HomeMy WebLinkAboutSUBMITTED PAPERSFEES � RECEIPT #: _.' Permit #:
Planning & Development Services Department
Building & Code Regulation Division
d�"'= 2300 Virginia Avenue
Ft. Pierce, FL 34982-5652 n l n
Tel.772-462-1553 SCANNEO
APPLICATION FOR ROOF PERMIT BY
SEE REVERSE SIDE FOR INSTRUCTIONS
1. Location/Site Address: b RD is S I=M 1 /JO L)✓ iZ'E> St LIICIG Cni inty
2. Parcel ID Number: 13 O I - & d'S- O 14 -0 oo -- 3
Office Use
Only
Section
Township
Range
Map Page
in
L
Use
I Ini ' s
3. Description of Project or Work Activity:
4. Total Roof Area (square feet):
6. Type of Roof:
] Fiberglass Shingle
] Tar & Gravel
OAF A Nb R C 906 P
5. Roof Pitch: i�2.� [ 2—
[ ] Concrete Roof Tile
;] Modified Bitumen
[ ] Wood Shake / Shingle
[ ] Other
N Product Approval required for all types of Roofing Material (2 Sets)
[ ] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product
Approval attached
** Roof Mitigation per F.S. 553.844 will be required.
7. Owner Information 8. Contractor Information
Name: Mt CH A L 442T I CA
Address: 5D (o S �M I AI ® L, T "61
City: FbCr P I oW E State: �7 L
Zip: 3 y g S I Phone: I CC-,
9. Value of Construction: $ a 6 O 5
FL Reg/Cert #: CCC 133005
County Cert #: -9 7,{ I q
Business Name: 502OkA iEoQHA6,urC
Cell Phone: -7-7Z - 559 -544q
"Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval.
CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all of the
PRINT QUALIFIERS/OWNERS NAME SIGNATURE OF)
contained in this application is correct and that all work will be
ible laws regulating construction and zoning.
STATE OF FLORIDA, COUNTY OF �App V_I-L� l
ACKNOWLEDGED BEFORE MET7--;0
lQ DAY OF �(� 20�, BY
IS ONALLY KNOWN ME OR HAS PRODUCED `V■
TYPE OR PRINT NAME OF
Q14u 1 t3_el.1
i 61 ScNQ ka
Notary Public iate ol l)ct 25!0rida
2013
My Co&u Pres
Commission # DD 926615
NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE
FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
Revised 4/26/2010
JOSEPH E. SMITH, CLFRT, OF THE CIRCUIT COURT - SAINT LUCIE 9TY
FILE # 3767518 OR, `K 3451 PAGE 2674, Recorded 11/08/2( at 12:07 PM
NOTICE OF COMMENCEMENT
TO BE COMPLETED WHEN CONSTRUCTION VALUE EXCEEDS $2,500.00
OR WHEN HEATING OR AIR CONDITIONING REPAIR OR REPLACEMENT EXCEEDS $7,500.00
PERMIT #: TAX FOLIO#: 1301- 605.014 8 - 000 - 3
State of Florida, County of Indian River, the undersigned hereby gives notice that Improvement will be made to certain real property, and In
accordance with chapter 713, Florida statutes, the following Information is provided in this notice of Commencement.
1. LEGAL DESCRIPTION OF PROPERTY (AND STREET ADDRESS IF AVAILABLE):
L*eWaoc) Pa r- Un4t 5-AL-Ky5 Loi 26 lir 19/rA IN)(e755-2359)5 ESeminole Qd
k
2. GENERAL DESCRIPTION OF IMPROVEMENT: I" Pierce FL 3g951-1 n0
., . —
3. ❑OWNER INFORMATION or ❑LESSEE INFORMATION (If Lessee contracted for the Improvement)
a. Name: Mi.-hael kirrtjca
Address: SRnt- F- Sevl;nol P iq
b. Interest in property: — �:,vr_
c. Name and address of fee simple title
(if other than owner):
4. CONTRACTOR:
a. Name: C-
Address• .&5002-16 vexes Rnyelq I= L 37-9(,5
b. Phone number: (772) 79N - 0(,82-
5. SURETY COMPANY (IF Applicable, a copy of the payment bond Is attached):
a. Name & Address:
b. Phone number., Bond amount:
6. LENDER/MORTGAGE COMPANY:
a. Name & Address:
b. Phone number:
7. PERSONS WITHIN THESTATE OF FLORIDA DESIGNATED BY OWNER UPON WHOM NOTICES OR OTHER DOCUMENTS MAY BE
SERVED AS PROVIDED BY SECTION 713.13 (1) (a) 7., FLORIDA STATUTES:
a. Name & Address:
b. Phone number: fax number:
B. IN ADDITION TO HIMSELF OR HERSELF,
a. Owner designates of to receive
a copy of the lienor's notice as provided in section 713.13(1) (b), Florida statues.
b. Phone number:
9. EXPIRATION DATE OF NOTICE OF COMMENCEMENT.
(THE EXPIRATION DATE IS ONE (1) YEAR FROM THE DATE OF RECORDING UNLESS A DIFFERENT DATE IS SPECIFIED(.
WARNING TO OWNER:
ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713,
PART 1, SECTION 713.13, FLORIDA STATUTES AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY, A NOTICE OF COMMENCEMENT
MUST BE RECORDED AND POSTED ON THE JOD SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR TENDER OR AN
ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE Of COMMENCEMENT.
UNDER PENALTIES OF PERJURY, I DECLARE THAT I HAVE READ THE FOREGOING AND THAT THE FACTS IN IT ARE TRUE TO THE BEST OF MY
KNOWLEDGE AND BELIEF (SECTION 92.525, FLORIDA STATUTES
1
SIGNATURE OF OWNER or LESSEE or OWNER'S AUTHORIZED OFFICER/DIRECTOR/PARTNER/MANAGER
SIGNATORY'S TITLE/OFFICE
THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME THIS 29 EL' DAY OF Q fober 20,1 BY:
AS FOR
NAME OF PERSON TYPE Of AUTHORITY' NAME OF PARTY ON BEHALF OF WHOM INSTRUMENT WAS EXECUTED
BFERSONALLY KNOWN „OR OPRODUCED IDENTIFICATION TYPE OF IDENTIFICATION PRODUCED
NOTARY SIGNATURE / v NOTARY PRINTED NAME. NW,PuB1,MYSEAL,.DW
MYCantu. EC.is I DD 9RS720
STATE OF FLORIDA
9T. LUCIE COUNTY
THIS ISTO CERTIFYTHATTHIS ISA
TRUE AND CORRECT COPY OF THE
ORIGINAL.
J :Ph = MITH, ERK
�y.
I-� J era
®aka: � 0
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34982
772-462-2165 or 772-462-2172
Fax: 772-462-6443
ROOF INSPECTION AFFIDAVIT
Re: Permit # 1 Z 11 - Gl OF?
I, 'D an"P I So roLaz- licensed as a(n)(ontractor /Engineer/Architect
(Please print name & circle license type) *FS468 Building Inspector
*General, Building, Residential or Roofing Contractor or any individual certified under 468 F.S. to make such an inspection.
On or about 11 - 2 - 11 , 1 did personally inspect the roof deck nailing
(Date)
work at: 5YUP 6 . Sem;,,)1e_ r.F�✓� Pie,-ce_ hu 3,1q S 1.
(job site address)
Based upon that examination ha a determined the installation was done according to the current_
edition of the Florida Existing B 1 ing Code Section 611 or the product approval submitted (whichever is
most stn ent).. '
sec 1330005
Signature and S License #
STATE OF FLORIDA I r
COUNTY OF ` /
Sworn to and subscribed before me this day of `fihcc 20j,),—
by �_ yS-((oKo Who isCprsonally kno to me or who has produced
,as identification.
Notary Public, State of Florida; i
Signature of N'bta f ;� ; "'PA P�b1, JACKIE D DUNGAN
g ry: ; iope- , •: Notary Public - State of FloridaCommission Num er: / " - /S (Seal) ?•My Comm. Expires Apr 30, 2015Commission # EE 84154
F
En 01/19/2011 "�..... � Bonded Through National Notary Assn.
Florida Building Code Online 3
w
License efficiently. Regulatefaidy.
ar_X.
CAI`.%iim
.i.' .
�.a
Product Approval
USER: Public User
FILC k0upy
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who
developed the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
FL1654-R11
Editorial Change
2010
Approved
POLYGLASS USA
150 Lyon Drive
Fernley, NV 89408
(570) 384-1230 Ext 242
jakins@polyglass.com
James Akins
jakins@polyglass.com
CONCEALED FASTENERS ORATTACHklM
James Arnold, PE, RRO
ARE THE RESPONSIBILITY OF THE
10475 Park Meadows Drive
CONTRAGTOROFRECOI�
Suite 600
Lone Tree, CO 80124
(720) 279-2348
jarnold@polyglass.com
James Akins
ST, LUCIE COUNTY
555 Oakridge Road
BUILDING DIVI N
Humboldt Industrial Pkwy
REVIEWO
Hazleton, PA 18201
(800) 894-4563
R
jakins@polyglass.com
DATE
PLANS OND PERMIT
Roofing
MUST BE KEPT ON JOB OR
Modified Bitumen Roof Svst
NO INSPECTION WILL BE MADE
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Q Evaluation Report - Hardcopy Received
Robert Nieminen
PE-59166
U L LLC
08/08/2015
John W. Knezevich, PE
THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
0-00
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvgqu2w%2bnFgUPv2pw6pK... 11 /21 /2012
Florida Building Code Online -
I
3
i.l Validation Checklist - Hardcopy Received
Certificate of Independence FL1654 R11 COI Trinity ERD CI - Nieminen.pdf
Referenced Standard and Year (of Standard) Standard Year
ASTM D6163 2000
ASTM D6164 2005
ASTMD6222 2002
FM 4470 1992
FM 4474 2004
Equivalence of Product Standards
Certified By
CSections from the Code �ILE
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Method 1 Option D
08/24/2012
08/24/2012
08/27/2012
10/09/2012
Summary of Products
FL # 11Model,
Numb
IDescrintion
1654.1
Polyglass SBS and APP
SBS and APP modified bitumen roof systems
Modified Bitumen Roof
Systems
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL1654 Rll II Al ER08212012FINAL POLYGLASS MODBIT FL1654-
R11.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-622.5
Created by Independent Third Party: Yes
Other: 1.) The design pressure in this
Evaluation Reports
application relates to one particular
FL1654 R11 AE ER08212012FINAL POLYGLASS MODBIT FL1654-
R11.pdf
assembly over concrete deck. Refer to the
ER Appendix for other systems and deck
Created by Independent Third Party: Yes
types. 2.) Refer to ER, Section 5 for other
Limits of Use.
Back Next
Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not
send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395.
*Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department
with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public
record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.
To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
http://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgvgqu2w%2bnFgUPv2pw6pK... 11 /21 /2012
((' l( "Ilk BUILDING PLANNING
FILEf"114"I PY
%0%0 .
TABLE R301.2(2)
COMPONENT AND CLADDING LOADS FOR A BUILDING WITH A MEAN
'. .wevnnCrl0= R 1nefl0. b, C. d,o
ROOF HEIGHT L)F 30 FEE i LOGA, cv 1-
Ultimate Design Wind Speed V„I�(mph
EFFECTIVE
_
WIND
AREA
115
120
130
140
150
160
180
200
23.7
=58.3
29.3 -72.0
ZONE
feet
110
4G.1
8.9
9.7
-23.8
10.5 -25.9
12.4 -30.4
14.3 -35.3
16.5
40.5
18.7
-21.8
^_1.3
9.1
-23.2
9.9 -25.2
11.6
-29.6
13.4 -34.4
15.4
-39.4
17.6
-44.9
22.2
-56.8
27.4 -70.1
l
20
SU - -
_3.3
7.6
20.5
8.3
_22.4
9.0
24.4
10.6
28.6
12.3 -33.2
14. ]
-38.1
16.0
43.3
20.3
54.8
25.0 -67.7
8.3
9.3
-27.8
11.4 -32.3
13.0
-37.0
14.8
-42.1
18.8
-53.3
23.2
-65.9
7.7
m
I
loo
7.0
-19.9
-21.8
__23.7
1(1.5
43.5
-51.0
14.3 -59.2
16.5
67.9
18.7 .
-7�7
23.7
97.8
29.3 -120.7
22.2
-87.4
27.4 -107.9
r`
2
_ 10
89
36.5
9.7
39.9
_12.4
13.4_
-52.9
15.4
-60.717.6
-69.0
0
2
20_
9.3
-32.6
9.1__-35.7
_-30.1
9.9 _-38.8_
1I.G
-45.6
14.1
16.0
-58.2
20.3
-73.6
25.0
-90.9
2
_
50
7.G
]7.5
8.3
9.0
-32.7
10.6
-38.4
1.23
-44.5
-51.1
18.8
63.2
23.2
-78..1
-
2
IUO
7.0
3.6
7.7
-25.8
8.3
-28.1
9.8
-33.0
11.4
-38_2
13.0
-43.9
14.8
_`0
a
23.7 °'147.2
29.3 -181.7
cc
-- 10_-
R9
55.0
9.7
21.8
10.5
65.4
12.4
76.R
14.3
-R9.0
16.5
-102.2
18.7
3
-�._ ---
9.l
21.2
9.9
543
11.6
-63.6
13.4
-73.8_
15.4
-84.7
17.6
-96.3
222
-121.9
27.4 -150.5
p
-
�p
R:3
45.5
20.4
9.0 _-39.3
10.6
-463
123
53.5
14.1
61.5
16.0
69.9
20.3
88.5
25.0 _109.3
3-
50
-
7.6
33.1
3.3
9.8
33.0
11.4
-38.2
13.0
-43.9
14.8
50.0
18.8
63.2
23 L
-78-
3
100
7.0
23.G
7.7
19.8
8:3
14.9
-28.1
-23.7
17.5
-27.8
20.3
-32.3
23.3
37.0
28.5
°-42.1
33.6_
-53.3
41.5
-65.9
1
_
--10
12.5
-199
13.7
-37`9
-64.0
- -
- - -- -
18.5
21.3.
