HomeMy WebLinkAboutSUBMITTED PAPERSDATE:
FEES
IU.,1 ( - n I RECEIPT #: - I Permit #:
1. Location/Site Address:
Planning & Development Services Department
Building & Code Regulation Division
2300 Virginia Avenue
Ft. Pierce, FL 34982-5652 CANN"O
Tel. 772-462-1553 St Q y
APPLICATION FOR ROOF PERMIT `ucie Count
SEE REVERSE SIDE FOR INSTRUCTIONS
-l[�77� 1�iillf3 _npll Awfii0 �-�V __ �-L 3yg51
2. Parcel ID Number: 14. `d�4
Office Use
Only
Section
Township
Range
Map Page
I Zoning
Land Use
I Initials
3. Description of Project or Work Activity:
v
4. Total Roof Area (square feet): 2-4Q� 5. Roof Pitch:
6.. Type of Roof. ><] Fiberglass Shingle [ ] Concrete Roof Tile
[ ] Tar & Gravel [ ] Modified Bitumen
01
[ ] Wood Shake / Shingle
[ ] Other
[ ] Product Approval required for all types of Roofing Material (2 Sets)
] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product
Approval. attached
** Roof Mitigation per F.S. 553.844 will be required.
7. Owner Information 8. Contractor Information
Name: abi lent WAf rsw
Address: 54bZ Y)111QJr)W Aft
City:., F&P i tfeQ State: FL
Zip:,2M5k Phone: D�
FL Reg/Cert #:
County Cert #: o V � f 7
Business Name: Nr,C,�ri �trvi S ln�
Cell Phone:(1 I •���t
9. Value of Construction: $.
"Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval.
CONTRACTORIOWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be
done in co pliance with all applicable laws regulating construction and'zoning:
JC)I�,r) � s
PRINT QUALIFIERS/OWNERS NAME S ATURE OF QUALIFIER/OWNER
STATE OF FLORIDA, COUNTY OF zv� (-
ACKNOWLEDGED BEFORE METHIS 13�DAY OF T V Q V� 20j, BY g 1 kf4l
WHO IS PERSONALLY KNOWN�I O ME OR HAS PRODUCED
SIGNATURE OF NOTARY TYPE OR PRINT NAME OF NOTARY t
COMMISSION NUMBER
NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEME
FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FIN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
Revised 4/26/2010
-
ECCE�xPs'`1-R-E
TION
f YOUR PAYING TWICE
YOUR LENDER OR
INSTRUCTIONS
Please complete all information in the space provided. All information must be printed (use black or blue ink
only) or typed. This roof permit application is to be used only for those activities that are not otherwise included
under a primary building permit. This application may not be used for any activity. that includes structural
alteration. Building activities involving structural alteration, in addition to the roof work, must be permitted
through the regular building permit review process. The information to be provided with this application
includes:
1. Location/Site Address
2. Parcel ID Number
3. Description of Project or Work Activity
4. Total Roof Area
5. Type of Roof
6. Owner Information
7. Contractor Information
8. Value of Construction
Indicate the street address or general location of the
property where the building activity is taking place.
Indicate the tax identification number of the property where
the building activity is taking place.
Completely describe the building activity to take place.
Please indicate if tear -off or shingle over shingle etc.
Indicate total roof area to be affected by this permit. Also
indicate the pitch of the roof, expressed as a standard ratio
of run rise.
Indicate the type of roof being repaired or resurfaced.
Indicate the name and address of the owner of the property
on which building activity is taking place.
Indicate the State of Florida registration number (if
applicable), St. Lucie County contractor license number and
the name of the business doing the work.
Indicate the total value of the work to take place. Total cost
of construction includes all material and labor costs
associated with the building/construction activity.
Construction value is used to determine the permit fee. St.
Lucie County reserves the right to question and/or modify
the indicated value of construction if it is demonstrated that
the submitted figures are not consistent with similar types
of construction.
This application can be submitted to St. Lucie County Building and Zoning, 2300 Virginia Avenue, Fort Pierce,
FL 34982. All permit applications must be filled out completely before submission. No applications will be
accepted for processing after 4:30 P.M. For assistance in completing this application, please call (772)
462-1553, during regular office hours (8:00 AM - 5:00 PM), Monday through Friday.
Upon issuance of this permit, required inspections can be scheduled by calling (772) 462-1261.
St Lucie County Roof Permit Application rev. 3/1/2009
JOSEPH E. SMITH, CLERK OF THE CIRCUIT COURT — SAINT LUCIE COUNTY
FILE # 3785192 OR BOO 169 PAGE 341, Recorded 01/02/2013 a -1:16 AM
i
Permit No.
NOTICE OF�,CQMMEN,C{EMENT G
Tax Folb No. tt.7� �' �� `t •�� ".� '!
State of pmWa County of St. Lude
Tiro undersigned h ereby gives notice that Improvement will be made to rsrtsin real property, and in accordance with Chapter 713, Florida Statutes,
the following k1for rnation is provided In this Notk a of Commencement.
General dasa d lmpova W-2b►MV - A
Owaer loft a Mosm dort If theJJJaLm contracted for the Improvement:
Name _
Address4 But,
Interest In prop�`f
Name and fee simple titleholder (If different from Owner listed above):
Cooursoes
Contractor
sooty (d oppl , a copy of the payment bond Is attacited): Amount of bond: S
Name and addre Phone number:
Laadar Names Phone Number.
Lendses address:
Peraoas wkNk a Steme alponder deskmaW by OvineraPoo wlmm notices or other documents stay be sawed as provided by section
ZUAX1) (a)7., F orlda steatem
Name: Phone Number.
Address:
In addition to hin self or herself, Owner designates of to receive a copy of the
Lienoes Notice a pralded in Section 713.UM (b), Florida Statutes.
Phone number Mesa" a er►tllY designated by owner.
Expiration date notice of comnencament: (the expiration date may not be before the completion of oxwostructbn and final payment to the
oontracor, I ba 1 year from the date of ram img unless a different date Is specified)
WARNWGTO ER: ANY PAYMENTS MADEBYTHEOWNERAFTERTHEEXPIRATIONOFTHENOTICEOFCOMMENCEMENT ARE CONSIDERED
IMPROPER PA NTS UNDER WAFTER 713, PART 1, SECTION 7]313, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS YOUR PROPERTY. A NOTICE OF T MUST � � �� ONT�� � � THE F1IST
INSPECTION. IF INTENDTOOBTAINFINANCING,00NSULTWLTHYOURLENDERORANATTORNEYBEFORECOMMENaNGWORKOR
RECORDING YOU I NOTICE OF COMMENCEMENT.
