HomeMy WebLinkAboutSUBMITTED PAPERSNJUSrIi`'.� i�/��'.r��I[IIIQTT1Jy�
Planning & Development Services
Building & Code Regulations Division
2300 Virginia Ave.
Fort Pierce, FL 34982
(772)462-1553
SCByIVSD
of Lucie County
SPECIALTY PERMIT APPLICATION
B Electrical ❑ Plumbing ❑ HVAC ❑ Fence
❑ Shed ❑ Demolition ❑ Gas ❑ Siding
See page 2 for instructions and additional paperwork required for specialty perinits
1. Location/Site Address: 10150 PERFECT DR
2. Parcel ID Number: 3327-200-0001-000-4
Office Use
Only
Section
Township
Range
Map Page
Zoning
Land Use
Initials
-:R
)
33 L3,0
' 1
3. Complete Description of Project or Work:
4. Owners Information 5. Contractors Information
Name: PGA Reserve Inc FL Reg/Cert #:
Address: 951 SW Country Club Dr County Cert#:
City. Port St Lucie State: FL Business Name:
Lcoo IC
'z6930
Zip: 34986 Phone: Phone: Cl,-zt- 9 S'q Fax:
6. Value of Construction: $
1500
re-- M e— Vl c-
OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in
compliance with all applicable laws regulating con trucon and zonia�
�� e-7
i� PRINT_0-W-,NER OR CONTR-AGTORNA'ME,n SIGN / OFfO 71O ACT
STATE OF FLORIDA, COUNTY OF � bQ T
�
ACKNOWLEDGED BEFORE ME THI$ DAY OF 20AA--_, BY Q.�EX
WHO
WHO IS PERSONALLY KNOWN TOME ✓ OR WHO HAS PRODUCED J rr
AS IDENTIFICATION.
SIGNATURE OF NOTARY TYPE OR PRINT NAME OF NOTARY %'7�F
COMMISSION NUMBER
Nfflll111\
NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR
LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
EXEMPT: A/C -HEAT REPLACEMENT WITH CONTRACT UNDER $7500.00
Revised 04/26/2010
Meshenberg, Milana
From:
Irvie Saunders [saundersi@stlucieco.org]
Sent:
Wednesday, February 02, 2011 10:16 AM
To:
Meshenberg, Milana
Cc:
Paula Bushby; Robin Meyer; Kenneth Arnold
Subject:
RE: PGA of Americas In -Building for St. Lucie
--Sensitivity:
Confidential'
Thank you for sending the information clarifyingyouur_project. Upon rev_ieV with the Building Official it has been
deter-mined-that-the-inst�Ilation=af-the=tr=i=sector--monap>ale-will req.uire_a=pecmit-fram. S_t=Lucie Cou_ nty_.._ We.would_
however require an electrical permit if installation requires running e lectrica I*. wi H ng to the monopole. If you have any
questions regarding the electric, you can contact our._Building Official,-at.772-462-1553.
0
Irvie Saunders —
Aann ng tech.
Planning andDeveCo_PlMent Services
Office: (772)462-1557
Email saundersi@stCuc eco.OrA
Frdm: Meshenberg, Milana [mailto:Milana.Meshenbergi@T-Mobile.com]
Sent: Tuesday, February 01, 2011 6:38 PMI
To: Irvie Saunders
Subject: PGA of Americas In -Building for St. Lucie
Sensitivity: Confidential
Hi,
Please find attached a picture, with specs, regarding the antenna we are proposing to install inside the clock tower.
Please let me know if you need additional information. As I mentioned when we spoke, the placement of the antenna
will be stealth so it will not be visible..
Thank you and have a great day,
Milana Meshenberg
Site Acquisition/Zoning Specialist II,
Multipoint Wireless LLC
on behalf of T-Mobile South LLC
1300 Concord Terrace
Suite 200
Sunrise, FL 33323
Tel: 786.859.9080
Fax: 954.241.6773
Email: Milana.Meshenbergl@T-Mobile.com
Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records
available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and /
or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error,
please notify the sender by reply e-mail and delete all materials from all computers.
e
r
PGA ST. LUCIE PORT ST. LUCIE
A11014B
1 UICILUM
CALTROP Project Number 11-441.37
STRUCTURAL CALCULATIONS
For
New Rooftop Antenna Masts
PGA St. Lucie Port St. Lucie (AH014A)
1916 Perfect Drive
Port Saint Lucie, Saint Lucie County, FL 34986
April 7, 2011
Prepared by: Michael A. Phillips, P.E.
Senior Engineer
Florida Registration, 68312
1EAMLTRUP,
Job Summary:
T-Mobile requested that we perform a structural design of proposed rooftop antenna masts to be located at
1916 Perfect Drive in Port Saint Lucie, Saint Lucie County, Florida. It is our understanding that T-
Mobile wishes to install a new telecommunications antennas on the proposed masts, as depicted in the
construction drawings we have prepared.
We based our design on information obtained during our site visits, published catalog information, and
documentation provided by our client. Our analysis was performed in accordance with the Florida
Building Code, 2007 Edition with 2009 Amendments, with the design criteria listed below. We utilized
hand calculation in accordance with the American Institute of Steel Construction Steel Construction
Manual, to verify that the proposed masts could adequately sustain the loads applied to them by the
proposed antennas. Based on our analysis, the proposed masts can adequately support the proposed
equipment antennas. Refer to the attached drawings for additional information.
Design Criteria:
V = 130mph (3-second gust)
Exp. C
I = 1.0
GCpi = 0.00
Codes:
Building: 2007 Florida Building Code'with 2009 Amendments
Loads: ASCE 7-05
Steel: AISC LRFD 131h Edition
Concrete: ACI 318-05
Wind Load - Antennas:
In Accordance With ASCE 7-05
Design Criteria
Wind Velocity, V = 130 mph
Exposure = C
Building Category = II
(ASCE Table 1-1)
Equipment
H =
1.91 ft
(Equipment Height Dimension)
W =
0.83 ft
(Equipment Width Dimension)
D =
0.83 ft
(Equipment Depth Dimension)
Round ?
Y
(Equipment is Round or Not)
Z =
30 ft
(Equipment Height Above Ground)
Design Parameters
JOB NO. 11-441.37 SHEET 1 OF 1
JOB NAME PGA St Lucie Port St Lucie
BY M. Phillips DATE 7 APR 2011
CHECKED BY JJ DATE 7 APR 2011
CALTROP Corporation 3400 Lakeside Drive, Suite 525, Miramar, FL 33027
CeIIMax CMA-TRI/6515/E2
Zg = 900
(ASCE Table 6-2) Zmin = 15. (ASCE Table 6-2)
a. = 9.5
(ASCE Table 6-2) E = 0.2 (ASCE Table 6-2)
e = 500
(ASCE Table 6-2) ZBAR = 18 (ASCE 6.5.8.1)
c = 0.2
(ASCE Table 6-2)
=
1.00
(Importance Factor, I from ASCE Table 6-1)
G =
0.92
(Gust Factor, ASCE EQ. 6-4)
KZ =
0.98
(Coefficient from ASCE Table 6-3)
Kn =
1.0
(Topographic Factor from ASCE Figure 6-4)
Kd =
0.85
(Directionality Factor from ASCE Table 6-4)
Velocity Pressure
qZ = 0.00256(V2)(1)(Kj(Krt)(Kd) (ASCE EQ, 6-15)
qZ = 36.1 psf
Wind Load
Case 1: Wind at Front
H/D = 2.29
Cf = 0.7
Af = 1.59
FFRONT — 72 IbS
(ASCE Figure 6-2 1)
(Total Lateral Force, ASCE Eq. 6-28)
Z = 18 (Effective Height) Q = 0.99 (ASCE EQ. 6-6)
I-z = 443 (ASCE EQ. 6-7) T = 1.9 (ASCE 6.5.15.1)
Iz = 0.22 (ASCE EQ. 6-5)
ii
l i€
1 1�
,I
I
1
— f
Case 1: Wind at Front
ANTENNA
TOP
p = 23.9 psf
Case 2: Wind at Side
N
a oANTENNA
ii TOP
o.
Antenna Weight = 26.0 Ibs
0■
- - ME
AM k
C 0% M.
Wind Load - Pipe
In Accordance With ASCE 7-05
Design Criteria
Wind Velocity, V = 130 mph
Exposure = C
Building Category = II
(ASCE Table 1-1)
Equipment
H = 6 ft (Equipment Height Dimension)
W = 0.24 ft (Equipment Width Dimension)
D = 0.24 ft (Equipment Depth Dimension)
Round ? Y (Equipment is Round or Not)
z = 30 ft (Equipment Height Above Ground)
Design.Parameters
JOB NO. 11-441.37 SHEET 1 OF 1
JOB NAME PGA St Lucie Port St Lucie
BY M. Phillips DATE 7 APR 2011
CHECKED BY JJ DATE 7 APR 2011
CALTROP Corporation 3400 Lakeside Drive, Suite 525, Miramar, FL 33027
Z9 = 900
(ASCE Table 6-2)
Zmin = 15 (ASCE Table 6-2)
a = 9.5
(ASCE Table 6-21
S = 0.2 (ASCE Table 6-2)
e = 500
(ASCE fable 6-2)
ZBAR = 18 (ASCE 6.5.8.1)
c = 0.2
(ASCE Table 6-2)
=
1.00
(Importance Factor, I from ASCE Table 6-1)
G =
0.91
(Gust Factor, ASCE EQ. 6-4)
KZ =
0.98
(Coefficient from ASCE Table 6-3)
Kn =
1.0
(Topographic Factor from ASCE Figure 6-4)
Kd =
0.85
(Directionality Factor from ASCE Table 6-4)
Velocity Pressure
qZ = 0.00256(V2)(I)(KZ)(Kn)(Kd) (ASCE EQ. 6-15)
qz = 36.1 psf
(Wind Load
H/D =
25
Cf =
1.2 (ASCE Figure 6-21)
Af =
1.44
FFRONT =
108 I bs (Total Lateral Force, ASCE Eq. 6-28)
PFRONT =
18.0 plf (Total Lateral Pressure)
W
a
a
Z = 18 (Effective Height)
LZ = 443 (ASCE EQ. 6-7)
lz = 0.22 (ASCEEQ. 6-5)
GROUND LEVEL
Q = 0.98 (ASCE EQ. 6-6)
T = 1.9 (ASCE 6.5.15,1)
Ibs
AT
— ---
-
--
_._
�
J
26
I
I
'I
W
a L
.K 4
z
I
�tl3
w�.
