HomeMy WebLinkAboutSUBMITTED PAPERSOFFICE U E ONLY:
Date: i Z
Fee Due:
Receipt#
Permit #
PLANNING & DEVELOPMENT SERVICES SC A
�� BUILDING & CODE REGULATION DIVISION �N�D
B
2300 Virginia Avenue
t LUCIQ
Ft. Pierce,
31553 5652
Ounty
46
APPLICATION FOR ALUMINUM STRUCTURES PERMIT
ALL INFO MUST BE COMPLETE & FILLED IN TO BE ACCEPTED
PROJECT INFORMATION
I. LOCATION/SITE ADDRESS: 610 N. Coconut Avenue (Ili! ic)
2. PROJECT NAME: River Park SITE PLAN NAME:
3. PROPERTY TAX ID#: 3419-510-0159-000/0
4. LEGAL DESCRIPTION (attach extra sheets if necessary): River Park Unit 2
i
5. PLAT BK PAGE BLOCK 15 LOT 17
6. PARCEL SIZE: ACRES/SQ FT. LOT DIMENSIONS
7. SETBACKS (ACTUAL) FRONT: BACK: RIGHT SIDE: LEFT SIDE:
8. J 1'PE OF STRUCTURE (CHEC1: ALL APPROPRIATE BOXES FOR EACH AND EVERY TYPE OF STRUCTURE)
**Infill— Under existinq truss roof**
N = New
SG = Slab on Grade
SQUARE FEET OF
TYPE OF CONSTRUCTION
A = Addition
SR = Raised Slab
DIMENSIONS
CONSTRUCTION
R = Rebuild
WD = Wood Deck
Ei SCREEN ROOM
R
❑ NEW EXISTING
12' X 14' 6
' 174
❑ CARPORT/PATIO ROOF
❑ NEW ❑ EXISTING
X
❑ HABITABLE GLASS ROOM
❑ NEW ❑ EXISTING
X
❑ CAT 1, 2 OR 3 SUNROOM
❑ NEW ❑ EXISTING
X
❑ ALUMINUM COMP. SHED
❑ NEW ❑ EXISTING
X
❑ POOL ENCLOSURE
❑ NEW ❑ EXISTING
X
❑ M H ROOF OVER
❑ NEW ❑ EXISTING
X
❑ ROOF SYSTEM OVER
❑ NEW ❑ EXISTING
X
EXISTING ACCESSORY STRUCTURE
❑ OTHER:
❑ NEW ❑ EXISTING
X
❑ ALUM POOL FENCE
Linear feet
TOTAL SQUARE FOOTAGE OF CONSTRUCTION
174
9. VALUE OF CONSTRUCTION: $_ 4 F 0 0 0_ 0 0
The value of construction is used to determine the amount of permit fees to be assessed. St. Lucie County reserves the right to
question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with
similar types of construction activities. If the value is $2500 or more, a RECORDED Notice of Commencement must be submitted
PRIOR TO FIRST INSPECTION.
SLCCDV Form No.: 001-02 Rer.0412612010
OWNER INFORMATION
NAME: Barbara Ilijic
ADDRESS: 610 N. Coconut Avenue
CITY: Port St. Lucie STATE: FL ZIP 34952
PHONE (DAYTIME): (_) EMAIL:
FILL IN NAME AND ADDRESS BELOW IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM
THE OWNER LISTED ABOVE:
FEE SIMPLE TITLEHOLDER: same
ADDRESS:
CITY: STATE: ZIP
PHONE (DAYTIME): L_)
CONTRACTOR INFORMATION
STATE OF FLORIDA REG./CERT #: S CC 13115 0 5 8 6 ST. LUCIE COUNTY CERT #: 25584
BUSINESS NAME: Master Craft Aluminum Products
QUALIFIER'S NAME: Jeff Jackman
ADDRESS: 1634 SE Niemeyer Circle
CITY: Port St. Lucie STATE: FL ZIP 34952
PHONE (DAYTIME): (_) 335-1177 FAX NO.` 335-0860 email: mastercraftaluminum
@gmail.com
ARCHITECT/ENGINEER: n / a
ADDRESS:
CITY: STATE: ZIP
PHONE (DAYTIME): L_)
NOTE: IF APPLICABLE, SUBCONTRACTOR AGREEMENTS MUST BE ATTACHED TO APPLICATION FOR ROOFING, ELECTRIC, PLUMBING,
AND HVAC
ZONING REQUIREMENTS
All such structures will be subject to the requirements of the ST. LUCIE COUNTY LAND DEVELOPMENT CODE.