-36.0
24.2
41.0
51.9
37.8
w
I
20
11.4
-19.4
12�5
-34.9
13.6
-23.0
16.0
-27.0 _
-31.4
18.5
21.1
-39.4
_30_6
26.7
-49.9
32.9
-61.6
1
50_---
10.0
18.6
10.9
30.9V4L9-1
22.2
13.9
-26.0
16.1
-30.2 _
-34.6
23.7
4R.4
-59.8
d
rn
--
8.9
-18.1
9.7
27.R
21.5
12.4
25.2
14.3
-293
16.5
33.G
18.7
-33.2
°-73.4
33.G
92.9
41.3
41.5
-114.6
m
-
10
12.5
177
-56.0-41.3
_ 17.5
48.4
20.3
-56.2
23.3
64.5
26.5
n
2
- ___
_-34.7
38.0
16.0
44.6
I8.5
-5 L7
21.3
59.324.2
67.5
30.6
85.4
37.8-105.5
0
2 _
20 -_
_11 4
-31.9
I2.5
_-52.4
13.9
39.4
IG.1
45.7
18.5
52.5
21.1
-59.7
26.7
75.6
32.9
-93.3
n2
SU
10.0
28 L
10.9
47.6
-33.6_
14.3
-41.2
16.5
-47.3
18.7
-53.9
23.7
68.2
29.3
-84.2
A
o
2
100
R.9
-25.5
_
9.7
44.0
-30.3
12.4
-35.6
26.5
�103.5
33.6
137.3
41.5
-169.5
_
_
10
12.5
-51.3
13_7
-23.8
14.9
-6 1.01.0
17.5
-71..6
20.3
-83. I
23.3
95.4
e
- 3
-
13.6
-57.1
16.0
-67.0
18.5
-77.7
21.3
-89.2
24.2
-101.4
30.6
-128.4
37.8
-158.5
3
-- 20--_
11.-1
-47.9
12.5_
-22.6
13.9
60.8
16.1
70.5
18.5
-81.0
21.1
92.1
26.7
116.E
_32.9
-143.9
3
50
10.0
43.5
10.9
21.0
11.9
51.8
16.5
-74.8
18.7
-85.1
23.7
-107.7
- 32.9
3_
100
_8
- -40.2
_ 9.7
-19.8
10.5
-47.9
12.4
56.2
14.3
-65.1
46.1
53.3
58.3
65.3
65.9
72.0
-72.0
_
_ _
19.9
21.3
21.8
-27.6
23.7
25.9
27.8
-30.4
32.3
-35.3
37.0
40.5
42.1
64.0
-68.3
19 9
-20.7
21.2
-27.6
23.0
24.6
27.0
-28.9
31.4
-33.5
36.0
-38.4
41.0
-43.7
51.9
-55.3
1
20
_
22.2
-22.8
26.0
-26.8
30.2
-31.1
34.6
35.7
39.4
40.6
49.9
51.4
61.6
-63.4
aNi
`
I
50
19.6
-
-I9.2
20.4
-25.0
21.5
25.2
25.2
29.3
-29.3
33.6
33.6
38.2
-
48.4
-48.4
59.8
-59.8
1 -
2
100
--
10
18.1
19.9
-18.1
_
-25.5
19_8
21.8
--23.8
-27.R
_21^5
23.7
3U.3
27.8
35.6
32.3
-41.2
37.0
47.3
42.1
53.9
53.3
68.2
65.9
64.0
-84.
-80.5
__
27.0
34.0
31.4
-39.4
36.0
-45.3
41.0
-51.5
51.9
-65.2
a
^ 2
20
-_ -_
19.4
24.3
21
26.6
23.0
29.0
30.2
34.6
-42.5
39.4
-46.1
49.9
61.3
61.8
-72.0
N
2
50
18.6
_ -22.9
20.4
-25.0
22.2
-27.2
26.0
-32.0
-37.1
38.2
46, I
48.4_
-58.3
59.8
-72.0
2
100
18.1
-21.8
19.8
-23.8
21.5
25.9
25.2
30.4
29.3
-31.3
33.6
-40.5
53.3
68.2
65.9
-84.2
0
-
19.9
25.5
21.9
27.8
23.7
-30.3
27.8
-35.6_
32.3
-41.2
37.0
47.3
42.1
¢
3
!0
-
-
23.0
-29.0
27.0
-34.0
31.4
-39.4
3G.0
45.3
41.0
-51.5
51.9
65.2
64.0
-80.5
- -
3
_ 20
19.4
_24.3
211
_26,6
26.0
30.2
-37.1
34.6
-42.5
39.4
-4R.4
49.9
-61.3
61.6
-75.6
3'_
_ 50
'
18_6
•-22.9_
20.4
-25.0
22.2
-27.2
-32.0
33.6
-40.5
38.2
-46.1
48.4
-58.3
59.8
-72.0
3
I00
lR.l
21.R
19.8
23.6
21.5
25.9
25.2
-30.4
29_3
-35.3
46.1
50.0
58.3
G3.2
72.0
-78.1
4
10
21.3
23.6
23_3
25.8
25.9
28.1
30.4
-33.0
35.3
-38.2
40.5
-43.9
55.7_
68.7
_
-74.8
24.7
26.9
29.0
31.6
33.7
-3G.7
38.7
42.1
44.0
47.9�
-60.6
�57.1
64.4
-70.6
q
20
20.8
'2.6
23.7
24.7
_ _
19.5
21.3
2l_3
23.3
23.2
-25.4
27.2
-29.8
31.6
-34.6
36.2
-39.7
41.2
45.1"°
52.2
q
4
_g0__
_ 100
1 R.5
1G.2
20.4
18.1
20.2
17.7
22.2
-19.8
22.0
19.3
24.2
-21.5
25.9
22.7
-28.4
-25.2
30.0
26.3
-33.0
_29.3
34.4
30.2
-37.9
-33.6
39.2
34.3
-43.1
38.2
°„...
49.6
43.5
54.5
48.4
61.2
53.7
-67.3
-59.8
4
500 _
- -
_
30.4
35.3
-47.2
40.5
54.2
46.1
6 .7
5R.3
-78.8
31
-89.9
5
10 -
_21.8
29.1
_-27.2
23.8
-31.9
25.9
-34.7
-40.7
38.7
44.0
-57.5
55.7
72.8
G8.7
68.7
-89.9
�5
20
20.8
22.7
-29.7
24.7
-32.4
29.0
-38.0
33.7_
-44.0
-50.5
52.2
65.8
64.4
-81.3
50�
19.5
-24.6
21.3
-26.9
23.2
-293
273
-34.3
31.6
-39.8
36.2
-45.7
41.2
-52.0
5
5
100 _
18.5
-22.G
2� 2_
-24.7
22.0
.26.9
25.9
-31.6
30.0
-36.7
34.4
42.1
39.2
34.3
47.9
3R.2
49.6
43.5
60.6
48.4
61 1
53.7
-74.8
-59.8
17.7
-19.8
19.3
-21.5
22.7
-25.2
26.3
-29.3
302
33.6
---
-- -
----
16.2
-1R.1
0
0479 IcPa
For SI: I fool = 304.8 min, J square foot = 0.0929 m . 1 mile per hour = 0.447 m/s, I pound per square foot = .
Notes:
a. The effective wind area shall be equal to the span length multiplied by an effective width. This width shall be permitted to be not be less than one-third the span
length. For cladding fasteners, the effective wind area shall not be greater than the area that is tributary to an individual fastener.
b. For effective areas between those given above, the load may be interpolated; otherwise, use the load associated with the lower effective area.
c. Table values shall be adjusted for height and exposure by multiplying by the adjustment coefficient in Table R301.2(3).
d. See Figure R301.2(7) for location of zones.
e. Plus and minus signs signify pressures acting toward and away from the building surfaces.
f. Positive design wind pressures shall not be less than +t6 psf and negative design wind pressures shall not be less than -16 psf.
3.3
2010 FLORIDA BUILDING CODE - RESIDENTIAL '
r Ma
9TR'
• .
APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE
Table
Deck
Application
Type
Description
Page
1A-1
Wood
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
4
IA-2
Wood
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
5
iB
Wood
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
6
1C
Wood
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
6
1D
Wood
New, Reroof (Tear -Off) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
7
1E
Wood
New or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
8-9
1F
Wood
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
9
2A
Steel or Conc.
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
10
2B
Steel or Conc.
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
10
2C
Steel or Conc.
New, Reroof (Tear -Off) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
11
3A-1
Concrete
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
12-15
3A-2
Concrete
New or Reroof (Tear -Off)
A-1
Bonded Temporary Roof, Bonded Insulation, Bonded Roof Cover
16
3B
Concrete
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
17
4A
LWIC
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
18-19
4B
LWIC
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
19
4C
LWIC
New or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
20-23
5A
CWF
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
24
5B
CWF
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
25
5C
CWF
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
25
5D
CWF
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
26
5E
CWF
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
26
6A
Gypsum
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
27
6B
Gypsum
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
28
6C
Gypsum
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
28
6D
Gypsum
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
28
7A
Various
Recover
A-1
Bonded Insulation, Bonded Roof Cover
29-30
7B
Various
Recover
F
Non -Insulated, Bonded Base Sheet, Bonded Roof Cover
30
The following notes apply to the systems outlined herein:
1. Roof decks shall be in accordance with FBC requirements to the satisfaction of the AHJ. Wind load resistance of the roof deck shall be documented through
proper codified and/or FBC Approval documentation.
2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement:
➢ Wood: Minimum 0.75-inch penetration.
➢ Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck.
➢ Concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions.
3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, DensDeck, DensDeck
Prime, DensDeck DuraGuard, SECUROCK Gypsum -Fiber Roof Board or SECUROCK Glass -Mat Roof Board that meets the QA requirements of F.A.C. Rule
9N-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC 2603.4.1 or 2603.6, when installed with the roof cover.
Exterior Research and Design, LLC. d/b/a TrinitylERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report P9290.02.08-R9 for FL1654-R11
Revision 9: 08/21/2012
Appendix 1, Page 1 of 30
A
INI
ER
APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE
Table Deck Application Type
Description
Page_
1A-1
Wood
New or Reroof (Tear -Off).
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
4
1A-2
Wood
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
5
1B
Wood
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
6
1C
Wood
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
6
1D
Wood
New, Reroof (Tear -Off) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
7
I
Wood
New or Reroof .(Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
8-9
1F
Wood
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
9
2A
Steel or Conc.
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
10
2B
Steel or Conc.
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof cover
10
2C
Steel or Conc.
New, Reroof (Tear -Off) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
11
3A-1
Concrete
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
12-15
3A-2
Concrete
New or Reroof (Tear -Off)
A-1
Bonded Temporary Roof, Bonded Insulation, Bonded Roof Cover
16
3B
Concrete
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
17
4A
LWIC
New or Reroof (Tear -Off)
A-
Bonded Insulation, Bonded Roof Cover
18-19
4B
LWIC
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
19 .
4C
LWIC
New or Reroof (Tear -off)
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
20-23
5A
CWF
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
24
5B
CWF
New, Reroof .(Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
25
5C
CWF
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
25
5D
CWF
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
26
5E
CWF
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech: Attached Base Sheet, Bonded Roof Cover
26
6A
Gypsum
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
27
dz 68
Gypsum
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, 'Bonded Insulation, Bonded Roof Cover
28
m
6D Gypsum New, Reroof (Tear -Off) or
7A Various Recover
7B Various Recover
A-1 Bonded
F Non -Ins
Insulation, Bonded Roof Cover
Mech. Attached Base Sheet, Bonded Roof
on, Bonded Roof Cover
Bonded Base Sheet, Bonded Roof Cover
28
wid The following notes aaioly to the systems outlined herein:
M 1. Roof decks shall be in accordance with FBC requirements to the satisfaction of the AH]. Wind load resistance of the roof deck shall be documented throug
CO3�
roper codified and/or FBC Approval documentation.
2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement:
Wood: Minimum 0.75-inch penetration.
3_ 0
"r Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck.
Y Concrete: Minimum 1-inch embedment Into pilot hole in accordance with fastener manufacturer's published installation instructions.
3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, DensDeck, DensDec
Prime, DensDeck DuraGuard, SECUROCK Gypsum -Fiber Roof Board or SECUROCK Glass -Mat Roof Board that meets the QA requirements of F.A.C. Rul
911-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC 2603.4.1 or 2603.6, when installed with the roof -cover.
Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report P9290.02.08-119 for FL1654-R11
Certificate of Authorization #9503 Revision 9: 08/21/2012
Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 1 of 30
TRINITY ! !ERD
4. Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D (mechanically
attached base sheet, bonded roof cover), whereby the base sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck.
The structural deck shall be of equal or greater configuration to the steel and concrete deck listings.
5. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall
expand as noted in the manufacturer's published instructions.
➢ HA (HA): Full coverage at 25-30 Ibs/square.
➢ Dow Insta-Stik Roofing Adhesive (D-IS): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c.
➢ Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c.
➢ OMG OlyBond 500 (OB500): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. (PaceCart or SpotShot). Note: OlyBond Green may be used
where OlyBond 500 is referenced.
➢ OlyBond Classic (OB Classic): Full coverage at 1 gal/square.
➢ 3M CR-20: Continuous 2.5-3.5-inch wide ribbons, 12-inch o.c. Note: 77TESET may be used where CR-20 is referenced.
➢ Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon -applied adhesive, adhesive ribbons shall be staggered from layer -to -layer a distance of
one-half the ribbon spacing.
➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing.
6. Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanu rate at the following thickness
limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to increase' the MDP
listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may
be used as a drop -in for the equivalent thicker material listed in the table:
➢ Millennium One Step Foamable Adhesive (M-OSFA): MDP -157.5 psf (Min. 0.5-inch thick)
➢ OMG OlyBond 500 (OB500): MDP -45.0 psf (Min. 0.5-inch thick Multi -Max FA-3)
➢ OMG OlyBond 500 (013500): MDP -187.5 psf (Min. 0.5-inch thick ISO 95+ GL)
➢ OMG OlyBond 500 (O13500): MDP -315.0 psf (Min. 0.5-inch thick ENRGY 3)
➢ OMG OlyBond 500 (013500): MDP -487.5 psf (Min. 0.5-inch thick ACFoam II)
➢ 3M CR-20: MDP -117.5 psf (Min. 1.0-inch thick)
7. Bonded polyisocyanu rate insulation boards shall be maximum 4 x 4 ft.
„ 8. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the
r° Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified
design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117 and FM LPDS 1-29. Assemblies marked with an
asterisk* carry the limitations set forth in Section 2.2.1.5.1(a) of FM LPDS 1-29 for Zone 2/3 enhancements.
