Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SUBMITTED PAPERS
I 'i R OFFICE USE DATE- 'FILED: PLAN REVIEW FEE: _tQ lV 10. RECEIPT NO.: CONCURRENCY FEE: RECEIPT NO.: n l� PERMIT NUMBER: �,�/I 'yyy CERT. CAP. NO.: ALL INFO MUST BE COMPLETE & FILLED IN TO BE ACCEPTED PLANNING & DEVELOPMENT SERVICES DEPARTMENT BUILDING & CODE REGULATION ISION SCANNED 2300 Virginia Avenue By St Lucie County Ft. Pierce, FL 34982-5652� 772-462-1553 RON _Z �� 6- _ APPLICATION for BUILDING PERMIT C-"".. — CERTIFICATE of CAPACITY/ZONING COMPLIANCE PROJECT INFORMATION v 1. *LOCATION/SITE ADDRESS: 5V2 SP'�OU� 2. J' PROJECT NAME: JJ)/T/O SITE PLAN N 8 WrrD/ki 3. g PROPERTY TAX ID #: /9/2 —S 4. LEGAL DESCRIPTION (attach extra sheets if necessary): 5. PLAT BOOK 6. PAGE NO. 7. BLOCK NO. 8. LOT NO. C-Pb 9. # PARCEL SIZE (ACRES/SQ FT.): �Z — LOT DIMENSIONS: !/✓ X °¢ x /' '� 66°01' 10. d COMPLETE DESCRIPTION OF CONSTRUCTION PROJECTOR WORK ACTIVITY: 4 9J1 r/w e1117; Z r Gt,Jil C/.-d-= Vic% D11noPh1770&J c9� 5X1f17Af6 &QVJ,67 4j 2120ylb6�D '/ F100L P1.4A1 —AleU,I 0VI r76" aM `_ 'ei: -° a� 64s C4V*PWC7) n SlAk 11. SETBACKS (ACTUAL) FRONT: NV-)_ BACK: RIGHT SIDE LEFT SIDE: _ 12. *TYPE OF CONSTRUCTION (Check all appropriate boxes) ] NEW CONSTRUCTION [1j'_EXPANSION/ADDITION [ ] INTERIOR RENOVATION ] RESIDENTIAL [ ] COMMERCIAL [ ] INDUSTRIAL [ ] OTHER (SPECIFY) 13. DESCRIPTION OF PROPOSED USE: %d��/� 14. ® SQ. FT OF CONSTRUCTION: �� 15. SF. FT 1 st FLOOR: 16. VALUE OF CONSTRUCTION: $ 6, 000 The value of construction is used to determine the amount of permit fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction activities. If the value is $2500 or more, a RECORDED Notice of Commencement must be submitted with this application. SLCCDV Form No.: 001-02 I C.c- v/QL0F,326 I UPDATED 6/25/09 OWNER INFORMATION NAME: &1210�vzll) ADDRESS: CITY:�� /�%�/� STATE: ZIP: .�¢V57 ��- / PHONE (DAYTIME):� 72-/ � Email: AD/j9 IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE, PLEASE FILL IN NAME AND ADDRESS BELOW. FEE SIMPLE TITLEHOLDER: ADDRESS: CITY: STATE: ZIP: PHONE (DAYTIME): CONTRACTOR INFORMATION ST. of FL REG.CERT #: ST. LUCIE COUNTY CERT #: BUSINESS NAME: QUALIFIERS NAME: ADDRESS: CITY: STATE: ZIP: PHONE (DAYTIME): FAX NO. Email: j ARCHIVENGINEER: 'J� S-0/-/ lg 5'1L/ ADDRESS: e9'41-1 CITY: V L—%2O /3 60C4� STATE: FL ZIP:.?2f6 PHONE (DAYTIME): L� -%� - 2—5 BONDING COMPANY: ADDRESS: CITY: STATE: ZIP: MORTGAGE LENDER: ADDRESS: CITY: STATE: ZIP: IMPORTANT NOTICE: When a permit is issued and it is not picked up within 60 days after notification it will be voided and returned to you by mail. i r� CERTIFICATION: This application is hereby made to obtain a permit to do the work and installations as indicated, and to obtain a certificate of capacity, if applicable, for the permitted work. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits may be required for ELECTRICAL, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AND AIR CONDITIONERS, FENCES, ETC., not otherwise included with this building permit application. St. Lucie County makes no representation that its granting of a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Homeowner Association rules, bylaws or any covenants that may restrict or prohibit such structure. Please consult with your Homeowner's Association and review your deed for any restrictions which may apply. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures (all types), swimming pools, fences, walls, signs, screen rooms, utility substations & accessory uses to another non- residential use. NOTICE TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOBSITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE TO APPLICANT: IF IT IS NOT YOUR RIGHT, TITLE, AND INTEREST THAT IS SUBJECT TO ATTACHMENT: AS A CONDITION OF ISSUANCE OF THIS PERMIT, YOU PROMISE IN GOOD FAITH TO DELIVER A COPY OF THE CONSTRUCTION LIEN LAW NOTICE TO THE PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT. OWNER OR CONTRACTOR SIGNATURE ,, CONTRACTOR SIGNATURE STATE OF FLORIDA 4. COUNTY OF The foregoing instrument was acknowledged before me this day of by_�% who is personal own or has produced as identification. Signature of Not STATE OF FLORIDA COUNTY OF m 0 a X -< c The foregoing o�o mcn me this cam= by `� GG who is' rson acknowledged before 20 , known or has produced of Notary as identification. Commission No. (Seal) Commission No. (Seal) NOTE: TWO (2) SIGNATURES ARE REQUIRED. EACH SIGNATURE MUST BE NOTARIZED. IF APPLYING FOR THIS BUILDING PERMIT AS AN OWNER/BUILDER, THE OWNER MUST PERSONALLY APPEAR _TO SIGN THIS APPLICATION IN THE OFFICE LISTED ON THE, FRONT OF THIS APPLICATION. OWNER BUILDER AFFIDAVIT WILL BE REQUIRED FOR ALL OWNER/BUILDER APPLICANTS. ' For specific instructions see appropriate permit hecklist. i i OFFICE USE ONLY BP ##: ��• J©�cr SECTION ' TOWNSHIP RANGE MAP NO. (� ZONING LAND USE ( LOT CVG'%;w�® TAZ NO. FLOOD ZONE FIRM MAP # 1ST FLR ELV MAX HGT CONST TYPE OCCUP TYPE MAX OCCUP # OF FLRS WATER SEWER SPRINKLERS STORM WATER 0 LOT OF REC LOT OF REC LOT SPLIT LOT SPLIT Before 1/1990 After 1/1990 REQUIRED APPROVED REPORT HABITABLE RADON PERMIT CODE �y� AREA FEE E `�1 RADON LIBRARY PUBLIC BLD UBIC BLD PARKS IMPACT IMPACT FEE IMPACT IMPACT FEE CORREC FEE FEE GENERAL SCHOOL ROAD CREDIT Y • N LAW ENF IMPACT IMPACT IMPACT FEE FEE FEE FIRE/EMS DRIVEWAY Y N DRIVEWAY ADMINISTRATIVE IMPACT REQUIRED FEE VARIANCE FEE FEE SPECIFY MECHANIC ROOF NON -CONFORMING MISCELLANEOUS SUBS ELECTRIC Z GAS LOT OF RECORD FEES REQUIRED PLUMBING FEES 0 DATE SENT TO ADDRESSING: / REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE COUNTS REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE RECEIVED I DATE COMPLETED INITIALS r r r- �i��Lsr/Lr UOr Planning & Development Services Review Comments for Owner Building &Code Regulation Division Permitting Department 2300VirginiaAvenue Page 1 Fort Pierce, FL 34982 12/03/2012 ROBERT BRITTON 5812 SPRING LAKE TERR FORT PIERCE, FL 34951 Permit Number: 1211-0085 As of today's date your Contractor is being notified along with yourself that the referenced building permit has some issues listed in the comments below. We have asked that these issues be dealt with as quickly as possible so that we are able to continue to process this permit in a timely manner. This information is being shared with you so you are aware of the status of your permit. PROPERTY INFORMATION 5812 Spring Lake Ter FORT PIERCE 34951 APPLICATION INFORMATION Permit Number: 1211-0085 Activity Type: Addition Permit Type: Building (Miscellaneous) CONTRACTORS INFORMATIOA Application Type: Master Permit w/subs Other Activity: Stories 1 REVIEWS AND COMMENTS Review Tyne Status Reviewed By Date Started Date Complete Date Released Documents Missing Pending Audrey Humphrey 11/07/2012 1 Comment please contact owner by e-mail. 11/20/2012 2 Comment VEGETATION PERMIT'IN DRAWER UNDER B FOR BRITTON NO FEES DUE. Review Type Status Reviewed By Date Started Date Complete Date Released Front Counter Review Complete Audrey Humphrey 11/07/2012 11/07/2012 Review Type , Status Reviewed By Date Started Date Complete Date Released Plans Examiner Review Pending Dave Johnson 12/03/2012 12/03/2012 1 Comment PROVIDE ENERGY CALC'S AND MANUAL J CALC'S FOR NEW CONDITIONED SPACE. 402 & 403.6 FBC, ENERGY ��f zriLPi UOvmu2 Planning& Development Services Review Comments for Owner Building & Code Regulation Division Permitting Department 2300 Virginia Avenue Page 2 Fort Pierce, FL 34982 o ram....,., -m PRO\/Ir1F PROfU IRT APPRO\/AI FOR ROOFING. MATERIAL. R 904 FBC 12/03/2012 3 Comment TRUSS DRAWINGS MUST BE REVIEWED AND SIGNED BY ENGINEER OF RECORD. 61G15-30.005 FAC 12/03/2012 4 Comment PROVIDEAC PLAN IN DUPLICATE. 107.2.1 FBC Review Type Status Reviewed By Date Started Date Complete Date Released To Be Reviewed by Zoning Complete 11/16/2012 Review Type Status To Be Review by Plans Exan Complete Reviewed By Date Started Date Complete Date Released 11/26/2012 Review Type Status Reviewed By Date Started Date Complete Date Released Zoning Review Complete Lydia Galbraith 11/16/2012 11/20/2012 Planning & Development Services' Building & Code Regulation Division Permitting Department 2300 Virginia Avenue Fort Pierce, FL 34982 12/03/2012 ROBERT BRITTON 5812 SPRING LAKE TERR FORT"PIERCE; FL 34951 Review Comments for Owner Page 1 Permit Number: 1211-0085 As of today's date your. Contractor is being notified along with yourself that the referenced building permit has some issues listed in the comments below. We have asked -that these issues be dealt with as quickly as possible so that we are able to continue to process this permit in a timely manner. This information is being shared with you so you are aware of the status of your permit. PROPERTY INFORMATION 5812 Spring Lake FORT PIERCE 34951 APPLICATION INFORMATION Permit.N umber: 1211-0085 Activity Type: Addition Permit -Type: Building (Miscellaneous) REVIEWS AND COMMENTS CONTRACTORS INFORMATIOA Ter Application Type: Master Permit w/subs Other Activity: Stories' 1 Review Type Status Reviewed By Date Started Date Complete Date Released Documents Missing Pending Audrey Humphrey J 11/07/2012 1 Comment please contact owner by e-mail. 11/20/2012 2 Comment VEGETATION PERMIT IN DRAWER UNDER B FOR BRITTON NO FEES DUE. Review Type Status Reviewed By Date Started Date Complete Date Released Front Counter Review Complete Audrey Humphrey 11/07/2012 11/07/2012 . Review.Tvpe Status Reviewed By Date Started Date Complete Date Released, Plans Examiner Review Pending Dave Johnson 12/03/2012 12/03/2012 1 Comment PROVIDE ENERGY CALC'S AND MANUAL J CALC'S FOR NEW CONDITIONED SPACE. 402 & 403.6 FBC ENERGY Planning &-Development Services Building & Code Regulation Division Permitting Department 2300 Virginia Avenue Review Comments for Owner Page 2 12/03/2012 2 Comment PROVIDE PRODUCT APPROVAL FOR ROOFING MATERIAL. R 904 FBC 12/03/2012 3 Comment TRUSS DRAWINGS MUST BE REVIEWED AND SIGNED BY, ENGINEER OF RECORD. 61 G15-30.005 , , , FAC 12/03/2012 4 Comment PROVIDE AC PLAN IN, DUPLICATE. 107.2.1 FBC Review.Type Status . Reviewed By Date Started Date Complete _ Date Released To Be Reviewed by Zoning Complete 11/16/2012 Review Type Status Reviewed By Date Started Date Complete - Date Released To Be Review by Plans Exan Complete 11/26/2012 Review Type Status Reviewed By Date Started Date Complete Date Released Zoning Review Complete Lydia Galbraith. 11/16/2012 ' 11/20/2012 9 Lydia Galbraith From: Lydia Galbraith Sent: Monday, November 19, 2012 10:25 AM' To: 'ROBERTBRIT@aol.com' Subject: RE: 1211-0085 addition Mr. Britton, Thank you for your response. The St Lucie County requires up to date signed and sealed surveys for all construction with a valuation over $ 10,000.00. The submitted survey has the proposed addition drawn in. Any changes to an original survey drawn in will void the seal of the survey. The surveyor has to add the proposed structure and additional requested information officially to the survey. Setbacks are required to be measured from the proposed addition. If you have any questions, please let us know. Thanks, Li�d�a g ca�brarth Planning Technician Planning and Development Services Phone: (772) 462-1555 Fax: (772) 462-6448 Email: galbraithl stlucieco.org From: ROBERTBRIT@aol.com [mai Ito: ROBERTBRIT@aol. com] Sent: Friday, November 16, 2012 2:20 PM To: Lydia Galbraith. Subject: Re: 1211-0085 addition Dear Lydia, Thanks for your update. Please check the fact that the surveying was properly submitted at the time of documents reviews. The given information has the dimension of the intended addition. You can also see inside the floor plans a complete set of information. The plans are signed. Robert Britton In a message dated 11/16/2012 9:24:10 A.M. Eastern Standard Time, galbraithlC�stlucieco.org writes: Mr. Britton, Attached the Zoning review comments. The file will be forwarded to the plans examiner for review. If you have any questions, please let us know. a Thanks, L�Act g caLbraLth Planning Technician Planning and Development Services Phone: (772) 462-1555 Fax: (772) 462-6448 Email: galbraithl aastlucieco.org Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records available to the public and media upon request, It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and / or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error, please notify the sender by reply e-mail and delete all materials from all computers. Lydia Galbraith From: Lydia Galbraith Sent: Friday, November 16, 2012 9:22 AM To: 'robertbrit@aol.com' Subject: 1211-0085 addition Attachments: DOC 1211-0085.pdf Mr. Britton, Attached the Zoning review comments. The file will be forwarded to the plans examiner for review. If you have any questions, please let us know. Thanks, t_iUdLa g GaLbratth Planning Technician Planning and Development Services Phone: (772) 462-1555 Fax: (772) 462-6448 Email: galbraithl(d)stlucieco.om Planning & Development Services Building & Code Regulation Division Review Comments Permitting Department 2300 Virginia Avenue Fort Pierce, FL 34982 Page 1 Phone: (772) 462-1553 Fax: (772) 46271678 PROPERTY INFORMATION Address: 5812 Spring Lake Ter City / State I Zip; FORT PIERCE Parcel # : 1312-502-0148-000/1 Zoning: PUD APPLICATION INFORMATION Permit Number: 1211-0085 Activity Type: Addition Permit Type: Building (Miscellaneous) CONTRACTOR INFORMATION Contractor Name: Business Name: Business Addr: City / State / Zil FL 34951 Jurisdiction: St. Lucie County Lot # : 398 Block: Owner(s): ROBERT BRITTON LOURDES J BRITTON Application Type: Master Permit w/subs Other Activity: Stories:_ 1 Automatic Sprinkler System? Fax Number - - REVIEWS AND COMMENTS Review Type Status Reviewed By Date Started Date Complete Date Released Documents Missing Pending Audrey Humphrey 11/07/2012 1 Comment please contact owner by e-mail. Front Counter Review Complete Audrey Humphrey 1.1/07/2012 11/07/2012 To Be Reviewed by Zoning Complete 11/16/2012 To Be Review by Plans Exar Pending Zoning Review Incomplete Lydia Galbraith 11/16/2012 Planning & Development Services Building & Code Regulation Division Review Comments Permitting Department 2300 Virginia Avenue Fort Pierce, FL .34982 Page 2 Phone: (772) 462-1653 Fax: (772) 462-1578 11/1R/7n17 1 rnmm-ni THE VALUATION OF CONSTRUCTION IS BASED ON THE SCHEDULE OF THE INTERNATIONAL BUILDING CODE. THE TOTAL COSTARE BASED ON LABORAND MATERIAL NOT INCLUDED THE VALUE OF THE LAND. FOR SINGLE FAMILY HOMES ORADDITIONS THE BASE IS $ 102.91 PER SQUARE FOOT. BASED ON THIS INFORMATION THE VALUATION OF PROPOSED CONSTRUCTION IS GOING OVER THE $ 10,000.00 WHICH REQUIRES AN UP TO DATE SIGNEDAND SEALED SURVEY. THE SURVEYS IS REQUIRED TO INCLUDE THE PROPOSED ADDITION WITH DIMENSIONS, SETBACKS TO THE PROPOSED STRUCTURE AND PROPOSED FINISHED FLOOR ELEVATION. PLEASE PROVIDE THE FLOOR ELEVATION OF THE EXISTING HOUSE AS WELL. THE FLOOD ZONE INFORMATION IS REQUIRED TO BE BASED ON THE FEMA FLOOD ZONE MAPS ISSUED AT 2/16/2012. PLEASE PROVIDE TWO SIGNED AND SEALED UPDATED SURVEYS. 