❑ 2 scaled plot plans showing lot size, dimensions of existing host structure, and proposed aluminum addition. All setbacks
including front, side, rear and distance between adjacent property structures in MH Parks shall be indicated on the plot plan.
❑ 2 sets of color photos for all storm damaged areas to be reconstructed. One picture must include house address number for
inspection verification. ( not required for construction unrelated to storms)
OFFICE USE ONLY
SECTION az-�— TOWNSHIP S� RANGE MAP NO.
�E Additional I
ZONING LAND USE ( t LOT CVG % Permits
/1 u—,i—A
REPORT
BIMS FEE
$
MISC FEES
$
TOTAL FEES
$
CODE
BUILLING & COINING REVIEW
FRONT PLANS VALUE OF CONSTRUCTION
REVIEW q0UJTER ZONING SUPERVISOR EXAMINER VEGETATION USING ]CC TABLE
DATE ?
COMPLETE J
INITIALS
PLAN ;VIEW SPECIFICATION C rCKLIST
PLEASE PROVIDE ONE OF THE FOLLOWING: A / /A
❑ 2 Sets of Detailed Plans: Dated, Signed & Sealed by an Engineer or Architect holding a Florida State professional license.
❑ 2 Sets of Detailed Plans: Designed in accordance with the AAF Guide to Aluminum Construction in High Wind Areas.
❑ 2 Sets of Detailed Plans: Designed in accordance with any Approved Manual per fs-489.113.
(I) ANY PLANS SUBMITTED WITHOUT COMPLYING WITH THE FOLLOWING SHALL BE RETURNED WITHOUT
APPROVAL. ALL PLANS MUST BE IN INK AND ANY NOTATIONS IN PENCIL WILL NOT BE CONSIDERED A PART OF
A SUBMISSION.
• All plans must be legible and must be designed in Architect's Scale on pages which are 81/2" x 11" or larger.
• All relevant tables & details, if using a manual, must be properly highlighted and must match design checklists &
drawings.
• The plan view must include all dimensions; the location of the host structure and all materials must be sized and
identified thereon.
• All elevations must be shown, including 4th wall detail, dimensions and all material must be sized and identified.
• All primary and secondary carrier beams, spans, spacing, gauges must be shown [Example: 2" x 8" x .072"].
• All methods of fastening or other details which are relevant to the design must be identified on the Plans.
• All upright column heights. sizes, spacing and gauges must be shown as follows: [Example: 3" x 3" x .050"].
• All chair -rails, roof purlins, girts, channels, knee -bracing, k-bracing, cable bracing or any other required component
must be sized and identified.
• All ridge beams and super gutter or fascia attachments must be identified.
• All roof pans or composite panels, with gauges and spans, must be sized and identified.
• All footing, slab and ISO pier designs must be on the plans, per the Architect / Engineer's plans & specifications.
• All light metal alloys which are utilized shall be designed in conformity with the Florida Bldg Code of 2010, Chapter 20.
• Barrier railings, if utilized, shall have all materials, fasteners and height specified and shall have self -closing, self -
catching gates with picket spacing.
(II) SITE CONSTRUCTED SHEDS, HAVING ANY ALUMINUM COMPONENT, SHALL MEET ALL OF THE ABOVE
REQUIREMENTS AND THE FOLLOWING ADDITIONAL ITEMS:
(A) 2 copies of the current product approval [i.e. N.O.A. or State of Florida approval] with the proposed "opening" or cladding
component highlighted and with fasteners and design pressures, per FBC 1714, clearly identified.
(B) 2 electric schematics, in accordance with the N.E.C., if applicable.
