Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSr DATE: 11 1 1 1­k I FEES DUE: -1 S• t d I RECEIPT,#: It l 'Us ] I Permit M 130 ] _pp, ro Planning & Development Services Department m Building & Code Regulation Division ® 2300 Virginia Avenue Ft. Pierce, FL 34982-5652 �c�/'/ r= Tel. 772462-1553 APPLICATSEEIONEVERSEFOR �ROOF SPERMIT RUC/e CoU 1. Location/Site Address: `3s-� S �Pr�w,a VI t '% 131 v,t SDE FOR htY 2. Parcel ID Number: Office Use I Only Section I Township Range Map Page I Zoning Land Use Initials �s- v 3. Description of Project or Work Activity: r e 'co 0 f: 4. Total Roof Area (square feet): -z 4 4 5. Roof Pitch: WfQ 6. Type of Roof. [ ] Fiberglass Shingle [ ] Concrete Roof Tile [ ] Wood Shake / Shingle [ ] Tar & Gravel [ ] Modified Bitumen Pq Other S v cnMQ PM Product Approval required for all types of Roofing Material (2 Sets) VJ All.Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product Approval attached ** Roof Mitigation per F.S. 553.844 will be required. 7. Owner Information 8. Contractor Information Name: Alex A, Love-?-- FL Reg/Cert #: e c C 15 3o I o c( Address: 3,s f- Se Fri mg, v is tz, 'Dl v L County Cert #: City: Qo r+ s t . 1 ac, a State: 1^ C Business Name: To-w vC3,19 s!s+c�" s 5fcc,c i , sk Zip: 3119 6,3 Phone: 312 Cell Phone: -q3a,_ qa3- 3110 9. Value of Construction: $ l o, oe o "Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval. CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in compliance with all applicable laws regulating construction and zoning. '2�car�b (ara 12c2,,A PRINT QUALIFIERS/OWNERS NAME SIGNATURE OF QUALIFIER/OWNER STATE OF FLORIDA, COUNTY OF ACKNOWLEDGED BEFORE ME THIS DAY OF 3°6 20�, BY A: a►i gr- WHO. IS PERSONALLY KNOWN TO ME OR HAS PRODUCED TP L O L LGA a'1FIC� GIVENS ,1 .•`is`r aye :'a Notary public,; Stata of Florida SIGNATURE OF• NOTARY TYPE OR PRINT' NAME OF NOTARY • i My Comm. Expires t)eL 2016Commission N EE 61COMMISSION NUMBER �'. $ �4,0 1Bonded ThroughNIWIll Assn: NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Revised 4/26/2010 INSTRUCTIONS Please complete all information in the space provided. All information must be printed (use black or blue ink only) or typed. ,This roof permit application is to be used only for those activities that are not otherwise included under a primary building permit. This application may not be used for any activity that includes structural alteration. Building activities involving structural alteration, in addition to the roof work, must be permitted through the regular building permit review process. The information to be provided with this application includes: 1. Location/Site Address 2. Parcel ID Number 3. Description of Project or Work Activity 4. Total Roof Area 5. Type of Roof 6. Owner Information 7. Contractor Information 8. Value of Construction Indicate the street address or general location of the property where the building activity is taking place. Indicate the tax identification number of the property where the building activity is taking place. Completely describe the building activity to take place. Please indicate if tear -off or shingle over shingle etc. Indicate total roof area to be affected by this permit. Also indicate the pitch of the roof, expressed as a standard ratio of run rise. Indicate the type of roof being repaired or resurfaced. Indicate the name and address of the owner of the property on which building activity is taking place. Indicate the State of Florida registration number (if applicable), St. Lucie County contractor license number and the name of the business doing the work. Indicate the total value of the work to take place. Total cost of construction includes all material and labor costs associated with the building/construction activity. Construction value is used to determine the permit fee. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction. This application can be submitted to St. Lucie County Building and Zoning, 2300 Virginia Avenue, Fort Pierce, FL aims t e filled out completely before submission. No applications will be ac l}p }oiQvn' 6 nj after.4: 0 . For assistance in completing this application, please call (772) 46 df3 rduatdg41�4F,o1iv.11 ( 00 AM - 5:00 PM), Monday through Friday. *Tueo 33 0 noiaaicnrno'J U St. Lucie County Roof Permit Application rev. 3/1/2009 can be scheduled by calling (772)' 462-1261. 'F•' Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 772-462-2165 or 772-462-2172 Fax: 772-462-6443 ROOF INSPECTION AFFIDAVIT Re: Permit # IfJ I ~0 7/ I,jY1�S 1401'rt'Y7CZ.i� , licensed as a(n)Contractor*/Engineer/Architect (Please print name & circle license type) *FS468 Building inspector *General, Building, Residential or Roofing Contractor or any Individual certftled under 469 F.$ to make such an Inspection. On or about. ! f�o�i . I did personally .inspectthe roof deck na'linx (Date) work at: -790%:r_ (Job site address) Based up\nthat examination I have determined the Installatlon was done according to the current edition oFlorida Existing Building Code Section 611 or the product approval submitted (whichever Is most stri Signature*d Seal STATE OF FLORI0 COUNTY OF license # S ro r�,to and sulgsq jpd before me this 16 day of 20,9 bvy.A 1_0dJ &. Who is personally ky(96n to me oKjNho has produced as identification. Notary Public, State of F a Signature of Notary: Commission Number: En01/19/2011 RECEIVED JAN 16 2013 p 'R"CAMMISsION>tDD859309 2013 rr� OFF wwyy,p,A,RONNO ARY.a1m wi TOO18 XX3 pf: 9T CTOZ/9T/TO planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Fierce, FL 34982 M-462-2165 or 772-462-2172 Fax: 772-46Z-6443 ROOF INSPECTION AFFIDAVIT Re: Permit 3O . - 00 -:t4 licensed as a(n)Contractor*/Engineer/Architect 1, *FS468 Building Inspector (Please print name & circle license type) *&er►erol, Building, Residen.Vol or Roofing Contractor or any individual certified under 468 F.S. to make such on inspection. on or about l _ I - Imo-, I did personally inspect the roof deck Wallin (Date) work at: 5 p (Job site address) Based upon that examination I have determined the installation was done according to the current edition of the Florida Existing Building Code Section 611 or the product approval submitted (whichever is most strigent). Signature and Seal C:C� 13301 C7 License # STATE OF FLORIDA COUNTY OF sworn to andsubscribed before me this IA—_ day of 2013, by who is personaily known to me ar who has produced as identification. Notary Public, State of lFlo_riida � e Signature of Notary; (Seal) Commission Number: �n 01/19/2011 R R: JAN 16 2013 ,� :"%.":;4f+ YICinRIA DIAN!!f: h(CKt�1 * * MY COMMIt3S14N r EE 2140 EXPIRES; July 21, 2016 `���}��' ea�ar�ueuc�elltaHysbwr�e JOSEPH E . SMZT1, _ ,:LERK OF THE CIRCUVE COURT - S �cT LVC7E COUNT-r FILE # 3790970 "OR BOOK 3474 PAGE 2830, Recorded 01/16/2013 aLt 10:52 1301 OD7(o F"ermit No. State of Florida county of%Lucle OTI OF [�MMF�EIJ+ECJT Tax Folio No. The undersigned her'ehyyares rrOtleptllat Iroproverl[e0t' wit[ pv "nude to cerrorn +ual Propvlty, and in 410e0rdunce with [:hatter 71a, Florida Statute~, thef011ow1ng IOfarmadOn is Provided in ibis Notice of CammaneemepL of PrsOperty: Land:l-or address!f available); 13enrrri deseriptlop 011mpnOYrrnon, bwnar blf ennolen or tour■ bst n,.Uan if tM L=M contraetsd for the bit Name AI ptovement: