HomeMy WebLinkAboutSUBMITTED PAPERSF/
OFFICE USE OLV Y:
DATE FILED DTI 1 %3 q� 6
PLAN REVIEW FEE: 160.0 0 RECEIPT NO..' PERMIT NUMBER: 134 k -QQ 54
CONCURRENCY FEE: RECEIPT NO.: CERT. CAP. NO.:
ALL INFO MUST BE COMPLETE & FILLED IN TO BE ACCEPTED
` J u PLANNING & DEVELOPMENT SERVICES DEPARTMENT
® BUILDING & CODE REGULATIONS DIVISION
® 2300 Virginia Avenue
Ft. Pierce, FL 34982-5652 �G''1
,772-462-1553 �t e� F®
43 -10 MG r=M5,
APPLICA`r O for my
N o BUILDING PERMIT
CERTIFICATE of CAPACITY/ZONING COMPLIANCE
P
PROJECT INFORMATION
1. LOCATION/SITE ADDRESS:
2. PROJECT NAME: ��es j" � v s SITE PLAN NAME: i e
3. PROPERTY TAX ID #: 4/ 0 3 S� va — O 13 9 — o 0 0 - d
4. LEGAL DESCRIPTION (attach extra sheets if necessary): Z,077) 1.✓� , `f c G ,'¢ �� /,,1, r., 5.'v r'�
5. PLAT BOOK Ic 6. PAGE NO. 23 7. BLOCK NO. 8. LOT NO. —2 7
9. PARCEL SIZE (ACRES/SQ FT.): LOT DIMENSIONS: 6 Y 3 •
10, COMPLETE DESCRIPTION OF CONSTRUCTION PROJECT OR WORK ACTIVITY:
v S C
IS A C
11. SETBACKS (ACTUAL) FRONT; / BACK: z% ' RIGHT SIDE: 3. �' LEFT SIDE: Sy9
i io
12. TYP OF CONSTRUCTION (Check all appropriate boxes)
[ W CONSTRUCTION [ ] EXPANSION/ADDITION [ ] INTERIOR RENOVATION
[ ESIDENTIAL [ ] COMMERCIAL [ ] INDUSTRIAL
[ ] OTHER (SPECIFY)
13. DESCRIPTION OF PROPOSED USE: oues � "�d v s e
14. SQ. FT OF CONSTRUCTION: (/ 15. SF. FT Ist FLOOR:
7�
16. VALUE OF CONSTRUCTION: $
The value of construction is used to determine the amount of permit fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated
value of construction if it is demonstrated that the submitted figures arc not consistent with similar types of construction activities. If the valucis $2500 or more, a
RECORDED Notice of Commencement must be submitted with this application.
0
SLCCDV Form No.: 001-02
le-C VPLU6 �9, yaz%
UPDATED 6/25/09
.01
OWNER INFORMATION ,
NAME: Le �'2 S bird /-/p //D U.V
ADDRESS: ;tr-7� 7 G / , i► %Z _ -
CITY: STATE: ZIP:y sf/
PHONE (DAYTIME): Email: S %9d yg lVo //c> u/- 4P c/a AOd.- C�
IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE, PLEASE
FILL IN NAME AND ADDRESS BELOW.
FEE SIMPLE TITLEHOLDER:
ADDRESS:
CITY: STATE: ZIP:
PHONE (DAYTIME): L_)
CONTRACTOR INFORMATION
ST. of FL REG.CERT #:
BUSINESS NAME:
QUALIFIERS NAME:
ADDRESS:
CITY:
PHONE (DAYTIME): (__)
STATE:
FAX NO.
ST. LUCIE COUNTY CERT #:
ARCIUVENGINEER: r-vOK C'-' 1 d lML' ll c�-'-d
Email:
ZIP:
ADDRESS: 806 A / 6 _
CITY: &. i -el-e-' STATE: %'/ ZIP: 3 V g S U
PHONE (DAYTIME): (ice '1G D -? % 57/
BONDING COMPANY:
ADDRESS:
CITY:
STATE:
ZIP:
MORTGAGE LENDER:
ADDRESS:
CITY: STATE: ZIP:
IMPORTANT NOTICE: When a permit is issued and it is not picked up within 60 days after notification
it will be voided and returned to you by mail.
i
Awk
OFFICE USE ONLY BP #:
SECTION
TOWNSHIP
`Z!�6
RANGE(40
MAP NO.
3
ZONING
LAND USE
LOT CVG %
TAZ NO.
FLOOD ZONE
FIRM MAP #
<
1ST FLR ELV
MAX HGT
CONST TYPE
OCCUP TYPE
MAX OCCUP
# OF FLRS
WATER
wet `
SEWER
SPRINKLERS
STORMWATER
LOT OF REC
LOT OF REC
LOT SPLIT
LOT SPLIT
Before 1/1990
After 1/1990
REQUIRED
APPROVED
REPORT
HABITABLE
RADON
PERMIT
CODE
I:.�
AREA
FEE
FEE
RADON)
LIBRARY
PUBLIC BLD
PUBICIJLD
PARKS
IMPACT
IMPACT FEE
CT
IMPACT
FEE
CORRECTION
FEE
FEE
GENERAL
SCHOOL
ROAD
CREDIT
Y
N
LAW ENF
IMPACT
IMPACT
IMPACT
FEE
FEE
FEE
/Y
FIRE/EMS
IMPACT
DRIVEWAY
REQUIRED
(�1
N
DRIVEWAY
FEE
ADMINISTRATIVE
VARIANCE FEE
FEE
SPECIFY
MECHANIC ROOF
NON -CONFORMING
MISCELLANEOUS
SUBS
7,,
ELECTRIC ice! ^ GAS +/
LOT OF RECORD
FEES
REQUIRED
PLUMBING V
FEES
DATE SENT TO ADDRESSING: /
REVIEWS
FRONT
ZONING
SUPERVISOR
PLANS
VEGETATION
SEA TURTLE
MANGROVE
CO R
REVIEW
REVIEW
REVIEW
REVIEW
REVIEW
DATE
�jREVIEW
f Ub'
J
RECEIVED
I
q
U
DATE
1
I
-
/d
COMPLETEDl
�i1
d
INITIALS
r
t
CERTIFICATION:
This application is hereby made to obtain a permit to do the work and installations as indicated, and to obtain a certificate of capacity,
if applicable, for the permitted work. I certify that no work or installation has commenced prior to the issuance of a permit and that all
work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits
may be required for ELECTRICAL, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS,
AND AIR CONDITIONERS, FENCES, ETC., not otherwise included with this building permit application.
St. Lucie County makes no representation that its granting of a permit will authorize the permit holder to build the subject structure
which is in conflict with any applicable Homeowner Association rules, bylaws or any covenants that may restrict or prohibit such
structure. Please consult with your Homeowner's Association and review your deed for any restrictions which may apply.
The following building pen -nit applications are exempt from undergoing a full concurrency review: room additions, accessory
structures (all types), swimming pools, fences, walls, signs, screen rooms, utility substations & accessory uses to another non-
residential use.
NOTICE TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOBSITE BEFORE THE
FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR
LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF
COMMENCEMENT.
NOTICE TO APPLICANT: IF IT IS NOT YOUR RIGHT, TITLE, AND INTEREST THAT IS SUBJECT TO
ATTACHMENT: AS A CONDITION OF ISSUANCE OF THIS PERMIT, YOU PROMISE IN
GOOD FAITH TO DELIVER A COPY OF THE CONSTRUCTION LIEN LAW NOTICE TO
THE PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT.
Z"' A -
OWNER OR CONTRACTOR SIGNAXME
STATE OF FLORIDA STATE OF R
COUNTY OF 51, 6,.) COUNTY OF
The foregoing instrument was acknowledged before
me this day f y /'1 _ 20 /3
/ r
by 5 a-/ d
who ' ersonally known or has produced
R SIGNATURE
The foregoing instru ne t was acknowledged before
me this day of
by
who is personally known o has produced
identification.
Sig of N Signature of Notary
• `,,. 'V �YVB iI
' LISA L. WNi"IE
Commission No �4/ .••'��, �$ral�otary Public - State of Florida omtnission No. (Seal)
MY.Comm. Expires Dec 8, 2014
Commission N EE 48013
Bonded Through Nauonal Notary Assn.
NOTE: TWO (2) SIGNATURES E TURE MUST BE NOTARIZED. IF APPLYING FOR
THIS BUILDING PERMIT AS AN-OWNER/BUILDER, THE OWNER MUST PERSONALLY APPEAR "TO SIGN
THIS APPLICATION -IN THE OFFICE LISTED ON THE FRONT OF THIS APPLICATION.
OWNER BUILDER AFFIDAVIT WILL BE REQUIRED FOR ALL OWNERBUILDER APPLICANTS. '
For specific instructions see appropriate permit checklist.
- Termite Inspection
Termite Pretreatment,
• Pest Control
• Rodent Service
• Fire Ant Lawn Service
•L' d&1 d
0
Jesus Christ is Lr
jr
® hict-A-Rug
iE Termite'.' & Pest
Control
W Inc.
72m323®7921
Faar 772-349-5999
Email: Evictabug@gmail.com
2373 SW Woodridge St.
icense nsure Lic. JB175775 Port St. Lucie FL. 34953
Notice of Preventative Treatment for Termites
(as required by Florida Building Code (FBC) 104.26 and Broward County Chapter FBC 105.2.2)
PEST PREVENTION I FIRE ANT SERVICE I TERMITE SERVICE I RODENT EXCLUSION & REMOVAL
DATE OF SERVICE �i ' �'I 'SG� TIME 3 U
DEVELOPMENT NAME -(PROJECT) CONTRACTOR'S NAME CONTACT PERSON
AMPS
STRUCTURE ADDRESS (]-& BL�CK) CITY, STATE, ZIP CODE-,, f ' COUNTY
Al
NOTES
-?C"'PM 1 7- 0 f-3 C 5-5"'
*T1
TREATMENT TYPEIAREA
❑ FLOATING ❑ MONOLITHIC ❑ PATIO ❑ GARAGE ❑ DRIVEWAY ❑ STEM WALL ❑ ADDITION
❑ CUTOUTS ❑ FOOTER ❑ FRONT ENTRY ❑ RETREAT ❑ BORA CARE TREATMENT ❑ PLUMBING CUT OUTS
❑ TAMP & TREAT WREAT ONLY P�TINAL ❑ POOL DECK ❑ OTHER
PRODUCTS
'6 ASELINE ❑ DOMINION 2LACTIVE INGREDIENT 111'BIFENTHRIN ❑ TERMIDORTC ❑ BORACARE
❑ OTHER
ACTIVE INGREDIENT
CONCENTRATION
(916% ❑ .12% ❑ .25%a
SQUARE FOOTAGE
SQUARE FOOTAGE VERIFIED
❑ YES ❑ NO
JOB READY CONDITIONS MET
OYES ❑ NO
❑ DISODIUM OCTABORATE TETRAHYDRATE
❑ .05% ❑ 23% ❑ 9% ❑ OTHER "GALLONS APPLIED I 10
pLINEAR FOOTAGE 10
. MEASURED ASURED OR VERIFIED PER PLANS
DETAILS'
As per 104.2.6 FBC - If soil chemical barrier method for termite prevention is used. Final exterior treatment shall be completed prior to final building approval.
Certificate of Compliance: The building has received a complete treatment for the prevention of subterranean termites. Treatment is in accordance with rules and laws established
by the Florida Department of Agriculture and Consumer Services. (Per the Florida Building Code.)
If this notice is for the final exterior treatment, initial an(
FINAL -STICKER
ELECTRICAL PANEL ❑ WATER HEATER
�r
Payment Terms: Payment due at time of service.
0111-
Date
b��l
Date
uuswmer trropeny Owner or Hyeny
KSM
KELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, INC.
MARTIN (772) 337-7755 PO. BOX 78-1377, SEBASTIAN, FL-32978-1377 SEBASTIAN (772) 589-0712
PALM BEACH (561) 845-7445 www.ksmengineering.net MELBOURNE (321) 768-8488
FAX (561) 845-8876 E-Mail: KSM@KSMENGINEERING.NET ST. LUCIE (772) 229-9093
C.A.: 5693 FAX (772) 589-6469
DATE TESTED
PERMIT #
CONTRACTOR
JOB LOCATION
SOIL COMPACTION REPORT
ASTM D 1557 and ASTM D 2922
February 19, 2013
1301-0054
Lewis Holloway
4776 Dunn Road
Fort Pierce, Florida
ITEM TESTED Compacted Foundation Fill for Guest House
KSM JOB # : 130280-1 d/ES/km
FE8 2 6 2013 D
a
TEST LOCATION
'OF
* PEN
DEPTH
DRY
MAX. DRY
PERCENT
SAMPLE
READ
DENSITY
PROCTOR VALUE
COMPACTION
1.
N.E.
0" - 12" 40
112.1
114.1
98.2
2.
N.W.
48
113.4
of99.4
3.
S. E.
52
111.9
98.1
4.
S.W.
48
112.4
98.5
Soil Description: "
Dark Gray Slightly Clayed Sand
In Place Moisture:
7.5 Percent
Optimum Moisture:
10.4 Percent
Max. Dry Density:
114.1 P.C.F.
@ Test Locations The
Density & Penetrometer
Readings Indicate the
Megree�tf�Rgction Meets
P n. eadin Taken ri Natural Grade.
r
R I u m1
116.01 1 1 1 1 1 1
W
.E I I I I
G115.0 .---�----I--------;--- ---� — --
H I I I I I I
T
114.0 }----f----I-- -----1----f— -
P
I I I I I I I
C I I I I I I
113.0 --- --- ------ ---- -•-- -
F I I I I I I
I I I I I I I
D I I I I I I I
R
Y I I I I I I I
7 8 9 10 11 12 13 14
�icie County Building Department
oway@yahoo.com
Moisture - % of Dry Weight
Ronald G. Keller, P.E.: 37293 / SI Lic. No.: 860 / Julie E. Keller, P.E.: 68366
02/20/2013 23:06 77258964 K.S.M.ENG. PAGE 01/01
KSM
KELLER, SCHLEICHER & MacWILLIAM ENGINEERING ANDTESTING, , G-
MARTIN (772) 337-7755 PO, BOX 78-1377, SEBASTIAN, FL 32978-1377 ME BASTINE (3AN 71) 589-0712
PALM BEACH (661) 845-7445 www.ksmengineering.net $T. UR E (321) 229-8488
FAX (561) 845-8878 E-Mall: KSMOKSMENGINEERINC.NEt FAX (772) 589-6469
C.A.: 5693
SOIL COMPACTION REPORT
ASTM D 1557 and ASTM D 2922
DATE TESTED
February 19, 2013
KSM JOB # : 130280-1 d/ESlkm
PERMIT #
1301-0054
CONTRACTOR
Lewis Holloway
JOB LOCATION
4776 Dunn Road .
Fort Pierce, Florida
ITEM TESTED
Compacted Foundation Fill for Guest House
TEST LOCATION
*PEN
DRY
MAX. DRY PERCENT
OF SAMPLE
DEPTH
READ
DENSITY
PROCTOR VALUE COMPACTION
1. N.E.
0" - 12" 40
112.1
114.1 98.2
2. N.W,
it 48
113A
it 99.4
if 98.1
3. S.E.
52
111.9
It98.5
4. S.W.
it 48
112.4
Soil Description:
Dark Gray Slightly Clayed Sand
In Place Moisture:
7.5 percent
Optimum Moisture:
10.4 Percent
Max. Dry Density:
114.1 P.C.F.
@ Test Lo.cations The
Density & Penetrometer
Readi Ate the
p ' on Meets
*Pent -Wigs Tak
Ides a miff
S1 F, O!'
F I
v
-mail tarlvinhc
Natural Grade.
Lucie County Building Department
Iloway@yahoo.com
Moieture - % of Dry Weight
RECEIVED FEB 219013
Ronald G- Keller, P.E 37293 / SI Lie. No.- 860 1 Julie E. Keller, P.E.: 68366
Planning 8 Development Services
Building & Code Regulation Division
Permitting Department
2300 Virginia Avenue
Fort Pierce, FL 34982
01 /29/2013
LEWIS HOLLOWAY
4776 DUNN ROAD
FORT PIERCE, FL 34981=5031 ,
Review Comments for Owner
Page 1
Permit Number: 1301-0054
As of today's date your Contractor is' being notified along with yourself that the referenced building permit has some
issues listed in the comments below.
We have asked that these issues be dealt with as quickly as possible so that we are able to continue to process this
permit in a timely manner.
This information is being shared with you so you are aware of the status of your permit..
PROPERTY INFORMATION
4776 DUNN
FORT PIERCE 34981
APPLICATION INFORMATION
Permit Number: 1301-0054
Activity Type: New
Permit Type: BRG (Guest House)(214)
REVIEWS AND COMMENTS
Review Type Status
Documents Missing Pending
RD
CONTRACTORS INFORMATIOA
Application Type: Building Permit w/o subs
Other Activity:
Stories 1
Reviewed By Date Started Date Complete Date Released
Deanna Gvens
OIL
Planning & Development Services
Building & Code Regulation Division
Permitting Department
2300 Virginia Avenue
Fort Pierce, FL 34982
Review Comments for Owner-
Page 2
01/07/2013 1 Comment RLCURULU NU'I ICL OF UUMMLNUEMtN I
01/07/2013 2 Comment 1/17/13 VEG PERMIT IN DRAWER UNDER "H" FEES ARE LOADED
VEG PERMIT SENT TO ERD ON 01/07/13
01/10/2013 3 Comment SIGNTURE ON ENERGY CALCS AND DISPLAY CARD MISSING.
01/22/2013 4 Comment OWNER REQUIRED TO SIGN ALL SUB AGREEMENTS AT TIME OF PICKUP.
Review.Type Status Reviewed By Date Started Date Complete Date Released
Front Counter Review Complete Deanna Gvens 12/31/2012 01/07/2013
Review Type Status Reviewed By Date Started Date Complete Date Released
Plans Examiner Review Incomplete Dave Johnson 01/29/2013
01/29/2013 1 Comment AC PLAN MUST BE PROVIDED IN DUPLICATE. 107.2.1 FBC
01/29/2013 2 Comment PROVIDE PLUMBING RISER DIAGRAM IN DUPLICATE 107.2.1 FBC
01/29/2013 3 Comment POT FILLER ABOVE STOVE IS NOT ALLOWED P2702.1 FBC R
01/29/2013 4 Comment SHOW ATTIC ACCESS ON PLANS R 807.1
01/29/2013 5 Comment A SEPERATE GAS PERMIT WILL BE REQUIRED FOR GAS TANK INSTALLATION IF THERE IS NOT AN
EXISTING GAS SUPPLY
Review Type Status Reviewed By Date Started Date Complete Date Released
To Be Reviewed by Zoning Complete 01/10/2013
Review Type Status
To Be Review by Plans Exan Complete
Reviewed By
Review Type Status Reviewed By
Zoning Review Complete Lydia Galbraith
Date Started Date Complete Date Released
01/29/2013
Date Started Date Complete Date Released
01/10/2013 01/22/2013
� J}. _. .• YE, 1�)$';,� t'i'i � .pu i'tt^�..,���A✓"� �3�i``L�'�3�Y"P'��.."•Cy,�."+v.SWy�'-'!b'�t3'Z,py,�'p}�'\�. $�'�"w{".r��.'FI"e^% �ry"^�rv��.Pr W+-nq .YYu� ��`F'�"Y,t .G�i. fct irZ. "i'. t;/yT. i yT aN' �
s.� h-�A:. f.�i ::".�.k'.r�: ����:F �Y :T�. '� #`�y" y��� ��i e�:ft�'h'-e� f)�,FfSTf c�.M'S€'i+�,.�'����-a'.���tTi�"LN�:�ii^. i^�"��:5�� �'�..1 ��`Sf°� :q � �[j:w'�w• `$J yr./r4�'i'. �A'N" � � �34,' kf Y L_..
t. „Y�q.;ph+t*-. 'v a ,u^•wx trl p.:_' ...�r "•�s"f,.:.'�aa�;•2'.,.:{.SKi ,.` a s; rrs._. d...!:
ahanaP esrr nt i �ni e, he p�an.revieW�a complisfi& asp;
`umer.'"Is r rtt 1`•' tE�a� 67e d�4o of Elie 20b a? /fix
iadicaf n i i : .
u eW. d :.,.. zm�? y�r s . PP.[r .W �� ewe k` v f �:l M
,.inicate(.inrEh :Qcod�si ,. {e 32isodeseg�{gpsr�.aotfica d� ti lacf �p�`tifi7i_�e o•„rd eft ei�`cas�om�po�ry( �appDcbl�ecode&e�otidn§with wf3
. �- - u�vR.M�: sria'` tY%4'.t7�"e+; t' .,1,t,-- c' ;V^.: & �+:",•sY".s F>.rXi'..r'y? xr'?`Si r. �c, .i�i'=� "arha• t.a`E- .u. c'Y�r"`�r
tl.esr`e atd o atn� tl e '`• eta le''3 fiz r i'.o, Fii pfcal _ ouii`rm eons oft oaf eaS ortone farad two fatrtlj dwellings antl
gas . 5� :� -P r g;..5
to be used �y`i�ioseu�r
DU s lt•tls si of�eeaa'I��Cbe'powslansay�6ea •:bt io tij�{} U fangsl{�isXecpd3ls�esig�d ohly
.:;i"i..n"{Y " .r'x?�t,-,5` . d'.`-iLK��u . - r+'n""�Cu �t�.G't $3 �' •-Yt ^,.-"E' rai�41" t"r� hq''k`�..+�ti
,!IhAaeltnotledcJ�eabean apaBlautecer�i}�gc�iTnln�eCecttdndocu{e'nfsdeomplia�.-
u5��i..
-',fir„'. �;k4�1..1.if. i^}5�..I+.�A. _f'a?�i'f'�. � �`'✓t�u «��3tf�4 ...��"J�lfRE�C �M'
.,:�]•.�tYe F'? � JCaS�Nx�,�...'�.D'e�h`:- :�i. X:FS. . r� ..&Z..Y, r.3:Skh5!'.w.,..1� -
CORRECTION LIST
Code
No.
DESCRIPTION
Section "
Rt
D
Art AGENT /hlisT SIC^, FNE 6} G/gCG%S
J
C AN Ob/L�` AT Tim 6 Of Pici< c.e
C3?
Nf fiD A PLAY u PC I CA-7
3
P1zo01.04, Pc(i /A4.it.0 RUj(A ,o,A ,e--1.h
4
po7 f-/d4AA 94 a V Z .r7av—Z is A007 d4m,-7740'
P a7o
SHOt,V f1i%�c G s DA. .0c
qO)
A SE,-E/! A74' 46 mar r-
Fati G 91 TANK fi9c 47i��
\\ o� • li• o •.- � "-• •• • • • • o -m ISBN 978-1-58001-951-4
• • • . . - • w '. .
' o. •...
.. ® . • • .
mil♦ II I II II I I I it I II III I II III
'.
,
��••,� � ® 0 9II781580II019514II
e o
INTERNATIONAL w
CODECOUNCIL ® a i
t
06/10
CORRECTION LIST
Code
No. DESCRIPTION Section
-2-
NOTE: Entries to this Plan Review Record that require a field check or inspection of the installation must be coordinated with the Inspection phase (R109) of the project.
BUILDING PLANNING (Chapter 3)
DESIGN CRITERIA [Table R301 2(1)j &M Two-family dwelling separation (R302.3)
Floor live load (Table R301.5) ✓
psf
Roof live load (Table R301.6)
psf
Ground snow load N to
psf
Basic wind speed ✓
mph
Wind exposure category (R301.2.1.4)
High wind design criteria applicable /
(R301.2.1.1) l/
Seismic design category (SDC) N�Q
[Figure R301.2(2)]
SDC C&D provisions (R301.2.2)
Weathering �✓
Frost line depth
Termite area
Decay area N/A
Winter design temperature
Ice barrier underlayment required N/A
Flood hazards /V/9
FIRE-RESISTANT CONSTRUCTION (R302)
Exterior walls (R302.1, Table R302.1)
/ Townhouse separation (R302.2)
Continuity and structural .
independence (R302.2.1,
R302.2.4)
Parapets and construction
(R302.2.2, R302.2.3)
ROOM PLANNING REQUIREMENTS (R303 through R305)
/N 1.4
Dwelling unit penetrations (R302.4)
/SIX
Dwelling/garage opening/penetration protec-
tion (R302.5)
Dwelling/garage fire separation (R302.6)
Under -stair protection (R302.7)
Wall and ceiling finishes (R302.9)
Flame spread index (R302.9.1)
_Smoke -developed index
(R302.9.2)
Testing (R302.9.3, -R302.9.4)
r✓ Insulation 302.10)
Flame spread/smoke-developed
(R302.10.1, R302.10.2)
Cellulose loose -fill and exposed
attic insulation (R302.10.3,
R302.10.4)
Nl� Testing (R302.10.5)
%"'f to
Fireblocking (R302.11)
tA- �11'
Draftstopping (R302.12)
"'f ?
Combustible insulation clearance (R302.13)
Use
Area
ft2
Width
Average
ceilin t
Minimum
ceilin t
Natural*
light
Natural ventilation*
Living
120
7'-0"
7'-0"
F-0"
8% floor area
4% floor area
Dining
70
7'-0"
7'-0"
5'-0"
8% floor area
4% floor area
Kitchen
N.A.
N.A.
7'-0"
5'4"
8% floor area
4% floor area
Bedroom
70
7'-0"
7'-0"
5'4"
8% floor area
4% floor area
Bathroom
N.A.
N.A
7'70"
5'-0"
3 square feet
1 % square feet
* See Sections R303.1 & R303.3 for mechanical ventilation and artificial light
t 6'-8" min. at plumbing fixtures and for non -habitable basements.
✓ Required heating (R303.8)
SANITATION (R306 and R307)
Water closet
✓ Lavatory
✓ Tub or shower
Kitchen area with sink
Sanitary sewer (Chapter 30)
✓ Private disposal (Appendix 1)
GLAZING (R308)
Identification (R308.1)
/ 149 Louvered windows or jalousies (R308.2)
Human impact loads/hazardous locations
(R308.3, R308.4)
NAB Skylights and sloped glazing (R308.6)
-3-
BUILDING PLANNING (cont'd.)
