HomeMy WebLinkAboutSUBMITTED PAPERSDATE: 1
FEES DUE: i3 IiA , d RECEIPT #: �q 3 ~� Permit #: )3 0
Planning & Development Services Department
Building & Code Regulation Division
2300 Virginia AvenueFt. Pierce, FL 34982-5652
@No
Tel.772-462-1553 St LU, BY
APPLICATIONISEE EFOR ROOFSAE FOR PERMITCie Couf7t
1. Location/Site Address: 7gro I�e Iykt oe- 't� y
2. Parcel ID Number: -(00C -0U0-c1(0-(
Office Use
Only
Section
Township
Range
Map Page
Zoning
Land Use
Initials
3. Description of Project or Work Activity: f -fpO
4. Total Roof Area (square feet): 30 00 5. Roof Pitch: Z
6. Type of Roof: [ *Fiberglass Shingle [ ] Concrete Roof Tile [ ] Wood Shake / Shingle
[ ] Tar & Gravel [ ] Modified Bitumen [ ] Other
[ ] Product Approval required for all types of Roofing Material (2 Sets)
] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product
Approval attached
** Roof Mitigation per F.S. 553.844 will be required
7. Owner Information 8•
Name: Nci C"J 4J
Address: r)'01 \�R. \Vu ov\j k
City: U W(e_ State: 'F�
Zip: Phone:- 5175- 15_ L�
9. Value of Construction: $ 9cloc)
Contractor Information
j I, Reg/Cert #:
County Cert #: L) O O 5
Business Name:-
Cell Phone: Q [S Q (o
"Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval.
CONTRACTOR(OWNER'S AFFIDAVIT: I certify
done in
PRINT ALIFIERS/OWNERS NAME
STATE OF FLORIDA, COUNTY OF Sk . L v c �y,
ACKNOWLEDGED BEFORE ME THIS DAY OF Ja h ' 20 13 , BY '36V%V% U%% „- 64,-Lt
` WHO IS PERSONALLY KNOWN TO MEOR HAS PRODUCED V-tlL A 2J5 -4 a i'kd6 %AS IDENTIFICATION
1�-�Ouw+w. 4� 4 w+ne► �1'� -V t T,,-s
SIGNATURE OF NOTARY TYPE OR PRINT NAME OF NOTARY (seal)
COMMISSION NUMBER 1;'96 4 r041 4 1
NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PA
FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
Revised 4/26/2010
all of the information contained in this application is correct and that all
)liance with all applicable laws regulating construction and zoning.
OF QUALIFIER/OWNER
NG�
Z L
C7Z�W o
v'GCZ
C 10 `;
o�' E H,o
E E~
a. U
'.E m
INSTRUCTIONS
Please complete all information in the space provided. All information must be printed (use black or blue ink
only) or typed. This roof permit application is to be used only for those activities that are not otherwise included
under a primary building permit. This application may not be used for any activity that includes structural
alteration. Building, activities involving structural alteration, in addition to the roof work, must be permitted
through the regular building permit review process. The information to be provided with this application
includes:
1. Location/Site Address
2. Parcel ID Number
3. Description of Project or Work Activity
4. Total Roof Area
5. Type of Roof
6. Owner Information
7. Contractor Information
8. Value of Construction
Indicate the street address or general location of the
property where the building activity is taking place.
Indicate the tax identification number of the property where
the building activity is taking place.
Completely describe the building activity to take place.
Please indicate if tear -off or shingle over shingle etc.
Indicate total roof area to be affected by this permit. Also
indicate the pitch of the roof, expressed as a standard ratio
of run rise.
Indicate the type of roof being repaired or resurfaced.
Indicate the name and address of the owner of the property
on which building activity is taking place. ,
Indicate the State of Florida registration number (if
applicable), St. Lucie County contractor license number and
the name of the business doing the work.
Indicate the total value of the work to take place. Total cost
of construction includes all material and labor costs
associated with the building/construction activity.
Construction value is used to determine the permit fee. St..
Lucie County reserves the right to question and/or modify
the indicated value of construction if it is demonstrated that
the submitted "figures are not consistent with similar types
of construction.
ion can be submitted to St. Lucie County Building and. Zoning, 2300 Virginia Avenue, Fort Pierce,
11 permit applications must be filled out completely before submission. No applications will be
processing after 4:30 P.M. For assistance fi completing this application, please call (772)
firing regular office hours (8:00 AM - 5:00 PM), Monday through Friday.
of this permit, required inspections can be scheduled by calling (772) 462-1261.
Permit Application rev. 3/1/2009
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34982
772-462-2165 or 772-462-2172
Fax: 772-462-6443
ROOF INSPECTION AFFIDAVIT
Re: Permit # 13 Off` 003 rP
1, \IOAJ licensed as a(n)Contractor*/Engineer/Architect
(Please print name & circle license type) *FS468 Building Inspector
*General, Building, Residential or Roofing Contractor or any individual certified under 468 F.S. to make such an inspection.
On or about I- ) 8 W* , I did personally inspect the roof deck nailing
(Date) 7 1 Pwte,
workat: ' 1n`'-2 \q0( MONi Ave-�yA- F l 3`19 l
(Job site address)
Based upon that examination I have determined the installation was done according to the Hurricane
Mitigation Retrofit Manual (Based on 553.844 F.S.)
CCC -bs
License #
STATE OF FLORIDA
COUNTY OF 53W-.1^O C. fir.
Sworn to and subscribed before me this LVk�tl day of S4y1 2013
by'Tay% Who is personally known to me or who has produced.
lrL D #1 7lS 1 - 4i7 19^d°►4-o as identification.
Notary Public, State of Florida
Signature of Notary: 11.
Commission Number: if- 4 5% 1 S;1 (Seal)
En 01/19/2011
OEANNA GIVENS
Notary Public - State of Florida
+ My Comm. Expires 0et 16, 2016
•• •o'= Commission #EE g5876A
OF F�Bonded Through National Notaryssn.
