Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSNov 131212:53p Packard Roofing ' S 772-46"- -'^78 p.1 r DATE: FEES DUE: t ° RECEIPT #: Permit #: _ Planning & Development Services Department Building & Cade Regulation Division ® n 2300 Virginia Avenue Ft. Pierce, FL 34982-5652 Tel. 772-462-1553 f / Veo APPLICATION FOR ROOF PERNUT SEEFEVERSESIOEFOR INSTRIJCTIO14S �(/r'�e C 1. Location/Site Address: 7327 Marsh Terrace �U�ty 2. ParceLID Number: 3321-804-0021-000-6 A Office Use Only Section Township Range Map Page Zoning Land Use I Jnj i Is 3. Description of Project or Work Activity: Re -roof Single Family Residence 4. Total Roof Area (square feet): 4400 5. Roof Pitch: 6/12 6. Type of Roof: [ IF iberglass Shingle [x] Concrete Roof Tile [ ] Wood Shake / Shingle [ ] Tar & Gravel [ ] Modified Bitumen [ ] Other [ ] Product Approval required for all types of Roofing Material (2 Sets) [ ] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product Approval attached Roof Mitigation per F.S. 553.844 will be required. 7. Owner Information S. Contractor Information Name: Timothy Catalina � C rV\e— Address: 7327 Marsh Terr. City: Port St. Lucie State: FL Zip: 34986 Phone: 465-7418 9. Value of Construction: S 21,000.00 FL Reg/Cert #: CCCA17517 County Cert #: Business Name: Packard Roofing Cell Phone: 468-3723 **Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval. CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in compliance with all appli ble ]aw ulating construction and zoning. WD PRIN'C-QlALIFIERS O NERS NA ME SIGNATURE OF OUALIFIER/O►'V STATE OF FLORIDA, COUNTY OF ACiGiiOWLEDGEO FsEFORE ME'11115 � �A"r OF Ei►Ld aY Yi RO IS PERSON LY KNOWN _L//TO ME OR HAS PRODUCED AS IDENTIFICATION r1O1ARY PUBLIC-6TATE OF FLORMA hanie P. Smith sIGNA RE OF NOTARY TYPE OR PRINT NAME OF NOTARY AWIMBsion #DD902671 COMMISSION NUMBER `,,,•`.Expires: SEP, 01, 2013 ifONE-ED TEIRti hTI A11 C1C BONOLyGCO,, ING NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF CONMfE+ NCEMENT MAY RESULT IN YOUR PANTNG TRICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Revised 412612010 rdl Nov 131212:47p Packard Roofing 772-4eo-r")78 p.1 JOSEPH E. SMITH, CLERK Li <,sRE CIRCUIT COURT - SAINT LUCIE COUNTY', A FILE # 3764760 OR BOOK 3449 PAGE 103, Recorded 11/01/2012 at 10:27 AM NOTICE OF COMMENCEMENT Permit NO; Tax Folio No. 3321-804-0021-000-6 State of Flo County of St. Lode Theundersi dhereby gives nolloothat Iroprovementwill bemad atocerta:nraalproperty, andInatmldancewith Chaplet 713,Florida Statutes, the (dlowln information Is provided N thls Notice of Commencement. 4 (Map 33121n) (OR 1404-1214: 1628-1257) 4erwar Owmrin atioo!!��a onnatbrtiftheLessmconractedfor the improve ear Name Ifri001Y L:a Ills Address Irtterestlnp P.-r po RimnfP Name and a s3 of fee simyle t tleholder (tf ddferant from Owner Ilsted above): i Contradar Name: Packard Roofing 8 Waterproofing, Inc. j contractor ress; 21R2 NW Reeerye Park Trace Port St. _ i .j _Phone Number. 4§P-3723 FL. 98 surety (If a (cave, a veeoftthpa)tnent bond is attached): Annunt of bond: S i Narrreanda ress: Phone number. j LenderNamic Phone Number Lenders address: s' Peffsons vAd!ilre the State of;lorWa deslgmted by Owner upon whom nufloes or other doewitents may be swYed as probided by Section 7l1,31 (1j (2)7., Fonda St3bmes. Name: I Phone Number. Address: I :i In aci tontohlmecIrorhersel;,Ownerdesignates of to receive aCOPY ofthe Llenor's Notice asprovlded In Section 7111311) (b), Florida Statutes. Phone number of person or entity designated by owner: EVtratiendateofncticeofcommentementItheexpirationdatemaynotbebefomthecompletionofeonstructlonandfinalpavmenttothe icontractor, but will be i year from the date of recording untess a different date Is speclrwn3 WARNING TO OWNER ANY PAYMENTS MADE BY mE OWNER AFTER THE EXPIRATION Of THE NOTICE OF COMMENCEMENT ARE CONS DERED J IMPROPER PAYMENTS UNDER OiAPTER713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR I 1MPAOVEM To YOUR PROPERTY.ANOTICEOFCOMMENCEMENTMUST8EREOORDEDANDPOSTEDONWigJOBSITEBETORETHEFIRST 1NSPECriCW iFYC)U INTEND TO OEITAJN FINANCING, CONSULT WITH YOUR LENDER ORAN ATTORINEYBEFORECOMMENCING WORXOR RECORDING OUR NOnCE OF COMMENCEMENT. i Under penat y of perjury, i declare that) have read the foregoing notice of mmmencemalt and that the fate stated therein aretme to the best of } my krrawled e an belleF, x A. . .I {Signature Cf Owartor Lessee, or Owner's onessee's Authorized Officer/Director/Partner/Manager I (SlgnetorysTnlejOFRoe) The foregoin Instrwrmnt was acknowledged before Tne this ,cri Qf Qf. Z61,7, gy T 'r 4— as, jcjcj nit( for N of Pe �TYPo oraudrority (e g. officer, trustee) Pa rty on behalf of whom iniMment was exeaded 1� it PesanaUY known r Produced Identifiatton^ S+l reef Notarypublic-Stateoffioid YP4RLjCST1, 1'UI? OF [Pi1nt,Type,orRampCommisslonedNem c*NotaryPubl{ Ste';jenie P S=t�baafldentfAcattonproduced ` CAmmixnoo N D%02671 * E empires: SEP.01, 2013 STID� t7IRV Ai IAYriC llOh9ar7 CD�IISC &T�i-iF J� �IJT7�i4iA .:i. LI.auII- CC1�iITY ";I GfSTGCEP,T;FYTRAT Ti?15?SA rFJEANUr,:0F,F!r-CTC'0,11Y Or Tt!-F 08IGI11AI ' H E. S N,ITH: CLEPtK 111 n . hlov 161211:37a Packard Roofi y'-' -�468-9978 p.1 Re: Permit # lam{ 1i "01 Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue _ Fort Pierce, FL 34982 772-462-2165 or 772-462-2172 Fax: 772-462-6443 ROOF INSPECTION AFFIDAVIT I, bau r r _f z(-�(C) , licensed as a(n Contractor /Engineer/Architect (Please print name & circle license type) *FS468 Building Inspector *General, Building, Residentiai or Roofing Contractor or any individual certified under 468 F.S. to make such an inspection. On or about // -/gyp -" /pZ , I did personally inspect the roof deck nailing (Date) work at: %30 7% dJQ r5l/1 (Job site address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S.) Signature and Sea! STATE OF FLORIDA COUNTY OF .5 - LJCs -Q- LC'_A17S1-7 License # Sworn to and subscribed before me this day of /VOtl2 20-Lo�- by 17�' ; G( > C�CL:1! ^� Who is personally known tome or who has produced as identification. Notary Public, State of Florida Signature of Notary: Commission Number: (Seal) En 01/19/2011 NOTARY pUBLICSTATE OF FLORIDA Stephanie P. Smith MCommission #DD902671 %',-° Expires: SEP. 01, 