GARAGES AND CARPORTS (R309)
Floor surface noncombustible; sloped floor
(R309.1)
Carport: open two sides; noncombustible
/ floors; sloped floor (R309.2)
Automatic garage door opener (R309.4)
EMERGENCY ESCAPE AND RESCUE OPENINGS
(R 310
77 Where required (R310.1)
&//'o Areas, height, width, operations (R310.1.1 -
R310.1.4)
N104' ' Window wells (R310.2)
I,/ /A Bars, grilles, covers and screens (R310.4)
Under decks and porches (R310.5)
MEANS QF EGRESS (R311)
General (R311.1)
Egress door (R311.2)
Landings at exterior doors (R311.3 -
R311.3.3)
A/ ('� Vertical egress (R311.4)
_ Construction and attachment (R311.5)
Hallways (R311.6)
4'�� Stairway width, headroom, walkline (R311.7.1
- R311.7.3)
Stairway treads, risers profiles (R311.7.4 -
R311.7.4.3)
-Stairway landings and walking surfaces
(R311.7.5, R311.7.6)
Handrails required (R311.7.7)
Handrail height, continuity, grip -size
(R311.7.7.1 - R311.7. 7.3)
Al
Stairway illumination (R303.6, R311.7.8)
IL"/A
Special stairways (R311.7.9)
1" N
Ramp slope, landings, handrails (R311.8)
GUARDS (R312)
%y1/4 Required for open -sided surfaces, stairs,
ramps and landings > 30" above
floor/grade (R312.1)
Height - 36" (R312.2)
11A Opening limitations (R312.3)
AUTOMATIC FIRE SPRINKLER SYSTEMS (R313)
Townhouses (R313.1),
U_ (�__ One- and two-family dwellings (R313.2)
SMOKE ALARMS (R314)
J Referenced standards (R314.1, R314.2)
Location and interconnection (R314.3)
Power source (R314.4)
CARBON MONOXIDE ALARMS (R315)
/`'(A New construction (R315.1)
/" 1-4 Existing construction (R315.2)
/✓ (.#4 Referenced standard (R315.3)
FOAM PLASTIC (R302.8, R316)
/A*e Labeling (R316.2)
Al Surface burning, thermal barrier, specific
approval (R316.3 - R316.7)
DECAY AND TERMITE PROTECTION
(R317 and R318)
y anProtection required (Table R301.2(1), R317.1,
R318.1)
/ A'sP Quality mark (R317.2 and R318.1.1)
SITE ADDRESS (R319)
Aolo.� Address numbers (R319.1)
ACCESSIBILITY (R320)
/""& Type B dwelling units applicable (R320.1)
ELEVATORS/PLATFORM LIFTS (R321)
^- Referenced standards (R321.1 - R321.3)
FLOOD -RESISTANT CONSTRUCTION (R322)
General (R322.1)
Hazard area and requirements (R301.2.4,
R309.3, R322.2, R322.3)
Design professional (R322.3.6)
STORM SHELTERS (R323)
t'� /0 General and referenced standard (R323.1)
-4-
FOUNDATIONS (Chapter 4)
MATERIALS (R402)
Wood foundations (R402.1)
Concrete, compressive strength (R402.2)
FOOTIN S (R403)
oil bearing value (R401.4, R403.1)
oting width (see page 5)
Footing edge thickness = 6" minimum; footing
projection = 2" minimum, but <_ footing
thickness (R403.1.1)
Footings in SDC C or D (R403.1.2, R403.1.Y
and R403.1.6.1)
r/✓Si
Depth below (outside) grade = 12" minim
but below frost line except for frost pro
tected footings.(R403.1.4, R403.1.4.1 and
1_'/A
R403.1.4.2)
Sill plate bolting in concrete/masonry ='/z" di-
ameter bolts, within 12" but not less than 7
bolt diameters from corner, 7" embedment
(R403.1.6)
�Sl
Footings adjacent to slopes (R403.1.7)
I(A
Frost protected shallow foundations (R403.3)
Footings for precast concrete foundation
(R403.4)
FOUNDATION WALLS (R404 - R406)
Masonry foundation walls (R404.1.1)
Wall height, unbalanced backfill, nominal
thickness (Tables R404.1.1(1) -
illv q R404.1.1(4), R404.1.5.1]
�09
Reinforcement size and spacing
(fables R404.1.1(2) - R404.1.1(4)]
Concrete foundation walls (R404.1.2)
Wall height, unbalanced backfill, nominal
thickness (Tables R404.1.2(2) -
R404.1.2(8), R404.1.5.2]
Horizontal and vertical reinforcement size and
spacing (Tables R404.1.2(1) - R404.1.2(8),
R404.1.2.2, R4.04.1.2.3.7]
Stay -in -place forms (R404.1.2.3.6.1)
SDC C and D provisions (R404.1.2.4,
R404.1.4)
Height above finished grade (R404.1.6)
plate size (R404.3)
Precast concrete foundation walls (R404.5)
Drains required if habitable or usable spaces
are below grade" (R405)
Soil class (Table R405.1)
Dampproofing if basements are below grade*
(R406.1)
Waterproofing if high water table* (R406.2)
" If uninhabitable, see Under -Floor Space (R408)
COLUMNS (R407)
Protection from decay or corrosion i(R407.1
and R407.2)
C Structural requirements (R407.3)
Anchorage (R407.3)
Wood columns (minimum 4" square) (R407.3)
Steel columns minimum 3" diameter, Sched-
ule 40 pipe) (R407.3)
TABLE R403.1
MINIMUM WIDTH OF CONCRETE PRECAST OR MASONRY FOOTINGS (inches)'
LOAD -BEARING VALUE OF SOIL s
1,500 2,000 3,000 >_ 4,000
Conventional light —frame construction
1 -story
12
12
12
12
2-story
15
12
12
12
3-sto
23
1.7
12
12
4-inch brick veneer over light frame or 8-inch hollow
concrete masonry
1-story
12
12
12
12
2-story
21
16
12
12
3-story
32
24
16
12
8-inch solid or f liv crouted masonry
1-sto ry
16
12
12
12
2-story
29
21
14
12
3-story
42
32
21
16
For SI: 1 inch = 25.4 mm, 1 pound per square foot = 0.0479 kPa
a. Where minimum footing width is 12 inches, a single wythe of solid or fully grouted 12—inch nominal concrete masonry units is permitted.
-5-
FOUNDATIONS (cont'd.)
UNDER -FLOOR SPACE (R408)
Ventilation (R408.1 and R408.2)
nted crawl space (R408.3)AZI/14—
Access (R408.4)
FLOORS (Chapter 5)
WOOD JOISTS AND GIRDERS (R502)
Species and grade (R502.1)
Joists — Sleeping areas, LL = 30 psf
[Table R502.3.1(1)]
Joists — Nonsleeping areas, LL = 40 psf
[fable R502.3.1(2)]
Cantilevered joists [Tables R502.3.3(1) and
R502.3.3(2)]
Girder spans and header spans for exterior
bearing walls [Table R502.5(1)]
Girder spans and header spans for interior
bearing walls [Table R502.5(2)]
Joists under bearing partitions (R502.4)
Bearing (1.5" minimum on wood or metal; 3" on
masonry or concrete) and lapped joists (3")
(R502.6, R502.6.1)
Lateral restraint and bridging (R502.7,
R502.7.1)
Drilling and notching (R502.8)
Fastening (R502.9)
Framing of openings (R502.10)
Wood trusses (R502.11)
Draftstopping (R502.12)
LUMBER FLOOR SHEATHING (R503.1)
Allowable span (Table R503.1)
End joints (R503.1.1)
WOOD STRUCTURAL PANEL SHEATHING (R503.2)
Grade (R503.2.1)
Thickness (R503.2.1)
Allowable spans [Tables R503.2.1.1(1) and
R503:2.1.1(2)]
Installation [Table 602.3(1)]
Removal of debris (R408.5)
Finished grade (R408.6)
Flood resistance (R408.7)
PARTICLEBOARD UNDERLAYMENT (R503.3)
Grade (R503.3.1)
Thickness (R503.3.2)
Installation [Table R602.3(1)]
TREATED -WOOD FLOORS (ON GROUND) (R504)
Base course: 4" thick with maximum 3/4"
gravel or 1/Z" crushed stone (R504.2.1)
Moisture barrier: placed over base course
(R504.2.2)
Materials (R504.3)
STEEL FLOOR FRAMING (R505)
Cold -formed steel; applicability limits; in -line
framing (R505.1)
Structural framing (R505.2)
Material (R505.2.1)
Identification (R505.2.2)
Corrosion protection (R505.2.3)
Fastening (R505.2.4)
Floor construction (R505.3)
CONCRETE FLOORS (ON GROUND) (R506)
Thickness: 31/2" minimum; Concrete strength
/ (R506.1)
y Support: prepared subgrade; maximum earth
fill = 8"; maximum sand or gravel fill = 24"
�R506.2.1)
Base course: 4" graded with 2" maximum
aggregate (R506.2.2)
Vapor retarder (R506.2.3)
Reinforcement support (R506.2.4)
M
WALL CONSTRUCTION (Chapter 6)
GENERAL (R609)
Design (R601.2)
Component and cladding wind loads
[Table R301.2(2)]
f— Vapor retarders (R601.3)
WOOD CONSTRUCTION (R602)
Construction [Figures R602.3(1) and
R602.3(2)]
Stud grade (R602.2)
r164
Exterior walls (R602.3)
Fla
Stud spacing [R602.3.1, Table R602.3(5)]
Interior load -bearing walls (R602.4)
Interior nonbearing walls: 2" x 3" at 24" o.c.
or 2" x 4" flat at 16" o.c. (R602.5)
f
Drilling and notching — studs (R602.6)
1't'f i
Drilling and notching — top plate (R602.6.1)
i as P
Headers [Tables R502.5(1), R502.5(2),
R602.7.2 and Figure R602.7.21
/Ns1' Fireblocking (R602.8, R302.11)
P115 i" Cripple walls (R602.9)
IV d Wall bracing, braced wall lines, lengths,
connections, support and joints (R602.10,
R602.10.1, R602.10.3, R602.10.6 -
R602.10.8)
Bracing based on wind speed
[Table R602.10.1.2(1)]
Bracing based on SDC [Table R602.10.1.2(2)]
ILO'/A Intermittent bracing methods (R602.10.2,
Table R602.10.2)
Continuous sheathing
(R602.10.4, R602.10.5)
Bracing for SDC C and D (R602.10.1.4.1,
R602.10.1.5, R602.11)
IV /1 Wall bracing for stone and masonry veneer
If (R602.12)
STEEL WALL FRAMING (R603)
General (R603.1)
/�Ew Structural framing (R603.2)
Material (R603.2.1)
Identification (R603.2.2)
Corrosion protection (R603.2.3)
Fastening (R603.2.4)
Wall construction (R603.3 - R603.5)
Headers (R603.6)
Studs, tracks and structural sheathing
(R603.7 R603.9).
SHEATHING (R604 and R605)
Wood structural panels (R604)
Particleboard (R605)
MASONRY CONSTRUCTION (R606 - R610)
/%
General design (R606)-
N f4
SDC C and D (R606.12)
Unit masonry (R607)
Multiple wythe masonry (R608)
Grouted masonry (R609)
f'9
Glass unit masonry (R610)
EXTERIOR CONCRETE WALL
CONSTRUCTION (R611)
Applicability (R611.2)
Concrete wall systems (R611.3)
Stay -in -place forms (R611.4)
Materials, construction details
(R611.5 - R611.10)
EXTERIOR WINDOWS & DOORS (R612)
l s General; window sills; performance; testing
and labeling (R612)
STRUCTURAL INSULATED PANEL WALL
CONSTRUCTION (R613)
Applicability (R613.2)
Materials (R613.3)
Wall panels, construction details (R613.4 -
R613.10)
-7-
WALL COVERING (Chapter 7)
INTERIOR WALL COVERING (R702)
Plaster material (R702.2)
Plaster support (R702.2.3)
Gypsum board material (R702.3.1)
Gypsum board support, application and
/
fastening (R702.3.2 - R702.3.8)
y
Ceramic tile (R702.4)
Other finishes (R702.5 and R702.6)
EXTERIOR WALL COVERING (R703)
Water -resistive barrier (R703.2)
Wood siding (R703.3)
Attachment and minimum thickness
(Table R703.4)
Wood shakes and shingles (R703.5)
r/ Exterior plaster (R703.6)
Stone & masonry veneer (R703.7 & Figure
R703.7); Steel angle lintels-4" minimum
bearing each end (R703.7.3)
%L 44 Veneer ties: #9 U.S. gage wire or #22 U.S.
gage by'/e" corrugated metal; 24" o.c.
maximum horizontal spacing; 2.67 square
feet maximum area supported (wind > 30 psf
and SDC C or D, maximum area = 2 square
feet) (R703.7.4.1)
Flashing (R703.7.5 and R703.8)
11L11A Exterior insulation and finish systems (R703.9)
_(Z Fiber cement siding (R703.10)
Vinyl siding (R703.11)
ROOF -CEILING CONSTRUCTION (Chapter 8)
GENERA (R801)
Design (R801.2 and R801.3)
Component and cladding wind loads [Table
R301.2(2)]
ROOF FRAMING (R802)
Fire -retardant -treated wood (R802.1.3)
%v Framing details (R802.3)
N Rafter tie (R802.3.1)
W�h Collar ties (4' o.c., in upper third of attic)
(R802.3.1)
N�
Purlins (2" x 4" at 4' o.c. minimum)
(Figure R802.5.1, R802.5.1)
Bearing (R802.6)
Cutting and notching (R802.7)
Engineered wood products (R802.7.2)
Lateral support and bridging (R802.8)
/ �'�raming of openings (R802.9)
_Good trusses (R802.10)
Roof tie -down (R802.11)
CEILING JOISTS [Tables R802.4(1), R802.4(2)]
IV Ifs
Without attic storage, LL = 10psf
1"",14
With attic storage LL = 20psf
Spacing
Species
Grade
Span
Size
RAFTERS [Tables R802.5.1(1) - R802.5.1(8)]
Ground snow load/LL = 20psf
Controlling design (LL or snow)
Ceiling not attached/ceiling attached
Spacing
Species
Grade
Span
Size
Hc/HR; Adjustment factor
ROOF SHEATHING (R803.2)
l/ 1 Grade
(/ Thickness
FRTW allowable stresses/grading
Allowable spans [Table R503.2.1.1(1)]
Installation (R803.2.3)
ISM
ROOF -CEILING CONSTRUCTION (cont'd.)
STEEL ROOF FRAMING (R804)
General (R804.1)
Structural framing (R804.2)
Material (R804.2.1)
Identification (R804.2.2)
Corrosion protection (R804.2.3) l-7
Fastening (R804.2.4)
Roof construction (R804.3)
Roof tie -down (R804.3.9)
ROOF V%NTILATION (R806)
!% Ventilation requirements (R806.1 - R806.4)
ATTIC ACCESS (R807)
Access requirements (807.1)
ROOF ASSEMBLIES (Chapter 9)
ROOVF6ASSIFICATION (R902)
Roof covering materials (R902.1)
WEATHER PROTECTION (R903)
//,-:2 "'o
Flashing (R903.2)
1A
Coping (R903.3)
Roof drainage (R903.4)
P" t1a
Hail exposure (R903.5)
MATERIA (R904)
Compatibility; specifications; physical
characteristics; identification (R904.2 -
R904.4)
REQUIREMENTS FOR ROOF COVERINGS (R905)
Asphalt shingles (R905.2)
N/x
Clay and concrete tile (R905.3)
IV,ld
Metal roof shingles (R905.4)
Mineral -surfaced roll roofing (R905.5)
�r Slate and slate -type shingles (R905.6)
Wood shingles (R905.7)
/V Wood shakes (R905.8)
IV�W Built-up roofs (R905.9)
Metal roof panels (R905.10)
lea,
bitumen roofing (R905.11)
�/ � Thermoset single -ply roofing (R905.12)
Thermoplastic single -ply roofing (R905.13)
Sprayed polyurethane foam roofing (R905.14)
/y t¢ Liquid -applied coatings (R905.15)
ROOF INSULATION (R906)
i'" /� General (R906.1)
REROOFING (R907)
Materials and methods (R907.1)
Structural support (R907.2)
Recover vs replace (R907.3)
CHIMNEYS AND FIREPLACES (Chapter 10)
MASONRY FIREPLACES (R1001)
Construction (Figure R1001.1 and Table
R1001.1)
SDC D reinforcing/anchorage (R1001.3 and
VVR 1001.4)
Firebox walls and dimensions (R1001.5 and
IrT
R1001.6)
Steel fireplace units (R1001.5.1)
Lintel (noncombustible) (R1001.7)
Hearth extension material (R1001.9)
Hearth extension (R1001.10)
Fireplace clearance (R1001.11)
Fireblocking (R1001.12)
MASONRY CHIMNEYS (R1003)
Construction (Table R1001.1, R1003.2,
R1003.3, and Figure R1001.1)
Corbeling (R1003.5)
CHIMNEYS AND FIREPLACES (cont'd.)
Changes in dimension (R1003.6) Chimney clearance (R1003.10)
Additional load (R1003.8) Fireblocking (R1003.19)
Termination (R1003.9) P74'Chimney crickets (R1003.20)
Spark arrestors (R1003.9.1)
Wall thickness; >_ 4" (R1003.10)
Flue lining - material/installation (R1003.11
and R1003.12)
Multiple flues (R1003.13)
Flue area (appliance) (R1003.14)
Flue area (masonry fireplace) (R1003.15)
Inlet (R1003.16)
Cleanout opening (R1003.17)
FACTORY -BUILT FIREPLACES (R1004)
Listed and labeled (R1004.1)
Installation (R1004.2)
FACTORY -BUILT CHIMNEYS (R1005)
71 Listed and labeled (R1005.1)
(/ Installation (R1005.3 and R1005.4)
EXTERIOR AIR SUPPLY (R1006)
Intake size (R1006.2, R1006.4)
ENERGY EFFICIENCY* (Chapter 11)
Com liance• material and equipment v uilding envelope (N1102)
p q P
(N1101.2, N1101.3)
Mechanical systems (N1103)
Climate zone (Table N1101.2)
`See energy conservation plan review record
MECHANICAL (Chapters 12-23)
Appliance labeling (M1302, M1303)
/ 0" 0 P Appliance access (M1305, M1401)
=1�� Appliance installation (M1307)
C/ Heating and cooling equipment; heating
and cooling load calculations (Chapter 14)
or
xhaust systems (Chapter 15)
Duct systems (Chapter 16)
P",M Combustion air (Chapter 17)
Application (G2401.1)
" General regulations (G2404)
v Appliance location (G2406)
Air requirements (G2407)
P"I f Installation (G2408)
Chimney and vent location and terminations
(Chapter 10 and Chapter 18)
%yV
Special fuel -burning equipment (Chapter 19)
Boilers/water heaters (Chapter 20)
N f04
Hydronic piping (Chapter 21)
N .B
Special piping and storage systems
(Chapter 22)
Solar systems (Chapter 23)
14"11,4
Penetrations of fire -resistance rated assem-
blies (R302.4, R302.5)
FUEL GAS (Chapter 24)
/ys-/ Clearances (G2409)
/a S to Electrical and electrical bonding (G2410,
G2411)
Pipe sizing (G2413) 7
Piping materials (G2414)
-10-
FUEL GAS (cont'd)
/,A-$/ Piping installation (G2415 and G2419) /""J 0 Venting (G2426 - G2429)
Piping support (G2418 and G2424) NMisc appliances (G2423, G2425, G2430 -
Valves, controls, connections (G2420, G2421 G2453)
. and G2422)
PLUMBING (Chapters 25-33)
ia'St" Water service location and depth (P2603,
P2604)
Sanitary and storm sewer location and depth
(P2603, P2604)
Piping support (Table P2605.1)
/'1' 1'/ Listed plastic materials (P2608)
Plumbing, fixtures (Chapter 27)
Water heater size and location (Chapter 28)
A11A_ Water supply and distribution system design
and calculations (Chapter 29)
A//A Dwelling unit fire sprinkler systems (P2904)
NFPA 13D system (P2904.1)
Temperature rating
(P2904.2.1, P2904.2.2)
Freezing protection
(P2904.2.3)
Sprinkler coverage
(P2904.2.4)
Piping materials (P2904.3)
Flow rates (P2904.4.1,
P2904.4.2)
Water supply capacity
(P2904.5.2)
Pipe sizing (P2904.6)
Drain, waste and vent pipe sizing and rise
diagram (P3004, P3005, Chapter 31) " �/JJ
ti/A Sumps and ejectors (P3007)
/_, Backwater valves (P3008)
Al (A Fixture traps (P3201)
Storm drainage (Chapter 33)
Penetrations of fire -resistance rated assem-
blies (R302.4, R302.5)
ELECTRICAL (Chapters 34-43)
IWJ9
Penetrations of fire -resistance rated assem-
blies (E3402.2)
P
Listed and labeled materials (E3403)
Service equipment and location (E3405,
/
E3601, E3606)
v
Service size and load calculations (E3602)
Available fault current (E3606)
System grounding (E3607)
Required branch circuits (E3703)
f/
Feeder requirements and load calculations
(E3704)
Wiring methods (Chapter 38)
Required lighting and recepta
cle outlets
/
(E3901, E3903)
v
Ground -fault and arc -fault circuit -interrupter
protection (E3902)
^'J r
Devices and lighting fixtures (Chapter 40)
IA-rl.
Appliance installation (Chapter41)
/" /Q
Swimming pools (Chapter 42)
IV1A
Class 2 remote -control, signaling and power -lim-
ited circuits (Chapter 43)
MANUFACTURED HOUSING USED AS DWELLINGS (Appendix E)
l ovisions adopted (R102.5)
^ 0 Compliance with Appendix E verified
J
RADON CONTROL MEASURES (Appendix F)
Provisions adopted (R102.5) Compliance with Appendix F verified
SWIMMING POOLS, SPAS AND HOT TUBS (Appendix G)
Provisions adopted (R102.5) Compliance with Appendix G verified
PATIO COVERS (Appendix H)
Provisions adopted (R102.5) Compliance with Appendix H verified
PRIVJATE SEWAGE DISPOSAJZ/(Appgrndix 1)
Provisions adopted (Rr2.5)/ \ 7 Compliance vyjth Appendix I verified
EXISTihl BUILDINGS AND JTRUCTU
Provisions adopted 102.5)
SOUND TRANSMISSION (Ap
K)
dix J)
with Appendix J verified
Provisions adopted (R102.5) Compliance with Appendix K verified
HOME DAY CARE—R-3 OCCUPANCY (Appendix M)
Provisions adopted (R102.5) Compliance with Appendix M verified
-12-
1'1
NOTICE OF COMMENCEMENT
i 13p�-tzS4
��ermit No
State of Florida
.County of St. Lucie
Tax Folio
The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes,
thefollowing information is provided in this Notice of Commencement.
N'
Legal Descotion of
_L'o / 7.7
(and street address if available):
Svhdl u•,S. iA
y
-
General description'of improvement: ---
Owner information or Lessee m orm tion if the Lessee contracted for the improvement:
Name GP �,s, S / o/� e.✓n
Address y? 7l0 /dun/!. ka j5L. i ,`eiGe V 9E/
ert Interest in ro : 4/i'1 e/ - - -.
P P Y -- � - - . _ � O ,i cn c-
Name and address of fee simple titleholder (if different from Owner listed above): rn ;Q m O
0M*kZrn
- - - - -.
--- — ----. --- - r7wr-.i
;-ontractor's Name: ✓/le-
i ti m
� „Nmui
Contractor Address: one Number: 0
Suretyif applicable, a co of the payment bond is attached): of bond: $ rn ^} .
( Pp PY p Y ) n
Name and address: Phone number: "w m
� m �
I W �
G1 to
!_ender Name: Phone Number: o o -n
Lender's address: pro
m
Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by SE
713.13(1)(a)7., Florida Statyytes: z c
Name: t? Uo /7v R" Lam,, Phone Number: %7a- -?16 1/2 % 6/ -4
Address: n / / f 1? B/e-e ice/ 3 p
c
In addition to himself or herself, Owner designates of to receive a cope
Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes.
Phone number of person or entity designated by owner: — -
Expiration date of notice of commencement: (the expiration date may not be before the completion of construction and final payment to the
-ontractor, but will be 1 year from the date of recording unless a different date is specified)
l
''WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED
IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR
RECORDING YOUR NOTICE OF COMMENCEMENT.
U nder penalty of perjury, l declare that I have read the foregoing notice of commencement and that the facts stated therein are true to the best of
my knowle gynd belief. /
(Sign ture of Owner or Lesse wner's or Lessee's Authorized Officer/Director/Partner/Manager
(Signatory's Title/ Office) ov
CATHERINE A. WEINMAN
NOTAW(PUBLIC
The foregoing instrument was acknowledged before me thisday otVVM& 201-�aTATE OF FLORIDA
CommOEE095576
y as t/2for Ex Pireis 8/23/2n14
me of Person Type of authority (e.g.office r,trustee) Party on behalf of whom instrument was executied
Personally known_or produced Identification.
gnature of otar lic - State of Florida)
(Print, Type, or tamp Commissioned Name of Notary Public) Type of Identification produced
Lydia Galbraith
From: Mike Halter
Sent: Tuesday, January 22, 2013 12:33 PM
To: Lydia Galbraith
Subject: RE: 4776 Dunn Rd Fort Pierce, 3403-502-0139-000/0
No stormwater permit.
Thanks
Michael
2719
From: Lydia Galbraith
Sent: Tuesday, January 22, 2013 11:16 AM
To: Mike Halter
Subject: 4776 Dunn Rd Fort Pierce, 3403-502-0139-000/0
Hi Mike,
We have a permit in for a Guest house with asphalt milling driveway. Paula asked me to check with you if you would
need to check this on drainage? The property is about 9.5 acres. See attached copy of the survey.
Thanks,
L_UOU0 g caLbratth
Planning Technician
Planning and Development Services
Phone: (772) 462-1555
Fax: (772) 462-6448
Email: Qalbraithlastlucieco.org
Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records
available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and !
or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error,
please notify the sender by reply e-mail and delete all materials from all computers.
Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records
available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and /
or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error,
please notify the sender by reply e-mail and delete all materials from all computers.
r -\
Planning & Development Services
Building &Code Regulation Division
Permitting Department
2300 Virginia Avenue
Fort Pierce, FL 34982
Phone: (772) 462-1553 Fax: (772) 462-1578
To Be Review by Plans Exan Pending
Zoning Review Incomplete
�
Review Comments I
(301 - 0 n 5q
Lydia Galbraith 01/10/2013
2
01/10/2013 1
Comment PLEASE PROVIDE SUB AGREEMENTS FOR ELECTRICAL, PLUMBING, MECHANICALAND ROOF.
01/10/2013 3
Comment PLEASE SIGN AND SUBMIT THE GUEST HOUSE AFFIDAVIT
01/10/2013 4
Comment SURVEY:
AT 2/16/2012 FEMA HAS ISSUED NEW FLOOD ZONE MAPS. PERMITS WITH SURVEYS SUBMITTED
AFTER THIS DATEARE REQUIRED TO REFLECT THE UP AT ED DATA.
PLEASE INDICATE THE PROPOSED FINISHED FLOOR ELIOL`1O., . SURVEY.
THE DIMENSIONS OF THE HOUSE ON THE SURVEY ARE N ATCI BUILDING
PLANS. �� ,
THE PORCH IS PART OF THE HOUSE AND SHOULD BE INDICATEDAS� LINES.
PLEASE INDICATE THE TYPE OF SURFACE FOR THE PROPOSED DRIVEWAY ON THE SURVEY.
PLEASE PROVIDE 2 SIGNED AND SEALED CORRECTED SURVEYS. THE SURVEY DOESN'T HAVE
TO BE RE -STAMPED BY THE HEALTH DER
01/14/2013 5
Comment PLEASE SUBMIT AN APPLICATION FOR THE DRIVEWAY FOR OUR ROAD & BRIDGE DEPARTMENT.
01/14/2013 6
Comment PLEASE BE AWARE THAT ABOVE COMMENTS ONLY REFLECT THE ZONING REVIEW. THE PLANS
EXAMINER MIGHT HAVE ADDITIONALC COMMENTS.
01/14/2013 7
Comment 1/14/13 E-MAIL TO OWNER WITH COMMENTS.
Planning & Development Services
Building & Code Regulation Division
Permitting Department
2300 Virginia Avenue
Fort Pierce, FL 34982
Phone: (772) 462-1553 Fax: (772) 4624578
PROPERTY INFORMATION
Address: 4776 DUNN RD
City / State I Zip: FORT PIERCE
Parcel # : 3403-502-0139-000/0
Zoning: AR-1
APPLICATION INFORMATION
Permit Number: 1301-0054
Activity Type: New
Permit Type: BRG (Guest House)(214)
CONTRACTOR INFORMATION
Contractor Name:
Business Name:
Business Addr.
City / State I ZIE
Review Comments
FL 34981
Jurisdiction: St. Lucie County
Lot # : 77 Block:
Owner(s):
Lewis Holloway
Starlyn Holloway
Page 1
Application Type: Building Permit w/o subs
Other Activity:
Stories: 1 Automatic Sprinkler System?
Fax Number - -
REVIEWS AND COMMENTS
Review Type Status Reviewed By Date Started Date Complete Date Released
Documents Missing Pending Deanna Gvens
01/07/2013 1 Comment RECORDED NOTICE OF COMMENCEMENT
01/07/2013 2 Comment 1/17/13 VEG PERMIT IN DRAWER UNDER "H" FEES ARE LOADED
VEG PERMIT SENT TO ERD ON 01/07/13
01/10/2013 3 Comment SIGNTURE ON ENERGY CALCS AND DISPLAY CARD MISSING.
Front Counter Review Complete Deanna Gvens 12/31/2012 01/07/2013
To Be Reviewed by Zoning Complete 01110/2013
(Company/Individual Name)
project located at
PLANNING & DEVELOPMENT SERVICES DIVISION
BUILDING & CODE REGULATIONS DIVISION
2300 Virginia Ave
Fort Pierce, FL 34982
BUILDING PERMIT
SUB -CONTRACTOR SUMMARY RECEIVED
will be using the following �� suhtrors for the
J 2013
(Street address or Property Tax ID #)
It is understood that if there is any change of status regarding the participation of any of the sub -contractors
listed below, I will immediately advise the Building and Zoning Department of St. Lucie County.
Trade
Name of Company/Contractor
St. Lucie County/
State of Florida
License Number
Electrical
r r
l az
Plumbing
�1,,� 6
HVAC/
OUTA6 1� irU Db-l�
Mechanical
Roofing
Gas
nFFT!'F TTCF. f1NT.V-
PERMTT ISSUE DATE:
NUMBER: _ r
PLANNING & DEVELOPMENT SERVICES DEPARTMENT
BUILDING & CODE REGULATIONS DIVISION
BUILDING PERMIT
SUB -CONTRACTOR AGREEMENT
St. Lucie County Contractor Certification Number:
State of Florida Certification Number (If applicable):
have agreed to be the
(Company Name/Indi
sub -contractor for Ocln ci,' (type of of Trade) ` (Primary Contractor)
for the project located at 1/77 6 /�ri.,n �� %'1��" /. 3 �/9.8
(Project Street Address or Property Tax ID #)
It is understood that, if there is any change of status regarding our participation with the
above mentioned project, I will immediately advise the Building and Zoning Department
of St. Lucie County by personally filing a Change of Contractor notice. (Form: SLCCDV
No. 004-00)
BUSINESS QUALIFIER (Name of the Individual shown on the Contractor's License)
ORIGINAL SIGNATURES ARE REQUIRED
S GCE PRINT NAME DATE
Business Name:
Address:
City/State/Zip:
Phone:
OFFICE USE ONLY:
email:
PERMIT # ISSUE DATE
PLANNING & DEVELOPMENT SERVICES DEPARTMENT
BUILDING & CODE REGULATIONS DIVISION
BUILDING PERMIT
SUB -CONTRACTOR AGREEMENT
St. Lucie County Contractor Certification Number:
State of Florida Certification Number (If applicable):
(Company Name/Indi
UM sy7v(3
(Type of Trade)
have agreed to be the
Name)
sub -contractor for / 13vylcltl-
(Primary Contractor)
for the project located at 4/ 7 7 6 DdAn iU Z/ -TY 9 R-7
(Project Street Address or Property Tax ID #)
It is understood that, if there is any change of status regarding our participation with the
above mentioned project, I will immediately advise the Building and Zoning Department
of St. Lucie County by personally filing a Change of Contractor notice. (Form: SLCCDV
No. 004-00)
BUSINESS QUALIFIER (Name of the Individual shown on the Contractor's License)
ORIGINAL SIG ATURES ARE REQUIRED
SfGNATUFK PRINT N`XME DATE
Business Name:
Address:
City/State/Zip:
Phone: email:
OFFICE USE ONLY:
PERMIT # ISSUE DATE
PLANNING & DEVELOPMENT SERVICES DEPARTMENT
BUILDING & CODE REGULATIONS DIVISION
BUILDING PERMIT
SUB -CONTRACTOR AGREEMENT
St. Lucie County Contractor Certification Number:
State of Florida Certification Number (Ifapplicable):
have agreed to be the
(Company Name/Individu Name)
/ V I bE,&q1?,&C 11` sub -contractor for el- 1_3v,, 1-'e
(Type of Trade) (Primary Contractor)
for the project located at 4/776 1q,, RU / Y /2'Cice `/. ZV_9kk
(Project Street Address or Property Tax ID #)
It is understood that, if there is any change of status regarding our participation with the
above mentioned project, I will immediately advise the Building and Zoning Department
of St. Lucie County by personally filing a Change of Contractor notice. (Form: SLCCDV
No. 004-00)
BUSINESS QUALIFIER (Name of the Individual shown on the Contractor's License)
ORIGINAL SIGNATURES ARE REQUIRED
.rl
L ,s / ,��
S NAT PRINT NAN E DATE
Business Name:
Address:
City/State/Zip:
Phone:
OFFIC"F ITSF, ONLY:
email:
PERMIT # ISSUE DATE
1 J ,
PLANNING & DEVELOPMENT SERVICES DEPARTMENT
BUILDING & CODE REGULATIONS DIVISION
BUILDING PERMIT
SUB -CONTRACTOR AGREEMENT
St. Lucie County Contractor Certification Number:
State of Florida Certification Number (If applicable):
have agreed to be the
(Company Name/Individual Name)
Zoo/_� sub -contractor for
(Type of Trade) (Primary Contractor)
for the project located at
L/ 77 G ,c?v✓+yt >2oC 19- P `tic e `/. 3 "'ff/
(Project Street Address or Property Tax ID #)
It is understood that, if there is any change of status regarding our participation with the
above mentioned project, I will immediately advise the Building and Zoning Department
of St. Lucie County by personally filing a Change of Contractor notice. (Form: SLCCDV
No. 004-00)
BUSINESS QUALIFIER (Name of the Individual shown on the Contractor's License)
ORIGINAL SIGNATURES ARE .REQUIRED
JK SIGNAT PRINT NAME DATE
Business Name:
Address:
City/State/Zip:
Phone: email:
( 1P1PI` 'F. TTCF. ONT,V!
v PERMIT # v ISSUE DATE
r'c'691CiNTY O R [ D'
PLANNING AND DEVELOPMENT SERVICES DEPARTMENT
Building and Code Regulations Division
2300 VIRGINIA AVE
FORT PIERCE, FL 34982
772-462-1553
GUEST HOUSE AFFIDAVIT
RECEIVEL)
JAN 1 2013
I hereby affirm that Building Permit # r G 0 5
is to be issued for a guest house which will not be used for rental purposes, seasonally
or annually, under any circumstances.
Print Owner's Name Si nature OL>
STATE OF FLORI`Y�A���
COUNTY OF
The fo a oing,instru en as acknowledged before me this day o , 20/3
by S personally known to me Xj or who has prodpLed
as identification.
7 04�
Si natu e o ota
Commission Number ARNq Nota�N hWhINE A WEINMAN
NOTARY PUBLIC
STATE OF FLORIDA
. Comm# EE015676
EXPIrbs 8/23/2014
SLCPDSD Revised 08/24/2010 .
I ! �
Lydia Galbraith
From:
Lydia Galbraith
Sent:
Monday, January 14, 2013 3:44 PM
To:
'starlynholloway@yahoo.com'
Subject:
Permit 1301-0054, guest house
Attachments:
DOC 1301-0054-1.pdf, Guest House Affidavit 2011.docx; DW_Permit_Appl_revised.pdf
Mr. Holloway,
Attached the Zoning review comments.
If you have any questions, please let us know.
Thanks,
L-Ud'a g cIaLbraLth
Planning Technician
Planning and Development Services
Phone: (772) 462-1555
Fax: '(772) 462-6448
Email: galbraithl(LDstlucieco.org
Planning & Development Services
Building 8, Code Regulation Division
Permitting Department
2300 Virginia Avenue
Fort Pierce, FL 34982
Phone: (772) 462-1653 Fax: (772) 462-1578
PROPERTY INFORMATION
Address:
4776 DUNN RD
City / State / Zip;
FORT PIERCE
Parcel # :
3403-502-0139-000/0
Zoning:
AR-1
APPLICATION INFORMATION
Permit Number: 1301-0054
Activity Type: New
Permit Type: BRG (Guest House)(214)
CONTRACTOR INFORMATION
Contractor Name:
Business Name:
Business Addr:
City / State / Zil
REVIEWS AND COMMENTS
Review Comments
FL 34981
Jurisdiction: St. Lucie County
Lot # : 77 Block:
Page 1
Owner(s):
Lewis Holloway
Starlyn Holloway
Application Type: Building Permit w/o subs
Other Activity:
Stories: 1 Automatic Sprinkler System?
Fax Number - -
Review Type Status Reviewed By Date Started Date Complete Date Released
Documents Missing Pending Deanna Gvens
01/07/2013 1 Comment RECORDED NOTICE OF COMMENCEMENT
01/07/2013 2 Comment VEG PERMIT SENT TO ERD ON 01/07/13
01/10/2013 3 Comment SIGNTURE ON ENERGY CALCS AND DISPLAY CARD MISSING.
Front Counter Review Complete
Deanna Gvens
12/31/2012 01/07/2013
To Be Reviewed by Zoning Complete 01/10/2013
1
Planning & Development Services
Building & Code Regulation Division
Permitting Department
2300 Virginia Avenue
Fort Pierce, FL 34982
Phone: (772) 462-1553 Fax: (772) 462-1578
To Be Review by Plans Exar Pending
Zoning Review Incomplete
Review Comments
Lydia Galbraith 01110/2013
Page 2
01/10/2013 1 Comment PLEASE PROVIDE SUB AGREEMENTS FOR ELECTRICAL, PLUMBING, MECHANICALAND ROOF.
01/10/2013 2 Comment THE SUB AGREEMENT FOR GAS IS NOT SIGNED BY THE QUALIFIER OF THE COMPANY. ONLY
THE QUALIFIER TIM RUSSELL IS ALLOWED TO SIGN SUB AGREEMENTS.
PLEASE PROVIDE A SUB AGREEMENT SIGNED BY THE CORRECT PERSON.
01/10/2013 3 Comment PLEASE SIGN AND SUBMIT THE GUEST HOUSE AFFIDAVIT
01/10/2013 4 Comment SURVEY:
AT 2/16/2012 FEMA HAS ISSUED NEW FLOOD ZONE MAPS. PERMITS WITH SURVEYS
SUBMITTED AFTER THIS DATE ARE REQUIRED TO REFLECT THE UPDATED DATA.
PLEASE INDICATE THE PROPOSED FINISHED FLOOR ELEVATION ON THE SURVEY.
THE DIMENSIONS OF THE HOUSE ON THE SURVEYARE NOT MATCHING WITH THE BUILDING
PLANS.
THE PORCH IS PART OF THE HOUSE AND SHOULD BE INDICATED AS SOLID LINES.
PLEASE INDICATE THE TYPE OF SURFACE FOR THE PROPOSED DRIVEWAY ON THE SURVEY.
PLEASE PROVIDE 2 SIGNED AND SEALED CORRECTED SURVEYS. THE SURVEY DOESN'T HAVE
TO BE RE -STAMPED BY THE HEALTH DER
01/14/2013 5 Comment PLEASE SUBMITAN APPLICATION FOR THE DRIVEWAY FOR OUR ROAD & BRIDGE
DEPARTMENT.
01/14/2013 6 Comment PLEASE BE AWARE THATABOVE COMMENTS ONLY REFLECT THE ZONING REVIEW. THE
PLANS EXAMINER MIGHT HAVE ADDITIONALC COMMENTS.
Lydia Galbraith
From:
James D. Beams, Sr.
Sent:
Monday, January 14, 2013 2:41 PM
To:
Lydia Galbraith
Subject:
RE: 4776 Dunn Rd
Yes they will need a permit for a new connection. $150.00
From: Lydia Galbraith
Sent: Monday, January 14, 2013 1:58 PM
To: James D. Beams, Sr.
Subject: FW: 4776 Dunn Rd
Hi Jimmy,
Did you have a chance to look at this one?
Thanks,
t_i�d�a g Ca�bra�tl�
Planning Technician
Planning and Development Services
Phone: (772) 462-1555
Fax: (772) 462-6448
Email: aalbraithl .stlucieco.org
From: Lydia Galbraith
Sent: Thursday, January 10, 2013 11:35 AM
To: James D. Beams, Sr.
Subject: 4776 Dunn Rd
Hi Jimmy,
We have a permit in for a guesthouse with new driveway (see attached copy of survey) Do they need a.driveway permit
and if so I assume it will be $150.00?
Please let me know.
Thanks,
L_l OILa g ctaLbraLth
Planning Technician
Planning and Development Services
Phone: (772) 462-1555
Fax: (772) 462-6448
Email: galbraithl(cDstlucieco.org
1
Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records
available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and /
or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error,
please notify the sender by reply e-mail and delete all materials from all computers.
Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records
available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and
or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error,
please notify the sender by reply e-mail and delete all materials from all computers.
PLANNING & DEVELOPMENT SERVICES DIVISION
BUILDING & CODE REGULATIONS DIVISION
2300 Virginia Ave
Fort Pierce, FL 34982
BUILDING PERMIT
SUB -CONTRACTOR SUMMARY
L ,S 410 �,✓d. will be using the following sub -contractors for the
(Company/Individual Nam
project located at —3 yU ' �U a ^ a 3
(Street address or Property Tax ID #)
It is understood that if there is any change of status regarding the participation of any of the sub -contractors
listed below, I will immediately advise the Building and Zoning Department of St. Lucie County.
Trade
Name of Company/Contractor
St. Lucie County/
State of Florida
License Number
Electrical
69 (//l e / i3 u • 1ke i
Plumbing
-13 a - 'Id
HVAC/
�.✓h /3v'�d�/
Mechanical
Roofing
Gas
DFFICE USE ONLY:
PERMIT ISSUE DATE:
NUMBER: �Q�' CO��"I
PLANNING & DEVELOPMENT SERVICES DEPARTMENT
I BUILDING & CODE REGULATIONS DIVISION
BUILDING PERMIT
SUB -CONTRACTOR AGREEMENT
z �� p ��
St. Lucie County Contractor Certification Number:
State of Florida Certification Number (if applicable): 03 7
have agreed to be the
(Compa6y Name/Individual Name)
L��&sub -contractor for
(Type of Trade) (Primary Contractor)
for the project located at77�p
(Project Street Address or Property Tax ID #)
It is understood that, if there is any change of status regarding our participation with the
above mentioned project, I will immediately advise the Building and Zoning Department
of St. Lucie County by personally filing a Change of Contractor notice.. (Form: SLCCDV
No. 004-00)
BUSINE SS QUALIFIER (Name of the Individual shown on the Contractor's License)
RR.1(;INN A I... SK;NA11. RES A11E EQ1i.. 11E1)
-'A
lc
8—/Z
SIG ATURE PRINT NAME DATE ;
Business Name:
Address:
City/State/Zip:
Phone:
OFFICE USE ONLY:
email:
PERMIT # ISSUE DATE
�/-
DEBRA J. NAYLOR
MY COMMISSION #DD988453
EXPIRES: JUL 30, 2014
»•• Bonded through 1st State Insurance
Planning & Development Services Department
Building & Code Regulations Division
2300 Virginia Ave
Fort Pierce, FL 34982
772-462-1553
Owner Builder Affidavit — Electrical Contracting
DISCLOSURE STATEMENT
F.S. 489.503 (6) EXEMPTIONS
State law requires electrical contracting to be done by licensed electrical contractors. You have applied for a
permit under an exemption to that law. The exemption allows you, as the owner of your property, to act as your own
electrical contractor even though you do not have a license. You may install electrical wiring for a farm outbuilding
or a single-family or duplex residence. You may install electrical wiring in a commercial building the aggregate
construction costs of which are under $75,000. The home or building must be for your own use and occupancy. It
may not be built for sale or lease. If you sell or lease more than one building you have wired yourself within 1 year
after the construction is complete, the law will presume that you built it for sale or lease, which is a violation of this
exemption. You may not hire an unlicensed person as your electrical contractor. Your construction shall be done
according to building codes and zoning regulations. It is your responsibility to make sure that people employed by
you have licenses required by state law and by county or municipal licensing ordinances. Failure to do so may result
in a liability for you!
To qualify for this exemption under this subsection, an owner must personally appear and sign the building
permit application.
I hereby acknowledge that I have read and understand the above disclosure statement and that I
further understand that any violation of the terms of the owner/builder exemption shall be reported by the
Community Development Director to the Florida State Department of Professional Regulation. Signed and
acknowledged on this _ 2 day of T&" , 20 / >
Iff
OWNER/BUILDERMOR
STATE OF FLORIDA
COUNTY OF Sk.1, OCA t
The foregoing instrument was acknowledged before me this 1 day of Ick ft_ , 20 Aj ,
by L%w k S iA o l% o w o.4 , who is personally known to me or
has produc F L 'A L6b -5a1 �G6 — Na.S a as identification.
M> � �:dYVfha1, &\ V%.^S (Seal)
Signature of Notary Print name of Notary
Title: Notary Public Commission Number
SLCPDSD Revised 7/23/2010
St. Lucie County Owner Builder Affidavit -Electrical Contracting
�
I
Planning & Development Services Department
Building & Code Regulations
2300 Virginia Avenue
Fort Pierce, Florida 34982
(772)462-1553
OWNER/BUILDER AFFIDAVIT DISCLOSURE STATEMENT
F.S. 489.103 (7) EXEMPTIONS
State law requires construction to be done by licensed contractors. You have applied for a permit under an
exemption to that law. The exemption allows you, as the owner of your property, to act as your own contractor even
though you do not have a license. You must provide direct, on -site supervision of the construction yourself. You
may build or improve farm outbuildings, a one -family or two-family residence or a commercial building at a cost of
under $75,000.00. The building or residence must be for your own occupancy. It may not be built or substantially
improved for sale or lease. If you sell or lease a building you have built or substantially improved your self within
one year after the construction is complete, the law will presume that you built or substantially improved it for sale
or lease, which is a violation of this exemption. You may not hire an unlicensed person to act as your contractor or
to supervise people working on your building; it is your responsibility to make sure that people employed by you
have licenses required by state law and by county or municipal licensing ordinances. You may not delegate the
responsibility for supervising work to a licensed contractor who is not licensed to perform the work being done.
Any person working on your building who is not licensed must work under your direct supervision and must be
employed by you, which means that you must deduct F.I.C.A. and withholding tax and provide workers'
compensation for that employee, all as prescribed by law. Your construction must comply with all appliablg�aws,
tial P,
ordinances, building codes, and zoning regulations. Ini
I understand that the building official and inspectors are not there to design or give advice on how to )neet
the minimum code. Initial Ly/ 11-
I understand that as an owner -builder that any contract disputes with sub -contractors and I must be handled
in a civil court with the advice of an attorney. This department will not mitigate any contract disputes. �{
Initial
I understand that if I compensate any person or company for work performed they are required to be
licensed in this jurisdiction. If for some reason they do not possess a license, I may be responsible and liable fq>; the
cost of the license. Initial LW
I understand that if any person that is unlicensed and uninsured gets injured on my construction project -
they may be entitled to workmen's compensation. I could be held liable for all doctor, lawyer and relate ical
cost, which could include loss of wages during recovery from their injury. Initial
To qualify for this exemption under this subsection, an owner must personally appear and sign the building
permit application and initial the above.
I hereby acknowledge that I have read and understand the above disclosure statement and that I further
understand that any violation of the terms of the owner/builder exemption shall be reported by the Building and
Zoning Department to the Florida Stat Department of Professional Regulation. Signed and acknowledged on this
7 day of J`g n. of20.
Owner/Builder Si afire
STATE OF FLORIDA
COUNTY OF Sk, L o c t
The foregoing instrument was acknowledged before me this Tkb day of '3a.v , 20 0 ,
by L.-,vz15 \N a %\ d uJ " who is personally known to me, who s
producedO L A4 as identification.
Signature of No ary Type or Print Name of Notary (Seal)
Title: Notary Public Commission Number CE 4 G(I4; J _ ��`��•�
SLCPDSD Revised 07/22/2010 ,� pv Pu''., DEAD stow T
,•,0,11".
, Notary Public stow FI
_ My Comm. E><D
Gommlysl'on +► Er
?
Bonded 1Mou� Nate'
� I
i
PLANNING & DEVELOPMENT SERVICES DEPARTMENT
BUILDING & CODE REGULATIONS DIVISION
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982-5652
(772) 462-1553
FILLED LANDS AFFIDAVIT
I, the undersigned, am the owner of the following described property,
3 y0 3.5o z"0 aoo -C2
y;>'76 ,2 ✓ )5�L, /%G 3 ytie/
(Parcel Id#/Legal description/Address)"
for which I have applied to St. Lucie County for a Final Development Permit. In
accepting this Final Development Permit, BP Number , I acknowledge
that as owner of the above described property, and in accordance with Section
7.04.01(D), St. Lucie County Land Development Code, I shall be responsible for assuring
adequate drainage so that the immediate community WILL NOT be adversely affected.
I further acknowledge that in granting this permit for the development of this property,
St. Lucie County is neither obliged nor liable to provide for, or maintain in any form,
adequate drainage off my property which will not adversely affect the immediate
community.
G 142 Awa,
Property Owner Name (Pleaek Print)
Property O e
STATE OF FLORIDA, COUNTY OF
/-7- /3
Date
ACKNOWLEDGED BEFORE ME THIS 1 �-b DAY OF q 20 I3
BY �-! w� S �IC G \\C W WHO IS PERSONALLY KNOWN TO ME OR O HAS
PRODUCED F L O L H L%00 - S-2. 1 Coe J a S- 4 AS IDENTIFICATION.
' ..J-D'tan+►aGiy.
SIGNATURE OF ROTARY PUBLIC TYPE OR PRINT NOTARY
VCOMMISSION NUMBER
(SEAL)
aim
��••�p�1A WNS
f P
Notary pusllc .; SWO of Florida
,r r • e My Comm. ExpNa Oac �8� Z016:
'sN. oe: Commiyei'on 0 EE i1 el
Bonded lhlougb NMio1a1
SLCPDSD Revised 08/24/2010
KSM
KELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, INC.
MARTIN (772) 337-7755 P0. BOX 78-1377, SEBASTIAN, FL 32978-1377 SEBASTIAN (772) 589-0712
PALM BEACH (561) 845-7445 www.ksmengineering.net MELBOURNE (321) 768-8488
FAX (561) 845-8876 E-Mail: KSMQKSMENGINEERING.NET ST. LUCIE (772) 229-9093
C.A.: 5693 FAX (772) 589-6469
DATE TESTED
PERMIT #
CONTRACTOR
JOB LOCATION
SOIL COMPACTION REPORT
ASTM D 1557 and ASTM D 2922
February 19, 2013
1301-0054
Lewis Holloway
4776 Dunn Road
Fort Pierce, Florida
ITEM TESTED Compacted Foundation Fill for Guest House
KSM JOB # : 130280-1 d/ES/km
TEST LOCATION
* PEN
DRY
MAX. DRY
PERCENT
OF SAMPLE
DEPTH
READ
DENSITY
PROCTOR VALUE
COMPACTION
1.
N. E.
0" - 12" 40
112.1
114.1
98.2
2.
N.W.
48
113.4
99.4
3.
