -slope Roofing Manual and ARMA recommendations for installing shingle underlayments and flashings Elastobase or Elastobase Poly may be covered with a layer of Polystick, Polyflex SAP, E(astoflex S6G in hot asphalt or Polyflex G, torch applied. For use in tile applications, reference is made to Polyglass published installation instructions in conjunction with FRSA/TRI 0732018-05 Installation Manual, Fourth Edition, and Table 2 herein. Evaluation Report.012060.02,09 Exterior Research and Design, LLC. FL5259-R5 certificate of Authorization 99503 Date of Issuance: 02/24/2009 Page 6 of 13 1 -14 f r VJrJ.L-if VV-L� 05712-' 11 17: 02 FROM- 6.5 a!YSnLK 1" 1 Sections 1507 for the type of prepared roof covering to be installed. '6.5.2 For non -tile applications: _ lass. Mails 6.5.2.1 All Polystick materials, with hglass Bacl� NallingoGuide published at www2 P IlYstick TU plus, should be y91< nailed in selvage edge seam a p Y diameter metal shall be corrosslo resistantat a gauge ring-shank imum of 1Z`ee c. Po Ysti k TU1plus hsho d be back - disk or Simplex-typeback- nailed using the above noted fasteners and spacing, In area marked "nail area, area pa a clavar" on the face of membrane. The head lap membrane is to cover the area being nailed st be firmly rolled with a hand roller to ensure full 6.5.2.2 All seal lap seams (selvage laps) mu contact.h wide, orm lass 6.5.2.3 All over -fabric and over -granule end -lap shall have a volyglasscPolyplus 50 Premium MBPFIa hing Polyplus 55 Premium Modified Flashing Cement, Polyglass pG500 Me Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wdt/Dry Electrome,nFlashing Cemthe ent,appor Mine -Hide the lap 1 Mod Bit Flashing Adhesive Trowel Grade mastic, applied 6.5.2.4 Polystick TU Plus may not all details n any exposed application such as crickets, exposed valleys, or exposed roof to ,n Polyglass Polyplus 55 lus 50 Premium MB Flashing Cement, 6.5.2.5 Repair of Polystick membranes is to be accomplished by apply 9 Premium Modified Flashing Cement, Polyglass P01ypdified Polyglass PG500 MB Flashing ry Cement muericilFde 241 Premium lash ng Cement oro Mule-H deh421 Mod eBit nimum 6 Mule -Hide 251 Premium Wei/Dryof reFlashing Adhesive Tr ewPaGstc k material of likeea in kind,� s t and ha1ndf lolled an Places over the x 6 inch patch of the Y in a water shedding manna repair area. Patch Paps, if needed, shall be installed re full contact with approved substrates. 6.5.2.6 • All Polystick membranes shall be installed to ensusteep Polyglass requires a minimum of 40-lb weighed for lthe er ofield nmembrane. peHand rollers are broom with approximately 40-Ibs of load applied of patches, laps or small areas of the roof that are not accessible to a acceptable for rolling large roller or broom. 6.5.3 For the applications: S.2 herein in • 6.5.3.1 Reference is made to Section � and Table 2 herein, Iusing the instruunction with ct-ions noted above as Installation Manual, Fourth a guideline. 6.6 Elast flex 56G an Pol flex 6.6.1 For use in file applications, reference is made to Polyglass published installation Instructions in conjunction with FRSA/TRI 07320/8-05 installation Manual, Fourth Edition, and Table 2 herein. Exterior Research and Design, LLC. Certificate of Authori,,atlon 49503 F,ualuation Report PL 0.02.09 FL5a59-1t5 Date of xrsuance:. 