Under penalty of perjury, I declare that I haw read the foregoing notice of commencement and that the facts stared therein am tree to the bat of
:mv�know(edee, essee, or Owners or Lessees Authorized Off1cer1Dkeaar/Ps1tner/Manager
(Slputory'sli )
The foregoingI twas acknowledged beforemethls_L(.—dayof V &, 2019-
BY r as //entsrrl t /` for
Name o ^ .JOSS Type of authority (04• officer, trustee) Party on behalf of whom irtstrurnent was executed
6 krownl%r produced Identification_
of N tary P-State of Florida) maums
Yicationproduced
(Pent, Type, or Stamp Commissioned Name ref oil 10i,
STATE OF FLORIDA
ST, LUCIE CONTY
T11161S TO CERTIFY THAT TWIQ IC A
l — 1P.gc 2 of 2
2013-01-03 1 B:24: 40 (GMT)
17727940409 From: Ma11— Cola
amp
C6UNTY .
F L O R I D A
Re: Permit # I so I
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34982
772-462-2165 or 772-462-2172
Fax: 772-462-6443
ROOF INSPECTION AFFIDAVIT
I On" �.L;.S 5 ,licensed as a(9 Contract */Engineer/Architect
(Please print name & circle license type) *FS4 Ina Inspector
*General, Building, Residential or Roofing Contractor or any individual certified under 468 F.S. to make such an inspection.
On or about I did personally inspect the roof deck nailing
( ate)
work at:.Bqw
(44 site address)
Based upon that examination I have determined the installation was done according to the Hurricane
Mitigation Retrofit Manual (Based on 553.844 F.S.)
Signature and Seal
License #
STATE OF F OR
COUNTY
S�wo q-� and sub scr�bed before me this _ day of �.><1 Tf'J 20�
%S� . Who is personally Imown to me or who has produced
as identification. " %
Notary Public, State Hof orid�
Signature of Notary:,
Commission Number:
En 01/19/2011
(Sea()
a. ..Y�.r'^'�ls ti.I 1w! �r"+w."— '•+� �a 10/' 4�f
1
fCp.N34elh: 4 f3'.=t�'.' T V.
SiA'S•a?A.tif.tiF ccc a:��:F�
(772) 794-0408 Fax: (772) 794-0409
To: Peterson Residence June 12, 2012
Location: 5400 Killarney Avenue & ), 0 OQP ,
Fort Pierce, FI 34951 ���% r/ 1
Dimensional Shingle Re -Roof
➢ Obtain a Re -Roofing Permit. o PY
➢ Remove old roof down to wood decking. FILL,.
➢ HannaBd is responsible for the removal and hauling of old roof debris.
➢ Inspect all wood decking or sheeting for any water damage.
➢ Any damaged plywood decking replacement is an additional charge of $2.00 per square foot and
replacement of soffit, fascia and/or sub -fascia $6.00 per foot over the estimated price. (Does not
include any structural framing.) (2) sheets of wood replacement are included in contract.
➢ Re -nail decking to meet current Florida Building Codes. (using 8d full ring -shank fasteners six inches
on center.
➢ The entire wood roof deck shall be covered with 30# felt paper with the use of tin tags.
➢ Install 210' of 2x2 inch eave metal to be mechanically fastened to code with ring -shank fasteners.
➢ Install 53' of valley.
➢ Install (5) new lead plumbing boots (1) electrical mast.
➢ Install 175' shingle "High Ridge" to replace what is existing.
➢ Removal and re -installation of 108' of gutter around home is included in our contract.
➢ Install a 40yr True Def (Harbor Blue) Dimensional roof system over entire pitched roof surface to match
what is existing, to be mechanically fastened to Florida building code and/or manufacture's
specifications. with ring -shank fasteners.
Line Item: Add an additional $325.00 to contract price for the use of a secondary water barrier in lieu of 30#
felt paper underlayment.
Five year warranty on workmanship, guaranteed, effective on final invoice date.
All quotes are good for 15 days upon receipt After 15 days, quote will be reevaluated to include any price changes to supplies and materials needed to
perform the above stated description. Any extra roofing systems found while performing a reroof, will bean additional charge of $50.00 per every 100
square feet. All material is guaranteed to be as specified. All work to be completed in a workmanlike manner according to standard practices. Any
alteration or deviation from above specifications involving extra cost will be executed only upon written orders, and will become an extra charge over and
above the estimate. All agreements are contingent upon strikes, accidents or delays beyond our control. Owner is to carry fire, tornado and other
necessary insurance. Our workers are fully covered by workmen's compensation insurance. Not responsible for existing wall paint, gutters,
landscaping, sidewalks and irrigation.
Total for Shingle Re -Roof: $8,385.00 Payment Methods:
Payments to be disbursed as follows: ❑cash
25% Down to Start - $2,096.25 ❑Check/Money Order
50% In Mid Process - $4,192.50 ❑Mastercard ❑Visa
25% Upon Completion - $2,096.25
Complete if Using Credit/Debit Card: Name as Appears on Card
Account #
3 Digit Security Code
Amount Authorized $ Signature of Card Holder
Contractor
Property Owner
Exp Date
Date /2
Date��-
Florida Building Code Online
Page 1 of 2
FL #
FL10124-R7
Application Type
Editorial Change
Code Version
2010
Application Status
Approved
Comments
Archived
Product Manufacturer GAF
Address/Phone/Email 1361 Alps Road
Wayne, NJ 07470
(973)872-4421
Iindareith@trinityerd.com
Authorized Signature Beth McSorley
Iindareith@trinityerd.com
Technical Representative Beth McSorley
Address/Phone/Email 1361 Alps Road - Bldg 11-1
Wayne, NJ 07470
(973)872-4421
BMcSorley@gaf.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who Robert Nieminen
developed the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 07/31/2013
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FL10124 R7 COI Trinity ERD CI - Nleminen.odf
Referenced Standard and Year (of Standard) Standard
Year
ASTM D3161 (Class F)
2006
ASTM D3462
2007
ASTM D7158 (Class H)
2007
TAS 107
1995
Equivalence of Product Standards
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?paratn=wGEVXQwtDquracBeVCbdMQ... 1 /2/2013
Florida Building Code Online --
Page 2 of 2
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Date Revised
Method 1 Option D
04/04/2012
04/25/2012
04/29/2012
06/11/2012
10/22/2012
................................ .
Summary of Products
FL #
Model, Number or Name IlDescription
10124.1
GAF Asphalt Roof Shingles
Fiberglass reinforced 3-tab, laminated, 5-tab and j
hip/ridge asphalt shingles j
Limits of Use
Approved for use in HVHZ: No
Installation Instructions
FL10124 R7 II er041912FINAL GAF Asphalt
Shingles FL10124-R7.Ddf
Verified By: Robert Nieminen PE-59166
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: Refer to ER, Section 5.
