HomeMy WebLinkAboutSUBMITTED PAPERSW 1.
PLANNING & DEVELOPMENT SERVICES
BUILDING & CODE REGULATION DIVISION
2300 Virginia Avenue
Ft Pierce, FL 34982-5652
772-462-1553
APPLICATION FOR ALUMINUM STRUCTURES PERMIT
ALL INFO MUST BE COMPLETE & FILLED IN TO BE ACCMEp E®
PROJECT INFORMATION BY
Sk. Lucie County
L LOCATION/SITE ADDRESS:_ . 6690 Lila Court (Kelly)
2. PROJECTNAME:Spanish Lakes SITE PLAN NAME:
3. PROPERTY TAX ID#: 1306-1> 1 -nnni -onn/n
4.
LEGAL DESCRIPTION (attach extra sheets if necessary):
5.
6.
7.
8.
PLAT BK PAGE BLOCK LOT
PARCEL SIZE: ACRES/SQ FT. LOT DEWENSIONS 6 0 ' x 110 ' x 2 5 ' x 4 7.8 9 ' x 8 0 '
SETBACKS (ACTUAL) FRONT: 2 9 BACK: 15 RIGHT SIDE: 7 ' LEFT SIDE: 2 0 '
TYPE OF STRUCTURE (CHECK ALL APPROPRIATE BOXES FOR EACH AND EVERY TYPE OF STRUCTURE)
TYPE OF CONSTRUCTION
N = New
- A = Addition
R = Rebuild
SG = Slab on Grade
SR = Raised Slab
WD =.Wood Deck
DMIENSIONS
SQUARE FEET OF
CONSTRUCTION
❑
SCREEN ROOM
❑ NEW ❑
. EXISTING
X
❑
CARPORT/PATIO ROOF '
❑ NEW ❑
EXISTING
X
❑
•HABITABLE GLASS ROOM
❑ NEW ❑
EXISTING
X
®
CAT 1, 2 O 3 UNROOM
N
SG El NEW U
EXISTING
9' X -20'
180
❑:
ALUMINUM COMP_ SHED
❑ NEW ❑
. EXISTING
X
POOL ENCLOSURE
❑ NEW ❑
EXISTING
X
❑
M H ROOF OVER
❑ NEW ❑
EXISTING
X
❑ ROOF SYSTEM OVER
EXISTING ACCESSORY STRUCTURE
❑ NEW ❑
EXISTING
X
❑
OTHER:
❑ NEW ❑
EXISTING
X
❑
ALUM POOL FENCE
Linear feet
TOTAL SQUARE FOOTAGE OF CONSTRUCTION
180
9. VALUE OF CONSTRUCTION: $ 7, 0 0 0. 0 0
The value of construction is used to determine the amount of permit fees to be assessed. St. Lucie County'reserves the right to
question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with
similar types of construction.activities. If the value is. $2500 or more, a RECORDED Notice of Commencement must be submitted
PRIOR TO FIRST INSPECTION.
SLCCDV Form No.: 001-02 Reat0412612010
r
OWNER INFORMATION _
NAME: Sallyann Kelly
ADDRESS: 6690 Lila Court
------------
CITY: Fort Pierce STATE: Fr. ZIP
34AS1
PHONE (DAYTIME):. (_) 519 — 3 4 0 6 - EMAIL:
FILL IN NAME AND ADDRESS BELOW IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM
THE OWNER LISTED ABOVE:
FEE SIMPLE TITLEHOLDER:
ADDRESS:
CITY: STATE: ZIP'
PHONE.(DAYTIME): ( )
CONTRACTOR INFORMATION
STATE OF TLORIDA REG./CERT #: S CC 13115 0 5 8 6 ST. LUCIE COUNTY CERT #: 5 5 R 4
BUSINESSNAME: Master Craft Aluminum Products.
QUALIFIER'S NAME: Jeff Jackman
ADDRESS: 1634 SE Nieme er Circle
.CITY: Port St. Lucie STATE: FL ZIP � . 34952
PHONE (DAYTIME):
ARCHITECTIENGINEER:
ADDRESS:
CITY:
( ) 335-1177 FAXNO. 335-086,0
STATE:
email: mastercraftaluminum
@gmail.com
PHONE (DAYTIME):
NOTE: IF APPLICABLE, SUBCONTRACTOR AGREEMENTS MUST BE ATTACHED TO APPLICATION FOR ROOFING, ELECTRIC, PLUMBING,
AND HVAC
ZONING REQUIREMENTS
All such structures will be subjed.to the requirements of the ST. LUClE COUNTY LAND DEVELOPMENT CODE.
❑ 2 scaled'plot plans showing lot size, dimensions of existing host structure,and proposed aluminum addition. Allsetbacks
including front, side; rear and distance between adjacent property structures in MH Parks shallbe indicated on the plot plan.
❑ 2 sets of color photos for all storm damaged areas .to be reconstructed. One picture must include -house address number for
inspection verification. ( not required. for'construction unrelated to storms)
SECTION . I (.TOWNSHIP
ZONING I I LAND USE
_ODE REPORT I BIMS FEE. js,
BUILDING & ZONING REVIEW
.OFFICE USE. ONLY .
4MIRANGE.
LOT CVG
SC FEES
REVIEW COUNTER I ZONING I SUPERVISOR I EXAA014ER
VEGETATION
MAP NO.
Permits. ! ,e&e7VrC_
TOTAL FEES I
USING ICC TABLE
MTMA,T C
REVIEW SPECIFICATION -CHECKLIST'
PLEASE PROVIDE ONE OF THE FOLLOWING:
54 2 Sets of Detailed Plans:' Dated, Signed & Sealed by anEngineer or Architect holding a Florida State professional -license.
❑ . 2 Sets of Detailed Plans: Designed in accordance'with the AA'Guide to Aluminum Construction in High Wind Areas.
.❑ 2 Sets of Detailed P1ans:.Designed in accordance with any Approved Manual per,A-489.111.
(1) ANY PLANS SUBMITTED WITHOUT COMPLYING'WITH THETOLLOWING SHALL BE RETURNED WITHOUT
APPROVAL. ALL PLANS MUST BE KINK AND ANY NOTATIONS IN PENCIL WILL.NOT BE CONSIDERED. A PART OF
A SUBNIISSION.
• All plans must be legible and must be designed in Architect's Scale on pages. which.are 81/2" x I I" or. larger.
• All relevant tables & details, if using a manual, must be properly highlighted. and must match -design checklists &
drawings.
• , The plan view must include all dimensions; the.location of the host structure and all materials must be sized and
identified thereon.
• All elevations must be shown, including 4's wall detail, dimensions and all material must be sized and identified.
• All primary and secondary carrier beams, spans, spacing, gauges must be shown [Example: 2" x 8" x .072"].
• All methods of fastening or other details which are relevant to: the design must be identified on.the Plans.
• All upright column: heights, sizes; spacing and gauges must be shown as follows: [Example: 3" x 3" x .050"].
• All chair -rails, roof purlins, girts; channels, lmee-bracing, k-bracing, cable bracing, or any other required component
must be sized and identified. .
• All ridge beams and super gutter or fascia attachments must be identified.
• All roof pans or composite panels, with gauges and spans; must be sized and identified.
• All footing, slab and ISO pier designs must be on the plans, per the Architect / Engineer's plans & specifications.
• All light metal alloys which are utilized shall -be designed in* conformity with the Florida Building Code of 2007, Chapter
20, including 2006 revisions.*.
• Barrier railings; if utilized, shallhave all materials, fasteners and height specified.and shall have self -closing, self -
catching gates with picket spacing.
(H) SITE CONSTRUCTED SHEDS, HAVING ANYALUNDNUM COMPONENT, SHALL MEETALL OF THE ABOVE
REQUIREMENTS AND THE FOLLOWING ADDITIONAL ITEMS::
(A) 2 copies of the current product approval [i.e. N.O:A.,or State of Florida approval] with the, proposed "opening" or -cladding
component highlighted and with fasteners and design pressures, per FBC 1714, clearly identified.
(B) 2 electric schematics, in accordance with the. NX.C., if applicable.
(C) Design pressures, per ASCE-7,.identified on the openings of all Plans.
(III) HABITABLE ROOMS/ADDITIONS DESIGNS SHALL MEET ALL OF THE ABOVE REQUIREMENTS, EXCEPT AAMA
SPECIFICATIONS, AND CHAPTER 13 OF THE FLORIDA.BUILDING CODE.
(IV) SUNROOMS (as defined in R202 and FBC 2002.6) MAY CONSTRUCTED, SO LONG AS THEY MEET ALL OF THE
ABOVE. REQUIREMENTS AND MUST BE IN STRICT COMPLIANCE WITH AAMA/NPEA/NSA2100.112.AND MEET THE
FOLLOWING ADDITIONAL ITEMS:
(1), The designer or engineer will state on all Plans,. which Category of Design [3.1,2] will be used, 'inclusive of the definition.
(2) If designing a Category 4 or Category 5 structure, as defined -in the current Edition of-3.1.2.4 and.3.1.2.5, proper energy
calculations and long,form equipment sizing calculations shall be required, pursuant to Chapter 13 of the current State of
Florida Building Code..
(V) MOBILE HOMES ,(FAC 15C-2.008I - FAC 15C-2.0072):.ALL STRUCTURES ADJACENT TO OR NEW ROOF SYSTEMS
(Pan -or Composite) OVER EXISTING ADJACENT STRUCTURES TO: A MOBILE HOME`SHALL REQUIRE:
(a) A 4" wall or a current, signed original manufacturer's attachment approval letter which includes the model number, serial
number and current owner's name and street address..
(b) That the complete guide to H.U.D. specifications be strictly adhered to.
(c) A Certified Florida Engineer may design the manner of attachment of the proposed structure to the host house but shall
assume full responsibility for both structures' integrity bysite specific documentation..
CERTMCATION:
This °application is hereby made in -order to obtain a permit to do the work and in as indicated, and to obtain a
certificate of capacity, if applicable, for the permitted work.
NOTICE TO OWNER: FAILURE TO. RECORD A NOTICE OF COMMENCEMENT . MAY RESULT IN YOU
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO
OBTAINFINANCING,' CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF.COMMENCEMENT.
NOTICE TO APPLICANT: IN THE EVENT IT IS .NOT' YOUR RIGHT TITLE OR' INTEREST' THAT IS SUBJECT TO
ATTACHMENT, THE APPLICANT -DOES' HEREBY MAKE A GOOD FAITH PROMISE TO
DELIVER A COPY- OF THE ATTACHED CONSTRUCTION LIEN LAW NOTICE TO THE
PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT, AND "DOES. SO AS A
CONDITION PRECEDENT TO THIS PERMIT
1. If utilizing the .AAF Guide to Aluminum Construction in High Wind Zones, I the Contractor/Owner Builder hereby certify -
that the components being)ised; fasteners type and: fastening pattern meet all the requirements for the designated wind
zones established by4he county and take full responsibility for complying with the submitted design.of the structure being
permitted. '
2. I further certify that,all the foregoing information is accurate, that no.work or installation, has. commenced prior to the
issuance of a permit and that all work -shall be performed in compliance with all applicable laws regulating construction and
zoning in this jurisdiction -I understand that - separate permits may. be required for. ELECTRICAL, and HVAC, etc., not
otherwise included with this building permit application.
3. I , the Contractor / Owner Builder, have verified that the existing foundation meets the requirements of the. Engineer of
Record and is inadequate condition.to withstand the uplift and weight of the aluminum structure and said structure will not
exceed the footprint of the structure that was in existence prior to removal by the storms.
0 - CTOR SIGNATURE
.STAZ ORIDA
COUNTY OF. St. Lucie
The foregoing instrument was acknowledged before me
me this 17 day of October 20 12
by Jeff Jackman -
who is personally known X . to or who has.
produced
CO SIGNATURE
STATE FLORIDA
COUNTY OF_SL, . Lucie
The foregoing instrument was acknowledged before me
metals 17 dayof October ,2012
by Jeff .Jackman
who is personally known x to me, -or who has
produced
as identification. SHEaYL D..MOORE
NOTARY PUBLIC as identification.
STATE OF SHERYL D. MOORE
# F FLORIDAFLO I a NOTARY. PUBLIC
�^ STAT gla�,.ORIDA
Signature ofNotary eXpIrHS 1/1512016. SignatureioaE
Comm EE115"61
IMPORTANT NOTICES: set EkplMs 111 W2016
TWO (2). SIGNATURES ARE REQUIRED; EACH SIGNATURE MUST BE NOTARIZED.. IF APPLYING FOR THIS
BUILDING PERMIT AS AN OWNER/BUILDER, THE OWNER MUST PERSONALLY APPEAR,, IN THE OFFICE
LISTED, ON THE,,FRON . OF THE APPLICATION, TO SIGN THIS APPLICATION & THE OWNER/BLDR
AFFIDAVIT. .
ALL SIGNATURES ON APPLICATION SUBMITTED SHALL BE ORIGINAL, SIGNED IN INK. COPIES, -TAXES, OR
STAMPED REPRODUCTIONS ARE PROHIBITED.
WHEN A PERMIT IS AVAILIBLE FOR ISSUANCE BUT IS NOT PICKED UP WITHIN THIRTY (30) DAYSAFTER
NOTIFICATION OF AVAILIBILTTY, IT WILL BE VOIDED."IF THE APPLICATION IS RESUBMITTED, .AN
ADDITIONAL FEE `WILL BE CHARGED.
�Z
-1 NOTICE OF G-OWENCEMENT'r
Permit No. 1' 001 Tax Folio No.1306-111=0001-000/0
State of Florida County of St. Lucie
The undersigned hereby gives notice that improvement willbe made to certain real property, and in.accordance with Chapter 713,
Florida Statutes,
.the following information is provided:inthis.Notice of Commencement.
Legal Description of Property: (and street address if available):
6690 Lila Court - SLFWY
General description of improvement: Convert Lanai to Catagory III sunroom
- X0MNL
m;uFPAO
o o M z m
Owner information or Lessee information if the Lessee contracted for the improvement:.
G.)i A N n In
Name Sallyann -Kelly
N rn
Address 6690 T.i 1 a Court,Fort Pip -rep, FT, 34991
0 �C s
Interest in property:
Noz-
o o
Name and address of fee simple titleholder (if different from Owner listed above):
1-1
M N m
n/a
Nj
�N O
contractor's Name. Master Craft. Aluminum Products
ov �
Contractor Address: 1.634 SE Niemeyer Circle PSL FT. Phone Number,. 3.3r; 1177
O
K m
34952
o
Surety. (if applicable, a copy of the payment bond is attached): Amount of bond: $
z n
Name and address: n / a Phone.number:
`
Lender Name: n / a : Phone Number:
n
O
C
Lender's address:
--I
Persons within the State of Florida designated by Owner upon whom notices or other documents maybe served as provided by Secs:,.,.
713.13(i)(a)7., Florida Statutes:
Name:, n/a Phone Number:
Address:
In addition to himself or herself, Owner designates of
Lienor's Notice as provided in.Section 713.13(1)(b), Florida Statutes.
Phone number of person or entity designated by owner:
to receive a.copy of the
Expiration date of notice of commencement: (the expiration date may not. be before,the completion of construction and final payment to the
contractor,.but will be 1 year from the date of recording unless a different date is specified)
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED
IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA.SrATUTES,.AND CAN RESULT IN YOUR PAYING TWICE.FOR
IMPROVEMENTSTO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO`OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR
RECORDING YOUR NOTICE OF COMMENCEMENT.