11/16/2012 2 Comment PLEASE BE AWARE THATABOVE COMMENTS ONLY REFLECT THE ZONING REVIEW. THE PLANS EXAMINER MIGHT HAVE ADDITIONAL COMMENTS. PLANNING & DEVELOPMENT SERVICES DIVISION BUILDING & CODE REGULATIONS DIVISION 2300 Virginia Ave Fort Pierce, FL 34982 BUILDING PERMIT SUB -CONTRACTOR SUMMARY will be using the following sub -contractors for the (Company/I fvt ume) �%&�/_ project located at 2_ L'4 �� A CF7Z-C�F ¢� , (Street : or Property Tax ID #) It is understood that if there is any change of status regarding the participation of any of the sub -contractors listed below, I will immediately advise the Building and Zoning Department of St. Lucie County. Trade Name of Company/Contractor St. Lucie County/ State of Florida License Number Electrical Plumbing HVAC/ Mechanical Roofing Gas OFFICE USE: ONLY: PERMIT ISSUE DATE: NUMBER: PLANNING & DEVELOPMENT SERVICES DEPARTMENT BUILDING & CODE REGULATIONS DIVISION BUILDING PERMIT SUB -CONTRACTOR AGREEMENT St. Lucie County Contractor Certification Number: State of Florida Certification Number (If applicable): Z3'� 7 A—) have agreed to be the (Company Name/IfiW' al a"Tn ,QP,A)�r sub -contractor for ode) for the project located at CY (Primary Contractor) (Project Stree dres Property Tax ID #) It is understood that, if there is any change of status regarding our participation with the above mentioned project, I will immediately advise the Building and Zoning Department of St. Lucie County by personally filing a Change of Contractor notice. (Form: SLCCDV No. 004-00) BUSINESS QUALIFIER (Name of the Individual shown on the Contractor's License) 11 Business Name: Address: City/State/Zip: Phone: OFFICE USE ONLY: r� DYAN i %— yuud email: %2-/- 4401 PERMIT # ISSUE DATE 0 PLANNING & DEVELOPMENT SERVICES DEPARTMENT BUILDING & CODE REGULATIONS DIVISION BUILDING PERMIT SUB -CONTRACTOR AGREEMENT St. Lucie County Contractor Certification Number: State of Florida Certification Number (If applicable): ®� have agreed to be the (Company NaTe'thrd' i dua ame) 4 V FW_. sub -contractor for fpperof�,ade) for the project located at (Primary Contractor) S�l2_ S /PGU,tOG --)—A lee-- 72Rz (ProjectcStree_,�qAddrtess or Property Tax ID #) It is understood that, if there is any change of status regarding our participation with the above mentioned project, I will immediately advise the Building and Zoning Department of St. Lucie County by personally filing a Change of Contractor notice. (Form: SLCCDV No. 004-00) BUSINESS QUALIFIER (Name of the Individual shown on the Contractor's License) ORIGINAL SIGNATURES ARE REQUIRED y. ERRERRINT NAMEp.i Business Name: Address: City/State/Zip: Phone: /ZZ 3P41,0G G4/4€ 7�a/Z �. E ;Z110ecer' 3o�T-r U- 4¢.3/ email: RD.QE/riZGT IE40,e OFFICE USE ONLY: PERMIT # ISSUE DATE PLANNING & DEVELOPMENT SERVICES DEPARTMENT BUILDING & CODE REGULATIONS DIVISION BUILDING PERMIT SUB -CONTRACTOR AGREEMENT St. Lucie County Contractor Certification Number: State of Florida Certification Number (If aapplpliccaablle/): have agreed to be the (Company Name/ #iuid ame) sub -contractor for a([Tf Tr (Primary Contractor) for the project located at c/Z 5�,.�/ ZQ A4er Tit? (ProjeoStree g�aor Property Tax ID #) It is understood that, if there is any change of status regarding our participation with the above mentioned project, I will immediately advise the Building and Zoning Department of St. Lucie County by personally filing a Change of Contractor notice. (Form: SLCCDV No. 004-00) BUSINESS QUALIFIER (Name of the Individual shown on the Contractor's License) //Ut'/2 .sue Business Name: Address: City/State/Zip: Phone: `�012 ./lulu- ::�44r r& . OFFICE USE ONLY: S 72l 44-43/ email: PERMIT # ISSUE DATE St. Lucie.CL---;y Building & Zoning Department 2300 Virginia Avenue Fort Pierce, Florida 34982 (772)462-1553 OWNER/BUILDER. AFFIDAVIT DISCLOSURE STATEMENT F.S. 489.103 (7) EXEMPTIONS St_ate law requires construction to be done by licensed contractors.- You have applied for a permit under an exemption to that law. The exemption allows you, as the owner of your property, to act as your own contractor even. though you do not have a license. You must provide direct, on -site supervision of the construction yourself. You maybuild or improve farm outbuildings, a one -family or two-family residence or -a commercial building at a cost -of under $75,000.00. The building or residence must be for your own occupancy. It may not be built or substantially _ = improved for sale or lease._ If y_ou sell or lease_ a buildingyouu have built_or Substantially_ improved yourself within___ _ -- - -- - one year after the construction is complete, -the law will presume that you built or substantially improved it for sale or lease, which is a violation of this exemption. You may not hire an unlicensed person to act as your contractor or to supervise people working on your building; it is your responsibility to make sure that people employed -by you have licenses required by state law and by county or municipal licensing ordinances. You may not delegate the responsibility for supervising work to a licensed contractor who is not licensed to perform the work being done. Any person working'on your building Who 'is not licensed must work under your direct -supervision and must be employed by -you, which means that -you. must deduct F.I.C.A. and withholding tax and provide workers' ---- --compensation-for that -employee -all -as -prescribed -by-law: Your construction -must comply -with-all-applitzableJaws;' - ordinances, building codes, and zoning regulations. Initiate I understand that the building official and inspectors are not there to design or give advice on howto feet the minimum code. Initial.* I understand that as an owner -builder that any contract disputes with sub -contractors and I must be handled in a civil court with the advice of an attorney. This department will not mitigate any contract disputes. Initial . I understand that if I compensate any person or company for work performed they are required to be licensed in this jurisdiction. If for some reason they do not possess a license, I may be responsible and liable bor the cost of the license. Initial I understand that if any person that is unlicensed and uninsured gets injured on my construction project - they may be entitled to workmen's compensation. I could be held liable for all doctor, lawyer and related me 'cal cost, which could include loss of wages during recovery from their injury. Initial To qualify for this exemption under this subsection, an owner must personally appear and sign the building permit application and initial the above. I hereby acknowledge that I have read and understand the above disclosure statement and that I further understand that any violation of the terms of the owner/builder exemption shall be reported by the Building and Zoning Department to the Florida State Department of Professional Regulation.. Signed and acknowledged on this day of of 20. 6Awnegr/13ui41der Signature r STATE OF FLORID�A* COUNTY OF - e 1 ne foregoing instrument was acknowled eci before me ttds 5 day of *?70,&L-` who is personally own to me, or who has produced asi ation. ,t u/mIr-p ppy (Seal) ,R I�•., AUDREY B. HUMPHREY i' MY COMMISSION # EE 061159 '- :o< EXPIRES: March 6, 2015 '�PF qQ•' Bonded thru Notary Public Underwriters 1Z Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Ave Fort Pierce, FL 34982 772-462-1553 -DISCLOSURE-STATEMENY. -F.S.--489303 -(6)'JEnIVIPTIONS State law requires electrical contracting to be done by licensed electrical. contractor ' s. You have applied fora permit under an exemption to -that law. The exemption allows you, as -the owner of your property,*to act -as -your -own ePe6ifiCaf-c--oiftfd&t6r--6ve-n' thoughyounot have alibbil§d. You may install electricatwiring for -a farmoutbuilding or a- commercial d e aggregate or duplex residence. u may install electrical wiring in a co rffi building I aggr6g - construction costs of which are under $75,000. The home or building must be for your own use and occupancy. ^It may not be built for sale or lease. If you sell or lease more than one building you have -wired yourself within I year after the construction is complete, the law will. presume.that you built it for sale or lease, which- is a violation of this exemption. You may not hire an unlicensed person as your electrical contractor. Your construction shall be done according to building codes and zoning regulations. It is your responsibility to make sure that people employed by you have licenses required by state law and by county or municipal licensing ordinances. Failure to do so may result in a liability for you! To qualify for this exemption under this subsection, an owner must personally appear and sign the building permit application. I hereby acknowledge dge that I have read and understand the above disclosure 'statement and that I further ,understand that -a-i--!-y -' violation o e e f th' terms of the owner/builder exemption -shall be reported by the, Community Development Dire tor to the Florida State Department of Professional Regulation. Signed and acknowledged on this day of 9 STATE OF FLORIDA COUNTY OF The foregoing instrument was acknowledged before me this 15- day of 20 by who is personally to me or has produced as Identiflcation. 9 5'. cal 8MM Signature of ry Print name of Notar3( V Title: Notary Public Commission Number SLCPDSD Revised 7/23/2010 St Lucie County Owner Builder Affidavit -Electrical Contracting PLANNING & DEVELOPMENT SERVICES DEPARTMENT BUILDING & CODE REGULATIONS DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 (772)462-1553 FILLED LANDS AFFIDAVIT I, the undersigned, am the owner of the following described property, (Parcel Id#/Legal description/ d�d ea' s) for which I have applied to St. Lucie County for a Final Development Permit. In accepting this Final Development Permit, BP Number , I acknowledge that as owner of the above described property, and in accordance with Section 7.04.01(D), St. Lucie County Land Development Code, I shall be responsible for assuring adequate drainage so that the immediate community WILL NOT be adversely affected. I further acknowledge that in granting this permit for the development of this property, St. Lucie County is neither obliged nor liable to provide for, or maintain in any form, adequate drainage off my property which will not adversely affect the immediate community. STATE OF FLORIDA, COUNTY O ACKNOWLEDGED BEFORE ME THIS DAY OF / / V 20 /4S_ BY J6 / JM% �/ I� �I�%i WHO IS PERSONALLY�KNOWI�TO ME OR WHO HAS PRODUCED ARY PUBLIC COMMISSION NUMBER SLCPDSD Revised 08/24/2010 AS IDENTIFICATION. )a �- A TYPE QFRdPRINT NOTARY (SEAL) ti...... AUDREY B. HUMPHREY ;;q = MY COMMISSION # EE 061159 ;,; EXPIRES: March 6, 2015 . Iof ... Bonded Thru Notary Public Underwriters .• JOSEPH E. SMITH, CLERK OF THE CIRCUIT COURT - SAINT LUCIE COUNTY FILE # 3766364 Ca NOOK 3450 PAGE 2572, Recorder-1/06/2012 at 11:53 i11 NOTICE OF COMMENCEMENT Permit No. Tax Folio No. 13/2— SQL - "d- "15CO.r 1 State of Florida County of St. Lucie The undersigned hereby gives notice that Improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. Legal Description of Property: (and street address if available): 6-8/4 SRuad 44x6 719=CE VC)(z FU N* GUT 3R& o. General description of improvement: Owner Information or Lessee Information if the Lessee contracted for the Improvement: Name 1W,0a77t7 /3R. IVAJ Address 59/2— g;_>9 UG G.A,FF 7; C• Interest in property: Name and address of fee simple titleholder (if different from Owner listed above): Contractor's Name: owyleg r/ sui ) beie Contractor Address: Phone Number: Surety (if applicable, a copy of the payment bond is attached): Amount of bond: $ Name and address: Phone number: Lender h Lender's Number: Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes: Name: Phone Number: Address: In addition to himself or herself, Owner designates of Uenor's Notice as provided In Section 713.13(1)(b), Florida Statutes. Phone number of person or entity designated by owner: to receive a copy of the Expiration date of notice of commencement: (the expiration date may not be before the completion of construction and final payment to the contractor, but will be 1 year from the date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENTARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury, I declare that I have read the foregoing notice of commencement and that the facts stated therein are true to the best of my knowledge —and ellef re essee, ner's or Lessee's Authorized Officer/Director/Partner/Manager AUMREYB.HUMPHREY (Signatory's Title/Office) MYCOMMISSION11EE061159 EXPIRES: March 6, MIS g � y 01 . 0 , , BondedThru Notary PobAcUndenn9ers The foregoingl,instrument was acknowledged before me this day of UY /lV 20 ByIY"%� i T! Vy) as &drib for Name of Person Type of authority (e.g.officertrustee) Party on behalf of whom Instrument was executied Personally known produced Identification_. "nhf (Signature of Not Public - State of Florida) (� (Print, Type, or Stamp Commissioned Name of Notary Public) Type of Identification produced STATE OF-FLORIDA ST. LUCIE COUNTY THIS ISTOCERTIFYT ATTHISISA TR A " ORRECT OP Of O L. R Iit tH f1�91 C E K r/ 'U6 l Date- i!7v-� Spercc-Abcwe Tkis Uas F or Remg Data) This Wamrmt Deed mama tis24th day oti Aonk 2612, by Patryk Mierzejewski and Paula Mierzejewski flkla Paula AH)srfii, vtikot—,_ post c4ficas a is 112440 Si Plandome Dr., Hobe Sound,. FL 33455 grantor, to Robee, smote and _Lqurdes�.3b��a BA don, hus#saand,and,'Wife, vihose post orrice address is 5812 Spring' Lake Ter, Ft Pierce, 'FL 349516`grGn ee: (Whenever used herein the terms "grantor' and "grantee" include all the parties to this instrument and the heirs, legal representatives, and assigns of individuals, . and the successors and assigns of corporations, trusts and trustees) ' . Witnesseth, that said grantor, for and in consideration of the sum of TEN AND NO/100 DOLLARS ($10.00) and other•good and valuable considerations to said grantor in hand paid by said grantee, the receipt whereof is hereby acknowledged, has granted, bargained, and sold to the said grantee, and grantee's heirs and assigns forever, the following described land, situate, lying and being in the St. Lucie County, Florida, to -wit: �4 Lot 398, Portofino Shores -Phase Two, according to the Plat recorded in Plat Book 43, Page 33, as .J recorded in the Public Records of St. Lucie County, Florida. 9 --Parcel Identification Number: 1312-502-0148-000-1 *The ?,3roPerty described in this instnunent is not the homestead of the 4-4 crrantors who maintain their homestead at 12440 SE Plandarne Drive, Hobe Sound, FL 33455 MTogether with all the tenements, hereditaments and appurtenances thereto belonging or in anywise appertainirfg. 0 To Have and to Hold, the same in fee simple forever. And the grantor hereby covenants with said grantee that the grantor is lawfully seized of said land in fee simple; that the grantor has good right and lawful authority rity to sell and convey said land; that the grantor hereby fully warrants the title to said land and will defend the same against the lawful claims of all persons whomsoever; and that said land is free of all encumbrances, except taxes for the year of closing and subsequent years, restrictions, o reservations, coven and easements of record, if any. ro In Witn feo g antor has her rantor's hand and seal the day and year first above written. ro `n Sig d, seat red i r presence: rg ro Witness i ssNate, o Pri ed Na \ , may: --. Pat ierzejewsk' t _ o' Witne Nam < APrinted Name. N .rq Paula Mierzejewski rd r * County of The foregoing instrument was acknowledged before me this ��ay of b'1 L� by , Patryk Mierzejewski and Paula Mierzejewski f/k/a Paula Albe nally known to me or (=) have produced n _,-4,.c i A LLyn i s identification. , ftft no FL 24ft2 CERTIFICATE OF'RMZTE TREATMENT CO ►" 'NUJ TTON IL' 94TWNT PERMIT #._1I U - b I P �BUILDER����C�Q�� EST CQ( PESr CONTROL UCENS VIM, / i ..t SUbWmnW fermi4es In amordenm vw11b the smote Noorm, psm AseaciWonfor 'ercenMge of 9ok, ►abe o1' Tkfttm inmo of 7vm*awlt,., / r - — Fooftg ---..�.1* ,Re-Trea Dfkftey ._�__..161 TF estmmt ,Re-TrW •.. ottw ---_� "Tneaftert ._. _ Re Treat �eTmm ma* mftr for Rnai Insp000n C . Si of ina�or e; 77�er�must,die,ea�p,�a,l�',r+�gtibaa►a►re�',�,trw�►�f'eye,�j,�,�nm,m��`,f�atlhe;,,ii�b op by the mt fine Of040 AMmmcMn arrm0 &jA q /hwp&%w w,�l t�fOsnn►�►,re•1� i1ft ,2,s JJWWW& arP� 7MOM 1ial',�Jt9i�/hpgrl aft A wa�ar'/nd•,1�'�r �: �4/nk�t1 t+�q► � el�J ttwin4� of R � birer�t, trie.aq�+ k�r/Di nt�r', +ieaa►Ibr'tetm�ue► 'c' � i► a ' �a+aoralof p�-�.�ie/�„*,,� �,1�isr�p 1,�•ardeat�7�entsarist/ _.SMWWto b® p1wW an PAGE 01/01 louthcoast Pest Eontrol 1149 &W AtH9VRe Ave '} 84. Usie, FL 34453 772-411-1919 (�Ty CERTIFICATE OF TERMITE TREATMENT CONSTRUMON SOIL TREATMENT PERMIT #: S�20 032a JOB BUILDERJCONTRACTOR: otir PEST CONTROL CONTRACTOR: PEST CONTROL LICENSE #: We, the undersigned, hereby c er* that we have pretreated the above dexAbed n for subeerranean termites in accordance with the standards of the National Pest Control Assadatlon. Square feet if area t�reted: Percentage of solution: ©ate of Treatlnent: Footing _,.,10 Treabrient _fie -Thy _1-4 Treatment -Re-Treat .19 Treatment Re -Treat Che ksh used: CrasSh e_. c� Total gallons used: Time of Treabnent: lJ!YK - �a L-1''Theatnent —Re•Tneat ..