HomeMy WebLinkAboutSUBMITTED PAPERSDATE: �� _ ( PERMIT NUMI - C1 U
= PLANNING & DEVELOPMENT SERVICES DEPARTMENT
o BUILDING & CODE REGULATIONS DIVISION
® 2300 Virginia Avenue
Fort Pierce, FL 34982 sC
(772) 462-1553 `q
Sf �� BYNFO
APPLICATION FOR REPLACEMENT OF e C
WINDOWS, SKYLIGHTS, DOORS & OVERHEAD GARAGE DOORS Oo�fir
LOCATION/SITE ADDI
2. PARCEL ID NUMBER:
3. DESCRIPTION OF PROJECT OR WORK ACTIVITY:
4. TYPE OF STRUCTURE: SFR
MOBILE HOME
5. OWNERS INFORMATION 6.
e
Name: L
Address: y r70 -7 MC nC61 1Q.
UA
City: P ��(�� State:
Zip: Phone: Wo L 1
OTHER
CONTRACTOR'S INFORMATION
FL Reg/Cert #•
County Cert #: '
Business Name•
PhoneNumber:
Windows, Swing Doors,
Skylights, Fixed Glass
Opening Design Pressure
A.S.C.E - 7
Design
Pressure
Product
Manufacture
Model #
Method of Attachment #
Florida Product Approval #
120 mph
30 mph
1140 mph
Windows & Skylights
Exposure B
Exposure C
Overhead Garage Doors
< 30' - F.B.C. Table 1609.6 (1) + 1609.6 (2)
J
7. VALUE OF CONSTRUCTION: $ In�S FEES DUE: �- CD
RECEIPT:lJ�
OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in
compliance with all applicable laws regulating construction and zonin .
PRINT QUALIFIERS70WIERS NAME SIGNA OF Q IFIER/OWNER
STATE OF FLORIDA, COUNTY OF t 1
ACKNOWLEDGED BEFORE ME THIS DAY OF 20 BYCCIO(HOISRSONALLY KNOWN TO ME R WHO
HAS PRODUCED AS IDENTIFICATION.
SIGNA OTARY TYPE OR PRINT NAME OF NOTARY
TITLE: NOTARY PUBLIC COMMISSION NUMBER �) 99-
NOTICE TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING
�;W.A TERESAMUNSON
MY COMMISSION # DD 9W73
EXPIRES: May 18, 2014
• Bonded Ttn Notary Pubk Underwriters
I
f 1ICIr1o•
FIL�OPY
Field Survey
Date: �•-
�'1
Customer:
Phone: ,4/&
Owner:--] it, ciic^ ' -:
Phone:
Address; ' �� t
\ , 1
Fax:
�-s� �—
Cell:
W x H
MFG
Model
Zone
Exp.
Design P.S.F
Test P.S.F
X
v
+�-I .7
-_
x
Wall Construction
Vertical Jambs
Header
Spring Pad
CMU - Wood / Other
C
(+ C
Required Anchors
# 1 C Below
Wood Jamb Attachment To Structure
( # 1) For attachment of jambs to cast in place concrete, Use 3/8" x 5". Install bolts a maximum
of 6" from each end and at i,301on center. Anchors must have a minimum of 2-1/2" embedment into concrete.
(# 2 ) For attachment to hollow block, use 1/4" diameter tapcon anchors. Install a pair of anchors a
maximum of 6" from each end and a pair at 12" on center. The pair of anchors should be approximately
3" center to center. Anchors must have a minimum of 1-1/4" embedment into hollow block.
( # 3 ) Attach tracks to wood frame with " x " lags & additional track brackets (aa iequirdd)
to secure thru existing it x it jamb with minimum of 1 1/2" embedment into existing stud wall.
Existing
Wall
FLOOR PLAN
INTERIOR
CMU
Existing
Wall
STRUCTURAL 01-E8lGN
- TABLE 11 509.6(1)
GARAGE DOOR AND ROLLING DOOR WIND LOADS FOR A BUILDING WITH
A MEAN ROOF HEIGHT OF 30 FEE7 LOCATED IN EXPOSURE B (pso
Basic Wind Speed V (mph - 3 &acond gust)
110 1 120
i 130
1
150
- -- - - -
Roof Angie 0 - 10 decrees
C'. 5 1 -19.9 i
I 6A -23.6
20 9
24. 5
-27.7 28.4
-32.2
32.6 16 9
4 4.0 9.0 M2 -22.7 i
23.7,
.26.6 27.5
-30.8
31.6 .35
1
0 :0 .8 -14.8 16..9 9.2 -21.4
22.5
-25.1 26.1
-29.1 30.0 33
Roof ArZJe > 10
V
A
9 2-8 8 7.9 19. i -21.6 22.8 .25.8
26.7
3, 0. 2 I 31.0
.35.1 I
35.6
2, 2.3 3. 6.9 i 18.3, - 2 0. 21.8 -24.3 125.6
I
-28
34 1
Sq.j:fc 'rC)01 zi"
SI
'�r29 rf!" Mph 0. 4.: 7 , r,,js• i ps 47.88 1,Ij-n 1
c areas 6
t.")
•IZ:c •V.C� shal! be I
Os-c given above J;c load may be otherwise use
C. --S;qd ro.'
the load
associated with
the ;o-cr
c.'(cct.-c area
I
height and cxposu. c by multi !yin by adjusun'cni coot r-icicn;s ir, Table 1609.60).