Under penalty of perjury,.) declare'that I have read the foregoing notice of commencement and that the facts stated therein are true to the best of
my l P*Iedge and belief. , /
(Signature Owner or Lessee,lor Owner's e s Authorized Officer/Director/Partner/Manager
Hom wner
(Signatory's Title/Office)
The foregoing instrument was acknowledged before me this 16 thy of OC t . , 20 1,2
By Sallyann Kelly as homeowner for herself
Name of Person Type of authority (e.g.officer,trustee) Party on behalf of whom instrument was executied
Personally known_.Y _or produced Identification
(Signature of Notary OublicState of Florida) SHERYL D. MOORE
(Print, Type, or Stamp Commissioned Name of Notary NOTARY PUBLIC Type of Identification produced
STATE
.ryyO�+FGFLORIDA .
f .� id®IIIIIIR IWE1 W'rV1
Expires 1/16/2016
NOTICE OF COMMENCEMENT-
Permit, -No. Tax Folio No.1306-111=0001-000/0
,State ofFlorida 'County ofSt.-Lucie
The undersigned. hereby gives notice that improvement will be.made to certain real property, and in accordance with Chapter 713, Florida Statutes,
the following information is provided:in this -Notice of Commencement.
Legal Description of Property: (and street address if available): Cj
6690 Lila Court — SLFW
rn�rr >0
General description of improvement: Convert Lana ? to Catag.ory III. sunroom
o o M z rn
Owner information or Lessee information if the Lessee contracted for the improvement:.
A Cn n m
Name Sallya.nn 'Kelly
N in 0)
Address 6690 T;i l a court., Fort Pierces FT. 34951
0 � W x
Interest in property:
a
N o Z n
Name and address of fee simple titleholder (if differentfrom Owner listed above):
m
n/a
Ns �
N N 0
Contractor's Name: Master Craft. Aluminum Products
v
Contractor Address: 1634 SE Niemeyer Circle PSL FT, Phone Number:. 335'-1177
0g x
1 m
34952
Surety,(if.applicable; a copy of the payment bond is attached): Amount of bond: $.
Z 0
Name and address: n /a Phone number:
-I
r
Lender Name: n/ a ; Phone Number:
n
0
X
Lender's address:
Persons within the State of Florida designated by Owner upon whom notices or other documents maybe served as provided by SeCuo11
71.3.13(1)(a)1., Florida Statutes:
Name: n a Phone Number:
Address:
In addition to himself or herself, Owner designates of
Lienor's Notice as provided in Section 713.13(1)(b); Florida Statutes.
Phone number of person or entity designated by owner:
to receive a copy of the
Expiration date of notice of- commencement: (the expiration date may not be before the completion of construction and final payment to the
contractor, but will be 1 year from..the date of recording unless a different date is specified)
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF.COMMENCEMENT ARE CONSIDERED
IMPROPER PAYMENTS -UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES,.AND CAN RESULT IN YOUR PAYING TWICE. FOR
IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO'OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR
RECORDING YOUR -NOTICE OF COMMENCEMENT. -
Under penalty of perjury,.) declare'that I have read the foregoing notice of commencement and that the facts stated therein.are, true to the best of
my Awledge and belief. j
(Signature. �gowner or Lessee,lor Owner's qrtt3see's Authorized Officer/Director/Partner/Manager
r �1
(Signatory's Title/Office)
The foregoing instrument was acknowledged before me this 16 thy of Oct. , 2o' 1,2
By Sallyanri Kelly
Name of Person
as homeowner for herself.
Type of authority (e.g.office r,trustee) Party on behalf of whom instrument was executied
/(1U/2QJu A/ )� Personally known_( or produced Identification
(Signature of Notary Vublic - State of Florida) SHERYL D. MOORE
(Print, Type, or Stamp Commissioned Name of Notary NOTARY PUBLIC 'Type of Identification produced
STATE OF FLORIDA
Cart# EE156461
expires 1/16/201.6
PLANNING & DEVELOPMENT SERVICES DIVISION
BUILDING & CODE REGULATIONS DIVISION
2300 Virginia Ave
�M Fort Pierce, FL:34982
BUILDING PERMIT
SUB -CONTRACTOR SUMMARY
Master Craft Aluminum Products will be using the following.sub-contractors for the
(Company/Individual. Name)
project located at 6690 Lila ,Court — Spanish Lakes Fairways
(Street address or Property Tax ID #j '
It is •understood.that -if there is any change of status regarding the participation of. any of the sub -contractors
listed below, I will immediately advise the Building and Zoning Department of St: Lucie County.
Trade
Name of Company/Contractor
St. Lucie County/
State of Florida
License. Number
Electrical
Don Cannon Electric Inc.
'3087
0012115
Plumbing
HVAC/
Mechanical
.Roofing
Gas
OFFICE _USE_ONLY .
PERMIT ISSUE DATE:
NUMBER:
PLANNING & DEVELOPMENT SERVICES DEPARTMENT
BUILDING & CODE REGULATIONS DIVISION
BUILDING PERMIT
SUB -CONTRACTOR AGREEMENT
St. Lucie County Contractor Certification Number: JM7
State of Florida Certification Number (If applicable): M0119-
?-,%AJ 0&"k i �, 5�`��JC, have agreed to be the
(Company Name/Individual Name)
A"ICAL, sub -contractor for
(Type of Trade) (Primary Contractor)
for the project located at 4�% )/lA U
(Project Street Address or Property Tax 1D #)
It is understood that, if there is any change of status regarding our participation with the
above mentioned project, I will immediately advise the Building and Zoning Department
of St. Lucie County by personally filing a Change of Contractor notice. (Form: SLCCDV
No. 004-00)
BUSINESS QUALIFIER (Name of the individual shown on the Contractor's License)
ORIGINAL SIGNATURES ARE REQUIRED
O Fospill- [>
SIGNATURE PRINT NAME DATE
Business Name:
Address:
City/State/Zip:
Phone:
-)7oa -4�11- RV
OFFICE USE ONLY:
PERMIT # ISSUE DATE
'" ""`'0/16/2012 09:05 77233F,__,0
10/16/21112 09:57 772i_ _ '656
�c4'.�x►?•t1 �1 iV it�YLi*/ 1±�,���: � rrrs•
NE r
FILE
dedz Am"_
A
f
0
yit
PAGE 03/03
PAGE 01 / 01
MIN, SETOACK REQ,
tIDF:� -.�. •
-o3•!J
Chapter 4 - Glass Enclosures
-FIa �i y
5" COLUMN (SHOWN) o
COLUMN SIZED PER TABLE 403
zz
a
THICKNESS AND LENGTH
PLACEMENT OF 1X2
0
OF ANGLES,BY TABLE
SOLE -PLATE
a
INCIDENTAL TO DESIGN
CONCRETE ANCHORS, NUMBER,
z
DIAMETER AND MINIMUM
EMBEDMENT PER TABLE 407 (TYPICAL)
i
+
2" MINIMUM
w
t—Uj.
zw
m
w
O
Q
z
Ln
v,
w
FrX.F r)TSTAN('F
(PER TABLE 413)
COLUMN / FOUNDATION FASTENING (BEARING WALL)
SELECT LOAD CONDITIONS BY BEAM SPAN & SPACING IN TABLE 402
w
x
f-
3" COLUMN SHOWN SIZE
COLUMN PER TABLE 403
PLACEMENT OF 1X2 SOLE
PLATE INCIDENTAL TO 'DESIGN
0 G 12" MINIMUM
w
m
O
0
z
AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2010 Edition) 2.0
Chapter 4 - Glass Enclosures
1 X 2 OB @ PERIMETER
1" X 1" X 1/8" ANGLES 2" LONG WITH 2-#8 X 1/2" LONG
S.M.S. AT EACH LEG TYPICAL EACH SIDE, TOP & BOTTOM)
°
. S'F STRUCTURE ELEMENTS ° .•
w
S
CONNECTION WITH EXPOSED FASTENE rILE C-C)PY.-
€I
O
F i 1--1 X 2 OB @ .PERIMETER �
I. REFER TO NOTE #1 - THIS SHEET
I i 2- # 10 S.M.S..FROM.INSIDE-FACE OF
1 X.2.06 INTO SCREW SPLINES OF o
1 X 2 OB (1" EMBEDMENT MINIMUM.) o
0
w
U
7
O
a
w
HOST,STRUC; ;URE°ELEMENTS
CONNECTION WITH CONCEALED FASTENERS
PARTIAL ELEVATIONS / 1X2 TO 1X2 CONNECTIONS.
AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2010 Edition) 2.0
0
z
0
1
Chapter 4 - Glass Enclosures
1 X 2 OB @ PERIMETER
~FASTEN PER NOTE #1
2" X 2" HOLLOW
HORIZONTAL (GIRT)
I
�
1" X 1" X 1/8" ANGLES
2" LONG WITH
2- #8 X 1/2" LONG
S.M.S. AT EACH LEG.
(TYPICAL TOP &
BOTTOM)
Ci 07V�NE i t^ONFUV/FEXPOSEDFASTEIVERS
1 X 2 OB @ PERIMETER
FASTEN .PER NOTE #1
1" X 2-1/4" X 1/8"
RECEIVING CHANNEL
/ COLUMN
�py1 X 2 OB @ PERIMETER., CO
if- FASTEN PER NOTE #1
2" X 2" HOLLOW
HORIZONTAL (GIRT)
NOTE,#: USE 1/4"0 X 3" LONG LAG SCREWS INTO -
WOOD HOST AND 1/4"0 X 21/4"LONG CONCRETE
SCREWS INTO CONCRETE OR MASONRY CONSTRUCTION
(I- EMBEDMENT TYPICAL) SPACING 24" O.C. AND
WITHIN 4" OF EACH PERPENDICULAR MEMBER
2- # 10 S.M.S. FROM INSIDE FACE
OF 1 X 2 OB INTO SCREW SPLINES
JLOF HOLLOW GIRT (1" EMBEDMENT
MINIMUM.)
CONNECTION W/ CONCEALED FASTENERS
PARTIAL ELEVATIONS / 2 X 2 GIRT TO I X 2 CONNECTIONS
AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2010 Edition) 2.0
_;japter 4 - Glass Enclosures - Exposure B`
U-
O
z
O
H
w
S
H
z
w
m
0
0
CD
N
lit
ALLOWABLE SPANS / HEIGHTS FOR POSTS IN GLASS ROOMS (ENCLOSED STRUCRIRES)
Table 403e WIND REGION = 150 MPH ZONE Exposure B
Applied Unit Load=29.0
6005 TS.Allo Post S acing (Load Width
Post Extrusions
4'4"
61627
5-0"
5-6"
6'-0"
6'-6"
7-0"
7'-6"
8'-0"
2 X 4 X 0.050 X 0.116 SMB
7-7"
7-2"
6-10"
6-6"
6'-3"
5'-11"
5-9"
T-7"
5'-5"
2 X 5 X 0:050 X 0.116 SMB
7-11"
7-6"
7'-1"
6'-9"
6'-6"
6'-2"
5'-11"
5'-9"
5'-7"
2N 6 X 0.050 X 0.120 SMB
9'-1"
8'-7"
8'-2"
7-9"
7-5"
7'-2"
6'-10"
6'-8"
6-5"
2 X 7 X 0.055 X 0.120 SMB
10'-4"
9'-9"
9'-3"
8'-10"
8'-5"
8'-1"
7-10"
7'-7"
74'
2 X 8 X 0.072 X.0.224 SMB
16'-1"
15'-6"
14'-11" "
14'-6"
14'-1"
13'4"
13'4"
13'-1"
12'-9"
2 X 9 X 0.082 X 0.306 SMB
10-11"
18'-2"
17-7"
17-0"
16'-6"
16-1"
15'-9"
15'-4"
15-0"
2 X 3 X 0.090 X 0.090 Hollow
6'-7"
6'4"
6'-1"
5'-11"
5'-9"
5%7'
5'=5"
5'4"
5--2--
2 X 3 X 0.125 X 0.125 Hollow
7-2"
6'-11"
6'-8"
6'-6"
6'4"
6'-2"
5'-11"
5'-10"
5'-9"
2 X 4 X 0.050 X 0.050 Hollow
6'-6"
6-1"
5'-9"
5'-6"
5'=3"
5'-1"
4'-11"
4'-9"
4'-7"
.2 X 4 X 0.090 X 0.090 Hollow
8'-3"
7-11"
7-8"
7-5"
7-3".
7-0"
6'-10"
6'-8"
6'-7"
2 X 4 X 0.125 X 0.125 Hollow
9'-1"
8'-9"
8'-6"
8'-2"
7-11"
7-9"
7-7"
7-5"
7-3"
2 X 5 X 0.050 X 0.:050 Hollow
7-7"
7-2"
6'-9"
6'-6"
6'-2"
5'-11"
5'-9"
5-6"
5'-4"
3 X.3 X 0.090 X 0.090 Square
7-3"
6-11"
6'-9"
6'-6"
6'-4"
6'-2"
5'-11"
5'-10"
5'-9"
S3�X3MXOK125±X+OSi25?S' ua7e
711"
.��70�;
7-5"
7-2" 1
6-11"
6'-9"
6'-7"
6-6"
6'-4"
4.X 4 X 0.125 X 0.125 Hollow
10'-9"
10'-4"
9'-11"
9'-8" 1
9'-5"
9'-2"
8'-11"
8'4"
8'-6"
ALLOWABLE SPANS / HEIGHTS FOR POSTS IN GLASS ROOMS •(ENCLOSED STRUCTURES)
Table 403f WIND REGION = 160 MPH ZONE Exposure B
Applied Unit Load=33.0
6005 T5 Alloy Post Spacing (Load Width)
Post Extrusions
4'-0"
4'-6"
5'-0"
5'-6"
6'-'0"
6'-6"
7-0"
7'76"
8'-0"
2 X 4 X 0.050 X 0.116 SMB
7-0"
6-8"
6'-4"
6-0"
5'-9"
5'-6"
5'-4"
5'-2"
4'-11"
2 X 5 X 0.050 X 0.116 SMB
7'=4"
6-11"
6-7"
6'-3"
5'-11"
5'-9"
5'-7"
5'-4"
5-2"
.2 X 6 X 0.050 X 0.120 SMB
8'-5"
7-11"
7-6"
7'-2"
6'40"
6'-7"
6'-4"
6'-2"
5'-11"
2 X 7 X 0.055 X.0.120 SMB
9'-7"
9'-0"
8'-7"
8'-2"
7-10"
7'-6"
7-3"
7-0"
6'-9"
2 X 8 X 0.072 X 0.224 SMB
15'-5"
14'-10"
14'4"
13'-10"
13'-6"
13'-1"
12'-9"
12'-6"
12'-3"
2 X 910.082 X 0.306 SMB
18'-2"
17-5"
16-10"
16'-4"
15-10"
15'-5"
15'-1"
14'-8"
14'-5"
2 X 3 X 0.090 X 0.090 Hollow
6'-3"
6-0"
5-10"
5'-8"
5'-6"
5'-4"
5'-2"
5'-1"
4'-11"
2 X 3 X 0.125 X 0.125 Hollow
6'-.11"
6'-8"
6'-5"
6'-3"
6'-0"
'5'-10"
V-9"
5'-7"
5'-6"
2 X 4 X.0050 X 0.050 Hollow
5'-11"
5'-8"
5'-4"
5'-1"
4'-11"
4'-8"
4'-6"
4'-4"
4'-3"
2 X 4.X 0.090 X 0.090 Hollow
7-11"
7-7"
1 7-4"
7-1"
6-11"
6'-9"
6'-7"
6'75"
6'-3"
2 X 4 X 0.125 X 0.125 Hollow
8'-9"
8' 5 1
8'-1"
7-10"
7-8"
7-5"
7-3"
7-1"
6'-11"
2 X 5 X 0.050 X 0.050 Hollow
6-11"
6'-7"
6'=3"
5'-11"
5'-8"
5'-6"
5'-3"
5'-1"
3 X 3 X 0.090 X 0.090 Square
6-11"
6'-8"
6'-5"
6-3"
6'-1"
5'-11"
5'-9"
5'-7"
3 X 3 X 0.125 X 0.125 Square
7-8"
74"
7-1"
6'-10" -
6'-8"
6'-6"
6'-4"
4 X 4 X 0.125 X 0.125 Hollow
10'-3"
9'-11"
9'-7"
9'-3"
8'-11"
8'=9"
8'76"
8'-4"
8'-2"
Page 4B - 11 I AAF GUIDE TO ALUMINUM .CONSTRUCTION IN HIGH WIND AREAS (2010 Edition) 2..1
..riapter 4 - Glass Enclosures - Exposure BPY
- F
U_
0
z
D
J
z
O
in
d
w
a
w
x
it
a
z
0
0
N
ALLOWABLE SPANS for Secondary WALL MEMBERS Table 404
(GIRTS OR CHAIR RAILS in, Solid Walls)
FOR 140 mph -Wind Zones Exposure .B Table 404d
Nnlirl Wallc) A I. W 1. 4_ x o c
Load Width / Spacing
Extrusion
4'-0"
4'-6"
5-0"
5-6"
6-0"
6'-6"
7-0"
2X2X.046 Hollow
4'-4"
4'-1"
3-11"
T-8"
T-6"
3'25"
3'-3"
2X3X.050 Hollow
6'-6"
6'-1"
5'-9"
T-6"
5'-3"
5'71"
T-11"
2X4X.05"
7'-10"
7-7"
7-3"
6-11"
6'-7"
6'-4"
6'4"
2X3X.072"
7-10"
7-6"
7'-1" •
6'-9"
6'-6"
6'-3"
Maximum spacing (Vertical) 7 ft o.c.; maximum -allowable span 7' 10")
FOR 150mph Wind Zones Exposure B Table 404d
Nnlirl Walk) )n'n ..mac
Load Width /.S acin
Extrusion
4'-0"
4'-6"
T-0"
5'-6"
6-0"
6'-6"
7'4"
2X2X.046-Hollow
3'-11"
3'-9"
T-6"
T-4"
3'-3"
3-1"
2'-11"
2X3X.050 Hollow
5'-11"
5'-8"
5'-4"
5'-1"
4'-11"
4'-8"
4'-6"
2X4X.05"
7'-6"
7-1"
6'-9"
6'-5"
6'-2"
5'-11"
T-8"
2X3X.072"
7-4"
6'-11"
_ 6'-7"
6'-3"
6'-0"
5'-9"
T-7" '
Maximum Spacing (Vertical) 7 ft o.c.; maximum allowable span 7' 10")
FOR 160 mph Wind Zones Exposure B Table 404d
Load Width /.S acin
Extrusion
4'-0"
4'-6"
5'-0''
5'-6"
6'-0"
6'-6"
7-0"
2X2X.046 Hollow
3'-7"
3'-5"
3'-3"
T-1"
2'41"
2'-10"
2'-9"
2X3X.050 Hollow
T-7"
5'-3"
4'-11"
4'-9"
4'-7"
4'-4"
4'-2"
2X4X.05"
7-0"
6'-7"
6'-3"
5'-li"
5'-9"
T-6"
5'-4"
2X3X.072"
6'-11"
6'-6"
6'-2"
5-10"
5'-7"
5'-5"
Maximum Spacing (Vertical) 7 ft o.c.;-maximum allowable span 7' 10")"
Page 4B - 13 AAF.GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2010 Edition) 2.1
0 Cl
f a0 �o -o o .-o 0
6
y:
S N
a
cD
,
-
N (D
^
CD
.X° X X X
ksNT
"km
CO. ° olm Sadly Ann Kelly
CD
0 1 ° 6690_ Lila Ct
N 0
m
m Ft Pierre- Pl 34951.