� ..pools . ---ATreatment ALL -Trent. Perimeter for F.Inal, hupemon /4ro� Thera mtat b� a aoimpk�d �[artn /b' e�rh rags,�ie+d Grsranait arm-rtt arld b7tr lbrrrt mtaatbe art bhe�ob rw � aP by ilea in�oalnr at e� of eaa►i bi;pa�ari aw the s�de�dtrled tn�oerDtart rr� I bs7xiid a re�rq>e�brt PSCilD L5 car ca&-°af!°iVAMM+e DW&A t hrprVMWOfi of ftWA x A MOWrrsis t PV0 board sM11V pM*w!b're' a e apibi6 7ieaft" tCerGO' ratrs"as M* ftopmtb: car>;o ,, a ogoyhrftpnrsan akp&7)ats beeued t0 -F 4 rao.!P, wp ►/brft pent>.i1Am 7Tie the &"X Ce►fale�prwe d►COW* wet ifo� iWoflf appl r, bmmrardda* alb* bneebnnn� s�e.for�etaay avaa b'eAN4 dxmkil US* peha N mnharrftaw ared liwftb of -gabs aced, to estabA* a twffatk t1cmd cf Drvaead4sb:�bnien� ff�+e.s�o�dkrtt�tca/batr�►'me<tha�dJiarrt�ennXe/ansrerltbnEsuee+d, l�r�/Cxie�rbtybl�e�rxshaQ be aangoklydpn1 tD t�l bum 4tpnw/. St Lucle County requires for the final In for CO, a 11w nanent Sticloar to be planed on 0". tD 00 ED lL W E L C W E .0 UO Port St. Lucie Building Department Certificate of Compliance (This is a partial treatment only and not a guarantee or warranty) Permit Number: 12- // --Od66- This form is to be filled out by Pest Control Company Location of Property: 1�VOI <Pak�Lxui- Legal Description: Section Pest Control Company 'I—e4Cj nP t3C,6A e f-/; G,CA Company owner - Please Sign Date Title Soil Treatment Company Information Soi Treatment Company Name av se- psc.. ?LA?Xf- Address , 2 me Soil Treatment/DACS License # The building has received a complete treatment for the prevention of subterranean termites. Treatment is in accordance with the rules and laws established by the Florida Department of Agriculture and Consumer Services. A second treatment was done on (date) as per manufacturer's specification. If the second treatment is not required, a copy of the product label shall be included with this certificate. Block Lot Treatment Information /J Ap //.4 Date of Treatment P(LAIr4L 7-9� _ Chemical Used rag Concentration , YT Gallons Used Method of Appligationl(soil mixed, etc.) Linear Footage of Area Treated Second Treatment Information Date of Treatment Chemical Used Concentration Gallons Used Method of Application (soil mixed, etc.) Linear Footage of Area Treated Please Note: The City of Port St. Lucie does not guarantee or warranty the preconstruiction soil treatment attested to in the above. The purpose of this document is to show that -.'.to the best of this department's knowledge, the builder has satisfied the requirements of the Florida Building Code for protection against termites. This form to the Building Department before your final inspection is scheduled! OFFICE USE ONLY: DATE FILED: l l i3 REVISION FEE: 2. DETAILED DESCRIPTION OF PROJECT REVISIONS: 3. 4, PERMIT # 1211 #65- RECEIPT # Oro CONTRACTOR INFORMATION:, STATE of FL REG./CERT. #: ST. LUCIE COUNTY CERT. #: BUSINESS NAME: QUALIFIERS NAME: ADDRESS: CITY: STATE: PHONE (DAYTIME): FAX: OWNER/BUILDER��ATION:- NAME: ADDRESS: CITY: GG STATE: _ PHONE: 0 f — r%i / ef� R_L 5. ARCHITECT/ENGINN NAME: c/ ADDRESS: CITY: PHONE (DAYTIME): SLCCC: 9/23/09 Revised 04/26/2010 INFO T N: STATE: 1"4 :4A ZIP: ZIP: ZIP: j FAX: —1W - C J LS ]ENGINEERING CONSULTANTS, ]L]LC CONSULTING ENGINEERS . � i4�•1'� dui �� ! January 16, 2013 St. Lucie County Building and Inspections 2300 Virginia Ave. Fort Pierce, FL 34982 Re: Roof Dry -in Material Britton Residence 5812 Spring Lake Terrace Fort Pierce, FL 34951 Permit #1211-0085 To Whom It May Concern: This letter is written to provide certification that I, as a Professional Engineer, have been retained to establish compliance with the St. Lucie County codes and regulations pertaining to the roof dry -in at the residence listed above. The roof underlayment system may be a "cold process application' of 90# felt over a 30# felt base sheet, or peel-n-stick may be used in place of the hot -mopped system that was specified in the permitted plans and specifications. The roof product to be used is as follows: Manufacturer: "Bntegra Roof Tile, Inc." Product: Estate "S" TAS 112, Type 1B, interlocking, low -profile, concrete roof tiles Florida Product Approval: FL7804 The engineering services addressed therein have been performed and based upon my professional engineering knowledge, technical documentation, information and belief, and in accordance with commonly accepted procedures consistent with applicable standards of practice, and is not a guaranty or warranty, either expressed or implied. Should you have any questions, please feel free to call me at (772) 473-2571. EN Jason W. Shortg M.ASCE Clc. w Wobert Britton /I- o6fr ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR C014EP I NCE REVIEWED BY DATE PLANS AND PERMIT MUST BE KEPT ON J013 OR NO INSPECTION WILL BE MADE EXTERIOR RESEARCH & DESIGN, LLC. M Certificate of Authorization #9503 TD �R �� ( 353 CHRISTIAN STREET, UNIT *13 R [� ( ERD OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 EVALUATION REPORT Entegra Roof Tile, Inc. Evaluation Report E39310.11.11-1-Ri 1289 NE 9at Avenue FL7804-R7 Okeechobee, FL 34972 Date of Issuance: 11/02/2011 Revision 1: 06/22/2012 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2010 Florida Building Code (HVHZ) sections noted herein. DESCRIPTION: Entegra Concrete Roof Tiles (HVHZ jurisdictions) LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinitylERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then It shall be done In its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for Inspection at the job site at the request of the Building Official. ' This Evaluation Report consists of pages 1 through 7. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANSI 983 The facsimile seal appearing was authorized by Robert Nleminen, P.E. on 06/22/2012 This does not serve as an electronically signed document. Signed, sealed hardcoples have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does It Intend to acquire or will it acquire, a financial Interest in any company manufacturing or distributing products It evaluates. 2. TrinitylERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial Interest In any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nleminen, P.E. does not have, nor will acquire, a financial Interest In any other entity Involved In the approval process of the product. 'j'�JNINIERD ROOFING SYSTEM EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Roofing Tiles Compliance Statement: Entegra Concrete Roof Tiles, as produced by Entegra Roof Tile, Inc., have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: $ Section6 Standard �Properties Year 2200 1525 2 Physical TAS 112 1995 2007 1523.6.5.2 Wind Driven Rain TAS 100 1995 2007 1523.6.5.2.2 Static Uplift Resistance TAS 101 1995 2007 1523.6.5.2.3 Static Uplift Resistance TAS 102 1995 2007 1523.6.5.2.3 Static Uplift Resistance TAS 102(A) 1995 2010 1523.6.5.2 Physical Properties TAS 112 2011 2010 1523.6.5.2 Wind Driven Rain TAS 100 2011 2010 1523.6.5.2.2 Static Uplift Resistance TAS 101 2011 2010 1523.6.5.2.3 Static Uplift Resistance TAS 102 2011 2010 1523.6.5.2.3 Static Uplift Resistance TAS 102(A) 2011 3. REFERENCES: Entoly Examination Reference Date ATL(TST3782) TAS 112 RT0615.01-11 06/28/2011 ATL(TST3782) TAS 112 RT0615.02-11 06/28/2011 ATL(TST3782) TAS 112 RT0615.03-11 06/28/2011 ATL(TST3782) TAS 112 RT0615.04-11 06/28/2011 ATL(TST3782) TAS 112 RT0615.05-11 06/28/2011 Tile Roof Institute TAS 100, TAS 101, 102, 102(A) Membership Confirmation Current PRI (QUA9110) Quality Assurance Service Confirmation 11/02/2011 4. PRODUCT DESCRIPTION: 4.1 BERMuDA Fur and PLAwTATzom Farr are TAS 112, Exterior Research and Design, LLC. CerWkate of AuthorizaMn #9503 Type 3a (flat -profile) concrete ooF i = p Evaluation Report E39310.11.11-1-Ri FL7804-R7 Revision 1: 06/22/2012 Page 2 of 7 4.2 4.3 4.3 �T'RINI`jYlERD ESTATE "S" are TAS 112, Type 1b (interlocking, low -profile) concrete roof tiles. BELLA HIGH "S" are TAS 112, Type 1a (interlocking, high -profile) concrete roof tiles. GALENA SPANIsH "S" are TAS 112, Type 2a (non -interlocking, high -profile) concrete roof tiles. 17" 70� 5. LIMITATIONS: 5.1 This Evaluation Report Is for use in FBC HVHZ jurisdictions or other jurisdictions adopting FBC HVHZ requirements. 5.2 Fire classification is not part of this evaluation; refer to FBC Section 1516 or current Approved Roofing Materials Directory for fire rating of this product. 5.3 Reference is made to FBC Section 1512.4.2.4 regarding field testing of completed tile. roof installations. 5.4 Applicant shall retain the services of an FBC listed, accredited laboratory to perform quarterly tests in accordance with TAS 112, Appendix W. Such testing shall be submitted to TrinitVJERD for review. Exterior Research and Design, LLC. Evaluation Report E39310.11.11-1-Ri CertMcate ofAuthorizatton A9503 FL7804-R7 Revision 1: 06/22/2012 Page 3 of 7 TRINYTYIERD 5.5 Minimum underlayment shall comply with the RAS 118, RAS 119 or RAS 120, as applicable. Underlayment products shall hold Florida Statewide Product Approval or Local Approval for use in tile roof assemblies in HVHZ jurisdictions. 5.6 Minimum roof deck requirements shall be in accordance with applicable FBC HVHZ requirements. 5.8 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C. Rule 9N-3. 6. INSTALLATION: 6.1 Entegra Concrete Roof Tiles may be mechanically fastened, mortar -set or adhesive -set. Installation shall comply with manufacturer's current published instructions, but not less than the requirements of RAS 118, RAS 119 or RAS 120, as applicable. 6.2 Attachment Calculations: Entegra Concrete Roof Tile shall be evaluated as a 'Moment -Based System' in accordance with RAS 127-95 (for 2007 Code) or RAS 127-11 (for 2010 Code) using the data outlined herein. Table 1: Aerodynamic Multipliers Tile Batten Application Direct -Deck Application Bermuda Flat 0.189 0.205 Plantation Flat 0.267 0.289 Bella High "S" 0.349 0.378 Estate "5" 0.267 0.289 Galena Spanish "S" N/A 0.235 Table 2: Restoring Moment due to Gravity - Ma (ft-lbf) Tile Roof Slope 10) 2:121043:12 3:12_0<4:12 M1216<St12 5:1210<6:12 6:22<A<7:12 817:12 Batters Dlreot Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Bermuda Flat 5.22 6.43 5.17 6.37 5.09 6.27 4.98 6.15 4.86 6.00 4.72 5.83 Plantation Flat 7.22 7.91 6.85 7.79 6.75 7.67 6.61 7.52 6.44 7.32 6.26 7.04 Bella High "5" 6.19 6.89 6.11 6.80 5.99 6.67 5.85 6.51 5.68 6.33 5.50 6.13 Estate "S" 6.14 5.34 5.91 1 6.74 5.82 6.64 5.70 6.50 5.56 16.33 5.40 6.14 Galena Spanish "5" N/A 6.20 N/A 1 6.13 1 N/A r 6.03 NIA 1 5.89 N/A 5.74 N/A 5.57 Exterior Research and Design, LLC. Evaluation Report E39310.11.11-1-Ri Cert1/lcate of Authorization *9503 FL7804-R7 Revision 1: 06/22/2012 Page 4 of 7 �J' '�'{��NIERD Table 3A-1: Attachment Resistance Expressed as a Moment - Mf (ft-ibf) Flat Profile Tiles, Mechankally Attached Systems Tile Fastener Direct -Deck n. (mPlly"") Direct -Deck ( PIS). eattem Type # She Shards alp Bermuda Flat or Plantation Nall One (1) 10d Smooth or Screw N/A 7.3 9.8 4.9 Nail Two (2) 10d Smooth or Screw N/A 14.0 18.8 7.4 Nail One (1) 10d Smooth or Screw Eave 19.0 19.0 22.1 Nail one(1) 10d Smooth or Screw Field 24.3 24.3 24.2 Nall Two (2) 10d Smooth or Screw Eave 31.9 31.9 32.2 Nail Two (2) 10d Smooth or Screw Field 35.5 35.5 EX8Flat Nail Nail' Two (2) Two (2)' 10d 10d' Ring Ring' N/A N/A 30.9 50.3 38.1 65.5 2 48.3' Screw One (1) #8 N/A N/A 30.8 30.8 18.2 Screw Two (2) #8 N/A N/A 51.7 51.7 24.4 ' Installation with a flinch the headlap and fasteners located min. 234-inch from head of tile. Table 3A-2: Attachment Resistance Expressed as a Moment- Mf (ft-1110 Flat Profile Tiles, Adhesive -Set Systems Site (Ini++) weight (9) To Substrate To Tile TO Substrate To Tile Tile Application Adhesive Mf (ft-lbf) TILE BOND- 1 X 6 1 X 6 10.4 10.4 40.6 Touch'n Seal'" 1.25 x 10 1.25 x 8 8.3 10.2 73.2 StormBond 3M Foam Hoof Tile Adhesive KrA-1(formedy 4 x 8 4 x 8 12 12 51.8 Bermuda Flat Inter- Dependent or Plantation Polyset• One) 3M 2-0mponent Foam Roof Tile Adhesive AH-160 4 x 4 2 x 4 16 8 31.3 Flat (formerly PoIMOI AH160) 3M 2-component Foam 2 x 7 N/A 24 N/A 40.4 �10 N/A 45 N/A 118.9 Independent Roof Tile Adhesive AN-160 (formerly PolyPro AH160) Exterior Research and D"19n, LLC- CerWicate ofAuthodkoffon *9503 {J V. a i E aluatlon Report E39310.11.11-i-Ri �� FL7804-R7 i'I Revision 1: 06/22/2012 i p ? Page 5 of 7 Table 36-2: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) Low Profile Tiles, Mortar & Adhesive -Set Systems Size (inch) Weight (g) To Substrate To Tile To Substrate To Tile Tile Application Adhesive Mf (ftdbf) TILE BOND"' 1 x 6 1 x 6 20.4 20.4 43.8 Touch'n Seal" StormBond 1.25 x 10 0.75 x 10 8.4 5.1 41.8 3M Foam RoofMIe Adhesive RTA-1(formerly Polyset* One) 4 x 8 4 x 8 12 12 44.0 Inter- Dependent 3M 2-Component Foam Roof Tile Adhesive AN-160 4 x 4 2 x 4 16 8 31.3 Estate'T (formerly PolyPro" AH160) 3M 2-Component Foam 2 x 7 N/A 24 N/A 45.5 2x10 N/A 54 N/A 86.6 Independent Roof TileAdhesiv:AH-160 (formerly PolyPro AH160) Mortar Per RAS 120 and Product Approval of Mortar Mfgr 1 20.6 Table 3C-1: Attachment Resistance Expressed as a Moment - Mf (ft4bf) High Profile Tiles, Mechanically Attached Systems Tile Fastener Direct - (min. 15/32" aymod) Direct Deck (min.19/32" plVWpd) Battens Type # Size Shank dip Bella High "5" or Galena Spanish "S" Nall One (1) 10d Smooth or Screw N/A 5.1 6.8 2.8 Nall Two (2) 10d Smooth or Screw N/A 6.9 9.2 7.3 Nall One (1) 10d Smooth or Screw Field 23.1 29.1 19.0 Nail One (1) 10d Smooth or Screw Eave 29.3 29.3 24.0 Nail Two (2) 10d Smooth or Screw Field 27.6 27.6 38.6 Nail Two (2) 10d Smooth or Screw Eave 38.1 38.1 41.8 Nail Nail' Two (2) Two (2)' 10d 10d' Ring Ring' N/A N/A 28.6 33.1' 41.2 48.1' 19.4 S0.9' Screw One (1) #8 N/A N/A 20.7 20.7 18.1 . Screw Two (2) #8 N/A N/A 43.2 43.2 29.8 ' Installation with a 4-inch tile headiap and fasteners located min. 2Yrinch from head of tile. Table 3C-2: Attachment Resistance Expressed as a Moment- Mf (falbf) High Profile Tks, Mortar & Adhesive -Set Systems Size (inch) Weight (9) To Substrate 1 x 6 To Tile 1 x 6 To Substrate 10.4 To Tile 10.4 Tile Application Adhesive TILE BOND- Mf ift-Ibf) 48.1 Touch'n Seal- StormBond 1.25 x 10 0.75 x 8 8.4 3.9 S1.6 3M Foam Roof Tile Adhesive 11TA-1(formerly Polyset• One) 4 x 8 4 x 8 12 12 36.2 Bella High "S" Inter. Dependent 3M 2-Component Foam Roof Tile Adhesive AN-160 (formerly PolyPro® AH160) 4 x 4 2 x 4 16 8 35.3 or Galena Spanish "S" 3M 2-Component Foam 20 7 N/A 24 N/A 38.7 2 x 10 N/A 63 NIA 5 independent Roof Tile Adhesive AH-160 (formerly PolyPro® AH160) Mortar J Per RAS 120 and Product Approval of Mortar Mfgr 24.5 Exterior Research and Design, LLC. 1 Evaluation Report E39310.11.11-1-Ri �4 •:) V ' � �,:j `,,� FL7804-R7 certlncel* oiAathorhadon #9503 1 S Revision 1: 06/22/2012 Page 6 of 7 TPJNITYIERD' 7. LABELING: 7.1 Each unit shall bear the imprint or Identifiable marking of the manufacturer's name or logo, as detailed below. Tile lots shall be labeled in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. � ENTC�GRG°� � e. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the Installation of this product. 