P., Pressures acting toward and aw:., from the building surfaces.
as :cot o width ; M building's end Zone.
TABLE 1609.6(2)
ADJUSTMENT FACTOR
FOR BUILDING HEIGHT AND EXPOSURE,,(;i',
A-'q ROOF 4EIGH.-F
EXPOSURE
ee I)
MAMM
c
-----------
1.29
-
T
00
7-
1
1.35
Y
1.40
---------------
!.09
--
1.49
12
!.53
!.!6
1.56
60
9-.-
1.59
..22
'.62
adjul: O'd For oihc, Cxposui-es
ard ui!;PlY;ng by
te above coefficier[S.
A
1.47
1.55
1.61
!.66
1.70
1.74
.78
1.8 1
1.84
1 ..87
---- - --I- . -1 ... -.- -^-c =,M n;r rl
MAW
NQADE
BUILDING CODE COMPLIANCE OFFICE (BCCO)
PRODUCT CONTROL DIVISION
MIAMI-DADS COUNTY, FLORIDA
METRO-DADE FLAGLER BUILDING
140 WEST FLAGLER STREET, SUITE 1603
MIAMI, FLORIDA 33130-1563
(305) 375-2901 FAX (305) 372-6339
NOTICE OF ACCEPTANCE (NOA) wNNw.miamidade gov/build!RQcode
DAB Door Company, Inc.
12195 NW 98`h Avenue
Hialeah Gardens, FL 33018
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division
and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas
where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right
to have this product or material tested for quality assurance purposes. If this product or material fails to
perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may
immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA
reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control
Division that this product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code, including the High Velocity Hurricane Zone.
DESCRIPTION: 16'-2"Wide x 161I3igh Steel Sectional Garage Door w/ Window Lite Option
APPROVAL DOCUMENT: Drawing No. 02-21, titled "Sectional Garage Door", dated 09/10/02, with last
revision E dated 01 /06/10, sheets 1 through 5 of 5, prepared by Al-Farooq Corporation, signed and sealed by
Arshad Viqar, P.E., bearing the Miami -Dade County Product Control renewal stamp with the Notice of
Acceptance number and expiration date by the Miami -Dade County Product Control Division.
MISSILE IMPACT RATING: Large and Small Missile Impact Resistant
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been
no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change
in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of
any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to
comply with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA # 09-0128.02 and consists of this page 1 and evidence pages E-1 and E-2, as well as
approval document mentioned above.
The submitted documentation was reviewed by Carlos M. Utrera, P.E.
NOA No. 10-0216.04
Ipy�pECy Expiration Date: July 21, 2015
"JAPPROVEDApproval Date: March 31, 2010
4�013 ( , / /� Page 1
DAB Door Comnanv, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
A. DRAWINGS
1. Drawing No. 02-21, titled "Sectional Garage Door", dated 09/10/02, with last revision
E dated 01/06/10, sheets 1 through 5 of 5, prepared by Al-Farooq Corporation, signed
and sealed by Arshad Viqar, P.E.
B. TESTS
1. Test Report on Large Missile Impact Test and Cyclic Wind Pressure Test, of
"Sectional Residential Door.with Windows", prepared by Hurricane Engineering &
Testing Inc., Report No. HETI 03-1328, dated 07/15/03, signed and sealed by Rafael
E. Droz-Seda, P.E.
2. Test Report on Uniform Static Air Pressure Test, of "Sectional Residential Door"
prepared by Hurricane Engineering & Testing Inc., Report No. HETI 03-1329, dated
07/15/03, signed and sealed by Rafael E. Droz-Seda, P.E.
3. Test Report on Tensile Test per ASTM E-8 of "Sectional Residential Door (skin)",
prepared by Hurricane Engineering & Testing Inc, Report No. HETI 03-T078, dated
10/31/03, signed and sealed by Rafael E. Droz-Seda, P.E.
"Submitted under NOA # 05-0228.02"
4. Test report on Salt Spray (Corrosion) Test per ASTM B 117 of a painted G-40 steel
panels, prepared by Celotex Corporation, Test Report No. 258592, dated 08/17/98,
signed by W. A. Jackson, P.E.
"Submitted under NOA # 03-0210.04"
C. CALCULATIONS
1. Anchor verification calculations prepared by Al-Farooq Corporation, complying with
F.B.0 2007, dated 12/19/08, signed and sealed by Humayoun Farooq, P.E.
"Submitted under NOA # 09-0128.02"
D. QUALITY ASSURANCE
1. Miami Dade Building Code Compliance Office (BCCO)
�/ rd
Carlos M. Utrera, P.E.
Product Control Examiner
NOA No. 10-0216.04
Expiration Date: July 21, 2015
Approval Date: March 31, 2010
E-1
DAB Door Comnany, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
E. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No. 08-0305.02, issued to SABIC Innovative Plastics, for their
Lexan Sheet Products, approved on 04/24/08 and expiring on 07/17/13.
2. Notice of Acceptance No. 07-1016.07, issued to Insulfoam, LLC, for their
Insulfoam Expanded Polystyrene Insulation, approved on 11/29/07 and expiring on
11/29/12.
