Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSOFFICE°USE QNLY: DATE FILED: �' PLAN REVIEW FEE: RECEIPT NO.: CONCURRENCY FEE: RECEIPT NO.: PERMIT NUMBER: CERT. CAP. NO.: ALL INFO MUST BE COMPLETE & FILLED IN TO BE ACCEPTED PLANNING & DEVELOPMENT SERVICES DEPARTMENT BUILDING & CODE REGULATIONS DIVISION 2300 Virginia Avenue Ft. Pierce, FL 34982-5652 &CIA 772-462-1553 n 'y 7h 'at e�ci� �cUnt APPLICATION for BUILDING PERMIT y CERTIFICATE of CAPACITY/ZONING COMPLIANCE PROJECT INFORMATION I. LOCATION/SITE ADDRESS: Sal & M A n) C l"q N O SY. 2. PROJECT NAME: SITE PLAN NAME: 3. PROPERTY TAX ID #: 00 — 0 a O Li — 000 — % n 4. LEGAL DESCRIPTION (attach extra sheets if necessary): _ (,t,) A J-¢ 2 I-f1D rV s 74 S-e- O A) i'll--k cA+ i �02 ASsb-a0s-) 5. PLAT BOOK S a 6. PAGE NO. .3 S- 7. BLOCK NO. t' _ 8. LOT NO. I 9. PARCEL SIZE (ACRES/SQ FT.): LOT DIMENSIONS: 10. COMPLETE DESCRIPTION OF CONSTRUCTION PROJECTOR WORK ACTIVITY: Q2 rno V T2 crz 11. SETBACKS (ACTUAL) FRONT: BACK: RIGHT SIDE: LEFT SIDE: 12. TYPE OF CONSTRUCTION (Check all appropriate boxes) [ ] NEW CONSTRUCTION [ ] EXPANSION/ADDITION [ ] INTERIOR RENOVATION [ ] RESIDENTIAL [ ] COMMERCIAL [ ] INDUSTRIAL [ ] OTHER (SPECIFY) 13. DESCRIPTION OF PROPOSED USE: 14. SQ. FT OF CONSTRUCTION: 15. SF. FT 1st FLOOR: 16. VALUE OF CONSTRUCTION: $ ] 000. O O The value of construction is used to determine the amount of permit fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction activities. If the value is $2500 or more, a RECORDED Notice of Commencement must be submitted with this application. SLCCDV Form No.: 001-02 UPDATED 6/25/09 OWNER INFORMATION NAME: MARONDA IIQMrS INC. ADDRESS: 4610 LIPSCOMB ST STE. 1 BAY CITY: PALM STATE: FL ZIP: 32905 PHONE (DAYTIME): (321) 725-5645 Email: NCoofi?eL eM4Zaivd4.P0A% IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE, PLEASE FILL IN NAME AND ADDRESS BELOW. FEE SIMPLE TITLEHOLDER: ADDRESS: CTTY: PHONE (DAYTIME): (_) STATE: CONTRACTOR INFORMATION ST. of FL REG.CERT #: CS C ) a S 31 SS - BUSINESS NAME: MARONDA HOMES INC QUALIFIERS NAME: ILo 6e+� ADDRESS: 4610 LIPSCOMB ST STE 1 ZIP: ST. LUCIE COUNTY CERT #: CITY: PALM BAY STATE: FL ZIP: 32905 PHONE (DAYTIME): G21) 7 7 5- 5 6 4 5 FAX N0.1 1- 7 2 S- S 7 0 3 Email: t P lL /VL I+Qo N c1R _C ARCHIT/ENGINEER: DONALD ROBERTS ADDRESS: 4005 MARONDA WAY CITY: SANFORD PHONE (DAYTIME): ("- J) 3 21 - 0 0-6 4 BONDING COMPANY: ADDRESS: CITY: STATE: FL ZIP: 12771 STATE: MORTGAGE LENDER: BANK OF AMERICA ZIP: ADDRESS: 750 S, ORLANDO AVE STE 202 CITY: WINTER PARK STATE: FL ZIP: 32789 IMPORTANT NOTICE: When a permit is issued and it is not picked up within 60 days after notification it will be voided and returned to you by mail. CERTIFICATION: This application is hereby made to obtain a permit to do the work and installations as indicated, and to obtain a certificate of capacity, if applicable, for the permitted work. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits may be required for ELECTRICAL, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AND AIR CONDITIONERS, FENCES, ETC., not otherwise included with this building permit application. St. Lucie County makes no representation that its granting of a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Homeowner Association rules, bylaws or any covenants that may restrict or prohibit such structure. Please consult with your Homeowner's Association and review your deed for any restrictions which may apply. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures (all types), swimming pools, fences, walls, signs, screen rooms, utility substations & accessory uses to another non- residential use. NOTICE TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOBSITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT., NOTICE TO APPLICANT: IF IT IS NOT YOUR RIGHT, TITLE, AND INTEREST THAT IS SUBJECT TO ATTACHMENT: AS A CONDITION OF ISSUANCE OF THIS PERMIT, YOU PROMISE IN GOOD FAITH TO DELIVER A COPY OF THE CONSTRUCTION LIEN LAW NOTICE TO THE PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT. STATE OF FLO DA STATE OF FLO DA COUNTY OF � Re,) A --e! COUNTY OF The foregoing instrument was acknowledged before me this 14 day of Tu„..g. 20 L , by Q,i CA, A-� A. Oa- Q v w,- J who is personally known aL or has produced as identification. Signatu a of Notafy Commission No. 4115"'MIXOOPER _,; _ MY CON # DD 860358 �— R ,' EXPIRES: February 11, 2013 Bonded Thru Notary Public Underwriters The foregoing instrument was acknowledged before me this i day of 20 11 , by (Z.oe a-�.,� die who is personally known 04- or has produced as identification. Of Commission No. I .116, °kn NAB$'PPER *; MY COMMISSION # DD 860358 EXPIRES: February 11, 2013 Bonded Thru Notary Public Underwriters NOTE: TWO (2) SIGNATURES ARE REQUIRED. EACH SIGNATURE MUST BE NOTARIZED. IF APPLYING FOR THIS BUILDING PERMIT AS AN OWNER/BUILDER, THE OWNER MUST PERSONALLY APPEAR TO SIGN THIS APPLICATION IN THE OFFICE LISTED ON THE FRONT OF THIS APPLICATION. OWNER BUILDER AFFIDAVIT WILL BE REQUIRED FOR ALL OWNER/BUILDER APPLICANTS. For specific instructions see appropriate permit checklist. OFFICE USE ONLY BP #:0 0 SECTION i IP TOWNSHIP 3q RANGE MAP NO. ) f' ZONINGl LAND USE yap l U LOT CVG % TAZ NO. FLOOD ZONE) FIRM MAP # 1ST FLR ELV GT CONST TYPE OCCUP TYPE M CUP # OF FLRS WATER SEWER SPRINKLERS STORMWATER LOT OF REC Before 1/1990 LOT OF REC After 1/1990 LOT SPLIT REQUIRED LOT SPLIT APPROVED REPORT CODE lJJ HABITABLE