HomeMy WebLinkAboutSUBMITTED PAPERS.-o
DATE: FEES DL,_
#: Permit #:
- -- = - -_ Planning & Development MKiYeg D'epartir,
o Building & Code Regulation Division
o 2300 Virginia Avenue
Ft. Pierce, FL 34982-5652
Tel. 772-462-1553
APPLICATION FOR ROOF PERMIT
SEE REVERSE SIDE FOR INSTRUCTIONS
1. Location/Site Address: 6 La Villa court.
2. Parcel ID Number: 1301-113-0001Ld
S
Sc'q QED
sy
St Zuci
sty
Office Use
Section
Township
Range
Map Page
I Zoning
Land Use. I
Initials
Only
Li
P
3. Description of Project or Work Activity: remove roofing. Dry in with two layers of felt. Install OC shingles
4. Total Roof Area (square feet): 1700. 5. Roof Pitch: 21/2 in 12.
6. Type of Roof:
[ X] Fiberglass Shingle
[ ( ] Tar & Gravel
[ ] Concrete Roof Tile [ ] Wood Shake / Shingle
[ ] Modified Bitumen [ ] Other
[ ] Product Approval required for all types of Roofing Material (2 Sets)
[ ] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product
Approval attached
** Roof Mitigation per F.S. 553.844 will be required.
7. Owner Information 8. Contractor Information
Name: Wynne Building Corp. c/o Mr. and Mrs Suprun
Address: 1204 122nd Ave, Miami, FL 33186.
City: _
Zip:
State:
Phone: 413-588-8166.
FL Reg/Cert #: CC-0057399
County Cert #: 16414
Business Name: Trade Winds Roofing Inc
Cell Phone: 772-466-9420
9. Value of Construction: $ 5,150
"Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval.
CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all of a in ation contained in this.application is correct and that all work will be
done in compli wi 1 applicable la lating construction and zoning.
Michael Miller
PRINT QUALIFIERS/OWNERS NAME SIGNATURE OF QUALIFIER/OWNER
STATE OF FLORIDA, COUNTY OF !G e t e
ACKNOWLEDGED BEFORE ME THIS _ DAY OF IJO t%C?"'04'2-20 YZ, BY /21 1 /Ld LLB/-Z
WHO IS PERSON/ALLY KNOWNN®,>� TO ME -�f AS IDENTIFICATION
SCpTf.A MILLER
SIGNATURE OF NOTARY TYPE OR PRINT NAME OF NOTARY s r_ MY CDMMISSJDN # DD 932717
- ` EXPIRES: November 29, 2013
COMMISSION NUMBER , Bonded Thru Notary Public Underwr ters
,�
NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE
FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
Revised 4/26/2010
JOSEPH E. SMITH, CLERHY— ,THE CIRCUIT COURT,— SAINT LUCIE COU�T--z
FILE # 3768016 OR BOC, 52 PAGE 19.1,0, RecGrded 11/09/2012 1 2:49 PM
Permit No.
NOTICE OF COMMENCEMENT
Tax Folio No. 1301-113-0001-000/1
State of Florida County of St. Lude
The undersigned hereby gives notice that improvement will be made to certain real property, and In accordance with Chapter 713, Florida Statutes,
the following Information is provided In this Notice of Commencement
Legal Description of Property: (and street address if available):
6 La Villa Ct, Fort Pierce, FL 34951 Sect: 6 TWP 345 Range 39E
General description of Improvement: reroof
Owner Information or lessee information if the Lessee contracted for the Improvement:
Name Winn Corp clo or Eleanore Suprun
Address 12804 SW 122nd Ave., Miami, FL 33186
Interest in property:
Name and address of fee simple titleholder (if different from Owner listed above):
Contractor's Name: Trade W(nds Roofing inc.
