HomeMy WebLinkAboutSUBMITTED PAPERSDate: t t9 Fee Due: —
Permit #
IZ16 (0 —U?�qh
Planning & Development Services
Building & Code Regulations Division
2300 Virginia Ave.
Fort Pierce, FL 34982
(772)462-1553
SPECIALTY PERMIT APPLICATION
e -� 3P
�dl
❑ Electrical Ll Plumbing ❑ HVAC ❑ Fence SCAT yv"
❑ Shed El Demolition ❑ Gas ❑ Siding St. 4 1 Co
Seepage 2 for instructions and additional paperwork required for specialty permits count
1. Location/Site Address: 4901 SAN DIEGO AVE
2. Parcel ID Number: 1431-703-0098-000-8
Office (Ise
Only
Section
Township
Range
Map Page
Zoning
Land Use
Initials
r�
1111
31 -5
C ,/
J '1
-
3. Complete Description of Project or Work: INSTALLATION OF SOLAR WATER HEATER
4. Owners Information
Name: ALPHONSO ROWE
Address: 4901 SAN DIEGO AVE
City:
5. Contractors Information
FL Reg/Cert #:
County Cert#:
UCWA
FT PIERCE State: FL Business Name: TRADEWIND SOLAR
Zip: 34950
Phone: 7723427094 Phone: 7724644630 Fax:
6. Value of Construction: $ 2000.00
7723986131
OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in
compliance with all applicable laws regulating and zopinV
PRINT OWNER OR CONTRACTOR NAME 1 , SIG TURE OF OWNER OR CONTRACTOR
STATE OF FLORIDA, COUNTY OF
ACKNOWLEDGED BEFORE ME THIS ✓1 DAY OF 20 11 BYy
WHO IS PERSONALLY KNOWN TO ME OR WHO HAS PRO UCED
AS NTIFICATIO
JEAN M. KELLY
SIGNAT OF NOTARY TYPE OR PRINT NAME OF OT Y y, MY Ctj�etl{�kSSION # DD684633
,�:
+,�oP E:XFIRES June 12, 2011
COMMI ON NUMBER i407) FioridallotarySarvice.com
NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR
LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
EXEMPT: A/C -HEAT REPLACEMENT WITH CONTRACT UNDER $7500.00
Revised 04/26/2010
FLORIDA SOLAR ENERGY CENTER'
Approved Solar Energy System
Approval Date: Jun 2011
FSEC # S00171E
DISTRIBUTOR SYSTEM
Solene Solene/Aurora 80PV
950 Sunshine Lane
Altamonte Springs, Florida 32714
This system was evaluated by the Florida Solar Energy Center (FSEC) in accordance with the Florida
Standards Program for Solar Domestic Water and Pool Heating Systems (FSEC Standard 104-05) and was
found to meet the minimum standards established by FSEC.
North Central South
The calculated Florida Energy Factors far this system are: 12.(1 15A 15.4
DESCRIPTION
Collector Manufacturer
Model Number
Units Total Rating (Btu)
1, Solene
Solene/Aurora SLAR40
2 75,800
2.
3.
4.
Tank Manufacturer
Model Number
Capacity (gal) Type: Direct
1. Lochinvar
FTA-120K
120
2. Rheetn
81 RV 120-1
120
3. AO Smith
Sun 120
120
4. Any Equivalent UL Listed Tank
120
Manufacturer
Model Number
Power Draw (Watts) Rated Power
_Pump
1. El Sid
SID10PV
5 11100 H.P.
2. March
809BR-24VDC
15 1/100 H.P.
3. Laing
D5 09 OB
10 1/100 H.P.
4.
Controller Manufacturer
Model Number
Type: Photovoltaic
1. Sunflre
AE-10ST
2. Kyocera
KS-10
3. Power Up BSP-10-12
Freeze Protection
i . Freeze prevention valve
2. Manual drain down
Other Major Components
FILE COPY
1679 CI.F.NgtARr YkAAP, tanvti F1t)mp..\ 32912-5703 - Tei.121-638-1000 - Fns 321-638-1010 mn�r.fsrc uc4aiu
U,vnhrsnv SvsWA a FLORM - Av Eowt O?PORYUPMAO FvejAgm Aenov EknoVER • A REsEAwH tvmnnr of nff Lk&v iy or CEmPAL Hoag"
FSEC # S00171 A
FLORIDA SOLAR ENERGY CENTER''
Approved Solar Energy System
Approval Date: Jun 2011
BUI DING D,�,..viv
VVIEED
Is^w REVMWE:L _
DATE /4
PLA S ANb PERId1F
MUST BE KEPT ON JCB C:R
"",MOCTION WILL
1106 aiS1 R
1079 CLeatet.:uE Rt1,uP. (-'kx-.),t. FuIRR*% 32922.5703 • TE .121-638.1000 - Fv 321-638-I OIL) • awwAcc.t1cl:edu
UNAaRSAY SYSFET.1 OF FLoRow • A4 E:(X 1 0,-' FU\"/AFRIRh'ATW ACTON EFIPEOWR • A RIESEA:CH INSTITUTE OF THE U\' FKC1Y OF CENIPAL FLmC1.