N
Im
W
01
s
Property Information
Owner: Sally Ann Kelly
Address: 6690 Lila Ct
Ft Pierce, Fl 34951
Building Information
Wind Zone: 150 MPH.
Exposure Category: B
Minimum Building Dimension: 30 ft.
Mean Roof Height: 15 ft.
Risk Category: Il
Design
Pressure .Calculations
Opening
Location,
Device
Device
L
Device
Max Positive
Max Negative
Number
Zone
Width,(in
Height (in)
Elevation (ft)
Pressure (psf)
Pressure (psf)'
1
End
90.5
56.625 7
22.3
-28.5
2
End
... ....................... ............... ....... ........................ ..................
96
... _... _...................................... _... .._............ ............... ......_._..............__............._.._..._._....._.:...._........_.-.......-....._
56.625 7
....... _.... _... ........ ............ ................
- 22.2
......................... ..... ................. .......... ._.
-28.3
3
Int
69..125
.......................................................
56.625 7
_.._..............._.............._....
22.7
.....
-24.7
.._........
4
........_._
Int
.......................---.._ __.
36
._. ......... ....._.
80 7
...._..
23.2
.......... .....
-25.2
Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. Florida Building Code 2010 ed.
Page 1 of 1
;Florida Building Code Online Page 1 of 3
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search
Bl ui si i..ne,, s.:, G
rO e-
�� ,ER: uc Approvalssion.1 USER: Regulation roc; aA I>odt cax> AppliritionI,ist > Application Detail .. ........... . _ FILE COPY
FL # FL242-R14
Application Type Revision
Code Version 01�o
Application Status Approved
*Approved by DCA. Approvals by DCA shall be reviewed and
ratified by the POC and/or the Commission If necessary.
Comments
Archived
Product Manufacturer PGT Industries
Address/Phone/Email 1070 Technology Drive
Nokomis, FL 34275
(941)486-0100 Ext22318
druark@pgtindustries.com
Authorized Signature Jens Rosowski
jrosowski@pgtindustries.com
Technical Representative Jens Rosowski
Address/Phone/Email 1070 Technology Drive
Nokomis, FL 34275
(941) 486-0100 Ext 21140
jrosowski@pgtindustries.com
Quality Assurance Representative
Address/Phone/Email
Category Wind ws
Subcategory Horizontal Slider
Compliance Method Certification Mark or.Listing
Certification Agency Miami -Dade BCCO - CER
Validated By Miami -Dade BCCO - VAL.
Referenced Standard and Year (of Standard) Standard
TAS 201, 202, 203
Equivalence of Product, Standards
Certified By
Product Approval Method Method 1 Option A
Year
1994
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquUsDrhuM3D... 10/31 /2012
-.Florida Building Code Online
t 0
Page 2 of 3
Date Submitted 06/06/2012
Date Validated 06/07/2012
Date Pending FBC Approval I �.11
Date Approved 06/11/2012
................................................ .............. .................... ........ . ....... . .......... .. ................................................... .........................................
.Summary of Products
Mjd:pl,_N umber or Name
Description
242.1 MjjH._RW2r1r0_((_Nb' '11� o't. r _adoP
lAluminum Horizontal Roller Window
Limits of Use.
Certification Agency Certificate
Approved for use in HVHZ: Yes
P U .! Of
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: No
04/05/2017
Design Pressure: N/A
Installation Instructions
Other: Please see the Miami -Dade County Notice of
K242 R14 11 Ij -1201.04 HRZIQ.,-�df
........... ......... _ . �_.__ =...
Acceptance NOA) for product performance information,
Verified By: Miami -Dade BCCO - CER
anchorage details, and anchor type, size, and spacing
Created by Independent Third Party:
information.
Evaluation Reports
Created by Independent Third Party:
1242.2 _7�FFTEO (Large Missile impact)
WinGuard Vinyl Horizontal Roller Window
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL242._R.14. C CAC 11-11.14 ;
_. .2,06 . �.j)
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes
02/17/2016
Design Pressure:.N/A
Installation Instructions
Other: Please see the Miami -Dade County Notice of
FL242 R14 If I'l-'1114.06,odf
...... . ........ . . . . . .. ......... . .. .... . ......................... . ....... . .....................
Acceptance NOA) for product performance Information,Verified
B Miami -Dade BCCO - CER
y
anchorage details, and anchor type, size, and spacing
Created by Independent Third Party:
information.
Evaluation Reports
Created by Independent Third Party:
.1 jjHR - 610 (Non -Impact) 242.3
WF&T-rd Aluminum Horizontal Roller Window
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL242 R1,1 C CAC _1.1-1i 1 5 i"t
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: No
07/27/2016
Design Pressure: N/A
Installation Instructions
Other: Please see the Miami -Dade County Notice of
FL242 R14 11 11-1114.011-ill
NOA) for product performance information,
Verified By: Miami -Dade BCCO - CER
anchorage details, and anchor type, size, and spacing
Created by Independent Third Party:
IAcceptance
information.
Evaluation Reports
Created by Independent Third Party:
1242.4 jHR - 710 (Impact) IlWinGuard
Aluminum Horizontal Roller Window
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL242 RIA C CAC 11-1114.04.pd
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes
12/21/2016
Design Pressure: N/A
Installation Instructions
Other: Please see the Miami -Dade County Notice of
FL242-..R.14 11 1.!-1114.04.oclf-
Acceptance NOA) for product performance Information,
Verified By: Miami -Dade BCCO - CER
anchorage details, and anchor type, size, and spacing
Created by Independent Third Party:
information.
Evaluation Reports
Created by Independent Third Party:
1242.5 1111 - 810 (Large Missile Impact) JIMulti-Story
Aluminum Horizontal Roller Window
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL242 R14 C CAC 11-1114.0l.Ddf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes
01/02/2013
Design Pressure: N/A
Installation Instructions
Other: Please see the Miami -Dade County Notice of
K242 R14 11 11-1114,C)l.pd
Acceptance NOA) for product performance information,
Verified By: Miami -Dade BCCO - CER
anchorage details, and anchor type, size, and spacing
Created by Independent Third Party:
information.
Evaluation Reports
Created by Independent Third Party:
1242.6 1HR - 810 (Non -Impact) JIMulti-Story
Aluminum Horizontal Roller Window
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
F1.242 RIA C CAC 11-4114.03.pd
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: No
01/02/2013
Design Pressure: N/A
Installation Instructions
Other: Please see the Miami -Dade County Notice of
FL242 R14 11 J.1-1A14.03.r;df-'
Acceptance (NOA) for product performance information,
Verified By: Miami -Dade BCCO - CER
anchorage details, and anchor type, size, and spacing
Created by Independent Third Party:
http://www.floridabuilding.org/pr/pr_app—dti.aspx?param=wGEVXQwtDquUsDrhuM3D... 10/31/2012
;Florida Building Code Online
' I �
Page 3 of 3
information.
IlEvaluation Reports
Created by Independent Third Party:
242.7 HR -,810 (Small Missile Impact)
Multi -Story Aluminum Horizontal Roller Window
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL242 R1.4 C CAC 11.-1.114.02.od
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes
01/02/2013
Design Pressure: N/A
Installation Instructions
Other: Please see the Miami -Dade County Notice of
FL242 R14 II_7=1-11.14 J2_edf
Acceptance (NOA) for product performance information,
Verified By: Miami -Dade BCCO - CER
anchorage details, and anchor type, size, and spacing
Created by Independent Third Party:
information.
Evaluation Reports
Created by Independent Third Party:
242.8 HR-2710
JIVinyl Horizontal Roller Window
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FI-242 R14 C CAC
Approved for use outside HVHZ: Yes
FL242 R14_ CCAC 11-1114.10.cdf
Impact Resistant: Yes
fa,.24;2 R1Y CTCAC 1,,�;.;,l;,t,,;�4...,3;,I;,;p,If
Design Pressure: N/A
Quality Assurance Contract Expiration Date
Other: Please see the Miami -Dade County Notice of
12/23/2015
Acceptance (NOA) for product performance information,
Installation Instructions
anchorage details, and anchor type, size, and spacing
w"1-242 R14 11i1_1_11.-1.4.09. df
information.
1--242 R14 II 1.1. 1.11.4.1.0,od`
FL242 R14 :II 11-111.4.11.odf
Verified By: Miami -Dade BCCO - CER
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
242.9 HR-2810
JlVinyl Horizontal Roller Window
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL242 R14 C CAC 11-1114.11.I:df
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes
12/23/2015
Design Pressure: N/A
Installation Instructions
Other: Please see the'Miami-Dade County Notice of
FL242 ii 11 1.1.14.11..1d'
Acceptance (NOA) for product performance information,
Verified By: Miami -Dade BCCO - CER
anchorage details, and anchor type, size, and spacing
Created .by Independent Third Party:
information.
Evaluation Reports
Created by Independent Third Party:
242.10 SGD-2500 Window
Aluminum Horizontal Roller Window
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL242. R1.4 C CAC
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: No
05/22/2013
Design Pressure: N/A
Installation Instructions
Other: Please see the Miami -Dade County Notice of
FL242 R14 II 11.-131.0.1.6.od'
Acceptance (NOA) for product performance information,
Verified By: Miami -Dade BCCO - CER
anchorage details, and anchor.type, size, and spacing
Created by Independent Third Party:
information.
Evaluation Reports
Created by Independent Third Party:
[3act: Rext
Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not
send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395.
*Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department
with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public
record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.
To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
r{'P 'F.Ew".
'YX' :ii.iSLX.�[: x;"C'Ar:1l-tip
E
*rlA�Y
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquUsDrhuM3D... 10/31 /2012
MI� Dip►DE MIAMI—DADE COUNTY, FLORIDA
PRODUCT CONTROL.SECTION
DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY 11805 SW 20 Street, Room 208
AFFAIRS (PERA) Miami, Florida 33175 2474
BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.nov/pera/
PGT Industries; Inc.
1070 Technology Drive
North Venice, FL 34275
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami —Dade County PERA
—Product Control Section to be used in Miami —Dade County and other areas where allowed by the
Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami —Dade County Product
Control Section (In Miami —Dade County) and/ or the AHJ (in areas other than Miami —Dade County) reserve
the right to have this product or material tested.for quality assurance purposes. If this product or material
fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ
may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction.
PERA reserves the right to revoke this acceptance, if it is determined by Miami —Dade County Product
Control Section that this product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building _
Code, including the High Velocity Hurricane_Zone.
DESCRIPTION: y
- 'tom. '^r.`',4 ,-t . ,:. __..,�y:.�-------•_:
APPROVAL DOCUMENT: Drawing No. MD—HR210=41- titled Series "Horizontal Roller Window
Details", sheets 1 through 7 of 7, prepared by manufacturer, dated 10/14/11 with the latest revision,
prepared by PGT Industries, Inc., dated 03/23/12, signed and sealed by Anthony Lynn Miller, P. E., bearing
the Miami —Dade County Product Control Approval stamp with the Notice of Acceptance number and
Approval date by the Miami —Dade County Product Control Section.
MISSILE IMPACT RATING: None.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state,
model/ series and following statement: "Miami —Dade County Product Control Approved" unless otherwise
noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been Bled and there has been
no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change
in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement
of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure
to comply with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami —Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed, then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA consists of -this page 1, evidence pages E-1 and E-2, as well as approval document mentioned
above.
The submitted documentation was reviewed- by Jaime D. Gascon, P. E. .
MIAMI•DADE COUNTY S NOA No. 11-1201.04
tz ation Date: April 05, 2017
9j 2a C-0
P,f
royalDate: April 05,2012
Page 1
PGT Industries, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
A. DRAWINGS
1. 'Manufacturer's die drawings and sections.
2. Drawing No. MD-HR21041 titled Series "Horizontal Roller Window Details",
sheets 1 through 7 of 7, prepared by manufacturer, dated 10/14/11 with the latest
revision, prepared by PGT Industries, Inc., dated 03/23/12, signed and sealed by
Anthony Lynn Miller, P. E.
B: TESTS
1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94
4) Forced Entry Test, Type "A" window, Grade 10, per FBC 2411
section 3.2.1, TAS 202=94 and per ASTM F 588-04
5) Deglazing Force Test Method A, per ASTM E 987-88 (2001)
6) Standard Test Method for Determination of Operating Force of
Sliding Windows and Doors per ASTM E2068=00 (2008)
Along with marked —up drawings and installation diagram of an Aluminum horizontal
sliding window, prepared by Fenestration Testing Laboratory, Inc., Test Reports
No.'s FTL-6657 and FTL 6658, dated 10/17/11 and 10/18/11, both signed and
sealed by Marlin D. Brinson, P. E.