Contractor Address: ox ort rerce VL J4979 Phone Number:772-466-947
Surety (if applicable, a copy of the payment bond is attached): Amount of bond: $
Name and address: Phone number:
Lender Name: Phone Number:
Lender's address:
Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section
713,13(1) (a)7., Florida Statutes:
Name: Phone Number:
Address:
In addition to himself or herself, Owner designates of
Uenors Notice as provided in Section 17 3.13(1) (b), Florida Statutes.
Phone number of person or entity designated by owner.
to receive a copy of the
Expiration date of notice of commencement: (the expiration date may not be before the completion of construction and final payment to the
contractor, but will be 1 year from the date of recording unless a different date is specified)
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED
IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE 10B SITE BEFORE THE FIRST
INSPECTION. IFYOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR
RECORDING YOUR NOTICE OF COMMENCEMENT.
Under penalty of perjury, I declare that I have read the foregoing notice of commencement and that the facts stated therein are true to the best of
my knowledge and belief., _
[�✓uA)
(Signature of Own or LessA, or Owners or Lessee's Authorized Officer/Director/Partner/Manager
i wf)er
(Signatory's Title/Office)
The foregoing instrument was acknowledgedbefore methis Po dayof /�
By f; leomc M S�rull as Owner' for Sew I t^
me of Person Type of authority (e.g. officer, trustee) Party on behalf of whom instrument was executed
r
Personally known_ or produced Identification_
(S ure of Notary Public - State of Florida) r fr�1
(Print, Type, or Stamp Commissioned Name of Notary Public) Type of Identification produced r LA1 I--
sr • GLENDAKLINONER
**sign in front of a notary ? Notary Public, State of Rodda
Commissf.0 EE 07472
My comm. expires Apr. 25, 2015
STATE OF FLORIDA
ST. LKIE COUNTY
THIS IS TO CERTIFY THAT THIS ISA
T xj:E:1 DCORUOTCOPY OFT 14E
Or PNIAL /
JOSH E SMITH, CLERK
BY:
4mts
Florida Building Code Online i=
Page 1 of 2
1
e WE t ®Pit
Florida Dep amend BCIS Home i Log In ', User Registration ; Hot Topics Submit Surcharge 1 Stats & Facts
Busines) Product Approval
Professi �I .^ xl USER: Public User
Regulation
e lit
f1LL"`� ""atiii�rrsar urar�i
Publications FBC Staff BCIS Site Map I Links j Search
Product Approval Menu > Product or AODlication Search > Application List > Application Detail
FL # FL10674-R6
Application Type Revision
Code Version 2010
Application Status Pending FBC Approval
Comments
Archived
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo, OH 43659
(740) 404-7829
greg.keeler@owenscoming.com
Authorized Signature Greg Keeler
greg.keeler@owenscoming.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Coming PKWY
Toledo, OH 43659
(419) 376-8360
mel.sancrant@owenscomig.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method
Florida Engineer or Architect Name who
developed the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
#1411p7i
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Robert J.M. Nieminen
PE-59166
Underwriters Laboratories Inc.
09/26/2014
John W. Knezevich, PE
Validation Checklist - Hardcopy Received
FL10674 R6 COI Trinity ERD CI - Nieminen.odf
Standard Year
ASTM D3161, Class F 2006
ASTM D3462 2007
ASTM D7158, Class H 2O07
http://www.floridabuilding.org/pr/pr-app_dtl.aspx?param=wGEVXQwtDgtBNbEYSV%2... 3/29/2012
Florida Building Code Online
- Page 2 of 2
1
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 02/16/2012
Date Validated 02/21/2012
Date Pending FBC Approval 02/24/2012
ICummary of Drndurtc
FL # IlModel.
Number or Name IlDescription
10674.1
Owens Corning Asphalt Roofing
3-tab, laminated, starter, and hip & ridge
Shingles and Starters
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL10674 R6 II er020612FINAL OC FL10674-
R6 Asphalt Shingles.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert J. M. Nieminen PE - 59166
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: Refer to ER, Section 5.
