Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSDATE: T FEES DUE:ti� 4, p 0 1 RECEIPT #: T C ,1-3 0:, I Permit #: _0035 1. Location/Site Address: Planning & Development Services Department Building & Code Regulation Division 2300 Virginia Avenue Ft. Pierce, FL 34982-5652 Tel. 772-462-1553 APPLICATION FOR ROOF PERMIT SEE REVERSE SIDE FOR INSTRUCTIONS 7330 Marsh Terrace 2. Parcel ID Number: 33217804-0040-000-5 St 4Uci@ unty Office Use Only I Section Township Range Map Page Zoning Land Use I itials P U 0 ?"5 3. Description of Project or Work Activity: Re -roof Single Family Residenc 4. Total Roof Area (square feet): 3700 5. Roof Pitch: 6/12 6. Type of Roof: [ ] Fiberglass Shingle [x ] Concrete Roof Tile [ ] Tar & Gravel [ ] Modified Bitumen [ ] Wood Shake / Shingle [ ] Other [ ] Product Approval required for all types of Roofing Material (2 Sets) ] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product Approval attached ** Roof Mitigation per F.S. 553.844 will be required. 7. Owner Information 8. Contractor Information Name: June D'Angelo Address: 7330 Marsh Terrace City: Port St. Lucie State: FL Zip: 34986 Phone: 772-979-0255 9. Value of Construction: $ 18,000.00 FL Reg/Cert #: CCCA17517 County Cert #: 466F- 1r.6'%8 Business Name: Packard Roofing Cell Phone: 772-468-3723 **Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval. CONTRA,CTORIOWNEWS AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in compliance with all a licabl aws regulating construction and zoning. PRINT QUALIFIERS/OWNERS NAME SI A QUALIF R STATE OF FLORIDA, COUNTY OF71-1 C L - C P ACKNOWLEDGED BEFORE ME THIS 1-7 DAY OF TV('d?eM I/llf 2d l , BY��C�/ 2� WHO IS PERSONALLY KNOWN L"�TO ME OR HAS PRODUCED Q AS IDENTIFICATION PiiBIdC-STATE OF FWPJDA SIGNATURE OF NOTARY- TYPE OR PRINT NAME OF NOTARY (�"..,• . Stephanie R Smith I Commission # DD902611 COMMISSION NUMBER '•.,, Expires: SEP. 01, 2013 oNDING CO. INC. NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY �1J� PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Revised V26/2010 Planning & Development Servic4s Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 772-462-2165 or 772-462-2172 Fax: 772-462-6443 ROOF INSPECTION AFFIDAVIT Re: Permit# rid 1 _d03S I, C,{V �( �C'(KaLd , licensed as a( Contrac /Engineer/Architect (Please print name & circle license type) *FS468 Building Inspector *General, Building, Residential or Roofing Contractor or any individual certified under 468 F.S. to make such an inspection. On or about ``J0 I I did personally inspect the roof deck nailing (Date) work at: 7T3 0 MQ6(n f r- (Job site address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S.) CCU � 7, —7 Signature and Seal License # STATE OF FLORIDA COUNTY OF Sworn to and su sc4ibed before this V A d�Y of -InIX 20 by(f%� i'"CLC Who is personally known to me or who has produced as identification. XOTARY,Pti BLIC-STATE OF FLORIDA Notary Public, State of FI rida Stephanie P. Smith Signature of Notary ��� . Currimission #DD902671 - F:x-pir' s: SEE 01 2013 Commission Number: (S ;itTr1RCATLA:V'TICBONDING Co..INC En 01/19/2011 JOSEPH E. SMITH, CLERK OF THE CIRCUIT COURT - SAINT LUCIE COUNTY FILE # 3786862 OR BOO. 70 PAGE 2252, Recorded 01/04/2013—11,2:49 PM Permit No. State of Florida County of St. Lucie NOTICE OF COMMENCEMENT Tax Folio No. 3321-804-0040-000-5 The undersigned hereby gives notice that improvement will be made to certain real property, and In accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. L al D ptfon Of Pro (an�t reet addr d avails le): Mrsh�anding a�`�fte Keserve--xlase �ne-Lot 33, 7330 Marsh Terr. General description of improvement: Re -roof Single Family Residence Owner lntopnatior�Iree information if the Lessee contracted for the improvement Name JJLine U PP1lffltgelo Address f33u Marsh i err., YOrt,1. LUGe, t-l- J4Ut1d Interest in property: Fan _SluMpp Name and address of fee simple titleholder (if different from Owner listed above): Contractor's Name: Packard Roofing &Waterproofing, Inc. _ ContractorAddress, 10 eservi a race phone Number.77 8-3= Port St. lucie, FL 34986 Surety (if appllceble, a copy of the payment bond is attached): Amount of bond: $ Name and address: Phone number: Lender Name: Phone Number: Lenders address: Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section L.13(1) (a)7., Florida Statutes: Name: Phone Number: Address: In addition to himself or herself, Owner designates Lienors Notice as provided in Section 713.13(1) (b), Florida Statutes. Phone number of person or entity designated by owner: to receive a copy of the Expiration date of notice of commencement: (the expiration date may not be before the completion of construction and final payment to the contractor, but will be 1 year from the date of recording unless a different date Is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury, I declare that I have read the foregoing notice of commencement and that the facts stated therein are true to the best of my owledge and bell f. (Si ature of Owner or Lessee, orOwner's or Lessee's Authorized Officer/Director/Partner/Manager (Signatory's Title/Office) to The foregoing instrument was acknowledged before me this , day of20 1 By ftJr'� 1'ers n C- % e-) as 0cV✓tQ� for Name of Person Type of authority (e.g. officer, trustee) Party on behalf of whom instrument was executed pif- -� Q Personally known _!!