Loading...
HomeMy WebLinkAboutSUBMITTED PAPERS� ✓ t J �r oe TE: FEES DUE: RECEIPT #: n Permit #: I � 1 ;f Planning & Development Services Department Building & Code Regulation Division �, a n 2300 Virginia Avenue CIq�A'c Ft Pierce, FL 34982-5652 Tel. 772462-1553 �t `UC/� APPLICATION FOR ROOF PERMIT C®UnM, SEE REVERSE SIDE FOR RIIIN,STRU NS 1. Location/Site Address://3 �fl FrL� �T7 - n2,� El 2. Parcel ID Number: 13/a Office Use Section Township Range Ma Page in Land Use Initial Only � S. -'75f-'4 11SP a t J31 Vnq ACL UWA 3. Description of Project or Work Activity: _l �r t��T /2 -� � 4. Total Roof Area (square feet): K 5. Roof Pitch: 0�t-z, 6. Type of Roof: [Fiberglass Shingle [ ] Concrete Roof Tile [ ] Wood Shake / Shingle [ ] Tar & Gravel [ ] Modified Bitumen [ ] Other {Product Approval required for all types of Roofing Material (2 Sets) [ All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product Approval attached **Roof Mitigation per F.S. 553.844 will be required 7. Owner Information pp 8. Name: Address: f-e City: 1!t. P State: Zip: q-'-)( Phone: 7%a ' 11(6 ' �9,9' / Contractor Information FL Reg/Cert #: (&1 CL5_?Q 0'1 County Cert #: ePO-S® Business Name: � �'1 i L �e �(�� Cell Phone: "A( f 9. Value of Construction: $ %V' 0 70, **Note Dry -in and Final Inspection Required. Additional inspection maybe required per Product Approval. CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in compliance with all applicable laws regulating cons zoning. PRINT QUALIFIERS/OWNERS NAME y� S URE OF QUALIFIER/OWNER STATE OF FLORIDA, COUNTY OF ACKNOWLEDGED BEFORE ME THIS � DAY OF 20 (' Z, BY 41GNA IS PERS ZN LY WN TO ME OR HAS PRODUCED AS IDENTIFICATION �a-iycy [� �i9rvl-cL� �p`��",pYP�.� Nancy L. Hamilton T E ARY�j� TYPE OR PRINT NAME OF NOTARY (seal#'2��'� - COMMISSION # EE035845 COMMISSION NUMBERIXPIRES: OCT. 19,2014 WWW.AARONNOTARY.COm NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Revised 4/26/2010 r Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 772-462-2165 or 772-462-2172 Fax: 772-462-6443 ROOF INSPECTION AFFIDAVIT Re: Permit # 12/1 ' 0 Q 9 8 I, &C 5ae41dZ4J_ , licensed as a(n)Contractor*/Engineer/Architect (Please print name & circle license type) *FS468 Building Inspector *General, Building, Residential or Roofing Contractor or any individual certified under 468 F.S. to make such an inspection. On or about 11( /L�2 , I did personally inspect the roof deck nailing (Date) work at: A /�� %ir9'� ���i - t-L .3� `S % (1ob'site address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S.) Signature and Seal STATE OF FLORIDL / COUNTY OF L&Ie- 195?6 C)-/ License # SwcR to and subscribed before me this U day of /yy V 20 1 by iZ° 4"J/a41Q y Who is personally known to me or who has produced as identification.. Notary Public, Sta o r"a Signature of Nota y: Commission Number. (Seal) En 01/19/2011 ylllp>, Y L Hamilton COMOSS ON#EE035845 EXPIRES: OCT. 19 2014 AARONNOTAF?y,m Permit No. State of Florida County of St. Lucie NOTICE OF COMMENCEMENT Tax Folio No. 131 R 801-o 5!'-0&1-9 The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. et General description of improvement: eAle- 09* Owner inf ation or Lesse information i the Lessee contracted for the improvement: Name lJ . Address 5113 Interest in property: Name and address of fee simple titleholder (if different from Owner listed above): Contractor's Name: Contractor Address: Surety (if applicable, a copy of the payment bond is attached): Amount of bond: $ Name and address: Lender Name: _ Lender's address: Number: Phone Number: number: :1V6a-<g93) Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1) (a)7., Florida Statutes: Name: Phone Number: Address: In addition to himself or herself, Owner designates Lienor's Notice as provided in Section 713.13(1) (b), Florida Statutes. Phone number of person or entity designated by owner: to receive a copy of th, i Expiration date of notice of commencement: (the expiration date may not be before the completion of construction and final payment to the contractor, but will be 1 year from the date of recording unless a different date is specified) l 13 (1 WARNING TO OWNER:_ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713; PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE' OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. ;tio-110C— rr. 6�rn .L. m f.. A _., rr, m z' ;> > c2 Win; "yin 70 co �, 0 J 'P m X --a 0 C1 x1 e� Under penalty of perjury, I declare that I hake real the foregoing notice of commencement and that the facts stated therein are true to the best of my knowledge and belief.. r (Signature of ffWneVor Lessee, or Owner's or Lessee's Authorized Officer/Director/Partner/Manager (Signatory's Title/Office) The foregoing instrument was acknowledged before me this day of NOV , 20_L�— By kolt7w V • 1.Gt9W,w—.as QdXtj for &4p ame o Person Type of authority (e.g. officer, trustee) Party on behalf of om instrument was executed QL(el ZV g� � �o"""'�% rsonally known or produced Identification �A14?:YP& - Nancy L, Hamilt8tr ( gnature o®r'stamp tary Public - State of Florida) 'i�' � COMA7ISSIONHE035845 (Print, Type Commissioned Name of Notary,Puk i9 Q� EXPIRES: OCT 1.1 2dly e of Identification produced wwAARONNOTARY.com Florida Building Code Online Page 1 of 2 .iG'";:ic De:Y�rs"1:.ili:f aCIS Home Log In I User Registration � Hot Topics .Submit Surcharge Stats & Facts s; S Busines.'