2013 BONDED TNRU ATLANTIC BONDMG CO., IBC. NOV 19 2012 PAC 1�,,ARfl/C,4-rNu(0h Treasure Harvey E:. Koehnen . C oast Professional Engineer #32831 B Lilding a Architect#AR0009471 P2.4 E ngineers, Certified General Contractor #CG Inc. Contractor PAC4<21,20 Ryor-IN , lsle Owner G�TP, L.4 tJ A Job Address 7327 r4Aja5K Aur—e pl- TILE ROOF C—liT IF&RA 13" fiLArU'rN LvP r-4AT = NEW ROOF RE -ROOFS REPAIR AREA oar 005:r' TILE ROOF PLAN NEENNNENEEMMMMMMMMMME MMMMMMMMMMMMMMMMMMMME MMMMMMMMMMMMMMMMMMMME MMMMMMMMMMMMMMMMMMMME MNN2MMMMMMMMM■Me■■■■E ■NN*W 4%*W4i�@fMMMMMMM ■©r"""P"M"""M"vMMMMMM ■MCMz : Ez " =2EzMMM■■MMMi ■MKOWS&MMUMMEM■MMMMM■ ■MMMMMM■MM■MMMMMMMMM■ 720SElyse Circle P S L Florida 34952-8212 PHONE(772) 466-5509 FAX(772) 489-3035 � AI L:h koeh nen @tcbeweb.com ASCE 7-10 & FBC 2010 ENCLOSED BLDG X SEMI ENCLOSED BLDG. OPEN 12- PART 2 LOW RISE C&C SIMPLIFIED RISK CAT 2 / V =150 / EXPOSURE Kzt = 1.0 / ROOF / PITCH -S' /12, h = �S ZONE 1 B @ 'h=30 = x A = PSF x 0.6 ZONE.2 B @ h=30 = xA = PSFx0.6=--38,1 a=_4— ZONE 3 B @ h=30 = x A = PSF x 0.6 -151, a = Mp = (PA) - Mg = S?+3 x N 0.2M - Mg MpA_L < Mf = (5 ,i� HAR_VEY E. KOEt-lNEN FOAM 3&k (ETA-1 . NOA FI.,&176^ R MORTAR ^ NAIL Professional Engineer 328'i ; 7206 Elyse Circle PADDY SIZE �'+X�A !'WEIGHT NAIL SIZE ^'• NUMBER PER TILE r' Port St Lucie, FL 34952-321 d. RIDGE VENT DCSNI FASTENING NAIL TILE FASTENING MORTAR FOAM X_ (772) 489-3035 fax DRIP EDGE SIZE 3 3 DRIP MATERIAL 2GPAN,111> FLASHING MATERIAL2/-4Ac A -(- DECK TYPE PLYWOOD THICKNESS OTHER BASE SHEET irs P4y5 NO. OF PLIES ( TYPE OF FAS;W�/BONDING 5 eL.f AeltEB tAt� PLY SHEET ^ NO. OF PLIES TYPE OF FASTENERS/BONDING FASTENERS/BONDING: NAILS SELF ADHERING ROOFING NAILS & TINS CAPS FASTENER SPACING FOR ANCHOR/BASE SHEET ATTACHMENT: Field — "oc @ Lap, # Rows — @ oc Perimeter: ="oc @ Lap, # Rows - @ =" oc Corner: =" oc @ Lap, # Rows=@ oc T f asure C oast B uilding E ngineers, Inc. Harvey E. Koehnen Professional Engineer #32831 Architect #AR0009471 Certified General Contractor #CGCO24776 "these Tables Are For Roof Coverings Roof coverings Installed on Buildings with a Mean Roof Helght of Nor Less Located in Exposures B, C or D `fable R301.2 [2] ate• Q5, (: 7- Ib COMPONENTS AND CL.AD13ING WORST CASE DESIGN PRESSURE [PSF]. 160 Etp B 160 EYp C 160 Ecp C 160 Exp D 160 Exp D (One story (Two story*) (One story") (Two story Roof.> 0 to 7 degrees Zone 1 -27.6 -33.4 -38.7 -40.6 -45.9 7degrees =11/2 /12 pitch Zone 2 -46.4 -56.2 -66.0 -68.3 -77.1 Zone 3 -69.8 -84.5 -97.7 -102.7 -115.9 Roof > 7 to 27 degrees • Zone 1 -26.3 - 30.7 - 35.5 -37.2 - 42 27 degrees = 6/12 pitch Zone 2 -44,1 - 53.4 -61.8 -64.9 -73.3 Zone 8 -65.1 -78.8 - 91.2 - 95.7 -108'.1 Roof > 27 to 45 degrees Zane 1 - 27.8 -33.7 -40.0 -40.1 -46:2 45 degrees =12/12 pitoh Zone 2 - 32.4 -89.3 -45.4 -47.7 -53.8 Zone 3 - 32.4 -39.3 -45.4 - 47.7 -53.8 ED 150ExpC 150ExpC 150ExpD 150 Exp D (one story'") ( two story*) (one story}) (two story-) R.bof > 0 to 7 degrees Zone 1 -24.3 -29.6 -34.1 -35.8 -40.4 7degrees = 1112112 pitch Zone 2 -40.8 -49.4 -57.2 -60.0 -67.8 Zone 3 -61.4 -74.3 -66.0 -90.3 -102.0 oof > 7 to 27. degrees Zone 1 -22.2 - 26.9 41.1 -32.7 - 36.9 27 degrees = 6/12 pitch Zone 2 -38.7 - 46.9 - 54.2 -56.9 - 64.3 Zone 3 . -57.3 . - 69.4 - 80.3 -84.3 - 95.2 Roof > 27 to 45 degrees Zone 1 - 24,3 L29.5 --3Q.1. -35.8 -40.4 X 45 degrees = '12-/12 pitch Zone 2 - 28.4 -34.4• -39.8 -41.8 -47.2�. 1 Zone 3 - 28.4 -34.4 -39.B -41.8 -47.2 One �tbi y"' tff Onostory building with a maximum mean root' height of 15 felt HA13VEV E. KOEHNEff" Professional Engineer 32831 7205 Elyse. Circle Two story' = two story building with a maximum mean.roof height of'so fee Port St Lucie, FL 34952-3212 (772) 489-3035 fax -if -allowed by,the Miami Bade N.O.A or Florida Product Approval, any system•that does -not meet the midmurn components and cladding pressures for the area that the building is located per this form mey require a Florida licensed engineer to revise the fastener spacing T C B E, Inc. 7205 Elyse Crde PHONE (772) 466-5509 Port Saint Lucie FAX (772) 489-3035 Florida 34952-8212 E-MAIL hkoehnen@tcbeweb.com wea srre http:llwww.tcbeweb.com EXTERIOR RESEARCH & DESIGN, LLC. 1 Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 TRINITY I ERD OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 EVALUATION REPORT Entegra Roof Tile, Inc. Evaluation Report E39310.11.11-1-Ri 1289 NE 9th Avenue FL7804-R7 Okeechobee, FL 34972 Date of Issuance: 11/02/2011 Revision 1: 06/22/2012 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2010 Florida Building Code (HVHZ) sections noted herein. DESCRIPTION: Entegra Concrete Roof Tiles (HVHZ jurisdictions) LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinitylERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity[ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7 Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 HARVEY E. KCIEHNEN professional Engineer 32831 7206 Elyse Circle Pit St Lucie, FL 34962-3212 :, f.: • (772) 489-3036 fax * ,•� = The facsimile seal appearing was authorized _ W' by Robert Nleminen, P:E. on 06/22/2012 � ..; �,•;, +••=4 �c This does not serve as an electronically signed .^',+` document. Signed, sealed hardcoples have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. TrinitylERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial Interest in any other entity involved in the approval process of the product. r�\ ',l TRINITY ERD ROOFING SYSTEM EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Roofing Tiles Compliance Statement: Entegra Concrete Roof Tiles, as produced by Entegra Roof Tile, Inc., have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Code Section Property Standard Year 2007 1523.6.5.2 Physical Properties TAS 112 1995 2007 1523.6.5.2 Wind Driven Rain TAS 100 1995 2007 1523.6.5.2.2 Static Uplift Resistance TAS 101 1995 2007 1523.6.5.2.3 Static Uplift Resistance TAS 102 1995 2007 1523.6.5.2.3 Static Uplift Resistance TAS 102(A) 1995 2010 1523.6.5.2 Physical Properties TAS 112 2011 2010 1523.6.5.2 Wind Driven Rain TAS 100 2011 2010 1523.6.5.2.2 Static Uplift Resistance TAS 101 2011 2010 1523.6.5.2.3 Static Uplift Resistance TAS 102 2011 2010 1523.6.5.2.3 Static Uplift Resistance TAS 102(A) 2011 3. REFERENCES: Entity Examination Reference Date ATL(TST3782) TAS 112 RT0615.01-11 06/28/2011 ATL(TST3782) TAS 112 RT0615.02-11 06/28/2011 ATL(TST3782) TAS 112 RT0615.03-11 06/28/2011 ATL(TST3782) TAS 112 RT0615.04-11 06/28/2011 ATL(TST3782) TAS 112 RT0615.05-11 06/28/2011 Tile Roof Institute TAS 100, TAS 101, 102, 102(A) Membership Confirmation Current PRI (QUA9110) Quality Assurance Service Confirmation 11/02/2011 4. PRODUCT DESCRIPTION: 4.1 BERMUDA FLAT and PLANTATION FLAT are TAS 11 Bermuaa Fiat , Type 3a (flat -profile) concrete roof tiles. Plantation Flat Exterior Research and Design, LLC. Evaluation Report E39310.11.11-1-Ri Certificate of Authorization #9503 FL7804-R7 Revision 1: 06/22/2012 Page 2of7 D. LLMJ IAILUNb: 5.1 This Evaluation Report is for use in FBC HVHZ jurisdictions or other jurisdictions adopting FBC HVHZ requirements. 