Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SUBMITTED PAPERS
'OFFICE US .ONLY: Date: Fee- Due: ` Receipt# Permit # PLANNING & DEVELOPMENT SERVICES �( °n BUILDING & CODE REGULATION DIVISION �1" TM 2300 VirginiaAwenue Ft. Pierce, FL 34992-5652 772-462-1553 APPLICATION FOR ALUMINUM STRUCTURES PERMIT ALL INFO MUST BE COMPLETE & FILLED IN TO BE AC6;C TED A PROJECT INFORMATION �t UC 1. LOCATION/SITE ADDRESS: 19 Sierra del Norte (Winfie1Vol l 2. PROJECT NAME: Spanish Lakes SITE PLAN NAME: countryclub Village 3. PROPERTY TAX ID#: 13n6-1 1 1 —0001 —000/0 4. LEGAL DESCRIPTION (attach extra sheets if necessary): East 2 of Section 1 Township 34S Range 39 E less N. 106'9.59' lying N & W of Turnpike Feeder Rd. 5. PLAT BK PAGE BLOCK LOT 6. PARCEL SIZE: ACRES/SQ FT. LOT DIMENSIONS 5 2 ' x 10 9 ' VI1-e P 7. SETBACKS (ACTUAL) FRONT BACK: RIGHT SIDE:%_/ LEFT,.SIDE- ' 8. TYPE OF STRUCTURE (CHECK ALL APPROPRIATE BOXES FOR EACH AND.EVERY TYPE OF STRUCTURE) Under existing truss roof N = New SG = Slab on Grade SQUARE FEET OF TYPE OF CONSTRUCTION A = Addition SR = Raised Slab DIMENSIONS CONSTRUCTION R = Rebuild WD = Wood Deck ❑ SCREEN ROOM ❑ NEW ❑ EXISTING X ❑ CARPORT/PATIO ROOF ❑ NEW ❑ EXISTING X ❑ HABITABLE GLASS ROOM ❑ NEW ❑ EXISTING X J ® CAT .1, 2 OR( UNROOM N ❑ NEW ❑k EXI STING 10 ' X 2 0 ' 200 ❑ ALUMINUM COMP. SHED ❑ NEW .❑ EXISTING X ❑ POOL ENCLOSURE ❑ NEW ❑ EXISTING X ❑ M. H ROOF OVER ❑ NEW ❑ EXISTING X ❑ ROOF SYSTEM OVER ❑ NEW ❑ EXISTING X EXISTING ACCESSORY STRUCTURE ❑ OTHER: ❑ NEW ❑ EXISTING X ❑ ALUM POOL FENCE Linear feet TOTAL SQUARE FOOTAGE OF CONSTRUCTION 9. VALUE OF CONSTRUCTION: $ 8, 0 0 0. 0 0 The value of construction is used to determine the amount of permit fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with sinular types of construction activities. If the value is $2500 or more, a RECORDED Notice of Commencement must be submitted PRIOR TO FIRST INSPECTION. SLCCDV Form No.: 001-02 Ren04126/2010 OWNER INFORMATION t NAME: Mr. & Mrs. George'Winfield ADDRESS: 19 Sierra del Norte CITY: Fort Pierce STATE: FL ZIP 34951 r PHONE(DAYTIME): 466-7691 EMAIL: FILL IN NAME AND ADDRESS BELOW IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE: FEE SIMPLE TITLEHOLDER: ..2 15141 1UG ADDRESS: • w CITY: STATE: L ZIP 3 3 j L PHONE (DAYTIME): CONTRACTOR INFORMATION STATE OF FLORIDA REG./CERT #: SCC 13115 0 5 8 6 ST. LUCIE COUNTY CERT #: 25584 BUSINESS NAME: Mas Craft Aluminum Products QUALIFIER'S NAME: Jef f Jackman ADDRESS: 1634 SE Niemeyer Circle CITY: Port St. Lucie STATE: FL ZIP 34952 PHONE (DAYTIME): 5-1177 FAX NO. 335-0860 email: mastercraftaluminum @gmail.com ARCHITECT/ENGINEER: AAF ADDRESS: CITY: STATE: ZIP PHONE (DAYTIME): L_) NOTE: IF APPLICABLE, SUBCONTRACTOR AGREEMENTS MUST BE ATTACHED TO APPLICATION FOR ROOFING, ELECTRIC, PLUMBING, AND HVAC ZONING REQUIREMENTS All such structures will be subject to the requirements of the ST. LUCIE COUNTY LAND DEVELOPMENT CODE. ❑ 2 scaled plot plans showing lot size, dimensions of existing host structure, and proposed aluminum addition. All setbacks including front, side, rear and distance between adjacent property structures `in MH Parks shall be indicated on the plot plan. ❑ 2 sets of color photos for all storm damaged areas to be reconstructed. One picture must include house address number for inspection verification. ( not required for construction unrelated to storms) OFFICE USE ONLY SECTION TOWNSHIP RANGE MAP NO. .ZONING�� LAND USE LOT CVG % Additional .Permits Required REPORT 9o9 BIMS FEE �,�� MISC FEES $ TOTAL FEES7$ CODE I BUILDING && ZONING REVIEW FRONT PLANS VALUE OF CONSTRUCTION REVIEW COUNTER ZONING SUPERVISOR EXAMINER VEGETATION USING ]CC TABLE DATE COMPLETE IITITIALS �' SPECIFICATION ..EC1KLIST PLEASE PROVIDE ONE OF THE FOLLOWING: ❑ 2 Sets of Detailed Plans: Dated, Signed & Sealed by an Engineer or Architect holding a Florida State professional license. 2 Sets of Detailed Plans: Designed in accordance with the AAF Guide to Aluminum Construction in High Wind Areas. ❑ 2 Sets of Detailed Plans: Designed in accordance with any Approved Manual per fs-489.113. (I) ANY PLANS SUBMITTED WITHOUT COMPLYING WITH THE FOLLOWING SHALL BE RETURNED WITHOUT APPROVAL. ALL PLANS MUST BE IN INK AND ANY NOTATIONS IN PENCIL WILL NOT BE CONSIDERED A PART OF A SUBMISSION. • All plans must•be legible and must be designed in Architect's Scale on pages which are 81/2" x 1 1" or larger. • All relevant tables & details, if using a manual, must be properly highlighted and must match design checklists & drawings. • The plan view must include all dimensions; the location of the host structure and all materials must be sized and identified thereon. • All elevations must be shown, including 4`h wall detail, dimensions and all material must be sized and identified. • All primary and secondary carrier beams, spans, spacing, gauges must be shown [Example: 2" x 8" x .072"). • All methods of fastening or other details which are relevant to the design must be identified on the Plans. • All upright column heights, sizes, spacing and gauges must be shown as follows: [Example: 3" x 3" x .050"]. • All chair -rails, roof purlins, girts, channels, knee -bracing, k-bracing, cable bracing or any other required component must be sized and identified. • All ridge beams and super gutter or fascia attachments must.be identified. • All roof pans or composite panels, with gauges and spans, must be sized and identified. • All footing, slab and ISO pier designs must be on the plans, per the Architect / Engineer's plans & specifications. • All light metal alloys which are utilized shall be designed in conformity with the Florida Bldg Code of 2010, Chapter 20. • Barrier railings, if utilized, shall have all materials, fasteners and height specified and shall have self -closing, self - catching gates with picket spacing. (II) SITE CONSTRUCTED SHEDS, HAVING ANY ALUMINUM COMPONENT, SHALL MEET ALL OF THE ABOVE REQUIREMENTS AND THE FOLLOWING ADDITIONAL ITEMS: (A) 2 copies of the current product approval [i.e. N.O.A. or'State of Florida approval] with the proposed "opening" or cladding component highlighted and with fasteners and design pressures, per FBC 1714, clearly identified. (B) 2 electric schematics, in accordance with the N,E.C., if applicable. (C) Design pressures, per ASCE-7, identified on the openings of all Plans. (III) HABITABLE ROOMS/ADDITIONS DESIGNS SHALL MEET ALL OF THE ABOVE REQUIREMENTS, EXCEPT AAMA SPECIFICATIONS, AND CHAPTER 13 OF THE FLORIDA BUILDING CODE. (IV) SUNROOMS (as defined in R202.and FBC 2002.6) MAY BE CONSTRUCTED, SO LONG AS THEY MEET ALL OF THE ABOVE REQUIREMENTS AND MUST BE IN STRICT COMPLIANCE WITH AAMA/NPEA/NSA2100.02 AND MEET THE FOLLOWING ADDITIONAL ITEMS: (1) The designer or engineer will state on all Plans, which Category of Design .[3.1.2] will be used, inclusive of the definition. (2) If designing a Category 4 or Category 5 structure, as defined in the current Edition of 3.1.2.4 and 3.1.2.5, proper energy calculations and long form equipment sizing calculations shall be required, pursuant to Chapter 13 of the current State of Florida Building Code. (V) MOBILE HOMES (FAC 15C-2.0081 - FAC 15C-2.0072): ALL.STRUCTURES ADJACENT TO OR NEW ROOF SYSTEMS (Pan or Composite) OVER EXISTING ADJACENT STRUCTURES TO A MOBILE HOME SHALL REQUIRE: (a) A 41h wall or a current, signed original manufacturer's attachment approval letter which includes the model number, serial number and current owner's name and street address. (b) That the complete guide to H.U.D. specifications be strictly adhered to. (c) A Certified Florida Engineer may design.the manner of attachment of the proposed structure to the host house but shall assume full responsibility for both structures' integrity by site specific documentation. CERTIFICATION: This application is hereby made in order to obtain a permit to do the work and installations as indicated, and to obtain a certificate of capacity, if applicable, for the permitted work. NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE TO APPLICANT: IN THE EVENT IT IS NOT YOUR RIGHT TITLE OR INTEREST THAT IS SUBJECT TO ATTACHMENT, THE APPLICANT DOES HEREBY MAKE A GOOD FAITH PROMISE TO DELIVER A COPY OF THE ATTACHED CONSTRUCTION LIEN LAW NOTICE TO THE PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT, AND DOES SO AS A CONDITION PRECEDENT TO THIS PERMIT 1. If utilizing the AAF Guide to Aluminum Construction in High Wind Zones, I the Contractor/Owner Builder hereby certify that the components being used, fasteners type and fastening pattern meet all the requirements for the designated wind zones established by the county and take full responsibility for complying with the submitted design of the structure being permitted. 2. I further certify .that all the foregoing information is accurate, that no work or installation has commenced prior to the issuance of a permit and that all work shall be performed in compliance with all applicable laws regulating construction and zoning in this jurisdiction. I understand that separate permits may be required for ELECTRICAL, and HVAC, etc., not otherwise included with this building permit application. 3. I , the Contractor / Owner Builder, have verified that the existing foundation meets the requirements of the Engineer of Record and is in adequate condition to withstand the uplift and weight of the aluminum structure and said structure will not exceed the footprint of the structure that was in existence prior to removal by the storms. OW E 0 C CTOR SIGNATURE S T F FL RIDA COUNTY OF St. Lucie The foregoing instrument was acknowledged before me me this 20 day of December , 2012 by Jeff Jackman who is personally known X to me, or who has produced . \XA CONT NATURE STA FLOR A COUNTYOF St. Lucie The foregoing instrument was acknowledged before me methis 20 day of December 12012 , by Jeff Jackman who is personally known X to me, or who has produced SHERYL D. MOORE as identification. SHERYL D. MOORE as identification. NOTARY PUBLIC NOTARY PUBLIC STATE OF FLORIDA « STATE OF FLORIDA a(r hF# EE166461 COMMAS 64e1 Signature of Notary Expires 1/15/2016 Signature of No eq'1 q§ Expires 1/15/2016 IMPORTANT NOTICES: • TWO (2) SIGNATURES ARE REQUIRED. EACH SIGNATURE MUST BE NOTARIZED. IF APPLYING FOR THIS BUILDING PERMIT AS AN OWNER/BUILDER, THE OWNER MUST PERSONALLY APPEAR, IN THE OFFICE LISTED ON THE FRONT OF THE APPLICATION, TO SIGN THIS APPLICATION & THE OWNER/BLDR AFFIDAVIT. • ALL SIGNATURES ON APPLICATION SUBMITTED SHALL BE ORIGINAL, SIGNED INJNK. COPIES, FAXES, OR STAMPED REPRODUCTIONS ARE PROHIBITED. • WHEN A PERMIT IS AVAILIBLE FOR ISSUANCE BUT IS NOT PICKED UP WITHIN THIRTY (30) DAYS AFTER NOTIFICATION OF AVAILIBILITY, IT WILL BE VOIDED. IF THE APPLICATION IS RESUBMITTED, AN ADDITIONAL FEE WILL BE CHARGED. PLANNING & DEVELOPMENT SERVICES DIVISION BUILDING & CODE REGULATIONS DIVISION 2300 Virginia Ave x- ��� Fort Pierce, FL.34982 BUILDING PERMIT SUB -CONTRACTOR SUMMARY Master Craft Aluminum Products will be using the following sub -contractors for the (Company/Individual Name) project located at