9. MANUFACTURING PLANTS: Okeechobee, FL 10. QUALITY ASSURANCE ENTITY: PRI Construction Materials Technologies, LLC. - QUA9110; (813) 621-5777 - END OF EVALUATION REPORT - 711 Exterior Research and Design, LLC. Evaluation Report E39310.11.11-1-Ri CertNlcate o/Audiorisatlon 09503 FL7804-R7 Revision 1: 06/22/2012 Page 7 of 7 Lumber design values are in accordance with ANSI/TPI 1-2007 section 6.3 These truss designs rely on lumber values established by others. MiTek � RE: 24208 - MiTek USA, Inc. Site Information: 6904 Parke East Blvd. Customer Info: Robert Britton Project Name: Britton Residence Model: Addition Tampa, FL 33610 4115 Lot/Block: Subdivision: Portofino Shores Address: 5812 Spring Lake City: Ft. Pierce / St Lucie State: FI Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: State: General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2010/TP12007 Design Program: MiTek 20/20 7.3 Wind Code: ASCE 7-10 Wind Speed: 170 mph Floor Load: N/A psf Roof Load: 55.0 psf This package includes 2 individual, dated Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. No. 1SeaI# ITruss Name Date 1 IT4602760 IA01 11/6/012 12 I T4602761 I A02 11 /6/012 The truss drawing(s) referenced above have been prepared by MiTek Industries, Inc. under my direct supervision based on the parameters provided by East Coast Truss. Truss Design Engineer's Name: Magid, Michael My license renewal date for the state of Florida is February 28, 2013. NOTE: The seal on these drawings indicate acceptance of professional engineering responsibility solely for the truss components shown. The suitability and use of this component for any particular building is the responsibility of the building designer, per ANSI/TPI-1 Sec. 2. kEV. � �v �ZS Fc- ,,,� FL Cert. 6634 November 6,2012 Magid, Michael 1 of 1 Job Truss Truss Type Oty Ply T4602760 24208 A01 COMMON TRUSS 1 1 Job Reference (optional) East Coast Truss, Fort Pierce, FL 34946 7.350 s Sep 26 2012 MTek Industries, Inc. Tue Nov 0614:44.22 2012 Page ID:W9DCfFBnTSR5y??BNIoZRyLuUD-bPdENcC84la94NIaWPbd6gOPAn?V 3Nzo?hAwyLu 1 1 9-10 9-8-0 1 Scale: 3W=l' 4x4 = 5 r�4 1x4 I I 1x4 5.00 12 4 6 - 1x4 11 1x4 11 3 7 1x4 II 1x4 II 2 8 1 9 0 11 I$ 3x4 = 3x4 = 16 15 14 13 12 11 10 1x4 II 1x4 I I 1x4 II 5x5 = 1x4 II 1x4 II 1.4 II . 1-0-0 19-0A 1-0.0 18.4-0 Plate Offsets X 13:0-2-8 0-3-0 LOADING (pso SPACING 2-0-0 CS1 DEFL in (loc) I/defl L/d PLATES GRIP TCLL 30.0 Plates Increase 1.33 TC 0.44 Vert(LL) n/a - n/a 999 MT20 244/190 TCDL 15.0 Lumber Increase 1.33 BC 0.32 Vert(TL) n/a - n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.17 Horz(TL) -0.01 10 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix) Weight: 85 [b FT = 5% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 10.0-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. OTHERS 2x4 SP No.3 MTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer [installation guide. REACTIONS All bearings 17-4-0. (Ib) - Max Horz 16=98(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 14, 15, 16, 12, 11, 10 Max Grav All reactions 250 lb or less atjoint(s) 15, 11 except 13=479(LC 2), 14=297(LC 19), 16=590(LC 19). 12=297(LC 20), 10=590(LC 20) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-2=71/466, 2-3=4/401, 3-4=0/431, 4-5=0/417, 5-6=0/417, 6-7=0/431, 7-8=4/401, 8-9=71/466 BOT CHORD 1-16=359/84, 15-16=359/84, 14-15=359/84, 13.14=359/84, 12-13=359/84, 11 -1 2=359/84, 10-11=359/84, 9-10=359/84 WEBS 5-13=445/0, 2-16=-407/108, 8-10=-407/108 `I%J11111111i1I NOTES 1�� �� S. 1) Unbalanced roof live loads have been considered for this design. `��P 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.0psf; h=15ft; B�5ft; L=24ft; eave=2ft; Cat. Ili; Exp 0,.,• E �% G IN B; Encl., GCp[=0.18; MWFRS (directional); cantilever left and right exposed; end vertical left and right exposed; Lumber DOL=1.60 plate `��.�N�� gripDOL=1.60 No 53681 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gab[ End Details as applicable, or consult qualified building designer as per ANSI/TPI 1-2002. 4) Gable studs spaced at 2-0-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit . 3 STATE F . between the bottom chord and any other members. �. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 14, 15, 16. 12, 11, 10. 8 N/A 9) "Semi -rigid pltchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. ��j CSC ....... ��j S�� 10) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. P►L ``,fit �1111111111o� LOAD CASE(S) Standard FL Cert. 6634 November 6,2012 AWdRNING - Verffy design pm+mrlet" andREdD N0773S ON 7WS AM INCMfIOED X=RBFB UMB PAGE jet-7473 BEFORE USIR ■� Design valid for use only with MTek connectors. This design's based only upon parameters shown, and Is foran Individual building component. AppltcabTty of design parameters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsiblfity of the MiTek' erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/fPll Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610-4115 N Southem Pine ISP or SPp) lumber is specified the design values are those effective 86101t20112 by ALSC or proposed by SPIIL Job Truss Truss Type Qty Ply T4602761 24208 A02 COMMON TRUSS 4 1 Job Reference (Optional) East Coast Truss, Fort Pierce, FL 34946 7.350 s Sep 26 2012 MTek Industries, Inc. Tue Nov 0614:44:24 2012 Page ID:W9DCfFBnTSR5y??BNIoZRyLuUD Yol?oHEOcMgtJhvzdgvPkxwlazNnztzgQ6UoEpyLu5 a 1 a 1 1-4-0 5-1-3 3-2-13 3-2-13 5-1-3 Scale = 1:32.4. G �n 5.00 12 1x4 1x4 �i �1 i 3 5 1x4 II W II 2 6 1 7 � I$ 9 3x4 = 10 Sx8 — — 8 W 11 3x4 = 1x4 II 1-40 1 9.8.0 18-0-0 1 1s-4-o 1-a0 0-4- B-4-0 B-4-0 1-a0 Plate Offsets X 2:0-2-7 0-0-5 6:az-7 0-0-8 8:0-2-3 0-0-E 9:04-o 0-3-0 10:0-2-3 O-0-B LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Well Ud PLATES GRIP TCLL 30.0 Plates Increase 1.33 TC 0.65 Vert(LL) -0.09 9 >999 240 MT20 244/190 TCDL 15.0 Lumber Increase 1.33 BC 0.68 Vert(TL) -0.21 9.10 >947 180 BCLL 0.0 Rep Stress Incr YES WB 0.21 Horz(TL) 0.04 8 Na Na BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight: 79 lb FT = 5% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or4-0-10 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x4 SP No.3 MTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 10=91810-8-0 (min. 0-1-8), 8=918/0-8-0 (min. 0-1-8) Max Horz 10=98(LC 6) Max Uplift 10=204(LC 8), 8=164(1_C 8) Max Grav, 10=1063(LC 2), 8=1063(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-2=1233/628, 2-3=1503/267, 3-4=1165/228, 4-5=1165/229, 5-6=1503/268, 6-7=1233/628 BOT CHORD 1-10=861/1289, 9-10=161/1289, 8-9=163/1289, 7-8=861/1289 WEBS 4-9=101/554, 5.9=371/130, 3-9=371/127, 2-10=758/256, 6-8=758/237 NOTES 1) Unbalanced roof live loads have been considered for this design. ♦♦%Jl111l�l1111 2) Wind: ASCE 7-10; Vu@=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft: eave=oft; Cat. Ili; Exp 0% Q `S; ��j�� B; Encl., GCpt=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate ,♦♦•�`' • �M� DOL=1.60 Cj`,E N grip �� .G 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. `��.��� '�� SF�'••��`-�i� 4) • This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit : N O 53681 1 between the bottom chord and any other members. * 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8=164.6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this except Qt=lb) 10=204, �• truss.7) ?:Z44 Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.STATE FLOAD CASE(S) Standard4O\ • s .� .•' C!' �% S/O N AL ��♦1, lll111111 FL Cert. 6634 November 6,2012 ® WARMNG -Vcnjy design pwwnde,a and MD MnM ON 7WS AND INCLimED J97EKRBFBRWB PAGE M-7473 BBFORB US& Design valid for use onlywith MuTek connectors. This design is based only upon parameters shown, and B for on Individual building component. Applicability of design parameters and proper Incorporation of component Is responsibility of building designer- not truss designer. Bracing shown Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the MiTek• erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/rPll Quality Criteria, DSB-89 and BCSI Building Component 69D4 Parke East Blvd. Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610-4115 If Southern Pine (SPorS lumber is specified, the design values are those effective W8/f2D12byALSCorproposed by SPIIL Symbols PLATE LOCATION AND ORIENTATION 3/4 Center plate on joint unless x, y offsets are indicated. Dimensions are in ft4n-sixteenths. Apply plates to both sides of truss and fully embed teeth. 0 'T/16 5-; -- 2 For 4 x 2 orientation, locate plates 0-'Al' from outside�-- edge of truss. This symbol indicates the _ required direction of slots in-, connector plates. I n Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the plate 4 x 4 `Width measured perpendicular to slots. Second dimension is the length parallel to slots. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths (Drawings not to scale) 1 2 3 TOP CHORDS ct-2 c2a WEBS c� 4 o 0 u 3 3 U t' O �'� U o- O o- ~ c7-8 c6-7 cs-6 00 BOTTOM CHORDS JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. PRODUCT CODE APPROVALS ICC-ES Reports: ESR-1311, ESR-1352, ESR1988 ER-3907, ESR-2362, ESR-1397, ESR-3282 LATERAL BRACING LOCATION Southern Pine lumber designations are as follows: Indicated b symbol shown and/or y y SYP represents current/old values as published by AWC in the 2005/2012 NDS by text in the bracing section of the SPp represents SPIB proposed values as provided output. Use T or I bracing in SPIB submittal to ALSC dated Sept 15, 2011 if indicated. SP represents ALSC approved/new values with effective date of June 1, 2012 BEARING (2x4 No 2 and lower grades and smaller sizes), and all MSR/MEL grades Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Min size shown is for crushing only. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate ,Connected Wood Trusses. © 2012 MiTek® All Rights Reserved mm 181 MiTek° MTek Engineering Reference Sheet: Mll-7473 rev. 09/04/2012 General Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI. 2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered. 3. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1. 7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1. 8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber. 10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements. 12. Lumber used shall be of the species and size, and In all respects, equal to or better than that specified. 13. Top chords must be sheathed or purlins provided at spacing indicated on design. 14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling Is installed, unless otherwise noted. 15. Connections not shown are the responsibility of others. 16. Do not cut or alter truss member or plate without prior approval of an engineer. 17. Install and load vertically unless indicated otherwise. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. 19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient. 20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria. COUNTY BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE MIAMI-DADE COUNTY, FLORIDA METRO-DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130-1563 (305) 375-2901 FAX (305) 375-2908 Hanson Roof Tile 1340 SW 34th Ave r a' Deerfield Beach, FL 33442 SCOPE: a'v This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control, Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Hanson Hacienda Double Roll Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA No. 07-0914.06 and consists of pages 1 through 5. The submitted documentation was reviewed by Alex Tigera. NOA No.: 09-0928.03 CfN41AMM1-DADMEC0=U Expiration Date: 12/16/12 Approval Date. 11/18/09 Page I of 5 ROOFING ASSEMBLY APPROVAL Category: Roofing , Sub Category: Roofing Tile Material: Concrete 1. SCOPE This approves a roofing system using Hanson Hacienda Roof Tile,. as manufactured by Hanson Roof Tile in Hobe Sound, Florida and as described in Section 2 of this Notice of Acceptance. For the locations where the pressure requirements, do not exceed the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Test Product Applicant Dimensions Specifications Description Length: 17'/" Low profile, interlocking, extruded concrete Hanson "Hacienda" Width: 13" TAS 112 roof tile equipped with two nail hole and ''/z" thick double roll ribs. For direct deck or battened nail -on, mortar or adhesive set applications. Length: varies Accessory trim, concrete roof pieces for use Trim Pieces Width: varies TAS 112 at hips, rakes, ridges and valley terminations. Varying thickness Manufactured for each tile profile. 2.1 EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Report Date American Test Lab of RT0922.02-09 TAS 102 09/22/09 South Florida PRI Construction HRT-054-02-02 TAS 101 09/18/09 Materials Technologies PRI Construction HRT-054-02-01 TAS 101 09/22/09 Materials Technologies IBA Consultants, Inc. 2381-249 TAS 112 09/20/07 NOA No.: 09-0928.03 MIAMI•DADE COUNTY Expiration Date: 12/16/12 Approval Date: 11/18/09 Page 2 of 5 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with RAS 106 may be required, refer to applicable building code. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications_ Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 4. INSTALLATION 4.1 Hanson.`Hacienda' Roof Tile and its components shall be installed. in strict compliance with Roofing Application Standard RAS 118, 119, & 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight-W (lbf) Length -I (ft) Width-w (ft) Hanson Hacienda . 10.0 1.4375 1.08 Table 2: Aerodynamic Multipliers - ft Tile Profile '% (ft) Batten Application X (ft) Direct Deck Application Hanson Hacienda N/A 0.32 ti Table 3: Restoring Moments due to Gravi - M ft-lb Tile Profile 2":12" 3":12" 4":12" 5":12" VAT' 7":12" or reater Hanson Hacienda Direct Deck Direct Deck Direct Deck Direct Deck Direct Deck Direct Deck 7.37 1 7.29 7.17 7.02 6.84 6.64 NOA No.: 09-0928.03 MIAMI•DADECOUIN Y Expiration Date: 12/16/12 • . ' Approval Date: 11/18/09 Page 3 of 5 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) For Nail -On Srstemsct Fastener Type Deck 15/32" Direct DeckTile (min. 19/32" Battens Profile woodplywood)HansonHacienda Two 2 . # 8 x 3" Screws35.9 35.9 N/A Table 5: Attachment Resistance Expressed as a Moment - Mf (ft-ibf) For Two Patty Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Hanson Hacienda Tile Bond Resistance 44.4 1 Dow Chemical Tile Bond Tm. Two Patty's of 11 q were installed as per Tile Bond NOA. Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) For Single Patty Adhesive Set Systems— Tile Tile Application Minimum Attachment Profile Hanson Hacienda Polyfoam PolyProTm Resistance 29.2 Polyfoam PolyProT'" 39.0 2 Medium paddy placement of 24 rams of Pol ProTm AH-160. 3 Larne paddy placement of 54 rams of Pol ProT"' AH-160. 5. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo (See Detail Below), or following statement: "Miami -Dade County Product Control Approved". Hanson HANSON HACIENDA ROOF TILE TILE IDENTIFICATION MARK (LOCATED ON UNDERSIDE OF TILE 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 09-0928.03 rw►ratieaoecourfrr Expiration Date: 12/16/12 APPROYED Approval Date: 11/18/09 Page 4 of 5 PROFILE DRAWINGS HANSON HACIENDA CONCRETE ROOF TILE FASTED END OF THIS ACCEPTANCE BLOCK NOA No.: 09-0928.03 Expiration Date: 12/16/12 hnaMMADE000NW Approval Date: 11/18/09 Page 5 of 5 FORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: BRIT Builder Name: Permit Office: 3 `' Street: City, State, Zip: ST. LUCIE COUNTY, FL, Owner: Permit Number: Jurisdiction: f'• r :^ ' Design Location: FL, Fort Pierce 1. New construction or existing New (From Plans) 9. Wall Types (700.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 700.00 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 0 d. N/A R= ft2 10. Ceiling Types (306.0 sqft.) Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=19.0 306.00 ft 6. Conditioned floor area above grade (ft2) 306 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A 11. Ducts R= ft2 R ft2 7. Windows(57.0 sqft.) Description Area a. U-Factor: Sgl, U=0.70 57.00 ft2 SHGC: SHGC=0.43 b. U-Factor: NIA ft2 12. Cooling systems kBtu/hr Efficiency a. Central Unit 9.0 SEER:16.00 SHGC: c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtulhr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 6.4 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.430 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (306.0 sqft.) Insulation Area EF: 0.920 a. Slab -On -Grade Edge Insulation R=0.0 306.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Total Proposed Modified Loads: 9.98 Area: 0.186 ���� Glass/Floor Total Standard Reference Loads: 13.46 I hereby certify that the plans and specifications cover d this calculation are in compliance with the Florida En g /f Review of the plans and specifications covered by this THE S74 F0 Code. L(2) -t,1 calculation indicates compliance630 �C "A with the Florida Energy Code. Before construction Is completed �'r:;, •-; - = ' °;,," „ PREPAR BY: e2 _ _ __ _ DATE: ---c�Q_�--o_-.