Evaluation Reports
FL10674 R6 AE er020612FINAL OC FL10674-
R6 Asphalt Shinales.pdf
Created by Independent Third Party: Yes
Back Next
Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, e-mail addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not
send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions regarding DBPR's ADA web
accessibility, please contact our Web Master at webmasterOdbor.state.0.us.
Product Approval Accepts:
® ® eChwi.
IM
securimm m uic:
VnlSlpn • '-
Tr
http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtBNbEY5V%2... 3/29/2012
TRINITY ERD
Certificate of Authorization #9503
August 01, 2011
RE: Certification of Independence, Florida F.A.C. Rule 9N-3
To Whom It May Concern:
This letter serves to document the following in accordance with Florida F.A.C. Rule 9N-3:
I . Exterior Research & Design, LLC. d/b/a Trinity I ERD does not have, nor does it intend to acquire or
will it acquire, a financial interest in any company manufacturing or distributing products it evaluates.
2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any
company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company
manufacturing or distributing products for which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved
in the approval process of the product.
Please contact our office with any questions.
Sincerely,
Robert Nieminen, P.E.
Florida Reg. No. 59166
Vice President
Email: robertnieminen@trinityerd.com
EXTERIOR RESEARCH & DESIGN, LLC. d/b/a TrinitylERD - Certificate of Authorization #9503
MAIN: 80 Yesler Way • Suite 200 . Seattle, WA 98104 . P: (206) 467-0054 . F: (206) 467-5840
EAST: 353 Christian Street Unit 13 . Oxford, CT 06478 • P: (203) 262-9245 • F: (203) 262-9243
TRINITY ' ER®
EVALUATION REPORT
Owens Corning
One Owens Corning Parkway
Toledo, OH 43659
EXTERIOR RESEARCH & DESIGN, LLC.
CertiFcate of Authorization #9503
353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
Evaluation Report 037940.02.12
FL10674-R6
Date of Issuance: 02/06/2012
SCOPE:
This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing
the use of construction materials in the State of Florida. The documentation submitted has been
reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and
Florida Building Code, Residential Volume. The products described herein have been designed to
comply with the 2010 FBC and 2010 FBC Residential Volume sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality
Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)
changes, the referenced Quality Assurance documentation changes, or provisions of the Code that
relate to the product change. Acceptance of this Evaluation Report by the named client constitutes
agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality
Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation
Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may
be displayed in advertising literature. If any portion of the Evaluation Report is displayed; then it
shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by
the manufacturer or its distributors and shall be available for inspection at the job site at the
request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized
by Robert Nieminen, P.E. on 02/06/2012
This does not serve as an electronically signed
document Signed, sealed hardcopies have been
transmitted to the Product Approval Administrator and
to the named client
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity[ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which
the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
TRINR Y ER®
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category:
Roofing
Sub -Category:
Asphalt Shingles
Compliance Statement:
Owens Corning Asphalt Roof Shingles, as produced
by Owens Corning, have
demonstrated compliance
with the following sections of the Florida Building
Code and Florida Building
Code, Residential Volume
through testing in accordance with the following Standards. Compliance is
subject to the Installation
Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1507.2.5, R905.2.4
Physical Properties
ASTM D3462
2007
1507.2.7.1, R905.2.6.1
Wind Resistance
ASTM D3161, Class F
2006
1507.2.7.1, R905.2.6.1
Wind Resistance
ASTM D7158, Class H
2O07
3. REFERENCES:
Entity
Examination
Reference
Date
UL (CER1739)
Physicals & Wind Resistance
File R2453, Vol. 3
02/15/2007
UL (TST1740)
Physical Properties
06CA20263
04/18/2006
Miami -Dade (CER1592)
FBC HVHZ Compliance
07-1116.12
02/14/2008
Miami -Dade (CER1592)
FBC HVHZ Compliance
09-0915.12
12/16/2009
Miami -Dade (CER1592)
FBC HVHZ Compliance
10-0817.09
10/27/2010
Miami -Dade (CER1592)
FBC HVHZ Compliance
10-0817.10
10/27/2010
Miami -Dade (CER1592)
FBC HVHZ Compliance
10-0817.08
10/27/2010
Miami -Dade (CER1592)
FBC HVHZ Compliance
10-0817.07
10/27/2010
Miami -Dade (CER1592)
FBC HVHZ Compliance
11-0411.03
06/16/2011
Miami -Dade (CER1592)
FBC HVHZ Compliance
11-0919.05
10/13/2011
UL (QUA1743)
Quality Control
Service Confirmation
Exp. 09/26/2014
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic° and Supreme° are fiberglass reinforced, 3-tab asphalt roof shingles.