Electrical (Street address or Property Tax ID #) It is understood.that if there is any change of status regarding the participation of.any of the sub -contractors listed below, I will. immediately. advise the Building and Zoning Department of St. Lucie County. Trade Name of Company/Contractor St. Lucie County/ State of Florida License. Number Electrical Don Cannon Electric, Inc. 3087 0012,115 Plumbing I3VAC/ Mechanical Roofing Gas OFFICE ,USE, ,ONLY: PERMIT ISSUE DATE: NUMBER: «tz-ao[I D�.wr 4Ak cc -max 56378263 "PIqnt- n Lbadi. ng:" ToJohn I Arrive Jobs 14&ad:;" Start Fmish'Unloada 5 1 1 UN1Plant':"''�?11 Customer Code: Customer Name: -Project Code: Project Name: Ticket Date: Delivery. Address: ry Delivery Instructions: Customer Job Number: Order Code I bate: Project P.O. Number: Order. P.O. Number. Map Page: Map/Row/Column: Dispatcher: Ticket Number. Due On Job: Slump: Truck Number: u Driver NqT�eE; Name: 7, End Use: 0. �,Prl.ver Ir LOAD CUMULATIVE ORDERED MATERIAL CODE PRODUCTION DESCRIPTION UNIT :PRICE QUANTITY QUANTITY U0M .ORICE AMOUNT 0 A F 3UN .1-40 t4"E i"rl 1, OT !"11 j'" C'P!APTIzT_ THA;�'i 6 C Cash Check #/ Auth Code: Signature of Driver Receiving Cash: Cash Received! Total COD Order Amount to Collect Check Without Standby Charges: 71 Charge Comments: WATER ADDED: GAL YARDS IN DRUM: WHEN ADDED. SIGNATURE CURB LINE CROSSED AT OWNER'S/AGENT'S REQUEST: SIGNATURE C3 LOAD WAS TESTED BY: Notice: Our drivers will make every effort to place materials Inere the customer designates, but the SPECIAL TERMS. Any water added is at customers own 'risk. If water Is added on job, concrete strength Company assumes no responsibility for damages inside curb or property line. Customer agrees to the is no longer guaranteed. WARNING: Product may cause skin and/or eye irritation, CAUTION: Matefial terms of sale and delivery and accepts concrete as is. Due to important factors'which are out of our may be hazardous to your safety and health. Please refer to the backside of this ticket for important control after delivery, this Company will not accept any responsibility for the finished results. No*credit for safety handling infognatiqn, a7d to the'material safety data sheets for additional Information. returned concrete. Buyers exceptions and claims shall be deemed waived unless made to us in writing AUTHORIZED SIGNATURE within one business day after the receipt of materials. .68UNIVERSAL INVOICE This Delivery Ticket incorf�-ates herein by reference Buyer's previously executed Credit Application, if any, Seller's Standard Terms and Conditions, Selle Quotatior -iny, and Seller's Order Confirmation (inC "ng .limitations of warranties), as if full set forth on this Delivery Tick {"Agreer '). Seller will provide the Standard Term,, Conditions upon request. Buyer agree that, unless otherwise noted on e front hereof, all quantities and items were delivered as indicated and further expressly agrees t pay in accordance with the A2,re ent. AGGRE4ATE / CEMENT / CONCRETE PRODUCTS / FLY ASH Aggregate products -Are naturally occurring materials including limestone, dolomite, granite, volcanic rock, sand, gravel, and other siliceous materials. Cement products include Portland cement, masonry, pozzolan (Type IP), roof tile, and stucco. Concrete products include Portland cement and aggregate products including limestone, dolomite, granite, volcanic rock, sand, gravel, and other siliceous materials. These products, including fly ash, may contain more than 0.025% crystalline silica. Hazards: Freshly mixed wet cement and/or fly ash can cause eye irritation, skin and eye burns and allergic skin reactions.! Dry concrete and aggregate dust may cause irritation to eyes, skin, and/or respiratory tract. Dust from handling] crushing, grinding, cutting and/or drilling may contain silica, which may cause silicosis and cancer if inhaled.; If ingested, keep warm, at rest, and drink large amounts of water. Fly Ash may contain trace amounts of ammo- .nia. Moisture can cause the ammonia to be released. Inhalation of ammonia can cause coughing and irritation or burns of the nose, throat and lungs. See physician. Health risk depends on duration and level of exposure. i Safety: Avoid contact with eyes and prolonged contact with skin. Wear gloves, eye protection, and appropriate protectiv6 clothing. Wash hands thoroughly with mild soap and water after handling. Avoid breathing dust. If exposed t dust above recommended limits (see MSDS), wear suitable NIOSH-approved respiratory protection. First Aid: In case of eye contact, immediately flush eyes with flowing water for 1.5 minutes. I:f dust is inhaled, move to fres l air. If wet cement contacts skin, rinse thoroughly with water. Get proper medical attention if irritation persists. . CEMEX, Memorial Hermann Tower 929 Lessner, Suite 1900 V7 combined Houston, Texas 77024 02/12 For more information please visit www.cemexusa.com. .Este ticket de entrega'inc.luye como referencia al comprador (ya previamente ejecutada en su aplicaci6n de..cr6dito);, cualquj.er t6rmino estdndar, condiciones del vendedor, propuestas del vendedor y orden de..confirmaci6n del vendedor (coil limitaciones y garantfas), como acuerdo total del ticket de entrega ("Contrato"). El vendedor proveera los t6rminos estandares y condiciones det�l- lados en caso de asf ser requeridos. Con este documento, el comprador acepta los mismos ya antes mencionados y que las cantida es y materiales fueron entregados como se expresa en el mismo. Acepta pagar el monto de acuerdo al contrato; al menos que se ideriti- fique con una nota al frente de este documento. AGREGADOS / CEMENTO / PRODUCTOS DE CONCRETO / CENIZAS VOLANTES Los productos de agregados son materiales naturally como piedra caliza, dolomita, granito, rota volcanica, arena, grava y otr6s materiales silicios. Los productos de cemento incluyen Cemento de tipo Portland, de albanilerfa, pozzolan (tipo IP), azulejo de azotea y estuco. Los productos de concreto incluyen cemento Portland y productos de agregados como piedra caliza, dolomites, granito, coca volcanica, arena,.grava, y otros materiales silicios. Estos productos incluyen cenizas vo.lan.tes (fly ash) la cual puede contener"mds de 0.025% de silicio cristalino. Peligros: Mezela de cemento fresco y/o cenizas volantes pueden causar irritaci6n en los ojos, quemaduras en piel y ojos, ly reacciones al6rgicas en la peel. Conereto seco y polvo de agregados, pueden causar irritaci6n en los ojos, peel y/o en la zona respiratoria. Polvo del. manejo en el trituram:iento, pulido, torte y/o perforaci6n puede contener material s silicos, los cuales pueden causar silicosis pulmonar y cancer si son inhalados. En caso de ser ingeridos, mantenerse en temperatura caliza, reposar y tomar grandes cantidades de agua. Las cenizas volantes pueden contener amoniac6. Se uridad• La humedad puede causar la liberaci6n del amoniaco. La inhalaci6n del amoniaco puede causar toner, irritaci6n o g • quemaduras en la nariz, garganta y pu.lmones..Acudir inmediatamente al medico. El ri.esgo en .la salud depende en la duraci6n y el nivel de la exposici6n. Seguri.dad: Evite el contacto con ojos y contacto prolongado con 1a piel. Use guantes, protecci6n en Jos ojos y Primeros adecuada para protecci6n. Ldvese las manos con jab6n suave y agua despu6s del manejo de materiales. Evite in auxilios; polvos. Si se expone a polvos mds de los limites recomendados, use protecci6n respiratoria. Primeros auxilios: En caso de contacto en Jos ojos, inmediatamente fluya agua en la parte afectada por 15 mini Si se inhala polvo, exp6ngase a aire fresco. Si el cemento fresco tiene contacto con sus ojos, lavelos a fondo agua. Acuda a atenci6n m6dica inmediatamente si la irritaci6n continua. CEMEX, Memorial Hermann Tower 929 Gessner, Suite 1.900 combinado Houston, Texas 77024 Para mds informaci6n visita www cemexusa.com. PLANNING & DEVELOPMENT SERVICES DEPARTMENT BUILDING & CODE REGULATIONS DIVISION BUILDING PERMPr SUB -CONTRACTOR AGREEMENT St. Lucie County Contractor Certification Number: '36,9 State ofFlorida Certification Number (If applicable): ))0,N �1VC , have agreed to be the (Company Name/IndividualNarne) aJ yr—A-"eI CA (— sub -contractor for Electrical (Type of Trade) (Primary Contractor) ro ect located at 19 Sierra del Norte — Spanish Lakes Country Club for the pr oject (Project Street Address or Property Tax ID #) Village It is understood that, if there is any change of status regarding our participation with the above mentioned project, I will immediately advise the Building and Zoning Department of St. Lucie County by personally filing a Change of Contractor notice. (Form: SLCCDV No. 004-00) BUSINESS QUALIFIER (Name of the Individual shown on the Contractor's License) ORIGINAL SIGNATURES ARE REQUIRED SIGNATURE Business Name: Address- City/State/Zip: Phone: !1LXP'FI"T TTQ'P dll%Ti.V- 4v r PRINT NAME 1-4-2013 DATE Vl'1'iVJJ VAJa:+ va�ara PERMIT # ISSUE DATE NOTICE OF COMMENCEMENT Permit No. / `3 1- 000 Tax Folio No. 1306-111-0001-000/0: State of Florida County of St: Lucie The undersigned hereby•gives notice that improvement will. be made to certain. real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement.. Legal Description of Property: (and street address if available): , 19 Sierra del Norte - Spanbsh Lakes Countr)z Club ub v; 1 1 age General description of improvement: Convert rear lanai to Catacfory 3 sunroom: Owner information or Lessee information if the Lessee contracted for the improvement: Name George & Leonara Winfield Address 19 Sierra del Norte, Fort Pierce, FL 34y`)l Interest in property: Name and address of fee simple titleholder (if different from Owner listed above): same Contractor's Name: Master Craft Aluminum Products Contractor Address; 1634 SE Niemeyer Circle, PSL FL Phone Number: 335-1177 34952 Surety (if applicable, a c py of.the payment bond is attached): Amount of bond: $ Name and address: n%a Phone number: Lender Name: n/a Phone Number: Lender's address: Persons thin the State of. Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes: Name: n/a Phone Number: Address: In addition to himself or herself, Owner designates of Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. - Phone number of person or entity designated by owner: to receive a copy of the Expiration date of notice of commencement: (the expiration date may not be before the completion of construction and final payment to the contractor, but will be 1 year from the date of recording unless.a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR -PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITRYOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. M;0F> 0 M_C1 00U-am o0�r"a �Wc j, 0m p �Q ,mcn 0GDi�cS luz w"2� m A fl: Wro 0 4 O V ° m 0 CD z z n 0 C 0 O C Under penalty of perjury, I declare that I have read the foregoing notice of commencement and that the facts stated therein are.true to the best of my knowledge and lief. s.- A (Signature of Owner gr`Lkssee, or Owner's or Homeowner (Signatory's Title/Office) s Authorized Officer/Director/Partner/Manager The foregoing instrument was acknowledged before me this 12 thiay of Dec . 