���4np1�
JOSEPH E. SMITH, CLERK OF THE CIRCUIT COURT - SAINT LUCIE COUNTY
FILE # 3786864 OilY0OK 3470 PAGE 2254, Recorded '1/04/2013 at 01:00
NOTICE OF COMMENCEMENT
Permit No. Tax Follo No.
State of Florida County of St. Lucie
The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes,
the following information is provided In this Notice of Commencement.
General description of
Owner Infor�a�tlon cir Lessp�e informs ion If the Lessee contracted for the improvement:
me 1 Y\ Nar r Y�rS
Address 9To( wAnv vw*. F\
Interest in property: 0Lv#jP/"
Name and address of fee simple titleholder (if different from Owner listed above):
Contractor's Name:
Contractor Address:
Phone Number:
Surety (if applicable, a copy of the payment bond Is attached): Amount of bond: $
Name and address: Phone number:
Lender Name: _
Lender's address:
Number:
Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section
713.13 (11(a)7., Florida Statutes:
Name: Phone Number:
In addition to himself or herself, Owner designates
Lienor's Notice as provided In Section 713.13(1) (b), Florida Statutes.
Phone number of person or entity designated by owner:
to receive a copy of the
Expiration date of notice of commencement: (the expiration date may not be before the completion of construction and final payment to the
contractor, but will be 1 year from the date of recording unless a different date is specified)
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED
IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY, A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IFYOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR
RECORDING YOUR NOTICE OF COMMENCEMENT.
Under penalty of perjury, I declare that I have read the foregoing notice of commencement and that the facts stated therein are true to the best of
my knowledge and belief.
(Sigrt4ure of Owner op1�essee, or Owners or Lessee's Authorized Officer/Director/Partner/Manager
,oti�Y Pf,4Rebecca Lynn Hessler
SI nato ?(YJMMISSION#EE090605
(g NsTtle/Office )EXPIRES: MAY04,2015
'%;�;�'d^^^ ww,v.AARonNorN(tam
The foregoing Instrumentwas acknowledged before me this day of 20� ,
By `W as 0 W (J it for
a of P rson Type of authority (e.g. officer, trustee) Party on behalf of whom Instrument was executed
1
Personally known or produced Identification_.
(Signa of Notary Public-Stta 90ftorida
(Print, or Stamp Commisslorfed3�iame of Notary Public) Type of Identification produced
%Ilo oY. • . .:A�. :.mm
STATE of FLORIDA
PT ( uCIF COUNTY
DFiLE COPY
QOTRRINITYIERD
EVALUATION REPORT
Polyglass USA, Inc.
150 Lyon Drive
Fernley, NV 98408
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
Evaluation Report P12060.02.09-R11
FL5259-R16
Date of Issuance: 02/24/2009
Revision 11: 08/17/2012
SCOPE:
This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing
the use of construction materials in the State of Florida. The documentation submitted has been
reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and
Florida Building Code, Residential Volume. The products described herein have been designed to
comply with the 2010 Florida Building Code sections noted herein.
DESCRIPTION: Polyglass Roof Underlayments
LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality
Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)
changes, the referenced Quality Assurance documentation changes, or provisions of the Code that
relate to the product change. Acceptance of this Evaluation Report by the named client constitutes
agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality
Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation
Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may
be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it
shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by
the manufacturer or its distributors and shall be available for inspection at the job site at the
request of the Building Official.
This Evaluation Report consists of pages 1 through 10.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized
by Robert Nieminen, P.E. on 08/17/2012
This does not serve as an electronically signed
document. Signed, sealed hardcopies have been
transmitted to the Product Approval Administrator and
to the named client
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which
the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
\.I TRINITY I ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have
demonstrated compliance with the following sections of the Florida Building Code through testing in
accordance with the following Standards. Compliance is subject to the Installation Requirements and
Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1507.2.3, 1507.3.3, 1507.5.3,
1507.7.3, 1507.8.3, 1507.9.3
Physical Properties
ASTM D226
2006
1507.2.4, 1507.2.9.2, 1507.3.3,
1507.5.3
Physical Properties
ASTM D1970
2001
1507.11.2
Physical Properties
ASTM D6164
2005
1507.11.2
Physical Properties
ASTM D6222
2002
1504.6
Accelerated Weathering
ASTM G154
2005
1504.6
Accelerated Weathering
ASTM G155
2005
1504.3.1
Wind Uplift
FM 4474
2004
1507.3.3
Installation Practice
FRSA/TRI 07320
2005
1523.6.5.2.1
Physical Properties
TAS 103
1995
3. REFERENCES:
Entily
Examination
Reference
Date
FM Approvals (TST 1867)
Wind Uplift
3004091
01/12/2000
PRI (TST 5878)
Physical Properties
PRI01111
04/08/2002
PRI (TST 5878)
Physical Properties
PUSA-005-02-01
01/31/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-01
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-02
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-03
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-018-02-01
07/14/2003
PRI (TST 5878)
Physical Properties
PUSA-028-02-01
07/13/2005
PRI (TST 5878)
Physical Properties
PUSA-033-02-01
01/12/2006
PRI (TST 5878)
Physical Properties
PUSA-035-02-01
09/29/2006
PRI (TST 5878)
Physical Properties
PUSA-055-02-02
12/10/2007
PRI (TST 5878)
Physical Properties
PUSA-061-02-02
01/28/2008
PRI (TST 5878)
Physical Properties
PUSA-076-02-01
02/22/2008
PRI (TST 5878)
Physical Properties
PUSA-083-02-01
04/14/2008
PRI (TST 5878)
Physical Properties
PUSA-088-02-01
07/29/2009
MTI (TST 2508)
Physical Properties
JX20H7A
04/01/2008
MTI (TST 2508)
Physical Properties
RX14E8A
01/29/2009
ERD (TST 6049)
Physical Properties
11752.09.99-1
02/08/2000
ERD (TST 6049)
Wind Uplift
11776.06.02
01/16/2003
ERD (TST 6049)
Physical Properties
02200.07.03
07/14/2003
ERD (TST 6049)
Wind Uplift
P1740.01.07
01/04/2007
ERD (TST 6049)
Physical Properties
P5110.04.07-1
04/11/2007
ERD (TST 6049)
Wind Uplift
P9260.03.08
03/21/2008
ERD (TST 6049)
Physical Properties
P13450.08.09
08/13/2009
ERD (TST 6049)
Wind Uplift
P30540.11.09-Ri
11/30/2009
ERD (TST 6049)
Physical Properties
P33360.06.10
06/25/2010
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-11111
Certificate of Authorization #9503 FLS2S9-R16
Revision 11: 08/17/2012
Page 2 of 10
i
��TRIN,rryIERD
Entity Examination Reference Date
ERD (TST 6049) Physical Properties P33370.03.11 03/02/2011
ERD (TST 6049) Physical Properties P33370.04.11 04/26/2011
ERD (TST 6049) Physical Properties P40390.08.12-1 08/06/2012
ERD (TST 6049) Physical Properties P40390.08.12-2 08/07/2012
ICC-ES (EVL 2396) IBC Compliance ESR-1697 11/01/2011
Miami -Dade (CER 1592) HVHZ Compliance NOA Current
Polyglass USA Manufacturing Affidavit Products Current 02/18/2009
Polyglass USA P/L Affidavit Mule -Hide Cross Ltg 03/01/2008
Polyglass USA Materials Affidavit Polystick SA Compound 08/18/2011
UL, LLC. (QUA9625) Quality Control Service Confirmation Exp. 08/08/2015
4. PRODUCT DESCRIPTION:
4.1 Mechanically Fastened Underlavments:
4.1.1 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet.