S. E.
52
111.9
98.1
4.
S.W.
48
112.4
98.5
Soil Description:
Dark Gray Slightly Clayed Sand
In Place Moisture:
7.5 Percent
Optimum Moisture:
10.4 Percent
Max. Dry Density:
114.1 P.C.F.
@ Test Locations The
Density & Penetrometer
Re��`` ' � �e the
D rlbo oton Meets
f�f 5t�aked Fou�ndOon
* en digs TaT.0 njo Natural Grade.
STA'fEOF
a. _.ft.0
i
t. Lucie County Building Department
aims . "starlylnho mlloway@yahoo.com
Moisture - IN, of Dry Weight
Ronald G. Keller, P.E.: 37293 / SI Lic. No.: 860 / Julie E. Keller, P.E.: 68366
``Comex 54756254
/3 0 � - aos�
Plant:
Begin Loading:
To Job:
Arrive Job:
Start Unload:
Finish Unload:
Leave Job:
Return Plant:
0 9: 2 1/ 1.1 t ) �_.
i_,
Customer Code: Customer Name: Customer Job Number:
INC 6 r. T).,7P GENE','� I!_ CO''TRPCT 3 y�,ERVICEIF' YN
Project Code: Project Name: Project P.O. Number
Ticket Date: Delivery Address:
1 ',776 D'UP,4q
Delivery Instructions:
D ly
Order Code / Date:
51 1 -17 02 / 26 1
Order P.O. Number.
Map Page: Map/Row/Column:
Dispatcher:
Ticket Number:
2,f: 7131 G 7 3
Due On Job:
Slump:
Truck Number:
Driver Number:
Driver Name:
End Use:
- 55
I o7.
5. d
1
tB I C) 19 2 i-3 %
RAY MORRIS'
I-"'- ) Sl-
1 1
AMOUNT
I
LOAD
QUANTITY I
CUMULATIVE
QUANTITY
ORDERED
QUANTITY
MATERIAL CODE
I
PRODUCTION DESCRIPTION
UOM
I I
UNIT PRICE
I
rEG
1. R, FUE-LI
. L i'2#31sI11E=ki C1
Cash Check # / Auth Code: Signature of Driver Receiving Cash: Cash Received:
Check
Comments:
J\sr
Notice: Our drivers will make every effort to place materials
Company assumes no responsibility for damages Inside curb i
terms of sale and delivery and accepts concrete as Is. Due'
control after delivery, this Company will not accept any repons
returned concrete. Buyers exceptions and claims shall be deE
within One business day after the receipt of materials. lllzm.
Total COD Order Amount to Collect
Without Standby Charges:
WATER ADDED: GAL YARDS IN DRUM:
. WHEN ADDED.
SIGNATURE
CURB LINE CROSSED AT OWNER'S/AGENT'S REQUEST:
SIGNATURE
U LOAD WAS TESTED BY: I
is customer designates, but the SPECIAL TERMS: Any water added Is at customers own risk. If water Is added on job, concrete strength
ty line. Customer agrees to the is no longer guaraqteed. WARNING: Product may cause skin and/or eye irritation. CAUTION: Material
tant factors which are out of our nay -be- rdqus7 to your safety and health. Please refer to the backside of this ticket for Irp-nirtant
the finished results. No credit for rjdmllbpq�.inforqEttlon,.ancl to the material safety data sheets for additional information.
ved unless made to us In writing AUTHO �IZED SIGCK T
68UNIVERSAL 1-,1 T, CJ( L 0 A,
INVOICE 11
This Delivery Ticket incorporates herein by reference Buyer's previously executed Credit Application, if any, Seller's Stand,,
Terms and Conditions, Seller's Quou , if any, and Seller's Order Confirmation "Auding limitations of warranties), as if fu
set forth on this Delivery Ticket ("Agi ent"). Seller will provide the Standard Te and Conditions upon request. Buyer agrf
that, unless otherwise noted on the front hereof, all quantities and items were delivered as indicated and further expressly agrees
pay in accordance with the Agreement.
AGGREGATE / CEMENT / CONCRETE PRODUCTS / FLY ASH
Aggregate products are naturally occurring materials including limestone, dolomite, granite, volcanic rock, sand, gravel, and otN
siliceous materials. Cement products .include Portland cement, masonry, pozzolan (Type IP), roof tile, and stucco. Concre'i
products include Portland cement and aggregate products including limestone, dolomite, granite, volcanic rock, sand, gravel, at
other siliceous materials. These products, including fly ash, may contain more than 0.025% crystalline silica.
Hazards: Freshly mixed wet cement and/or fly ash can cause eye irritation, skin and eye burns and allergic skin reactions
Dry concrete and aggregate dust may cause irritation to eyes, skin, and/or respiratory tract. Dust from handling
crushing, grinding, cutting and/or drilling may contain silica, which may cause silicosis and cancer if inhaled
If ingested, keep warm, at rest, and drink large amounts of water. Fly Ash may contain trace amounts of ammc
nia. Moisture can cause the ammonia to be released. Inhalation of ammonia can cause coughing and irritatio
or burns of the nose, throat and lungs. See physician. Health risk depends on duration and level of exposure.
Safety: Avoid contact with eyes and prolonged contact with skin.. Wear gloves, eye protection, and appropriate p.rotecti
clothing. Wash hands thoroughly with mild soap and water after handling. Avoid breathing dust. If exposed
dustabove recommended limits (see MSDS), wear suitable NIOSH-approved respiratory protection.
First Aid: In case of eye contact, immediately flush eyes with flowing water for 15 minutes. If dust is inhaled, move to fre
air. If wet cement contacts skin, rinse thoroughly with water. Get proper medical attention if irritation persists.
CEMEX, Memorial Hermann Tower
929 Gessner, Suite 1900
V7 combined Houston, Texas 77024
02/12 For .more information please visit www.cemexusa.com..
Este. ticket de entrega incluye como referencia al comprador (ya previamente ejecutada en su aplicaci6n de credito); cualqui r
termino estdndar, condiciones del vendedor, propuestas del vendedor y orden de confirmaci6n del vendedor (con l.imitaciones y
garantfas), como acuerdo total del ticket de entrega ("Contrato"). El vendedor proveera los t6rminos estandares y condiciones deu 1-
lados en caso de asf ser requeridos. Con este documento, el comprador acepta los mismos ya antes mencionados y que las cantidad s
y materiales fueron entregados como se expresa en el mismo. Acepta pagar el monto de acuerdo al contrato; al menos que se iden.i-
fique con una rota• al frente de este documento.
AGREGADOS / CEMENTO / PRODUCTOS DE CONCRETO / CENIZAS VOLANTES
Los productos de'agregados son materiales naturaley como piedra caliza, dolomita, granito, coca volednica, arena, gravy y otro:
materiales silicios. Los productos de cemento incluyen Cemento de tipo Portland, de albanilerfa, pozzolan (tipo IP), azulejo do
azotea y estuco. Los productos de concreto incluyen cemento Portland y productos de agregados como piedra caliza, dolomita
granito, roca volcdnica, arena, grava, y otros materiales silicios. Estos productos incluyen cenizas volantes (fly ash) la cual puede
contener mas de 0.025% de sil.icio cristalino.
Peligros: Mezcla de cemento fresco y/o cenizas volantes pueden causar irritaci6n en .los ojos, quemaduras en piel y ojos,
reacciones al6rgicas en la pie]. Concreto seco y polvo de agregados, pueden causar irritaci6n en los ojos, piel y/o et
la zona respiratoria. Polvo del manejo en el trituramiento, pulido, corte y/o perforaci6n puede contener materiale:
silicos, los cuales pueden causar silicosis pulmonar y cancer si son inhalados. En caso de ser ingeridos, mantenersf
en temperatura calida, reposar y tomar grandes cantidades de agua. Las cenizas volantes pueden contener amoniaco
Seguridad: La humedad puede causar la liberaci6n del amoniaco. La inhalaci6n del amoniaco puede causar toser, irritaci6n c
quemaduras en la nariz, garganta y pulmones. Acudir inmediatamente al medico. El riesgo en la salud depende er
]a duraci6n y el nivel de la exposici6n.
Seguridad: Evite el contacto con ojos y contacto prolongado con la piel. Use guantes, protecci6n en los ojos y ropal
Primeros adecuada para protecci6n. Lavese las manos con jab6n suave y agua despu6s del manejo de .materiales. Evite inhalar;
auxilios: polvos. Si se expone a polvos mds de los limites recomendados, use protecci6n respiratoria.
Primeros auxilios: En caso de contacto en los ojos, inmediatamente fluya agua en la parte afectada por 15 minutos.
Si se inhala polvo, exp6ngase a aire fresco. Si el cemento fresco tiene contacto con sus ojos, lavelos a fondo con
agua. Acuda a atenci6n medica inmediatamente si la irritaci6n continua.
CEMEX, Memorial Hermann Tower
929 Gessner, Suite 1900
V7 combinado Houston, Texas 77024
"1/12 Para mas informaci6n visita www.cemexusa.com.
t
cmcx 54756,249
Q.
Plant:
Begin Loading:
To Job:
Arrive Job;
Start Unload:
Finish. Unload:
Leave Job:
Return Plant:
Customer Code: Customer Name: gCustomer Job Number:
0:
Project Code: Project Name: Project P.O. Number:
Ticket Date: Delivery Address:
Delivery Instructions:
i
Order Code ! Date:
Order P.O. Number.
Map Page: Map/Row/Column:
Dispatcher:
Ticket Number:
Due On Job:
Slump:
Truck Number:
Driver Number:
Driver Name:
End Use:
LOAD CUMULATIVE ORDERED MATERIAL CODE PRODUCTION DESCRIPTION UOM UNIT PRICE AMOUNT
QUANTITY QUANTITY QUANTITY
Cash Check # / Auth Code: Signature of Driver Receiving Cash: Cash Received: _ Total COD Order Amount to Collect
Without Standby Charges:
Check
Charge /R /
Comments: \
WATER ADDED'. GAL YARDS IN DRUM:
_ WHEN ADDED.
a — SIGNATURE
CURB LINE CROSSED AT OWNER'S/AGENT'S REQUEST:
SIGNATURE
.' .
r ❑ LOAD WAS TESTED BY:
Notice: Our drivers will make every effort to place materials where the customer designates, but the SPECIAL TERMS: Any water added is at customers own risk. If water Is added on job, concrete strength
Company assumes no responsibility for damages inside curb or property line. Customer agrees to the is no longer guaranteed. WARNING: Product may cause skin and/or eye Irritation. CAUTION: Material
terms of sale and delivery and accepts concrete as Is. Due to important factors which are out of our may be hazardous to your, safety and health. Please refer to the backside of this ticket for Important
control after delivery, this Company will not accept any responsibility for the finished results. No credit for safety handling Information, and to the.' naterial safety data sheets for additional Information.
returned concrete. Buyers exceptions and claims shall be deemed waived unless made to us In writing AUTHORIZED"SIGNATUREE: '
within one business day after the receipt of materials, f
68UNIVERSAL i ':4E V 7i 1 :1 CUSTOMER
This Delivery Ticket incorporates,herei ' reference Buyer's previously exeautod."--lit Application, if any, Seller's Stand:
Terms and Conditions, Seller's Quotatic any, and Seller's Order Confirmation (ii ling limitations of warranties), as if fu
set forth on this Delivery Ticket ("Agreement"). Seller will provide the Standard Terms and Conditions upon request. Buyer agre
that, unless otherwise noted on the front hereof, all quantities and items were delivered as indicated and further expressly agrees
pay in accordance with tine Agreement.
AGGREGATE / CEMENT / CONCRETE PRODUCTS / FLY ASH
Aggregate products are naturally occurring materials including limestone, dolomite, granite, volcanic rock, sand, gravel, and otr�f
siliceous materials. Cement products include Portland cement, masonry, pozzolan (Type IP), roof tile, and stucco. Conerei
products include Portland cement and aggregate products including limestone, dolomite, granite, volcanic rock, sand, gravel, ar
other siliceous material's. These products, including fly ash, may contain more than 0.025% crystalline silica. -
Hazards: Freshly mixed wet cement and/or fly ash can cause eye irritation, skin and eye burns and allergic skin reactions
Dry concrete and aggregate dust may cause irritation to eyes, skin, and/or respiratory tract. Dust from handling
crushing, grinding, cutting and/or drilling may contain silica, which may cause silicosis and cancer if inhaled
If ingested, keep warm, at rest, and drink large amounts of water. Fly Ash may contain trace amounts of ammc
nia. Moisture can cause the ammonia to be released. Inhalation of ammonia can cause coughing and irritatio
or burns of the nose, throat and lungs. See physician. Health risk depends on duration and level of exposure.
Safety: Avoid contact with eyes and prolonged contact with skin. Wear gloves, eye protection, and appropriate protecti
clothing. Wash hands thoroughly with mild soap and water after handling. Avoid breathing dust. If exposed
dust above recommended limits (see MSDS), wear suitable NIOSH-approved respiratory protection.
First Aid: In case of eye contact, immediately flush eyes with flowing water for 15 minutes. If dust is. inhaled, move to fre
air. If wet cement contacts skin, rinse thoroughly with water. Get proper medical attention if irritation persists.
CEMEX, Memorial. Hermann Tower
929 Gessner, Suite 1900
V7 combined Houston, Texas 77024
02/12 For more information please visit www cemexusa com.
Este ticket de entrega inciuye como referencia al comprad.or (ya previamente ejecutada en su aplicaci6n de credito); cualqui r
t6rnuno estandar, condiciones del vendedor, propuestas del vendedor, y orden de confirmation del vendedor (con linutaciones y
garantias), como acuerdo iota] del ticket de enti ega-(Contr aic; ). Li v: ridedor proveerd los terminos estandaf6s y cundicivnes det i-
q p p y yq s
lados en taro de asi se.r re uerrdos. Con este docurnento, el com rador ace . to .los mismos a antes mencronados ue las c,antidad
y materiales fueron entregados como se expresa en el mismo. Acepta pagar el monto de acuerdo at contrcto; al menos que se iden i-
fique con una rota al frente de este documento.
AGREGADOS / CEMENTO / PRODUCTOS DE CONCRETO / CENIZAS VOLANTES
Los productos de agregados son materiales naturales como piedra caliza, dolomita, granito, coca volcdnica, arena, gravy y otro
materiales silicios. Los productos de cemento incluyen Cemento de tipo Portland, de albanileria, pozzolan (tipo IP), azulejo do
azotea y estuco. Los productos de concreto incluyen cemento Portland y productos de agregados como piedra caliza, dolomita,
granito, rota volcdnica, arena, grava, y otros materiales si.licios. Estos productos incluyen cenizas volantes (fly ash) la cual. puede
contener mas de 0.025% de silicio cristalino.
Peligros: Mezcla de cemento fresco y/o cenizas volantes pueden causar i.rritacion en los Ojos, quemaduras en piel y ojos, y
reactions aldrgicas en la piel. Concreto seco y polvo de agregados, pueden causar irritaci6n en los ojos, piel y/o en
la zona respiratoria. Polvo del manejo en el trituramiento, pulido, torte y/o perforacion puede contener materiales
61icos, los cuales pueden causar silicosis pulmonar y cancer si son inhalados. En caso de ser ingeridos, mantenerse
en temperatura cdlida, reposar y tomar grandes cantidades de agua. Las cenizas volantes pueden contener amoniaco.
Seguridad• La humedad puede causar la liberation del amoniaco. La inhalation del amoniaco puede causar toser, irritaci6n o'
quemaduras en la nariz, garganta y pulmones. Acudir inmecl.iatamente al medico. EI riesgo en la salud depende en
la duration y el nivel de la exposici6n.
Segu.ridad: Evite el contacto con ojos y contacto prolongado con la piel. Use guantes, protecci.6n en los ojos y
Primeros adecuada para protecci6n. Ldvese las manos con jab6n suave y agua despues del manejo de materiales. Evite in
auxilios: polvos. Si se expone a polvos mas de los limiter recomendados, use protection respiratoria.
Primeros auxil.ias: En caso de contacto en los ojos, inrnediatarnente fluya agua en la parte afectada por 15 minutos.
Si se inhala polvo, exp6ngase a aire fresco. Si el cemento fresco tiene contacto con sus ojos, lavelos a fondo con
agua: Acuda a atenci6n medica inmediatamente si la irritation continua.
CEMEX, Memorial Hermann Tower
929 Gessner, Suite 1900.
V7 conibinado Houston, Texas' 77024
02/12 Para mas information visita www.cemexusa.coni.
a
9
L�
S
Vrn
88
91'
00
m
mtQ
Planning & Development' ,rvices
Building & Code Regulation Division
2300 Virginia Ave
Fort Pierce, FL 34982
772-462-2165 Fax 772-462-6443
Request for 30 — Day Temporary Power Release
Date:"-? -a cl ' Permit,Number:
Property Address:
THE UNDERSIGNED HEREBY REQUEST RELEASE OF ELECTRICAL POWER TO THE ABOVE DESCRIBED PROPERTY,
FOR A PERIOD NOT TO EXCEED THIRTY (30) DAYS, FOR THE PURPOSE OF TESTING SYSTEMS AND EQUIPMENTS
IN PREPARATION FOR FINAL INSPECTION. IN CONSIDERATION OF APPROVAL OF THE REQUEST WE HEREBY
ACKNOWLEGE AND AGREE AS FOLLOWS:
1. This temporary power release is requested for the above state purpose only, and there will be no
occupancy of any type, other than that permitted by construction during this time period.
2. As witness by our signatures, we hereby agree to abide by all terms and conditions of this agreement,
including Building Division Policy, which is incorporated herein by reference.
3. All conditions and requirements listed in the attached document entitled "Requirements for 30 Day
Power for Testing" have been fulfilled and the premise is ready for compliance inspection.
4. All requests for an extension beyond 30 days must be made in writing to the Building Official stating
the reason for the request. Power maybe removed from the site and/or a Stop Work Order issued if
the Final Inspection has not been approved within 30 days. A fee of $100 will be required to lift the
Stop Work Order.
WE HEREBY RELEASE AND AGREE TO HOLD HARMLESS, ST LUCIE COUNTY, AND THEIR EMPLOYEES FROM ALL
LIABILITIES AND CLAIMS OF ANY TYPE OF NATURE WHICH MAY ARISE NOW OR IN THE FUTURE OUT OF THIS
TRANSACTION, INCLUDING ANY DAMAGE WHICH MAY BE INCURRED DUE TO THE DISCONNECTION
ELECTRICAL POWER IN THE EVENT OF VIOLATION OF THIS AGREEMENT.
OWNER SIGNAT
7 - ) 9 --.
DATE
CONTRACTOR SIGMTURE " DATE
ELECRICAYCZNTRACTOR SIGNATURE DATE
RECEIVED JUL 29 2013
St. Lucie County
Building and Zoning Department
Requirements for 30 Day Power for Testing
I. Form entitled "Request for 30-Day Temporary Power Release" must be fully executed and posted
in the Building Department record files prior to inspection.
II. Inspection Requirements:
1. _Address numbers shall be posted per county Ord. No. 7.05.09.
2. All entrances, exits, windows and garage doors must be lockable.
3. All circuits on exterior shall be terminated in a box with weatherproof cover. The same
applies to a disconnect. If circuits are at or above 7'6" from grade they may be capped with
wire nuts and taped.
4. All breakers must be installed. Any blank space must be closed by a breaker or approved
filler plates.
5. Interior Wiring: All receptacles, light fixtures and fans must be trimmed. Any fixture below
7'6" from the floor or mezzanine that is not available at the time of inspection must have an
Inviso plate installed. Fixtures at or above that height may be capped with wire nuts and
taped.
6. All smoke detectors must be installed.
7. Kitchen cabinets must be installed; any exception for special conditions or circumstances
must have an approval prior to scheduled inspection.
8. Sewer and water connections must be complete. Only well pumps are excluded from this
requirement.
9. Exterior construction must be complete and weather tight, including stucco, siding, roof and
soffit.
10. Permit work shall be substantially completed except for back orders, paint on exterior, carpet
and/or floor covering, pumps, air conditioners and driveway.
tj=mom-
insulation
a MASCO Comparry
CERTIFICATION OF INSULATION
R- - � -INSULATION INSTALLED -ON EXTERIOR WALLS
R- l g INSULATION INSTALLED IN CEILING AREAS
LEGAL: Lot Block
PERMIT
Sub -Division
a
JOB ADDRESS:- Lt G Du n Ei, PV .Gc« joc
GALE W/O: 4 D p g g S q-7 i
ATTESTED BY:
DATE: '7 - 3RECEIVED
JUL 3.1 280
PERMITTING
St. Lucie County FL
' 3601-A CROSSROADS PARKWAY FT. PIERCE, FL 34945
FT. PIERCE (772) 465-9191 • VERO BEACH (772) 589-1514 • STUART (772) 283-3151 • FAX (772) 489-6758
T
A- Ccmcx
/_9 0/- do 6-,9
54756431
�.'.-I .. ". "v, ."�,
a..+...�.rwa�..T�•'
G___..w.�..W.
Customer Code: Customer Name: Customer Job Number: Order Code / Date:
3t:jfjF, !t3{; DOYL-E FIA931ixR`f INC �,{:?{:j f:;,' {:;G,�:€.
Project Code; Project Name: Project P.O. Number: Order P.O. Number,
I NO PO
Ticket Date: Delivery Address: Map Page: Map/Row/Column:
t33;'0',S / 131 'r 7 17 , Ijrt•_]P;I€`d 1"CD : '"r _ 2, 7 228 1
Delivery Instructions: Dispatcher.
t. M T Y}WA Y EAST TO MAIN . THEN NORTH i 0 JOB SM i R 17. and Sr� � ►
Ticket Number:
I,
Due On Job:
Slump:
Truck Number:
Driver Number:
Driver Name:
End Use:
31 �.'1':.�
�.'•?!°S
pAY MO?" • C..',
1^
LOAD
QUANTITY
CUMULATIVE
QUANTITY
ORDERED
QUANTITY
MATERIAL CODE
PRODUCTION DESCRIPTION
UOM
UNIT PRICE
AMOUNT
'
MAR ���'1141Tnn F.b{II
tY S
O
1 47 1 ;
=Lacl- ��€ ��€�r,r�u ,
n
00
1.2027:£S)
I it€'.JIRO€\1M NTn-L CHARGE
Cash Check # / Auth Code: Signature of Driver Receiving Cash: Cash Received: Total COD Order Amount to Collect
Check •
Without Standby Charges:
Charge
Comments:
WATERADDED: GAL YARDS IN DRUM:
WHEN ADDED.
"I SIGNATURE
CURB LINE CROSSED AT OWNER'S/AGENT'S REQUEST:
SIGNATURE
❑ LOAD WAS TESTED BY:
Notice: Our drivers will make every effort to place materials where the customer designates, but the SPECIAL TERMS: Any water added is at customers own risk. If water Is added on job, concrete strength
Company assumes no responsibility for damages Inside curb or property line. Customer agrees to the is no longer guaranteed. WARNING: Product may cause skin and/or eye irritation. CAUTION: Material
terms of sale and delivery and accepts concrete as is. Due to important factors which are out of our may be hazardous to your safety and health. Please refer to the backside of this ticket for important
control after delivery, this Company will not accept any responsibility for the finished results. No credit for safety handling information, and to the material safety data sheets for additional information.
returned concrete. Buyers exceptions and claims shall be deemed waived unless made to us in writing AUTHORIZED SIGNATURE:
within one business day after the receipt of materials. O
66UNIVERSAL F)FIE I' TM"". .G-' PLANT LOADLOAD€`•i6_ls'/€ :I.
rj
PERMIT #: 56-SF-1443316
STATE OF FLORIDA APPLICATION #: AP1090523
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL DATE PAID:
SYSTEM FEE PAID:
CONSTRUCTION PERMIT
RECEIPT #:
DOCUMENT #: PR892485
CONSTRUCTION PERMIT FOR: OSTDS New
APPLICANT: Butch Holloway
PROPERTY ADDRESS: 4776 Dunn Rd Fort Pierce, FL 34983
LOT: 77 BLOCK:
PROPERTY ID #: 3403-502-0139-0000-1
SUBDIVISION: White City
[SECTION, TOWNSHIP, RANGE, PARCEL NUMBER]
[OR TAX ID NUMBER]
r
SYSTEM MUST BE CONSTRUCTED IN ACCORDANCE WITH SPECIFICATIONS AND STANDARDS OF SECTI0N--
381.0065, F.S., AND .CHAPTER 64E-6, E.A.C. DEPARTMENT APPROVAL OF SYSTEM DOES NOT GUARANTEE
`SATISFACTORY PERFORMANCE FOR ANY SPECIFIC PERIOD OF TIME. ANY CHANGE IN MATERIAL FACTS,„
' WHICH SERVED AS A BASIS FOR ISSUANCE OF THIS PERMIT, REQUIRE THE APPLICANT TO MODIFY THE
PERMIT APPLICATION. SUCH MODIFICATIONS MAY RESULT IN THIS PERMIT BEING MADE NULL AND VOID. --
ISSUANCE OF THIS PERMIT DOES NOT EXEMPT THE APPLICANT FROM COMPLIANCE WITH OTHER FEDERAL,'
STATE, OR LOCAL PERMITTING REQUIRED FOR DEVELOPMENT OF THIS PROPERTY.
SYSTEM DESIGN AND SPECIFICATIONS
T [ 900 1 GALLONS / GPD Septic CAPACITY
A [ ] GALLONS / GPD N/A CAPACITY
N [ ] GALLONS GREASE INTERCEPTOR CAPACITY [MAXIMUM CAPACITY SINGLE TANK:1250 GALLONS]
K [ ] GALLONS DOSING TANK CAPACITY [ ]GALLONS @[ ]DOSES PER 24 HRS #Pumps [ -•]
D [ 500 l SQUARE FEET SYSTEM
R [ l SQUARE FEET N/A SYSTEM
A TYPE SYSTEM: [ l STANDARD [ ] FILLED GC] MOUND [A
I CONFIGURATION: [ ] TRENCH [Xl BED [ ]
N
F LOCATION OF BENCHMARK: NAIL IN WOOD FENCE EL=14.55 NGVD (SEE SITE PLAN)
I ELEVATION OF PROPOSED SYSTEM SITE [ 18.001E INCHES FT ][ABOVE BELOW] BENCHMARK/REFERENCE POINT
E BOTTOM OF DRAINFIELD TO BE [ 18.001[ INCHES FT ][ABOVE BELOW] BENCHMARK/REFERENCE POINT
L
D FILL REQUIRED: [18.003 INCHES EXCAVATION REQUIRED: [ ] INCHES
O The licensed contractor installing the system is responsible for installing the minimum category of tank in accordance
with s. 64E-6.013(3)(f), FAC.