4.1.2 Berkshire° are fiberglass reinforced, 4-tab asphalt roof shingles.
4.1.3 Duration°, Duration° Premium, OakridgeO and WeatherGuard° HP are fiberglass reinforced,
laminated asphalt roof shingles.
4.2 Berkshire° Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant and WeatherGuard° HP
Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles.
4.3 Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
S. LIMITATIONS:
5.1 This Evaluation Report is not for use in the HVHZ.
5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing
Materials Directory for fire ratings of this product.
5.3 Wind Classification:
5.3.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables
1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating
the shingles are acceptable for us in all wind zones up to Vasd = 150 mph (V„it = 194 mph).
Refer to Section 6 for installation requirements to meet this wind rating.
Exterior Research and Design, LLC. Evaluation Report 037940.02.12
Certificate of Authorization #9503 FL10674-R6
Date of Issuance: 02/06/2012
Page 2 of 6
TRINITY, ERA
5.3.2 All Owens Corning hip & ridge shingles and Starter Strip Plus noted herein are Classified in
accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the
shingles are acceptable for us in all wind zones up to Vasd = 150 mph (V„It = 194 mph). Refer
to Section 6 for installation requirements to meet this wind rating.
5.3.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60
feet or less. Calculations by a qualified design professional are required for conditions outside
these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.3.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.4 All products in the roof assembly shall have quality assurance audit in accordance with the
Florida Building Code and F.A.C. Rule 9N-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide
Product Approval, or be Locally Approved per Rule 9N-3, per FBC Sections 1507.2.3, 1507.2.4
or R905.2.3.
6.2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published
instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2
or R905.2, with the following exceptions:
➢ Berkshire° shingles require minimum five (5) nails per shingle.
➢ WeatherGuardO HP shingles require minimum six (6) nails per shingle.
➢ Starter Strip Plus requires minimum five (5) nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less
than FBC 1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of
fastening are required. Contact the shingle manufacturer for details.
6.2.5 Minimum Nailing — Classic® & Supreme:
Normal Mansard or Area pare
Wind Areas High Wind desvanasy
Area porn vientos normalos Areas viontos Mertes
rt" IAI r Fr
S Exposure
Exposition
Exterior Research and Design, LLC.
Certificate of Authorization #9503
Normal. Mansard or Area pore
Wind Areas High Wind desvonos y
Area pars vientos normales Areas vionros fuortas
ttz t (Al tz t t rr z•z I61 z' t'
1
5 5/8' Exposure
Exposition
Evaluation Report 037940.02.12
FL10674-R6
Date of Issuance: 02/06/2012
Page 3 of 6
6.2.6 Minimum Nailing - Berkshireg:
6.2.7 Minimum Nailing - Duration® & Duration® Premium:
4 Nail Pattern
Esquema de 4 clavos
SureNailPfastening area width
Area de clawsSuteWP
EL
r
5:P Exposure Nails SV Exposure
5".5 pulg. c+a exposlddn cfp ypg � S;Spulg. de exposie(drt
6.2.8 Minimum Nailing - Oakridgep:
4 Nail Pattern
Esquema con 4 clavos
r r
55B" Exposure5 W' Exposure
Ex oslddnde55/S ul . laNails Ex sid6nde6618 of .
