Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSDATE: FEES IU.,1 ( - n I RECEIPT #: - I Permit #: 1. Location/Site Address: Planning & Development Services Department Building & Code Regulation Division 2300 Virginia Avenue Ft. Pierce, FL 34982-5652 CANN"O Tel. 772-462-1553 St Q y APPLICATION FOR ROOF PERMIT `ucie Count SEE REVERSE SIDE FOR INSTRUCTIONS -l[�77� 1�iillf3 _npll Awfii0 �-�V __ �-L 3yg51 2. Parcel ID Number: 14. `d�4 Office Use Only Section Township Range Map Page I Zoning Land Use I Initials 3. Description of Project or Work Activity: v 4. Total Roof Area (square feet): 2-4Q� 5. Roof Pitch: 6.. Type of Roof. ><] Fiberglass Shingle [ ] Concrete Roof Tile [ ] Tar & Gravel [ ] Modified Bitumen 01 [ ] Wood Shake / Shingle [ ] Other [ ] Product Approval required for all types of Roofing Material (2 Sets) ] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product Approval. attached ** Roof Mitigation per F.S. 553.844 will be required. 7. Owner Information 8. Contractor Information Name: abi lent WAf rsw Address: 54bZ Y)111QJr)W Aft City:., F&P i tfeQ State: FL Zip:,2M5k Phone: D� FL Reg/Cert #: County Cert #: o V � f 7 Business Name: Nr,C,�ri �trvi S ln� Cell Phone:(1 I •���t 9. Value of Construction: $. "Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval. CONTRACTORIOWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in co pliance with all applicable laws regulating construction and'zoning: JC)I�,r) � s PRINT QUALIFIERS/OWNERS NAME S ATURE OF QUALIFIER/OWNER STATE OF FLORIDA, COUNTY OF zv� (- ACKNOWLEDGED BEFORE METHIS 13�DAY OF T V Q V� 20j, BY g 1 kf4l WHO IS PERSONALLY KNOWN�I O ME OR HAS PRODUCED SIGNATURE OF NOTARY TYPE OR PRINT NAME OF NOTARY t COMMISSION NUMBER NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEME FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FIN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Revised 4/26/2010 - ECCE�xPs'`1-R-E TION f YOUR PAYING TWICE YOUR LENDER OR INSTRUCTIONS Please complete all information in the space provided. All information must be printed (use black or blue ink only) or typed. This roof permit application is to be used only for those activities that are not otherwise included under a primary building permit. This application may not be used for any activity. that includes structural alteration. Building activities involving structural alteration, in addition to the roof work, must be permitted through the regular building permit review process. The information to be provided with this application includes: 1. Location/Site Address 2. Parcel ID Number 3. Description of Project or Work Activity 4. Total Roof Area 5. Type of Roof 6. Owner Information 7. Contractor Information 8. Value of Construction Indicate the street address or general location of the property where the building activity is taking place. Indicate the tax identification number of the property where the building activity is taking place. Completely describe the building activity to take place. Please indicate if tear -off or shingle over shingle etc. Indicate total roof area to be affected by this permit. Also indicate the pitch of the roof, expressed as a standard ratio of run rise. Indicate the type of roof being repaired or resurfaced. Indicate the name and address of the owner of the property on which building activity is taking place. Indicate the State of Florida registration number (if applicable), St. Lucie County contractor license number and the name of the business doing the work. Indicate the total value of the work to take place. Total cost of construction includes all material and labor costs associated with the building/construction activity. Construction value is used to determine the permit fee. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction. This application can be submitted to St. Lucie County Building and Zoning, 2300 Virginia Avenue, Fort Pierce, FL 34982. All permit applications must be filled out completely before submission. No applications will be accepted for processing after 4:30 P.M. For assistance in completing this application, please call (772) 462-1553, during regular office hours (8:00 AM - 5:00 PM), Monday through Friday. Upon issuance of this permit, required inspections can be scheduled by calling (772) 462-1261. St Lucie County Roof Permit Application rev. 3/1/2009 JOSEPH E. SMITH, CLERK OF THE CIRCUIT COURT — SAINT LUCIE COUNTY FILE # 3785192 OR BOO 169 PAGE 341, Recorded 01/02/2013 a -1:16 AM i Permit No. NOTICE OF�,CQMMEN,C{EMENT G Tax Folb No. tt.7� �' �� `t •�� ".� '! State of pmWa County of St. Lude Tiro undersigned h ereby gives notice that Improvement will be made to rsrtsin real property, and in accordance with Chapter 713, Florida Statutes, the following k1for rnation is provided In this Notk a of Commencement. General dasa d lmpova W-2b►MV - A Owaer loft a Mosm dort If theJJJaLm contracted for the Improvement: Name _ Address4 But, Interest In prop�`f Name and fee simple titleholder (If different from Owner listed above): Cooursoes Contractor sooty (d oppl , a copy of the payment bond Is attacited): Amount of bond: S Name and addre Phone number: Laadar Names Phone Number. Lendses address: Peraoas wkNk a Steme alponder deskmaW by OvineraPoo wlmm notices or other documents stay be sawed as provided by section ZUAX1) (a)7., F orlda steatem Name: Phone Number. Address: In addition to hin self or herself, Owner designates of to receive a copy of the Lienoes Notice a pralded in Section 713.UM (b), Florida