10,
rsf
I
I
f
a
7
20
-i,aY,—
. 6
I
I
-�Q
C�I�
tI
l�
- �
R51j
���
inn
��
�• r��
I
(
I
I
Z3-
-f
I
I
I
ZZ
I
�
i
36
I
I
h
�
D
� (136�a�d,
6 • s,
nj
c
I
--' Company name:
Project: A11014A Date:4/7/2011
Version: 2.0.4099.27917 Project number: 11-441.37 Page: 116
Project data:
Company name:
Project name: A11014A
Name of the project engineer: M. Phillips
Topic: Antenna Mast Anchors
Project description:
Remarks:
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines and must be checked for plausibility.
Powers Fasteners, 2 Powers Lane, Brewster, NY 10509, USA, http://www.powers.com/
-- Powers Design 1Company name:
`
Project: A11014A Date:417/2011
/ersion: 2.0.4099.27917 Project number: 11-441.37 Page: 2/6
Geometry:
Load actions: [lb], [ft-lb]
Z
N„
Y
M.
Z
V
_......................' .......... _.....
uy
......... I ....... . .................
M
X
V..
M.
Design loads / actions
NU
0
V UX
0
V uy
288
M UX
-1325
M uy
0
M UZ
0
Eccentric profile
ex = 0.00 inch; ey = 0.00 inch
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines and must be checked for plausibility.
Powers Fasteners, 2 Powers Lane, Brewster, NY 10509, USA, http:/Iwww.powers.com/
-- (Company name:
'RA, Powers D- I
—� Project: A11014A Date: 4/7/2011
Version: 2.0.4099.27917 Project number: 11-441.37 Page: 3/6
Calculations:
Selected anchor: Wedge -Bolt+- 5/8" (2.145) ; hnom 3-1/4", Grade1
Effective embedment depth: hef = 2.15 inch
Approval: ESR-2526 (6/1/2010)
Issued: 6/1/2010
Basic principles design: Design method: ACI 318-05 (Appendix D)
Concrete: Normal weight concrete, uncracked concrete, fc = 3000 psi
Load combination: taken from Section 9.2
Reinforcement: no reinforcement to limit splitting cracks available
Stand-off:
Drilling method:
Drill hole condition
Seismic Loads:
Resultinq anchor forces / load distribution:
none edge reinforcement or < #4 bar
Condition B
not existent
.Hammer drilling
Dry
No
Anchor No
#1
#2
#3
#4
Maximum
Tension load
1309 lb
0 lb
0 lb
1309 lb
1309 lb
Shear load
72 lb
72 lb
72 Ib
72 lb
72 lb
Max. concrete compression strain: 0.07 %o
Max. concrete compression stress: 323 psi
Resulting tension force: 2618 lb
Resulting compression force: 2618 lb
Sum am ry Design proof Demand Capacity Status i
Tension load 2618 lb 4984 lb 0.53 <_ 1.0 /"
Shear load 288 lb 6779 lb 0.04 5 1.0✓ OK
/
I Interaction - - 0.47 < _ 1.0V �
Anchor plate; Material: fyk = 36000 psi
Length x width: 8.00 inch x 8.00 inch
Actual plate thickness: 5.00 inch
Calculated plate thickness: not calculated
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines and must be checked for plausibility.
Powers Fasteners, 2 Powers Lane, Brewster, NY 10509, USA, http://www.powers.com/
— "Company name:
1 '• - i- r
-- Project: A11014A Date:4/7/2011
Version: 2.0.4099.27917 Project number: 11-441.37 Page: 4/6
Design proof tension loading_
Steel strength:
Nsa = 24900 Ib
0 * Nsa = 0 * Nsa = 0.65 * 24900 Ib = 16185 Ib
Nua = 1309 Ib
Design proof: Nua / (0 * Nsa) = 1309 Ib / 16185 Ib = 0.08 <_ 1.00
Concrete strength:
hef
= 2.145 inch
kc
= .24.0
Nb
= kc * fc' 0.5 * hef1.5 = 24.0 * 54.77 * 3.142 = 4130 Ib
ANcO
= 41.22 inch'
ANc
= 76.53 inch'
4/ec,N,x
= 1.000
LPec,N,y
= 1.000
4/ed,N
= 1.000
Wc,N
= 1.00
cac
= 4.00 inch
Wcp,N
= 1.000
4) * Ncbg
= 0 * (ANc/ANcO) Wec,N,x * Wec,N,y * Wed,N * Wc,N * Wcp,N * Nb
= 0.65 * (76.53 / 41.22) * 1.000 * 1.000 * 1.000 * 1.00 * 1.000 * 4130 Ib = 4984 Ib
Nua
= 2618 Ib
Design proof:
Nua / (0 * Ncbg) = 2618 Ib / 4984 Ib = 0.53 <_ 1.00
Design proof shear loading_
Steel strength (without lever arm):
Vsa = 11990 Ib
* Vsa = 0 * Vsa = 0.60 * 11990 Ib = 7194 Ib
Vua = 72 Ib
Design proof: Vua / (0 * Vsa) = 72 Ib / 7194 Ib = 0.01 s 1.00
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines and must be checked for plausibility.
Powers Fasteners, 2 Powers Lane, Brewster, NY 10509, USA, http://www.poWers.com/
Reference
D.5.1
D.5.1.2
D.5.2.2
D.5.2.4
D.5.2.4
D.5.2.5
D.5.2.6
D.5.2.7
D.5.2.1
Reference
D.6.1
D.6.1.2
I
Company name:
Project: A11014A Date:4/7/2011
rersion: 2.0.4099.27917 Project number: 11-441.37 Page: 5/6
Concrete breakout strength, direction y+:
le
= 2.15 inch
do
= 0.63 inch
cal
= 16.00 inch
Vb
=7*(Ie/do)0.2*d00.5*.fc'0.5 *Cal 1.5
= 7 * 1.280 * 0.791 * 54.772 * 64.00 = 24825 Ib
Avco
= 1152.00 inch
Avc
= 321.00 inch
4/ed,V
= 1.000
4/a,V
= 1.000
4/ec,V
= 1.000
4/c,V
= 1.400
0 * Vcbg
= 4) * (Avc / Avco) * LPed,V * 4Ja,V * Wec,V * 4/c,V * Vb
= 0.70 * (321.00 / 1152.00) * 1.000 * 1.000 ` 1.000 ` 1.400 ` 24825 Ib = 6779 Ib
Vua
= 288 Ib
Design proof:
Vua / (4) * Vcbg) = 288 Ib / 6779 Ib = 0.04 <_ 1.00
Pryout strength:
hef = 2.145 inch
kc = 24.0
Nb=kc*fc0.5*hef1.5=24.0*54.77*3.142=41301b
ANc = 142.09 inch'
ANcO
= 41.22 inch
LPec,N,x
= 1.000
4/ec,N,y
= 1.000
4/ed,N
= 1.000
4/cp,N
= 1.000
LPc,N
= 1.000
kcp
= 1.0
*
4)VcP9
_ 0 * (ANc/ANcO) * 4Pec,N,x * 4tec,N,y * Wed,N * 4Jcp,N * 4Pc,N * Nb * kcp
= 0.70 * (142.09 / 41.22) * 1.000 ` 1.000 * 1.000 * 1.000 * 1.000 * 4130 Ib ` 1.0 = 9965 Ib
Vua
= 288 Ib
Design proof:
Vua / (0 * Vcp) = 288 Ib / 9965 Ib = 0.03 <_ 1.00
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines and must be checked for plausibility.
Powers Fasteners, 2 Powers Lane, Brewster, NY 10509, USA, http://www.powers.comf
D.6.2
D.6.2.6
.D.6.2.1 c
D.6.2.5
D.6.2.7
D.6.2.1
D.5.2.2
D.5.2.4
D.5.2.4
D.5.2.5
D.5.2.7
D.5.2.6
D.6.3.1
D.6.3.1
r
�- - Company name:
Project: A11014A Date:4/712011
Version: 2.0.4099.27917 Project number: 11-441.37 Page: 6/6
Combination tension / shear load:
Interaction:
Design proof: (Nt, / (0 * Nn) + V„ / (0 * Vn)) / 1.2 = (0.53 + 0.04) / 1.2 = 0.47 <_ 1.0
Fastening ok!
Warnings. / remarks:
Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines and must be checked for plausibility.
(Powers Fasteners, 2 Powers Lane, Brewster, NY 10509, USA, http://www.powers.com/
•
r �®
Mobile
steick
PGA ST LUCIE PORT ST LUCIE
1916 PERFECT DRIVE
PORT ST LUCIE, FL 34986
A11 014A
PROPOSED INSTALLATION OF ANTENNA
LOCAL MAP
APPROVALS
DESIGN CRITERIA
INDEX OF DRAWINGS
�s t r�
I k
�4 �sn9
v°°'°
s.!
izvI
'IWGE PROVIDED Bt YIOROSOFf STREETS i TRVS AIO �P I j '��l
PROPERTY OWNER
RF ENGINEER
CONSTRUCTION
SITE ACQUISITION
ZONING
NETWORK
OPERATIONS
CONTRACTOR
DESIGN WIND SPEED: 130 MPH ( 3—SECOND GUST)
IMPORTANCE FACTOR: 1.0
EXPOSURE: C
CATEGORY: II
GCpi: 0.00
SHT.
NO
DESCRIPTION
REV.
N0.
T1
TITLE SHEET'
0
C1
NOTES
0
CONTACTS
C2
SITE PLAN
0
C3
EQUIPMENT PLAN
0
APPLICANT
T—MOBILE USA
1300 CONCORD TERRACE
SUITE 200
SUNRISE, FL 33323
PROPERTY OWNER CONTACT:
LANDLORD: PGA RESERVE, INC..
ADDRESS: 1916 PERFECT DRIVE
CITY, STATE, ZIP: PORT LUCIE, FL 34986
C4
ANTENNA LOCATION PLAN
0
C5
ANTENNA AND COAX DETAILS
0
E1
ELECTRICAL NOTES
0
E2
GROUNDING NOTES
0
.
P R 0 P E RTY SUMMARY
E3
UTILITY ROUTING PLAN
0
E4
ELECTRICAL DETAILS
0
FOLIO : 3327-200-0001-000-4
LATITUDE: 2T 18' 34.31" N
LONGITUDE: 80' 25' 45.08" W
ZONING JURISDICTION: ST LUCIE COUNTY
ZONING _CLASSIFICATION: TBD
LEGAL DESCRIPTION
TBD
RF1
RF DATA SHEET
0
RF2
RF PLUMBING DIAGRAM
0
VICINITY MAP
w�! 1i vs \1 li
-- 9TzII
ram= '%'t• "•, F� 1
— NwL of
'
SITE LOCATION ��`{ \� ``11 Put kI
.. '�f SL
`�
ka
'b• q i� r ���%
wc� loco er uc�soPr smcEn a_aPs_m10 �,` r -=! �
APPLICABLE CODES
THE CONTRACTOR WORK SHALL COMPLY WITH ALL APPLICABLE NATIONAL, STATE, AND LOCAL CODES AS ADOPTED BY THE LOCAL
AUTHORITY HAVING JURISDICTION (AHJ) OVER THE LOCATION. THE EDITION OF THE AHJ ADOPTED CODES AND STANDARDS IN
EFFECT ON THE DATE OF CONTRACT AWARD SHALL GOVERN THE DESIGN.