4.1.2 Elastobase P is a polyester -reinforced, SBS modified bitumen base sheet.
4.2 Self -Adhering Underlavments:
4.2.1 Polystick MTS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber
reinforced, surfaced with polyolefinic film surface; meets ASTM D1970 and TAS 103.
4.2.2 Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass
fiber reinforced, with an aggregate surface; meets ASTM D1970.
4.2.3 Polystick TU is a nominal 100-mil thick rubberized asphalt waterproofing membrane, glass fiber
reinforced, with a granular surface; meets ASTM D1970 and TAS 103.
4.2.4 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane, glass
fiber reinforced, with a polyester fabric surface; meets ASTM D1970 and TAS 103.
4.2.5 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-
fiber/polyester reinforced, with a granular surface; meets ASTM D1970 and TAS 103.
4.2.6 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a
170 g/m2 polyester fabric surface; meets TAS 103.
4.2.7 Polyflex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet
(FR) are a polyester reinforced, APP modified bitumen cap sheets.
4.2.8 Dual Prom is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane,
fiberglass reinforced, with a polyester fabric surface.
4.2.9 Tile PrOTM is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane,
fiberglass reinforced, with a polyester fabric surface.
4.3 Mechanically Fastened and/or Bonded Underlavments•
4.3.1 Elastoflex S6G and Elastoflex S6G FR are polyester reinforced, SBS modified bitumen cap
sheets.
4.3.2 Polyflex G and Polyflex G FR are polyester reinforced, APP modified bitumen cap sheets.
5. LIMITATIONS:
5.1 This Evaluation Report is not for use in the HVHZ.
5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing
Materials Directory for fire ratings of this product.
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-RII
Certificate of Authorization #9503 FL5259-R16
Revision 11: 08/17/2012
Page 3 of 10
TRINITY J ERD
5.3 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is
specifically referenced within FBC approval documents. If not listed, a request may be made
to the AHJ for approval based on this evaluation combined with supporting data for the
prepared roof covering.
5.4 Allowable roof covers applied atop the underla ments are as follows:
Table 1: Roof Cover Options
Underlayment
Asphalt
Mail -On Tile
Foam -On
Metal
Wood
Shakes &
Slate
Shingles
Tile
Shingles
Elastobase
Yes
Yes
No
Yes
Yes
Yes
Elastobase P
Yes
Yes
No
Yes
Yes
Yes
Polystick MTS
Yes
Yes
No
Yes
Yes
Yes
Polystick IR-Xe
Yes
No
No
No
Yes
Yes
Polystick TU
Yes
Yes
es
No
Yes
Yes
See
5.Polystick
TU P
Yes
Yes
See es
5.Polystick
No
Yes
Yes
TU Plus
Yes
Yes
See es
5.Polystick
Yes
Yes
Yes
TU Max
No
Yes
es
No
No
No
See
5.Dual
Pro
Yes
Yes
No
Yes
Yes
Yes
Tile Pro
Yes
Yes
es
Yes
Yes
Yes
See
5.Elastoflex
S6G or S6G FR
Yes
Yes
No
No
Yes
Yes
Polyflex G or G FR
Yes
Yes
es
No
Yes
Yes
See
5.Polyflex
SAP or SAP FR
Yes
Yes
Yes
No
Yes
Yes
See 5.4.1
Mule -Hide SA-APP Cap Sheet
Yes
Yes
Yes
No
Yes
Yes
or SA-APP Cap Sheet (FR)
See 5.4.1
5.4.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives unless tensile
adhesion / long term aging data from an accredited testing laboratory is provided.
➢ Polyfoam PolyPro AH160: Polystick TU, Polystick TU P, Polystick TU Pius, Polyflex G,
Polyflex G FR, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -
Hide SA-APP Cap Sheet (FR) or Tile Pro.
➢ 3MTm 2-Component Roof Tile Adhesive AH-160: Polystick TU Max
➢ Dow TileBond: Polystick TU P, Polystick TU Plus, Polyflex SAP or Tile Pro
5.4.2 For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the
tile.
5.4.3 A 2-ply underlayment system, consisting of Polystick MTS followed by Polystick MTS, TU, TU
P, TU Plus or TU Max, or Polyflex SAP is allowable for use under mechanically attached
prepared roof systems. This is not a requirement, but is allowable if a 2-ply underlayment
system is desired.
