Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSOFFICE USE O . ,Y: Date: Fee Due: Receip Permit # a 1 PLANNING & DEVELOPMENT SERVICES ®► BUILDING & CODE REGULATION DIVISION SCANNED • . 2300 Virginia Avenue BY Ft. Pierce, FL 34982-5652 St. Lucie CO 772-462-1553 untY APPLICATION FOR ALUMINUM STRUCTURES PERMIT ALL INFO MUST BE COMPLETE & FILLED IN TO BE ACCEPTED PROJECT INFORMATION 1. LOCATION/SITE ADDRESS: 17 San Felipe Fensterer 2. PROJECT NAMECotintry C u evillage SITE PLAN NAME: 3. PROPERTY TAX ID #: - - - % 3 01— / j f — 4. LEGAL DESCRIPTION (attach extra sheets if necessary): East .'—, of Section 1, Township 34S, Range 39 E less N 1069.59' lying N&W of Turnpike Feeder Rd. 5. PLAT BK PAGE BLOCK LOT 6. PARCEL SIZE: ACRES/SQ FT. LOT DIMENSIONS 7. SETBACKS (ACTUAL) FRONT: BACK: RIGHT SIDE: LEFT SIDE: S. TYPE OF STRUCTURE (CHECK ALL APPROPRIATE BOXES FOR EACH AND EVERY TYPE OF STRUCTURE) *Infill under existinq truss roof** TYPE OF CONSTRUCTION N = New A = Addition R = Rebuild SG = Slab on Grade SR = Raised Slab WD = Wood Deck DIMENSIONS SQUARE FEET OF CONSTRUCTION SCREEN ROOM N SG ❑ NEW EXISTING 10 ' X 2 0' 2 0 0 ❑ CARPORT/PATIO ROOF ❑ NEW ❑ EXISTING X ❑ HABITABLE GLASS ROOM ❑ NEW ❑ EXISTING X ❑ CAT 1, 2 OR 3 SUNROOM ❑ NEW ❑ EXISTING X ❑ ALUMINUM COMP. SHED ❑ NEW ❑ EXISTING X ❑ POOL ENCLOSURE ❑ NEW ❑ EXISTING X ❑ M H ROOF OVER ❑ NEW ❑ EXISTING X ❑ ROOF SYSTEM OVER EXISTING ACCESSORY STRUCTURE ❑ NEW ❑ EXISTING X ❑ OTHER: ❑ NEW ❑ EXISTING X ❑ ALUM POOL FENCE Linear feet TOTAL SQUARE FOOTAGE OF CONSTRUCTION 2 0 0 9. VALUE OF CONSTRUCTION: $ 2, 4 2 5. 0 0 The value of construction is used to determine the amount of permit fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction activities. If the value is $2500 or more, a RECORDED Notice of Commencement must be submitted PRIOR TO FIRST INSPECTION. SLCCDV Form No.: 001-02 Rev 0412&2010 OWNER INFORMATION NAME:' Carol Fensterer ADDRESS: 17 San Felipe CITY: Fort Pierce STATE: FL ZIP 34951 PHONE (DAYTIME): (_, 5 9 5 -14 5 7 EMAIL: FILL IN NAME AND ADDRESS BELOW IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE: FEE SIMPLE TITLEHOLDER: ADDRESS: CITY: STATE: ZIP PHONE (DAYTIME): ( j CONTRACTOR INFORMATION STATE OF FLORIDA REG./CERT #: S C C 13115 0 5 8 6 ST. LUCIE COUNTY CERT #: 2 5 5 8 4 BUSINESS NAME: Master Craft Aluminum Products QUALIFIER'S NAME: Jef f Jackman ADDRESS: 1634 SE Niemeyer Circle CITY: Port St. Lucie STATE: FL ZIP 34952 PHONE (DAYTUvIE): C--) 335-1177 FAX NO. 335-0860 email: mastercraftaluminum ARCHITECT/ENGINEER: n / a @gmail.com ADDRESS: CITY: STATE: ZIP PHONE (DAYTM): �) NOTE: IF APPLICABLE, SUBCONTRACTOR AGREEMENTS MUST BE ATTACHED TO APPLICATION FOR ROOFING, ELECTRIC, PLUMBING, AND HVAC ZONING REQUIREMENTS All such structures will be subject to the requirements of the ST. LUCIE COUNTY LAND DEVELOPMENT CODE. ❑ 2 scaled plot plans showing lot size, dimensions of existing host structure, and proposed aluminum addition. All setbacks including front, side, rear and distance between adjacent property structures in MH Parks shall be indicated on the plot plan. ❑ 2 sets of color photos for all storm damaged areas to be reconstructed. One picture must include