----- ---- - ------ this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Code. Florida Statutes. OD with the Florida Energy WE OWNER/AGENT: __ _ _. _ BUILDING OFFICIAL: DATE: - . - _ DATE: - - - -- - - - - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist 12/10/2012 10:03 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5 PROJECT Title: BRIT Bedrooms: 0 Address Type: Street Address Building Type: FLProp2010 Conditioned Area: 306 Lot # Owner. Total Stories: 1 Bk6dSubDivision: # bf Units: 1 Worst Case: Yes PlatBook: Budder Name: Rotate Angle: 225 Street: permit Office: Cross Ventilation: County: ST. LUCIE Jurisdiction: Whole House Fan: City, State, Zip: ST. LUCIE COUNTY, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp J Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL ST_LUCIE_CO INTL 2 39 90 70 75 M 62 Low BLOCKS Number Name Area Volume 1 Blockl 306 3060 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 RoomsinBloekl 306 3060 Yes 0 0 1 Yes Yes Yes FLOORS Floor Type Space _ _ Perimeter R-Value Area Tile Wood Carpet lab-On-Grade Edge Insulatio RoomelnBtockl 70 It 0 psv 306 Its _.,. 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch Type Materials Area Area Color Absor. Tested Tested Insui. (deg) ) 1 Hip Barrel the 3314-1 0 tt= Medium 0.96 No 0.9 No 0 22.6 ATTIC s Type Ventilation Vent Ratio (1 In) Area Ras IRCC 1 Full attic Vented 300 306 fe N N CEILING # Ceiling Type Space ;Value Area Framing Frac Truss Type 1 Under Attic (Vented) RoamslnBkw*l 19 306 W 0.11 Wood 12/1012012 10:03 AM EnergyGaugeO USA - FlaRes2010 Section 405A.1 Compliant Software Page 2 of 5 WALLS / Adjacent Cavity Widih Height Sheathing Framing Solar Below V # Omt S To . Well Type . PA R-Value Ft In Ft la-. _._.... Area. ,... R-Value . Fraction Absor. Grade% _ 1 N Exterior Concrete Block - Int InsWoomsln5loc 4.1 17 10 170 ft2 4.1 0 0.75 0 2 S Exterior Concrete Block - Int Insfitoomsin8loc 4.1 17 10 170 ft2 4.1 0 0.75 0 _ 3 E Exterior Concrete Block - Int tnsaoomsln8loc 4.1 18 10 180 ft2 4.1 0 0.76 0 4 W Exterior Concrete Block - Int Insl#oorrislnBloc 4.1 18 10 180 ft2 4.1 0 0.75 0 DOORS # Omt Door Type Space Storms U-Value Ft Width In FHeight Area 1 W Insulated RoomslnBloc ' Metal 0A60000 3 7 21 W WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall Overhang v ry Omt ID Frame Panes NFRC U-Factor SHGC Storms Area Depth Separation Int Shade Screening 1 N 1 Metal Single (Clear) Yes 0.7 0.43 N 45 W 2 ft 0 in 0 ft 0 in HERS 2006 None 2 E 3 Metal Single (Clear) Yes 0.7 0.43 N 12 ft2 2 ft 0 in 0 ft 0 in HERS 2006 None INFILTRATION # Scope Method SIA CFM 50 ElA EgIA ACH ACH 50 t BySpaces Proposed SLA 0.000360 288.95 16.863 29.832 0.2628 5.6657 HEATING SYSTEM # System Type, Subtype Efficiency Capacity Block Duds 1 Electric Strip Heat None COP: 1 6.4 kStu/hr 1 Ductless COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow 5HR Block Ducts 1 Central Unit None SEER: 16 9 kBtu/hr 270 kdm 0.75 1 Ductless HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Interior o.92 40 gal 30 gal 120 dog None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None Rz 12/101201210:03 AM EnergyGaugeO USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6 TEMPERATURES Programab eX Thermostat�tXX:�jY Ceiling Fans: Lx1 Jan Lx] Feb C�XXjj Lxl Mar ��XXjj CxlA MMY a NJu Jun Jul Aug A g go Sep SOP CX�1 91 � (X�j Nov Nov fx) Dec KI Venting Venting [[�Xlj Jan [[�X1j Feb t(�x11 Mar, tt�xll X fxi Dec Thermostat Schedule: HERS 20M Reference Hours Schedule Type 1 2 3 4 5 6 7 a 9 10 11 12 Cooling (WD) AM PM 78 80 78 8o 78 76 78 78 78 78 78 78 78 78 78 76 80 78 Bo 78 80 78 60 78 Cooling (WEH) PM 78 78 78 78 78 78 78 78 76 78 78 78 Heating ) PM 8 68 68 68 68 68 68 68 68 66 66 Heating (WEH) PPMM 8 68 68 68 68 68 �6688 68 68 68 8 6666 66 12110=2 10:03 AM ErwrgyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Sollware Page 4 of 5 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: PERMIT* ST. LUCIE COUNTY, FL, ti MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full COMPONENT = SECTION SUMMARY OF REQUIREMENT(S) Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cf Wsq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope ' leakage report or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shalt be provided for each separate heating and cooling oling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 Ail ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 accessible manual OFF switch. Mechanical _+ 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shah not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat toss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating ' 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. Cellings/knee walls 405.2.1 R-19 space permitting. ,17 121101201210'03 AM EnergyGauge® USA - FlaRas2010 section 405.4.1 Compliant Software Page 5 Of 5 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 74 The lower the EnergyPerformance Index, the more efficient the home. , ST. LUCIE COUNTY, FL, 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 700.00 fl= b. N/A R= fN 3. Number of units, # multiple family 1 c. N/A R= ft: 4. Number of Bedrooms 0 d. N/A R= ft2 10. Ceiling Types insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=19.0 306.00 ft" 6. Conditioned floor area 00 306 b. N/A R= ft= c. NIA R= fe 7. Windows" Description Area 11. Ducts R ft a. U-Factor: Sgi, U=0.70 67.00 ft' SHGC: SHGC=0.43 b. U-Factor: N/A fe SHGC: 12. Cooling systems kBtuft Efficiency c. U-Factor: N/A fe a. Central Unit 9.0 SEER:16.00 SHGC: d. U-Factor. NIA fN 13. Heating systems kalu/hr Efficiency SHGC: a. Electric Strip Heat 6.4 COPA.00 Area Weighted Average Overhang Depth: 2.000 f . Area Weighted Average SHGC: 0.430 8. Floor Types insulation Area 14. Hot water systems Cap: 40 gallons a. Slab -On -Grade Edge Insulation R�.0 306.00 R' a. Electric EF: 0.92 b. N/A Rc ft' b. Conservation features c. NIA R` None 15. Credits t^j g! l ��IY', Pstat 1� I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: .Address of New Home: Date: City/FL Zip: cod ..,,d, n,. WE "Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. '"Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge® USA - FlaRes2010 Section 405.4A Compliant Software - - wrightsoft- Project Summary Entire House For: BRITT Notes: Project Information Design Information_ Weather: Fort Pierce, FL, US Winter Design Conditions Outside db Inside db Design TD Heating Summary Job: Date: Dec 10, 2012 By: f Summer Design Conditions 42 OF Outside db 70 OF Inside db 28 OF Design TD Daily range Relative humidity Moisture difference Structure 6888 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 6888 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 Heating Coolingg 306 Area (ftz) 306 Volume (ft') 3060 3060 Air changes/hour 0.61 0.32 Equiv. AVF (cfm) 31 16 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating Input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 80 AFUE 0 Btuh 0 Btuh � 31f 0.046 cfm/Btuh 0 in H2O 90 OF 75 OF 15 OF L 50 % 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 6987 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Blower 0 Btuh Use manufacturer's data n Ratelswing multiplier 0.95 Equipment sensible load 6637 Btuh Latent Cooling Equipment Load Sizing Structure 1082 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Equipment latent load 1082 Btuh Equipment total load 7719 Btuh Req. total capacity at 0.70 SHR 0.8 ton Cooling Equipment Summary Make Mitsubishi Electric Trade Cond MU-A09WA Coil MS-A09WA AHRI ref Efficiency 10.9 EER, 16 SEER Sensible cooling 6650 Btuh Latent cooling 2850 Btuh Total cooling 9500 Btuh Actual air flow 317 cfm Air flow factor 0.045 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.87 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. A+ wrightssoft" 2012-Dec-1009:58:39 ,.ter Right -Suite® Universal 2012 12.0.09 RSU12886 Page 1 �� C:%UserslOfflceDepotlDocumenlslWrightsoft HVAC%BRIT.rup Calc - M.18 Front Door faces: N - - wrightsoftr Load Short Form Entire House For: BRITT Job: Date: Dec 10, 2012 By: Htg Cig Infiltration Outside db (°F) 42 90 Method Simplified Inside db (°F) 70 75 Construction quality Average Design TD (OF) 28 15 Fireplaces 0 Daily range - L Inside humidity (%) 30 50 Moisture difference (gr/lb) 1 61 HEATING EQUIPMENT Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 80 AFUE 0 Btuh 0 Btuh 0 OF 317 cfm 0.052 cfm/Btuh 0 in H2O COOLING EQUIPMENT Make Mitsubishi Electric Trade Cond MU-A09WA Coil MS-A09WA AHRI ref Efficiency 10.9 EER, 16 SEER Sensible cooling 6650 Btuh Latent cooling 2850 Btuh Total cooling 9500 Btuh Actual air flow 317 cfm Air flow factor 0.057 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.84 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) ADDITION 306 6063 5551 317 317 Entire House 306 6063 5551 317 317 Other equip loads 0 0 Equip. @ 0.95 RSM 5274 Latent cooling 1082 -.•ems-.-w I - 1 no 1 nnBe 1 COGQ I 9.17 O47 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wri I7tS®, 2012-Dec-1010:01:06 g Rlght-SulteO Universal 2012 12.0.09 RSU12886 Page 1 BICCN C:IUsers%OfficeDepot%DocumentslWrightsoft HVACIBRIT.rup Cale = MJ8 Front Door faces: N -� - wrightsoft` Right-J® Worksheet Entire House Job: Date: Dec 10, 2012 By: 1 Room name Entire House ADDITION 2 Exposed wall 306.0 It 306.0 ft 3 Room height 10.0 I't 10.0 ft heal1cool 4 5 Room dimensions Room area 308.0 ft' 17.0 x 18.0 ft 306.0 fY Ty Construction U-value Or HTM Area (fly Load Area (ft� Load number (BtutVft? "F) (Btuh/ftj or perimeter (ft) (Btuh) or perimeter (ft) (Stuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 yJ 13A-4ocs 0.143 n 4.00 2.55 170 125 501 318 170 125 501 318 --G 1A-clom 1.270 n 35.56 34.77 45 0 1600 1565 45 0 1600 1585 W 13A-4ocs 0.143 a 4.00 2.55 180 168 673 428 180 168 673 428 r G 1 F-c3om 0.720 a 20.16 68.46 12 0 242 821 12 0 242 821 11 W 13A-4ocs 0.143 s 4.00 2.55 170 170 681 433 170 170 681 433 V�! T—D 13A-4ocs 0.143 w 4.00 2.55 180 159 637 405 180 159 637 405 11J0 0.600 w 16.80 17.40 21 21 353 385 21 21 353 365 C 1(3D-19td 0.049 1.37 1.59 306 306 420 487 306 306 420 487 F 22A-tpl 0.989 0.00 0.00 306 0 0 0 306 0 0 0 6 c) AED excursion 0 0 Envelope loss/gain 5105 4822 5105 4822 12 a) Infiltration 957 269 957 260 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants ® 230 2 460 2i 460 Appliances/other 0 0 Subtotal (lines 6 to 13) 6063 6551 6063 5551 Less external load o 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 6063 5551 6063 5551 15 Duct loads 0% 0% 0 0 -0% 09/0 0 0 Total room load 6063 5551 6063 1 5551 Air required (cfm) 317 317 317 317 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. - - wriigtttso€t' Right-Suile® Universal 2012 12.0.09 RSU12886 2012-Dec-10 OPage ; C:\Users\OtficeDepot\Documents\Wrightsofl HVAC\BRIT.rup Cale = MJ8 Front Door faces: N '.] — Planning & Development Services Department WHOMBuilding & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Designs Load Compliance Project Name: / x 1 eo ev"C>` sf6j Project Address: ��� Permit #: Occupancy Type: 12— 3 Construction Type: 001 INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving�the following: I —'j � � J ,. o New Residences (single or multi -family) i l� l o Residential Addition i j i f J o Any accessory structure requiring a building permit '? o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Code 2010 Edition with 20 Supplements using ASCE 7-10 2. Structure Designed as (check one): ✓/Enclosed Partially Enclosed —Open 3. Risk Category: _I ✓ II III IV Exposure Category: B �/C D 4. Design Wind Velocity �z� m mph r/ASD LRFD End Zone Width: �ft 6%!moo E/�(%ulr, 5. Mean Roof Height / Z ft Roof Pitch: s� :12 Parapet: ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): t/p. �/ t/F.9 t/�.9 �Zd•T V. T Zone 1: — 3o.f Zone 2: 5Z•5`- Zone 3: —77, P Zone 4: —Z9- / Zone 5: —26.9—Garage: A.0 7. Design Loads: Floor: 9O PSF Roof/Dead: PSF Roof/Live:-r 0 Balcony: PSF Dock:%rA PSF Deck: PSF Stairs: N/4--- PSF Fence: PSF Railings: L PSF 8. Were Shear Walls Considered For Structure? !�Yes Not Applicable Explain Why ot: 9. Is A Continuous Load Path Provided? es Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: ZOOO PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design ts le0VP1//i /Zip :ro . Igna ate, and $e,-Z O•� •. SATE OFAXORION • �/W` ''Sys/Al. vised 3/15/12 (JS) l/lllltI 10,E NIA-rex i-�r006-Rz Print Name Cert # & Co. Cart Auth. ,: ( {y-NC-1.7%e%rfi..G- _ p+ud'u.GT.�trsJ� LGc- Company Name & Address r M IAM I-#]►ADE MIAMI-DADE COUNTY 67AUUW PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY 11805 SW 26 Street, Room 208 AFFAIRS (PERA) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/pera/ 8130 NW 741h Avenue Medley, FL 33166 f [' =� 4 �l SCOPE: l ' -� •r This NOA is being issued under the applicable rules and regulations governing the useof cconstrue`tionl i materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series 112500" Aluminum Single Hung Window — L.M.I. APPROVAL DOCUMENT: Drawing No. W05-37, titled "Series 2500 Alum. Single Hung Window (L.M.I.)", sheets 1, 2, 2.1, 3,4 and 5 of 5, dated 07/26/05 with revision E dated 12/23/11, prepared by A]— Fatooq Corporation, signed and sealed by Javad Ahmad, P. E., bearing the Miami —Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, model/series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. • ADVERTISEMENT: The NOA number preceded by the words Miami -Dade. County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy-ofthis-entire NOA shall -be provided -to -the user by the manufacturer or itsg (distributors -and -shall -be va ail'abie-for inspection -at -the jobs te--at th ere quest-o h uildin OOffici This NOA revises NOA #-10=0428:02-and`consists-of--this-page ]--and-evidence-pages-E-l-and-E=2, as well as approval document mentioned above. The submitted documentation was reviewed by Manuel Perez, P.E. CN_0A,:NO _12-01.1.8A8 MIAMI•DAD; CO Expiration Date: December 01, 2015 Approval Date: March 15, 2012 Page 1 ` Trulite Window & Door Solutions, LLC NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Manufacturer's die drawings and sections. 2. Drawing No W05-37, Sheets 1, 2, 2.1, 3, 4 and 5 of 5, fitted Seri 2S ", lum, Single Hung Window (L.M.I.)", prepared by Al-Farooq Corporation, dated 07/26/05 with revision E dated 12/23/11, prepared by Al—Farooq Corporation, signed and sealed by Javad Ahmad, P. E. B. TESTS 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4rLage 1VSssile-Impact Test per FBC; TAS�21=94 ' 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411 3.2.1, TAS 202-94 along with marked —up drawings and installation diagram of aluminum single hung window, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-6088, dated December 02, 2009, signed and sealed by Michael R. Wenzel, P. E. (Submitted under NOA No.10-0428.02) 2. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201-94 2) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked —up drawings and installation diagram of aluminum single hung window, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-5250, dated July 30, 2007, signed and sealed by Carlos S. Rionda, P. E. (Submitted under NOA No. 09-0316.09) 3. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Forced Entry Test, per FBC 3603.2 (b) and TAS 202-94 along with marked —up drawings and installation diagram of aluminum single hung window, prepared by Hurricane Engineering & Testing Inc., Test Report No. HETI-04-1419A, dated Jan. 20, 2005, signed and sealed by Ivonne Ghia, P. E. (Submitted under NOA No. 05--0810.04) 4. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201-94 2) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked —up drawings and installation diagram of aluminum single hung window, prepared by Hurricane Engineering & Testing Inc., Test Report No. HETI44-1419B, dated Jan. 21, 2005, signed and sealed by Ivonne..Ghia, P. E. (Submitted under NOA No. 05-0810.04) Manuel Pe ez, .E. Product Control E(Undner NOA No.12-0118.18 Expiration Date: December 01, 2015 Approval Date: March 15, 2012 E-1 Trulite Window & Door Solutions, LLC NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC-200..1 and FBC-2010, prepared by Al-Farooq Corporation, dated 04/21/10 and updated on 01/04/12, signed and sealed by Javad Ahmad, P.E. 2. Glazing complies with ASTM E1300-04 D. QUALITY ASSURANCE 1. Miami -Dade Department of Permitting, Environment, and Regulatory Affairs (PERA). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 11-0325.05 " issued to Solutia, Inc. for their "Saflex and Vanceva clear and color interlayers" dated 05/05/11, expiring on 05/21/16 2. Notice of Acceptance No. 084709.04 issued to Glasslam N.G.I., Inc. for their "Safety -Plus II Laminated Glass" dated 09/11/08, expiring on 08/07/13. F. STATEMENTS 1. Statement letter of conformance, complying with the FBC-2010, and of no financial interest, dated January 4, 2012, signed and sealed by Javad Ahmad, P.E. 2. Florida Dept of State, listing of Trulite Window & Door Solutions, LLC (Foreign Limited Liability Co.), managed by Arch Intermediate Holding, LLC, Tamarac, Fl., dated 02/03/10. 3. Certificate of registration of name change from "Trulite Residential Windows, LLC" to "Trulite Window & Door Solutions, LLC" issued by State of Delaware on 10/28/11, signed by J.W. Bullock. 4. Certificate of registration of name change from "Arch Windows, LLC" to Trulite Residential Windows, LLC" issued by,State of Delaware on 07/27/11, signed by J.W. Bullock. 5. Florida Department of State, listing of Arch Window, LLC (Foreign Limited Liability Co.), managed by Arch Intermediate Holding, LLC, Tamarac, Florida, dated 01/22/10. 6. Certificate of registration of Arch Windows, LLC (Delaware) in State of Florida dated 02/04/10, managed by Arch Intermediate Holding, LLC. G. OTHER 1. Notice of Acceptance No.10-0428.02, issued to Arch Windows, LLC dba AWP, for their Series "2500" Aluminum Single Hung Window — L.M.I.", approved on 08/25/10 and expiring on 12/01/15. Manue z, P.E. Product Contro aminer NOA No.12-0118.18 Expiration Date: December 01, 2015 Approval Date: March 15, 2012 E-2 'THESE WINDOWS ARE RATED-FOR-L-ARGE--&-SMALL: MISSICE-IMPACT.' o`SH.E.1T[ERS ARE NOT REQUIRED. - SERIES P-500 ALUMINUM—SINGLE^HUNG—WINDOW RWADESIGN LOAD RATINGS FOTHE ES PER CHART SHOWN ON SHEETS 2 & 2.1. 53 1/8- WINDOW WIDTH 50 1/4" D.L. OPG. (FIXED) 14 3/8" MAX. FALSE MUNTINS HEAD/SILL FALSE MUNTINS (SURFACE APPLIED) 5" MAX. TYP. (SURFACE APPLIED) MAY BE USED\ n -`j HCAn/slll MAY BE USED II II p u u u u M O n •% u M li li x p U x a ^ o a z ^ .I• z II II W a0 II II 1 N , 11 N II II WINDOWS WIT SILL ANCHORS 48 3/4" WINDOWS WI SHEET 2 SILL AN( D.L OPG. FORE CAPACITIES ^ SEE SHE FOR CAPA 51" a VENT WIDTH t TYPICAL ELEVATION TESTED UNITS APPROVAL APPLIES TO SINGLE UNITS OR SIDE BY SIDE COMBINATIONS OF S.H./S.H. OR SINGLE HUNG WITH OTHER MIAMI-DADE COUNTY APPR'D WINDOWS USING MIAMI-DADE COUNTY APPROVED MULLIONS IN BETWEEN. LOWER DESIGN PRESSURE FROM WINDOWS OR MULLION APPROVAL WILL APPLY TO ENTIRE SYSTEM. THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH-TH �, „ REQUIREMENTS -OF THE_FLORIDA_BUILDING CODE INCLUDING HIGH VELOC `HURRICANE_ZONE,(H.VHZ). WOOD BUCKS BY OTHERS, MUST BE ANCHORED PROPERLY TO TRANSFER LOADS TO THE STRUCTURE. ANCHORS SHALL BE AS LISTED, SPACED AS SHOWN ON DETAILS, ANCHORS EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. ANCHORING OR LOADING CONDITIONS NOT SHOWN IN THESE DETAILS ARE NOT PART OF THIS APPROVAL. A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS, THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE FLORIDA BLDG. CODE SECTION 2003.8.4. 53 1/e" {��¢ WINDOW WIDTH 50 1/4" Z m 0 W N 3 D.L. OPG. (FIXED) 14 3/8" MAX. Q N u. HEAD/SILL 5" MAX. TYP. O 0 o w 0 0 HEAD/SILL A a CORNERS as p � h xgED (7 5 tom o II II �ZN—O It it ei aW2� o B � U o II II II I � 3 N Z II o 04 II 11 (n N O La 48 3/4" o w 3 LO D.L. OPG. 51 " = M7 O VENT WIDTH LAMINATED GLASS Uo LARGE MISSILE IMPACT N En?!-. JAVAD AHMAO I 1 CIVIL`PRODUCI'REVISED a as ,.,I; ng wl the Ploddn I FL. PEN 70592 c CAN. 538 6Uildiug Code - a .. Aoceptmce No 2- .. Expiration Date 15 v E r By9 Miam adeProduct�r`o sheet j of 5 i EQUAL LITES WINDOWS DESIGN LOAD CAPACITY - PSF GLASS TYPES 'A' & 'B' y; WINDOW DIMS.N ANCHORS METHOD 'A' 1ANCHORS-METHOD-'Bt TWIDTHI HEIGHT EXT.(+) 1NT.(-) EXT.(+) 1NT.(-) 119=1/8" 26-1/2" 37" 42" 48" 53-1/8" 26" (3) 70.0 90.0 70.0 90.0 70.0 90.0 70.0 90.0 70.0 90.0 70.0 90.0 70.0 90.0 70.0 90.0 70.0 85.4 70.0 90.0 F 7-0.0 78.0 1 70.0 90.0 19-1/8" 26-1/2" 37" 42" 48" 53-1/8" 38-3/8" (4) 70.0 90.0 1 70.0 90.0 70.0 90.0 70.0 90.0 70.0 90.0 70.0 90.0 70.6 81.5 70.0 90.0 70.0 73.0 70.0 90.0 67.0 67.0 70.0 90.0 19-1/8" 26-1/2" 37" 42" 48' 53-1/8" 50-5/8" (4) 70.0 90.0 70.0 90.0 70.0 81.4 70.0 90.0 64.2 64.2 70.0 90.0 58.3 58.3 70.0 1 90.0 52.5 52.5 60.0 65.0 48.4 48.4 60.0 65.0 19-1/8" 26-1/2" 37" 42" 48" 53-1/8" 59" (5) 70.0 90.0 70.0 90.0 70.0 83.1 70.0 90.0 66.0 66.0 70.0 90.0 60.0 60.2 60.0 65.0 54.5 54.5 1 00.0 65.0 50.3 50.3 60.0 65.0 19-1/8" 26-1/2" 37" 42° 48" 53-1/8" 83" (6) 70.0 90.0 70.0 90.0 70.0 90.0 70.0 90.0 70.0 72.8 70.0V _ .-90.0-3 60.0 65.0 60.0 65.0 60.0 60.2 60.0 65.0 53.3 53.3 60.0 65.0 19-1/8 26-1/2" 37" 42" 48" 53-1/8" 74-1/4" (6) 70.0 90.0 1 70.0 90.0 70.0 74.8 70.0 90.0 58.4 60.0 65.0 53.4 60.0 65.0 48.6 f45.2 60.0 65.0 45.2 60.0 65.0 1 , x wlNnows wlTx SILL ANCHORS • NO. IN PARENTHESIS INDICATE NO. OF -ANCHORS PER JAMB. 1/4" CIA. ANCHORS .�1/4"'OIA.. ANCHORS. AT THIS LOCATION ...AT. THIS LOCATION FOR UPPER HALF OF JAMBS4n,PERA&ALOW � 3/16" DIA. ANCHORS AT THIS LOCATION FOR LOWER HALF OF JAMBS ANCHORS METHOD 'A' ANCHORS METHOD 'B' UNEQUAL LITES (ORIEL TYPES) WINDOWS DESIGN LOAD CAPACITY - PSF GLASS TYPES 'A' & WINDOW DIMS. ANCHORS METHOD 'A' ANCHORS METHOD '8' WIDTH HEIGHT EXT.(+) 1NT.(-) EXT.(+) 1NT.(-) 19-1/8" 26-1/2" 37" 42" 48" 53-1/8" 50-5/8" (4) 70.0 90.0 70.0 90.0 70.0 80.3 70.0 90.0 63.2 63.2 70.0 90.0 57.5 57.5 70.0 90.0 51.9 51.9 70.0 90.0 47.9 47.9 70.0 81.9 19-1/8" 26-1/2" 37" 42" 48° 53-1/8" 59" (5) 70.0 90.0 70.0 90.0 70.0 82.2 70.0 90.0 63.9 63.9 70.0 90.0 58.4 58.4 70.0 90.0 52.9 52.9 70.0 80.4 49.0 49.0 70.0 72.4 19-1/8" 26-1/2" 37" 42" 48" 63" (6) 70.0 90.0 70.0 90.0 70.0 90.0 70.0 90.0 70.0 70.1 70.0 90.0 63.9 63.9 70.0 83.7 58.0 58.0 70.0 74.9 19-1/8" 26-1/2" 37" 74-1/4" (6) 70.0 90.0 70.0 90.0 70.0 74.2 70.0 90.0 58.5 56.5 70.0 73.1 • NO. IN PARENTHESIS INDICATE NO. OF ANCHORS PER JAMB. 1/8" ANN. GLASS 1/8" ANN. GLASS 090 POLYESTER INTERLAYER .090 PVB INTERLAYER SAFETY -PLUS II BY GLASSLAM SAFLEX IIIG BY 'SOLUTIW 1/8" ANN. GLASS 1/8" ANN. GLASS PET FLAP PET FLAP .010" X 5/B" .010" X 5/8° EMBEDED IN SILICONE EMBEDED IN SILICONE SILICONE z m SILICONE z GE 2800 �n GE 2800 I I n o a 2am§&4z:_0 � FOAM TAPE 6 II�{y'�II I I - FOAM TAPE GLASS TYPE 'A' GLASS TYPE `B'. GLAZING OPTIONS Enyr..JAV AHMAD PR CIVIL ' FLA. PEA 70592 ' :PO C.A.N. 538 AC NOTE: GLASS CAPACITIES ON THIS SHEET ARE BASED ON ASTM E1300-04 (3 SEC. GUSTS) `7 Ex AND FLORIDA BUILDING COMMISSION DECLARATORY STATEMENT DCA05-DEC-219 ,PC1 o o n m a vrj drawing no. W05-37 sheet 2 of 5 EQUAL LITES WINDOWS DESIGN LOAD CAPACITY - PSF GLASS TYPE 'C' WINDOW DIMS. ANCHORS METHOD 'A' ANCHORS METHOD 'B' WIDTH HEIGHT EXT.(+) INT.(-) EXT.(+) INT.(-) 19-1/8" 26-1/2" 37" 42" 48" 53-1/8" 26" (3) 60.0 65.0 60.0 65.0 60.0 65.0 60.0 65.0 60.0 65.0 60.0 65.0 60.0 63.3 60.0 65.0 55.4 55.4 60.0 65.0 50.0 50.0 60.0 65.0 19-1/8" 26-1/2" 37" 42" 48' 53-1/B" 38-3/8" (4) 60.0 65.0 60.0 65.0 60.0 65.0 60.0 65.0 60.0 64.9 60.0 65.0 57.2 60.0 65.0 S5.2 50.0 60.0 65.0 45.2 60.0 65.0 19-1/8" 26-1/2" 37" 42" 48" 53-1/8" 50-5/8" (4) 60.0 65.0 60.0 65.0 60.0 05.0 60.0 65.0 49.2 49.2 _ 60.0 65.0 43.3 43.3 60.0 65.0 37.9 37.9 60.0 65.0 34.3 34.3 60.0 65.0 19-1/8' 26-1/2" 37" 42" 48" 53-1/8' 59" (5) 60.0 65.0 60.0 65.0 60.0 65.0 60.0 65.0 52.8 52.8 60.0 65.0 46.5 46.5 60.0 65.0 40.7 40.7 60.0 65.0 36.6 36.8 60.0 65.0 19-1/8' 26-1/2" 37" 42" 48" 53-1/8" 63" (6) 60.0 65.0 1 60.0 65.0 60.0 65.0 _ 60.0 65.0 59.3 59.3 60.0 65.0 52.2 52.2 60.0 65.0 45.7 45.7 60.0 65.0 41.3 41.3 60.0 65.0 19-1/8" 26-1/2" 37" 42" 48" 53-1/8" 74-1/4" (6) 60.0 65.0 60.0 65.0 60.0 65.0 60.0 65.0 50.3 50.3 1 60.0 65.0 44.3 44.3 60.0 65.0 38.8 38.8 60.0 65.0 35.0 35.0 60.0 65.0 W WINDOWS WITHOUT SILL ANCHORS • NO. IN PARENTHESIS INDICATE NO. OF ANCHORS PER JAMB. 1/4" DIA. ANCHORS 1/4" DIA. ANCHORS AT THIS LOCATION AT THIS LOCATION FOR UPPER HALF OF JAMBS FOR UPPER & LOWER HALF OF JAMBS 3/16" DIA. ANCHORS AT THIS LOCATION FOR LOWER HALF OF JAMBS •ANCHORS METHOD 'A' ANCHORS METHOD 'B' UNEQUAL LITES (ORIEL TYPES) WINDOWS ➢ESIGN LOAD CAPACITY - PSF GLASS TYPE 'C' WINDOW DIMS. ANCHORS METHOD 'A' ANCHORS METHOD 'B' WIDTH HEIGHT EXT.(+) INT.(-) EXT.(+) 1NT.(-) 19-1/8" 26-1/2" 37' 42" 48" 53-1/8" 50-5/8" (4) 60.0 65.0 60.0 65.0 60.0 65.0 60.0 65.0 49.2 49.2 60.0 65.0 43.3 43.3 60.0 65.0 _ 37.9 34.3 37.9 _ -34.3 60.0 60.0 65.0 65.0 19-1/8" 26-1/2" 37" 42' 48" 53-1/8" 59" (5) 60.0 65.0 60.0 65.0 60.0 65.0 60.0 65.0 52.8 52.8 60.0 65.0 46.5 46.5 60.0 65.0 40.7 40.7 60.0 65.0 36.8 36.8 60.0 65.0 19-1/8" 26-1/2" 37" 42" 48' 03" (5) 60.0 65.0 60.0 1 65.0 60.0 65.0 60.0 65.0 59.3 59.3 60.0 65.0 52.2 52.2 60.0 65.0 45.7 45.7 60.0 65.0 19-1/8 26-1/2" 37" 74-1/4" (6) 60.0 65.0 60.0 65.0 60.0 65.0 60.0 65.0 50.3 50.3 60.0 65.0 • NO. IN PARENTHESIS INDICATE NO. OF ANCHORS PER JAMB. i NOTE: GLASS CAPACITIES ON THIS SHEET ARE BASED ON ASTM E1300-04 (3 SEC. GUSTS AND FLORIDA BUILDING COMMISSION DECLARATORY STATEMENT DCA05-DEC-219 � o w $ � a q� o F 3 K 6 - = c 5 F 2 c vo Ii Yi c - GLASS TYPE 'C' ` O Engr.^ UAV 0"AHMAD m r o PRODUCT' REVISED FTA PE'#470592 rscomptyinswith thoPlorlds C.A.M. 3538 Building Code "D IB/ 8 - s n Accaptanoe No o aQ�y' Ex iration Doto !,> L By drawin no. Miami deikodud o1 9 W05-37 sheet 2.lof 5 ANN. GLASS .090 PVB INTERLAYER SAFLEX IIIG BY 'SOLUTIA' 1/8" ANN. GLASS \ SILICONE `GE 2800 TYPICAL ANCHORS METAL SEE 1/4" TAPCONS 1BY Y o: STRUCTURE WOOD BUCKS AND METAL STRUCTURE NOT BY TRULITE /1�4 M ELEV. FOR SPACING �V WGOO BUCK . x MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM m TYPICAL ANCHORS n ° ° e 1 d. o �t4 SMS AND TRANSFER THEM TO THE BUILDING STRUCTURE. Z n 3 o SEE ELE.VS. FOR SPACING 0 t• m CAtL ANCHORS:�S ELEV. FOR SPACING Q w Zd TYPI N a .�(S E SHEET 2 FOR USE OF 3/16" TAPCONS) Q' p c o INTO 211Y WOOD BUCKS OR WOOD STRUCTURE O1-3/8" MIN. PENETRATION INTO WOOD p _ = THRU 1BY BUCKS INTO CONC. OR MASONRY C t n 1-1/4" MIN. EMBED INTO CONIC. OR MASONRY V o ro cy 0 wIn o 7TYP�I�CAL ANCHORS DIRECTLY INTO CONC. OR MASONRY It TAPCONS SEE ELEVS. FOR SPACING 1-1/ 4" MIN. EMBED INTO CONC. OR MASONRY 0 0 I I 19 N 00 � 914 SMS OR SELF DRILLING SCREWS (GRADE 5 CRS) Q w '0 a 24 _ --- _ --- _------ INTO METAL STRUCTURES LL _� IMAMI—DARE COUNT! APPROVED I I STEEL : 12 GA MIN. (Fy = 36 KSI MIN.) z IMULLION & MULLION ANCHORS I i ALUMINUM : 1/8" THK. MIN. (6063—T5 MIN.) Q m o !i y 9 SEE SEPARATE NOA i (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) 0 J it jl I 11 V #12 SMS OR SELF DRILLING SCREWS s o I I I "� qq I 1g ___ ____ _ __-_—_ - j INTO MIAMI—DADE COUNTY APPROVED MULLIONS 3 z w (NO SHIM SPACE) $ m it it '--• •-- z Fj N !lii ` 11 ANCHOR EDGE DISTANCES M INTO CONCRETE AND MASONRY = 1-3/4" MIN. INTO WOOD STRUCTURE = 3/4" MIN. $ 'd .j 4 OPTIONAL TO TYPICAL ANCHORS INTO METAL STRUCTURE = 1/2" MIN. ii ii 16 20 BOTTOM LATCH #12 SMS z o O SEE ELEV. FOR SPACING $ M o W a Y SEALANTS: g^ g z3 m z W ALL JOINTS AND FRAME CONNECTIONS SEALED WITH o Ni O 5 SCHNEE MOREHEAD SEAM SEALER SM5555, w z M frj 23 � I,pj p 12 j WEEPHOLES' I. i Wl = 3/4" WEEP NOTCH AT EACH END 3 a o 0 d 62g�p o6� S m i 1 z � I 6 14 TYPICAL ANCHOR$ d °d, I 1/4" TAPCONS .° o o N Fl 11_VL 2 USE WHEN REQUIRED y 61,8 0 1 SEE SHEET 2 FOR CAPACITIES a m o O W1 SEE ELEV. FOR SPACING 0 C � a � � b Engr.'iACMLM • PRODUCT REVISED 41''LA. PE 70592 Is complying wllh lho Florida c � . ...a CAN. Sd � .B p�celun�ce � , Cx irerion Date o Code x O drawing no. Munn, ProductContr W05-37 sheet 3 of 5 ITEM PART If REQD. DESCRIPTION MATERIAL - MANF./SUPPLIER/REMARKS 1 YE-169 1 FRAME HEAD 6063-T6 - 2 YE-167 I FRAME SILL 6063-T6 3 YE-102 2 FRAME JAMB 6063-T6 - 4 YE-152 1 FIXED RAIL 6063-T6 6063-TG - - 5 YE-151 1 VENT TOP RAIL 6 YE-168 1 VENT BOTTOM RAIL 6063-T6 - 7 YE-92 2 VENT JAMB 6063-T6 - 8 YB-4 AS REQD. GLAZING BEAD ALUMINUM ROLL FORMED 9 YH-518 2/ VENT SASH STOP RIGID VINYL - 10 - 2/ VENT BLOCK & TACKLE BALANCE - - 11 YH-505 2/ VENT BALANCE CLIP ALUMINUM - 12 YH-622 AS REQD. BULB W'STRIPPING VINYL SINGLE ROW 13 YH-4004 AS REQD. FIN SEAL W'STRIPPING .187 X .250 WOOL ULTRAFAB 14 YH-504 2/ VENT SPRING LOADED VENT LATCHES NYLON/CELCON AT 11" FROM ENDS 14A YH-515 2/ VENT SWEEP LOCKS ZAMAK AT 11" FROM ENDS 15 YF-1 8 FRAME ASSEMBLY SCREWS (#10 X 3/4°) CRS PLATED, PH SMS 16 YF-10 2/ VENT FIXED RAIL SCREWS (#8 X 1") CRS CAD PLATED, PH SMS 17 YF-12 6/ VENT VENT ASSEMBLY SCREWS (#B X 1-1/4' CRS CAD PLATED. PH SMS 19 YF-6 1/ CLIP #10 X 1/4" PH SMS POINT B - - 20 YF-14 2/ LOCK SWEEP LOCK SCREWS (#8 X 5/8' - OH SMS 21 YC-15SP 2/ VENT SELF ADHESIVE PAD (.375" X .31" X .75") FOAM - 22 YH-519 2/ VENT BALANCE CAM PLASTIC - 23 YH-519 1 REINFORCING BAR (.627 X .312") STEEL HRB93 24 - 2/ VENT SASH STOP (1" X 1-1/4" X 1/16") ALUMINUM ON 74-1/4" HIGH ONLY L ANCHORS LEV. FOR SPACING HEET 2 & 2.1 FOR CAPACITY 1/4" SHIM SEE SHEET 2 & 2.1 FOR CAPACITY BUCK LTYPICAL ANCHORS SEE ELEV. FOR SPACING SEE SHEET 2 & 2.1 FOR CAPACITY U o< m m 0 m w Engr. LAVAU AHMAD CIWL PRODUCTREVISBD I N II 0 'FLA. PEA 70592 nacomplying ivithliteFloiidn c CAN. 538 l Bq;Iding Code •, AcoepmnoeNo�ei Dote (� j L•rcirolion A4iatn' Product O W05-37 sheet 4 of 5� �2.220 089 k.055 1.327 .827 .860 {-- FRAME HEAD .812 -�I .062 ee� I1.437 �L1.a62�1 FIXED RAIL r.999� 1.187 .055 �IIL�11 1.625 —I .elz VENT TOP RAIL im VENT BOTTOM RAIL FRAME SILL 1.1251 1.070 5555 .812 .687 L VENT SIDE RAIL W .930 !� A551.292 2.1L 04 812 p IIa-1.617 FRAME JAMB 3/4" WEEP AT EACH E SCREEN REMNIU 31�0 S.H. VENT CORNER DETAIL V�3 17 M I N 0 Z n S W N Q f N 5 O: 0o W M U d � o � c m 0'0>e10 0 aaa 0`3�L3 Q ix ww 3 w- N LLzN= M aW O n J j 17 N o y � n 0 M Z to CD C ¢ �0 Z C3 ^J z 3u 8 �z� OJ � M W N 0 o�y4F2oa� °9 .111 0 Endn JAVAD AHMAD CML PRODUC7'REVISED ,b N 1 II o FIA. PE 70592 C.a N. 538 as complying with the FloLtda Balld ng Coda r I Amp an IN • Ex imtion to l5 e 0 By bham do Product Con of drawing no. �Q� sheet g of 5 NOTICE OF PRODUCT CERTIFICATION Company: Masonite International Corporation Certification No.: NI006110.01 1955 Powis Road Certification Date: 07/23/2005 West Chicago, IL 60185 Expiration Date: 12/31/2014 Revision Date: 09/27/2011 Product: Wood -Edge Steel Opaque Inswing or Outswing Door w/ and w/o Non -Impact Rated Sidelites (w/Wood Frame unless noted) Specifications Tested To: TAS 201-94/202-94/203-94 The "Notice of Product Certification" is only valid if the NAMI Certification Label has been applied to the product as described within this document. The certification label represents product conformity to the applicable specification and that all certification criteria has been satisfied. This product has been approved for listing within NAMI's Certified Product Listing at www.Namicertification.com. NAMI's Certification Program is accredited by The American National Standards Institute (ANSI). Configuration Inswing Glazed Structural Water Missile Test Report Number or or Maximum Design Test Impact Drawing Number & Outswing Opaque Size Pressure Pressure Rated Comments X I/S Opaque 3'0" x 6'8" +76/-76 2.86 psf Yes NCTL-210-2929-1 Single Maximum Panel Size: 3'0" x 6'8" Anchor Detail-MA-FL0128-05 X O/S Opaque 310" x 6'8" +76/-76 8.25 psf Yes NCTL-210-2929-1 Single Maximum Panel Size: 3'0" x 6'8" b' Anchor Detail-MA-FL0128-05 XX I/S Opaque 6'0" x 6'8" +55/-55 2.86 psf Yes NCTL-210-2930-1 Double Maximum Panel Size: 3'0" x 6'8"/Sidelite: 3'0" x 6'8" Anchor Detail-MA-FL0128-05 XX O/S Opaque 6'0" x 618" +55/-55 8.25 psf Yes NCTL-210-2930-1 Double Maximum Panel Size: 3'0" x 6'8"/Sidelite: 3'0" x 6'8" Anchor Detail-MA-FL0128-05 XO/OX I/S Opaque Door 6'0" x 618" +55/-55 2.86 psf Door -Yes NCTL-210-2930-1 Single w/Sidelite g Glazed Sidelite Sidelite-No Maximum Panel Size: 3'0" x 6'8"/Sidelite: 3'0" x 6'8" Anchor Detail-MA-FL0128-05 XO/OX O/S Opaque Door 690" x 6'8" +55/-55 8.25 psf Door -Yes NCTL-210-2930-1 Single w/Sidelites Glazed Sidelite Sidelite-No Maximum Panel Size: 3'0" x 6'8"/Sidelite: 3'0- x 6'8" Anchor Detail-MA-FL0128-05 OXO I/S Opaque Door 910" x 6'8" +551-55 2.86 psf Door -Yes NCTL-210-2930-1 Single w/Sidelites Glazed Sidelites Sidelites-No Maximum Panel Size: 3'0" x 6'8"/Sidelite: 30" x 6'8" Anchor Detail-MA-FL0128-05 OXO O/S Opaque Door 910" x 618" +55/-55 8.25 psf Door -Yes NCTL-210-2930-1 Single w/Sidelites Glazed Sidelites Sidelites-No Maximum Panel Size: 3'0" x 6'8"/Sidelite: 3'0" x 6'8" Anchor Detail-MA-FL0128-05 OXXO I/S Opaque Doors 12'4" x 6'8" +55/-55 2.86 psf Doors -Yes NCTL-210-2930-1 Double w/Sidelites Glazed Sidelites Sidelites-No Maximum Panel Size: 3'0" x 6'8"/Sidelite: 3'0" x 6'8" Anchor Detail-MA-FL0128-05 OXXO O/S Opaque Doors 12'4" x 6'8" +55/-55 8.25 psf Doors -Yes NCTL-210-2930-1 Double w/Sidelites Glazed Sidelites Sidelites-No Maximum Panel Size: 3'0" x 6'8"/Sideli e: 3'0" x 6'8" Anchor Detail -MA -FL -8- 5 National Accreditation &Management Institnte, Inc./4794 George Washington Memorial Highway/Hay _ ,� 30J2 Tel: (804) 684-5124/Fax: (804) 684-5122 NAMI AUTHORIZED SIGNATURE: /wa:Ifln2 ?'B° SIDE -HINGED WOOD -EDGE STEEL DOOR UNIT &-8" DOUBLE DOOR WITH/ WITHOUT SIDELITES GENERAL NO7E5 1. ��pPAALT1ATE03F OGA 5 AOHEgg@@@LNG ITHE#FLOR%1A� LDXJG CDDE AND VIHEREE�y.,4UREf [ EOUIREMENTS><A,�DETERMINEDI U MINiMU ESIGNTOADS FOR BUILDINGS AND OTH STRUCTURES, DOES NOT EXCEED THE DESIGN PRESSURES LISTED. 