Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSDATE: CEIPT: PERMIT NUMBER: PL NNING & DEVELOPMENT SERVICES DEPARTMENT p BUILDING & CODE REGULATIONS DIVISION Q 1 2300 Virginia Avenue U v r Fort Pierce, FL 34982 (772) 462-1553 APPLICATION FOR REPLACEMENT OF �F; `4 r�1IN WINDOWS, SKYLIGHTS,&OVERHEAD GARAGED ORS GLASS DOORS �,� i 0,� 1. LOCATION/SITE ADDRESS: bS 2. PARCEL ID NUMBER: 2JiZ Z - L^O -7 —Obi{ Mo -7 3. DESCRIPTION OF PROJECT OR WORK ACTIVITY: W IN7n tA I .po6G �bJ 4. TYPE OF STRUCTURE: SFR 1 MOBILE HOME OTHER { 5. OWNERS INFORMATION ' 6. CONTRACTOR'S INFORMATION Name: Y�l GTnI'r'l(12E FL Reg/Cert#: C%G Address: Z�oy. (o06d County Cert #: City:104I � 13t',a<,W State: _ Business Name: �rd1, SCr' �l.'79tilr Wn� ���wl Zip: 3 Phone: OZ�I �c17 a Phone Number: ( el L-Z7GIo Email: Email: j4AIG4A-P_! _L.2ooa'/N a, Car" 'COMPONENT'ID PROD CT=DESIGN,PRPSSURE I"RODUCT APP)[1QVAL #, ..: WINDOWS •1'�jh To onre f [] Attach 2 copies of the Produ t Approval with details VALUE OF CONSTRUCTION: $ ( FEES DUE: OWNER'S AFFIDAVIT: I certify that all of the Information contained i IS Ci compliance with all applicable laws regula g con ctia ' PRINT OWNER OR STATE OF FLORIDA, COUNTY OF 111191A,' 1i ED BEFORE ME THIS III AY OF C�/• , 20 2- , BY TITLE: NOTICE TO YOUR to the product being used. TURE OF OVANER OR I that all work will be done in O LLY �TO ME O WHO HAS PRODUCED � O�PRY P�d� Notary Public State.or Florida John Lee 7inney F N TARY TYPE OR PRINT NAME OF NO MY C$'ENL'if>9ziE on E024587 Esp;re�'.t./t5/?.014 1RY PUBLIC COMMISSION NUMBER• OWNER: FAILURE TO RECORD A6NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS OPERTY. IF YOU INTEND TO O> TAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING E OF COMMENCEMENT. V JOSEPH E. SMITH, CLERK OF THE CIRCUIT COURT - SAINT LUCIE COUNTY FILE # 3773157 OR BOOK 391"' PAGE 1055, Recorded 11/28/2012 at 0, .1 AM tiJ Permit No. State of Florida County of St. Lucie NOTICE OF COMMENCEMENT t Tax Folio No. 3f22-Go"1-m8ti-coo/7 The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the fallowing Information Is provided In this Notice of Commencement. Legal Desaiption of Property: (and street address If available): i�uNE WfFuL R,y 'I"Nf ry�Ar! a�A S�t,�►� /aot.s.g� IV,,trf-t! ljf ob 5 (/rv17-9G General description of Improvement:_ 0." OiDW owner info tion or lessee Information If the Lessee contracted for the improvement: Name -r Address Interest In property: .V Name and address of fee simple titleholder (ifdiffe4ent from Owner listed above): Contractor's Name: Jw 4 rv14- JWt- Contractor Address: y27 ' 1 7h1, < hone Number ZOOS O Surety (if applicable, a copy of the payment bond it attached):): Amount of bond: $ Name and address: I Phone number: Lender Name: f Phone Number: Lender's address: i Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided bySection 715.13(1) (a)7., Florida Statutes: Name: _- Phone Number: Address: In addition to himself or herself, Owner designatesl of to receive a copy of the Lienor's Notice as provided in Section 713.13(1) (b Florida Statutes. Phone number of person or entity designated by oivner: Expiration date of notice of commencement: (the expiration date may not be before the completion of construction and final payment to the contractor, but will be 1 year from the date of recolrding unless a different date Is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY r 'E OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PAR 11, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING. WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. I 1 Under penalty of perjury, I declare that I have readtheforegoing notice of commencement and that the facts stated therein are true to the best of my knowledge and belief. (Signature a# Owner or Lessee, or Ownerl or Less¢e's Authorized Officer/Director/partner/Manager (Signatory's Title/Office) I The fore nginstrumenewacknowledgedbefo me this/ day of CCI! , 20LJ, ey , + 7 FL as i %1'O,UuP2 for1111,66# `1 Na a of�arxrr ,Type of au ority (e.g. officer, trustee) Party on If of wh nstrument was executed r , 1 f r a n or produced Identification ( gnature of Notary Public • of Flodda) I r,�V"0¢� Notary Public Slate of Flonda (P int, Type, or Stamp Co Issio Name of Notary Public) ,a~ MY COMml„i a ntific Ion produced aryl►L44ds�dlF or w Expilo 1111512014 I i STATE Of FLORIDA ST. LUCIE COUNTY TH TR OR By Da r % OCEAN SIDE LEGEND: TYPICAL 8" MASONRY LOCATION OF WINDOW/DOOR REPLACEMET (SEE WIND PRESSURE CHART FOR SIZES) NOTE: f STRUCTURAL DES� I T10 THE ; ROPO RENOVATIONS Dq l.O TR'. RA -. REMAINING EXISj� IG AT 4 �L SYSTEMS AND A REQUIREMENT T( UP RADE IT BY THIS PERMIT APPLICATION IS NOT WARRANTED. EXISTING BUILDINGS COMPONENTS AND ELEMENTS OUTSIDE THE REPLACEMENT WINDOW AREA WILL NOT HAVE THEIR CURRENT WIND LOAD RESISTANT CAPACITY COMPROMISED BY THE PROPOSED NEW CONSTRUCTION. APPROVAL OF THESE PLANS IN NO WAY RELIEVES THE CONTRACTOR OR BUILDER OF COMPLYING WITH ORDINANCES OF LOCAL, STATE OR FEDERAL BUILDING DEPARTMENTS. NOTE: ALL WINDOWS SHALL BE PER ASCE 7-10, 170 MPH, EXPOSURE "D" INTERNAL PRESSURE COEFFICIENT: t0.18 RIDGE HEIGHT ESTIMATED = t86'-0" ALL ELEVATIONS FOR CALCULATIONS FROM JENSEN BEACH ALUMINUM. CONTRACTOR TO VERIFY IN FIELD RIDGE HEIGHT OF BUILDING. ....................................... ....................................... BALCONY ....................................... ....................................... ................. O _.......:_ FLOOR PLAN 00 1 UNIT #516 - FLOOR 5 Scale: NTS **NOTE: WIND PRESSURES HAVE BEEN CALCULATED USING ALLOWABLE STRESS DESIGN FACTOR OF 0.6. WILLIAM J. MATHERS, PE FL # 19658 AS PER THE NOTICE REQUIREMENTS OF 61G15-30.003(l) F.A.C., THIS DOCUMENT IS BEING TRANSMITTED TO THE PUBLIC AGENCY TO RECEIVE AGENCY REVIEW, COMMENTS AND INTERPRETATIONS. THE DOCUMENTS MAY SUBSEQUENTLY BE REVISED BY THE ENGINEER TO REFLECT RESOLUTION OF ISSUES WITH THE PUBLIC AGENCY PRIOR TO FINAL ACTION BY THE AGENCY. CHANGES, REVISIONS AND MODIFICATIONS TO A PROJECT MAY PROMPT ADDITIONAL DOCUMENT SUBMITTAL FOR AGENCY APPROVAL ACTION ON THE SAME PROJECT. THE MOST CURRENT DATE OF THE ENGINEER OF RECORDS SIGNATURE ACCOMPANYING THE PUBLIC AGENCY S WRITTEN APPROVAL DESIGNATES THIS DOCUMENTS FINAL FORM. DUNE WALK - UNIT #516 2431 T, FL 3 96 PHONE- (772) 287-0525 STUART, FL 34996 FAX: (772) 220-8686 7370 SOUTH OCEAN DRIVE JENSEN HEACH, FL 34957 EB 0002026 EA C002026 DI�—ri NEW WINDOW: WIND PRESSURE CHART MATHEERE ENGINEERING CORPORATION CIVIL STRUCTURAL ARCHITECTURE LAND PLANNING VK_INDOW/DOOR SCHEDULE NO APPDX SIZE OPENING (�l�/j H) ? ' DESIGNATION ** TYPE IMPACT PROTECTIONID REMARKS IMPACT GLASS NEW SHUTTER * EXISTING SHUTTER 37" X 63" 25 SH X EXAMPLE 1 l S 211010 Z 1 SLA D PN6 3 4 ; 5 6 7 8 9 10 s f 12 13 i 14 15 16 17 . I 18 i I 19 I 20 22 i 23 24 25 26 i 27 28 29 i 30 I *Window Replacement,using hxisting'shcitters to comply with impact; protection will require the existing shutters to meet the rt6iremeents of the 2007 FBe esidential R301o2.1.2 TOTAL GLAZED OPENING ARIA FOR STRUCTRE: S'.F. i PERCENTAGE OF NEW, LAZE AREA: (TUG4L INSTALLED GLAZED ARE2 DIVIDED BY TOTAL GLAZED OPENINGS FOR STRUCTURE) NOTE: The replacement of more than 25 /o of the aggregate area of exterior glazit g,(wind ows.& doors) in one & two family dwellings within a 12 month period will r quire impact protection on all proposed glazed opening replacement (approved shutters or impact resistant glazing) as } er 2007 F C/ EXISTING BUILDING 606.4. ! i ** TYPE WINDOWS I SH - SINGLE HUNG A.WN - AWNING Sir"SLIDING i DH -'DOUBLE HUG CAS- CASEMENT FIX - FIXED, I 5 i Florida Building Code Online T Page 1 of 4 BCIS Home Log In User FL# " R< Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Hot Topics Submit Surcharge i Stats & Facts Publications 1 FBC Staff i BCIS Site Map Links i Search Technical Representative �{ Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory N Compliance Method 1 Certification Agency Validated By > Application List > Application Detail Revision 201r097, s . App oved *Approved by DCA. Approvals by DCA shall be reviewed and ratified by the POC and/or the Commission if necessary. Referenced Standard and' ear (of Standard PGTIndusthies 1070 Technology Drive Nokomis, FL 34275 (941)486-0100 Ext22318 druark@pgtindustries.com Jens Rosowski jrosowski@pgtindustries.com Jens Rosowski 1070 Technology Drive Nokomis, FL 34275 (941)486-0100 Ext21140 jrosowskl@pgtindustries.com , " Ezter'�Do (Sliding Exterior Door Assem611es Certification Mark or Listing Miami -Dade BCCO - CER Miami -Dade BCCO - VAL Standard r TAS 201, 202, 203 I TAS 202 G Equivalence of Product Standards Certified By Product Approval Method Method 1 Option pt on A http://www.floridabuilding.org/pr/pL app_dtl.aspx?param=wGEVXQWtDgsEt2PTand5bm Year 1994 1994 11/5/2012 Florida Building Code Online Date Submitted 08/16/2012 Date Validated 08/16/2012 Date Pending FBC Approv, I Date Approved j 08/19/2012 Page 2 of 4 Summary of Products , FL # IMode, Number or Name iDescription 251.1 1 SGD - 470 (Non -Impact) IVinyl Sliding Glass Door Limits of Use I Certification Agency Certificate Approved for use in HVHZ: Yes FL251 R17 C CAC 11-1018.20.pdf Approved for use outGlde HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: NoT 04/21/2016 Design Pressure: N/A Installation Instructions Other: Please see Mia !-Dade County Notice of FL251. 11 11.-1018...2d,,,pdt Acceptance NO for product performance information, Verified By: Miami -Dade BCCO - CER anchorage details, and abchor type, size, and spacing Created by Independent Third Party: information. { Evaluation Reports f Created by Independent Third Party: 251.2 SIGD - 570 (Large Missile Impact) Vinyl Sliding Glass Door Limits of Use Certification Agency Certificate Approved for use in HZ: Yes FL251 R17 C CAC 11-1018.19.odf Approved for use out ide HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 04/14/2016 Design Pressure: N/A I Installation Instructions Other: Please see Mia '-Dade County Notice of FL251_R17 II 11,-10_18.19.,p f Acceptance (NOA) for product performance information, Verified By: Miami -Dade BCCO - CER anchorage details, and anchor type, size, and spacing Created by Independent Third Party: information. Evaluation Reports Created by Independent Third Party: 251.3 Jj§GD - 670 (Non -Impact) Aluminum Sliding Glass Door Limits of Use (I Certification Agency Certificate Approved for use in HZ: Yes FL251 R17 C CAC 11-1018.17,pdf Approved for use out ide HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 04/07/2015 Design Pressure: N/A Installation Instructions Other: Please see Mia Dade County Notice of FL251 R17 II 11-1018.17.pdf Acceptance (NOA) for pr duct performance information, Verified By: Miami -Dade BCCO - CER anchorage details, and aIhchor type, size, and spacing Created by Independent Third Party: information. Evaluation Reports Created by Independent Third Party: 251.4 D - 670HP (Non -Impact) Aluminum Sliding Glass Door Limits of Use r Certification Agency Certificate Approved for use in HZ: Yes FL251 R17 C CAC 11-1018.18.pdf Approved for use out ide HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 03/24/2015 Design Pressure: N/A , Installation Instructions -Dade County Notice of Other: Please see Miajachor FL251 R17 II 11-1018.18.pdf Acceptance (NOA) for pduct performance information, Verified By: Miami -Dade BCCO - CER anchorage details, and type, size, and spacing Created by Independent Third Party: information. 