house address number f inspection verification. ( not required for construction unrelated to storms) or OFFICE USE ONLY SECTION TOWNSHIP RANGE ZONING LAND USE LOT CV _ODE T I I BIMS FEE I$ L =NUSCFEES BUILDING & ZONING REVIEW FRONT PLANS 7 COUNTER ZONING SUPERVISOR EXAMINER DATE MAP NO. Permits ITOTAL FEES I $ VALUE OF CONSTRUC VEGETATION USING ICC TABLE rNnTTAr.c PLAN RE V,EW SPECIFICATION CHECKLIST PLEASE PROVIDE ONE OF THE FOLLOWING 0 ❑ 2 Sets of Detailed Plans: Dated, Signed & Sealed by an Engineer or Architect holding a Florida State professional license. ❑ 2 Sets of Detailed Plans: Designed in accordance with the AAF Guide to Aluminum Construction in High Wind Areas. ❑ 2 Sets of Detailed Plans: Designed in accordance with any Approved Manual per fs-489.113. (1) ANY PLANS SUBMITTED WITHOUT COMPLYING WITH THE FOLLOWING SHALL BE RETURNED WITHOUT APPROVAL. ALL PLANS MUST BE IN INK AND ANY NOTATIONS IN PENCIL WILL NOT BE CONSIDERED A PART OF A SUBMISSION. • All plans must be legible and must be designed in Architect's Scale on pages which are 81/2" x I , or larger. • All relevant tables & details, if using a manual, must be properly highlighted and must match design checklists & drawings. • The plan view must include all dimensions; the location of the host structure and all materials must be sized and identified thereon. • All elevations must be shown, including 40' wall detail, dimensions and all material must be sized and identified. • All primary and secondary carrier beams, spans, spacing, gauges must be shown [Example: 2" x 8" x .072"]. • All methods of fastening or other details which are relevant to the design must be identified on the Plans. • All upright column heights, sizes, spacing and gauges must be shown as follows: [Example: 3" x 3" x .050"]. • All chair -rails, roof purlins, girts, channels, knee -bracing, k-bracing, cable bracing or any other required component must be sized and identified. • All ridge beams and super gutter or fascia attachments must be identified. • All roof pans or composite panels, with gauges and spans, must be sized and identified. • All footing, slab and ISO pier designs must be on the plans, per the Architect / Engineer's plans & specifications. • All light metal alloys which are utilized shall be designed in conformity with the Florida Building Code of 2007, Chapter 20, including 2006 revisions. • Barrier railings, if utilized, shall have all materials, fasteners and height specified and shall have self -closing, self - catching gates with picket spacing. (II) SITE CONSTRUCTED SHEDS, HAVING ANYALUMINUM COMPONENT, SHALL MEET ALL OF THE ABOVE REQUIREMENTS AND THE FOLLOWING ADDITIONAL ITEMS: (A) 2 copies of the current product approval [i.e. N.O.A. or State of Florida approval] with the proposed "opening" or cladding component highlighted and with fasteners and design pressures, per FBC 1714, clearly identified. (B) 2 electric schematics, in accordance with the N.E.C., if applicable. (C) Design pressures, per ASCE-7, identified on the openings of all Plans. (III) HABITABLE ROOMS/ADDITIONS DESIGNS SHALL MEET ALL OF THE ABOVE REQUIREMENTS, EXCEPT AAMA SPECIFICATIONS, AND CHAPTER 13 OF