AREA (RADON) RADON FEE PERMIT FEE LIBRARY IMPACT FEE PUBLIC BLD IMPACT FEE CORRECTION PUBIC BLD IMPACT FEE GENERAL PARKS IMPACT FEE SCHOOL IMPACT FEE ROAD IMPACT FEE CREDIT Y N LAW ENF IMPACT FEE FIRE/EMS IMPACT FEE DRIVEWAY REQUIRED Y N DRIVEWAY FEE ADMINISTRATIVE VARIANCE FEE SPECIFY SUBS REQUIRED MECHANIC ROOF ELECTRIC GAS PLUMBING NON -CONFORMING LOT OF RECORD FEES MISCELLANEOUS FEES DATE SENT TO ADDRESSING: REVIEWS FRONT COUNTER ZONING REVIEW SUPERVISOR REVIEW PLANS REVIEW VEGETATION REVIEW SEA TURTLE REVIEW MANGROVE REVIEW DATE RECEIVED , DATE COMPLETED INITIALS f� Florida -Building Code Online s '• r y r Page 1 of 5 BCIS Home Log In User Registration Hot Topics I Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search .:� Product Approval USER: Public User eaa Product Approval Menu > Product or Application Search > Application List > Application Detail FL # Application Type rf,� Code Version '._2RW Application Status �r�t�i, ER11a Comments DO-aa=@7=5i C-- Archived n-cr-r•� "a Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By FL9174-R7 Revision mF�ILE 'y 2007 Applied For COP V�i�/� ���� o3n Wayne -Dalton, a division of Overhead Door Corp ration 3395 Addison Drive Pensacola, FL 32514 (850) 475-6000 gtaylor@Wayne-Dalton.com Greg Taylor gtaylor@Wayne-Dalton.com Greg Taylor 3395 Addison Drive Pensacola, FL 32514 (850)474-9890 gtaylor@wayne-dalton.com ST, LUC112 COUNTY BUILDINQ DIVISION REVIEWED FOR CO IdCE REVIEWED BY DATE PLANS AND PERMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE Exterior Doors Sectional Exterior Door Assemblies Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received John E. Scates PE-51737 Intertek Testing Services NA Inc. - ETL/Warnock Hersey 06/27/2038 Kurt Dietrich PE Validation Checklist - Hardcopy Received FL9174 R7 COI Cert of Ind Scates 2011 s.odf Standard Year DASMA-108 2002 DASMA-115 2005 http: //www. floridabuilding. org/pr/pr_app_dtl. aspx?param=wGEVXQwtD qufl 1 JRf Wxf6u7... 6/ 17/2011 Florida Building Code Online Page 2 of 5 Sections from the Code Product Approval Method Method 1 Option D Date Submitted 06/16/2011 Date Validated Summary of Products FL # IModel, Number or Name Description 9174.1 5120 / 6100 / 9100 #0228 9' Max width. 8'-9" Max height. Max section height 21". Glazing available in top or intermediate section. Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +26.90/-30.80 Other: FL9174 R7 II 0228 318958 P7.pdf FL9174 R7 II Jamb Connection Supplement P9.pdf FL9174 R7 II Track Supplement Chart P10.pdf Verified By: John E. Scates P.E. FLORIDA PE 51737 Created by Independent Third Party: Yes Evaluation Reports FL9174 R7 AE Eval Rept 9100 rl s.pdf Created by Independent Third Party: Yes 9174.2 / 6100 / 9100 #0229 16' Max width. 8'-9" Max height. Max section height 21". =FE0 Glazing available in top or intermediate section. Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +15.30/-17.00 FL9174 R7 II 0229 318959 P8.Pdf FL9174 R7 II Jamb Connection Supplement P9.pdf FL9174 R7 II Track Supplement Chart P10.1)df Verified By: John E. Scates P.E. FLORIDA PE 51737 Other: Doors with glazing shall not be used in the wind- Created by Independent Third Party: Yes borne debris region unless protected or unless structure is designed as partially enclosed or door is a replacement Evaluation Reports FL9174 R7 AE Eval Rept 9100 rl s.pdf door. Created by Independent Third Party: Yes 9174.3 5120 / 6100 / 9100 #0230 16' Max width. 8'-9" Max height. Max section height 21". Glazing available in top or intermediate section. Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +25.90/-28.80 FL9174 R7 II 0230 318960 P10.pdf FL9174 R7 II Jamb Connection Supplement P9.pdf FL9174 R7 II Track Supplement Chart P10.1)df Verified By: John E. Scates P.E. FLORIDA PE 51737 Other: Created by Independent Third Party: Yes Evaluation Reports FL9174 R7 AE Eva] Rent 9100 r1 s.pdf Created by Independent Third Party: Yes 9174.46100 / 9100 #0231 16' Max width. 8'-9" Max height. Max section height 21". Solid only - no glazing available. Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +30.00/-33.50 FL9174 R7 II 0231 318996 P5.pdf FL9174 R7 II Jamb Connection Supplement P9.pdf FL9174 R7 II Track Supplement Chart P10.Pdf Verified By: John E. Scates P.E. FLORIDA PE 51737 Other: Doors with glazing shall not be used in the wind- Created by Independent Third Party: Yes ,borne debris region unless protected or unless structure is designed as partially enclosed or door is a replacement Evaluation Reports FL9174 R7 AE Eval Rent 9100 rl s.pdf door. Created by Independent Third Party: Yes 9174.5 / 6100 / 9100 #0234 9' Max width. 8'-9" Max height. Max section height 21". =F2O Glazing available in top or intermediate section. Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes FL9174 R7 II 0234 319022 P5.Pdf FL9174 R7 II Jamb Connection Supplement P9.pdf FL9174 R7 II Track Supplement Chart P10.pdf Verified By: John E. Scates P.E. FLORIDA PE 51737 Design Pressure: +43.20/-49.60 Other: Created by Independent Third Party: Yes Evaluation Reports FL9174 R7 AE Eval Rept 9100 rl s.pdf Created by Independent Third Party: Yes 9174.6 / 6100 / 9100 #0235 16' Max width. 8' Max height. Max section height 21". =FE0 Glazing available in top or intermediate section. Limits of Use Installation Instructions http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqufl l JRf Wxf6u7... 