Property Appraiser - St.Lucie Ce—ly, FL
Page 1 of 1
PROPERTY RECORD CARD
Alphonso E Rowe Record: 1 of 1 <<Prev
Next >> Spec.Assmnt
Taxes Exemptions Permits Home Print
Property Identification
,��CIE CO
Site Address: 4901 SAN DIEGO AV
ParcellD: 1431-703-0098-000-8 Gy
Sec/Town/Range 31 :34S :40E
Account # 10681
yO
Map ID. 14/31S
Land Use: SF Res
Zoning: RS-4
City/Cnty: St Lucie County
Ownership and Mailing
Legal Description
Owner. Alphonso E Rowe
HARMONY HEIGHTS ADDN NO 3 BILK E LOTS 12 AND 13 (OR 1272-
Address 4901 San Diego
2038)
Fort Pierce FL 34946-1005
Sales Information
Assessment 2010 Final
Total Land and Building
Date Price Code Deed
Book/Page 2010 Final 27200
Land Value: 9700 Acres 0.24
12/28/1999 17000 01 WD
1272 / 2038 Assessed: 24393
Building Value 17500
4/1/1978 19500 00 CV
0285 / 1099 Ag.Credit: 0
Finished Area 702 SgFt
8/1/1977 12500 00 CV
0272 / 0759 Exempt: 24393
Taxable: 0
Taxes: 0
BUILDING INFORMATION
e.=24
Exterior Features
View:
RoofCover
SA - Asph Shingle
RoofStruct
GA - Gable
ExtType
HD -HD
YearBlt:
1953
Frame:
Grade
D - D
EffYrBlt:
1976
PrimeWall:
BP - Conc Block
StoryHght:
0010 - 1 Story
No.Units:
1
SecWall:
Interior Features
BedRooms:
2
Electric:
AV -AVERAGE
PrmintWall
PN - PN
FullBath
1
HeatType:
AvgHt/FI
STD
1/213ath:
0
HeatFuel:
-
Prm.Flors:
CA - A TL/CON
%A/C:
0
%Heated:
0
%Sprinkled:
0
Special Features and Yard Items
Land Information
Type
Y/S Qty
Units Qual. Cond.
YrBlt. No. Land Use
Type
Measure Depth
SDSF - SITE DEV S-F
Y 1
1 AV AV
2001 1 0100-SF Res
210 -Front Ft
102 104
THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED
http://www.paslc.org/prc.asp?prcild=143170300980008 6/10/2011
sz
W U - SOLENE MOUNTING n
COLLECTORS SHALL
BRACKET W/ LAG BOLT SOLENE BRAND
3 J NOT BE INSTALLED IN "CORNER 3"X3"XJ6 THK 3" L 6063T6
AS SHOWN BELOW COLLECTOR
O Q 2'
ZONES" AS SHOWN ON DIAGRAM ALUM SQRTB WITH 1 "DOe
= THK 2Y'4 L ALUM TUBE
a INSERT BOTH ANODIZED, -`� 1 Cr
SOLENE MOUNTING BRACKET I �' C
v W/ LAG BOLT AS
SHOWN BELOW SOLENE BRAND f�
3 z o y�'0 COLLECTORS rcl
QO n
U Z z N M
o W RIDGE _ - z 4 L
SOLENE BRAND S W �� M o
o= ��Q s MOUNT STAND OFF ASSY W W TLL
L-3 SCALE: NTS > i w 'o
z HIP ROOF END woo J
Q CONDITION p-1
IL
w
a SOLENE BRAND ROOF ZONE 3 LONG DIMENSION a` a°
?, COLLECTOR CORNERS GABEL END ROOF SOLENE SO NE BRAND
O MOUNTING LOLL
o HIP ROOF GENERAL CONDI110N BRACKETTOR
CONDITION ROOF CONER ZONE SHALL BE 10 PERCENT
z 0 , PLAN O F COLLECTORS OF SHORT DIMENSION OF BUILDING, OR 40
PERCENT OF MEAN ROOF HEIGHT, OR 7 FT
— WHICH EVER IS SMALLER.
U L-3 SCALE: 3/16"=1'-0" F ..
