APPLICATION FOR ROOF PERMIT
SEE REVERSE SIDE FOR INSTRUCTIONS
Location/Site Address:�Cy' C% %,it' 4 -S
Parcel ID Number: L1b / - Z/-/ 3 ✓ �� y
Office Use
Only
Description of Project or Work Activity: �-o
Total Roof Area (square feet): 3 a0_0 5. Roof Pitch:
6. Type of Roof. [ ] Fiberglass Shingle [ ] Concrete Roof Tile [ ] Wood Shake / Shingle
[ ] Tar & Gravel [ ] Modified Bitumen [b<J Other /7AL-
[ ] Product Approval required for all types of Roofing Material (2 Sets)
] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product
Approval attached
** Roof. Mitigation per F.S. 553.844 will be required.
7. Owner Information 8. Contractor Information
Name: %FoQxv? i �AOS1'—FL Reg/Cert #: C'CC
Address: 601 a- C: T✓?.P/ ' ,firm' County Cert #:
City: State: X-4- Business Name: _STrUf 60c,,P%AM 6 Fis ,72�
Zip: 3 y q 8'-- Phone: 9/6 - 93 77 Cell Phone: �a' 3.36- 3$ $D
9. Value of Construction: $ LZ 10�,V,00
"Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval.
CONTRACTORIOWNER'S AFFIDAVIT: I certi!at al he inform on ontained in this application is ect and that all work will be
d in pl and with a] pplic ble laws regulating construction an zoning.
PRINT QUALIFIERS/OWNERS NAME SIGNATtIRP OF QUALIFIER/OWNER
STATE OF FLORIDA, COUNTY OF fn A 4;Ti IJ
ACKNOWLEDGED BEFORE ME THIS DAY OF 20 (2L, BY _15�f'_ i�r oo -ev-Gt
IS
IS PERSONALLY {NOWN V TO ME OR HAS PRODUCED AS IDENTIFICATION
0,44MO a F Y 4AJ7A/U7°,cl t> VULT
Notary Public State of Florida
NATURE OF NOTARY TYPE OR PRINT NAME OF NOTARY (seal`f�
. Carmela Frantantoni
COMMISSION NUMBER �� a2flo2 �%�� �MyCommission EE 202791
Expires05129/2016
NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RN YOUR PAYING TWICE
FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT HOUR LENDER OR
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
Revised 4/26/2010
4�
�La
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34982
772-462-2165 or 772-462-2172
Fax: 772-462-6443
ROOF INSPECTION AFFIDAVIT
Re: Permit # 'S'
I, S7.,af/4 , licensed as a( Contractor /Engineer/Architect
(Please print name & circle license type) *FS468 Building Inspector
*General, Building, Residential or Roofing Contractor or any individual certified under 468 F.S. to make such an inspection.
On or about I did personally inspect the roof deck nailing
(Date)`
work at: �4 / �% t't/2P /1�
(Job site address)
Based upon examination I have determined the installation was done according to the Hurricane
Mitiga ' n Re,trofft Manual (Based on 553.844 F.S.)
and Seal
STATE OF FLORIDA
COUNTY OF il'1Al2:�n
ACC-- / z 2"�d- O
License #
Sworn to and subscribed before me this 10 day of , eCember 20j_ -
by —' L Ga26A& Yn Who is pe3�_ orally known to me or who has produced
as identification.
Notary Public, State of Florida
Signature of Notary:
Commission Number: 5-dR— 14,
En 01/19/2011
!00 Notary Public State of Florida
Carmela Frantantoni
(Seal) My Commission EE 202791
�lor10 Expires 05/2912016
JOSEPH E. SMITH, CLERK OF THE CIRCUIT COURT - SAINT LUCIE COUNTY
FILE # 3763872 OR BOOK 34, PAGE 679, Recorded 10/30/2012 at 04, PM
NOTICE OF COMMENCEMENT
Permit No. Tax Folio No.3`io9-`11g-0003 -000-o
State of Florida County of St. Lucie
The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes,
the following Information Is provided in this Notice of Commencement.