H
R
SPECIFICATIONS BY: Andrew R Gatewood. TITLE: Environmental Specialist II
APPROVED BY: TITLE: Environmental Specialist II St. Lucie CHD
s C n an
DATE ISSUED: 12/19/ 2 EXPIRATION DATE: 06/19/2014
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC Page 1 of 3
AP1090523 5EB65674
J
s STATE OF FLORIDA PERMIT #.
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
SITE EVALUATION AND SYSTEM SPECIFICATIONS
we
APPLICANT: r AGENT: bel mtre
LOT: BLOCK: SUBDIVISION:
PROPERTY ID # :�?j" " �(/Z�b/3�/-1J��� [ Section/Townshi Parcel No ." r Tax ID Number]
TO BE COMPLETED BY ENGINEER, HEALTH DEPARTMENT EMPLOYEE,OR OTHER QUALIFIED PERSON. ENGINEERS
MUST PROVIDE REGISTRATION NUMBER AND SIGN AND SEAL EACH PAGE OF SUBMITTAL. COMPLETE ALL ITEMS.
PROPERTY SIZE CONFORMS TO SITE PLAN: ji"] YES [ ] NO NET USABLE AREA AVAILABLE: 7 ACRES
TOTAL ESTIMATED SEWAGE FLOW: ® GALLONS PER DAY [RESIDENCES -TABLE 1/OTHER=TABLE23
AUTHORIZED SEWAGE FLOW: / GALLONS PER DAY [1500 GPD/ACRE OR 2500,GPD/ACRE]
UNOBSTRUCTED AREA AVAILABLE: Q SQFT UNOBSTRUCTED AREA REQUIRED: 1468 SQFT
BENCHMARK/REFERENCE POINT LOCATION:
ELEVATION OF PROPOSED SYSTEM SITE IS aNCHE�S'/FT] ABOVE/BELOW],4&NCHM41M/ EFERENCE POINT
THE MINIMUM SETBACK WHICH CAN BE MAINTAINED FROM THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES
SURFACE WATER:__L5 FT DITCHES/SWALES: % FT NORMALLY WET? [ ] YES [ ] NO
WELLS: PUBLIC: -'-?Or> FT LIMITED USE: / dd FT PRIVATE:_ rZ,5 FT NON -POTABLE: Sa FT
BUILDING FOUNDATIONS: '% FT PROPERTY LINES: // FT POTABLE WATER LINES:0 FT /
SITE SUBJECT TO FREQUENT FLOODING: [ ] YES [ ] NO 10 YEAR FLOODING? [ ] YES [ ] NO
10 YEAR FLOOD ELEVATION FOR SITE: FT MSL/NGVD SITE ELEVATION: FT MSL/NGVD
SOIL PROFILE INFORMATION SITE 1
MUNSELL #/COLOR TEXTURE DEPTH
TO
TO
TO
TO
TO
TO
TO
TO
TO
USDA SOIL SERIES:
SOIL PROFILE INFORMATION SITE 2
MUNSELL #/COLOR TEXTURE DEPTH
TO
TO
TO
TO
TO
TO
TO
TO
TO
USDA SOIL SERIES:
OBSERVED WATER TABLE: INCHES [ABOVE / BELOW] EXISTING GRADE. TYPE:[PERCHED / APPARENT]
ESTIMATED WET SEASON WATER TABLE'ELEVATION: INCHES [ABOVE,/ BELOW] EXISTING GRADE
HIGH WATER TABLE VEGETATION: [ ]'YES [ ] NO MOTTLING: [ ] YES [ ] NO DEPTH: INCHES
SOIL TEXTURE/LOADING RATE FOR'SYSTEM SIZING:
DRAINFIELD CONFIGURATION: [ ] TRENCH [ ]
1.
REMARKS/ADDITIONAL CRITERIA: 5, 0il tnqnn G
BED
DEPTH OF EXCAVATION: INCHES
t (SPECIFY)
D8 4015, 08/09 (Obsoletes previous editions'which may not be used) Incorporated: 64E-6.001,FAC
Page 3 of 4
J
STATE OF FLORIDA PERMIT NO.
? DEPARTMENT OF HEALTH DATE PAID:
ONSITE SEWAGE TREATMENT AND DISPOSAL FEE PAID:
SYSTEM RECEIPT #:
APPLICATION FOR CONSTRUCTION PERMIT
APPLICATION FOR: U6C,+G
New System [ ] Existing System [ ] Holding Tank [ ] Innovative
[ ] Repair [ ] Abandonment [ ] Temporary [ ]
APPLICANT: / G{,lf —� �J
AGENT: / j ��i1�J7UG�G c lk'-wAk" lam. TELEPHONE: /111
MAILING ADDRESS: / / 'T �'V . /V/i/./u/L/ a
TO BE COMPLETED BY APPLICANT OR APPLICANT'S AUTHORIZED AGENT. SYSTEMS MUST BE CONSTRUCTED
BY A PERSON LICENSED PURSUANT TO 489.105(3)(m) OR 489.552, FLORIDA STATUTES. IT IS THE
APPLICANT'S RESPONSIBILITY TO PROVIDE DOCUMENTATION OF THE DATE THE LOT WAS CREATED OR
PLATTED (MM/DD/YY) IF REQUESTING CONSIDERATION OF STATUTORY GRANDFATHER PROVISIONS.
PROPERTY INFORMATION
LOT: BLOCK: SUBDIVISION:( �Lt�G�I(�IS��7� PLATTED:
PROPERTY ID #:(L�� �� ZONING: -.I I/M OR EQUIVALENT: [ Y
PROPERTY SIZE: �(/�F' ACRES WATER SUPPLY: [ PRIVATE PUBLIC [ ]<=2000GPD [ ]>2000GPD
IS SEWER AVAILABLE AS PER 381.0065, FS? [ Y N DISTANCE TO SEWER: i ZOoo FT
PROPERTY ADDRESS: L177& L xnn Road
BUILDING INFORMATION [ RESIDENTIAL [ J COMMERCIAL
Unit Type of No. of Building Commercial/Institutional System Design
No Establishment Bedrooms Area Sqft Table 1, Chapter 64E-6, FAC
�-
2
3
4
[ ] Floor/Equipment Drains [ ] Other (Specify)
SIGNATURE:
DH 4015, 08/09 (Obsoletes p
Incorporated 64E-6.001, FAC
I
�u,� �? c•s sao9
s editions which may not be used)
DATE: /ZLZO he -
Page 1 of 4
STATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
SITE EVALUATION AND SYSTEM SPECIFICATION
APPLICATION # AP1090523
PERMIT # 56-SF-1443316
DOCUMENT # SE885674
APPLICANT: Butch Holloway
CONTRACTOR / AGENT: Layenture & Associates Inc'
LOT: 77 BLOCK: {
a
SUBDIVISION: White City ID#: 3403-502-0139-0000-1 i
J
TO BE COMPLETED BY ENGINEER, HEALTH DEPARTMENT EMPLOYEE, OR OTHER QUALIFIED PERSON. ENGINEERS MUST
PROVIDE REGISTRATION NUMBER AND SIGN AND SEAL EACH PAGE OF SUBMITTAL. COMPLETE ALL ITEMS.
PROPERTY SIZE CONFORMS TO SITE PLAN: [X]YES [ ]NO NET USABLE AREA AVAILABLE: 9.86 ACRES
TOTAL ESTIMATED SEWAGE FLOW: 300 GALLONS PER DAY [ RESIDENCES -TABLEI / OTHER -TABLE 2 ]
AUTHORIZED SEWAGE FLOW: 14790.01 GALLONS PER DAY [ 1500 GPD/ACRE I OR 2500 GPD/ACRE ]
T
UNOBSTRUCTED AREA AVAILABLE: 1000.00 SQFT UNOBSTRUCTED AREA REQUIRED: 750.00 SQFT
BENCHMARK/REFERENCE POINT LOCATION
ELEVATION OF PROPOSED SYSTEM SITE
NAIL IN WOOD FENCE EL=14.55 NGVD (SEE SITE PLAN)
18.00 [ INCHES / FT ] [ ABOVE / BELOW ] BENCHMARK/REFERENCE POINT
THE MINIMUM SETBACK WHICH CAN BE MAINTAINED`FROM THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES
SURFACE WATER: 117 FT DITCHES/SWALES: N/A FT NORMALLY WET: [ ]YES [X]NO
WELLS: PUBLIC: N/A FT LIMITED USE: N/A • FT PRIVATE: 80 FT NON -POTABLE: 60 FT ?.
BUILDING FOUNDATIONS: 14 FT PROPERTY LINES: 23 FT POTABLE WATER LINES: N/A PT,
I
SITE SUBJECT TO FREQUENT FLOODING? [ ]YES [X]NO 10 YEAR FLOODING? [ ]YES [X]N f
OJ
10 YEAR FLOOD ELEVATION FOR SITE: FT[ MSL / NGVD ] SITE ELEVATION: FT [ MSL / NGVD
SOIL PROFILE INFORMATION SITE 1
USDA SOIL SERIES:Winder loamy sand
Munsell #/Color Texture Depth
10YR 6/1 Fill 0 To 60
10YR 6/3 Clay 60 To 72
l SOIL PROFILE INFORMATION SITE 2
USDA SOIL SERIES:Winder loamy sand
Munsell #/Color Texture
Depth
1 OYR 6/1 Fill
0 To 60
10YR 6/3 Clay
60 To 72
+�_ 1
f
OBSERVED WATER TABLE: 24.00 INCHES [ ABOVE / BELOW ] EXISTING GRADE TYPE: [ PERCHED / APPARENT` ]l
ESTIMATED WET SEASON WATER TABLE ELEVATION: 24 INCHES [ ABOVE / BELOW ] EXISTING GRADE
-HIGH WATER TABLE VEGETATION: [ ]YES EX ]NO MOTTLING: [ ]YES [ ]NO DEPTH: INCHES
SOIL TEXTURE/LOADING RATE FOR SYSTEM SIZING: Fine Sand/0.60 DEPTH OF EXCAVATION: INCHES
DRAINFIELD CONFIGURATION: [ ] TRENCH [X ] BED [ ] OTHER (SPECIFY)
r REMARKS/ADDITIONAL CRITERIA
SITE EVALUATED BY:
bH 4015, 08/09 (Obsoletes previous editions whir -may not be
I
AP1090623
�Ounty Environmental Has
64E-6.001, FAC
EID1443316
DATE: 12/04/2012
Page 3 of 4
v 1.0.2
r
STATE OF FLORIDA PERMIT APPLICATION TO CONSTRUCT,
REPAIR, MODIFY, OR ABANDON A WELL
Permit No.
❑ Southwest
PLEASE FILL OUT ALL APPLICABLE FIELDS
Florida Unique ID
❑ Northwest
(*Denotes Required Fields Where Applicable)
Permit S' ul lion
❑ St. Johns River
r
(]South Florida
Thewater well contradorisresponsible for completing
this form and forwarding thepermit application to the
62-524 Quad No.
[]Suwannee River
appropriate delegated authority where applicable
❑ DEP
❑ Delegated Authority (If Applicable)
PM1UP Application No.
Delineation No.
1. LEWIS HOLLOWAY 4776 DUNN RD FORT PIERCE FL • 34981_ 216-4794
*Owner, Legal Name if Corporation *Address *City *State *ZIP Telephone Number
2. SAME AS ABOVE
*Well Location -Address, Road Name or Number, City
3.3403-502-0139-000-0 77
*Parcel ID No. (PIN) or Alternate Key (Circle One) ' Lot Block Unit
4, 05 36-S 40-E ST LUCIE WHITE CITY Check if 62-5240 Yes ❑✓ No
*Section or Land Grant *Township *Range *County Subdivision
5. A & C Welldrilling Inc 2273
*Water Well Contractor *License Number
16. 5017 Hickory Dr.
-Water Well Contractor's Address
772-465-0952 acwelldrill@bellsouth.net
*Telephone Number E-mail Address
Ft. Pierce
7. *Type of Work: ❑✓ Construction[] Repair ❑ Modification❑ Abandonment
8. *Number of Proposed. Wells
9. 'Specify Intended Use(s) of Well(s):
❑✓ - Domestic H
Landscape Irrigation ❑
❑ Bottled Water Supply Recreation Area Irrigation ❑
0 Public Water Supply (Limited Use/DOH) ❑
❑ Public Water Supply (Community or Non-Community/DEP)❑
❑ Class I Injection ❑
City
FI 34982
State ZIP
*Reason for Repair, Modification, or
Agricultural Irrigation Site Investigations
Livestock Monitoring
Nursery Irrigation ❑ Test
Commercial/Industrial ❑ Earth -Coupled Geothermal
Golf Course Irrigation H
HVAC Supply
HVAC Return
V Injection: ❑ Recharge ❑ Commercial/Industrial Disposal ❑ Aquifer Storage and Recovery ❑ Drainage
diation: ❑ Recovery ❑ Air Sparge ❑ Other (Describe) I Official Use
I Other (Describe)
0.*Distance from Septic System if <_ 200 ft. 75 ' 11. Facility Description
12. Estimated Start Date I —
13.*Estimated Well Depth. 70 ft. *Estimated Casing Depth 60 ft. .Primary Casing Diameter 2 in. Open Hole: From To ft.
14. Estimated Screen Interval: From 60 To 70 ft.
15.*Primary Casing Material: Black Steel anized PVC Stainless Steel
Not Cased er:
& Secondary Casing: Telescope Casing Liner Surface Casing Diameter in.
7. Secondary Casing Material: Black Steel A&Qlaw5p PVC Stainless Steel Other
18.*Method of Construction, Repair, or Abandonment: Auger Cable Tool Jetted
Rotary Sonic
Combination (Two or More Methods) Hand Driven (Well Point, Sand Point)
Hydraulic Point (Direct Push)
Horizontal Drilling Plugged by Approved Method Other (Describe)
19. Proposed Grouting Interval for the Primary, Secondary, and Additional Casing:
From To Seal Material ( Bentonite Neat Cement Other
From To Seal Material ( Bentonite Neat Cement Other
From To Seal Material ( Bentonite Neat Cement Other
)
From To Seal Material ( Bentonite Neat Cement Other
)
20. Indicate total number of existing wells on site / List number of existing unused wells on site d
21 *Is this well or any existingwell or water withdrawal on the owner's contiguous propertyy covered under a Consumptive/Water Use Permit (CUP/WUP)
- or CUP/WUP Application. Yes No If yes, complete the following: CUPNVUP No. District Well ID No.,
22. Latitude
Longitude
23. Data Obtained From: GPS Map ✓ Survey
I hereby certify that I will comply with the applicable rules of Title 40, Florida Administrative Code, and that a water
use pemdt or artificial recharge permit, if needed, has been or will be obtained prior to cammencement of well
construction. I further certify that all information provided in this application is accurate and that I will obtain
necessary approval from other fedeml, state, or cal govemments, if applicable. I agree to provide a well
completion repo t he District within 30 days ercempletion of the construction, repair, modification, or
abandonment o ed by this permit, orth emit expiration, whichever occurs first.
h
2273
-;S,79natuk of C
Rntractor *Lice se No.
BELOW THIS LINE - FOR OF,
Approval Granted By Issue Date
Fee Received
Receipt No.
Datum: NAD 27 NAD 83 WGS 84
I certify that I am the owner of the property, that the information provided is accurate, and that I am aware of my
responsibilities under Chapter 373, Florida Statutes, to maintain orpmpedy abandon this well; or, I certify that I am
the agent for the owner, that the information provided is accurate, and that I have informed the owneraf their
responsibilities as stated above. Owner consents to allowing personnel of this WMO or Delegated Authority access
to the well site during the construction, repair, modification, or abandonment authorized by this perm@.
of
-ation Date
Check No.
Ual
1-229-12
*Date
Hydrologist Approval
Initials
THIS PERMIT IS NOT VALID UNTIL PROPERLY SIGNED BY AN AUTHORIZED OFFICER OR REPRESENTATIVE OF THE WMD OR DELEGATED AUTHORITY. THE
PERMIT SHALL BE AVAILABLE AT THE WELL SITE DURING ALL CONSTRUCTION, REPAIR, MODIFICATION, OR ABANDONMENT ACTIVITIES.
DEP Form:
in62-532.400(1), F.A.C.
, 2010
Page 1
TFORM 405-10
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: HOLLOWAY GUEST HOUSE
Builder Name:
Street:
Permit Office:
City, State, Zip: ST. LUCIE COUNTY, FL,
Permit Number: I`
Owner:
Jurisdiction: RECEIVED
Design Location: FL, Fort Pierce
1. New construction or existing New (From Plans)
9. Wall T es 1800.0 s
YP ( qff•)
2019
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.0 1800.00 ftz
3. Number of units, if multiple family 1
b. N/A
c. N/A
R= ftz
4. Number of Bedrooms 2
d. N/A
R= ftz
R=
5. Is this a worst case? No
10. Ceiling Types (1754.0 sqft.)
ftz
Insulation Area
6. Conditioned floor area above grade (ftz) 1754
a. Under Attic (Vented)
b. N/A
R=19.0 1754.00 ftz
R= ftz
Conditioned floor area below grade (ftz) 0
c. N/A
R= ftz
7. Windows(124.0 sgft.) Description Area
11. Ducts
a. Sup: Attic, Ret: Attic, AH: Main
R ftz
6 205
a. U-Factor: Sgl, U=1.07 124.00 ftz
SHGC: SHGC=0.50
b. U-Factor: N/A f 2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
39.0 SEER:16.00
c. U-Factor: NIA ftz
SHGC:
d. U-Factor: N/A ft2
13. Heating systems
kBhAr Efficien cy
SHGC: '
a. Electric Heat Pump
34.0 HSPF:7.70
Area Weighted Average Overhang Depth: 2.000 ft.
Area Weighted Average SHGC: 0.500
14. Hot water systems
8. Floor Types (1754.0 sgft.) Insulation Area
a. Electric Tankless
Cap: 1 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1754.00 ftz
b. Conservation features
EF: 0.717
b. N/A R= ftz
None
c. WA R= ftz
15. Credits
Pstat
Glass/Floor Area: 0.071 Total Proposed Modified Loads: 27.47
Total
PASS
Standard Reference
Loads: 35.63
I hereby certify that the plans and specifications covered by
Review of the plans and
�T1i4E Sr9
TfiO
this calculation are in compliance with the Florida Energy
Code.
specifications covered by this
calculation indicates compliance
PREP
PREPARED BY:
with the Florida Energy Code.
ruse•' ' �'`' ' ••
Before construction is completed
- -. ,
DATE: " I I
this building will be inspected for
; C
p� ,
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
r r
with.the Florida Energy Code.
IW
D WET
OWNER/AGENT: 5/
BUILDING OFFICIAL:
DATE: / / T.-
DATE:
1115/201311:30 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 6
PROJECT
Title:
Building Type:
Owner:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
HOLLOWAY GUEST HOUSE Bedrooms: 2
User Conditioned Area: 1754
Total Stories: 1
1 Worst Case: No
Rotate Angle: 0
Cross Ventilation:
Whole House Fan:
Single-family
New (From Plans)
Address Type:
Lot #
Block/SubDivision:
PlatBook:
Street:
County:
City, State, Zip:
Street Address
ST. LUCIE COUNTY
ST. LUCIE COUNTY,
FL,
CLIMATE
v Design Location
IECC Design Temp
TMY Site Zone 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL_ST_LUCIE_CO_INTL 2 39 90
70
75 722
62 Low
BLOCKS
Number
Name
Area Volume
1
Blockl
1754 17540
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled Heated
1
Main
1754 17540 Yes 4
2
1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 250 ft 0
1754 ft2
0 0 1
ROOF
V #
Type
Roof Gable Roof
Materials Area Area Color
Solar
Absor.
SA Emitt
Tested
Emitt Deck Pitch
Tested Insul. (deg)
1
Hip
Metal 1900 ft2 0 ft2 Medium
0.96
No 0.9
No 0 22.6
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 300
1754 ft2
N N
CEILING
#
Ceiling Type
Space R-Value Area
Framing Frac
Truss Type
1
Under Attic (Vented)
Main 19 1754 ft2
0.11
Wood
1/15/2013 11:30 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 5
WALLS
#
Omt
Adjacent
To Wall
Space Cavity Width Height Sheathing Framing Solar
Type
Below
1
2
3
4
N
E
S
W
Exterior Concrete Block - Ext Insul Main
Exterior Concrete Block - Ext Insul Main
Exterior Concrete Block - Ext Insul Main
Exterior Concrete Block - Ext Insul Main
4 34 10
4 56 10
4 34 10
4 56 10
340 ft2 0
560 ft2
340 1`12
560 ft2
0 0.75
0 0.75
0 '0.75
0 0.75
0
0
0
0
DOORS
#
Omt
Door Type Space
Storms
U-Value Width
Ft In
Height
Ft In
Area
1
2
3
E
S
S
Insulated Main
Insulated Main
Insulated Main
None
None
None
0.460000 3
0.460000 3
0.460000 3
6 8
6 8
6 8
20 ft2
20 ft2
20 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
#
Wall
Omt ID Frame
Panes NFRC
U-Factor SHGC
Overhang
Area Depth Separation
Int Shade
Screening
1
2
3
4
5
N 1 Metal
E 2 Metal
S 3 Metal
W 4 Metal
W 4 Metal
Single (Tinted) Yes
Single (Tinted) Yes
Single (Tinted) Yes
Single (Tinted) Yes
Single (Tinted) Yes
1.07 0.5
1.07 0.5
1.07 0.5
1.07 0.5
1.07 0.5
20 ft2 2 It 0 in 6 ft 0 in
30 ft2 2 ft 0 in 6 ft 0 in
30 ft2 2 ft 0 in 6 It 0 in
24 f12 2 ft 0 in 6 It 0 in
20 ft2 2 It 0 in 6 ft 0 in
Drapes/blinds
Drapes/blinds
Drapes/blinds
Drapes/blinds
Drapes/blinds
None
None
None
None
None
INFILTRATION
#
Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Best Guess
0.000500
2300.38 126.288 237.503 0.36500 7.86904
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump None
HSPF: 7.7
34 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency
Capacity Air Flow
SHR Block
Ducts
1
Central Unit
None
SEER: 16
39 kBtu/hr 1170 cfm
0.75 1
sys#1
HOT WATER SYSTEM
#
System Type
SubType Location
EF Cap
Use SetPnt
Conservation
1
Electric
Tankless Exterior
0.66 1 gal 50 gal 120 deg
None
1/15/2013 11:30 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert #
Company Name
System Model # Collector Model # Area
Volume
FEF
None
None
ft2
DUCTS
V
— Supply
—
— Return —
Air
Percent
HVAC #
# Location R-Value Area
Location
Area Leakage Type
Handler
CFM 25
Leakage QN RLF
Heat Cool
1
Attic 6
205 ftz
Attic
15 ftz Default Leakage
Main
(Default) (Default) %
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan
HeatinHJan
HFe
Feb
Mar
Mar
WAPr
A r
Ma X Jun [X] Jul
May Jun [ ]Jul
X Au
Aug
Sep
rl Se
WOct
Oct
H
Nov
Nov
Dec
HDec
Ventin Jan
Feb
X Mar
A r
Ma [ Jun [ ] Jul
L
[ Au
L
Se
Oct
Nov
Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8
9
10
11
12
Cooling (V11D)
AM
78
78
78
78 78 78
78
78
80
80
80
80
PM
80
80
78
78 78 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78 78 78
78
78
78
78
78
78
PM
78
78
78
78 78 78
78
78
78
78
78
78
Heating(WD)
AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
1 /15/2013 11:30 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5
FORM 405-10
Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method
ADDRESS: PERMIT #:
ST. LUCIE COUNTY, FL,
MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details.
COMPONENT
SECTION
SUMMARY OF REQUIREMENT(S)
CHECK
Air leakage
402.4
To be caulked, gasketed, weatherstripped or otherwise sealed.
Recessed lighting IC -rated as meeting ASTM E 283. Windows and
doors = 0.30 cfm/sq.ft. Testing or visual inspection required.
Fireplaces: gasketed doors & outdoor combustion air. Must complete
envelope leakage report or visually verify Table 402.4.2.
Thermostat &
403.1
At least one thermostat shall be provided for each separate heating
controls
and cooling system. Where forced -air furnace is primary system,
programmable thermostat is required. Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts
403.2.2
All ducts, air handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and
sealed in accordance with Section 503.2.7.2 of this code.
403.3.3
Building framing cavities shall not be used as supply ducts.
Water heaters
403.4
Heat trap required for vertical pipe risers. Comply with efficiencies
in Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric) or shutoff (gas). Circulating system pipes insulated to =
R-2 + accessible manual OFF switch.
Mechanical
403.5
Homes designed to operate at positive pressure or with mechanical
ventilation
ventilation systems shall not exceed the minimum ASHRAE 62 level.
No make-up air from attics, crawispaces, garages or outdoors adjacent
to pools or spas.
Swimming Pools
403.9
Pool pumps and pool pump motors with a total horsepower (HP) of = 1
& Spas
HP shall have the capability of operating at two or more speeds. Spas
and heated pools must have vapor -retardant covers or a liquid cover or
other means proven to reduce heat loss except if 70% of heat from
site -recovered energy. Off/timer switch required. Gas heaters minimum
thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters
minimum COP= 4.0.
Cooling/heating
403.6
Sizing calculation performed & attached. Minimum efficiencies per
Tables 503.2.3. Equipment efficiency verification required. Special
equipment
occasion cooling or heating capacity requires separate system or
variable capacity system. Electric heat >10kW must be divided into two
or more stages.
Ceilings/knee walls
405.2.1
R-19. space permitting.
�— -a l•ti E,
1 /15/2013 11:30 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 77
The lower the EnergyPerformance Index, the more efficient the home.