C. CALCULATIONS
1. Anchor calculations and structural analysis; complying with FBC-2010, dated
11/09/11, prepared by PGT Industries, Inc., dated 03/22/12, signed and sealed by
Anthony Lynn Miller, P. E.
2. Complies with ASTM E1300-02/ 04
D. QUALITY ASSURANCE
1. Miami —Dade Department of Permitting, Environment, 'and Regulatory Affairs
(PERA)
E. MATERIAL CERTIFICATIONS
L . None.
E-1
Jaime D. Gascon, P. E.
Product Control Section Supervisor
NOA No.11-1201.04
Expiration Date: April 05, 2017
Approval Date: April 05, 2012
PGT Industries, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
F. STATEMENTS
1. Statement letter of conformance and compliance with the FBC-2007 (with the 2009
supplement) and FBC 2010 including the HVHZ,' dated 11/07/11, signed and sealed
by Anthony Lynn Miller, P. E.
2. Statement letter of no financial interest and independence, dated 11/07/11, signed and
sealed by Anthony Lynn Miller, P. E.
3. Laboratory addendum letter for Test Reports No.'s, FTL-6657 and FTL-6658, issued
by Fenestration Testing Laboratory, Inc., dated 03/22/12, signed and sealed by Marlin
D. Brinson, P. E.
4. Laboratory compliance letter for Test Reports No.'s FTL-6657 and FTL-6658,
issued by Fenestration Testing Laboratory, Inc., dated 10/17/11 and.10/18/11, both
signed and sealed by Marlin D. Brinson, P. E.
G. OTHERS
1. None.
E-2
r
Jaime D. Gasco , P. E.
Product Control Section Supervisor
NOA No. 11-1201.04
Expiration Date: April 05, 2017
Approval Date: April 05, 2012
GENERAL NOTES: SERIES 210 NON -IMPACT
HORIZONTAL ROLLER WINDOW
1) THIS PRODUCT HAS BEEN DESIGNED & TESTED TO COMPLY
WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE,
INCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ).
2) SHUTTERS ARE REQUIRED WHEN USED IN WIND-BORNE
DEBRIS REGIONS.
3) FOR MASONRY APPLICATIONS IN MIAMI-DADE COUNTY. USE
ONLY MIAMI-DADE COUNTY APPROVED MASONRY ANCHORS.
MATERIALS USED FOR ANCHOR EVALUATIONS WERE SOUTHERN
PINE, ASTM C90 CONCRETE MASONRY UNITS AND CONCRETE WITH
MIN. KSI PER ANCHOR TYPE, SEE TABLE 1, SHEET 1.
4) ALL WOOD BUCKS LESS THAN 1-1/2"THICK ARE TO BE
CONSIDERED I INSTALLATIONS. IX WOOD BUCKS ARE OPTIONAL
IF UNIT IS INSTALLED DIRECTLY TO SUBSTRATE. WOOD BUCKS
DEPICTED AS 2X ARE 1-1/2" THICK OR GREATER. IX AND 2X BUCKS
(WHEN USED) SHALL BE DESIGNED TO PROPERLY TRANSFER
LOADS TO THE STRUCTURE. WOOD BUCK DESIGN AND
INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR
ARCHITECT OF RECORD.
6) ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND
WALL DRESSING OR STUCCO. USE ANCHORS OF SUFFICIENT
EMBEDMENT AS SPECIFIED ON TABLE 1, SHEET 1. NARROW JOINT
SEALANT IS USED ON ALL FOUR CORNERS OF THE FRAME.
INSTALLATION ANCHORS SHOULD BE SEALED. OVERALL
SEALINGIFLASHING STRATEGY FOR WATER RESISTANCE OF
INSTALLATION SHALL BE DONE BY OTHERS AND IS BEYOND THE
SCOPE OF THESE INSTRUCTIONS.
6) SHIMS ARE REQUIRED AT EACH ANCHOR LOCATION WHERE
THE PRODUCT IS NOT FLUSH TO THE SUBSTRATE. USE SHIMS
CAPABLE OF TRANSFERRING APPLIED LOADS. SHIM TO BE NO MORE
THAN 1/4" THICK. WOOD BUCKS, BY OTHERS, MUST BE
SUFFICIENTLY ANCHORED TO RESIST LOADS IMPOSED ON THEM BY
THE WINDOW.
7) DESIGN PRESSURES:
A. NEGATIVE DESIGN LOADS BASED ON STRUCTURAL TEST
PRESSURE, FRAME ANALYSIS AND GLASS PER ASTM E1300-04.
B. POSITIVE DESIGN LOADS BASED ON WATER TEST PRESSURE,
STRUCTURAL TEST PRESSURE, FRAME ANALYSIS AND GLASS PER
ASTM E1300-04.
8) THE ANCHORAGE METHODS SHOWN HAVE BEEN DESIGNED
TO RESIST THE WINDLOADS CORRESPONDING TO THE REQUIRED
DESIGN PRESSURE. THE 33 113 % STRESS INCREASE HAS NOT BEEN
USED IN THE DESIGN OF THIS PRODUCT. THE 1.6 LOAD DURATION
FACTOR WAS USED FOR THE EVALUATION OF ANCHORS INTO
WOOD, ANCHORS THAT COME INTO CONTACT WITH OTHER
DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE
FLORIDA BUILDING CODE FOR CORROSION RESISTANCE
9) REFERENCES: TEST REPORTS FTL-6657 & 6658; ELCO
ULTRACON NOA; ELCO CRETEFLEX NOA; ANSI/AF&PA NDS FOR
WOOD CONSTRUCTION AND ADM ALUMINUM DESIGN MANUAL.
10) THE 210 SERIES HORIZONTAL ROLLER WINDOW WAS
FORMERLY KNOWN AS THE 201 SERIES.
DESIGN PRESSURE RATING
IMPACT RATING
VARIES,
SEE SHEETS 3 & 4
NOT RATED FOR
IMPACT RESISTANCE
HE
A
63"
HEIGHT
62° 11
BUCK
HEIGHT
120"WIDTH
I iff - oucn vnv in
B SHEETS
6&6
58-118,
58-718"
SASH
VISIBLE
FIXED
VISIBLE
LIGHT
LIGHT
26.9/16"
SASH
VISIBLE
56-3/18"FIXED
VISIBLE LIGHT
LIGHT
ALWAYS SEE NOTE A, SEE NOTES B & C.
B
REQUIRED THIS SHEET THIS SHEET
3'
® CORNERS
TYPXQX 1/4'1/2 1/4) ELEVATION ;
}74"
WIDTH
3° BUCK WIDT
II r8 SnE7S
TABLE I:
C
2'
GHT
71"
BUCK
HEIGHT
65-718"
SASH
VISIBLE
LIGHT
I 67-118"
FIXED
VISIBLE
LIGHT
33-9/16"
33-9116°
SASH
FIXED
VISIBLE
VISIBLE
LIGHT
LIGHT
UE
SHEETS
C5&6
ALWAYS 3" —►rr= t--B —►T 1.F- 3-3/16"
GENERAL NOTES ............................1
ELEVATIONS ....................................
1
ANCHOR SPECIFICATIONS ............
1
ANCHOR SPACING/QUANTITIES...
2
DESIGN PRESSURES; XO/OX........
3
DESIGN PRESSURES, XOX............
4
INSTALLATION, STD MR .................
5
INSTALLATION, HD MR ...................
6
GLAZING DETAILS ..........................
7
CORNER ASSEMBLY ......................
7
EXTRUSION PROFILES ..................
8
PARTS LIST .....................................
8
SHEETS
5&6
HI
1-- 3-3118"
00" WIDTH
•
— - 89' BUCK WIDTH
SHEETS
B
5&6
26-318'
A
FIXED y
/
LIGHT
LIGHT
/
83'
IGHT
62°
56-718°
SASH
VISIBLE
LIGHT
"`ill���
58.118"
FIXED
VISIBLE
LIGHT
/I
/
BUCK
HEIGHT
2S-7/16"
SASH
VISIBLE
LIGHT
THIS SHEET
3
A SHEETS
5&6
Anchor
Anchor
Substrate
Min. Edge
Min.
Cemse '•gyp ���
Ss�
A. LYNN MILLER, P.E.
RES 58705
WEEPHOLE NOTES. (SEE WEEPHOLE DETAILS, SHEET 7 OF 8):
A. REQUIRED IF WINDOW WIDTH IS OVER 67". -
B. REQUIRED IF WINDOW WIDTH IS OVER 45" AND UP TO 67'.
C. REQUIRED IF WINDOW WIDTH IS OVER 89", --
D. REQUIRED IF WINDOW WIDTH IS OVER 45". `z -
Approyed w ootnplying
FioddaDull big Co
Dote p (Z
Revised By: Dale: Revision: NOA# — OGtt-
o Canino
Revised By: Dale: Revielon:
® Deearfptlon: - - Drown By:
GENERAL NOTES & ELEVATION J ROSOWSKI
1070 TECHNOLOGY DRIVE 7711e: - Dale:
N. VENICE, IL 34275 HORIZONTAL ROLLER WINDOW DETAILS 12/01/11
P.O. BOX 1529
NOKOMIS.' FL 34274 Senea/bfodah Saole: Sheet: Dmwing No. Rev:
CERT. OF AUTH. #29296 HR-210 NTS 1 OF 8 0-HR210-01
1 ANCHOR ON
1 ANCHOR AT EACH SIDE OF
CORNER THE MEETING
RAIL
MIN.3
ANCHORS IN
JAMB FOR
WINDOWS UP
TO 44'; MIN. 4
ANCHORS IN
JAMB FOR
WINDOWS
OVER 44'
1 ANCHOR AT
CORNER
6' MAX.
SEE TABLE 2,
1 ANCHOR ON
THIS SHEET, FOR
1 ANCHOR ON
EACH SIDE OF
ANCHOR
EACH SIDE OF
.1 ANCHOR AT THE MEETING
QUANTITIES
THE MEETING
CORNER RAIL
RAIL
MIN. 3
ANCHORS IN
JAMB FOR
17" MAX. O.C. FOR
WINDOWS UP
WINDOWS UP TO 63"
TO 44', MIN,4
TALL, 20' MAX. O.C.
ANCHORS IN
FOR WINDOWS OVER 63"
JAMB FOR
WINDOWS
OVER 44"
B' MAX.
6" MAX. —►-, I+— 6' MAX. FROM
�►— CENTER OF
MEETING RAIL (X2)
ANCHORAGE FOR ALO'X GX CONFIGURATIONS
1 1
1 ANCHOR ON ANCHOR 1 ANCHOR ON
1 ANCHOR AT EACH SIDE OF AT EACH SIDE OF CORNER 1 ANCHOR AT
THE MEETING FIXED THE MEETING
rrhanlcha I
MIN. 3
ANCHORS IN
JAMB FOR
WINDOWS UP
TO 44", MIN. 4
ANCHORS IN
JAMB FOR
WINDOWS
OVER 44"
6" MAX. —
9.
6" MAX
17" .0
�
a
a
~) r— MEETING RAIL (X2)
ANCHORAGE FOR ALL XOX (1/3-1/3-1/3) CONFIGURATIONS
8' MAX.
X.
1 ANCHOR AT
CORNER 1
6" MAX
17" Mh
o.c
a
a
A
6' MAX
I
22314" I
... —►I )�— ---IMAX. O.Cf�
MEETING RAIL (X2)
ANCHORAGE FOR ALL-'OX(u1/41t2=;1'7.4) CONFIGURATIONS
t'•�.-.; _ ..._ ;. . - it
TABLE 2:
FRAME
TYPE
FRAME
WIDTH
FRAME HEIGHT
30318"
44"
505/8"
63"
ANCHOR GROUP
ANCHOR GROUP
ANCHOR GROUP
ANCHOR GROUP
A
B
C
A
B
C
A
B
C
A
B
C
53-1/8"
1
1
1
1
1
1
1
1
1
1
1
.1
74"
2
2
1
1
2
1
1,
1
1
1
1
1
STANDARD
MEETING
85"
2
2
2
2
2
1
1
2
1
1
1
1
RAIL
97"
2
3
2
2
2
2
2
2
1
1
1
1
109"
3
3
2
2
3
2
2
2
2
1
2
1
120"
3
3
3
3
3
2
2
2
2
2
2
1
63.1/8"
1
1
1
1
1
1
1
1
1
HEAVY.
74"
2
2
1
2
2
1
1
1
1
DUTY
8.5"
2
2
X13
2
2
2
2
2
2
1.
XO, OX & XOX:
EGRESS HEIGHT: WH -4-518
XO & OX:
EGRESS WIDTH: (WW/2-3.1/2)
XOX (1/4-1/2-1/4):
EGRESS WIDTH:. (WW/4 - 2-5118)
XOX (1/3-1/3-1/3):
EGRESS WIDTH: (WW/3-6).
X.
XO, OX & XOX:
SASH VISIBLE LIGHT HEIGHT: (WH - 6-1/8)
FIXED VISIBLE LIGHT HEIGHT: WH -4-7/8
XO & OX:
SASH & FIXED VISIBLE LIGHT WIDTH: (2 - 3-7/18
XOX (1/4.1/2-1/4):
SASH VISIBLE LIGHT WIDTH: (WW/4-3.7/16)
FIXED VISIBLE LIGHT WIDTH: (WW12 - 3-13116)
XOX (1/3.1/3.1/3):
SASH & FIXED VISIBLE LIGHT WIDTH: (W W/3 - 3.9116)
MEETING 97" 2 3 2 2 2 2 2 2 2 - f
RAIL 109' 3 3 3 3 3 2 2 2 2
120" 3 4 3 3 3 3 2 2 2
SEE TABLE 1, SHEET 1 FOR ANCHOR GROUP DESCRIPTIONS. Approved as complying with I he
FloridaB U ing Cod
Date O 5' 26/0
/�� Revised By: Dole: Revision: lYOAN • 04
�YNN Mi4� �a tConnnl
`����'�•'��GENSE •'•�'P ��
Q. ; •'. * Revised By: Dole: Revision: Y
* : No.58705
0 Description. Droen By:
1/k" ANCHOR SPACING & QUANTITIES J ROSOWSKI
:�o '• i TE IF tv�
0•'• ST TE F 1070 TECHNOLOGY DRIVE 776e: Dole:
FC...... ' C9; N. P.O. B, FL 34275 52 HORIZONTAL ROLLER WINDOW DETAILS 12/01/11
''��%csSlONA1-�\ NOKC MIS,C FL 134274 Senes/Modeh. Scale: Sheol; Drawing No. Rer.