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R31
Certificate of Authorization #9503 FL5259-R16
Revision 11: 08/17/2012
Page 4 of 10
TRINITY' ERD
5.5 Allowable substrates are noted below:
5.5.1 Direct -Bond to Deck:
Polystick, Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP
Cap Sheet (FR) self -adhered to:
➢ New untreated plywood;
➢ ASTM D41 primed new untreated plywood;
➢ Existing plywood;
➢ ASTM D41 primed existing plywood;
➢ ASTM D41 primed OSB;
➢ Southern Yellow Pine;
➢ ASTM D41 primed Southern Yellow Pine;
➢ ASTM D41 primed structural concrete;
➢ Huber Engineered Woods "ZIP System" Panels (designed and installed to meet wind loads
for project).
Note: Polyglass does not require priming of new or existing plywood sheathing. New or
existing plywood sheathing should be cleaned of all dirt and debris prior to application of
Polystick membranes.
Elastoflex S6G or S6G FR in hot asphalt to:
➢ ASTM D41 primed structural concrete.
Polyflex G or G FR torch -applied to:
➢ ASTM D41 primed structural concrete.
5.5.2 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI 07320
does not address wind uplift resistance of all underlayment systems beneath foam -on tile
systems, where the underlayment forms part of the load -path. The following wind uplift
limitations apply to underlayment systems that are not addressed in FRSA/TRI 07320 and are
used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind
load resistance based on allowable wind loads. Refer to FBC 1609.1.5 for determination of
design wind pressures.
5.5.2.1 Maximum Design Pressure = -622.5 psf.
Deck: Structural concrete to meet project requirements to satisfaction of AHJ.
Primer: ASTM D41
Underlayment: Polyflex G or G FR torch -applied.
5.5.2.2 Maximum Design Pressure = -315 psf.
Deck: Structural concrete to meet project requirements to satisfaction of AHJ.
Primer: ASTM D41
Underlayment: Polystick TU, Polystick TU P, Polystick TU Plus, Polystick TU Max, Tile Pro,
Polyflex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide
SA-APP Cap Sheet (FR).
5.5.2.3 Maximum Design Pressure = -135 psf.
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Primer: (Optional) ASTM D41
Joints: Min. 4-inch wide strips of Elastoflex SA-V over all plywood joints.
Underlayment: Polystick TU, Polystick TU P, Polystick TU Plus, Polyflex SAP, PolyFlex SAP FR,
Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR)
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1111
Certificate of Authorization #9503 FL5259-1116
Revision 11: 08/17/2012
Page 5of10
F)o
,JI RINI1i I ERD
5.5.2.4 Maximum Design Pressure = -90 psf.
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Primer: (Optional) ASTM D41
Underlayment: Polystick TU, Polystick TU P, Polystick TU Plus, Polyflex SAP, PolyFlex SAP FR,
Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR)
5.5.2.5 All other direct -deck, adhered Polyglass underlayment systems beneath foam -on tile systems
carry a Maximum Design Pressure of -45 psf.
5.5.3 Bond -to -Insulation:
➢ Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR)
self -adhered to: ASTM C1289, Type II, Class 1 polyisocya nu rate or Type V
polyisocyanurate-composite insulation; DensDeck DuraGuard; DensDeck Prime; or
SECUROCK Gypsum -Fiber Roof Board.
➢ Elastoflex S6G or S6G FR in hot asphalt to: DensDeck Prime or SECUROCK Gypsum -Fiber
Roof Board.
➢ Polyflex G or G FR torch -applied to: ASTM D41 primed structural concrete; DensDeck
Prime or SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be
attached per minimum requirements of the prepared roof covering manufacturer's Product
Approval. For installations under foam -on tile systems, insulation attachment shall be
designed by a qualified design professional and installed based on testing of the
insulation/underlayment system in accordance with FM 4470, Appendix K or TAS 114,
Appendix J.
5.5.4 Bond to Mechanically Attached Base Layer:
➢ Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR)
Dual Pro or Tile Pro self -adhered to: ASTM D226, Type I or II felt; Elastobase; Elastobase
P or Mule -Hide Nail Base.
➢ Elastoflex S6G or S6G FR in hot asphalt to: ASTM D226, Type I or II felt; Elastobase;
Elastobase P or Mule -Hide Nail Base.
➢ Polyflex G or G FR torch -applied to: Elastobase; Elastobase P or Mule -Hide Nail Base.
For installations under mechanically attached prepared roof coverings, base layer shall be
attached per minimum codified requirements. For installations under foam -on tile systems,
base layer shall be attached per minimum requirements of FRSA/TRI 07320/8-05 or RAS 120.
5.6 Exposure Limitations:
5.6.1 Elastobase, Elastobase P, shall not be left exposed for longer than 30-days after installation.
5.6.2 Polystick IR-Xe, Polystick TU Max, Dual Pro or Tile Pro shall not be left exposed for longer than
90-days after installation.
5.6.3 Polystick MTS, TU, TU P or TU Plus shall not be left exposed for longer than 180-days after
installation.
5.6.4 Polyflex SAP or SAP FR, or Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not
have an exposure limitation, unless the prepared roof covering is to be adhesive -set tile, in
which case the maximum exposure is 30 days.
5.6.5 Elastoflex S6G or S6G FR or Polyflex G or G FR does not have an exposure limitation, unless
the prepared roof covering is to be adhesive -set tile (Polyflex G or G FR only), in which case
the maximum exposure is 180 days.
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-Rii
Certificate of Authorization #9503 FL5259-1116
Revision 11: 08/17/2012
Page 6 of 10
QOTRINITYIERD
5.7 For tile roof installations governed by the FRSA/TRI 07320/8-05 Installation Manual, Fourth
Edition, use is limited to the following. Reference is made to the FRSA/TRI Technical Brief
titled "Florida High Wind Roof Tile Self -Adhered Underlayment Requirements as of
02/14/2011" for limitations for self -adhering underlayments used beneath tile roof systems.
