Loading...
HomeMy WebLinkAboutSUBMITTED PAPERS416 Planning Development Services Department Building &_ Code: Regulation Division SC BNNE® . 2300 Virginia Avenue Ft. Pierce, FL 34982-5652 `St• LUCfe Cpun ty Te1:772-462-1553 -. APPL)ICATION FOR. ROOF PERMIT /� �l• ./ WEE REVERSE -SIDE FOR INSTRUCTIONS 1. Location/Site Address.: 2. Parcel ID Number: 3 _ 1 7 15 3 0 - D� Office Use' Section : Townshi - Ran a Ma e i i -• Only ud.Use. 3nitia 3.. Description of Projector. Work Activity:y ,E�, �C i��-Tq 4. Total Roof Area (square feet):. .25. Roof.Pitch: 6: Type of.Roof [ ] Fiberglass Shingle N' Concrete Roof Tile [: - ] Wood Shake] Shingle [ . ] Tar & Gravel (_ ]-Modified Bitumen ' . ( ] . O.ther [ ] Product Approval required -for all types of Roofing_ Material (2 Sets) _ : Al [ All Commercial Roofing :requires design by an Engineer or Architect (2 Seets) with Product Approval attached ** Roof Mitigation per F.S: . 553.844 will be required 7.. Owner. Information r. 8. Contractor Information FL- Reg/Cert #: / ll Address: l�l �_ A 'A ,u a �4-u L)_ County Cert #: City:,' �- .. States Business Name:' Zip: Phone:? 7.Z Z-o 1 7 ys Z_ Cell Phone: 9. Value of Construction: **Note Diy4n and Final Inspection Required._ Additional inspection -may. be required per Product Approval. CONTRACTOR/OWNER'SRFFIDAVIT: . .I certify that all of the information contained.in this application is correct and that all work will be done in compli with all applicable laws regulating construction and zoning. - a ava\ a: �vtlau•ac�/vF 1\c1.ti71\nl�llj1 STATE OF FLORIDA, COX 'P_ ACKNOWLEDGED BEFORE ME THIS DAY OF WHO PERSONALLY OWN_ TO O PRO UCED QUALIFIEB/Q R Z4. �.. ANGELA K HUFF. - l A :+__ MY COMMISSION NEE 083530 ,OTAR 7.. 3 EXPIRES: April 12, 2015 Bond edThru.Not.9 PublfcUndenvdters COINMISSION NUMBER NOTICE TO OWNER: FAILURE TO RECORD A.NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR DWROVEMENTSIO YOUR PROPERTY. IF YOU INTEND TO OBTAIN -FINANCING, CONSULT YOUR LENDER OR ' ATTORNEY BEFORE RECORDING YOUR NOTICE OF: COMMENCEMENT. Revised.4/26/2010' . To: SLC Building Page 1 of 1 2012-11-19 18:37:59 (GMT) 18888691058 From: Robert P. Dudley r"" r Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue. Fort Piercer FL 34982 772-462-2165 or 772-462-2172 Fax: 772-462-6443 ROOF INSPECTION AFFIDAVIT Re: Permit # I L-11 00 & b I, _ Yvonne P. Dudley , licensed as a(n)Contractor*/Engineer/Architect (Please print. name & circle license type) *FS468 Building Inspector *General, Building, Residential or Roorng Contractor or any individual cPrtifred under 468 F.S. to make such on inspection. On or about 11 / 15 / 2 Q U^ I did personally inspect the roof deck nailing (Date) workat. 121 NE Narania Ave.Pt.St.Lucie FL 34983 (job site address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S.) Signature and seal STATE OF FLORIDA COUNTY OF 3j--.1. CRC058551 License # Sworn to and subscribed before me this day of !" 0 a 0 k 201 by °an,e,u.�_k_�a Who 15 personally known to me or who has produced D ' � `4 .._ as identification. Notary Public, State of FI Signature of Notary: Commission Number! C 0 0 `3 Y (Seat) En 01/19/2011 ROBERT ALTINO My COMMISSION # EE081594 EXPIRES April 24, 2015 d98b151 .cam TICE OF COMMENCEMENT Permit No. Tax Folio No. State of Florida County of St. Lucie The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided inIthis Notice of Commencement. (and street address if General description of improvement: r Owner information or Lessee in€ rmation 1 the Lessee contracted for the improvement: Address I Z Interest in property:�- Name and address of fee simple titleholder (if different from Owner listed above): Contractor's Name: Contractor Address: Phone Number: Surety (if applicable, a copy of the payment bond is attached): Amount of bond: $ Phone number: Name and address: _ Lender Name: Phone Number: Lender's address: Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Sectiol 713.13(1)(a)7., Florida Statutes: Phone Number: Name: Address: In addition to himself or herself, Owner designates of Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Phone number of person or entity designated by owner: to receive a copy of i Expiration date of notice of commencement: (the expiration date may not be before the completion of construction and final payment t contractor, but will be 1 year from the date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.,A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. ;D0-nCl) C- 1-11M�> ��M—c) Xo�rn o v �C P,0)rn a, �, m u) 6cs� oy 'o-� Cx Z " a�rC,', N rn a y ;U p rJ 0 w 'n U A °m m m � -r C7 i� c: 0 0 C x� Under penalt of perjury, 1 declare that I have read the foregoing notice of commencement and that the facts stated therein are true to the best of my knowledge d belief. 