Legal Description of Pro�erty: (and street address if available):
q36 Yr3 /6Sf 9FWsdI/.l �'rofs33t�fT'ofyW��yofiL� �yOf 5F ��/-LASS
6o/OL G;TRAI-5 PVX Yvr )9.TE c.E
General description of Improvement: %1GvJ VA4 t 1jmf!
)
Owner inf= or lesss see Information If the Leee contracted for the Improvement:
Name a sate
Address 4017s F'd
Interest in property: r-Af
3i
Name and address of fee simple titleholder (if different from Owner listed above):
n
v
Contractors Name:
Contractor Address., O�E o O>t 966/ L6f6rE Ft. 3Y20Phone Number: ZP-336 38. n
Surety (if applicable, a copy q(t}ig payment bond is attached): Amount of bond: $
9�1
Name and address: Phone number:
Lender Name: P i1 Phone Number:
1
Lender's address:
L
v
Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section
713.13(1)(a)7., Florida Statutes:
Name: Phone Number:
In addition to himself or herself, Owner designates of
Uenors Notice as provided In Section 713.13(1)(b), Florida Statutes.
Phone number of person or entity designated by owner:
receive a copy of the
Expiration date of notice of commencement: (the expiration date may not be before the completion of construction and final payment to the
contractor, but will be 1 year from the date of recording unless a different date is specified)
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED
IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR
RECORDING YOUR NOTICE OF COMMENCEMENT.
Under penalty of perjury, I declare that I have read the foregoing notice of commencement and that the facts stated therein are true to the best of
my kno lyl edge and�belief
Ale (t*`/erl
x
(Signature of Owner or Lessee, or Owners or Lessee's Authorized Officer/ ctor/Partner/Manager
n. ,l11Z1r-
(Signatory/s Title/Office) (� /}. ��
The fojygo_Ipg InsttpnjePt ysacs� gged before me this ` day d b. to , 2�c7�
gymK�CJ�JG��� 1M3 l--1 s O as Dl lS?�e � for
Pam f Person Type of authority (e.g.officer trustee) Party on behalf of whom instrument was executied
nupogkm Personally known_or produced identificatio4i
(Signature of Notary Public -Sta tf"P11111110.IIMadpbft
(Print, Type, or Stamp Commies a NIIjr3}AtbEajYp SIP B, lBfB Type of Identification produced I 'mac'
CoraaiaaalM / @ tlNtir
STATE OF FLOR4DA
CT. LUCIE COUNTY
THIS I
THE
ORIV
J
By:
pfte
PAUL WELCH INC.
Mechanical Electrical Civil Engineering
1984 S.W. Biltmore St. Suite# 114
;:. Port Saint Lucie, FL 34984
Phone 772 785 - 9888
Fax (772) 785-9933
November 5, 2012
Re: Holgerson Metal Roof
6012 Citrus Ave.
Fort Pierce, FL 34982
SCOPE OF WORK:
Remove existing roofing material and install new Standing Seam Metal Roof (Metal Sales
Manufacturing Corp. FL # 11560.4) over underlayment at above referenced residence address.
DESIGN CRITERIA:
FBC 2010
ASCE7-10
PROJECT DATA:
BUILDING HIEGHT = 8' -0"
MEAN ROOF HIEGHT = < 30'
ROOF ANGLE = 4:12
SHAPE = GABLE
ADJUSTMENT FACTOR = 1.00
RViPROTANCE FACTOR =1.00
WIND VELOCITY =160 MPH
EXPOSURE = B
ENCLOSURE CLASS = ENCLOSED BUILDING
INTERNAL PRESSURE COEFFICIENT = -0.18
APPLIED UPLIFT DESIGN PRESSURES ON ROOF (osn:
ZONE 1 (Field) = - 25.3
ZONE 2 (Perimeter! Ridge) _ - 42.7
ZONE 3 (Comers) _ - 65.1
1 of 3
ROOF DATA:
Manufacturer:
Metal Sales Manufacturing Corporation
Product name:
Image H
FL#:
11560.4
Panel Description:
Standing Seam 16" wide coverage with 1" high ribs
Design Pressure:
DP = -84.25
Underlayment:
Carlisle Coatings & Waterproofing CCW Roof Underlayment
CCW WIP 250
Deck:
15/32" Plywood
METAL ROOFING ATTACHMENT REQUIREMENTS:
Panels shall be attached with #10 pancake head screws along the panel seam. Fasteners shall be
of sufficient length to penetrate through the roof sheathing/decking a minimum V4". Fasteners
shall be spaced at 24" O.C. maximum along the entire length of each panel.