20_12 By George Winfield as homeowner for self Name of Person Type of authoriv!4"LVWWr g) Party on behalf of who instrument was executied L�� &1b NOTARY PUBLIC iloSTATE OF FLORIDA personally known X or produced Identification l✓ (Signature of Notary' ublic - State of Florida)Comm#EE156461 (Print, Type, or Stamp Commissioned Name of Notary Expires 1/15/2016 Type of Identification produced �. : Q,' .. - PAGE 01 01 PY �Sit`Y3 ✓t?�� 0 M!N. SETR>�C!4 RE�kz: _ r 1.7" ►4lba✓9 I PIN CNR zIM 1 SEAR „� 7 V) TECH wry„ v LV x / � 1 - 1�3e-,Je-J. WL�4rz ' MIN. SETBACK REQ, FRONT SfDES 11. 3 5 �- aR.�SIDES_ Jam_ ;�-fiJft� REAR ZQ % G�' r� i P�tDF 7 G toome is < CAIR S10ES - TEC ;_ tog tCPEAR GNU. S Okll .Chapter 4.- Glass-Enclos _ L Ea. , y/ C--' ' 5" COLUMN .(SHOWN)' COLUMN'SIZED PER TABLE 403 THICKNESS AND. LENGTH PLACEMENT OF 1X2 OF ANGLES:BY TABLE .. _ SOLE,PLATE CONCRETE ANCHORS, NUMBER, IN TO DESIGN DIAMETER AND MINIMUM EMBEDMENT PER TABLE 407 (TYPICAL) i :+ 2" MINIMUM, zw . Lu uj EDGE DISTANCE (PER. TABLE 413) .. COLUMN %_FOUNDATION FASTENING (BEARING :WALL) SELECT:LOAD.CONDITIONS BY BEAM SPAN & IN'TABLE 402 ©El al w 3" COL•UMN SHOWN SIZE _ :COLUMN PER TABLE-403 .ANGLE FA - H , PLACEMENT OF 1X2.SOLE SIDE2 EACH #14S�. EAC SIDEy(k1,OC*MIN.) Lu o. PLATE INCIDENTAL.T. 0 DESIGN ANCHOR o u . �-~—yQCONCRETE t.�W EMBEDMENT (MIN )_(TYPICAL) ---- ®:O 2"'MINIMUM o w. ui ` m TyT`�`,i`c .. H .. 0 t_ h < $`�q � � CQLUiJ f p �3 igA v N /_EOU[�[DATION�FASTENING $ (fVONBE-�A;R�hNG"1NALL) C1 r 4 . GONE EAITENEES OM ArrACI;MM o t TIE RESPONSIBUTY OF ME AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND'AREAS (2010 Edition) 2.0 FPage 4 -10 Chapter 4 = Glass :Enclosures ! - 1 X 2 OB .@ PERIMETER NOTE # SE 4jZ0 X 3" 60NG -CREWS-INTO a WOOD HOST AND 15'(0 X 2��/a"LONG CO,nICREfE -SCREWS INT© CONCRETEOR�MASONRY CONSTRUCTION o (1�"EMBEDMENT'PIACiNG24nO.C. AND LL 1NITTHIN 4" "OF'�EACH PERPEN� D CUCAR M-EMBER _ z 1" X 1" X 1/8" ANGLES `2" LONG WITH 2-#8 X 1/2" LONG u S.M.S. AT EACH LEG TYPICAL EACH SIDE, TOP &BOTTOM) o Lu 'H`OST STRUCTURE -ELEMENTS LL . ° o VLu . Lu CONNECTION WITH EXPOSED FASTENERS w x F- 1 X 2 OB @ :PERIMETER REFER TO NOTE .#1 - THIS SHEET Q 2. # 10`S.M.S..'FROM= INSIDE FACE OF z 1 X 2 OBI INTO SCREW SPLINES OF o 1 X 2 OB (1" EMBEDMENT o i 0 II o a 0 io LL 0 Z 0 a U O Ln z Chapter 4 - Glass Enclosures 1 X 2 OB @ PERIMETER FASTEN PER NOTE #1 2" X 2" HOLLOW F— HORIZONTAL (GIRT) I 1" -X 1" X 1/8" ANGLES 2" LONG WITH 2- #8 X 1/2" LONG S.M.S: AT EACH LEG. (TYPICAL TOP & BOTTOM) ti CONNECTION W/ "EXPOSED -FASTENERS 1 X 2 OB @ PERIMETER FASTEN PER NOTE #1 I 2" X 2" HOLLOW F— HORIZONTAL (GIRT) 1 X 2 OB @ PERIMETER ~FASTEN PER NOTE #1 1" X 2-1/4" X 1/8" `RECEIVING CHANNEL �I �•I �I .I i I i POST / COLUMN f� NOTE#: USE 1/4T X 3" LONG LAG SCREWS INTO WOOD HOST AND 1/4"0 X 21/4" LONG CONCRETE SCREWS INTO CONCRETE OR MASONRY CONSTRUCTION (1" EMBEDMENT TYPICAL) SPACING 24" O.C. AND N I i I I WITHIN-4" OF EACH .PERPENDICULAR'MEMBER z I I .2- # 10 S:M.S. FROM INSIDE FACE 0 OF 1.X-2 OB INTO SCREW SPLINES I I OF HOLLOW GIRT (1" EMBEDMENT x\\7 MINIMUM.) Y a CONNECTION W/ CONCEALED FASTENERS D PARTIAL ELEVATIONS / 2 X 2 GIRT TO 1 X 2 CONI AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS (2010 Edition) 2.0 "t-hapter 4 - Glass Enclosures -Exposure,.) BF O w O 0 N , ALLOWABLE SPANS /-HEIGHTS FOR:POSTS IN GLASS ROOMS r(ENClOSED-STRUCTURES) Table 403e 'WIND REGION = 1S0-MPH_ZQW;' Exposure.B Applied'Unit Load=29.0 6005 T5.Allo :Post Spacing (Load Width :Post Extrusions 4'-0" t-4'=6'? 5'-0" 5'-6" 6'-0" 6'-6" T-0" 7-6" 8'-0" 2 X 4 X 0.050 X 0.116 SMB 7-7" T 2`' 610" 6'=6" 6'-3" 5'-11" 5'-9" 5'-7" 5'-5" 2 X 5 X 0:050'X 0.116.SMB 7-11" T-6" 7-1" 6'-9" 6'-6" 6-2" - 5'-11" 5'-9" 5-7" 2 X 6 "X 0.050 X 0.120 SMB 9'-1" 8'-7" 8'-2" 7'4" 7-5" 7-2" 6=10" 6-8" 6-5" 2"X:7 X 0:055 .X 0.120 SMB 10'-4" 9'-9" 9'-3" - 8'40" 8'-5" 8'-1" T-10" T-7" 74, 2 X 8 X 0:072 X 0.224 SMB 16'-1" 15'-6" 14-41" ` 14'-6" 14'-1" 13'-8" IT-4" IT-1" 12'4" 2 X 9 X 0.082 X.0.306 SMB 18'-11" 18'-2" 17-7" 174" 16'-6'' 16'-1" 15'4" 15'-4" 15'-0" 2 X YX 0.090 X 0:090 Hollow 6-7" 6'-4" 6'-1" 5'-11" 5'-9". 5-7" 5'-5" 2 X 3 X 0.125 X .0.12S Hollow . 7-2" 6'-11" 6'-8" 6'-6" 6'-4" 6'-2" T-11" 2 X 4'X 0.050 X 0.050�Hollow 6-6" 6'-1" 5'-9" 5'-6" 5'-T' 5'-1" 4'-11" 4'-9" 4'-7" .2 X 4 X 0.0.90 X 0.090'Hollow 8'-3" T-11" T-8" 7-5" 7-3" T-0" 6'-10" • 6' 7" 2 X 4 X 0.125.X 0:125 Hollow 9'-1" 8'-9" 8'-6" 8'-2" : 7-11" 7-9" 7-7" T-S' T 3" 2 X .5 X 0.050 X 0..050 Hollow 7-7" 7-2". 6'-9" 6-6" 6'-2" .5'41" 5'-9" 5-:6" 3X:3`X 0.090 X 0..090 Square 7'=3" •6-11" 6'4" 6'-6" 6'-4" 6'-2" 5'41" 5'-10" 5'-9" r3 X 3 X 0.125 X 0.125 S uare 7-11" 17M8� T-5" 7-2" 6-11" 6'-9" 6'-7" 6-6" 6'-4" L4 X-4 X-0.125-X-0 125"Hollow-J 10'-9" 10'-4" 9'-11" . 9'-8" 9'-5" 9'-2" 8'-11" 8'-9" 8'=6" ALLOWABLE SPANS,/ HEEGHTS FOR POSTS IN GLASS ROOMS .(ENCLOSED STRUCTURES) Table 403f WIND REGION = 160 MPH ZONE .Exposure B Applied Unit`Load=33.0 " 6005 TS Alloy ' - Post Spacing (Load Width) " . Post Extrusions 4'4' 4'-6" 54' 5-6" 6-0" 6-6" 7-0" T-6" 2 X 4 X 0:050 X 0.116 SMB, 770" .:6'-8'' 6'4' 6'-0" . 5'79" 5'-6" 5-4" 5'-2" 4'-11" 2 X:5 X 0.050'X 0.116 SMB 74" 6-11" 6'-7" 6'-3" 5'-11"" 5'-9" 5'-7. S'-4" 5-2" 2 X 6 X 0.050 X 0.120 SMB 8'-5" 7-11" 7-6" 7'-2'' 6-10" 6'-7" -64- 6-2" 5'-11" " 2 X 7 X'0:055:X:0.120. SMB 9'-7" 1-0" VrT' 8'-2" • 7-10" 7-6" 7-3" 7'70" 6'4" 2.X 8 X 0:072 X 0124 SMB 15-5" 14'-10" 14'-4" 13'-10" IT-6" '13'-1" 12'-9" 12'-6" 12'-3" -2 X 9.X 0.082 X .0.306 SMB 18'-2" 17-5" 16'-10" . 16'-4" 15'-10" 1 15-5" 15-1" 14'-8" 2 X 3 X 0.090 X 0.090 Hollow 6'-3" 6'-0' 'T-10" 5'-8" 5'-6" 5'-4" 5'-2" 2 X 3 X'0.125 X 0.125 Hollow 641' 6'-8" 6'-5" 6'-3' - 64" ` .'5-1011. " S.-9,"K44 5'-6" " 2 X 4 X.0:050 X 0.050 Hollow 5'-11"' . 5'-8" -5'-4" .. 5'-T' 4'-11"- 4'-8" 4'-6" ' 4'-3" . 2 X 4.X.0:090 X 0:090 Hollow . T-11". - . T7' 7-4" 7-1" 6'-11" 6'-9" 6'-7" 6'-3'2X 4 X 0.125 X 0.125'Hollow 8'-9" 8'-5"8' 1"". T-SO" T-8" T-5" T-3":6'-11"2 X 5 X 0.050 X 0.050 Hollow 6'=.11" : 6'-7" :6'-3" 5' 41' . 5'=8" 5'"6". , 5'-3" 3 X 3 X 0.090 X 0.090 Square ,6'-11" " 6'-5" 6'-3" 6'-1" 5'=11" 5'-9" :5'-7"3 X'.3'X 0:125:X 0.125 S uare T-8" E'64' T-1" 6'=10" 6'-8" 6'-6,:6 6'-24 X 4 X.0.125'X `0.125 Hollow 10'-3" " 9'77" j .9'-3" 8'711" 8'=9" 8'76" ". . S'4' ,. 8'-2" C er 4 - Glass Enclosures-`Exposere B o , 0 O F< . ALLOWABLE SPANS •for Secondary WALL MEMBERS ..,... ` Table, 404 H. .. 00 (G RrS'ORCHAIR RAILS - it in Solid Walls) En FOR 140 Wind Zones Exposure B Table 404d .mph (Solid Walls) Uniflnad = 25.3 psf z J W F- O,. z 0 H in H w z Maximum Spacmg (Verbcal).7 ft o c ;.,mawmum.allowable span' 10 LU FOR�150 mph Wind.Zones Exposure B. Table.404d (Solid Walls) '. Unit'Load _ 24.O:psf cu O d a. �. . o' Maximum Spacing'(Uerfical) 7 ft o.c.;-maximum,allowable span 7:10') o s FOR 160 mph Wmd.Zone Exposure B Table 404d (Solid Walls) Unit Load = 33 0. psf z_ 0 U 0 w W: M. OF- o Maximum Spacng (Vertical) 7 ft o c,;_ mawmum allowable span 7' '10 ) z ,. o N - .. .. a" O. Page 4B - 13 AAF :GUIDE TO ALUMINUM CONSTRUCTION .INHIGH WIND AREAS (2010 Edifion)' 2.1 "Load Width /'S acin :Extrusion 9'-D",5'-6�� . ,6�_0�� . 6 T-0" , ' "2X2X.D46 Holiow 4'-4' : 3'-8". 3'-6" 3'=5" 3'-3" ; ,2X3X.050:Hollow 6'-6" 5'=9" 4'-11" 2X4X.05" T-7" 7 _3��.' 6-4 l" ..:.: 6'"-7 ...6�_4�� _ 6 -1" 2X3X.072" , ..710�� T-6" 6 y��.. 6, 3�� -Load Width/-:S acin " 'Extrusion 4:-0':4�_6�� .5'-6" - • 6'-0 , :6 6 7 ;p�� . 2X2X:046'Hollow "_ 3-9,", 3'-6" � 3'-4" 3'-3" 3 1 2'=11" 2X3X.050�Hollow- 4'=6" . 2X4X.05,.. , . 7�_6�� T .::2X3X.072' ..T-4' 6',11 ,,...•: g 7�,., 6�_3�<6'-0 5'-7" ' Load Width /'S acin .' ;Extrusion 4'=0" `'4'-6" 5• p^ _. ; 5'-6" 6'_0" 6 6" T-0". ZX2X.046 Hollow .. :3'-7d. B' S'_ 2' 10" 2X3X:05o'Hollow `5'-7"'...; 5' 3 4'-11"• 4'-9", 4' 7" 4'-2" - 2X4X:05" 7�_0„, 6�_7�� 5����, : ZX3X:072'" 6'-11" '.: ..6' 6 • '. .';6-2" 5'-10�� 1 2 3 4 a) t✓ Lo o rn -� z m a> c cu ., rn� NOT TO SCALE ATE: Jan 02, 2013 AGE DESCRIPTION: Site Plan AGE: OF1 1 Information Owner: Winfield Address: 19 Sierra del Norte Ft Pierce, F134951 Building Information Wind Zone: 160 MPH. Exposure Category: B Minimum Building Dimension: 30 ft. Mean Roof Height: 15 ft. Risk Category: I Design Pressure Calculations [=][:L!o�cation Device IF Device Device Max Positive IF Max Negative ne Width (in) Height (in) Elevation (ft) Pressure (psf) Pressure (psf) 1 Int 101.5 56.375 7 25.1 -27.5 ............................ .... -._............ _ 2 .................................. _.................... _.......................... Int _........... -.._............. _.................................................... 50 ................................................................. ............................... _............. _.............. _......................... _.... 55.875 7 __......... _......................... __........ ----....... ---........................................... 26.4 ...... --...._..._._.... - -28.8 3 End 36 80 7 26.4 -34.5 ............... _.... ........ ..... ........... ..... 4 lk ... ................... _.......... _.._............ _............... End __._....__...... _._._....... ..... _....................................... 108 .--._._................................................................._..... _..._._....... ...... ...... ................................................. 55.875 7 ...... _.... _...................................... ....................... _.............................. 25.0 ......................... ...... _.._... .... __... _.... -31.8 Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. Florida Building Code 2010 ed. Page 1 of 1 tieu�tr�a� x� d.x�a"r a L2 If a' "' a at a...'"•�..',>�_��-`...`c'!:�f.� BCIS Home Log In User Registration , Ho[ Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links. Search Businessl-— Professior 4 US Product User Approval � �' ���USER:-Public User - i > Pro ct or ali: 1"ion Search > ?in;_ ��tior, !!st > Application Detail Y _ Application Type Revision y �, COP Code-Version 20:1D Application Status Approved ` Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email .Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the.Evaluation Report . Florida License Quality Assurance Entity Quality Assurance Contract.Expiration Date Validated By Custom Window Systems Inc. 1900 SW 44th,Avenue Ocala, FL 34474 -(352) 358-6922 Ext 207 mlafevre@cws.cc " Michael LaFevre nilafevre@cws.cc Brian Tenace 1900 SW 44th Ave. Ocala, FL 34474 (352)368-6922 Ext291. btenace@cws.cc Jeff Thompson 1900,SW 44th Ave. Ocala, FL 344.74 (352) •368-692-2 Ext 221 jthompson@cws.cc xterior Doors Swingin ER, rio DoorAssem_41.ie Evaluation. Report from a Florida Registered Architect or a;Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Lucas A. Turner PE-5820.1 Keystone Certifications, Inc. . 03/01/2014 Steven M. Urich, PE . Validation Checklist-•Haidcopy Received Certificate of Independence FL161. R4 COI EvaiReo CVA.S-:E76C (Guardian Door)—,-d` Referenced Standard and Year (of Standard) Standard Year AAMA/101/I:S.2-97 1997 AST.M E 1300-04 2004 Equivalence of'Product Standards http:7/www.floridabuildirig.org/pr/pr_app_dtl.aspx?param=wGEV.X.QwtDgvyf4ngAXh 1045... 