6/ 17/2011 Florida Building Code Online I I Page 3 of 5 Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +39.20/-43.70 FL9174 R7 II 0235 319023 P6.pdf FL9174 R7 II 319040 PI Post.pdf FL9174 R7 II Jamb Connection Supplement P9.pdf FL9174 R7 II Track Supplement Chart P10.1)df Verified By: John E. Scates P.E. FLORIDA PE 51737 Other: Created by Independent Third Party: Yes Evaluation Reports FL9174 R7 AE Eval Rept 9100 rl s.odf Created by Independent Third Party: Yes 9174.7 5120 / 9100 #0232 18' Max width. 8'-9" Max height. Max section height 21". Glazing available in top or intermediate section. Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No FL9174 R7 II 0232 318999 P5.Pdf FL9174 R7 II Jamb Connection Supplement P9.odf FL9174 R7 II Track Supplement Chart P10.1)df Verified By: John E. Scates P.E. FLORIDA PE 51737 Design Pressure: +12.40/-13.80 Other: Doors with glazing shall not be used in the wind- Created by Independent Third Party: Yes debris region unless protected or unless structure Evaluation Reports ,borne is designed as partially enclosed or door is a replacement FL9174 R7 AE Eval Rept 9100 rl s.pdf door. Created by Independent Third Party: Yes 9174.8 9100 #0233 19 18' Max width. 8'-9" Max height. Max section height 21". =P0 Glazing available in top or intermediate section. Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes FL9174 R7 II 0233 319000 PS.odf FL9174 R7 II Jamb Connection Supplement P9.pdf FL9174 R7 II Track Supplement Chart P10.pdf Impact Resistant: No Verified By: John E. Scates P.E. FLORIDA PE 51737 Design Pressure: +18.50/-20.70 Other: Doors with glazing shall not be used in the wind- Created by Independent Third Party: Yes borne debris region unless protected or unless structure Evaluation Reports is designed as partially enclosed or door is a replacement FL9174 R7 AE Eval Rept 9100 rl s.pdf door. Created by Independent Third Party: Yes 9174.9 —=]Glazing 5120 / 9100 #0236 18' Max width. 8' Max height. Max section height 21". available in top or intermediate section. Limits of Use Installation Instructions Approved for use in HVHZ: No FL9174 R7 II 0236 319024 P6.Pdf Approved for use outside HVHZ: Yes Impact Resistant: Yes FL9174 R7 II 319040 Pl Post.pdf FL9174 R7 II Jamb Connection Supplement P9.pdf FL9174 R7 II Track Supplement Chart P10.1)df Design Pressure: +30.00/-33.50 Verified By: John E. Scates P.E. FLORIDA PE 51737 Other: Created by Independent Third Party: Yes Evaluation Reports FL9174 R7 AE Eval Rept 9100 rl s.pdf Created by Independent Third Party: Yes 9174.10 / 9100 #0237 18' Max width. 8' Max height. Max section height 21". Tio Glazing available in top or intermediate section. Limits of Use Installation Instructions Approved for use in HVHZ: No FL9174 R7 II 0237 319025 P6.pdf Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +39.20/-43.70 FL9174 R7 II 319040 PI Post.pdf FL9174 R7 II Jamb Connection Supplement P9.Pdf FL9174 R7 II Track Supplement Chart P10.pdf Verified By: John E. Scates P.E. FLORIDA PE 51737 Other: Created by Independent Third Party: Yes Evaluation Reports FL9174 R7 AE Eva] Rept 9100 rl s.pdf Created by Independent Third Party: Yes 9174.11 5120/5140/6100/9100/9400/9600 9' Max width. 10' Max height. Max section height 24". #0600 lGlazing available in top or intermediate section. Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No FL9174 R7 II 0600 319026 P4.pdf FL9174 R7 II Jamb Connection Supplement P9.Pdf FL9174 R7 II Track Supplement Chart P10.1)df Verified By: John E. Scates P.E. FLORIDA PE 51737 Design Pressure: +26.90/-30.80 Other: Doors with glazing shall not be used in the wind- Created by Independent Third Party: Yes borne debris region unless protected or unless structure Evaluation Reports is designed as partially enclosed or door is a replacement FL9174 R7 AE Eval Rept 9100 rl s.pdf door. I Created by Independent Third Party: Yes 9174.12 5120/5140/6100/9100/9400/9600 9' Max width. 10' Max height. Max section height 24" #0601 Glazing available in top or intermediate section. Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes FL9174 R7 II 0601 319027 P4.pdf FL9174 R7 II Jamb Connection Supplement P9.1)df FL9174 R7 II Track Supplement Chart P10.pdf Impact Resistant: Yes Verified By: John E. Scates P.E. FLORIDA PE 51737 Design Pressure: +41.00/-46.30 http://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDqufl l JRf Wxf6u7... 6/ 17/2011 Florida Building Code Online I , r Page 4 of 5 Other: Created by Independent Third Party: Yes Evaluation Reports FL9174 R7 AE Eval Rept 9100 rl s.odf Created by Independent Third Party: Yes 9174.13 —::11#0602 5120/5140/6100/9100/9400/9600 16' Max width. 10' Max height. Max section height 24". Glazing available in top or intermediate section. Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No FL9174 R7 II 0602 319028 P5.odf FL9174 R7 II Jamb Connection Supplement P9.odf FL9174 R7 II Track Supplement Chart P10.odf Verified By: John E. Scates P.E. FLORIDA PE 51737 Design Pressure: +15.30/-17.00 Other: Doors with glazing shall not be used in the wind- Created by Independent Third Party: Yes debris region unless protected or unless structure Evaluation Reports ,borne is designed as partially enclosed or door is a replacement FL9174 R7 AE Eval Rept 9100 rl s.pdf door. Created by Independent Third Party: Yes 9174.14 5120/5140/6100/9100/9400/9600 16' Max width. 10' Max height. Max section height 24". #0603 IGIazing available in top or intermediate section. Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No FL9174 R7 II 0603 319029 P5.pdf FL9174 R7 II Jamb Connection Supplement P9.1)df FL9174 R7 II Track Supplement Chart P10.pdf Verified By: John E. Scates P.E. FLORIDA PE 51737 Design Pressure: +23.00/-25.00 Other: Doors with glazing shall not be used in the wind- Created by Independent Third Party: Yes debris region unless protected or unless structure Evaluation Reports ,borne is designed as partially enclosed or door is a replacement FL9174 R7 AE Eval Rept 9100 rl s.pdf door. Created by Independent Third Party: Yes 9174.15 5120/5140/6100/9100/9400/9600 16' Max width. 8' Max height. Max section height 24" #0604 Glazing available in top or intermediate section. Limits of Use Installation Instructions Approved for use in HVHZ: No FL9174 R7 II 0604 319030 P5.pdf Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +39.20/-43.70 FL9174 R7 II 319040 PI Post.pdf FL9174 R7 II Jamb Connection Supplement P9.1)df FL9174 R7 II Track Supplement Chart P10.pdf Verified By: John E Scates P.E. FLORIDA PE 51737 Other: Created by Independent Third Party: Yes Evaluation Reports FL9174 R7 AE Eval Rept 9100 rl s.pdf Created by Independent Third Party: Yes 9174.16 5120/5140/6100/9100/9400/9600 18' Max width. 10' Max height. Max section height 24". #0605 Glazing available in top or intermediate section. Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No FL9174 R7 II 0605 319031 P4.pdf FL9174 R7 II Jamb Connection Supplement P9.pdf FL9174 R7 II Track Supplement Chart P10.pdf Verified By: John E Scates P.E. FLORIDA PE 51737 Design Pressure: +15.30/-17.00 Other: Doors with glazing shall not be used in the wind- Created by Independent Third Party: Yes borne debris region unless protected or unless structure Evaluation Reports is designed as partially enclosed or door is a replacement FL9174 R7 AE Eval Rept 9100 rl s.pdf door. I Created by Independent Third Party: Yes 9174.17 5120/5140/6100/9100/9400/9600 18' Max width. 8' Max height. Max section height 24" #0606 Glazing available in top or intermediate section. Limits of Use Installation Instructions Approved for use in HVHZ: No FL9174 R7 II 0606 319032 P6.pdf Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +30.00/-33.50 FL9174 R7 II 319040 PI Post.pdf FL9174 R7. II Jamb Connection Supplement P9.odf FL9174 R7 II Track Supplement Chart P10.pdf Verified By: John E Scates P.E. FLORIDA PE 51737 Other: Doors with glazing shall not be used in the wind- borne debris region unless protected or unless structure Created by Independent Third Party: Yes is designed as partially enclosed or door is a replacement door. Evaluation Reports FL9174 R7 AE Eval Rept 9100 rl s.odf Created by Independent Third Party: Yes 9174.18 5120/5140/6100/9100/9400/9600 18' Max width. 8' Max height. Max section height 24" #0609 Solid only - no glazing available. Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +39.20/-43.70 FL9174 R7 II 0609 319035 P5.pdf FL9174 R7 II 319040 Pl Post.pdf FL9174 R7 II Jamb Connection Supplement P9.odf FL9174 R7 II Track Supplement Chart P10.odf Verified By: John E Scates P.E. FLORIDA PE 51737 Other: Created by Independent Third Party: Yes Evaluation Reports FL9174 R7 AE Eval Reot 9100 rl s.odf Created by Independent Third Party: Yes http://www.floridabuilding.org/pr/pT_app_dtl.aspx?param=wGEVXQWtDqun l JRfwxf6u7... 6/ 17/2011 Florida Building Code Online f , 1 Page 5 of 5 9174.19 =F!� 00/9400/9600 #0608 18' Max width. 8'-9" Max height. Max section height 21". Glazing available in top or intermediate section. Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +18.50/-20.70 Other: Doors with glazing shall not be used in the wind- Installation Instructions FL9174 R7 II 0608 319034 P4.pdf FL9174 R7 II Jamb Connection Supplement P9.pdf FL9174 R7 II Track Supplement Chart P10.pdf Verified By:. John E Scates P.E. FLORIDA PE 51737 Created by Independent Third Party: Yes borne debris region unless protected or unless structure is designed as partially enclosed or door is a replacement door. Evaluation Reports FL9174 R7 AE Eval Rept 9100 rl s.pdf Created by Independent Third Party: Yes 9174.20 :��]r4019400/9600 #0607 16' Max width. 8'-9" Max height. Max section height 21". Glazing available in top or intermediate section. Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25.90/-28.80 Other: Doors with glazing shall not be used in the wind- Installation Instructions FL9174 R7 II 0607 319033 P5.pdf FL9174 R7 II Jamb Connection Supplement P9.pdf FL9174 R7 II Track Supplement Chart 1310.1)df Verified By: John E Scates P.E. FLORIDA PE 51737 Created by Independent Third Party: Yes borne debris region unless protected or unless structure designed as partially enclosed or door is a replacement or. Evaluation Reports FL9174 R7 AE Eval Rept 9100 rl s.pdf I Created by Independent Third Party: Yes Back Next Department of Community Affairs Florida Building Code Online Codes and Standards 2555 Shumard Oak Boulevard Tallahassee, Florida 32399-2100 (850) 487-1824, Fax (850) 414-8436 © 2000-2010 The State of Florida. All rights reserved. Privacy Statement I Coovriaht Statement I Accessibility Statement I Plug-in Software I Customer Service Survev I Contact Us Product Approval Accepts: q-�,? Fc,�q eCheck M ' SCCUtit1'S11zTRIC.\' WV., ftl veneer, http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqufllJRf Wxf6u7... 