Evaluation Reports
FL10124 R7 AE er041912FINAL GAF Asphalt
Shingles FL1.0124-R7.odf
Created by Independent Third Party: Yes
sack Next
Contact Us :: 1940 North Monroe Street, Tallahassee Fl- 32399 Phone: 850-487-1824
The State of Florida is an WEED employer. Cooyriaht 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not
send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395.
*Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department
with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public
record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.
To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
z't hsci
12
Sccaritv�ssTs�tc-
x
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquracBeVCbdMQ... 1 /2/2013
Q0_rFuN1TYJ'ERD
EVALUATION REPORT
GAF
1361 Alps Road, Building,7-3
Wayne, NJ 07470
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX:(203) 262-9243
Evaluation Report 01506.01.08-119
FL10124-R7
Date of Issuance: 01/03/2008
Revision 9: 04/19/2012
SCOPE:
This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing
the use of construction materials in the State of Florida. The documentation submitted has been
reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and
Florida Building Code, Residential Volume. The products described herein have been designed to
comply with the 2010 Florida Building Code sections noted herein.
DESCRIPTION: GAF Asphalt Roof Shingles
LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality
Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)
changes, the referenced Quality Assurance documentation changes, or provisions of the Code that
relate to the product change. Acceptance of this Evaluation Report by the named client constitutes
agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality
Assurance documentation changes. TrinitylERD requires a complete review of this Evaluation
Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may
be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it
shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by
the manufacturer or its distributors and shall be available for inspection at the job site at the
request of the Building Official.
This Evaluation Report consists of pages 1 through 4.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized
by Robert Nieminen, P.E. on 04/19/2012
This does not serve as an electronically signed
document. Signed, sealed hardcopies have been
transmitted to the Product Approval Administrator and
to the named client
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. TrinitylERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which
the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved In the approval process of the
product.
a T .ERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Asphalt Shingles
Compliance Statement: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated
compliance with the following sections of the Florida Building Code and Florida Building Code,
Residential Volume through testing in accordance with the following Standards. Compliance is subject
to the Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1507.2.5, R905.2.4
Physical Properties
ASTM D3462
2007
1507.2.7.1, R905.2.6.1
Wind Resistance
ASTM D3161, Class F
2006
1507.2.7.1, R905.2.6.1
Wind Resistance
ASTM D7158, Class H
2O07
1507.2.7.1, R905.2.6.1
Wind Resistance
TAS 107
1995
3. REFERENCES:
Entity
Examination
Reference
Date
GAF (PDM 1915)
Letter of Equivalency
Seal -A -Ridge Impact Resistant IR
01/13/2012
PRI(TST 5878)
ASTM D3462
GAF-059-02-01
09/02/2004
PRI (TST 5878)
ASTM D3462
GAF-080-02-01
05/25/2005
UL (TST 1740)
ASTM D3462
93NK6295
11/29/1993
UL (TST 1740)
ASTM D3462
99NK43835
01/12/2000
UL (TST 1740)
TAS 107
94NK9632
03/29/2000
UL(TST.1740)
ASTM D3462
01NK06632
02/02/2001
UL (TST 1740)
ASTM. D3161, TAS 107
01NK9226
05/21/2001
UL (-TST 1740)
ASTM D3161
OINK37122
12/18/2001
UL (TST 1740)
ASTM D3462
OINK37122
12/19/2001
UL (TST 1740)
ASTM D3161, TAS 107
02NK12980
04/10/2002
UL (TST 1740)
ASTM D3161, TAS 107
02NK30871_
09/09/2002
UL (TST 1740)
ASTM D3161
03CA5367
03/11/2003
UL (TST 1740)
ASTM D3462
03NK26444
10/17/2003
UL (TST 1740)
ASTM D3462
04NK13850
06/07/2004
UL (TST 1740)
ASTM D3161
04NK13850
06/23/2004
UL (TST 1740)
ASTM D3161
04NK30546
03/10/2005
UL (TST 1740)
ASTM D3462
04NK22009
05/06/2005
UL(TST 1740)
ASTM D3161
04NK22009
05/09/2005
UL (TST 1740)
ASTM D3462
05NK27924
02/10/2006
UL (TST 1740)
ASTM D3161
05NK27924
02/11/2006
UL (TST 1740)
ASTM D3161,D3462
06CA18077
06/05/2006
UL (TST 1740)
ASTM D3161, D3462
06CA18074
06/16/2006
UL (TST 1740)
ASTM D3161, D3462
06CA35251
10/18/2006
UL (TST 1740)
ASTM D3462
06CA31603
12/01/2006
UL (TST 1740)
ASTM 133161,133462
06CA41095
12/27/2006
UL (TST 1740)
ASTM D3161
07NK05228
03/13/2007
UL (TST 1740)
ASTM D3161
06CA31611
04/04/2007
UL (TST 1740)
ASTM D3161
06CA61148
04/09/2007
UL (TST 1740)
ASTM D3161, D3462
07CA31742
11/08/2007
UL (TST 1740)
ASTM D3161, D7158, D3462
08CA06100
03/13/2008
UL (TST 1740)
ASTM D3161, D3462
07CA55908
04/01/2008
UL (TST 1740)
ASTM D3161,133462
09CA10592
03/26/2009
UL (TST 1740)
ASTM D3161, D3462
09CA06856
05/15/2009
UL (TST 1740)
ASTM D3161, D7158, D3462
09NK06647
08/01/2009
UL (TST 1740)
ASTM D3161, D7158, D3462
09CA27281
08/27/2009
UL (TST 1740)
ASTM D3161, D7158, D3462
IOCA35554
03/05/2010
UL (TST 1740)
ASTM D3161, D7158, D3462
10CA13686
05/15/2010
UL (TST 1740)
ASTM D3462
IOCA07264
05/27/2010
UL(TST 1740)
ASTM D3462
IOCA11953
10/29/2010
UL (TST 1740)
ASTM D3161, D7158, D3462
1ONK11951
10/30/2010
UL (TST 1740)
ASTM D3161, D7158, D3462
IONK12070
11/04/2010
UL (TST 1740)
ASTM D3161, D7158, D3462
08CA06100
01/30/2010
UL (TST 1740)
ASTM D3161, D7158, D3462
10CA53934
03/31/2011
UL (TST 1740)
ASTM D3161, D7158, D3462
11CA48924
10/22/2011
Exterior Research and Design, LLC. Evaluation Report 01506.01.08-1117
Certificate of Authorization #9503 FL10124-R7
Revision 9: 04/19/2012
Page 2 of 4
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL, LLC. (QUA 9625)
UL, LLC. (QUA 9625)
4. PRODUCT DESCRIPTION:
ASTM D3161, D7158, D3462
ASTM D3161, D7158, D3462
ASTM D3161, D7158, D3462
Quality Control
Quality Control
F"<)
`J I RINIIY I ERD
IICA47919 12/03/2011
11CA48408 12/08/2011
11CA48725 12/09/2011
Inspection Report, File No. R21 02/06/2012
R3915 Current
4.1 Marquis WeatherMax, Royal Sovereign and Sentinel are a fiberglass reinforced, 3-tab asphalt
roof shingles.