4 Evaluation Reports Created by Independent Third Party: 251.5 D - 680 (Non -Impact) WinGuard Aluminum Sliding Glass Door Limits of Use Certification Agency Certificate Approved for use in HZ: Yes FL251 R17 C CAC 11-1018,13.ndf Approved for use out 'ide HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 03/18/2014 Design Pressure: N/A Installation Instructions Other: Please see Mianj -Dade County Notice of FL251 R1.7 II 11-1018.13.pdf i Acceptance (NOA) for pr duct performance information, Verified By: Miami -Dade BCCO - CER anchorage details, and a chor type, size, and spacing Created by Independent Third Party: information. Evaluation Reports Created by Independent Third Party: 251.6 k D -r77�04(PLarge Mi'ssilerImpact_);j1WJnGuard Aluminum Sliding Glass Door Limits of Use Certification Agency Certificate Approved for use in HZ: Yes 17I-251. R1.7 C CAC 11-1.018.14.pdf Approved for use out ide HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yesi 02/17/2015 Design Pressure: N/A Installation Instructions,..-,,,,,,_.,.,-. % r Other: Please see Mia 1-Dade County Notice of FL251;R17 IIx11 1Q1£i+1 pifZ. ! ),I 1� W t http://www.floridabuilding.org/pr/pin app_dtl.aspx?param=wGEVXQwtDgsEt2PTand5bm... 11/5/2012 Florida Building Code Online Page 3 of 4 tJ; ' Acceptance (NOA) for pr duct performance Information, Verified By: Miami -Dade BCCO - CER anchorage details, and a chor type, size, and spacing Created by Independent Third Party: information. Evaluation Reports Created by Independent Third Party: 251.7 D - 770HP (Large Missile WinGuard Aluminum Sliding Glass Door Ipnpact) Limits of Use I Certification Agency Certificate Approved for use in VHZ: Yes FL251_R17 C CAC 11� 1018. 1 ..pdf Approved for use out ide HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yeg 03/24/2015 Design Pressure: N/A', Installation Instructions Other: Please see Miami -Dade County Notice of FL251 R17 II 11-1018.16.odf Acceptance (NOA) for prHuct performance Information, Verified By: Miami -Dade BCCO - CER anchorage details, and anchor type, size, and spacing Created by Independent Third Party: information. Evaluation Reports Created by Independent Third Party: 251.8 SGD - 770HP (Small Missile WinGuard Aluminum Sliding Glass Door Impact) Limits of Use Approved for use in HVHZ: Yes Certification Agency Certificate FL251 R17 C CAC 111018._15,,kdf Approved for use out`ide HVHZ: Yes Quality Assurance Contract Expiration Date ' Impact Resistant: Ye 03/24/2015 Design Pressure: N/A, Installation Instructions Other: Please see Mia 'i-Dade County Notice of FL251 R17 II 11-1018 15_pdf Acceptance (NOA) for pr duct performance Information, Verified By: Miami -Dade BCCO - CER anchorage details, and a chor type, size, and spacing Created by Independent Third Party: information. Evaluation Reports i Created by Independent Third Party: 251.9 SaD - 780 (Impact) WinGuard Aluminum Sliding Glass Door Limits of Use Certification Agency Certificate Approved for use in F VHZ: Yes FL251 R17 C CAC _12-05160 4.p_df Approved for use out ide HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Ye 08/02/2017 Design Pressure: N/A, Installation Instructions Other: Please see Mia -Dade County Notice of FL251 R17 II 12_0516.04.pdf Acceptance (NOA) for pr duct performance information, Verified By: Miami -Dade BCCO - CER anchorage details, and a chor type, size, and spacing Created by Independent Third Party: information. Evaluation Reports Created by Independent Third Party: 251.10 D-2500 (Non -Impact) Aluminum Sliding Glass Door Limits of Use jr Certification Agency Certificate Approved for use in li�VHZ: Yes FL251 R17 C CAC 11=1018.11.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 05/22/2013 Design Pressure: N/A Installation Instructions Other: Please see Mia -Dade County Notice of FL251 R17 II 11-1018.11..pdf Acceptance (NOA) for pr duct performance information, Verified By: Miami -Dade BCCO - CER anchorage details, and a chor type, size, and spacing Created by Independent Third Party: information. Evaluation Reports Created by Independent Third Party: 251.11 GD-2770 (Large Missile Impact) Vinyl Sliding Glass Door Limits of Use Certification Agency Certificate Approved for use in HZ: Yes Approved for use out ide HVHZ: Yes FL251 R17 C CAC 11-1018.19.odf Quality Assurance Contract Expiration Date Impact Resistant: Yes 04/14/2016 Design Pressure: N/A I Installation Instructions Other: Please see MianT-Dade County Notice of FL251 R17 II;11_100 19.,dfp Acceptance (NOA) for pr duct performance Information, Veri I d By: Miami -Dade BCCO - CER anchorage details, and anchor type, size, and spacing Created by Independent Third Party: information. Evaluation Reports Created by Independent Third Party: 251.12 D-2870 (Large Missile Impact) JIVinyl Sliding Glass Door Limits of Use Certification Agency Certificate Approved for use in *HZ: Yes FL251 R17 C CAC 11-1018.19.pdf Approved for use outifide HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes I 04/14/2016 Design Pressure: N/A Installation Instructions Other: Please see Mia+Dade County Notice of FL251 R17 II 11.10,18.19.�df Acceptance (NOA) for product performance information, Verified By: Miami -Dade BCCO - CER anchorage details, and anchor type, size, and spacing Created by Independent Third Party: information. i Evaluation Reports Created by Independent Third Party: http://www.floridabuilding.org/pr/p� app dtl.aspx?param=wGEVXOwtDQsEt2PTand5bm... 11/5/2012 Florida Building Code Online �Page 4 of 4 r 251.13 13-3030 (Large Missile Impact) Architectural Systems Aluminum Sliding Glass Door Limits of Use Certification Agency Certificate Approved for use in HZ: Yes FL251 R17 C CAC 11-1018.09 gdf Approved for use out ide HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Ye , 02/14/2013 Design Pressure: N/A Installation Instructions Other: Please see Miar jLDade County Notice of FL251 R17 IT 1 ] 1018 09 odf Acceptance (NO A)for pr9duct performance information, Verified By: Miami -Dade BCCO - CER anchorage details, and anchor type, size, and spacing Created by Independent Third Party: information. i Evaluation Reports Created by Independent Third Party: 251.14 SGD-3030 (Small Missile Impact) Architectural Systems Aluminum Sliding Glass Door Limits of Use Certification Agency Certificate Approved for use in H:,VHZ: Yes FL251 R17 C CAC 11-1018.10.pelf Approved for use outside HVHZ: Yes Impact Resistant: Yesi Quality Assurance Contract Expiration Date Design Pressure: N/A i 02/14/2013 Installation Instructions Other: Please see Miarrli-Dade County Notice of FL251 R17 II 11-1018 10 Ddf Acceptance (NOA) for prpduct performance Information, Verified By: Miami -Dade BCCO - CER anchorage details, and achor type, size, and spacing Created by Independent Third Party: Information. d Evaluation Reports Created by Independent Third Party: Back Next Contact Us :: 1940 North Monroe Street Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EE employer. Coovriaht 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email add re es are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this ent�. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. 'Pursuant to Section 455.275() Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: 4 http://www.floridabuilding.org/pr/p app_dtl.aspx?param=wGEVXQwtDgsEt2PTand5bm. 11/5/2012 M&A I-QsA�E I MIA1WI-DADE COUNTY o. PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING., ENVI , ONMENT, AND REGULATORY 11805 SW 26 Street, Room 208 AFFAIRS (PERA) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION 1 IViSION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/pera/ PGT Industries 1070 Technology Drive, Nokomis, Fl. 34275 SCOPE: This NOA is being issued under the applicable rules and regulations ,governing the use of construction materials. The documentation submitted has beet} reviewed and accepted by Miami -Dade County PERA -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product -Control Section (In Miami Dade County) .and or the AHJ (in areas other than Miami Dade County) reserve the right to .have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufactur r will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of uch product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is dete ined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements'of the applicable building code. This product is approved as described erein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series "SGD 7�7.OHP."Alnminum=Sl:riirio. "`''�� 's�' APPROVAL DOCUMENT: Drawi No.PGT0004 Rev C, titled "Series 770 H.P. Aluminum SGD-LMI", sheets I through 10 of 10, prepared by�manufacturer, dated 08/05/07 and last revised on 10/12/11, signed and sealed by Lynn Miller, P.E., bearing t Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration dat by the Miami -Dade County Product Control Section. :�� t MISSILE IMPACT RATING:Lar e�IyltssrteI'mpactfRe rstant�J� Limitations: 1. See table 1 in sheet 4 of this ap roved drawing set for applicable SGD unit sizes, design pressures, reinforcements, glass types, si riser and anchors requirements. 2. Egress operable doors must cTe ply with min clear width per FBC, as applicable. 