�`or produced Identification_ (Signature of Notary Public - State of Fladda NOTARY PtiBi1CSTATE OF FLORIDA (Print, Type, or Stamp Commissioned Name of Notar�pPttbijc Stephanie P. Smith Commission #DD902671 '. i Expires: SEP. Ol, 2013 BONDED THRO AnVX-11f]D1 Zf£Up t-71, j=jT1rj7 f tj; oy� 09 Type of Identification produced "s PA'e--KA %RI,/V AN 4g1.0 T reas4l� 1 . COPY, Harvey E. Koehnen C oast Professional Engineer #32831 B uilding Architect #AR0009471 E ngineers, Certified General Contractor #CGCO24776 Inc. Contractor pAjcGKAP j2 a,00l: L tJ 4 I h4, Owner V A fA v-_LdU Job Address '7334) m4.gg5a Tsp,• S..LI co. TILE ROOF F-13T -- 6RA t 3" P LNtJ`CArTL00 vTuNT -nL-G_ NEW ROOF RE -ROOF >C REPAIR AREA 370 D 5-t"• TILE ROOF PLAN 7205 Elyse Circle P S L Florida 34952-8212 PHONE(772) 466-5509 FAX(772) 489-3035 E-MAIL:hkoehnen@tcbeweb.com Date ( 2-1Z ol( 2 N A FL 78o4- Rl ■�■■■■■■■!■� ■!!■i■■!!�!!o!l�ioiiiv■lwY�i •■■■■■■■■■■■■■■■■■■■I�■■■■■■■■■■■■■■VA, ■ ■■■■■■ ■a■■■■■■■■■�I■�■■■■■■■■■■■■■■■■w■tw■■ram■ ■■■■■■ . ■■■■■■■■■��[�a■■■■■■■■■■■■■■�■�■■■■■ME ■■■■■■ ni*111■■■■■■■■■±lrF�■■■■■■■■■!1■E■■�r��■ice■is■I \:111■■■■■■■■� ■■■■■■ Dili■■■■■■■■■Cif■�\\■■■■!�\■i■ ■`a■■■■■■■■�■a■■■�■�■�■■■sue■■■■■ ■■ ■■■■■■ ■■■■■■■■■■■ ■■ ■■■■i■ NONE �I■.�■■■�■lbw■■ il�!■■■■■■■�■■R!��i■■■�■idCl■■ Now MEMNON 71rfi)■■■■■■■■■■■�u■■■■■■�\■■�\■\rii■��■� ■■■■■■ �I■■■■■■■■■■i■■�1■■■■■■��\■�!!d\�i■��■i ■i■■■■ MEMNON �!i►r■■■O■:■■■■■■■■■■■�■■■■■■\ i�li■■■■����MENNEN ■■■■■■■■■■■■■■■■■■�■.■.■�■■■■i■�es■■ ■■■■■■ r ----� ■■■■■■ P- 34952-32 "2rs5 Eiy:�L �9ccE ASCE 7-10 & FBC 2010 ENCLOSED BLDG_ S MI ENCLOSED-LD ,< x_. U�EN PART 2 LOW RISE C&C SIMPLIFIED RISK CAT 2 / V 1(so / EXPOSU RE (3 / X Kzt = 1.0 / ROOF / PITCH /12, h ZONE 1 B @ h=30 = x X = PSF x 0.6 ZONE B @ h=30 = xX = PSFx0.6 a ZONE B @ h=30 = xA = PSFx0.6a= !P1 Mp=(PA)-Mg= K• 1 xA Q.20' - IVI041 =Mp I, <Mf= FOAM NOA - • MORTAR NAIL 1^*l0 56t-0w rca I-n 4:0AUG GrMala*�I�.l PADDY SIZE .::WEIGHT NAIL SIZE NUMBER PER TILE RIDGE VENT DCSM FASTENING NAIL TILE FASTENING MORTAR FOAM X DRIP EDGE SIZE._3'(3 DRIP MATERIAL '2 6 AN 41 • FLASHING MATERIAL Z d! A- Avt ' DECK TYPE PLYWOOD THICKNESS 14/32• M>•i0 OTHER BASE SHEET TU PLJJ5 NO. OF PLIES I TYPE OF F#st1di'Et5/BONDING S rut A -VAC-. rL1061 PLY SHEET NO. OF PLIES TYPE OF FASTENERS/BONDING FASTENERS/BONDING: NAILS SELF ADHERING ROOFING NAILS & TINS CAPS FASTENER SPACING FOR ANCHOR/BASE SHEET ATTACHMENT: Field —"oc @ Lap, # Rows- @ _" oc Perimeter: "oc @ Lap, # Rows - @ _ " oc Corner: _ " oc @ Lap, # Rows=@ _" oc .' 11 TRINITY ERD EVALUATION REPORT Entegra Roof Tile, Inc. 1289 NE 9th Avenue Okeechobee, FL 34972 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 Evaluation Report E39310.11.11-1-R1 FL7804-R7 Date of Issuance: 11/02/2011 Revision 1: 06/22/2012 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2010 Florida Building Code (HVHZ) sections noted herein. DESCRIPTION: Entegra Concrete Roof Tiles (HVHZ jurisdictions) LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes; or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinitylERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report -consists of pages 1 through 7. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 HARVEY E. KOE!- HEN _ �i' �jl•✓ Professional Engineer 32831 I 1 7205 Elyse Circle (� Port St. Lucie, FL 34952-3212 (772) 489-3035 fax The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 06/22/2012 This does not serve as an electronically signed document. signed, sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. TrinitylERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. ROOFING SYSTEM EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Roofing Tiles Compliance Statement:. Entegra Concrete Roof Tiles, as produced by Entegra Roof Tile, Inc., have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Code Section Property Standard Year 2007 1523.6.5.2 Physical Properties TAS 112 1995 2007 1523.6.5.2 Wind Driven Rain TAS 100 1995 2007 1523.6.5.2.2 Static Uplift Resistance TAS 101 1995 2007 1523.6.5.2.3 Static Uplift Resistance TAS 102 1995 2007 1523.6.5.2.3 Static Uplift Resistance TAS 102(A) 1995 2010 1523.6.5.2 Physical Properties TAS 112 2011 2010 1523.6.5.2 Wind Driven Rain TAS 100 2011 2010 1523.6.5.2.2 Static Uplift Resistance TAS 101 2011 2010 1523.6.5.2.3 Static Uplift Resistance TAS 102 2011 2010 1523.6.5.2.3 Static Uplift Resistance TAS 102(A) 2011 3. REFERENCES: Entity Examination Reference Date ATL(TST3782) TAS 112 RT0615.01-11 06/28/2011 ATL(TST3782) TAS 112 RT0615.02-11 06/28/2011 ATL(TST3782) TAS 112 RT0615.03-11 06/28/2011 ATL(TST3782) TAS 112 RT0615.04-11 06/28/2011 ATL(TST3782) TAS 112 RT0615.05-11 06/28/2011 Tile Roof Institute TAS 100, TAS 101, 102, 102(A) Membership Confirmation Current PRI (QUA9110) Quality Assurance Service Confirmation 11/02/2011 4. PRODUCT DESCRIPTION: 4.1 BERMUDA FLAT and PLANTATION FLAT are TAS 112, Type 3a (flat -profile) concrete roof tiles. I 16• J 10• v Bermuda Flat Exterior Research and Design, LLC. Certificate of Authorization #9503 -16 Plantation Flat Evaluation Report E39310.11.11-1-111 FL7804-R7 Revision 1: 06/22/2012 Page 2 of 7 .2 •.3 .3 fTRINITY ERD ESTATE "S" are TAS 112, Type lb (interlockinq, low -profile) concrete roof tiles. :king, high -profile) concrete roof tiles. 