4.2 Camelot, Camelot II / Camelot 30, Capstone, Country Mansion, Country Mansion II, Grand
Canyon, Grand Sequoia, Grand Slate, Grand Slate II, Monaco, Timberline American Harvest,
Timberline ArmorShield II, Timberline Natural Shadow, Timberline Natural Shadow Arctic White,
Timberline HD / Timberline Prestique 30, Timberline Prestique 40 / Timberline Cool Series,
Timberline Ultra HD / Timberline Prestique Lifetime, Timberline Majestic / Timberline Majestic 30
and Woodland are fiberglass reinforced, laminated asphalt roof shingles.
4.3 Slateline is a fiberglass reinforced, 5-tab asphalt roof shingle.
4.4 Seal -A -Ridge, Seal -A -Ridge Armorshield, Seal -A -Ridge Impact Resistant IR, Ridglass 8, Ridglass
10, Ridglass 12 and Timbertex Hip and Ridge are fiberglass reinforced, hip and ridge asphalt
roof shingles.
4.5 ProStart Starter Strip Shingles and WeatherBlock& Starter Strip Shingles are a starter strips for
asphalt roof shingles.
S. LIMITATIONS:
5.1 This Evaluation Report is not for use in the HVHZ.
5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing
Materials Directory for fire ratings of this product.
5.3 Wind Classification:
5.3.1 All GAF shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are
acceptable for us in all wind zones up to Vasd = 150 mph (V,it. = 194 mph). Refer to Section 6
for installation requirements to meet this wind rating.
5.3.2 All GAF hip & ridge shingles noted herein are. Classified in accordance with FBC Tables
1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for
us in all wind zones up to Vasd = 150 mph (Vuit = 194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
5.3.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60
feet or less. Calculations by a qualified design professional are required for conditions outside
these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.4 All products in the roof assembly shall have quality assurance audit in accordance with the
Florida Building Code and F.A.C. Rule 9N-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product
Approval, or be Locally Approved per Rule 9N-3, per FBC Sections 1507.2.3, 1507.2.4 or
R905.2.3.
6.2 Starter Shingles:
Exterior Research and Design, LLC. Evaluation Report 01506.01.08-1117
Certificate of Authorization #9503 FL10124-R7
Revision 9: 04/19/2012
Page 3 of 4
QT INITY I ERD
6.2.1 Installation of ProStart Starter Strip Shingles and WeatherBlocker Starter Strip Shingles shall
comply with the manufacturer's current published instructions.
6.3 Asphalt Shingles:
6.3.1 Installation of asphalt shingles shall comply with the manufacturer's current published
instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2
or R905.2, with the following exceptions:
➢ Camelot, Camelot II / Camelot 30, Grand Slate II, Country Mansion II, Monaco and
Woodland require minimum five (5) fasteners per shingle
6.3.2 Fasteners shall be in accordance with manufacturer's published requirements, but not less than
FBC 1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of
fastening are required. Contact the shingle manufacturer for details.
6.4 Hip & Ridge Shingles:
6.4.1 Installation of Ridglass 8, Ridglass 10 and Ridglass 12 asphalt shingles shall comply with the
manufacturer's current published instructions with a minimum two (2) nails per side [total of
four (4) nails per shingle] and asphalt roofing cement.
6.4.2 Installation of Seal -A -Ridge, Seal -A -Ridge Armorshield and Seal -A -Ridge Impact Resistant IR
asphalt shingles shall comply with the manufacturer's current published instructions with a
minimum two (2) nails per shingle.
6.4.3 Installation of Timbertex Hip and Ridge asphalt shingles shall comply with the manufacturer's
current published instructions with a minimum two (2) nails per shingle and beads of
Sonneborn NPi Gun Grade Polyurethane Sealant or Henkel PL Roofing and Flashing Sealant.
6.4.4 Fasteners shall be in accordance with the manufacturer's published requirements, but not less
than FBC 1507.2.6 or R905.2.5. Staples are not permitted.
7. LABELING:
7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo
of the Accredited Quality Assurance Agency noted herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications
detailed in FBC Table 1507.2.7.1 / R905.2.6.1.
S. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the
installation of this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule
9N-3 QA requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC — QUA9625; (847) 664-3281
- END OF EVALUATION REPORT -
Exterior Research and Design, LLC. Evaluation Report 01506.01.08-117
Certificate of Authorization #9503 FL10124-R7
Revision 9: 04/19/2012
Page 4 of 4
FL #
FL5259-R16
Application Type
Revision
Code Version
2010
Application Status
Approved
Comments
Archived
Product Manufacturer POLYGLASS USA
Address/Phone/Email 150 Lyon Drive
Fernley, NV 89408
(570)384-1230 Ext242
jaklns@polyglass.com
Authorized Signature James Akins
jaklns@polyglass.com
Technical Representative Steve Wadding
Address/Phone/Email 150 Lyon Drive
Fernley, NV 98408
(602)363-7139
stevew@polyglass.com
Quality Assurance Representative James Akins
Address/Phone/Email 555 Oakridge Road
Humboldt Industrial Pkwy
Hazleton, PA 18201
(800) 894-4563
jaklns@polyglass.com
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who Robert Nleminen
developed the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 08/08/2015
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FL5259 R16 COI Trinity ERD CI - Nieminen.odf
Referenced Standard and Year (of Standard) Standard
Year
ASTM D1970
2001
ASTM D226
2006
ASTM D6164
2005
http://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgvbSgAaZp3 Crk2... 1 /2/2013
Florida Building Code Online,—,
Page 2 of 2
f ,
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Date Revised
ASTM D6222
2002
ASTM G154
2005
ASTM G155
2005
FM 4474
2004
FRSA/TRI07320
2005
TAS 103
1995
Method 1 Option D
08/17/2012
08/21/2012
08/27/2012
10/09/2012
12/07/2012
Summary of Products
FL #
Model, Number or
Description j
Name
j
5259.1
Polyglass Roof
Roofing underlayments
Underlayments
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL5259 R16 II er081712FINAL POLYGLASS UNDERLAYMENTS FL5259-
R16.odf
Approved for use outside
HVHZ: Yes
Verified By: Robert Nieminen PE-59166
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-622.5
Evaluation Reports
Other: 1.) The design pressure in this
FL5259 R16 AE er081712FINAL POLYGLASS UNDERLAYMENTS FL5259-
R16"Ddf
application relates to one particular
underlayment system for use under
Created by Independent Third Party: Yes
foam -on tile systems. Refer to ER
Section 5.5.2 for other systems and
maximum design pressures. 2.) Refer
to ER Section 5 for other limits of use.