ST. LUCIE COUNTY, FL,
1. New construction or existing
New (From Plans) 9. Wall Types
Insulation
Area
2. Single family or multiple family
Single-family a. Concrete Block - Ext Insul, Exterior
R=4.0
1800.00 ft2
b. N/A
R=
ft2
3. Number of units, if multiple family
1 c. N/A
R=
ft2
4. Number of Bedrooms
2 d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
5. Is this a worst case?
No a. Under Attic (Vented)
R=19.0
1754.00 ft2
6. Conditioned floor area (ft2)
1754 b. NIA
R=
ft2
7. Windows" Description
Area c. N/A
R=
ft2
a. U-Factor: Sgl, U=1.07
124.00 ft211. Ducts
a. Sup: Attic, Ret: Attic, AH: Main
R ft
6 205
SHGC: SHGC=0.50
b. U-Factor: N/A
ft2
SHGC:
12. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: N/A
ft2 a. Central Unit
39.0
SEER:16.00
SHGC:
d. U-Factor: N/A
ft2 13. Heating systems
kBtu/hr
Efficiency
SHGC:
a. Electric Heat Pump
34.0
HSPF:7.70
Area Weighted Average Overhang Depth:
2.000 ft.
Area Weighted Average SHGC:
0.500
8. Floor Types
Insulation Area 14. Hot water systems
Cap: 1 gallons
a. Slab -On -Grade Edge Insulation
R=0.0 1754.00 ft2 a. Electric
EF: 0.66
b. N/A
R= ft2
b. Conservation features
c. NIA
R= ft2
None
15. Credits _
Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building ' "
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features. ,
Builder Signature: �,��� Date: j-/5-,/3
Address of New Home: 76 h"'d ; / City/FL Zip: y9 k1
��O��FIE ST,gpFO�+
# fi
coD WE'T
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's
support staff.
'*Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software
-- wrightsoft®
Project Summary Job:
a
Entire House By:
QUICK CALCS, INC.
317 ST. LUGE LN., FT. PIERCE, FL34946 Phone: 772-466-6799 Fax 772-46&6796 Email: QUICKCALCSc@AOL.COM
For.
Notes:
HOLLOWAY GUEST HOUSE
ST. LUCIE COUNTY, FL
Weather: Fort Pierce, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 42 OF Outside db 90 OF
Inside db 70 OF Inside db 75 OF
Design TD 28 OF Design TD 15 OF
Daily range L
Relative humidity 50 %
Moisture difference 61 gr/lb
Heating Summary
Structure 17929
Ducts 0
Central vent (107 cfm) 3302
Humidification 0
Piping 0
Equipment load 21231
Infiltration
Method
Construction quality
Fireplaces
Sensible Cooling Equipment Load Sizing
Btuh
Structure
28308
Btuh
Btuh
Ducts
0
Btuh
Btuh
Central vent (107 cfm)
1769
Btuh
Btuh
Blower
0
Btuh
Btuh
Btuh
Use manufacturer's data
n
Rate/swing multiplier
0.95
Equipment sensible load
28573
Btuh
Simplified
Average
0
Heating Cooling
Area (ft2)
1754
1754
Volume (ft3)
15804
15804
Air changes/hour
0.38
0.20
Equiv. AVF (cfm)
100
53
Heating Equipment Summary
Make
Trade
Model
AHRI ref no. n/a
Efficiency
Heating input
Heating output
Temperature rise
Actual airflow
Air flow factor
Static pressure
Space thermostat
100 EFF
0 Btuh
21231 Btuh
15 OF
1300 cfm
0.073 cfm/Btuh
0 in H2O
Latent Cooling Equipment Load Sizing
Structure
5801
Btuh
Ducts
0
Btuh
Central vent (107 cfm)
4483
Btuh
Equipment latent load
10284
Btuh
Equipment total load
38857
Btuh
Req. total capacity at 0.70 SHR
3.4
ton
Cooling Equipment Summary
Make. Lennox
Trade 14ACX SERIES
Cond 14ACX-041-230*
Coil CBX27UH-048-230*++TDR
AHRI ref no. 3869097
Efficiency 13.0 EER, 16 SEER
Sensible cooling
27300
Btuh
Latent cooling
11700
Btuh
Total cooling
39000
Btuh
Actual air flow
1300
cfm
Air flow factor
0.046
cfm/Btuh
Static pressure
0
in H2O
Load sensible heat ratio
0.75
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
t Wri htso$t° 2012-Deo-2611:44:22
RightSuite® Universal 2012 12.0,07 RSU08101 Page 1
ACM ...Quick CalcsMocuments\Wrightsoft HVACIHOLLOWAY GUEST HOUSE. rup Calc = MJ8 Front Door faces:
- wrightsoft® Right-J® Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By:
317 ST. LUCIE LN., FT. PIERCE, FL34946 Phone: 772-466-6799 Fax 772-466.6796 Email: QUICKCALCS@AOL.COM
1
Room name
Entire House
MASTER BEDROOM
2
Exposed wall
178.0 ft
40.0 ft
3
Room height
9.0 ft d
9.0 ft heat/cool
4
5
Room dimensions
Room area
1756.0 ft2
1.0 x 303.0 ft
303.0 ft2
Ty
Construction
U-value
Or
HTM
Area (ft2)
Load
Any (ft2)
Load
number
(Btuh/W-*F)
(Btuh/ft2)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N!P/S
Heat
Cool
6
W
13A-4ocs
0.143
ne.
4.00
2.55
495
466
1866
1186
171
171
685
436
1Aclom
1.270
ne
35.56
70:43
9
0
320
634
0
0
0
0
1A-clom
A.270
. he
35.56
70.43
.20
0
. 711
1409
_ 0
.0
.. 0
D
V�
13A-4ocs
0.143
se
4.00
2.55
306
268
1073
682
135
115
459
292
11
{-C
�D
IA-clom
1.270
se
35.66
70.95
20
0
726
1448
20
0
726
1448
11 DO
0.390
se
10.92
11.31
18
18
192
199
0
0
0
0
W
13A-flocs
0.143
sw
4.00
_
2.55
495
_
426
1708
1086
54
34'
, ,
135
86
m
1.670
sw
46.76
43.21
20
0
954
881
20
0
954
881
[�10A
D11
IA-c1om
1.270
sw
35.56
70.95
30
0
1067
2128
0
0
0
0
DO
0.390
sw
10.92
11.31
IS'
18
.198
205
0
- 0
_ 0
0
13A-4ocs
0.143
nw
4.00
2.55
306
258
1032
656
0
0
0
0
1A-clom
1.270
nw
35.56
70.43
30
0
1067
2113
0
0
0
0
D
11DO
166-19md
0.390
_ 0.049
nw
-
10.92
1.37
11.31
2.57
18
1756
18
_ ' 1756
_ .198
2409
205
4517
0,
303
0
303
0
416
0
779
C
F
21A-20c
s
0.027
-
0.76
0.00
1756
1756
1328
0
303
303
. _
229
0
6
c) AE D e)cursion
250
-102
Envelope loss/gain
14848
17600
3603
3820
12
a) Infiltration
3080
868
692
195
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
8
184D
0
0
Appliances/other
8000
0
Subtotal (lines 6 to 13)
17929
28308
4295
4015
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
124
734
14
Subtotal
17M
28308
4419
4749
15
Duct loads
0%
0%
0
0
-0%
00/0
0
0
Total room load
17929
28308
1
1 4419
4749
Air required (cfm)
1300
1300
320
218
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrightscWt- 2012-Deo-26 11:44:22
ACCARightSuite@ Universal 2012 12.0.07 RSU03101 Page 1
...Quick Calcs\Documents\Wrightsoft HVAC\HOLLOWAY GUEST HOUSE. rup Calc = MJS Front Door faces:
-- wrightsoft, Right-JO Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By.
317 ST. LUCIE LN., FT. PIERCE, FL34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM
1
Room name
WIC
WIC 2
2
Exposed wall
6.0 ft
0 ft
3
Room height
9.0 ft heat/cool
9.0 ft heatfcool
4
5
Room dimensions
Room area
6.0 x 6.0 ft
36.0 ftz
6.0 x 6.0 ft
36.0 ftz
Ty
Construction
U-value
Or
HTM
Area (ft-)
Load
Area (ftz)
Load
number
(Btuh/ftz_°F)
(Btuh/ftz)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/PIS
Heat
Cool
Gross
N/P/S
Heat
Cool
6.W
93A-4ocs
0.143
ne
4.00
2.55
54
54
216
137
0
0
0
0
1A-clom
1.270
ne
35.56
M43
0
0
0
0
0
0
0
0
1A-clom
1:270
ne
35.56
70.43
0
0
. 0
0
_0
0
0
0
�l
13A-4ocs
0.143
se
4.00
2.55
0
0
0
0
0
0
0
0
11
I-G
:D
IA-c1om
1.270
se
35.56
70.95
0
0
0
0
0
0
0
0
11 DO
0.390
se
10.92
11.31
0
0
0
0
0
0
0
0
WI
13A-4ocs
0.143
sw
4.00
2.55
0
0
0
0
0
0
0
0
_
10A-m
1.670
sw
46.76
43.21
0
0
0
0
0
0
0
0
1Aclom
1.270
sw
35.56,
70.95
0
0
0
0
0
0
0
0
11DO
0.390
sw
10.92
11.31
0
0
0
. 0'.
_ 0-
_0'
0
0
VU
13A-4acs
0.143
nw
4.00
2.55
0
0
0
0
0
0
0
0
IA-c1om
1.270
rw
35.56
70.43
0
0
0
0
0
0
0
0
11 DO
0.390
nw
10.92
11.31
0
0
0
0
0
0
0
0
C .
16B719md..'_
0.049
-
1.37
2.57
36
36
49
93,
` 36
36
49
.93
F
21A-20c
0.027
-
0.76
0.00
36
36
27
0
36
36
27
0
6
c) AED e>cursion
-6
-2
Envelope loss/gain
293
224
77
90
12
a) Infiltration
104
29
0
0
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
0
Subtotal (lines 6 to 13)
397
253
77
90
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
57
339
14
Subtotal
397
253
134
429
15
Duct loads
-0%
0%
0
0
-0%
0%
0
0
Total room load
397
253
134
429
Air required (cfm)
291
12
10
20
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
Wrlght90ft® 2012-Dec-2611:44:22
RightSuite® Universal 2012 12.0.07 RSU08101 Page 2
ACCA _„Quick Calcs0ocumentslWrightsoft HVAC\HOLLOWAY GUEST HOUSE. rup Calc = MJ8 Front Door faces:
-�- wrightsofts Right-J® Worksheet Job:
Entire House Date:
By:
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL34946 Phone: 772-466-6799 Fax 772-4668796 Email: QUICKC4LCS@PAL.COM
1
Room name
MASTER BATH
HALL
2
Exposed wall
9.0 ft
4.0 ft
3
Room height
9.0 ft heat/cool
9.0 ft heat/cool
4
Room dimensions
15.0 x 9.0 ft
4.0 x 28.0 ft
5
Room area
135.0 ft2
112.0 ft'
Ty
Construction
U-value
Or
HTM
Area (ftz)
Load
Area (ft2)
Load
number
(Btuh/ftz-°F)
(Btuh/ft2)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
W
13A-4ocs
0.143
ne
4.00
2.56
81
72
288
183
0
0
0
0
�-G
1A-glom
1.270
ne
35.56
7OA3
9
0
320
634
0
0
0
0
�--G
1A-glom
1.270
. ne
35.56
. 70.43
0
0
0
0
0
0
0
0
�j
13A-4ocs
0.143
se
4.00
2.55
0
0
0
0
36
18
74
47
11
I-G
�- D
IA-clom
1.270
se
35.56
70.95
0
0
0
0
0
0
0
0
11 DO
0.390
se
10.92
11.31
0
0
0
_ 0
18
18
192
199
W
13A-4ocs
0.143
sw
4.00
2.55
0
0
•,
0
0
0
0
0
Oi
10A m
1.670
sw.
46.76
43.21
0
0
0
0
0
0
0
0.
IA-clom
1.270
sw
35.56
70.95
0
0
0
0
0
0
0
0
11130
0.390
sw
10.92
11.31..
0
0
0
0
0
0
0
0
Val
13A-flocs
0.143
nw
4.00
2.55
0
0
0
0
0
0
0
0
�L_Gp
1A-clom
1.270
nw
35.56
70.43
0
0
0
0
0
0
0
0
11 DO"
0.390
nw
10.92
11.31
0
0
0
0
0
0
0
0
C
16B-19md
0.049
-
1.37
2.57
135
135'
185
347
112
112
154
288
F
21A-20c
0.027
-
0.76
0.00
135
135
102
0
112
112
85
0
6
c) AE D e>cursion
-26
-86
Envelope loss/gain
896
1139
504
448
12
a) Infiltration
156
44
69
20
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
4
920
Appliances/other
0
2000
Subtotal (lines 6 to 13)
1051
1183
573
3387
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
86
508
-573
-3387
14
Subtotal
1137
1691
0
0
15
Duct loads
-0%
0%
0
0
-0%
00/0
0
0
Total room load
1137
1691
0
0
Air required (cfm)
82
78
Ol
0
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
aNre htso#t' 2012-Deo-2611:44:22
9 Right -Suite® Universal 2012 12.0.07 RSU08101 Page 3
ACCA ,,.Quids Calcs\DocumentslWrightsoft HVAC\HOLLOWAY GUEST HOUSE. rup Calc = MJ8 Front Door faces:
-�- wrightsoft° Right-J® Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By.
317 ST. LUGE LN., FT. PIERCE, FL34946 Phone: 772-466-6799 Fax 772-466Z796 Email: QUICKCALCS@AOL.COM
1
Room name
BEDROOM 2
BATH
2
Exposed wall
29.0 ft
0 ft
3
Room height
9.0 ft heat/cool
9.0 ft heat/cool
4
5
Room dimensions
Room area
15.0 x 14.0 ft
210.0 ft2
10.0 x 6.0 ft
60.0 ft2
Ty
Construction
U-value
Or
HTM
Area (W)
Load
Area (ft2)
Load
number
(Btuh/ft2-°F)
(Btuh/ft2)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/PIS
Heat
Cool
Gross
N/P/S
Heat
Cool
6
W
13A-4ocs
0.143
ne
4.00
2.55
D
0
0
0
6
0
0
0
IA-clom
1.270
ne
35.56
7043
0
0
0
0.
0
0
0
0
1A-clom
1.270
_ne
35.56
70.43
0
0
0
0
,0
.0,
0
0
VIJ
13A-4ocs
0.143
se
4.00
255
135
135
541
344
0
0
0
0
11
IL_-G
p
1A-clom
1.270
se
35.56
70.95
0
0
0
0
0
0
0
0
1100
0.390
se
10.92
11.31
0
0
0_
0
0_
0
0
0
W
13A-4ocs
0.143
sw
4.00
2.55
125
96
384
244
D
0
0
0
10A-m
1.670
sw
46.76
43.21
0
0
0
0
0
0.
0
0
1A-clom
1,270
sw
35.56
70.95
30
0
1067,
2128
0
0
.0
0
11 DO
0.390
sw
10.92
11.31
0
0
0
0'
0
.0
0
0
V�J
13A-4ocs
0.143
nw
4.00
2.55
0
0
0
0
0
0
0
0
�G
�D
IA-clom
1.270
nw
35.56
70.43
0
0
0
0
0
0
0
0
11 DO
0.390
nw
10.92
11.31
0
0
0
0_
0,
0
0
0
C
16B-19md,
0.049
-
1.37
2.57
210
_ 210
288
540
60
60
82
154
F
21A-20c
0.027
-
0.76
0.00
210
210
159
0
60
60
45
0
6
c) AED e)cursion
687
-4
Envelope loss/gain
2439
3944
128
151
12
a) Infiltration
502
141
0
0
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
0
Subtotal (lines 6 to 13)
2940
4085
128
151
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
134
790
57
339
14
Subtotal
3074
4875
185
489
15
Duct loads
-00/0
0%
0
0
-0%
0%
0
0
Total room load
3074
4875
185
489
Air required (cfm)
223
2241
13
22
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
Wri htsoft" 2012-Deo-2611:44:22
9 RightSuite® Universal 2012 12.0.07 RSU08101 Page 4
.EGA .,,Quick Calcs\Documents\Wrightsoft HVAC\HOLLOWAY GUEST HOUSE. rup Calc = MJ8 Front Door faces:
- wrightsoft, Right-J® Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By.
317 ST. LUCIE LN., FT. PIERCE, FL34946 Phone: 772-466-6799 Fax 772-466.6796 Email: QUla<C4LCS@AOL.COM
1
Room name
CLOSET
LAUNDRY
2
Exposed wall
6.0 ft
9.0 ft
3
Room height
9.0 ft heat/cool
9.0 ft heaUcool
4
Room dimensions
5.0 x 6.0 ft
15.0 x 9.0 ft
5
Room area
30.0 W
135.0 ft2
Ty
Construction
U-value
Or
HTM
Area (ft')
Load
Area (ft2)
Load
number
(Btuh/ft2L-°F)
(Btuh/ft2)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
W-
13A-4ocs
0.143
ne
4.00
2.55
0
0
0'
0
0
0
0
0
[��-G
1Ac1om
1,270
ne
35.56
70.43
0
0
0
0
0
0
0
0
G
1Ac1om
1.27.0
ne.
35.56
70.43
0
0
0
0
0
_0'.'
0
0
V
13A-4ocs
0.143
se
4.00
2.55
0
0
0
0
0
0
0
0
11
I-�
�-D
1A-c1om
1.270
se
35.56
70.95
0
0
0
0
0
0
0
0
11-DO
0.390
se
10.92
11.31
0-
0
0
0
0-
0
0
W
13A-4ocs
0.143
sw
4.00
2.65
54
54
216
137
-0
81
63
252
160
10A-m
1.670
sw
46.76
43.21
0
0
0
0
0
0
0
0
1Aclom
1,270
sw
35.56
70.95
0
0-
0
0
0
0
0
0
11'D0
0.390
sw
10.92
11.31
0
0
0
0
18
18
198
205
V�!
13A-4ocs
0.143
nw
4.00
2.55
0
0
0
0
0
0
0
0
JIA-c1om
1.270
nw
35.56
70.43
0
0
0
0
0
0
0
0
11D0
0.390
nw
1092
11.31
0
0
0
0
0
0
0
0
C
16B-19md
0.049
-
1.37
2.57
30
30
41
77
135
135
185
347
F
21A-20c
0.027
-
0.76
0.60
30
30
23
0
135
135
102
0
6
c)AEDercursion
-0
-08
Envelope loss/gain
280
209
737
644
12
a) Infiltration
104
29
156
44
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
2000
Subtotal (lines 6 to 13)
384
238
893
26BB
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
76
452
14
Subtotal
384
238
969
3140
15
Duct loads
-0°h
0%
0
0
-0%
0%
0
0
Total room load
384
238
969
3140
Air required (cfm) 128
11
70
144
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
wrightsoft^ 2012-Deo-2611:44:22
Right Suite@ Universal 2012 12.0.07 RSU08101 Page 5
ACCA ...Quick CalcsMocumentsWrightsoft HVAC\HOLLOWAY GUEST HOUSE. rup Calc = MJ8 Front Door faces:
- wr•ightsofte Right-J® Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By
317 ST. LUCIE LN., FL PIERCE, FL34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM
1
Room name
LIVING/KITCHEN
2
Exposed wall
75.0 ft
3
Room height
9.0 ft heat/cool
4
Room dimensions
1.0 x 699.0 ft
5
Room area
699.0 ftz
Ty
Construction
U-value
Or
HTM
Area (ft)
Load
Area
Load
number
(Btuh/ftz-°F)
(Btuh/ftz)
or perimeter (ft)
(Btuh)
or perimeter
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
W
13A-4ocs
0.143
ne
4.00
2 55
189
169
677
430
1A-clom
1,270
ne
35.56
70.43
0
0
0
0
-
1A-61om _ .;
1.270
. ne
35.56
70.43
20
_ 0
711
1409,
0.143
se
4.00
2.55
0
0
0
0
11
tj13A-flocs
1Ac1cm
1.270
se
35.56
70.95
0
0
0
0
11 DO,
0.3�
se
10.92
11.31
0
0
D
0
IW
13A-4ocs
0.143
sw
4.00
2.55'
180
180
721
458
10A-m
1.670
sw
46.76
43.21
0
0
0
0
1Ao1om
1.270
sw
35.56
70.95
0
0
0.
0
11D0
0.390
sw
10.92
, 11.31
0
0
0
,°. 0
.
VIJ
13A-1ocs
0.143
nw
4.00
2.55
306
258
1032
656
��Gp
1Ac1om
1.270
nw
35.56
70.43
30
0
1067
2113
11 DO
0.390
nw
10.92
11.31
18
18
198
205
C . � .
16B-19md
0.049
-
1.37
2.57
- ,
699
699
959
1798
F
21A-20c
0.027
-
0.76
0.00
699
699
528
0
6
c) AED e)cursion
-136
Envelope loss/gain
5893
6933
12
a) Infiltration
1298
366
b) Room ventilation
0
0
13
Internal gains: Occupants @ 230
4
92D
Appliances/other
4000
Subtotal (lines 6 to 13)
7191
12219
Less external load
0
0
Less transfer
0
0
Redistribution
38
226
14
Subtotal
7229
12445
15
Duct loads
-0°h
0%
0
0
Total room load
7229
12445
Air required (cfm)
524
572
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
wri htsoft' 2012-Deo-2611:44:22
9 RightSuite® Universal 2012 12.0.07 RSU08101 Page 6
ACCA ...Quick Calcs\Documents\Wrightsoft HVACIHOLLOWAY GUEST HOUSE. rup Calc = MJ8 Front Door faces:
4451 ST. LUCIE BLVD.
FORT PIERCE,, FL 34946
...... . ----
P*7
-AAA, —r, "'K� j - ft— V='� PHONE: (772) 409- 10 10
...........
A.FL0RI0AC0FRP--0RA7r1 N' FAX: (772) 409-1020
TRUSS ENGINEERING
BUILDER: -Tracy Cullen Repairs
PROJECT: Ho/%way Guest House
MODEL: 0
Job# 55256 Lot# Parcel#
Master# 0
REVISIONS: DISTRIBUTION: December.10, 2012
A-t ROOF'.
TRUSSES
AFLORIDA CORPORATION
Location Information
Contractor / Builder: TRACY CULLY REPAIRS
Project Name:
Project Address:
Lot #
Block #
Model #
Subdivision:
HOLLOWAY GUEST HOUSE
4776 DUNN ROAD FORT PIERCE
Design Instructions
Design Criteria: ASCE 7-10 Wind
Computer Program Used: MITEK INDUSTRIES
Truss Company: Al Roof trusses Ltd
Loading Instructions
ROOFLOAD
Top Chord Live Load
20.0
Top Chord Dead Load
10.0
Bottom Chord Live Load
0.0
Bottom Chord Dead Load
10.0
Total Load 40.0
Duration Factor 1.25
4451 St. Luci Blvd. / Ft. Pierce, FI. 34946
772-409-1010 / 800-525-0126 / 772-409-1020 (fax)
160 MPH
Job Number: 55256
Occupancy:
SFR
County:
ST. LUCIE
FLOOR LOAD
Top Chord Live Load 0.0
Top Chord Dead Load 0.0
Bottom Chord Live Load 0.0
Bottom Chord Dead Load 0.0
Total Load 0.0
Duration Factor 0.0
As witness my seal, I hereby certify that this serves as a cover sheet in conformance with Chapter 61 G15-31 Section 003
of the Florida Board of Professional Regulation. This package includes a truss index sheet and truss drawings.
Julius Lee, PE / Florida Certification Number 34869/
1109 Coastal Bay, Boynton Beach, FL 33435
12/10/2012
�uS S.
\ ' �\GEN,SF'
* N 34869 * `
� W =
73
STATE OF \�411�
"tORIDP-
/ON;Ak-
1109 COASTAL BAY
BOYNTON BC,FL 33435
The seal on this index sheet indicates acceptance of professional
engineering responsibility solely for the Truss Design Drawings
listed below and attached. The suitability and use of each
component for any particular building is the responsibility of the
Building Designer, per ANSI/TPI 1-2002 Section 2 and
ANSI/TPIM/TCA Section 2.
The identity of the structural Engineer of Record did not exist as
of the seal date per section 61 G15-31.003(5a) of the Florida
Administrative Code.
A-1 ROOF
MM TRUSSES
AFLORIDACORPORATION
4451 St. Luc! Blvd. / Ft. Pierce, FI. 34946
772-409-1010 / 800-525-0126 / 772-409-1020 (fax)
The grades of all lumber used in those products manufactured by A-1 Roof Trusses shall be equal to or greater than the grade noted in the
drawings prior to cutting. The design values of visually graded lumber shall be as set forth in particular grading agency publications. To the extent
published design values are changed, A-1 Roof Trusses will incorporate such changes for newly permitted projects only. A-1 Roof Trusses
otherwise makes no warranty or representation as to lumber grade of design values.
TRUSS
TRUSSID
A01G
A0131973
A02
A0131974
A03
A0131975
A04
A0131976
A05
A0131977
A06
A0131978
A07G
A0131979
1301G
A0131980
CA
A0131981
CJ3
A0131982
CJ5
A0131983
HC5
A0131984
HJ7
A0131985
J7
A0131986
PA
A0131987
V12
A0131988
V14
A0131989
V4
A0131990
V8
A0131991
12/10/2012
Julius Lee, PE / Florida Certification Number 34869
Seal Applied to the Right
Job Number: 55256
Index Sheet for Drawings
ENS,�,
J.du
9
33
Luz
STATE OF �.FLORIDP`.•''
0NI111ALI1E\\��
1109 COASTAL BAY
BOYNTON BC,FL 33435
A01
55256 A01 G HIP TRUSS
Al ROOF TRUSSES, FORT PIERCE, FL 34946
_-2-4-10 3-9-14 7-0-0 12-0-14
2-4-10 3-9-14 3-2-2 5-0-14
I 1 1
1.350 s 5 Sep 27 2012 Print
I D:Sf937139GsZkfNbV2'
600 = 6x10 =
1.5x4 II 3x8 = 5x6 WB= 1.5x4 11
5.00 12 4 24 25 5 26 27 6 7 28 8 29 30 9
1 ,x4
,az4 i
3
10
3,
1
Scale=1:62.9
of
1 _ Ch
12I�
17 31 32 16 33 34 15 35 36 14 37 38 13
3x8 = 3x4 = 7x10 MT20H= 1.5x4 II 7x10 MT20H= 3x4 = 3x8 =
3-9-14 7-0-0 , 12-0-14 17-0-0 21-11-2 27-0 0 30-2-2 34-0-0
3-9-14 3-2-2 5-0-14 4-11-2 4-11-2 5-0-14 3-2-2 3-9-14
Plate Offsets MY):[2:0-4-210-1-81,[4:0-7-12,0-2-81, [7:0-3-0,Edgel, [9:0-7-12,0-2-81, [11:0-4-2,0-1-81
LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.99 Vert(LL) 0.73 15 >561 360 MT20 244/190
TCDL 10.0 Lumber Increase 1.25 BC 0.98 Vert(TL) -1.27 14-15 >321 240 MT20H 187/143
BCLL 0.0 Rep Stress Incr NO WB 0.95 Horz(TL) 0.30 11 n/a n/a
BCDL 10.0 Code FRC2010ITP12007 (Matrix-M) Weight: 172 lb FT = 0%
LUMBER BRACING
TOP CHORD 2x4 SYP M 40 TOP CHORD Structural wood sheathing directly applied.