A L4p,E,g68 p ' RE CERT. OF AUTH. $29296 HR-210 NTS 2 OF 8 MD-HR210-01
TART F A•
oR OX
CONFIGURATIONS
MAXIMUM DESIGN PRESSURE RATING (psf)
FRAME
STANDARD MEETING RAIL
HEAVY DUTY MEETING RAIL
WIDTH
CTYPE-LASS
TYPE
FRAME HEIGHT
FRAME HEIGHT
383/8"
44"
50-516,
63"
38-3/8"
44"
505/8"
63"
72"
Glass 1
+55.0/-90.0
+55.0/-90.0
+55.0/-86.9
+55.0/-67.9
+55.0/-90.0
+55.01-90.0
+55.0/-86.9
+55.0/-67.9
N/A
26-1/2"
Glass 2_& 3
+55.0/-90.0
+55.0/-90.0
+55.0/-90.0
+55.0/-90.0
+55.0/-90.0
+55.01-90.0
+55.0/-90.0
+55.01-90.0
+55.01-90.0
Glass 4 & 5
+55,01-90.0
+55.0/-90.0
+55.01-90.0
+55.0/-90.0
+55.0/-90.0
+55.01-90.0
+55.0/-90.0
+55.0/-90.0
+55.01-90.0
Glass 1
+55.0/-73.5
+55.01.61.2
+55.01-56.0
+49.7/-49.7
+55.0/-73.5
+55.01-61.2
+55.0/-56.0
+49.7/49.7
. WA
37"
Glass 2 & 3
+55.01-90.0
+55.0/-90.0
+55.01-87.2
+55.01.67.2
+55.0/-90.0
+55.01-90.0
+55.0/-90.0
+55.01-90.0
+55.0/-77.9
Glass 4 & 5
+55.01-90.0
+55.01-90.0
+55.0/-90.0
+55.0/-84.0
+55.0/-90.0
+55,0/-90;0
+55.01-90.0
+55.01-90.0
+55.0/-78.1
Glass 1
+55.0/-67.5
+63.7153.7
+44.6144.6
+35.5A35.5
+55.0/-67.5
+53.7/-53.7
+44.6144.6
+35.61-35.5
NIA
45"
Glass 2
+55.01-90.0
+55.0/-90,0
+55.01-75.0
+55.0/-57.1
+55.0/-90.0
+55.0/-90.0
+55.01-89.2
+55.0/-77.2
+55.01.65.8
Glass 3
+55.01-90.0
+55.0/-90.0
+55.0/-75.0
+55.0/-57.1
+55.0/-90.0
+55.01-90.0
+55.0/-80.3
+55.01.63.9
+55.0/-57.1
Glass 4 & 5
+55.01-90.0
+55.0/-90.0
+55.01-90.0
+55.0/-71.4
+55.0/-90.0
+55.01-90.0
+55.0/-90.0
+55.0/-77.4
+55.0/-66.0
Glass 1
+55.0/-66.0
+53.1/-53:1
+43.61-43.6
+32.3/-32.3
+55.0/-66.0
+53.11-53.1
+43.6/43.6
+32.3/32.3
N/A
49"
Glass 2
+55.0/-90.0
+55.0/-85.1
+55.01-70.5
+53.4/-53.4
+55.0/-90.0
+55.01-88.9
+55.01-79.9
+55.0/-68.0
+55.01.61.3
Glass 3
+55.0/-90.0
+55.0/-85.1
+55.0170.5
+53.4/-53.4
+55.0/-90.0
+55.01-90.0
+55.0/-78.5
+55.0/58.1
+50.61-60.6
Glass 4 & 5
+55.01-90.0
+55.0/-90.0
+55.01-88.1
+55.0/-66.7
+55.0/-90.0
+55.01-90.0
+55.0/-90.0
+55.01-72.3
Glass 1
+55.01-63.7
+52.4/-52.4
+43.5/43.5
+31.21-31.2
+65.0/-63.7
+52.4152.4
+43.51-43.5
+31.21-31.2
WA
53A/8"
Glass 2
+55.01-90.0
+55.0/-81.0
+55.01.66.7
+50.2/-50.2
+55.0/-90.0
+55.0/-85.0
+55.01-73.8
+55.01-59.4
+54.0/-54.0
Glass 3
+55.01-90.0
+55.0/51.0
+55.0/-66.7
+50.2/-50.2
+55.0/-90.0
+55.01-90.0
+55.01-78.3
+56.01-56.2
+46.8/46.8
Glass 4 & 5
+55.01-90.0
+55.01-90.0
+55.0A83.4
+55.01-62.7
+55.0/-90.0
+55.0/-90.0
+55.0/-90.0
+55.01-68.0
+55.0/-57.4
Glass 1
+55.0/-59.2
+60.4/-50.4
+42.8142.8
+31,8/-31.8
+550-59.2
+50.4/50.4
+42.81.42.8
+31.8/-31.8
N/A
61"
Glass 2
+55.0/-89.2
+55.01-75.1
+55.01.61.1
+45.4/-45.4
+55.0/-89.2
+55.01-79.3
+55.0/-67.2
+51.0/-51.0
+44.01.44.0
Glass 3
+55.0/-90.0
+55.01-75.1
+55.0/51.1
+45.4/45.4
+55.0/-90.0
+55.01-90.0
+55.01-77.0
+55.0157.2
+46.41-46.4
Glass 4.& 5
+55.0/-90.0
+55.0/-90.0
+55.0/-76.4
+55.0/-56.7
+55.0/-90.0
+55.01-90.0
+55.0/-82.9
+55.0/-61.5
+51.61-51.8
Glass 1
+55.0/-56.3
+48.5148.5
+41.6/41.6
+32.0/-32.0
+55.0/-56.3
+48.5/48.5
+41.6/41.6
+32.0/-32.0
N/A
66"
Glass 2
+55.0/-79.7
+55.0/-72.5
+65.0158.5
+43.0/43.0
+55.0/-79.7
+55.0/-77.1
+55.0/-65.2
+49.3/49.3
+41.2/41.2
Glass 3
+55.0/-79.7
+55.0/-72.5
+55.0/58.5
+43.0/-43.0
+55.0/-79.7
+55.0/-79.7
+55.0/-74.9
+55.01.57.6
+47.01.47.0
Glass 4 & 5
+55.0/-79.7
+55.0/-79.7
+55.0/ 73.1
+53.8/-53.8
+55.0/-79.7
+55.01-79.7
+55.0/-79.3
+55.0158.3
+48.9148.9
Glass 1
+51.1/-51.1
+44.2/44.2
+38.9/38.9
+30.0/-30.0
+51.1/-51.1
+44.2144.2
+38.9/-38.9
+30.0/-30.0
N/A
Glass 2 .
+55.0/-63.5
+55.0/-63.5
+55.0/-55.3
+40.0/40.0
+55.0/-63.5
+55.0/-63.5
+55.0/-62.0
+47.9/47.9
+39.81-39.8
Glgs's13 b
+55.0/-63.5
+55.0/-63.5
+55,0155.3
-I4-OiO
+55.01-63.5
+55.01.63.5
+55.0/-63.5
+54.11-54.1
+45.0145.0
Glass 4 & 5
+55.0/-63:5
+55.0/-63.5
+55.0/-63.5
+50.0/-50.0
1, +55.0/-63.5
+55.0/-63.5
+55.0/-63.5
+54.2154.2
+45.11-45.1
TABLE 4:
Glass Types
1/8" Annealed
1/8" Tempered
2
3/18" Annealed
1/4" Annealed
r
1/8" Annealed-1/4" Alrspace-1/8" Annealed
f`'*
3/16"AAnneated-3!]8' Alrs_pace=178"Ann'eeledr
- - -
4
3/16" Tempered —
1/4" Tempered
6
1/8" Tempered-1/4" Allspace-1/8" Tempered
3/16" Tempered-3/18" Airspace-1/8" Tempered
NOTES:
1) USE THIS TABLE FOR ALL XO/OX WINDOWS PER
THE ELEVATION ON SHEET 1. DIMENSIONS SHOWN
ARE TIP -TO -TIP.
2) FOR SIZES NOT SHOWN, ROUND UP TO THE
NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION
SHOWN ON THE TABLE.
3) DESIGN PRESSURES MAY BE INTERPOLATED
BETWEEN SIZES.
CONFIGURATIONS APPLICABLE TO THIS SHEET:
xo
a
Gx
a 11
.o.npgms wall Ill.
ildu Cod"
— �l- o4
O 00
O Z O
O co
X W
.LLIHJ
of
0 Z
w J
W Q
IL F- C
IL D
JZ O N
I
N
0 _
TABLF fi-
XOX CONFIGURATION
MAXIMUM DESIGN PRESSURE RATING (pso
FRAME
WIDTH
GLASS
TYPE
STANDARD MEETING RAIL
HEAVY DUN MEETING RAIL
FRAME HEIGHT
FRAME HEIGHT
38-3/8'•
44"
50-5/6,
19.
38-3/8"
44"
50-5/8"
63"
49„
Glass 2 & 3
+55.0/-90.0
+55.0/-90.0
+55.0/-76.3
+55.0/-59.2
+55.0/-90.0
+55.0/-90.0
+55.0/-90.0
+55.0/-78.9
z
p
Glass 4 & 5
+55.0/-90.0
+55.01-90.0
+55.0/-89.1
+55.0/-69.1
+55.0/-90.0
+55.0/-90.0
+55.0/-90.0
+55.0/-90.0
53-1/8"
Glass.2 & 3
+55.0/-90.0
+55.01-84.7
+55.0/-71.4
+55.01-55.1
+55.0/-90.0
+55.0/-90.0
+55.0/-90.0
+55.0/-73.5
Glass 4 & 5
+55.01-90.0
+55.01-90.0
+55.0/-83.2
+55.01-64.3
+55.0/-90.0
+55.0/-90.0
+55.0/-90.0
+55.0/-90.0
81"
Glass 2 & 3
+55.0/-90.0
+55.0/-76.3
+55.0/-63.9
+49.0/-49.0
+55.0/-90.0
+55.0/-90.0
+55.0/-85.1
+55.01-65.3
LL
z
Glass 4 & 5
+55,01-90.0
+55.0/-89.0
+55.0/-74.5
+55.0/-57.1
+55.01-90.0
+55.0/-90.0
+55.0/-90.0
+55.0/-84.5
L))
74"
Glass 2 & 3
+55.0/-81.0
+55.0/-66.8
+55.0/-55.3
+41.9/-41.9
+55,.01-90.0
+66.01-88.9
+55.0/-73.7
+55.0/-55.8
Glass.4 & 5.
+55.01-90.0
+55.01-77.9
+55.0/-64,5
+48.8148.8
+55.01-90.0
+55:0/-90.0
+55.0/-90.0
+55.0/-72.2
r'
86'
Glass 2 & 3.
+55.0/-75:6
+55.01-61.5
+50.4/-50.4
+37.7/-37,7
+55.0/-90.0
+55.0/-81.8
+55.01-67.2
+50.3/-50.3
7
Glass 4 & 5
+55.0/-88.2
+55.01-71.7
+55.0/-58.8
+44.0/-44.0
+55.01-90.0
+55.0/-90.0
+55.01-86.9
+55.0/-65.0
cQ
90
Glass 2 & 3.
+55.0/-73.8
+55.0/-59.6
+48:6/48.6
+36.2/-36.2
+55.01-90.0
+55.0/-79.5
+55.0/-64.8
+48.2/-48.2
Glass 4 & 5
+55.0/-86.1
+55.0/-69.8
+55.01-56.7
+42.2/-42.2
+55-0/-90.0
+55.0/-90.0
+55.01-83.9
+.55.0/-62.4
Glass 2
+55.0/-90.0
+55.01-79.5
+55.01-66.4
+50.81-50.8
+55.0/-90.0
+55.0/-85.0
+55.01-73.8
+55.0/-59.4
53-1/8"
Glass 3
+55.01-90.0
+55.0/-79.5
+55.0/-66.4
+50.8/-50.8
+55.0/-90.0
+55.0/-90.0
+55.0/-78.3
+55.0/-56.2
Glass 4 & 5
+55.0/-90.0
+55.01-90.0
+55.0/-77.5
+55.01-59.2
+55.01-90.0
+55.0/-90.0
+55.01-90.0_
+55.0/-87.5
Glass 2
+55.0/-80.4
+55.01-64.9
+52.9/-52.9
+39.31-39.3
+55.0/-83.1
+55.0/-72.8
+55.0/-62.0
+47.9/-47.9
0,
74"
Glass 3
+55.01-80.4
+55.0/-64.9
+52.9/-52.9
+39.31-39.3
+55.0/-90.0
+55.0/-79.6
+55.01-70.0
+52.5/-52.5
F
Glass 4 & 5
+55.01-90.0
+55.0/-75.8
+55.0/-61.8
+45.9/45.9
+55.01-90.0
+55.0/-90.0
+55.0/-90,0
+55.0/-67.8
Glass 2
+55.01-74.7
+55.0/-61.2
+49.1/-49.1
+35.8/-35.8
+55.0/-74.7
+55.0/-67.2
+55.01-58.9
+46.8/-46.8
ooz',�
5"
G at s 3
+55.01-77.2
+55.0/-61.2
+49.1/-49.1
+3�5 P-IE 8'
d� �. �-_
+55.0%81.9
+55.0/-71.1
+55.0/ 62.8
+47.8/ 47.8
Glass 4 & 5
+55.01-90.0
+55.0/-71.4
+55.0/-57.3
+41.8/-41.8
+55.0/-90.0
+55.9/-90.0
+55.0/-84.6
+55.0/-61.8
U'
Glass 2
+55.01.65.3
+55.0/-58.8
+46.3/46.3
+33.1/-33.1
+55.0/-65.3
+55.0/-60.0
+53.7/-53.7
+43.9/43.9
Glass S�
+55.01-72.5
+55.01-58.8
+46.3/46. 3
J331_.11:333 1
�
+55.0/-72.5
+55.0/ 63.7
+54.7/-54.7
+44.2/44.2
Glass 4 & 5
+55.01-87.0
+55.0/-68.6
+54.11-54.1
+38.7/487
+55.0/-90.0
+55.0/-90.0
+55.0/-79.9
+55.0/37.1
Glass 2
+55.01-56.7
+53.4/-53.4
+44.7/44.7
+31.21-31.2
+55.0/-56.7
+53.4/-53.4
+48.4/-48.4
+40.5/-40.5
+.
109"
Glass 3
+55.0/-64.8'
+55.0/-55.8
+44.7/-44.7
+31.2/31.2
+55.0/-64.8
+55.0/-55.8
+48.2/48.2
+39.6/-39.6
r `
Glass 4 & 5
+55.0/-84.7
+55.0/-66.5
+52.2/-52.2
+36.4/-36.4
+55.0/-90.0
+55.0/-90.0
+55.0/-77.1
+53.8/-53.8
Glass 2
+49.7/49.7
+47,9/47,9
+43.6/43.6
+30.0/-30.0
+49.7/-49.7
+47.9147.9
+44.3/44.3
437.5/-37.5
120"
Glass 3
+55.0/-57.6
+51.1/51.1
+43.6/43.6
+30.0/-30.0
+55.0/-57.6
+51.1/-51.1
+44.1144.1
+35.8/-35.8
Glass 4 & 5
+55.04-83.2 1
+55.0/-65.0
+50.9/-50.9
+35.01-35.0
+55.0/-90.0
+55.0/-90.0
+55.0/-75.2 1
+51.71-51.7
TABLE 6:
Glass Types
2
3110" Annealed
1/4" Annealed
3
118" Annealed-1/4" Airspace-1/8" Annealed
3/16" Annealed-3116" Airspace-1/8" Annealed
4
3/16" Tempered
114" Tempered
5
1/8" Tempered-1/4" Alrspacei/8" Tempered
3/16" Tempered-3/16" Airspade-1/8" Tempered
NOTES:
1) USE THIS TABLE FOR ALL XOX WINDOWS PER
THE ELEVATIONS ON SHEET 1. DIMENSIONS
SHOWN ARE TIP -TO -TIP.
2) FOR SIZES NOT SHOWN, ROUND UP TO THE
NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION
SHOWN ON THE TABLE.
3) DESIGN PRESSURES MAY BE INTERPOLATED
BETWEEN SIZES.
CONFIGURATIONS APPLICABLE TO THIS SHEET:
XOX (113-1/3-1/3)
� a
XOX (114-1/2-114)
Lr011ed as conwivinn widr the
�..
o
o
a
r-
mS O
•-
-�
o
LLJ
O
O
eo
XO
ILL.Z
OX
W `
U)
rc
z
J
°w
z
w
J
d
Z
o
Z
O
N
04
8
W
aO
m
N
�
T
N
a
x
�aY
o
821 Z
``W 1 a/'''''�
N x c-j w rr . Q - n
:�. 6 r,�3:z g„
��. o'
z LL
moo. :•�co�o
INSTALLATION OPTION 1
INSTALLATION ANCHORS INTO 2X WOOD.
OPTIONAL 2X W000 DISTANCE EDGE
BO ADDON
FLANGE Q
HEAD,
SILL & JAMBS EDGE
EMBED- DISTANCE
MENT 1
T .1—
TYP.ANCHOR
TYPE, EMBEDMENT
AND EDGE —
DISTANCE PER
SUBSTRATE,SEE
TABLE 1, SHEET 1.