1n-interlocking, high -profile) concrete roof tiles. LIMITATIONS: 5.1 This Evaluation Report is for use in FBC HVHZ jurisdictions or other jurisdictions adopting FBC HVHZ requirements. 5 2 Fire classification is not part of this evaluation; refer to FBC Section 1516 or current Approved Roofing Materials Directory for fire rating of this product. 513 Reference is made to FBC Section 1512.4.2.4 regarding field testing of completed tile roof 1installations. 54 Applicant shall retain the services of an FBC listed, accredited laboratory to perform quarterly tests in accordance with TAS 112, Appendix W. Such testing shall be submitted to TrinityJERD for review. Research and Design, LLC. Evaluation Report E39310.11.11-1-Ri a of Authorization #9503 FL7804-117 Revision 1: 06/22/2012 Page 3 of 7 it TRINI-N ERQ 5.5 Minimum underlayment shall comply with the RAS 118, RAS 119 or RAS 120, as applicable. Underlayment products shall hold Florida Statewide Product Approval or Local Approval for use in tile roof assemblies in HVHZ jurisdictions. 5.6 Minimum roof deck requirements shall be in accordance with applicable FBC HVHZ requirements. 5.8 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C. Rule 9N-3. 6. INSTALLATION: 6.1 Entegra Concrete Roof Tiles may be mechanically fastened, mortar -set or adhesive -set. Installation shall comply with manufacturer's current published instructions, but not less than the requirements of RAS 118, RAS 119 or RAS 120, as applicable. 6.2 Attachment Calculations: Entegra Concrete Roof Tile shall be evaluated as a Moment -Based System' in accordance with RAS 127-95 (for 2007 Code) or RAS 127-11 (for 2010 Code) using the data outlined herein. Table 1: Aerodynamic Multipliers - A, (ft3) Tile Batten Application Direct -Deck Application Bermuda Flat 0.189 0.205 Plantation Flat 0.267 0.289 Bella High "S" 0.349 0.378 Estate "S" 0.267 0.289 Galena Spanish "S" N/A 0.235 Table 2: Restoring Moment due to Gravity -Mg (ft-lbf) Roof Slope (0) Tile 2:12<0<3:12 3:12<0<4:12 4:12<0<5:12 5:12<0<6:12 6:12<0<7:12 0>7:12 Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Bermuda Flat 5.22 6A3 5.17 6.37 5.09 6.27 4.98 6.15 4.86 6.00 4.72 5.83 Plantation Flat ; 7.22 7.91 6.85 7.79 6.75 7.67 6.61 7.52 6.44 7.32 V 6.26 7.04 Bella High "S" 6.19 6.89 6.11 6.80 5.99 6.67 5.85 6.51 5.68 6.33 5.50 6.13 Estate "S" 6.14 6.84 5.91 6.74 5.82 6.64 5.70 6.50 5.56 6.33 5.40 6.14 Galena Spanish "S" N/A 1 6.20 N/A 6.13 N/A 6.03 N/A 5.89 N/A 5.74 N/A 5.57 Exterior Research and Design, LLC. Evaluation Report E39310.11.11-1-Ri Certificate of Authorization #9503 FL7804-117 Revision 1: 06/22/2012 Page 4 of 7 ' TRINITY; ERD Table 3A-1: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) Flat Profile Tiles, echanical y Attached Systems Tile Fastener Direct -Deck (min.15/32" plywood) Direct -Deck (min.19/32" plywood) Battens Type yp # Size Shank Clip p Nail One (1) 10d Smooth or Screw N/A 7.3 9.8 4.9 Nail Two (2) 10d Smooth or Screw N/A 14.0 18.8 7.4 Nail One (1) SOd Smooth or Screw Eave v 19.0 19.0 22.1 Nail One (1) u lod I/ Smooth or Screw Field 24.3 24.3 24.2 �t Nail Two (2) 10d Smooth or Screw Eave 31.9 31.9 32.2 6r Plantation Nail Two (2) 10d Smooth or Screw Field 35.5 35.5 34.8 Flat Nail Two (2) 10d Ring N/A 30.9 38.1 17.2 Nail' Two (2)' 10d' Ring' N/A 50.3' 65.5' 48.31 Screw One (1) #8 N/A N/A 30.8 30.8 18.2 Screw Two (2) 1 #8 N/A N/A 51.7 51.7 24.4 1 Installation with a 4-inch tile headlap and fasteners located min. 2Y inch from head of tile. Table 3A-2: Attachment Resistance Expressed as a Moment-Mf (ft-lbf) Flat Profile Tiles, Adhesive -Set Systems Size (inch) Weight (g) TO Substrate To Tile TO Substrate XToeMf Tile Application Adhesive (ft-lbf) TILE BOND- 1 x 6 1 x 6 10.4 10.4 40.6 Touch 'n Seal- StormBond 1.25 x 10 1.25 x 8 8 10.2 73.2 3M Foam Roof Tile Inter- Bermuda Flat Dependent dhesive RTA-1(formerly 4 x 8 4 x 8 12 12 51.8 or Plantation P set° One) 3M 2- mponent Foam Flat Roof Tile hesive AH-160 4 x 4Xx 16 8 31.3 (formerly Pol o° AH160) 3M 2-Component oam 2 x 7 N/A 24 N/A 40.4 Independent Roof TiileAdhesive A 60 (formerly PolyPro° AH1N1 2 0 N/A 45 N/A 118.9 Table 36-1: Attachment R3srstan'ekExpressed as a Moment- Mf (ft-lbf) Low Profile es, Mecha ' ally Attached Systems Tile Fa ner Direct -Deck (min.1S/32" plywood) Direct -Deck (min.19/32" plywood) Battens Type # Sze Shank Clip Nail One (1)2 10d Smooth or Screw N/A 8.92 11.8, 4.12 Nail Two 10d Smooth or Screw N/A 16.4 21.9 7.1 Nail e(1)2 30d Smooth or Screw Eave 19.0, 19.0, 22.12 Nail One(1)2 10d Smooth or Screw Field 2 2 24.32 2.4.22 Nail Two (2) 30d Smooth or Screw Eave 31.9 31.9 32.2 "S" N Two (2) 30d Smooth or Screw Field 35.5 35.5 34.8 Estate Nail Two (2) 30d Ring N/A 27.8 N.Z7.4 28.8 Nail' Two (2)' 10d' Ring' N/A 43.0 67. 