BUILDING CODE: FLORIDA BUILDING CODE (FBC) 2007 WITH 2009 AMENDMENTS.
ELECTRICAL CODE: NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 70. NATIONAL ELECTRICAL CODE, 2008 EDITION.
MECHANICAL CODE: FBC MECHANICAL CODE 2007.
FIRE CODE: 2004 FLORIDA FIRE PREVENTION CODE, LIGHTNING PROTECTION CODE: NFIR 780 EDITION 2000.
THE CONTRACTOR'S WORK SHALL COMPLY WITH THE LATEST EDITION OF THE FOLLOWING STANDARDS. AMERICAN CONCRETE
INSTITUTE (ACI) 318. BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE, AMERICAN INSTITUTE OF STEEL CONSTRUCTION
(AISC), MANUAL OF STEEL CONSTRUCTION, LRFD 13th EDITION. TELECOMMUNICATIONS INDUSTRY ASSOCIATION (TIA) 222—G,
STRUCTURAL STANDARDS FOR STEEL ANTENNA TOWER AND ANTENNA SUPPORTING STRUCTURES: TIA 607, COMMERCIAL BUILDING
GROUNDING AND BONDING REQUIREMENTS FOR TELECOMMUNICATIONS.
INSTITUTE FOR ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE) 81, GUIDE FOR MEASURING EARTH RESISTIVITY. GROUND
IMPEDANCE, AND EARTH SURFACE POTENTIALS OF A GROUND SYSTEM, IEEE 1100 (1999) RECOMMENDED PRACTICE FOR POWERING
AND GROUNDING OF ELECTRONIC EQUIPMENT.
IEEE C62.41, RECOMMENDED PRACTICES ON SURGE VOLTAGES IN LOW VOLTAGE AC POWER CIRCUITS (FOR LOCATION CATEGORY
"C3" AND -HIGH SYSTEM EXPOSURE).
TELCORDIA GR-1275, GENERAL INSTALLATION REQUIREMENTS, TELCORDIA GR-1503, COAXIAL CABLE CONNECTIONS, ANSI T1.311,
FOR TELECOM — DC POWER SYSTEMS — TELECOM, ENVIRONMENTAL PROTECTION.
DRIVING DIRECTIONS
FROM T—MOBILE'S OFFICE, HEAD NORTH AND THEN EAST ON SAWGRASS EXPY FOR 19.8
MILES TO FLORIDA'S TURNPIKE, HEAD NORTH ON TURNPIKE FOR 44.8 MILES TO EXIT 114 (W
INDIANTOWN RD). HEAD EAST ON INDIANTOWN FOR 0.6 MILES TO 1-95, HEAD NORTH ON
1-95 FOR 34.2 MILES TO EXIT 121 (ST LUCIE WEST BLVD), HEAD WEST ON ST LUCIE WEST
BLVD FOR 0.6 MILES, ROAD NAME CHANGES TO RESERVE BLVD, CONTINUE WEST ON
RESERVE BLVD FOR 0.3 MILES TO PERFECT DRIVE, TURN LEFT AND HEAD SOUTHWEST FOR
0.3 MILES TO SITE AT END OF ROAD.
REV
DATE
DESCRIPTION
A
3/8/11
PRELIMINARY
B
3/15/11
REVISED
0
4/7/11
FOR PERMIT
PROJECT NO.: 11-441.37
DRAWN BY.
CHECKED •BY.
C. TELLEZ
M. ABBEY
THIS DRAWING IS COPYRIGHTED AND IS
THE SOLE PROPERTY OF THE OWNER. IT
IS PRODUCED SOLELY FOR USE BY THE
OWNER AND ITS AFFILIATES.
REPRODUCTION OR USE OF THIS DRAWING
AND/OR THE INFORMATION CONTAINED IN
IT IS FORBIDDEN WITHOUT THE WRITTEN
PERMISSION OF THE OWNER
3400 LAKESIDE DRIVE
SUITE 525
MIRAMAR. FL 33027
CERTIFICATE OF AUTHORIZATION 29214
T • •Mobile:
dick toWth f-
130D CONCORD TERRACE
SUITE 200
SUNRISE, FL 33323
0
0. sl13�a = .0`
:lir
O� STATE OFA.
e
°°®s�o oNa41"• �os°®
DATE OF SIGNATURE 4/7/11
PGA ST LUCIE
PORT ST LUCIE
A11014A
1916 PERFECT DRNE
PORT ST LUCIE, FL 34986
SHEET NAME
TITLE SHEET
SHEET NUMBER
T1
1.
FOR THE PURPOSES OF THESE CONSTRUCTION _,._DINGS, THE FOLLOWING DEFINITIONS SHALL APPLY:
1.
THE APPROPRIATE UTILITY LOCATING SERVICES SHALL BE CONTACTED PRIOR TO THE START OF CONSTRUCTION IN ORDER TO VERIFY THE EXACT
LOCATION OF ALL EXISTING UNDERGROUND UTILITIES.
OWNER - T-MOBILE USA
ENGINEER - CALTROP CORPORATION
2.
THE INSTALLATION OF NEW UTILITIES SHALL BE COORDINATED WITH LOCAL AUTHORITIES.
CONTRACTOR - GENERAL CONTRACTOR (CONSTRUCTION)
3.
ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES, WHERE ENCOUNTERED IN THE WORK, SHALL BE PROTECTED AT ALL
2.
PRIOR TO SUBMITTING HIS BID, THE CONTRACTOR SHALL VISIT THE JOB SITE IN ORDER TO (1) VERIFY ALL EXISTING
TIMES. WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SUCH UTILITIES SHALL BE RELOCATED AS DIRECTED BY THE CONSTRUCTION
CONDITIONS, (2) CONFIRM WHETHER ALL DIMENSIONS ARE AS SHOWN ON THE PLANS AND (3) CONFIRM WHETHER THE WORK
MANAGER. EXTREME CAUTION SHALL BE USED WHEN EXCAVATING OR DRILLING PIERS AROUND OR NEAR UTILITIES.
MAY BE ACCOMPLISHED AS SHOWN. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE CONSTRUCTION
MANAGER.
4
RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF LEGALLY.
3.
A 20-FOOT HORIZONTAL CLEARANCE DISTANCE SHALL BE MAINTAINED FROM ALL EXISTING POWER LINES.
5.
ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES THAT INTERFERE WITH THE EXECUTION OF THE WORK SHALL BE
REMOVED AND/OR CAPPED, PLUGGED OR OTHERWISE DISCONTINUED AT POINTS THAT WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK,
4.
THE CONTRACTOR'S USE OF A CONSTRUCTION STAGING AREA SHALL BE COORDINATED WITH THE OWNER WELL IN ADVANCE OF
SUBJECT TO THE APPROVAL OF THE LANDLORD AND/OR LOCAL UTILITIES.
THE CONSTRUCTION START DATE.
6.
DISTURBANCE TO THE EXISTING SITE DURING CONSTRUCTION SHALL BE MINIMIZED.
5.
LABOR, MATERIAL, TOOLS, EQUIPMENT, TRANSPORTATION AND TEMPORARY POWER SERVICES NECESSARY FOR AND INCIDENTAL
TO COMPLETION OF ALL WORK SHALL BE PROVIDED AS INDICATED ON THE DRAWINGS AND/OR AS SPECIFIED HEREIN. LABOR
7.
ANY AREAS OF THE CONSTRUCTION SITE DISTURBED BY THE WORK AND NOT COVERED BY THE TOWER, EQUIPMENT OR DRIVEWAY, SHALL BE
AND MATERIALS SHALL BE FURNISHED AS REQUIRED FOR COMPLETE SYSTEMS, INCLUDING ALL ELEMENTS OBVIOUSLY OR
GRADED TO A UNIFORM SLOPE. SUCH GRADING SHALL CAUSE SURFACE WATER TO FLOW AWAY FROM ANY EQUIPMENT SHELTER AND TOWER AREAS
REASONABLY INCIDENTAL TO A COMPLETE INSTALLATION, WHETHER OR NOT SPECIFICALLY INDICATED ON THE PLANS.
AND THE SOIL SHALL BE STABILIZED TO PREVENT EROSION. EROSION CONTROL MEASURES,IF REQUIRED DURING CONSTRUCTION, SHALL BE IN
CONFORMANCE WITH THE LOCAL GUIDELINES FOR EROSION AND SEDIMENT CONTROL
6.
FOR TASKS REQUIRED TO BE PERFORMED BUT NOT CLEARLY DEFINED OR IDENTIFIED BY THE CONTRACT DOCUMENTS, THE
CONTRACTOR SHALL NOT START WORK ON SUCH TASKS WITHOUT HAVING RECEIVED WRITTEN AUTHORIZATION FROM THE
B.
THE SUB -GRADE SHALL BE COMPACTED AND BROUGHT TO A UNIFORM GRADE PRIOR TO FINISHED SURFACE APPLICATION.
CONSTRUCTION MANAGER TO PROCEED.
9.
BACKFlLL SHALL CONSIST OF CLEAN SAND FILL APPROVED FOR USE BY THE ENGINEER. NO UNAPPROVED MATERIAL WILL BE ALLOWED. CLEAN SAND
7.
THE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS AND EQUIPMENT UNLESS
FILL SHALL BE FREE OF ALL ROOTS, BOULDERS, OR OTHER DELETERIOUS MATERIAL
OTHERWISE INDICATED BY DIMENSIONS OR DETAILS. EXACT EQUIPMENT LOCATIONS MAY BE MODIFIED AS REQUIRED BY ACTUAL
FIELD CONDITIONS. IF THE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, CONTRACTOR SHALL
10.
THE CONTRACTOR SHALL RESTORE ALL DISTURBED AREAS TO EQUAL TO OR BETTER CONDITION THAN ORIGINAL
PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY THE ENGINEER AND THE CONSTRUCTION MANAGER.
11.
SITE SIGNAGE SHALL BE PROVIDED IN ACCORDANCE WITH THE TECHNICAL SPECIFICATIONS FOR SUCH SIGNAGE AS MAY BE CONTAINED IN THESE
8.
THE CONTRACTOR SHALL OBTAIN, PAY FOR AND DELIVER ALL REQUIRED PERMITS, CERTIFICATES OF INSPECTION, INCLUDING
DRAWINGS.
SITE WORK NOTES 12
HAVING JURISDICTION AND SHALL DELIVER SUCH DOCUMENTS
UTILITY TO THE
FEES, ETC.. REQUIRED BY HTHE
OWNERnPRLIOR TO FINAL ACCEPTANCE OFWORKmEs
9.