5.2 Fire classification is not part of this evaluation; refer to FBC Section 1516 or current Approved Roofing Materials Directory for fire rating of this product. 5.3 Reference is made to FBC Section 1512.4.2.4 regarding field testing of completed tile roof installations. 5.4 Applicant shall retain the services of an FBC listed, accredited laboratory to perform quarterly tests in accordance with TAS 112, Appendix W. Such testing shall be submitted to TrinitylERD for review. Exterior Research and Design, LLC. Evaluation Report E39310.11.11-1-R1 Certificate of Authorization #9503 FL7804-R7 Revision 1: 06/22/2012 Page 3 of 7 J TRINITY ERD 5.5 Minimum underlayment shall comply with the RAS 118, RAS 119 or RAS 120, as applicable. Underlayment products shall hold Florida Statewide Product Approval or Local Approval for use in tile roof assemblies in HVHZ jurisdictions. 5.6 Minimum roof deck requirements shall be in accordance with applicable FBC HVHZ requirements. 5.8 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C. Rule 9N-3. 6. INSTALLATION: 6.1 Entegra Concrete Roof Tiles may be mechanically fastened, mortar -set or adhesive -set. Installation shall comply with manufacturer's current published instructions, but not less than the requirements of RAS 118, RAS 119 or RAS 120, as applicable. 6.2 Attachment Calculations: Entegra Concrete Roof Tile shall be evaluated as a Moment -Based System' in accordance with RAS 127-95 (for 2007 Code) or RAS 127-11 (for 2010 Code) using the data outlined herein. Table 1: Aerodynamic Multipliers - X (ft') Tile Batten Application Direct -Deck Application Bermuda Flat 0.189 0.205 Plantation Flat 0.267 0.289 Bella High "S" 0.349 0.378 Estate "S" 0.267 0.289 Galena Spanish "S" N/A 0.235 Table 2: Restoring Moment due to Gravity - MB (ft-lbf) Roof Slope Tile 2:12<9<3:12 3:12<9<4:12 4:12< 5:22 5:12 B<6:12 6:12<0<7:22 0a7:22 BattensR6.84 Battens Direct Battens nett Battens Direct Battens Direct Battens Direct Bermuda Flat 5.225.17 6.37 5.09 6.27 4.98 6.15 4.86 6.00 4.72 5.83 Plantation Flat 7.22 6.85 7.79 6.75 7.67 6.61 7S2 6.44 7.32 6.26 7.04 Bella High "S" 6.19 6.11 6.80 5.99 6.67 5.85 6.51 5.68 6.33 5.50 6.13 Estate "S" 6.14 5.91 6.74 5.82 6.64 5.70 6.50 5.56 6.33 5.40 6.14 Galena Spanish "S" N/A 6.20 N/A 6.13 N/A 6.03 N/A 5.89 N/A 5.74 N/A 5.57 Exterior Research and Design, LLC. Evaluation Report E39310.11.11-1-R1 Certificate of Authorization #9503 FL7804-117 Revision 1: 06/22/2012 Page 4of7 l f TRINITY , �ERD Table 3A-1: Attachment Resistance Expressed as a Moment-Mf (ft-lbf) Fiat Profile Tiles, Mechanically Attached Systems Tile Fastener I Direct -Deck (min. �) n Direct -Deck (min. plyw�) a ens Type # Size Shank Clip Nail One (1) 1 Smooth or Screw N/A 7.3 4.9 Nail Two (2) lOd Smooth or Screw N/A 1 _ - ----f8.8 7.4 Nail One (1) 10d Sm th or Screw Eave 6 19.0 22.1 Nail One (1) 10d Smooth o e e d 24.3 24.3 24.2 Bermuda Flat Nail Two (2) lOd S tlfr'S rew Eave 31.9 31.9 32.2 or Plantation Nail Two (2) Smooth or Screw F -id 35.5 35.5 34.8 Flat il Two 10d Ring N/A 9 38.1 17.2 ;Nail' Two(2)' 10d' Rings N/A 50.32 65.5 48.3' ew One (1) #8 N/A N/A 30.8 3 . 18.2 Screw Two'(2) #8 N/A N/A 51.7 51.7 24.4 1 Installation with a 4-inch tile headlap and fasteners located min. 2%rinch from head of tile. Table 3A-2: Attachment Resistance Exprpssed as a Moment - Mf (ft-lbf) Flat Profile Tiles dhesive-Set ystems ize (inch) Weight (g) TO Substrate To Tile To Substrate To Tile Tile Application Adhesive Mf (ft-lbf) TILE BOND- 1 x 6 1 x 6 10.4 10.4 40.6 Touch `n Seal- StormBond 1.25 x 10 1.25 x 8 8.3 10.2 73.2 Inter- 3M Foam Roof Tile Bermuda Flat Dependent Adhesive RTA-1(formerly 4 x 8 4 x 8 12 12 51.8 or Plantation Polyset® One) 3M 2-Component Foam Flat ' Roof Tile Adhesive AH-160 4 x 4 2 x 4 16 8 31.3 (formerly PolyPro® AH360) 3M 2-Component Foam 2 x 7 N/A 24 N/A 40.4 Independent Roof Tile AdhesiveAH-160 (formerly PolyPro® AH160) 2 x 10 N/A 45 N/A 118.9 Table 313-1: Attachment Resistance Expressed as a Moment - Mf (ft4bf) Low Profile Tiles, Mechanically Attached Systems Tile Fastener Dir ck (min:15/32" plywood) Direct -Deck (min.19/3Z plywood) Battens Type Size Shank CI' Nail One(1)2 1 Smooth or Screw 8.82 11.8, 4.12 Nail Two (2) 10d th or N/A 16.4 21.9 7.1 Nail One 10d Sm0 or Sc Eave 19.02 19.02 22.12 Nail One 10d Smooth or Screw Fiel 24.321 24.32 24.22 Nail Two (2) Od Smooth or Screw Eave 31.9 31.9 32.2 Tw 10d Smooth or Screw Field 35. 35.5 34.8 wo (2) 10d Ring N/A 27.8 37.4 28.8 A Two (2)' 10d' Rings N/A 43.01 1 50.91 w one(1)2 #8 N/A N/A 25.82 25.82 22.92 w Two (2) #8 N/A N/A 47.1 47.1 49.1 Installation with a 4-inch tile headlap and fasteners located min. 2%rinch from head of tile. 2 For one (1) fastener installations, utilize hole that is approximately 4X-inch from the interlocking edge. Exterior Research and Design, I.I.C. Evaluation Report E39310.11.11-1-R3 Certificate of Authorization #9503 FL7804-R7 Revision 1: 06/22/2012 Page 5 of 7 .v' TRINITY, ERD Table 3B-2: Attachment Resistance Expressed as a Moment- Mf (ft-lbf) Low Profile Tiles, Mortar & Adhesive -Set Systems Size (inch) Weight (g) TO Substrate To Tile TO Substrate To Tile Tile Application Adhesive Mf(ft-lbf) TILE BOND- 1 x 6 1 x 6 10.4 10.4 43.8 Touch'n Seal'" StormBond 1.25 x 10 0.75 x 10 8.4 5.1 41.8 Inter- 3M Foam Roof Tile Dependent Adhesive RTA-1(formerly Polyset® One) 4 x 8 4 x 8 12 12 44.0 Estate "S" 3M 