3. All laminated glazing options with interior HS glass, see glazing options, sheet 1, 3 & 4. LABELING: Each unit shall bear a p' rmanent label with the manufacturee..s name or logo, city, state and series and following statement: "Miami -Dad County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be co sidered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will o our after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of a product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any o er purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be ause for termination and removal of NOA. ADVERTISEMENT: The NOA nunjber preceded by the words Miami -Dade County, Florida, and followed 'by the expiration date may be displayed i> advertising Iiterature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire 140A shall be .provided to the user by the manufacturer or its distributors and shall be available for inspection athe job site at the request of the Building Official. This NOA revises NOA # 09-0826.12 and consists of this page I and evidence pages E-1, as well as approval document mentioned above. I The submitted documentation was rev i wed by Ishaq I. Chanda, P.E. tttaMwanecounrrr NOA No 11-1018.16 Expiration Date: March 24, 2015 \` } Approval Date: December 01, 2011 \�� Page 1 PGT Industries A. DRAWINGS 1. Manufacturer's I drawings and sections (transferred from file # 09-0826.12). 2. Drawing No.PGT 004 Rev C, titled "Series 770 H.P. Aluminum SGD-LMI", sheets 1 through 10 of 10, repared by manufacturer, dated 08/05/07 and last revised on 10/12/11, signed and seated by Lynn Miller, P.E. B. TESTS (transferred fro' file # 09-0826.12) Test report on 1) Air Ilfiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94. 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclib Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411.3.2.1 (b) and TAS 202-94 Along with marked -up drawings and.installation diagram of Aluminum Sliding Glass Doors, prepared by Fenestratio4 Testing Laboratory, Inc., Test Report No FTL-5998, FTL-6005 and FTL-6012, dated 08/10/P9, all signed and sealed by Julio Gonzales, P.E. Note: The test reportso. FTL 5980 has been revised and reissued on 12/29/09, signed and sealed by Julio qonzales, P.E. C. CALCULATIONS 1. Statement letter ated OCT 14, 2011 of compliance to FBC 2007 & FBC 2010, prepared by PG , signed & sealed by Lynn Miller, P.E. 2. Statement letter 4ated 10/07/11, Successor Engineer adopting the another engineer's work per FAR 6 jG15-27-001, signed & sealed by Lynn Miller, P.E. 3. Anchor verificatibn and comparative analysis dated 08-24-09 and last revised on 12/15/09, prepar d by PTC, LLC, Robert J. Amoruso, P. E. (transferred from file # 09- 0826.12) 4. Glazing complies with ASTME-1300-02 &-04 D. QUALITY ASSURAN, �E i. Miami Dade Department of Permitting, Environment, and Regulatory Affairs (PERA). E. MATERIAL CERTIF 1.CATIONS 1. Notice of Accep ce No. 07-1116.04 issued to E.I. DuPont De Nemours & CO., Inc. for "DuPont Sen. Glas ® Plus", expiring on 01/14/2012. 2. Notice of Accep ce No. 11-0624.01 issued to "E.I. DuPont Denemours" for "DuPont Butacit� ® PVB", expiring on 12/11/16. F. STATEMENTS ' 1. Statement letter dated OCT 14, 2011 of compliance to FBC 2007 & FBC 2010 and "No financial interest", prepared by PGT, signed & sealed by Lynn Miller, P.E. I. Statement letter f conformance to FBC 2007 and no financial interest, dated 08-19- 08, signed by Ro ert.J. Amoruso, P.E.(transferred from file # 09-0826.12) 2. Letter of lab com pliance, part of the above test reports. G. OTHER 1. This NOA revise # 09-0826.12, expiring March 24, 2015. 2. Test proposals N (s) 09-0177, 0177-A, B & C approved byB CC O . L 1 Ishaq I. Chanda, P.E. Product Control Examiner NOA No 11-1018.16 Expiration Date: March 24, 2015 Approval Date: December 01, 2011 E-1 NOTES: I SLIDI 1. GLAZING TYPE OPTIONS: (GLASS RECIPES ARE FROM EXTERIOR TO INTERIOR) DESIGN PRESSURE CHART (PSF) GLASS STRENGTHS - T = TEMPERED HS = HEAT STRENGTHED INTERLAYER TYPES - SGP = .090 DUPONT SENTRY GLAS PLUS DBPVB = .090 DUPONT BUTACITE PVB SEE TABLES 1 & 1 A, SHEET 4 G4 - 7116" LAMINATED: (2) LITES OF 3/16" HS WITH AN .090 SGP INTERLAYER, G4A - 9/16" LAMINATED: (2) LITES OF 1/4- HS GLASS WITH AN .090 SGP INTERLAYER. G6 - 1" LAMINATED INSULATING GLASS: 3/16" T EXT. CAP + 3/8" AIR SPACE + 7/16' LAMINATED: (2) LITES OF 3/16" HS GLASS WITH AN .090 SGP INTERLAYER. G6A -1" LAMINATED ISULATING GLASS: 1/4" T EXT. CAP + 5/16" AIR SPACE + 7/16" LAMINATED: (2) LITES OF 3/16' I4S GLASS WITH AN .090 SGP INTERLAYER. 2. DESIGN PRESSURES: A. NEGATIVE DESIGN LOADS BASED ON TESTED PRESSURE AND GLASS TABLES ASTM E 1300. B. POSITIVE DESIGN LOADS BASED ON WATER TEST PRESSURE AND GLASS TABLES ASTM E 1300. 3. ANCHORAGE: THE 331•/ %STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT. MATERIALS, INCLUDING BUT NOT LIMITED TO STEEL SCREWS, THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE FLORIDA BUILDING CODE. FOR ANCHORAGE DETAILS SEE SHEETS 4 THROUGH 6. 4. SHUTTERS ARE NOT REQUIRED. 5. INSTALLATION SCREWS, FRAME AND PANEL CORNERS TO BE SEALED WITH NARROW JOINT SEALANT. 6. REFERENCES: TEST REPORTS FTL-5998, FfL-6005 AND FTL-6012, DATED 8/7/09. ELCO TEXTRON NOA: 07-0425.01, 03-0225.05, ANSUAF&PA NDS-2005 FOR WOOD CONSTRUCTION AND ADM-2005 ALUMINUM DESIGN MANUAL 7. THIS PRODUCT HAS BEEN DESIGNED & TESTED TO COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE, INCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVI ). 6: 909R St�iE9tuW3TBEhlEiitRED'f9RKi9MPLtANCE WITH i9RE99ftEQfiIRHNENI'9•PERft•ORIDA EbIC9{N•S E30DE; AS APPLiCA9LE: . ----- _. ..---- _.__ 9. CONFIGURATIONS: STRAIGHT DOORS - MAXIMUM 2 TRACKS BY 9 FT. (1081) HIGH WITH A MAXIMUM OF FOUR 4 FT. NOMINAL WIDE DOOR PANELS. SEE EXAMPLE ELEVATIONS AND PANEL CONFIGURATIONS ON SHEET 7. D.L.O. WIDTH = NOMINAL PANEL WIDTH - 7" D.L.O. HEIGHT = NOMINAL PANEL HEIGHT - 8.25" NOTES PERTAINING TO ANCHORAGE DETAILS ON SHEET 5.6: 1. FOR CONCRETE APPLICATIONS IN MIAMI-DADE COUNTY, USE ONLY MIAMI-DADE COUNTY APPROVED ELCO 1/4" OR 5/16" ULTRACON (FORMERLY TAPCON) CONCRETE SCREWS OR 1/4" ELCO SS4 CRETE-FLEX, SEE TABLE ON THIS SHEET FOR EMBEDMENT, EDGE DISTANCE AND SUBSTRATE REQUIREMENTS, 2. FOR WOOD APPLICATIONS USE #12 STEEL SCREWS (G5). 1/4" ELCO SS4 CRETE-FLEX MAYBE USED INSTEAD OF #12.SCREWS. 3. WOOD BUCKS DEPICTED AS 1x ARE LESS THAN 1 112' THICK. 1x WOOD BUCKS ARE OPTIONAL IF UNIT IS INSTALLED DIRECTLY TO SOLID CONCRETE WOOD BUCKS DEPICTED AS 2x ARE 1 1/2" THICK OR GREATER. 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED TO PROPERLY TRANSFER LOADS TO THE STRUCTURE. BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD. 4. FOR ATTACHMENT TO ALUMINUM: THE ALUMINUM SHALL BE A MINIMUM STRENGTH OF 6063-T5 AND A MINIMUM OF 1/8' THICK. THE ALUMINUM STRUCTURAL MEMBER SHALL BE OF A SIZE TO PROVIDE FULL SUPPORT TO THE DOOR FRAME SIMILAR TO THAT SHOWN IN THE DETAILS USING 2x WOOD BUCKS. THE ANCHORS SHALL BE #12 SHEET METAL SCREWS WITH FULL THREAD ENGAGEMENT INTO THE ALUMINUM. IF THESE CRITERIA ARE MET, THE FULL DESIGN PRESSURES USING ANCHORAGE REQUIREMENTS SHOWN IN TABLES 1, SHTS. 4, FOR ANCHOR TYPE 4 ARE ACCEPTABLE. 5. IF SILL IS TIGHT TO SUBSTRATE, GROUT OR OTHER MATERIAL IS NOT REQUIRED- IF USED, NON -SHRINK, NON-METALLIC GROUT, 3400 PSI MIN., (DONE BY OTHERS) MUST FULLY SUPPORT THE ENTIRE LENGTH OF THE SILL THAT IS NOT TIGHT TO THE SUBSTRATE, AND TRANSFER SHEAR LOAD TO SUBSTRATE. IF SUBSTRATE IS WOOD, 30# FELT PAPER OR MASTIC IS REQUIRED BETWEEN THE GROUT AND WOOD SUBSTRATE, OR AS APPROVED BY THE AUTHORITY HAVING JURISDICTION. Conant. Scmw Anchorage Minimum Embedmentand Minimum Edge DWaMa Requlmmanta Elm tatmcon WIG" Hecd and Sllt I Concrete Un.Gmuted CMU Gmuted CMU Mln. Emb. Min. Ed Min. Emb. Min. Ed Min. Emb. Min. Ed 1 31e 2 1@ 1 1/4 2 1/2 1 314 2 112 1 314 1...1/A..- ...1-1/4..• ..1_plte_ —1_.3/4..._ —2.-.1/2- 1 '3/4 2. 112-, 1'1/4 2112 "Not Reeanmen", FBC 2010 NOXONS, FL 34275 P.O. BOX 1523 NOKOMIS, FL 34274 I Elea Ultraeon i1 I DOMOOns: I CONCRETE SCREWS STRENGTHS: Fy MIN. = 135 KSI Fu MIN. = 177 KSl _ Drained CMU I toS-tIcaa2105.ZZ1.2end j RW9olthe FBC. Wood Scmws (Head, Sill & Jambs) In. Type n. Emb Min. Ed #12 Wood Screw 1 318" 1" Elco Crete -Flex SS41 1 1 318" 1 1" UNLESS OTHERWISE NOTED IES 770 H.P. ALUMINUM SGD - LMl t sm. sr.� aaaorm H.P. I NTS I 1 d 10 PGT0004 NOA DRAWING MAP SHEET GENERAL NOTES.............1 ELEVATIONS ......................2 GLAZING DETAILS ............ 3 ANCHORAGE .....................4-6 DESIGN PRESSURES.......4 ELEVATIONS ..................... 7 CON FIGURATIONS........ 7 VERT. SECT1_6N9_.:..............a HORIZ. SECTIONS ............ 6 PARTS LIST ....................... 9 EXTRUSIONS .................... 10 rRODUCT REVISED q _"pI*x with the Flerkde Udarc Cod" Atvwmaa de ri-1 o t • 1 (, 111or d- Dter o �7`w1 S �, I (,w . L�ta•tia� \c\'X01lllll/r, LYNN -` ��.•'��CENSf '•.F'P k No.58705 =_ cr p CA- 1 a Ixj if = LLI, i,SIONAL A. LYNN MILLER, RE P.E.# 58705 J . MAX. UNIT WIDTH 96" MAX. UNIT B B HEIGHT B 6 108" x0, Ox, xx MAX. UNIT B f HEIGHT B f 108" MAX. UNIT WIDTH 191 1/2" MAX. UNIT WIDTH 145 5/16" a I UNIT HEIGHT 108" OXXO APPROVED CONFIGURATIONS NO CHANGETHIS SHEET 1070 TECHNOLOGYDRrvE NOKOMIS. a34275[jj� P.O. BOX 15nSERIES NOKOMIS, fl.3a274S ELEVATIONS DER MWMI DADECOMMENTS °ER MWMI DADECOMMENTS 770 H.P. ALUMINUM SGD - LMI +m P NT3 2 e 10 a PGT0004 rawticr REV"a ..wpyltgwhh the Mwt& =Cbde gplrmh° ftxe-•-��fi"� *' No.58705 '* G STA E OF _� •.• I e l}I I I Q � ly; A LYNN/Al11LLEli` P.E. PIE.# 58ms 204 3/16' HS GLASS 12 3/1fi° HS GLASS OUPONT.090 SGP DUPONT.090 SGP EXTERIOR 3/16" HS GLASS 3116" HS GLASS 74 3/6" AIR SPACE 74 EXTERIOR 7/16' NOM. 3/16" T GLASS 1" NOM. 82 83 3/4" NOM. GLASS 3/4° NOM. 80 BITE 7 BITE 54 TRUSEAL DURASEAL SPACER •Jea.rma- LA. MINATED'.GLASS TYP.ES`G4 1" LAMINATED INSULATING 55 GLASS TYPES G6 SGP = DUPONT SENTRY GLAS PLUS rk0t)t1Ci RFv=D n ageplri"R +"� the f4wi� Q%Idl" Cads ' 205 1/4° HS GLASS 213 3/16' HS GLASS 'a bH .LL.H EXTERIOR DUPONT.090 SGP rlet DUPONT .090 SGP 3/16" HS GLASS 1/4' HS GLASS 74- 5/16' AIR SPACE 74 EXTERIOR 9H6" NOM. 1/4' T GLASS T 1° NOM. 82 83 314° NOM. GLASS 3/4" NOM. 81 BITE 79 CLASS T •• 54 z I. TRUSIEAL DURASEAL SPACER 55 9/16" LAMINATED GLASS TYPES G4A 1" LAMINATED INSULATING GLASS TYPES G6A THIS SHEET NO 0. Bo FL 34275 ILq PO. aaY f5z3 =�IJjy� J�� SERIES 770_H.P. ALUMINUM SGD - LMI NOKOMIS, FL 34274 ® ys NTS 3 d 10 � PGT0004 ,,,,Ili, OLYNN M/ ��PC1'�,.•............ �,CENS�c''•�F,Q �. ' No. 58705 * '� � � '•, !� !1 STE O� •. ATE OF i CUSS •:CZ ORMP'11, •NG\?