Back Next
Contact Us :: 1940 North Monroe Street Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. Copyright 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not
send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395.
*Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department
with an email address If they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public
record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.
To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
WeRhtcX
�Y:Cpt"i M£"e fILSCs
A
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?paratn=wGEVXQwtDgvbSgAaZp3 Crk2... 1 /2/2013
. " . - / "--\ 1 11 �-1 4 Q h tv"
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT #13
�TRINIIY ERD OXFORD, CT 06478
PHONE: (203) 262 9245
FAX: (203) 262-9243
EVALUATION REPORT
Polyglass USA, Inc. Evaluation Report P12060.02.09-1111
150 Lyon Drive FL5259-1116
Fernley, NV 98408 Date of Issuance: 02/24/2009
Revision 11: 08/17/2012
SCOPE:
This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing
the use' of construction materials in the State of Florida. The documentation submitted has been
reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and
Florida Building .Code, Residential Volume. The products described herein have been designed to
comply with the 2010 Florida Building Code sections noted herein.
DESCRIPTION: Polyglass Roof Underlayments
LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality
Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)
changes, the referenced Quality Assurance documentation changes, or provisions of the Code that
relate to the product change. Acceptance of this Evaluation Report by the named client constitutes
agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality
Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation
Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinityJERD Evaluated" may
be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it
shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by
the manufacturer or its distributors and shall be available for inspection at the job site at the
request of the Building Official.
This Evaluation Report consists of pages 1 through 10.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized
by Robert Nieminen, P.E. on 08/17/2012
This does not serve as an electronically signed
document. Signed, sealed hardcopies have been
transmitted to the Product Approval Administrator and
to the named client
CERTIFICATION OF INDEPENDENCE:
1. TrinityJERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity) ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which
the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity Involved in the approval process of the
product.
P�RJNITY If ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have
demonstrated compliance with the following sections of the Florida Building Code through testing in
accordance with the following Standards. Compliance is subject to the Installation Requirements and
Limitations / Conditions of Use set forth herein.
2. , STANDARDS:
Section
Property
Standard
Year
1507.2.3, 1507.3.3, 1507.5.3,
1507.7.3 1507.8.3 1507.9.3
Physical Properties
ASTM D226
2006
1507.2.4, 1507.2.9.2, 1507.3.3,
1507.5.3
Physical Properties
ASTM D1970
2001
1507.11.2
Physical Properties
ASTM D6164
2005
1507.11.2
Physical Properties
ASTM D6222
2002
1504.6
Accelerated Weathering
ASTM G154'
2005
1504.6
Accelerated Weathering
ASTM G155
2005
1504.3.1
Wind Uplift
FM 4474
2004
1507.3.3
Installation Practice
FRSA/TRI 07320
2005
1523.6.5.2.1
Physical Properties
TAS 103
1995
3. REFERENCES:
Entity
Examination
Reference
Date
FM Approvals (TST 1867)
Wind Uplift
3004091
01/12/2000
PRI (TST 5878)
Physical Properties
PRIO1111
04/08/2002
PRI (TST 5878)
Physical Properties
PUSA-005-02-01
01/31/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-01
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-02
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-03
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-018-02-01
07/14/2003
PRI (TST 5878)
Physical Properties
PUSA-028-02-01
07/13/2005
PRI (TST 5878)
Physical Properties
PUSA-033-02-01
01/12/2006
PRI (TST 5878)
Physical Properties
PUSA-035-02-01
09/29/2006
PRI (TST 5878)
Physical Properties
PUSA-055-02-02
12/10/2007
PRI (TST 5878)
Physical Properties
PUSA-061-02-02
01/28/2008
PRI (TST 5878)
Physical Properties
PUSA-076-02-01
02/22/2008
PRI (TST 5878)
Physical Properties
PUSA-083-02-01
04/14/2008
PRI (TST 5878)
Physical Properties
PUSA-088-02-01
07/29/2009
MTI (TST 2508)
Physical Properties
JX20H7A
04/01/2008
MTI (TST 2508)
Physical Properties
RX14E8A
01/29/2009
ERD (TST 6049)
Physical Properties
11752.09.99-1
02/08/2000
ERD (TST 6049)
Wind Uplift
11776.06.02
01/16/2003
ERD (TST 6049)
Physical Properties
02200.07.03
07/14/2003
ERD (TST 6049)
Wind Uplift
P1740.01.07
01/04/2007
ERD (TST 6049)
Physical Properties
P5110.04.07-1
04/11/2007
ERD (TST 6049)
Wind Uplift
P9260.03.08
03/21/2008
ERD (TST 6049)
Physical Properties
P13450.08.09
08/13/2009
ERD (TST 6049)
Wind Uplift
P30540.11.09-111
11/30/2009
ERD (TST 6049)
Physical Properties
P33360.06.10
06/25/2010
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R11
Certificate of Authorization #9503 FL5259-R16
Revision 11: 08/17/2012
Page 2 of 10
r ,
TRINITY I ERID
Entity Examination Reference Date
ERD (TST 6049) Physical Properties P33370.03.11 03/02/2011
ERD (TST 6049) Physical Properties P33370.04.11 04/26/2011
ERD (TST 6049) Physical Properties P40390.08.12-1 08/06/2012
ERD (TST 6049) Physical Properties P40390.08.12-2 08/07/2012
ICC-ES (EVL 2396) IBC Compliance ESR-1697 11/01/2011
Miami -Dade (CER 1592) HVHZ Compliance NOA Current
Polyglass USA Manufacturing Affidavit Products Current 02/18/2009
Polyglass USA P/L Affidavit Mule -Hide Cross Ltg 03/01/2008
Polyglass USA Materials Affidavit Polystick SA Compound 08/18/2011
UL, LLC. (QUA9625) Quality Control Service Confirmation Exp. 08/08/2015
4. PRODUCT DESCRIPTION:
4.1 Mechanically Fastened Underlavments:
4.1.1 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet.
4.1.2 Elastobase P is a polyester -reinforced, SBS modified bitumen base sheet.
4.2 Self -Adhering Underlavments:
4.2.1 Polystick MTS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber
reinforced, surfaced with polyolefinic film surface; meets ASTM D1970 and TAS 103.