9. For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in
accordance with FBC Chapter 16, and no rational analysis is permitted.
10. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design
professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105
or ANSI/SPRI FX-1.
11. For existing substrates in a bonded recover installation, the existing roof system shall be examined for compatibility and bond performance with the
selected adhesive, and the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the AHJ, as
documented through field uplift testing in accordance with ASTM E907, FM LPDS 1-52, ANSI/SPRI IA-1 or TAS 124.
12. For Recover Applications using System Type D, the insulation is optional; however, the existing roof system shall be suitable for a recover application.
Exterior Research and Design, L-C. d/b/a TrinitylERD Evaluation Report P9290.02.08-R9 for FL1654-R11
Certificate of Authorization #9503 Revision 9: 08/21/2012
Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 2 of 30
TABLE 1E: WOOD DECKS - NEW CONSTRUCTION or REROOF (Tear -Off)
SYSTEM TYPE E: NON=INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
Base Sheet
Roof Cover
No.
Roof Deck
MDP (psf)
Base
Fasteners
Attach:
Ply
Cap
Min. 19/32-inch plywood at
32 ga., 1-5/8-inch diameter
6-inch o.c. in 4-inch lap
(Optional) One or
W-30
max. 24-inch spans attached
Elastobase or Elastobase Poly
tin caps with 11 ga. annular
and 6-inch o.in four,
,
more BP -AA ,
SBS-AA , SBS-
-112:5
6-inch o.c. with #8 screws
ring shank nails
equally spaced,
SBS-AA, SBS-TA
TA, APP-TA
staggered center rows
or APP-TA
32 ga., 1-5/8-inch diameter
(Optional) One or
Min. 19/32-inch plywood at
Elastobase or Elastobase Poly with poly
tin caps with 11 ga. annular
6-inch o.c. In 4-inch lap
and 6-inch o.c. in four,
more SBS-SA (no
Elastoflex SA V
SBS-SA, APP-
W-31
max. 24-inch spans attached
top surface
ring shank nails. Note: Tin
equally spaced,
Base orEfastoflex
SA, SBS-TA or
-112.5
6-inch o.c. with #8 screws
caps are to be primed with
staggered center rows
SA V FR Ease),
APP-TA
PG100 or ASTM D41 primer.
SBS-TA or APP-TA
TABLE IF: WOOD DECKS - NEW CONSTRUCTION or REROOF (Tear -Off)
SYSTEM TYPE F: NON -INSULATED, BONDED ROOF COVER
Roof Cover
System No.
Deck
Primer
MDP (psf)
joint Treatment
Ply
Ca
Min..19/32-inch plywood at
W 32
max. 24-inch spans; attached, 6-
Optional) PG100
None'
$8S-SA.
(Optional) SBS-SA,
SBS-SA, APPSA;
_900>
Inch o.c. with 8d ring,shank
SBS-TA or APP-TA
SBS--TA- or, AP.P-TA-
nails'
Min. 15/32-inch plywoo a
Plywood joints are covered with 4-inch
Elastoflex SA V
al) SBS-SA,
(Optional)
l)
SBS-SA, APP-SA,
W-33
max. 24-inch spans attached 6-
(Optional) PG100
wide strips of Elastoflex SA V Plus, rolled
Base or Elastoflex
-97.5
inch o.c. with #12 screws
into place to create continuous bond.
SA V FR Base
SBS -TA APP-TA
SBS-TA or APP-TA
Min. 15/32-inch plywood at
Plywood joints are covered with 4-inch
Elastoflex SA V Plus
(Optional) SBS-SA,
SBS-SA, APP-SA,
W-34
max. 24 inch spans attached 6-
p
(Optional) PG100
wide strips of Elastoflex SA V Plus, rolled
or Elastoflex SA V
-135.0
Inch o.c. with #12 screws
into place to create continuous bond.
Plus FR
SBS-TA or APP-TA
SBS-TA or APP-TA
Exterior Research and Design, LLC. d/b/a TrinitylERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report P9290.02.08-R9 for FL1654-R11
Revision 9: 08/21/2012
Appendix 1, Page 9 of 30
OP
Joe Cicio
From:
Sent:
To:
Subject:
Attachments:
Mr Cicio,
Re: permit 1211 -0 100
Daniel Soroka <sorokaroofing@att.net>
Monday, November 19, 2012 2:32 PM
Joe Cicio
product approval for Hrtica
flat deck 001 jpg; flat deck 002 jpg
Attached are the pages of the system to be used on Mr Hrtica's flat roof.
I do believe I gave you the entire product approval for these Polyglass materials, these two pages
need to be changed with the original pages.
Please disreguard the certinteed approval. if you have any questions pleasa call me at 772-559-5844.
Thank you,
Dan
Soroka Roofing, LLC
De�
7KOV 2 0 2012 D
1
Planning & Development Services
Building & Code Regulation Division
Permitting Department
2300 Virginia Avenue
Fort Pierce, FL 34982
Phone: (772) 462-1553 Fax: (772) 462-1578
PROPERTY INFORMATION
Address: 5806 SEMINOLE RD
City / State / Zip: FORT PIERCE
Parcel # : 1301-605-0148-000/3
Zoning: RS-4
APPLICATION INFORMATION
Permit Number: 1211-0100
Activity Type:
Permit Type: Roof
CONTRACTOR INFORMATION
Contractor Name: SOROKA, DANIEL J
Business Name: SOROKA ROOFING LLC
Business Addr: P.O. BOX 650026
Review Comments
Owner(s):
Michael Hrtica
FL 34951
Jurisdiction: St. Lucie County
Lot # : 26 Block: 45
Page 1
Application Type: Over the Counter Permit
Other Activity:
Stories: 1 Automatic Sprinkler System?
City / State / Zir VERO BEACH, FL 3296
REVIEWS AND COMMENTS
Review Type Status Reviewed By
Front Counter Review Complete Angela Huff
Plans Examiner Review Incomplete
Fax Number 772-794-0682
ST, LUCIE COUNTY B G DIVISION
Pre -Reviewed Not In trance
Reviewe
No, 5�/2
Date Started Date Complete Date Released
11/08/2012
Joe Cicio 11/15/2012
11/15/2012 1 Comment YOU HAVE SUBMITTED 2 DIFFERENT PRODUCT APPROVALS FOR THIS ROOF * CONTRACTOR
TO DETERMINE WHICH PRODUCTAPPROVAL IS TO BE USED AND IF USING N.O.A. PLS STATE
THE SYSTEM TYPE PROPOSED *
11/15/2012 2 Commenl WITHIN THE FLORIDAAPPROVAL CONTRACTOR TO REVIEW LIMITATIONS 5.6 AND 5.8 FOR
MECHANICALLY ATTACHED BASE SHEETS * SUBMIT ENGINEERS REPORTS FOR PULL TEST
AND DESIGN PRESSURE CONFORMANCE TO THE PRODUCTAPPROVAL SUBMITTED.
11/15/2012 3 Comment COMMENTS MAILED AND FAXED AS OF THIS DATE
To Be Review by Plans Exan Complete Joe Cicio 11/15/2012 11/15/2012
TRANSMISSION VERIFICATION REPORT
TIME 11/13/2012 11:09
NAME SLC CODE COMP
FAX 7724626448
TEL 7724622963
SER.# BROE5J278861
DATE DIME
11 / 13 11: 09
FAX NO./NAME
917727940682
DURATION
00:00:20
PAGE(S)
01
RESULT
OK
MODE
STANDARD
ECM
Planning & Development Services
Building & Cade Regulation Division
Permitting Department
2300 Virginia Avenue
Fort Pierce, FL 34982
Phone: (772) 462.1653 Fax: (772) 4624578
PROPERTY INFORMATIf;NV
Address: 5806 SEMINOLE RD
City 1 State 1 Zip: FORT PIERCE
Parcel # : 1301-$0$-0148.00013
Zonfng: RS-4
APPLICATION INFORMATION
Permit Number: 1211-0100
Activity type:
PormitType: Roof
Contractor Name: SOROKA, DANIEL J
Business Name: SOROKA ROOFING LLC
Business Addr: P.O. BOX 650026
R£YI@W Comments
Owner(s):
Michael Hrtica
FL 34951
Jurisdiction: St, Lucie County
Lot # : 26 Block: 45
Page 1
Application 7Wm., Over the Counter Permit
OtherActivity:
$tortes: 1 Automatic Sprinkler System? El
City I stpte I ZiK VERO BEACH, FL 3296
REVIEWS AND COMMENTS
Review 7Vn0 Status Reviewed By
Front Counter Review Complete Angela bluff
Fax Number 772-794-0682
Data bate Comotete Date Released
11/0812012
Plans Examiner Review Incomplete Joe Cicio 11/1512012
Florida.:Building Code Online
3
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who
developed the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
FL2533-R8
Revision
2010
Approved
X
CertainTeed Corporation -Roofing
PO Box 1100
1400 Union Meeting Rd
Blue Bell, PA 19422
(215) 274-2350
Steven.T.Lawrey@saint-gobain.com
Steven Lawrey
Steven.T.Lawrey@saint-gobain.com
Steven Lawrey
1400 Union Meeting Road
Blue Bell, PA 19422
(215) 274-2425
Steven.T.Lawrey@saint-gobain.com
Roofing
Modified Bitumen Roof System
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Robert Nieminen
PE-59166
UL LLC
06/09/2013
John W. Knezevich, PE
f.( Validation Checklist - Hardcopy Received
FL2533 R8 COI Trinity ERD CI - Nieminen.odf
http://www.floridabuilding. org/pr/pr_app_dtl. aspx?param=wGEVXQwtDgvwelwRFXRvHOHSbalV %2... 11 /15/2012
Florida -Building Code Online
C
Referenced Standard and Year (of Standard) Standard Year
ASTM D6163 2000
ASTM D6164 2005
ASTM D6222 2002
ASTM D6223 2002
ASTM D6509 2000
FM 4470 1992
FM 4474 2004
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Method 1 Option D
08/23/2012
08/24/2012
08/27/2012
10/09/2012
Summary of Products
FL #
IModel, Number or Name
Description
2533.1
Flintlastic Modified Bitumen
Modified Bitumen Roof Systems
Roof Systems
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL2533 R8 II Al er082312FINAL CERTAINTEED MODBIT FL2533-
R8.Ddf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nieminen, PE PE-59166
Design Pressure: +N/A/-630
Created by Independent Third Party: Yes
Other: 1.) Refer to ER Section 5 for Limits
Evaluation Reports
of Use. 2.) The design pressure noted in this
FL2533 R8 AE er082312FINAL CERTAINTEED MODBIT FL2533-
R8.Ddf
application relates to one specific system.
Refer to the ER Appendix for all systems and
Created by Independent Third Party: Yes
max design pressures.
Back Next
Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not
send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395.
*Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department
with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public
record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.
To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
in eClikiY, M
http://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgvweIwRFXRvHOHSbalV%2... 11 /15/2012
EVALUATION REPORT
CertainTeed Corporation
1400 Union Meeting Road
Blue Bell, PA 19422
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 Christian Street
Oxford, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
Evaluation Report 3520.03.04-R8
FL2533-R8
Date of Issuance: 09/19/2005
Revision 8: 08/23/2012
SCOPE:
This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing
the use of construction materials in the State of Florida. The documentation submitted has been
reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The
product described herein has been designed to comply with the 2010 Florida Building Code.
DESCRIPTION: Flintlastic® Modified. Bitumen Roof Systems
LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality
Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)
changes, the referenced Quality Assurance documentation changes, or provisions of the Code that
relate to the product change. Acceptance of this Evaluation Report by the named client constitutes
agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality
Assurance documentation changes. TrinitylERD requires a complete review of this Evaluation
Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words ."Trinity I ERD Evaluated"
may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then
it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by
the manufacturer or its distributors and shall be available for inspection at the job site at the
request of the Building Official.
This Evaluation Report consists of pages 1 through 5, plus a 43-page Appendix.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized
by Robert Nieminen, P.E. on 08/23/2012
This does not serve as an electronically signed
document. Signed, sealed hardcopies have been
transmitted to the Product Approval Administrator and
to the named client
CERTIFICATION OF INDEPENDENCE:
1. Exterior Research & Design, LLC. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a
financial interest in any company manufacturing or distributing products it evaluates.
2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company
manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing
products for which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval
process of the product.