1./2/2013 Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 12/01/2011 Date Validated 12/16/2011 Date Pending FBC Approval 12/21/2011 Date Approved 01/31/2012 ......-............. ..._......................... ..... _..... ._................................. ...................... .................. Summary.of Products ............ ................... ....... ...................... ........................................... ................ _.......... ................................. _...................................... -............... _.................. .:-.......................................... FL # Model NumbeLor Name IlDesgoption, 161.11 Guardian Hinged Doore Guardian Hinged Door wGJaze Insert (_Operable or Fluardi ' Limits of Use Installation Instructions Approved for use in HVHZ: No Verified .By: Lucas A. Turner 58201 Approved for use outside HVHZ: Yes Impact. Resistant: No Created by Independent Third Party: Yes Design Pressure: +40/-40 Evaluation Reports Other: Not for use in HVHZ. Primarily used with Screen Rooms. F(:;.6:i. rvr; AE P.Re-.-,, CV,,S-176C I Created by Independent Third Party: Yes 561.2 Guardian Hinged Door Guardian Hinged Door w/ Solid Core. Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes FI- 161 R4, -II 0y,j--7,r.2E> ,':;t: zr : <.n .Qgor m; :I:_:>5. Verified By: Lucas A. Turner 58201 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +40/-40 Evaluation Reports Other: Not for use in HVHZ. Primarily used with Screen Rooms. FL1.6'. g:-i AE Ewtia'er, C`;7S-24 5 s'i=u31—dh a€? ; , . I;,. Created by Independent Third Party: Yes Contact Us :: 1940 North Monroe Street, Tallahassee FL.32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email,addresses are.publicrecor''ds. If you'do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead,,contact the office by,phone or by traditional mail. If you have any questions,., please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address:if they have one. The emails.provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public, To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: t II http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvyf4ngAXh 1045... 1 /2/2013 PRIME DOOR ELEVATION (NON -IMPACT) ALUMINUM NON -IMPACT REQUIREMENT: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE FLORIDA BUILDING CODE, CURRENT 37._,250 EDITION: OVERALL WIDTH 2..GLAZING OPTIONS: (SEE SHEET 3) 3. CONFIGURATIONS: OUYSWING; LEFT OR RIGHT HINGED. FRAME OPENING - ' 4. ANCHORAGE: THE 33 113% STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT. SEE SHEETS 6-7 FOR - DOOR CORE ANCHOR DETAIL. WINDLOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. A 5. DESIGN PRESSURE RATING (SEE BELOW): -NEGATIVE DESIGN LOADS BASED ON TESTED PRESSURE AND GLASS TABLES ASTM E 1300. I -POSITIVE DESIGN LOADS BASED ON TESTED PRESSURE, WATER INFILTRATION TEST PRESSURE AND GLASS TABLES ASTM E 1360. f 6. NOT APPROVED FOR IMPACT RESISTANCE. IMPACT PROTECTIVE SYSTEM IS REQUIRED IN WIND BORNE DEBRIS REGION. 7-5/8 " HINGE 7. ALL FRAMES SCREWED TOGETHER. SMALL JOINT SEAM SEALANT USED AT ALL FRAME JOINTS. — I 8. REFERENCE TEST REPORTS: NCTL=210-3251-1 OVERALL — — 9. 1X OR 2X WOOD,BUCK OR STUD FRAMING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. HEIGHT BUCK AND FRAMING IS RESPONSIBILITY OF ARCHITECT OR ENGINEER OF RECORD. PORCH ENCLOSURE MEMBERS SHALL BE 6063-T5 22_` ALUMINUM MINIMUM WITH MINIMUM WALL THICKNESS OF 0.045 STRUCTURAL INTEGRITY OF PORCH ENCLOSURE TO RECEIVE APPLIED HINGE LOADS FROM WINDOWS SHALL BE VERIFIED BY OTHERS. B FRAME. OPENING HEIGHT 4 7/16" I --- - DOOR I I 1 CORE I I I DESIGN PRESSU E RATING 22.. '1-: P' '� HINGE 7 518" HINGE UPDATED PER 2010 FBC 10/17111 TEF . ' . -A - LUCAS A. TURNER, FL P.E. 58201 B ADDED VENDOR COLUMN TO PARTS LIST 03/131'09 . �'�......... G : • v �' ••. �'- _=�§117ND011 S & DOORS' TABLE OF CONTENTS . '— ' Nc 58201 :t�� ; 1900 SW 44TH AVE.- GENERAL NOTES ....... :.:...................... 1 - µ F ; * = OCALA, FLORIDA 34474 ANCHOR SCHEDULE S NOTES .... '......2 - L.nA.T.—, a zoti-li-ao is:oa-os:oo Y 17 : � _ ^ 'ILL' GLAZING DETAIL......:..........................3 / i> ST`.4TE OF C 4i 4^ GENERAL NOTES SECTIONVIEWS.......................... :....... 4 :O � t`laf: ;A<::a: EXTRUSIONS iia B.Q.M...:................:....$ - PROPRIETARY AND CONFIDENTl4L ]]13O/II, 1000 .- AIDE i1tl' 03l13l2009 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CUSTOM. ��i C;$••••,°Rlt:•'•�j��� <:,r.:: -r-• - INSTALLATION DETAIL....................:.6-7 , 1 .....:r.� .,..••��_ t:;.I ;;. r WRITTEN PERMISSION OF CUSTOM WNDOWS STEREPRODUCTIDN IN MS. INC. SS PROHIBITED.T OR AA WI TOLE THE ��,�I'U"A„;}\1�\� GUARDIAN DOOP. Y A NT C _ •z `.4- CWS-176 1OF7. INSTALL ONE #10 ANCHOR THRU EACH HINGE -INTO SUBSTRATE NOTES: (SEE SHTS 6, 7) - 1. INSTALL ONE ANCHOR AT EACH.LOCATION. SILL ANCHOR SPACING SAME AS HEAD.. 2. SHIM AS REQ'D AT INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX. ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHI GREATER THAN 1116" IS PRESENT. 3. LOAD BEARING SHIMS SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. WOOD SHIMS ARE NOT ALLOWED. 4. 3/16" DIA. ELCO ULTRACON MASONRY ANCHORS MUST BE OF SUFFICIENT LENGTH TO ACHIEVE A MIN. EMBEDMENT OF 1 114" INTO M. THRU FRAME OR THRU 1 BY WOOD BUCK INTO MASONRY. A MINIMUM EDGE DISTANCE OF 2 112", IN ANY DIRECTION, SHALL BE ACHIEV 5. #10 WOOD SCREW ANCHORS THRU FLANGE MUST BE OF SUFFICIENT LENGTH TO ACHIEVE A MIN. EMBEDMENT OF '1 '112" INTO 2 BY V BUCK. A MINIMUM EDGE DISTANCE OF 5116". IN ANY DIRECTION, SHALL BE ACHIEVED. 6. #8 OR STRONGER WOOD SCREW ANCHORS THRU HINGE OR LOCK/DEADBOLT STRIKES MUST BE OF SUFFICIENT LENGTH TO ACHIE� EMBEDMENT OF 1 3/8" INTO 2 BY WOOD BUCK. A MIN. EDGE DISTANCE OF 1/2" SHALL BE ACHIEVED IN EITHER DIRECTION. 7. #10 SMS ANCHORS MUST BE OF SUFFICIENT LENGTH TO ACHIEVE A MIN. PENETRATION OF THREE THREADS BEYOND ANCHOR PLATE SURFACE IN TUBE FRAME INSTALLATION. 8. GLAZED WINDOW FRAME ATTACHED TO DOOR LEAF OPENING IN ACCORDANCE WITH STRUCTURAL PERFORMANCE TEST REPORT NCTL-210-3251.1. ALL GLAZING IS TEMPERED GLASS ONLY. 9. SEAL CORNERS WITH SMALL JOINT SEAM SEALANT. 10. ALL INSTALLATION ANCHORS MUST BE MADE OF OR COATED WITH A CORROSION RESISTANT MATERIAL. DISSIMILAR MATERIALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST BE PROTECTED TO PREVENT REACTIONS. 11. INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS; AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW. 12. INSTALLATION ANCHOR CAPACITIES FOR PRODUCTS HEREIN ARE BASED ON SUBSTRATE MATERIAL WITH THE FOLLOWING PROPERTIES: A. WOOD - MINIMUM SPECIFIC GRAVITY OF G=0.55 (SOUTHERN PINE OR GREATER) B. CONCRETE.- MINIMUM COMPRESSIVE STRENGTH OF 3,200 PSI. C MASONRY STRENGTH_CONFOR NCE TO ASTM C-90. GRADE N, TYPE 1 (OR GREATER). D� ALUMINUPv1- 6063Ti5 (OR GREATER)' 13. SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS IN ACCORDANCE WITH THE CURRENT VERSION OF.THE FOLLOWING REFERENCE DOCUMENTS: FMA/AAMA 100 (FIN WINDOWS). FMA/AAMA 200 (FLANGE WINDOWS), FMANVDMA 250 (BOX WINDOWS), PROPRIETARYAND CONFIDENTAL 11/30/11 FMA/AAMA/WDMA 300(EXTERIOR DOORS). TTiE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CUSTOM WINDOW SYSTEMS; INC. ANY REPRODUCTION IN PART ORAS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CUSTOM WINDOW SYSTEMS. INC. IS PROHIBITED. 1LLA I IUN ANCHUH, I YP. NOTE 2) INSTALL TWO #10 ANCHORS THRU STRIKE PLATE AND DEADBOLT STRIKE . PLATE INTO SUBSTRATE (SEE SHTS 6„ ;LAZED WINDOW FRAME 3EE NOTE 7) ANCHORLAYOUT- (FLANGE) LUCAS A. TURNER, FL P.E. 58201 10117ill T'€.- . �a tsrl..s= MAX FRAME FULL VIEW SINGLE HUNG ALL GLAZING (FIXED & SASH) TEMPERED GLASS.ONLY J . C JYPDATED PER 2010 FBC 10/17/11 TEF LUCAS A. TURNER, FL P.E. 58201 B ADDED VENDOR, COLUMN TO PARTS LIST 03/13/09 tLl15l 11 /YIII!/// fJ j•; • ,�N7ND011`S r.3 562LI-I :';.I DOORS 1900 SW 44TH AVE. C +;• * ; * = .zf— PROPRIETARYAND CONFIDENTIAL i'tt ••'fir P.'?., THE INFORMATION CONTAINED IN 7111S DRAWING IS THE SOLE PROPERTY 11/30/11 ••:: o r� y .•rvt. W114DOWSYS ECU MS INC. ANY REPRODUCTION INPARTGRASAWHOLEWITTHOUTSTHE ,r/issl • •FC��t�� WRITTEN PERMISSION OF CUSTOM WINDOW SYSTEMS. INC. IS PROHIBITED. r///Y��f1�1ilL{Lt�t OCALA, FLORIDA 34474 - DOOR CONFIGURATIONS 1000 ADE 03/13/2009 �`"�` GUARDIAN DOOR ���� NTS �`NO. CN/S-176 3OF7 EXTERIOR INTERIOR SECTION A -A IN' E: SECTION B-B NOTE: ITEMS NOT SHOWN FOR CLARITY1 1,22,24-31,36,37 LtMATED PER 2010 FBC 10117111 1., LUCAS A. TURNER, FL P.E. 58201 E3 JADDED VENDOR COLUMN TO PARTS LIST 03/13/09 ALT. THRESHOLD (1186) ALT, THRESHOLD (1126) %00ittIliff . fl, V ... Vs I% INDOIVS & DOORS NO 5B20l 1900 SW 44TH AVE. 193) z;:---, "v. Si' 1L or .""S SECTION VIEWS 03/13/2009 1000 PROPRIETARYAND CONFIDENTIAL 11130111 ADE THE INFORMATION CONTAINED IN THIS DRAWING IS TIME SOLE PROPERTY OF CUSTOM Ei. WINDOW SYSTEMS, INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE "s, , ;� " - WRITTEN PERMISSION OF CUSTOM WINDOW S)`$TEMS. INC. IS PROHIBITED. C 40F7 ITEM CWS# DESCRIPTION ,VENDOR MATERIAL 1 S-1377 HEAD, Z BAR, OUTSWING KEYMARK ALUM 3 5-1374 JAMB, Z BAR, OUTSWING KEYMARK. ALUM 5 . S-1186 THRESHOLD -_ KEYMARK ALUM 6 S-1193 SADDLETHf2ESHOLD KEYMARK ALUM 7 S-1126 BUMPER THRESHOLD KEYMARK '. ALUM 8 . H-1001 DOOR CORE _ KEYMARK ALUM 9- S-1002 CORNER KEY - KEYMARK ALUM 10 " P-3008 HINGES, - IDEAL SS 11 P-3376, POP RIVET HUB SS 12 P-3280 DEAD BOLT - 3127-A-Q DELANEY SS 13 P-3280. LOCKSET - 3127-A-Q DELANEY SS 14 P-3302 WSTP, .330 x.187, FIN, BLACK SOFT TOUCH ULTRAFAB 15 P-3310 WSTP, .350 x.187,BULB VINYL ULTRAFAB 17 P-3087 GASKET, DOOR KNOB PRATT IND. FOAM 18 P-3204 GASKET,DEADBOLT HOPRODUCTS FOAM 19 P-3584 FOAM CORE ELITE ..24 P-3539 8 x 3/4, QUAD PAN TEK FASTEC STEEL 25 P-3329 , FOAM BLOCK, DOOR KNOB IMPERIAL FOAM 26 P-3350 FOAM BLOCK, FILLER ., , METALS USA 1 DOOR CORE - H-1001 2 3/8" - 1 13116" --I' 4„ OUTSWING HEAD S-1377 2 318" L3J 1 11116" OUTSWING JAMB S-1374 2 5/8" •1116" (33i 1 . 6„ ADJUSTABLE SWEEP S-1300 OUTER FRAME ASSEMBLY DAKIM r_MAR- 13L&_ 1 1/2" MIN, EMBEDMENT [D] y Iy v ` v SEALANT MIN. EMBEDMENT [E] 5116" MIN. EDGE DIST. ;�� 4 v c BETWEEN BUCK AND OPENING r i v v, BY OTHERS 2X 2X WOOD FRAME/2X BUCK- OTHERS ID] INTERIOR o,�� e CONCRETE OR MASONRY =' c ` ° MIN. EDGE DIST. 5/16" ^"' i 1— OPENING BY OTHERS. [A] \ \ [�-1/4" MAX. SHIM IBl ,, .•�•--.,, [D] INSTALLATION ANCHOR, #10 INSTALLATION ANCHOR, -----r #10DIA. WOOD SCREW � ' �_, \ DIA. WOOD SCREW \ ANCHOR, � `� -- ANCHOR. 1/4" MAX. SHIM MIN. EMBEDMENT [ ] [D] \ D / SEALANT BEHIND FLANGE —� � 2X WOOD BUCK/WOOD FRAMING BY OTHERS \ [A] ; 3 5�7 BY INSTALLER.] ............._............._._........._.DOOR ......INSTALLATION HEAD FP,AME..................._...._..__ ANCHOR EXTERIOR INTERIOR INSTALLATION ANCHC 3116" DIA. CONCRETE SCREW ANCHOR. [C] SEAL OR SET SILL IN CONCRETE. OR MASOI PERIMETER SEALANT BY INSTALLER. 