2. HURRICANE PROTECTIVE SYSTEM (SHUTTERS) IS NOT REQUIRED ON OPAQUE PANELS, BUT IS REQUIRED ON GLAZED SIDELITES. 3. IN THE HVHZ. FACTORY PRIMED DOORS MUST BE PAINTED IN ACCORDANCE WITH SECTION 2220 OF THE FBC. 4. POLYURETHANE CORE FLAME SPREAD INDEX OF 50 AND SMOKE DEVELOPED INDEX OF 60 PER ASTM E84. S. PLASTICS TESTING OF LITE FRAME MATERIAL: TEST DESCRIPTION DESIGNATION RESULT SELF IGNITION TEMP ASTM D1929 740 'F > 650 'F RATE OF @URNINC ASTN 06J5 0.77 IN MIN SMOKE DENSITYI ASTM D2843 1 13.4% TENSILE STRENGTH- I ASTM D638 1 7.50% RIFF • COMPARATIVE TENSILE STRENGTH AFTER WEATHERING 4500 HOURS XENON ARC METHOD 1 TABLE OF OF CONTENTS SHEEP f I DESCRIPTION 1 TYPICPL EI_EVATIONS & GENERAL NOTES 2 ANCHORING LOCATIONS & OETAILS 3 ANCHORING LOCATIONS & DETAILS 149' MAU. OVERAU FRAME W I TH 21' MAX 16.375- MAX. - D.L.O. PANEL WIDTH 37.5" MAX. W/ASTRAGAL FRAME WIDTH cq Ci S J bO A r a DESIGN PRESSURE RATING WHERE WATER INFILTRATION PERFORMANCEIS REQUIRED TO BE 15% OF DESIGN PRESSURE CONFIG MAX WIDTH INSWING OUTSWINC INSWING OU S I G X W, +76.0 -76.0 +78.0 -76.0 +19.0 -19.0 +55.0 XX 74 + 5.0 -5 .0 +55.0 -55.0 +19.0 1 -19.0 +5 .0 OX or XO 7 + -55.0 .0 .0 +19.0 -19.0 +55.0 -19.0 +SS.O OXXO 149 +55.0 -55.0- +55.0 -55.0 +19.0 -19.0 1 + 5.0 .0 AdkIftI0MA10 cgffww Nx IJ(eQ(. ILa y Dateflemr�i 7�(l� 4 i 09 KURT BALTHAZOR FLORIDA P.E. J56533 cc 00 O � Qq� � � 1 Z c u Z U u ti Ln T Lr)U I SEE DETAIL "C" SHT. 2 A n ATTACHMENT DETAIL 1. ANCHOR ANALYSIS FOR LOADING CONDITIONS PREPARED, SIGNED AND SEALED BY LUIS R. LOAAS, PE (FLORIDA #62514) WITH THE LOWEST (LEAST) FASTENER RATING FROM THE DIFFERENT FASTENERS BEING CONSIDERED FOR USE. JAMB, HEAD, AND THRESHOLD FASTENERS ANALYZED FOR THIS UNIT INCLUDE #10 WOOD SCREWS OR 3/16' TAPCONS. A PHYSICAL SHIM MUST BE PLACED IN SHIM SPACE AT EACH ANCHOR LOCATION. TAPCON EDGE DISTANCE MIN 2-1/2 2. MULLIONS TO BE 2-1/2" X 4-3/8" STRUCTURAL GRADE FJ PINE ON CONTINUOUS HEAD AND SILL UNITS. BACK TO BACK JAMB UNITS JOINED WITH 1" X 1/2" LONG CORRUGATED FASTENERS LOCATED 3" FROM EACH END AND MAXIMUM 7" O.C. OR #10 X 2" FLAT HEAD WOOD SCREWS LOCATED 6" FROM EACH END AND MAXIMUM 12" O.C. 3. THE WOOD SCREW SINGLE SHEAR DESIGN VALUES COME FROM ANSI/AF&PA NDA FOR SOUTHERN PINE LUMBER AND ACHEIVEMENT OF 1-1/2" MINIMUM EMBEDMENT. THE TAPCON MUST ACHIEVE MINIMUM EMBEDMENT OF 1-1/4". 4. WOOD BUCKS BY OTHERS MUST BE ANCHORED PROPERLY TO TRANSFER LOADS TO STRUCTURE. 5. MINIMUM DESIGN VALUE STRENGTH OF ANCHORS 171 LBS. b 6" L I n o N a SEE DETAIL N "D" SHT. 2 a C W s Y C I I I — I I I— 6" I I I _ h W W e IAll 1AII I I a }" -4 6 } 6" } Al 6" 6' r MCRnWCRG CT:NFnl 11 F 1, KWIKSET SERIES 400 GRADE 3 CYLINDRICAL LATCH AND SERIES 980 GRADE 1 DEADLOCK HARDWARE TO BE INSTALLED AT 5-1/2" CENTERLINE. 2. 4" X 4" FULL MORTISE BUTT HINGES s. IMSH " �. ` MAX" SHIM CL — I_ TYPICAL WOOD BUCK ANCHOR INSTALLATION 'MIN" .R 0M.p2K' SHIM CL TYPICAL MASONRY ANCHOR INSTALLATION AdbdtnloNW ate 6' SEE DETAIL ..I 6' J- 3^ �n SEE DETAI A 3' .1 L^I e o W < a SEE DETAIL tt rc O � Z #8 x 2-1/2" #10 x 2" #8 x 2-1/2" #10 x 5/8" #8 x 2-1/2" #10 x 1" #10 x 5/8" 0 #10 x 3/4" #10 x 2" DETAIL "E" ASTRAGAL FRAME / DOOR ATTACH ASTRAGAL RETAINER BOLT PLATE TO DETAIL "D DETAIL "C„ STR1K AS SHOWN. FRAME TYPICAL AftrdmtDMW 0.962" 1 cHdfi�IMNO: r "n 6 n e- a 17 Dae1.375* INSWING THRESHOLD OUTSWING THRESHOLQ M S. I n, EE DETAIL H 6" ASTRAGAL RETAINER BOLT HOLE MUST BE DRILLED THROUGH THE THRESHOLD & INTO THE STRUCTURE DEEP ENOUGH iiiiFOR A 1.375" THROW ,DETAIL "F" ASTRAGAL GOW 896� IG 0/e• TEMP. GLASS) STM RECGRANE INSERT AL GPR AlV4, SiEEI OR BUTYL SPACER ,/z• � �r6 x i-I/2• PHS GDW so iX1E019d '•�'^•:4 PiiTE81ffi TYPICAL GLAZING DETAIL a In E4 OD J p�J zoo o� zap U U z� ti g ^W Luis R. Lomas P. E. 1432 Woodford Rd. Lewisville, NC 27023 Manufacturer: Masonite Report #: 504A 336-945-9695 Date: 12/29/09 Single. Pressure against stops with saddle threshold: 36.38 Design pressure: 85.0 psf ]IA2 79.25 Anchor Locations: 36.38 18.19 6.00 TYP. 6.00 TYP. l 6.00 79.25 f 13.45 MAX.. O.C. 1 1- 6.00 Max. Anchor Zone Area Load Ind. O.C. Result Cap. Load (ftZ) (Ibs) (in) QtY (in) (Ibs) (Ibs) Al 2.3 195 N/A N/A 171 2 98 OK AZ 8.9 753 6.00 18.00 171 5 151 OK Note: Anchor locations indicated in this document are the minimum required for the described product exposed at the design pressure indicated herein. 2 of 2 011 I111//// ♦N� g R L 0 �// ♦, J� ' * •0.51 • TAT OF •� s/ONAL.IE\\��`� Luis R. Lomas P.E. FL No.: 62514 1/7/2010 Luis R. Lomas P. E. 1432 Woodford Rd. Manufacturer: Masonite Lewisville, NC 27023 Report #: 504A 336-945-9695 Date: 12/29/09 Product: Single Door 3'x6'8" Scope: This analysis provides calculations, quantities, and spacing requirements for installing product to substrate, and it applies only to the product described herein. These calculations comply with requirements of the Florida Building Code. Drawings verification: This analysis verifies anchoring for the following drawings: DWG-MA-FLO120-05 DWG-MA-FLO130-05 DWG-MA-FLO153-06 DWG-MA-FLO168-07 DWG-MA-FLO122-05 DWG-MA-FLO132-05 DWG-MA-FLO155-06 DWG-MA-FLO170-07 DWG-MA-FLO124-05 DWG-MA-FLO134-05 DWG-MA-FLO156-06 DWG-MA-FLO172-07 DWG-MA-FLO126-05 DWG-MA-FLO140-05 DWG-MA-FLO160-07 DWG-MA-FLO174-07 DWG-MA-FLO128-05 DWG-MA-FLO151-06 DWG-MA-FLO162-07 DWG-MA-FLO175-07 Anchors to be Qualified: 1. #10 Wood screw, for installation in wood frame substrates. 2. 3/16" ITW Tapcon, for masonry installation Anchor capacity In shear condition: Fastener type: #10 wood screw (NDS 2005,11.3) Side member: Douglas Fir -Larch Main member: Spruce -Pine -Fir Side member thickness: t,= 1.000 in Main member thickness: tm= 1.500 in Side member dowel bearing strength: F. = 4,650 psi Main member dowel bearing strength: F. = 3,350 psi Minimum required penetration: 1.330 in Screw bending yield strength: Fyb = 80,000 psi Duration Factor: Co = 1.6 Tabulated lateral design value: Z= 107.0 Ibs Allowable Design Value: Z'= 171 Ibs/anchor Mode IV Fastener type: 3/16" ITW Topcon N.O.A. 07-1126.10 Substrate: Hollow block Minimum embedment: 1.25 in Minimum edge distance: 1.13 in Minimum C to C spacing: 2.25 in Tabulated shear design value: Z = 112 Ibs Actual C To C spacing: 3.00 in Minimum edge distance: 2.63 in C to C spacing factor: 1.00 Tabulated shear design value: Z = 197 Ibs Actual edge distance: 2.50 in Design value per interpolation: Z = 189 Ibs Allowable Design Value: Z'= 189 Ibs/anchor Minimum anchor capacity: 171 Ibs/anchor Note: Anchors with the least capacity is used for calculations to qualify anchors with higher capacity. Anchor calculations, minimum required anchors Pressure against stops with bump threshold: 36.38 ]2A2 t 79.25 Single. Pressure away from stops: 36.38 1 of 2 Design pressure: 85.0 psf Zone Area (ft2) Load (Ibs) Ind. (in) Max. O.C. (in) Anchor Result Cap. (Ibs) Q Load (Ibs) Al 2.3 195 N/A N/A 171 2 98 OK A2 7.7 656 6.00 18.00 171 5 131 OK Design pressure: 85.0 psf Zone Area Load Ind. Max. O.C. Anchor Result Cap. Load z (tt) (Ibs) (in) QtY (in) (Ibs) (Ibs) Al 10.0 851 6.00 18.00 171 5 170 OK 0\1killf///� �,� g R • 'L 0/�q���i \�N_\\ . • • • . - I • .��C, E 1V S,�'9cS� �•rJ *• 0 QD51 •*_ TAT , OF •; • (I.I Luis R. Lomas P.E. �o`:c� OR10P • ����` FL No.: 62514 Fs . • • • . !� �� 1/7/2010 ,,��s/ONA"��1\�,. Lumber design values are in accordance with ANSI/TPI 1-2007 section 6.3 These truss designs rely on lumber values established by others. MiTek RE: 24208 - MiTek USA, Inc. Site Information: 6904 Parke East Blvd. Customer Info: Robert Britton Project Name: Britton Residence Model: Addition Tampa, FL 33610 4115 Lot/Block: Subdivision: Portofino Shores Address: 5812 Spring Lake City: Ft. Pierce / St Lucie State: FI Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: State: General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2010/TP12007 Design Program: MiTek 20/20 7.3 Wind Code: ASCE 7-10 Wind Speed: 170 mph Floor Load: N/A psf Roof Load: 55.0 psf This package includes 2 individual, dated Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61 G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. No. ISeal# I Truss Name Date 1 IT4602760 IA01 11 /6/012 12 I T4602761 I A02 1 11/6/012 1 �{111UljL The truss drawing(s) referenced above have been prepared by MiTek V, .S 41 1.4 . Industries, Inc. under my direct supervision based on the parameters provided by East Coast Truss. �+�1*X1.• E�N• ;�'',� '. Truss Design Engineer's Name: Magid, Michael ;' No 536 My license renewal date for the state of Florida is February 28, 2013. NOTE:The seal on these drawings indicate acceptance of = professional engineering responsibility solely for the truss 'r14 ., STATE OF 47 *4 P 9 9 P tY Y ar ,. for ancompyents particular building is responsibility o sibiand f of this of the building '�t� , 1, 0 R I P `_ ` designer, per ANSI/TPI-1g Sec. 2. P ty gfill, 111110 FL Cert. 6634 November 6,2012 Magid, Michael 1 of 1 Job Truss Truss Type Oty Ply T4602760 24208 A01 COMMON TRUSS 1 1 Job Reference (optional) East Coast Truss, Fort Pierce, FL 34946 7.350 s Sep 26 2012 MTek Industries, Inc. Tue Nov 0614:44:22 2012 Page ID:W9DCfFBnTSR5y??8NIoZRyLuUD-bPdENcC84la94NIaWPbd6gOPAnWV 3Nzo?hAwyLu a 1 1 9-8-0041 Scale: 3/8"=T 4x4 = 5 1x4 II 1x4 II' 5.00 12 4 6 1x4 It 1x4 II 3 7 W II s 1 L]L� I$ lxxxxxxxyyyyyy 3x4 = 3x4 = 16 15 14 13 12 11 10 - 1x4 II W I I 1x4 II 5x5 = 1x4 II 1x4 II W I I 1-a0 i 19-4-0 1-a0 18-4-0 Plate Offsets X 13:0-2-8 0-3-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 30.0 Plates Increase 1.33 TC 0.44 Vert(LL) n/a - n/a 999 MT20 244/190 TCDL 15.0 Lumber Increase 1.33 BC 0.32 Vert(TL) n/a - n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.17 Horz(TL) -0.01 10 n/a n/a BCDL 10.0 Code FBC201 O/1'PI2007 (Matrix) Weight: 85 lb FT = 5% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 10-0-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. OTHERS 2x4 SP No.3 MTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS All bearings 17-4-0. (lb) - Max Horz 16=98(LC 7) Max Uplift All uplift 100 lb or less atjoint(s) 14, 15, 16, 12, 11, 10 Max Grav All reactions 250 lb or less at joint(s) 15, 11 except 13=479(LC 2), 14=297(LC 19), 16=590(LC 19), 12=297(LC 20), 10=590(LC 20) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-2=71/466, 2-3=-4/401, 3-4=0/431, 4-5=0/417, 5-6=0/417, 6-7=0/431, 7-8=4/401, 8-9=71 /466 BOT CHORD 1-16=359/84, 15-16=359/84, 14-15=359/84, 13-14=359/84, 12-13=359/84, 11-12=359/84, 10-11=359/84, 9-10=-359/84 WEBS 5-13=-445/0, 2-16=-407/108, 8-10=407/108 %%J11111111j1 'kS Unbalanced roof live loads have been considered for this design. %NOTES��Q�;.•v/9 �' 2) Wind: ASCE 7-10; Vuft=170mph (3-second gust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp G E NS•'.•(�1/ � �% ,�,• C B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate \,� � grip DOL=1.60 No 53681 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gabl = * End Details as applicable, or consult qualified building designer as per ANSIrrPI 1-2002. �. 4) Gable studs spaced at 2-0-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurent with any other live loads.IV 6) • This truss has been designed fora live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will ft �� S TAT EkF'between t'7) the bottom chord and any other members. Provide mechanical connection (by others) oftruss to bearing plate capable ofwithstanding 100 Ib uplift atjoints) 14, 15, 16, 12, 11, 10. 1# ,� A-: R 0 /emi-rigid �\ 9) S'• s• 1, pitchbreaks Including heels" Member end fixity model was used in the analysis and design of this truss. 0�j CSC 'O �1 bracing for truss this design) is ��Ij ,�O �` `��% 10) Warning: Additional permanent and stability system (not part of component always required. N A1- �!!l1f111111��, LOAD CASE(S) Standard FL Cert. 6634 November 6,2012 • A WARfMVG - Per{jy dafgn parmneters and READ N078S ON THIS AND INCLUDED AffFfCRBFBRBdYCB PAGE AU-7473 BEFORB USE, �■■ Design valid for use only with MiTek connectors. fits design Is based only upon parameters shown, and is for an Individual building component. Applicability of design parameters and proper incorporation of component Is responsibility of building designer- not truss designer. Bracing shown Is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction Is the responsiblGty of the MiTek• erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/rPll Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke Fast Blvd. Safety Inlormaflon available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria. VA 22314. Tampa, FL 33610-4115 If Southern Pine (SP or SPp) lamberts specifiedl, the design values are those effective 0610//2012 by ALSC or pmposed by SPI6. Job Truss Truss Type Qty Ply T4602761 24208 A02 COMMON TRUSS 4 1 Job Reference (optional) East Coast Truss, Fort Pierce, FL. 34946 7.350 s Sep 26 2012 MTek Industries, Inc. Tue Nov 06 14:44:24 2012 Page ID: W9DCfFBnTSR5y??BNIoZRyLuUD-Yol?oHEOcMgtJhvzdgvPkXwlazN nztzgQ6UoEpyLuS 0. 12- 1 1 1-4-0 5.1-3 1 -13 3.2-13 Scale = 1:32.4 4x4 = 4 5.00 12 1x4 1x4 3 m 5 1x4 II 1x4 II 2 6 1 7 I$ 9 _ 3x4 = 10 _ 5x8 B 1x4 11 3x4 = 1x4 II 1-0.0 1 9-8-0 18.0-0 1 1s-0-o 1-0-0 6 8-4-0 B-4-0 Plate Offsets X 2:0-2-7 0-0-8 6:0-2-7 0-0-8 8:0-2-3 0-0-8 9:0-4-0 0-3-0 10:0-2-3 0-0-8 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Udell L/d PLATES GRIP TCLL 30.0 Plates Increase 1.33 TC 0.65 Vert(LL) -0.09 9 >999 240 MT20 244/190 TCDL 15.0 Lumber Increase 1.33 BC 0.68 Vert(TL) -0.21 9-10 >947 180 BCLL 0.0 Rep Stress Incr YES WB 0.21 Horz(TL) 0.04 8 Na n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight: 79 lb FT = 5% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-0-10 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10.0-0 oc bracing. WEBS 2x4 SP No.3 MiTek recommends that Stabilizers and required cross bracing be Installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 10=918/043-0 (min. 0.1-8), 8=918/0-B-0 (min. 0-1-8) Max Horz 10=98(1_C 6) Max Uplift 10=204(LC 8). 8=164(LC 8) Max Grav 10=1063(LC 2), 8=1063(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-2=1233/628, 2-3=1503/267, 3-4=1165/228, 4-5=1165/229, 5-6=1503/268, 6.7=1233/628 BOT CHORD 1-10=861/1289, 9.10=161/1289, 8-9=163/1289, 7-8=861/1289 WEBS 4-9=101/554, 5-9=371/130, 3-9=371/127, 2-10=758/256, 6-8=758/237 NOTES 1) Unbalanced roof live considereds have been 2) Wind: ASCE 7-10; Vufta170mph (3 econdgust) Vasd=132mph; TCDL=9.Opsf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft; eave=oft; Cat. 11; Exp �v** left left Lumber DOL=1.60 B; Encl., GCpi=0.18; MWFRS (directional); cantilever and right exposed ; end vertical and right exposed; plate ........ .. . grip DOL=1.60 ���,,G�P v- s��'.•�� 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-60 tall by 2-0-0 wide will fit : N 0 53681 between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 10=204..; 8=164. ' 6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. .