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Modified Bitumen Roof Systems
Compliance Statement: Flintlastic@ Modified Bitumen Roof Systems, as produced by CertainTeed
Corporation, have demonstrated compliance with the following sections of the Florida Building Code
through testing in accordance with the following Standards. Compliance is subject to the Installation
Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1504.3.1
Wind
FM 4474
2004
1504.7
Impact
FM 4470
1992
1507.11.2
Physical Properties
ASTM D6163
2000
1507.11.2
Physical Properties
ASTM D6164
2005
1507.11.2
Physical Properties
ASTM D6222
2002
1507.11.2
Physical Properties
ASTM D6223
2002
1507.11.2
Physical Properties
ASTM D6509
2000
3. REFERENCES:
Entity
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
Examination
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
Physical Properties
FM 4470/4474
FM 4470/4474
FM 4470/4474
Physical Properties
Physical Properties
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
TAS 117(B), Rupture
FM 4470/4474
FM 4470/4474
Physical Properties
FM 4470/4474
FM 4470/4474
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
Reference
Date
3504.06.01-1
06/05/2001
3513.08.02
08/15/2002
03515.07.03
07/22/2003
3519.12.03
12/22/2003
3522.07.04
07/28/2004
02843.02.05-11
02/10/2005
3533.01.06
01/06/2006
4674.11.01-1
03/21/2006
3535.10.06
10/31/2006
3521.07.04-R1
10/26/2007
02764.09.05-R1
12/10/2007
02762.03.05-R1
12/10/2007
C7290.01.08
01/16/2008
C10080.09.08
09/04/2008
C8370.08.08-R1
10/05/2009
P6860.06.07-R1
09/10/2009
C30310.12.09
12/17/2009
C30560.03.10
03/18/2010
C33980.12.10
12/22/2010
C33830.02.11
02/08/2011
C35500.02.11
02/09/2011
C37820.07.12
07/24/2012
C37830.07.12
07/26/2012
C42110.08.12
08/13/2012
C39670.08.12
08/20/2012
C42280.08.12
08/20/2012
OE3A2.AM
03/30/1982
3WOA4.AM
03/16/1993
3 W OA2. AM
03/ 17/ 1993
3WOA3.AM
03/17/1993
1Z4A6.AM
09/11/1996
3Y8A1.AM
09/30/1996
2D5A9.AM
06/22/1999
3009502
12/12/2000
3008869
03/19/2001
3009610
10/15/2001
3006025
12/28/2001
3012321
07/29/2002
3009814
09/06/2002
Exterior Research and Design, LLC. Evaluation Report 3520.03.04-1118
Certificate of Authorization #9503 FL2533-118
Revision 8: 08/23/2012
Page 2 of 5
Entity
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
MTI (TST2508)
MTI (TST2508)
MTI (TST2508)
MTI (TST2508)
MTI (TST2508)
MTI (TST2508)
MTI (TST2508)
PRI(TST5878)
PRI(TST5878)
PRI(TST5878)
PRI(TST5878)
PRI(TST5878)
PRI(TST5878)
PRI(TST5878)
PRI(TST5878)
PRI(TST5878)
UL, LLC. (QUA9625)
4. PRODUCT DESCRIPTION:
Examination
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
FM 4470/4474
Physical properties
Physical properties
Physical properties
Physical properties
Physical properties
Physical properties
Physical properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Quality Assurance
Reference
3014502
3015444
3014692
3014751
3018579
3020703
3021759
3022038
3023458
3026128
3024311
3025766
3028410
3026964
3031262
3032172
3037127
3039848
DX08C4A
DX20E3A
DX20E3A-001
AX31G8A
AX31G8D
AX31G8F
AX21G8C
CTC-032-02-01
CTC-034-02-01
CTC-066-02-01
CTC-067-02-01
CTC-068-02-01
CTC-070-02-01
CTC-071-02-01
CTC-093-02-01
CTC-116-02-01
Service Confirmation, R11656
Date
04/04/2003
07/11/2003
08/05/2003
08/27/2003
10/09/2003
07/30/2004
06/03/2005
04/05/2006
07/18/2006
08/04/2006
11/01/2006
11/13/2006
02/19/2007
07/25/2007
11/30/2007
06/12/2009
01/11/2010
12/02/2011
03/22/2004
03/22/2004
01/04/2006
08/21/2008
09/05/2008
06/05/2009
01/28/2011
01/16/2008
11/24/2008
08/08/2011
08/08/2011
08/08/2011
08/08/2011
08/08/2011
08/08/2011
04/03/2012
Exp. 06/09/2013
This Evaluation Report covers Flintlasticp Modified Bitumen Roof Systems installed in accordance with
CertainTeed Corporation published installation instructions and the Limitations / Conditions of Use
herein. The following CertainTeed products make up the subject systems.
Table 1: Roll -Goods for Flintlasticp Modified Bitumen Roof Systems
Type
Product
Specification
Reference
Grade
Type
Base Sheets
Flintlasticp SA NailBase
ASTM D4601
N/A
II
Yosemitep Venting Base
ASTM D4897
N/A
II
Glasbase'" Base Sheet
ASTM D4601
N/A
II
All Weather/Em ireTm Base
ASTM D4601
N/A
II
Flexi IasTI Base
ASTM D4601
N/A
II
FlintlasticT" Base 20
ASTM D4601
N/A
II
Flintlastic Poly SMS Base Sheet
ASTM D4601
N/A
II
Ply Sheets
Flint lasp Ply Sheet Type IV
ASTM D2178
N/A
IV
Flint lasp Premium Ply Sheet Type VI
ASTM D2178
N/A
VI
Base/Ply Membranes (APP)
Flintlasticp APP Base T
ASTM D6509
N/A
N/A
Flintlasticp STA
ASTM D6222
S
I
Flintlasticp STA Plus
ASTM D6222
S
I
Cap Membranes (APP)
Flintlasticp STA
ASTM D6222
S
I
Flintlasticp STA Plus
ASTM D6222
S
I
Flintlasticp GTA
ASTM D6222
G
I
Flintlasticp GTA CoolStarT"
ASTM D6222
G
I
Flintlasticp GTA-FR
ASTM D6222
G
I
Flintlasticp GTA-FR CoolStarlm
ASTM D6222
G
I
Exterior Research and Design, LLC. Evaluation Report 3520.03.04-R8
Certificate of Authorization #9503 FL2533-118
Revision 8: 08/23/2012
Page 3 of 5
O
`J TRINITY I ERD
Type
Product
Specification
Reference
Grade
Type
Base/Ply Membranes (SBS)
Flintlastic@ SA PI Base
ASTM D1970
N/A
N/A
Flintlastic@ SA Mid Ply
ASTM D6164
S
I
Black Diamond(g) Base Sheet
ASTM D1970
N/A
N/A
Flintlastic@ Ultra Glass SA
ASTM D6163
S
I
Flintlastic@ Base 20
ASTM D6163
S
I
Flintlastic@ Base 20 T
ASTM D6163
S
I
Flintlastic@ FR Base 20 T
ASTM D6163
S
I
Flintlastic@ Ultra Poly SMS Base Sheet
ASTM D6164
S
I
Cap Membranes (SBS)
Flintlastic@ SA Cap FR
ASTM D6163
G
I
Flintlastic@ SA Cap FR CoolStar
ASTM D6163
G
I
Flintlastic@ SA Cap
ASTM D6164
G
I
Flintlastic@ SA Cap CoolStar-
ASTM D6164
G
I
Flintlastic@ Cap 30
ASTM D6163
G
I
Flintlastic@ Cap 30 CoolStar'
ASTM D6163
G
I
Flintlastic@ FR Cap 30
ASTM D6163
G
I
Flintlastic@ FR Cap 30 CoolStarTl
ASTM D6163
G
I
Flintlastic@ FR Cap 30 T
ASTM D6163
G
I
Flintlastic@ FR Cap 30 T CoolStarM
ASTM D6163
G
I
Flintlastic@ FR-P
ASTM D6164
G
I
Flintlastic@ FR-P CoolStarTl
ASTM D6164
G
I
Flintlastic@ GMS
ASTM D6164
G
I
Flintlastic@ GMS CoolStar-
ASTM D6164
G
I
Flintlastic@ GTS
ASTM D6164
G
II
Flintlastic@ GTS CoolStar
ASTM D6164
G
II
Flintlastic@ GTS-FR
ASTM D6164
G
II
Flintlastic@ GTS-FR CoolStarT"
ASTM D6164
G
II
Flintlastic@ Premium FR-P
ASTM D6164
G
II
Flintlastic@ Premium FR-P CoolStarTM
ASTM D6164
G
II
Flintlastic@ Premium GMS
ASTM D6164
G
II
Flintlastic@ Premium GMS CoolStarTM
ASTM D6164
G
II
FlintOadT"'
ASTM D6298
N/A
N/A
5. LIMITATIONS:
5.1 This Evaluation Report is not for use in HVHZ jurisdictions.
5.2 Refer to a current Roofing Materials Directory for fire ratings of this product.
5.3 For steel deck installations, foam plastic insulation shall be separated from the building interior
in accordance with FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply.
5.4 Unless otherwise noted in Appendix 1, roof decking and its attachment shall be specified and
installed to meet project design criteria to the satisfaction of the AHJ.
5.5 For recover installations, the existing roof shall be examined in accordance with FBC 1510.
.5:�? 6For mechanically attached insulation or membrane or strip -bonded insulation, the maximum
design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure
determined in accordance with FBC Chapter 16. Zones 2 and 3 shall employ an attachment
density designed by a qualified design professional to resist the elevated pressure criteria.
Commonly used methods are RAS 117 and FM LPDS 1-29. Assemblies marked with an
asterisk* carry the limitations set forth in Section 2.2.1.5.1(a) of FM LPDS 1-29 for Zone 2/3
enhancements.
5.7 For fully -adhered insulation, the maximum design pressure for the selected assembly shall
meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No
rational analysis is permitted for these systems
Exterior Research and Design, LLC.
Certificate of Authorization #9503
Evaluation Report 3520.03.04-118
FL2533-R8
Revision 8: 08/23/2012
Page 4 of 5
1
(5. S-) For mechanically attached insulation or membrane over existing roof decks, fasteners. shall.:be
tested. -in- t_he existin_g_deck =fogy --withdrawal -resistance., A qualified design professional shall
review the data for comparison to the minimum requirements for the system. Testing and
analysis shall be in accordance with TAS 105 or ANSI/SPRI FX-1.
5.9 For bonded insulation or membrane over existing substrates in a re -roof (tear off) or recover
installation, the existing deck or existing roof surface shall be examined for compatibility with
the adhesive to be installed. If any surface conditions exist that bring system performance into
question, field uplift testing in accordance with ASTM E907, FM LPDS 1-52, ANSI/SPRI IA-1 or
TAS 124 shall be conducted on mock-ups of the proposed new roof assembly.
5.10 For bonded insulation or membrane over existing substrates in a recover installation, the
existing roof system shall be capable of resisting project design pressures on its own merit to
the satisfaction of the AHJ, as documented through field uplift testing in accordance with ASTM
E907, FM LPDS 1-52 or TAS 124.
5.11 Metal edge attachment (except gutters), shall be designed and installed for wind loads in
accordance with FBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1
or RAS 111, except the basic wind speed shall be determined from FBC Figure 1609.
5.12 All products in the roof assembly shall have quality assurance audit in accordance with the FBC
and F.A.C. Rule 9N-3.
6. INSTALLATION:
6.1 Flintlastic@ Modified Bitumen roof systems shall be installed in accordance with CertainTeed
Corporation published installation instructions, subject to the Limitations / Conditions of Use
herein.
6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. "MDP"
= Maximum Design Pressure is the result of testing for wind load resistance based on allowable
wind loads. Refer to FBC 1609.1.5 for determination of design wind loads.
7. BUILDING PERMIT REQUIREMENTS:,
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the
installation of this product.
S. MANUFACTURING PLANTS:
Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 914-3 QA requirements.
9. QUALITY ASSURANCE ENTITY:
UL, LLC. - QUA9625; (414) 248-6409, karen.buchmann@us.ul.com
- THE 43-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT -
Exterior Research and Design, LLC. Evaluation Report 3520.03.04-R8
Certificate of Authorization #9503 FL2533-R8
Revision 8: 08/23/2012
Page 5 of 5
APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE
Table Deck Application Type
Description
y
1
Page
1A
Wood
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
5-6
1B
Wood
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
7
1C
Wood
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
7
1D
Wood
New, Reroof (Tear -Off) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
8-9
' 1E-1
WSod
New, Reroof (Tear -Off)
E
Non -Insulated, ,Mech. Attached Base Sheet, Bonded Roof Cover
10-12
1E-2
Wood
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
13-14 r'
1F
Wood
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
14
2A
Steel or Conc.
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
15-16
2B
Steel or Conc.
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
17-19
2C
Steel or Conc.
New, Reroof (Tear -Off) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
20-21
3A
Concrete
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
22-25
3B
Concrete
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
26
4A
LWIC
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
27-28
4B
LWIC
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
29
4C
LWIC
New, Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
30-33
5A
CWF
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
34
5B
CWF
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
34
5C
CWF
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
35
5D
CWF
New, Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
35
6A
Gypsum
Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
36-37
6B
Gypsum
Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
38
6C
Gypsum
Reroof (Tear -Off)
C
Mech. Attached Insulation, Bonded Roof Cover
38
6D
Gypsum
Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
39
7A
Various
Recover
A-1
Bonded Insulation, Bonded Roof Cover
40-42
�\ 7B
Various
Recover
F
Non -Insulated, Bonded Roof Cover
43
Exterior Research and Design, LLC. d/b/a TrinitylERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 3520.03.04-R8 for FL2533-RB
Revision 8: 08/23/2012
Appendix 1, Page 1 of 43
The following notes apply to the systems outlined herein:
1. Roof decks shall be in accordance with FBC requirements to the satisfaction of the AH]. Wind load resistance of the roof deck shall be documented through proper codified
and/or FBC Approval documentation.
2. Unless otherwise noted, fasteners and stress plates for insulation attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements:
➢ Wood Deck: OMG #14 Roofgrip with Flat Bottom Plate (Accutrac), OMG HD with OMG 3 in. Galvalume Steel Plate, Dekfast #14 with Hex Plate or 3" Round
Insulation Plate, Trufast HD with Trufast 3" Metal Insulation Plates or FlintFast #14 Fastener with FlintFast 3" Insulation Plates. Minimum 0.75-inch
plywood penetration or minimum 1-inch wood plank embedment.
➢ Steel Deck: OMG #12 or #14 Roofgrip with Recessed or Flat Bottom Plate (Accutrac), OMG #12 Standard or HD with OMG 3 in. Galvalume Steel Plate, Dekfast
#12 or #14 with Hex Plate or 3" Round Insulation Plate, Trufast DP or HD with Trufast 3" Metal Insulation Plates or FlintFast #12 or #14 Fastener
with FlintFast 3" Insulation Plates. Minimum 0.75-inch steel penetration and engage the top flute of the steel deck. (D
➢ Concrete Deck: OMG #14 Roofgrip with Recessed or Flat Bottom Plate (Accutrac), OMG HD or CD-10 with OMG 3 in. Galvalume Steel Plate, Dekfast #14 or
DekSpike with Hex Plate or 3" Round Insulation Plate, Trufast HD or CF with Trufast 3" Metal Insulation Plates or FlintFast #14 Fastener with
FlintFast 3" Insulation Plates. Minimum 1-inch embedment. Fasteners installed with a pilot hole in accordance with the fastener manufacturer's
published installation instructions.