50.91 Screw One (1) #8 N/A N/A 25.82 25.82 22.92 Screw Two (2) #8 N/A N/A 47.1 47.1 49.1 1Intallation with a 4-inch tile headlap and fasteners located min. 2X: inch from head of tile. 2 For one (1) fastener installations, utilize hole that is approximately 4Winch from the interlocking edge. Exterior Research and Design, LLC. Evaluation Report E3931O.11.11-1-Ri Certificate of Authorization #9503 FL7804-117 Revision 1: 06/22/2012 Page 5 of 7 l !TRINITY ERa 7. LABELING: 7.1 Each unit shall bear the imprint or identifiable marking of the manufacturer's name or logo, as detailed below. Tile lots shall be labeled in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. E N T E G R��� � 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Okeechobee, FL 10. QUALITY ASSURANCE ENTITY: PRI Construction Materials Technologies, LLC. — QUA9110; (813) 621-5777 - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report E39310.11.11-1-R1 Certificate of Authorization #9503 FL7804-117 Revision 1: 06/12/2012 Page 7 of 7 �* EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 .,f TRINITY' ERD OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 EVALUATION REPORT Polyglass USA, Inc. Evaluation Report P12060.02.09-1111 150 Lyon Drive F1-5259-1116 Fernley, NV 98408 Date of Issuance: 02/24/2009 Revision 11: 08/17/2012 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2010 Florida Building Code sections noted herein. DESCRIPTION: Polyglass Roof Underlayments LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 10. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 08/17/2012 This does not serve as an electronically signed document. Signed, sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client t 0 I ttv Iti CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity[ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. r-� `TRINITY I ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.3, 1507.3.3, 1507.5.3, Physical Properties ASTM D226 2006 1507.7.3 1507.8.3 1507.9.3 1507.2.4, 1507.2.9.2, 1507.3.3, Physical Properties ASTM D1970 2001 1507.11.2 Physical Properties ASTM D6164 2005 1507.11.2 Physical Properties ASTM D6222 2002 1504.6 Accelerated Weathering ASTM G154 2005 1504.6 Accelerated Weathering ASTM G155 2005 1504.3.1 Wind Uplift FM 4474 2004 1507.3.3 Installation Practice FRSA/TRI 07320 2005 1523.6.5.2.1 Physical Properties TAS 103 1995 3. REFERENCES: Entity Examination Reference Date FM Approvals (TST 1867) Wind Uplift 3004091 01/12/2000 PRI (TST 5878) Physical Properties PRI01111 04/08/2002 PRI (TST 5878) Physical Properties PUSA-005-02-01 01/31/2002 PRI (TST 5878) Physical Properties PUSA-013-02-01 12/23/2002 PRI (TST 5878) Physical Properties PUSA-013-02-02 12/23/2002 PRI (TST 5878) Physical Properties PUSA-013-02-03 12/23/2002 PRI (TST 5878) Physical Properties PUSA-018-02-01 07/14/2003 PRI (TST 5878) Physical Properties PUSA-028-02-01 07/13/2005 PRI (TST 5878) Physical Properties PUSA-033-02-01 01/12/2006 PRI (TST 5878) Physical Properties PUSA-035-02-01 09/29/2006 PRI (TST 5878) Physical Properties PUSA-055-02-02 12/10/2007 PRI (TST 5878) Physical Properties PUSA-061-02-02 01/28/2008 PRI (TST 5878) Physical Properties PUSA-076-02-01 02/22/2008 PRI (TST 5878) Physical Properties PUSA-083-02-01 04/14/2008 PRI (TST 5878) Physical Properties PUSA-088-02-01 07/29/2009 MTI (TST 2508) Physical Properties JX20H7A 04/01/2008 MTI (TST 2508) Physical Properties RX14E8A 01/29/2009 ERD (TST 6049) Physical Properties 11752.09.99-1 02/08/2000 ERD (TST 6049) Wind Uplift 11776.06.02 01/16/2003 ERD (TST 6049) Physical Properties 02200.07.03 07/14/2003 ERD (TST 6049) Wind Uplift P1740.01.07 01/04/2007 ERD (TST 6049) Physical Properties P5110.04.07-1 04/11/2007 ERD (TST 6049) Wind Uplift P9260.03.08 03/21/2008 ERD (TST 6049) Physical Properties P13450.08.09 08/13/2009 ERD (TST 6049) Wind Uplift P30540.11.09-R1 11/30/2009 ERD (TST 6049) Physical Properties P33360.06.10 06/25/2010 Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R11 Certificate of Authorization #9503 FL5259-11116 Revision 11: 08/17/2012 Page 2 of 10 Entity ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ICC-ES (EVL 2396) Miami -Dade (CER 1592) Polyglass USA Polyglass USA Polyglass USA UL, LLC. (QUA9625) r \J TRINITY I ERD Examination Reference Date Physical Properties P33370.03.11 03/02/2011 Physical Properties P33370.04.11 04/26/2011 Physical Properties P40390.08.12-1 08/06/2012 Physical Properties P40390.08.12-2 08/07/2012 IBC Compliance ESR-1697 11/01/2011 HVHZ Compliance NOA Current Manufacturing Affidavit Products Current 02/18/2009 P/L Affidavit Mule -Hide Cross Ltg 03/01/2008 Materials Affidavit Polystick SA Compound 08/18/2011 Quality Control Service Confirmation Exp. 08/08/2015 4. PRODlechanically DESCRIPTION: 4.1 Fastened Underlayments: 4.1.1 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet. 4.1.2 Elastobase P is a polyester -reinforced, SBS modified bitumen base sheet. 