All zones require same attachment 84.25 nsf > 65.1nsf Therefore O.K.
UNDERLAYMENT INSTALLATION:
Underlayment shall be Carlisle Coatings & Waterproofing CCW Roof Underlayment CCW WIP
250 (FL#-6785.1)
Shall be installed in compliance with the requirements for ASTM D 1970 underlayment in FBC
Sections 1507 for the type of prepared roof covering to be installed. Cut WIP roofing
underlayment into 10 to 15 ft lengths. Remove 2 to 3 ft of release film and align the edge of the
membrane, sticky -side down, so it overhangs the drip edge by 3/8-inch. Continue to remove
release film and press as you move across the roof. Use a hand roller and/or hand pressure to
press into place. Horizontal seams should be minimum 3.5-inches, configured to shed water.
Vertical seams should be 6-inches and staggered not less than 2-ft from vertical seams in the
course below.
DECK INSTALLATION:
Re -nail all plywood sheathing (15/32" thick minimum) with 8D ring -shank X 2.5" long nails at
4" O.C. perimeter and 6" O.C. field for all zones.
All work to be in compliance with product approval (FL# 11560.4), (FL# 6785.1),
manufacturer's specifications, and the Florida Building Code 2010.
Submitted by:
PAUL WELCH INC.
Paul Welch, P.E..
Reg. No 29945
PW:pj ,
2 of 3
O
v�51Cs t-�ATia�J
=3°
CB o t 2 c rT,e�dS .4�. roar jw�eAw
PAUL WELCH I
MECH-ELECT-CIVIL ENG
1884 BILTMORE ST. #114
PORT ST. LUCIE, FL 34W
PAUL WELCH, P.E. FLA REG NO 29M 0' S' 2912
v)
I
IG
3 Qf 3
!,p
t{
?f EVALUATION REPORT OF
METAL SALES MANUFACTURING CORPORATION
`26 GA. IMAGE 11 PANEL'
�j
FLORIDA PRODUCT APPROVAL
FL 115601.4-R1
j ROOFING
METAL ROOFING
Prepared For:
Metal Sales Manufacturing Corporation
. 545 South P Street, Suite 200' .
Louisville, KY 40202
Telephone: (502) 855-4300
Fax: (502) 8554290
Prepared By:.
Bala Sockalingam, Ph.D., P:E.
G Florida Professional Engineer #62240
1216 N Lansing Ave.,' Suite C
r Tulsa, OK 74106
Telephone: (918) 492-5992
FAX: '(866) 366-1543
a
'i
ki
{
This, report consists of.
Evaluation Report (3 Pages including cover)
Installation Details(! Page)
1
No 622
*•so
Report No. C1800-19
a Date: 12.9.11.
% 0 STATE 'OF Qj :
'RR O.G,��♦,
Manufacturer:
Product Name:
Panel Description:
Materials:
Deck Description:
Deck Attachment:
New Underlayment:
FL 11560.4-R1
C1800-19
12.9.11
Page 2 of 3
Metal Sales Manufacturing Corporation
Image II
Max. 16" wide coverage with 1" high ribs
Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or
Galvalume coated steel (ASTM A792) or painted steel (ASTM A755).
Min. 15/32" thick plywood for new and existing constructions.
Designed and installed as per FBC 2010.