THE FLORIDA BUILDING CODE. (IV) SUNROOMS (as defined in R202 and FBC 2002.6) MAY BE CONSTRUCTED, SO LONG AS THEY MEET ALL OF THE ABOVE REQUIREMENTS AND MUST BE IN STRICT COMPLIANCE WITH AAMA/NPEA/NSA2100.02 AND MEET THE FOLLOWING ADDITIONAL ITEMS: (1) The designer or engineer will state on all Plans, which Category of Design P.1.21 will be used, inclusive of the definition. (2) If designing a Category 4 or Category 5 structure, as defined in the current Edition of 3.1.2.4 and 3.1.2.5, proper energy calculations and long form equipment sizing calculations shall be required, pursuant to Chapter 13 of the current State of Florida Building Code. (V) MOBILE HOMES (FAC 15C-2.0081 - FAC 15C-2.0072): ALL STRUCTURES ADJACENT TO OR NEW ROOF SYSTEMS (Pan or Composite) OVER EXISTING ADJACENT STRUCTURES TO A MOBILE HOME SHALL REQUIRE: (a) A 4'n wall or a current, signed original manufacturer's attachment approval letter which includes the model number, serial number and current owner's name and street address. (b) That the complete guide to H.U.D. specifications be strictly adhered to. (c) A Certified Florida Engineer may design the manner of attachment of the proposed structure to the host house but shall assume full responsibility for both structures' integrity by site specific documentation. CERTIFICATION: This application is hereby made in order to obtain a permit to do the work and installations as indicated, and to obtain m certificate of capacity, if applicable, for the permitted work. NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE TO APPLICANT: IN THE EVENT IT IS NOT YOUR RIGHT TITLE OR INTEREST THAT IS SUBJECT TO ATTACHMENT, THE APPLICANT DOES HEREBY MAKE A GOOD FAITH PROMISE TO DELIVER A COPY OF THE ATTACHED CONSTRUCTION LIEN LAW NOTICE TO THE PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT, AND DOES SO AS A CONDITION PRECEDENT TO THIS PERMIT 1. If utilizing the AAF Guide to Aluminum Construction in High Wind Zones, I the Contractor/Owner Builder hereby certify that the components being used, fasteners type and fastening pattern meet all the requirements for the designated wind zones established by the county and take full responsibility for complying with the submitted design of the structure being permitted. 2. I further certify that all the foregoing information is accurate, that no work or installation has commenced prior to the issuance of a permit and that all work shall be performed in compliance with all applicable laws regulating construction and zoning in this jurisdiction. I understand that separate permits may be required for ELECTRICAL, and HVAC, etc., not otherwise included with this building permit application. 3. I , the Contractor / Owner Builder, have verified that the existing foundation meets the requirements of the Engineer of exceed the footprint of the structure that was in existence prior to Record and is in adequate condition to withstand the uplift and weight of the aluminum structure and said structure will not removal by the storms. 