4.2 Self -Adhering Underlayments: 4.2.1 Polystick MTS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced with polyolefinic film surface; meets ASTM D1970 and TAS 103. 4.2.2 Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an aggregate surface; meets ASTM D1970. 4.2.3 Polystick TU is a nominal 100-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a granular surface; meets ASTM D1970 and TAS 103. 4.2.4 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a polyester fabric surface; meets ASTM D1970 and TAS 103. 4.2.5 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass- fiber/polyester reinforced, with a granular surface; meets ASTM D1970 and TAS 103. 4.2.6 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 170 g/m2 polyester fabric surface; meets TAS 103. 4.2.7 Polyflex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) are a polyester reinforced, APP modified bitumen cap sheets. 4.2.8 Dual PrOTM is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface. 4.2.9 Tile PrOT" is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface. 4.3 Mechanically Fastened and/or Bonded Underlayments: 4.3.1 Elastoflex S6G and Elastoflex S6G FR are polyester reinforced, SIBS modified bitumen cap sheets. 4.3.2 Polyflex G and Polyflex G FR are polyester reinforced, APP modified bitumen cap sheets. 5. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVHZ. 5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1111 Certificate of Authorization #9503 FL5259-1116 Revision 11: 08/17/2012 Page 3 of 10 I TRINITY I ERD 5.3 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the AHJ for approval based on this evaluation combined with supporting data for the prepared roof covering. 54 Allowable roof covers aDDlied atOD the underla ments are as follows: Table 1: Roof Cover Options Wood Underlayment Asphalt Shingles Nail -On Tile Foam -On Tile Metal Shakes & Slate Shingles Elastobase Yes Yes No Yes Yes Yes Elastobase P Yes Yes No Yes Yes Yes Polystick MTS Yes Yes No Yes Yes Yes Polystick IR-Xe Yes No No No Yes Yes Polystick TU Yes Yes See Yes 5.Polystick No Yes Yes TU P Yes Yes Yes See 5.4.1 No Yes Yes PolystickTUPlus Yes Yes See Yes 5.PolystickTU Yes Yes Yes Max No Yes See Yes 5.Dual No No No Pro Yes Yes No Yes Yes Yes Tile Pro Yes Yes See es 5.Elastoflex Yes Yes Yes S6G or S6G FR Yes Yes No No Yes Yes Polyflex G or G FR Yes Yes Yes See 5.4.1 No Yes Yes Polyflex SAP or SAP FR Yes Yes Yes See 5.4.1 No Yes Yes Mule -Hide SA-APP Cap Sheet Yes Yes Yes No Yes Yes or SA-APP Cap Sheet (FR) See 5.4.1 5.4.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives unless tensile adhesion / long term aging data from an accredited testing laboratory is provided. ➢ Polyfoam PolyPro AH160: Polystick TU, Polystick TU P, Polystick TU Plus, Polyflex G, Polyflex G FR, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule - Hide SA-APP Cap Sheet (FR) or Tile Pro. ➢ 3MTm 2-Component Roof Tile Adhesive AH-160: Polystick TU Max ➢ Dow TileBond: Polystick TU P, Polystick TU Plus, Polyflex SAP or Tile Pro 5.4.2 For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the tile. 5.4.3 A 2-ply underlayment system, consisting of Polystick MTS followed by Polystick MTS, TU, TU P, TU Plus or TU Max, or Polyflex SAP is allowable for use under mechanically attached prepared roof systems. This is not a requirement, but is allowable if a 2-ply underlayment system is desired. Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R11 Certificate of Authorization #9503 FL5259-1116 Revision 11: 08/17/2012 Page 4 of 10 i TRINITY ERD 5.5 Allowable substrates are noted below: 5.5.1 Direct -Bond to Deck: Polystick, Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: ➢ New untreated plywood; ➢ ASTM D41 primed new untreated plywood; ➢ Existing plywood; ➢ ASTM D41 primed existing plywood; ➢ ASTM D41 primed OSB; ➢ Southern Yellow Pine; ➢ ASTM D41 primed Southern Yellow Pine; ➢ ASTM D41 primed structural concrete; ➢ Huber Engineered Woods "ZIP System" Panels (designed and installed to meet wind loads for project). Note: Polyglass does not require priming of new or existing plywood sheathing. New or existing plywood sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes. Elastoflex S6G or S6G FR in hot asphalt to: ➢ ASTM D41 primed structural concrete. Polyflex G or G FR torch -applied to: ➢ ASTM D41 primed structural concrete. 5.5.2 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI 07320 does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI 07320 and are used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609.1.5 for determination of design wind pressures. 