3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, DensDeck, DensDeck Prime, DensDeck
DuraGuard, SECUROCK Gypsum -Fiber Roof Board or SECUROCK Glass -Mat Roof Board that meets the QA requirements of F.A.C. Rule 9N-3 and is documented as meeting
FBC 1505.1 and, for foam plastic, FBC 2603.4.1 or 2603.8, when installed with the roof cover.
4. Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D (mechanically attached base sheet,
bonded roof cover), whereby the base sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal
or greater configuration to the steel and concrete deck listings.
5. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in
the manufacturer's published instructions.
➢ Hot asphalt (HA): Full coverage at 25-30 Ibs/square
➢ Ashland Pliodeck (A-PD): Continuous 0.75 inch wide ribbons, 12-inch o.c. Ribbons of subsequent layers shall be perpendicular to
those in the layer below.
➢ Dow Insta-Stik (D-IS): Continuous 0.75 to 1 inch wide ribbons, 12-inch o.c.
➢ Dow Spray-N-Grip (D-SG): Full coverage
➢ Millennium Pourable Foam Insulation Adhesive (M-PFIA): Continuous 0.5 to 0.75-inch wide ribbons, 12-inch o.c.
➢ Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c.
➢ Millennium PG-1 Pump Grade Adhesive (M-PG1): Continuous 0.5 to 0.75-inch wide ribbons, 12-inch o.c.
➢ OMG OlyBond 500 or OlyBond Green (OB500): Continuous 0.75-inch wide ribbons, 12-inch o.c. (PaceCart or SpotShot)
➢ 3M CR-20: Continuous 2.5 to 3-inch wide ribbons, 12-inch o.c. (Note: TITESET may be used where CR-20 is
referenced).
➢ Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon -applied adhesive, adhesive ribbons shall be staggered from layer -to -layer a
distance of one-half the ribbon spacing.
➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing.
Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report 3520.03.04-118 for FL2533-118
Certificate of Authorization #9503 Revision 8: 08/23/2012
Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 2 of 43
6. Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be
substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to 'increase' the MDP listings in the tables; rather if MDP
listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may be used as a drop -in for the equivalent thicker
material listed in the table:
➢ Ashland Pliodeck (A-PD) @ 12-inch o.c. MDP
-105.0 psf
(Min. 1.0-inch thick)
➢ Ashland Pliodeck (A-PD) @ 6-inch o.c. MDP
-277.5 psf
(Min. 1.0-inch thick)
➢ Dow Insta-Stik (D-IS): MDP
-120.0 psf
(Min. 1.0-inch thick)
➢ Millennium One Step Foamable Adhesive (M-OSFA): MDP
-157.5 psf
(Min. 1.0-inch thick)
➢ Millennium PG-1 Pump Grade Adhesive (M-PG1): MDP
-157.5 psf
(Min. 1.0-inch thick)
➢ OMG OlyBond 500 (OB500): MDP
-45.0 psf
(Min. 0.5-inch thick Multi -Max FA3)
➢ OMG OlyBond 500 (OB500): MDP
-187.5 psf
(Min. 0.5-inch thick ISO 95+ GL)
➢ OMG OlyBond 500 (OB500): MDP
-315.0 psf
(Min. 0.5-inch thick ENRGY 3)
➢ OMG OlyBond 500 (OB500): MDP
-487.5 psf
(Min. 0.5-inch thick ACFoam II)
➢ 3M CR-20: MDP
-117.5 psf
(Min. 1.0-inch thick)
7. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft.
8. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design
pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the
elevated pressure criteria. Commonly used methods are RAS 117 and FM LPDS 1-29. Assemblies marked with an asterisk* carry the limitations set forth in Section
2.2.1.5.1(a) of FM LPDS 1-29 for Zone 2/3 enhancements.
9. For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC
Chapter 16, and no rational analysis is permitted.
10. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall
review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105 or ANSI/SPRI FX-1.
11. For existing substrates in a bonded recover or re -roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance
with the selected adhesive, and the existing roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the AHJ, as
documented through field uplift testing in accordance with ASTM E907, FM LPDS 1-52, ANSI/SPRI IA-1 or TAS 124.
12. For Recover Applications using System Type D, the insulation is optional; however, the existing roof system shall be suitable for a recover application.
13. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications.
CertainTeed Flintlastic@ Modified Bitumen Components & Application Methods
Reference
Layer
Material
Application
BP -AA
Base
Glasbase; All Weather/Empire Base; Flexiglas Base; Flintlastic Base 20
(Base and Ply sheets, Asphalt
Hot asphalt at 20-40 Ibs/square
Applied)
ply
Flintglas Ply Sheet Type IV; Flintglas Premium Ply Sheet Type VI
BP-AA2
Base
Yosemite Venting Base
Hot asphalt in 24-inch diameter spots in
(Base, Spot -Asphalt -Applied)
30-inch grid pattern
BP-AA3
Hot asphalt in 9-inch diameter spots in
(Base, Spot -Asphalt -Applied)
Base
I
Yosemite Venting Base
I
grid pattern noted herein.
Exterior Research and Design, LLC. d/b/a TrinftylERD Evaluation Report 3520.03.04-R8 for FL2533-118
Certificate of Authorization #9503 Revision 8: 08/23/2012
Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 3 of 43
CertainTeed Flintlastic® Modified Bitumen Components & Application Methods (continued)
Reference
Layer
Material
Application
BP-AA4
(Base, Strip -Asphalt -Applied)
Base
Yosemite Venting Base
Hot asphalt in 9-inch wide ribbons spaced
as noted herein.
BP-CA2
Base/Ply
Glasbase; All Weather/Empire Base; Flexiglas Base; Flintlastic Base 20
Henry #903 Adhesive at 1.5 gal/square
BP CA3
Base/Ply
Glasbase; All Weather/Empire Base; Plexiglas Base; Flintlastic Base 20
Millennium Hurricane Force MembraneAdhesive, beads spaced 6-Inch o.c.
Base
Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base
Ply
Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base
SBS-AA
(SBS, Asphalt -Applied)
Hot asphalt at 20-40 Ibs/square
Cap
Flintlastic Cap 30; Flintlastic Cap 30 CoolStar; Flintlastic FR Cap 30; Flintlastic FR Cap 30 CoolStar; Flintlastic FR-
P; Flintlastic FR-P CoolStar; Flintlastic Premium FR-P; Flintlastic Premium FR-P CoolStar; Flintlastic GMS;
Flintlastic GMS CoolStar; Flintlastic Premium GMS; Flintlastic Premium GMS CoolStar
Base
Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base
Ply
Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base
SBS-CA1
(SBS, Cold -Applied)
Karnak No. 81 at 1.5 gal/square
Cap
Flintlastic Cap 30; Flintlastic Cap 30 CoolStar; Flintlastic FR Cap 30; Flintlastic FR Cap 30 CoolStar; Flintlastic FR-
P; Flintlastic FR-P CoolStar; Flintlastic Premium FR-P; Flintlastic Premium FR-P CoolStar; Flintlastic GMS;
Flintlastic GMS CoolStar; Flintlastic Premium GMS; Flintlastic Premium GMS CoolStar
Base
Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base
Ply
Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base
SBS-CA2
(SBS, Cold -Applied)
Henry #903 Adhesive at 1.5 gal/square.
Cap
Flintlastic Cap 30; Flintlastic Cap 30 CoolStar; Flintlastic FR Cap 30; Flintlastic FR Cap 30 CoolStar; Flintlastic FR-
P; Flintlastic FR-P CoolStar; Flintlastic Premium FR-P; Flintlastic Premium FR-P CoolStar; Flintlastic GMS;
Flintlastic GMS CoolStar; Flintlastic Premium GMS; Flintlastic Premium GMS CoolStar
Base
Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base
Ply
Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base
SBS-CA3
(SBS, Cold -Applied)
Millennium Hurricane Force Membrane
Adhesive, beads spaced 6-Inch o.c.
Cap
Flintlastic Cap 30; Flintlastic Cap 30 CoolStar; Flintlastic FR Cap 30; Flintlastic FR Cap 30 CoolStar; Flintlastic FR-
P; Flintlastic FR-P CoolStar; Flintlastic Premium FR-P; Flintlastic Premium FR-P CoolStar; Flintlastic GMS;
Flintlastic GMS CoolStar; Flintlastic Premium GMS; Flintlastic Premium GMS CoolStar
Base
Flintlastic Base 20 T; Flintlastic FR Base 20 T
Ply
Flintlastic Base 20 T; Flintlastic FR Base 20 T
SBS-TA
(SBS, Torch -Applied)
Torch -Applied
Ca
Flintlastic FR Cap 30 T; Flintlastic FR Cap 30 T CoolStar; Flintlastic GTS; Flintlastic GTS CoolStar; Flintlastic GTS-
FR; Flintlastic GTS-FR CoolStar; FlintClad
APP-TA
(APP, Torch -Applied)
Base
Flintlastic APP Base T; Flintlastic STA; Flintlastic STA Plus
Torch -Applied
Cap
Flintlastic STA; Flintlastic STA Plus; Flintlastic GTA; Flintlastic GTA CoolStar; Flintlastic GTA-FR; Flintlastic GTA-FR
CoolStar
SBS-SA-H
(SBS, Self -Adhering, Hybrid
Base/Ply
Black Diamond Base Sheet; Flintlastic Ultra Glass SA
Self -Adhering
Systems)
SBS-SA
(SBS, Self -Adhering)
Base
Flintlastic SA PlyBase; Flintlastic SA Mid Ply
Self -Adhering
Ply
Flintlastic SA PlyBase; Flintlastic SA Mid Ply
Cap
I Flintlastic SA Cap; Flintlastic SA Cap CoolStar; Flintlastic SA Cap FR; Flintlastic SA Cap FR CoolStar
14. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609.1.5 for determination
of design wind loads.
Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report 3520.03.04-R8 for FL2533-R8
Certificate of Authorization #9503 Revision 8: 08/23/2012
Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 4 of 43
IFRINOF Y E RID
TABLE 115-1: WOOD DECKS - NEW CONSTRUCTION or REROOF (Tear -Off)
V LH:'
System
Deck
Base Sheet
Roof Cover
No.
(See Note 1)
MDP (psf)
Base
Fasteners
Attach
Ply
Cap
1w-'54
wMin-ol,.T/,32-in�hithic-k4exteriorwoo
grade Dlywood attached per
'Co
Glasbase; Flexiglas; FlIntfastic
*13asV1d,wAll 'Wd-afh"r
_Emplre,Base; Poly.SMS-Base;_.§j'_
Simplex MAXX Cap_
ncho k6
Zr .,I IapjpLnd --Inchoo C-0_.
_(ntw .�kqually spaced , "st ggeredc�qt;r
(Optional); BP_
L4,
AA, SBgt-zAA, —
-SBS--AA, SBSXt 4
-Z&orA. P.P.PTAss
.. 0'
e.
.ode-
Yosemite-
rows
APP4A-
Min. 15/32-Inch thick exterior
6-Inch o.c. at 2-inch lap and 6-inch o.c.
(Optional)
W-55
grade plywood attached per
Flintlastic APP Base T
Simplex MAXX Cap
In two, equally spaced, staggered center
APP-TA
APP-TA
-90.0
Code.
rows
Min. 19/32-inch plywood at
Glasbase; Flexiglas; Flintlastic
Base 20; Poly SMS Base;
32 ga., 1-5/8-inch
5/8-Inch dla.
4-inch o.c. at 3-inch lap and 4-Inch o.c.
BP-AASBS-
SBS-AA, SBS-
W-56
max 24-inch spans attach 6-
Ultra Poly SMS Base;
tin caps with 11 ga.
in four, equally spaced, staggered center
AA, SBS-TA or
TA or APP-TA
-105.0
inch o.c. using #8 wood screws
Yosemite
annular ring shank nails
rows
APP-TA
Min. 15/32-inch thick exterior
Glasbase; Flexiglas; Flintlastic
c
6-inch o.c. at 2-inch lap and 6-inch o.c.
(Optional) BP -
W-57
grade plywood attached per
Base 20; All Weather/
Simplex MAXX Cap
in three, equally spaced, staggered
AA, SBS-AA,
SBS-AA, SBS-
-105.0
Code.
Empire Base; Poly SMS Base,
center rows
SBS-TA or
TA or APP-TA
Yosemite
APP-TA
Min, 15/32-Inch thick exterior
6-inch o.c. at 2-inch lap and 6-inch o.c.
(Optional)
W-58
grade plywood attached per
Flintlastic APP Base T
Simplex MAXX Cap
I
In three, equally spaced, staggered
I
APP-TA
APP-TA
105.0
I
Code.
center rows
Exterior Research and Design, LLC. d/b/a Trinity[ERD Evaluation Report 3520.03.04-R8 for FL2533-R8
Certificate of Authorization #9503 Revision 8: 08/23/2012
Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 12 of 43
RJ y
M I A M 1•DADE
BUILDING CODE COMPLIANCE OFFICE (BCCO)
PRODUCT CONTROL DIVISION
NOTICE OF ACCEPTANCE (NOA)
Polyglass USA, Inc.
150 Lyon Drive
Fernley, NV 69408
MIAMI-DADE COUNTY, FLORIDA
METRO-DADE FLAGLER BUILDING
140 WEST FLAGLER STREET, SUITE•1603
MIAMI, FLORIDA. 33130-1563
(305) 375-2901 FAX (305) 375-2908
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed by Miami -Dade County Product Control
Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County
and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration *date stated below. The Miami -Dade County Product
Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County)
reserve the right to have this product or material tested forquality assurance purposes. If this product or
material fails to perform -in the accepted manner, the manufacturer will incur the expense of such testing
and the AHJ may immediately revoke, modify, or suspend the use of such product or material within
.their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade
County Product Control Division that this product or material fails to meet the requirements of the
applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code and the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION Polyglass Seif-Adhe��laoof System over Wood Decks 4
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state
and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted
herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has
been no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or
change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an
endorsement of any product, for sales, advertising or any other purposes shall automatically terminate
this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of
NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed, then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No. 07-0822.10 and consists of pages 1 through 20.