1 114" MIN. EMBEDMEI CC] 2 VZ MIN. EDGE DIST (C] C ' VERTICAL SECTION Q6/ .M." \ ' #8 WOOD SCREW THRU HINGE (MIN. EDGE DIST.) [E] EXTERIOR FINISH " ' \\ (1 ANCHOR/HINGE) [E] BY OTHERS. \ EXTERIOR 5116" MIN. EDGE DIST. [D] `PERIMETER SEALANT 1/4" MAX. SHIM[B].................................. __ BY INSTALLER. j -H"l HINGE SIDE DETAIL G �� 2X WOOD SUCK' WOOD FRAMING 1 3E MIN. EMBEDMENT [El INTERIOR 2X WOOD FRAME/2X BUCK / BY OTHERS. (A) i. i -- STRIKE PLATE SCREW #8 WOOD SCREW (2/STRIKE AND DEADBOIT STRIKE. [E] ...._.....--_.._..__.......1.. 0�11 --_.....__ MIN. EMBEDMENT [DI REFERENCE NOTES: EXTERIOR (MIN. EDGE DIST.) [E] [A] SEE NOTE. 9. SHT i j [BJ SEE NOTE 2&3, SHT 2 INSTALLATION ANCHOR, IC] SEE NOTE 4, SHT 2 [DJ SEE NOTE 5; SHT 2 �1 #10 DIA. WOOD SCREW [EI SEE NOTE 6. SHT 2 j PERIMETER SEALANT ANCHOR. BY OTHERS. ID) GLAZED WINDOW FRAME ATTACHMENT EXTERIOR FINISH (SEE NOTE 7, SHEET 2) BY OTHERS. C LiPDATED PER 2010 FBC 10/17/11 TEI _._ LUCAS A. TURNER, FL P.E. 58201 B 1 ADDED VENDOR COLUMN TO PARTS LIST 03113,109 D LOCIQNG SIDE DETAIL 2X WOOD BUCK/WOOD FRAMING ----CONCRETE OR MASONRY BY OTHERS. ZZ PROPRIETARY AND CONFIDENTIAL 11/30/11 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CUSTOM WINDOW SYSTEMS, INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CUSTOM WINDOW SYSTEMS. INC. IS PP.OHISITED. Lls, = l%lND011''S & DOORS 1900 SW 44TH AVE. OCALA, FLORIDA 34474 DOD AIDE 0311312009 NTS `' CWS-176 !C l 5OF7 SCREEN ENCLOSURE MEMBER BY OTHERS [A] INSTALLATION ANCHO #10 SMS. IF] SEALANT BEHIND FLAP BYINSTALLER DOORFRAME HEAD SCREEN ENCLOSURE -- MEMBER BY OTHERS [Al INSTALLATION ANCHOR, #10 DIA. SMS ANCHOR. IF] �= 1/4" MAX. SHIM [B] DOORFRAME JAMB INTERIOR SEALANT BEHIND FLANGE —r/ ! V `INSTALLATION ANCHOR, EXTERIOR BYINSTALLER #8 SMS THRU HINGE / (1 ANCHORIHINGE) IF] EXTERIOR FINISH---/ •�. BY OTHERS. `PERIMETER SEALANT BYINSTALLER. HINGE SIDE DETAIL 4LUttiNUf,1STEEI TUBE 1/4" MAX. SHIM — [e] DOOR FRAME 7 INTERIOR JAMB / --SCREEN ENCLOSURE % MEMBER BY OTHERS [A] EXTERIOR INTERIOR REFERENCE NOTES: — STRIKE PLATE SCREW Noeli #8 X 1 1/2" FH SMS IF] (A) SEE NOTE 9, SHT 1 DOOR FRAME A SILL e [B] SEE NOTE 2R3. SHT 2 [C] SEE NOTE 4. SHT 2 [D] SEE NOTE 5, SHT 2 [E] SEE NOTE 6. SHT 2 `•' / IF] SEE NOTE 7, SHT 2 `--INSTALLATION ANCHOR, #10 SMS ANCHOR LATION ANCHOR, 3, �' EXTERIOR IF] j A. CONCRETE SCREW ANCHOR.7 [C] \ -----'- SEALANT BEHIND FLANGE BYINSTALLER L SEAL OR SET SILL IN / GLAZED WINDOW FRAME ATTACHMENT C UPDATED PER 2010 FBC W117/11 TEF CONCRETE OR MASONRY. (SEE NOTE 7, SHEET 2) LUCAS A. TURNER, FL P.E. 58201 B ADDED VENDOR COLUMN TO PARTS LIST 03/13/U9 PERIMETER SEALANT BY OTHERS. \ l � r G LOCKING SIDE DETAIL `"irCtr, �� ;1' R w rr ] ] '\7� AWAAINUM51'EF..L TUBE 1,`.7 ,T0. lu i,- +lh•: I •i [•(J< 1.1/4" MIN. EMBEDMENT �� v, i i �`� ;;: L .....::._ MUNDOW1 &DOORS [C] r > o > �_ --� CONCRETE OR MASONRY J N� g52L11 1900 SW 44TH AVE. tz + > o + BY OTHERS. w OCALA, FLORIDA 34474 / 33 . S r T6 ctF tt '' INSTALLATION DETAIL - ALUMINUM TUBE MIN. EDGE DIST. '• s r [C] �F�VERTICAL SECTION 11/30/11 PROPRIETARY IHIS D AND GCONFIDENTIALIS1SOLE THE INFORMATION TION CONTAINED IN PHIS DRAWING 19 THE SOLE PROPERTY OF CUSTOM +Ln r� p l{ l r S . .., • 1�' 1000 r ....,.r:?, ADE 03/13/2009 Ig:;, N IN PART CRAS A HOUi7HE WRITTEN PERMWINDOW ISSIONOFCUSMS. INEOMWINDO'NS �� rrr�%f�+,Ai4 ;`,�t� GUARDIAN DOOR NT :;;•Sv, CWS-176 STF_MS..IINC.IS PROHIBITED. •, i..• C 7OF7 ;11onda Building Code Unlim—. Page 1 of 3 771-771 i Y a �. h*3r'a a -ike - w''2 K dxF ^F ilk gPia #gdk g_/ �-�y7.r Fa¢?,.1 ..... µ....� r ...._.......y... L.r .. s.,......_. �,v-.-_..__..a_,.«_......=..t }�` M _, .. ISc's'.'4.iiC.'•'S...:.: 'BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search 3usines �6 r�+�'r'(jjj`Q �`[' gFroduct-Approval 4 rill I.JJ�i.In USER: Public User i - m > Prndhrt �r F. liCa _'?� rch > A;•.?rr'.:ca?irn i.1st > Application Detail --- FL # FL242-R14 r Application Type Revision Code Version 2010 Application Status Approved *Approved by DCA. Approvals by DCA shall be reviewed and ratified by the POC and/or the. Commission if necessary. Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Certification Agency Validated By PGT Industries 1070 Technology Drive Nokomis, FL 34275 (941)48670100 Ext22318 druark@pgtihdustries.com Jens Rosowski jrosowski@pgtindustries.com Jens Rosowski 1070 Technology Drive Nokomis, 'FL 34275 (941) 486-0100 Ext 21140 jrosowski@pgtindustries.com %W,i?,Td' Horizontal Slider Certification Mark or.Listing Miami -Dade BCCO - CER Miami -Dade BCCO - VAL Referenced Standard and Year (of Standard) Standard TAS 201, 202, 203 Equivalence of Product Standards Certified By Product Approval Method Year 1994 Fsal-LE- COP' u http://www.floridabuilding.org/pr/P _app_dti.aspx?param=wGEVXQwtDquUsDrhuM3DG... 1/2/2013 rioncia nunaing uoae unllne _ Page L of 3 Date Submitted 06/06/2012 Date Validated 06/07/2012 Date Pending FBC Approval Date Approved '06/11/2012 Date Revised 12/21/2012 ry of Products FL # _ Model, Number or Name IlDescription 24214=. HR `- Z3tl(+fVon Yrnpaet) Rlu_mmum Horizontal�Roller Window Limits of Use " J D C-erttific on Agency`Certificate Approved for use in HVHZ: Yes zL2=2:._ R9=.. CAC _k:._1:..... ........ '%L_H Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 04/05/2017 Design Pressure: N/A Installation Instructions Other: Please see the Miami -Dade County Notice of FL242.„_R,1..4_._1i_.._1_____,2 1,0Y,._lj`R2___0,.Wdf Acceptance (NOA) for product performance information, Verified By: Miami -Dade BCCO - CER anchorage details, and anchor type, size, and spacing Created by Independent Third Party: information. Evaluation Reports Created by Independent Third Party: 242.211HR - 510 (Large Missile Impact) IlWinGuard Vinyl Horizontal Roller Window Limits of'Use Certification Agency Certificate Approved for use in HVHZ: Yes L242 R14 C C_`(: 1.1-1.1. 4.00,.zef Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant, Yes 02/17/2016 Design Pressure: N/A Installation Instructions Other: Please see the Miami -Dade County Notice of P: 2.4.2.._I`cI:�..._11..._"._,__':. 1.4.:, Acceptance (NOA) for product performance information, .i>.,^d: Verified By: Miami -Dade BCCO - CER anchorage details, and anchor type, size, and spacing Created by Independent Third Party: information. Evaluation Reports Created by Independent Third Party: 242.3 11HR - 610 (Non -Impact) JjWinGuard Aluminum Horizontal Roller Window Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes =i�.2<<: RIA C CAC :i.1. 1:' :.•1,0) Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 07/27/2016 Design Pressure: N/A Installation Instructions Other: Please see the Miami -Dade County Notice of FL242 %141y 11 .11 -11 14,0;W;df Acceptance (NOA) for product performance information, Verified By: Miami -Dade BCCO - CER anchorage details, and anchor type, size, and spacing. Created by Independent Third Party: information. Evaluation Reports Created by Independent Third Party: 242.4 HR - 710 (Impact) jjWlnGuard Aluminum Horizontal Roller Window Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes f1..242 R'14 C 'PIC I.:t Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 12/21/2016 Design Pressure: N/A Installation Instructions Other: Please see the Miami -Dade County Notice of FL242 RIA 17 Acceptance (NOA) for product performance information, Verified By: Miami -Dade BCCO - CER anchorage details, and anchor type, size, and spacing Created by Independent Third Party: information. Evaluation Reports Created by Independent Third Party: 242.5 HR - 810 (Large Missile Impact) Multi -Story Aluminum Horizontal Roller Window Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes. FL2A7 R1.4 C CAC :1.1.-1.:11.4.01., )d Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 01/02/2013 Design Pressure: N/A Installation Instructions Other: Please see the Miami -Dade County Notice of Fl_242 R14 11 1:1.-:1.:1.1.4,0:1.:;df Acceptance (NOA) for product performance information, Verified By: Miami -Dade BCCO - CER anchorage details, and anchor type, size, and spacing Created by Independent Third Party: information. Evaluation. Reports Created by Independent Third Party: 242.6 JJHR - 810 (Non -Impact) Multi -Story Aluminum Horizontal Roller Window Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL242 RIA C�CAC 1,1_1.11_4_G- Approved for use outside HVHZ:'Yes Quality Assurance Contract Expiration Date Impact Resistant: No 01/02/2013 Design Pressure: N/A Installation Instructions Other: Please see the Miami -Dade County Notice of FL247. Jc1.4 II Acceptance (NOA) for product performance information, Verified By: Miami -Dade BCCO -CER http://www.floridabuilding.org/pr/p�_app_dtl.aspx?param=wGEVXFwt]qL E13C.OPODY M®�E MIAMI-DADE COUNTY, FLORIDA PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY 11805 SW 26`h Street, Room 208 AFFAIRS (PERA) Miami, Florida 33175 2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315 2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/pera/ PGT Industries, Inc. 1070 Technology Drive North Venice, FL 34275 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami —Dade County PERA —Product Control Section to be used in Miami —Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami —Dade County .Product Control Section (In Miami —Dade County) and/ or the AHJ (in areas other than Miami —Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami —Dade County Product Controi'Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series f ` waro" Aaumi Horizontal Sliding 'Window — N.L APPROVAL DOCUMENT: Drawing No. MD—HR210-01 titled Series "Horizontal Roller Window Details", sheets 1 through 7 of 7, prepared by manufacturer, dated 10/14/11 with the latest revision, prepared by PGT Industries, Inc., dated 03/23/12, signed and sealed by Anthony Lynn Miller, P. E., bearing the Miami —Dade County Product Control Approval stamp with the Notice of Acceptance number and Approval date by the Miami —Dade County Product Control Section. MISSILE IMPACT RATING: None. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, model/ series and following statement: "Miami —Dade County Product Control Approved" unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami —Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists of this page 1, evidence pages E-1 and E -2, as well as approval document mentioned above. The submitted documentation was reviewed* by Jaime D. Gascon, P. E. /c NOA No. 11-1201.04 Za 12 Expiration Date: April 05, 2017 Yroval Date: April 05, 2012 Page 1 PGT Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Manufacturer's die drawings and sections. 