2-Component Foam Roof Tile Adhesive AH-160 4 x 4 2 x 4 16 8 31.3 (formerly PolyPro® AH160) 3M 2-Component Foam 2 x 7 N/A 24 N/A 45.5 Independent Roof Tile Adhesive AH-160 (formerly PolyPro" AH160) 2 x 10 N/A 54 N/A 86.6 Mortar Per RAS 120 and Product Approval of Mortar Mfgr 20.6 Table 3C-1: Attachment Resistance Expressed as a Moment- Mf (ft-lbf) High Profile Tiles, Mechanically Attached Systems Tile Fastener Direct -Deck (min.15/32" plywood) Direct -Deck (min.19/32" plywood) Battens Type # Size Shank Clip Nail One (1) 30d Smooth or Screw N/A 5.1 6.8 2.8 Nail Two (2) 10d Smooth or Screw N/A 6.9 9.2 7.3 Nail One (1) 10d Smooth or Screw Field 23.1 23.1 19.0 Nail One (1) 30d I Smooth or Screw Eave 29.3 29.3 24.0 Bella High "S" Nail Two (2) 30d Smooth or Screw Field 27.6 27.6 38.6 or Galena Nail Two (2) 10d Smooth or Screw Eave 38.1 38.1 41.8 Spanish "S" Nail Two (2) lod Ring N/A 28.6 41.2 19.4 Nail' Two (2)' lod' Ring' N/A 33.11 48.1' 50.91 Screw One (1) #8 N/A N/A 20.7 20.7 18.1 Screw Two (2) #8 N/A N/A 43.2 43.2 29.8 installation with a 4-inch tile headlap and fasteners located min. 2%cinch from head of tile. Table 3C-2: Attachment Resistance Expressed as a Moment- Mf (ft-lbf) High Profile Tiles, Mortar & Adhesive -Set Systems Size (inch) Weight (g) TO Substrate To Tile TO Substrate To Tile Tile Application Adhesive Mf (ft-lbf) TILE BOND'" 1 x 6 1 x 6 10.4 10.4 48.1 Touch 'n Sear" StormBond 1.25 x 30 0.75 x 8 8.4 3.9 51.6 Inter- 3M Foam Roof Tile Bella High "S" Dependent p Adhesive RTA-1(fornerly Polyset® One) 4 x 8 4 x 8 12 12 36.2 or Galena 3M 2-Component Foam Spanish "S" Roof rile Adhesive AH-160 4 x 4 2 x 4 16 8 35.3 (formerly PolyPro® AH160) 3M 2-Component Foam 2 x 7 N/A 24 N/A 38.7 Independent Roof Tile Adhesive AH-160 (formerly PolyPro® AH160) 2 x 10 N/A 63 N/A 66.5 Mortar Per RAS 120 and Product Approval of Mortar Mfgr 24.5 Exterior Research and Design, LLC. Evaluation Report E39310.11.11-1-Ri Certificate of Authorization #9503 FL7804-117 Revision 1: 06/22/2012 Page 6 of 7 TRINITY I ERD 7. LABELING: 7.1 Each unit shall bear the imprint or identifiable marking of the manufacturer's name or logo, as detailed below. Tile lots shall be labeled in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. v�7ENTESRR J""� S. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Okeechobee, FL 10. QUALITY ASSURANCE ENTITY: PRI Construction Materials Technologies, LLC. — QUA9110; (813) 621-5777 - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report E39310.11.11-1-R1 Certificate of Authorization #9503 FL7804-R7 Revision 1: 06/22/2012 Page 7 of 7 t EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 CHRISTIAN STREET TD11 IA rry i ERD 353 OXFORD, CT 06478 1 V PHONE: (203) 262-9245 FAX: (203) 262-9243 EVALUATION REPORT 3M Company Evaluation Report 02768.02.06-R3 3M Center F1-6276-113 Building 0220-05-E-06 Date of Issuance: 03/21/2006 St. Paul, MN 55144-1000 Revision 3: 06/20/2012 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been designed to comply with the 2010 Florida Building Code. DESCRIPTION: 3MTm Foam Roof Tile Adhesive RTA-1 LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire the manufacturer or its distributors and shall request of the Building Official. Evaluation Report shall be provided to the user by be available for inspection at the job site at the This Evaluation Report consists of pages 1 through 4. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 HARVEY E. KOEHNEN Professional Engineer 32831 7206 Elyse Circle fort St. Lucie, FL 34962-3212 (772) 489-3036 fax 0�G ti 0;4, The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 06/20/2012 This does not serve as an electronically signed document. Signed, sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Exterior Research & Design, LLC. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Roof Tile Adhesive Compliance Statement: 3M Foam Roof Tile Adhesive RTA-1, as demonstrated compliance with the Florida Building Code through Standards set forth herein. Compliance is subject to the Installation Conditions of Use set forth herein. 2. STANDARDS: Sections 1716.2.1 3. REFERENCES: Entity PRI(TST5878) PRI(TST5878) PRI(TST5878) PRI(TST5878) PRI(TST5878) PRI(TST5878) PRI(TST5878) PRI(TST5878) PRI(TST5878) UL, LLC. (QUA9625) 4. PRODUCT DESCRIPTION: Property Wind Examination SSTD 11 SSTD 11 SSTD it SSTD 11 / TAS 101 SSTD 11 / TAS 101 SSTD 11 / TAS 101 SSTD 11 / TAS 101 SSTD 11-/ TAS 101 SSTD 11 / TAS 101 Quality Assurance Standard SSTD 11 i ." TRINITY ERD marketed by 3M Company, has testing in accordance with the Requirements and Limitations / Reference PFI-006-02-01 PFI-008-02-03 PFI-008-02-04 FOP-009-02-02 FOP-009-02-01 FOP-009-02-03 FOP-009-02-04 FOP-009-02-05 FOP-009-02-10 Service Confirmation Year 1997 Date 05/09/2005 12/14/2005 12/14/2005 11/04/2010 11/08/2010 11/08/2010 11/08/2010 11/08/2010 12/14/2010 Exp. 02/21/2015 4.1 3M Foam Roof Tile Adhesive RTA-1 is a single component polyurethane foam roof tile adhesive distributed in factory, pre -mixed canisters. S. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVHZ. 5.2 Fire classification is not part of this evaluation. 5.3 3M Foam Roof Tile Adhesive RTA-1 can be used with flat, low and high profile tiles or any rigid, discontinuous roof assembly having a current Florida Statewide Product Approval or approved on a local -level by the AHJ. 5.4 Minimum underlayment shall be per FRSA/TRI 07320/8-05 or having a current Florida Statewide Product Approval or approved on a local -level by the AHJ for use with 3M Foam Roof Tile Adhesive RTA-1. 