THE CONTRACTOR'S OPERATIONS SHALL BE CONFINED TO AREAS OF NEW CONSTRUCTION.
1.
ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE ACI 301, ACI 318, ACI 336, ASTM A184, ASTM A185 AND THE DESIGN
AND CONSTRUCTION SPECIFICATION FOR CAST -IN -PLACE CONCRETE.
10.
ALL NECESSARY PROVISIONS SHALL BE MADE TO PROTECT EXISTING IMPROVEMENTS, PAVING, CURBS, GALVANIZED SURFACES,
ETC, AND THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO SAME RESULTING FROM THE CONSTRUCTION WORK.
2.
ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 4,000 PSI AT 28 DAYS, NORMAL WEIGHT, MAXIMUM AGGREGATE
ALL DISTURBED AND DAMAGED AREAS SHALL BE RESTORED TO THEIR ORIGINAL CONDITION OR BETTER UPON COMPLETION OF
SIZE OF 3/4". 0.45 MAX. W/C, a-5" SLUMP, UNLESS NOTED OTHERWISE.
ALL WORK TO THE SATISFACTION OF THE CONSTRUCTION MANAGER.
11.
THE FOLLOWING CLEANUP TASKS SHALL BE PERFORMED AS FOLLOWS: (1) ON A DAILY BASIS, KEEP THE GENERAL AREA
3.
DO NOT IMPOSE SERVICE LOAD (i.e. FLOOR DEAD AND LIVE LOADS, BACKFlLL, ETC.) UNTIL THE CONCRETE HAS REACHED A MINIMUM
CLEAN AND HAZARD FREE, REMOVING ALL WASTE, DEBRIS AND TRASH FROM THE SITE AND DISPOSING OF SAME IN A LEGAL
COMPRESSIVE STRENGTH OF 3000 PSI.
MANNER. (2) UPON COMPLETION, LEAVE THE PREMISES IN A CLEAN CONDITION AND FREE FROM PAINT SPOTS, DUST, OR
SMUDGES OF ANY NATURE.
4.
REINFORCING STEEL SHALL CONFORM TO ASTM A 615, GRADE 60, DEFORMED BARS UNLESS NOTED OTHERWISE.
12.
ALL EQUIPMENT AND MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH THE RESPECTIVE MANUFACTURER'S
RECOMMENDATIONS EXCEPT WHERE IT IS SPECIFICALLY INDICATED OTHERWISE IN THE CONTRACT DOCUMENTS OR WHERE LOCAL
5.
WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185. USE 6x6-1.4XW1.4 W.W.F. ON 6 MIL VAPOR BARRIER. WIRE FABRIC SHALL
CODES OR REGULATIONS TAKE PRECEDENCE.
BE CONTINUOUS, LAPPED ONE CROSS WIRE SPACING PLUS 2" MINIMUM
13.
ALL WORK PERFORMED AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES,
REGULATIONS AND ORDINANCES. THE CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES,
6.
LAP SPLICES SHALL BE 48 BAR DIAMETERS, WIRED TOGETHER, UNLESS NOTED OTHERWISE.
RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY HAVING JURISDICTION OVER THE PERFORMANCE OF THE
WORK. MECHANICAL AND ELECTRICAL SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE MUNICIPAL AND
7.
THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCING STEEL UNLESS SHOWN OTHERWISE ON
UTILITY COMPANY SPECIFICATIONS AS WELL AS LOCAL AND STATE CODES, ORDINANCES AND APPLICABLE REGULATIONS.
DRAWINGS:
14.
THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AT ALL TIMES, USING THE BEST SKILLS AND ATTENTION. HE
CONCRETE CAST AGAINST EARTH ........ 3 IN. CONCRETE NOT EXPOSED TO EARTH OR WEATHER
SHALL BE SOLELY RESPONSIBLE FOR ALL OF THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND
CONCRETE EXPOSED TO EARTH OR WEATHER: OR NOT CAST AGAINST THE GROUND:
PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK, INCLUDING CONTACT AND COORDINATION WITH THE
CONSTRUCTION MANAGER AND WITH THE OWNER'S AUTHORIZED REPRESENTATIVE.
#6 AND LARGER ..........................2 IN. SLAB AND WALL .......................N IN.
#5 AND SMALLER & WWF......... U¢ IN. BEAMS AND COLUMNS.............Uz IN.
15.
WITHIN TEN (10) WORKING DAYS AFTER PROJECT COMPLETION, THE CONTRACTOR SHALL PROVIDE A COMPLETE SET OF
AS -BUILT DRAWINGS, SWEEP TEST, CYLINDER TESTS, LIEN RELEASES, AND OTHER CLOSEOUT DOCUMENTATION AS REQUIRED BY
THE OWNER. ALL SYSTEMS SHALL BE COMPLETELY ASSEMBLED, TESTED, ADJUSTED AND DEMONSTRATED TO BE READY FOR
8,
A -4" CHAMFER SHALL BE PROVIDED AT ALL EXPOSED EDGES OF CONCRETE, UNLESS NOTED OTHERWISE, IN ACCORDANCE WITH ACI
OPERATION PRIOR TO THE OWNER'S ACCEPTANCE.
301 SECTION 4.2.4.
GENERAL NOTES
9.
INSTALLATION OF CONCRETE EXPANSION/WEDGE ANCHOR, SHALL BE PER MANUFACTURER'S WRITTEN RECOMMENDED PROCEDURE. THE
ANCHOR BOLT, DOWEL OR ROD SHALL CONFORM TO MANUFACTURER'S RECOMMENDATION FOR EMBEDMENT DEPTH OR AS SHOWN ON
1.
DESIGN: 2007 FLORIDA BUILDING CODE WITH 2O09 AMENDMENTS.
THE DRAWINGS. NO REBAR SHALL BE CUT WITHOUT PRIOR ENGINEERING APPROVAL WHEN DRILLING HOLES IN CONCRETE. EXPANSION
BOLTS SHALL BE PROVIDED BY RAMSET/REDHEAD OR APPROVED EQUAL
2.
THE CONTRACTOR SHALL COORDINATE ALL PENETRATIONS, CONDUIT, CHAMFERS, AND EMBEDDED ITEMS PRIOR TO CONCRETE
CONCRETE AND REINFORCING STEEL NOTES
14
PLACEMENT AND/OR STEEL ERECTION. THE CONTRACTOR SHALL VERIFY ALL SIZES AND LOCATIONS.
3.
OBSERVATION VISITS TO THE SITE BY THE ENGINEER OR REPRESENTATIVES OF THE ENGINEER MAY BE MADE DURING
CONSTRUCTION. ANY SUPPORT SERVICES PERFORMED HEREIN SHALL BE DISTINGUISHED FROM INSPECTION AND/OR TESTING
1.
ALLOWABLE SOIL FOUNDATION PRESSURE ASSUMED TO BE 2,000 PSF IN ACCORDANCE WITH FBC TABLE 1804.2.
SERVICES PERFORMED BY OTHERS, AND ARE NOT TO BE CONSTRUED AS SUPERVISION AND/OR MANAGEMENT OF
"B"
CONSTRUCTION.
2.
CLASS BACKFlLL SHALL BE CLEAN SAND FILL APPROVED FOR USE BY THE ENGINEER. NO UNAPPROVED MATERIAL WILL
BE ALLOWED. CLEAN SAND FILL SHALL BE FREE OF ALL ROOTS, BOULDERS, OR OTHER DELETERIOUS MATERIAL
4.
THE CONTRACTOR SHALL PROVIDE TEMPORARY ERECTION BRACING AND SHORING OF ALL STRUCTURAL MEMBERS AS REQUIRED
FOR STABILITY OF THE STRUCTURE DURING ALL PHASES OF CONSTRUCTION. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY
3.
SOIL SHALL BE COMPACTED TO 98% OF THE MODIFIED PROCTOR MAXIMUM DRY DENSITY PER ASTM D1557 METHOD C.
THE ENGINEER OF ANY CONDITION WHICH, IN HIS OPINION, MIGHT ENDANGER THE STABILITY OF THE STRUCTURE OR CAUSE
DISTRESS WITHIN THE STRUCTURE.
4.
THE CONTRACTOR SHALL RESTORE ALL DISTURBED AREAS TO EQUAL TO OR BETTER CONDITION THAN ORIGINAL
5.
DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED
BUT ARE OF SIMILAR CHARACTER TO THE DETAILS PRESENTED, SIMILAR DETAILS SHALL BE USED SUBJECT TO THE REVIEW OF
THE ENGINEER.
6.
SUBMIT WRITTEN REQUEST TO THE ENGINEER FOR APPROVAL OF ANY PROPOSED CHANGE TO THE REQUIREMENTS OF THE
CONTRACT DOCUMENTS. SPLICING, CUTTING, NOTCHING OR OTHER ALTERATIONS TO STRUCTURAL MEMBERS ARE NOT
PERMITTED WITHOUT WRITTEN AUTHORIZATION OF THE ENGINEER. ANY UNAUTHORIZED DEVIATION FROM THE CONTRACT
DOCUMENTS, AND CORRECTION THEREOF, IS THE RESPONSIBILITY OF THE CONTRACTOR.
7.
THE MOST STRINGENT REQUIREMENTS APPLY IN CASE OF CONFLICT BETWEEN SPECIFICATIONS, STANDARDS, CODES AND
DRAWINGS.
GENERAL STRUCTURAL NOTES
1,31
SOIL NOTES
5
REV
DATE
I DESCRIPTION
A
3/8/11
1 PRELIMINARY
B
3/15/111
REVISED
0
4/7/11
FOR PERMIT
PROJECT NO.: 11-441.37
DRAWN BY:
CHECKED BY:
C. TELLEZ
M. ABBEY
THIS DRAWING IS COPYRIGHTED AND IS
THE SOLE PROPERTY OF THE OWNER. IT
IS PRODUCED SOLELY FOR USE BY THE
OWNER AND ITS AFFILIATES.
REPRODUCTION OR USE OF THIS DRAWING
AND/OR THE INFORMATION CONTAINED IN
IT IS FORBIDDEN WITHOUT THE WRITTEN
PERMISSION OF THE OWNER.
■ ' ■
3400 LAKESIDE DRIVE
SUITE 525
MIRAMAR, FL 33027
CERTIFICATE OF AUTHORIZATION 29214
T - -Mobile
Stick toWther•
1300 CONCORD TERRACE
SUITE 200
SUNRISE, FL 33323
%®® A •
' No. 68312
07 STATE OF
°t ®90�AA..•��®.