2. Drawing No. MD—HR210-01 titled Series "Horizontal Roller Window Details", sheets 1 through 7 of 7, prepared by manufacturer, dated 10/14/11 with the latest revision, prepared by PGT Industries, Inc., dated 03/23/12, signed and sealed by Anthony Lynn Miller, P. E. B: TESTS 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Forced Entry Test, Type "A" window, Grade 10, per FBC 2411 section 3.2.1, TAS 202-94 and per ASTM F 588-04 5) Deglazing Force Test Method A, per ASTM E 987-88 (2001) 6) Standard Test Method for Determination of Operating Force of Sliding Windows and Doors per ASTM E2068-00 (2008) Along with marked —up drawings and installation diagram of an Aluminum horizontal sliding window, prepared by Fenestration Testing Laboratory, Inc., Test Reports No.'s .FTL-6657 and FTL-6658, dated 10/17/11 and 10/18/11, both signed and sealed by Marlin D. Brinson, P. E. C. CALCULATIONS 1. Anchor calculations and -structural analysis; complying with FBC-2010, dated 11/09/11, prepared by PGT Industries, Inc., dated 03/22/12, signed and sealed by Anthony Lynn Miller, P. E. 2. Complies with ASTM E1300-02/ 04 D. QUALITY ASSURANCE 1. Miami —Dade Department of Permitting, .Environment, and Regulatory Affairs (PERA) E. MATERIAL CERTIFICATIONS 1. None. E-1 Jaime D. Gascon, P.E. Product Control Section Supervisor NOA No. 11-1201.04 Expiration Date: April 05, 2017 Approval Date: April 05, 2012 PGT Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED' F. STATEMENTS 1. Statement letter of conformance and compliance with the FBC-2007 (with the 2009 supplement) and FBC 2010 including the HVHZ, dated 11/07/11,, signed and sealed by Anthony Lynn Miller, P. E. 2. Statement letter of no financial interest and independence, dated 11/07/11, signed and sealed by Anthony Lynn Miller, P. E. 3. Laboratory addendum letter for Test Reports No.'s FTL-6657 and FTL-6658, issued by Fenestration Testing Laboratory, Inc., dated 03/22/12, signed and sealed by Marlin D. Brinson, P. E. 4. Laboratory compliance letter for Test Reports No.'s FTL-6657 and FTL-6658, issued by Fenestration Testing Laboratory Inc., dated 10/17/11 and 10/18/11, both signed and sealed by Marlin D. Brinson, P. E. G. OTHERS 1. None. E-2 Jaime D. Gascv , P. E. Product Control Section Supervisor NOA No. 11-1201.04 Expiration Date: April 05, 2017 Approval Date: Apri105, 2012 GENERAL NOTES: SERIES 210 NON -IMPACT HORIZONTAL ROLLER WINDOW 1) THIS PRODUCT HAS BEEN DESIGNED & TESTED TO COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE, INCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ). 2) SHUTTERS ARE REQUIRED WHEN USED IN WIND-BORNE DEBRIS REGIONS. 3) FOR MASONRY APPLICATIONS IN MIAMI-DADE COUNTY, USE ONLY MIAMI-DADE COUNTY APPROVED MASONRY ANCHORS. HE MATERIALS USED FOR ANCHOR EVALUATIONS WERE SOUTHERN PINE, ASTM C90 CONCRETE MASONRY UNITS AND CONCRETE WITH MIN. KSI PER ANCHOR TYPE, SEE TABLE 1, SHEET 1. 4) ALL WOOD BUCKS LESS THAN 1-112" THICK ARE TO BE CONSIDERED 1X INSTALLATIONS. 1X WOOD BUCKS ARE OPTIONAL IF UNIT IS INSTALLED DIRECTLY TO SUBSTRATE. WOOD BUCKS DEPICTED AS 2X ARE 1-1/2" THICK OR GREATER. 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED TO PROPERLY TRANSFER LOADS TO THE STRUCTURE. WOOD BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD. 5) ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. USE ANCHORS OF SUFFICIENT EMBEDMENT AS SPECIFIED ON TABLE 1, SHEET 1. NARROW JOINT SEALANT IS USED ON ALL FOUR CORNERS OF THE FRAME. INSTALLATION ANCHORS SHOULD BE SEALED. OVERALL SEALING/FLASHING STRATEGY FOR WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS AND IS BEYOND THE SCOPE OF THESE INSTRUCTIONS. 6) SHIMS ARE REQUIRED AT EACH ANCHOR LOCATION WHERE THE PRODUCT IS NOT FLUSH TO THE SUBSTRATE. USE SHIMS CAPABLE OF TRANSFERRING APPLIED LOADS. SHIM TO BE NO MORE THAN 1W THICK. WOOD BUCKS, BY OTHERS, MUST BE SUFFICIENTLY ANCHORED TO RESIST LOADS IMPOSED ON THEM BY THE WINDOW. ) HE 7) DESIGN PRESSURES: A. NEGATIVE DESIGN LOADS BASED ON STRUCTURAL TEST PRESSURE, FRAME ANALYSIS AND GLASS PER ASTM E1300-04. B. POSITIVE DESIGN LOADS BASED ON WATER TEST PRESSURE, STRUCTURAL TEST PRESSURE, FRAME ANALYSIS AND GLASS PER ASTM E1300.04. 8) THE ANCHORAGE METHODS SHOWN HAVE BEEN DESIGNED TO RESIST THE WINDLOADS CORRESPONDING TO THE REQUIRED DESIGN PRESSURE. THE 33 1/3% STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT. THE 1.6 LOAD DURATION FACTOR WAS USED FOR THE EVALUATION OF ANCHORS INTO WOOD. ANCHORS THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE FLORIDA BUILDING CODE FOR CORROSION RESISTANCE. 9) REFERENCES: TEST REPORTS FTL-6657 & 6658: ELCO ULTRACON NOA; ELCO CRETEFLEX NOA; ANSI/AF&PA NOS FOR WOOD CONSTRUCTION AND ADM ALUMINUM DESIGN MANUAL. 10) , THE 210 SERIES HORIZONTAL ROLLER WINDOW WAS FORMERLY KNOWN AS THE 201 SERIES, DESIGN PRESSURE RATING IMPACT RATING VARIES, NOT RATED FOR SEE SHEETS 3 & 4 IMPACT RESISTANCE — 120" WIDTH — 119" BUCK WIDTH SHEETS I—_ B 5 & 6 A GHT SASH VISIBLE FIXED VISIBLE 62" LIGHT "`III/// LIGHT BUCK HEIGHT 26-9/16" SASH VISIBLE 56-3I18" FIXED VISIBLE LGHT LIGHT ALWAYS SEE NOTE A, T B _ REQUIRED THIS SHEET SEE NOTES B & C. - — 3"CORNERS THIS SHE ET;-�""/� f TYP. XOX (1/4-1`/2 1`/4'^'"ELEVATIONS Ir- " 74"WIDTH 73BUCK WIDTH SHEETS TABLE 1: I~ ERR C 2" GHT 71" BUCK HEIGHT 65-719" SASH VISIBLE LIGHT I / 67-1/8" FIXED VISIBLE LIGHT 33-9116" 33-9116" SASH FIXED VISIBLE _ VISIBLE LIGHT LIGHT I SHEETS C 5 & 6 ISHEETS 596 —►T I-- 3.3/16" HI 90" WIDTH - ---- 89" BUCK WIDTH B SHEETS 5&6 — A f FIXED _ VISIBLE / LIGHT / 53, IGHT 82° 56-7/8" SASH VISIBLE LIGHT "`III/// 58-1/8" FIXED VISIBLE / BUCK HEIGHT 26-7116" SASH VISIBLE L// LIGHT ALWAYS SEE NOTE A, B REQUIRED THIS SHEET 3" @ CORNERS SEE NU E5 B & C, THIS SHEET TYP. XOX (1/3-1/3-1/3) ELEVATION Anchor . Group Anchor Substrate Min. Edge Distance Min. Embedment A 1/4" Steel Ullrecon Hollow Block, (ASTM C90) 1" 1-1/4" B #12 Steel SMS (G5) or #12 410 SS SMS P.T. Southern Pine (SG = .55) 9/16" 1.318" , _ A36 Steel, .125" min 318" Min. of 3 threads beyond metal substrate A653 Stud, Gr. 33, 0.0346" min. (20 Ga) 31W Aluminum, 606345, .125" min. 3181• C 1/4" Steel -Ullrecon Concrete (min. 2.7 ksi) 1" 1-318" Grouted -filled Block, (ASTM C90) 2-1/4" 1-314" 1/4" 410 SS CreteFlex Concrete (min. 3.5 ksi) 1" 1-3/4' . Hollow Block, (ASTM C90) 1-314" 1-114" ALWAYS 3" —►I—F;W— `—B T)+— 3-3/16" REQUIRED SEE NOTE D. THIS SHEET @ CORNERS TYP X&EL-EVATIONJOXSIM?) \,1j11111fj/ ELEVATIONS .................................... 1 ANCHOR SPECIFICATIONS............ 1 ANCHOR SPACING/QUANTITIES... 2 DESIGN PRESSURES, XO/OX........ 3 DESIGN PRESSURES, XOX............ 4 INSTALLATION, STD MR ................. 5 INSTALLATION, HDMR................... 6 GLAZING DETAILS .......................... 7 CORNER ASSEMBLY ...................... 7 EXTRUSION PROFILES .................. 8 PARTS LIST ..................................... 8 is (40.58705 Uj- a= Sl A. LYNN MILLER, P.E. P.E.# 58705 WEEPHOLE NOTES. (SEE WEEPHOLE DETAILS, SHEET 7 OF 8): A. REQUIRED IF WINDOW WIDTH IS OVER 67".II B. REQUIRED F WINDOW WIDTH IS OVER 45" AND UP TO 67'. C. REQU RED F WINDOW WIDTH IS OVER 89". D. REQUIRED IF WINDOW WIDTH IS OVER 45". LrLp lial, "4111F 1070 TECHNOLOGY DRIVE N. VENICE, FL 34275 P.O. BOX 1529 NOKOMIS: FL 34274 CERT, OF AUTH. #29296 Revlelon: A SHEETS 5&6 will die GENERAL NOTES & ELEVATION J ROSOWSKI 7711e: oote: HORIZONTAL ROLLER WINDOW DETAILS 12/01/11 Senea/Model: I Scale: I Sheet: Growing No. Rev: HR-210 I NTS 1 1 OF 8 1 MD-HR210-01 1 ANCHOR ON 1 ANCHOR AT EACH SIDE OF CORNER THE MEETING RAIL MIN. 3 ANCHORS IN JAMB FOR WINDOWS UP TO 44", MIN. 4 ANCHORS IN JAMB FOR WINDOWS OVER 44" 1 ANCHOR AT CORNER W MAX. SEE TABLE 2, 1 ANCHOR ON THIS SHEET, FOR 1 ANCHOR ON EACH SIDE OF ANCHOR EACH SIDE OF 1 ANCHOR AT THE MEETING QUANTITIES THE MEETING 1 ANCHOR AT CORNER CORNER MI ANCHORS IN JAMB FOR 17" MAX. O.C. FOR WINDOWS OF WINDOWS UP TO 63" TO 44", N. 4 TALL, 20" MAX. O.C: ANCHORS IN FOR WINDOWS OVER 63" JAMB FOR WINDOWS OVER 44" ®6" MAX. — 8" MAX. 6" MAX. —►I (-+— 6" MAX. FROM. CENTER OF MEETING RAIL (X2) ANCHORAGE FOR ALL XO/OX CONFIGURATIONS 1 ANCHOR AT enwnlcw MIN. 3 ANCHORS IN JAMB FOR WINDOWS UP TO 44"• MIN. 4 ANCHORS IN JAMB FOR WINDOWS OVER 44" 1 1 ANCHOR ON ANCHOR I ANCHOR ON EACH SIDE OF AT EACH SIDE OF THE MEETING FIXED THE MEETING I 8"MAX. —� (�— - — 6"MAX. FROM I� MEETING RAIL (X2) ANCHORAGE FOR ALL XOX (1/3-1/3-1/3) CONFIGURATIONS 6' MAX 170A a a� —L 6" MAX I 1 22-3/4" 1 MEETING RAIL (X2) —�� I�- - TIMAX. O.Ch— ANCHORAGE FOR ALL XOX (1/4-1/2-1/4) CONFIGURATIONS TABLE 2: FRAME TYPE FRAME WIDTH FRAME HEIGHT 383/B" 44" 50-6/8" 63" ANCHOR GROUP ANCHOR GROUP ANCHOR GROUP ANCHOR GROUP A B C A B C A 8 C A B C 53-1/9, 1 1 1 1 1 1 1 1 1 1 1 1 74" 2 2 1 1 2 1 1 1 1 1 1 1 STANDARD 1-MEETING 0' 2 2 2 2 - 2 1 1 2 1 1 1 - RAIL 97" 2 3 2 2 2 2 2 2 1 1 1 1 109" 3 3 2. 2 3 2 2 2 2 1 2 1 129' 1 3 3 3 3 3 2 2 2 2 2 2 1 53.1/8" 1 1 1 1 1 1 1 1 1 1 1 1 1 1 HEAVY_ 74" 2 2 1 2 2 1 2 2 .1 1 1 1 DUTY 85" 2 2 2 2 2 2 2 2 2 2 2 1 MEETING g7" 2 3 2 2 3 2 2 2 2 2 2 2 RAIL 109" 3 3 2 3 3 3 3 3 2 2 2 2 120" 3 4 3 3 4 3.3 3 3 2 2 2 - IA-t I, SKtt I I rUK ANUHUK UKUUV Ut,UK1!' I IUNA-. x0, Ox & xox: EGRESS HEIGHT: WH - 4-5/8) x0 & Ox. EGRESS WIDTH: (WW/2-3-1/2) XOX (114.112-1/4): EGRESS WID7H: (WWl4 - 2-5/16) XOX (1/3.113-1/3): EGRESS WIDTH: _ (W W/3 - 6) X. XO, OX & XOX: SASH VISIBLE LIGHT HEIGHT: (WH-6-1/8) FIXED VISIBLE LIGHT HEIGHT: (WH-4-7/8 XO & OX: SASH & FIXED VISIBLE LIGHT WIDTH: 12 - 3-7/16 XOX (1/4-1/2-1/4): SASH VISIBLE LIGHT WIDTH:. (WW14 - 3-7/16) FIXED VISIBLE LIGHT WIDTH:, (W W/2 - 3-13116) _ XOX (1/3.1/3.1/3): SASH &FIXED VISIBLE LIGHT WIDTH; (WW13 -3-BN 6) Appmved ov -,.plying. ilh it.. FloridaB it hlg CoA Dole o S 2012 O t i �� - • qr Q. ; •. * �� No. 56705 Ra so By: Dore: Ravlalon: NOA# 0 1Conlrol Hy Revieed By: Dote: RWsfan; Desarlpllon: ANCHOR SPACING & QUANTITIES Drown 8y: J ROSOWSKI 1070 TECHNOLOGY DRIVE N. VENICE. FL 34275 P.O. BOX 1529 NOKOMIS; FL 34274 '• ST :••' V'\� .......... ri �S' •"'-'••• ���` 'rrr S/ONA�- �� ` A. (�'(.E.I168705 P.E. P.E.# 68705 Title: HORIZONTAL ROLLER WINDOW DETAILS _ Dote: 12/01/11 Seriea/Modol: Soale: HR-210 NTS Sheaf: 2 OF 8 Drowhq No. MD-HR210-01 Rer. CERT. OF AUTH. #29296 TABLE 3' CXo'oRAT CONFIGURATIONS MAXIMUM DESIGN PRESSURE RATING tps fl FRAME GLASS STANDARD MEETING RAIL HEAVY DUTY MEETING RAIL WIDTH TYPE FRAME HEIGHT FRAME HEIGHT 38-3/8" 44" 50-5/8" E83� 38-3/8" 44" 50-5/8" 63" 72" Glass,1 _., +55.01-90.0 +55.01-90.0 +55.0/-86.9 +55.0/-67.9 +55.01-90.0 +55.01-90.0 +55.0/-86.9 +55.0167.9 N/A 26-1/2" Glass 2 & 3 +55.01-90.0 +55.0/-90.0 +55.01-90.0 +55,0/-90.0 +55.01-90.0 +55.01-90.0 +55.0/-90.0 +55.0/-90.0 +55.01-90.0 Glass 4 & 5 +55.01-90.0 +55.0/-90.0 +55.0/-90.0 +55.0/-90.0 +55.01-90.0 +55.01-90.0 +55.0/-90.0 +55.0/-90.0 +55.01-90.0 Glass 1 +55.01-73.5 +55.0/-61.2 +55.0/-56.0 +49.7/-49.7 +55.0/-73.5 +55.0/-61.2 +55.01-56.0 +49.7/-49.7 , NIA 37" Glass 2 & 3 +55.0/-90.0 +55.0/-90.0 +55.0/-87.2 +55.0/-67.2 +55.0/-90.0 +55.0/-90.0 +55.01-90.0 +55.0/-90.0 +55.0/-77.9 Glass 4 & 5 +55.01-90.0 +55.0/-90.0 +55.01-90.0 +55.01-64.0 +55.0/-90.0 +55.0/-90.0 +55.0/-90.0 +55.0/-90.0 +- , 0l-78.1 Glass 1 +55.0/.