9 or Lessee, or er's or Lessee's Authorized Officer/.Director/Partner/Manager (Signatory's Title/Office) / , / was acknowledged before me this day of —AL) , 20J, v The foregoing instrument --- By � �CJ as 0 �Qfor _ Name of Person Type of authority (e.g.officer,trustee) Parry on behalf of whom instrument was executied (Signature of tary Public - State of Flonca) It (Print, Type, or tamp Commissioned Name of Notary Public) Personally known,_or produced Identification Type of Identification produced ---------- buy ANGELAM.HUFF Foil.. '* ^ MEXPES:RapN�#iiEaoi,_ St. Lucie.Coun� Building & Zoning.Department 2300 Virginia Avenue Fort Pierce, Florida 34982 (772)462-1553' OWNER/BUILDER. AFFIDAVIT DISCLOSURE STATEMENT F.S. 489.103 (7) EXEMPTIONS - State -law -re quires -construction -to be -done-by-licensed­contractors. -You have applied for a permif under an exemption to that law: The°exemption allows you, as the owner of your propeity, to act as your own contractor even though, you do not have a license. You must provide direct, on site supervision of the construction yourself. You ;may a -or-improve;farm-butbuildings, a-oue-fariuly or two-family residence or a-commerc al building of a cost of under $75,000.00. The building or residence must be for your own occupancy. It may not be built or substantially improved for sale or lease. If -you sell or lease. a building you.have;built or substantially.improved-your self -within one-year after the construction is complete; the law will.presume that you built or. substantially improved it for sale _or lease which is a -violation of this. exemption. You may not -hire -an -unlicensed person .to act.as-your contractor -or to supervise people working on your.building; it is your responsibility to nake'sure that people employed by you have licenses-required_by state law and by county or municipal licensing ordinances. You may not delegate the _responsibility for supervising work to_.a:Iicensed -contractor- -who. not-licensed--to-perform-the-work-being-done:- Any person working on your, building": who is .not licensed must work under, your direct supervision and must be employed by_.you., which means that `-you.. must deduct FI.C.A. and. -withholding tax and provide workers' ---.-- compensation -for -that -employee, all-asprescribed_by_law_Your construction must=comply with_ahI-ap c` ab;-= ordinances, building codes, and zoning regulations. �tial I understand that the building official and.inspectors are not there to design or,give advice. on 4owtQmeet the minimum code. Initial I understand that as an owner -builder that any -contract disputes with sub -contractors and I must -be handled in a civil court with the advice of an attorney. This department will not mitigate any contract disputes. Initial . I understand .that if I compensate any person or company for work performed they are required to be licensed in this jurisdiction. If for some reason they do not -possess a license, I maybe responsible and liabl for the cost of the license. Initial I understand that if any person that is unlicensed and uninsured gets injured on .my construction project - they maybe entitled to workmen's compensation. I could, beheld liable for all doctor, lawyer and related medical cost, which could include loss of wages during recovery from their injury. Initial/ To qualify for this exemption under thissubsection, an owner must personally appear and sign the building_ permitapplicationand initial the above. I hereby acknowledge that I have read and understand the above disclosure statement and that I further understand that any violation of the terms of the owner/builder exemption shall be reported by the. -Building and Zoning Depar in to the Florida State Department of Professional Regulation.: ed and acknowledged on this day of of 20. caner ilder Sil >tdre F STATE OF FLOR COUNTYOF Z_U, 'UI The forzgoing instrument was act owied ed before me this day of �Du , ?0� by Gam. who is personally known ' to me, or who has pro uced as identification. I OVI ANGELAM.HUFF MY COMMISSION k EE 083530 Signature of N Type or Print ame of Notary =' Pry .r(q�.p� RES: April 12, 2015 Title: Notary Public Commission Number ,R 8bnaed7Ha Notary Public Underwriters a ROOF ASSEMF AND ROOFTOP STRUCTURES PCz c 4 111"zi LIE $LhLhLh 'v SECTION 1525 URRICANE ZONES UNIFORM PERMIT APPLICATION