4.2.2 Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass
fiber reinforced, with an aggregate surface; meets ASTM D1970.
4.2.3 Polystick TU is a nominal 100-mil thick rubberized asphalt waterproofing membrane, glass fiber
reinforced, with a granular surface; meets ASTM D1970 and TAS 103.
4.2.4 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane, glass
fiber reinforced, with a polyester fabric surface; meets ASTM D1970 and TAS 103.
4.2.5 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-
fiber/polyester reinforced, with a granular surface; meets ASTM D1970 and TAS 103.
4.2.6 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a
170 g/m2 polyester fabric surface; meets TAS 103.
4.2.7 Polyflex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet
.(FR) are a polyester reinforced, APP modified bitumen cap sheets.
4.2.8 Dual ProTM is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane,
fiberglass reinforced, with a polyester fabric surface.
4.2.9 Tile ProT"' is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane,
fiberglass reinforced, with a polyester fabric surface.
4'.3 Mechanically Fastened and/or Bonded Underlavments:
4.3.1 Elastoflex S6G and Elastoflex S6G FR are polyester reinforced, SBS modified bitumen cap
sheets.
4.3.2 Polyflex G and Polyflex G FR are polyester reinforced, APP modified bitumen cap sheets.
S. LIMITATIONS:
5.1 This Evaluation Report is not for use in the HVHZ..
5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing
Materials Directory for fire ratings of this product.
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R11
Certificate of Authorization #9503 FL5259-Ri6
Revision 11: 08/17/2012
Page 3of10
UD
RINITY i ERD.
5.3 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is
specifically referenced within FBC approval documents. If not listed, a request may be made
to the AH] for approval based on this evaluation combined with supporting data for the
prepared roof covering.
5.4 Allowable roof covers applied atop the underla ments are as follows:
Table 1: Roof Cover Options
Underlayment
Asphalt
Nail -On Tile
Foam -On
Metal
Wood
Shakes &
Slate
Shingles
Tile
Shingles
Elastobase
Yes
Yes
No
Yes
Yes
Yes
Elastobase P
Yes
Yes
No
Yes
Yes
Yes
Polystick MTS
Yes
Yes
No
Yes
Yes
Yes
Polystick IR-Xe
Yes
No
No
No
Yes
Yes
Polystick TU
Yes
Yes
Yes
No
Yes
Yes
See 5.4.1
Polystick TU P
Yes
Yes
See es
5.Polystick
No
Yes
Yes
TU Plus
Yes
Yes
es
Yes
Yes
Yes
See
5.Polystick
TU Max
No
Yes
Yes
No
No
No
See 5 4.1
Dual Pro
Yes
Yes
No
Yes
Yes
Yes
Tile Pro
Yes
Yes
See es
5.Elastoflex
Yes
Yes
Yes
S6G or S6G FR
Yes
Yes
No
No
Yes
Yes
Polyflex G or G FR
Yes
Yes
See es
5.Polyflex
No
Yes
Yes
SAP or SAP FR
Yes
Yes
See es
5.Mule-Hide
No
Yes
Yes
SA-APP Cap Sheet
Yes
Yes
Yes
No
Yes
Yes
or SA-APP Cap Sheet (FR)
See 5.4.1
5.4.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives unless tensile
adhesion / long term aging data from an accredited testing laboratory is provided.
➢ Polyfoam PolyPro AH160: Polystick TU, Polystick TU P, Polystick TU Plus, Polyflex G,
Polyflex G FR, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -
Hide SA-APP Cap Sheet (FR) or Tile Pro.
➢ 3MTm 2-Component Roof Tile Adhesive AH-160: Polystick TU Max
➢ Dow TileBond: Polystick TU P, Polystick TU Plus, Polyflex SAP or Tile Pro
5.4.2 For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the
tile.
5.4.3 A 2-ply underlayment system, consisting of Polystick MTS followed by Polystick MTS, TU, TU
P, TU Plus or TU Max, or Polyflex SAP is allowable for use under mechanically attached
prepared roof systems. This is not a requirement, but is allowable if a 2-ply underlayment
system is desired.
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1111
Certificate of Authorization #9503 FL5259-1116
Revision 11: 08/17/2012
Page 4 of 10
5.5 Allowable substrates are noted below:
5.5.1 Direct -Bond to Deck:
Polystick, Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP
Cap Sheet (FR) self -adhered to:
➢ New untreated plywood;
➢ ASTM D41 primed new untreated plywood;
➢ Existing plywood;
➢ ASTM D41 primed existing plywood;
➢ ASTM D41 primed OSB;
➢ Southern Yellow Pine;
➢ ASTM D41 primed Southern Yellow Pine;
➢ ASTM D41 primed structural concrete;
➢ Huber Engineered Woods "ZIP System" Panels (designed and installed to meet wind loads
for project).
Note: Polyglass does not require priming of new or existing plywood sheathing. New or
existing plywood sheathing should be cleaned of all dirt and debris prior to application of
Polystick membranes.
Elastoflex S6G or S6G FR in hot asphalt to:
➢ ASTM D41 primed structural concrete.
Polyflex G or G FR torch -applied to:
➢ ASTM D41 primed structural concrete.
5.5.2 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI 07320
does not address wind uplift resistance of all underlayment systems beneath foam -on tile
systems, where the underlayment forms part of the load -path. The following wind uplift
limitations apply to underlayment systems that are not addressed in FRSA/TRI 07320 and are
used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind
load resistance based on allowable wind loads. Refer to FBC 1609.1.5 for determination of
design wind pressures.
5.5.2.1 Maximum. Design Pressure = -622.5 psf.
Deck: Structural concrete to meet project requirements to satisfaction of AHJ.
Primer: ASTM D41
Underlayment: Polyflex G or G FR torch -applied.
5.5.2.2 Maximum Design Pressure = -315 psf.
Deck: Structural concrete to meet project requirements to satisfaction of AHJ.
Primer: ASTM D41
Underlayment: Polystick TU, Polystick TU P, Polystick TU Plus, Polystick TU Max, Tile Pro,
Polyflex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide
SA-APP Cap Sheet (FR).
5.5.2.3 Maximum Design Pressure = -135 psf.
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Primer: (Optional) ASTM D41
Joints: Min. 4-inch wide strips of Elastoflex SA-V over all plywood joints.