6/17/2011 a John E. Scates, Professional Engineer June 10, 2011 Wayne -Dalton, a Division of Overhead Door Corporation 3395 Addison Dr Pensaco'la, FL 32514 Re: Evaluation Report for Residential Model 5140/9100/9600 family FL 09174-117 To Whom It May Concern: 3121 Fairgate Dr. Carrollton TX 75007 (972) 492-9500 At the request of Wayne -Dalton, a Division of Overhead Door Corporation, I have reviewed the drawings and tests listed below. These doors were tested at an accredited laboratory according to ANSI/DASMA 108-2002 and ANSI/DASMA 115-2005 test procedures. The pressures listed on the drawings are a direct result of these tests. I have concluded that the construction shown on these drawings comply with the structural requirements of the 2007 Florida Building Code. I certify that I meet the requirements of "independence" as detailed in Florida Statute 9N-3.005. Code References 2007 Florida Building Code Section 1609 Section 1609.1.2 Section 1714.5.3.1 Test Procedures Wind Loads ANSI/DASMA 115 - Windborne Debris testing ANSI/DASMA 108 - Static windload testing Testing was conducted in accordance with ANSI/DASMA 108-2002 and 108-2005. ANSI/DASMA 108-2002 is forward compatible with ANSI/DASMA 108-2005. All tests included holding the door at design pressure for a minimum of 10 seconds, and achieving a 150% overload ("test" or "proof") pressure for 10 seconds. In addition, some of the doors were also tested for wndborne debris according to ANSI/DASMA 115-2005. Not all windborne testing included glazing with the door panels. These are itemized in Tables 1 and 2. FL09174-R7 Test Reports ETC-06-976-17575.1, static per 108-02, dated 5/30/2006 ETC-06-976-18185.0, static per 108-02, dated 10/27/2006 ETC-06-976-19011.0, impact per 115-05, dated 4/25/2007- CTLA 1911W static 108-02 and impact 115-05, dated 10/21/2008 CTLA 1911W-3 static 108-02 and impact 115-05, dated 2/10/2009 CTLA 2020W static 108-05 and impact 115-05, dated 3/9/2010 CTLA 2020W-1 static 108-05, dated 3/9/2010 OHD/TREQ ETR 06182-2 static 108-05, dated 5/26/2011 ETC = ETC Laboratories, 297 Buell Rod, Rochester, NY Testing was conducted by ETC at Wayne -Dalton Test Facility in Pensacola, Florida. CTLA = Certified Testing Laboratories, Architectural Division, 7252 Narcoossee Rd., Orlando, FL Testing was conducted by CTLA at Wayne -Dalton Test Facility in Pensacola, Florida. OHD/TREQ= Overhead Door's TREQ facility in Dallas, TX. This facility had a current accreditation per ANSI/IEC/ISO 17025 at the time of testing, listed with International Accreditation Service, Certificate No. TL-368. Installation Instructions The drawings provide installation instructions peculiar to windload reinforcement. In addition, Drawing 307494, Rev P10, provides supplemental track assembly details. Jamb attachment: Methods of securing the door to the mounting surface is detailed in the Jamb Connection Supplement, P/N 324620, Rev P9. This Evaluation Report does not address design of the wall/jambs themselves. These drawings only illustrate common means to attach the door to the jambs. Walls and Jambs should be designed (by others) to withstand the loads imposed by door onto the building. Additional information is available in DASMA Technical Data Sheet TDS-161 at www.dasma.com. r2l__ to/o, Drawings TABLE 1. FL09174-R7 Drawing Option Width Height psf impact Glazing Glazing Static Impact Door Avail Impact Test Test Avail 318958 0228 9 8.75 +26.9/-30.8 Yes Yes Yes 17575 19011 Rev P7 318959 0229 16 8.75 +15.3/-17.0 No Yes No 17575 Rev P8 318960 0230 16 8.75 +25.9/-28.8 Yes Yes Yes 17575 & 19011 Rev P10 1911W3 & ETR6182-2 318996 0231 16 8.75 +30.0/-33.5 Yes No No 1911W 1911W Rev P5 318999 0232 18 8.75 +12.4/-13.8 No Yes No 17575 Rev P5 319000 0233 18 8.75 +18.5/-20.7 No Yes No 17575 Rev P5 319022 0234 9 8.75 +43.2/-49.6 Yes Yes Yes 17575, 19011 & Rev P5 18185 & 1911W3 1911W3 319023 0235 16 8 +39.2/-43.7 Yes Yes Yes 17575 & 19011 Rev P6 18185 319024 0236 18 8 +30.0/-33.5 Yes Yes Yes 17575 & 19011 Rev P6 18185 379025 0237 18 8 +39.2/-43.7 Yes Yes Yes 7575, 19011 & Rev P6 18185 & 1911W3 1911W3 FL 09174-117 TABLE 2. Drawing Option Width Height psf Impact Glazing Glazing Static Impact Door Avail Impact Test Test Avail 319026 0600 9 10 +26.9/-30.8 No Yes No 17575 Rev P4 319027 0601 9 10 +41.0/-46.3 Yes Yes Yes 17575 & 2020W Rev P4 2020W 319028 0602 16 10 +15.3/-17.0 No Yes No 17575 Rev P5 319029 0603 16 10 +23.0/-25.0 No Yes No 17575 Rev P5 319030 0604 16 8 +39.2/-43.7 Yes Yes Yes 17575 & 19011 & Rev P5 2020W 2020W 319031 0605 18 10 +15.3/-17.0 No Yes No 17575 Rev P4 319032 0606 18 8 +30.0/-33.5 No Yes No 17575 & Rev P6 2020W-1 319033 0607 16 8.75 +25.9/-28.8 No Yes No 17575 Rev P5 319034 0608 18 8.75 +18.5/-20.7 No Yes No 17575 Rev P4 379035 0609 18 8 +39.2/-43.7 Yes No No 17575 19011 Rev P5 4 16(lb 0 �� FL 09174-117 Model Descriptions Model 5120/9100 is constructed of 30 gage, ASTM A653-00 CS Type B exterior steel skin with an ASTM A525 G-30 galvanized coating and two coats of polyester paint, a foamed in place polyurethane core, with an interior polylaminate skin, having a thickness of 1.1" for sections with a maximum height of 21" and a thickness of 1.4" for sections with a maximum height of 24". Includes foamed -in -place ribs and a stamped or flush facer design. Model 5140/9400 is constructed of 30 gage, ASTM A653-00 CS Type B exterior steel skin with an ASTM A525 G-30 galvanized coating and two coats of polyester paint, a foamed in place polyurethane core, with an interior polylaminate