Address lilterast in Property; — Name arid +Idd[e a oftee simpler daholder(If dlHOretttfroth olvner I[stetl abavoi; tdntrrctoes Noma ',a.I�l +t —Awl»" S c �^ CanrrettorAddress:"� • phaneNrarrber.SumtY ,�. lfrpp6cablq acopy oYthe payntrnibondrsartacbod�AmuuMofbondr$ ~ Nlimcabmeond address: LenderNo „_PllanenUmher• .0 j¢' mr! A Lendery address: PltunO Nurrtbar: PAt U wlr}rhr dr0 SLte of tt",di dnsrpsltztgt f�Y owner On wlrgtn rwtlees nr arise" ch"AlIft r t he srrvedq N1i�1 h)7ti Flerlda swsuur; "P rY Y tOCttan Prevldod b Addrts: Phone Number: r N addition to niryn elf or hemulf, pvrner daslgnat% Lienor s Nedty a& provided In; Secilpn,7,yLWI 1) (pl FItNIW, Statutes. ^' 10 receive a Copy of the Phone numbor of person or entity CeSi4nated by owner . Expfrlitioli Mur, ateof,mpCeufcommrncetnont:(the expfrauandate may not Wbefore the roo, Conlragar, but will Ile 1 year from the date. of remrdb a rUnfess a dfrfe,rn[dat0 is spe[If[ed) Plet+pn Of consVucklOn and lion a I p yme,re to the WARNING TO OWNER' ANY PAYMENTS MADE BY THE OWNER AFYERTHE EXPIRATION OP TkE N"Cr OF COMMENCEMENTAkF: CONSIDERED IMPROPER PNrj'5 TO V UNDFJt CfrAPTER 713, PART I, SECTION ]1113, FLORIDA STATUT✓:S, AND GAM RESULT, IN YOUR PAYING TWICE FOR IMWtOVEMENI S TO YOUR PROPERTY, A 14011CL" OF OOMMENSENreNTMST RM RECORDED AND REMADIICN. OUR r4INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENOM OR AN ATTORNEY BEFORE COMiU✓FNONG FOVZORX OR RECOApIN6 YOUR NOTICE OF CgMMGyCE LENT. �' F tj RE THE Jo$ yTN W RE OR Pfksi UnderOf rlurV,ldard rthaii rnY IM hell hat* read theforLWI notice of 0otnmcncemantandtkattheraCtsstttedthen:inare' true tou � +e best Ur (s1811tlrara of CS her Or Lessee, or Hers or tAPsee ,e (578nat0ty's —Ti tle/otllm) TI,afOreyoinginstrumnntwasacknowledgedbe{of methis ))b aL_ `daynf , 20% NalnaO sot to O?" . O 1 y rope of auehorty{pis• omeer, trustee) PurtM behalf of whogr in "tun executed rot wac e,rccu[ed (Slgnalvro Noiery u - Slate of Fturtda} Personally knovr [print, T urStan,p m$GrOn.0 Name 0f N0taryPULlic) k. Crproducep;dentlficatr0u.� Type of UsOndBcarion produced 4 4a IFrS fA Vti j�rNAMY � NowrYFdall,„5fa�lordFlGkia t1V =%k ifi, 2,,114 etlf r LUCIE IN% �00&,TY ��6I�fS r,�rFkl'IFY7rt1� r u A r'' lii��DFCy 1lSiSA BAN 16 2013 OR( ,ll.. aPJDF THE 1 _J Florida Building Code Online f -_ Page 1 of 2 i t , Florida Depaltmentof BCIS Home Login User Registration Hot Topics Submit Surcharge Busines� Professional roll 'd PrBo�duct Approval : Public User Regulation A-16 � tt Stats & Facts Publications FBC Staff BCIS Site Map Links Search i Product Aooroval Menu > Product or Application Search > Application List > Application Detail FL # FL1251Q$2 Mtn- (J Application Type Revislor . Cd ,i7 y BBUtnDNG DWISI Code Version 2010 RU'E WED F Application Status Approve4�%� - 7Y Comments DATA 4,79 Archived i PLAN9 AND PERMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE. Product Manufacturer PrimeSource Building Products, Inc. Address/Phone/Email 2115 East Beltline Road Carrollton, TX 75006 (508)436-6100 barregop@primesourcebp.com Authorized Signature Pete Barrego barregop@primesourcebp.com Technical Representative Pete Barrego Address/Phone/Email 333 Manley Street West Bridgewater, MA 02379 (508)436-6100 barregop@primesourcebp.com Quality Assurance Representative Address/Phone/Email Category Roofing FILE C0106Y Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who Robert Nieminen developed the Evaluation Report Florida License PE-59166 Quality Assurance Entity Underwriters Laboratories Inc. Quality Assurance Contract Expiration Date 09/03/2013 Validated By John W. Knezevich, PE Cal Validation Checklist - Hardcopy