Florida Building Code Edition 2010 High -Velocity Hurricane Zone Uniform Permit Application Form. INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING PERMIT APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A,B,C 1,2,3,4,5,6,7 Prescriptive BUR-RAS 150 A,B,C 4,5,6,7 Asphaltic Shingles A,B,D 1,2,4,5,6,7 Ge terete-ell Clay Tile ,B,D,E 1,2,3,4,5,6,7 Metal Roofs A,B,D 1,2,3,4,5,6,7 Pr Wood Shingles and Shakes A,B,D 1,2,4;5,6,7 Po Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED: HARVEY E. KOEHNEN ffessional Engineer 32331: 7205 Elyse Circle St. Lucie, FL 34952-3212: (772) 489-3035 fax 1. Fire Directory Listing Page. / 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or If Applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation i 2010 FLORIDA BUILDING CODE — BUILDING 15.33 ROOF ASSEMBLIES AND ROOFTOP STRUCTUR! _ _., Master Permit No. Florida Building Code Edition 2010 High -Velocity Hurricane Zone Uniform Permit Application Form. Section A (General Information) Process No. Contractor's Name TW& DVpL_F_:1f D, 43. Job Address 2 NE N JA F A N 1A-, ROOF CATEGORY ❑ Low Slope ❑ Mechanically Fastened Tile lW Meftar/Adhesive Set Tile ❑ Asphaltic Shingles ❑ Metal Panel/Shingles ❑ Wood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 HARVEY E. KOEHNEN ROOF TYPE Profc-ssignal Engineer 32331 7205 Elyse Circle Poet St. Lucie, FL 34952-3212 I ❑ New Roof Reroofing ❑ Recovering ❑ Repair ❑(7�r�iE1t3fax ROOF SYSTEM INFORMATION •, Low Slope Roof Area (SF) Steep Sinned Roof Area (SF) ` Total (SF) ` I Section B (Roof Plan) .n i Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains.• Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. 15.34 w10 FLORIDA BUILDING CODE — BUILDING ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2010 High -Velocity Hurricane Zone Uniform Permit Application Form. r J t -- Section D'(Steep Sloped Roof System). Roof System Manufacturer: amrar gw z Notice of Acceptance Number: (( -- o,;I..24 o2 Minimum Design. Wind Pressures, If Applicable (From RAS 127 or . Calculations): 1: 'J_7`Z P2• ���� P3: -- E, . r i. NEiv Professional Engineer 32331 7205'Elyse Circle Fort St. Lucie, FL 34952,3292 Z772; 489-3036 fax Steep Sloped Roof System Description Deck Type; psi wood l%� Z" i� Type Underlayme.nt: �G�Y6►1e��5 �ol�fS'CI�t< Koh Roof Slope: 57: 121. Insulation: Fire Barrier: Ridge Ventilation? Fastener Type & Spacing: S6e:f9 Aa1rtR�t.��+ o1Joi+.M�C Adhesive Type: Ti 6 A. Type Cap Sheet: Mean Roof Height: 2,1 '`Co" Roof Covering: Kook -� LE i Type & Size 3 �, �. 266,!k• Drip Edge: ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2010 High -Velocity Hurricane Zone Uniform Permit Application Form. Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compare the values for Mr with the values from Mf. If the Mf values are greater than or equal to the Mr values, for each area of the roof, then the tile attachment method is acceptable. Method 1 "Moment Based Tile Calculations Per RAS 127" (Pl: x X _ ) - Mg: = Mrl Product Approval Mf (P2: x X _ ) - Mg: = K2 Product Approval Mf (P3: x)L _ ) Mg: = Mr3 . Product Approval Mf Method 2 "Simplified Tile Calculations Per Table Below" r Required Moment of Resistance (Mr) From Table Below 3A4__ Product Approval Mf Mr required Moment Resistance* Mean Roof Height --> Roof Slope 15, 20' 25' 30' 40' 2:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:1 28.4 30.1 31.6 ' 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7,12 24.4 25.9 27.1 28.2 30.0 *Must be used in conjunction with a list of moment based tile systems endorsed by the Broward County Board of Rules mdAppeMA.RVEY E. i OEHNEN Professional ;engineer 32831 / . For Uplift based tile systems use Method 3. Compared the values for Fwith the values for Fr. If the Fvalues are greater than or equal to the f ve Circle rcle for each area of the roof, then the tile attachment method is acceptable.,_L ua, F6_ 34952i212 Method 3 "Uplift Based Tile Calculations Per RAS 127" (PI: x L = x w: _ - W: x cos 0 = Frl Product Approval V (P2: x L = x w: = ) - W: x cos B = Fr2 Product Approval F' (P3: x L = x w: = ) - W: x cos B = Fri Product Approval F - f r• l'� Where to Obtain Information Description Symbol Where to find Design Pressure PI orP2orP3 RAS 127 Table I or by an engineering analysis prepared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope 0 Job Site Aerodynamic Multiplier A Product Approval Restoring Moment due to Gravity Mg Product Approval Attachment Resistance Mf Product Approval Required Moment Resistance Mo Calculated Minimum Attachment Resistance