� A. LYNN'M1IIt R. P.E. P.F-# 5B= DESIGN PRESSURE AND ANCHORAGE -HEAVY DUTY STILES -REINFORCED INTERLOCKS -HEAVY DUTYASTRAGAL TABLE 1. > HEAD & SILL (H&S) INTERLOCK & STRAIGHT & CORNERASTRAGAL CLUSTER PLUS O4TERME➢IATEANCHOR QTY. PER PANEL H & S. > JAMB ANCHOR OTY. Anchor Types; G4 - 7/16" LAMINATED GLASS- (3116" H.S. / SGP/ 3116" H.S.) 1) -1/4" ELCO ULTRACON (FORMERLY TAPCOM G4A - 9116" LAMINATED GLASS - (1/4" H.S. I SGP/ 114" H.S.) 2) "1/4" SS4 CRETE-FLEX G6 - 7116" LAMINATED I.G.U. - (3/16" TEMP. / AIR / 3/16" H.S. / SGP / 3/16" H.S.) 3) "5/16" ULTRACON GSA -7116"LAMINATED I.G.U.-(1/4"TEMP./AIR I3/16".HS./SGP/3/16"H.S.) 4) V12 STEEL SCREW (G5) ' SEEANCHORAGENOTES 1 & 2 ON SHEET 1. UNIT HEIGHT 80 84 90 f ,;- , 96, . `" a 102 108 NOM. PANEL FRAIL O ❑ OO o Z 0 V 0 O Z ❑ o o O WIDTH SIDE v N V NN N U Y N UU .} N N �.; i-N N N ^ M N GLASS TYPE - 4, 4A, 6, 6A +90-110.0 +90 -110.0 +90-110.0 +90-110.0 +90-110.0 +90-110.0 S 24 CQ+L ee+2 C Ce�2tt�10 66 8 e 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 GLASS TYPE - 4, 4A, 6, 6A +90 -110.0 +90 -110.0 +90-110.0 +90-110.0 +90-110.0 +90-110.0 m 30 g` H&S C6+2 C6+2 C6+2 C6+2 C6+2 C6+2 C6+2 C6+2 C6+2 C6+2 C6+2 C6+2 C6+2 C6+2 C6+2 C6+2 C6+2 C6+2 JAMB 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 GLASS TYPE -4, 4A 6, 6A +90-110.0 +90 -110.0 +90-110.0 (+g0'110;0yQ� p, +90 -110.0 +90 -110.0 t H&S C6+2 C6+2 �C6+2 361 C6+2 C6+p C6+2 C6+2 C6+2 C6+2 C6+2 .C6±2 E6+2, C6+2 C6+2 C6+2 C6+2 C6+2 C7+2 JAMB 10 10 10 10 10 10 10 10 1010r` 10,, ,,,10, j10 10 10 10 10 10 GLASS TYPE - 4, 4A, 6, 6A +90 -110.D +90 -110.0 +90-110.0 "-1,'49 r=110:0l jw 1T, 1 +90 -110.0 +90-110.0 42 H&S C6+2�C6+2C6+2 C6+2 CB+2 C6+2 C6+2 C6+2 CB+2 CB+2 C6+2 C7+2 C6+2 C6+2 C7+2 C6+2 C6+2 CB+2 JAMB 10 10 10 10 10 10 10 10 10 10 10 10 12 10 10 12 d GLASS TYPE - 4, 4A 8, 6A +90 -110.0 +90 -110.0 490 -110.0 +90-110.0 +9D -110.0 +g0 -110.0 48 H&S C8+2 CB+2 C6+3 C6+2 C6+2 C6+3 C6+2 C6+2 C7+3 C6+2 C6+2 C7+3 C6+2 C6+2 CB+3 C6+2 C6+2 C8+3 JAMB 10 10 I 10 10 10 10 I 10 1 10 10 10 10 1 12 10 1 10 L12 10 1 10 1 14 �` ULU WIIJIH=NUM. PANEL WIDTH -7" DLO HEIGHT = NOM. PANEL HEIGHT - 825' 1. POSITIVE PRESSURES IN TABLE ARE BASED ON THE USE OF THE 4" SILL. r OH LENGTH 2. WHEN USING THE 2 1/2' SILL, POSITIVE DP IS 46.67 PSF MAX. AND WITH THE 3 1/4' SILL, POSITIVE PRESSURES IS 60 0 PS U = EXAMPLE ON SHEETS F (NEGATIVE PRESSURES UNCHANGED). SEE TABLE 1A ON THIS SHEET. OVERHANG 3.21/2", 3 114'AND 4" SILL HEIGHTS ARE TESTED FOR WATER INFILTRATION WHEREAS OH LENGTH THE 1 1/2" SILL IS NOT AND MUST ONLY BE USED WHERE WATER RESISTANCE IS NOT OH OH HEIGHT REQUIRED. POSITIVE DESIGN PRESSURES SHOWN IN TABLE 1 MAY BE USED HEIGHT WHEN THE DOOR IS PROTECTED BY AN OVERHANG COMPLYING WITH THE FLORIDA BUILDING CODE (SEE ADJACENT DIAGRAM); THIS CONDITION IS NOT RATED FOR LI-01 Ix EQUAL TO 1 O OR GREATER WATER INFILTRATION. 4. SEE SHEETS 5 & 6 FOR ANCHORAGE SPACING AND EMBEDMENT INFORMATION. SEE NOTE 3 5. DOOR SIZE TO COMPLY WITH FBC EGRESS REQUIREMENTS. NO CHANGE THIS P.O. BOX 1529 NOKOMIS, FL 34274 HEAVY DUTY ASTRAGAL HEAVY DUTY STILES 62 111 61 68 65 68 ALL INTERLOCKS TO BE REINFORCED TABLE 1A SILL HT. VS POS. DP SILL RISE HEIGHT (+) DESIGN LOAD FLUSH - 1-1/2' N/A LOW - 2-1/2' +46.67 PSF GMT ;; 3=114; . + fio:o_.PSE MGH - 4" I + 90.0 PSF SEE NOTES 1-3 PD AND ANCHORAGE CHA iw- SERIES 770 H.P. ALUMIA s.r,nete mn• anoa 'G0770 H.P. I NTS 4 -10 ID - LMI PGT0004 fma"Cf REV11"a A�1� Ali Oc iteABa taa. I-" P��.•'• LICENSE•=�c� _ No.58705 STAEOF (V S7ONAL E,G�`• LIIIIIII110, A LYNN MILLER, P.E. P.E.#58705 T K ANCHORAGE REQUIREMENTS NOTES: 1. APPROVED ANCHOR TYPES: 1)1/4" ELCO ULTRACON (FORMERLY TAPCON) 2)1/4" ELCO SS4 CRETE-FLEX 3) 5/16" ULTRACON 4) #12 STEEL SCREW (G5) 2. ANCHOR LOCATION SPACING FOR ANCHOR QUANTITIES SPECIFIED IN TABLE 1 ON SHEET 4: HEAD & SILL ................ 8" MAX. FROM FRAME CORNERS. USE SPECIFIED CLUSTER FROM TABLE ON SHEET 4 AT EACH INTERLOCK AND ASTRAGAL LOCATION, PLUS SPECIFIED QUANTITY OF ADDITIONAL INTERMEDIATE ANCHORS PER PANEL (THE 8" FROM CORNER ANCHORS CAN BE INCLUDED). ADDITIONAL ANCHORS 24" MAX. ON CENTER. SEE EXAMPLE ANCHORAGE PLANS BELOW AND EXAMPLE CLUSTERS AT ASTRAGAL / INTERLOCKS ON SHEET B. JAMBS ......................... 6" MAX. FROM BOTTOM AND 21" MAX. O.C. UTILIZING JAMB ANCHOR QUANTITIES FROM TABLE ON SHEET 4. LOCATED BELOW - SEE CLUSTER pET., SHT. 6 - ANCHORS PER PANEL" ARE THOSE CENTER OF PANEL 3-1/2" MAX INTERLOCK 3.5" MAX. ASTRAGAL INTERIOR AT THE HEAD AND SILL BETWEEN CENTERLINE O.C. CENTERLINE 8" MAX' CLUSTERS OR THOSE BETWEEN A CLUSTER AND A FRAME JAMB. o 0 0 o 0 0 0 o I 2 04" r o-Ijo'�-h a0 0 o I EXAMPLE OXX ANCHORAGE PLAN: C8+3 HEAD & SILL ANCHORAGE Q PANEL 2-TRACK EXAMPLE SHOWN) - (25) ANCHORS TOTAL (3) PANEL, 48" x 108" DOOR FROM TABLE ON SHEET 4, ANCHOR TYPES 2 & 4 IN WOOD SUBSTRATE EXTERIOR ------------------------------------------------J �ra�swucirqe¢vec�e C8+3 = (36) ANCHORS TOTAL AT HEAD AND AT SILL 3 C8 3 C8 3 C8 3 -/a/ •/G bpkmm map i s--X_— X X k.k 1 %-. - k:. X.'X x X41 % X XX % - XC - - C"M^v - p 1MAX08. (� 21„ (14)ANCHORS `` MAX. O.C. PER JAMB (SEE t' { ■ SHEET 6 FOR J ■ :� CLUSTER O.C. SPACING) �."-'Re=i%:.= x -•ram%=%- Y r i'^ � x,-' ..X� 1 r" mil R i F* 6'6' MAX xxxl 24" MAX Imo— 8„ MAX TYP. L. _ C.L. ASTRAGAL IIInu41 191 1/2' MAX. �\ONV LYNAf 4 EXAMPLE OXXO ANCHORAGE PLAN Q� .•'' .IGENSF (4) PANEL, 48" x 108" DOOR FROM TABLE ON SHEET 4, ANCHOR TYPES 2 & 4 IN WOOD SUBSTRATE *No.58705_ to NO CHANGE THIS SHEET • (Ll •'. SiAi OF °ERM/AM/DADECOMMENTS 1ONOKOMINSOFL942R5� ANCHORAGESPACING&EXAMPLE PLANS %�(�s'•.!°CORIDA,.•''�C��� SERIES 770 H.P. ALUMINUM SGD - LMI °ER M/AM/ DADECOMMENTS P.O. eqx 45z3 I k' NOKOMIS. FL 34274U�nfak."�eve sack o..�w —. A LYNN MI LLER• P.E. SG0770H.P. NT$ 5 d 1D PGT0004 C P.EN58705 1" MIN. E.D. TYP. J EXT. 1/4" MAX SHIM aEXTERIOR INTERIOR - (ALL VERT. SECTIONS) 3.501, NOTE: ALL DIMENSIONS SHOWN 4.051" ARE BASED ON MINIMUM ! MIN. ALLOWED. 21/16" O.C. O.C. 2x WOOD BUCK TYP., SEE - ANCHOR NOTE 3, SHT. 1 TYPICAL JAMB CLUSTER FOR DETAILS "D" & "E" 1 3/8" MIN. SEE CHART, SHT.1 -�➢ I �— NOOD ANCHOR TYP., SEE 1/4' MAX. SHIM ANCHOR NOTE 2, SHT.1 1x WOOD REM FRAME HEAD _ -CKJYP .LATION SEE A NOTE 3,, SHT. 1 CONCRETE ANCHOR TYP., 4 1" MIN. SEE ANCHOR E.D. TYP. 21/16" O.C. NOTE 1, SHT. 1 EXT' 1 3/8" MIN. 1/4' r MAX. J 2x WOOD BUCK TYP., SEE SHIM ANCHOR NOTE 3, SHT. 1 WOOD ANCHOR TYP., SEE ANCHOR NOTE 2, SHT.1 DETAIL B. 2-TRACK FRAME HEAD WOOD INSTALLATION WOOD ANCHOR TYP., SEE 1 3/8" MIN. - r ANCHOR NOTE 2, SHT. 1 1/4"MAX. SHIM - 1/4" MAX (SEE ANCHOR NOTE 5, SHT. 1) 2x WOOD BUCK TYP., SEE ANCHOR NOTE 3, SHT. 1 - ------------------- INT ASTRAGAL OR INTERLOCK CENTERLINE j 7" MIN. 1.7 MIN, i I or N I I 2.04" o 3.50" MIN. 6 ANCHOR CLUSTER ----------------------------- INT. ASTRAGAL OR —INTERLOCK I CENTERLINE I I 1.75"MIN. 7" MIN. I I 1 o 2.04" I I 3.50" MIN. 8 ANCHOR CLUSTER Imo-INTERLOCKvR CENTERLINE f. SEE CHART, i 7" MIN. 3.50" SHT.1 MIN.....� o �+ +.:,: •: i o I =.••;_,; ; 21/16" O.C. _..... _4.051" CHART, SHT.1 1 x WOOD BUCKTYR, SEE ANCHOR EXT. NOTE 3, SHT.1 114" MAX SHIM 2 1I16" O.C. _m4 "'� `�° ''�. .• o: .; :: SEE CHART, arR • L SHT. 1 �r ►,elp "e CONCRETE ANCHOR TYP., SEE:ANCHOR.NOTE 1, SHT. 1 bETAIE F. 2-TRACK FRAME HEAD CONCRETEJNSTALLATION ,"7 ' 1/4" MAX i 1 21/16" O.C., TYP. _ I 21116" O.C. (SEE ANCHOR WOOD ANCHOR ��I TYP., SEE ANCHOR NOTE 5, S7-T . 1) EXT. r�. f1 3/8" MIN. NOTE 2, SHT. 1 �T• 1. MIN I 2x WOOD BUCK TYP., SEE 2 1/16" I F- ANCHOR NOTE 3, SHT. O.C., TYP. E.D. EXi - �,-,y_,,':. DETAIL E: 2 T C'C A AMEJAMB DETAIL C, 2-TRACK FRAME SILL rWOOD`INSTALL"ATIOR' CONCRETE ANCHOR TYP., WOOD INSTALLATION 1 SEE ANCHOR NOTE 1, SHT. t- ¢� /^-6 -- ll'G: R.neey. o"� C _ _CONCR J.J. 10/12/1 f C NO CHANGE THIS SHEET Q -- ➢ NOKOMIA FL 34275 P.O. BQX "2NOKOMIS, FL 34274 1" MIN E.D., TYP. SEE CHART, \\�JONY LYNN y SHT.1 �:.• OcENSF'•,/F,P SE CHART, _ No. 58705 TRACK FRAME S I CL> SHT, 1 LINSTALLATION ✓ _ �0 to /t XAMPLE CLUSTERS = C�•. Fr^rE I N.P. ALUMINUM SGD - LMI 11111fI11�1 NTS 6 m 10 PGT0004 C A LYNN MILLER, P.E. P.EN 58705 1► • PANEL LETTER /� SINGLE (� INTERLOCK SINGLE INTERLOCK LOCKS77LE AD %tA rL� LOCKSTILE SINGLE moxorl I INTERLOCK LRASTRAGAL __..-._ OUT DETAIL 'IV OR'L', SHT. 8 & ANCHOR OETAILS'D' & LOCKSTILE �'E, SHT. 6 fDETAIL'J', BHT.8 LOCKSTILE �� ' > I �- •'� ASTRAGAL DETAIL'M', SHT. 8 J v DETAIL T, SHT. 8 & SINGLE EXTERIOR ANCHOR DETAILS W, 'B' & INTERLOCK -P. SHT. 6 191 12" MAX. WIDTH SINGLE INTERLOCK 41" MAX SEE FIXED PANEL CLIP J ASTRAGAL D.L.O. DETAIL BELOW `(r/ D� WIDTH SINGLE INTERLOCK IV ASTRAGAL SINGLE qMPERLOCK CSINGLE ASTRAGAL INTERLOCK IN y (BQXINI P SINGLE 931 FDW INTERLOCK LOCKSTILE R FIXED SINGLE LOCKSTILE INTERLOCK TASTRAGAL FIXED (BOKOUT) OUT LOCKSTILE T AST R4GA1 FIXED INLOCKSTILE OR XPOT ASTRAGAL <BsSFIXED LOCKSTILE our SFIXED ASTRAGAL NOKW LOCKSTILE IN 4 INTERIOR (ALL PANEL TYPES) 15 EXTERIOR NOTE: REINFORCEMENT REQUIRED AT ALL INTERLOCKS. NO CHANGE THIS SHEET PANEL PANEL PANEL PANEL TYPE TYPE TYPE TYPE 'R' I 'L' 'D' I •P' SEE i REINF. I NOTE REINF. 3 9M7_7707-.10 AX. MAX D.L.O. HT HT. TYP TYP. SEE FRAME & OXXO (2 TRACK) DETAIL H', SHT. B & PANEL CORNER ANCHOR DETAILLS'C' & J CONSTRUCTION #8 X 1.00" #10 X 125" G', SHT. 6 DETAILS BELOW PH SMS (OPTIONAL) 1 TEK SCREW -'*-, 1� L #10 X 1.50"f If VIP' --XILG-UL-- PH SMS FIXED PANEL PANEL CORNER FRAME CORNER CLIP DETAIL DETAIL DETAIL HEAD SHOWN; APPLICABLE TO SILL NOTES: 1. SEE THIS SHEET FOR INDIVIDUAL PANEL CONFIGURATIONS. MAX NOMINAL PANEL WIDTH =48". SEE SHT, 8 FOR SECTION DETAILS AND SHTS.4-6 FOR ANCHORAGE DETAILS. 2. MAX. DLO WIDTH = 41" MAX. MAX. DLO HEIGHT = 97 718" MAX 3. (1) LOCK (ITEMS 75 & 107-110) AT EACH LOCKSTILE, LOCKING INTO KEEPER (ITEM 103) AT FRAME JAMB OR ASTRAGAL. NOKOMIS, 342,5 E PANEL TYPES/EXAMPLE ELEVATIONS NOKOM7oLoc 275 T� P.O.eQXlsw SERIES 770 H.P. ALUMINUM SGD - LMI NOKOMIS, a34274 ® SG N�-'J+ �% m 10 PGT0004 I C NOTE: 1. MAXIMUM NOMINAL PANEL WIDTH FOR ALL PANEL CONFIGURATIONS EQUALS 48" ru"ucr amViEw z wm 0. iico& �cwe Bob"Awe C ` �YNN 41/tjF/i, `�=•l��'\,\DENSE • . 