Table 2: Tile System Options per FRSA/TRI 07320/8-05
System
Underlay
Option
Section
Reference
Product(s)
3.02A
1
Batten
Modified Cap Sheet
Elastoflex S6G or Elastoflex S6G FR; Polyflex G or G FR
only
No. 30 / Modified Cap
Base Layer: Elastobase; Elastobase P
System One:
2
3.02B
Sheet
Top Layer: Elastoflex S6G or Elastoflex S6G FR; Polyflex G
Mechanically
or FR
Fastened Tile,
4
3.0213
No. 30
Elastobase; Elastobase P
Unsealed or
Self -Adhered
Polystick MTS; TU; TU P; TU Plus; TU Max; Polyflex SAP or
Sealed
5
3.02E
Underlayment
SAP FR; Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet
Underlayment
(FR); Dual Pro; Tile Pro
System
Base Layer: ASTM D226, Type II; Elastobase; Elastobase P;
No. 30 / Self -Adhered
Mule -Hide Nail Base
6
3.02F
Underlayment
Top Layer: Polystick MTS; TU; TU P; TU Plus; TU Max;
Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-
APP Cap Sheet (FR); Dual Pro; Tile Pro
3.02A
1
Batten
Modified Cap Sheet
Elastoflex S6G or Elastoflex S6G FR; Polyflex G or G FR
only
No. 30 / Modified Cap
Base Layer: Elastobase; Elastobase P
System Two:
2
3.02B
Sheet
Top Layer: Elastoflex S6G or Elastoflex S6G FR; Polyflex G
Mechanically
or G FR
Fastened Tile,
Self -Adhered
Polystick TU • TU P; TU Plus; TU Max; Polyflex SAP or SAP
Sealed
4
3.02D
Underlayment
FR; Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet
Underlayment
(FR); Dual Pro; Tile Pro
System
Base Layer: ASTM D226, Type II; Elastobase; Elastobase P;
No. 30 / Self -Adhered
Mule -Hide Nail Base
5
3.02E
Underlayment
Top Layer: Polystick TU; TU P; TU Plus; TU Max; Polyflex
SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap
Sheet (FR) Dual Pro; Tile Pro
1
3.02A
Modified Cap Sheet
Polyflex G or G FR
2
3.02B
No. 30 / Modified Cap
Base Layer: Elastobase; Elastobase P
System Four
Sheet
Top Layer: Polyflex G or G FR
A..:
Self -Adhered
Polystick TU; TU P; TU Plus; TU Max; Polyflex SAP or SAP
Adhesive -Set
4
3.02D
Underlayment
FR; Tile Pro; Mule -Hide SA-APP Cap Sheet or SA-APP Cap
Tile, Unsealed or
Sheet (FR)
Sealed
Base Layer: ASTM D226, Type II; Elastobase; Elastobase P;
Underlayment
Mule -Hide Nail Base
System
5
3.02E
No. / Self -Adhered
Underlayment
Top Layer: Polystick TU; TU P; TU Plus; TU Max; Polyflex
SAP or SAP FR; Tile Pro; Mule -Hide SA-APP Cap Sheet or
SA-APP Cap Sheet (FR)
1
3.02A
No. 30 / Modified Cap
Base Layer: ASTM D226, Type II; Elastobase; Elastobase P
Sheet
Top Layer: Polyflex G or G FR
System Four
Self -Adhered
Polystick TU; TU P; TU Plus; TU Max; Polyflex SAP or SAP
"B"":
3
3.02C
Underlayment
FR; Tile Pro; Mule -Hide SA-APP Cap Sheet or SA-APP Cap
Adhesive -Set
Sheet(FR)
Tile, Sealed
Base Layer: ASTM D226, Type II; Elastobase; Elastobase P;
Underlayment
Mule -Hide Nail Base
System
4
3.021)
No. 30 / Self -Adhered
Underlayment
Top Layer: Polystick TU; TU P; TU Plus; TU Max; Polyflex
SAP or SAP FR; Tile Pro; Mule -Hide SA-APP Cap Sheet or
SA-APP Cap Sheet (FR)
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1111
Certifcate of Authorization #9503 FL5259-R16
Revision 11: 08/17/2012
Page 7 of 10
QOTRINI-rYIERD
6. INSTALLATION:
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published
installation requirements subject to the Limitations set forth in Section .5 herein and the
specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the
substrate thoroughly to remove any dust and debris prior to application, and prime the
substrate (if applicable).
6.3 Elastobase. Elastobase P or Mule -Hide Nail Base:
6.3.1 Shall be installed in compliance with the codified requirements for ASTM D226, Type II
underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed.
6.3.2 For use in non -tile applications:
6.3.2.1 Reference is made to the current edition of the NRCA Steep -slope Roofing Manual and ARMA
recommendations for installing shingle underlayments and flashings
6.3.2.2 Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick,
Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), Dual Pro or
Tile Pro, self -adhered, Elastoflex S6G or S6G FR in hot asphalt or Polyflex G or G FR, torch
applied.
6.3.3 For use in tile applications, reference is made to Polyglass published installation instructions in
conjunction with FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2
herein.
6.4 Polystick MTS, IR-Xe, TU, TU P, TU Plus, TU Max Polyflex SAP or SAP FR, Mule -Hide
SA-APP Cap Sheet or SA-APP CaD Sheet (FRI, Dual Pro or Tile Pro:
6.4.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment
in FBC Sections 1507 for the type of prepared roof covering to be installed.
6.4.2 For non -tile applications:
6.4.2.1 All self -adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR
and Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) should be back -nailed in selvage
edge seam in accordance with Polyglass / Mule -Hide Back Nailing Guide. Nails shall be
corrosion resistant, 11 gauge ring -shank type with a minimum 1-inch diameter metal disk or
Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back -
nailed using the above noted fasteners and spacing, in area marked "nail area, area para
clavar" on the face of membrane. The head lap membrane is to cover the area being back -
nailed
6.4.2.2 All seal -lap seams (selvage laps) must be firmly rolled with a minimum 28 lb. hand roller to
ensure full contact and adhesion. For Dual Pro and Tile Pro, align the edge of the top sheet to
the end of the glue pattern (the sheet will overlap the fabric).