Received Certificate of Independence FL12510 R2 COI Trinity ERD CI - Nieminen.odf Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code l 1507.2.3 1507.3.3 http://www.floridabuilding.org/pr/pr_app_dtl. aspx?param=wGEVXQwtDgvG4Aty8UaH... 10/25/2012 Florida Building Code Online r-� Page 2 of 2 1507.5.3 1507.7.3 1507.8.3 1507.9.3 1507.9.5 R905.2.3 R905.2.7 R905.4.3 R905.6.3 Product Approval Method Method 2 Option B Date Submitted 12/15/2011 Date Validated 01/20/2012 Date Pending FBC Approval 02/01/2012 Date Approved 04/03/2012 Summary of Products FL # Model, Number or Description Name 12510.1 Grip -Rite Synthetic roof underlayment Shinglelayment— Synthetic Roofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ: No FL12510 R2 II er011812FINAL PRIMESOURCE Underlavments FL12510- R2.Ddf Approved for use outside HVHZ: Yes Verified By: Robert Nieminen PE-59166 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: 1.) Refer to ER Section 5 for FL12510 R2 AE er011812FINAL PRIMESOURCE Underlavments FL12510- R2.odf Limits of Use. 2.) While the dimensions and masses set forth in Created by Independent Third Party: Yes ASTM D226 and D4869 are not applicable to this product, the product exceeds the performance requirements of these specifications. 3.) ASTM D6757 is not an applicable standard to certify this product, as it Is not a felt or fiber -reinforced. Back Next Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. •Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: ® eCh_ CrediVrarFdE http://www.floridabuilding. org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvG4Aty8UaH... 10/25/2012 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 I 353 CHRISTIAN STREET, UNIT #13 QOTRINITYIERD OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 EVALUATION REPORT PrimeSource Building Products, Inc. Evaluation Report P40180.01.12 2115 East Beltline Road FL12510-112 Carrollton, TX 75006 Date of Issuance: 01/18/2012 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2010 Florida Building Code sections noted herein. DESCRIPTION: PrimeSource Roof Underlayments LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 4. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 01/18/2012 This does not serve as an electronically signed document. Signed, sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. TrinitylERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. I rTRINITY ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: PrimeSource Roof Underlayments, as produced by PrimeSource Building Products, Inc., have demonstrated compliance with the intent of following sections of the Florida Building Code through testing in accordance with applicable sections of the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section 1507.2.3, 1507.3.3, 1507.5.3, 1507.7.3, T1507.8, 1507.8.3, 1507.9.3, 1507.9.5 1507.2.3, 1507.5.3, 1507.7.3, 1507.8.3, 1507.9.3 1507.3.3 3. REFERENCES: Entity ERD (TST6049) ERD (TST6049) Miami -Dade (CER1592) ICC-ES (EVL2396) UL (QUA1743) 4. PRODUCT DESCRIPTION: Properties Standard Year Unrolling, Breaking Strength, ASTM D226 2006 Pliability; Loss on Heating Unrolling, Tear Strength, ASTM D4869 2005 Pliability, Loss on Heating, Liquid Water Transmission, Breaking Strength, Dimensional Stability Installation Practice FRSA/TRI 07320 2005 Examination Reference Date Physical Properties P12460.03.09 03/19/2009 Physical Properties P12460.04.09-R2 03/02/2011 FBC HVHZ compliance 10-0921.11 12/30/2010 IBC compliance ESR-2945 03/01/2011 Quality Control Service Confirm, R26348 Exp. 09/03/2013 4.1 Grip -Rite ShinglelaymentTM Synthetic Roofing Underlayment is a woven polypropylene, coated roof underlayment. S. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVHZ. 5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory or test report from accredited testing agency for fire ratings of this product. 5.3 PrimeSource Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the AHJ for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.4 Allowable roof covers applied atop PrimeSource Roof Underlayments are follows: Table 1: Roof Cover Options Underlayment Asphalt Nail -On Tile Foam -On Metal Wood Shakes & Slate or Simulated Shingles Tile Shingles Slate Grip -Rite Shinglelayment'" Yes Synthetic Roofing Yes No Yes Yes Yes Underlayment (See Section 5.6) Exterior Research and Design, LLC. Evaluation Report P40180.01.12 Certificate of Authorization #9503 FL12510-R2 Date of Issuance: 01/18/2012 Page 2 of 4 rTRINITYIERD 5.5 Exposure Limitations: 5.5.1 Grip -Rite ShinglelaymentTM Synthetic Roofing Underlayment shall not be left exposed for longer than 30-days after installation. 5.6 For tile roof installations governed by the FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, use is limited to the.following. Table 2: Tile System Options per FRSA/TRI 07320/8-05 System Option Section Reference Roof Underlayment(s) System One: Mechanically Fastened Tile, 4 3.02D Double -layer, Double -layer, Grip -Rite Shinglelayment— Synthetic Unsealed or Sealed Underlayment No. 30 Roofing Underlayment System 6. INSTALLATION: 6.1 PrimeSource Roof Underlayments shall be installed in accordance with PrimeSource Building Products, Inc. published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Grip -Rite Shinglelavmentym Synthetic Roofing Underlayment: 6.2.1 Install Grip -Rite ShinglelaymentTM Synthetic Roofing Underlayment in compliance with manufacturer's published installation instructions and the requirements for ASTM D226 or D4869 underlayments in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.2.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application. 6.2.3 Corrosion resistant fasteners shall be plastic cap nails with minimum 1-inch diameter head. Ensure fasteners are installed at 90 degree angle to the deck with flush contact between the plastic cap and the upper surface of the underlayment. Fasteners shall be of sufficient length to penetrate through the underside of plywood or OSB decks, or minimum 3/4-inch embedment into dimensional lumber / tongue -and -grove wood decks. 6.2.4 Install a leak barrier of ASTM D1970 or equal holding Florida Statewide Product Approval at vulnerable leak areas, including but not limited to eaves, valleys, rakes, skylights and dormers. At eaves and valleys, install the leak barrier prior to installation of Grip -Rite ShinglelaymentTM. Along the rake, install Grip -Rite ShinglelaymentT'", leaving 6 to 8-inch of the deck exposed, and then install the leak barrier over the Grip -Rite ShinglelaymentT" and exposed decking. At other areas, install the leak barrier over the Grip -Rite ShinglelaymentT"' 6.2.5 For non -tile roof installations: 6.2.5.1 Single Layer; Roof Slope > 4:12: Starting at the eave, fasten the eave edge and 6-inch vertical laps max. 8-inch o.c., and max. 24-inch o.c. down the center of the roll. Continue upslope in a similar manner, maintaining minimum 4-inch horizontal and minimum 6-inch vertical laps. Fasten 8-inch o.c. at the laps and 24-inch o.c. down the center of the roll. Ensure all vertical laps are staggered at least 3-feet apart. In wind zones of V„lt > 142 mph per FBC Figure 1609A, 1609E or 1609C (Vasd > 110 mph per FBC 1609.3.1), increase the fastening schedule to 4-inch o.c. at all laps and 24-inch o.c. down