The submitted documentation was'reviewed by Jorge L. Acebo,
NOA No.: 08-0226.06
Mw�a•oaoscouHrr
Expiration Dater 10/11/12
•. Approval Date: 01/28/09
Page 1 of 20
ROOFING ASSEMBLY APPROVAL
Category:
Roofing
Sub -Category:
Modified Bitumen
Materials
SBS/APP/TPO
Deck Type:
Wood
Maximum Design Pressure
-112.5 psf
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test
Product Dimensions Specification
Elastobase 65' 2" x 3' 3-3/8" ASTM D 4601
Elastobase P 5' 2" x 3' 3-3/8" ASTM D6164
Elastoflex SA V 32' 6" x 3' 3-3/8" ASTM D 6163
Vent
Elastoflex SA V 32' 6" x 3' 3-3/8" ASTM D 6163
FR
Elastoflex SA V 32' 6" x 3' 33/8" ASTM D 6163
Elastoflex SA P 32' 6" x 3' 3-3/8" ASTM D 6164
FR
Elastoflex SA P 32' 6" x 3' 3-3/8" ASTM D 6164
Polyflex SA P 32' 6" x 3' 33/8" ASTM D 6222
Polyflex SA P FR 32' 6" x 3' 33/8" ASTM D .6222
PoIyfresko SBS 32' 6" x 3' 3-3/8" . ASTM D 6164
SAP
PoIyfresko SBS 32' 6" x 3' 3-3/8" ASTM D 6164
SAP FR
Polyfresko APP 32' 6" xY 33/8" ASTM D 6222
SAP
M AMI•UADE COUNTY
Product
Description
SBS modified asphalt coated fiberglass
reinforced base sheet.
SBS modified asphalt coated polyester
reinforced base sheet.
Partially self -adhered, fiberglass reinforced,
SBS modified bitumen membrane with a self -
adhering back face and a smooth top surface.
Self -adhered, fiberglass reinforced, SBS
modified bitumen membrane with a self -
adhering back face and a smooth top surface.
Self -adhered, fiberglass reinforced, SBS
modified bitumen membrane with a self -
adhering back face and a smooth top surface.
Self -adhered, polyester reinforced, SBS
modified bitumen membrane with a self -
adhering back face and a granule top surface.
Self -adhered, fiberglass reinforced, SBS
modified bitumen membrane with a self -
adhering back face and a granule top surface.
Self -adhered, polyester reinforced, APP
modified bitumen membrane with a self -
adhering back face and a granule top surface.
Self -adhered, polyester reinforced, APP
modified bitumen membrane with a self -
adhering back face and a granule top surface.
Self -adhered, fiberglass reinforced, SBS
modified bitumen membrane with a self -
adhering back face. and a granule top surface.
Self -adhered, polyester reinforced, SBS
modified bitumen membrane with a self -
adhering back face and a granule top surface.
Self -adhered, polyester reinforced, APP
modified bitumen membrane with a self -
adhering back face and a granule top surface.
NOA No.: 08-0226.06
Expiration Date: 10/11/12
Approval Date: 01/28/09
Page 2 of 20
Product
Polyfresko APP
SAP FR
PolyKool
PolyBianko
Cold Process
Adhesive
PG100 Asphalt
Primer
PG350 ModBit
Adhesive
PG400 Plastic
Roof Cement
PG425 Wet/Dry
Roof Cement
PG450 Flashing
Cement
PG500 MB
Flashing Cement
Polyplus 35
Premium Mod Bit
Adhesive
Polyplus 45
Premium Flashing
Cement
Polyplus 50
Premium MB
Flashing Cement
Polyplus 55
Premium Modified
Flashing Cement
Test
Dimensions Specification
32' 6" x 3' 3 3/e" ASTM D 6222
32' 10" x 3' 33/g" ASTM D6222
Type I
32' 10" x 3' 33/8" ASTM D6222
Type
1, 3, 5, 50, 55 gal.
ortube
I, 3, 5, 50, 55 gal,
tube or 17 oz.
spray can
1, 3, 5, 50, 55 gal.
or tube
1, 3, 5, 50, 55 gal.
or tube
1, 3, 5, 50, 55 gal.
or tube
I, 3, 5, 50, 55 gal.
or tube
1, 3, 5, 50, 55 gal.
or tube
1, 3, 5, 50, 55 gal.
or tube
1, 3, 5, 50, 55 gal.
or tube
ASTM D3019
Type III
ASTM D41
Product
Description
Self -adhered, polyester reinforced, APP
modified bitumen membrane with a self -
adhering back face and a granule top surface.
Self -adhered, polyester reinforced, APP
modified bitumen membrane with a self -
adhering back face and a white film laminate on
the top surface.
Self -adhered, polyester reinforced, APP
modified bitumen membrane with a self -
adhering back face -and a white film Iaminate on
the top surface.
A fibered cold process adhesive for use with
roll or BUR roofing.
A penetrating solution of solvent and a blend of
selected asphalts used to promote adhesion.
ASTM D3019
A fibered rubberized adhesive designed for use
Type III
with modified bitumen membranes.
ASTM D4586
A thick, fibered, rubberized flashing cement for
ASTM D3409
use in dry or damp conditions.
ASTM D4586
A thick, fibered, rubberized flashing cement for
ASTM D3409
use in dry or damp conditions.
ASTM D4586
A thick, fibered, rubberized flashing cement.
ASTM D4586
A thick, fibered, rubberized flashing cement for
use with modified bitumen membranes.
ASTM D3019
A fibered rubberized adhesive designed for use
Type III
with modified bitumen membranes.
ASTM D4586 A thick, fibered, rubberized flashing cement.
1, 3, 5, 50, 55 gal. ASTM D4586 A thick, fibered, rubberized flashing cement for
or tube use with modified bitumen membranes.
1, 3, 5, 50, 55 gal. ASTM D4586 A mastic compound for use as a roof flashing
or tube adhesive.
NOA No.: 08-0226.06
Expiration Date: 10/11/12
MiartuaAflE co nrnr Approval Date: 01/28/09
Page 3 of 20
APPROVED INSULATIONS:
Product Name
Polytherm, POLYTHERM A 1
Polytherm Composite
ACFoam II
ACFoam III
High Density Wood Fiberboard
Perlite Insulation
Type X Gypsum
Dens -Deck, Dens -Deck Prime
H-Shield
H-Shield CG
ENRGY-3, JM ISO 3
Fesco Board
Multi -Max, Multi -Max FA
Securock
APPROVED FASTENERS:
Fastener Product
Number Name
1. Dekfast Fasteners #12,
#14 & #I5
2. Dekfast Hex Plate
TABLE 2
Product Description
Manufacturer
(With Current NOA)
Polyisocyanurate foam insulation
Polyglass USA, Inc.
Polyisocyanurate/perlite composite
Polyglass USA, Inc.
insulation.
Polyisocyanurate foam insulation
Atlas Energy Products
Polyisocyanurate foam insulation
Atlas Energy Products
Wood fiber insulation board
Generic
Perlite insulation board
Generic
Fire resistant rated gypsum.
Generic
Gypsum insulation board
Georgia-Pacific
Polyisocyanurate foam insulation
Hunter Panels, LLC
Polyisocyanurate/perlite composite
Hunter Panels, LLC
insulation
Polyisocyanurate foam insulation
Johns Manville Corp.
Expanded mineral fiber
Johns Manville Corp.
Polyisocyanurate foam insulation
RMax, Inc.
Fiber reinforced coverboard
USG
TABLE 3
Product
Description
Insulation fastener for
wood, steel and concrete
decks
Galvalume hex stress plate.
3.
Dekfast Lock Plate
Polypropylene locking
plate.
4.
#12 & #14 Roofgrip
Insulation and membrane
fastener
5.
Metal Plate
Galvalume AZ50 stress
plate
6.
Plastic Plate
Polyethylene stressiplate
7.
Insul-Fixx HD Fastener
Insulation fastener for steel
and wood decks
Manufacturer
Dimensions (With Current NOA)
SFS Intec
2 7/$" x
3 '/4"
3" x 3 1/"
Various
3" square
3.2" round
Various
SFS Intec
SFS Intec
OMG
OMG
OMG
SFS Intec
NOA No.: 08-0226.06
Expiration Date: 10/11/12
Approval Date: 01/28/09
Page 4 of 20
0
APPROVED FASTENERS:
TABLE 3
Fastener Product Product
Manufacturer
Number Name Description
Dimensions (With Current NOA)
8. Insul-Fixx S
Galvalume AZ55 stress
3" round SFS Intec
plate
9. Insul-Fixx P
Polyethylene stress plate 3" round SFS Inter
10. Tru-Fast HD
Insulation fastener for steel The Tru-Fast Corp.
and wood decks
11. Tru-Fast Plates Galvalume AZ55 steel plate 3" round The Tru-Fast Corp.
12. Tru-Fast Plates Polyethylene plastic plate 3" round The Tru-Fast Corp.
APPROVED SURFACING:
TABLE 4
Product
Name
Product
Description
Application Specification Manufacturer
Rate
PG200 Non-Fibered
A non fibered asphaltic coating
1'/2-2 gat/sq TAS 140 Polyglass
Roof Coating
used to add life and rejuvenate
USA, Inc.
existing BUR roofing substrates.
PG300 Fibered Roof
An asphalt cutback fibered roof
11/2-2 gal/sq ASTM D4479 Polyglass
Coating
coating. May be applied by brush
USA, Inc.
or spray equipment to rejuvenate
aged BUR
PG600 Non-Fibered
Non-fibered aluminum roof
'/2-1 gaUsq ASTM D2824 Polyglass
Aluminum Roof
coating.
Type I USA, Inc.
Coating
PG650 Fibered
Fibered aluminum roof coating.
1'/2-2 gaUsq ASTM D2824 Polyglass
Aluminum Roof
Type III USA, Inc.
Coating
PG700 White Reflective
A premium white elastomerie
1-I'/2 gal/sq ASTM D6083 Polyglass
Roof Coating
acrylic based roof coating (water-
USA, Inc.
based). A polyester fabric may be
used for reinforcement with this
coating. .
PG800 Non-Fibered
An asphalt base, un-fibered clay
3 gaUsq in ASTM D1227 Polyglass
Asphalt Emulsion Roof
emulsion
two coats USA, Inc.
Coating
PG850 Fibered Asphalt
An asphalt base, fibered clay
3 gaUsq in ASTM D1227 Polyglass
Emulsion Roof Coating
emulsion
two coats USA, Inc,
Polyplus 65 Premium
Fibered aluminum roof coating.
1'/2-2 gal/sq ASTM D2824 Polyglass
Fibered Aluminum Roof
Type III USA, Inc.
Coating
NOA No.: 08-0226.06
u1MIOWEcouNTY Expiration Date: 10/11/12
.... , Approval Date: 01/28/09
Page 5 of 20
L
APPROVED SURFACING:
TABLE 4
Product
Name
Product
Description
Application Specification
Rate
Manufacturer
Polyplus 60 Premium
Non-fibered aluminum roof
%-1 gal/sq ASTM D2824
Polyglass
Non-Fibered Aluminum
coating.
Type I
USA, Inc.
Roof Coating
Polybrite 70 White
A premium white. elastomeric
1-1'/z gal/sq ASTM D6083
Polyglass
Elastomeric Roof
acrylic based roof coating (water-
USA, Inc.
Coating
based). A polyester fabric may be
used for reinforcement with this
coating.
Mule -Hide I I I Non-
Anon-fibrated asphaltic coating
1%-2 gal/sq TAS 140
Mule -Hide
Fibrated Roof Coating
used to add life and rejuvenate
Products
existing BUR roofing substrates.
Co., Inc.
Mule -Hide 102.Fibmted
An asphalt cutback fibered roof
1 %Z-2 ga1/sq ASTM D4479
Mule -Hide
Roof Coating
coating. May be applied by brush
Products
or spray equipment to rejuvenate
Co., Inc.
aged BUR
Mule -Hide 416 Standard
Non-fibrated aluminum roof
%z-1 gal/sq ASTM D2824
Mule -Hide
Non-Fibrated Aluminum
coating.
Type I
Products
Roof Coating
Co,, Inc.
Mule -Hide 406 Standard
Fibrated aluminum roof coating.
1 %2-2 gal/sq ASTM D2824
Mule -Hide
Fibrated Aluminum
Type III
Products
Roof Coating
Co., Inc.
Mule -Hide 401
Fibrated aluminum roof coating.
1%-2 gal/sq ASTM D2824
Mule -Hide
Premium Fibrated
Type III
Products
Aluminum Roof
Co., Inc.
Coating
Mule -Hide 410
Non-fibrated aluminum roof
%4 gal/sq ASTM D2824
Mule -Hide
Premium Non-Fibrated
coating.
Type I
Products
Aluminum Roof
Co., Inc.
Coating
Mule -Hide 311
An;asphalt base, un-fibered clay
3 gal/sq in . ASTM D1227
Mule -Hide
Emulsion Non-Fibrated
emulsion
two coats
Products
Co., Inc.
Mule -Hide 301
An asphalt base, fibered clay
3 gal/sq in ASTM D1227
Mule -Hide
Emulsion Fibrated
emulsion
two coats
Products
Co., Inc.
Gravel
To be installed in a flood coat of
400 lbs/sq N/A
Generic
approved asphalt at 60 lbs/sq
Slag
To be installed in a flood coat of
300 lbs/sq N/A
Generic
approved asphalt at 60 Ibs/sq
I
NOA No.: 08-0226.06
Expiration Date: 10/11/12
Approval Date: 01/28/09
Page 6 of 20
EVIDENCE SUBMITTED:
Test Agency
Test Name/Report
Report No.