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1111
Certificate of Authorization #9503 F1_5259-1116
Revision 11: 08/17/2012
Page 8 of 10
1
View of Ovelap Seam of Dual Pro and Tile Pro
`J I UNITY I ERD
6.4.2.3 All over -fabric and over -granule end -laps shall have a 6-inch wide, uniform layer of Polyglass
Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing
Cement, Polyglass PG500 MB Flashing Cement, Polystick TU Plus Tile Underlayment Flashing
Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry
Electrometric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade
mastic, applied in between the application of the lap.
6.4.2.4 Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as
crickets, exposed valleys, or exposed roof to wall details
6.4.2.5 Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55
Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement,
Polyglass PG500 MB Flashing Cement, Polystick TU Plus Tile Underlayment Flashing Cement,
Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry
Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade
mastic to the area in need of repair, followed by a minimum 6 x 6 inch patch of the Polystick
material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed,
shall be installed in a water shedding manner.
6.4.2.6 All Polystick membranes shall be installed to ensure full contact with approved substrates.
Polyglass requires a minimum of 40-lb weighted -roller or, on steep slopes, use of a stiff
broom with approximately 40-lbs of load applied for the field membrane. Hand rollers are
acceptable for rolling of patches, laps (min. 28 lb roller) or small areas of the roof that are not
accessible to a large roller or broom.
6.4.3 For tile applications (not allowed for Polystick IR-Xe):
6.4.3.1 Reference is made to Section 6.4.2 herein in conjunction with FRSA/TRI 07320/8-05
Installation Manual, Fourth Edition, and Table 2 herein, using the instructions noted above as
a guideline.
6.4.3.2 For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the
tile.
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1111
Certificate of Authorization #9503 FL5259-1116
Revision 11: 08/17/2012
Page 9 of 10
',J
TRINITY I ERD:
6.5 Elastoflex S6G or S6G FR:
6.5.1 Elastoflex S6G or S6G FR shall be installed in compliance with current Polyglass published
installation requirements. For use in nail -on tile applications, reference is made to FRSA/TRI
07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein.
6.5.2 Elastoflex S6G or S6G FR shall be fully asphalt -applied to the substrates noted in Section 5.5.
Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, and off set end -laps
minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete
mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge.
6.6 Polyflex G or G FR:
6.6.1 Polyflex G or G FR shall be installed in compliance with current Polyglass published installation
requirements. For use in tile applications, reference is made FRSA/TRI 07320/8-05
Installation Manual, Fourth Edition, and Table 2 herein.
6.6.2 Polyflex G or G FR shall be fully asphalt -applied to the substrates noted in Section 5.5. Side
laps shall be minimum 3-inch and end -laps minimum 6-inch wide, and off set end -laps
minimum 3 feet from course to course. Side and end laps shall be fully heat -welded and
inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap edge.
6.7 Tile Staging:
6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment. Refer to Polyglass published requirements for tile staging..
6.7.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TRI 07320/8-
05 must be used on all roof slopes greater than 7:12. For roof slopes in excess of 61/4:12,
precautions should be taken, such as the use of battens, to prevent the sliding during the
loading process.
6.7.3 For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the
tile.
6.7.4 The minimum cure time after installation of self -adhering membranes and before loading of
roofing tiles is forty-eight (48) hours.
7. LABELING:
Each unit shall bear a permanent label with the manufacturer's name, logo; city, state and logo of the
Accredited Quality Assurance Agency noted herein.
S. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the
installation of this product.
9. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C. Rule 9N-3 QA
requirements.
10. QUALITy ASSURANCE ENTITY:
UL, LLC — QUA9625; (314) 578-3406; k.chancellor@us.ul.com
Exterior Research and Design, LLC.
Certificate of Authorization #9503
- END OF EVALUATION REPORT -
Evaluation Report P12060.02.09-R11
FL5259-R16
Revision 11: 08/17/2012
Page 10 of 10
E] FILE Co"'PY
QOTRRINITYIERD
EVALUATION REPORT
Owens Cor ing
ne Owens Corning Parkway -
Toledo, OH 43659
EXTERIOR RESEARCH & D.ESIGN,, LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX.;. (203). 262-9243_
Evaluation Report 037940.02.12-111
FL10674-R7
Date of Issuance: 02/06/2012
Revision 1: 08/22/2012
SCOPE: -
This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing
the use of construction materials in the State of Florida. The documentation submitted has been
reviewed. by Robert Nieminen,. P.E.. for use of the. product_ under the Florida, Building. Code_ and
Florida Building Code, Residential Volume. The products described herein have been designed to
comply with the 2010 FBC and 2010 FBC Residential Volume sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality
Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)
changes, the referenced Quality Assurance documentation changes, or provisions of the Code that
relate to the product change. Acceptance of this Evaluation Report by the named client constitutes
agreement to notify Robert Nieminen, P.E. if the product changes or the referenced- Quality
Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation
Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinityiERD Evaluated" may
be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it
shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by
the manufacturer or its distributors and shall be available for inspection at the job site at the
request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized
by Robert Nieminen, P:E. on 08/22/2012
This does not serve as an electronically signed
document. Signed, sealed hardcopies have been
transmitted to the Product Approval Administrator and
to the named client
CERTIFICATION OF INDEPENDENCE:
1. TrinityiERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. TrinityiERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which
the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
VTRINITY1 TRINITYERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have
demonstrated compliance with the following sections of -the Florida Building Code and Florida- Building
Code, Residential Volume through testing in accordance with the following Standards. Compliance is
subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard
Year
1507.2.5, R905.2.4 Physical Properties ASTM D3462
2007
1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161, Class F
2006
1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158, Class H
2O07
3. REFERENCES:
Entity Examination Reference
Date
UL (CER1739) Physicals & Wind Resistance File R2453, Vol. 3
02/15/2007
UL (TST1740) Physical Properties 06CA20263
04/18/2006
Miami -Dade (CER1592) FBC HVHZ Compliance 07-1116.12
02/14/2008
Miami -Dade (CER1592) FBC HVHZ Compliance 09-0915.12
12/16/2009
Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.09
10/27/2010
Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.10
10/27/2010
Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.08
10/27/2010
Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.07
10/27/2010
Miami -Dade (CER1592) FBC HVHZ Compliance 11-0411.03
06/16/2011
Miami -Dade (CER1592) FBC HVHZ Compliance 11-0919.05
10/13/2011
UL LLC (QUA9625) Quality Control Service Confirmation R2453
Exp. 09/26/2014
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic° and Supreme° are fiberglass reinforced, 3-tab asphalt roof shingles.