skin, having a thickness of 1.4" for sections with a maximum height of 24". Includes foamed -in -place ribs and a %" deep recessed facer panel that may use optional decorative trim. Model 9600 is constructed of 30 gage, ASTM A653-00 CS Type B exterior steel skin with an ASTM A525 G-30 galvanized coating and two coats of polyester paint, a foamed in place polyurethane core, with an interior galvanized and painted 32 gage skin, having a thickness of 1.4" for sections with a maximum height of 24". Includes foamed -in -place ribs and a stamped or flush facer design. Model 6100 is constructed of 30 gage, ASTM A653-00 CS Type B exterior steel skin with an ASTM A525 G-30 galvanized coating and two coats of polyester paint, a foamed in place polyurethane core, with an interior polylaminate skin, having a thickness of 1.4" for sections with a maximum height of 24". Includes foamed -in -place ribs and a flush facer design with %" MDF decorative overlay. aps� EAR 5 �b to f tk FL 09174-R7 Additional Limitations The drawings cited above are an explicit part of this evaluation report. The text of this report does not attempt to address all design details, but relies upon the illustrations and text of these drawings and instructions as well. i Selected products within this Evaluation have been tested for Windborne Debris according to ANSI/DASMA 115. Tables 1 and 2 indicate the Windborne Debris doors by a "Yes" in the "Impact Door" column. Doors with available impact glazing are also indicated in these Tables. These products are not intended for the Florida High Velocity Hurricane Zone (HVHZ). Sincerely, Jo n E. Scates, P.E. (4/ Florida PE # 51737®�<< 0 Q 13 GA MIN CONTINUOI WALL ANG PLICE PLATE LOCATION o SEE SCHEDULE s p 14" MAX T 12" MAX 12" MAX I 12" u MAX 12" MAX 12" MAX CLIPS TO BE EITHER RIVETED, BOLTED, OR WELDED. SEE DETAILS THIS PAGE, JOHN E. SCATESI PE 3121 FAIRGATE DR. CARROLLTON, TX 75007 FL PE 51737 TX PE 56308/F2203 PROFESSIONAL ENGINEER'S SEAL PROVIDED ONLY FOR VERIFICATION OF WINDLOAD CONSTRUCTION DETAILS. CLIP DETAIL CLIP LOCATIONS SEE SCHEDULE TRACK 11 GA MIN CLIP SEE SCHEDULE 13 GA MIN CONTINUOUS WALL ANGLE (2) 1 /4" X 7/16 SEMI TUBULAR RIVITS - 11 GA MIN CLIP SEE SCHEDULE - RSW 0.28" 2 13 GA MIN CONTINUOUS WALL ANGLE TRACK (3) 1 /4"-20 TRACK OR CARRIAGE BOLT WITH 1/4"-20 NUT TYPICAL CLIP BOLTING DETAIL TRACK (1) 1 /4"-20 TRACK OR CARRIAGE BOLT WITH 1/4"-20 NUT TYPICAL CLIP RIVETING DETAIL 11 GA MIN CLIP SEE SCHEDULE (1) 1 /4"-20 TRACK OR CARRIAGE BOLT WITH 1/4"-20 NUT TRACK TYPICAL CLIP WELDING DETAIL DESIGN PRESSURE CHART MAX DOOR WIDTH MAX PSF 9'-0" +46.0 PSF -52.0 PSF 18'-0" +46.0 PSF/-52.0 PSF 16'-0" +46.0 PSF/-52.0 PSF Wayne® Salton 3395 ADDISON DRIVE TRACK SUPPLEMENT CHART PEN (850)A47FLRIDA 4 -9890 32514 PG 2 iNCN TRACK -CUPS -TEXAS WALL ANGLE 12 FOOT UPDATED BPJ 6/11/03 P3 UPDATED FORMAT, INCREASED ALLOWABLE PRESSURES TO +46.00/-52.00 PSF FOR ALL DOOR WIDTHS. CHANGED "TEXAS WALL' ANGLE" TO "CONTINUOUS WALL ANGLE". ADDED SUBSTRATE MOUNTING DETAIL, CHANGED TO TITEN HD ANCHORS GRT 4/2/07 P4 CHANGED FORMAT. ADDED MODELS 9800 AND 8024 WITH OVERLAY TO TRACK CLIP SCHEDULE. GRT 8/21/07 P5 UPDATED MODELS LISTED IN CHARTS. UPDATED SPLICE & CLIP SCHEDULES. DLP 9/06/07 P6 UPDATE MOUNTING DETAIL DRAWINGS. GRT 10/05/07 P7 UPDATED CHARTS TO ELIMINATE THE USE OF THE #8 CLIP (REPLACED WITH #9 ACROSS THE BOARD). DLP 10/24/07 P8 UPDATED STEEL MOUNTING DETAIL MRB 04/11/08 P9 EXPANDED 1-1/2- TO 1-3/8" DOOR THICKNESS CHART UP TO 14' HIGH. GRT 12/11/08 P1O UPDATED TITLE BLOCK GRT 6/2/10 SHEET 1 OF 2 DRAWING PART NO. I REV. 307494 P10 EDGE DIST E60XX MIN- 1 /8 2-24 1/8 2-24 MIN 3/16" THICK STEEL FOR MOUNTING 5/16" x 1-5/8" WALL ANGLAAND LAG SCREW OR EQUIVALENT INTO MIN 2 x 6 NO.2 TRACK CLIP SPF (G=0.42) OR - -\DETAIL BETTER AT EACH 1/4-20x9/HOLE OR PAIR OF TRACK BOLHOLE LOCATIONS 1/4-20 HE MOUNTING TO WOOD JAMB DETAIL MOUNTING TO STEEL 2 3/4" OPTIONAL: WALL ANGLE MAY BE MIN EDGE DIST ATTACHED TO SUPPORTING STEEL 4 ° a 4 4ad° a 4. CONCRETE MOUNTING DETAIL JOHN E. SCATESI PE 3121 FNRGATE DR. CARROLLTON, TX 75007 FL PE 51737 TX PE 56308/F2203 PROFESSIONAL ENGINEER'S SEAL PROVIDED ONLY FOR VERIFICATION OF UNDLOAD CONSTRUCTION DETAILS. WITH MIN. (1) 1/4-20x7/8" SELF DRILLING SCREW WITH 1" O.D. WASHER AT EACH HOLE OR PAIR OF HOLE LOCATIONS IN LIEU OF WELDIN( 3/8" SIMPSON TITEN HD, 2-3/4" MIN EMBED INTO MIN 2000 PSI CONCRETE AT EACH HOLE OR PAIR OF HOLE LOCATIONS WALL ANGLE 1/4-20x9/16" TRACK BOLT AND 1/4-20 HEX NUT TRACK CLIP MODELS 8024 8124 WITH DECATRIM OVERLAY (2-1/2" THICK DOOR CLIP #'S FROM BOTTOM TO TOP SPLICEPLATE # 7'-0" 7, 9, 9, 9, 9, 11 16 8'-0" 7, 9, 9, 9, 9, 11, 11 16 9'-0" 7, 9, 9, 9, 9, 11, 11, 11 18 10'-0" 7, 9, 9, 9, 9, 11, 11, 11, 13 18 11'-0" 7, 9, 9, 9, 9, 11, 11, 11, 13, 13 20 12'-0" 7, 9, 9, 9, 9, 11, 11, 11, 13, 13, 13 20 13'-0" 7, 9, 9, 9, 9, 11, 11, 11, 13, 13, 13, 13 22 14' - 0" 7, 9, 9, 9, 9, 11, 11, 11, 13, 13, 13, 13 22 MODELS 5200 8000 8024 8100 8124 8500 2" THICK DOOR CLIP #'S FROM BOTTOM TO TOP SPLICE ATE # 7'-0" 5, 6, 6, 7, 7, 9 12 8'-0" 5, 6, 6, 7, 7, 9, 9 12 9'-0" 5, 6, 6, 7, 7, 9, 9, 9 14 10'-O" 5, 6, 6, 7, 7, 9, 9, 9, 11 14 11'-0" 5, 6, 6, 7, 7, 9, 9, 9, 11, 11 16 12'-0" 5, 6, 6, 7, 7, 9, 9, 9, 11, 11, 11 16 13'-0" 5, 6, 6, 7, 7, 9, 9, 9, 11, 11, 11, 13 18 14'-0" 1 5, 6, 6, 7. 7. 9, 9, 9, 11, 11, 11, 13, 13 18 MODELS 6100 8300 8700 (1-3/8" TO 1-5/8" THICK DOOR HEIGHT CLIP #'S FROM BOTTOM TO TOP SPLICE ATE # 7'-0" 4, 4, 4, 4, 5, 6 8 8'-0" 4, 4, 4, 4, 5, 6, 6 8 9'-0" 4, 4, 4, 4, 5, 6, 6, 7 8 10'-0" 4, 4, 4, 4, 5, 6, 6, 7, 7 8 11 ' - 0 " 4. 