Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSDate: l I 1 L9 t 1-/-4 Fee Due: O 1 1 Receipt# ) rmit # d,w IIaIy� ws.k. Planning & Development Services Building & Code Regulations Division 2300 Virginia Ave. Fort Pierce, FL 34982 (772)462-1553 SC St � yNEo County SPECIALTY PERMIT APPLICATION ❑ Electrical ❑ Plumbing G HVAC ❑ Fence ❑ Shed ❑ Demolition ❑ Gas ❑ Siding Seepage 2 for instructions and additional paperwork required for specialty permits 1. Location/Site Address: ?p0 2. Parcel ID Number: a 3 a ir.; �-:', Only Section Township Range Map Page Zoning land Use Initials 3. Complete Description of Project or Work: L,I'�(e Fo& 6,We- 4 �G Chaff c �Jf .S /0N If�'a."1 k7 Coo /D 1/. W MlleT / %O �¢-e� 4. Owners Information 5. Contractors Information Name: A011 /�QJous)C FL Reg/Cert #: C�iF/ S/ 79 Address: 71`03 J�/G,/1 y�,� �,4,4fCry/L County Cert#: e�yloa City: �;s{.. L Ucf'L State: �G. _ Business Name: 5L4&;G0'e %�Ltj, A) of A/G �i� c . Zip: 3ylq6G Phone: ?i�,aY�-/09� Phone: 721-yG7-WO Fax: �%�, y/ip- ��?/� 6. Value of Construction: $ C aa0 of OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in compliance with all applicable laws regal ng construction and zoning. a PRINT OWNER OR CONTRACTOR NAME I NATURE OF OWNER OR CONTRACTOR STATE OF FLORIDA, COUNTY OF ACKNOWLEDGED RE 1vIE- S DAY OF © , 20, BY WHO IS PER ONALLY KNOWN TO ME OR WHO HAS PRODUCED 1 ,, AS IDENTIFICATIO . A% LA HUFF _.: SI ATURE O OTARY TYPE OR RINT N ME OF NOTARY '•o ` MEXP EXPIRES: April k 083530 •••••. 12, 2015 Rf,„°t•' Bonded Thru Notary Public Underwriters COMMISSION NUMBER NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. EXEMPT: A/C -HEAT REPLACEMENT WITH CONTRACT UNDER S7500.00 Revised 04/262010 - - Wrightsoft Project Summary Entire House Project Inf• • For: GAIL MC DOUGLE A�_ .• >, � '` 7903 PLANTATION LAKES DR, ST laJCIE,�F Notes: Job: GAIL MC DOUGLE Date: Nov 05, 2012 By: ST LUCIE AIR Weather: West Palm Beach Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 48 °F Inside db 70 °F Design TD 22 'F Heating Summary Structure 18745 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 18745 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 Heating Cooling Area (ftz) 2652 2652 Volume (ft') 23868 23868 Air changes/hour 0.32 0.16 Equiv. AVF (cfm) 127 64 Heating Equipment Summary Make Trade Model AHRI ref no.n/a Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 0 Btuh 18745 Btuh 9 'F 1917 cfm 0.102 cfm/Btuh 0 in H2O Outside db 95 'F Inside db 75 °F Design TD 20 °F Daily range L Relative humidity 50 % Moisture difference 69 gr/lb Sensible Cooling Equipment Load Sizing Structure 39317 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 1.00 Equipment sensible load 39121 Btuh Latent Cooling Equipment Load Sizing Structure 16806 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Equipment latent load 16806 Btuh Equipment total load 55927 Btuh Req. total capacity at 0.70 SHR 4.7 ton Cooling Equipment Summary Make American Standard Trade ALLEGIANCE 16 Cond 4A7A606OE1 Coil *AM7AOC6OH51 AHRI ref no.4385265 Efficiency 13.0 EER, 17 SEER Sensible cooling 40250 Btuh Latent cooling 17250 Btuh Total cooling 57500 Btuh Actual air flow 1917 cfm Air flow factor 0.049 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.70 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. I1tSOft 