� = 7) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. :. STATEkF 4 LOADCASE(S) Standard���• FL Cert. 6634 November 6,2012 .A WARNING -Verify design pararrwtem andREdO N07ES ON 77US AND INCLUDED AUTEKREFEi EMB PAGE JGZ-7473 BEFORE US& Design valid for use only with Welk connectors. This design Is based only upon parameters shown, and is for an individual building component. ��• Applicability of design parameters and proper incorporation of component Is responsibility of building designer - not truss designer. Bracing shown is for lateral support of Individual web members only. Additional temporary bracing to insure stability during construction is the responsibilrity of the MiTek' erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312. Alexandria, VA 22314. Tampa, FL 33610-4115 IT Southem Pine i SP or SPp) lumber is specified, the design values are those effective 061812012 by ALSC or proposed by SPHL Symbols I Numbering System A General Safety Notes PLATE LOCATION AND ORIENTATION 3/4 Center plate on joint unless x, y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and fully embed teeth. 0-rw, For 4 x 2 orientation, locate plates 0-'na' from outside edge of truss. This symbol indicates the required direction of slots in connector plates. Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the plate 4 x 4 width measured perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING LOCATION Indicated by symbol shown and/or by text in the bracing section of the output. Use T or I bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Min size shown is for crushing only. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 6-4-8 dimensions shown in ft4n-sixteenths (Drawings not to scale) Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.9. 1 2 3 diagonal or X-bracing, is always required. See BCSI. TOP CHORDS cr-2 c2a 2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves WEBS 4 c� may require bracing, or alternative Tor I ce- Oaf z b �� 3 srv� 3O bracing should be considered. 3. Never exceed the design loading shown and never U Dp = stack materials on inadequately braced trusses. a_ O U o- 4. Provide copies of this truss design to the building ~ c7.8 c6-7 cs-6 O designer, erection supervisor, property owner and all other interested parties. BOTTOM CHORDS JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. PRODUCT CODE APPROVALS ICC-ES Reports: ESR-1311,ESR-1352,ESR1988 ER-3907, ESR-2362, ESR-1397, ESR-3282 Southern Pine lumber designations are as follows: SYP represents current/old values as published by AWC in the 2005/2012 NDS SPp represents SPIB proposed values as provided in SPIB submittal to ALSC dated Sept 15, 2011 SP represents ALSC approved/new values with effective date of June 1, 2012 (2x4 No 2 and lower grades and smaller sizes), and all MSR/MEL grades © 2012 MiTek® All Rights Reserved mm Bill MiTek° •MiTek Engineering Reference Sheet: Mll-7473 rev. 09/04/2012 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1. 7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1. 8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber. 10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements. 12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 13. Top chords must be sheathed or purfins provided at spacing indicated on design. 14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 15. Connections not shown are the responsibility of others. 16. Do not cut or alter truss member or plate without prior approval of an engineer. 17. Install and load vertically unless indicated othewise. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. 19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone Is not sufficient. 20. Design assumes manufacture in accordance with ANSIAPI I Quality Criteria. 50.00' O 3 R p; co O to j r I TOTAL CURVE R=100.00' L=157.08' A=90.00'00 Q R= ° L= �_ 48 0 5 GINC. LOT 397 SIDEWALK OCCUPIED BST ❑ N 89'45'07" W 119.68' 0 4'X4' CONC. 28.18' A/C /PAD a PAVER DRIVE '00 , EXISTING ONE STORY CBS RESIDENCE / f RECLAIM r WATER VALVE \*110 �Ly \. Et- w 00' ° 35' ', )2'-12„ \c CAN :< BST❑ - _` F 84'2 50.00' 10.0C t w � o ooa ' 00a s SG' / 4.78'I/ �60 j15.97 8.00' 10.00' 1'X1' COLUMN COVERED PAVER ENTRY J J dp N f ut A0.00 CLEAN f.--OUT N 84'26 RECLAIM IWATER VALVE I OST-1 SET I.R.C. LB4286 ( TYP. ) EXISTING c^ \N EARTEN FORMS \ N• LOT 398 1 I 115.00' I E (R) I LOT 399 I OCCUPIED I CO. i I DatP 0���cl Thomas P. Kier`nari Date Signed Pr'ofessional,' Surveyor' &--Mapper Florida Certif'cate -,f4o: 6199 As —Built Survey/Tie—in for: Robert Britton LEGAL DESCRIPTION Being all of Lot 398, according to the plat of PORTOFINO SHORES —PHASE TWO as recorded in Plat Book 43, Page 33 of the Public Records of St. Lucie County, Florida. STREET ADDRESS 5812 Spring Lake Terrace LEGEND & ABBREVIATIONS A 'ice j GRAPHIC SCALE IN FEET CONC. DENOTES CONCRETE P.B. DENOTES PLAT BOOK P.C.P. DENOTES PERMANENT CONTROL POINT C.M. DENOTES CONCRETE MONUMENT (P) DENOTES PLAT DATA O.R. DENOTES OFFICIAL RECORDS BOOK C DENOTES CALCULATED FROM FIELD MEASUREMENTS IR & C DENOTES IRONROD & CAP DENOTES PROPERTY LINE PG. DENOTES PAGE R) DENOTES RADIAL COR. DENOTES CORNER ID DENOTES IDENTIFICATION NUMBER P.O.B. DENOTES POINT OF BEGINNING �) DENOTES FLOW LINE P.O.C. DENOTES POINT OF COMMENCEMENT TOB DENOTES TOP OF BANK I.P. DENOTES IRON PIPE TYP. DENOTES TYPICAL I.R. DENOTES IRON ROD FND. DENOTES FOUND U.E. DENOTES UTILITY EASEMENT L.B. DENOTES LICENSED BUSINESS P.I. DENOTES POINT OF INTERSECTION F.F.E. DENOTES FINISHED FLOOR ELEVATION W.M.T. DENOTES WATER MANAGEMENT TRACT ® DENOTES WATER METER DENOTES ELEVATION (TYPICAL) RIyy DENOTES RIGHT-OF-WAY OST DENOTES OPEN SPACE TRACT GENERAL NOTES 1. The bearings shown hereon are referenced to the centerline of Spring Lake Terrace having a bearing of S00'14'53"W, according to the plat of PORTOFINO SHORES —PHASE TWO as recorded in Plat Book 43, Page 33 of the Public Records of St. Lucie County, Florida. 2. All above ground fixed improvements, if any, have been located and shown hereon. 3. Underground utilities and utility services have not been located on this survey. 4. Flood Note: By graphic plotting only, this property is in Zone "X", according to the Flood Insurance Rate Map, Community Panal No. 120111CO070 J effective date of Revisions February 16, 2012. The exact designation can only be determined by an elevation certificate. 5. Reproductions of this map are not valid without the signature and original raised seal of a Florida Licensed Surveyor & Mapper. 6. Lands shown hereon were not abstracted by this office for rights —of —way, easements of record, ownership, abandonment's deed restrictions, or Murphy Act Deeds. 7. Additions or deletions to survey maps or reports by other than the signing party or parties is prohibited without written consent of the signing party or parties. 8. The last date of field work was September 08, 2006. Revision: 12-18-12 Add Formboard Tie—in, TPK Revision: 11-19-12 Update Survey, Add Site Plan, TPK Revision: 11-06-12 Update owner & Changed signing Surveyor, TPK Ilk, 2-1 S C, WARNING* NT ENGINERED THIS IS A PLAN E -CING: B) FOR SEE -FINAL ENGINEEEPJNG SHEETS FOR THE BACK CHARGES WILL NOT BE ACCEPTED UNLESS R COMPONENTS SEDEF DEFINED BYO WTCA 1 1995. THE ERECTION BRACING FOLLOW INSTRUCTIONS STRUCTURAL DATA, NUMBER OF GIRDER AND DES GN DEPARTMENT APPROVES THEM IN ADVANCE L BEARING POINTS MUST BE INSTALLED PRIOR TO DIAPHRAMS HAVE NOT BEEN ANALYZED BY DN THE BCSI-B1 SUMMARY SHEETS rRuss ALL HANGERS ARE SIMPSON STRONG -TIE UNLESS NSTALLING ANY TRUSSESI FAILURE TO DO SO MAY EAST CAOST TRUSS. 2) PERMANENT BRACING FOR THE STRUCTURE IS HE PLIES AND THE CONNECTION INFORMATION. OTHERWISE NOTED. INSTALL HANGERS ACCORDING RESULT IN DAMAGED TRUSSES AND WILL VOID ALL FOR ERECTION AND INSTALLATION OF TRUSSES RESPONSIBILITY OF OTHERS. CIUR DESIGN DEPARTMENT MUST APPROVE TO THE CURRENT SIMPSON STRONG -TIE CATALOG ARANTIES. FOLLOW INSTRUCTIONS ON THE BCSI-B1 SUMMARY 3) INSTALL WEB BRACING AS STATED ON SEALED ALTERATIONS AND/OR REPAIRS TO TRUSSES IN SHEETS AND SEALED ENGINEERED TRUSS DRAWINGS t` Py ` F. h E TE 5 TYP. END DETAIL xi) xA C, use Wt J:,it�� ULL�Jmlt ,il{��F r7�.7! rOMER: Robert Britton NAME:Robert Britton RESS:5812 Spring Lake Portofino Shores ICOUNTY:Ft. Pierce / St Lucie # 24208 FT=Oft" DWI NISTRATWE CODE 61G15S-31.003 (3) (c), EAST COAST TRUSS Is the "Truss Design Engineer" Trusses are designed in accordance with the Florida Building Code By approving this placement plan(s), signatured ywhere on this sheet, the customer or his presentifive acknowledges that this placement plan mplies with the structural intent of the project. The customer also acknowledges that this approva ithorizes FAST COAST TRUSS to manufacture ase trusses and deliver them to the project liceted on this drawing. The customer also acknowledges that he/she :cepts financial responsibility for any repair, igineering, and labor required due to errors other an those of FAST COAST TRUSS. gned: Date: bESIGN CRITERIA=C&C Hybrid MWFRS CCUPANCY CATEGORY=11 POSURE=C WF SPEED=170 WILDING TYPE= ENCLOSED EAN HEIGHT=I5.00it LOOR: DUR FACTOR = 1 .0 SF= TCLL-TCDL-BCLL-BCDL 40.0,10.0,0.0,5.0 POOR DUR FACTOR = 1 .25 SF= TCLL-TCDL-BCLL-BCDL 0.0,15.0,0.0,10.0 LOADS PER FBC & FRC *NON -CONCURRENT BC LL 10psf CONCURRENT BC STORAGE LL 20 psf DEFINITIONS MWF = MAIN WIND FORCE C&C = COMPONENTS AND CLADDING TOB = TOP OF BEARING TC = TOP CHORD BC = BOTTOM CHORD LL = LIVE LOAD DL = DEAD LOAD psi = POUNDS PER SQUARE FOOT # = POUNDS UPLIFT MUST BY-PASS FLOOR TRUSSES UNLESS SHOWN ON ENGINEERED TRUSS GIRDER/COLUMN LOADS MUST PASS FLOOR TRUSS UNLESS SHOWN ENGINEERED TRUSS DRAWING. RECOMMENDED ON FLOOR TRUSSES SPANNING 20=0.OR MORE ST BE SET WITH ASPREADER BAR. THE ZEADER BAR SHOULD BE AT LEAST 1/2 TO IN LENGTH AS THE SPAN OF THE TRUSS MG SET. :ER TO BCI-B1 FOR COMPLETE :CTION AND SAFETY PROCEDURES. SUPPORT ANY PLANT SHELVES r IL TRUSS PLACEMENT PLAN 50.00' ;O o 4 00 I--' a x r- to .u7 , a a vQ b . (n ' . 2 .00' .32 6 • � O TOTAL CURVE U) R=100.00'/AA L=157.08' `11a \ 5' CONC. SIDE WALK BST 1❑ 28.18' WATER VALVE .Ep � . /CAOTV" C►�� 50 00 R=100.00' 1=92.73'.. A--53707'48•" CONC VALLEY CURB LOT 397 OCCUPIED N 89'45'07n W 119.68' 0 4'X4' CONC. A C PAD j d M)/ �N W EXISTING ONE STORY CBS RESIDENCE / � o W N/ �tn0 QUO rn� i / z F t2/ //. i� UUd i14.78'�/ `,`�' / j15.97' i 8.00' 1,xi, COLUMN \ COVERED PAVER ENTRY io \ V N N CLEAN OUT N 84'26'13" E (K) RECLAIM IWATER VALVE L O T 399 CUPIED MIN, SETBACK BEQ. FRONT SIDES CNR SIDES � REAR TECH Boundar Robert i SurveyZSite Britton LEGAL DESCRIPTION OST-1 Being all of Lot 398, according to the plat of PORTOFINO SHORES —PHASE TWO as recorded in SET I.R.C. Plat Book 43, Page 33 of the Public Records of —LB4286 St. Lucie County, Florida. (TYP. ) STREET ADDRESS 5812 Spring Lake Terrace av PROPOSED �` N ADDITION \ N• 30_6 3 �6.00' LOT 398 1 1 I 115.00' I z 1* Z� � 19ZI Thomas P. Kiernan Date Signed Professional Surveyor & Mapper Florida Certificate No. 6199 I, LEGEND 8c ABBREVIATIONS plan for: CSC'-(R)�MC� [NOV 2 0 2012 � PUBLIC WORKS ST, LUCIE COUNTY FL 20 6—� 1� j GRAPHIC SCALE IN FEET CONC. DENOTES CONCRETE P.B. DENOTES PLAT BOOK P.C.P. DENOTES PERMANENT CONTROL POINT C.M. DENOTES CONCRETE MONUMENT (P) DENOTES PLAT DATA O.R. DENOTES OFFICIAL RECORDS BOOK C DENOTES CALCULATED FROM FIELD MEASUREMENTS IR & C DENOTES IRON ROD & CAP IC DENOTES PROPERTY LINE PG. DENOTES PAGE (R) DENOTES RADIAL COR. DENOTES CORNER ID DENOTES IDENTIFICATION NUMBER P.O.B. DENOTES POINT OF BEGINNING �) DENOTES FLOW LINE P.O.C. DENOTES POINT OF COMMENCEMENT TV DENOTES TOP OF BANK I.P. DENOTES IRON PIPE TYP. DENOTES TYPICAL I.R. DENOTES IRON ROD FND. DENOTES FOUND U.E. DENOTES UTILITY EASEMENT L.B. DENOTES LICENSED BUSINESS P.I. DENOTES POINT OF INTERSECTION F.F.E. DENOTES FINISHED FLOOR ELEVATION W.M.T. DENOTES WATER MANAGEMENT TRACT ® DENOTES WATER METER DENOTES ELEVATION (TYPICAL) R/yy DENOTES RIGHT-OF-WAY DST DENOTES OPEN SPACE TRACT GENERAL NOTES 1. The bearings shown hereon are referenced to the centerline of Spring Lake Terrace having a bearing of S00'14'53"W, according to the plat of PORTOFINO SHORES —PHASE TWO as recorded in Plat Book 43, Page 33 of the Public Records of St. Lucie County, Florida. 2. All above ground fixed improvements, if any, have been located and shown hereon. 3. Underground utilities and utility services have not been located on this survey. 4. Flood Note: By graphic plotting only, this property is in Zone "X", according to the Flood Insurance Rate Map, Community Ponal No. 120111CO070 J effective date of Revisions February 16, 2012. The exact designation can only be determined by an elevation certificate. 5. Reproductions of this map are not valid without the signature and original raised seal of a Florida Licensed Surveyor & Mapper. 6. Lands shown hereon were not abstracted by this office for rights —of —way, easements of record, ownership, abandonment's deed restrictions, or Murphy Act Deeds. 7. Additions or deletions to survey maps or reports by other than the signing party or parties is prohibited without written consent of the signing party or parties. 8. The last date of field work was September 08, 2006. Revision: 11-19-12 Update Survey, Add Site Plan, TPK Revision: 11-06-12 Update owner & Changed signing Surveyor, TPK THIS IS A PLACEMENT PLAN FOR ENGINRED EE995. CING: B) FOR SEE FINAL FNGI-N—EERING FOR THE BACK CHARGES WILL NOT BE ACCEPTED UNLESS WARNING* COMPONENTS AS DEFINED BY WTCA 1 THE ERECTION BRACING FOLLOW INSTRUCTIONS STRUCTURAL DATA, NUMBER OFSGIRDER AND DESIGN DEPARTMENT APPROVES THEM IN ADVANCER BEARING POINTS MUST BE INSTALLED PRIOR TO DIAPHRAMS HAVE NOT BEEN ANALYZED BY N THE BCSI-B1 SUMMARY SHEETS RUSS ALL HANGERS ARE SIMPSON STRONG -TIE UNLESS TALLING ANY TRUSSESI FAILURE TO DO SO MAY [ARANTIES. EAST CAOST TRUSS. 2) PERMANENT BRACING FOR THE STRUCTURE IS HE PLIES AND THE CONNECTION INFORMATION. OTHERWISE NOTED. INSTALL HANGERS ACCORDING SULT IN DAMAGED TRUSSES AND WILL VOID ALL FOR ERECTION AND INSTALLATION OF TRUSSES RESPONSIBILITY OF OTHERS. UR DESIGN DEPARTMENT MUST APPROVE TO THE CURRENT SIMPSON STRONG -TIE CATALOG FOLLOW INSTRUCTIONS ON THE BCSI-B1 SUMMARY 3) INSTALL WEB BRACING AS STATED ON SEALED ALTERATIONS AND/OR REPAIRS TO TRUSSES IN SHEETS AND SEALED ENGINEERED TRUSS DRAWINGSERING TRUSS DRAWINGS. ADVANCE, TYP. END DETAIL exaasa em�a ... e�tau r 0 r QY�2ti11;' �T`i'�'�it3G—Y�17€11 `MAY: (7i'.L�166—'.a^�G JSTOMER: Robert Britton �- )B NAME:Robert Britton )DRESS:5812 Spring Lake Portofino Shores TY/COUNTY:Ft. Pierce / St Lucie )B # 24206 )B # FT=Oft' DMINISTRATIVE CODE 61G15S-31.003 (3) (cN EAST COAST TRUSS Is the "Truss Design Engineer" Trusses are designed In accordance with the Florida Building Code By approving this placement plan(s), signatured nywhere on this sheet, the customer or his A ?presentitive acknowledges that this placement plan omplies with the structural intent of the project. t .The customer also acknowledges that this approval uthorizes EAST COAST TRUSS to manufacture , iese trusses and deliver them to the project t idicated on this drawing. r The customer also acknowledges that helshe ccepts financial responsibility for any repair, t ngineering, and labor required due to errors other ian those of EAST COAST TRUSS. t Iigned: Date: 4z LL W ' DE = FBC 2010Tf P12007 ASCE 7-10 )ESIGN CRITERIA=C&C Hybrid MWFRS a )CCUPANCY CATEGORY= II XPOSURE= C rq 4WF SPEED=170 rn IUILDING TYPE= ENCLOSED W 1EAN HEIGHT=I5.00ft z 1 D 'LOOR: DUR FACTOR = .0 to ISF= TCLL-TCDL-BCLL-BCDL 40.0,10.0,0.0,5.0 tOOF: DUR FACTOR = 1 .25 w ISF= TCLL-TCDL-BCLL-BCDL 30.0,15.0,0.0,10.0 W U) o LOADS PER FBC & FRC 'NON -CONCURRENT BC LL 10psf z O CONCURRENT BC STORAGE LL 20 psf DEFINITIONS MWF = MAIN WIND FORCE C&C = COMPONENTS AND CLADDING TOB = TOP OF BEARING TC = TOP CHORD BC = BOTTOM CHORD LL = LIVE LOAD } DL = DEAD LOAD psf = POUNDS PER SQUARE FOOT O # = POUNDS U UPLIFT MUST BY-PASS FLOOR TRUSSES UNLESS SHOWN ON ENGINEERED TRUSS J DRAWING. Q ALL GIRDER/COLUMN LOADS MUST BY-PASS FLOOR TRUSS UNLESS SHOWN O ON ENGINEERED TRUSS DRAWING. a 6 STRONG aACX BRACING, 100I RECOMMENDED ON FLOOR TRUSSES (Z SPANNING 20'-0' OR MORE Q UST BE SET WITH A SPREADER BAR. THE PREADER BAR SHOULD BE AT LEAST 1/2 TO 2/3 IN LENGTH AS THE SPAN OF THE TRUSS EING SET. REFER TO BCI-Bt FOR COMPLETE RECTION AND SAFETY PROCEDURES. ALL BEAMS BY BUILDER 4" NOTE. TRUSSES DO NOT SUPPORT ANY PLANT SHELVES r TRUSS PLACEMENT PLAN