P P 9 Claws Po P 9
Exterior Research and Design, LLC.
Certificate of Authorization #9503
TRINITY ERD
6 Nail 9oisaraaid Seep Sbpr
tstenb! ,isuteuaA°
Pattern areaana! doutod.
Esque a — cbmartb opet¢:der
de6de mv, otparastrpda V"d
• • • %+aSurthpybpA2
'-'� >c9TUCfrink.
sunnare' sd YaiN
laslert \ tsfmin
ateatrr� \ anarvi�n
cbves 7' \ \r lows
suuuaa� t_ tz• —� \ \ <-- tr suteaaiF
LE • ON
o
91, Exposure Flails ST Exposure
5%pulg. do exposloWn CfavoS Phpulg. do expos(ddn
6 Nail Pattern
Esquema cons Claws
r r
5 516" Exposure
Nails
5 6/6" Exposure
Fsposidon de 55/6 puig.
Expasicidn de 55/9 pulg.
Evaluation Report 037940.02.12
FL10674-R6
Date of Issuance: 02/06/2012
Page 4 of 6
TRINITY' ERD
6.2.9 Minimum Nailing - WeatherGuard® HP:
:E s,
a.t-1a�71..gp FM Urn
dw"o6i�3!#sJb
6.3 Hip & Ridge Shingles:
6.3.1 Installation of Berkshire° Hip and Ridge Shingles, High Ridge, Hip & Ridge with Sealant and
WeatherGuard° HP Hip and Ridge Shingles shall comply with the manufacturer's current
published instructions, using four (4) nails per shingle. Refer to Owens Corning published
information on wind resistance and installation limitations, including the use of hand -sealing for
wind warranties.
6.3.2
6.3.3
6.3.4
Fasteners shall be in accordance with the manufacturer's published requirements, but not less
than FBC 1507.2.6 or R905.2.5. Staples are not permitted.
Minimum Nailing — Berkshire® Hip & Ridge and High Ridge:
Fig.1 Q
�— PiewailingWind
D'uedion A
Nails* zn\
Q
A I I
F I I
I I
Q I I
1 I 1 I
1
Exposure
Minimum Nailing - Hip & Ridge with Sealant:
em Fig. 2 - High Wiled Fastening Patte+m
(14 Nails)
Trim Shinl9ta
and Discard 2" 2"
Excess ��.
Sealant -;
Strip T s e '12"
' Fastening 61Y, S"Exposure
Distance
12 "
Fig. 2
TopVjai shloxnav
Nails Nails
TapLminated
4" Piece
1
I
I
I
JI
I
ul
1
I
I
I
72" I
Exterior Research and Design, LLC. Evaluation Report 037940.02.12
Certificate of Authorization #9503 FL10674-116
Date of Issuance: 02/06/2012
Page 5 of 6
6.3.5 Minimum Nailing - WeatherGuard® HP Hip and Ridge:
Fig. A v 4
prevaning rgntl
S- Dlrectbn A
A
flails 4 4
I I
A
1 I
I I 1 I
A I I
A I I 1 I
Exposure
TRINITY, ER®
Fig. C Hip & Ridge Shingle Fastening
Top~
flails flails
r'
2" 2"
t° o-� t•
'T•, t„I
s' Exposure
72
7. LABELING:
7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo
of the Accredited Quality Assurance Agency noted herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications
detailed in FBC Table 1507.2.7.1 / R905.2.6.1.
S. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the
installation of this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule
9N-3 QA requirements.
10. QUALITY ASSURANCE ENTITY:
Underwriters Laboratories - QUA1743; (414) 248-6409; karen.buchmannCclul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, LLC. Evaluation Report 037940.02.12
Certificate of Authorization #9503 FL10674-116
Date of Issuance: 02/06/2012
Page 6 of 6