Statutes. Phone number Mesa" a er►tllY designated by owner. Expiration date notice of comnencament: (the expiration date may not be before the completion of oxwostructbn and final payment to the oontracor, I ba 1 year from the date of ram img unless a different date Is specified) WARNWGTO ER: ANY PAYMENTS MADEBYTHEOWNERAFTERTHEEXPIRATIONOFTHENOTICEOFCOMMENCEMENT ARE CONSIDERED IMPROPER PA NTS UNDER WAFTER 713, PART 1, SECTION 7]313, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS YOUR PROPERTY. A NOTICE OF T MUST � � �� ONT�� � � THE F1IST INSPECTION. IF INTENDTOOBTAINFINANCING,00NSULTWLTHYOURLENDERORANATTORNEYBEFORECOMMENaNGWORKOR RECORDING YOU I NOTICE OF COMMENCEMENT. Under penalty of perjury, I declare that I haw read the foregoing notice of commencement and that the facts stared therein am tree to the bat of :mv�know(edee, essee, or Owners or Lessees Authorized Off1cer1Dkeaar/Ps1tner/Manager (Slputory'sli ) The foregoingI twas acknowledged beforemethls_L(.—dayof V &, 2019- BY r as //entsrrl t /` for Name o ^ .JOSS Type of authority (04• officer, trustee) Party on behalf of whom irtstrurnent was executed 6 krownl%r produced Identification_ of N tary P-State of Florida) maums Yicationproduced (Pent, Type, or Stamp Commissioned Name ref oil 10i, STATE OF FLORIDA ST, LUCIE CONTY T11161S TO CERTIFY THAT TWIQ IC A l — 1P.gc 2 of 2 2013-01-03 1 B:24: 40 (GMT) 17727940409 From: Ma11— Cola amp C6UNTY . F L O R I D A Re: Permit # I so I Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 772-462-2165 or 772-462-2172 Fax: 772-462-6443 ROOF INSPECTION AFFIDAVIT I On" �.L;.S 5 ,licensed as a(9 Contract */Engineer/Architect (Please print name & circle license type) *FS4 Ina Inspector *General, Building, Residential or Roofing Contractor or any individual certified under 468 F.S. to make such an inspection. On or about I did personally inspect the roof deck nailing ( ate) work at:.Bqw (44 site address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S.) Signature and Seal License # STATE OF F OR COUNTY S�wo q-� and sub scr�bed before me this _ day of �.><1 Tf'J 20� %S� . Who is personally Imown to me or who has produced as identification. " % Notary Public, State Hof orid� Signature of Notary:, Commission Number: En 01/19/2011 (Sea() a. ..Y�.r'^'�ls ti.I 1w! �r"+w."— '•+� �a 10/' 4�f 1 fCp.N34elh: 4 f3'.=t�'.' T V. SiA'S•a?A.tif.tiF ccc a:��:F� (772) 794-0408 Fax: (772) 794-0409 To: Peterson Residence June 12, 2012 Location: 5400 Killarney Avenue & ), 0 OQP , Fort Pierce, FI 34951 ���% r/ 1 Dimensional Shingle Re -Roof ➢ Obtain a Re -Roofing Permit. o PY ➢ Remove old roof down to wood decking. FILL,. ➢ HannaBd is responsible for the removal and hauling of old roof debris. ➢ Inspect all wood decking or sheeting for any water damage. ➢ Any damaged plywood decking replacement is an additional charge of $2.00 per square foot and replacement of soffit, fascia and/or sub -fascia $6.00 per foot over the estimated price. (Does not include any structural framing.) (2) sheets of wood replacement are included in contract. ➢ Re -nail decking to meet current Florida Building Codes. (using 8d full ring -shank fasteners six inches on center. ➢ The entire wood roof deck shall be covered with 30# felt paper with the use of tin tags. ➢ Install 210' of 2x2 inch eave metal to be mechanically fastened to code with ring -shank fasteners. ➢ Install 53' of valley. ➢ Install (5) new lead plumbing boots (1) electrical mast. ➢ Install 175' shingle "High Ridge" to replace what is existing. ➢ Removal and re -installation of 108' of gutter around home is included in our contract. ➢ Install a 40yr True Def (Harbor Blue) Dimensional roof system over entire pitched roof surface to match what is existing, to be mechanically fastened to Florida building code and/or manufacture's specifications. with ring -shank fasteners. Line Item: Add an additional $325.00 to contract price for the use of a secondary water barrier in lieu of 30# felt paper underlayment. Five year warranty on workmanship, guaranteed, effective on final invoice date. All quotes are good for 15 days upon receipt After 15 days, quote will be reevaluated to include any price changes to supplies and materials needed to perform the above stated description. Any extra roofing systems found while performing a reroof, will bean additional charge of $50.00 per every 100 square feet. All material is guaranteed to be as specified. All work to be completed in a workmanlike manner according to standard practices. Any alteration or deviation from above specifications involving extra cost will be executed only upon written orders, and will become an extra charge over and above the estimate. All agreements are contingent upon strikes, accidents or delays beyond our control. Owner is to carry fire, tornado and other necessary insurance. Our workers are fully covered by workmen's compensation insurance. Not responsible for existing wall paint, gutters, landscaping, sidewalks and irrigation. Total for Shingle Re -Roof: $8,385.00 Payment Methods: Payments to be disbursed as follows: ❑cash 25% Down to Start - $2,096.25 ❑Check/Money Order 50% In Mid Process - $4,192.50 ❑Mastercard ❑Visa 25% Upon Completion - $2,096.25 Complete if Using Credit/Debit Card: Name as Appears on Card Account # 3 Digit Security Code Amount Authorized $ Signature of Card Holder Contractor Property Owner Exp Date Date /2 Date��- Florida Building Code Online Page 1 of 2 FL # FL10124-R7 Application Type Editorial Change Code Version 2010 Application Status Approved Comments Archived Product Manufacturer GAF Address/Phone/Email 1361 Alps Road Wayne, NJ 07470 (973)872-4421 Iindareith@trinityerd.com Authorized Signature Beth McSorley Iindareith@trinityerd.com Technical Representative Beth McSorley Address/Phone/Email 1361 Alps Road - Bldg 11-1 Wayne, NJ 07470 (973)872-4421 BMcSorley@gaf.