0 0 CTOR SIGNATURE STAYF FLORIDA COUNTY OF _ St Lu ; The foregoing instrument was acknowledged before me me this 1 s tday of November 20 12 by Jeff Jackman who is personally known X to me, or who has produced as identification. SHERYL D. MOORE lwlNOTARY PUBLIC "T(19MI9F FLORIDA Signature OtNookysye!rin1# EL 1 A6461 APIMs 1/16/2016 IMPORTANT NOTICES: 4CT*1GN-ATURE STATE OF FLORIDA COUNTY OF S t- , T,,, The foregoing instrument was acknowledged before me me this 1st day of November by Jeff Jackman 2012 who is personally known X to me, or who has produced as identification. SHERYL D. MOORE JPNOTARY PUBLIC Signature ofATE OF(4IDA Corrtriitt EE156461 Uplrec 111512016 • TWO (2) SIGNATURES ARE REQUIRED. EACH SIGNATURE MUST BE NOTARIZED. IF APPLYING FOR THIS BUILDING PERMIT AS AN OWNER/BUILDER, THE OWNER MUST PERSONALLY APPEAR, IN THE OFFICE LISTED ON THE FRONT OF THE APPLICATION, TO SIGN THIS APPLICATIONS: THE OWNER/BLDR AFFIDAVIT. • ALL SIGNATURES ON APPLICATION SUBMITTED SHALL BE ORIGINAL, SIGNED IN INK. COPIES, FAXES, OR STAMPED REPRODUCTIONS ARE PROHIBITED. • WHEN A PERMIT IS AVAILIBLE FOR ISSUANCE BUT IS NOT PICKED UP WITHIN THIRTY (30) DAYS AFTER NOTIFICATION OF AVAILIBILITY, IT WILL BE VOIDED. IF THE APPLICATION IS RESUBMITTED, AN ADDITIONAL FEE WILL BE CHARGED. 11/05/2012 11:56 7728787656 -'�- WYNNE BUILDING CORP ar (7 1 0 V4, 1 N 0 3 q, I. Z. st Ow 'A� Vol, 72 lie 4 !S --X .5% PAGE 01/01 EINZ I "'Nis bfK! s c. PIN 5 4zi - 00 M -11, Property Appraiser - St.Lucie Cour'-, FL Page 1 of 1 PROPERTY RECORD CARD Wynne Building Corp Record: 1 of 7 <<Prev Next» Spec.Assmnt Taxes Exemptions Permits Home Print Property Identification ��uCiE CO Site Address: 6487 SPANISH LAKES BV ParceIID: 1306-111-0001-000-0 Gy � Sec/Town/Range: 06 :34S :39E Account #: 4031 Map ID: 13/06N Use Type: PRKG/MOBILE Zoning: PUD City/Cnty: St Lucie County Ownership and Mailing Legal Description Owner: Wynne Building Corp 06/07 34 39 ALL THAT PART LYG NELY OF 1-95-LESS SPANISH Address: 12804 SW 122nd Ave LAKES FAIRWAYS (PB 35-5) AND LESS THAT PART Miami FL 33186-6203 More... Sales Information Assessment 2012 TRIM Total Land and Building Date Price Code Deed Book/Page 2012 TRIM: 21833200 Land Value: 7867500 Acres: 326.04 5/1/1986 1315000 02 CV 0502 / 0947 Assessed: 21833200 Building Value: 13965700 1/1/1984 674200 02 CV 0422 / 2136 Ag.Credit: 0 Finished Area: 25655 SgFt Exempt: 0 Taxable: 21833200 Taxes: 441714.01 BUILDING INFORMATION Exterior Features View: RoofCover: - ExtType: MHPK - MH Parks YearBlt: 1990 Grade: Y_C - Commer C EffYrBit: 1990 StoryHght: 0010 - 1 Story No.Units: 1049 Interior Features BedRooms: 1450 Electric: FullBath: 0 HeatType: 1/2Bath: 0 HeatFuel: %A/C: 0 %Heated: Special Features and Yard Items Type Y/S Qty. Units Qual. Cond. YrBlt. CSAV - COM POOL AVG Y 1 2720 AV AV 1990 PA01 - POOL DK-AVG Y 1 6324 AV AV 1990 ASP2 - ASP2 LOW Y 1 544000 AV AV 1990 CNC2 - CONCRETE LOW Y 1 25752 AV AV 1990 CURB - CEMENT CURB Y 1 700 AV AV 1990 FEW - CHAINLINK 10 Y 1 343 AV AV 1990 FEN4 - CHAINLINK 4' Y 1 95 AV AV 1990 RoofStruct: Frame: PrimeWall: SecWall: PrmintWall: AvgHUFI: - Prm.Fiors: 0 %Sprinkled: Land Information No. Use Type Type 1 2800-PRKG/MOBILE 191 -Site 0 Measure Depth 1049 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED. http://www.paslc.org/paslc/prc.asp?prclid=130611100010000 11 /6/2012