F' Product Approval Required Uplift Resistance Fr Calculated Average Tile. Weight W Product Approval Tile Dimensions = L length W = width Product Approval All calculations must bq submitted to the building official at the time of pertmt application. cocirlr.Y BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC) BOARD AND CODE ADMINISTRATION DIVISION MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F-(786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/building/ Clay Forever 6801 NW 72 Avenue Suite 301 Miami, FL 33166 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Section and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right -to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product. is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Andalusa Spanish "S" Clay Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of Building Official. HARVEY E. KOE9. HEN This renews NOA #06-0706.11 and consists of pages 1. through 5. Professional EnglnOer 32831 The submitted documentation was reviewed by Alex Tigera. 7206 Elyse Circle 7,I Port St. Lucie, FL 349,32-3212 /f (772) 489-ao3A No.:11- 224.02 MIAMI•DADE COUNTY l;acpiration a e• 3/15/16 Approval Date: 04/28/I1 Page 1 of 5 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub Category: Roofing Tiles Material: Clay 1. SCOPE: This approves a roofing system using Andalusa "S" Clay Tile, as manufactured by Sulacer in Cartes, Honduras and described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as detennined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION: Manufactured by Applicant Dimensions Andalusa "S" 1= 18.5" w = 11" Y thick Trim Pieces 1= varies w = varies varying thickness Test Product Specifications Description TAS 112 High profile clay roof tile. For direct deck adhesive set applications. TAS 112 2.1 EVIDENCE SUBMITTED: Test Agency Test Identifier IBA Consultants, Inc. 2354-27 IBA Consultants, Inc. MIAtyIIDADE COUNTY 2397-88 Accessory trim, concrete roof pieces for use at hips, rakes, ridges and valley terminations. Test Name/Report Date TAS 101 11/15/00 TAS 112 01/10/06 NOA No.:11-0224.02 Expiration Date: 03/15/16 , Approval Date: 04/28/11, Page 2 of 5 3. UmITATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with. TAS 106 may required, refer to applicable building code. 3.3 Applicant shall retain the services of a Miaini-Dade CountyCertified Laboratory to perform quarterly test in accordance with TAS 112, appendix. `A', Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4A herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 4. INSTALLATION: 4.1 Andalusa Spanish S Clay Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 120. 4.2 Data For Attachment Calculations Table 1; Average Weight (W) and Dimensions (I x w) Tile Profile Wei ht-W Ib Length - ! feet Width w feet Andalusa `S' Clay Tile 7.1 1.541 0.91 Table 2: Aerodynamic Multipliers - ft3 Tile Profile k (ft3) Batten Application X (fe) Direct Deck Application Andalusa 'S' Clay Tile N/A . 0.24 Table 3: Restoring Moments due to Gravity - M. (ft-lbf) Tile 2"•12" 3":12" 4"•12" 5"•12" 6":12" 7"•12" or Profile greater Andalusa 'Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct `S' Clay Deck Deck Deck Deck Deck Deck 1 N/A 3.97 N/A 3.91 N/A 3.84 N/A 3.70 N/A I 3.54 N/A 3.34 Tile NOA No.:11-0224.02 s�ii,ar�i•oaol=couNr�r Expiration Date: 03/15/16 Approval Date: 04/28/11 Page 3 of 5 i Table 7: Attachment Resistance Expressed as. a Moment - Mf (ft-lbf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistanc Flat Bermuda Concrete Tile Polyfoam PolyProTm 53.34 1 Large paddy placement of 76 grams of Pol Pro7m. 5. LABELING : All tiles shall bear the imprint or identifiable -marking of the manufacturer's name or logo (See Detail Below), or following statement: "Miami -Dade County Product Control Approved". ANIiALU SA MAD E ON Gil0NOU'A'AS � ANDALUSA "S" CLAY ROOF TILE (LOCATED ON TOP OF TILE) 6. Bi imNG PERNIIT REQUMEMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 this Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in orderto properly evaluate the installation of this system. NOA No.:11-0224.02 Expiration Date: 03/15/16 MtAfMtDAD; COUNTY Approval Date:. 