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who Robert Nieminen developed the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 07/31/2013 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL10124 R7 COI Trinity ERD CI - Nleminen.odf Referenced Standard and Year (of Standard) Standard Year ASTM D3161 (Class F) 2006 ASTM D3462 2007 ASTM D7158 (Class H) 2007 TAS 107 1995 Equivalence of Product Standards http://www.floridabuilding.org/pr/pr_app_dtl.aspx?paratn=wGEVXQwtDquracBeVCbdMQ... 1 /2/2013 Florida Building Code Online -- Page 2 of 2 Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Date Revised Method 1 Option D 04/04/2012 04/25/2012 04/29/2012 06/11/2012 10/22/2012 ................................ . Summary of Products FL # Model, Number or Name IlDescription 10124.1 GAF Asphalt Roof Shingles Fiberglass reinforced 3-tab, laminated, 5-tab and j hip/ridge asphalt shingles j Limits of Use Approved for use in HVHZ: No Installation Instructions FL10124 R7 II er041912FINAL GAF Asphalt Shingles FL10124-R7.Ddf Verified By: Robert Nieminen PE-59166 Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to ER, Section 5. Evaluation Reports FL10124 R7 AE er041912FINAL GAF Asphalt Shingles FL1.0124-R7.odf Created by Independent Third Party: Yes sack Next Contact Us :: 1940 North Monroe Street, Tallahassee Fl- 32399 Phone: 850-487-1824 The State of Florida is an WEED employer. Cooyriaht 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: z't hsci 12 Sccaritv�ssTs�tc- x http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquracBeVCbdMQ... 1 /2/2013 Q0_rFuN1TYJ'ERD EVALUATION REPORT GAF 1361 Alps Road, Building,7-3 Wayne, NJ 07470 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX:(203) 262-9243 Evaluation Report 01506.01.08-119 FL10124-R7 Date of Issuance: 01/03/2008 Revision 9: 04/19/2012 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2010 Florida Building Code sections noted herein. DESCRIPTION: GAF Asphalt Roof Shingles LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinitylERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 4. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 04/19/2012 This does not serve as an electronically signed document. Signed, sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. TrinitylERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved In the approval process of the product. a T .ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2007 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161, Class F 2006 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158, Class H 2O07 1507.2.7.1, R905.2.6.1 Wind Resistance TAS 107 1995 3. REFERENCES: Entity Examination Reference Date GAF (PDM 1915) Letter of Equivalency Seal -A -Ridge Impact Resistant IR 01/13/2012 PRI(TST 5878) ASTM D3462 GAF-059-02-01 09/02/2004 PRI (TST 5878) ASTM D3462 GAF-080-02-01 05/25/2005 UL (TST 1740) ASTM D3462 93NK6295 11/29/1993 UL (TST 1740) ASTM D3462 99NK43835 01/12/2000 UL (TST 1740) TAS 107 94NK9632 03/29/2000 UL(TST.1740) ASTM D3462 01NK06632 02/02/2001 UL (TST 1740) ASTM. D3161, TAS 107 01NK9226 05/21/2001 UL (-TST 1740) ASTM D3161 OINK37122 12/18/2001 UL (TST 1740) ASTM D3462 OINK37122 12/19/2001 UL (TST 1740) ASTM D3161, TAS 107 02NK12980 04/10/2002 UL (TST 1740) ASTM D3161, TAS 107 02NK30871_ 09/09/2002 UL (TST 1740) ASTM D3161 03CA5367 03/11/2003 UL (TST 1740) ASTM D3462 03NK26444 10/17/2003 UL (TST 1740) ASTM D3462 04NK13850 06/07/2004 UL (TST 1740) ASTM D3161 04NK13850 06/23/2004 UL (TST 1740) ASTM D3161 04NK30546 03/10/2005 UL (TST 1740) ASTM D3462 04NK22009 05/06/2005 UL(TST 1740) ASTM D3161 04NK22009 05/09/2005 UL (TST 1740) ASTM D3462 05NK27924 02/10/2006 UL (TST 1740) ASTM D3161 05NK27924 02/11/2006 UL (TST 1740) ASTM D3161,D3462 06CA18077 06/05/2006 UL (TST 1740) ASTM D3161, D3462 06CA18074 06/16/2006 UL (TST 1740) ASTM D3161, D3462 06CA35251 10/18/2006 UL (TST 1740) ASTM D3462 06CA31603 12/01/2006 UL (TST 1740) ASTM 133161,133462 06CA41095 12/27/2006 UL (TST 1740) ASTM D3161 07NK05228 03/13/2007 UL (TST 1740) ASTM D3161 06CA31611 04/04/2007 UL (TST 1740) ASTM D3161 06CA61148 04/09/2007 UL (TST 1740) ASTM D3161, D3462 07CA31742 11/08/2007 UL (TST 1740) ASTM D3161, D7158, D3462 08CA06100 03/13/2008 UL (TST 1740) ASTM D3161, D3462 07CA55908 04/01/2008 UL (TST 1740) ASTM D3161,133462 09CA10592 03/26/2009 UL (TST 1740) ASTM D3161, D3462 09CA06856 05/15/2009 UL (TST 1740) ASTM D3161, D7158, D3462 09NK06647 08/01/2009 UL (TST 1740) ASTM D3161, D7158, D3462 09CA27281 08/27/2009 UL (TST 1740) ASTM D3161, D7158, D3462 IOCA35554 03/05/2010 UL (TST 1740) ASTM D3161, D7158, D3462 10CA13686 05/15/2010 UL (TST 1740) ASTM D3462 IOCA07264 05/27/2010 UL(TST 1740) ASTM D3462 IOCA11953 10/29/2010 UL (TST 1740) ASTM D3161, D7158, D3462 1ONK11951 10/30/2010 UL (TST 1740) ASTM D3161, D7158, D3462 IONK12070 11/04/2010 UL (TST 1740) ASTM D3161, D7158, D3462 08CA06100 01/30/2010 UL (TST 1740) ASTM D3161, D7158, D3462 10CA53934 03/31/2011 UL (TST 1740) ASTM D3161, D7158, D3462 11CA48924 10/22/2011 Exterior Research and Design, LLC. Evaluation Report 01506.01.08-1117 Certificate of Authorization #9503 FL10124-R7 Revision 9: 04/19/2012 Page 2 of 4 UL (TST 1740) UL (TST 1740) UL (TST 1740) UL, LLC. (QUA 9625) UL, LLC. (QUA 9625) 4. PRODUCT DESCRIPTION: ASTM D3161, D7158, D3462 ASTM D3161, D7158, D3462 ASTM D3161, D7158, D3462 Quality Control Quality Control F"<) `J I RINIIY I ERD IICA47919 12/03/2011 11CA48408 12/08/2011 11CA48725 12/09/2011 Inspection Report, File No. R21 02/06/2012 R3915 Current 4.1 Marquis WeatherMax, Royal Sovereign and Sentinel are a fiberglass reinforced, 3-tab asphalt roof shingles. 