FIXED
VISIBLE
LIGHT
HEIGHT
IP-TO-TIP
HEIGHT
SUCK O
HEIGHT
CONCRETE/CMU
PER ANCHOR STANDARD MEETING RAIL 0
REQUIREMENT
EMBEDMENT
1/4" MAX C
e SHIM 23 XZ
30
- - _c __4 i /
TYP. ANCHOR TYPE,
EMBEDMENT AND EDGE
DISTANCE PER SUBSTRATE,
SEE TABLE 1, SHEET 1,
x
1X WOOD
BUCKSTRIP,
SEE NOTE 2, i
THIS
SO WIDTH EMBED- STANDARD STANDARD
INSTALLATION- MEETING RAIL B EXTERIOR 5 MEETING RAIL 1X BUCK WOOD MENT
OPTION 2 V INSTALLATION
INSTALLATION C'3
ANCHORS DIRECTLY BUCK WIDTH —�-ON 3
INTO MASONRY. TIP -TO -TIP WIDTH INSTALLATION (tNCHORS
THROUGH 1 X QI7CKSTRIP
SASH HORIZONTAL SECTION A -A ? : )NT6'MASONRY.
LIGHT —� 1/4" MAX. SHIM `.•i c.)
HEIGHT
#12 STEEL 5 - q 2X WOOD TYP. ANCHOR TYPEA
X SELF -DRILLING 10 X 11 EMBEDMENTAND9PGE
SMS (135), SEE TABLE DISTANCE PER SLIAeSTRATE.-
1, SHEET 1. SEE TABLE 1, SHEET 1.
DADEAPPROVED = =� = _�
32 MULLION, ALUMINUM, O
31 STEEL FRAMING OR STEEL SASH VISIBLE
STUD. SEE SUBSTRATE LIGHT WIDTH
PROPERTIES TABLE 1 -- —_-
4"CUTLENGTH SHEET I.
12 ® EACH
MEETING. RAIL EXTERIOR
INSTALLATION n 26 FIXED VISIBLE
V STANDARD LIGHT WIDTH
TYP. ANCHOR TYPE,
OPTION 4
MEETING RAIL `J
EMBEDMENT AND EDGE
INSTALLATION
2
DISTANCE PER
ANCHORS
BUCK WIDTH
29
SUBSTRATE, SEE
DIRECTLY INTO
TIP -TO -TIP WIDTH
TABLE 1, SHEET 1.
METAL'
HORIZONTAL SECTION C-C
1X WOOD
BUCKSTRIP,
NOTES: '
SEE NOTE 2,
1) USE ONLY SUBSTRATE -APPROPRIATE ANCHORS LISTED ON TABLE 1 OF SHEET 1. FOLLOW EMBEDMENT AND EDGE
TTHIS SHEET,
DISTANCE LIMITS. ANY INSTALLATION OPTION SHOWN MAY BE USED ON ANY SIDE OF THE WINDOW.
114" MAX SHIM
2) ALL WOOD BUCKS LESS THAN 1-1/2'
THICK ARE TO BE CONSIDERED 1X
INSTALLATIONS. IX WOOD BUCKS ARE
��� N�. L N • Mrs
\� 0 •' '• • C
1X WOOD
BUCK
- •c: �.
..' ". ':
�� •'y"':.
CONCRETE PER
ANCHOR
OPTIONAL. UNIT MAY BE INSTALLED
DIRECTLY TO SUBSTRATE. WOOD BUCKS
���•'' �1GENSF '•. F�
C
•'. *
I
EXTERIOR
REQUIREMENT
DEPICTEDAS2XARE1-1/2-THICKOR
*' Na.58705
GREATER. 1XAND 2X BUCKS (WHEN
USED) SHALL BE DESIGNED TO PROPERLY
—
INSTALLATION
TRANSFER LOADS TO THE STRUCTURE.
0 t5-*r2z_.s�-I✓LVERTICAL
OPTIONS
WOOD BUCK DESIGN AND INSTALLATION
�� '•. FP ;'
W.
SECTION B-B INSTALLATION ANCHORS
IS THE RESPONSIBILITY OF THE
ENGINEER OR ARCHITECT OF RECORD.
COR10 ,. G \\�
1070 TECHNOLOGY DRIVE
N. VENICE, FL 34275
TRIP.
THRONTO
MAXIMUM SHIM THICKNESS TO BE 114".
/��/SS!ONA�- �?�`
BOFL 1529
MASONRUGH Y.
//Inlntl
NOP.O.
A. LYNN MILLER, P.E.
P.E.fl 5t1705
CERT. OF AUTH. 29296
INSTALLATION
OPTION 1
INSTALLATION
ANCHORS INTO 2X
WOOD.
witfi 91a
5 64
Reviolon:
ALLATION DETAILS, STD MR I J ROSOWSKI
77tle: Dot.:
HORIZONTAL ROLLER WINDOW DETAILS 12/01/11
Seriaa/Model: Scale: Sheet: Droving No. Rev:
HR-210 NTS 5 OF 8 MD-HR210-01
INSTALLATION OPTION 1 CONCRETE/CMU
INSTALLATION ANCHORS INTO 2X WOOD. PER ANCHOR
REgUIREMENT
OPTIONAL EDGE
80 ADDON -2XWOOD DISTANCE EMBEDMENT
FLANGE @ 7
114° MAX
HEAD,
SILL & JAMBS O EDGE SHIM
EMBED- DISTANCE
MENT
1 TYP. ANCHOR
TYPE, EMBEDMENT
AND EDGE
II II DISTANCE PER
li li - SUBSTRATE, SEE
I I TABLE 1, SHEET 1.
I
FIXED
VISIBLE
LIGHT
HEIGHT
TIP-TO-TIPI
HEIGHT
BUCK
HEIGHT
'INSTALLATION
OPTION 2
INSTALLATION
ANCHORS DIRECTLY
INTO MASONRY.
SASH
VISIBLE
LIGHT
HEIGHT
HEAVY DUTY MEETING RAIL( 1XWDOD
TYP. ANCHOR TYPE, BUCKSTRIP, ' .• CONCRETE
EMBEDMENT AND EDGE SEE NOTE 2, OR CMU
DISTANCE PER SUBSTRATE. THIS SHEET, PER
11 SEE TABLE 1, SHEET 1. ANCHOR
1 93 90 REQUIRE-
3p 10:�•• MENT
J X 54 X
44—�__—
J =-- ---- SASH I Q
SASH I O VISIBLE
VISIBLE If LIGHT EDGE
LIGHT - -- WIDTH
WIDTH - ----- DISTANCE
76 FIXED
25 VISIBLE I `
24 70
LIGHT II--�� 5 i
WIDTH EMBED.
"
EXTERIOR \\\ BUCK MENT
j� 7 HEAVY DUTY HEAVY DUTY INSTALLATION
V MEETING RAIL vMEETINGRAIL OPTIONS
BUCK WIDTH INSTALLATION ANCHORS
TIP -TO -TIP WIDTH THROUGH 1X BUCKSTRIP
HORIZONTAL SECTION A -A INTO MASONRY.
1/4" MAX. SHIM
it II #12 STEEL
O �I II X SELF -DRILLING 10
jl II SMS (G5), SEE TABLE )(
II I II 1, SHEET 1. _
I I`
II ii it 32 DADE APPROVED
j MULLION, ALUMINUM,
�I 31 STEEL FRAMING OR STEEL SASH VISIBLE I __
I _ STUD. SEE SUBSTRATE "'yyyiii
II I PROPERTIES, TABLE 1, LIGHT WIDTH
4" CUT LENGTH SHEET 1.
12 h(_1 EACH
MEETING RAIL EXTERIOR 25
INSTALLATION
TYP. ANCHOR TYPE, OPTION 4 v HEAVY DUTY
EMBEDMENT AND EDGE INSTALLATION MEETING RAIL 7
DISTANCE PER ANCHORS
SUBSTRATE, SEE DIRECTLY INTO
TABLE 1, SHEET 1. METAL. - BUCK WIDTH
IXWOOD NOTES: TIP -TO -TIP WIDTH
BUCKSTRIP, 1) USE ONLY SUBSTRATE -APPROPRIATE
SEE NOTE 2, ANCHORS LISTED ON TABLE 1 OF SHEET 1.
THIS SHEET. FOLLOW EMBEDMENT AND EDGE DISTANCE HORIZONTAL SECTION C-C
1/4" MAX SHIM LIMITS. ANY INSTALLATION OPTION SHOWN
MAY BE USED ON ANY SIDE OF THE WINDOW
•'
\CENS,
lX WOOD •., t.
. •
2)ALL WOOD BUCKS LESS THAN 1-1/2"THICK
T ;'•
.
BUCK CONCRETE PER ..ARE
TO BE CONSIDERED I INSTALLATIONS. 1X
Z-* ;• •'. �C
ANCHOR
EXTERIOR <•'
WOOD BUCKS ARE OPTIONAL. UNIT MAY BE
No. 58705 -_
. REQUIREMENT
e' -' '�
INSTALLED DIRECTLY TO SUBSTRATE. WOOD
BUCKS DEPICTED AS 2X ARE 1-V2" THICK OR
INSTALLATION
GREATER. 1X AND 2X BUCKS (WHEN USED)
DESIGNED TO
'•, 7241:L •: ��
TE F :
VERTICAL SECTION
OPTION 3
B-B
LOADS TO THE STRUCTURESHALLBE
OWOOD BPERLY UCK
��•, ��[/`
��� •.�ORtO P.•' G\\�
1070 TECHNOLOGY DRIVE
INSTALLATION ANCHORS
DESIGN AND INSTALLATIONIS THE
�; ss C�`
N. VENICE. FL 34275
'
THROUGH 1X BUCKSTRIP
RESPONSIBILITY
''// ;�NAI- 1���
P.O. BOX 1529
INTO MASONRY.
OF RECORD. MAXIMUM SHIM
NOKOMIS; FL 34274
THICKNESS TO BE 1/4".
A. LYNN MILLER, P.E.
CERT. OF AUTH. #29296
P.E.958705
2X WOOD TYP• ANCHOR TYPE,
EMBEDMENT AND EDGE
DISTANCE PER SUBSTRATE,
SEE TABLE 1, SHEET 1.
E
FIXED VISIBLE
LIGHT WIDTH - INSTALLATION
OPTION 1
INSTALLATION
ANCHORS INTO 2X
WOOD.
Approved re romplyinB with Iho
PloridOU
Pro .11-0+
13Y
Deacriptlon: I Drown By.,
INSTALLATION DETAILS, HD MR J ROSOWSKI
Title: Dote:
HORIZONTAL ROLLER WINDOW DETAILS 12/01/11
Sertea/Model: Scale: Sheet: Dmwing No. Rev:
HR-210 NTS 6 OF 8 MD-HR210-01
1/8" ANNEALED OR
/711 TEMPERED GLASS wplyins with 11w
1 1 1 il 817 0 q
8 i
40 90 Date 12-
40 NOA0
1 8--\cP ct('Ojllrol
27 GLASS BITE
rl 81
40
28 10 1/8" GLAZING DETAIL
3: C—)
o 9
3/16"ANNEALED OR 114"ANNEALED OR C)
TEMPERED GLASS
3 26 6 TEMPERED GLASS o
12 5 jjil 91 r
11 .382" MIN..382"MIN.
LLI C
GLASS
BITE GLASS SITE 81 (n co
T u-
0
3/16" GLAZING DETAIL 1/4" GLAZING DETAIL —1 06
2 40 U)
112"MIN, M �—
0 FRAME 40 2 0 z
SASH MEETING GLASS STACK LLJ W
26 CORNERS CORNERS RAIL -j
1/8'ANNEALED OR 114"AIRSPACE V)
118"ANNEALED OR
TEMPERED GLASS F ASSEMBLY DETAILS TEMPERED GLASS 0 CV
57 93 Lu
Z C>
II
Iz kw N j CL
W
.382"MIN. 0
GLASS BITE 81 10 x;
(3 ILL ADAPTER
11 53
it 1/2" I.G. GLAZING DETAIL
3 1/4"AIRSPACE
0
Z1,
112. MIN.
GLASS STACK
.250" .3 o" 3116"ANNEALED OR 3116"AIRSPACE
TEMPERED GLASS 118" ANNEALED OR
TEMPERED GLASS
.180" .416"
94 ...........
fr 1.200-
WEEPHOLE .382"MIN.
GLASS SITE
z :tua.. 1.600-- 81
2 Z
52 lu) — —A
C)
WEEPHOLE DETAILS
SILL C,2 co Z
O SHOWN WITHOUT WEEPHOLE COVERS.
SEE SHEET 1 FOR QUANTITY AND SPACING 1/2" I.G. GLAZING DETAIL ......
3116"AIRSPACE
4(
TARI F 7-
Item
Dwg#
Part#
Description
Material
1
215B
6215W
Frame Head
6063-T6
2
264
6264W
Frame Sill
6063-T5
3
265
6265BW
Sill Adapter.
606346
4 _
218A
6218W
Frame Jamb (Fixed)
6053-T6
5
219
61088W
Frame Jamb (Operable)
6063-T5
6
220B
6220W
Fixed Meeting Rail
6063-T6
7
267
0287W
Heavy Duty Fixed Meeting Rail
6063-T6
8
223A
6223W
Sash Top & Bottom Rail
6063-T6
9
223A
6223W
Sash Bottom Rail
6063-T6
10
221B
6221BW
Sash Side Rail
6063-T6
11
222
6222W
Sash Meeting Rail
6063-TG
12
270
6270W
Do bone Reinforcement
6063-T6
13
2765
62765W
Sash Stop _
6063-T5
20
4080
74060BK
Meeting Rail Sweep Latch Plug
Rigid PVC
21
242
42105W
Sash Top Guide (Anti -rack)
Rigid PVC
22
227
42114W
End Cap
Rigid PVC
.23
1213
6Q200K
.190" X.200" Won Wstp. (Frame)
Flex PVC 70
24
4066
64066G
.167" X.230" Fin Wstp.
26
1003C
76601K
Bulb Vinyl Wstp. (Sash)
Flex PVC 70
26
275C
70276CK
Frame Sill Gasket
Polyethylene
27
273A
70273AK
Frame Head Gasket
Polyethylene
28
280
1 70280BK
Sash Gaskets
Polyethylene
29
7HRKITW
Weephole Cofer
Plastic
30
1096
1 71096W
Sweep Latch
Cast Zinc
31
. 225
1 42112N
Roller Housing & Guide
Vinyl.
32
226
7BRWHL2
Roller
Brass
40
1155
781PQA
#8 X 1" QUAD Pn SMS.
Steel
41
11554
701PQX
#8 X 1" Sq. Pn. SMS
41O SS
42
7BiPSTX
#8 X 1" Sq. Pn. TWin Fast SMS
41O SS
43
7SX38PSA
#8 X.375" S . Pn. SMS
Steel
44
1016
7658VVW
#8 X.625" Ph. FI. SMS
Steel
50
1265.3
712653K
Setting Black 3/32" X 1/4" X 1"
EPDM
51 1
1267
1 71267N
Setting Block 1/8" X 1/2" X 1"
EPDM
52 1
16DURAK316
Duraseal - 3116" (IG only).
63
6DURAK14
Duraseal - 14' (IG only)
54
1625
61625W
1/8" Bead
Aluminum
55
2719
65016W
3/16" Bead _
Aluminum
56
1263
65133W
1/4" Bead
Aluminum
57
1253
6VT48W
I.G. Bead
Rigid PVC
70
1014
61014FW
Screen Frame
Aluminum
71
1631
47041 W
Screen Comer Key No Ring
Vinyl
72
1630
47042W
Screen Comer Key with Ring
Vinyl
73
320 1
7320SPNG
Screen Spring
Spring Steel
74
1524
61624K
Screen Spline - A 35" Die. Foam
Rubber
75
1635
61635K
Screen Spline - .135" Die. Hard
Rubber
76
Screen Cloth
Fiberglass
80
134
06615W
Add -on Flange (Optional)
1 606346
81
Dow Corning 899 Silicone Glazing Sealant or Equiv.