4, 4. 4. 5. 6. 6. 7, 7. 9 10 12'-0" 4, 4, 4, 4, 5, 6, 6, 7, 7, 9, 9 10 13'-0" 4, 4, 4, 4, 5, 6, 6, 7, 7, 9, 9, 9 12 14'-0" 4, 4, 4, 4, 5, 6, 6, 7, 7, 9, 9, 9, 9 12 MODELS 9100 9400 9600 9700 9800 1" THICK DOOR HEIGHT CLIP #'S FROM BOTTOM TO TOP SPLICE PA PLATE # 7'-0" 4, 4, 4, 4, 4, 4 6 8'-0" 4, 4, 4, 4, 4, 4, 4 6 9'-0" 4, 4, 4, 4, 4, 4, 4, 4 6 10'-0" 1 4, 4, 4, 4, 4, 4, 4, 4, 4 6 'r2 2 INCH TRACK -CLIPS -TEXAS WALL ANGLE 12 FOOT UPDATED BPJ 6/11/03 P3 UPDATED FORMAT. INCREASED ALLOWABLE PRESSURES TO +46.00/-52.00 PSF FOR ALL DOOR WIDTHS. CHANGED "TEXAS WALL ANGLE" TO "CONTINUOUS" WALL ANGLE". ADDED SUBSTRATE MOUNTING DETAIL, CHANGED TO TITEN HD ANCHORS GRT 4/2/07 P4 CHANGED FORMAT. ADDED MODELS 9800 AND 8024 WITH OVERLAY TO TRACK CLIP SCHEDULE. GRT 8/21/07 P5 UPDATED MODELS LISTED IN CHARTS. UPDATED SPLICE & CUP SCHEDULES. CUP 9/06/07 P6 UPDATE MOUNTING DETAIL DRAWINGS. GRT 10/OS/07 P7 UPDATED CHARTS TO ELIMINATE THE USE OF THE #8 CLIP (REPLACED WITH 99 ACROSS THE BOARD). DLP 10/24/07 P8 UPDATED STEEL MOUNTING DETAIL MRB 04/11/08 P9 EXPANDED 1-1/2" TO 1-3/8" DOOR THICKNESS CHART UP TO 14' HIGH. GRT 12/11/08 P10 ADDED MODEL 8700. UPDATED TITLE BLOCK GRT 6/2/10 Wagner I DATE I NAME Dalton DRAWN 1 1/21/07 GRT CHECKED 8/21/07 MRB SHEET 2 OF 2 3395 ADDISON DRIVE PEN (85O)A474 032514 9890 DRAWING PART NO. 307494 REV. P 10 TRACK SUPPLEMENT CHART II �� WINDLOAD POST P.D. �ay6n87e) DMatl7ton3oppceoeOH 44660 882—6� MODELS www.wayne—dolton.com 5120/5140/6100/9100/9400/9600 INSTALLATION INSTRUCTIONS IMPORTANT NOTICE! READ THE ENCLOSED INSTRUCTIONS CAREFULLY BEFORE INSTALLING THIS WIND LOAD POST. PAY CLOSE ATTENTION TO ALL WARNING LABELS AND NOTES. THIS MANUAL SHOULD BE ATTACHED TO THE WALL IN CLOSE PROXIMITY TO THE WIND LOAD POST. ©Copyright 2006 Wayne —Dalton Corp. Part No. 319040 P1 WIND LOAD POST INSTALLATION INSTRUCTIONS STEP 1: ATTACH THE HEADER LOCK BRACKET TO THE HEADER USING THE (4) 5/16"x1-5/8" LAG SCREWS PROVIDED AS SHOWN IN FIGURE 1. THE HEADER LOCK BRACKET SHOULD BE IN LINE WITH THE INTERMEDIATE HINGES WHERE THE POST IS TO BE INSTALLED AND LOCATED SUCH THAT THE BOTTOM OF THE BRACKET IS APPROXIMATELY 2-1/2" ABOVE THE TOP OF THE DOOR. NOTE: DRYWALL OR ANY OTHER SACRIFICIAL MATERIAL COVERING THE HEADER MUST BE REMOVED PRIOR TO INSTALLING THE HEADER LOCK BRACKET AND REPLACED WITH THE SAME THICKNESS OF WOOD. IF THIS PROCESS IS REQUIRED, THE LENGTH OF THE LAG SCREWS MUST BE INCREASED ACCORDINGLY TO INCLUDE THE THICKNESS OF THE WOOD SO THAT A MINIMUM OF 1-1/2" OF LAG SCREW PENETRATION INTO THE HEADER IS MAINTAINED. STEP 2: ALIGN THE LARGE DIAMETER HOLE IN THE TOP PLATE EXTENSION WITH THE THIRD HOLE IN THE TOP LOCK PLATE AS SHOWN IN FIGURE 1 FOR MODELS 5120/5140/9100/9400/9600 OR THE MIDDLE HOLE AS SHOWN IN FIGURE 2 FOR MODEL 6100 AND BOLT TOGETHER WITH (1) 5/16-18x2-1/2" HEX BOLT AND NUT. ALIGN THE ASSEMBLY OVER THE TOP OF THE INNER POST AND SECURE WITH (4) 5/16-12x1" SELF DRILLING SCREWS THROUGH THE HOLES PROVIDED IN THE TOP LOCK PLATE. SLIDE THE OPPOSITE END OF THE INNER POST INTO ONE END OF THE OUTER POST. STEP 3: PLACE THE POST ASSEMBLY FROM STEP 2 INTO POSITION BY LOWERING THE TOP PLATE EXTENSION INTO THE NOTCH IN THE HEADER LOCK BRACKET UNTIL THE TOP PLATE EXTENSION SEATS IN THE BOTTOM OF THE NOTCH. ALLOW THE OUTER POST TO SLIDE DOWN THE INNER POST UNTIL THE BOTTOM OF THE OUTER POST RESTS ON THE FLOOR. PLUMB THE POST ASSEMBLY. STEP 4: ENSURING THE POST ASSEMBLY IS PLUMB, TRACE THE OUTLINE OF THE BOTTOM OF THE OUTER POST ON THE FLOOR. REMOVE THE POST ASSEMBLY AND SET ASIDE UNTIL STEP 5. LOCATE THE CENTER OF THE TRACED OUTLINE BY CONNECTING THE CORNERS TO FORM AN Y. AT THE INTERSECTION OF THE 'X', DRILL A 5/8" DIAMETER HOLE A MINIMUM OF 3-1/2" DEEP INTO THE FLOOR. CLEAN DUST OUT OF HOLE. STEP 5: ASSEMBLE THE BOTTOM LOCK PLATE BY SLIDING (1) 1/2-13x3-1/2" BOLT DOWN THROUGH THE TOP THE BRACKET AND SECURING WITH THE HEX NUT FROM BELOW. ATTACH THE BOTTOM LOCK PLATE TO THE BOTTOM OF THE OUTER POST WITH (4) 5/16-12x1" SELF DRILLING SCREWS AS SHOWN IN FIGURE 3. HEADER i HEADER LOCK BRACKETS i TOP PLATE EXTENSION TOP LOCK PLATE 2-1/2" (4) 5/16x1-5/8" (4) 5/16-12x1" LAG SCREWS SELF DRILLING --�-- 5/16-18x2-1/2" SCREWS HEX BOLT & NUT FIGURE 1 INNER POST MODELS 5120 5140 9400 9600 TOP PLATE HEADER / - EXTENSION HEADER LOCK � POATEOCK BRACKETS 2-1/2"' I 4) (4) 5/16x1-5/8" 5/16-12x1" LAG SCREWS •'�•• SELF DRILLING SCREWS 5/16-18x2-1/2" HEX BOLT & NUT FIGURE 2 INNER POST MODEL 6100 (3) 1 /4-14x7/8" SELF DRILLING CRIMPTITE SCREWS STRAP ALUMINUM BRACKET POST 5/16" HITCH PIN ' LOCKING STRAP (2) 5/16-12x1" I I SELF DRILLING SCREWS W/ 5/16" FLAT WASHERS BOTTOM 1/2-13x3-1/2" _ . LOCK PLATE HEX BOLT & NUT 1/2-13 HEX NUT (4) 5/16-12x1" FIGURE 3 SELF DRILLING SCREWS -2- I WIND LOAD POST INSTALLATION INSTRUCTIONS (3) 1/4-14x7/8" SELF DRILLING STEP 6: CRIMPTITE SCREWS PLACE THE POST ASSEMBLY INTO POSITION BY LOWERING THE TOP PLATE EXTENSION INTO THE NOTCH IN THE HEADER LOCK BRACKET UNTIL THE TOP PLATE EXTENSION STRAP SEATS IN THE BOTTOM OF THE NOTCH. BRACKET ALLOWING THE OUTER POST TO SLIDE DOWN I THE INNER POST, INSERT THE 1/2-13x3-1/2" BOLT AT THE BOTTOM OF 5/16" LOCKING THE OUTER POST INTO THE HOLE IN THE HITCH PIN STRAP FLOOR. ENSURE THE BOLT IS FULLY INSERTED INTO THE FLOOR. THE NUT ON THE UNDERSIDE OF THE BOTTOM LOCK (2) 5/16-12x1" PLATE