4.1.2 Berkshire° are fiberglass reinforced, 4-tab asphalt roof shingles.
4.1.3 Duration°, TruDefinition° Duration°, Duration° Premium Cool, TruDefinition° Duration°
Designer Color Collection, TruDefinition° Oakridge®, Oakridge° and WeatherGuard° HP are
fiberglass reinforced, laminated asphalt roof shingles.
4.2 Berkshire° Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant and WeatherGuard° HP
Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles.
4.3 Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
S. LIMITATIONS:
5.1 This Evaluation Report is not for use in the HVHZ.
5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing
Materials Directory for fire ratings of this product.
5.3 Wind Classification:
Exterior Research and Design, LLC. Evaluation Report 037940.02.12-111
Certificate of Authorization #9503 FL10674=R7
Date of Issuance: 02/06/2012
Revision 1: 08/22/2012
Page 2 of 6
�l TRINITY I ERD
5.3.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables
1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating
the shingles are acceptable for us in all wind zones up to Vasd = 150 mph (V„it = 194 mph).
Refer to Section 6 for installation requirements to meet this wind- rating.
5.3.2 All Owens Corning hip & ridge shingles and Starter Strip Plus noted herein are Classified in
accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating, the
shingles are acceptable for us in all wind zones up to Vasd = 150 mph (V„it = 194 mph). Refer
to Section 6 for installation requirements to meet this wind rating.
5.3.3. Classification- by ASTM. D7158. applies_ to- exposure category B. or C and_ a. buildingheight of 60-
feet or less. Calculations by a qualified design professional are required for conditions outside
these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.3.4 Refer to Owens Corning- published information on wind resistance and installation limitations.
5.4 All products in the roof assembly shall have quality assurance audit in accordance with the
Florida Building Code and F.A.C. Rule 9N-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide
Product Approval,- or be Locally Approved per Rule 9N-3,: per FBC Sections 1507.2.3, 1507.2.4
or R905.2.3.
6.2 Asphalt Shingles:
6.2.1 Installation. of asphalt- shingles_ shalt comply with. the manufacturer's current- published_
instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2
or R905.2, with the following exceptions:
Ber-kshir-e.@ shingles. require minimum- five_ (5.), nails. per shingle..
➢ WeatherGuard° HP shingles require minimum six (6) nails per shingle.
➢ Starter Strip Plus requires minimum five (5) nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less
than FBC 1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of
fastening are required. Contact the shingle manufacturer for details.
6.2.5 Minimum Nailing — Classic@ & Supreme:
Nonnol Mansard or Area porn
WindAreaa High'Wind dosvanesy
Area pare vientoa nmmaies Aroas vientos taerres.
�� (A) �. r�. z• (B
� • �r
ti Exposure
Bsposioi6n
Exterior Research and Design, LLC.
Certificate of Authorization #9503
Normal Mansard or Area porn
Wind Aron* High Wind deavanes y
Ana pars vientos norma,es A►sas viontos fuartes
5 GIs' Exposure
Eaposicidn
Evaluation Report 037940.02.12-111
FL10674-R7
Date of Issuance: 02/06/2012
Revision 1: 08/22/2012
Page 3 of 6
6.2.6 Minimum Nailing - Berkshire@:
Sealant dip
/.La tba de sellader
t' 8w ' 9V I 9YP
�,,! I Rlhll"jYI ERD
Sea6ntstrip.
La Bra de sdk*r
eYt eYf BYf 8Yf
Asphati rooTnpement
Canto de tedro de addle
6.2.7 Minimum Nailing - Duration@, TruDefinition@ Duration, Duration@ Premium Cool &
TruDefinition° Duration° Designer Color Collection:
4 Nail Pattern
Esquema de 4.Clavos
' uUrq alptastenmgarea vwdth
Area dodawsSbreNaUO
t. t.
1T 12
67O"Exposure Nails' SW 6gwsare
6'h putz & elwaod6n Cbybs. W pulg. de exposkkin
xansar0an0 Steep Sbp�
6 pattern
awaeetaemSted.
Pattern armanatop Neuted.
do 6davos ° al
...._ ...�_ heaSuref7ai>rbpsb -
a�iordereurt.
SunBaia \ •,SvepaiP
ffiteNrr99 Arade 65tmrf99
anauaID � armMmh
r
sun iz
5V Exposure- Nails. 5w Exposure
5ebpdg.deo"16n C(avoS 5r%pu(g..doaxpos(d6n
6.2.$ Minimum Nailing - TruDefinition® Oakridge@, Oakridge@.:.
4 Nail Panora
Squema con 4 davos
66f8"Fvmre Nam SliffEgposure
Ezposldunde66/8ptd9. Maws Expos(d6n&66/8pdg.;
Exterior Research and Design, LLC.
Certificate of Authorization #9503-
6 Nail Pattern
Esquema eon 6 daws
r r
IE- .� —;►I It— rr
5b/8" Fapasure Clails
ws 5 SW Exposure
rxpas(ddn de 6618prdg' ExposfcMn de 66/80idg.