4.2 Camelot, Camelot II / Camelot 30, Capstone, Country Mansion, Country Mansion II, Grand Canyon, Grand Sequoia, Grand Slate, Grand Slate II, Monaco, Timberline American Harvest, Timberline ArmorShield II, Timberline Natural Shadow, Timberline Natural Shadow Arctic White, Timberline HD / Timberline Prestique 30, Timberline Prestique 40 / Timberline Cool Series, Timberline Ultra HD / Timberline Prestique Lifetime, Timberline Majestic / Timberline Majestic 30 and Woodland are fiberglass reinforced, laminated asphalt roof shingles. 4.3 Slateline is a fiberglass reinforced, 5-tab asphalt roof shingle. 4.4 Seal -A -Ridge, Seal -A -Ridge Armorshield, Seal -A -Ridge Impact Resistant IR, Ridglass 8, Ridglass 10, Ridglass 12 and Timbertex Hip and Ridge are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.5 ProStart Starter Strip Shingles and WeatherBlock& Starter Strip Shingles are a starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVHZ. 5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.3 Wind Classification: 5.3.1 All GAF shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for us in all wind zones up to Vasd = 150 mph (V,it. = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.3.2 All GAF hip & ridge shingles noted herein are. Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for us in all wind zones up to Vasd = 150 mph (Vuit = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.3.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C. Rule 9N-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 9N-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Starter Shingles: Exterior Research and Design, LLC. Evaluation Report 01506.01.08-1117 Certificate of Authorization #9503 FL10124-R7 Revision 9: 04/19/2012 Page 3 of 4 QT INITY I ERD 6.2.1 Installation of ProStart Starter Strip Shingles and WeatherBlocker Starter Strip Shingles shall comply with the manufacturer's current published instructions. 6.3 Asphalt Shingles: 6.3.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following exceptions: ➢ Camelot, Camelot II / Camelot 30, Grand Slate II, Country Mansion II, Monaco and Woodland require minimum five (5) fasteners per shingle 6.3.2 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the shingle manufacturer for details. 6.4 Hip & Ridge Shingles: 6.4.1 Installation of Ridglass 8, Ridglass 10 and Ridglass 12 asphalt shingles shall comply with the manufacturer's current published instructions with a minimum two (2) nails per side [total of four (4) nails per shingle] and asphalt roofing cement. 6.4.2 Installation of Seal -A -Ridge, Seal -A -Ridge Armorshield and Seal -A -Ridge Impact Resistant IR asphalt shingles shall comply with the manufacturer's current published instructions with a minimum two (2) nails per shingle. 6.4.3 Installation of Timbertex Hip and Ridge asphalt shingles shall comply with the manufacturer's current published instructions with a minimum two (2) nails per shingle and beads of Sonneborn NPi Gun Grade Polyurethane Sealant or Henkel PL Roofing and Flashing Sealant. 6.4.4 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 7. LABELING: 7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. S. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC — QUA9625; (847) 664-3281 - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report 01506.01.08-117 Certificate of Authorization #9503 FL10124-R7 Revision 9: 04/19/2012 Page 4 of 4 FL # FL5259-R16 Application Type Revision Code Version 2010 Application Status Approved Comments Archived Product Manufacturer POLYGLASS USA Address/Phone/Email 150 Lyon Drive Fernley, NV 89408 (570)384-1230 Ext242 jaklns@polyglass.com Authorized Signature James Akins jaklns@polyglass.com Technical Representative Steve Wadding Address/Phone/Email 150 Lyon Drive Fernley, NV 98408 (602)363-7139 stevew@polyglass.com Quality Assurance Representative James Akins Address/Phone/Email 555 Oakridge Road Humboldt Industrial Pkwy Hazleton, PA 18201 (800) 894-4563 jaklns@polyglass.com Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who Robert Nleminen developed the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 08/08/2015 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL5259 R16 COI Trinity ERD CI - Nieminen.odf Referenced Standard and Year (of Standard) Standard Year ASTM D1970 2001 ASTM D226 2006 ASTM D6164 2005 http://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgvbSgAaZp3 Crk2... 1 /2/2013 Florida Building Code Online,—, Page 2 of 2 f , Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Date Revised ASTM D6222 2002 ASTM G154 2005 ASTM G155 2005 FM 4474 2004 FRSA/TRI07320 2005 TAS 103 1995 Method 1 Option D 08/17/2012 08/21/2012 08/27/2012 10/09/2012 12/07/2012 Summary of Products FL # Model, Number or Description j Name j 5259.1 Polyglass Roof Roofing underlayments Underlayments Limits of Use Installation Instructions Approved for use in HVHZ: No FL5259 R16 II er081712FINAL POLYGLASS UNDERLAYMENTS FL5259- R16.odf Approved for use outside HVHZ: Yes Verified By: Robert Nieminen PE-59166 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-622.5 Evaluation Reports Other: 1.) The design pressure in this FL5259 R16 AE er081712FINAL POLYGLASS UNDERLAYMENTS FL5259- R16"Ddf application relates to one particular underlayment system for use under Created by Independent Third Party: Yes foam -on tile systems. Refer to ER Section 5.5.2 for other systems and maximum design pressures. 