(C) Design pressures, per ASCE-7, identified on the openings of all Plans.
(III) HABITABLE ROOMS/ADDITIONS DESIGNS SHALL MEET ALL OF THE ABOVE REQUIREMENTS, EXCEPT AAMA
SPECIFICATIONS, AND CHAPTER 13 OF THE FLORIDA BUILDING CODE.
(IV) SUNROOMS (as defined in R202 and FBC 2002.6) MAY BE CONSTRUCTED, SO LONG AS THEY MEET ALL OF THE
ABOVE REQUIREMENTS AND MUST BE IN STRICT COMPLIANCE WITH AAMA/NPEA/NSA2100.02 AND MEET THE
FOLLOWING ADDITIONAL ITEMS:
(1) The designer or engineer will state on all Plans, which Category of Design [3.1.2] will be used, inclusive of the definition.
(2) If designing a Category 4 or Category 5 structure, as defined in the current Edition of 3.1.2.4 and 3.1.2.5, proper energy
calculations and long form equipment sizing calculations shall be required, pursuant to Chapter 13 of the current State of
Florida Building Code.
(V) MOBILE HOMES (FAC 15C-2.0081 - FAC 15C-2.0072): ALL STRUCTURES ADJACENT TO OR NEW ROOF SYSTEMS
(Pan or Composite) OVER EXISTING ADJACENT STRUCTURES TO A MOBILE HOME SHALL REQUIRE:
(a) A 4 th wall or a current, signed original manufacturer's attachment approval letter which includes the model number, serial
number and current owners name and street address.
(b) That the complete guide to H.U.D. specifications be strictly adhered to.
(c) A Certified Florida Engineer may design the manner of attachment of the proposed structure to the host house but shall
assume full responsibility for both structures' integrity by site specific documentation.
CERTIFICATION:
This application is hereby made in order to obtain a permit to do the work and installations as indicated, and to obtain a
certificate of capacity, if applicable, for the permitted work.
NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO
OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT.
NOTICE TO APPLICANT: IN THE EVENT IT IS NOT YOUR RIGHT TITLE OR INTEREST THAT IS SUBJECT TO
ATTACHMENT, THE APPLICANT DOES HEREBY MAKE A GOOD FAITH PROMISE TO
DELIVER A COPY OF THE ATTACHED CONSTRUCTION LIEN LAW NOTICE TO THE
PERSON WHOSE PROPERTY 1S SUBJECT TO ATTACHMENT, AND DOES SO AS A
CONDITION PRECEDENT TO THIS PERMIT
1. if utilizing the AAF Guide to Aluminum Construction in High Wind Zones, I the Contractor/Owner Builder hereby certify
that the components being used, fasteners type and fastening pattern meet all the requirements for the designated wind
zones established by the county and take full responsibility for complying with the submitted design of the structure being
permitted.
2. 1 further certify that all the foregoing information is accurate, that no work or installation has commenced prior to the
issuance of a permit and that all work shall be performed in compliance with all applicable laws regulating construction and
zoning in this jurisdiction. I understand that separate permits may be required for ELECTRICAL, and HVAC, etc., not
otherwise included with this building permit application.
3. 1 , the Contractor / Owner Builder, have verified that the existing foundation meets the requirements of the Engineer of
Record and is in adequate condition to withstand the uplift and weight of the aluminum structure and said structure will not
exceed the footprint of the structure that was in existence prior to removal by the storms.
u
OWNEMIDA
RA OR SIGNATURE
STATE
COUNTY OF St. Lucie
The foregoing instrument was acknowledged before me
me this 2ndday of January , 20 13
by Jeff Jackman
who is personally known X to me, or who has
produced
CON S NAT —
STATE O LORIDA
COUNTY OF_St. Lucie
The foregoing instrument was acknowledged before me
me this 2nd day of January , 2013
by Jeff Jackman
who is personally known X to me, or who has
produced
as identification. SHERYL D. MOORE as identification.