04/28/11 Page 4 of 5 PROFILE DRAWING ANDALUSA 'S' CLAY ROOF TILE END OF THIS ACCEPTANCE NOA No.:11-0224.02 MIAMI•DADE COUNTY Expiration Date: 03/15/16 • Approval Date: 04/28/11 Page 5 of 5 MIAM I•DADE BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NO Polyfoam Products, Inc.. 11715 Boudreaux Road Tomball, TX 77375 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 209 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miantidade.gov/building/ SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control 'Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High VelocityHurricane Zone of the Florida Building Code. DESCRIPTION: PoIypro® AH160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the. user by the manufacturer or its distribi and shall be available for inspection at the job site at the request of the Building Official. o This renews NOA# 06-0201.02 and consists of pages l through 7. The submitted documentation was reviewed by Alex Tigera. MIAMbDADE COUNTX ,...w HARVEY E. KOEa- MEN :',rofoss6®na! Engineer 32331 � `I 7205 Elyse C ircSe Part 5t. Lucie, FL Z4,962-3212 (772) 433-3035 fax 1NUA 1NO.: 11-UU4.U4 Expiration Date: 05/10/12 Approval Date: 04/14/11 Page 1 of 7 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves Polypro® AH160 as manufactured by Polyfoam Products, Inc. as described in Section 2 of this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, does not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127, for use with approved flat, low, and high profile roof tiles system using Polypro® AH 160. Where the attachment calculations are done as a moment based system for single patty placement, and as an uplift based system for double patty systems PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product Description Specifications Polypro® AH160 N/A TAS 101 Two component polyurethane foam adhesive Foampro® RTF1000 N/A Dispensing Equipment ProPack® 30 & 100 N/A Dispensing Equipment PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list moment resistance values with the use of Polypro AH160 roof tile adhesive. . PHYSICAL PROPERTIES: Property Test Density ASTM D 1622 Compressive Strength ASTM D 1621 Tensile Strength ASTM D 1623 Water Absorption ASTM D 2127 Moisture Vapor Transmission ASTM E 96 Dimensional Stability ASTM D 2126 Closed Cell Content , ASTM D 2856 Results 1.6 lbs./ft.3 18 PSI Parallel to rise 12 PSI Perpendicular to rise 28 PSI Parallel to rise 0.08 Lbs./Ft2 3.1 Perm / Inch +0.07%Volume Change @ -40' F., 2 weeks +6.0% Volume Change @158°F., 100% Humidity, 2 weeks 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 11-0124.04 Expiration Date: 05/10/12 Approval Date: 04/14/11 . Page 2 of 7 L_.. 1111 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Center for Applied Engineering #94-060 . TAS.101 04/08/94 257818-IPA TAS 101 12/16/96 25-7438-3 SSTD 11-93 10/25/95 25-7438-4 25-7438-7 SSTD 11-93 11/02/95 25-7492 SSTD 11-93 12/12/95 Miles Laboratories NB-589-631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories, Inc. 9637-92 ASTM E 108 04/30/93 Southwest Research Institute 01-6743-011 ASTM E. 108 11/16/94 01-6739-062b[1] ASTM-E 84 01/16/95 Trinity Engineering 7050.02.96-1 TAS 114 03/14/96 Celotex Corp. Testing Services 528454-2-1 TAS 101 10/23/98 528454-9-1 528454-10-1 520109-1 TAS 101 12/28/98 520109-2 520109-3 520109-6 520109-7 520191-1 TAS 101 03/02/99 520109-2-1 LINIITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. Polypro® AH160 shall solely be used with flat, low, & high the profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of Polypro® AH160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. Roof Tile manufactures acquiring acceptance for the use of HANDI-STICK roof the adhesive with their tile assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein. 2 F'= MS NOA No.:11-0124.04 Expiration Date: 05/10/12 M�AM�•DA�' COuN7Y Approval Date: 04/14/11 Page 3 of.7 INSTALLATION: 1. Polypro® AH160 may be used with any roof tile assembly having a current NOA that lists uplift resistance values with the use of Polypro® AH160. 2. Polypro® AH160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of Polypro® AH160 shall provide sufficient attachment resistance, expressed as an uplift based system, to meet or exceed the uplift resistance determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA 3. Polypro® AH160 roof tile adhesive and its components shall be installed in accordance' with Roofing Application Standard RAS 120, and Polyfoam Products, Inc. Polypro® AH160 Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by Polyfoam Products, Inc. Polyfoam Products Inc, shall supply a list of approved applicators to the authority .having jurisdiction. 5. Calibration of the Foampro® dispensing equipment is. required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0- 1.15 (A): 1.0 (B). The dispense timer shall be set to deliver 0.0175 to 0.15 pounds per tile as determined at calibration. No other settings shall be approved. 