�-� (���� Product Approval Professi � 1 lal ix! USER: Public User eau t; lrll Product Aooroval Menu > Product or Auplication Search > Application List > Application Detail R11-1-12�51 M FL # Application Type FL10674-R6 Revision `air a Code Version 2010 Application Status Approved Comments Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo, OH 43659 (740)404-7829 greg.keeler@owenscorning.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo, OH 43659 (419) 376-8360 mel.sancrant@owenscornig.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer n Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who Robert J.M. Nieminen developed the Evaluation Report Florida License PE-59166 Quality Assurance Entity Underwriters Laboratories Inc. Quality Assurance Contract Expiration Date 09/26/2014 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL10674 R6 COI Trinity ERD CI - Nierninen.Ddf Referenced Standard and Year (of Standard) Standard Year ASTM D3161, Class F 2006 ASTM D3462 2007 ASTM D7158, Class H 2O07 Equivalence of Product Standards Certified By hq : //www. flori dabui lding. org/pr/pr_app_dtl. aspx?p aram=wGEVXQwtD gtBNbEY5 V %2... 6/ 15 /2012 t Florida Building Code Online Page 2 of 2 Sections from the Code Product Approval Method Method 1 Option D Date Submitted 02/16/2012 Date Validated 02/21/2012 Date Pending FBC Approval 02/24/2012 Date Approved 04/03/2012 Summary of Products FL # IModel, Number or Name Description 10674.1 Owens Corning Asphalt Roofing 3-tab, laminated, starter, and hip & ridge Shingles and Starters Limits of Use Installation Instructions Approved for use in HVHZ: No FL10674 R6 II er020612FINAL OC FL10674- R6 Asphalt Shingles. odf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert J. M. Nieminen PE - 59166 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to ER, Section 5. Evaluation Reports FL10674 R6 AE er0206.12FINAL OC FL10674- R6_Asphalt Shingles..pdF Created by Independent Third Party: Yes Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, e-mail addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions regarding DBPR's ADA web accessibility, please contact our Web Master at webmaster@dbpr.state.Fl.us. Product Approval Accepts: nxxcq ar vwivg» http://www. floridabuilding.org/pr/pr_app_dtl. aspx?param=wGEVXQwtDgtBNbEY5 VD/o2... 6/15/2012 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 1 B ' ERD OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 EVALUATION REPORT Owens Corning Evaluation Report 037940.02.12 One Owens Corning Parkway FL10674-R6 Toledo, OH 43659 Date of Issuance: 02/06/2012 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2010 FBC and 2010 FBC Residential Volume sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 02/06/2012 This does not serve as an electronically signed document. Signed, sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. TrinitylERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. i I PTRINITYIERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2007 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161, Class F 2006 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158, Class H 2O07 3. REFERENCES: Entity Examination Reference Date UL (CER1739) Physicals & Wind Resistance File R2453, Vol. 3 02/15/2007 UL (TST1740) Physical Properties 06CA20263 04/18/2006 Miami -Dade (CER1592) FBC HVHZ Compliance 07-1116.12 02/14/2008 Miami -Dade (CER1592) FBC HVHZ Compliance 09-0915.12 12/16/2009 Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.09 10/27/2010 Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.10 10/27/2010 Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.08 10/27/2010 Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.07 10/27/2010 Miami -Dade (CER1592) FBC HVHZ Compliance 11-0411.03 06/16/2011 Miami -Dade (CER1592) FBC HVHZ Compliance 11-0919.05 10/13/2011 UL (QUA1743) Quality Control Service Confirmation Exp. 09/26/2014 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic® and Supreme° are fiberglass reinforced, 3-tab asphalt roof shingles. 4.1.2 Berkshire® are fiberglass reinforced, 4-tab asphalt roof shingles. 4.1.3 Duration®, Duration® Premium, Oakridge5 and WeatherGuard° HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Berkshire° Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant and WeatherGuard° HP Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.3 Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVHZ. 5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.3 Wind Classification: 5.3.