'P 58705 a o,2-11 UJ E OF FLOR\OV, . zzz- I NAIL1� A LYNIG MI[l,�i,� P�E. P.E.055705 q. ALL REINFORCED INTERLOCK DETAIL'J' DETAIL'N' SCREEN AT HEAD PANEL CLIP HIS SHEET r- 4 INTERIOR (ALL HORIZ. SECTIONS) 15 EXTERIOR 15 103 0112 113 106 105 S2 40 DETAIL'L' ASTRAGAL DETAIL'M' AT MIDSPAN � 61 3" DETAIL'K' (FIXED PANEL) 0 069 } DETAIL'P'SCREEN y 0 f21 ATJAMB DETAIL'OSCREEN 9l16• AT SILL FIXED PANEL CLIP REO'D AT TOP (HEAD) & BOTTOM (SILL) OF FIXED "O" EXTERIOR INTERIOR,_I�, PANELS. SEE SECTION •J• THIS SHT. & SILL RISERS OPTIONS {ALL VERT. SECTIONS} FIXED PANEL CLIP DETAIL ON SHT. 7 (SEE D.P. LIMIT TABLE 1A, SHEET 4) 24 23 z1 1s a.oss• 2.555' 5• tsar FLUSH BOX SILL RISER LOW BOX SILL RISER MEDIUM BOX SILL RISER HIGH BOX SILL RISER 25 22 18 20 —f 3.305' 4.055• 1.58r 2.555° FLUSH FLAT SILL RISER LOW FLAT SILL RISER MEDIUM FLAT SILL RISER HIGH FLAT SILL RISER er. am aaw�e waaya:c :J. fOHT/11 C NOCHANGE THISSNEET ar ° VERTIC. pO1"� 7070TECHNOLOGYORIVE M OW3110 B PER MUIMI DADECOMMENTS NOKOMS FL 90275 m ar °°� "°" SERIES MC if/16/09 A PER P.o.90X762B 7 u�M_,__ cnaeaa a„s NCKCMIS, FL 34274 ,,, 9771W MAX DETAILT DLO TYR DETAIL'H' HORIZONTAL I N.P. ALUMINUM SGD - LMI ak sue rm NTS 1 8 d 10 Q+.tioPGT0004 e�auCr atcvel;� WO6 No. 58705 NIA OF FCOR10p`.-''Q) SS/o' /NAL �? 0. LYNNiY(I K P.E. P.E.$ M705 4- fli 1.303" 1.050" 18" 0.7� 0.8° �0.752 " .0.290" 1.0031050" 5" 0.06�0.779. 1" 0,757"0.-40.080° 0.050` 0.050"0 INTERLOCK SCREW COVER FRAME SCREW COVER GLAZING BEAD (SINGLE) GLAZING BEAD (I.G.) (65) MATL: 6063-T6 (5) MAIL: 6063-T6 (78) MATL: 6063 T6 SILL TRACK (79) MATL: (105)MATL: 8063 T6 8063 T6 FIXED PANEL CLIP 4.125" 6198° -- MATL: 6063 T6 4.49" Lli0.062" E: 1.304" 1 � r 1.211" 1.505" I O.OB1" F� 3.25" 2 TRACK HEAD .0 SCREEN TRACK 1 m--, 0.01 0" 2-TRACK SILL TOPIBOTTOM BOTTOM RAIL (2) MATL: 6063-T6 0.232' (7) MATL: 6063-T6 (69) MArL:6063.T6 3.979' 0.075' 0.062"1.505" 0.133" 16' 1.645" FLUSH FLAT SILL RISER (18) MATL: 6063-T6 3 125" 0.0802-TRACK SILL W/ SCREEN TRACK 0.281" (8) MATL: 6063-T6 HEAVY DUTY STILE HEAVY DUTY ASTRAGAL (61) MATL:8063-T6 (68) MATL: 6063-TS 5.069" kp .654"1.211"0.080" 1.2 2-TRACK HEAD (1) MATL: 6063-T6 0.25O' 0.750" REINFORCEMENT 86 MAll 6063-TO 0.750" A EL L 762" ENGTH - 91 0.062" 0.062" 1.019" SCREEN STILEI 0 062" (40) MATL: 6063-T8 1.045" 1.162" 1.888" �" 1.993" 0.062" LU 0.875" 1.739' SCREEN TOP RAIL I INTERLOCK (45) MATL' 6063-T6 (62) MATL• 6663-T8 •�j 1.36" 0.081" 5.069` 2-TRACK JAMB (14)MATL• 6083-T6 ]_ _J �� " 0.080" -j Fes-- 0.5F 1.993" 0.232" Tl 0.062' SCREEN BTM. RAIL 0.232" 0.750° (46) MATL: 6063-T6 0232" 4.055 0.062" jam-- ►)- 0.906' 3.955° 3.305" I I 3.205" 2.555" � 2.455' 0.062" j .l 1.567" HIGH BOX S -' j 0.062" -�I 0.062" �Ir+ 0.062' ILL RISER MEDIUM BOX SILL RISER LOW BOX SILL RISER FLUSH BOX SILL RISER LOW FLAT SILL RISER MED. FLAT SILL RISER HIGH FLAT SILL RISER (24) MATL: 6063-T6 (23) MATL:6063T6 (21) MATL-. 6063-TB (19) MATL: 6063-T6 (20) MATL: 6063-T6 (22) MATL: 6063-TG (25) MATL: 6063 T6 107ECHNOLOOYDRIW NOKOMIS, FL 34275 P.O. 8OX law NOXOMIS FL 34274 770 H.P. ALUMINUM SGD - LMI smc s� o"eppw NTS 10 a 10 PG70004 1.36" 0.081" 6.198" 2-TRACK JAMB W/ SCREEN TRACK (15) MATL: 6063-T6 PYm0Citpavi 8® �unurrl,, NY LYNN Qom; •' \,%CENS?j*-.,ccp * N0.58705 * - STA OF !L /ONtA1'L1 _EN.��. A LYFPIIMIL' , P.E. P.F-# 58705 _7l Florida Building Code Online Page T of 3 BCIS Home Log In ' User Hot Topics ! Submit Surcharge I Stats & Facts Publications I FBC Staff ! BCIS Site Map Links ' Search l Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL, 9- Application Type Revision Code Version i Application Status Approved 4 *Approved by DCA. Approvals by DCA shall be reviewed and s' ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer j PGT Indu tt irsrw Address/Phone/Email '07� ology Drive Nokomis, FL 34275 (941)486-0100 Ext22318 druark@pgtindustries.com Authorized Signature ]ens Rosowski jrosowski@pgtindustries.com Technical Representative ]ens Rosowski Address/Phone/Email 1070 Technology Drive Nokomis, FL 34275 (941)486-0100 Ext21140 jrosowski@pgtindustries.com Quality Assurance Representative Address/Phone/Email I Category Windows Subcategory M1 iSingle Hung Compliance Method Certification Mark or Listing Certification Agency Miami -Dade BCCO - CER Validated By �9 Miami -Dade BCCO - VAL S Referenced Standard and Year (of Standard) Standard Year TAS 201, 202, 203 1994 TAS 202 1994 Equivalence of Product Sindards Certified By h 1� d Product Approval Method Method 1 Option A 1 http://www.floridabuilding.org/pr/pi app dtl.aspx?param=wGEVXQwtDquSlBu8CAEm... 11/5/2012 Florida Building Code Online 4 �) Page 2 of 3 Date Submitted 06/06/2012 Date Validated 06/07/2012 Date Pending FBC Approval Date Approved 06/11/2012 ummary of Products FL # hyodel, Number or Name Description 239.1 SH - 200 (Non -Impact) JjAlumlnurn Single Hung Window Limits of Use Certification Agency Certificate Approved for use in HlVHZ: Yes FL239 R18 C CAC 11-1013.12.pdf Approved for use out°ide HVHZ: Yes Quality Assurance Contract Expiration Date I Impact Resistant: No 09/01/2016 Design Pressure: N/A, Installation Instructions Other: Please see Miami -Dade County Notice of FL239_R1$_iT 11.-1013.._12,pdf Acceptance (NOA) for prpduct performance information, Verified By: Miami -Dade BCCO - CER anchorage details, and achor type, size, and spacing Created by Independent Third Party: information. Evaluation Reports Created by Independent Third Party: 239.2 - 500 (Large Missile Impact) WinGuard Vinyl Single Hung Window Limits of Use Certification Agency Certificate Approved for use in HI1/HZ: Yes FL239 R18 C CAC 11-1013.19.pdf Approved for use out ide HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Ye 01/08/2014 Design Pressure: N/A Installation Instructions Other: Please see Mia i-Dade County Notice of FL239_RS£ II_11.-_10.13 19..pi f Acceptance (NOA) for prRduct performance information, Verified By: Miami -Dade BCCO - CER anchorage details, and a'' chor type, size, and spacing Created by Independent Third Party: information. 0 Evaluation Reports III Created by Independent Third Party: 239.3 JSJI - 600 (Non -Impact) lAluminurn Single Hung Window Limits of Use Certification Agency Certificate Approved for use in KZ: Yes FL239 R18 C CAC 11-1013.13.odf Approved for use ouisoide HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 01/26/2016 Design Pressure: N/A Installation Instructions Other: Please see Mia i-Dade County Notice of FL239 R18 11 11-1013.13.pdf Acceptance (NOA) for pr duct performance information, Verified By: Miami -Dade BCCO - CER anchorage details, and a' chor type, size, and spacing Created by Independent Third Party: information. Evaluation Reports Created by Independent Third Party: 239.4 - 700 (Impact) jjWlnGuard Aluminum Single Hung Window Limits of Use Certification Agency Certificate Approved for use in VHZ: Yes FL239 RIB C CAC 11-1013.14.ndf Approved for use out id.HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Ye . 03/26/2016 Design Pressure: N/A Installation Instructions Other: Please see Miami -Dade County Notice of FL239 R18 II 11-1013.14.pdf Acceptance (NOA) for product performance information, Verified By: Miami -Dade BCCO - CER anchorage details, and aPchor type, size, and spacing Created by Independent Third Party: information. Evaluation Reports l Created by Independent Third Party: 239.5 -- 800 (Large Missile,Impact) Multi -Story Aluminum Single Hung Window Limits of Use Certification Agency Certificate Approved for use in VHZ: Yes FL239 R18 C CAC 11-1222.04 Lhl.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 05/03/2017 Design Pressure: N/A Installation Instructions Other: Please see Mia ]-Dade County Notice of FL239 R18 II 11-1222.04 LM.odf Acceptance (NOA) for pr duct performance information, Verified By: Miami -Dade BCCO -CER anchorage details, and a chor type, size, and spacing Created by Independent Third Party: information. Evaluation Reports Created by Independent Third Party: 239.6 I - 800 (Small Missile Impact) Multi -Story Aluminum Single Hung Window Limits of Use Certification Agency Certificate Approved for use In HZ: Yes FL239 RISC CAC 11-1.222.05 SM.pdf Approved for use out'ide HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Ye 05/03/2017 Design Pressure: N/A Installation Instructions Other: Please see Mia i-Dade County Notice of FL239 R18 II 11-1222.05 SM.odf http://www.floridabuilding.org/pr/p�'_app_dtl.aspx?param=wGEVXQwtDquS lBu8CAEm... 11/5/2012 e Florida Building Code Online Page 3 of 3 Acceptance (NOA) for pr duct performance Information, Verified By: Miami -Dade BCCO - CER anchorage details, and a chor type, size, and spacing Created by Independent Third Party: information. Evaluation Reports Created by Independent Third Party: 239.7 ri7-3000 (Large Missile Impact) IlArchitectural Systems Aluminum Single Hung Window Limits of Use Certification Agency Certificate Approved for use in HZ: Yes FL239 R18 C CAC 11-1013.18.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 12/06/2012 Design Pressure: N/A, Installation Instructions Other: Please see Miami -Dade County Notice of FL239 R18 II 11-1013.18,pdf Acceptance (NOA) for product performance Information, Verified By: Miami -Dade BCCO - CER anchorage details, and anchor type, size, and spacing Created by Independent Third Party: Information. ) Evaluation Reports f Created by Independent Third Party: 239.8 SH-3000 (Small Missile Impact) IlArchitectural Systems Aluminum Single Hung Window Limits of Use Certification Agency Certificate Approved for use in 11VHZ: Yes FL239 R18 C CAC 11-1013.17.pdf Approved for use out$lde HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 12/06/2012 Design Pressure: N/A; Installation Instructions Other: Please see Mia i-Dade County Notice of FL239 R18 II 11_1013.17.pf Acceptance (NOA) for pr duct performance information, Verified By: Miami -Dade BCCO - CER anchorage details, and anchor type, size, and spacing Created by Independent Third Party: information. Evaluation Reports Created by Independent Third Party: V Back Next t• Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/E employer. Copyright 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement Refund Statement Under Florida law, email addre ses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(2), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they haq one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to su{ply a personal address, please provide the Department with an email address which can be made available to the public. dj To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: _ ® fir, 0 ;:E:4:ltY{ 'at6rltrt�r 4 A http://www.floridabuilding.org/pr/p app_dtl.aspx?param=wGEVXQwtDquSlBu8CAEm... 11/5/2012 l I MIAMI• MIAMI-DADE COUNTY, FLORIDA MCAUUM• PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING, ENV RONMENT, AND REGULATORY 11805 SW 26 Street, Room 208 AFFAIRS (PERA) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATIO DIVISION T (786) 315 2590 F (786) 315-2599 NOTICE OF ACCEPTAN E (NOA) www.miumidade.gov/pera/ PGT Industries, Inc. 1070 Technology Drive North Venice, FL 34275 y SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami --Dade County PERA- Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). ; This NOA shall not be valid after the, expiration date stated below. The Miami -Dade County Product Control Section (In Miami -Dade County) an . /or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, thmanufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or susond the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material r iiis to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurrica „ Zone. _ DESCRIPTION: Series "SE- 800"�AI<`umirium Single Iiurig,Wndow S1M.I. APPROVAL DOCUMENT: Drawing No. NED-SH800SM-01, titled "SH Window -Small Missile", sheets 1 through 7 of 7, dated 11/11/11 with the latest revision dated 04/19/12, prepared by manufacture, signed and sealed by A. Lynn Miller, P. E., be+ng the Miami -Dade County Product Control Approval stamp with the Notice of Acceptance number and Approval date -by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING-Small� fissile Impact"Resistan_1: LABELING: Each unit shall be a permanent label with the manufacturer's name or logo, city, state, model/ series and following statem t: "Miami -Dade County Product Control Approved" unless otherwise noted herein. RENEWAL of this NOA shall be onsidered after a renewal application has been filed and there has been no change in the applicable building ode negatively affecting the performance of this product. TERMINATION of this NOA willi occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufaclture of the product or process. Misuse of this NOA as .an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA- shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date ma? be displayed in advertising literature. If any :portion of the NOA is displayed, then it shall be done in its [entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available fo , inspection at the job site at the request of the Building Official. This NOA consists of this page 1, Ividence pages E-1 and E 2, as well as approval document mentioned above. The submitted documentation was rtiewed by Jaime D. Gascon, P. E. NOA No.11-1222.05 MIAMI•DADE COUNTY -- at 9-�%4 v Expiration Date: ,May°03;,2017 +� 1� Approval Date: ~ May 03, 2012 0 Page 1 1 n PGT Industries, Inc. A. DRAWINGS 4 1. Manufacturer's dieadrawings and sections.. 2. Drawing No. Mb—SH800SM-01, titled "SH Window —Small Missile", sheets 1 through 7 of 7, dated 11/11/11 with the latest revision dated 04/19/12, prepared by manufacture, sign.0 and sealed by A. Lynn Miller, P. E. B. TESTS 1. Test reports on: 1)i Air Infiltration Test, per FBC, TAS 202--94 2)", Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test w/ and w/o screen, per FBC., TAS 202-94, per ASTM E 547-00 and per ASTM E 331-00 4)1 Small Missile Impact Test per FBC, TAS 201-94 5)Cyclic Wind Pressure Loading per FBC, TAS 20344 69 Forced Entry Test, Type "A —A" vertical sliding window, per FBC 2411 3.2.1, TAS 202-94, per AAMA 1302.5-02 and per ASTM F 588-04 7). ) Standard Test Methods for Deglazing Force of Fenestration I Products per ASTM E 987-88 (2009) 8)1 Standard Test Method for Determination of Operating Force of i vertical sliding windows per ASTM E 2068-00 (2008) m along with arketup drawings and installation diagram of Aluminum single hung window, prepared; by Fenestration Testing Laboratory, Inc., Test Report No. FTL-6642, dated j0/03/11, signed and sealed by Marlin D. Brinson, P. E. C. CALCULATIONS } 1. Anchor verificatio# calculations and structural analysis, complying with FBC-2010, dated 12/16/11, prppared by manufacture, with the latest revision, dated 04/09/12, signed and sealed by A. Lynn Miller, P. E. 2. Glazing complies with ASTM E1300- 04 D. QUALITY ASSURANC 1. Miami —Dade Dep irtment of Permitting, Environment, and Regulatory Affairs (PERA). 2 E. MATERIAL CERTIFICATIONS 1. Notice of Accep ce No. 11-0624.01 issued to E.I. DuPont DeNemours & Co., Inc. for their "DuPont Butacite® PVB Interlayer" dated 09/08/2011, expiring on 12/11/2016. + Jaime D. Gascon, P. E. Product Control Section Supervisor A NOA No. 11 1222.05 Expiration Date: May 03, 2017 E-1 Approval Date: May 03, 2012 � PGT Industries, Inc. E. STATEMENTS 1. Statement letter ofi compliance with the FBC 2007 and FBC-2010, dated 12/16/11, signed and sealed by A. Lynn Miller, P. E. 2. Statement letter of no financial interest and conformance, dated 12/16/11, signed and sealed by A. Lynn Miller., P. E. 3. Laboratory compliance letter for Test Report No. FT1,6642, issued by Fenestration Testing Laborato, Inc., dated 10/03/11, signed and sealed by Marlin D. Brinson, P. E. 4. Proposal No. 11-0795—R issued by Product Control, dated August 10, 2011, signed by Manuel Perez, 1. E. F. OTHERS 1. None. Jaime D. Gascon, P. E. Product Control Section Supervisor NOA No.11-1222.05 Expiration Date: May 03, 2017 Approval Date: May 03, 2012 E-2 GENERAL NOTES: 800 SERIES SMALL MISSILE IMPACT RESISTANT SINGLE HUNG WINDOW 1) THIS PRODUCT HAS BEEN DESIGNED & TESTED TO COMPLY WITH THE REQUIREMENTS OF THE 2010 FLORIDA BUILDING CODE, INCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ). 2) MIAMI-DADE COUNTY APPROVED SHUTTERS ARE REQUIRED AT INSTALLATIONS BELOW 30 FT (NONE REQUIRED AT INSTALLATIONS ABOVE 30 FT). 3) FOR MASONRY APPLICATIONS IN MIAMI-DADE COUNTY, USE ONLY MIAMI-DADE COUNTY APPROVED MASONRY ANCHORS. MATERIALS USED FOR ANCHOR EVALUATIONS WERE SOUTHERN PINE, ASTM C9D CONCRETE MASONRY UNITS AND CONCRETE WITH MIN. KSI PER ANCHOR TYPE, SEE TABLES 2,4 OR 6. 4) ALL WOOD BUCKS LESS THAN 1-1/2' THICK ARE TO BE CONSIDERED 1X INSTALLATIONS. 1X WOOD BUCKS ARE OPTIONAL IF UNIT IS INSTALLED DIRECTLY TO SUBSTRATE. WOOD BUCKS DEPICTED AS 2X ARE 1-12' THICK OR GREATER. IX AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED TO E4AS PROPERLY TRANSFER LOADS TO THE STRUCTURE. WOOD BUCK DESIGN AND AN INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF 1. 3 & 6 5) ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. USE ANCHORS OF SUFFICIENT LENGTH AS SPECIFIED ON TABLES 2.4 OR 6. NARROW JOINT SEALANT IS USED ON ALL FOUR A, SEE CORNERS OF THE FRAME. OVERALL SEAUNGIFLASHING STRATEGY FOR SHEET 2 WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS AND IS BEYOND THE SCOPE OF THESE INSTRUCTIONS. EQUALLY 6) 1/4- MAX SHIMS ARE REQUIRED AT EACH ANCHOR LOCATION WHERE THE SPACED PRODUCT IS NOT FLUSH TO THE SUBSTRATE. USE SHIMS CAPABLE OF ANCHORS TRANSFERRING APPLIED LOADS. PER TABLES 1,3&5 7)DESIGN PRESSURES: A. NEGATIVE DESIGN LOADS BASED ON STRUCTURAL & CYCLE TESTING AND GLASS PER ASTM E1300-04. ( B. POSITIVE DESIGN LOADS BASED ON WATER TEST PRESSURE, STRUCTURAL , & CYCLE TESTING AND GLASS PER ASTM E130D-04. SEE SILL WEEP- rl NOTCH DETAILS J B) THE ANCHORAGE METHODS SHOWN HAVE BEEN DESIGNED TO RESIST THE SHEET 7OF7 WINDLOADS CORRESPONDING TO THE REQUIRED DESIGN PRESSURE. THE 33-1/3% STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT. THE 1.6 LOAD DURATION FACTOR WAS USED FOR THE EVALUATION 63-1/8" MAX. WINDOW WIDTH — 52-1/8' BUCK WIDTH — 49-518" VISIBLE LIGHT 1 B-12' MAX �� -CS _ IT 2 10" MAX / A, SEE 35.3N6" SHEET2 VISIBLE LIGHT B. SEE 48.1/4SHEET2 ~ VISIBLE LIGHT — NO ANCHORS IN FRAME SILL 7r BUCK 10" HEIGHT 78- MIgX, I MAX. WINDOW �35.3116" HEIGHT VISIBLE LIGHT _1 1 OF ANCHORS INTO WOOD. ANCHORS THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE FLORIDA IT,YR:=EQIfAL=CITE BUILDING CODE FOR CORROSION RESISTANCE. FRA" ME'E_LE_V_ 9) REFERENCES: TEST REPORTS FTL-0643; ELCO ULTRACON NON ELCO _AT_ION CRETEFLEX NOA; ANSIIAF&PA NDS FOR WOOD CONSTRUCTION AND ADM ALUMINUM DESIGN MANUAL Jr1GC 1 INUCA: GENERAL NOTES ...................... 1 ELEVATIONS..................._......_... 1 DESIGN PRESSURES..................1 INSTALLATION ..... ..................... 2 ANCHOR QUANTITIES 0.......__. 3 ANCHOR QUANTITIES B.......... _ 4 ANCHOR QUANTITIES C._...._....5- EXTRUSION PROFILES ............ ... 6' PARTS LIST .................. ......... _...... 6, GLAZING DETAILS .......... _........... 6' ASSEMBLY DETAILS ......... ....... _ 7 Maximum Anchor Spacing, As lealed, EqueHite Header 16.125 Aboye MR 24.58 Below MR 13,71 6' MAX ``��111111111/� ���d'�N��CENSB �'•�� �� (4o. 56705 ;o W_ S TA E `•. P PLORV / / Sl IOINA� ` A. LYNN MaER%, RE P.E.0 5871Z DESIGN PRESSURE RATING IMPACT RATING r��` 90:Oi=160.0 YSMALLMISSILE1NIPAar RESISTANT;. Fok'ALCSIZES, CONFIGURATIONS ANDAtTYPES 53.1/8" MAX. WINDOW WIDTH 52-1/8' BUCK WIDTH — 495/8' VISIBLE LIGHT -+ 18-112. MAX B. SEE SHEET2 EQUALLY SPACED / PER TABLES I 1,3&5 1 / I I A, SEE SHEET2 Irl L EQUALLY .i .� SPACED ANCHORS - / / PER TABLES 1,3&5 SEE SILL WEEP - NOTCH DETAILS SHEET 7OF7 1070 TECHNOLOGY DRIVE N. VENICE. FL 34275 P.O. BOX 1529 NOKOMIS.' FL 34274 CERr. OF AUTH. #29296 L _,B, SEE SHEET 48-1/4' �— VISIBLE LIGHT —� NO ANCHORS IN FRAME SILL 10' MAX 54-I 18' VISIBLE SHEET2 77' l BUCK �'- __. 1 HEIGHT 78• -��- MAX WINDOW HEIGHT 'IMAX. 15.314' VISIBLE LIGHT 6" MAX. TYP. PROVIEW / ORIEL FRAME ELEVATION Maximum Anchor Spacing, As tested, PmView Header 16.125 Above MR 22.03 Below MR 13.95 ReWeed W. Dale: ReWeian: ReWaed Ur. Data ReWeloa DeaertPDon: GENERAL NOTES & ELEVATIONS T(ae: SH WINDOW -SMALL MISSILE Serres/Madeh SWIM Shoe - SH-800 NTS 1 OF 7 11/11/11 INSTALLATION OPTION 1 INSTALLATION INTO 2X WOOD BUCKSTRIP, SEE WOOD 2X, SEE NOTE 2, NOTE 2, THIS SHEET. 2X WOOD. THIS SHEET. EDGE DISTANCSEE NOTE 2, THIS SHEET. OPTIONAL ADDON FLANGE @ HEAD, 62 SILL & JAMBS U EMSEl1MENT -1/4' MAX. SHIM INSTALLATION OPTION 2 INSTALLATION EMBEDMENT ANCHORS DIRECTLY INTO MASONRY. (ABOVE MEETING -� '1/4' MAX. SHIM RAIL SHOWN) EDGE ° 3 DISTANCE A .. OPT. 79 TYP. ANCHOR TYPE, EXTERIOR FIXED VISIBLE TYP. ANCHOR TYPE, EMBEDMENT AND EDGE j 51 EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE, DISTANCE PER SUBSTRATE, SEE TABLES 2, 4 OR 6. , a LIGHT SEE TABLES 2, 4OR 6. HEIGHT I 61 5 45 16 OPTIONAL ADDON 20 15 FLANGE @ HEAD, 62 —.21 7 SILL & JAMBS BUCK HEIGHT HEIGHT J MUM SASH VISIBLE LIGHT HEIGHT SEE SILL WEEP - NOTCH DETAILS — SHEET 7 OF 7 USE EITHER TOP SWEEP LATCH(p21) OR SILL LOCK (0). — NO ANCHORS IN FRAME SILL Z f 1 LIM. MAX. SHIM 1X WOOD BUCKSTRIP. SEE NOTE 2 THIS SHEET. ,. • . ;^ .. TYP. SMS (GS), SEE TABLES 2 OR 4. INSTALLATION OPTION 4 INSTALLATION ANCHORS DIRECTLY INTO METAL. 