6. Polypro® AH160 shall be applied with Foarnpro RTF1000 or ProPack® 30 & 100 dispensing. equipment only. 7. PolyprolD AH160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 2 to 3 minutes after Polypro® AH160 has been dispensed. 9. Polypro® AH160 placement and minimum patty weight shall be in accordance with the'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Single Paddy Weight Min. rams Two Paddy Weight per paddy Min. rams Flat, Low, High Profiles # 1 35 N/A High Profile (2 Piece Barrel) # 1 17/side on cap and 34/ an N/A Flat, Low, High Profiles #2 24 N/A Flat, Low, High Profiles #3 8 LABELING: All Polypro® AH160 containers shall comply with the Standard Conditions listed herein. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 11-0124.04 Expiration Date: 05/10/12 MIAMI•DAD; ca® Approval Date: 04/14/11 Page 4 of 7 ADHESIVE PLACEMENT DETAIL 1 SINGLE PATTY Mail through plastic cement Pad Beneath Tile) Underlayment 10 in. In Eave Course ° Fascia Eave course only, Eave Closure Keep adhesive approx, 4 Ia. up from weepholes Nail through plastic cement Paddy (Beneath iile) underloyment = _- 10In. _ 2 In. Eave Course Eave Closure Eave course only: Keep adhesive approx.4 in. up Fascia tramweepholes NOA No.: 11-0124.04 Expiration Date: 05/10/12 MlaMt papt=_ couNrr Approval Date: 04/14/11 Page 5 of 7 Nall through plastic cement Underlayment I in. a Eave Closure ADHESIVE PLACEMENT DETAIL 2 SINGLE PATTY Paddy (Beneath Tile) Nall through plastic cement Underlayment .......... Fascia 11 %Eave Cease Nall through plastic cement Paddy (Beneath Tile) Undarlayment 7 in. in. Eave Closure Eave COUTS& Fascia Paddy (Beneath Tile) .,^ Fascia ", weephele Eave closure - Drip edge NOA No.: 11-0124.04 Expiration Date: 05/10/12 MLAMI-DADECOUNTYM Approval Date: 04/14/11 Page 6 of 7 Nail through plastic cement ° . I Single paddy 3 m• under the x 3 in. Single paddy on 2 in. 4 in. under- %e layment ADHESIVE PLACEMENT DETAIL 3 DOUBLE PATTY Paddy Nall through plastic cement (between tile) Underlayment Paddy (under tllo) ° f ° 0 have course Single paddy 2 in. X 7 In. medium on top of file size paddy eave Fascia course only Nail through plastic cement in.x 3 in. 4 Single paddy on underlayment 2 ° Single paddy on top of tile Eave Course 4 }�in.x 3 in. Single 4 In. f Z in. paddy on under• layment Single paddy on top of the Eave Course raddy the Single paddy between Tile Eave Closure in. x 7 in. medium ze paddy save course only i END OF THIS ACCEPTANCE' MAMMA DE COUNTY Single paddy under the Single paddy between tile 2 in. x 7 in, medium size paddy eave course only Fascla Weephole Eave closure Drip edge NOA No.: 11-0124.04 Expiration Date: 05/10/12 Approval Date: 04/14/11 Page 7 of 7 BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA Polyglass USA Inc. 150 Lyon Drive Fernley, NV 89408 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T. (786) 315-2590 F (786) 315-2599 www.miamidade.sov/buildinQ/ SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform. in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been desi Ding Co / . &C®E8-&NEN � including the High Velocity Hurricane Zone of the Florida Buil ing�g�}oa�agp Gp, 3aa3� 06 yzo DESCRIPTION: Polyglass Polystick Underlay ments (772) 489036 s LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city; state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. - - RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination'and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews and revises NOA # 09-0806.07 and consists of pages 1 through 8. The submitted documentation was reviewed by Alex Tigers.. NOA No.: 11-0601.10 Expiration Date: 09/13/16 M oaoe couN ry Approval Date: 09/15/11 paaP 1 of R ROOFING COMPONENT APPROVAL Catellory: Roofing Sub-Cate$!ory: Underlayment Material: SBS , APP Self -Adhering Modified Bitumen PRODUCTS DESCRIPTION: Test Product Product Dimensions Specification Description Polystick MTS Roll: TAS 103 A homogeneous, rubberized asphalt underlayment 6518" x 3'3 3/8" waterproofing membrane, glass fiber reinforced Manufacturing Location 60 mils thick with polyolefinic film on the upper surface for #2 use as an underlayment for metal roofing, roof tile; slate tiles and shingle underlayment. Polystick IR-Xe Roll: TAS 103 and A fine granular/sand top surface self -adhering, underlayment 65' x 3'33/8" ASTM D 1970 APP polymer modified, fiberglass reinforced, Manufacturing Location Or 65' x 3' bituminous sheet material for use as an #1 & #2 80 mils thick underlayment in sloped