Factory Mutual Research
4470
J.I.3001334
Corporation
4470
J.I.3000857
4470
J.I.3004091
Underwriters Laboratory
TAS 114
OONK20869
Trinity ERD
TAS 114
11751.05.03
TAS 114
11758,08.03
TAS 114
P1738.02.07
TAS 117(B)-ASTM D903
020841.06.04
TAS 114
11757.12.00-1
TAS 114
11757,04.01-1
TAS 114-J
P9260.03.08
TAS 114-J
P7860SC.11:08
TAS 117(B)-ASTM D6862
C8500SC.11.07
ASTM D6164 / ASTM D6222
P 10490.08.08
ASTM D6164 / ASTM D6222
P10490.10.08-R1
ASTM D6222
P7400.03.08-R1
TAS 114(D) — ASTM D 1876
P 10070.10.08
ASTM D6222
P10490.10.08-2
PRI Asphalt Technologies
ASTM D6222
PUSA-061-02-02
ASTM D6222
PUSA-062-02-02
ASTM D6163.
PUSA-064-02-02
Date
02.15.00
01.12.00
0I.12:00
06.08:00
05.30.03
08.11.03
02.05.07
06.02.04
12.01.00
04.27.01
03.21.08
I 1.30.07
11.30.07
08.13.08
10.03.08
04.04.08
10.09.08
10.30.08
01.28.08
12.04.08
02.27.08
NOA No.: 08-0226.06
Expiration Date: 10/11/12
Approval Date: 01/28/09
Page 7 of 20
APPROVED ASSEMBLIES:
Deck Type 1I: Wood, Insulated
Deck Description: 19/32" or greater plywood or wood plank, fastened with 8d common nails at 4" o.c.
or #8 wood screws at 6" o.c.
System Type A(1): All insulation layers are adhered to a mechanically attached anchor sheet.
Membrane is subsequently adhered to insulation.
All General and System limitations apply.
Anchor Sheet: .One ply of Elastobase or Elastobase P fastened to the deck as described below:
Fastening: Attach base sheet using Buildex Roofgrip Fasteners and Flat Bottom Plates spaced
12" o.c. in a 4" lap and 12"' o.c. in two equally spaced staggered rows in the center
of the sheet.
One or more of the following
Base Insulation Layer (Optional)
Any approved Polyisocyanurate
Minimum 1" thick
Top Insulation Layer
Dens Deck, Dens Deck Prime, Securock
Minimum'/a" thick
Insulation Fasteners Fastener
(Table 3) Density/ft2
N/A N/A
Insulation Fasteners Fastener
(Table 3) Density/fe
NIA N/A
Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt
within the EVT range and at a rate of 20-40 lbs/100 W. Please refer to Roofing Application
Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used
only as base layers with a second layers of approved top layer insulation installed -as the final
membrane substrate. Composite insulation panels may be used as a top layer placed with the
polyisocyanurate side facing down.
Base Sheet: One or more plies of Eiastoflex SA V or Elastoflex SA V FR self -adhered
Membrane: One ply of Polyfresko SBS SAP, Polyfresko..SBS SAP FR, Polyfresko APP SAP,
Polyfresko APP SAP FR, Elastoflex SA'P, Elastoflex SA P FR, Polyflex SA P,
PolyBianko, PolyKool or Polyflex SA P FR self adhered.
Surfacing: (Optional) Install one of the approved surfacing products Iisted in Table 4 to
obtain desired coating or required fire classification.
Maximum Design
Pressure: -60 psf, (See general limitation V.)
NOA No.: 08-0226.06
MI,ara •Wane ouNn
Expiration Date: 10/11/12
Approval Date: 01/28/09
Page 8 of 20
�Y
Deck Type 11: Wood, Insulated
Deck Description: 19/32" or greater plywood or wood plank, fastened with 8d common nails at 4" o.c.
or #8 wood screws at 6" o.c.
System Type A(2): All insulation layers are adhered to a mechanically attached anchor sheet.
Membrane is subsequently adhered to insulation.
All General -and System Limitations apply.
Anchor Sheet: One ply of CertainTeed G1asBase, Polyglass Base, Firestone MB Base, JM
Perma-Ply #28, Tamko Glass Base or GAFGLAS #75 fastened to the deck as
described below:
Fastening: Attach base sheet using 11 ga. Annular ring shank and 1-5/8" diameter tin caps
spaced 8" o.c. in a 4" lap and 8" o.c. in three equally spaced staggered rows in
the center of the sheet.
One of more of the following:
Base Insulation Layer (Optional) Insulation Fasteners Fastener
(Table 3) Density/ft2
Any approved Polyisocyanurate
NHuimum 1" thick N/A N/A'
Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt
within the EVT range and at a rate of 20-40 lbs/100 fe. Please refer to Roofing Application
Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used
only as base layers with a second layer of approved top layer insulation installed as the final
membrane substrate. Composite insulation panels may be used as a top layer placed with the
polyisocyanurate side facing down.
Top Insulation Layer
Dens Deck, Dens Deck Prime, Securock
Minimum %11 thick
Insulation Fasteners Fastener
(Table 3) Density/fe
N/A N/A
Note: Apply top layer of insulation in a full mopping of any approved mopping asphalt within the
EVT range and at a rate of 20-401bs/100 W. Please refer to Roofing Application Standard RAS
117 for insulation attachment. Insulation listed as Base Layer only shall be used only as base
layers with a second .layer of approved top layer insulation installed as the final membrane
substrate. Composite insulation panels may be used as a top layer placed with the
polyisocyanurate side facing down.
Base Sheet: ' One or more plies of Elastoflex SA V or Elastoflex SA V FR self-
adhered
Membrane: One ply of Polyfresko SBS SAP, Polyfresko SBS SAP FR, Polyfresko APP SAP,
Polyfresko APP SAP FR, Elastoflex SA P, Elastoflex SA P FIR, Polyflex. SA-P,
PolyBianko, PolyKool or Polyflex SA P FR self adhered.
Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to
obtain desired coating or required fire classification.
Maximum Design
Pressure: -60 psf, (See general limitation #7.)
NOA No.: 08-0226.06
Expiration Date: 10/11/12
Approval Date: 01/28/09
Page 9 of 20
L-
t\ J,I
Deck Type 1I: Wood, Insulated
Deck Description: 19/s? or greater plywood or wood plank.
System Type A(3): All insulation layers are adhered to a mechanically attached anchor sheet.
Membrane is subsequently adhered to insulation.
All General and System Limitations apply.
Anchor Sheet: One ply of CertainTeed GlasBase, Polyglass Base, Elastobase, Firestone MB
Base, JM Perma-Ply #28, Tamko Glass Base or GAFGLAS #75 fastened to the
deck as described below:
Fastening #1: Attach base sheet using 11 ga. annular -ring shank and 1-5/8" diameter tin caps
spaced 8" o.c. in a 4" lap and 8" o.c. in three equally spaced staggered rows in the
center of the sheet.
Fastening #2: Attach base sheet using Buildex Roofgrip Fasteners and Flat Bottom Plates,
Dekfast #14 with Hex Plates or Tru-Fast HD with MP-3 Plates spaced 12" o.c, in a
4" Iap and 12" o.c. in two equally spaced staggered rows in the center of the sheet.
One or more of the following
Base Insulation Layer (Optional) Insulation Fasteners Fastener
(Table 3) Density/ftz
Any approved Polyisocyanurate
Minimum 1" thick N/A N/A
Note: All insulation shall be adhered to the anchor sheet in full mopping of approved` hot asphalt
within the EVT range and at a rate of 20-40 lbs/100 ff. Please refer to Roofing -Application
Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used
only as base layers with a second layer of approved top layer insulation installed as the final
membrane substrate. Composite insulation panels may be used as a top layer placed with the
polyisocyanurate side facing down.
Top Insulation Layer
Dens Deck, Dens Deck Prime, Securock
Minimum %11 thick
Insulation Fasteners Fastener
(Table 3) Density/fe
N/A N/A
Note: Apply top layer of insulation in a full mopping of any approved mopping asphalt within the
EVT range and at a rate of 20-4.0 lbs/100 fe. Please refer to Roofing Application Standard RAS
117 for insulation attachment. Insulation listed as Base Layer only shall be used only as base
layers with a second layer of approved top layer insulation installed as the final membrane
substrate. Composite insulation panels may be used as a top layer placed with the
polyisocyanurate side facing down.
Base Sheet: One or more plies of Elastoflex SA V or Elastoflex SA V FR self -adhered. '
Membrane: One ply of Polyfresko SBS SAP, Polyfresko SBS SAP FR, Polyfresko APP SAP,
Polyfresko APP SAP FR, Elastoflex SA P, Elastoflex SA P FR, Polyflex SA P,
PolyBianko, PolyKool or Polyflex SA P FR self adhered.
Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to
obtain desired coating or required fire classification.
Maximum Design
Pressure: -52.5 psf; (See general limitation #7,)
NOA No.: 08-0226.06
MIAM4DADECd N
Expiration Date: 10/11/12
. � � 1 Approval Date: 01/28/09
Page 10 of 20
Deck Type 1I: • Wood, Insulated
Deck Description: 19/32" or greater plywood or wood plank.
System Type A(4): All insulation layers are adhered to a mechanically attached anchor sheet.
Membrane is subsequently adhered to insulation.
All General and System Limitations apply.
Anchor Sheet: One ply of Elastobase or Elastobase P fastened as below:
Fastening: 12 ga. Annular ring shank nails and 1-5/8" tin -caps attached 6" o.c. in 4" lap and
6" o.c. in four equally spaced staggered rows.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/fe
ACFoam 1% ACFoam III,11 Shield, H Shield CG, Multi -Max FA3, or ENRGY-3
Minimum 1" thick N/A N/A
Insulation: Adhered with WeatherTite One -Step Foamable Adhesive applied over rows of tin -
caps in continuous rows 7" o.c.
Base Sheet: One or more plies of Elastoflex SA V or Elastoflex SA V FR self -adhered.
Membrane: One ply of Polyfresko SBS SAP, Polyfresko SBS SAP FR, Polyfresko APP SAP,
Polyfresko APP SAP FR, Elastoflex SA P, Elastoflex SA P FR, Polyflex SA P,
PolyBianko,•PolyKool or Polyflex SA P FR self adhered.
Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to
obtain desired coating or required fire classification.
Maximum Design
Pressure: -60 psf; (See general limitation V.)
NOA No.: 08-0226.06
MIAM!•DADE COUNTY
Expiration Date: 10/11/12
Approval Date: 0128/09
Page 11 of 20
Deck Type 1I: Wood, Insulated
Deck Description: f9/32" or greater plywood or wood plank; fastened with wood screws at 6" o.c.
System Type C(1): . All layers of insulation are mechanically attached to roof deck. Membrane is
subsequently adhered to.insulation.
All General and System Limitations apply.
One -or more of the following
Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/fe
ENRGY-3, H-Shield or Polytherm
Minimum 1.5" thick 1, 7 or 10 1:1.33 ft2
Note: All layers of insulation shall be mechanically attached using the fastener density listed
above. The insulation panels listed are minimum sizes and dimensions; if larger panels are used,
the number of fasteners shall be increased maintaining the same fastener density. Please refer to
Roofing Application Standard RAS 117 for insulation attachment.
Base Sheet: One or more plies. of Elastoflex SA V or Elastoflex SA V FR self -adhered.
Membrane: One ply of Polyfresko SBS SAP, Polyfresko SBS SAP FR, Polyfresko APP SAP,
Polyfresko APP SAP FR, Elastoflex SA P, Elastoflex SA P FR, Polyflex SA P,
PolyBianko, PolyKool or Polyflex SA P FR ..self adhered.
Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to
obtain desired coating or required fire classification.
Maximum Design
Pressure: -82.5 psf; (See General limitation #7.)
NOA No.: 08-0226.06
CE COUNTYExpiration Date: 10/I1/12
• • • r Approval Date: 01/28/09
Page 12 of 20
J
Deck Type 11: Wood, insulated
Deck Description: 19/32" or greater plywood or wood plank, fastened with 8d common nails at 4" o.c.
System Type C(2): All layers of insulation are mechanically attached to roof deck. Membrane is
subsequently adhered to insulation.
All General and System Limitations apply.
One or more layers of the following:
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/fe
Any approved'Polyisocyanurate
Minimum 1.5" thick N/A N/A
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density.
Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number
of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing
Application Standard RAS 117 for insulation attachment.
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft,
High Density Wood Fiber
Minimum %11 thick 1 1:1.33 W
Dens Deck
Minimum'/" thick 1 1:1.33 ft'
Note: All layers of insulation shall be mechanically attached using the fastener density listed
above. The insulation panels listed are minimum sizes and dimensions; if larger panels are used,
the number of fasteners shall be increased maintaining the same fastener density. Please refer to
Roofing Application Standard RAS 117 for insulation attachment. ,
Base Sheet: One or more plies of Elastoflex SA V or Elastoflex SA V FR self -adhered.
Membrane: One ply of Polyfresko SBS SAP, Polyfresko SBS SAP FR, Polyfresko APP SAP,
Polyfresko APP SAP FR, Elastoflex SA P, Elastoflex SA P FR, Polyflex SA P,
PolyBianko, PolyKool or Polyflex SA P FR self adhered.
Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to
obtain desired coating or required fire classification.
Maximum Design
Pressure: -67.5 psf; (See General limitation V.)
NOA No.: 08-0226.06
Expiration Date: 10/11/12
MlArtt , � ED, Approval Date: 01/28/09
Page 13 of 20
Deck Type 11: Wood, Insulated
Deck Description: 19/32" or greater plywood or wood plank.
System Type C(3): All layers of insulation'are mechanically attached to roof deck. Membrane is
subsequently adhered to insulation.
All General and System Limitations apply.
One or more of the'following
Base Insulation Layer
Any approved Polyisocyanurate
Minimum 1.5" thick
Insulation Fasteners Fastener
(Table 3) Density/fe
N/A N/A
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density.
Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number
of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing
Application Standard RAS 117 for insulation attachment. �
Top Insulation Layer
High Density Wood Fiber
Minimum %11 thick
Dens Deck
Minimum %11 thick
Insulation Fasteners Fastener
(Table 3) Density/ft2
1 ' 1:1.33 ftz
1 1:1.33 W
Note: All layers of insulation shall be mechanically attached using the fastener density listed
above. The insulation panels listed are minimum sizes and dimensions; if larger panels are used,
the number of fasteners shall be increased maintaining the same fastener density. Please refer to
Roofing Application Standard RAS 117 for insulation attachment.