1/4'MAX.SHIM 1X WOOD BUCKSTRIP, SEE NOTE 2, THIS SHEET. CONCRETE/CMLI PERANCHOR REQUIREMENT INSTALLATION OPTION 3 INSTALLATION ANCHORS THROUGH 1X BUCKSTRIP INTO MASONRY. 1/4' MAX. SHIM b < (BELOW MEETING J RAIL SHOWN) 12 3 BALANCE TYPE VARIES WITH SASH EMBEDMENT WEIGHT 43 50 EDGE 49 DISTANCE SASH VISIBLE-- ---, - II'� FIXED VISIBLE LIGHT WIDTH LIGHT WIDTH 7 BUCK WIDTH WINDOW WIDTH HORIZONTAL SECTION:A=A`�i TYPE VARIES WITH SASH WEIGHT — 'b—1 EXTERIOR DADE APPROVED MULLION, V ALUMINUM, STEEL FRAMING OR STEEL STUD. SEE SUBSTRATE PROPERTIES, TABLES 2 OR 4. 1 0111111r \�YNN 4414 poSe 140.55705 ' � •• STA F . O(�� •.. FLORID.-** A. L4hPhl R. P.E. NOTES —2- EXTERIOR �� TYP. ANCHOR TYPE, EMBEDMENT AND EDGE 15 DISTANCE PER SUBSTRATE, SEE TABLES 2,4 OR 6. JAMB ANCHORS BELOW THE MEETING RAIL MUST NOT INTERFERE WITH THE • OPERATION OF THE SASH. 1) USE ONLY SUBSTRATE -APPROPRIATE ANCHORS LISTED ON TABLES 2.4 OR 6. FOLLOW EMBEDMENT AND EDGE DISTANCE LIMITS. ANY INSTALLATION OPTION SHOWN MAY BE USED ON ANY SIDE OF THE WINDOW. 2)ALL WOOD BUCKS LESS THAN 1-1/2'THICK ARE TO BE CONSIDERED 1X INSTALLATIONS. 1X WOOD BUCKS ARE OPTIONAL IF UNIT IS INSTALLED DIRECTLY TO SUBSTRATE. WOOD BUCKS DEPICTED AS 2X ARE 1-1/2' THICK OR GREATER 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED TO PROPERLY TRANSFER LOADS TO THE STRUCTURE. WOOD BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD. Forl pe• ;, jb�3j?��2, 'TI�e Res(sed tJy: Dote: Revision; ReAsed Ey: Dote: Nt'-J•_ 7— I-;i°..,'•;:o Y... �7_ Revktan: QDr'].� DeseripDan: Drawn or. FLANGE FRAME INSTALLATION DETAILS J ROSOWSKI 1070 TECHNOLOGY DRIVE TWe: Dat; N. , FL SH WINDOW -SMALL MISSILE 11/11/11 P.O. BOX 1529 P.O. 29 NOKOMIS.* FL 34274 Series/Modeh Seale: Shoot: Drawing No. Rev. CERT. OF AM. #29296 SH-800 NTS 1 2 OF 7 MD-SH800SM-01 TARLF 1_• ANCHOR QUANTITIES REQUIRED -Group A Anchors Sash Height Or Height Range ,_ve raH-W ad ow Width 19.1/8" 26-1/2' 33" (' RW3_Tj_j1 3 41- 45' 49' 53-1/8' Jamb ` �_ Jamb Jamb Jamb gS Jamb R Jamb 9 Jamh Jarnh m ¢ m ¢ m ¢ m ¢ m ¢ a m ¢ m r ¢ m ¢ m 24.11T 12.314' (Equai-Lile) 1 2 1 1 2 1 1 2 1 1 2 1 1 2 2 1 2 2 1 2 2 1 2 2 25-112' 13-1/4" (EqueFUle) 1 2 1 1 2- 1 1 2 1 1 2 2 1 2 2 1 2 2 1 2 2 1 3 2 37' 19' (Equal-Ute) 2 2 1 2 2 1 2 2 2 2 3 2 2 3 2 2 3 2 2 3 3 2 4 3 19.5/8' (Equal-Ule) 2 2 1 2 2 1 2 2 2 2 3 2 2 3 2 2 3 2 2. 3 3 2 4 3 3&3/8" 19' thm 10-9/16" 2 2 1 2 2 1 2 2- 2 2 3 2 2 3 2 2 3 2 2 3 3 2 4 3 16" lhiu 18.191E • 2 2 1 2 2 1 2 2 2 2 3 2 2 3 2 2 3 3 2 3 3 3 4 3 13' thar _-.151a6 2 2 1 2 2 1 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 3 3 4 "c�23u�Egualytej 2 2 1 2 2 1 2 3 2 2 3 2 2 3 2 2 4 3 2 4 3 2 4 3 (y----�� d 2Z' Uvu 22-15116' 2 2 1 2 2 1 2 3 2 2 3 2 2 3 2 2 4 3 2 4 3 3 4 3 tldm4l•13H6r , A•y u..,. Y2;� ._:J - _ Ir -IF 16' thm 18-15116" 2 2 1 2 2 1 2 2 2 3 3 2 3 3 3 3 3 3 3 3 3 3 .4 4 13' Ihm 15-15/16- 2 2 1 2 2 1 3 2 2 3 2 2 3 3 3 3 3 3 3 3 4 4 3 4 25314' (Equal•Ule) 2 3 1 2 3 1 2 3 2 2 3 2 2 4 3 3 4 3 3 4 3 3 5 3 25' lhm 25-11116' 2 3 1 2 3 1 2 3 2 2 3 2 2 4 3 3 4 3 3 4 3 3 5 3 8, 2T thm24.16116' 2 3 1 2 3 1 2 3 2 3 3 2 3 4 3 3 4 3 3 4 3 3 5 4 19" thm 21-15116' s 2 2 1 2 2 1 3 3 2 3 3 2 3 3 3 3 4 3 3 4 4 4 4 4 18" Ihm 18.1916' 2 2 1 3 2 1 3 2 2 3 3 2 3 3 3 4 3 3 4 3 4 4 4 4 13'thm 15-191E 2 2 1 3 2 1 3 2 2 4 2 2 4 3 3 4 3 3 4. 3 4 4 3 4 ZD 32" (Equal-Ule) 2 3 1 2 3 1 3 4 2 3 4 2 3 4 3 3 5 3 3 5 4 4 6 4 } 31" Bum 31.15116' 2 3 1 2 3 1 3 4 2 3 4 2 3 4 3 3 5 3 3 5 4 4 6 4 288' Ihm 30.15116' 2 3 1 3 3 1 3 4 2 3 4 2 3 4 3 4 5 3 4 5 4 4 6 4 }� 63. 25" thm 27-15118" • 2 3 1 3 3 1 3 3 2 4 4 2 4 4 3 4 4 3 4 5 4 4 5 4 2T thm 24-15/1G 3 3 1 3 3 1 4 3 2 4 3 2 4 4 3 4 4 3 5 4 4 5 5 4 v19' thin 21-191E 3 2 1 3 2 1 4 3 2 4 3 2 4 3 3 5 4 3 5 4 4 5 4 5 0 161 thin 18-16116' 3 2 1 4 2 1 4 2 2 5 3 2 5 3 3 5 3 3 5 3 4 6 4 5 13' thm 15.15/1S' 3 2 -1 4 2 1 4 2 2 5 2 2 5 3 3 6 3 3 8 3 4 6 3 5 37" (Equal-Ule) 2 3 1 3 3 1 3 4 2 3 5 2 4 5 3 4 6 3 4 6 4 4 6 4 34• thm 36-15/16" 3 3 1 3 3 1 3 4 1 2 4 5 2 4 5 3 4 6 3 4 6 4 5 e 4 31" thm 33.1916' 3 3 1 3 3 1 4 4 2 4 4 2 4 5 3 5 5 3 5 6 4 5 6 4 73" 2E thm 30.191E •- 3 3 1 3 3 1 4 4 2 4 4 2 5 4 3 5 5 3 5 5 4 5 6 5 25" lhm 27-191E 3 3 1 4 3 1 4 3 2 5 4 2 5 4 3 5 4 3 6 5 4 6 5 5 2V thm 24-191E 3 3 1 4 3 1 5 3 2 5 3 2 5 4 3 6 4 3 6 4 4 6 5 5 19' Ihru 21-1918' 3 2 1 4 2 1 5 3 2 5 3 2 6 3 3 8 4 3 8 4 4 7 4 5 Is' thin 18.15116" 3 2 1 4 2 1 5 2 2 6 3 2 6 3 1 3 T 1 3 1 3 7 3 4 7 4 5 39.112' (Equal-Ute) 1 2 3 1 3 4 1 3 4 2 4 5 2 4 5 3 4 6 3 4 1 6 4 5 7 4 37" thm 39.711E 1 3 3 1 3 4 1 4 4 2 4 5 2 4 5 3 4 6 3 5 8 4 5 7 4 34'thm 36-1916' 3 3 1 3 3 1 4 4 2 4 5 2 4 5 3 6 8 3 5 6 4 5 8 5 78" 31" thm 33.191E ♦ 3 3 1 4 3 1 4 4 2 5 4 2 5 5 3 5 5 3 5 8 4 8 6 5 2W thm 30.191E 3 3 1 4 3 1 4 4 2 5 4 2 5 4 3 6 5 3 6 5 4 6 6 5 25' Ihm 27-1918' 3 3 5 3 2 5 4 2 8 4 3 6 4 3 8 5 4 7 5 5 22• thm 24-15116" 3 3 H 5 3 2 6 3 2 8 4 3 6 4 3 7 4 4 7 5 5 20" thru 21.1916" 3 2 5 3 2 8 3 2 8 3 3 7 4 3 7 4 4 7 4 1 5 • SASH HEIGHT RANGE INCLUDES THE STANDARD PROVIEW /ORIEL CONFIGURATION. TARI F 9- Anchor Anchor Substrate Min. Edge Min. Embedment Group Distance P.T. Southem Pine (SG = .55) 9/16" 1-318" 012. SIeeI SMS (GS) 6063-75 Alum 3l8" 118• •• or 012, 410 SS SMS Steel Stud, Gr. 33 min. 318" 0.045 (18 Go) •♦ A36 Steel 318" 1/8" •♦ A Concrete (min. 2.7 ksn 2-112" 1-314" 3/t6" Steel Ullmcon Greuled•filled Block, (ASTM C90) 2.112" 2-1/4" Conemle (min. 2.7 ksi) 1' 114' Steel Ultracon Hollow Block, (AS7M C90) 2-1/2' 1-1l4" •• MIMIMUM OF 3 THREADS BEYOND THE METAL SUBSTRATE. FIGURE A: SASH -•�-� _� •ORGSS---- SECTION (WITH INSULATED GLASS) T SASH VISIBLE LIGHT HEIGHT L NOTES: 1) FOR BUCK DIMENSIONS, SUBTRACT 1• 2)'MR' ='MEETING RAIL" _ 3) FOR OVERALL SASH WIDTH, SUBTRACT 2-9/16" FROM THE WINDOW WIDTH. 4) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION SHOWN ON THE SASH TABLE. HEIGHT, 5) SEE SHEET 2 FOR INSTALLATION 39-1/2'MAX. DETAILS. 1070 TECHNDLOGY DRIVE N. VENICE. FL 34275 'P.O. BOX 1529 NOKOMIS: FL 34274 CERT. OF AUTH. #29296 SASH VISIBLE LIGHT FORMULAS: Ap:;,v iz: Cc :;r ' 51::J1 t.w WIDTH=WINDOW WIDTH -4.875• HEIGHT=SASH HEIGHT-4.293' "tcr:�_•'i.:•-.::... r-'= 3ay.-s. i•t ;i': FIXED VISIBLE LIGHT FORMULAS: Yf'••i�ivi;. P;eo:::o: WIDTH =WINDOW WIDTH HEIGHT =WINDOW HEIGHT ASH HEIGHT- 3.33E t 111111111/j e; k 14D.58705 _ _= jLf 'SOT'•.. RLORIOP•' Revised Br Defe: Rovialon: Revised W. Dote: Revislon: A. LYNN MILLER. P.E. RE A58705 Dowdptfon: Drom W. ANCHOR QUANTITIES A J ROSOWSKI 7ft., I. SH WINDOW -SMALL MISSILE 11/11/11 Serfas/Alodeb Scofe: Sheet Drowng No. Rev-. SH-800 NTS 3 OF 7 MD-SH800SM-01 TARI_F a' ANCHOR QUANTITIES REQUIRED -Group B Anchors Sash Height or Height Range OveraO Window Width 19-1/8" 26-112" 33" 3T 41" 45' 49' 53.118' Jarnt g ¢ m "` Jamb 5 Jamb S I Jamb o Jamb Jamb 9 Jamb Jamb m ¢ m w g In ¢ g m Q m ¢ m ¢ rc m 2411T 12,/4" (Equal -Lila) 1 2 1 1 2 1 1 2 1 1 2 1 1 2 2 1 2 2 1 2 2 1 2 2 25.1/2' 13-1/4" (Equ2FUle) 1 2 1 1 2 1 1 2 1 1 2 1 1 2 2 1 2 2 1 2 2 1 2 2 37' 19" (Equal-Ule) 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 3 2 2 3 2 2 3 2 19-&8' (Equal-Ute) 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 3 2 2 3 2 2 3 2 38.318' 19" Llvu 19-91le" 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 3 2 2 3 2 2 3 2 16" Ihru 1&7&16". 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 3 2 2 3 2 2 3 2 13'thru 16-1511W 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 3 23' (Equa6Ute) 2 2 1 2 2 1 2 2 2 2 2 2 2 3 2 2 3 2 2 3 2 2 3 2 22'thnl 22.1&7S' 2 2 1 2 2 1 2 2 2 2 2 2 2 3 2 2 3 2 2 3 2 2 3 2 45' 19' 2 - . 2 1 .T, 2. 3 - - 13 16" thm 1&1&16' 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 3 2 3 3 3 3 3 3 13" thm 15-15/16° 2 2 1 2 2. 1 2 2 2 2 2 2 3 2 2 3 2 2 3 2 3 3 3 3 25314" (Eque1-Ute) 2 3 1 2 3 1 2 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 4 3 25" lhru 2&11115" 2 3 1 2 3 1 2 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 4 3 5D.Vlr 22* thru 241&16' 2 3 1 2 3 1 2 3 2 2 3 2 2 3 2 2 3 2 2 3 3 3 4 3 19" Ihnt 21-1&1(r . 2 2 1 2 2 1 2 2 2 2 2 2 2 3 2 3 3 2 3 3 3 3 3 3 16" thru 18-1&i6" 2 2 1 2 2 1 2 2 2 3 2 2 3 2 2 3 3 3 3 3 3 3 3 3 W 13' thru 15.15116, 2 2 1 2 2 1 3 2 2 3 2 2 3 2 2 3 2 3 3 2 3 4 3 3 32" (Equal -Cite) 2 3 1 2 3 1 2 3 2 2 3 2 2 4 2 3 4 2 3 4 3 3 4 3 3 31" ltru 31-1&16" 2 3 1 2 3 1 2 3 2 2 3 2 3 4 2 3 4 2 3 4 3 3 4 3 26'thm3D•15116" 2 3 1 2 3 1 2 3 2 3 3 2 3 3 2 3 4 3 3 4 3 3 4 3 " W thru Z7-15116" . 2 3 1 2 3 1 3 3 2 3 3 2 3 3 2 3 3 3 3 4 3 4 4 3 22'11YU241&15" 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 3 3 4 3 3 4 4 3 2 19' Ihnl 21-15116 3 2 1 3 2 1 3 2 2 3 2 2 4 3 2 4 3 3 4 3 3 4 3 3 V 16' Ow 18.15116' 3 2 1 1 3 2 1 3 2 2 4 2 2 4 2 2 4 3 3 4 3 3 5 3 3 13' duu 15.15116' 3 2 1 3 2 1 4 2 2 4 2 2 4 2 2 4 2 3 5 2 3 5 3 4 37' (Equal-Ule) 2 3 1 2 3 1 3 3 2 3 4 2 3 4 2 3 4 3 3 5 3 3 5 3 W thiu 36-1&16" 3 3 1 3 3 1 3 3 2 3 4 2. 3 4 2. 3 4 3 3 5 3 4 5 3 31" tliru 33.15116- 3 3 1 3 3 1 3 3 1 2 3 3 2- 3 4 2 4 4 3 4 4 3 4 5 3 73" 26' thm 30-16116' . 3 3 1 3 3 1 3 3 2 3 3 1 2 4 3 2 4 4 3 4 4 3 4 4 3 W thru 27-15116' 3 3 1 3 3 1 3 3 2 4 3 2 4 3 2 4 3 3 4 4 3 5 4 4 W thni 24-15116" 3 3 1 3 3 1 4 3 2 4 3 2 4 3 2 5 3 3 5 1 3 1 3 5 4 4 19" thru 21-1&16' 3 2 1 3 2 1 4 2 2 4 2 2 5 3 2 5 3 3 5 3 3 5 3 4 16'thm 16-1&16" 3 2 1 3 2- 1 4 2 2 4 2 2 5 2 2 5 3 3 5 3 3 6 3 4 39-1/2' (EqueWte) 2 3 1 2 3 1 3 4 2 3 4 2 3 4 2 3 5 3 3 5 3 4 5 3 37' thru 39-7116' 3 3 1 3 3 1 3 4 2 3 4 2 3 4 2 3 5 3 4 5 3 4 5 3 34" thru 3&15116' 3 3 1 3 3 1 3 3 2 3 4 2 4 4 2 4 4 3 4 5 3 4 5 3 78" 31" lhni 33-1rd16' . 3 3 1 3 3 1 3 3 2 4 3 2 4 4 2 4 4 3 4 4 3 5 5 3 28" thm 30-16116' 3 3 1 3 3 1 4 3 2 4 3 2 4 3 2 4 4 3 5 4 3 5 4 4 25'thru 27-15116" 9 3 1 3 3 1 4 3 2 4 3 2 4 3 2W13 5 4 3 5 4 4 22' ttuu 241&16" 3 3 1 1 3 3 1 4 3 2 4 3 2 5 3 2 5 3 3 6 443 2 1 4 2 1 q 2 25 2 2 5 3 2 8 3 3 8 3 4 ---'-iI-,v„r,v uvr.w me-IH MIJ rKUVIEW/ UKRL UVNNUUW4IIUN. TABLE 4� Anchor Group Anchor Substnto Min. Edge Olstance Min. Embedment g #14. Steel SMS (G5) or #74, 410555MS P.T. SWAhem Pine (SG - .55) 9116" 1-3/6' 60663-TS Alum 3/8" 116" .. Steel Stud, Gr. 33 min. Stir 0.045 16 Ga . ( ) A36 Steel 318" 116" .. 1/4" CreteFle: P.T. Southem Pine (SG = .55) 1" 1-T4" 5/16' Steel Ullracon I Follow Block, (ASTM C90) 1 3.1/8' 1-114" •• MIMIMUM Ur 3 1 HKEAUS BEYUNU THE METAL SUBSTRATE. FIGURE A SASH SECTION (WITH INSULATED GLASS) T SASI VISIBI LIGH HEIQ I 1070 TECHNOLOGY DRIVE N. VENICE, FL 34275 P.O. BOX 1529 NOKOMIS; FL 34274 CERT. OF AUTH. #29296 NOTES: 1) FOR BUCK DIMENSIONS, SUBTRACT V __=^'FROND WIy4D�^(JKIR�H QB,tiF1G}iL,_.a�._�--Y.-..r.,..,.._�....