GATE OF SIGNATURE: 4/7/11
PGA ST LUCIE
PORT ST LUCIE
A11014A
1916 PERFECT DRIVE
PORT ST LUCIE, FL 34986
SHEET NAME
NOTES
SHEET NUMBER
C1
EXISTING
GRASSED
AREA
EXISTING CLOCK TOWER
EXISTING
BUILDING
SITE PLANGRAPW SOME 12�
REV
DATE
DESCRIPTION
A
3/8/11
PRELIMINARY
B
3/15/11
REVISED
0
4/7/11
FOR PERMIT
PROJECT NO.: 11-441.37
DRAWN BY:
CHECKED BY:
C. TELLFZ
M. ABBEY
THIS DRAWING IS COPYRIGHTED AND IS
THE SOLE PROPERTY OF THE OWNER. IT
IS PRODUCED SOLELY FOR USE BY THE
OWNER AND ITS AFFILIATES.
REPRODUCTION OR USE OF THIS DRAWING
AND/OR THE INFORMATION CONTAINED IN
IT IS FORBIDDEN WITHOUT" THE WRITTEN
PERMISSION OF THE OWNER. 00
I 3400 LAKESIDE DRIVE
SUITE 525
MIRAMAR. FL 33027
CERTIFICATE OF AUTHORIZATION 29214
T • .Mobile:
stick towthw-
130D CONCORD TERRACE
SUITE 200
SUNRISE, FL 33323
®° No. 68312
dLl
01.•• STATE OF
NV
pp'r�
DATE OF SIGNATURE: 4/7/11
r
PGA ST LUCIE
PORT ST LUCIE
A11014A
1916 PERFECT DRIVE
PORT ST LUCIE, FL 34986
SHEET NAME
SITE PLAN
SHEET NUMBER
C2
EQUIPMENT PLAN
REV
DATE
DESCRIPTION
A
3/8/11
PRELIMINARY
B
3/15/11
REVISED
0
4/7/11
FOR PERMIT
PROJECT NO.: 11-441.37
DRAWN BY:
CHECKED BY-
C. 781 n
M. ABBEY
THIS DRAWING IS COPYRIGHTED AND IS
THE SOLE PROPERTY OF THE OWNER. IT
IS PRODUCED SOLELY FOR USE BY THE
OWNER AND ITS AFFILIATES.
REPRODUCTION OR USE OF THIS DRAWING
AND/OR THE INFORMATION CONTAINED IN
TT IS FORBIDDEN WITHOUT THE WRITTEN
PERMISSION OF THE OWNER
3400 LAKESIDE DRIVE
SUITE 525
MIRAMAR. FL 33027
CERTIFICATE OF AUTHORIZATION 29214
T . •Mobile
stick together'
1300 CONCORD TERRACE
SUITE 200
SUNRISE. FL 33323
,DATE OF SIGNATURE 4/7/11
PGA ST LUCIE
PORT ST LUCIE
A11014A
191E PERFECT DRM
PORT ST LUCIE, FL 34986
SHEET NAME
EQUIPMENT
PLAN
SHEET NUMBER
C3
7MIR
PROPOSED 1'/ CONDUIT FOR
WO COAX TO BE ROUTED
ALONG EXISTING WATER PIPE
TO EQUIPMENT ROOM
EXISTING CLOCK TOWER
EXISTING ACCESS HATCH
EXISTING COLUMN (TYP. OF 4)
PROPOSED )r CONDUIT FOR COAX TO BE
ROUTED VERTICALLY DOWN TO CEILING
C5 PROPOSED T=MOBILE ANTENNA
0
(SEE NOTES)
EXISTING CONDUIT
NOTES:
1. ANTENNA LOCATION SHALL NOT
OBSTRUCT ACCESS HATCH.
2. ANTENNA SHALL BE PAINTED TO
MATCH EXISTING BUILDING.
ANTENNA LOCATION PLAN
REV
DATE
DESCRIPTION
A
3/8/11
PRELIMINARY
B
3/15/11
REVISED
0
4/7/11
FOR PERMIT
PROJECT NO.: 11-441.37
DRAWN BY:
CHECKED BY:
C. TELLEZ
M. ABBEY
THIS DRAWING IS COPYRIGHTED AND IS
THE SOLE PROPERTY OF THE OWNER. IT
IS PRODUCED SOLELY FOR USE BY THE
OWNER AND ITS AFFILIATES.
REPRODUCTION OR USE OF THIS DRAWING
AND/OR THE INFORMATION CONTAINED IN
IT IS FORBIDDEN WITHOUT THE WRITTEN
PERMISSION OF THE OWNER.
3400 LAKESIDE DRIVE
SUITE 525
MIRAMAR. FL 33027
CERTIFICATE OF AUTHORIZATION 29214
T . •Mobile:
Stick togdhef •
1300 CONCORD TERRACE
SUITE 200
SUNRISE, FL 33323
A
No. 68312 • �'Q�
STATE OF
s�
; O R 1 p •
% %IONAL
o®
o° •
ATE OF SIGNATURE 4/7/11
PGA ST LUCIE
PORT ST LUCIE
A11014A
1916 PERFECT DRIVE
PORT ST LUCIE, FL 34986
SHEET NAME
ANTENNA
LOCATION PLAN
SHEET NUMBER
C4
8"
1Y4" r
4
O O PL Y2"x8x0'-8"
TYP. Y4 2%"0 ANTENNA
O
MOUNTING PIPE
00
Yz" THICK
MAX.
STIFFENER
O
PROPOSED T—MOBILE ANTENNA
POWERS
WED
WEDGE —BOLT WITH
(CELLMAX MODEL # CMM—TRI/6515/E2
31'4" EMBED..
(PAINTED TO MATCH EXISTING BUILDING)
CONTRACTOR TO
VERIFY DECK
THICKNESS AND
COMPOSITION.
NOTIFY ENGINEER
OF ANY CONFLICTS.
BASE PLATE DETAIL NTS
2
WALL —MOUNTED COAX DETAIL N
3
2%" ANTENNA MOUNTING PIPE
ASTM A500 GRADE B (Fy = 42 KSI)
COAXIAL CABLE W/ ANDREW
4"0 BOLLARD
STAINLESS STEEL CABLE
(GRAINGER MODEL #
HANGER (OR EQUAL)
3JJG4 OR EQUAL)
e e PL J¢"x8x0'-8"
e
° 1 1000 UNISTRUT CABLE
SUPPORT (OR EQUAL)
Y4 TYP.
Y4 0 TAPCON WITH 3" MIN. EMBED
�4"0 POWERS PE1000
AND ADHESIVE
ANCHORS WITH 6"
EMBED.
® J
�f
ANTENNA MOUNTING DETAIL NTS
1
WALL -MOUNTED COAX SECTION NTS
4
BOLLARD DETAIL NTS
5
REV
DATE
DESCRIPTION
A
3/8/11
PRELIMINARY
B
3/15/11
REVISED
0
4/7/11
FOR PERMIT
PROJECT NO.: 11-441.37
DRAWN BY:
CHECKED BY:
C. TEL LEZ
M. ABBEY
THIS DRAWING IS COPYRIGHTED AND IS
THE SOLE PROPERTY OF THE OWNER. IT
IS PRODUCED SOLELY FOR USE. BY THE
OWNER AND ITS AFFILIATES.
REPRODUCTION OR USE OF THIS DRAWING
AND/OR THE INFORMATION CONTAINED IN
IT IS FORBIDDEN WITHOUT THE WRTTTEN
PERMISSION OF THE OWNER.
3400 LAKESIDE DRIVE
SUITE 525
MIRAMAR. FL 33027
CERRRCATE OF AUTHORIZATION 29214
T • -Mobile
stick together'
1300 CONCORD TERRACE
SUITE 200
SUNRISE. FL 33323
E Al
(j I i
0. 68312 ='®
O STATE OF
e
iv�"•a�O R1p
°°®°� ®ANAL• � ®�o®
DATE OF SIGNATURE: 4/7/11
PGA ST LUCIE
PORT ST LUCIE
A11014A
1916 PERFECT DRIVE
PORT ST LUCIE. FL 34986
SHEET NAME
ANTENNA AND
COAX DETAILS
SHEET NUMBER
C5
A - GENERAL
Al. ALL ELECTRICAL WORK SHALL CONFORM TO THE NATIONAL ELECTRICAL CODE (EDITION ADOPTED BY LOCAL
JURISDICTION) AND APPLICABLE LOCAL CODES.
A2. GROUNDING SHALL COMPLY WITH ARTICLE 250 OF THE NATIONAL ELECTRIC CODE.
A3. ALL ELECTRICAL EQUIPMENT AND ACCESSORIES SHALL BE U.L APPROVED OR LISTED.
A4. ALL POWER WIRING SHALL BE STRANDED COPPER, TYPE THHN/THHW, AND 90 DEGREES C RATED.
A5. GROUNDING ELECTRODE CONDUCTORS SHALL BE BARE, TIN COATED COPPER AND EQUIPMENT GROUND CONDUCTORS
SHALL BE GREEN INSULATED, UNLESS OTHERWISE NOTED.
A6. ALL POWER WIRING SHALL BE INSTALLED IN GALVANIZED RIGID STEEL CONDUIT, PVC, OR FLEXIBLE LIQUIDTIGHT
CONDUIT, AS INDICATED.
A7. CONTRACTOR SHALL OBTAIN ALL PERMITS, PAY PERMIT FEES, AND SCHEDULE INSPECTIONS.
AB. CONTRACTOR SHALL APPLY FOR ELECTRICAL SERVICE AS SOON AS POSSIBLE AND COORDINATE REQUIREMENTS, SERVICE
ROUTING, AND METER SOCKET TYPE WITH LOCAL POWER COMPANY.
A9. CONTRACTOR SHALL APPLY FOR TELEPHONE SERVICE AS SOON AS POSSIBLE AND COORDINATE REQUIREMENTS AND
SERVICE ROUTING WITH TELEPHONE COMPANY.
A10. PROVIDE ALL LABOR AND MATERIAL DESCRIBED ON THIS DRAWING, AND ALL ITEMS INCIDENTAL TO COMPLETING AND
PRESENTING THIS PROJECT AS FULLY OPERATIONAL
A11. WHERE LONG POWER CABLE RUNS PREVAIL, CONTRACTOR SHALL CALCULATE THE VOLTAGE DROP AND SIZE WIRES AND
CONDUIT ACCORDINGLY.
Al2. WHERE TRANSFORMER IS REQUIRED FOR ELECTRICAL SERVICE, TRANSFORMER SECONDARY SHALL BE GROUNDED PER
N.E.C., ARTICLE 250-26.
A13. REFER TO SITE SPECIFIC DWGS FOR ELEVATIONS.
A14. ALL ELECTRICAL DEVICES EXPOSED TO WEATHER SHALL BE OF RAINPROOF CONSTRUCTION AND SHALL REQUIRE WATER
TIGHT CONDUIT HUBS.
A15. CONTRACTOR SHALL COIL CABLES AT HANDHOLE WITH LENGTHS AS REQUIRED BY ELECTRICAL UTILITY FOR CONNECTION
BY UTILITY.