3. Notice of Acceptance No. 07-1107.08, issued to Dyplast Products, LLC, for their
Expanded Polystyrene Block Type Insulation, approved on 02/28/08 and expiring on
01/11/12.
4. Notice of Acceptance No. 07-0301.10, issued to Dyplast Products, LLC, for their
Dyplast ISO -CI Polyisocyanurate Insulation, approved on 06/07/07 and expiring on
01/11/12.
1. Test Report on Accelerated Weathering Using Xenon Arc Light Apparatus Test per
ASTM G155 of "PVC Extrusion Material', prepared by Hurricane Engineering &
Testing, Inc., Report No. HETI 04-A002, dated 09/27/04, signed and sealed by Rafael
E. Droz-Seda, P.E.
2. Test Reports on Tensile Test per ASTM D638 of "PVC Extrusion Material', prepared
by Hurricane Engineering & Testing Inc., Report No. HETI 04-T251, dated 11 /29/04
signed and sealed by I. Ghia, P.E.
3. Test Report on Self -Ignition Temperature Test, Rate of Burn Test and Smoke Density
Test of "REHAU non -foam PVC extrusion material', prepared by ETC Laboratories,
Report No. 04-761-15019.0, dated 05/06/04, signed and sealed by J. L. Doldan, P.E.
"Submitted under NOA # 05-0228.02"
F. STATEMENTS
1. Change of engineer letter issued by Al-Farooq Corporation, dated 01/08/10, signed
and sealed by Arshad Viqar, P.E.
2. No change to product letter issued by DAB Door Company, Inc, dated 02/09/10,
signed by Roseanne Berger.
1. Statement letter of code conformance issued by Al-Farooq Corporation, dated
12/05/08, signed and sealed by Humayoun Farooq, P.E.
2. Statement letter of no financial interest issued by Al-Farooq Corporation, dated
12/05/08, signed and sealed by Humayoun Farooq, P.E.
"Submitted under NOA # 09-0128.02"
Carlos M. Utrera, P.E.
Product Control Examiner
NOA No.10-0216.04
Expiration Date: July 21, 2015
Approval Date: March 31, 2010
E -2
Property Appraiser - St.Lucie County, FL Page 1 of 1
PROPERTY RECORD CARD
Goldie E Howard Record: 1 of 1
<<Prev Next » Spec.Assmnt Taxes Exemptions Permits Home Print
Property Identification
�V\ICIE C
Site Address: 4707 MAGNOLIA DR
Parcel)D: 3402-605-0035-000-4 G
Sec/Town/Range 02 :36S :40E
y�
Account #: 36797
Map ID. 34/02N
Land Use: SF Res
Zoning: RS-2
City/Cnty: St Lucie County
Ownership and Mailing
Legal Description
Owner: Goldie E Howard
INDIAN RIVER ESTATES-UNIT-04- BLK 34 LOTS 12 AND 13 (MAP
Address: 4707 Magnolia Dr
34/02N)(OR 1227-2116)
Fort Pierce FL 34982-8528
Sales Information
Assessment 2010 Final Total Land and Building
Date Prig Code Deed
Book/Page 2010 Final: 93600 Land Value: 26200 Acres 1.11
6/3/1999 88500 00 WD
1227 / 2116 Assessed. 93600 Building Value 67400
2/12/1998 84000 00 WD
1128 / 0755 Ag.Credit: 0 Finished Area 1470 SgFt
5/4/1990 25000 02 PR
0691 / 0017 Exempt: 75500
Taxable 18100
Taxes: 877.34
BUILDING INFORMATION
01.
Exterior Features
View:
RoofCover.
SA - Asph Shingle
RoofStruct
HP - Hip
ExtType:
HC- - HC-
YearBlt.
1991
Frame:
Grade:
C- - C-
EffYrBlt:
1991
PrimeWall:
BS - CB Stucco
StoryHght:
0010 - 1 Story
No. Units:
1
SecWall:
Interior Features
BedRooms.
3
Electric:
MX - MAXIMUM
PrmintWall:
DW - Drywall
FullBath
2
HeatType.
FHA - FrcdHotAir
AvgHt/FI:
STD
1/2Bath:
0
HeatFuel:
ELEC - Electric
Prm.Flors
CU - Carpet
%A/C:
100
%Heated:
100
%Sprinkled:
0
Special Features and
Yard Items
Land Information
Type
Y/S Oty.
Units Qual. Cond.
YrBlt. No. Land Use
Type
Measure
3CNT - 3CNT
S 1
1 AV AV
1991 1 0100-SF Res
220 -Front Ft
220
SDSF - SITE DEV S-F Y 1 1 AV AV 2001
THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED
Depth
220
http://www.paslc.org/prc.asp?prclld=340260500350004 6/9/2011
7-1/2" X 3" X .071"
0 GALV. STEEL END ROLLER HINGE
W/ (6) #14 X 5/8" SMS
0 7-1/2" X 2-1/4" X 18 GA.