5.5.2.1 Maximum Design Pressure = -622.5 psf. Deck: Structural concrete to meet project requirements to satisfaction of AHJ. Primer: ASTM D41 Underlayment: Polyflex G or G FR torch -applied. 5.5.2.2 Maximum Design Pressure = -315 psf. Deck: Structural concrete to meet project requirements to satisfaction of AHJ. Primer: ASTM D41 Underlayment: Polystick TU, Polystick TU P, Polystick TU Plus, Polystick TU Max, Tile Pro, Polyflex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR). 5.5.2.3 Maximum Design Pressure = -135 psf. Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ. Primer: (Optional) ASTM D41 Joints: Min. 4-inch wide strips of Elastoflex SA-V over all plywood joints. Underlayment: Polystick TU, Polystick TU P, Polystick TU Plus, Polyflex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1111 Certificate of Authorization #9503 FL5259-1116 Revision 11: 08/17/2012 Page 5of10 i � _y TRINITY ERD 5.5.2.4 Maximum Design Pressure = -90 psf. Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ. Primer: (Optional) ASTM D41 Underlayment: Polystick TU, Polystick TU P, Polystick TU Plus, Polyflex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) 5.5.2.5 All other direct -deck, adhered Polyglass underlayment systems beneath foam -on the systems carry a Maximum Design Pressure of -45 psf. 5.5.3 Bond -to -Insulation: ➢ Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered . to: ASTM C1289, Type II, Class 1 polyisocyanu rate or Type V polyisocyanurate-composite insulation; DensDeck DuraGuard; DensDeck Prime; or SECUROCK Gypsum -Fiber Roof Board. ➢ Elastoflex S6G or S6G FR in hot asphalt to: DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board. ➢ Polyflex G or G FR torch -applied to: ASTM D41 primed structural concrete; DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval.. For installations under foam -on tile systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4470, Appendix K or TAS 114, Appendix J. 5.5.4 Bond to Mechanically Attached Base Layer: ➢ Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or Tile Pro self -adhered to: ASTM D226, Type I or II felt; Elastobase; Elastobase P or Mule -Hide Nail Base. ➢ Elastoflex S6G or S6G FR in hot asphalt to: ASTM D226, Type I or II felt; Elastobase; Elastobase P or Mule -Hide Nail Base. ➢ Polyflex G or G FR torch -applied to: Elastobase; Elastobase P or Mule -Hide Nail Base. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam -on tile systems, base layer shall be attached per minimum requirements of FRSA/TRI 07320/8-05 or RAS 120. 5.6 Exposure Limitations: 5.6.1 Elastobase, Elastobase P, shall not be left exposed for longer than 30-days after installation. 5.6.2 Polystick IR-Xe, Polystick TU Max, Dual Pro or Tile Pro shall not be left exposed for longer than 90-days after installation. 5.6.3 Polystick MTS, TU, TU P or TU Plus shall not be left exposed for longer than 180-days after installation. 5.6.4 Polyflex SAP or SAP FR, or Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure limitation, unless the prepared roof covering is to be adhesive -set tile, in which case the maximum exposure is 30 days. 5.6.5 Elastoflex S6G or S6G FR or Polyflex G or G FR does not have an exposure limitation, unless the prepared roof covering is to be adhesive -set tile (Polyflex G or G FR only), in which case the maximum exposure is 180 days. Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1111 Certificate of Authorization #9503 FL5259-1116 Revision 11: 08/17/2012 Page 6 of 10 \', TRINITY �-R/ INITY ERA 5.7 For tile roof installations governed by the FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, use is limited to the following. Reference is made to the FRSA/TRI Technical Brief titled "Florida High Wind Roof Tile Self -Adhered Underlayment Requirements as of 02/14/2011" for limitations for self -adhering underlayments used beneath tile roof systems. Table 2: Tile System Options per FRSA/TRI 07320/8-05 System Underlay Option Section Reference Product(s) 3.02A 1 Batten Modified Cap Sheet Elastoflex S6G or Elastoflex S6G FR; Polyflex G or G FR only No. 30 / Modified Cap Base Layer: Elastobase; Elastobase P System One: 2 3.026 Sheet Top Layer: Elastoflex S6G or Elastoflex S6G FR; Polyflex G Mechanically or G FR Fastened Tile, 4 3.0213 No. 30 Elastobase; Elastobase P Unsealed or Sealed Self -Adhered ✓ ol st Pick MTS; TU; TU P; TU Plus; TU Max; Polyflex SAP or Underlayment 5 3.02E Underlayment Ale -Hide SA-APP ap Sheet or SA-APP Cap Sheet (FR); Dual Pro; Tile Pro System Base Layer: ASTM D226, Type II; Elastobase; Elastobase P; No. 30 / Self -Adhered Mule -Hide Nail Base 6 3.02F Underlayment Top Layer: Polystick MTS; TU; TU P; TU Plus; TU Max; Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA- APP Cap Sheet (FR); Dual Pro; Tile Pro 3.02A 1 Batten Modified Cap Sheet Elastoflex S6G or Elastoflex S6G FR; Polyflex