2.) Refer to ER Section 5 for other limits of use. Back Next Contact Us :: 1940 North Monroe Street Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. Copyright 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: WeRhtcX �Y:Cpt"i M£"e fILSCs A http://www.floridabuilding.org/pr/pr_app_dtl.aspx?paratn=wGEVXQwtDgvbSgAaZp3 Crk2... 1 /2/2013 . " . - / "--\ 1 11 �-1 4 Q h tv" EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 �TRINIIY ERD OXFORD, CT 06478 PHONE: (203) 262 9245 FAX: (203) 262-9243 EVALUATION REPORT Polyglass USA, Inc. Evaluation Report P12060.02.09-1111 150 Lyon Drive FL5259-1116 Fernley, NV 98408 Date of Issuance: 02/24/2009 Revision 11: 08/17/2012 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use' of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building .Code, Residential Volume. The products described herein have been designed to comply with the 2010 Florida Building Code sections noted herein. DESCRIPTION: Polyglass Roof Underlayments LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinityJERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 10. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 08/17/2012 This does not serve as an electronically signed document. Signed, sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinityJERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity) ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity Involved in the approval process of the product. P�RJNITY If ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. , STANDARDS: Section Property Standard Year 1507.2.3, 1507.3.3, 1507.5.3, 1507.7.3 1507.8.3 1507.9.3 Physical Properties ASTM D226 2006 1507.2.4, 1507.2.9.2, 1507.3.3, 1507.5.3 Physical Properties ASTM D1970 2001 1507.11.2 Physical Properties ASTM D6164 2005 1507.11.2 Physical Properties ASTM D6222 2002 1504.6 Accelerated Weathering ASTM G154' 2005 1504.6 Accelerated Weathering ASTM G155 2005 1504.3.1 Wind Uplift FM 4474 2004 1507.3.3 Installation Practice FRSA/TRI 07320 2005 1523.6.5.2.1 Physical Properties TAS 103 1995 3. REFERENCES: Entity Examination Reference Date FM Approvals (TST 1867) Wind Uplift 3004091 01/12/2000 PRI (TST 5878) Physical Properties PRIO1111 04/08/2002 PRI (TST 5878) Physical Properties PUSA-005-02-01 01/31/2002 PRI (TST 5878) Physical Properties PUSA-013-02-01 12/23/2002 PRI (TST 5878) Physical Properties PUSA-013-02-02 12/23/2002 PRI (TST 5878) Physical Properties PUSA-013-02-03 12/23/2002 PRI (TST 5878) Physical Properties PUSA-018-02-01 07/14/2003 PRI (TST 5878) Physical Properties PUSA-028-02-01 07/13/2005 PRI (TST 5878) Physical Properties PUSA-033-02-01 01/12/2006 PRI (TST 5878) Physical Properties PUSA-035-02-01 09/29/2006 PRI (TST 5878) Physical Properties PUSA-055-02-02 12/10/2007 PRI (TST 5878) Physical Properties PUSA-061-02-02 01/28/2008 PRI (TST 5878) Physical Properties PUSA-076-02-01 02/22/2008 PRI (TST 5878) Physical Properties PUSA-083-02-01 04/14/2008 PRI (TST 5878) Physical Properties PUSA-088-02-01 07/29/2009 MTI (TST 2508) Physical Properties JX20H7A 04/01/2008 MTI (TST 2508) Physical Properties RX14E8A 01/29/2009 ERD (TST 6049) Physical Properties 11752.09.99-1 02/08/2000 ERD (TST 6049) Wind Uplift 11776.06.02 01/16/2003 ERD (TST 6049) Physical Properties 02200.07.03 07/14/2003 ERD (TST 6049) Wind Uplift P1740.01.07 01/04/2007 ERD (TST 6049) Physical Properties P5110.04.07-1 04/11/2007 ERD (TST 6049) Wind Uplift P9260.03.08 03/21/2008 ERD (TST 6049) Physical Properties P13450.08.09 08/13/2009 ERD (TST 6049) Wind Uplift P30540.11.09-111 11/30/2009 ERD (TST 6049) Physical Properties P33360.06.10 06/25/2010 Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R11 Certificate of Authorization #9503 FL5259-R16 Revision 11: 08/17/2012 Page 2 of 10 r , TRINITY I ERID Entity Examination Reference Date ERD (TST 6049) Physical Properties P33370.03.11 03/02/2011 ERD (TST 6049) Physical Properties P33370.04.11 04/26/2011 ERD (TST 6049) Physical Properties P40390.08.12-1 08/06/2012 ERD (TST 6049) Physical Properties P40390.08.12-2 08/07/2012 ICC-ES (EVL 2396) IBC Compliance ESR-1697 11/01/2011 Miami -Dade (CER 1592) HVHZ Compliance NOA Current Polyglass USA Manufacturing Affidavit Products Current 02/18/2009 Polyglass USA P/L Affidavit Mule -Hide Cross Ltg 03/01/2008 Polyglass USA Materials Affidavit Polystick SA Compound 08/18/2011 UL, LLC. (QUA9625) Quality Control Service Confirmation Exp. 08/08/2015 4. PRODUCT DESCRIPTION: 4.1 Mechanically Fastened Underlavments: 4.1.1 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet. 4.1.2 Elastobase P is a polyester -reinforced, SBS modified bitumen base sheet. 4.2 Self -Adhering Underlavments: 4.2.1 Polystick MTS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced with polyolefinic film surface; meets ASTM D1970 and TAS 103. 4.2.2 Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an aggregate surface; meets ASTM D1970. 4.2.3 Polystick TU is a nominal 100-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a granular surface; meets ASTM D1970 and TAS 103. 4.2.4 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a polyester fabric surface; meets ASTM D1970 and TAS 103. 