8d x 2.5" long ring shank nails or #8 x 2" long wood screws @ 6" o.c.
in the plywood field and @ 4" o.c. at edges
Minimum underlayment as per FBC 2010 Section 1507.4.5
Existing Underlayment: One layer of asphalt shingles over one layer of #30 felt. For reroofing
(Optional) construction only.
Slope: 2:12 or greater in accordance with FBC 2010 Section 1507.4.2 and
1504.6
Design Uplift Pressure: 84.25 psf @ fastener spacing of 24" o.c.
(Factor of Safety = 2)
Fastener Pattern: #10 pancake head screws along panel seam. Fastener shall be of
sufficient length to penetrate through the deck a minimum of 1/".
Test Standards: Roof assembly tested in accordance with UL580-94 (Rev 98) `Uplift
Resistance of Roof Assemblies' and TAS 125-03 `Standard
Requirements for Metal Roofing Systems'.
Code Compliance: The product described herein has demonstrated compliance with FBC
2010 Section 1507.4
Product Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2010 Section 1609 or ASCE 7-10 using allowable stress
design. The maximum fastener spacing listed herein shall not be
exceeded. This evaluation report is not applicable in High Velocity
Hurricane Zone. Fire classification is not within scope of this
Evaluation Report. Refer to FBC 2010 Section 1505 and current
approved roofmg materials directory or ASTM E108/UL790 report
from an accredited laboratory for fire ratings of this product.
FL 11560.4-R1
C1800-19
12.9.11
Page 3 of 3
Supporting Documents: TAS 125-03 & LL580 Test Reports
Hurricane Test Laboratory, LLC
HTL Report M 0103-0714-09, Reporting Date 9/1/09
NEW UNDERLAYMENT
SEE DETAIL 1 EXISTING SHINGLES MAX. 16" SPACING PANEL APERN
ROOF PANELALLLOWABLE
I N (OPTIONAL) n n l PRESSURE TABLE.
IV, I�_�
EXISTING UNDERLAYMENT 8d x 2.5" LONG RING SHANK NAIL
(OPTIONAL) OR #8 x 2" LONG WOOD SCREWS
MIN. 2X_ WOOD RAFTER/JOIST/ SPACED O 6" O.C. IN THE FIELD
TRUSS AT MAX. 24" O.C. & @ 4" O.C. AT PLYWOOD EDGES
NEW UNDER
EXISTING SHINGL
(OPTIONAL)
EXISTING UNDER
(OPTIONAL)
DETAIL 1
TYPICAL PANEL INSTALLATION X-SECTION
SCREWS
DOD
15/32" THICK (MIN.)
PLYWOOD
15/32" THICK (MIN.)
ALLOWABLE UPLIFT PRESSURE
FASTENER
PRESSURE
SPACING
(PSF)
(IN)
24
84.25
GENERAL NOTES:
1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE
FLORIDA BUILDING CODE (FBC).
2. ROOF PANELS ARE SHALL BE MIN. 26 GA. MAX. EFFECTIVE COVERING WIDTH OF
PANEL = 16".
3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING Sc STRUCTURE AS
SPECIFIED ON THIS DRAWING.
4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS
PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS
ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING.
5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA
BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM
REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL.
6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS
REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS.
a
0 0
U N
z �N
Z
7 NoD
o
D Ln
Cwin
�J 00
N
w
Q cow
ch N J
F Ln
�w N
Li
a:
J
w p u m
OL a m
w Q
z aoq
�o
gm
a
0
c?g
Md
Y�
q
OF
I! 1
\l TRINITY ERD.
EVALUATION REPORT
Carlisle Coatings & Waterproofing
900 Hensley Lane
Wylie, TX 75098
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT #,13
-OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
Evaluation Report C39180.12.11-R1
FL6785-R4
Date of Issuance: 12/09/2011
Revision 1E :04/22/2012
SCOPE:
This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing .
the use of construction materials in the State of Florida. The documentation submitted has been..
reviewed .by RobertNieminen, P.E. for use of. the product under. the Florida Building Code and
Florida Building Code, Residential Volume. The products described herein have been designed to
comply with the 2010 Florida Building Code sections. noted herein.