GALV. STEEL CENTER HINGE
W/ (4) #14 X 5/8" SMS
LOCK
F 2/ DOOR
1' W X .15 THK. LATCH
PUSH NUT TOP FIXTURE 5-1/2' X 2-3/4' X 0.1" iLe
STEEL PLATE WITH ONE 5/16-18 MS W/ NUT OPTIONAL DOOR VIEWER 0
FASTENED TO END STILE WITH TO BE INSTALLED AT �+
\ (6) #14 X 3/4" SELF DRILLING SCREWS ANY CENTER STILE 7
o
00
1
O O CENTER STILES
n SEE SCH. 'A'
SPRING LOADED SLIDE BOLT LOCK (BOTH SIDES)
FASTENED W/ (4) #14 X 1/2" S.M.S.
5/8" MIN. LOCK ENGAGEMENT CONFORMS TO
FBC 1012 REGARDING GARAGE DOORS
.158 DIA. GALV. AIRCRAFT TYPE O
W% MINE 5 TOCI PRESS SAFETY FACTOR
2-3/4"W X 5-5/8"H X .090" THK.
STEEL PLATE, 1-3/8" DEEP 1
WITH (3) J14 X 3/4" ��
SELF DRILLING SCREWS
BRACKET
STD. LIFT DOOR
DOOR
HEIGHT
CONSISTS OF
TOTAL III OF
'U' BARS AT
EACH DOOR
6'-6'
2 SECTIONS 18"
2 SECTIONS 21"
3
6'-9"
1 SECTION 18"
3 SECTIONS 21'
7'
4 SECTIONS 21'
-
7'-3" 1
-
-
7'-6"
5 SECTIONS 18'
-
7'-9"
4 SECTIONS 18"
1 SECTION 21"
8'
3 SECTIONS 18'
2 SECTIONS 21"
8'-3'
2 SECTIONS 18'
3 SECTIONS 21"
4
8'-6"
1 SECTION 18'
4 SECTIONS 21'
8'-9"
5 SECTIONS 21"
-
9'
6 SECTIONS 18"
-
9'-3"
5 SECTIONS 15"
1 SECTION 21"
9'-6'
4 SECTIONS 18"
2 SECTIONS 21'
9'-9"
3 SECTIONS 18"
3 SECTIONS 21'
10'
2 SECTIONS 18"
4 SECTIONS 21'
10'-3"
1 SECTION IS'
5 SECTIONS 21"
10'-6'
10'-9"
6 SECTIONS 21'
6 SECTIONS 18'
-
1 SECTION 21'
5
11'
11'-3"
11'-6"
i V-9"
5 SECTIONS 18'
4 SECTIONS 18'
3 SECTKNNS 18'
2 SECTIONS 18'
2 SECTIONS 21'
3 SECTIONS 21"
4 SECTIONS 21"
5 SECTIONS 21"
12'
T SECTIONS 18"
6 SECTIONS 21"
12'-3"
12'-6"
17 SECTIONS 21"
6 SECTIONS 18"
-
2 SECTIONS 21'
SECTIONS IW
3 SECTIONS 21"
13'
• SECTIONS IV
4 SECTIONS 21"
13'-3"
3 SECTIONS 18'
5 SECTIONS 21"
13'-6"
2 SECTIONS 18'
6 SECTIONS 21'
6
13'-9'
1 SECTION 18'
7 SECTIONS 21'
14'
8 SECTIONS 21'
-
14'-3"
6 SECTIONS 18'
3 SECTIONS 21'
14'-G"
5 SECTIONS 18"
4 SECTIONS 21"
14'-9"
4 SECTIONS 18"
"5 SECTIONS 21"
15'
3 SECTIONS 18"
6 SECTIONS 21"
'7
T SECTIONS IV
SECTIONS 21'
15'-6'
1 SECTION 18'
8 SECTIONS 21'
9 SECTK>rIS 21"
-
16'
16 SECTIONS 18"
,4 SECTION5 21"
BRACKET
LOW HEADROOM
DOOR OPTION
r- — A
i 11OVA NJ r_�j OVA
� tl
IAICI I®i
A A
� 1-1 � IV,
1 mil
11=1�1�1=1 A Ima !A
PA
Iy Y Y Y Y Y YI
7-7/8" X 3-1/8" X .010"
STEEL PLATE l OPTIONAL VENTS
WITH (4) #14 X 3/4" SDS (3) 5" WIDE AT 7" O.C. MAX.
OPNG. AREA NOT TO EXCEED 120 SO. IN
ENTER STILE
01
H
END STILE
LOCK BAR GUIDES
INSTALLED ON END STILE
WITH (4) 114 X 5/8" SMS
18T X 6W LOCK BAR
MAX.
WIDTH
OPTIONAL FLUSH FACE L A
WOOD GRAIN DESIGN
16'-2"
INSIDE ELEVATION DAB DOOR MODEL 824
MAX. SIZE 16'-2" WIDE X 16'-0" HIGH
RAISED PANEL EMBOSSED DOOR 24 GA. ROLL FORMED STEEL
DESIGN PRESSURE RATING = + 36.0 PSF
- 44.0 PSF
THIS PRODUCT IS RATED FOR LARGE MISSILE IMPACT
ENGAGES IN TRACK GENERAL NOTES
ON EACH SIDE OF DOOR
CENTER STILES SCHEDULE 'A' 1. THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE
OUTSIDE KEYED LOCK
LOCK BAR LOCKING SHOWN
ALT. TO LOCKS SHOWN ABOVE ® ®® ®
8'-0" TO 9'-10" _I
DOOR w1nTWc
CENTER STILES
CONFIGURATION
REQUIREMENTS OF THE FLORIDA BUILDING CODE 2007 EDITION INCLUDING
HIGH VELOCITY HURRICANE ZONE.