roof assemblies. Designed as an ice & rain shield and as a flat roof tile underlayment. Polystick TU Roll: TAS 103 and A heavy granuled surface self adhering, APP underlayment 32' 10" x 3'33/$" ASTM D 1970 polymer modified, fiberglass or polyester Manufacturing Location 100 mils thick reinforced, bituminous sheet material for use as 41 & #2 an underlayment in sloped roof assemblies. Designed as a a roof tile underlayment. Polystick TU Plus Roll: TAS 103 and A non -wicking fabric surfaced, self -adhering, underlayment 65' x 3'33/8" ASTM D 1970 APP polymer modified, fiberglass reinforced (Facer of Membrane 80 mils thick with a high strength polyester fabric, bituminous with surface printing) sheet material for use an an underlayment in Manufacturing Location sloped roof assemblies. Designed as a metal #1 & #2 roofing and roof tile underlayment. Polystick TU P Roll: TAS 103 and A rubberized asphalt waterproofing membrane, underlayment 32' 10" x 3'33/8" ASTM D 1970 glass-fiber/polyester reinforced, with a granular Manufacturing Location 130 mils thick surface designed for use as a tile roof 42 underlayment. Polystick Tile Pro Roll: TAS 103 and' A rubberized asphalt self -adhering, glass - Manufacturing Location 61' x 3'33/8" ASTM D 1970 fiber/polyester reinforced waterproofing #2 60 mils thick membrane. Designed as a metal roofing and roof tile underlayment. NOA No.: 11-0601.10 Expiration Date: 09/13/16 MIAMI•DAD6 COUNTY Approval. Date: 09/15/11 Paee 2 of 8 PRODUCTS DESCRIPTION: Product Dimensions Polystick Dual Pro Roll: Manufacturing Location 61' x 3'3 3/8" #2 60 mils thick MANUFACTURING PLANTS: 1. Hazelton, PA 2. Winter Haven, FL EVIDENCE SUBMITTED: Test Specification Product Description ASTM D 1970 A rubberized asphalt self -adhering, glass- fiber/polyester reinforced waterproofing membrane, specific for use as a high temperature underlayment. Designed as a metal roofing. Test Agency Test Identifier Test Name/Report Date Exterior Research & Design, LLC 11756.04.01-1 TAS 103 04/27/01 11756.08.01-1 ASTM D 1970 08/14/01 02202.08.05 TAS 103 08/29/05 Trinity I ERD P5110.08.07 TAS 103 08/29/07 P10870.09.08-R1 TAS 103 12/04/08 Pi0870.04.09 TAS 103/ASTMD4798 & G155 04/13/09 P33360.06.10 ASTM D1970 07/01/10 P33370.03.11 TAS 103 03/02/11 P36900.09.11 TAS 103/ASTM D4798 & G155 09/01/11 PRI Asphalt Technologies PRIO1111 ASTM D 4977 04/08/02 PUSA-005-02-01 ASTM D 4977 01/31/02 PUSA-018-02-01 ASTM D 2523 07/14/03 PUSA-035-02-01 TAS 103 09/29/06 PUSA-033-02-01 ASTM D 1970 01/12/06 PUSA-055-02-02 TAS 103 12/10/07 PUSA-083-02-01 TAS 103 06/30/08 PUSA-089-02-01 TAS 103/ASTM D4798 & G155 07/06/09 Momentum Technologies, Inc. JX20H7A TAS 103/ASTM D4798 & G155 04/01/08 RX14E8A TAS 103/ASTM D4798 & G155 11/09/09 DX23D8B TAS 103/ASTM D4798 & G155 02/18/10 DX23D8A TAS 103/ASTM D4798 & G155 02/18/10 NOA No.: 11-0601.10 LO CO Expiration Date: 09/13/16 MIAMMIUNTY TJIJJ Approval Date: 09/15/11 Paee 3 of 8 INSTALLATION PROCEDURES: Deck Type 1: Wood, non -insulated Base Sheet:. One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2 & -1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Membrane: Polystick membranes self -adhered. Surfacing: None 1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels, and sweep the deck thoroughly to remove any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied. . All side laps shall be a minimum of 3-'/2" and end laps shall be a minimum of 6." Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. 5. For ridge applications, center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention to lap areas. 7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. S. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be applied over the underlayment. NOA No.: 11-0601.10 Expiration Date: 09h1 116 Approval Date: 09/15/11 ID- A -f 4 GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. Polystick MTS, TU Plus, and Tile Pro may be used in asphaltic shingles, wood shakes and shingles, non- structural metal roofing, roof tile systems and quarry slate roof assemblies. IR-Xe, TU, and TU P may be used in all the previous assemblies listed except metal roofing. Dual Pro may be used in all the previous assemblies listed except roof tile systems. 3. Deck requirements shall be in compliance with applicable building code. 4. Polyglass Polystick membranes shall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities. S. Polyglass Polystick membranes and underlayments shall not be adhered directly over a pre-existing roof membrane as a recover system. 