4.2.5 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass- fiber/polyester reinforced, with a granular surface; meets ASTM D1970 and TAS 103. 4.2.6 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 170 g/m2 polyester fabric surface; meets TAS 103. 4.2.7 Polyflex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet .(FR) are a polyester reinforced, APP modified bitumen cap sheets. 4.2.8 Dual ProTM is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface. 4.2.9 Tile ProT"' is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface. 4'.3 Mechanically Fastened and/or Bonded Underlavments: 4.3.1 Elastoflex S6G and Elastoflex S6G FR are polyester reinforced, SBS modified bitumen cap sheets. 4.3.2 Polyflex G and Polyflex G FR are polyester reinforced, APP modified bitumen cap sheets. S. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVHZ.. 5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R11 Certificate of Authorization #9503 FL5259-Ri6 Revision 11: 08/17/2012 Page 3of10 UD RINITY i ERD. 5.3 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the AH] for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.4 Allowable roof covers applied atop the underla ments are as follows: Table 1: Roof Cover Options Underlayment Asphalt Nail -On Tile Foam -On Metal Wood Shakes & Slate Shingles Tile Shingles Elastobase Yes Yes No Yes Yes Yes Elastobase P Yes Yes No Yes Yes Yes Polystick MTS Yes Yes No Yes Yes Yes Polystick IR-Xe Yes No No No Yes Yes Polystick TU Yes Yes Yes No Yes Yes See 5.4.1 Polystick TU P Yes Yes See es 5.Polystick No Yes Yes TU Plus Yes Yes es Yes Yes Yes See 5.Polystick TU Max No Yes Yes No No No See 5 4.1 Dual Pro Yes Yes No Yes Yes Yes Tile Pro Yes Yes See es 5.Elastoflex Yes Yes Yes S6G or S6G FR Yes Yes No No Yes Yes Polyflex G or G FR Yes Yes See es 5.Polyflex No Yes Yes SAP or SAP FR Yes Yes See es 5.Mule-Hide No Yes Yes SA-APP Cap Sheet Yes Yes Yes No Yes Yes or SA-APP Cap Sheet (FR) See 5.4.1 5.4.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives unless tensile adhesion / long term aging data from an accredited testing laboratory is provided. ➢ Polyfoam PolyPro AH160: Polystick TU, Polystick TU P, Polystick TU Plus, Polyflex G, Polyflex G FR, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule - Hide SA-APP Cap Sheet (FR) or Tile Pro. ➢ 3MTm 2-Component Roof Tile Adhesive AH-160: Polystick TU Max ➢ Dow TileBond: Polystick TU P, Polystick TU Plus, Polyflex SAP or Tile Pro 5.4.2 For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the tile. 5.4.3 A 2-ply underlayment system, consisting of Polystick MTS followed by Polystick MTS, TU, TU P, TU Plus or TU Max, or Polyflex SAP is allowable for use under mechanically attached prepared roof systems. This is not a requirement, but is allowable if a 2-ply underlayment system is desired. Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1111 Certificate of Authorization #9503 FL5259-1116 Revision 11: 08/17/2012 Page 4 of 10 5.5 Allowable substrates are noted below: 5.5.1 Direct -Bond to Deck: Polystick, Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: ➢ New untreated plywood; ➢ ASTM D41 primed new untreated plywood; ➢ Existing plywood; ➢ ASTM D41 primed existing plywood; ➢ ASTM D41 primed OSB; ➢ Southern Yellow Pine; ➢ ASTM D41 primed Southern Yellow Pine; ➢ ASTM D41 primed structural concrete; ➢ Huber Engineered Woods "ZIP System" Panels (designed and installed to meet wind loads for project). Note: Polyglass does not require priming of new or existing plywood sheathing. New or existing plywood sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes. Elastoflex S6G or S6G FR in hot asphalt to: ➢ ASTM D41 primed structural concrete. Polyflex G or G FR torch -applied to: ➢ ASTM D41 primed structural concrete. 5.5.2 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI 07320 does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI 07320 and are used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609.1.5 for determination of design wind pressures. 5.5.2.1 Maximum. Design Pressure = -622.5 psf. Deck: Structural concrete to meet project requirements to satisfaction of AHJ. Primer: ASTM D41 Underlayment: Polyflex G or G FR torch -applied. 5.5.2.2 Maximum Design Pressure = -315 psf. Deck: Structural concrete to meet project requirements to satisfaction of AHJ. Primer: ASTM D41 Underlayment: Polystick TU, Polystick TU P, Polystick TU Plus, Polystick TU Max, Tile Pro, Polyflex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR). 5.5.2.3 Maximum Design Pressure = -135 psf. Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ. Primer: (Optional) ASTM D41 Joints: Min. 4-inch wide strips of Elastoflex SA-V over all plywood joints. Underlayment: Polystick TU, Polystick TU P, Polystick TU Plus, Polyflex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1111 Certificate of Authorization #9503 FL5259-1116 Revision 11: 08/17/2012 Page 5 of 10 r I TRINITYERD 5.5.2.4 Maximum Design Pressure = -90 osf. Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ. Primer: (Optional) ASTM D41 Underlayment: Polystick TU, Polystick TU P, Polystick TU Plus, Polyflex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) 5.5.2.5 All other direct -deck, adhered Polyglass underlayment systems beneath foam -on tile systems carry a Maximum Design Pressure of -45 psf. 5.5.3 Bond=to-Insulation: ➢ Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: ASTM C1289, Type II, Class 1 polyisocya nu rate or Type V polyisocyanurate-composite insulation; DensDeck DuraGuard; DensDeck Prime; or SECUROCK Gypsum -Fiber Roof Board. ➢ Elastoflex S6G or S6G FR in hot asphalt to: DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board. ➢. Polyflex G or G FR torch -applied to: ASTM D41 primed structural concrete; DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile systems, insulation attachment shall_ be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4470, Appendix K or TAS 114, Appendix I 5.5.4 Bond to Mechanically Attached Base Layer: ➢ Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or Tile Pro self -adhered to: ASTM D226, Type I or II felt; Elastobase; Elastobase P or Mule -Hide Nail Base. ➢ Elastoflex S6G or S6G FR in hot asphalt to: ASTM D226, Type I or II felt; Elastobase; Elastobase P or Mule -Hide Nail Base. ➢ Polyflex G or G FR torch -applied to: Elastobase; Elastobase P or Mule -Hide Nail Base.. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam -on tile systems, base layer shall be attached per minimum requirements of FRSA/TRI 07320/8-05 or RAS 120. 5.6 Exposure Limitations: 5.6.1 Elastobase, Elastobase P, shall not be left exposed for longer than 30-days after installation. 5.6.2 Polystick IR-Xe, Polystick TU Max, Dual Pro or Tile Pro shall not be left exposed for longer than 90-days after installation. 5.6.3 Polystick MTS, TU, TU P or TU Plus shall not be left exposed for longer than 180-days after installation. 5.6.4 Polyflex SAP or SAP FR, or Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure limitation, unless the prepared roof covering is to be adhesive -set tile, in which case the maximum exposure is 30 days. 5.6.5 Elastoflex S6G or S6G FR or Polyflex G or G FR does not have an exposure limitation, unless the prepared roof covering is to be adhesive -set tile (Polyflex G or G FR only), in which case the maximum exposure is 180 days. Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1111 Certificate of Authorization #9503 FL5259-R16 Revision 11: 08/17/2012 Page 6 of 10 r" ti QTkINI 5.7 For the roof installations governed by the FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, use is limited to the following. Reference is made to the FRSA/TRI Technical Brief titled "Florida High Wind Roof Tile Self -Adhered Underlayment Requirements as of 02/14/2011" for limitations for self -adhering underlayments used beneath tile roof systems. Table 2: Tile System Options per FRSA/TRI 07320/8-05 System Underlay Option section Reference Product(s) 3.02A 1 Batten Modified Cap Sheet Elastoflex S6G or Elastoflex S6G FR; Polyflex G or G FR only No. 30 / Modified Cap Base Layer: Elastobase; Elastobase P System One: 2 3.028 Sheet Top Layer: Elastoflex S6G or Elastoflex S6G FR; Polyflex G Mechanically or G FR 4 3.02D No. 30 Elastobase; Elastobase P Fastened Tile, Unsealed or Self -Adhered Polystick MTS; TU; TU P; TU Plus; TU Max; Polyflex SAP or Sealed 5 3.02E Underlayment y SAP FR; Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet Underlayment (FR); Dual Pro; Tile Pro System Base Layer: ASTM D226, Type II; Elastobase; Elastobase P; No. 30 / Self -Adhered Mule -Hide Nail Base 6 3.02F Underlayment Top Layer: Polystick MTS; TU; TU P; TU Plus; TU Max; Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA- APP Cap Sheet (FR); Dual Pro; Tile Pro 3.02A 1 Batten Modified Cap Sheet Elastoflex S6G or Elastoflex S6G FR; Polyflex G or G FR only No. 30 / Modified Cap Base Layer: Elastobase; Elastobase P System Two: 2 3.02B Sheet Top Layer: Elastoflex S6G or Elastoflex S6G FR; Polyflex G Mechanically or G FR Self -Adhered Polystick TU; TU P; TU Plus; TU Max; Polyflex SAP or SAP Fastened Tile, Sealed 4 3.02D Underlayment FR; Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet Underlayment (FR); Dual Pro; Tile Pro System Base Layer: ASTM D226, Type II; Elastobase; Elastobase P; No. 30 / Self -Adhered Mule -Hide Nail Base 5 3.02E Underlayment Top Layer: Polystick TU; TU P; TU Plus; TU Max; Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro; Tile Pro 1 3.02A Modified Cap Sheet Polyflex G or G FR 2 3.02B No. 30 / Modifed Cap Base Layer: Elastobase; Elastobase P System Four Sheet Top Layer: Polyflex G or G FR Self -Adhered Polystick TU; TU P; TU Plus; TU Max; Polyflex SAP or SAP Adhesive -Set 4 3.02D Underlayment FR; Tile Pro; Mule -Hide SA-APP Cap Sheet or SA-APP Cap Tile, Unsealed or Sheet (FR) Sealed Base Layer: ASTM D226, Type II; Elastobase; Elastobase P; Underlayment Mule -Hide Nail Base System 5 3.02E No. 30 / Self -Adhered Underlayment Top Layer: Polystick TU; TU P; TU Plus; TU Max; Polyflex SAP or SAP FR; Tile Pro; Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) 1 3.02A No. 30 / Modified Cap Base Layer: ASTM D226, Type II; Elastobase; Elastobase P Sheet Top Layer: Polyflex G or G FR System Four Self -Adhered Polystick TU; TU P; TU Plus; TU Max; Polyflex SAP or SAP "B": 3 3.02C Underlayment FR; Tile Pro; Mule -Hide SA-APP Cap Sheet or SA-APP Cap Adhesive -Set Sheet (FR) Tile, Sealed Base Layer: ASTM D226, Type II; Elastobase; Elastobase P; Underlayment Mule -Hide Nail Base System 4 3.02D No. 30 / Self -Adhered Underlayment Top Layer: Polystick TU; TU P; TU Plus; TU Max; Polyflex SAP or SAP FR; Tile Pro; Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1111 Certificate of Authorization #9503 F11-5259-1116 Revision 11: 08/17/2012 Page 7of10 FTRINITYIERD 6. INSTALLATION: 6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 Elastobase, Elastobase P or Mule -Hide Nail Base: 6.3.1 Shall be installed in compliance with the codified requirements for ASTM D226, Type II underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.3.2 For use in non -tile applications: 6.3.2.1 Reference is made to the current edition of the NRCA Steep -slope Roofing Manual and ARMA recommendations for installing shingle underlayments and flashings 6.3.2.2 Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), Dual Pro or Tile Pro, self -adhered, Elastoflex S6G or S6G FR in hot asphalt or Polyflex G or G FR, torch applied. 