90
1/8" Annealed or Tempered Glass
91
3/18" Annealed or Tempered Glass
92
1/4" Annealed or Tempered Glass
93
1/8"- 1/4" Air - 1/8" An. or Temp. I.G.
94
1/8"- 3/16" Air - 3/16" An. or Temp. I.G.
2.000"
.050"
1.827"
L .050•
�- 2.000"
2.624"
OFRAME HEAD O FRAME SILL
6063-T6 ALUMINUM 6053-T5 ALUMINUM
1.682°
1.010"
.082" - 1
OFIXED MEETING RAIL
6063-T6 ALUMINUM
.062'
2.428"
1.542" --�-I
.062"
2.124"
1.542"
.062"
2.209"
OSILLADAPTER FRAME JAMB
FRAME 1AMB
8063 TB ALUMINUM O 6063- 6A UM NIUM 1 O 60 3 T5 ALUMINUM-BLII------N1
i`
OHD FIXED MEETING RAIL O SASH TOP & BOTTOM RAIL
6063-TB ALUMINUM 606346 ALUMINUM
1- 1.114"
I
.761'
.asz" 1-
12 DOGBONE REINFORCEMENT 13 SASH STOP
6083-T6 ALUMINUM 6063-T5 ALUMINUM
i
,�11111111 I,r,.
r =
W_
FLOE;...
�' �,FSS IONP�' �•�•
A. LYNN MILLER, P.E.
PAR 58705
I'7Tr .050"
.050"� yIL
ADDON FLANGE
80 6063-T6 ALUMINUM
W_ "IceiTll
r- 1.816,
.093" '062"
1.605"
10 SASH SIDE RAIL
6063-T6 ALUMINUM
1.749"
1.457°
.062"
11 SASH MEETING RAIL .
6063-T6 ALUMINUM
Approved as complying with the
Floridluildh oda
Dale Q/o 2
Revielon: NO
1' o¢
etnl MIMI
Revrelon: BY -
I BOM & PART DETAILS I J ROSOWSKI I
1070 TECHNOLOGY DRIVE Titre: oats:
N. VENICE, FL 34275 HORIZONTAL ROLLER WINDOW DETAILS 12/01/11
P.O. BOX 1529
NOKOMIS,' FL 34274 Seriee/Modal: Scale: Shoat: Growing No. Rev:
CERT. OF AUTH. #29286 HR-210 NTS 8 OF 8 MD-HR210-01
-.e«„FM Ung"T
'
'A & �wfi
..�.. �..:�.,..z,.:e:��`� �, � a�.,.:.��.,.c,.....�...�........._....,....,.::w.u�.s s� �s •� � � i2.����h1 °��s?.�.:5=?z�:. uw"mu: �a._.i�.�sfs.
ri l: - e s? BCIS Home Log. In -User Registration Hot Topics Submit Surcharge Stats &Facts "gyPublications FBC Staff BCIS Site Map Links Search
ipp. w� El.
g,(,
rofessi �0�q;Product Approval
USER:Public User
Produr: A ; r;.ae: h'.enu > P: r.,^u�r nr a;I;.Illicati�ar: Sea > 'A "OrmGran_?, st > Application Detail
—.... L.n --.._..._.... ._...._...._..._.._.... __..__....._. .__.
s FL # FL161-R4
F Application Type :Revision
Code Version 2010 {
Application Status Approved I.
13
Comments
Archived
Product Manufacturer Custom Window Systems Inc.
Address/Phone/Email 1900 SW 44th Avenue
Ocala, FL 34474
(352) 368-6922 Ext.207
mlafevre@cws.cc
Authorized Signature Michael LaFevre
mlafevre@cws.cc
Technical Representative
Address/Phone/Email
Brian Tenace
1906 SW 44th Ave.
Ocala; FL 34474
(352) 368-6922 Ext 291
btenace@cws.cc
Quality Assurance Representative
Jeff Thompson
Address/Phone/Email
1900 SW 44th Ave.
Ocala, FL 34474
(352) 368-6922 Ext221
jhompson@cws.,cc
CategoryExterior.
Doors
s
Subcategory
*SwinginglEztenor'Door.Assel Mies
Compliance Method
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
€ 'Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who
developed the Evaluation Report
Florida License
Quality Assurance. Entity
Quality Assurance Contract Expiration Date
'Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Lucas A. Turner
PE-58201:
Keystone Certifications, Inc.
03/01/2014
Steven M. Urich, PE
Validation Checklist - Hardcopy-Received
FL161. R4 COI EvaiReo CWS-176C (Guardian Door).odf
Standard Year
AAMA/101/I.S.2-97 1997
ASTM E 1300-04 2004
http://www.floridabuilaing.org/pr/Pr app dtl.aspx`?
param=WGEVXQwtDqvyf4ngAXh10... 10/31 /2012
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
12/01/2011
Date Validated
12/16/2011
Date Pending FBC Approval
12/21/20.11
Date Approved
01/31/2012
;Summary of Products
............... _.............. _... __.- ............. ..... _..:
FL #
N�odel;;Number.or Name
Description
d6i1!1
Guardeni:Hin etJDoor
Guardian .Hinged Door w/ Glazed Insert (Operable or
Fixed):
Limits of Use .
Installation Instructions
.Approved for use in HVHZ: No
FL161 R4 II CWS-176C (Guardian Door).odf
Approved for use •outside HVHZ: Yes
Verified By.: Lucas A. Turner 58201
Impact Resistants Nb- a r .
Created by -Independent Third Party: Yes
Design Pressure: +40/�,40
/,j-
Evaluation Reports
Other: Not for.use in HVHZ. .Primartly used with Screen .
Fia.67. R4 AE Fvi!Reo CWS-176C Gkia-diari Do•,r) Ddf
Rooms. 1 1. .
I Created by Independent Third Party: Yes
161.2 Guardian Hinged Door
IGuardian,Hinged Door w/ Solid Core.
Limits of Use
Installation Instructions
Approved for use in •HVHZ: No
FL161 R4 TIno ai-ass) nd
Approved'for use outside HVHZ: Yes
Verified By: Lucas A. Turner 58201
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +40/-40
Evaluation Reports
Other: Not for use in HVHZ. Primarily used with Screen
cL1.61. R4 AE -EvaiReo CWS-242B Guardian Door no
11ass'.pdf
Rooms.
Created by Independent Third Party: Yes
�Eii+Cl: fYext
,Contact Us ::.1940 North Monroe Street. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. _Copyright 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you donot want your a -mall address released in response to a public -records request, do not
send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850,487.1395.
*Pursuant to.Section 455.275(1), Florida Statutes, effective October 1,.2012, licensees licensed under Chapter 455,-F..S. must provide the Department
with an email address if they have one. The emails provided may be used for official communication withthelicensee. However�email addresses are public
record. If you do not wish to -supply a personal address, please provide the Department with an email address which can be made available to'the public.
To determine. If you are a licensee under Chapter 455,. F.S.,,please click here .
.Product Approval Accepts:
http://www.floridabuilding. org/pr/pr_app_dtl.aspx?pararn=wGEVXQwtDgvyf4ngAXhl O... 10/31 /2012
PRIME DOOR ELEVATION. (NON -IMPACT) ALUMINUM NON -IMPACT REQUIREMENT: - -
1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE FLORIDA BUILDING CODE, CURRENT
37 25.Q EDITION.
OVERALL WIDTH I. 2. GLAZING OPTIONS: (SEE SHEET 3)
OPENING
FRAME O3. CONFIGURATIONS; OUTSWING, LEFT OR RIGHT HINGED.
35" . 4. ANCHORAGE: THE 33 113% STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT. SEE SHEETS 6-7 FOR
OR CORE ANCHOR DETAIL, WINDLOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS.
A 5. DESIGN PRESSURE RATING (SEE BELOW):
-NEGATIVE DESIGN LOADS BASED ON.TESTED PRESSURE AND GLASS TABLES ASTM E 1300.
-POSITIVE DESIGN LOADS BASED ON TESTED PRESSURE, WATER INFILTRATION TEST PRESSURE AND GLASS TABLES ASTM E 1300.
6. NOT APPROVED FOR IMPACT RESISTANCE. IMPACT PROTECTIVE SYSTEM IS REQUIRED IN WIND BORNE DEBRIS REGION.
7 5/8"
HINGE 7. ALL FRAMES SCREWED TOGETHER. SMALL JOINT SEAM SEALANT USED AT ALL FRAME JOINTS.
3�14" I 81.000 B. REFERENCE TEST REPORTS: NCTL-210-3251-1
I
OVERALL_ - - _ 9, 1X OR 2X WOOD BUCK OR STUD FRAMING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE.
HEIGHT " BUCK AND FRAMING IS RESPONSIBILITY OFARCHITECT OR ENGINEER OF RECORD. PORCH ENCLOSURE MEMBERS SHALL BE 6063-T5
72 ALUMINUM MINIMUM WITKMINIMUM WALL THICKNESS OF 0.045". STRUCTURAL INTEGRITY OF PORCH ENCLOSURE TO RECEIVE APPLIED
HINGE LOADS FROM WINDOWS SHALL BE VERIFIED BY OTHERS.
B I R.
60"
FRAME
OPENING
HEIGHT
4 7/16" lwn
� I
DOOR i 1
CORE, I DESIGN PRESSURE RATING
zz HINGE ±40.0 PSF
7 5/B"
HINGE
C UPDATED PER 2010 FBC 10/17/11 TEF
A LUCAS A. TURNER, FL P.E. 58201 B. ADDED VENDOR COLUMN TO PARTS LIST 03/13/09
`�.�^� ptPJRESR�I� i��� /n/_',.�___•
."m31NINDUWS &.DOORS
TABLE OF CONTENTS
z v : Na 59201 11 1900 SW 44TH.AVE.
GENERAL NOTES ................. :... F; * ;,� = OCALA, FLORIDA 34474
.1
ANCHOR SCHEDULE & NOTES .......... 2 LwaaTmre,,P,E 2011-11-3019:04-05:00
GLAZING DETAIL.................................3 i 1t S'i'AT'L OF .'t GENERAL NOTES
SECTION VIEWS..................................4 :O QIfi 37:7: F.ritid:dP.'CJE,
Tf'L?
EXTRUSIONS S, B'.O.M....................... .5 PROPRIETARYAND CONFIDENTWL 11/30/11 '"'r •.F, -,A 21 1000 A03/13/2009
INSTALLATION DETAIL.....................6-7 C O R 14' .� C
WRITTENPERWINDOW MSSIONOFCUSTOMWINDOWSIYSTEMS OASA WHOLE R
IS PROHIBITED. HOUiTHE �����5 ���'Aii 5,� ��� 1- �L GUARDIAN DOOR tFV `Yi, NT11," iJ` CWS-176
1 OF 7
12 3/4" MAX. O.C:
6 MAX
E MAX:
17" MAX O.C:
INSTALL ONE #10 ANCHOR THRU
EACH HINGE INTO SUBSTRATE
(SEE SHTS 6.7)
NOTES:
1. INSTALL ONE ANCHOR AT EACH LOCATION.. SILL ANCHOR.SPACING SAME AS HEAD:
2. SHIM AS.REQ'D AT INSTALLATION ANCHOR USING LOAD BEARING SHIMS. 'MAX ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE
GREATER THAN 1/16" IS PRESENT. -
3. LOAD,BEARING SHIMS SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. WOOD SHIMS ARE NOT ALLOWED.
4. 3116 DIA: ELCO ULTRACON MASONRY ANCHORS MUST BE OF SUFFICIENT LENGTH TO ACHIEVE A MIN. EMBEDMENT OF 1 1/4" INTO MASONRY
THRU FRAME OR THRU 1 BY WOOD BUCK INTO MASONRY.. A MINIMUM EDGE DISTANCE OF 2 1/2", IN ANY DIRECTION, SHALL BE ACHIEVED.
5. #10 WOOD SCREW ANCHORS THRU FLANGE MUST BE OF SUFFICIENT LENGTH TO ACHIEVE A MIN. EMBEDMENT OF 1 1/2" INTO 2 BY WOOD
BUCK. A MINIMUM EDGE DISTANCE OF 5116", IN ANY DIRECTION, SHALL BE ACHIEVED.
6. #8 OR STRONGER WOOD SCREW ANCHORS THRU HINGE OR LOCKIDEADBOLT STRIKES MUST BE OF SUFFICIENT LENGTH TO ACHIEVE A MIN.
EMBEDMENT OF 1 318" INTO 2 BY WOOD BUCK: A MIN. EDGE DISTANCE OF 1/2" SHALL BE ACHIEVED IN EITHER DIRECTION.
7. #10 SMS ANCHORS MUST BE OF SUFFICIENT LENGTH TO ACHIEVE A MIN. PENETRATION OF THREE THREADS BEYOND ANCHOR PLATE SURFACE
IN TUBE FRAME INSTALLATION. -
8. GLAZED WINDOW FRAMEATTACHED TO DOOR LEAF OPENING, IN ACCORDANCE WITH STRUCTURAL PERFORMANCE TEST REPORT
NCTL-210-3251.1. ALL GLAZING IS TEMPERED GLASS ONLY. -
9. SEAL. CORNERS WITH SMALL JOINT SEAM SEALANT.
10. ALL INSTALLATION ANCHORS MUST BE MADE OF OR COATED WITH A CORROSION RESISTANT MATERIAL. DISSIMILAR MATERIALS OR
MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST BE PROTECTED TO PREVENT REACTIONS.
11. INSTALLATION ANCHORS SHALL BE IN ACCORDANCE. WITH. ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL_
NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW.
12. INSTALLATION ANCHOR CAPACITIES FOR PRODUCTS. HEREIN ARE BASED ON SUBSTRATE MATERIAL WITH THE FOLLOWING PROPERTIES:
A: WOOD- MINIMUM SPECIFIC GRAVITY OF G=0.55 (SOUTHERN PINE OR GREATER)
B. CONCRETE -MINIMUM COMPRESSIVE STRENGTH OF 3,200PSI.
C. MASONRY- STRENGTH CONFORMANCE TO ASTM C-90, GRADE N, TYPE 1 (OR GREATER):
D: ALUMINUM - 6063•T5 (OR GREATER)
13. SEALING AND FLASHING. STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS IN ACCORDANCE .
WITH THE CURRENT VERSION OF THE FOLLOWING REFERENCE DOCUMENTS:
FMA/AAMA 100 (FIN WINDOWS), FMA/AAMA 200 (FLANGE WINDOWS), FMANVOMA 250 (BOX WINDOWS), PROPRIETARYAN6 CONFIDENTIAL 11/36/11
FMA/AAMA/WDMA 300(EXTERIOR DOORS). THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CUSTOM
WINDOW SYSTEMS. INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE
WRITTEN PERMISSION OF CUSTOM WINDOW SYSTEMS. INC. IS PROHIBITED.
INSTALLATION ANCHOR, TYP.
(SEE NOTE 2)
INSTALL TWO #10 ANCHORS THRU
STRIKE PLATE AND DEADBOU STRIKE=
PLATE INTO SUBSTRATE (SEE SHTS 6,
GLAZED WINDOW FRAME
(SEE NOTE 7)
ANCHOR LAYOUT - (FLANGE)
LUCAS A. TURNER, FL P.E.
10/17/11 TEF
26 7116" .
MAX FRAME WIDTH
— 24 9/16' -
MAX DLO W IDTH-
27 11/16"
MAX
DLO
HEIGHT -
58 L5/16_'
--
MAX
FRAME
/�
HEIGHT
• �
26 7/8'
MAX
DLO
HEIGHT
23" —.
MAX DLO WIDTH
FULL VIEW
SINGLE HUNG
ALL GLAZING (FIXED & SASH)
TEMPERED GLASS ONLY
z�
PROPRIETARYAND CONFIDENTIAL ISI3O/I1
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CUSTOM
WINDOW SYSTEMS, INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE
WRITTEN PERMISSION OF CUSTOM WINDOW SYSTEMS, INC. IS PROHIBITED.