W 2 ROOF LAYOUT PLAN SHEATHING
FIL
O > GENERALNO L-3 SCALE: NONE /
Of z 1. COLLECTOR CONNECTIONS SHOWN HAVE BEEN DESIGNED TO RESIST WIND LOADS OUTLINED IN THE 2007 FLORIDA BUILDING CODE, AND 2009 O 6 ` Q 51 A
SUPPLEMENT, CHAPTER 16 FOR 146 MPH EXPOSURE "C" WIND VELOCITY AND PER ASCE 7-05, CHAPTER 6.0 FOR 146 MPH EXPOSURE "C" WIND
N VELOCITY TYPICALLY.
2x PT OR UNISTRUT CONTINUOUS ALONG
o 0 2. LAG BOLT CAPACITIES AND EMBEDMENTS ARE BASED UPON "NATIONAL DESIGN SPECIFICATION FOR STRESS GRADE LUMBER AND FASTENINGS" AS PANEL FOR MOUNTING
w LL PUBLISHED BY THE NATIONAL FOREST PRODUCTS ASSOCIATION. APPLY ROOF GRADE SEALANT TO ALL CONTACT SURFACES. W/ 3/8" ST STL ALL-THRD ROD W/ NUT WOOD TRUSS
m } & WASHER EA END - PROVIDE "LOCTTTE" SYSTEM #2 SYP
O z 3. ALL CONNECTIONS ARE FOR ROOFS 0' TO 45' MAX SLOPE CONDITIONS. ALL CONNECTORS ARE FOR MEAN ROOF HEIGHTS NOT TO EXCEED 30'-0". AT ALL NUTS. CENTER RODS ® 3'-0" o/c OR BETTER
MAX SPACING
Q z 4. WIND TUNNEL TEST DATA FOR THESE CONNECTIONS AND ASSEMBLIES HAS BEEN COMPILED BY TEXAS A&M UNIVERSITY, COLLEGE STATION, TX. AND IS
N O AVAILABLE THROUGH HELIOCOL, INC. WIND LOAD CALCULATIONS ARE AVAILABLE THROUGH HELIOCOL, INC. REPORT #SL-,5. MISSED TRUSS SOLENE
w
W E3 5. ALTERNATIVELY SOLENE MOUNTING BRACKET CAN BE FASTENED TO THE SOLENE COLLECTOR WITH EITHER (1) STSTL BOLT AND NUT, OR (2) Y4" , BRAND SPANNER INSTALL
z z SELF TAPPING SHEET METAL SCREWS.
Ow
Z > L-3 SCALE: NTS
c5 N SOLENE MOUNTING a4
Lu SOLENE SOLENE BRACKET AND STAND SOLENE MOUNTING L�
o 0 MOUNTING MOUNTING OFF ASSY
WOOD TRUSS BRACKET AND STAND
z z BRACKET ROOF BRACKET FLAT SOLENE BRAND SYSTEM #2 SYP OFF ASSY SOLENE BRAND
Q 3 ROOF SOLENE BRAND SHEATHING CONCRETE COLLECTOR OR BETTER COLLECTOR
SHEATHING SOLENE BRAND TILES
Q � � COLLECTOR ///
W o m COLLECTOR
i vBARREL
v) ¢ TILES
wOz
z O 3" 3„ WOOD TRUSSM #2 SYP ::. REC111309
N0
o z 3„ OR BETTER 3" \\ ROOF ;, ALE NOTED
O U O >� SHEATHING
3 Uo 4X LOCATE BETWEEN ROOF
Q z Z TRUSSES AND NAIL SHEATHING `
o w < WITH 4 16D SEE NOTE 3
(J z z NAILS AT EACH END" DIA STAINLESS" DIA STAINLESS O X DIA S NLESS STL LAG BOLTS AT EACH STL LAG BOLTS AT EACH NOTE: CUT OUT OR REMOVE NOTE: CUT OUT OR REMOVE
z z NOTE: ROOF FINISH STL LAG BOLTS AT EACH SOLENE BRAND CONN TYP. WOOD TRUSS TILE TO INSTALL STANDOFF" DIA STAINLES
SOLENE BRAND CONN TYP. STL LAG BOLTS AT EACH TILE TO INSTALL STANDOFF o
U OMITTED FOR CLARITY SOLENE BRAND CONN TYP. NOTE: ROOF FINISH SYSTEM #2 SYP ASSY. THEN REINSTALL TILES ASSY. THEN REINSTALL TILES
OMITTED FOR CLARITY SOLENE BRAND CONN i�
z MISSED TRUSS SOLENE OR BETTER HARDWAREOUNTING TYP• HAROUND ARDWARE
19
Lu 3 BRAND NAILER INST. SHINGLE METAL 5 FLAT CONC. TILE ROOF
Z � � DRAWING N0.
UWw 4 BUILT UP ROOF (6BARREL TILE ROOF Z>SCALE: 1-1 2"=1'-0" L-30 0 0 / L-3 SCALE: 1-1/2"=1'-0" SCALE: 1-1/2"=1'-0"SCALE: 1-1 /2"=1'-0"
c-4 U Q SHEET 1 OF 1