L _ _ NOTARY PUBLIC
"464,0.JY�,� TATE OF FLORIDA SHE YeL,14 MOOT
Signature of Notary r , Comm# EE156461 Signature ofNota NOTARY PUBLIC
t Expires 1115/2016 wwml
STATE OF FLORII
IMPORTANT NOTICES: Comm# EE156461
•Expires 1 /15/201
• TWO (2) SIGNATURES ARE REQUIRED. EACH SIGNATURE MUST BE NOTARIZED. IF APPLYING FOR THIS
BUILDING PERMIT AS AN OWNER/BUILDER, THE OWNER MUST PERSONALLY APPEAR, IN THE OFFICE
LISTED ON THE FRONT OF THE APPLICATION, TO SIGN THIS APPLICATION & THE OWNER/BLDR
AFFIDAVIT.
• ALL SIGNATURES ON APPLICATION SUBMITTED SHALL BE ORIGINAL, SIGNED IN INK. COPIES, FAXES, OR
STAMPED REPRODUCTIONS ARE PROHIBITED.
• WHEN A PERMIT IS AVAILIBLE FOR ISSUANCE BUT IS NOT PICKED UP WITHIN THIRTY (30) DAYS AFTER
NOTIFICATION OF AVAILIBILITY, IT WILL BE VOIDED. IF THE APPLICATION IS RESUBMITTED, AN
ADDITIONAL FEE WILL BE CHARGED.
Property Appraiser - St.Lucie 0—Inty, FL
Page 1 of 1
Barbara Ilijic Record: 1 of 1
Property Identification
Site Address:
610 N Coconut Ave
Sec/Town/Range:
22 :36S :40E
Map ID:
34/22N
Zoning:
RS-4
PROPERTY RECORD CARD
«Prey Next» Spec.Assmnt Taxes Exemptions Permits Home Print
�%,\�CIE 0�G
ParcellD: 3419-510-0159-000-0
Account #: 41900
Use Type: SF Res
City/Cnty: St Lucie County
Ownership and Mailing Legal Description
Owner: Barbara Ilijic RIVER PARK -UNIT 2- BLK 15 LOT 17(MAP 34/22N) (OR 1614-1011)
Address: 610 N Coconut Ave
Port St Lucie FL 34952-1333
Sales Information
Date Price Code
11/19/2002 0 01
12/1/1976 6500 01
Assessment 2012
Deed Book/Page
2012 Final:
64200
OA 1614 / 1011
Assessed:
60564
CV 0261 / 1083
Ag.Credit:
0
Exempt:
35564
Taxable:
25000
Taxes:
587.87
BUILDING INFORMATION
Exterior Features
View:
RoofCover:
SD - Dim Shingle
ExtType: HC - HC
YearBit:
1977
Grade: C - C
EffYrBlt:
1977
StoryHght: 0010 - 1 Story
No.Units:
1
Interior Features
BedRooms: 2
Electric:
MX - MAXIMUM
FullBath: 2
HeatType:
FHA - FrcdHotAir
1/213ath: 0
HeatFuel:
ELEC - Electric
%A/C: 100
%Heated:
100
Special Features and Yard Items
Land Information
Type Y/S Qty.
Units Qual. Cond.
YrBit.
No. Use Type
PA01 - POOL DK-AVG Y
1 411
AV
AV
1999
1 0100-SF Res
SWAV - RES POOL AVG Y
1 405
AV
AV
1999
ENC2 - POOL ENC-AVG Y
1 816
AV
AV
1999
DWC - Driv-Concret Y
1 720
AV
AV
1977
UTL3 - UTILITY AVG Y
1 64
AV
AV
1977
FEN5 - CHAINLINK 5' Y
1 140
AV
AV
1999
Total Land and Building
Land Value: 7900 Acres: 0.2
Building Value: 56300
Finished Area: 1357 SgFt
RoofStruct: HP - Hip
Frame:
PrimeWall: BS - CB Stucco
SecWali:
PrmintWail: DW - Drywall
AvgHt/Fl:
Prm.Flors: CU - Carpet
%Sprinkled: 0
Type Measure Depth
220 -Front Ft 75 115
THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED.
http://www.paslc.org/paslc/prc.asp?prclid=341951001590000
1/3/2013