BOT CHORD 2x4 SYP M 40 `Except* BOT CHORD Structural wood sheathing directly applied or 4-0-15 oc bracing.
132: 2x4 SYP M 42 MiTek recommends that Stabilizers and required cross bracing
WEBS 2x4 SP No.3 be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size) 2=2230/0-8-0 (min. 0-3-0), 11=2274/0-B-0 (min. 0-3-1)
Max Horz 2=-80(LC 9)
Max Uplift2= 1177(LC 4), 11=-1235(LC 5)
Max Grav2=2552(LC 2), 11=2604(LC 2)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3= 5226/2371, 3-4=-5204/2398, 4-24=-6790/3241, 24-25=-6790/3241, 5-25=-6790/3241,
5-26=-6804/3253, 26-27=-6804/3253, 6-27=-6804/3253, 6-7=-6866/3320, 7-28=-6866/3320,
8-28=-6866/3320, 8-29=-6852/3308, 29-30= 6852/3308, 9-30=6852/3308, 9-10=-5335/2540,
10-11= 5353/2509
BOT CHORD 2-17= 2056/4722, 17-31=-2085/4817, 31-32=2085/4817, 16-32=-2085/4817,
16-33=-3421/7448,33-34=-3421/7448,15-34= 3421l7448,15-35=-3421/7448,
35-36=-3421 /7448, 14-36=-3421 /7448, 14-37=-2231 /4938, 37-38=-2231 /4938,
13-38= 2231/4938, 11-13=-2206/4839
WEBS 4-17=-29/498, 4-16=-1161/2344, 5-16=-568/484, 6-16=-798/377, 6-15=0/366,
6-14=-710/299, 8-14=-569/485, 9-14=-1086/2261, 9-13=-28/497
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope); cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) Plates checked for a plus or minus 0 degree rotation about its center.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1177 lb uplift at joint 2 and 1235 lb uplift at
joint 11.
9) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 95 lb down and 144 Ib up at 7-0-0,
97 lb down and 146 lb up at 9-0-12, 97 lb down and 146 lb up at 11-0-12, 97 lb down and 146 lb up at 13-0-12, 97 lb down and 146 lb
up at 15-0-12, 97 lb down and 146 lb up at 17-0-12, 97 lb down and 146 lb up at 18-11-4, 97 lb down and 146 lb up at 20-11-4, 97 lb
down and 146 lb up at 22-11-4, and 97 lb down and 146 lb up at 24-11-4, and 222 lb down and 280 lb up at 27-0-0 on top chord, and
314 lb down and 116 lb up at 7-0-0, 67 lb down at 9-0-12, 67 lb down at 11-0-12, 67 lb down at 13-0-12, 67 lb down at 15-0-12, 67 lb
down at 17-0-12, 67 lb down at 18-11-4, 67 lb down at 20-11-4, 67 lb down at 22-11-4, and 67 lb down at 24-11-4, and 314 lb down
Contan d 116 l papa 2 26-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
Job
I russ
I cuss I ype
ty
y
A013
973
55256
A01 G
�HIPTRUSS
1
1
Job Reference (optional)
Al ROOF TRUSSE5, FORI PIhRUL, FL 34945
nun: raou s Sep zi zu7 z rrim: t.sou s oep zr zu iz mi i eK n
NOTES
11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Regular: Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-4=-50, 4-9=-50, 9-12=-50, 18-21=-20
Concentrated Loads (lb)
Vert: 4=-79(F) 7=-81(F) 9=-154(F) 17=-272(F) 15=-41(F) 6=-81(F) 13=-272(F) 24= 81(F) 25=-81(F) 26=-81(F) 27=-81(F) 28=-81(F) 29= 81(F) 30= 81(F) 31=-41(F)
32=-41(F) 33=-41 (F) 34=-41 (F) 35=-41(F)36=41(F)37=-41(F)38=-41(F)
Job
I russ
I cuss I ype
y
A0131974
55256
A02
HIP TRUSS
2
1
Job Reference (optional)
Al ROOF TRUSSES, FORT PIERCE, FL 34946
2-4-10 ' 5-8-11
3x6 =
Run:7.350 s Sep 272012 Print:7.350 s Sep 27,
I D:Sf937)39GsZkfNbV2?PL3y8JmX
9-0-0 17-0-0 25-0-0
3-3-5 8-0-0 8-0-0
4x6 3x8 = 4x6 =
3x8 = 3x8 MT20H = 1.5x4 11 3x8 MT20H = 3x8 —
5-8-11
3x6 =
Scale=1:62.9
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0
BCDL 10.0
SPACING 2-0-0
Plates Increase 1.25
Lumber Increase 1.25
Rep Stress Incr YES
Code FRC2010/TPI2007
CSI
TC 0.94
BC 0.92
WB 0.47
(Matrix-M)
DEFL in (loc) I/defl Ud
Vert(LL) 0.45 12 >907 . 360
Vert(TL) -0.59 10-12 >688 240
Horz(TL) 0.18 8 n/a n/a
PLATES GRIP
MT20 244/190
MT20H 187/143
Weight:164 lb FT = 0%
LUMBER
BRACING
TOP CHORD 2x4 SYP M 38
TOP CHORD
Structural wood sheathing directly applied or 2-2-0 oc purlins.
BOT CHORD 2x4 SP No.2
BOT CHORD
Structural wood sheathing directly applied or 2-2-0 oc bracing.
WEBS 2x4 SP No.3
WEBS
T-Brace: 2 X 4 SYP No.3 - 5-14, 5-10
Fasten (2X) T and I braces to narrow edge of web with i Od (0.131 "x3")
nails, bin o.c.,with 3in minimum end distance.
Brace must cover 90 % of web length.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size) 2=1312/0-8-0 (min. 0-2-0), 8=1312/0-8-0 (min. 0-2-0)
Max Horz 2=-97(LC 13)
Max Uplift2= 601(LC 8), 8=-601(LC 9)
Max Grav 2=1 506(LC 2), 8=1506(LC 2)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3094/2230, 3-4=2842/2042, 4-5=-2644/1963, 5-6=-2644/1962, 6-7=-2841/2042,
7-8=-3094/2229
BOT CHORD 2-14=-1820/2772, 13-14=-2150/3372, 12-13=-2150/3372, 11-12_ 2150/3372,
10-11=-2150/3372, 8-1 0=-1 842/2782
WEBS 3-14=-284/360, 4-14=395/703, 5-14=-907/668, 5-12=0/305, 5-10=-907/668, 6-10=-394l7021
7-10=-283/359
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=5.Opsf; BCDL=S.Opsf; h=25ft; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) Plates checked for a plus or minus 0 degree rotation about its center.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live.loads.
7) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 601 lb uplift at joint 2 and 601 lb uplift at joint
8.
9) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
10) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
Job
I russ
I russ I ype
y
A01 3
975
55256
A03
HIP TRUSS
2
1
Job Reference (optional)
A i nuur i nua mm , run i narn.m, rL zgvga
4x8 =
nun: iaou s oeu ci cu,c cone i.u�u a oeu a cu i c mi i
6-0-0 6-0-0
1.5x4 11 48 =
3x6 __ 1.5x4 11 3x4 3x8 = 3x4 = 1.5x4 11 3x6 =
3x4 = 3x4 =
cu,c reye�
Scale =1
LOADING (psf)
SPACING
2-0-0
CSI
DEFL in
(loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plates Increase
1.25
TC 0.96
Vert(LL) . 0.39
13 >999 360
MT20 244/190
TCDL 10.0
Lumber Increase
1.25
BC 0.87
Vert(TL) -0.47
11-13 >861 240
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.48
Horz(TL) 0.16
8 n/a n/a
BCDL 10.0
Code FRC201 0/TP 12007
(Matrix-M)
Weight:176 lb FT = 0%
LUMBER
BRACING
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied.
BOT CHORD 2x4 SP No.2
BOT CHORD
Structural wood sheathing directly applied or 3-11-6 oc bracing.
WEBS 2x4 SP No.3
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
REACTIONS (lb/size) 2=1312/0-8-0 (min. 0-2-0), 8=1312/0-8-0 (min. 0-2-0)
Max Horz 2=-113(LC 13)
Max Uplift2=-572(LC 8), 8=-572(LC 9)
Max Grav 2=1 506(LC 2), 8=1506(LC 2)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3226/2267, 3-4=-2690/1944, 4-5=-2820/2138, 5-6=-2820/2138, 6-7=-2690/1944,
7-8=-3225/2265
BOT CHORD 2-16=-1869/2905, 15-16=-1869/2905, 14-15=-1404/2375, 13-14=-1404/2375,
12-13=-1409/2378, 11-12= 1409/2378, 10-11 =-1 898/2918, 8-10==1898/2918
WEBS 3-15= 591/530, 4-15=-149/379, 4-13=-322/531, 5-13=-443/460, 6-13=-322/531,
6-11=-149/379, 7-11=-591/529
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=5.Opsf; BCDL=S.Opsf; h=25ft; Cat. 11; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) Plates checked for a plus or minus 0 degree rotation about its center.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) . This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 572 lb uplift at joint 2 and 572 lb uplift at joint
8.
8) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
o
russ
russ ype
y
A0131976
55256
A04
HIP TRUSS 2
1
Job Reference o tional
All ROOF TRUSSES, FORT PIERCE, FL 34946 Run: 7.350 s Sep 27 2012 Print: 7.350 s Sep 27 2012 MTek Industries, Inc. Mon Dec 10 09:00:53 2012 Page 1
ID:Sf937139GsZkfNbV2?PL3yBJmX-ZwBVB4brlgNAomW577hjmZi3xKjaad4FggrnaKyAQre
2-410 7-8-7 13-0-0 21-0-0 26-3-9 34-0-0 36-NO
2-4-10 7-8-7 5-3-9 B-0-0 5-3-9 7-8-7 2-4-10
5.00 12
48 =
4x6 =
Scale: 3/16"=1'
3x6 =
1.5x4 11 3x8 MT20H = 3x8 = 1.5x4 11 3x6 =
3x4 = 3x8 MT20H=
26.3-9
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0
BCDL 10.0
SPACING 2-0-0
Plates Increase 1.25
Lumber Increase 1.25
Rep Stress Incr YES
Code FRC2010/TPI2007
CSI
TC 0.91
BC 0.77
WB 0.54
(Matrix-M)
DEFL in (loc) I/defl Ud
Vert(LL) 0.31 12 >999 360
Vert(TL) -0.48 11-12 >843 240
Horz(TL) 0.15 7 n/a n/a
PLATES GRIP
MT20 244/190
MT20H 187/143
Weight:168 Ito FT = 0 %
LUMBER
BRACING
TOP CHORD 2x4 SP No.2 `Except*
TOP CHORD
Structural wood sheathing directly applied.
T3: 2x4 SYP M 40, T1: 2x4 SYP M 38
BOT CHORD
Structural wood sheathing directly applied or 4-4-12 oc bracing.
BOT CHORD 2x4 SP No.2
WEBS
T-Brace: 2 X 4 SYP No.3 - 4-11
WEBS 2x4 SP No.3
Fasten (2X) T and I braces to narrow edge of web with 10d (0.131 "x3")
nails, bin o.c.,with 3in minimum end distance.
Brace must cover 90% of web length.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size) 2=1352/0-8-0 (min. 0-2-1), 7=1341/0-8-0 (min. 0-2-1)
Max Horz 2=-130(LC 13)
Max Uplift2=-542(LC 8), 7— 542(LC 9)
Max Grav2=1507(LC 2), 7=1506(LC 2)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=3136/2135, 3-4=-2582/1840, 4-5=-2342/1782, 5-6— 2551/1840, 6-7=-3110/2134
BOT CHORD 2-14= 1706/2793, 13-14=-1708/2790, 12-13=-1708/2790, 12-21= 1230/2261,
11-21=-1230/2261, 10-11=-1722/2773, 9-10=-1722/2773, 7-9=-1720/2775
WEBS 3-12= 644/583, 4-12=-240/545, 5-11=-239/512, 6-11=-648/583
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=S.Opsf; BCDL=S.Opsf; h=25ft; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) Plates checked for a plus or minus 0 degree rotation about its center.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 10.Opsf.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 542 lb uplift at joint 2 and 542 Ito uplift at joint
7.
9) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
10) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
Job
I russ
Iruss ype
y
1
TI.
' Ao13 sn
55256
ADS
HIP TRUSS
1
Job Reference (optional)
Al HOOF I BUSSES, FORT PIEROE, FL 34946
dI
0
5.00 F12
46 = 46 =
12
2-4-10 '
Scale: 3/1
3x6 =
1.5x4 11 3x8 Mf20H= 3x4 = 3x4 = 3x8 Mf20H= 1.5x4 11 3x6 =
34-0-0
m
LOADING (psf)
SPACING
2-0-0
CSI
DEFL in
(loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plates Increase
1.25
TC 0.94
Vert(LL)-0.3811-13
>999 360
MT20 244/190
TCDL 10.0
Lumber Increase
1.25
BC 0.90
Vert(TL) -0.70
11-13 >587 240
MT20H 187/143
BCLL 0.0
Rep Stress Incr
YES
WB 0.43
HOrz(TL) 0.16
9 n/a n/a
BCDL 10.0
Code FRC2010fTP12007
(Matrix-M)
Weight: 163 lb FT = 0%
LUMBER
BRACING
TOP CHORD 2x4 SYP M 38
`Except`
TOP CHORD
Structural wood sheathing directly applied or 2-2-0 oc purlins.
T3: 2x4 SP No.2
BOT CHORD
Structural wood sheathing directly applied or 2-2-0 oc bracing.
BOT CHORD 2x4 SP No.2
WEBS
T-Brace: 2 X 4 SYP No.3 - 3-14, 8-13 . j
WEBS 2x4 SP No.3
Fasten (2X) T and I braces to narrow edge of web with 10d (0.131 x3")
nails, 6in o.c.,with 3in minimum end distance.
Brace must cover 90% of web length.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation auide.
REACTIONS (lb/size) 2=1368/0-8-0 (min. 0-2-2), 9=1368/0-8-0 (min. 0-2-2)
Max Horz2=-147(LC 13)
Max Uplift2=-561(LC 12), 9=-561(LC 13)
Max Grav2=1506(LC 2), 9=1506(LC 2)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3277/2228, 3-4=-2448/1704, 4-5=-2370/1730, 5-6=-2230/1708, 6-7=-2370/1729,
7-8=-2448/1704, 8-9= 3277/2227
BOT CHORD 2-16— 1805/2934, 15-16=-1805/2934, 14-15= 1805/2934, 13-14=-1084/2102,
12-13— 1819/2940, 11-12=-1819/2940, 9-11=-1819/2940
WEBS 3-16=0/296, 3-14=-928/810, 5-14= 274/542, 6.13=-274/542, 8-13=-928/809, 8-11=0/296
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) Plates checked for a plus or minus 0 degree rotation about its center.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0.0 wide will fit
between the bottom chord and any other members, with BCDL = 10.Opsf.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 561 lb uplift at joint 2 and 561 lb uplift at joint
9.
9) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
10) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
Job
I russ
I russ Type
Qty
Ply
A0131978
55256
A06
COMMON TRUSS
12
1
Job Reference (optional)
Al ROOF TRUSSES, FORT PIERCE, FL 34946 Run: 7.350 s Sep 27 2012 Print: 7.350 s Sep 27 2012 MiTek Industries, Inc. Mon Dec 10 09:00:54 2012 Pagel
ID:Sf937j39GsZkfNbV2?PL3yBJmX-161tMQbT3_V1 Qw510gCyJmEEgkl mJ_tPuKaK7myAQrd
2 4-10 6-4-0 11-6-10 17 11 0 22-5-6 27-8-0 34-0-0 36 4-10
2-4-10 6-4-0 5-2-9 5-5-6 5-5-6 5-2-9 6-4-0 2-4-10
Scale=1:61.9
4x4 =
5.00 FIT
110
3x4 = 3x4 = 3x8 _ 3x4 = 3x4 = 3x6 =
3x6 =
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0
BCDL 10.0
SPACING 2-0-0
Plates Increase 1.25
Lumber Increase 1.25
Rep Stress Incr YES
Code FRC2010fTP12007
CSI
TC 0.90
BC 0.83
WB 0.95
(Matrix-M)
DEFL in (loc) I/defl Ud
Vert(LL) 0.36 14-16 >999 360
Vert(TL) -0.49 12-14 >839 240
Horz(TL) 0.15 10 n/a n/a
PLATES GRIP
MT20 244/190
MT20H 187/143
Weight: 170 lb FT = 0
LUMBER
BRACING
TOP CHORD 2x4 SP No.2 *Except*
TOP CHORD
Structural wood sheathing directly applied or 2-2-0 oc purlins.
Tl : 2x4 SYP M 38
BOT CHORD
Structural wood sheathing directly applied or 4-0-11 oc bracing.
BOT CHORD 2x4 SP No.2
MiTek recommends that Stabilizers and required cross bracing
WEBS 2x4 SP No.3
be installed during truss erection, in accordance with Stabilizer
Installation quide.
REACTIONS (lb/size) 2=1312/0-8-0 (min. 0-2-1), 1 0=1 312/0-8-0 (min. 0-2-1)
Max Horz 2=-164(LC 13)
Max Uplift2=-578(LC 12), 10=-578(LC 13)
Max Grav2=1506(LC 2), 10=1506(LC 2)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3197/2342, 3-4_ 2944/2175, 4-5= 2896/2186, 5-6=-2115/1676, 6-7= 2115/1676,
7-8— 2896/2186, 8-9=-2944/2175, 9-10=-3196/2342
BOT CHORD 2-16=-1925/2868, 15-16=-1476/2364, 14-15=-1476/2364, 13-14— 1480/2366,
12-13=-1480/2366, 10-12=-1942/2876
WEBS 6-14=-898/1219, 7-14=-787/731, 7-12=-271/488, 9-12=-385/467, 5-14=-787l731,
5-16=-272/488, 3-16=-385/467
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.33 plate grip DOL=1.33
3) All plates are MT20 plates unless otherwise indicated.
4) Plate(s) at joint(s) 4, 6, 8, 2, 14, 7, 12, 9, 5, 16, 3 and 10 checked for a plus or minus 0 degree rotation about its center.
5) Plate(s) at joint(s) 15 and 13 checked for a plus or minus 5 degree rotation about its center.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 578 lb uplift at joint 2 and 578 lb uplift at joint
10.
9) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
Job
I russ
I russ Type
y
' A011979
65256
A07G
HIP TRUSS
1
1
Job Reference (optional)
2-4-10 3-9-14
5.00 F12
nurr.ID:Sf9;
15-0-0 19-0-9
3-11-2 4-0-9
4x4 = 3x8 = 4x6 = 5x6 = 3x8 =
4 27 5 .28 6 29 7 30 8- 31
I G =1 eK IMUSU12S. Inc. mon uec i u
4x4 =
9
1.5x4
3
2
!'a
1.5x4
10
11
20 32 19 18 33 17 34 16 35 15 14 36 13
3x8 = 4x6 II 4x8 = 1.5x4 II 3x8 =
3x4 = 3x4 = 3x4 =
1.5x4 11 3x4 =
27-0-0 1 30-2-2
k0d&a
3 zulz rage i
r KufDy Qrc
4-10
I�
Srale = :62.9
i
co
7
LOADING (psf)
SPACING
2-0-0
CSI
DEFL
in (loc) I/dell Ud
PLATES GRIP
TCLL 20.0
Plates Increase
1.25
TC 0.77
Vert(LL)
0.10 13-14 >999 360
MT20 244/190
TCDL 10.0
Lumber Increase
1.25
BC 0.65
Vert(TL)
-0.17 13-14 >999 240
BCLL 0.0 '
Rep Stress Incr
NO
WB 1.00
Horz(TL)
0.04 11 n/a n/a
BCDL 10.0
Code FRC201 O/TP12007
(Matrix-M)
Weight:178 lb FT = 0
LUMBER
BRACING
TOP CHORD 2x4 SP No.2
TOP CHORD Structural wood sheathing directly applied or 3-10-9 oc purlins.
BOT CHORD 2x4 SP No.2
BOT CHORD Structural wood sheathing directly applied or 4-4-5 oc bracing.
WEBS 2x4 SP No.3
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
REACTIONS (lb/size) 2=635/0-8-0 (min. 0-1-8), 17=2766/0-8-0 (min. 0-3-12), 11=1013/0-4-8 (min. 0-1-8)
Max Horz 2- 80(LC 9)
Max Uplift2=-339(LC 8), 17=-1517(LC 4), 11=-575(LC 9)
Max Grav2=748(LC 21), 17=3160(LC 2), 11=1175(LC 22)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-998/467, 3-4� 792/360, 4-27=-698/356, 5-27=-698/356, 5-28=-677/1662,
6-28=-677/1662, 6-29= 299/244, 7-29=-299/244, 7-30- 292/238, 8-30=-292/238,
8-31= 1695/905, 9-31 =-1 695/905, 9-1 0=-1 845/947, 10-11=-2029/1039
BOT CHORD 2-20= 402/881, 17-34=-1662/837, 16-34=-1662/837, 16-35=-604/1400, 15-35=-604/1400,
14-15=-604/1400, 14-36=-604/1400, 13-36=-604/1400, 11 -1 3=-845/1822
WEBS 6-17=-1841/1033, 6-16=-1123/2356, 7-16= 406/348, 8-16=-1411/666, 8-14=0/273,
8-13=-188/390, 9-13=0/374, 5-19=0/251, 5-20= 420/979, 5-17=-1927/872
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASIDE 7-10; VuIt=160mph (3-second gust) Vasd=124mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope); cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) Plates checked for a plus or minus 0 degree rotation about its center.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 339 lb uplift at joint 2, 1517 lb uplift at joint
17 and 575 lb uplift at joint 11.
8) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 95 lb down and 144 lb up at 7-0-0,
95 lb down and 144 lb up at 9-0-12, 95 lb down and 144 lb up at 11-0-12, 95 Ito down and 144 lb up at 13-0-12, 95 lb down and 144 lb
up at 15-0-12, 95 lb down and 144 lb up at 17-0-0, 95 lb down and 144 lb up at 18-11-4, 95 lb down and 144 lb up at 20-11-4, 95 lb
down and 144 lb up at 22-11-4, and 95 lb down and 144 lb up at 24-11-4, and 182 lb down and 280 lb up at 27-0-0 on top chord, and
314 lb down and 116 lb up at 7-0-0, 65 lb down at 9-0-12, 65 lb down at 11-0-12, 65 lb down at 13-0-12, 65 lb down at 17-0-0, 65 Ito
down at 18-11-4, 65 lb down at 20-11-4, 65 lb down at 22-11-4, and 65 lb down at 24-11-4, and 314 lb down and 116 lb up at 26-11-4
on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
Continued on page 2
Job
I russ
Truss I ype
Ply
A0131979
55256
A07G
HIP TRUSS 17
1
Job Reference (optional)
MI ri ur IRUJJCA, FORT rirriur, rLJ4MO
Nun: 7.35U s Sep 27 2012 Prin1: 7.350 s Sep 27 2012 MI I eK Intlustrles, Inc. Mon Dec 10 09:OOS5 2012 Page 2
ID:Sf93T39GsZkfNbV2?PL: yBJmX-VJJFZmc5gIdu24gUaYBs_nRgBQv2QNY7_KufDyAQrc
LOAD CASE(S) Standard
1) Regular: Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-4=-50, 4-9= 50, 9-12=-50, 21-24= 20
Concentrated Loads (lb)
Vert: 4=-79(B) 9=-154(B) 20=-272(B) 6=-79(B) 7= 79(B) 16= 37(B) 14=-37(B) 8=-79(B) 13=-272(B) 19=-37(B) 5=-79(B) 27=-79(B) 28=-79(B) 29=-79(B) 30=-79(B)
31=-79(B) 32=-37(B) 33=-37(B) 34=-37(B) 35=-37(B) 36=-37(B)
Job
I russ
I cuss I ype
Qty
y
A01 1960
55256
B01 G
Hip Truss
1
1
Job Reference (optional)
Al MUUr- I MUJbtb, rUM I r-ItMUt, M 34e4b Mun: /.3bu s be, 212u12 vrin[: /.3bU 5 bep 2/ zu12 MI I eK Inausvle$, Ina. Mon Ueb 10 os:uu:bb 2012 F
ID:Sf937139GsZkfNbV2?PL3yB1mX-VJJFZmcSgldu24gUarBs_nTOBRA2cjY7_KufDt
3-9-14 7-0-0 8-0-0 11-2-2 15-0-0
3-9-14 3-2-2 .1-0-0 3-2-2 3-9-14
44 = 4x4 =
3x4 = 1.5x4 11 1.5x4 11
Scale =
3x4 =
3-9-14
3-2-2
1-0-0
3-2-2 3-9-14
LOADING (psf)
SPACING 2-0-0
CSI
DEFL in
(loc) I/deft Ud
PLATES GRIP
TCLL 20.0
Plates Increase 1.25
TC 0.66
Vert(LL) 0.10
6-9 >999 360
MT20 244/190
TCDL 10.0
Lumber Increase 1.25
BC 0.63
Vert(TL) -0.19
6-9 >967 240
BCLL 0.0
Rep Stress Incr NO
WB 0.21
Horz(TL) 0.05
4 n/a n/a
BCDL 10.0
Code FRC2010/TPI2007
(Matrix-M)
Weight: 55 lb FT = 0
LUMBER
BRACING
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 3-4-2 oc purlins.