2. ANCHORS SHALL BE AS LISTED, SPACED AS SHOWN ON DETAILS.
ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL
DRESSING OR STUCCO.
3. ALL BOLTS, NUTS AND WASHERS SHALL BE ZINC PLATED CARBON STEEL.
4. ANCHORING OR LOADING CONDITIONS OTHER THAN THOSE SHOWN IN
tu,o w000rn•e,
DOOR WIDTHS
/ OF CENTER STILES
9i',100"
10'-0" TO
2
1"
TO 1'-0"
3
12'-0"
TO 13''--100
4
15'-11" TO 16'-2"
5
5. A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY.
® ® ®® ® ®® ® Engr; ARSHAD VIOAR
CML � = WW
FIA, PE f 38663 amplyftvft*0"Oft
10'-0" TO 11'-10" 14'-0" TO 15'-10" C.A.N. 3538 ��iCb� t,
IP DOOR WIDTHS I DOOR WIDTHS AeoepluteNlo / �T
/s
AT (4) SECTIONS DOORS ® ® ®® ® ® ®® ® ® � +CPi�tCoMW
TOP SECTION WITH 'U' BAR Ap�
ALL OTHER DOORS 12'-0" TO 13'-10" I I 15'-11" TO 16'-2"
' JHlV �t 2010
TOP SECTION WITHOUT 'U' BAR DOOR WIDTHS DOOR WIDTHS �!
Un <
Z 2 2 V
S m W
U O U C
U U 8
m 2o
mit
3 a
W
po > o 0
¢ O K 7 W
drowing no.
02-21
sheet 1
0
z
O -
V O
Z
N U
�Z
O Ld in
X 2-1/4" X 3/4" X 2"
vnLv. STEEL U.BAR REINFORCING TRUSS
0 BOTTOM OF PANEL TRUSS FASTENED TO
VERTICAL INTERMEDIATE STILES W/ TWO
114 X 5/8" S.M.S. AND TO END STILE
W/ FOUR #14 X 3/4" SELF DRILLING S.
1/2" X 1-3/4" X 16 GA.
OPEN TUBE
0 TOP & BOTTOM
OF EACH PANEL
BOTTOM SEAL
.058 ALUM PLATE
WITH 1/8" X 1" S.M.S. 0 48" O.C.
AND RUBBER WEATHERSTRIPPING
1 ST SECTION (BOTTOM)
OPTIONAL STOP
BY DOOR
STEEL TRACK BRACKET FASTENED
TO WOOD JAMB WITH
5/16" X 1-5/8" LAG SCREW —
(FULLY THREADED) /
HEX WASHER HEAD TYPE A
ONE PER BRACKET
SOUTHERN PINE •a•
0.55 S. /,
•�
1- MIN
DIST.
I
1-3/16"
1.9" X 2.19" X 3.3" X .090"
STEEL TRACK BRACKETS
SEE SHEET 3 FOR SPACING
2-1/8- X 1 " X .078"
GALV. STEEL TRACK
FASTENED TO TRACK PLATES
W/ 1/4-20 X 5/8" TRUSS HD.
SLOTTED M.S. & LOCK NUT
I
NFORCING V BARS AS REDD.
: CHART ON SHEET 1
16 GA. X 2-1/4" X 3/4" X 2"
GALV. STEEL U.BAR REINFORCING TRUSS
TRIISS FASTENED TO VERTICAL INTERMEDIATE STILES
TWO 1 14 X 5/8" S.M.S. AND TO END STILE
FOUR 111 14 X 3/4" SELF DRILLING SCR.
INTERMEDIATE SECTION
WITH OR W/O REINFORCING
1 14 X 5/8' SMS
6 PER HINGE
1/2" X 1-3/4" X .058" FORMED STEEL
GLUED TO PANEL AND SECURED TO
END STILE WITH (4) 3/16" POP RIVETS
1-7/8' X 2-5/8" X .049" STEEL
CENTER STILE, GLUED AND RIVETED
TO PANEL W/ (4) 3/I6" RIVETS
If 14 X 5/8" S.M.S.
r 4/ HINGE
tl I II
7/8" PUSHNUT
INSTALLED ON ROLLER SHAFT
t
IF
7-1/2" X .050"
GALV. STEEL_
CENTER HINGE
INTERIOR SIDE
SECTION B-B
TOP SECTION
USE REINFORCING V BAR AT
TOP SECTION ONLY AT
FOUR SECTION DOORS
24 GA. STEEL PANEL
FLAPS BENT OVER PANEL
1 °
1/2" PUNCHED HOLES J I
0 4" O.C. ('
0. I
I
I
k'1
i
I
I
k'1
;A. X 2-1/4" X 3/4" X 2"
. STEEL U.BAR REINFORCING TRUSS
iS FASTENED TO VERTICAL INTERMEDIATE STILES
TWO If 14 X 5/8' S.M.S. AND TO END STILE I
FOUR jt 14 X 3/4" SELF DRILLING SCR. K)
3/4" X 2" X 2-1/2" X .049" STEEL
END STILE, CONNECT TO PANELS WITH
FLAPS AND (5) OR (6) 3/16" ALUM RIVETS
SEE DETAIL ABOVE
EDGE
DISTANCE
3/16"
POP RIVETS ° 11-3/1
� c
7-1/2* X .071 "-j U \
END ROLLER HINGE
PLASTIC/STEEL ROLLERS
1.82" DUI. X .50"
W/ .44 DIA. X 4-1/4" STEM
I A
3/16" POP RIVETS I
AT 4" O.C.