Base Sheet: One or more plies of Elastoflex SA V or Elastoflex SA V FR self -adhered.
Membrane: One ply of Polyfresko SBS SAP, Polyfresko SBS SAP FR, Polyfresko APP SAP,
Polyfresko APP SAP FR, Elastoflex SA P, Elastoflex SA P FR, Polyflex SA P,
PolyBianko, PolyKool,or Polyflex SA P,FR self adhered.
Surfacing: (Optional) Install one of the approved su
obtain desired coating or required fire cl
Maximum Design
Pressure: -52.5 psf; (See General limitation V.)
i
I
products listed in Table 4 to
NOA No.: 08-0226.06
Expiration Date: 10/11/12
Approval Date: 01/28/09
Page 14 of 20
Deck Type II: Wood, Insulated
Deck Description: 19/32" or greater plywood or wood plan
or #8 wood screws at 6" o.c.
System Type D(1): All layers of insulation and base sheet,
subsequently adhered.
All General and System Limitations apply.
One or more layers of the following:
Base Insulation Layer
Any approved Polyisocyanurate
Minimum 1" thick
Top Insulation Layer (Optional)
Fesco Board
Minimum %11 thick
High Density Wood .Fiber
fastened with 8d common nails at 4" o:c.
fastened, membrane
Insulation Fasteners Fastener
(Table 3) ' . Density/ft2
N/A N/A
Insulation Fasteners Fastener
(Table 3) Density/fe
N/A N/A
Minimum V2" thick N/A N/A
Dens Deck, Dens Deck Prime, Secnrock
Minimum'/" thick i N/A N/A
Note: All insulation shall have preliminary attachment, prior to the installation of the roofing
membrane at a minimum application rate of two fasteners per board for insulation boards having
no dimension greater than 4 ft.,•and four fasteners for any insulation board having no dimension
greater than 8 ft.
Base Sheet: One or more plies of Elastobase or Elasltobase P fastened to the deck as described
below:
Fastening: Attach base sheet using Buildex Roofgrip Fasteners and Flat Bottom Plates spaced
12" o.c. in a 4" lap and 12" o.c. in two equally spaced staggered rows in the center
of the sheet.
Ply Sheet: One or more plies of Elastoflex SA V or Elastoflex SA V FR self -adhered.
Membrane: One ply of Polyfresko SBS SAP, Polyfresko SBS SAP FR, Polyfresko APP SAP,
Polyfresko APP SAP FR, Elastoflex SA P, Elastoflex SA P FR, Polyflex SA P,
PolyBianko, PolyKool or Polyflex SA P FR self adhered.
Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to
'obtain desired coating or required fire classification.
Maximum Design
Pressure: -60 psf; (See General limitation V.) i
NOA No.: 08-0226.06
Expiration Date: 10/11/12
Approval Date: 01/28/09
Page 15 of 20
Deck Type 1I: Wood, Insulated
Deck Description: 19/32" or greater plywood or wood plank)
System Type D(2): All layers of insulation and base sheet simultaneously attached, membrane
subsequently adhered..
All General and System Limitations apply.
One or more layers of the following:
Base Insulation Layer
Insulation Fasteners
Fastener
(Table 3)
Density/fe
Any approved Polyisocyanurate
Minimum 1" thick
N/A
N/A
Top Insulation Layer (Optional)
Insulation Fasteners
Fastener
(Table 3)
Density/ft�
Fesco Board
Minimum %11 thick
N/A
N/A
High Density Wood Fiber
Minimum'/" thick
N/A
N/A
Dens Deck, Dens Deck Prime, Securock
Minimum I/" thick N/A N/A
Note: All insulation shall have preliminary attachment, prior to the installation of the roofing
membrane at a minimum application rate of two fastenersiper board for insulation boards having
no dimension greater than 4 -ft., and four fasteners for any insulation hoard having no dimension
greater than 8 ft.
Base Sheet: One or more plies of Elastobase or Elastobase P fastened to the deck as described
below:
Fastening Attach base sheet using Buildex Roofgrip Fasteners and Flat Bottom Plates,
Dekfast #14 with Hex Plates or Tru-Fast with MP-3 Plates spaced 12" o.c. in a
4" lap and 12" o.c. in two equally spacedl taggered rows in the center of the sheet.
i
Ply Sheet: One or more plies of Elastoflex SA V or Elastoflex SA V FR self -adhered.
i
Membrane: One ply of Polyfresko SBS SAP, Polyfresko SBS SAP FR, Polyfresko APP SAP,
Polyfresko APP SAP FR, Elastoflex SA P, Elastoflex SA P FIR, Polyflex SA P,
PolyBianko, PolyKool or Polyflex SA P FR self adhered.
Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to
obtain desired coating or required fire classification.
Maximum Design
Pressure: -52.5 psf; (See General limitation V.) 1
i
NOA No.: 08-0226.66
Expiration Date: 10/11112
Approval Date: O1/28109
Page 16 of 20
r'
Deck Type 1: Wood, Non -Insulated
Deck Description: '19/32" or greater plywood or wood
or #8 wood screws at 6" o.c.
fastened with 8d common nails at 4" o.c.
System Type E(1): Base sheet is mechanically attached to'roof deck.
All General and System Limitations apply.
Base Sheet: One ply of Elastobase or Elastobase P fastened to the deck as described below:
Fastening: Attach base sheet using Buildex Roofgl ip Fasteners and Flat Bottom Plates spaced
12" o.c. in a 4" lap and 12" o.c. in two equally spaced staggered rows in the center
of the sheet.
Ply Sheet: One or more plies of Elastoflex SA V it
Elastoflex SA V FR self -adhered.
Membrane: One ply of Polyfresko SBS SAP, Polyfresko
SBS SAP FR, Polyfresko APP SAP,
Polyfresko APP SAP FR, Elastoflex SA
P, Elastoflex SA P FR, Polyflex SA P,
PolyBianko, PolyKool or Polyflex SA
P FR self adhered.
Surfacing: (Optional) Install one of the approved surfacing
products listed in Table 4 to
obtain desired coating or required fire classification.
Maximum Design
Pressure: -60 psf; (See General limitation V.)
Deck Type 1: Wood, Non -Insulated
Deck Description: 19/32" or greater plywood or wood plank
fastened with 8d common nails at 4" o.c.
or #8 wood screws at 6" o.c.
System Type E(2): Base sheet is mechanically attached to roof deck.
i
All General and System Limitations apply.
Base Sheet: One ply of Elastobase or Elastobase P Ld to the deck as described below:
Fastening: Attach base sheet using 11 ga. annular ling shank and 1-5/8" diameter tin caps
spaced 8" o.c. in a 4" lap and 8" o.c. to three equally spaced staggered rows in the
center of the sheet.
I
Ply Sheet: One or more plies of EIastoflex SA V or Elastoflex SA V FR self -adhered.
i
Membrane: One ply of Polyfresko SBS SAP, Polyfresko SBS SAP FR, Polyfresko APP SAP,
Polyfresko APP SAP FR, Elastoflex SA P, Elastoflex SA P FR, Polyflex SA P,
PolyBianko, PolyKool or Polyflex SA P FR self adhered.
Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to
obtain desired coating or required fire classification.
Maximum Design
Pressure: -60 psf; (See General limitation P.)
NOA No.: 08-0226.06
MIAMMADE OUNTY
Expiration Date: 10/11/12
• , •, , Approval Date: 01/28/09
Page 17 of 20
Deck Type 1:
Wood, Non -Insulated
Deck Description:
19/32" or greater plywood or wood plank.
System Type E(3):
Base sheet ig-mechanically attached to 'roof deck.
All General and System Limitations apply.
Base Sheet:
One ply of Elastobase or Elastobase P fastened to the deck as described below:
Fastening #1:
Attach base sheet using I 1 ga. annular ring shank and 1-5/8" diameter tin caps
spaced 8" o.c. in a 4" lap and 8" o.c. in ithree equally spaced staggered rows in the
center of the sheet.
Fastening #2:
Attach base sheet using Buildex Roofgrip Fasteners and Flat Bottom Plates,
Dekfast #14 with Hex Plates or Tru-Fast HD with MP-3 Plates spaced 12" o.c. in a
4" lap. and 12" o.c, in two equally spaced staggered rows in the center of the sheet.
Ply Sheet:
One or more plies of Elastoflex SA V or Elastoflex SA V FR self -adhered.
Membrane:
One ply of Polyfresko SBS SAP, Polyfresko SBS SAP FR, Polyfresko APP SAP,
Polyfresko APP SAP FR, Elastoflex SA P, Elastoflex SA P FR, Polyflex SA P,
PolyBianko, PolyKool or Polyflex SA P FR self adhered.
Surfacing:
I
(Optional) Install one of the approved surfacing products listed in Table 4 to
obtain desired coating or required fire classification.
Maximum Design
Pressure:
-52.5 psf; (See General limitation P.).
Deck Type 1:
I
Wood, Non -Insulated j
i
Deck Description:
19/32" or greater plywood or wood plank; fastened to supports spaced 24" o.c. and
to blocking members spaced 48". o.c. with. TruFast TP #1 Ox2-7/8" screws spaced
6" o.c.
System Type E(4):
Base sheet is mechanically attached to roof deck.
All General and System Limitations apply.
Base Sheet:
One ply of Elastobase or Elastobase P fastened to the deck as described below:
Fastening:
I
Attach base sheet using 12 ga. ring shank nails and tin caps spaced 4" o.c. in a 4"
lap and 4" o.c. in four equally spaced staggered rows in the center of the sheet.
I
Ply Sheet:
One or more plies of Elastoflex SA V or, Elastoflex SA V FR self -adhered.
Membrane:
One ply of Polyfresko SBS SAP, Polyfresko SBS SAP FR, Elastoflex SA P,
Elastoflex SA P FR, Elastoflex SA PG sI elf adhered.
Surfacing:
i
(Optional) Install one of the approved surfacing products listed in Table 4 to
obtain desired coating or required fire classification.
Maximum Design
Pressure:
-97.5 sf . See General limitation V
p ,{ )
NOA No.: 08-0226.06
Expiration Date: 10/11/12
MIAMI.flaoFcouHrir .Approval Date: 01/28/09
Page 18 of 20
Deck Type 1:
Wood, Non -Insulated
Deck Description:
19/32" or greater plywood or wood plank fastened to supports spaced 24" o.c. and
to blocking members spaced 48" o.c. with #l0x3" wood screws spaced 6" o.c.
System Type E(5):
Base sheet is mechanically attached to roof deck.
All General and System Limitations apply.
• I
Base Sheet:
One ply of Elastobase or Elastobase P fastened to the deck as described below:'
Fastening:
Attach base sheet using 12 ga, ring shank nails and tin caps spaced 4" o.c. in a 4"
lap and 4" o.c. in four equally spaced staggered rows in the center of the sheet.
Ply Sheet:
One or more plies of Elastoflex SA V or Elastoflex SA V FR self -adhered.
Membrane:
One ply of Polyfresko SBS SAP, Polyfresko SBS SAP FR, Elastoflex SA P,
Elastoflex SA P FR, Elastoflex SA PG ielf adhered.
Surfacing:
(Optional) Install one of the approved surfacing products listed in Table 4 to
obtain desired coating or required fire classification.
Maximum Design
Pressure:
-112.5 psf; (See General limitation V.)
Deck Type 1:
I
Wood, Non -Insulated
Deck Description:
19/32" or greater plywood or wood plank,lfastened to supports spaced 24" o:c. with
#8x3" wood screws spaced 6" o.c.
System Type E(6):
Base sheet is mechanically attached to roof deck.
All General and System Limitations apply. ,
Base Sheet:
One ply of Elastobase or Elastobase P fastened to the deck as described below:
Fastening:
12 ga. annular ring shanked nails and 1-5/8" tin -caps 6" o.c. in 4" lap and 6" o.c.
in four equally spaced staggered rows. Tin -caps are primed with PG100 Asphalt
Primer or Mule -Hide 121 Asphalt Primer.
Ply Sheet:
One or more plies of Elastoflex SA V or`Elastoflex SA V FR self -adhered.
Membrane:
One -ply of Polyfresko SBS SAP, Polyfresko SBS SAP FR, Polyfresko APP SAP,
Polyfresko APP SAP FR, Elastoflex SA P, Elastoflex SA P FR, Polyflex SA P,
PolyBianko, PolyKool or Polyflex SA P 1YR self adhered.
Surfacing:
(Optional) Install one of the approved surfacing products listed in Table 4 to
obtain desired coating or required fire cl {assification.
Maximum Design
Pressure:
-112.5 psf; (See General limitation P.).
NOA No.: 08-0226.06
&MM1AM,1%WDAnQEOUNTY ;
Expiration Date: 10/11/12
Approval Date: 01/28/09
Page 19 of 20
WOOD DECK SYSTEM LmTATIONS:
1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor
sheet.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials
Directory for fire ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with
Product Control Approval guidelines. All other layers shall be adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 Ibs./sq., or mechanically
attached using the fastening pattern of the top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved
asphalt, panel size shall be 4' x 4' maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell
foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet
shall be applied using spot mopping with approved asphalt, 12" diameter. circles, 24" o.c.; or strip
mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing
a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be
placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall
be at a minimum rate of 121bs./sq.
Note: Spot attached systems shall be limited to a maximum design pressure of -45 ps£
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of
275 'Ibf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value,
as field-tested, are below 275 lbf. insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based
on a minimum fastener resistance value in conjunction with the maximum design value listed within
a specific system. Should the fastener resistance be less than that required, as determined by the
Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida registered
Professional Engineer, Registered Architect, or Registered Roof Consultant may be submitted. Said
revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application
Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these
areas. Fastener densities shall be increased for both insulation and base sheet as calculated in
compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed
by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant
(When this limitation is specifically referred within this NOA, General Limitation #9 will not
be applicable.)
8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs
shall conform to Roofing Application Standard RAS I I I and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e.
field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for
enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners).
(When this limitation is specifically referred within this NOA, General Limitation #7 will not
be applicable.)
END OF THIS ACCEPTANCE
NOA No.: 08-0226.06
Expiration Date: 10/11/12
Approval Date: 01/28/09
Page 20 of 20