the center of the sheet in the field of the roof. 6.2.5.2 Double Layer; 2:12 < Roof Slope < 4:12: Starting at the eave, fasten the eave-edge of a half -width starter -strip and 6-inch wide vertical laps 8-inch o.c. Exterior Research and Design, LLC. Evaluation Report P40180.01.12 Certificate of Authorization #9503 FL12510-112 Date of Issuance: 01/18/2012 Page 3 of 4 ��TRINITYJ ERD Continue upslope in a similar manner, with minimum 24-inch horizontal and minimum 6-inch vertical laps. Fasten 8-inch o.c. along the low edge and vertical laps and 24-inch o.c. down the center of the roll. Ensure all vertical laps are staggered at least 3-feet apart. In wind zones of V„it > 142 mph per FBC Figure 1609A, 1609B or 1609C (Vasd > 110 mph per FBC 1609.3.1), increase the fastening schedule to 4-inch o.c. at all laps and 24-inch o.c. down the center of the sheet in the field of the roof. 6.2.6 For tile roof installation: 6.2.6.1 Installation is governed by the FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition. Use is limited to System 1, Option 4, Section 3.02D in place of the "No. 30" felt; min. 4:12 slope, under battens. In this case, the "starter strip" and "full -width -sheet" referenced therein shall be proportionate to the width of the Grip -Rite ShinglelaymentTM product. A half -width starter strip shall be applied horizontally at the eaves. A full -width sheet shall be applied covering the starter sheet. 6.2.6.2 PrimeSource recommends use of a pressure sensitive, double sided tape or an SBS peel and stick foil -faced or double sided tape as a gasket between the batten and the underlayment. 6.2.6.3 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. PrimeSource defers to the tile manufacturer on use of tiles directly over its Grip -Rite ShinglelaymentTM Synthetic Roofing Underlayment. 6.2.7 For batten -secured roof covers: 6.2.7.1 When battens are installed over Grip-RiteT14 Synthetic Underlayment, the underlayment need only be preliminarily attached in advance of batten installation. Ensure preliminary underlayment attachment does not interfere with batten locations. 6.2.7.2 PrimeSource recommends use of a pressure sensitive, double sided tape or an SBS peel and stick foil -faced or double sided tape as a gasket between the batten and the underlayment. 6.2.8 Grip -Rite ShinglelaymentT'" Synthetic Roofing Underlayment may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details. 7. LABELING: Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. S. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the manufacturer or the named QA entity for information on plants covered under Rule 9N-3 QA requirements. 10 QUALITY ASSURANCE ENTITY: Underwriters Laboratories — QUA1743; (314) 578-3406, k.chancellor@us.ul.com - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report P40180.01.12 Certificate of Authorization #9503 FL12510-R2 Date of Issuance: 01/18/2012 Page 4 of 4 SpPclalty Structural Engllnpertng Evaluation Report "5V Crimp" Metal Roof Assembly Manufacturer: Sunlast Metal, Inc. 2120 SW Poma Drive Palm City, FL 34990 (772) 223-4055 for Florida Product Approval # FL 10490.6 R3 CBUCK, Inc. Certificate of Authorization #8064 Florida Building Code 2010 Per Rule 9N-3 Method: 1- D Category: Roofing Sub - Category: Metal Roofing Product: "5V Crimp" Roof Panel Material: Steel Panel Thickness: 26 gauge Panel Width: 24" Support: Wood Deck Prepared by: James L. Buckner, P.E., S.E.C.B. Florida Professional Engineer # 31242 Florida Evaluation ANE ID: 1916 Project Manager: Diana Galloway Report No. 12-139-5V-S6W-ER Date: 4 / 16 / 12 Contents: Evaluation Report Pages 1— 7 CBUCK, Inc. 1399 N. Killian Drive, Suite 4, West Palm Beach, Florida 33403 Phone: (561)491-9927 Fax: (561)491-9928 Website: www.cbuckinc.net -1411 . . ................ A a es L. Buckner, P.E., SECB Florida E. # 1242 G 1'I iZ FL #: FL 10490.E-113 �Date: 4 / 6 / 12 CBUCK Engineering Page rt No.: 22of 7 5V-S6W-ER Specialty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064 Manufacturer: Product Name: Product Category: Sunlast Metal, Inc. "5V Crimp" Roofing Product Sub -Category Metal Roofing Compliance Method: State Product Approval Rule 9N-3.005 (1) (d) Product/System "5V Crimp" Description: 26 gauge Steel roof panel mechanically attached to Plywood Deck with screws. Product Assembly as Refer to Page 4 of this report for product assembly components/materials & Evaluated: standards: 1. Roof Panel 2. Fasteners 3. Underlayment Support: Type: Wood Deck (Design of support and its attachment to support framing is outside the scope of this evaluation.) Description: • 15/32 (min.) or greater plywood, • or Wood plank (min. specific gravity of 0.42) Slope: Minimum slope shall be in accordance with manufacturer's recommendations, FBC Section 1507.4.2 and applicable code sections. Performance: Wind Uplift Resistance: • Design Uplift Pressure: METHOD 1 - 50.5 PSF (Refer to "Table A" attachment details herein) M H FL #: FL 10490.6-113 Date: 4 / 6 / 12 Report No.: 12-139-5V-S6W-ER Page 3 of 7 Specialty Structural Englineerinq CBUCK, Inc. Certificate of Authorization #8064 Performance Standards: The product described herein has demonstrated compliance with: • U L580-06 — Test for Uplift Resistance of Roof Assemblies • U L 1897-04 — Uplift test for roof covering systems • TAS 125-03 —Standard Requirements for Metal Roofing Systems Standards Equivalency: The UL 580-94 & UL 1897-98 standard version used to test the evaluated product assembly is equivalent with the prescribed standards in UL 580-06 & UL 1897-04 adopted by the Florida Building Code 2010. Code Compliance: The product described herein has demonstrated compliance with Florida Building Code 2010, Section 1504.3.2. Evaluation Report This product evaluation is limited to compliance with the structural requirements Scope: of the Florida Building Code, as related to the scope section to Florida Product Approval Rule 9N-3.001. Limitations and • Scope of "Limitations and Conditions of Use" for this evaluation: Conditions of Use: This evaluation report for "Optional Statewide Approval' contains technical documentation, specifications and installation method(s) which include "Limitations and Conditions of Use" throughout the report in accordance with Rule 9N-3.005. Per Rule 9N-3.004, the Florida Building Commission is the authority to approve products under "Optional Statewide Approval'. • Option for application outside "Limitations and Conditions of Use" Rule 9N-3.005(1)(e) allows engineering analysis for "project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code". Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. • Design of support system is outside the scope of this report. • Fire Classification is outside the scope of Rule 9N-3, and is therefore not included in this evaluation. • This evaluation report does not evaluate the use of this product for use in the High Velocity Hurricane Zone code section. (Dade & Broward Counties) Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in accordance with the Florida Building Code and Rule 9N-3.0005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity through Keystone Certifications, Inc. (FBC Organization #: QUA 1824). �r FL #: FL 10490.6-113 Date: 4 / 6 / 12 \ CEBUCK.Engineerin Page Report No.: 4 of 