-67.5 +53.7/-53.7 +44.6144.6 +35.51-35.5 +55.0/-67.5 +53.7/-53.7 +44.61.44.6 +35.51-35.5 N/A 45" Glass 2 +55.0/-90.0 +55.0/-90.0 +55.01-75.0 +55.0/-57.1 +55.0/-90.0 +55.0/-90.0 +55.0/-89.2 +55.0/-77.2 +55.01-65.8 Glass 3 +55.01-90.0 +65.01-90.0 +55.01-75.0 +65.01-57.1 +55.0/-90.0 +55.0/-90.0 +55.0/-80.3 +55.01-63.9 +55.01-57.1 Glass 4 & 5 +55.01-90.0 +55.0/-90.0 +55.01-90.0 1 +55.0/-71.4 +55.0/-90.0 +55.0/-90.0 +55.0/-90.0 +55.01-77.4 +55.0/-66.0 Glass 1 +55.0/-66.0 +53.1/-53.1 +43.6/-43.8 ,+32.3/-32.3 +55.0/-66.0 +53.1/-53.1 +43.6/-43.6 +32.3/-32.3 NIA 49„ Glass 2 +55.0/-90.0 +55..0/-85.1 +55.0/-70.5 +53.4/-53.4 +55.0/-90.0 +55.01-88.9 +55.0/-79.9 +55.01.68.0 +55.0/-61.3 Glass 3 +55.0/-90.0 +55.0/-85.1 +55.0/-70.5 +53.4/-53.4 +55.0/-90.0 +55.0/-90.0 +55.0l-78.5 +55.01-58.1 +50.61-50.6 Glass 4 & 5 +65.01-90.0 +55.0/-90.0 +55.0/-88.1 +55.0/-66.7 +56.01-90.0 +55.0/-90.0 +55.0/-90.0 +55.01-72.3 +55.0/-61.5 Glass 1 +55.0/-63.7 +52.4/-52.4 +43.5/-43.5 +31.21-31.2 +55.0/-63.7 +52.4/-52.4 +43.5/43.5 +31.21-31.2 N/A 8„ Glass +55.0h90.0 +55.01-81.0 +55.0/-66.7 +50.21-50.2 +55.0/-90.0 +55.0/-85.0 +55.01-73.8 +55.01-59.4 +54.01-54.0 Glass-3` +55.01-90.0 +55.0/-81.0 +55.0/-66.7 ±30T2/ %-% +55.0/-90.0 +55.0/-90.0 +55.01-78.3 +55.01-56.2 +46.8/416.8 Glass 4 & 5 +55.01-90.0 +55.0/-90.0 +55.0/-83.4 +55.01-62.7 +55.0/-90.0 +55.01-90.0 +55.0/-90.0 +55.0/-68.0 +55.01-57.4 Glass 1 +55.0/-59.2 +50.4/-50.4 +42.8142.8 +31.81-31.8 +55.0/-59.2 +50.4/-50.4 +42.8/42.8 +31.8/-31.8 N/A 61" Glass 2 +55.0/-89.2 +55.01-75.1 +55.01-61.1 +45.4/45.4 +55.0/-89.2 +55.0/-79.3 +55.0/-67.2 +51.0/-51.0 +44.0/44.0 Glass 3 +55.0/-90.0 +55.0/-75.1 +55.0/51.1 +45.4/45.4 +55.0/-90.0 +55.0/-90.0 +55.01-77.0 +55.0l-57.2 +46.4/-46.4 Glass 4 & 5 +55.0/-90.0 +55.01-90.0 +55.0/-76.4 +55.0/-56.7 +55.0/-90.0 +55.0/-90.0 +55.0/-82.9 +55.0/-61.5 +51.81-51.8 Glass 1 +55.0l-56.3 +48.5/48.5 +41.6141.6 +32.0/-32.0 +55.0/-56.3 +48.5/48.5 +41.6/41.6 +32.01-32.0 NIA 66' Glass 2 +55.0/=79.7 +55.0/-72.5 +55.0/-58.5 +43.0/-43.0 +55.0/-79.7 +55.0/-77.1 +55.0/-65.2 +49.3/49.3 +41.2141.2 Glass 3 +55.0/-79.7 +55.0/-72.5 +55.0158.5 +43.0/43.0 +55.0/-79.7 +55.0/-79.7 +55.0/-74.9 +55.0/57.6 +47.0147.0 Glass 4 & 5 +55.01-79.7 +55.0/-79.7 +55.01-73.1 +53.8/-53.8 +55.0/-79.7 +55.0/-79.7 +55.0/-79.3 +55.0/58.3 +48.9146.9 Glass 1 +51.1/-51.1 +44,2/44.2 +38.91-38.9 +30.0/-30.0 +51.1/-51.1 +44.2/44.2 +38.9/-38.9 +30.0/50.0 NIA 74" Glass 2 +55.0/-63.5 +55.0/-63.5 +55.01-55.3 +40.01-40.0 +55.0/-63.5 +55.0/-63.5 +55.01.62.0 +47.9147.9 +39.81-39.8 Glass 3 +55.01-63.5 +55.0/-63.5 +55.0155.3 +40.0140.0 +55.0/-63.5 +55.0/-63.5 +55.0/.63.5 +54.11-54.1 +45.0/45.0 Glass 4 & 5 +55.0/-63.5 +55.0/-63.5 1 +55.0/-63.5 +50.0/-50.0 +55.0/-63.5 +55.0/53.5 +55.01-63.5 +54.2/-54.2 +45.1145.1 TARI F 4- Glass Types 1 1/6" Annealed 1/8" Tempered 2 3/16" Annealed 114" Annealed 3 +118'-Annealed-l/4"Alrspece-1/8'_An6eal�� 3116" Annealed-3/16" Airspace-1/8" Annealed 4 3/16" Tempered 1/4" Tempered 5 118" Tempered -IN' Alrspece-1/8" Tempered 3/16" Tempered-3116" Airspace-1/8" Tempered NOTES: 1) USE THIS TABLE FOR ALL XO/OX WINDOWS PER THE ELEVATION ON SHEET 1. DIMENSIONS SHOWN ARE TIP -TO -TIP. 2) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION SHOWN ON THE TABLE. 3) DESIGN PRESSURES MAYBE INTERPOLATED BETWEEN SIZES. CONFIGURATIONS APPLICABLE TO THIS SHEET: ++ xO Cl a eol GX /)lip�u,e,:.., ...�upgane wait the IHmidn B Iildiu Code bat o 2012 NVAN. .`_1.04 o �0 0 o ❑ O � ❑ °0 O O Z LL O o� Lu a� rc W 0 Z w W (if J Q Q. H z c:) z O CN R¢ r O _ rc a � s Hai oZ a 2;'tu o �O O•,, �� m MW o:Z =z:z15 �¢ Ld Ny . TARI F A - =CONFIGURATION MAXIMUM DESIGN PRESSURE RATING (psq FRAME WIDTH TYPE GLASS STANDARD MEETING RAIL HEAVY DUTY MEETING RAIL FRAME HEIGHT FRAME HEIGHT 38-3/8" 44" 50-518" 63" 38-3/8" 44" 50-5/81, 63" 49„ Glass 2 & 3 +55.0/-90.0 +55.01-90.0 +55.0/-76.3 +55.01-59.2 +55.0/-90.0 +55.0/-90.0 +55.01-90.0 +55.0/-78.9 z p Glass 4 & 5 +55.0/-90.0 +55.0/-90.0 +55.0/-89.1 +55.0/-69.1 +55.0/-90.0 +55.0/-90.0 +55.0/-90.0 +55.0F90.0 53-1/8" Glass 2 & 3 +55.0/-90.0 +55,01-84.7 +55.0/-71.4 +55.0/-55.1 +55.0/-90.0 +55.0/-90.0 +55.01-90.0 +55.0/-73.5 Glass 4 & 5 +55.0/-90.0 +55.01-90.0 +55.01-83.2 +55.0/-64.3 +55.01-90.0 +55.0/-90.0 +55.01-90.0 +55.01-90.0 oil. Glass 2 & 3 +55.0/-90.0 +55.0/-76.3 +55.0/-63.9 +49.0/49.0 +55.01-90.0 +66.01-90.0 +55.0/-85.1 +55.0/-65.3 LL z Glass 4 & 5 +55,0/-90.0 +55.0/-89.0 +55.0/-74.5 +55.01-57.1 +55.0/-90.0 +55.0/-90.0 +55.01-90.0 +55.0/-84.5 M 74„ Glass 2 & 3 +55.01-81.0 +55.0/-66.8 +55.0/-55.3 +41.9141.9 +55.01-90.0 +55.0/-88.9 +55.0/-73.7 +55.0/-55.8 Glass.4 & 5 +55.0/-90.0 +55.0/-77.9 +55.0/-64.5 +48.81-48.8 +55.01-90.0 +55.0/-90.0 +55.0/-90.0 +55.0/-72.2 c` 85„ Glass 2 & 3 +55.0/45.6 +55.0/-61.5 +50.4/-50.4 +37.7/57,7 +55.01-90.0 +55.0/-81.8 +55.01-67.2 +50.3/-50.3 Glass 4 & 5 +55.0/-88.2 +55.0/-71.7 +55.0/-58.8 +44.0/44.0 +550-90.0 +55.0/-90.0 +55.0/-86.9 +55.0/-65.0 90" Glass 2 & 3_ +55.01-73.8 +55.0/-59.6 +48.61-48.6 +36.21-36.2 +55.01-90.0 +55.0/-79.5 +55.01-64.8 +48.2/-48.2 Glass 4 & 5 +55.0/-86.1 +55.01-69.6 +55.0/-56.7 +42.2142.2 .+55.0/-90.0 +55.0/-90.0 +55.0/-83.9 +55.01.62.4 Glass 2 +55.0/-90.0 +55.0/-79.5 +55.0/-68.4 +50.81-50.8 +5UII-90.0 +55.0/-85.0 +55.01-73.8 +55.01-59.4 53-1/8" Glass 3 +55.01-90.0 +55.0/-79.5 +55.0/-66.4 +50.81-50.8 +55.0/-90.0 +55.0/-90.0 +55.01-78.3 +55.0/56.2 Glass 4 & 5 +55.0/-90.0 +55.0/-90.0 +55.0/-77.5 +55.0159.2 +55.0/-90.0 +55.0/-90.0 +55.01-90.0 +55.0/-87.5 Glass 2 +55.01-80.4 +55.01-64.9 +52.9/-52.9 +39.31-39.3 +56.01-83.1 +55.0/-72.8 +55.0/-62.0 +47.9/47.9 o d 74" Glass 3 +55:0/-80.4 +55.0/54.9 +52.9/-52.9 +39.3/-39.3 +55.0/-90.0 +55.0/-79.6 +55.0/-70.0 +52.5/-52.5 - Glass 4 & 5 +55.0/-90.0 +55.0/-75.8 +55.0/-61.8 +45.9/-45.9 +55.0/-90.0 +55.0/-90.0 +55.0/-90.0 +55.0/-67.8 Glass 2 +55.0/-74.7 +55.0/-61.2 +49.1/-49.1 +35.8/-35.8 +55.01-74.7 +55.0/-67.2 +55.0/-58.9 +46.8/46.8 z Ivy+ J 85" Glass 3 +55.0/-77.2 +55.0/ 61.2 +49.1/-49.1 +35.8/-35.8 +55.01-81.9 +55.01-71.1 +55.0/-62.8 +47.8/A7.8 Glass 4 & 5 Glass 2 +55.0/-90.0 +55.0/-65.3 +55.01-71.4 +55.0/-58.8 +55.01-57.3 +46.3/-46.3 +41.81.41.8 +33.11-33.1 +55.01-90.0 +55.01-65.3 +55.0/-90.0 +55.0/-60.0 +55.0/-84.6 +53.7/-53.7 +55.0/-61.8 +43.9/ 43.9 97' Glass 3 +55.01-72.5 +55.0/-58.8 +46.3/A6.3 +33.1/-33.1 +55.0/-72.5 +55.0/-63.7 +54.7/-54.7 +44.21-44.2 N Glass 4 & 5 +55.0/-87.0 +55.0/-68.6 +54.1/-54.1 +38.7/-38.7 +55.0/-90.0 +55.0/-90.0 +55.0/-79.9 +55.0/-57.1 Glass 2 +55.01-56.7 +53.4/-53.4 +44.7144.7 +31.21-31.2 +55.0/-56.7 +53.4/-53.4 +48.4/A8.4 +40.5/-40.5 9 G a( s-V +55.0/54.8 +55.0/-55.8 +44.7/-44.7 +:3,1T27-`3,11?22d `)+55.0I-64.8 +55.0/-55.8 +48.2148.2 +39.61-39.6 Glass 4 & 5 +55.0/-84:7 +55.0/-66,5 +52.21-52.2 +36.41-36.4 +55.0/-90.0 +55.01-90.0 +55.0/-77.1 +53,81-53.8 Glass 2 +49.7/49.7 +47.9147.9 +43.6/-43.6 +30.01-30.0 +49.7/49.7 +47.9/-47.9 +44.3144.3 +37.5/-37.5 120" Glass 3 +55.0/-57.6 +51.1/-51.1 +43.6/-43.6 +30.01-30.0 +55.0/-57.6 +51.1/-51.1 +44.1/-44.1 +35.81-35.8 Glass 4 & 5 +55.01-83.2 +55.0/-65.0 +50.9/50.9 +35.01-35.0 +55.0/-90.0 +55.0/-90.0 +55.0/-75.2 +51.7/-51.7 TABLE 6: Glass Types 2 3/16" Annealed 1/4" Annealed 3 178=named V9 Alrspace-1%8"Annealed] 3/16" Annealed-3/16" Airspace-1/6" Annealed 4 3116" Tempered 1/4" Tempered 5 1l8" Tempered-1/4"Alrspace-1/8" Tempered 3116" Tempered-3/16" Airspace-1/8" Tempered NOTES: 1) USE THIS TABLE FOR ALL XOX WINDOWS PER THE ELEVATIONS ON SHEET 1. DIMENSIONS SHOWN ARE TIP -TO -TIP. 2) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXTAVAILABLE WIDTH OR HEIGHT DIMENSION SHOWN ON THE TABLE. 3) DESIGN PRESSURES MAY BE INTERPOLATED mars BETWEEN SIZES. ® CONFIGURATIONS APPLICABLE TO THIS SHEET: 1� - MI <�3 i� . munlvinr. with to Y T- 3n T- 0 z 0 a �0�� c c C, { o •� E C �a 0 o X z_ i-> u LL $ ofLLJ m y� w J U U) � `q L 7f U) J CL z C cZ �(D 0 s� O (ngmN , nn Vi n.x no Z z h _ :z m * �w - :w ¢ 0: 2 '•. Cq z Fz ` INSTALLATION OPTION 1 CONCRETE/CMU STANDARD MEETING RAIL O 1XWOOD INSTALLATION ANCHORS INTO 2X WOOD. PER ANCHOR TYP. ANCHOR TYPE, REQUIREMENT BUCKSTRIP, CONCRE OPTIONAL TE EMBEDMENT AND EDGE SEE NOTE 2, O EDGE < 80 ADDON 2X WOOD DISTANCE i- EMBEDMENT DISTANCE PER SUBSTRATE, THIS SHEET. + " ; . P R MU SEE TABLE 1, SHEET 1. FLANGE Qa 114" MAX 11 ANCHOR HEAD, SHIM REQUIRE- SILLBJAMBS EDGE 23 93 30 90 10.ti•�:.. MENT EMBED- DISTANCE a X 54 X MENT 44 SASH` —� SASH TYP. ANCHOR �I VISIBLE O - VISIBLE Its 1 TYPE, EMBEDMENT 57 LIGHT LIGHT EDGE AND EDGE WIDTH WIDTH DISTANCE I DISTANCE PER F I II SUBSTRATE,SEE 78, - IXED 74 itTABLE 1, SHEET 1. 25 24 VISIBLE 70 II I 60 � II W DTH 5 EMBED- \ I 21 STANDARD STANDARD _ II II 5 EXTERIOR B 1X WOOD j INSTALLATION MEETING RAIL MEETING RAIL BUCK MENT FIXED ii j� II OPTION 2 INSTALLATION . {I I II III INSTALLATION VISIBLE O'YION _3 LIGHT ANCHORSDRBUCKWIDTH HEIGHT INTOMASONY. TIP -TO -TIP WIDTH INSTALLATIONtNC HORS TFRICKSTRIP TIP -TO -TIP - �j I� I vSASH HORIZONTAL SECTION A -A ± : , INTO' AS , Y. HEIGHT I III LIGHT 1/4" MAX. SHIM II ij it HEIGHT TYP. ANCHOR TYPE,'` 1 I II I 1/72 STEEL 5 4 2X WOOD a HET G HT I II II X SELF -DRILLING 10 X 71 EMBEDMENT AND EDGE II �I EMS (G5), SEE TABLE SEE TABLE DISTANCE 1, SHEET 1. f I 1, SHEET I. 24 DADEAPPROVED =___ = _�_= — T II II 32 MULLION, ALUMINUM, O 31 STEEL FRAMING OR STEEL SASH VISIBLE STUD. SEE SUBSTRATE LIGHT WIDTH 57 I PROPERTIES, TABLE 1. 4"CUTLENGTH SHEETI. 12 ® EACH 3 MEETING RAIL EXTERIOR 25 FIXED VISIBLE _ INSTALLATION � LIGHT WIDTH TYP. ANCHOR TYPE, OPTION4 V STANDARD 6 INSTALLATION EMBEDMENT AND EDGE MEETING RAIL OPTION 1 INSTALLATION 2 DISTANCEPER BUCK WIDTH INSTALLATION ANCHORS SUBSTRATE, SEE TIP -TO -TIP WIDTH ANCHORS INTO 2X 29 TABLE 1, SHEET 1. DIRECTLY INTO METAL. HORIZONTAL SECTION C-C WOOD. 1X WOOD i BUCKSTRIP, NOTES: SEE NOTE 2, 1) USE ONLY SUBSTRATE -APPROPRIATE ANCHORS LISTED ON TABLE 1 OF SHEET 1. FOLLOW EMBEDMENT AND EDGE THIS SHEET. DISTANCE LIMITS. ANY INSTALLATION OPTION SHOWN MAY BE USED ON ANY SIDE OF THE WINDOW. Approved ns mnlplying tvidl II 1/4" MAX SHIM 2) ALL WOOD BUCKS LESS THAN 1-1l2" \ \ 1 1 1 1 1 1 111 Doto�lo ° Id„" CO1 , r THICK ARE TO BE CONSIDERED 1X \��� oN`i _YNN - 4,, '� Revised By. Dole: Revlslon: NOA+1.. - p' ;•,e , INSTALLATIONS. 1X WOOD BUCKS ARE `� ,�� �(�' r • nu a ;,,pi nlru 1X WOOD ' CONCRETE.PER OPTIONAL. UNIT MAY BE INSTALLED C1 �,\CENSF •., ` BUCK " • ANCHOR DIRECTLY TO SUBSTRATE. WOOD BUCKS P' •'. * Revlaed By: Dole: Revlafon: Dy EXTERIOR REQUIREMENT DEPICTED AS2XARE 1-1/2"THICK OR *: No.W05 GREATER. 1X AND 2X BUCKS (WHEN _ * ` USED) SHALL BE DESIGNED TO PROPERLY ® Deaoripllon: Drawn By: INSTALLATION TRANSFER LOADS TO THE STRUCTURE. �� ' 3 Eq�;' 4= INSTALLATION DETAILS, STD MR J ROSOWSKI OPTION 3 WOOD BUCK DESIGN AND INSTALLATION ST �/� VERTICAL SECTION B-B INSTALLATION ANCHORS IS THE RESPONSIBILITY OF THE 1070 TECHNOLOGY DRIVE Rlle: Dote: ENGINEER OR ARCHITECT OF RECORD. i F N. VENICE, FL 34275 HORIZONTAL ROLLER WINDOW DETAILS 12/01/11 THROUGH iX BUCKSTRIP MAXIMUM SHIM THICKNESS TO BE RECORD. i'i1SS/ONAli- �?