A16. ALL UNDERGROUND SERVICE ENTRANCE POWER CABLES SHALL BE TYPE FOR SUCH USE. CONTRACTOR SHALL
CALCULATE VOLTAGE DROP AND RE -SIZE CABLES PER NEC REQUIREMENTS FOR CABLE RUNS EXCEEDING 250 FEET.
B - POWER CABLE AND SERVICE
B1. CONTRACTOR SHALL PROVIDE CONDUIT AND WIRING TO BTS AND VERIFY EXACT CONDUIT ROUTING. RACEWAY SYSTEM
MATERIALS AND DEVICES FURNISHED SHALL BE IN ACCORDANCE WITH APPLICABLE STANDARDS OF ANSI, NEMA, AND UL
RACEWAY SYSTEM COMPONENTS SHALL BE INSTALLED IN ACCORDANCE WITH APPLICABLE REQUIREMENTS OF THE N.E.C.
B2. A COIL OF WIRE SHALL EXTEND A MINIMUM OF 10 FEET FROM CONDUIT TO PERMIT TERMINATION BY OTHERS.
B3. CONTRACTOR SHALL SEAL AROUND ALL CONDUIT PENETRATIONS THROUGH WALLS, FLOORS AND ROOFS TO PREVENT
MOISTURE PENETRATION OR VERMIN INFESTATION.
B4. CONDUCTORS RUNNING ALONG HORIZONTAL SURFACES (ROOF TOP OR SLAB) SHALL BE INSTALLED IN RIGID CONDUIT
SUPPORTED ON SLEEPERS.
B5. ALL VERTICAL RUNS OF POWER CABLE EXCEEDING 80 FEET IN LENGTH SHALL BE SUPPORTED PER N.E.C. ARTICLE 300
USING KELLEMS GRIPS OR ACCEPTABLE EQUAL CABLE SUPPORT SYSTEM.
86. WHERE A SEPARATE ELECTRICAL SERVICE DROP IS ADDED, CONTRACTOR SHALL INSTALL PERMANENT SERVICE
DISCONNECT OR GROUPING THEREOF, DENOTING ALL OTHER SERVICE ENTRANCES, LOCATION OF EACH AND THE AREAS
SERVED BY EACH.
B7. WHERE ELECTRICAL POWER IS TO BE SUB -FED FROM AN EXISTING DISTRIBUTION SYSTEM, THE FOLLOWING SHALL
APPLY:
A) CONTRACTOR SHALL PERFORM LOAD TESTING TO DETERMINE MAXIMUM FEEDER DEMAND PER N.E.C. ARTICLE
220-35.
B) CONTRACTOR SHALL VERIFY WHETHER EXISTING FEEDER CAPACITY EXCEEDS VALUE CALCULATED PER N.E.C. ARTICLE
220-35
C) EACH BRANCH CIRCUIT PROTECTIVE DEVICE SHALL HAVE SAME INTERRUPTING RATING AS EQUIPMENT SUPPLYING IT.
D) PREFERRED MEANS OF SUPPLY SHALL BE A BRANCH CIRCUIT PROTECTIVE DEVICE LOCATED IN EXISTING PANEL
E) IF A BRANCH CIRCUIT PROTECTIVE DEVICE CANNOT BE OBTAINED OR SPACE IS NOT AVAILABLE, A BRANCH
CIRCUIT MAY BE TAPPED FROM EXISTING FEEDER CONDUCTORS USING AN INSTALLED 2-POLE FUSED DISCONNECT
AND METER BASE PER N.E.C. ARTICLE 240-21 WITH TEN FOOT (10) 'MAXIMUM TAP CONDUCTORS. FUSED
DISCONNECT SHALL BE LISTED SAME OR BETTER INTERRUPTING RATING AS EXISTING SOURCE OF SUPPLY.
ELECTRICAL NOTES
C - RF (COAX) AND LOW VOLTAGE CABLE
Cl. RF CABLES AND LOW VOLTAGE CABLING BETWEEN BTS, LNA OR TMA AND ANTENNA SHALL BE SUPPORTED USING
ANDREW "SNAP -IN" HANGERS OR ACCEPTABLE EQUAL
C2. RF CABLES AND LOW VOLTAGE CABLING BETWEEN BTS, LNA OR TMA AND ANTENNA SHALL BE ROUTED AS
FOLLOWS:
A) RUNNING ALONG HORIZONTAL SURFACES: USE WAVEGUIDE SUPPORTS OR BRIDGE KIT MOUNTED ON
CONCRETE SLEEPERS.
B) RUNNING ALONG VERTICAL TOWER FACE: WAVEGUIDE LADDER W/HANGERS OR KELLEMS GRIPS.
C) RUNNING ALONG OR ADJACENT TO BTS PLATFORM: USE 12 X 3 OPEN OR COVERED ELECTRICAL LADDER
TRAY.
D - IDENTIFICATION
D1. LOCATE NAMEPLATE, MARKING, OR OTHER IDENTIFICATION MEANS ON OUTSIDE EQUIPMENT OR BOX FRONT COVERS.
D2. PROVIDE NAMEPLATE ENGRAVED WITH EQUIPMENT DESIGNATION FOR EACH SAFETY SWITCH AND ALL OTHER
ELECTRICAL CABINETS, ETC.
D3. DURING TRENCH BACK -FILLING FOR EACH UNDERGROUND ELECTRICAL, TELEPHONE, SIGNAL AND COMMUNICATIONS
LINE, PROVIDE A CONTINUOUS UNDERGROUND WARNING TAPE TWELVE INCHES BELOW FINISHED GRADE
REV
DATE
DESCRIPTION
A
3/8/11
PRELIMINARY
B
3/15/11
REVISED
0
4/7/11
FOR PERMIT
PROJECT NO.: 11-441.37
DRAWN BY:
CHECKED BY:
C. TELLEZ
M. ABBEY
THIS DRAWING IS COPYRIGHTED AND IS
THE SOLE PROPERTY OF THE OWNER. IT
IS PRODUCED SOLELY FOR USE BY THE
OWNER AND ITS AFFILIATES.
REPRODUCTION OR USE OF THIS DRAWING
AND/OR THE INFORMATION CONTAINED IN
Ir IS FORBIDDEN WITHOUT THE WRITTEN
PERMISSION OF THE OWNER.
3400 LAKESIDE DRIVE
SUITE 525
MIRAMAR. FL 33027
CERTIFICATE OF AUTHORIZATION 29214
T • -Mobile
Stk* t0whw.
1300 CONCORD TERRACE
SUITE 200
SUNRISE, FL 33323,
E
1.0
W.tl_
No.68312rg
�.q:
fu
0.. STATE OF � ill®
®���ORIV �ev�
S.�oNAL•��?os
LATE OF SIGNATURE: 4/7/11
PGA ST LUCIE
PORT ST LUCIE
All 014A
1916 PERFECT DRIVE
PORT ST LUCIE, FL 34986
SHEET NAME
ELECTRICAL
NOTES
SHEET NUMBER
E1
A - GENERAL
Al. INSTALLATION OF GROUNDING ELECTRODE SYSTEM SHALL COMPLY WITH ARTICLE 250 OF THE NATIONAL ELECTRIC CODE AND WITH ALL
BUILDING CODES OF AUTHORITIES HAVING JURISDICTION.
A2. GROUNDING CONDUCTORS SHALL BE #2 AWG TINNED SOLID BARE COPPER BELOW AND ABOVE GRADE, UNLESS OTHERWISE NOTED
AND SHALL BE ROUTED IN A DOWNWARD PATH TOWARDS GROUND BARS.
A3. GROUNDING CONDUCTORS SHALL BE KEPT AS SHORT AND DIRECT AS POSSIBLE WITH MINIMUM BEND RADIUS OF 12 INCHES.
A4. ALL BELOW GRADE CONNECTIONS SHALL BE CADWELD TYPE CONNECTIONS AND ALL CONNECTIONS TO EQUIPMENT AND GROUND BARS
SHALL BE 2-HOLE BRONZE COMPRESSION CONNECTORS UNLESS OTHERWISE NOTED.
A5. CONTRACTOR SHALL INSTALL NEW PCs GROUNDING SYSTEM PER SPECIFICATIONS AND INTERCONNECT NEW SYSTEMS TO ANY EXISTING
GROUNDING SYSTEMS AS REQUIRED BY NFPA 70 AND 780 (THIS APPLIES TO ELECTRICAL POWER DISTRIBUTION GROUNDING SYSTEM,
LIGHTNING PROTECTION GROUNDING SYSTEM, COAX CABLE GROUNDING SYSTEM AND ANY OTHER EXISTING GROUNDING SYSTEMS).
A6. GROUNDING CONDUCTORS SHALL BE BONDED TO CABLE SUPPORTS, ANTENNA FRAMES, AND ANY SUPPORT FRAMES OR RACKS USING
CADWELD OR MECHANICAL CONNECTIONS.
A7. CONTRACTOR SHALL PROVIDE LOCK WASHERS FOR ALL MECHANICAL CONNECTIONS FOR GROUND CONDUCTORS, STAINLESS STEEL
HARDWARE SHALL BE USED THROUGHOUT.
AS. GROUNDING CONDUCTORS EMBEDDED IN CONCRETE OR PENETRATING WALLS AND FLOORS SHALL BE ENCASED IN PVC CONDUIT. NO
METALLIC CONDUIT SHALL BE USED FOR GROUNDING CONDUCTORS UNLESS REQUIRED BY LOCAL CODES OR OTHERWISE INDICATED
ON DRAWINGS. CONTRACTOR SHALL SEAL AROUND ALL CONDUIT PENETRATIONS TO PREVENT MOISTURE PENETRATION AND VERMIN
INFESTATION.
A9. CONTRACTOR SHALL BOND PCs GROUNDING SYSTEM VIA THE MASTER GROUND BAR TO ALL METAL OBJECTS WITHIN 12 FEET OF
EQUIPMENT, CONDUIT AND CABLES.
AID. BONDING OF GROUNDED CONDUCTOR (NEUTRAL) AND GROUNDING CONDUCTOR SHALL BE AT SERVICE DISCONNECTING MEANS.
BONDING JUMPER SHALL BE INSTALLED PER N.E.C. ARTICLE 250-28.
A11. CONTRACTOR SHALL VERIFY EXACT CONDUIT ROUTING FOR GROUNDING CONDUCTORS WHERE APPLICABLE.
Al2. A GROUND LEAD IS REQUIRED ONLY FOR BTS SUPPORTED ON STEEL FRAME. AN ADDITIONAL GROUND LEAD IS REQUIRED IF CABLE
TRAY IS USED.
Al3. CONNECTIONS TO CGS SHALL BE ARRANGED IN THE FOLLOWING THREE GROUPS:
• SURGE PRODUCERS (COAXIAL CABLE GROUND KITS, TELCO CABINET AND POWER PEDESTAL GROUND).