7-5V-56W-ER Speclaltly Structural r=nglrleering CBUCK, Inc. Certificate of Authorization #8064 Components/Materials (by Manufacturer): Roof Panel: Material: Thickness: Panel Width: Rib Height: Yield Strength: Corrosion Resistance: Fastener: Type: Size : Corrosion Resistance: Standard: "5V Crimp" Steel 26 gauge (min.) 24" (max.) Coverage 1/2„ 40 ksi min. In compliance with FBC Section 1507.4.3: • ASTM A792 coated, or • ASTM A653 G90 galvanized steel Hex -Head Wood Screw with WSW #10 x 1-1/2" " Per FBC Section 1506.6 and 1507.4.4 Per ANSI/ASME B18.6.4 Underlayment: Per roofing manufacturer's guidelines in compliance with FBC Section 1507.4.5 Insulation (Optional): Type: Thickness: Properties: Density: Or Compressive Strength Rigid Insulation Board 3" (max.) 2.25 pcf (Ibs/ft3) min. 20 psi min. Insulation shall comply with FBC Section 1508. When insulation is incorporated, fastener length shall conform to penetrate thru bottom of support a minimum of 3/16". FL #: FL 10490.6-113 Date: 4 / 6 / 12 Report No.: 12-139-5V-S6W-ER Page 5 of 7 ISpeclaltly Structural Engineering CBUCK, Inc. Certificate of Authorization #8064 Installation: Installation Method: (Refer to drawings on Pages 6-7 of this report.) ■ Row spacing: Refer to Table "A" (along the length of the panel) ■ Fastener spacing: Nominal pattern of 12" ox. (along the row, across the panel profile & at the top of corrugation peaks) ■ Rib Interlock: Lapped ■ Minimum fastener penetration thru bottom of support, 3/16". ■ For panel construction at the end of panels, refer to manufacturer's instructions and any site specific design. TABLE "A" METHOD 1: METHOD 2: Design Pressure: - 50.5 PSF106675 PSF� �m Row Spacing: 16" Fastener Spacing: 12" a12y�� y Install the "5V Crimp" roof panel assembly in compliance with the installation method listed in this report and applicable code sections of FBC 2010. The installation method described herein is in accordance with the scope of this evaluation report. Refer to manufacturer's installation instructions as a supplemental guide for attachment. Referenced Data: 1. TAS 125-03 Uplift Test Hurricane Test Laboratory, LLC (FBC Organization #TST ID: 1527) Report #: 0412-1017-05, Report Date: 02/22/06 2. Quality Assurance By Keystone Certifications, Inc. (QUA ID: 1824) Sunlast Metal & Solar, Inc. Licensee # 385 3. Engineering Analysis By CBUCK Engineering 4. Equivalency of Test Standard Certification By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization # ANE 1916) 5. Certification of Independence By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization # ANE 1916) FL #: FL 10490.6-113 Date: 4 / 6 / 12 U ro�nl rin Report No.: 12-139-5V-S6W-ER Page 6 of 7 Speclalty Structural Englneprinq CBUCK, Inc. Certificate of Authorization #8064 Installation Method Sunlast Metal, Inc. "5V Crimp" (26 Gauge) Roof Panel Attached to Wood Deck Profile Drawings 24" Maximum Net Coverage c N T "5V Crimp" Panel Typical Panel Profile View Nominal 12" o.c. I Nominal 12" o.c. Fastener Spacing Across Panel Width #10 Hex -Head Screw with WSW Spaced 12" across the Panel Assembly Profile View Typical Fastening Pattern Across Row r ` FL #: FL 10490.6-113 Date: 4 / 6 / 12 CBUCK EngineeringReport No.: 12-139-5V-56W-ER Page 7 of 7 Speclalty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064 Installation Method Sunlast Metal, Inc. "5V Crimp" (24 Gauge) Roof Panel Attached to Wood Deck Panel Fasteners - #10 Hex Head 15/32' or greater Plywood, or Insulation 3" maximum - Wood plank Typical Assembly Isometric View TABLE "A" METHOD 1: METHOD 2: Design Pressure: - 50.5 PSF -106.75 PSF Row Spacing: 16" 8" Fastener Spacing: 12" 12"