Underlayment: Polystick TU, Polystick TU P, Polystick TU Plus, Polyflex SAP, PolyFlex SAP FR,
Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR)
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1111
Certificate of Authorization #9503 FL5259-1116
Revision 11: 08/17/2012
Page 5 of 10
r I
TRINITYERD
5.5.2.4 Maximum Design Pressure = -90 osf.
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Primer: (Optional) ASTM D41
Underlayment: Polystick TU, Polystick TU P, Polystick TU Plus, Polyflex SAP, PolyFlex SAP FR,
Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR)
5.5.2.5 All other direct -deck, adhered Polyglass underlayment systems beneath foam -on tile systems
carry a Maximum Design Pressure of -45 psf.
5.5.3 Bond=to-Insulation:
➢ Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR)
self -adhered to: ASTM C1289, Type II, Class 1 polyisocya nu rate or Type V
polyisocyanurate-composite insulation; DensDeck DuraGuard; DensDeck Prime; or
SECUROCK Gypsum -Fiber Roof Board.
➢ Elastoflex S6G or S6G FR in hot asphalt to: DensDeck Prime or SECUROCK Gypsum -Fiber
Roof Board.
➢. Polyflex G or G FR torch -applied to: ASTM D41 primed structural concrete; DensDeck
Prime or SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be
attached per minimum requirements of the prepared roof covering manufacturer's Product
Approval. For installations under foam -on tile systems, insulation attachment shall_ be
designed by a qualified design professional and installed based on testing of the
insulation/underlayment system in accordance with FM 4470, Appendix K or TAS 114,
Appendix I
5.5.4 Bond to Mechanically Attached Base Layer:
➢ Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR)
Dual Pro or Tile Pro self -adhered to: ASTM D226, Type I or II felt; Elastobase; Elastobase
P or Mule -Hide Nail Base.
➢ Elastoflex S6G or S6G FR in hot asphalt to: ASTM D226, Type I or II felt; Elastobase;
Elastobase P or Mule -Hide Nail Base.
➢ Polyflex G or G FR torch -applied to: Elastobase; Elastobase P or Mule -Hide Nail Base..
For installations under mechanically attached prepared roof coverings, base layer shall be
attached per minimum codified requirements. For installations under foam -on tile systems,
base layer shall be attached per minimum requirements of FRSA/TRI 07320/8-05 or RAS 120.
5.6 Exposure Limitations:
5.6.1 Elastobase, Elastobase P, shall not be left exposed for longer than 30-days after installation.
5.6.2 Polystick IR-Xe, Polystick TU Max, Dual Pro or Tile Pro shall not be left exposed for longer than
90-days after installation.
5.6.3 Polystick MTS, TU, TU P or TU Plus shall not be left exposed for longer than 180-days after
installation.
5.6.4 Polyflex SAP or SAP FR, or Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not
have an exposure limitation, unless the prepared roof covering is to be adhesive -set tile, in
which case the maximum exposure is 30 days.
5.6.5 Elastoflex S6G or S6G FR or Polyflex G or G FR does not have an exposure limitation, unless
the prepared roof covering is to be adhesive -set tile (Polyflex G or G FR only), in which case
the maximum exposure is 180 days.
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1111
Certificate of Authorization #9503 FL5259-R16
Revision 11: 08/17/2012
Page 6 of 10
r" ti
QTkINI
5.7 For the roof installations governed by the FRSA/TRI 07320/8-05 Installation Manual, Fourth
Edition, use is limited to the following. Reference is made to the FRSA/TRI Technical Brief
titled "Florida High Wind Roof Tile Self -Adhered Underlayment Requirements as of
02/14/2011" for limitations for self -adhering underlayments used beneath tile roof systems.
Table 2: Tile System Options per FRSA/TRI 07320/8-05
System
Underlay
Option
section
Reference
Product(s)
3.02A
1
Batten
Modified Cap Sheet
Elastoflex S6G or Elastoflex S6G FR; Polyflex G or G FR
only
No. 30 / Modified Cap
Base Layer: Elastobase; Elastobase P
System One:
2
3.028
Sheet
Top Layer: Elastoflex S6G or Elastoflex S6G FR; Polyflex G
Mechanically
or G FR
4
3.02D
No. 30
Elastobase; Elastobase P
Fastened Tile,
Unsealed or
Self -Adhered
Polystick MTS; TU; TU P; TU Plus; TU Max; Polyflex SAP or
Sealed
5
3.02E
Underlayment
y
SAP FR; Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet
Underlayment
(FR); Dual Pro; Tile Pro
System
Base Layer: ASTM D226, Type II; Elastobase; Elastobase P;
No. 30 / Self -Adhered
Mule -Hide Nail Base
6
3.02F
Underlayment
Top Layer: Polystick MTS; TU; TU P; TU Plus; TU Max;
Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-
APP Cap Sheet (FR); Dual Pro; Tile Pro
3.02A
1
Batten
Modified Cap Sheet
Elastoflex S6G or Elastoflex S6G FR; Polyflex G or G FR
only
No. 30 / Modified Cap
Base Layer: Elastobase; Elastobase P
System Two:
2
3.02B
Sheet
Top Layer: Elastoflex S6G or Elastoflex S6G FR; Polyflex G
Mechanically
or G FR
Self -Adhered
Polystick TU; TU P; TU Plus; TU Max; Polyflex SAP or SAP
Fastened Tile,
Sealed
4
3.02D
Underlayment
FR; Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet
Underlayment
(FR); Dual Pro; Tile Pro
System
Base Layer: ASTM D226, Type II; Elastobase; Elastobase P;
No. 30 / Self -Adhered
Mule -Hide Nail Base
5
3.02E
Underlayment
Top Layer: Polystick TU; TU P; TU Plus; TU Max; Polyflex
SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap
Sheet (FR) Dual Pro; Tile Pro
1
3.02A
Modified Cap Sheet
Polyflex G or G FR
2
3.02B
No. 30 / Modifed Cap
Base Layer: Elastobase; Elastobase P
System Four
Sheet
Top Layer: Polyflex G or G FR
Self -Adhered
Polystick TU; TU P; TU Plus; TU Max; Polyflex SAP or SAP
Adhesive -Set
4
3.02D
Underlayment
FR; Tile Pro; Mule -Hide SA-APP Cap Sheet or SA-APP Cap
Tile, Unsealed or
Sheet (FR)
Sealed
Base Layer: ASTM D226, Type II; Elastobase; Elastobase P;
Underlayment
Mule -Hide Nail Base
System
5
3.02E
No. 30 / Self -Adhered
Underlayment
Top Layer: Polystick TU; TU P; TU Plus; TU Max; Polyflex
SAP or SAP FR; Tile Pro; Mule -Hide SA-APP Cap Sheet or
SA-APP Cap Sheet (FR)
1
3.02A
No. 30 / Modified Cap
Base Layer: ASTM D226, Type II; Elastobase; Elastobase P
Sheet
Top Layer: Polyflex G or G FR
System Four
Self -Adhered
Polystick TU; TU P; TU Plus; TU Max; Polyflex SAP or SAP
"B":
3
3.02C
Underlayment
FR; Tile Pro; Mule -Hide SA-APP Cap Sheet or SA-APP Cap
Adhesive -Set
Sheet (FR)
Tile, Sealed
Base Layer: ASTM D226, Type II; Elastobase; Elastobase P;
Underlayment
Mule -Hide Nail Base
System
4
3.02D
No. 30 / Self -Adhered
Underlayment
Top Layer: Polystick TU; TU P; TU Plus; TU Max; Polyflex
SAP or SAP FR; Tile Pro; Mule -Hide SA-APP Cap Sheet or
SA-APP Cap Sheet (FR)
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1111
Certificate of Authorization #9503 F11-5259-1116
Revision 11: 08/17/2012
Page 7of10
FTRINITYIERD
6. INSTALLATION:
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published
installation requirements subject to the Limitations set forth in Section 5 herein and the
specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the
substrate thoroughly to remove any dust and debris prior to application, and prime the
substrate (if applicable).