• SURGE ABSORBERS (GROUNDING ELECTRODE RING OR BUILDING STEEL).
• NON -SURGING OBJECTS (EGB GROUND IN BTS).
A14. DOUBLING OR STACKING OF ANY GROUNDING CONNECTIONS IS NOT ACCEPTABLE.
A15. ALL GROUND BARS SHALL BE INSTALLED WITH STAND OFF INSULATORS.
B - PREPARATION
81. SURFACES: ALL CONNECTIONS SHALL BE MADE TO BARE METAL ALL PAINTED SURFACES SHALL BE FIELD INSPECTED TO ENSURE
PROPER CONTACT. ALL GALVANIZED SURFACES ON WHICH GALVANIZING HAS BEEN REMOVED BY CUTTING, DRILLING, OR ANY OTHER
OPERATION SHALL BE RE -GALVANIZED IN ACCORDANCE WITH ASTM A780 USING "ZINC RICH" COATING AS MANUFACTURED BY ZRC
CHEMICAL PRODUCTS COMPANY (LOCATED IN QUINCY, MASSACHUSETTS). OR ACCEPTABLE EQUAL NO WASHERS ARE ALLOWED
BETWEEN ITEMS BEING GROUNDED. ALL CONNECTIONS ARE TO HAVE A NON -OXIDIZING AGENT ("COPPER SHIELD") APPLIED PRIOR TO
INSTALLATION.
B2. GROUND BAR: ALL COPPER GROUND BARS SHALL, BE CLEANED, POLISHED AND A NON -OXIDIZING AGENT ("COPPER SHIELD")
APPLIED. NO FINGER PRINTS OR DISCOLORED COPPER SHALL BE PERMITTED.
C - BUILDINGS
Cl. ELECTRICAL CONTRACTOR SHALL PERFORM REQUIRED TESTING ON GROUNDING SYSTEM ONCE GROUNDING SYSTEM IS COMPLETELY
CONSTRUCTED AND BEFORE SERVICE POWER AND GROUND IS CONNECTED (SEE NOTE T1 FOR TEST DESCRIPTION).
C2. A #4/0 AWG COPPER CONDUCTOR SHALL BE ROUTED FROM MASTER GROUND BAR' AT BTS SITE TO MAIN METAL COLD WATER PIPE
AND BONDED TO PIPE WITH BRONZE 2-HOLE PIPE CLAMP. CLAMP SHALL BE CONNECTED TO WATER PIPE WITHIN 5 FEET OF ENTRY
OF PIPE INTO BUILDING WITH NO DEVICES BETWEEN ENTRY POINT AND CONNECTION AND SHALL COME IN CONTACT WITH PIPE FOR A
MINIMUM DISTANCE OF 4 INCHES.
C3. METAL RACEWAYS, ENCLOSURES, FRAMES AND OTHER NON -CURRENT CARRYING PARTS OF ELECTRICAL EQUIPMENT SHALL BE KEPT
AT LEAST 6 FEET AWAY FROM LIGHTNING ROD CONDUCTORS OR THEY MUST BE BONDED TO LIGHTING ROD CONDUCTORS AT THE
LOCATION WHERE SEPARATION DISTANCE IS LESS THAN 6 FEET.
C4. A MASTER GROUND BAR (MGB) SHALL BE INSTALLED NEAR BTS WITH BUILDING PRINCIPAL GROUND BAR (BPG) INSTALLED NEAR
ENTRANCE OF MAIN METAL COLD WATER PIPE INTO BUILDING. A #4/0 AWG STRANDED COPPER DOWN CONDUCTOR (VERTICAL
GROUND RISER) SHALL BE USED TO INTERCONNECT GROUND BARS.
C5. VERTICAL RISER SHALL CONSIST OF A #4/0 AWG (THWN) STRANDED COPPER CONDUCTOR INSIDE %4 CONDUIT.
C6. CONTRACTOR SHALL BOND BUILDING PRINCIPAL GROUND BAR (BPG) NEAR MAIN METAL COLD WATER PIPE TO EXISTING BUILDING
GROUND RING AS WELL AS TO MAIN METAL COLD WATER PIPE WITH #4/0 AWG (THWN) STRANDED COPPER CONDUCTOR.
C7. ANTENNA GROUND BARS (AGB) SHALL BE INSTALLED NEAR ANTENNAS AND SHALL BE BONDED TO MASTER GROUND BAR (MGB) WITH
#2 AWG TINNED SOLID BARE COPPER CONDUCTOR.
C8. F CODES REQUIRE VERTICAL RISER TO BE ISOLATED IN CONDUIT, PVC CONDUIT IS PREFERRED. IF METALLIC CONDUIT IS USED,
GROUNDING BUSHINGS SHALL BE INSTALLED ON EACH END OF THE CONDUIT AND BONDED TO GROUND BARS USING #2 AWG (THWN)
STRANDED COPPER CONDUCTORS WITH GREEN INSULATION.
GROUNDING NOTES
D - LAND BUILDS AND CO -LOCATES
D1. THE GROUND ELECTRODE SYSTEM SHALL CONSIST OF DRIVEN GROUND RODS UNIFORMLY SPACED AROUND THE EQUIPMENT
FOUNDATION AND AROUND THE PERIMETER OF THE TOWER FOUNDATION. THE GROUND RODS SHALL BE fib" X 10'-0" COPPER CLAD
STEEL INTERCONNECTED WITH #2 SOLID TINNED BARE COPPER GROUND CONDUCTOR TO FORM A GROUND RING AT A DEPTH
OF 30 INCHES BELOW THE SURFACE OF THE SOIL. A MINIMUM OF 1 FOOT AND A MAXIMUM OF 3 FEET CLEARANCES SHALL BE
MAINTAINED FROM FOUNDATIONS. TOWER AND EQUIPMENT GROUND RINGS SHALL BE INTERCONNECTED WITH TWO GROUNDING
CONDUCTORS OF EQUAL LENGTH AND MATERIALS.
D2. GROUND RODS SHALL BE BONDED TO GROUND RINGS AND INTERCONNECTING CONDUCTORS AT EQUAL INTERVALS OF APPROXIMATELY
10 FEET.
D3. WAVEGUIDE BRIDGE SHALL BE BONDED TO GROUND RINGS OR INTERCONNECTING CONDUCTORS WITH GROUNDING CONDUCTORS
BONDED TO DIAGONALLY OPPOSED SUPPORT POSTS.
D4. GROUND BARS SHALL BE BONDED TO GROUND RING WITH SINGLE GROUNDING CONDUCTOR.
D5. BONDS TO ANTENNA MASTS, FENCE POSTS, WAVEGUIDE BRIDGE, TOWER STEEL (UNLESS PROHIBITED BY TOWER MANUFACTURER) AND
THOSE BELOW GRADE SHALL BE EXOTHERMIC TYPE (CADWELD). ALL OTHER BONDS SHALL BE BRONZE 2-HOLE COMPRESSION
FITTINGS UNLESS OTHERWISE NOTED.
D6. GROUNDING CONDUCTORS MAKING A TRANSITION FROM ABOVE TO BELOW GRADE SHALL BE INSULATED FROM EARTH CONTACT BY
PASSING THROUGH PVC CONDUIT. THE CONDUIT SHALL EXTEND AT LEAST 6 INCHES ABOVE AND 12 INCHES BELOW GRADE LEVEL
E - LIGHTNING PROTECTION
El. IF EXISTING BUILDING HAS AN NFPA 780 AIR TERMINAL SYSTEM, EXISTING SYSTEM SHALL BE BONDED TO A GROUND BAR TO BOND
THE EXISTING SYSTEM TO THE NEW SYSTEM. SHOULD THE EXISTING SYSTEM COME WITHIN 8 FEET OF ANTENNA STRUCTURES,
EXISTING SYSTEM SHALL ALSO BE BONDED TO COAX GROUND BARS.
E2. IF SITE IS IN A HIGH RISK AREA AND ANTENNAS DO NOT FALL WITHIN EXISTING CONE OF PROTECTION FOR BUILDING, AIR TERMINALS
SHALL BE INSTALLED AT ANTENNAS. A SINGLE AIR TERMINAL MAY BE USED WHEN TWO ANTENNAS ARE MOUNTED ON SAME
STRUCTURE AND IT HAS BEEN DETERMINED THAT BOTH ANTENNAS WILL FALL WITHIN LIGHTNING CONE OF PROTECTION FOR SINGLE
AIR TERMINAL
T-MOBILE GROUNDING REQUIREMENTS
T1. CONTRACTOR SHALL INSPECT AND TEST ANY NEW OR EXISTING T-M081LE GROUNDING SYSTEM WITH A RIDDLE-MEGGER TESTER
UTILIZING THE FALL OF POTENTIAL METHOD AND CONTACT CONSTRUCTION MANAGER IF RESISTANCE EXCEEDS 5 OHMS AND SHALL
FIELD MODIFY GROUNDING SYSTEM AS NECESSARY TO ACHIEVE COMPLIANCE. TEST RESULTS AND CONCLUSIONS SHALL BE RECORDED
FOR PROJECT CLOSE-OUT DOCUMENTATION.
T2. COAX CABLE OUTER CONDUCTORS (SHIELDS) SHALL BE GROUNDED USING COAX GROUNDING KITS AT A MINIMUM OF TWO POINTS,
INCLUDING AT ANTENNA AND AT MASTER GROUND BAR. THE COAXIAL CABLE SHALL NOT EXCEED 100 FEET BETWEEN GROUNDING
KITS.
T3. GROUNDING CONDUCTOR CONSISTING OF #2 AWG TINNED SOLID BARE COPPER WIRE .SHALL BE BONDED TO WAVEGUIDE ENTRY
GROUND BAR USING CADWELD CONNECTIONS.
T4. COAX CABLE ENTERING A BUILDING SHALL BE GROUNDED WITH COAX GROUNDING KITS TO AN INSULATED COAX GROUND BAR WHICH
SHALL BE INSTALLED ON THE OUTSIDE FACE OF THE BUILDING, BELOW THE CABLE ENTRY PORTS.
T5. WHEN COAX CABLES ENTER A BUILDING FROM A TOWER, THE COAX GROUND BAR AT THE BUILDING SHALL BE CONNECTED TO THE
EXTERNAL GROUND RING USING #2 AWG BARE TINNED SOLID COPPER ISOLATED IN PVC CONDUIT.
T6. WHEN COAX CABLES ENTER A BUILDING FROM A ROOF TOP, THE COAX GROUND BAR AT THE BUILDING SHALL BE CONNECTED TO
THE MASTER GROUND BAR NEAR THE STS USING #2 AWG STRANDED INSULATED COPPER CONDUCTOR (SEE BUILDINGS NOTES ON
THIS DRAWING FOR CONNECTION TO PRINCIPLE GROUND BAR AND BUILDING GROUND).