G or G FR only No. 30 / Modified Cap Base Layer: Elastobase; Elastobase P System Two: 2 3.02B Sheet Top Layer: Elastoflex S6G or Elastoflex S6G FR; Polyflex G Mechanically or G FR Fastened Tile, Self -Adhered Polystick TU; TU P; TU Plus; TU Max; Polyflex SAP or SAP Sealed 4 3.02D Underlayment FR; Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet Underlayment (FR); Dual Pro; Tile Pro System Base Layer: ASTM D226, Type II; Elastobase; Elastobase P; No. 30 / Self -Adhered Mule -Hide Nail Base 5 3.02E Underlayment Top Layer: Polystick TU; TU P; TU Plus; TU Max; Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro; Tile Pro 1 3.02A Modified Cap Sheet Polyflex G or G FR 2 3.02B No. 30 / Modified Cap Base Layer: Elastobase; Elastobase P System Four Sheet Top Layer: Polyflex G or G FR �A": Self -Adhered Polystick TU; TU P; TU Plus; TU Max yflex SAP or SAP Adhesive -Set 3.02D Underlayment FR; Tile Pro; Mule -Hide SA -AP p Sheet or SA-APP Cap Tile, Unsealed or Sheet (FR) Sealed Base Layer: AS 226, Type II; Elastobase; Elastobase P; Underlayment Mule -Hid Base System 5 3.02E No. 30 / Self -Adhered erlayment T ts—yer: Polystick TU; TU P; TU Plus; TU Max; Polyflex SAP or SAP FR; Tile Pro; Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) No. 30 odified Base Layer: ASTM D226, Type II; Elastobase; Elastobase P 1 3.02A Layer: Polyflex G or G FR System Four Self -Adhered Polysti ; TU P; TU Plus; TU Max; Polyflex SAP or SAP B"": 3 .02C Underlayment FR; Tile Pro; -Hide SA-APP Cap Sheet or SA-APP Cap Adhesive -Set Sheet (FR) Tile, Sealed Base Layer: ASTM D226, Typ Elastobase; Elastobase P; Underlayment Mule -Hide Nail Base System 4 3.02D No. 30 / Self -Adhered Underlayment Top Layer: Polystick TU; TU P; TU Plus; ax; Polyflex SAP or SAP FR; Tile Pro; Mule -Hide SA-APP C heet or SA-APP Cap Sheet (FR) Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1111 Certificate of Authorization #9503 FL5259-1116 Revision 11: 08/17/2012 Page 7 of 10 � TRINITYIERD 6. INSTALLATION: 6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 Elastobase, Elastobase P or Mule -Hide Nail_ Base: 6.3.1 Shall be installed in compliance with the codified requirements for ASTM D226, Type II underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.3.2 For use in non -tile applications: 6.3.2.1 Reference is made to the current edition of the NRCA Steep -slope Roofing Manual and ARMA recommendations for installing shingle underlayments and flashings 6.3.2.2 Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), Dual Pro or Tile Pro, self -adhered, Elastoflex S6G or S6G FR in hot asphalt or Polyflex G or G FR, torch applied. 6.3.3 For use in tile applications, reference is made to Polyglass published installation instructions in conjunction with FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein. 6.4 Polystick MTS IR-Xe TU TU P TU Plus, TU Max Polyflex SAP or SAP FR, Mule -Hide SA-APP Ca[) Sheet or SA-APP Ca[) Sheet (FR) Dual Pro or Tile Pro: 6.4.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.4.2 For non -tile applications: 6.4.2.1 All self -adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) should be back -nailed in selvage edge seam in accordance with Polyglass / Mule -Hide Back Nailing Guide. Nails shall be corrosion resistant, 11 gauge ring -shank type with a minimum 1-inch diameter metal disk or Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back - nailed using the above noted fasteners and spacing, in area marked "nail area, area para clavar" on the face of membrane. The head lap membrane is to cover the area being back - nailed 6.4.2.2 All seal -lap seams (selvage laps) must be firmly rolled with a minimum 28 lb. hand roller to ensure full contact and adhesion. For Dual Pro and Tile Pro, align the edge of the top sheet to the end of the glue pattern (the sheet will overlap the fabric). Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1111 Certificate of Authorization #9503 F1_5259-1116 Revision 11: 08/17/2012 Page 8 of 10 JTIRINITYIERD View of Ovelap Seam of Dual Pro and Tile Pro 6.4.2.3 All over -fabric and over -granule end -laps shall have a 6-inch wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Polystick TU Plus Tile Underlayment Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Electrometric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic, applied in between the application of the lap. 6.4.2.4 Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details 6.4.2.5 Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Polystick TU Plus Tile Underlayment Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic to the area in need of repair, followed by a minimum 6 x 6 inch patch of the Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be installed in a water shedding manner. 6.4.2.6 All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a minimum of 40-lb weighted -roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied for the field membrane. Hand rollers are acceptable for rolling of patches, laps (min. 28 lb roller) or small areas of the roof that are not accessible to a large roller or broom. 