(6) FOR 21 " STILES °
(5) FOR 18" STILES
i
°
END STILE
SOLID BRASS DOOR VIEWER
BY 'SCHLAGE SECURITY HARDWARE'
INSTALLED IN 9/16" DIA. HOLES IN CENTER STILE
POSITIONED AT EYE LEVEL
ANCHORS:
x/8" niA. POWER -BOLT 13Y 'POWERS'
A) 2" MIN. EMBED INTO CONCRETE (3000 PSI MIN.)
2" MIN. EDGE DISTANCE
A/8" DLL HLC sLEEVE BY 'HILTV
B) 1-1/4" MIN. EMBED INTO CONCRETE OR FILLED BLOCK
2-1/4" MIN. EDGE DISTANCE INTO CONCRETE
4" MIN. EDGE DISTANCE INTO FILLED BLOCK
CONCRETE Vc = 3000 PSI MIN.
C-90 GROUT FILLED BLOCK I'm - 2000 PSI MIN.
ANCHOR TYPE A OR 8
(1) PER BRACKET
SEE SHEET 3 FOR BRACKET
CIVIL
FLA. PE / 38863
C.A.N. 3538
1/4-20 SS BOLT
do NUT cv4l
JAN 0 S 2010
V Q
N
I
N
O
0 /
W
Q g C4 "
0w xx
IL
0 LL
0 a
C �
oaQQ�
0�;��
�O
w IL
W N: O
J 0MQ
Q Wei t-
Of c0
O O
O
0 M
W
O Qu-
Q U H vi N
O ? 00 w iO
N a) a I
Z Q N
O 3 ,n
w Z3Q: o
N c,
2
0
pitoLxjcT
REWWRID
I
us ooal�iyiH{ riib 1* Fk"
swidbo
Cam $
Atoepil.ec No y °
O Y
dro wing no.
Minim
02-21
sheet Z of 5
POP RIVETS
GALV. STEEL
TOP ROLLER BRACKET
FASTENED W/ (6) it 14 X 5/8 S.M.S.
14 GA. GALV. STEEL ADJUSTABLE
SLIDE FASTENED TO BRACKET
W/ 5/16-18 X 3/4` HEX HEAD
M. SCREWS do NUTS.
1-5/8" LAG SCREWS INTO WOOD OR
5/16" SLEEVE ANCHORS
WITH 1-1/4" EMBED INTO MASONRY
3 PER BRACKET
/2" X 4-1/4" X 13 GA. STEEL PLATES
TO 1-1/2" X 1-1/2' X 14 GA. ANGLE --
FASTENED TO TRACK - - WITH (4) 1/4-20 SS. BOLT do NUTS - --
HORIZONTAL REINFORCEMENT \
1/2" X 1-3/4" X .058" FORMED STEEL
GLUED TO PANEL AND FASTENED TO
VERTICAL STILES WITH 2" X 5-1/2" X .104"
(2) 3/16" POP RIVETS GALV. STEEL
FASTENED W/ (4) # 14 X 5/8" S.M.S.
TOP ROLLER BRACKET FOR
LOW HEADROOM DOOR OPTION
HORIZONTAL REINFORCEMENT
1/2" X 1-3/4' X .058' FORMED STEEL
GLUED TO PANEL AND FASTENED TO
VERTICAL STILES WITH
(2) 3/16" POP RIVETS
5/16" MEETING RIB
PLASTIC/STEEL ROLLERS
1.82" DIA. X .50"
W/ .44 DIA. X 4-1/4- STEM
OPTIONAL INSULATIONS:
BY 'DYPLAST PRODUCT
EPS-EXPANDED POLYSTYRENE
DENSITY = 1.05 PCF
N.O.A. #07-1107.08
OR
ISO-25 POLY-ISOCYANURATE
DENSITY = 2.0 PCF
N.O.A. #07-0301.10
OR
BY 'INSULFOAM LLC'
DENSITY = 0.92 PCF
N.O.A. #07-1016.07
14 GA. GALV. STEEL
ROLLER HINGES FASTENED
W/ (6) / 14 X 5/8" SMS
MIN. .024" ROLL FORMED STEEL PANEL
DRAWING QUALITY G-40
MIN. YIELD STRENGTH - 39 KSI
WITH PRIMER AND BAKED -ON
POLYSTER PAINTED TOP COAT
APPLIED TO BOTH SIDES OF STEEL
12 GA. GALV. STEEL
/FASTENED
W/ (4) / RBOTTOM BA4 KXTS/8` SMS
BOTTOM SEAL
.058 ALUM PLATE
WITH 1/8" X 1' S.M.S. 0 48" O.C.