DESCRIPTION: CCW Roof Underlayments
LABELING: Each unit shall bear labeling in accordance. with the requirements the Accredited Quality
Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)
changes, the referenced Quality Assurance documentation changes, or provisions of the Code that
relate to the product change. Acceptance of this Evaluation Report by the named client constitutes
agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality
Assurance documentation changes: TrinitylERD requires. a complete review 'of this Evaluation
Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may
be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it
shall be done in its entirety..
INSPECTION: Upon, request, a copy of this entire Evaluation Report shall be provided to -the user -by
the manufacturer or its distributors and shall be available for inspection at the -job site at the
request of the Building .Official.
This Evaluation Report consists of pages 1 through 4.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearingwas authorized' '
by Robert Nieminen, P.E. on 04/22/2012
This does not serve as an electronically signed
document Signed, sealed hardcopies have been
transmitted to the. Product Approval Administrator: and
to the named client .
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a ,financial interest in any company manufacturing or:
distributing products it evaluates.
2. TrinitylERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which
the evaluation_ reports are being issued:
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
` TRIiIIIY,� ERD_
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: CCW Roof Underlayments, as produced by Carlisle.Coatings & Waterproofing,
have demonstrated compliance with the following sections of the Florida Building Code through testing
in accordance with the following Standards. Compliance is subject to the Installation Requirements and
Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.4, 1507.2.9.2, Physical Properties ASTM D1970 2001
1507.5.3
3. REFERENCES:
Entity
Examination
Reference
Date
MTI (TST2508)
Physical Properties
PX02MOA
01/17/2011
MTI (TST2508)
Physical Properties
PXI6MOA
01/18/2011
MTI (TST2508)
Physical Properties
PXI3MOB
01/18/2011
M-D (CER1592)
HVHZ Compliance
09-0630:13
08/12/2009
ICC-ES (EVL2396)
2006 IBC Compliance
ESR-1556
08/01/2007
UL, LLC. (QUA9625)
Quality Control
Inspection Report, R18678
02/20/2012
4. PRODUCT DESCRIPTION:
4.1 CCW WIP 100 is a self -adhering, fiberglass reinforced, granule surfaced, rubberized asphalt
roof underlayment.
4.2 CCW WIP 250 is a self -adhering, fiberglass reinforced, film surfaced, rubberized asphalt roof
underlayment.
S. LIMITATIONS:
5.1 This Evaluation Report is not for use in the HVHZ.
5.2 Fire Classification is not part of this report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
5.3 CCW Roof Underlayments may be used with any prepared roof cover where the product is
specifically referenced within FBC approval documents. If not listed, a request.may be made to
the AHJ for approval based on this evaluation combined with supporting data for the prepared
roof covering.
5.4 Allowable roof covers applied atop the underlayments are follows:
0
Table 1: Roof Cover Options
Underlayment
Asphalt
Nail -On Tile
Foam -On
etal
Wood
Shakes &
Slate &
Synthetic
Shingles
Tile
Shingles
Slate/Shake
CCW WIP. 100
Yes
No
No
No I
No
No
C&•CWrWIP 25�
�y �Y,esr�errNorrraM
�wr�No��
Yes
No
No
Exterior Research and Design, LLC. Evaluation Report C39180.12.11-R1
Certificate of Authorization #9503 FL6785-R4
Revision 1: 04/19/2012
. Page 2 of 4
NTWNITY I ERD;
5.5 Allowable substrates are noted below:
5.5.1 Direct -Bond to Deck:
Self -adhering -membranes applied to:
➢ New untreated plywood;
➢ Primed new untreated plywood;
➢ Existing plywood;
➢ Primed existing plywood;
Note: While not required,_ CCW-702 or CAV-GRIP primer may be used when deemed_
appropriate or when temperatures are below 40°F.
5.5.2. Bond to Mechanically Attached Base Layer:
Self -adhering membranes applied to:
➢ ASTM D226, Type I or II felt;
For installations under mechanically attached prepared roof coverings,. base layer shall be
attached per minimum codified requirements.