+�"•- — 2)'MR' = 'MEETING RAIL- 3) FOR OVERALL SASH WIDTH, SUBTRACT 2-9/16" FROM THE WINDOW WIDTH. 4) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION SHOWN ON THE TABLE. T. 5) SEE SHEET 2 FOR INSTALLATION LAX. DETAILS. SASH VISIBLE LIGHT FORMULAS: WIDTH = WINDOW WIDTH-4.875' HEIGHT = SASH HEIGHT - 4293' FIXED VISIBLE LIGHT FORMULAS: WIDTH = WINDOW WIDTH -3.5' HEIGHT = WINDOW HEIGHT - SASH HEIGHT-3.336' (eneed try: vote: Revielon: 4.rlsed BY Oct.: Re"on: D—iption: ANCHOR QUANTITIES B Title: 3H WINDOW -SMALL MISSILE f� `1t111vr,u,1111 ////� No. 58705 STA E FLOR10? C9� ONAt- �? A. LYNN MILLER. F.E. _P.EJ158705 O.- E�': J ROSOWSKI SH-800 I NTS 1 4 OF 7 1 MD-S 11/11/11 TABLE 5- ANCHOR QUANTITIES REQUIRED -Group C Anchors - Sash Heightor Height Range Overafl Window Width 15118' 26-11T 33' 37" 41' 45' 49" 531/8" Jamb Jamb ro Jamb v Jamb m Jamb 9 Jamb E Jamb W x Jamb m m E m � � a � ¢ m z: � g � Oil m b ¢ � 6¢m m 24-10 12-T4" (EquaFUte) 1 2 1 1 2 1 1 2 1 1 2 1 1 2 2 1 2 2 1 2 2 1 2 2 25-112' 13.114'(EquaFUte) 1 2 1 1 2 1 1 2 1 1 2 1 1 2 2 1 2 2 1 2 2 1 2 2 37- 19' (Equal-Ule) 2 2 1 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 19.51E (Equal-Ute) 2 2 1 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 R, 19" Jim 19-9/16" 2 2 1 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 16" Ihru 16.1511fi• • 2 2 1 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 13" ttru 1515HE" 2 2 1 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 23" (Equal-Ute) 2 2 1 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 3 2 22" Jim 22-15/16" 2 2 1 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 3 2 45' 9�Ihot21.1 to^_�_. 1 - 2- �.2• 2 - is, ttru1615116" 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 13'tl7u 15-16115" 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 25314' (Equal -Lit.) 2 3 1 2 3 1 2 3 1 2 3 1 2 3 2 2 3 2 2 3 2 2 3 2 25'ttru2511/16' 2 3 1 2 3 1 2 3 1 2 3 1 2 3 2 2 3 2 2 3 2 2 3 2 �8,• 2 HTU 24-15/16' 2 3 1 2 3 1 2 3 1 2 3 2 2 3 2 2 3 2 2 3 2 2 3 2 10" thru 21-1511E ♦ 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 1E thru 16-15116' 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 13' ttsu 151511E 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 3 2 2 3 2 3 3Y (Equal-Ule) 2 3 1 2 3 1 2 3 1 2 3 2 2 3 2 2 3 2 2 3 2 2 3 2 z 31" Ihu 31-15116 2 3 1 2 3 1 2 3 1 2 3 2 2 3 2 2 3 2 2 3 2 2 3 2 •g 28" lhru 361511E 2 3 1 2 3 1 2 3 1 2 3 2 2 3 2 2 3 2 2 3 2 2 3 2 63. 25" thm 27-15HE . 2 3 1 2 3 1 2 3 1 2 3 2 2 3 2 2 3 2 3 3 2 3 3 3 22' ltru 24.1511E 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 3 2 3 3 3 2 lIr thru 21-1511E 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 3 0 1E ltru 18.15116' 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 3 13'ttvu 151511E 3 2 1 3 2 1 3 2- 1 3 2 2 3 2 2 3 2 2 3 2 2 4 2 3 37' (Equal-Ute) 2 3 1 2 3 1 2 3 1 2 3 2 2 3 2 2 3 2 2 4 2 3 4 3 34' 1hn13515118" 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 4 2 3 4 3 31" ttuu 331511E 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 3 2 3 4 3 " 2W ttru 361511E • 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 3 2 3 3 3 25"thru27-1511E 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 3 2 3 3 3 221NU24-1511E 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 4 3 2 4 3 3 19'lhiu 21-16MIr 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 4 2 2 4 2 2 4 2 3 tE Ilvu 1&15/18' 9 2 1 3 2- 1 3 2 1 3 2 2 4 2 2 4 2 2 4 2 2 4 2 3 39-1/2" (Equal-Ule) 2 3 1 1 2 3 1 2 3 1 1 2 3 2 2 3 2 2 3 2 3 4 2 3 4 3 3r thru 39-7/18" 3 3 1 1 3 3 1 3 3 1 1 3 3 1 2 1 3 1 3 1 2 3 3 2 3 4 2 3 4 3 34" thru 36-15116" 3 3 1 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 4 2 3 4 3 7B" 31" thru 33-15116' • 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 3 2 3 4 3 2E tluu 361511E 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 3 2 4 3 3 2E ttru 27-1511E 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 4 3 2 4 3 2 4 3 3 22'thru 24-15116" 3 3 1 3 3 1 3 3 1 3 3 2 4 3 2 4 3 2 4 3 2 4 3 3 20' lhru 21-1511V 3 2 1 3 2 1 3 2 1 9 2 2 4 2 2 4 2 2 4 2 2 4 2 3 • SASH HEIGHT RANGE INCLUDES THE STANDARD PROVIEWI ORIEL CONFIGURATION. TABLE 6: Anchor Group Anchor SubsltoM Min. Edge Dlstanu Mln. Embedment 1/4" Sleel Uitmeon Concrete (min. 2.7 k3i) 2-1/2" 1.31E C 1/4" CreleFlex Concreto (min. 3.35 ks) 1" 1.314" Hollow Block, (ASTM C90) 1.314" 1-1/4' 511E Steel Ultrecon Concrete (min. 3.5 ksi) 2-3116" 7-3/4' Grouted -filled Block, (ASTM C90) 2-112" 1-3/4" Hollow Block, (ASTM C90) 1 31/8" 1-1/4' NOTES: FIGURER: SASH 1) FOR BUCK DIMENSIONS, SUBTRACT 1" sRp�_-_ �...-,_FROM.SYINIIQ)AI.1fYID7}iO3.HElGHT..,,-.� SECTION (WITH 2)'MR' _ "MEETING RAIL' INSULATED GLASS) 3) FOR OVERALL SASH WIDTH, SUBTRACT 2-9/16" FROM THE WINDOW WIDTH. 4) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION SHOWN ON THE SASH TABLE, VISIBLE SASH LIGHT HEIGHT, 5) SEE SHEET 2 FOR INSTALLATION HEIGHT 39-1/2' MAX. DETAILS. L SASH VISIBLE LIGHT FORMULAS: WIDTH = WINDOW WIDTH - 4.875" HEIGHT=SASH HEIGHT-4.283' FIXED VISIBLE LIGHT FORMULAS: WIDTH = WINDOW WIDTH - 3.5' HEIGHT = WINDOW HEIGHT - SASH HEIGHT - 3.336' Re,fdon: Revised By: Data �v{s1�; - ® DeeeNpUon: ANCHOR QUANTITIES C 1070 TECHNOLOGY DRNE rid..- N. VENICE, FL 34275 SH WINDOW -SMALL MISSILE P.O. BOX 1529 NOKOMIS, FL M274 Serf-Aodel.. Srnte, Sheeb CM. OF AU7H. #29296 SH-800 NTS 5 OF 7 AP;~:m•cd r= ccr; :;inn ::.� for nnao5` D M1Otr1 � L - ..011I 111111///i. \`\ \ IO....r ... I— M/CCU ���/ Q N0.58705 STA E F ' -- .N.4 j'\ A. LYNN MILLER, P.E. P.E.# 58705 J ROSOWSKI Date: 11/11/11 Drowing No. Rm MD-SH800SM-01 TABLE T. Item Dwg.A I Parts Description Material 1 I 4002A I 6i2226w Frame Head 5063-TB 2 4050D 1 64050DW Frame KG Rise SM 6063-16 3 4004 612227W Frame Jamb 5063.76 5 4054B 64054BW Fixed Meeting Rail 606316 6 4053 64063W Meeting Roll Reinforcement Tube 6061-16 7 4006D CANSW Sash Top Rail W63.15 8 4009 7640D9W Sal LOek 606315 11 4051A 64051W Sash Bottom Rall -t0•Rise 6063.15 12 4008 612231W Sash Side Rail 606375 13 1155 781P5A 98 x 1' Quad Fri. SMS Steel or 410 SS 15 1179 710)34PPSDAX #10 x 314" Ph. Pn. TEK 163E SS 16 1 1016 7858WW N8 x 510• Ph. Fl. SMS Steel 17 1 4087 440B7AWR Sash Bottom Rall End Cap Rigid PVC 18 4064 44064W Meeting Reg Relnt. Tube End Cap Rigid PVC 19 4081 64GBIW Head Fastener Coter(D Q 6053.16 20 947 41722W 318" Qa. HDle Plug Rigid PVC 21 1096 71797W Top Sweep Latch Cost Zinc 22 4080B 74080BK Mtg Rall Sweep Latch Plug Rigid PVC 23 1085 SP NG Sill Latch Spring Spring Steel 24 1226D 61226DW Wstp., Bulb V(rryl (@ Sash B011om Rail) Flex PVC 70 2 26 4066 64066G .18r x .230° Fin Seal 27 1 10B2 61062G .18r x .270` Fin Seat 28 16M 7PAD1627 Adheshe Open Cell Foam Pad polyalhyiens 29 74087 Hi -Rise S01 Gasket Polyethylene 30 4076D 74076DW Head Gasket Poly eN lane 31 40W 64053W Sash Stop Coter(Ali Balances) 606375 32 1080 6BALCVRO16W Balance Corer All Balances Rigid May] 34 75831KEZ Celdeeil EZ-IJa Balance 35 7634AA q8 x 314' PH PIN (EZLIII) Steel 36 4085 44085WR Sash CoterG0ltle EZ-Uft VI I 36 1 1 Caldwell Ulxa-UB Balance (Sash > 55 lbs) 39 7N(1FPAX 18 x 1' Ph Fl. St. Sit. (Ultra-UR) 410 SS 40 1066 44068WR Sash Cater Gulde (Ulho-u0) Vinyi 41 402&1 7ULBRKT Seen Bracket (UIVaLill) Steel 42 7832X72FPFX ! 32 x V2' PH FL SS - Ultra-Ua 410 5S 43 - 6OURAKS16 Dursseel - 5/10' (IG Only) 45 1622 11622K Laml Salting Block 3132 x 25l64' x 1' Neoprene, B5 dum 46 1715 71715K IG Setting Block 116" x 314' x 1-1114' Neoprene. 85 duro 47 966 6o968AW 3r8" Lams Glazing Bead 6083-T5 49 4039-11A 64039BW I LONG Glazing Bead 608375 50 1224 6TP247W .It, Bead Weatherstrip, IG Polyethylene 51 1225 6TP248K Bulb Bead Weatherstrip Polyethylene 52 134 65615W Adtlon Flan a O L 6063-75 53 1014E 61014FW Screen" Allsrdn= 54 1630 47042W Screen Comer Key xditgs Vinyl 55 1631 47041 W Screen Comer Key wlout Rings Vinyl 56 320B 7320SPNG Screen SpringSpring Steel 57 1624 61624K Screen Spline -.135 UHL Foam Rubber 58 61635K Screen Spline-.135 ilia. Hard Rubber 59 61816C34 Screen Cloth Fiberglass 61 Dow Coming 899 Silicone Glazing Saelard or Equiv. 95 118' A -.090' DuPont PVB - 3116- T 96 118• T. 114• Air- 118' A -.090" OuPord PVB - 3116' T le 2.945' JTO .125' 1.363' I I L2.709" .062' 2.646'. 1.500, OFRAME HEAD .062" 6063-T6 ALUMINUM .50D° �- 1.748' •750' 2.783' 1.341° O 60FRAME T8 ALUMINUM O 6063. 6JAMB SASH BOTTOM ALUMINUM t1 6063T6 ALUMINUM IL MEETING O REINFORCEMENT 6081-78 ALUMINF-MTT IIrrjjIIII I -T DaD° 54' 688' IJVLI �JIII .857 2.1f . 1.705' I 1.3I49' -►-I .062' � I� 1.533 .907 .062' -4 HEAD FASTENER COVER 18 8083-T6 ALUMINUM FIXED MEETING SASH TOP RAIL SASH SILL LOCK SASH SIDE RAIL O 6063-TB ALUMINUM L O 6003•TO ALUMINUM O 6063•T5ALUMINUM a 6063-T5 ALUMINUM 95 98 13(16" NOM. GLASS NOM. GLASS STACK 1/8' TEMPERED CAP GLASS STACK .090' DUPONT PVB 5/16' AIRSPACE 3/16'TEMPERED .090'DUPONTPV13 GLASS 3116' TEMPERED 1/8°ANNEALED 118"ANNEALED GLASS GLASS /-,\ GLASS EXTERIOR a 050' 1.512' �+ 1.167' 216• .738' .040' •881' .661' .050° i I IP 1.09a° �-- 1.089' .168' �050' 31 6063•'T ALLUMNUSAS OP COE47 M 6063T5ALLNG 48UMINUM 6063-TSABLUUMIIUM 52 60g36A LA .524' MIN. GLASS BITE l7_V '-. W ttl H II .524" MIN. GLASS BITE 3/8" GLAZING DETAIL 11111111 <_YNN 49q��!��, � ;''VCENS@ •'•.� No.58705 = Dr�r� _ p,TA. ��'\_�� '�1;SS/ONAL tilt A. LY�NIk)I EXTERIOR a 43 4� AT; �vo3 =° m:.+S lag cr6h the 13116" I.G. GLAZING DETAIL r7r:1: Ole'= Revived NOf,1 . W. Dote: Revlon: �t Roused By: Date: Ravion: ® Deecrip0onr Drown By: BOM 8r PART DETAILS J ROSOWSKI 1070 TECHNOLOGY DRIVE 17,Us. Dote: N. VENICE, FL 34275 SH WINDOW -SMALL MISSILE 11/11/11 P.O. BOX 1529 NOKOMIS; FL 34274 I Serf-/AfodeL• Score: - Sheet: Dmwing N0. Raw CUM OF AUTH. #29296 SH-800 NTS 6 OF 7 MD-SH800SM-01 11/16' SILL WEEP NOTCH @ EACH END FRAME .ceris f flee�� ASSEMBLY DETAILS 1`�' - *' No,58705 * /_ _ * - 13 11/18' SILL WEEP" — NOTCH ®EACH �'•. 1 29 - "O •'. �- `( NOTES: END STIR E O : .<u % = 1070 TECHNOLOGY DRIVE 1)GLASS HARDW HARDFIXEDWARE BOTHTE BEADING OF BALANCES SHOWN, CLARITY. ' T�''•. FCOR{OP'••' N. VENICE. FL 34275 2) HARDWARE FOR BOTH TYPES OF BALANCES SHOWN. 'iDWARE , Ss��""" E� ` P.O. BOX 1529 REQUIREMENTS USED FOR EACH BALANCE TREFER TO TABLE 7, SHEET 5 FOR SPECIFIC TYYPE.. A. L 14 AL ,RE, NOKOMIS: FL 34274 A. L1�It_ I.{I�LER, RE, P.EN 56705 CERT. OF AUTH. 929295 Deeerfpllon: ASSEMBLY DETAILS WINDOW -SMALL MISSILE NTS 1 7 OF 7 Appm edmcomplyingtvkhthe Florida Building Cote NOAn Ostc o Ah 'c P• ontrolO� By t Drum By: J ROSOWSKI Dale: 11/11/11 D;vWng No. Rer. MD-SHSOOSM-01