SECTION A —A AND RURRER WEATHERSTRIPPING
SEE SHEET 2 FOR LOCATION
OF REINFORCING TRUSSES
x
cv _
4J U'
= w
x
z CC
wo
oa
HORIZ. TRACK SUPPORT,
CENTER SUPPORT REOD. ON DOORS
EXgEEDINC 8 FT. IN HEIGHT
II II A — I
II
A—J
HORIZ. TRACK LENGTH = OPENING HEIGHT PLUS 12'
14 GA, CALV. STEEL TRACK
2 X 2 X 1/8" HORIZ. ANGLE
SPOT WELDED TO HORIZ. TRACK
WITH TWO WELDS AT 1-1/2" APART
FIRST AT 3" O.C.
REST AT 9" O.C.
CONNECTED TO FLAG BRACKET ANGLE
W/ 3/8-16 X 3/4" BOLT & NUT
AND TO SPRING SHAFT GUIDE WITH
(2) 1/4-20 X 5/8" BOLT do NUT
VERTICAL TRACK
2-1/8' X 1" X .080"
SECTION A -A
DOOR
• SECTION HEIGHTS
BRACKET PLACEMENTS
2ND
3RD
4TH
5TH
81
82
B3
B4
B5
B6
B7
B8
6' 0"
18"
18"
18"
N/A
1"
11-3/4"
23"
34"
45"
56"
67"
-
57'-0"21"
18"
18"
21"
N/A
1"
11-3/4"
23"
34"
45"
56"
67"
-
21"
21"
21"
N/A
1"
11-3/4'
23"_
34"
45"
56"
67"
-
18"
18"
18"
18"
1"
11-3/4"
23"
34"
45"
56"
67"
78-1/4"
18"
18"
18"
21"
1"
11-3/4"
23"
34"
45"
56"
67"
78-1/4"
•-SECTIONS AKE NUMdLKtU WAKIIN{o Al IMG bVI1VM
FOR DOORS MORE THAN 8 FT. HIGH, USE ADDITIONAL TRACK BRACKETS AT 10" O.C.
Do
i Ll I II 1.9" X 2.19' X 3.3" X .090"
STEEL TRACK BRACKETS
7_j
n 2-3/16" HIGH
m CONNECTED TO TRACK WITH
1/4" BOLTS & NUTS.
Cal I
d
ID
ID
TRACK CONFIGURATION
VERTICAL LIFT HIGH LIFT STANDARD LIFT
AVAILABLE TRACK OPTIONS
CIVIL
FLA. PE j 38863
C.A.N. 3538
JAN 0 8', 2010
LOW HEADROOM
DOUBLE TRACK
iy7i71r..
V.V o
to
N
mI�li
O O
O M
O M
Lil
LLI
� Q�
Q
Z
CO W
N d7 0 1
z Q
O O
V O ZS n
N tow h
J
eN- Q J
drawing no.
02-21
sheet 3 of 5
- 401V
5/ 16" X 1-5/8-
WOOD FRAME BUILDIN
STUD WALLS OR DOOR OPENING (NOT BY DAB DOORS)
SHALL BE FRAMED SOLID BY NOT LESS THAN
(3) 2X6 PRESSURE TREATED GRADE 2 SYP OR BETTER
WOOD STUDS.
STUD WALLS TO BE CONT. FROM FOOTING TO TIE BEAM,
ENGINEER OF RECORD TO VERIFY ADEOUACY OF THE
SUPPORTING STRUCTURE.
WOOD BUCK CONNECTION TO MASONRY
TRACK SHALL BE SECURED WITH CONT. STEEL ANGLE TO PRESSURE
TREATED 2X6 SYP WOOD JAMBS WHICH SHALL BE ANCHORED TO
GROUTED REINFORCED MASONRY BLOCK WALL OR CONC. COLUMN WITH
1 /4" ULTRACON BY 'ELCO' WITH SPACING OF
16" O.C. INTO BLOCK WALL, WITH 2-1 /4" MIN. EMBED
13" O.C. INTO 3000 PSI CONCRETE, WITH 1-3/4" MIN. EMBED
2-1/2` MIN, EDGE DISTANCE
1 /4" TAPPER BY 'POWERS' WITH SPACING OF
11" O.C. INTO BLOCK WALL, WITH 1-1/2" MIN. EMBED
13" O.C. INTO 3000 PSI CONCRETE, WITH 1-3/4" MIN. EMBED
3" MIN. EDGE DISTANCE
3/8" CONFLEX BY 'ELCO' OR
3/8" LDT BY 'ITW' WITH SPACING OF
23" O.C. INTO 3000 PSI CONCRETE, WITH 2-1/2" MIN. EMBED
3" MIN. EDGE DISTANCE
3/8" HLC SLEEVE BY 'HILTI' WITH SPACING OF
13" O.C. INTO BLOCK WALL, WITH 1-1 /4" MIN. EMBED, 4" MIN. EDGE DIST.
15" O.C. INTO 3000 PSI CONCRETE, WITH 1-1/4- MIN. EMBED AND
2-1/2" MIN. EDGE DISTANCE
THE BLOCK WALL CELLS SHALL BE GROUT FILLED AND REINFORCED
WITH FOUR If 5 BARS EXTENDING INTO FOOTING AND INTO TIE BEAMS
ALL BARS SHALL BE CONTINUOUS FROM TIE BEAMS TO FOOTING.
PREPARATION OF JAMBS BY OTHERS
STEEL STRUCTURE BY OTHERS
MUST SUPPORT THE LOADS IMPOSED
BY DOOR SYSTEM
5/16" DIA. BOLTS
WITH WASHER do NUT
AT 12" O.C. MAX.