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for us in all wind zones up to V,sd = 150 mph (V,it = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. Exterior Research and Design, LLC. Evaluation Report 037940.02.12 Certificate of Authorization #9503 FL10674-R6 Date of Issuance: 02/06/2612 Page 2 of 6 5.3.2 All Owens Corning hip & ridge shingles and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for us in all wind zones up to Vasd = 150 mph (Vuit = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.3.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.3.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.4 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C. Rule 9N-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 9N-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following exceptions: ➢ Berkshire° shingles require minimum five (5) nails per shingle. ➢ WeatherGuardO HP shingles require minimum six (6) nails per shingle. ➢ Starter Strip Plus requires minimum five (5) nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the shingle manufacturer for details. 6.2.5 Minimum Nailing - Classic® & Supreme: Normal Mansard or Area para Wind Areas High Wind desvanes y Area pare viontos normaies Areas viontoe fuertes ��"=t, ..,,-tAl-., y11•� r z''3 l6 r2" �"� B'Exposure Expoaioi6n Exterior Research and Design, LLC. Certificate of Authorization #9503 Normat Mansard or Area pars Wind Areas High Wind desvanas y Area pars vientos normafas Areas viantos fuartes r'92t. -• � Aj\ 921 t" �• 2 Z: lB�.-- � 2"'^^,+"� 5 518' Exposure Exposioidn Evaluation Report 037940.02.12 FL10674-R6 Date of Issuance: 02/06/2012 Page 3 of 6 6.2.6 Minimum Nailing - Berkshire®: Sealant strip —► • °l--f • W• f—I i81h" I 9V21 9 , I yiI BVrt TRINITY I ERD Sealant strip La tlra do selfador •t----r • - --► • • -—i • t—i • L8W, 8"h" 8W. t 0 2„ Aspha it roofing oement Cemento do Who de astalto 6.2.7 Minimum Nailing - Duration® & Duration® Premium: 4 Nail Pattern Esquema de 4 clavos SursNalf°fastening area width Area de dawsSureNago t" 1° r�• tr —� 6W Exposure Nails 5°Exposure W pulg. de exposiddn Claws 5a5 pu1g. de exposkidn 6.2.8 Minimum Nailing - Oakridge@: 4 Nail Pattern Esquema con 4 clavos 1° 1. 12- 12- 5518" Exposure Nails 5 610" Exposure &posiddndo66/Spufg. Clavos Exposiconde65/Bpaig. m 6 Nail am a tetween suruuape Pattern area anNtup olcuf out.. Esquema — rwh- Iopea+urdsc da 6 clavos aemiasfipda eMre el •. • • jtaeraasU?aNO09u parts sda �! rasa. Sunfiaae \ SuMaIP fatterJng Jastenng areawWth areara A breade T' preaW cures Sunria7a 12" tr Suee'aIP LE 5W Exposure Nails 544' Exposure 51h ping. do exposkidn clavos 5e% pulg. do exposicidre 6 Nail Pattern Esquerna con 6 clavos r r I� Q. —� i<- IT 5'616" Exposure Nails 6 6/8" Exposure Expostcidn de 55/8 pulg. Exposicldn de 56/8 paig. Exterior Research and Design, LLC. Evaluation Report 037940.02.12 Certificate of Authorization #9503 FL10674-116 Date of Issuance: 02/06/2012 Page 4 of 6 6.2.9 Minimum Nailing - WeatherGuard® HP: r Is Inglei dView a;.?: �:•: 6imrrr7�� Nil lit. 6.3 Hip & Ridge Shingles: 6.3.1 Installation of Berkshire° Hip and Ridge Shingles, High Ridge, Hip & Ridge with Sealant and WeatherGuard° HP Hip and Ridge Shingles shall comply with the manufacturer's current published instructions, using four (4) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand -sealing for wind warranties. 6.3.2 6.3.3 6.3.4 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. Minimum Nailing - Berkshire® Hip & Ridge and High Ridge: Fig. 1 4 �— PrerailingWind Direction A Nails A 4 I I A I 4 I I I I I I i y W r Exposure Minimum Nailing - Hip & Ridge with Sealant: em Fig. 2 - High Wind Fastening Nuem (4 Bails) rim Shingle and Discard 2„ :JJ2Excess Sealant Strip 12" ' Fastenigg 55/s" Distance 5"Exposure 12" Fig. 2 Top View SideView Nails Nails � z Top Laminated z.. �� PisteV. I I I I 51 JI dl W I I I I I I Exterior Research and Design, LLC. Evaluation Report 037940.02.12 Certificate of Authorization #9503 FL10674-1116 Date of Issuance: 02/06/2012 Page 5 of 6 I, 6.3.5 Minimum Nailing — WeatherGuard® HP Hip and Ridge: Fig. A 4 4 Prevailing Wlnd t- DIredlon p A Nails q 4 A 44 A I I A I I I I P I I I I Exposure \-,.!TRINITY IERD Fig. C Hip & Ridge Shingle Fastening Top V I2%v Nails Nelis T 2 6„ Exposure 7. LABELING: 7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. S. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: Underwriters Laboratories — QUA1743; (414) 248-6409; karen.buchmannoul.com - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Certificate of Authorization #9503 Evaluation Report 037940.02.12 FL10674-R6 Date of Issuance: 02/06/2012 Page 6of6