5.5 Field tiles using 3M Foam Roof Tile Adhesive RTA-1 are limited to projects having an Aerodynamic Uplift Moment (Ma)l or Moment Resistance (Mr)2 not greater than the following Allowable Overturning Moment values. Refer to 3M Company published installation instructions for Adhesive Paddy Placement details. ' Determined in accordance with 2010 FBC Section 1609.5.3 and 1609.1.5 2 Determined in accordance with RAS 127-11 Exterior Research and Design, LLC. Evaluation Report 02768.02.06-R3 Certificate of Authorization #9503 FL6276-R3 Revision 3: 06/20/2012 Page 2 of 4 TRINITY ERD Table 1: Field Tiles in 3M Foam Roof Tile Adhesive RTA-1- Overturning Moment Performance Data Tile Adhesive Paddy Placement Allowable Overturning Type Profile Moment (ft-lbf) Interdependent: Concrete Flat Two (2) 48-inch x -12 gram beads on underlayment & one (1) 51.8 4x8-inch x -12 gram bead under nose of tile Interdependent: Concrete Medium One (1) 48-inch x -12 gram bead on underlayment under 44.0 center the flange & one (1) 4x8-inch x -12 gram bead under nose of tile Interdependent: Concrete High One (1) W-inch x -12 gram bead on underlayment under tile 36.2 flange & one (1) W-inch x ^12 gram bead under nose of tile Interdependent: Clay High One (1) 48-inch x-12 gram bead on underlayment under tile 33.5 flange & one (1) 48-inch x -12 gram bead under nose of tile Clay Cap & Pan (Barrel) 48-inch x -12 gram for pans; 2 @ 2x8-inch x -12 gram for cap 162.2 5.5.1 Data in Table 1 relates to installation over a'30/90' underlayment system, as detailed in the FRSA/TRI 07320. Alternate underlayment systems include those having a current Florida Statewide Product Approval or approved on a local -level by the AHJ for use with 3MTm Foam Roof Tile Adhesive RTA-1. 5.5.2 Tile roof systems using tile types or profiles other than those listed above acquiring acceptance for use with 3M Foam Roof Tile Adhesive RTA-1 shall be tested in accordance with SSTD 11 or TAS 101. For the interdependent multi -paddy method, an additional 2- to-1 margin of safety above that specified in SSTD 11 or TAS 101 shall be applied in determining the 'allowable overturning moment' or'attachment resistance expressed as a moment (Mf)'. 5.6 Hip and ridge tiles using 3M Foam Roof Tile Adhesive RTA-1 are limited to projects having hip/ridge design pressure requirements3 not greater than the following values. Refer to 3M Company published installation instructions for Adhesive Paddy Placement details. Table 2: Hip & Ridge Tiles in 3M Foam Roof Tile Adhesive RTA-1- Uplift Resistance Performance Data Tile Substrate Attachment Method MDP (psf) Clay or Interdependent: Concrete 2x PT ridge board Head: One (1) #10 x 2%" screw 186.5 Tile Overlap: 1x6-inch x ^10.5 gram Metal frame with 2-3/8" flange and''/:" Independent: Concrete dip down the center Tile -to -metal, centered along tile: 3x6-inch x 122.6 (East Coast Metals) -30 gram, starting 3-inch from the tile head Metal frame with 2-3/8" flange and h" Independent: Clay dip down the center Tile -to -metal, centered along tile: 3x6-inch x 251.2 (East Coast Metals) "30 gram, starting 4-inch from the the head -' Determined in accordance with FRSA/TRI 07320 Tables 2A through 2D and 3A through 3D. Exterior Research and Design, LLC. Evaluation Report 02768.02.06-R3 Certificate of Authorization #9503 FL6276-R3 Revision 3: 06/20/2012 Page 3 of 4 TRINITY ERD 6. INSTALLATION: 6.1 3M Foam Roof Tile Adhesive RTA-1 and the tile roof assembly shall be installed in accordance with FRSA/TRI 07320/8-05 and 3M Company published installation instructions. 6.2 Hip and ridge boards or hip/ridge metal shall be installed in accordance with the FRSA/TRI 07320/8-05. Proprietary hip and ridge metal shall be installed in accordance with the manufacturer's Florida Product Approval. 6.3 Installation shall be by a Factory Trained Qualified Applicator' approved and licensed by 3M Company. 6.4 Tiles shall be adhered in freshly applied adhesive. Tile must be set within 4 minutes after 3M Foam Roof Tile Adhesive RTA-1 has been dispensed. 7. LABELING: All 3M Foam Roof Tile Adhesive RTA-1 containers shall comply with the Standard Conditions listed herein. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. QUALITY ASSURANCE ENTITY: UL, LLC. - QUA9625; (414) 248-6409; karen.buchmann@ul.com - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report 02768.02.06-R3 Certificate of Authorization #9503 121-6276-113 Revision 3: 06/20/2012 Page 4of4 �. TRINITY; ERA EVALUATION REPORT Polyglass USA, Inc. 150 Lyon Drive Fernley, NV 98408 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 Evaluation Report P12060.02.09-1111 FL5259-R16 Date of Issuance: 02/24/2009 Revision 11: 08/17/2012 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2010 Florida Building Code sections noted herein. DESCRIPTION: Polyglass Roof Underlayments LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinitylERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. , This Evaluation Report consists of pages 1 through 10. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 HARVEY E. KOEHNEN Professional Engineer 32831 720E Elyse Circle Fort St. Lucie, FL 34952-3212 (772) 489-3036 fax M = The facsimile seal appearing was authorized Y b Robert Nieminen, P.E. on 08/17/2012 ,. � . •;..: � ;L,:, +••: This does not serve as an electronically signed �,�.r� is��ONsi.4: document. Signed, sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. TrinitylERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. \1- F � i ROOFING COMPONENT EVALUATION: 1. SCOPE: TRINITY ; ERD Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.3, 1507.3.3, 1507.5.3, Physical Properties ASTM D226 2006 1507.7.3, 1507.8.3, 1507.9.3 1507.2.4, 1507.2.9.2, 1507.3.3, Physical Properties ASTM D1970 2001 1507.11.2 Physical Properties ASTM D6164 2005 1507,11.2 Physical Properties ASTM D6222 2002 1504.6 Accelerated Weathering ASTM G154 2005 1504.6 Accelerated Weathering ASTM G155 2005 1504.3.1 Wind Uplift FM 4474 2004 1507.3.3 Installation Practice FRSA/TR1 07320 2005 1523.6.5.2.1 Physical Properties TAS 103 1995 3. REFERENCES: Entity Examination Reference Date FM Approvals (TST 1867) Wind Uplift 3004091 01/12/2000 PRI (TST 5878) Physical Properties PRI01111 04/08/2002 PRI (TST 5878) Physical Properties PUSA-005-02-01 01/31/2002 PRI (TST 5878) Physical Properties PUSA-013-02-01 12/23/2002 PRI (TST 5878) Physical Properties PUSA-013-02-02 12/23/2002 PRI (TST 5878) Physical Properties PUSA-013-02-03 12/23/2002 PRI (TST 5878) Physical Properties PUSA-018-02-01 07/14/2003 PRI (TST 5878) Physical Properties PUSA-028-02-01 07/13/2005 PRI (TST 5878) Physical Properties PUSA-033-02-01 01/12/2006 PRI (TST 5878) Physical Properties PUSA-035-02-01 09/29/2006 PRI (TST 5878) Physical Properties PUSA-055-02-02 12/10/2007 PRI (TST 5878) Physical Properties PUSA-061-02-02 01/28/2008 PRI (TST 5878) Physical Properties