�` P.O. BOX 1529 INTO MASONRY. //vllf llllt\\ N01(OMIS, FL 34274 Series/Model: Soule: Sheet: Orowing No. Rev: A. LYNN MILLER, P.E. CERT. OF AUTH. #29296 HR-21O NTS 5 OF 8 MD-HR21 O-01 P.E.d 58705 INSTALLATION OPTION 1 INSTALLATION ANCHORS INTO 2X WOOD. OPTIONAL 2X WOOD 80 ADDON {� EDGE I DISTANCE FLANGE @ HEAD, SILL & JAMBS EDGE DISTANCE EMBED. MENT I 1 TYP. ANCHORDM TYPE, EMBEENT AND EDGE — I� I DISTANCE PER I� I� SUBSTRATE,SEE TABLE 1, SHEET 1. I FIXED VISIBLE LIGHT HEIGHT TIP -TO -TIP HEIGHT BUCK 0 HEIGHT 1X WOOD 1�: •.. BUCK CONCRETE PER EXTERIOR ANCHOR -REQUIREMENT - CUNCRETEICMU PER ANCHOR REQUIREMENT ►-� EMBEDMENT 1!4" MAX I SHIM •° INSTALLATION OPTION 2 INSTALLATION ANCHORS DIRECTLY INTO MASONRY. SASH VISIBLE LIGHT HEIGHT HEAVY DUTY MEETING RAIL( X SASH I' O VISIBLE Its i ir_ur �- ) FIXED 24 VISIBLE LIGHT WIDTH EXTERIOR I'j 7 HEAVYDUTY V MEETING RAIL BUCK WIDTH TIP -TO -TIP WIDTH HORIZONTAL SECTION A -A 1/4" MAX. SHIM I� H12 STEEL II X SELF -DRILLING 10 11 SMS (GS). SEE TABLE X' 1, SHEET I. ___ ___ — ____-- DADE APPROVED V�4'CUTLENGTH MULLION, ALUMINUM, STEEL FRAMING OR STEEL SASH VISIBLE _ STUD. SEE SUBSTRATE LIGHT WIDTH PROPERTIES, TABLE I,ACHSHEET 1. TING RAIL EXTERIOR 25 INSTALLATION TYP. ANCHOR TYPE, OPTION 4 v HEAVY DUTY EMBEDMENT AND EDGE DISTANCE PER INSTALLATION MEETING RAIL 7 SUBSTRATE, SEE ANCHORS DIRECTLY INTO TABLE 1, SHEET 1. METAL. BUCK WIDTH 1X WOOD NOTES: TIP -TO -TIP WIDTH BUCKSTRIP; 1) USE ONLY SUBSTRATE -APPROPRIATE SEE NOTE 2 THIS SHEET. ANCHORS LISTED ON TABLE 1 OF SHEET 1. HORIZONTAL SECTION C-C FOLLOW EMBEDMENT AND EDGE DISTANCE 1/4" MAX SHIM LIMITS, ANY INSTALLATION OPTION SHOWN MAY BE USED ON ANY SIDE OF THE WINDOW. VICENS6 '•. .p . • 2) ALL WOOD BUCKS LESS THAN 1-1/2"THICK � Q• ; ' ARE TO BE CONSIDERED 1X INSTALLATIONS. 1X • :` WOOD BUCKS ARE OPTIONAL. UNIT MAY BE No. 58705 _ INSTALLED DIRECTLY TO SUBSTRATE. WOOD -_ * -_ ° BUCKS DEPICTED AS 2X ARE 1-1/2" THICK OR �,yQ�••�— INSTALLATION GREATER. IX AND 2X BUCKS (WHEN USED) •, T TE F OPTION 3 SHALL BE DESIGNED TO PROPERLY TRANSFER •, ST TE F : �<[/ RTICAL SECTION B-B INSTALLATION ANCHORS LOADS TO THE STRUCTURE. WOOD BUCK DESIGN AND INSTALLATION IS THE , '\ •'•.,FLORIDP;.•' \ ��i� ""' 1070 TECHNOLOGY DRIVE THROUGH 1X F THE ENGINEER OR''s// S ��G N. VENICE, FL 34275 NTO MASONRY. ARCHITECT ARCHIOTECTILITY OF RHCORD. MAXIMUM SHIM ONAI- `��,�` P.O. BOX 1529 THICKNESS TO BE 114". A. LYNN MILLER, P.E. NOKOM_ IS,' FL 34274 P.E.458705 F CERT. OF AUTH. 129298 1x WOOD TYP. ANCHOR TYPE, BUCKSTRIP, ' EMBEDMENT AND EDGE SEE NOTE 2, ?CONCRETE DISTANCE PER SUBSTRATE. THIS SHEET._ OR CMU SEE TABLE 1, SHEET 1. PER ANCHOR REQUIRE- i0 MENT X SASH aa.l4l-l.tiy. VISIBLE I LIGHT EDGE WIDTH DISTANCE 74 70 5 \ / 1X WOOD EMBED- MENT HEAVY DUTY DINSTALLATION MEETING RAIL BUCK OPTION 3 _ ��NNSTAtttATION ANCHORS T}�RO�'H 1 P UCKSTRIP I M, ONRY. WEFRRIEE 4 WOOD TYP. ANCHOR TYP' �2X EMBEDMENT AND O E DISTANCE PER SU • RATE, SEE TABLE 1, SHE O FIXED VISIBLE LIGHT WIDTH r— INSTALLATION OPTION 1 INSTALLATION ANCHORS INTO 2X� WOOD. Approve vlthfhol FloridnF3Si1 it aV ►�nfepY -r or4_ Revfeion: NOAiI � - Pro ont 1,o+ Revision: Dye"' ` INSTALLATION DETAILS, HD MR J ROSOWSKI Title: Dote: HORIZONTAL ROLLER WINDOW DETAILS 12/01/11 Serfes/Model: Scale: Sheaf: orowfn9 No. Rev: HR-210 NTS 6 OF 8 MD-HR210-01 .330" .250" 0.1 r, 1.600" OSILL ASSEMBLY DETAILS OSILL ADAPTER WEEPHOLES WEEPHOLE DETAILS SHOWN WITHOUT WEEPHOLE COVERS. SEE SHEET 1 FOR OUANTITYAND SPACING RAIL 1/8" ANNEALED OR _ TEMPERED GLASS 90 54 I I .382"MIN. jl GLASS BITE j 81 1/8" GLAZING DETAIL 1/16"ANNEALED OR _ I 1/4"ANNEALED OR TEMPERED GLASS TEMPERED GLASS 55 Ij 91 56 II 92 1 .362"MIN. jjj .382"MIN. . GLASS BITE 1 jj GLASS BITE j �1 s1 81 3/16" GLAZING DETAIL 1/4" GLAZING DETAIL 112" MIN. GLASS STACK 118"ANNEALED OR 1/4"AIRSPACE TEMPERED GLASS 118" ANNEALED OR I TEMPERED GLASS I 57 h 93 I li .302"MIN. - jl GLASS BITE Ij 81 53 1/2" I.G. GLAZING DETAIL 114" AIRSPACE 1/2" MIN. GLASS STACK 3/16"ANNEALED OR -- 3/16"AIRSPACE TEMPERED GLASS 1/8"ANNEALED OR TEMPERED GLASS 57 I!I `I 94 .382' MIN. GLASS BITE 81 52 1/2" I.G. GLAZING DETAIL 3116" AIRSPACE es complying With the N44ing Coddo :Lo6(�12 Y 2 .- 0 0 O cl No o (� 0 CO JQ Z_ LL O LLI 0 Z LU o a Z o Lu 0 Of \1111)iiillf// ,w u 6.•. ,mod _ Z;co 6 0 O,.Z-n 0-�33 >•, cl) `Za J 7ti 4V�� b ..0 x\ 11111111p"`v\ TARI E 7- Item Dwg# Part# Description Material 1 215B 6215W Frame Head 6063-T6 2 264 6264W I Frame Sill 6063-TB 3 265 62658W Sill Adapter 6063-T6 4 218A 6218W Frame Jamb (Fixed) 6063-T6 5 219 61088W Frame Jamb (Operable) 6063-T5 6 220B 6220W Fixed Meeting Rail 6063-T6 7 267 6267W Heavy Duty Fixed Meeting Rail 6063-T6 8 223A 6223W Sash Top 8, Bottom Rail 6063-T6 9 223A 6223W ISash Bottom Rail 6063-T6 . 10 221B 6221BW Sash Side Rail 6063-T6 11 222 6222W Sash Meeting Rail 6063-T6 12 270 6270W Dogbone Reinforcement 6063-T6 13 2785 62785W Sash Stop 6063-T5 20 4060 740808K Meeting Rail Sweep Latch Plug Rigid PVC 21 242 42105W Sash Top Guide (Anti -rack) Rigid PVC 22 227 42114W End Cap Rigid PVC 23 1213 6Q200K .190" X.200" Won Weill. (Frame) Flex PVC 70 24 4056 64066G .187" X.230" Fin Weill. 25 1003C 66601K Bulb Vinyl Wstp. (Sash) Flex PVC 70 26 276C 70275CK Frame Sill Gasket Polyethylene 27 27 3A 70273AK Frame Head Gasket Polyethylene 28 280 70280BK Sash Gaskets Polyethylene 29 7HRKITW Weephole Corer Plastic 30 1096 71095W Sweep Latch Cast Zinc 31 225 42112N Roller Housing & Guide Vinyl 32 226 7BRWHL2 Roller Brass 40 1155 781PQA #8 X 1" QUAD Pn SMS Steel 41 1155-1 701PQX #8 X 1" Sq. Pn. SMS 410 SS 42 781 PSTX #8 X 1" Sq. Pn. Twin Fast SMS 410 SS 43 7BX38PSA #8 X.375" Sq. Pn. SMS Steel 44 1016 7858WW #6 X.625" Ph. Ft. SMS Steel 50 1265.3 712853K Setting Block 3132" X 1/4" X 1" EPDM 51 1267 71267N Setting Block 1/8" X 1/2" X 1" EPDM 52 6DURAK316 Duraseal - 3/16" (IG only 53 6DURAK14 Duraseal - 114' (IG only) 54 1625 61625W 1/8" Bead Aluminum 55 2719 65016W 3/16' Bead Aluminum 56 1263 65133W 1/4" Bead Aluminum 57 1253 6VT48W I.G. Bead Rigid PVC 70 1014 61014FW Screen Frame Aluminum 71 1631 47041 W Screen Comer Key No Ring Vinyl 72 1630 47042W Screen Comer Key with Ring Vinyl 73 320 7320SPNO Screen Spring Spring Steel 74 1624 61624K Screen Spline - .135" Dia. Foam Rubber 75 .1635 61635K Screen Spline - .135" Die. Hard Rubber 76 Screen Cloth Fiberglass , 80 134 60615W Add -on Flange (Optional) 6083-T6 81 Dow Corning 899 Silicone Glazing Sealant or Equiv. 90 1/8" Annealed or Tempered Glass 91 3/16' Annealed.or Tempered Glass 92 114" Annealed or Tempered Glass 93 1/8"- 1/4" Alr - 1/8" An. or Temp. I.G. 94 1/6"- 3/16" Air- 3/16" An. or Temp. I.G. 2.000° 050" 1.827" E 1 .050" - 11-+- -- 2.00V' ,87G" 2.824" .062" .062" 2.428" 'J_ .052" OFRAME HEAD O FRAME SILL 6063-T6ALUMINUM 6083-T5 ALUMINUM �+-- 1.662° 1.662° oez" - OFIXED MEETING RAIL 6063-T6 ALUMINUM r1.115" 1 .062" 12 DOGBONE REINFORCEMENT. 6083-T6 ALUMINUM 1.642" .062" - 2.124" SILL ADAPTER 40 FRAME JAMB (FIXED) 6063-T6 ALUMINUM 6063-T6 ALUMINUM r- 1.815" 050" -� .062" 2.010" .926" .093" .062' - .093" 1.605' 1.OG2° HD F O DE RAIL 6 63-T6 ALUMINUM RAIL O6 63 T6 ALUMINUMSASH TOP & OM RAIL 10 6063 T6SASH IALUMINUM 1.114" .7e811" L 13 SASH STOP 6063-T5 ALUMINUM 11- 1.187" r .050" .050'� ADDON FLANGE 80 6063-T6 ALUMINUM 5g105 No w_ QD FLO OP •��` ,���� 1070 TECHNOLOGY DRIVE "-••••'a`•. ��� N. VENICE, FL 34275 P.O. BX O1529 FL NO34274 A. LYNN MILLER, P.E. P.E.#b8705 CERT. OF AUTH. j/29296 Revlsron: BOM & PART DETAILS .062" 2.209" 0 FRAME JAMB(OPERABLE�'r^�7 6063-T5 ALUMINUM ) r1.749" �I 1.457" ,082" 1 11 SASH MEETING RAIL 6063-T6 ALUMINUM Approved w complying will,lite Frorida ppa0din Code Dn1e Q4/GSB20 Z iV0 - ► . o¢ rani onlml. By� RNe: HORIZONTAL ROLLER V412OWDETAILS Selves/Model: Scoie; Sheet: Drawing N' HR-210 NTS 8 OF 8 MD-H J ROSOWSKI Dole; 12/01 /11 Rev. R210-01 I j Planning & Development Services Building & Code Regulation Division Permitting Department 2300 Virginia Avenue Fort Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 Review Comments PROPERTY INFORMATION Address: 19 SIERRA DEL NORTE City / State / Zip: FORT PIERCE FL 34951 Parcel # : 1301-111-0001-000/5 Jurisdiction: St. Lucie County Zoning: PUD Lot # : Block: APPLICATION INFORMATION Permit Number: 1301-0011 Activity Type: Other Permit Type: Building (Miscellaneous) CONTRACTOR INFORMATION Contractor Name: JACKMAN, JEFFREY T Business Name: MASTER CRAFTALUMINUM PRODUCTS Business Addr: 1634 SE NIEMEYER CIRCLE City / State / Zir PORT ST LUCIE, FL 349E Page 1 Owner(s): WYNNE BUILDING CORP Application Type: Building Permit w/o subs Other Activity: ALUMINUM STRUCTURE Stories: 1 Automatic Sprinkler System? ❑ REVIEWS AND COMMENTS Review Tvpe Status Reviewed By Documents Missing Pending Angela Huff 01/03/2013 1 Comment NOTICE OF COMMENCEMENT Front Counter Review Complete Angela Huff Fax Number 772-335-0860 Date Started Date Complete Date Released 01/03/2013 Plans Examiner Review Incomplete Joe Cicio 01/23/2013 01/23/2013 1 Comment ON THE BUILDING INFORMATION SHEET YOU HAVE DESIGNED TO 150 M.P.H. WINDSPEED AND A RISK CATEGORY II' THIS CATEGORY IS WOULD REQUIRE THIS STRUCTURE TO BE DESIGNED TO 160 M.P.H. WINDSPEED 01/23/2013 2 Comment COMMENT FAXED TO CONTRACTOR AS OF THIS DATE To Be Reviewed by Zoning Complete To Be Review by Plans Exan Complete . 01/03/2013 Joe Cicio 01/23/2013 01/23/2013 TRANSMISSION VERIFICATION REPORT TIME 01/21/2013 19:14 NAME SLC CODE COMP FAX 7724626448 TEL 7724622963 SER.# BROE5J278861 DATE,TIME- 01/21 19:14 FAX NO./NAME 93350860 DURATION 00:00:21 PAGE(S) 01 RESULT OK MODE STANDARD ECM I Planning & Development Services Building & Code Regulation Division Permitting Department 2300 Virginia Avenue Fort Pierce, FL 34982 Phone: (772) 462.1553 Fax: (772) 462-1573 P140PERTY INFCtRMATCQ11l Address: 19 SIERRA DEL NORTE City I State I Zip: FORT PIERCE Parcel # : 1301-111-0001.00015 Zoning: PUD APPLICATION INFORMAT_IQI� Permit Number. 1301.0011 Activity Type: Other Permit Type: Building (MisoellanOOW Review Comments FL 34951 Jurisdiction: St, Lucie County Lot # : Block: CONTRACTOR INFORMATION Contractor Name: JACKMAN. JEFFREYT Business Name: MASTER CRAFT ALUMINUM PRODUCTS BusinessAddr: 1634 SE NIEMEYER CIRCLE Page 1 Owner(s): WYNNE BUILDING CORP Application Type: Building Permit w/o subs OtherActivlty: ALUMINUM STRUCTURE Stories: 1 Automatic Sprinkler System? El Fax Number 772.335.0860 City 1 state I Zit PORT ST LUGIE, FL 349! REvteM AND COMMENTS ReyiewTYpe Status Reviewed BK Documents Missing Pending Angela Huff Data Started DateCumplete Dace Released 01l031201$ 1 Commeni NOTICE OF COMMENCEMENT ,{. —I- U.." ndM9113nA7 r � I �- os ru c u re \ \ \ 8'11-1/4" Cat III sunroom under '\\ existing truss roof and CBS Home structure \ \ \ \ 3 o' LF1 Sol, 610-1/2" 1 x 3 and 2 x 3 attachment to host structure see detail c2-4 ao 4-12 Scale: 1/4" =1' CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBU Y OF THE CONUTOROMRD H\ Sr ctu \\\ \ \ \ \ 33 \ \ \ \ 24" IGCkpl2fe 24° 19 fate- \ ...... ....... ........ ..... L_Ji _ J�JI Upright to concrete See Detail C-1-4 Wag THESE PLANS AND ALL PROPOSED WORK ST. LUCIE COU TY DIN ARE SUBJECT TO ANY CORRECTIONS eUI EVE DI oN REQUIRED BY FIELD INSPECTORS THAT P 1 c MAY sE NECESSARY IN ORDER TOWED BY DATE • .2 GOMMYWIT14 44 r PEICABL-ECQDE& PLANS ND PER IT MUST BE PT ON JOB OR NO INSPECTION WILL BE MADE Windows and Doors HR210 Horizontal Slider PGT FL#242.1 0LO Custom Windows/Guardian o a 24"16ekplat 24"IGcl�late. 24"IGcl�late ' V ; E LL ga,�'; --- - Hinged Door �, V ��ZU 9,a„ FL#161.1 Front Si -de Cf) 0 Elevation Kickers @ 2' OC added for extra support electrical, and kickplate backin Sheet # Site Address:19 Sierra del Norte, Spanish Lakes Country Club 1 Design Criteria: Cat III Sunroom, Velocitv Zone: 150 MPH. Emosure B Of 1