5.6 Exposure Limitations:
5.6.1 CCW WIP 100 and CCW WIP 250 shall' not be left exposed for longer than 30-days after
installation. -
6. INSTALLATION:
6.1 CCW Roof Underlayments shall be installed in accordance with Carlisle Coatings &
Waterproofing -published installation requirements subject to the Limitations set forth in
Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail- heads. Sweep the
substrate thoroughly. to remove any dust and debris prior to application. Prime the substrate.
(if applicable). with CCW-702 or CAV-GRIP Primer.
6.3 CCW WIP 100 and CCW WIP 250:
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC
Sections 1507 for the type of prepared roof covering to be installed.
6.3.2 While not required, CCW-702 or CAV-GRIP primer may be. used when deemed appropriate.
Priming is required when temperatures are below 40°F.
6.3.3 Cut WIP .roofing underlayment into 10 to 15 ft lengths. Remove 2 to 3 ft of release film and
align the edge of the membrane, sticky -side down, so it overhangs the drip edge by 3/8-inch.
Continue to remove release film and press as you move across the roof. Use a'hand roller
and/or hand pressure to press into place.
6.3.4 Horizontal seams should be minimum 3.5-inches, configured to shed water. Vertical seams
should be 6-inches and staggered not less than 2-ft from vertical seams in the. course below.
6.3.5 Consult Carlisle Coatings & Waterproofing for steep slope &.back nailing requirements.
6.3.6 For Valleys and Ridges: Cut WIP 100 roofing underlayment into, manageable lengths. Align
over the center of the. valley, hip or ridge. Remove release film.. Press the middle of the
membrane first before working toward the edges. For open, valleys, 'cover roofing
underlayment with metal valley liners.
Exterior Research and Design, LLC. Evaluation Report C39180.12.,11-Ri
Certificate of Authorization #9503 FL6785-114
Revision 1: 04/19/2012
Page 3:of 4
�r
TINITY I ERD
` 7. LABELING:
Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the
Accredited Quality Assurance Agency noted herein.
S. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or :Authority Having Jurisdiction in order to properly evaluate the .
installation of this product.
9. MANUFACTURING PLANTS:
Contact -the manufacturer or the named QA entity for plants covered under Rule 9N-3 QA
-requirements.
10. QUALITY ASSURANCE ENTITY:
UL, LLC— QUA9625; (847) 664-3281
- END OF EVALUATION REPORT -
Exterior Research and Design, LLC.
Certificate of Authorization #9503
Evaluation Report.C39180.12.11-R1
FL6785-R4
Revision 1: 04/19/2012
Page 4 of 4
Planning and Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34982
Phone:772-462-2165 Fax:772-462-6443
REROOF WINDSTORM LOSS MITIGATION COMPLIANCE AFFIDAVIT
To be completed if the value of the single-family residence is over $300,000 and built prior to March 1, 2002. Must be completed
by a licensed General, Building or Residential Contractor or State of Florida registered Architect or Engineer.
Description of Work: /�% J--
Job Site Address: &/3'0 A� G �-�& � /:I -
License Holder's Name: s%fli.4 /VT�11i¢ License No: CCG /3 olZ 69-Vf�>
Company Name: SjA&i� Phone No: %77- 336-3 $a
I, do hereby affir(n that the residential structure is valued at $300,000 or more and has
the following existing roof -to -wall connection which co plies to the Windstorm Loss Mitigation requirements as per Florida
Statute 553.844.
Check one of the following:
o The existing roof- -wall connectio meet the c rent code requirements for roof -to -wall connections and/or roof -to -
foundation load path requireme s.
o The roof -to -wall connectiony4vill be enhanced up to 15% of the cost of the roof replacement using metal connections,
clips, straps and fasteners to achieve an uplift capacity as specified in Table 201.3 of the Hurricane Mitigation Retrofits
for Existing Site -built Single Residential Structure Manual.
o The evaluation and installation of the roof -to -wall connections at gable ends or corners cannot be completed for 15% of
the cost of the roof replacement.