6. Polyglass Polystick membranes shall not be left exposed as a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the preceeding maximum time limitations. Expos re Limitations (days) MTS IR-Xe TU TU Plus TU P Tile Pro Dual Pro Winter Haven, FL. 180 180 180 180 180 180 180 Hazelton, PA. N/A 30 30 180 N/A N/A N/A 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B-72 of the Florida Administrative Code. 8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice of Acceptance. Polystick TU and TU Plus may be used in both adhesive set and mechanically fastened roof tile applications. Polystick IR-Xe, and Tile Pro are limited to mechanically fastened roof tile applications. Polystick MTS is limited to mechanically fastened with battens roof tile applications. Polystick TU P may be used in both adhesive set and mechanically fastened roof tile applications with the exception of mortar set tile applications. 9., The maximum roof slope for use as roof tile underlayment for (direct -to -deck) tile assemblies shall be as follows: (See Table Below) Tile Profile Polystick MTS Polystick ]IR-Xe Polystick TU, TU Plus, TU P, Tile Pro Flat Tile Prohibited without battens 5:12 No limitation Profiled Tile Prohibited without battens Prohibited No limitation The above slope limitations can be exceeded only by using battens and counter battens in accordance with the Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. Battens are required for both loading and installation of tiles at all times. NOA No.: 11-0601.10 Expiration Date: 09/13/16 MiAMI-DADecoutvTY Approval Date: 09/15/11 n.—IZ„r Q GENERAL LIMITATIONS: (CONTEWED) 10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure for all underlayments except Polystick MTS which shall be loaded onto battens. 11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. Polystick MTS, IR-Xe, TU, TU Plus, TU P, Dual Pro and Tile Pro may be used with any approved roof covering Notice of Acceptance listing Polystick MTS, IR-Xe, TU, TU Plus, TU P, Dual Pro and Tile Pro as a component part of an assembly in the Notice of Acceptance. If Polystick MTS, IR-Xe, TU, TU Plus, TU P, Dual Pro and Tile Pro is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. LABELING: 1. All membranes or packaging shall bear the imprint or.identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. MIAMI•DADE COUNTY BUILDING PERMIT REQUIREMENT& Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. NOA No.: 11-0601.10 Expiration Date: 09/13/16 Approval Date: 09/15/11 Pa"A 9 of A POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES: 1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. 2. All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1" metal disk as required in Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being back -nailed. (Please refer to applicable local building codes prior to installation.) 3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact. 4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic, applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations #9 and #10. 6. Battens and/or Counter -battens, as required by the tile manufacturers NOA's, must be used on all projects for pitch/slopes of T712" or greater. It is suggested that on pitch/slopes in excess of 6'/a"/12", precautions should be taken, such as the use of battens to prevent tile sliding during the loading process. 7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours. 8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing . Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic to the area in need of repair, followed by a patch of the Polystick.material of like kind should be set and hand rolled in place over the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. 10. All self -adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling. 11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request. It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes and PolyProtector UDL can be furnished upon request by our Technical Services Department by calling 1 (800) 894-4563. NOA No.: 11-0601.10 Expiration Date: 09/13/16. MIAMI•DAD, COUNTY Approval Date: 09/15/11 Page T of 8 13. Questions in regards to the application of Polyglass products should be directed to our Technical Services Department at 1 (800) 894-4563. 14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by the National Roofing Contractors Association (NRCA). PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. END OF THIS ACCEPTANCE NOA No.: 11-0601.10 MIAMI•bADE COUNTY Expiration Date: 09/13/16 Approval Date: 09/15/11 Page 8 of R