2012-Nov-0512:57:28 W r� Right -Suite® Universal 2012 12.0.00 RSU15842 Page 1 CAUsers\Rich & Darlene\Desktop\M J Projects\GAIL MC DOUGLE.rup Calc = MJ8 Front Door faces: N .41c- This combination qualifies for a Federal Energy Efficiency Tax Credit when placed in service between Feb 17, 2009 and Dec 31, 2011. Certificate of Product Ratings AHRI Certified Reference Number: 4385265 Date: 11/5/2012 Product: Split System: Air -Cooled Condensing Unit, Coil with Blower Outdoor Unit Model Number: 4A7A606OE1 Indoor Unit Model Number: *AM7AOC6OH51 Manufacturer: AMERICAN STANDARD, INC. Trade/Brand name: ALLEGIANCE 16 Manufacturer responsible for the rating of this system combination is AMERICAN STANDARD, INC. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air -Conditioning and Air -Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): 57500 EER Rating (Cooling): 13.00 SEER Rating (Cooling): 17.00 Ratings followed by an asterisk (') indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION A "Imp, The information for the model cited on this certificate can be verified at www.ahridirectory.org, Air -Conditioning, Heating, click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on A. ■� a and Refrigeration Institute which the certificate was issued, which is listed above, and the Certificate No., which is listed below. ©2012 Air -Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129965971094192746 Property Appraiser - St.Lucie Count, Page 1 of 1 Gail S McDougle Record: 1 of 1 Property Identification Site Address: 7903 PLANTATION LAKES DR Sec/Town/Range: 22 :36S :39E Map ID: 33/22S Zoning: RS-2 PROPERTY RECORD CARD <<Prev Next » Spec.Assmnt Taxes Exemptions Permits Home Print ,��,UCIE CO ParcellD: 3321-801-0066-000-4 Account #: 35883 �P Use Type: SF Res �•j City/Cnty: St Lucie County Ownership and Mailing Legal Description Owner: Gail S McDougle RESERVE PLANTATION -PHASE I- LOT 66 (OR 3250-1673) Address: 7903 Plantation Lakes Dr Port St Lucie FL 34986-3005 Sales Information Assessment 2012 TRIM Total Land and Building Date Price Code Deed Book/Page 2012 TRIM: 255900 Land Value: 55100 Acres: 0.83 11/29/2010 270000 0001 WD 3250 / 1673 Assessed: 255900 Building Value: 200800 4/15/2002 300000 00 WD 1530 / 2286 Ag.Credit: 0 Finished Area: 2626 SgFt 11/1/1986 34500 00 CV 0521 / 1393 Exempt: 50000 Taxable: 205900 Taxes: 4359.89 BUILDING INFORMATION w Exterior Features View: RoofCover: TN - Metal RoofStruct: HP ExtType: HA- - HA- YearBlt: 1987 Frame: Grade: A- - A- EffYrBlt: 1987 PrimeWall: FS - Frm Stucco StoryHght: 0010 - 1 Story No.Units: 1 SecWall: Interior Features BedRooms: 3 Electric: MX - MAXIMUM PrmintWall: DW - Drywall FullBath: 2 HeatType: FHA - FrcdHotAir AvgHUFI: 1/213ath: 1 HeatFuel: ELEC - Electric Prm.Flors: CT - Tile -Ceramic %A/C: 100 %Heated: 100 %Sprinkled: 0 Special Features and Yard Items Land Information Type Y/S Qty. Units Qual. Cond. YrBlt. No. Use Type Type Measure Depth SWAV - RES POOL AVG Y 1 450 AV AV 1987 1 0100-SF Res GFC -Front Ft 181.09 200 PA01 - POOL DK-AVG Y 1 765 AV AV 1987 ENC2 - POOL ENC-AVG Y 1 1215 AV AV 1987 PHTR - POOL HEATER Y 1 1 AV AV 1987 DWC - Driv-Concret Y 1 900 AV AV 1987 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED http://www.paslc.org/paslc/prc.asp?prclid=332180100660004 11 /6/2012