0
�i 1-1//4" X 2-1/2" X 14 GA
1-1/2" I CONT. STEEL ANGLE
12 GA. GALV. STEEL
FLAT BRACKETS t3" LONG
AT 12" O.C. IN DOOR OPNG.
AT 18" O.C. ABOVE DOOR OPNG.
CONNECTED TO CONT. ANGLE
W/ (3) SPOT WELDS AT EACH SIDE
ANCHOR SPACING
ANCHORS
STRUCTURE
EMBED
SPACING
EDGE DIST.
3/8" HLC SLEEVE BY 'HILTI'
CONC.
1-1/4`
8"
2"
3 8" HLC SLEEVE BY 'HILTI'
FILLED BLOCK
1-1 4"
8"
4"
3 8" DYNABOLT BY 'ITW'
CONC.
1-1/2
8"
2-1/2"
3 8" DYNABOLT BY 'ITW'
FILLED BLOCK
1-1/2
8"
3-3/4"
3/8" POWER -BOLT BY 'POWERS'
CONC.
2"
8"
2"
3/8 SLEEVE -ALL 8Y SIMPSONS'
CONC.
1-1/2
8"
3"
EDGE DIST.
CONCRETE Cc = 3000 PSI MIN.
C-90 GROUT FILLED BLOCK f'm = 2000 PSI MIN
2-1/8- X 1" X 14 GA.
GALV. STEEL TRACK
FASTENED TO TRACK PLATES
W/ (2) 1/4-2OX5/8" TRUSS HD.
SLOTTED M.S. do LOCK NUT
ALTERNATE TRACK INSTALLATION
n9r: A"HAU ViWAN
CIVIL
F1A PE / 38863
CAN. 3538
_IAN 0 „ WO
Z
0 Z Q
Q � N
O W
Q
O
ivy � lq p
Va')M 8
0 (L 'A
0 y
O
Q W U. Ip
IL Z 1A o
M
Q W � H
cr_ 00
O
0 M
W
O � �
Q
U =
Z F- vi CN
00 w tO
J (n 0) p I
0:
g 0 30 2
U LLJfcl Z 2 v�
Ul mm � LLJ
a cv a J
a •- _ L�'_j
VI N
U
0,u8e
2
O Z O N U
U ~ U
m W m U
U 4
0. a W z
r
U I �
x Z IY a w
� ylp c o 0
oC p o n o
_
lc�
0
PRODUE7 RENEVIM o 0
m oowwish fm FUrift I
s
S r O Y
v w VBy
y
R>— drawing no.
nA 02-21
sheet 4 of 5
DOOR PANEL
24 GA, (.024) STEEL MIN,
7/16` DIA. WASHER
#8 X 3/4" SMS
1 I O 3/8` FROM ENDS
O111111
AND 7" O.C. MAX.
(4) #8 X 3/4" SMS
O1-3/8" FROM ENDS
AND 6-1/2" O.C. MAX.
.175 X .062 DEEP
IIII GROOVE
I I
IIII
IIII
IIII
IIII 1/4" POLYCARBONATE LEXAN
I BY SABIC INNOVATIVE PLASTICS
IIII NOA 008-0305.02.
tIr
W
d 0
III
I111
=
O Fx
W
Z
W
IIII
IIII
IIII
IIII
IIII
I I
IIII
IIII
IIII
IIII
I I
IIII .175 X .062 DEEP
IIII GROOVE
�\I
11 III I
I III I (4) %8 X 3/4" SMS
0 1-3/8" FROM ENDS
I III I AND 6-1/2" O.C. MAX.
I
O
1
� III I 1
I
#8 X 3/4` SMS
O 3/8` FROM ENDS
AND 7" O.C. MAX.
7/16" DIA. WASHER
DOOR PANEL
24 GA. (.024) STEEL MIN.
* PLASTIC COMPLIES WITH
SECTION 2612 OF FBC 2007
SEE EVIDENCE PAGE
.500
�.250
d
N
Z n
I
0
�
W
�
GF
Z n
w
1.765
1.725
1800
Q d n
Ow
1.144
a
o�
8
Q m
.176
Q Q
* EXTERIOR FRAME
* INTERIOR FRAME
m
RIGID PVC ONE PIECE INJECTION
RIGID PVC ONE PIECE INJECTION
a W 3 LL
�_"
QWr1►0
INSIDE ELEVATION
RAISED PANEL EMBOSSED DOOR WITH OPTIONAL WINDOWS
/8 X 3/4" SMS C
O 3/8" FROM ENDS .175 X .062 DEEP
AND 4-1/2- O.C. MAX. GROOVE
i !
Engr. ARSHAD VIW
�� -_ - --- --- - -- CML
- - - - - FLA, PE / 38863
- - - - - _ C.A.N. 3538
DOOR PANEL
24 GA. (.024) STEEL MIN. EXTERIOR
15/16` MIN, D.L. OPG.
GLAZING BITE
WINDOW WIDTH JAN 0 I� ?010
0
PRODUCT RENEWED o 0
u 00mvilybe YV0 do Fk h
NNo 10 _ a
1w1t n ho�uctcomw drawing no.
a 11 02-21
sheet 5 of 5