PUSA-076-02-01 02/22/2008 PRI (TST 5878) Physical Properties PUSA-083-02-01 04/14/2008 PRI (TST 5878) Physical Properties PUSA-088-02-01 07/29/2009 MTI (TST 2508) Physical Properties JX20H7A 04/01/2008 MTI (TST 2508) Physical Properties RX14E8A O1/29/2009 ERD (TST 6049) Physical Properties 11752.09.99-1 02/08/2000 ERD (TST 6049) Wind Uplift 11776.06.02 01/16/2003 ERD (TST 6049) Physical Properties 02200.07.03 07/14/2003 ERD (TST 6049) Wind Uplift P1740.01.07 01/04/2007 ERD (TST 6049) Physical Properties P5110.04.07-1 04/11/2007 ERD (TST 6049) Wind Uplift P9260.03.08 03/21/2008 ERD (TST 6049) Physical Properties P13450.08.09 08/13/2009 ERD (TST 6049) Wind Uplift P30540.11.09-111 11/30/2009 ERD (TST 6049) Physical Properties P33360.06.10 06/25/2010 Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R11 Certificate of Authorization #9503 FL5259-1116 Revision 11: 08/17/2012 Page 2of10 Entity ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ICC-ES (EVL 2396) Miami -Dade (CER 1592) Polyglass USA Polyglass USA Polyglass USA UL, LLC. (QUA9625) 4. PRODUCT DESCRIPTION: 4( I�RIN{IY i ERD Examination Reference Date Physical Properties P33370.03.11 03/02/2011 Physical Properties P33370.04.11 04/26/2011 Physical Properties P40390.08.12-1 08/06/2012 Physical Properties P40390.08.12-2 08/07/2012 IBC Compliance ESR-1697 11/01/2011 HVHZ Compliance NOA Current Manufacturing Affidavit Products Current 02/18/2009 P/L Affidavit Mule -Hide Cross Ltg 03/01/2008 Materials Affidavit Polystick SA Compound 08/18/2011 Quality Control Service Confirmation Exp. 08/08/2015 4.1 Mechanically Fastened Underlayments: 4.1.1 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet. 4.1.2 Elastobase P is a polyester -reinforced, SBS modified bitumen base sheet. 4.2 Self -Adhering Underlavments: 4.2.1 Polystick MTS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced with polyolefinic film surface; meets ASTM D1970 and TAS 103. 4.2.2 Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an aggregate surface; meets ASTM D1970. 4.2.3 Polystick TU is a nominal 100-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a granular surface; meets ASTM D1970 and TAS 103. 4.2.4 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a polyester fabric surface; meets ASTM D1970 and TAS 103. 4.2.5 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass- fiber/polyester reinforced, with a granular surface; meets ASTM D1970 and TAS 103. 4.2.6 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 170 g/m2 polyester fabric surface; meets TAS 103. 4.2.7 Polyflex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) are a polyester reinforced, APP modified bitumen cap sheets. 4.2.8 Dual PrOTM is a nominal 60-mll thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface. 4.2.9 Tile PrOTM is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface. 4.3 Mechanically Fastened and/or Bonded Underlavments: 4.3.1 Elastoflex S6G and Elastoflex S6G FR are polyester reinforced, SBS modified bitumen cap sheets. 4.3.2 Polyflex G and Polyflex G FR are polyester reinforced, APP modified bitumen cap sheets. 5. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVHZ. 5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R11 Certificate of Authorization #9503 FL5259-1116 Revision 11: 08/17/2012 Page 3of10 TRINITY I ERD 5.3 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the AHJ for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.4 Allowable roof covers applied atop the underlavments are as follows: Table 1: Roof Cover Options Underlayment Asphalt Shingles Nail -On Tile Foam -On Tile Metal Wood Shakes & Slate Shingles Elastobase Yes Yes No Yes Yes Yes Elastobase P Yes Yes No Yes Yes Yes Polystick MTS Yes Yes No Yes Yes Yes Polystick IR-Xe Yes No No No Yes Yes Polystick TU Yes Yes es No Yes Yes See 5.Polystick TU P Yes Yes Yes See 5.4.1 No Yes Yes Polystick TU Plus Yes Yes Yes See 5.4.1 Yes Yes Yes Polystick TU Max No Yes Yes No No No See 5 4.1 Dual Pro Yes Yes No Yes Yes Yes Tile Pro Yes Yes See a 4.1 Yes Yes Yes Elastoflex S6G or S6G FR Yes Yes No No Yes Yes Polyflex G or G FR Yes' Yes es No Yes Yes See 5.Polyflex SAP or SAP FR Yes Yes See es 5.Mule-Hide No Yes Yes SA-APP Cap Sheet Yes Yes Yes No Yes Yes or SA-APP Cap Sheet (FR) See 5.4.1 5.4.1 'Foam -On Tile" is limited to use of the following Approved tile adhesives unless tensile adhesion / long term aging data from an accredited testing laboratory is provided. ➢ Polyfoam PolyPro AH160: Polystick TU, Polystick TU P, Polystick TU Plus, Polyflex G, Polyflex G FR, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule - Hide SA-APP Cap Sheet (FR) or Tile Pro. ➢ 3MTm 2-Component Roof Tile Adhesive AH-160: Polystick TU Max ➢ Dow TileBond: Polystick TU P, Polystick TU Plus, Polyflex SAP or Tile Pro 5.4.2 For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the tile. 5.4.3 A 2-ply underlayment system, consisting of Polystick MTS followed by Polystick MTS, TU, TU P, TU Plus or TU Max, or Polyflex SAP is allowable for use under mechanically attached prepared roof systems. This is not a requirement, but is allowable if a 2-ply underlayment system is desired. Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1111 Certificate of Authorization #9503 FLS2S9-R16 Revision 11: 08/17/2012 Page 4 of 10 -J TRINITY ERa 5.5 Allowable substrates are noted below: 5.5.1 Direct -Bond to Deck: Polystick, Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: ➢ New untreated plywood; ➢ ASTM D41 primed new untreated plywood; ➢ Existing plywood; ➢ ASTM D41 primed existing plywood; ➢ ASTM D41 primed OSB; ➢ Southern Yellow Pine; ➢ ASTM D41 primed Southern Yellow Pine; ➢ ASTM D41 primed structural concrete; ➢ Huber Engineered Woods "ZIP System" Panels (designed and installed to meet wind loads for project). Note: Polyglass does not require priming of new or existing plywood sheathing. New or existing plywood sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes. Elastoflex S6G or S6G FR in hot asphalt to: ➢ ASTM D41 primed structural concrete. Polyflex G or G FR torch -applied to: ➢ ASTM D41 primed structural concrete. 5.5.2 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI 07320 does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI 07320 and are used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609.1.5 for determination of design wind pressures. 