C UPDATED PER 2010 FBC 10l17/11 TEF
LUCAS A. TURNER, FL P.E. 58201 B ADDED VENDOR COLUMN TO PARTS LIST 03/13/09
�������t 117RE ty �� i��� �.•�_-_•
t 9 i✓ '+. �6..LLlLLV�z
IMINDOWS & DOORS .
N. 58201 : n 1900 SW 44TH AVE.
i :,i = OCALA, FLORIDA 34474
AIDE 03/13/2009
NTS ' CWS-176
EF C ;tn_gT 3 OF 7
IN'
E:
SECTION B-13
Q7 NOTE: ITEMS NOT SHOWN FOR CLARITY1
11,3,5,7,9,11,17-19,21,22,24-31,36,37
TTC UPDATED PER 2010 FBC 10117111 TEF'
LUCAS A. TURNER, FL P.E. 5812.01 B ADDED VENDOR COLUMN To PARTS. LIST 03113/09,
ALT. THRESHOLD (1186) ALT. -THRESHOLD (1126)-
4
ORS
No 58201 1900 SW 44TH AVE.
(1193)
OCALA, FLORIDA 34474
1 IT I.E., SECTION VIEWS
C
6 rA-1 9 OF itlj I --
.0.
PROPRIETARYAND CONFIDENTIAL . 11/30/11 1000 ADE 1` 03/13/2009
SECTION A -A THE INFORMATION CONTAINED IN THIS DRAWINS IS THE SOLE PROPERTY OF CUSTOM 0 R . k .
'S' 151. •
1 ....
WINDOW GUARDIAN DOOR
YSTEMS. INC. ANY REPRODUCTION INFANT ORAS A WHOLE WITHOUT THE "ift /ONM-l-' -
WRITTEN PERMISSION OF CUSTOMWINDOW SYSTEMS. INC. IS PROHIBITED. 111116111111%, — llPv.LET-T-P c --Hl" 4
- f A Oc 7
ITEM#
CWS#
DESCRIPTION..
VENDOR
MATERIAL
1
S-1377
HEAD, Z BAR, OUTSWING -
KEYMARK
ALUM
"3
S-1374 ]JAM
KEYMARK
ALUM
" 5
S-1186
THRESHOLD
KEYMARK
ALUM "
6.
S-1193 ]SADDLE
THRESHOLD
KEYMARK
ALUM
.7 _
S-1126
I BUMPER THRESHOLD
KEYMARK
ALUM
_ B
H-1001
DOORCORE
KEYMARK.
ALUM
.9.
S-1002_
CORNER KEY
KEYMARK
ALUM
10
P-3008
HINGES
IDEAL
SS
11
, P-3376
POP RIVET
HUB.
SS
12
P-3280
DEADBOLT-3127-AfQ
DELANEY
SS
13._
P-3280:,
LOCKSET-3127-ArQ
DELANEY
SS .
14
P-3302,
WSTP, .330 x.187 FIN, BLACK SOFT TOUCH
ULTRAFAB .
" 15.
P-3310
WSTP, .350 xA 87 BULB VINYL
ULTRAFAB
17
1 P-3087
IGASKET, DOOR KNOB
PRATT IND.
FOAM
18
1 P-3204.
GASKET,DEADBOLT
HOPRODUCTS
FOAM
19
P-3584
IFOAM CORE
ELITE "
24 .
P-3539
8 x3/4; QUAD PAN TEK
FASTEC
STEEL
25 _
P-3329,
IFOAM BLOCK, DOOR KNOB :
IMPERIAL •
FOAM.
26
P-3350
FOAM BLOCK, FILLER
METALS USA
28
. P-3369
CYLINDER, DOOR PLUNGER
YALE
SS
29
P-3370
CYLINDER, DEAD BOLT
YALE
SS
'31
P-3531
8x3/8PHILFLAT SMS.
FASTEC
SS
32
P-3214
BUGSWEEP
TEAMPLASTICS
PLASTIC
33
S-1300
ADJUSTABLE SWEEP
KEYMARK
ALUM
' 34
P,3367
DOOR STRIKE
YALE
SS .
35
33 P-68
DEADBOLT STRIKE
PALE
SS
36 -
P-3612
8 x 1-114 QUAD PAN W/ 1/4" LEAD ,
FASTEC _
STEEL "
37
1 P-3776 113ACKER
PLATE
ALCOA
ALUM
DOOR CORE - H-1001
CORNER KEY'- S-1002
6"
2 3/8"
--1 1/16"
C; 1 13/16"
OUTSWING HEAD SA377
2 3/8"
--1 1/16"
031 11116"
---j-
OUTSWING JAMB S-1374
1/16" --
905
BUMPER THRESHOLD S-1126
ALL ALUMINUM EXTRUSIONS ARE 6063-T6
2 518"
..1/16"
C3 1 3/1G'
ADJUSTABLE SWEEP S-1300
3 7110"
�.
13/16"
—L
SADDLE THRESHOLD S-1193
-- 2 15116" --
1/16"
5
1 1/2"
STANDARD THRESHOLD S-1186
C UPDATED PER 2610 FBC
OUTER FRAME
ASSEMBLY
1
PANELFRAME
ASSEMBLY
'
LUCAS A. TURNER, FL P.E. 58201
B
ADDED VENDOR COLUMN TO PARTS LIST
"s^'O
G '.
L t17NDU11'S & DUORS
hao 582D7 :Ms
1900 SW 44TH AVE.
=
OCALA, FLORIDA 34474
"33 . STA16 OF 4t.^
C7 '.
EXTRUSIONS & B.O.M
T L 3:
PROPPoETARYAND CONFIDENTIAL 11/30/11
THE INFORMATION CONTAINED THIS DRAWING
4! C
♦iT ��:</ CAA =��'
I: 1 ' \
'RASNIN BY:
1000 ADE
';t I L.
GUARDIAN DOOR
:*i::AL='
NTC
IN IS THE SOLE PROPERTY OF CUSTOM
WHOLE THE
N FCUSTOMW1NDOWSy
t , ��
�l't��5r0ir A„` ��
WRITTEN PERh93SI0S. OC.
TER'O�ASS
PROHIBITED.
-Y, �FTt
10/17/1.1 TEF
03/13/09
03/13/2009
o CWS-17G
50F7
1 1/2" MIN: EMBEDMENT MIN. EMBEDMENT [E]
[DI a v, > v c c d ' v " o SEALANT BETWEEN BUCK AND OPENING 2X
5/16" MIN. EDGE DIST.
[DI
BY OTHERS
WOOD FRAME/2X BUCK
BY OTHERS
INTERIOR
9 D 9 v
CONCRETE OR MASONRY o
v
5/16" MIN. EDGE DIST.
'[A]
1/4" MAX. SHIM
OPENING BY OTHERS. —
[B]
ID].. -
INSTALLATION ANCHOR,
INSTALLATION ANCHOR, -- -
#10 DIA. WOOD SCREW
1/2"
#10 DIA. WOOD SCREW
ANCHOR.
114" MAX.
ID)
!
ANCHOR.
SHIM MIN. EMBEDMENT
[D]
[DI
[BI
2X WOOD BUCK/WOOD FRAMING
BY OTHERS
�\
SEALANT BEHIND FLANGE
[A]
.
•
BY INSTALLER.'
HEAD .
'� `INSTALLATION ANCHOR,
1/2' / \ #8 WOOD SCREW THRU HINGE
(MIN. EDGE DIST.) IE] EXTERIOR FINISH (1 ANCHOR/HINGE) IE]
BY OTHERS. EXTERIOR
— —5/16" MINPERIMETER SEALANT. EDGE DIST. [D] BY INSTALLER.
' 1/4" MAX. SHIM [B]--.—_._._. _
EHINGE SIDE DETAIL
2X WOOD BUCW WOOD FRAMING
1 3/8".MIN. EMBEDMENT [E]
INTERIOR
2X WOOD FRAME/ 2X BUCK
BY OTHERS.
,f [A]
STRIKE PLATE SCREW .
EXTERIOR INTERIOR #6 WOOD SCREW (2/ STRIKE
21�:AND DEADBOIT STRIKE.. IE]
DOORFRAME:--
,^ SILL MIN. EMBEDMENT [D] REFERENCE NOTES:
EXTERIOR ! F (MIN. EDGE DIST.) IF] [A] SEE NOTE 9, SHT 1
INSTALLATION ANCHOR, IS] SEE NOTE 283; SHT 2
DIA. CONCRETE INSTALLATION ANCHOR, [DI
SEE NOTE 4. SHT 2
SCR SEE NOTE 5, SHT 2
[C]
SCREW ANCHOR. #10 DIA. WOOD SCREW [E] SEE NOTE 6, SHT 2
PERIMETER SEALANT
ANCHOR.
SEAL OR SET SILL IN
BY OTHERS.
[DI
-
CONCRETE OR MASONRY.
GLAZED WINDOW FRAME ATTACHMENT
EXTERIOR FINISH
. ?
(SEE NOTE 7, SHEET 2)
BY OTHERS.
C
UPDATED PER 2010 FBC
10117/l l TEF
PERIMETER SEALANT
BY INSTALLER,
D LOCKING SIDE DETAIL
LUCAS A. TURNER, FL P:E. 55201
gun ery,
B
ADDED VENDOR COLUMN TO PARTS LIST
03/13/09
6 2X-WOODBUCWWOODFWAMG
'v
4Tii)RE11�`
A F !V
'v
Gt'7.y�0
IIi7NDUN'S&DOORS
111LMIN.EMBEDMENT
,
°
CJ.• •1r.
[C] �— •
e
>
o
v • No 58201 : � �
1900 SW 44TH AVE.
v '
v
' v o
4, f ; 3t f
OCALA, FLORIDA 34474
CONCRETE OR MASONRY
*
I I
2 112" MIN. EDGE DIST.
BY OTHERS. zZS
M STATE OF
INSTALLATION DETAIL-
WOOD
[O]
�c1VERTICAL SECTION
PROPRIETARY
THE INFORMATION CONTAINED
O
+f,���cSFt O :; C� C%�,
1 DDO
BY:
ADE
03/13/2009
6
IN THIS IS THE SOLE PROPERTY OF CUSl Old
ANY REPRODUCTION IN
�'Q, /t%n1/�,
\ �,``
GUARDIAN DOOR
.a. so.
CWS-17G
;f'`
WRIVANTTEN PERMISSION OF CUSTOM WINDOW SYSTEC.
IS INC.IS P OH BITEDHOUTINE
ti,
ti ^TINT C
I i,
6OF7
a,
SCREEN ENCLOSURE
MEMBER BY OTHERS
[A]
INSTALLATION ANCHO
#10 SMS.
IF]
SEALANT BEHIND FLAP
FRAME
SCREEN ENCLOSURE --
MEMBER BY OTHERS
[A]
INSTALLATION ANCHOR,
#10 DIA. SMS ANCHOR.
IF]
1/4" MAX. SHIM
[B]
j DOORFRAME
JAMB INTERIOR
BYINSTALLER HEAD
SEALANT BEHIND FLANGE INSTALLATION ANCHOR,#8 SMS THRU HINGE EXTERIOR
BY INSTALLER \
BY OTHERS. (1 ANCHOR/HINGE) IF]
EXTERIOR FINISH `PERIMETER SEALANT
BY INSTALLER.
%H'� HINGE SIDE DETAIL
I\ 7 l ALUMINUNVSTEEL TUBE
— 114" MAX. SHIM
- [Bi
DOORFRAME
JAMB ---SCREEN ENCLOSURE
INTERIOR MEMBER BY OTHERS
[A]
EXTERIOR INTERIOR. "
—� - REFERENCE NOTES:
;—STRIKE PLATE SCREW '
#8 X 1 1/2" FH SMS IF] [Al SEE NOTE 9, SHT 1
[B] SEE NOTE 2&3, SHT 2
DOOR FRAME [C] SEE NOTE 4. SHT 2 _
,^ SILL _ [DJ SEE NOTE 5, SHT 2
[F] SEE NOTE 7, SHT 2
INSTALLATION ANCHOR;
#10 SMS ANCHOR
TALLATION ANCHOR, EXTERIOR IF]
R3"DIA. CONCRETE
--SEALANT BEHIND FLANGE
SCREW ANCHOR: -----BY INSTALLER
ICI
\ C UPDATED PER 2010 FBC 10/17/11 TEF
SEAL OR SET SILLS GLAZED WINDOW FRAME ATTACHMENT
CONCRETE OR MASONRY.' SEE NOTE 7, SHEET 2 "
\ ( ) LUCAS A. TURNER, FL P.E. 58201 B ADDED VENDOR COLUMN TO PARTS LIST 03/13/09
PERIMETER SEALANT— —
BY OTHERS. \ , v = ` 171 LOCKING
M sD ELDE FAIL ,� �F s1DRE11,' !oe,
* �•: \ ' ^ • •�117NDOWS & DOORS
s' No 5920'1 : cs : 1900 SW 44TH AVE.
7 1/4 MIN: EMBEDMENT
[Cyr Y
CONCRETE OR MASONRY
v # ti OCALA, FLORIDA 34474
rr t v • v v F v� v xo = BY OTHERS. `I INSTALLATION DETAIL -ALUMINUM TUBE
I f 13 S1'KTC OF ltr
2 10 MIN. EDGE DIST. MC'n , V+r dN Bv. r TPROP' 03/1312009
'ICI THE INFORMATION CONTAIN D IIN�THIS ORAWIN G IETARYAND -THE SOLE PROPERTY OF CUUSTOM ���ir s / O R_1 .� � r� „.; 1000 CA Y AIDE
/ Y�VERTICALSECTION. .WINDOWSYSTEMS.IC.ANYREPRODUCTIONINPARTORA$AWHOLEWITHOUTTHE f� �� F� GUARDIAN DOOR NTS CW$-178
WRITTEN PERMISSION OF CUSTOM WINDOW SYSTEMS, INC. IS PROHIBITED. �illlU�]A1�r�T,,
. liirn=4td iEL<. i.ETTiR C
'' 7OF7
Scale:
M � rCor"y
\
Cat III sunroom under
existing truss .roof and r 1 a3ra"
CBS Home structure
3 0" --J (l
1 5 6-1/2" I — H s' 0-1/2^ �{
KC
GFI for
anc
1
2
L
\
�
D
.3
-
610-112
m
......
701.
?,. -...
...
......
...1'91%4
----
%ISIlIl. PROPOSED FORK
ARE SA -A f TO ANY CORRECTIONS
PE0010 ICY RI9LO INSPECTORS THAT
MAI NE NECESSARY IN ORDER TO
---�- Inw r-RS ORATTACHMEgS
AHE THE RESPONS1B10OFTHE
COMCTORORECOM
Windows and Doors
HR210 Horizontal Slider PGT
FL#242-R14
Guardian Hinged Door
Custom .Wi ndow Systems
FL#1614-R4
These are both non -impact -
items
Design pressures for the openings
are in the permit packet
3' 0.. 5 7-3/4' �i & 0-1/2" S� / OQ
x 3 and 2 x 3 attachment to
g4" 8'T' I-oststructure-see detail c2-4 ST. LUCIE COUNTY
BUILDING DIY N
REVIE
.0 CE
REVIEWS
DATE , zQ ,
Upright to concrete PLANS ND PERMIT
See Detail C'I -4 MUST BE EPT ON JOB OR
NO INSPECTION WILL BE MADE -
Site Address: 6690 Lila Ct, Ft Pierce, Spanish Lakes Fairways
1 /4=1 Design Criteria: Cat I I I Sunroom, Velocity Zone: 150 MPH, Exposure B
C
O
U
o
C/)�
O N
U �
L
Q
•E
_=
Q 3:
O �.
U —
U-
5-4
s. (V `
U0)
oU E�
C � 0
Z�
0,0 W J
U)
COt
0.
� 0-
Sheet #
1
of 1