6.3.3 For use in tile applications, reference is made to Polyglass published installation instructions in conjunction with FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein. 6.4 Polvstick MTS. IR-Xe. TU. TU P. TU Plus. TU Max Polvflex SAP or SAP FR. Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR). Dual Pro or Tile Pro: 6.4.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.4.2 For non -tile applications: 6.4.2.1 All self -adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) should be back -nailed in selvage edge seam in accordance with Polyglass / Mule -Hide Back Nailing Guide. Nails shall be corrosion resistant, 11 gauge ring -shank type with a minimum 1-inch diameter metal disk or Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back - nailed using the above noted fasteners and spacing, in area marked "nail area, area para clavar" on the face of membrane. The head lap membrane is to cover the area being back - nailed 6.4.2.2 All seal -lap seams (selvage laps) must be firmly rolled with a minimum 28 lb. hand roller to ensure full contact and adhesion. For Dual Pro and Tile Pro, align the edge of the top sheet to the end of the glue pattern (the sheet will overlap the fabricj. Exterior Research and Design, LLC. Evaluation Report P12060.02.09-11111 Certificate of Authorization #9503 FL5259-R16 Revision 11: 08/17/2012 Page 8 of 10 \l TRINITYIERD a � x fA katil 1 Y� g_6 9 A View of Ovelap Seam of Dual Pro and Tile Pro 6.4.2.3 All over -fabric and over -granule end -laps shall have a 6-inch wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Polystick TU Plus Tile Underlayment Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Electrometric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic, applied in between the application of the lap. 6.4.2.4 Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details 6.4.2.5 Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Polystick TU Plus Tile Underlayment Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic to the area in need of repair, followed by a minimum 6 x 6 inch patch of the Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be installed in a water shedding manner. 6.4.2.6 All Polystick membranes shall be .installed to ensure full contact with approved substrates. Polyglass requires a minimum of 40-lb weighted -roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied for the field membrane. Hand rollers are acceptable for rolling of patches, laps (min. 28 lb roller) or small areas of the roof that are not accessible to a large roller or broom. 6.4.3 For tile applications (not allowed for Polystick IR-Xe): 6.4.3.1 Reference is made to Section 6.4.2 herein in conjunction with FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein, using the instructions noted above as a guideline. 6.4.3.2 For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the tile. Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1111 Certificate of Authorization #9503 FL5259-R16 Revision 11: 08/17/2012 Page 9 of 10 F'1�0 TRINITY 11 ERD 6.5 Elastoflex S613 or S6G FR: 6.5.1 Elastoflex S6G or S6G FR shall be installed in compliance with current Polyglass published installation requirements. For use in nail -on tile applications, reference is made to FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein. 6.5.2 Elastoflex S6G or S6G FR shall be fully asphalt -applied to the substrates noted in Section 5.5. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, and off set end -laps minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge. 6.6 Polyflex G or G FR: 6.6.1 Polyflex G or G FR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications, reference is made FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein. 6.6.2 Polyflex G or G FR shall be fully asphalt -applied to the substrates noted in Section 5.5. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, and off set end -laps minimum 3 feet from course to course. Side and end laps shall be fully heat -welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap edge. 6.7 Tile Staging: 6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to Polyglass published requirements for tile staging.. 6.7.2 Battens and/or Counter -battens, as required by the the manufacturer and FRSA/TRI 07320/8- 05 must be used on all roof slopes greater than 7:12. For roof slopes in excess of 61/4:12, precautions should be taken, such as the use of battens, to prevent tile sliding during the loading process. 6.7.3 For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the tile. 6.7.4 The minimum cure time after installation of self -adhering membranes and before loading of roofing tiles is forty-eight (48) hours. 7. LABELING: i Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. S. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL, LLC — QUA9625; (314) 578-3406; k.chancellor@us.ul.com - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R11 Certificate of Authorization #9503 FL5259-R16 Revision 11: 08/17/2012 Page 10 of 10