5.5.2.1 Maximum Design Pressure = -622.5 psf. Deck: Structural concrete to meet project requirements to satisfaction of AHJ. Primer: ASTM D41 Underlayment: Polyflex G or G FR torch -applied. 5.5.2.2 Maximum Design Pressure = -315 psf. Deck: Structural concrete to meet project requirements to satisfaction of AHJ. Primer: ASTM D41 Underlayment: Polystick TU, Polystick TU P, Polystick TU Plus, Polystick TU Max, Tile Pro, Polyflex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR). 5.5.2.3 Maximum Design Pressure = -135 psf. Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ. Primer: (Optional) ASTM D41 Joints: Min. 4-inch wide strips of Elastoflex SA-V over all plywood joints. Underlayment: Polystick TU, Polystick TU P, Polystick TU Plus, Polyflex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1111 Certificate of Authorization #9503 F1_5259-1116 Revision 11: 08/17/2012 Page 5 of 10 �. TRINITY I ERA 5.5.2.4 Maximum Design Pressure = -90 psf. Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ. Primer: (Optional) ASTM D41 Underlayment: Polystick TU, Polystick TU P, Polystick TU Plus, Polyflex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) 5.5.2.5 All other direct -deck, adhered Polyglass underlayment systems beneath foam -on tile systems carry a Maximum Design Pressure of -45 psf. 5.5.3 Bond -to -Insulation: ➢ Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: ASTM C1289, Type II, Class 1 polyisocyanu rate or Type V polyisocyanurate-composite insulation; DensDeck DuraGuard; DensDeck Prime; or SECUROCK Gypsum -Fiber Roof Board. ➢ Elastoflex S6G or S6G FR in hot asphalt to: DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board. ➢ Polyflex G or G FR torch -applied to: ASTM D41 primed structural concrete; DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4470, Appendix K or TAS 114, Appendix J. 5.5.4 Bond to Mechanically Attached Base Layer: ➢ Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or Tile Pro self -adhered to: ASTM D226, Type I or II felt; Elastobase; Elastobase P or Mule -Hide Nail Base. ➢ Elastoflex S6G or S6G FR in hot asphalt to: ASTM D226, Type I or II felt; Elastobase; Elastobase P or Mule -Hide Nail Base. ➢ Polyflex G or G FR torch -applied to: Elastobase; Elastobase P or Mule -Hide Nail Base. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam -on tile systems, base layer shall be attached per minimum requirements of FRSA/TRI 07320/8-05 or RAS 120. 5.6 Exposure Limitations: 5.6.1 Elastobase, Elastobase P, shall not be left exposed for longer than 30-days after installation. 5.6.2 Polystick IR-Xe, Polystick TU Max, Dual Pro or Tile Pro shall not be left exposed for longer than 90-days after installation. 5.6.3 Polystick MTS, TU, TU P or TU Plus shall not be left exposed for longer than 180-days after installation. 5.6.4 Polyflex SAP or SAP FR, or Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure limitation, unless the prepared roof covering is to be adhesive -set tile, in which case the maximum exposure is 30 days. 5.6.5 Elastoflex S6G or S6G FR or Polyflex G or G FR does not have an exposure limitation, unless the prepared roof covering is to be adhesive -set tile (Polyflex G or G FR only), in which case the maximum exposure is 180 days. Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R11 Certificate of Authorization #9503 FL5259-1116 Revision 11: 08/17/2012 Page 6 of 10 ­-J TRINITY 1 ERD 5.7 For tile roof installations governed by the FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, use is limited to the following. Reference is made to the FRSA/TRI Technical Brief titled "Florida High Wind Roof Tile Self -Adhered Underlayment Requirements as of 02/14/2011" for limitations for self -adhering underlayments used beneath tile roof systems. Table 2: Tile System Options per FRSA/TRI 07320/8-05 System Underlay Option Section Reference Product(s) 3.02A 1 Batten Modified Cap Sheet Elastoflex S6G or Elastoflex S6G FR; Polyflex G or G FR only No. 30 / Modified Cap Base Layer: Elastobase; Elastobase P System One: 2 3.02B Sheet Top Layer: Elastoflex S6G or Elastoflex S6G FR; Polyflex G Mechanically or G FR 4 3.021) No. 30 Elastobase; Elastobase P Fastened Tile, Unsealed or Sealed Self -Adhered Polystick MTS; TU; TU P; TU Plus; TU Max; Polyflex SAP or Underlayment 5 3.02E Underlayment SAP FR; Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR); Dual Pro; Tile Pro System Base Layer: ASTM D226, Type II; Elastobase; Elastobase P; No. 30 / Self -Adhered Mule -Hide Nail Base 6 3.02F Underlayment Top Layer: Polystick MTS; TU; TU P; TU Plus; TU Max; Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA- APP.Cap Sheet (FR); Dual Pro; Tile Pro 3.02A 1 Batten Modred Cap Sheet Elastoflex S6G or Elastoflex S6G FR; Polyflex G or G FR only No. 30 /Modified Cap Base Layer: Elastobase; Elastobase P System Two: 2 3.02B Sheet Top Layer: Elastoflex S6G or Elastoflex S6G FR; Polyflex G Mechanically or G FR Fastened Tile, Self -Adhered Polystick TU; TU P; TU Pius; TU Max; Polyflex SAP or SAP Sealed 4 3.02D aymen Underit FR; Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet Underlayment (FR); Dual Pro; Tile Pro System Base Layer: ASTM D226, Type II; Elastobase; Elastobase P; No. 30 / Self -Adhered Mule -Hide Nail Base 5 3.02E Underlayment Top Layer: Polystick TU; TU P; TU Plus; TU Max; Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro; Tile Pro 1 3.02A Modified Cap Sheet Polyflex G or G FR 2 3.02B No. 30 / Modified Cap Base Layer: Elastobase; Elastobase P System Four Sheet Top Layer: Polyflex G or G FR Self -Adhered Polystick TU; TU P; TU Plus; TU Max; Polyflex SAP or SAP 'W': Adhesive -Set 4 3.021) Underlayment FR; Tile Pro; Mule -Hide SA-APP Cap Sheet or SA-APP Cap Tile, Unsealed or Sheet (FR) Sealed Underlayment Base Layer: ASTM D226, Type II; Elastobase; Elastobase P; System 5 3.02E No. 30 / Self -Adhered Mule -Hide Nail Base Top Layer: Polystick TU; TU P; TU Plus; TU Max; Polyflex Underlayment SAP or SAP FR; Tile Pro; Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) 1 3.02A No. 30 / Modified Cap Base Layer: ASTM D226, Type II; Elastobase; Elastobase P