02//24/2 009 Jul 10 11 12:14p Collins Roofing, Inc (77)489-6505 p.1 GL��5�3�v 20 1' d a Ln O) k" u CL u7 04 0 75 TRINITY , ERD TABLE 1E: WOOD DECKS - NEW CONSTRUCTION or REROOF (Tear -Off) j SYSTEM TYPE E; NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System Base Sheet No. Roof Deck Roof Cover Base Fasteners Attach Ply cap MDP (psf) 32 ga., 1-5/8' diameter tin g" o.c. in 4" lap and 6" Min. 79/32" plywood at max. EI®stobase or ElasLobase Poly with caps with 11 ga. annular ring W-31 24" spans attached 6' o.c. Y p01y o.c. in four, equally (Optional) One or SB5-5A or tep surface shank nails, Note: Tin caps spaced, staggered more SBS-SA APP-SA -112.5 with #8 screws are to be primed with PG100 or ASTM D41 primer. center rows TABLE IF; WOOD DECKS - NEW CONSTRUCTION or REROOF (Tepr-Off) „ SYSTEM TYPE F: NON -INSULATED, BONDED ROOF COVER System No. Deck Primer Roof Cover Base Ply Cap MDP (psf) Min. 19/32" Plywood at �— max. 24" - W-32 spans (Optional) PG 0 SBS-SA attached 6" (Optional) SOS -SA SBS-SA r APP-SA -90.0 rig shankd nails Exterior Research and Design, LLC. d/l,/a TrinitylERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report P9290.02.09-R2 for FL1654-R4 Revision 2: 11/07/20DS Appendix 1, Page 11 of 33 CL 1 O 0) 00 U c of c 0 0 W N c k a LD N O 75 TRINITY i ERD 11. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications. Table 1: Polyglass Roof Covers Reference BP -AA (Base and Ply sheets, Asphalt -Applied) Layer Base Material Polyglass G2 Base, Modlbase Application Hot asphalt at 20-40 Ibs/square Ply ASTM D2178, Type IV or V3 SBS-AA (SBS, Asphalt -Applied) Base or Ply Elastobase, Elastobase Poly, Elastoflex V, Elastoflex S6 Hot asphalt at 20-40 Ibs/square Cap Elastoflex S6 ,Elastoflex S6 G, Elastoflex S6 G fR, Elastoshleld 75-G, Elaslosliield TS-G FR, Polyfresko MOP, Polyfresko MOP FR SBS-TA (SBS, Torch -Applied) Base or Ply Elastoflex V, Elastoflex SG 1 orch-Applled Self -Adhering Cap Elastoflex V, Elastoflex VG, Elastoflex VG FR, ElaStoflex S6, Elastoflex 56 G, Elastoflex S6 G FR, Clastoshield TS-G FR, Polyfresko MOP, Polyfresko MOP FR SBS-SA (SBS, Self -Adhering) Base Elastoflex SA V, E.0stoflex SA V FR Cap Elastoflex SA P, Elastoflex SA P FR, Polyfresko SBS SAP, Polyfresko SBS SAP FR APP-TA (APP Torch -Applied) PP ) Base or Ply Polyflex, Polybond Torch -Applied Cap Polyflex, Polyflex G, Polyflex G FR, Polybond, Polybond G, Polyfresko Torch, Polyfresko I orch FR APP-SA (APP, Self -Adhering) Cap Base �olyfl�SAP,lyflex SA P FR, Polyfresko APP SAP, Polyfresko APP SAP FR, Polykool, Polybianko Xtraflex Self -Adhering TPO-TA (TPO, Torch-Applled) Torch -Applied Cap Xtraflex, Xtraflex G, xtreflex G FR 12. Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect on the system wind load performance. Refer to current Roofing Materials Directory for fire ratings associated with coating usage. D PG200 Non Fibered Roof Coating or Mule -Hide 111 Non-Fibrated Roof Coating; P, PG300 Fibered Roof Coating or Mule -Hide 102 Fibrated Roof Coating; D PG600 Non-Fibered Aluminum Roof Coating or Mule -Hide 416 Standard Non-Fibrated Aluminum Roof Coating; A PG650 Fibered Aluminum Roof Coating or Mule -Hide 406 Standard Fibrated Aluminum Roof Coating; D PG700 White Reflective Roof Coating; 31, PG800 Non-Fibered Asphalt Emulsion Roof Coating or Mule -Hide 311 Emulsion Non-Fibrated; ➢ PG850 Fibered Asphalt Emulsion Roof Coating or Mule -Hide 301 Emulsion Fibrated; D Polyplus 60 Premium Non-Fibered Aluminum Roof Coating or Mule -Hide 410 Premium Non-Fibrated Aluminum Roof Coating; Polyplus 65 Premium Fibered Aluminum Roof Coating or Mule -Hide 401 Premium Fibrated Aluminum Roof Coating; Ir Polybrite 70 White Elastameric Roof Coating. Exterior Research and Design, LLC. d/b/a TrhiitylERO Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report P9290.02.08-R2 for FL1654-R4 Revision 2: 11/07/2008 Appendix 1, Page 3 of 33