BOT CHORD 2x4 SP No.2
BOT CHORD
Structural wood sheathing directly applied or 6-5-10 oc bracing.
WEBS 2x4 SP No.3
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size) 1=917/0-4-8 (min. 0-1-8), 4=911/0-4-8 (min. 0-1-8)
Max Horz 1=59(LC 8)
Max Upliftl=-499(LC 8), 4=-487(LC 9)
Max Grav1=1046(LC 2), 4=1038(LC 2)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2= 1948/928, 2-3— 1739/890, 3-4=-1944/922
BOT CHORD 1-6=-1052/1791, 5-6= 788/1739, 4-5=-943/1751
WEBS 2-6=-73/443, 3-5=-171/507
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; VuIt=160mph (3-second gust) Vasd=124mph; TCDL=S.Opsf; BCDL=S.Opsf; h=25ft; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope); cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) Plates checked for a plus or minus 0 degree rotation about its center.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 499 lb uplift at joint 1 and 487 lb uplift at joint
4.
8) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 222 lb down and 303 lb up at 7-0-0,
and 95 lb down and 144 lb up at 8-0-0 on top chord, and 314 lb down and 116 lb up at 7-0-0, and 314 lb down and 116 lb up at 7-11-4
on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Regular: Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-2=-50, 2-3=-50, 3-4=-50, 7-10— 20
Concentrated Loads (lb)
Vert: 2=-154(F) 3=-79(F) 6= 272(F) 5=-272(F)
o
toss
tossype�Qty
ply
A0131981
55256
CA
JACK -OPEN TRUSS 12
1
Job Reference (optional)
Al ROOF TRUSSES, FORT PIERCE, FL 34946 Run: 7.350 s Sep 27 2012 Print: 7.350 s Sep 27 2012 MiTek Industries, Inc. Mon Dec 10 09:00:56 2012 Page 1
ID:Sf937j39GsZkfNbV2? PL3yBJmX-zVsdm6djbbllf EFg8FEQOBKZMXtnn6BiMe3RBfyAQrb
-2-4-10 i 0-11-11
2-4-10 0-11-11
Scale =1:8.8
Plate Offsets (X,Y): [2:0-0-10,Edge]
LOADING (psf)
SPACING 2-0-0
CSI
DEFL in
(loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plates Increase 1.25
TC 0.96
Vert(LL) 0.00
7 >999 360
MT20 244/190
TCDL 10.0
Lumber Increase 1.25
BC 0.16
Vert(TL) 0.00
7 >999 240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.00
Horz(TL) 0.00
2 n/a n/a
BCDL 10.0
Code FRC2010/TPI2007
(Matrix-M)
Weight: 7 lb FT = 0
LUMBER
BRACING
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied.
BOT CHORD 2x4 SP No.2
BOT CHORD
Structural wood sheathing directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size) 2=285/0-8-0 (min. 0-1-8), 3=-35/Mechanical, 6=-60/Mechanical
Max Horz 2=84(LC 8)
Max Uplift2=-31 1 (LC 8), 3=-43(LC 2), 6=-74(LC 2)
Max Grav2=341(LC 2), 3=57(LC 8), 6=98(LC 8)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-462/245
BOT CHORD 2-6— 266/505
NOTES
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp C; Enclq GCpi=0.18;
MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.33 plate grip DOL=1.33
2) Plates checked for a plus or minus 0 degree rotation about its center.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 311 lb uplift at joint 2, 43 lb uplift at joint 3
and 74 lb uplift at joint 6.
7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
Job
I russ
I russ Type
Uty
Fly
j
' A01
1982
55256
CJ3
JACK -OPEN TRUSS
12
1
I
.
Job Reference (optional)
N 1 nuur I nuao.o, run I -nu., rL d vtl u nun: /.aoIu :LLu - MI tlInuu5Ln. Inc.
3Lrl
DGkfNbVT;mX-Rho?_SeLLvtbFOps-2-4-10 2-11-11
2-4-10 2-11-11
0
rcu1c r 9 1
3Hp?j51
Ora
Scale = :12.9
J -
LOADING (psf)
SPACING 2-0-0
CSI
DEFL in (loc) Udell Ud
PLATES GRIP
TCLL 20.0
Plates Increase 1.25
TC 0.96
Vert(LL) -0.01 4-7 >999 360
MT20 244/190
TCDL 10.0
Lumber Increase 1.25
BC 0.19
Vert(TL) -0.01 4-7 >999 240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.00
Horz(TL) 0.00 2 n/a n/a
BCDL 10.0
Code FRC2010/TP12007
(Matrix-M)
Weight: 13 lb FT = 0%
LUMBER BRACING
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied.
BOT CHORD 2x4 SP No.2 BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
REACTIONS (lb/size) 3=44/Mechanical, 2=264/0-4-8 (min. 0-1-8), 4=18/Mechanical
Max Horz2=116(LC 8)
Max Uplift3=-47(LC 12), 2=-194(LC 8)
Max Grav3=52(LC 2), 2=310(LC 2), 4=41(LC 3)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-704/270
BOT CHORD 2-4=-266/699
NOTES
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=S.Opsf; BCDL=S.Opsf; h=25ft; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.33 plate grip DOL=1.33
2) Plates checked for a plus or minus 0 degree rotation about its center.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 47 lb uplift at joint 3 and 194 Ito uplift at joint
2.
7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
Job
1 russ
russ I ype
ty
y
,
A0131983
55256
CJS
JACK -OPEN TRUSS
12
1
Job Reference (optional)
Al ROOF TRUSSES, FORT PIERCE, FL 34946 Run: 7.350 s Sep 27 2012 Print: 7.350 s 9egP27 2012 Mi I ek Industries, Inc. Mon uec 10 09:00:57 2012 Page 1
ID:Sf937j39GsZkfNbV2?PL3yBJmX-RhQ?_SeLLvIbHOpsiylfxPsj6xCRWZQrbHp?jSyAQra
2-4-10 4-11-11
2-4-10
Scale=1:16.9
LOADING (psf)
SPACING
2-0-0
CSI
DEFL in
([cc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plates Increase
1.25
TC 0.96
Vert(LL) -0.02
4-7 >999 360
MT20 244/190
TCDL 10.0
Lumber Increase
1.25
BC 0.19
Vert(TL) -0.05
4-7 >999 240
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.00
Horz(TL) 0.00
2 n/a n/a
BCDL 10.0
Code FRC2010/TPI2007
(Matrix-M)
Weight: 19 lb FT = 0
LUMBER
BRACING
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied.
BOT CHORD 2x4 SP No.2
BOT CHORD
Structural wood sheathing directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size) 3=89/Mechanical, 2=337/0-4-8 (min. 0-1-8), 4=40/Mechanical
Max Horz 2=157(LC 12)
Max Uplift3=-93(LC 12), 2— 195(LC 8)
Max Grav3=106(LC 2), 2=393(LC 2), 4=74(LC 3)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3= 718/0
BOT CHORD 2-4=-126/926
NOTES
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=S.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.33 plate grip DOL=1.33
2) Plates checked for a plus or minus 0 degree rotation about its center.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 93 lb uplift at joint 3 and 195 lb uplift at joint
2.
7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
Job
I russ
I russ Type
Qty
Ply
A01
H
55256
HC5
RAFTER TRUSS
20
1
Job Reference o tional
f1Yl G U GCK
IDIn1EI4nN4krFMR5VCllXl.8/1JW4zI20�Jvo/OBVoez6IDI
2-8-9 295
2-8-9 0- - 2
1
uec I U Ue:UU: u GU 14 race I
Scale =
v
0
1:8.2
-0 0 12
2-9-5
0- - 2
2-9-5
LOADING (psf)
SPACING 2-0-0
CSI
DEFL in
(loc) I/dell Ud
PLATES GRIP
TCLL 20.0
Plates Increase 1.25
TC 0.13
Vert(LL) -0.01
1-2 >999 360
TCDL 7.0
Lumber Increase 1.25
BC 0.00
Vert(TL) -0.01
1-2 >999 240
BCLL 0.0 '
Rep Stress Incr YES
WB, 0.00
Horz(TL) -0.00
2 n/a n/a
BCDL 10.0
Code FRC2010/TP12007
(Matrix-M)
Wind(LL) 0.01
1-2 >999 240
Weight: 4lb FT=20%
LUMBER
BRACING
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 2-9-5 oc purlins.
BOT CHORD
Rigid ceiling directly applied.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation Guide.
REACTIONS (lb/size) 1=57/Mechanical, 2=59/Mechanical
Max Horz 1=31(LC 12)
Max Upliftl= 34(LC 12), 2=-47(LC 12)
Max Grav 1=70(LC 2), 2=72(LC 2)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Wind: ASCE 7-10; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=S.Opsf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. 11;
Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces
& MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
2) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
3) Refer to girder(s) for truss to truss connections.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 34 lb uplift at joint 1 and 47 lb uplift at joint 2.
5) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
Job
I russ
russ ype
y
A0131985
55256
HJ7
Diagonal Hip Girder
6
1
Job Reference (optional)
Al HWr I HUSStS, P-UK I PlhHUL, rL 94s45 Hun: /.JDU s Se z/ zUlz vrin[: /.3DU s Se z/ zul z ml I eK Inausuies, Inc. noon uec 1 u Uy:UU:Dtf ZUl z rage 1
ID:Sf937j39 sZkfNbV2?PL3yBJm-Vl_OBoez6DOSvYO3FgGuTcPwDLTVFx8?pxYYGYYAQrz
-3-5-14 5-2-9 _ 9-9-12_ _ _ _ _ 9-t,p-1
3-5-14 5-2-9 4-7-4 0- -4
Scale=1:24.3
.1�
5-2-9
- ' 4-7-2 0-0-6
LOADING (psf)
SPACING
2-0-0
CSI
DEFL in
(Ioc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plates Increase
1.25
TC 0.88
Vert(LL) 0.04
6-7 >999 360
MT20 244/190
TCDL 10.0
Lumber Increase
1.25
BC 0.53
Vert(TL) -0.11
6-7 >999 240
BCLL 0.0
Rep Stress Incr
NO
WB 0.35
Horz(TL) 0.01
5 n/a n/a
BCDL 10.0
Code FRC201 O!f P12007
(Matrix-M)
Weight: 44 lb FT = 0
LUMBER
BRACING
TOP CHORD 2x4 SYP M 38
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP No.2
BOT CHORD
Structural wood sheathing directly applied or 9-8-7 oc bracing.
WEBS 2x4 SP No.3
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size) 4=124/Mechanical, 2=444/0-10-15 (min. 0-1-8), 5=258/Mechanical
Max Horz 2=243(LC 4)
Max Uplift4=-127(LC 4), 2=-360(LC 4), 5=-103(LC 8)
Max Grav4=147(LC 2), 2=534(LC 2), 5=291(LC 3)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-11=-1113/570, 11-12=-729/250, 3-12=-676/260
BOT CHORD 2-14=-585/1044, 14-15=-355/672, 7-15=-355/672, 7-16=-355/672, 6-16=-355/672
WEBS 3-7=0/255, 3-6=-715/377
NOTES
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=S.Opsf; BCDL=S.Opsf; h=25ft; Cat. 11; Exp C; Encl., GCpi=0.18;
MWFRS (envelope); cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) Plates checked for a plus or minus 0 degree rotation about its center.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 127 lb uplift at joint 4, 360 lb uplift at joint 2
and 103 lb uplift at joint 5.
7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 50 lb down and 59 lb up at 1-4-9, 50
lb down and 59 lb up at 1-4-9, 3 lb down and 55 lb up at 4-2-8, 3 lb down and 55 lb up at 4-2-8, and 46 lb down and 101 lb up at 7-0-7,
and 46 lb down and 101 lb up at 7-0-7 on top chord, and 0 lb down and 48 lb up at 1-4-9, 0 lb down and 48 lb up at 1-4-9, 1 lb down
and 10 lb up at 4-2-8, 1 lb down and 10 lb up at 4-2-8, and 34 lb down and 1 lb up at 7-0-7, and 34 lb down and 1 lb up at 7-0-7 on
bottom chord. The design/selection of such connection device(s) is the responsibility of others.
9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Regular: Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-4=-50, 5-8=-20
Concentrated Loads (lb)
Vert:,11=60(F=30, B=30) 12=12(F=6, B=6) 13=-77(F=-39, 8= 39) 14=77(F=39, B=39) 15=4(F=2, B=2) 16=-40(F=-20, B=-20)
Job
russ
I cuss Type
Qty
Ply
' A01
1986
55256
J7
JACK -OPEN TRUSS
15
1
Job Reference (optional)
Al ROOF TRUSSES, FORT PIERCE, FL 34946 Run: 7.350 s Sep 27 2012 Print: 7.350 s Sep 27 2012 Mi fek Industries, Inc. Mon Dec 10 09:
I D:Sf937139GsZkfNbV2?PL3_yBJmX-N4YmP8fbtWeJ WhzFpNo70gy3?lm_
-2-4-10 7-0-0
2-4-10 7-0-0
Scale =
0
6
N
7-0 D
I
7-0-0
Plate Offsets (X,Y): [2:0-0-6,Edge)
LOADING (psf)
SPACING 2-0-0
CSI
DEFL in
(loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plates Increase 1.25
TC 1.00
Vert(LL) 0.09
4-7 >937 360
MT20 244/190
TCDL 10.0
Lumber Increase 1.25
BC 0.39
Vert(TL) -0.16
4-7 >534 240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.00
Horz(TL) 0.01
2 n/a n/a
BCDL 10.0
Code FRC2010fTP12007
(Matrix-M)
Weight: 26 lb FT = 0%
LUMBER
BRACING
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied.
BOT CHORD 2x4 SP No.2
BOT CHORD
Structural wood sheathing directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size) 3=129/Mechanical, 2=421/0-4-8 (min. 0-1-8),
4=58/Mechanical
Max Horz 2=203(LC 12)
Max Uplift3= 136(LC 12), 2=-209(LC 8)
Max Grav3=154(LC 2), 2=489(LC 2), 4=105(LC 3)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3= 1290/595
BOT CHORD 2-4=-1097/1686
NOTES
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=S.Opsf; BCDL=S.Opsf; h=25ft; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.33 plate grip DOL=1.33
2) Plates checked for a plus or minus 0 degree rotation about its center.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 136 lb uplift at joint 3 and 209 lb uplift at joint
2.
7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
o
ss
cuss ype
City
y
A0131967
55256
�J:
Jack -Open Truss
9
1
Job Reference o tional
Al ROOF TRUSSES, FORT PIERCE, FL 34946
3x6 =
Run: 7.350 s Sep 27 2012 Print: 7.350 s Sep 27 2012 MiTek Industries, Inc. Mon Dec 10 09:00:59 2012 Page 1
ID:Sf937139GsZkfNbV2?PL3yBJmX-N4YmP8fbtW8J WhzFpNo70gy3Klrl _Tw82bi5oyAQrY
7-0-0
.7-0-0
_o
6
N
Scale=1:19.4
7-0-0
Plate Offsets (X,Y): fl:0-0-2,0-0-01
LOADING (psf)
SPACING 2-0-0
CSI
DEFL in
(loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plates Increase 1.25
TC 0.98
Vert(LL) 0.12
3-6 >679 360
MT20 244/190
TCDL 10.0
Lumber Increase 1.25
BC 0.45
Vert(TL) -0.17
3-6 >501 240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.00
Horz(TL) -0.01
1 n/a n/a
BCDL 10.0
Code FRC2010/TP12007
(Matrix-M)
Weight: 22 lb FT = 0
LUMBER
BRACING
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied.
BOT CHORD 2x4 SP No.2
BOT CHORD
Structural wood sheathing directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size) 1=293/0-8-0 (min. 0-1-8), 2=1 31 /Mechanical, 3=61/Mechanical
Max Horz 1=159(LC 12)
Max Upliftl=-120(LC 12), 2=-138(LC 12)
Max Gravl=335(LC 2), 2=157(LC 2), 3=107(LC 3)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-1368/1384
BOT CHORD 1-3=-2035/1816
NOTES
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. 11; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.33 plate grip DOL=1.33
2) Plates checked for a plus or minus 0 degree rotation about its center. .
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 120 lb uplift at joint 1 and 138 lb uplift at joint
2.
7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
Job
I russ
I russ Type
Q tyPly
1
A01
' •3
9g0
55256
V4
Valley Truss
1 1
Job Reference o tional
...,�... ..... �.. ,"
ID:Sf937j39 sZkfNbV2?PL3yBJmX-rG68cUgEegGABrYRN5JMZ1US79G?jwAHHF1fKOy
y� ,
QrX
2-0-0
4-0-0
2-0-0
2-0-0
3x4 =
Scale =1:7.3
5.00 F12
2
3
Ci
1
a
c
131
a
ro
0
6
2x4
2x4
0- -10
4-0-0
0- - 0
3-11-6
Plate Offsets X, 2:0-2-0,Ed e
LOADING (psf)
SPACING 2-0-0
CSI
DEFL in
(loc) I/defl L/d
PLATES GRIP
TCLL 20.0
Plates Increase 1.25
TC 0.08
Vert(LL) n/a
n/a 999
MT20 244/190
TCDL 10.0
Lumber Increase 1.25
BC 0.08
Vert(TL) n/a
n/a 999
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(TL) -0.00
3 n/a n/a
BCDL 10.0
Code FRC2010/TP12007
(Matrix)
Weight: 10 lb FT = 0%
LUMBER
BRACING
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 4-0-0 oc purlins.
BOT CHORD 2x4 SP No.2
BOT CHORD
Structural wood sheathing directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
REACTIONS (lb/size) 1=87/3-10-13 (min. 0-1-8), 3=87/3-10-13 (min. 0-1-8)
Max Horz 1— 11(LC 13)
Max Upliftl=-36(LC 12), 3=-36(LC 13)
Max Grav 1=100(LC 2), 3=100(LC 2)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.33 plate grip DOL=1.33
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 36 lb uplift at joint 1 and 36 lb uplift at joint 3.
8) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
l
oruss
cuss ype
y
JV18
A013
55256
Valley Truss
1
1
�91
Job Reference o tional
o
11 n
0
2x4
2
nuiiID:Sf937'39GsZkfNbV2?PL3 u B 1mX-rG68cU Ee GA8rYRN5JMZ1 UNI99L'wAHHFifKQrA6rX
1 9 4 1 Y
3x4 =
2x4
Scale=1:14.5
•o
0
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0 '
BCDL 10.0
SPACING 2-0-0
Plates Increase 1.25
Lumber Increase 1.25
Rep Stress Incr YES
Code FRC2010/TPI2007
CSI
TC 0.43
BC 0.57
WB 0.00
(Matrix)
DEFL in
Vert(LL) n/a
Vert(TL) n/a.
Horz(TL) -0.00
(loc) I/dell Ud
n/a 999
- n/a 999
3 n/a n/a
PLATES GRIP
MT20 244/190
Weight: 22 lb FT = 0%
LUMBER
BRACING
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP No.2
BOT CHORD
Structural wood sheathing directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size) 1=227/7-10-13 (min. 0-1-8), 3=227/7-10-13 (min. 0-1-8)
Max Horz 1=-28(LC 13)
Max Upliftl= 94(LC 12), 3=-94(LC 13)
Max Grav1=260(LC 2), 3=260(LC 2)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2= 357/419, 2-3=-357/419
BOT CHORD 1-3=-308/286
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=S.Opsf; BCDL=S.Opsf; h=25ft; Cat. II; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.33 plate grip DOL=1.33
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 94 lb uplift at joint 1 and 94 lb uplift at joint 3.
8) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. .
LOAD CASE(S) Standard
oruss
russ Type
y
' .A01
1988
55256
�V[12
Valley Truss
1
1
Job Reference (optional)
I-- Jep L/ LU I G rflul[ /.JJU s Jep L/ LU IL MI I eK Inuuslfles. InG. mun uec 1 u umu I:uu eu iz race i
6-0-0 6-0-0
Scale = :18.9
4x4 =
2
5.00 F12
cc
ST1
3
1 +.
a Bi Y
o •o
o d
4
3x4 1.5x4 11 3x4
0- 10 12-0-0
021,011-11-6
Plate Offsets X 2:0-2-0 0-2-4
LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/dell Ud PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.48 Vert(LL) n/a n/a 999 MT20 244/190
TCDL 10.0 Lumber Increase 1.25 BC 0.42 Vert(TL) n/a n/a 999
BCLL 0.0 ' Rep Stress Incr YES WB 0.15 Horz(TL) 0.00 3 n/a n/a
BCDL 10.0 Code FR02010frPI2007 (Matrix) Weight: 37 lb FT = 0%
LUMBER BRACING
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 cc purlins.
BOT CHORD 2x4 SP No.2 BOT CHORD Structural wood sheathing directly applied or 10-0-0 cc bracing.
OTHERS 2x4 SP No.3 MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
REACTIONS (lb/size) 1=159111-10-13 (min. 0-1-8), 3=159/11-10-13 (min. 0-1-8), 4=416/11-10-13 (min. 0-1-8)
Max Horz1=44(LC 12)
Max Upliftl= 85(LC 12), 3=-93(LC 13), 4=-135(LC 12)
Max Grav 1=188(LC 27), 3=188(LC 28), 4=474(LC 2)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
WEBS 2-4= 367/383
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=l60mph (3-second gust) Vasd=124mph; TCDL=S.Opsf; BCDL=5.Opsf; h=25ft; Cat. 11; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.33 plate grip DOL=1.33
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 85 Ito uplift at joint 1, 93 lb uplift at joint 3 and
135 lb uplift at joint 4.
8) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
Job
I russ
I russ I ype
Qty
y
A0131989
55259
V14
Valley Truss
1
1
Job Reference o tional
Al ROOF TRUSSES, FORT PIERCE, FL 34946 Run: 7.350 s Sep 27 2012 Print: 7.350 s Se 3 27 2012 MTek Industries, Inc. Mon Dec 10 09:01:01 2012 Page 1
I D:Sf937j39GsZkf NbV2?PL3_yBJmX-KSg WgghsPBO1 m?7exogb5F1 a5YcZSKBRVvnCtsyAQAN
7-3-0 14-6-0
7-3-0 7-3-0
44 =
v
a
a
Scale=1:22.9
•
3x4 �
a
1.5x4 11
7
1.5x4 11
s
1.5x4 11
3x4
0- 10
14-6-0
0- -109
14-5-6
LOADING (psf)
SPACING
2-0-0
CSI
DEFL
in (loc)
I/defl
Ud
PLATES GRIP
TCLL 20.0
Plates Increase
1.25
TC 0.26
Vert(LL)
n/a
n/a
999
MT20 244/190
TCDL 10.0
Lumber Increase
1.25
BC 0.12
Vert(TL)
n/a
n/a
999
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.14
Horz(TL)
0.00 5
n/a
n/a
BCDL 10.0
Code FRC2010/TP12007
(Matrix)
Weight: 48 lb FT = 0
LUMBER BRACING
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP No.2 BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3 MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS All bearings 14-4-13.
(lb) - Max Horz 1= 55(LC 13)
Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 7 except 8=-181(LC 12), 6— 181(LC 13)
Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=291(LC 2), 8=312(LC 27), 6=312(LC 28)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
WEBS 2-8=-303/377, 4-6= 303/377
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft; Cat. 11; Exp C; Encl., GCpi=0.18;
MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.33 plate grip DOL=1.33
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ito uplift at joint(s) 1, 5, 7 except Qt=1b)
8=181,6=181.
8) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
THE / \ MARK/TRUSS LABEL REPRESENTS THE LEFT SIDE OF EACH TRUSS DRAWING
LOADING
ROOF
FLOOR
WIND LOAD
a s
O O
f- v
LIVE LOAD
20
*
ASCE 7-10
DEAD LOAD
10
*
160 MPH
F- o
m u
LIVE LOAD
10*
*
CATEGORY I I
DEAD LOAD
10
EXPSOSURE C
JULIUS LEE P.E.
1109 COASTAL BAY
BOYNTON BEACH, FL 33435
FL P.E.# 34869
TOTAL LOAD
40
*
BLDG CODE
FRC - 2010
TPI - 2007
DURATION FACTO
1.25
1.00
A•' .
1 YOLDT REVIEWED AND
APP Oi/ED/ PP-" iVED AS NOTED
I- R COMPL;,-'JgCE WITW
ARCH I ECTURI RAININGS
9' 6" 15' 0" 9 6" (3)2x BEAM BY OTHERS
TOP ® 10'-0"
FOR BRACING 8r ERECTION DETAILS REFER TO BCSI-03 AND/OR ENGINEER OF RECORD
HANGER
SYM
HANGER
DRAWN
JG
REV
DATE
BY
DESCRIPTION
It is understood that above
conditionshave been
ondi
APPROVED AS NOTED REVISE &RESUBMIT
BUILDER
JU524/LUS24
GD
M5H422/THA422
&
reviewed are acceptable far
ar
the fabrication at trusses,
elevations,pitches,overhangs,
%scias,ceiling
elevations/pitches, bearing
conditions 8 all detail
APPROVED REIECTED
JUS26/LUS26
®
HHUS46
DATE
12/10/12
2
/--/--
- *
*
JOB NAME
HD26/HTU26
J
THJA26
SCALE
N.T.S.
3
—/--/--
*
*
/HTU28
4
—/--/—
-*
pertaining to this truss
placement plan. No back
charges will io accepted
without previous written
approval from an A-1 Roof
Trusses representative.
REVIEWED BY: DATE:
Address
10B #
55256
/HTU26-2
L
- -
5
—/--/—
-*
*
/HTU28-2
BY OTHERS
SQ./FT.
-0
6
_/__/_
*
*
COUNTY
21611� 5
41/16"
2' 4 5/8"
TYPICAL END DETAIL
YCULLEN REPAIRS
.OWAY GUEST HOUSE ROOF
'016A40 TRUSSES
DUNN ROAD FORT PIERCE
LUCIE
A FLORIDA CORPORATION
Ph 772409-1010 / Fax 772409-1020
htfpl/www.alhuss.com