REV
DATE
DESCRIPTION
A
3/8/11
PRELIMINARY
B
3/15/11
REVISED
0
4/7/11
FOR PERMIT
L
ECT NO.: 11-441.37
DRAWN BY:
CHECKED BY.,
C. TELLEZ
M. ABBEY
THIS DRAWING IS COPYRIGHTED AND IS
THE SOLE PROPERTY OF THE OWNER. TT
IS PRODUCED SOLELY FOR USE BY THE
OWNER AND ITS AFFILIATES.
REPRODUCTION OR USE OF THIS DRAWING
AND/OR THE INFORMATION CONTAINED IN
TT IS FORBIDDEN WTTHOUT THE WRITTEN
PERMISSION OF THE OWNER.
3400 LAKESIDE DRIVE
SUITE 525
MIRAMAR. FL 33027
CERTIFICATE OF AUTHORIZATION 29214
T • •Mobile --
stick together'
1300 CONCORD TERRACE
SUITE 200
SUNRISE, FL 33323
P� �o?
G• E
No.68312 °• '
l :w•
0 '. STATE OF : 40
s
i • .o to*
4' �S ° O R
®40Is.0IVA L• •�;a®®®e
LATE OF SIGNATURE: 4/7/11
PGA ST LUCIE
PORT ST LUCIE
A11014A
1918 PERFECT DRIVE
PORT ST LUCIE, FL 34986
SHEET NAME
GROUNDING
NOTES
SHEET NUMBER
E2
O1 EXISTING SOOA DISTRIBUTION CENTER
O2 PROPOSED 1Y4"0 CONDUIT FOR POWER
O3 PROPOSED T-MOBILE SUB -METER
O PROPOSED T-MOBILE 100A SUB -PANEL
O PROPOSED T-MOBILE GFI QUAD OUTLET
PROPOSED 19" T—MOBIL
EQUIPMENT RACK W/ GSM AN
UMTS MODULE
NOTE.
PROPOSED CONDUIT ROUTING IS SCHEMATIC ONLY, CONTRACTOR
SHALL DETERMINE SUITABLE ROUTING IN THE FIELD.
REV
DATE
DESCRIPTION
A
3/8/11
PRELIMINARY
B
3/15/11
REVISED
0
4/7/11
FOR PERMIT
PROJECT NO.: 11-441.37
DRAWN BY:
CHECKED BY-
C. TELLEZ
M. ABBEY
THIS DRAWING IS COPYRIGHTED AND IS
THE SOLE PROPERTY OF THE OWNER. R
IS PRODUCED SOLELY FOR USE BY THE
OWNER AND ITS AFFILIATES.
REPRODUCTION OR USE OF THIS DRAWING
AND/OR THE INFORMATION CONTAINED IN
IT IS FORBIDDEN WITHOUT THE WRITTEN
PERMISSION OF THE OWNER.
3400 LAKESIDE DRIVE
SUITE 525
MIRAMAR. FL 33027
CERTIFICATE OF AUTHORIZATION 29214
T Mobile
.Stick together'
1300 CONCORD TERRACE
SUITE 200
SUNRISE, FL 33323,
T'IL1!<R
A
® o
' No. 68312 ='o
fi
:W
0 STATE OF
•� per, ' ® w
✓j� •' � 0 R 1 9
DATE OF SIGNATURE: 4/7/2J
PGA ST LUCIE
PORT ST LUCIE
A11014A
1916 PERFECT DRIVE
PORT ST LUCIE, FL 34986
SHEET NAME'
UTILITY ROUTING
PLAN
SHEET NUMBER
E3
UTILITY ROUTING PLAN _._r_.._ 4 1 I CONSTRUCTION KEY NOTES 2
r.
PANEL E: - o l e
LOCATION: WALL
PANEL RATING 100 AMPS PHASE 1
120/240 VOLTS WIRE 3
_ MCB RATING-100 AMP
MAIN LUG ONLY
NO.
DESCRIPTION
WIRE
GND
COND
COND
GND
WIREAMP
DESCRIPTION
NO.
C
C
1
GFI
0.36
-
-
20/1
#10
#12
3/4"
-
-
SPACE
2
3
SPACE
-
-
-
-
SPACE
4
5
SPACE
-
-
-
-
SPACE
6
7
SPACE
-
-
-
-
SPACE
8
9
SPACE
-
-
-
-
SPACE
10
11
SPACE
-
-
-
-
SPACE
12
SUB TOTAL KVA(CONT)
0
0
0
0
0
0
SUBTOTAL KVA(CONT)
SUB TOTAL KVA(NON-CONT)
0.36
0
0
0
0
1 0
SUB TOTAL KVA(NON-CONT)
TOTAL KVA
NON-CONT+ 125% CONT.
0.4
1.5
TOTAL AMPS
PANEL SCHEDULE 1
PROPOSED T-MOBILE
SUB -METER
1>f SEE NOTE)
EXISTING 800A, 120/208V
DISTRIBUTION CENTER
EXISTING SPARE BREAKER
TO BE UTILIZED BY T=MOBILE
1Y4 C
-'Y4C
-MOBILE 100A.
1 SUB -PANEL
ALL POWER WIRING SHALL BE STRANDED COPPER, TYPE
THHN/THHW, AND 90 DEGREES C RATED:
ELECTRICAL ONE -LINE 12
REV
DATE
DESCRIPTION
A
3/8/11
PRELIMINARY
B
3/15/11
REVISED
0
4/7/11
FOR PERMIT
PROJECT NO.: 11-441.37
DRAWN BY:
CHECKED BY:
C. 1ELLEL
I M. ABBEY
THIS DRAWING IS COPYRIGHTED AND IS
THE SOLE PROPERTY OF THE OWNER. IT
IS PRODUCED SOLELY FOR USE BY THE
OWNER AND ITS AFFILIATES.
REPRODUCTION OR USE OF THIS DRAWING
AND/OR THE INFORMATION CONTAINED IN
IT IS FORBIDDEN WITHOUT THE WRITTEN
PERMISSION OF THE OWNER.
3400 LAKESIDE DRIVE
SUITE 525
MIRAMAR. FL 33027
CERTTFTCATE OF AUTHORIZATION 29214
T • Mobile
stick together-
1300 CONCORD TERRACE
SUITE 200
SUNRISE, FL 33323
t11 4.
♦�p y
No. 68312
O� STATE OFP •• `��/s
isott`�S, < O R I ID ,�� ♦♦�
I[UDATE OF SIGNATURE 4/7/11 J
PGA ST LUCIE
PORT ST LUCIE
A11014A
1916 PERFECT DRIVE
PORT ST LUCIE, FL 34986
SHEET NAME
ELECTRICAL
DETAILS
SHEET NUMBER
E4
ANTENNA & COAX
CABLE SCHEDULE 6AI1014A
Antenna
CL Ht
Coax
Antenna
Above
Antenna
Antenna
Antenna Jumper Color
Coax
# Of
Length
Number
Azimuth
EDT
AGL (ft)
INFR.
Antenna Catalog No.
Port ID
Code
LNA Type
Antenna Assignment
Type
Coax
Coax Label Color/Bands
(ft)
Duplex
STS Jumper Color Code
Al
10-130-250
0
35
Cell Max
CMM-TRI 6515-E2
1-3-4
RR
TX1,TX2,TX3,TX4lRX1,RX2,RX3,RX4
112
1
RR
75
--------
RR
Al
10-130-250
0
35
2 4-6
_
RR(Yellow) _
y ;,
TX1/RX1 : .; .
112
1
RR(Yellow
).
75
---w' -
RR(Yellow)
2C NO
CARRIER CONFIGI 1 1 LATI 27.30953
LONG-80.42919
REQUEST CURRENT RFDS
BEFORE INSTALLATION
R F DATA SHEET
REV
DATE
DESCRIPTION
A
3/8/11
PRELIMINARY
B
3/15/11
REVISED
0
4/7/11
FOR PERMIT
PROJECT NO.: 11-441.37
DRAWN BY.
CHECKED BY:
C. TELLEZ
M. ABBEY
THIS DRAWING IS COPYRIGHTED AND IS
THE SOLE PROPERTY OF THE OWNER. IT
IS PRODUCED SOLELY FOR USE BY THE
OWNER AND ITS AFFILIATES.
REPRODUCTION OR USE OF THIS DRAWING
AND/OR THE INFORMATION CONTAINED IN
IT IS FORBIDDEN WITHOUT THE WRITTEN
PERMISSION OF THE OWNER.
• • ,
3400 LAKESIDE DRIVE
SUITE 525
MIRAMAR. FL 33027
CERTIFICATE OF AUTHORIZATION 29214
T • -Mobile
.stick together'
1300 CONCORD TERRACE
SUITE 200
SUNRISE, FL 33323
1ti?.L!LIL1Lr
' No. 68312
.1
:W
O : STlATE IF : w/
4.6
® R 1 p �� ®♦,
tDATE OF SIGNATURE 4/7/11
PGA ST LUCIE
PORT ST LUCIE
A11O14A
1918 PERFECT DRIVE
PORT ST LUCIE, FL 34986
SHEET NAME
RF DATA
SHEET
SHEET NUMBER
RF1
GSM & UMTS DESIGN
CMM-TRI-6515-E2 /2 COAX/ 6 JUMPERS /9 Node B
REQUEST CURRENT REDS
BEFORE INSTALLATION
REV
DATE
DESCRIPTION
A
3/8/11
PRELIMINARY
B
3/15/11
REVISED
0
4/7/11
FOR PERMIT
PROJECT NO.: 11-441.37
DRAWN BY:
CHECKED BY:
C. TUM
M. ABBEY
THIS DRAWING IS COPYRIGHTED AND IS
THE SOLE PROPERTY OF THE OWNER. IT
IS PRODUCED SOLELY FOR USE BY THE
OWNER AND ITS AFFILIATES.
REPRODUCTION OR USE OF THIS DRAWING
AND/OR THE INFORMATION CONTAINED IN
IT IS FORBIDDEN WITHOUT THE WRITTEN
PERMISSION OF THE OWNER.
3400 LAKESIDE DRIVE
SUITE 525
MIRAMAR. FL 33027
CERTIFlCATE OF AUTHORIZATION 29214
T -Mobile
stick together"
1300 CONCORD TERRACE
SUITE 200 -
SUNRISE, FL 33323
0.68312
0 ' STATE OF .•�N;
s��. * 44 P O�,
♦° S p R I
LATE OF SIGNATURE: 4/7/11)
PGA ST LUCIE
PORT ST LUCIE
A11014A
1916 PERFECT DRIVE
PORT ST LUCIE, FL 34988
SHEET NAME
RF PLUMBING
DIAGRAM
I RF PLUMBING DIAGRAM I 1
SHEET NUMBER
RF2