6.4.3 For tile applications (not allowed for Polystick IR-Xe): 6.4.3.1 Reference is made to Section 6.4.2 herein in conjunction with FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein, using the instructions noted above as a guideline. 6.4.3.2 For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the tile. Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R11 Certificate of Authorization #9503 FL5259-1116 Revision 11: 08/17/2012 Page 9 of 10 ice.\ ")OTRINITY 6.5 Elastoflex S6G or S6G FR: 6.5.1 E toflex S6G or S6G FR shall be installed in compliance with current Pol lass published inst ation requirements. For use in nail -on the applications, reference is ade to FRSA/TRI 0732\n3 5 Installation Manual, Fourth Edition, and Table 2 herein. 6.5.2 Elasto6G or S6G FR shall be fully asphalt -applied to the substra s noted in Section 5.5. Side lII be minimum 3-inch and end -laps minimum 6-inch ide, and off set end -laps minimfe from course to course. Side and end laps shall b fully adhered in a complete moppf hot phalt with asphalt extending approximately 3 -inch beyond the lap edge. 6.6 Polvfor G F . 6.6.1 Polyflor G FR shal a installed in compliance with c rent Polyglass published installation requits. For use in tile applications, refer ce is made •FRSA/TRI 07320/8-05 InstalManual, Fourth ition, and Table 2 her6.6.2 Polyflor G FR shall be ful asphalt -applied o the substrates noted in Section 5.5. Side laps be minimum 3-inch nd end -lap minimum 6-inch wide, and off set end -laps minim3 feet from course to c urse. de and end laps shall be fully heat -welded and inspeo ensure minimum 3/8-in fl of modified compound beyond the lap edge. 6.7 Tile Staging: 6.7.1 Tile shall be loaded and staged i manne that prevents tile slippage and/or damage to the underlayment. Refer to Polygl s published r uirements for the staging.. 6.7.2 Battens and/or Counter-ba ens, as required by a the manufacturer and FRSA/TRI 07320/8- 05 must be used on all of slopes greater than 12. For roof slopes in excess of 61/4:12, precautions should be aken, such as the use of ba ens, to prevent tile sliding during the loading process. 6.7.3 For nail -on the s stems over Polystick MTS, battens are req 'red for loading / staging of the tile. 6.7.4 The minimu cure time after installation of self -adhering membran s and before loading of roofing tiles is forty-eight (48) hours. 7. LABELING: Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL, LLC - QUA9625; (314) 578-3406; k.chancellor@us.ul.com - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R11 Certificate of Authorization #9503 FL5259-1136 Revision 11: 08/17/2012 Page 10 of 10 T reasure Harvey E. Koehnen C oast Professional Engineer #32831 B u i Id i ng Architect #AR0009471 E ngineers, Certified General Contractor #CGCO24776 Inc. These "Cables Are For Roof Coverings Roof coverings Installed on Buildings with a Mean Roof Height of 30' or Less Located in Exposures B, C or D Table R301.2 [21_oR -Ainx54 Q5c fF 7- lb COMPONENTS AND CLADDING WORST CASE DESIGN PRESSURE [PSF]. (�S� 160 Exp C 160 Exp C 160 Exp D 160 Exp D (One story (Two story*) (One story*) (Two story Roof > 0 to 7 degrees Zone 1 -27.6 -33.4 -38.7 -40.6 -45.9 7degrees = 11/2 /12 pitch Zone 2 -46.4 -56.2 -65.0 -68.3 -77.1 Zone 3 -69.8 -84.5 -97.7 -102.7 -115.9 Roof > 7 to 27 degrees 'Zone 1 -26.3 - 30,7 - 35.5 -37.2 - 42 27 degrees = 6/12 pitch Zone 2 -44,1 - 53.4 - 61.8 -64.9 - 73.3 Zone 3 -65.1 -78.8 - 91.2 - 95.7 - 108:1 Roof > 27 to 45 degrees Zone 1 - 27.8 -33.7 -40.0 -40.1 -46:2 45 d..egrees = 12/12 pitch Zone 2 - 32.4 -39.3 -45.4 -47.7 -53.8 Zone 3 - 32.4 -39.3 -45.4 - 47,7 -53.8 160 Exp S 150 Exp C 150 Exp C 150 Exp D 150 Exp D (one story*) ( two story*) (one story*) ( two story) Roof > 0 to 7 degrees Zone 1 -24.3 -29.6 -34.1 -35.8 -40.4 7degrees = 11/2 /12 pitch Zone 2 -40.8 -49.4 -57.2 -60.0 -67.8 Zone 3 -61.4 -74.3 -86.0 -90.3 -102.0 Roof > 7 to 27 degrees Zone 1 -22,2 - 26.9 - 31.1 -32.7 - 36.9 27 degrees = 6/12 pitch Zone 2 -38.7 . - 46.9 - 54.2 -56.9 - 64.3 Zone 3 . -57,3 - 69.4 - 80.3 -84.3 - 95.2 Roof > 27 to 45 degrees Zone 1 - 24.3 =29.5 -34.1 -35.8 -40.4 . 45 degrees = 12/12 pitch Zone 2 - 28.4 34.4 -39.8 -41.8 -47.2 Zone 3 - 28.4 -34.4 -39.B -41.8 -47.2 \xi 11'� One story* = one story building with a maximum mean roof height of 15 feet Two story* = two story building with a maximum mean roof height of 30 feet -if allowed by the Miami Dade N.O.A or Florida Product Approval ., any -system-that does not meet the minimum components and cladding pressures for the area that the building is located per this form may require a Florida licensed engineer to revise the fastener spacing T C B E, Inc. 7205 Elyse Circle PHONE (772) 466-5509 Port Saint Lucie FAX (772) 489-3035 Florida 34952-8212 E-MAIL hkoehnen@tcbeweb.com WEB SITE htto://www.tcbeweb.com