6.3 Elastobase, Elastobase P or Mule -Hide Nail Base:
6.3.1 Shall be installed in compliance with the codified requirements for ASTM D226, Type II
underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed.
6.3.2 For use in non -tile applications:
6.3.2.1 Reference is made to the current edition of the NRCA Steep -slope Roofing Manual and ARMA
recommendations for installing shingle underlayments and flashings
6.3.2.2 Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick,
Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), Dual Pro or
Tile Pro, self -adhered, Elastoflex S6G or S6G FR in hot asphalt or Polyflex G or G FR, torch
applied.
6.3.3 For use in tile applications, reference is made to Polyglass published installation instructions in
conjunction with FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2
herein.
6.4 Polvstick MTS. IR-Xe. TU. TU P. TU Plus. TU Max Polvflex SAP or SAP FR. Mule -Hide
SA-APP Cap Sheet or SA-APP Cap Sheet (FR). Dual Pro or Tile Pro:
6.4.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment
in FBC Sections 1507 for the type of prepared roof covering to be installed.
6.4.2 For non -tile applications:
6.4.2.1 All self -adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR
and Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) should be back -nailed in selvage
edge seam in accordance with Polyglass / Mule -Hide Back Nailing Guide. Nails shall be
corrosion resistant, 11 gauge ring -shank type with a minimum 1-inch diameter metal disk or
Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back -
nailed using the above noted fasteners and spacing, in area marked "nail area, area para
clavar" on the face of membrane. The head lap membrane is to cover the area being back -
nailed
6.4.2.2 All seal -lap seams (selvage laps) must be firmly rolled with a minimum 28 lb. hand roller to
ensure full contact and adhesion. For Dual Pro and Tile Pro, align the edge of the top sheet to
the end of the glue pattern (the sheet will overlap the fabricj.
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-11111
Certificate of Authorization #9503 FL5259-R16
Revision 11: 08/17/2012
Page 8 of 10
\l TRINITYIERD
a � x
fA katil 1 Y�
g_6
9 A
View of Ovelap Seam of Dual Pro and Tile Pro
6.4.2.3 All over -fabric and over -granule end -laps shall have a 6-inch wide, uniform layer of Polyglass
Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing
Cement, Polyglass PG500 MB Flashing Cement, Polystick TU Plus Tile Underlayment Flashing
Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry
Electrometric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade
mastic, applied in between the application of the lap.
6.4.2.4 Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as
crickets, exposed valleys, or exposed roof to wall details
6.4.2.5 Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55
Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement,
Polyglass PG500 MB Flashing Cement, Polystick TU Plus Tile Underlayment Flashing Cement,
Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry
Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade
mastic to the area in need of repair, followed by a minimum 6 x 6 inch patch of the Polystick
material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed,
shall be installed in a water shedding manner.
6.4.2.6 All Polystick membranes shall be .installed to ensure full contact with approved substrates.
Polyglass requires a minimum of 40-lb weighted -roller or, on steep slopes, use of a stiff
broom with approximately 40-lbs of load applied for the field membrane. Hand rollers are
acceptable for rolling of patches, laps (min. 28 lb roller) or small areas of the roof that are not
accessible to a large roller or broom.
6.4.3 For tile applications (not allowed for Polystick IR-Xe):
6.4.3.1 Reference is made to Section 6.4.2 herein in conjunction with FRSA/TRI 07320/8-05
Installation Manual, Fourth Edition, and Table 2 herein, using the instructions noted above as
a guideline.
6.4.3.2 For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the
tile.
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1111
Certificate of Authorization #9503 FL5259-R16
Revision 11: 08/17/2012
Page 9 of 10
F'1�0
TRINITY 11 ERD
6.5 Elastoflex S613 or S6G FR:
6.5.1 Elastoflex S6G or S6G FR shall be installed in compliance with current Polyglass published
installation requirements. For use in nail -on tile applications, reference is made to FRSA/TRI
07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein.
6.5.2 Elastoflex S6G or S6G FR shall be fully asphalt -applied to the substrates noted in Section 5.5.
Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, and off set end -laps
minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete
mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge.
6.6 Polyflex G or G FR:
6.6.1 Polyflex G or G FR shall be installed in compliance with current Polyglass published installation
requirements. For use in tile applications, reference is made FRSA/TRI 07320/8-05
Installation Manual, Fourth Edition, and Table 2 herein.
6.6.2 Polyflex G or G FR shall be fully asphalt -applied to the substrates noted in Section 5.5. Side
laps shall be minimum 3-inch and end -laps minimum 6-inch wide, and off set end -laps
minimum 3 feet from course to course. Side and end laps shall be fully heat -welded and
inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap edge.
6.7 Tile Staging:
6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment. Refer to Polyglass published requirements for tile staging..
6.7.2 Battens and/or Counter -battens, as required by the the manufacturer and FRSA/TRI 07320/8-
05 must be used on all roof slopes greater than 7:12. For roof slopes in excess of 61/4:12,
precautions should be taken, such as the use of battens, to prevent tile sliding during the
loading process.
6.7.3 For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the
tile.
6.7.4 The minimum cure time after installation of self -adhering membranes and before loading of
roofing tiles is forty-eight (48) hours.
7. LABELING:
i
Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the
Accredited Quality Assurance Agency noted herein.
S. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the
installation of this product.
9. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C. Rule 9N-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL, LLC — QUA9625; (314) 578-3406; k.chancellor@us.ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R11
Certificate of Authorization #9503 FL5259-R16
Revision 11: 08/17/2012
Page 10 of 10