Evaluation Report 037940.02.12-111
FL10674-117-
Date of Issuance: 02/06/2012
Revision 1: 08/22/2012
Page 4 of 6
6.2.9 Minimum Nailing — WeatherGuard@ HP:
:..
6.3 Hip lk Ridge Shingles:_
snit sift v4W
vaet;fes.r
r..r�xrl �,.
a..ttlbAhwZ,rf0=
�I TRINITY I ERD
6.3.1 Installation of Berkshire° Hip and Ridge Shingles, High Ridge, Hip & Ridge with Sealant and
WeatherGuard° HP Hip and Ridge Shingles shall comply with the manufacturer's current
published instructions, using four (4) nails per shingle. Refer to Owens Corning published
information on wind resistance and installation limitations, including the use of hand -sealing for
wind warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less
than FBC 1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing — Berkshire@ Hip & Ridge and High Ridge:
Fig.1 q
t— PreuallinDNMd
Direction A
Nails A
4
A I 1
A 1 I
I I I I
A I I I I
tY
F.%Postne
6.3.4 Minimum Nailing — Hip & Ridge with Sealant:
tern Fig. 2 - High W itd Fastening Pattern
(4 Nails]
rirn Shingle
and Discard
E6ccess
Sealant -•
Strip T 12
'Fastening, 55/s" 5"Exposure
Distance
12
Exterior Research and Design, LLC.
Certificate of Authorization #9503
Fig. 2
TopVlew Side%lew
Nails Nails
1. r Top Laminated 1
Piece
t- r
I
I
I
I
ml
.61
JI
ti EI
�I
I
I
I
I
Evaluation Report 037940.02.12-111
FL10674-R7
Date of Issuance: 02/06/2012
Revision 1: 08/22/2012
Page 5 of 6
I 1 ,
6.3.5 Minimum Nailing — WeatherGuard@ HP Hip and Ridge:
Fig. A 4 q
Prevailing wind
E— Uiredbn A
A
Nails q q
A I I
A I I
I I
I 1
A I I I I
�Exposu�
7. LABELING:
�I TRINITY I ERD
Fig. C Hip & Ridge Shingle Fastening
TopVlaw
1131b Nails
T'
2 2"
7° 1°
gEYposure
7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo
of the Accredited Quality Assurance Agency noted herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications
detailed in FBC Table 1507.2.7.1 / R905.2.6.1.
S. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the
installation of this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule
9N-3 QA requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC- QUA9625 ; (414) 248-6409; karen.buchmann�ul.com
Exterior Research and Design, LLC.
Certificate of Authorization #9503
END OF EVALUATION REPORT -
Evaluation Report 037940.02.12-111
FL10674-R7
Date of Issuance: 02/06/2012
Revision 1: 08/22/2012
Page 6 of 6
REVISIONS
Lu
Lil
BUILDING ROOF LAYOUT
SCALE: N.T.B.
jAr lkr A o 9) O O zp jAr
T
L
A
ROOF ZONES
SCALE: N.T.&
COMPONENT & CLADDING DESIGN PRESSURES:
ROOF
LOCATION
ACTUAL
ALLOWABLE
ZONE 1
FIELD
-24.4 PSF
-96.0 PSF (GABLE/HIP)
ZONE 2
PERIMETER
-51.5 PSF
-96.0 PSF (GABLE/HIP)
ZONE 3
CORNERS
-76.5 PSF
-96.0 PSF (GABLE/HIP)
WOOD DECKING:
GABLE/HIP: 15/32" (MIN.) PLYWOOD OR WOOD PLANKING @ 24" O.C. SPANS ATTACHED
WITH 8d RING SHANK NAILS OR #8 X 2" SCREWS @ 6" O.C. MAX. IN THE
FIELD & 6" O.C. MAX. AT THE PERIMETER.
CALCULATIONS BASED ON THE ROOFING APP. STANDARD (RAS117)
"OWENS CORNING" ASPHALT SHINGLE ATTACHMENT:
INSTALL WITH (4) NAILS MIN. IN ACCORDANCE WITH 2O10 FBC SECTION 1507.2 OR REFER
TO FLORIDA PRODUCT APPROVAL #FL10674-R7 FOR FURTHER INSTALLATION METHODS.
ROOFING CALC'S:
ZONE 1: (GABLEIHIP) ALL. UPLIFT = -96.0 PSF > ACT. = -24.4 PSF
ZONE 2: (GABLEIHIP) ALL. UPLIFT = -96.0 PSF > ACT. = -51.5 PSF
ZONE 3: (GABLEIHIP) ALL. UPLIFT = -96.0 PSF > ACT. = -76.6 PSF
NOTE:
SHINGLES ARE RATED TO 194 MPH (Vult) OR 150 MPH (Vasd) WHICH CORRELATES TO 96.0
PSF PER SECTION 1609 OF THE 2010 FBC.
NOTES:
1. ROOFING OVER EXISTING WOOD DECK.
2. INSTALL FASTENERS PER REQUIRED
FREQUENCY LISTED ABOVE FOR WOOD
DECKING & ROOF COVER.
3. FOLLOW ALL LOCAL & REGIONAL
ORDINANCES.
4. USE FASTENERS AS PER REQUIRED
MANUFACTURERS SPECIFICATIONS & FL#
10674-R7 FOR THE ASPHALT SHINGLES.
5. ALL DIMENSIONS ARE TO BE VERIFIED BY
CONTRACTOR.
z.
o
DESIGN CRITERIA: - 3j: w
2010 FBC ; Z - ' z
ASCE 7-10 Q
WIND LOAD: 160 MPH (Vultl
124 MPH c�%a�^ '••.
WIND BORNE DEBRIS REGff�N
MEAN ROOF HEIGHT: < 15.0' //,,III
GABLE/HIP
ENCLOSED BLDG.
BLDG CATEGORY II
EXPOSURE: "B"
ADJUSTMENT FACTOR: 1.00
GCPI: +/- 0.18
END ZONE (A): 4.8'
DRAWN
BY SASO'.
fllll�s
SCAI&
AS SHOWN
S-1