Sheet Top Layer: Polyflex G or G FR Self -Adhered Polystick TU; TU P; TU Plus; TU Max; Polyflex SAP or SAP System Four "B": 3 3.02C Underlayment FR; Tile Pro; Mule -Hide SA-APP Cap Sheet or SA-APP Cap Adhesive -Set Sheet(FR) Tile, Sealed Base Layer: ASTM 13226, Type II; Elastobase; Elastobase P; Underlayment Mule -Hide Nail Base System 4 3.021) No. 30 / Self -Adhered Underlayment Top Layer: Polystick TU; TU P; TU Plus; TU Max; Polyflex SAP or SAP FR; Tile Pro; Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Exterior Research and Design, LLC. Certificate of Authorization #9503 Evaluation Report P12060.02.09-1111 FL5259-R16 Revision 11: 08/17/2012 Page 7 of 10 r� TRINITY I ERD 6. INSTALLATION: 6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 Elastobase, Elastobase P or Mule -Hide Nail Base: 6.3.1 Shall be installed in compliance with the codified requirements for ASTM D226, Type II underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.3.2 For use in non -tile applications: 6.3.2.1 Reference is made to the current edition of the NRCA Steep -slope Roofing Manual and ARMA recommendations for installing shingle underlayments and flashings 6.3.2.2 Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), Dual Pro or Tile Pro, self -adhered, Elastoflex S6G or S6G FR in hot asphalt or Polyflex G or G FR, torch applied. 6.3.3 For use in tile applications, reference is made to Polyglass published installation instructions in conjunction with FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein. 6.4 Polvstick MTS, IR-Xe, TU, TU P, TU Plus, TU Max Polvflex SAP or SAP FR, Mule -Hide SA-APP Can Sheet or SA-APP Cat) Sheet (FRI, Dual Pro or Tile Pro: 6.4.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.4.2 For non -tile applications: 6.4.2.1 All self -adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) should be back -nailed in selvage edge seam in accordance with Polyglass / Mule -Hide Back Nailing Guide. Nails shall be corrosion resistant, 11 gauge ring -shank type with a minimum 1-inch diameter metal disk or Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back - nailed using the above noted fasteners and spacing, in area marked "nail area, area para clavar" on the face of membrane. The head lap membrane is to cover the area being back - nailed 6.4.2.2 All seal -lap seams (selvage laps) must be firmly rolled with a minimum 28 lb. hand roller to ensure full contact and adhesion. For Dual Pro and Tile Pro, align the edge of the top sheet to the end of the glue pattern (the sheet will overlap the fabric). Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1111 Certificate of Authorization #9503 FL5259-R16 Revision 11: 08/17/2012 Page 8of10 t TRINITY ERD View of Ovelap Seam of Dual Pro and Tile Pro 6.4.2.3 All over -fabric and over -granule end -laps shall have a 6-inch wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Polystick TU Plus Tile Underlayment Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Electrometric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic, applied in between the application of the lap. 6.4.2.4 Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details 6.4.2.5 Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Polystick TU Plus Tile Underlayment Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic to the area in need of repair, followed by a minimum 6 x 6 inch patch of the Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be installed in a water shedding manner. 6.4.2.6 All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a minimum of 40-lb weighted -roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied for the field membrane. Hand rollers are acceptable for rolling of patches, laps (min. 28 lb roller) or small areas of the roof that are not accessible to a large roller or broom. 6.4.3 For tile applications (not allowed for Polystick IR-Xe): 6.4.3.1 Reference is made to Section 6.4.2 herein in conjunction with FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein, using the instructions noted above as a guideline. 6.4.3.2 For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the tile. Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R11 Certificate of Authorization #9503 FL5259-1116 Revision 11: 08/17/2012 Page 9 of 10 �\TRINITY 1 ERD 6.5 Elastoflex S6G or S6G FR: 6.5.1 Elastoflex S6G or S6G FR shall be installed in compliance with current Polyglass published installation requirements. For use in nail -on tile applications, reference is made to FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein. 6.5.2 Elastoflex S6G or S6G FR shall be fully asphalt -applied to the substrates noted in Section 5.5. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, and off set end -laps minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge. 6.6 Polvflex G or G FR: 6.6.1 Polvflex G or G FR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications, reference is made FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein. 6.6.2 Polyflex G or G FR shall be fully asphalt -applied to the substrates noted in Section 5.5. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, and off set end -laps minimum 3 feet from course to course. Side and end laps shall be fully heat -welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap edge. 6.7 Tile Staging: 6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to Polyglass published requirements for tile staging.. 6.7.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TRI 07320/8- 05 must be used on all roof slopes greater than 7:12. For roof slopes in excess of 61/4:12, precautions should be taken, such as the use of battens, to prevent tile sliding during the loading process. 6.7.3 For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the tile. 6.7.4 The minimum cure time after installation of self -adhering membranes and before loading of roofing tiles is forty-eight (48) hours. 7. LABELING: Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. S. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL, LLC — QUA9625; (314) 578-3406; k.chancellor@us.ul.com - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1111 Certificate of Authorization #9503 FL5259-1116 Revision 11: 08/17/2012 Page 10 of 10