MUST REST ON THE FLOOR. SELF DRILLING SCREWS W/ 5/16 STEP 7: FLAT WASHERS ATTACH THE STRAP BRACKETS TO THE TOP SIDE OF THE U—BARS WITH (3) F/GURE 4 1/4-14x7/8" SELF DRILLING CRIMPTITE SCREWS EACH (1) THROUGH THE HOLE IN THE STRAP BRACKET AND THE HOLE IN THE U—BAR AND HINGE AND (2) VERTICALLY I ; INTO THE U—BAR AS SHOWN IN FIGURE 4. EXCEPTION: THE STRAP BRACKET LOCATED ON THE VERY TOP U—BAR MUST BE MOUNTED ON THE UNDERSIDE OF THE STRUT. LAY THE LOCKING STRAPS SIDE BY SIDE AND LOCATE THE SHORT STRAP. BEGINNING WITH THE SHORT STRAP AT THE TOP STRAP BRACKET, PLACE THE STRAP OVER THE i POST AS SHOWN IN FIGURE 4. ALIGN THE ; HOLES IN THE ENDS OF THE STRAP WITH ; THE HOLES IN THE STRAP BRACKET AND INSERT A 5/16" HITCH PIN AS SHOWN. RAISE THE BACK OF THE STRAP UNTIL THE STRAP IS PERPENDICULAR TO THE POST. CONNECT THE STRAP TO THE POST WITH (1) 5/16-12x1" SELF DRILLING SCREW AND FLAT WASHER 1 /4" ABOVE THE STRAP ON THE GARAGE SIDE OF THE POST AND (1) ; 5/16-12x1" SELF DRILLING SCREW AND FLAT WASHER 1/4" BELOW THE STRAP ON THE DOOR SIDE OF THE POST AS SHOWN. DO NOT TIGHTEN THE SCREWS AGAINST THE STRAP. REPEAT FOR THE REMAINING STRAPS. NOTE: THE STRAP IS DESIGNED TO SLIDE FREELY BETWEEN THE SCREWS ALLOWING MOVEMENT OF THE DOOR RELATIVE TO THE POST. DO NOT PLACE THE SCREWS THROUGH THE STRAP OR TIGHTEN THE SCREWS TOO TIGHT RESTRICTING MOVEMENT. AFTER ALL OF THE STRAPS HAVE BEEN INSTALLED, CHECK THE POST TO MAKE SURE IT IS SECURE BY LIFTING UP ON THE POST. IF THE POST RAISES OUT OF THE HEADER LOCK BRACKET, CHECK THE LOCATION OF THE SCREWS ABOVE AND BELOW THE STRAPS. THE GARAGE SIDE SCREWS MUST BE LOCATED ABOVE THE STRAP AS SHOWN IN THE FIGURE 5. STORAGE INSTRUCTIONS AND DECAL INSTALLATION CONTINUED ON PAGE 4 —3— COMPLETED INSTALLATION ON (4) SECTION DOOR FIGURE 5 WIND LOAD POST INSTALLATION INSTRUCTIONS SECURING POSTS FOR STORA GE - STEP 1: LOCATE A CONVENIENT LOCATION AS CLOSE TO THE DOOR AS POSSIBLE AND MOUNT A HEADER LOCK BRACKET TO THE WALL SUCH THAT THE DISTANCE BETWEEN THE BOTTOM OF THE HEADER LOCK BRACKET AND THE FLOOR IS 4" GREATER THAN THE DISTANCE BETWEEN THE FLOOR AND THE BOTTOM OF THE HEADER LOCK BRACKET MOUNTED OVER THE DOOR. THE HEADER LOCK BRACKET FOR STORAGE SHALL BE MOUNTED WITH A MINIMUM OF (2) 5/16"x1-5/8" LAG SCREWS (ONE EACH SIDE) INTO SOLID WOOD. MASONRY ANCHORS MAY BE SUBSTITUTED FOR MOUNTING DIRECTLY TO MASONRY OR CONCRETE. PROVIDE WOOD BLOCKING ADEQUATELY SECURED TO STRUCTURE AS REQUIRED FOR OTHER SUBSTRATES. STEP 2: MOUNT A STRAP BRACKET TO THE WALL IN LINE WITH THE HEADER LOCK BRACKET SUCH THAT THE DISTANCE BETWEEN THE CENTERLINE OF THE HOLE IN THE STRAP BRACKET AND THE FLOOR IS 4" GREATER THAN THE DISTANCE BETWEEN THE CENTERLINE OF THE HOLE IN THE STRAP BRACKET ON THE DOOR AND THE FLOOR WHEN THE DOOR IS FULLY CLOSED. THE STRAP BRACKET FOR STORAGE SHALL BE MOUNTED WITH (2) 5/16"x1-5/8" LAG SCREWS INTO SOLID WOOD. MASONRY ANCHORS MAY BE SUBSTITUTED FOR MOUNTING DIRECTLY TO MASONRY OR CONCRETE. PROVIDE WOOD BLOCKING ADEQUATELY SECURED TO STRUCTURE AS REQUIRED FOR OTHER SUBSTRATES. STEP 3: PLACE THE POST INTO THE STORAGE POSITION BY LOWERING THE TOP PLATE EXTENSION INTO THE NOTCH IN THE HEADER LOCK BRACKET UNTIL THE TOP PLATE EXTENSION SEATS IN THE BOTTOM OF THE NOTCH. SECURE THE BOTTOM LOCKING STRAP TO THE STRAP BRACKET USING THE 5/16" HITCH PIN. PLACE ALL REMAINING HITCH PINS INTO THE REMAINING LOCKING STRAPS FOR STORAGE. INSERT THE PLASTIC PLUG INTO THE HOLE IN THE FLOOR. ATTACHING THE INSTALLATION DECALS AFTER INSTALLATION IS COMPLETE, LOCATE AN OBVIOUSLY VISIBLE LOCATION ON THE INSIDE OF THE GARAGE DOOR AND THE POST AND PLACE THE PROVIDED INSTALLATION LABELS AND TAG ONTO THE DOOR AND POST FOR FUTURE REFERENCE - REFER TO FIGURE 6. IMPORTANT LABELS AND TAG MUST BE ATTACHED TO BOTH DOOR AND POST. 1. APPLIED BY INSTALLER - ONE (1) WIND LOAD PSF LABEL PER DOOR. 2. APPLIED BY INSTALLER - ONE (1) WIND LOAD POST INSTALLATION INSTRUCTIONS LABEL TO BE APPLIED TO INSIDE OF DOOR, NEAR END OF SECOND SECTION. 3. APPLIED BY INSTALLER - ONE (1) EMERGENCY HIGH WIND SITUATIONS TAG TO BE APPLIED TO POST(S) WHEN STORED ON WALL FOR CONSTANT REMINDER TO CONSUMER. -4- 3 O IffevAllimno NOES, 1. NON-!MPACT RESISTANT GLAZING OPTION - .090" MINIMUM SSB GLAZING IN MOLDED FRAMES GLUED WITH A 13 GA HORIZ ANGLE- 1/8- BEAD OF BOSTIK 1100 OR EQUIVALENT UNDER THE OUTER FRAME AND SCREWED TOGETHER WITH A MINIMUM OF (6) #8x1" SCREWS INSTALLED IN TOP OR 13 GA FLAG ANGLE - INTERMEDIATE SECTION (WITH OR WITHOUT DECORATIVE INSERTS) MEETS UNIFORM STATIC DESIGN PRESSURES SHOWN ON THIS DRAWING. GLAZING SHALL HAVE A 16 GA MIN HORIZ- MAXIMUM HEIGHT OF 13.75" AND A MAXIMUM LENGTH OF TRACK 16.75". GLAZING IS NOT IMPACT RESISTANT AND DOES 5/16x1-5/8"- NOT MEET THE REQUIREMENTS FOR WIND-BORNE DEBRIS LAG SCREWS REGIONS. GLAZED SECTION REQUIRES 18 GA J-STRUT (MIN 3 AS SCREWED TO LOWER INTEGRAL RIB OF SECTION AND SHOWN) OPERATOR STILE TO BE FACTORY INSTALLED. INSTALLER SHALL FIELD INSTALL (1) 1/4-14x7/8" SELF DRILLING 16 GA MIN VERT- CRIMPTITE SCREW TO ATTACH THE J-STRUT TO THE TRACK INTEGRAL RIB AND OPERATOR STILE AT THE CENTERLINE OF THE DOOR PER DETAIL F ON SHEET 2. 5/16x1-5/8" LAG- 2. IMPACT RESISTANT GLAZING OPTION - IMPACT SCREW AT EACH RESISTANT GLAZING SYSTEM MAY BE INSTALLED IN TOP JAMB BRACKET OR INTERMEDIATE SECTION (WITH OR WITHOUT DECORATIVE INSERTS). GLAZING SHALL BE 1/4" MAKROLON-AR 1/4-20x9/16" TRACK- POLYCARBONATE OR EQUAL. GLAZING SHALL HAVE A BOLT AND 1/4-20 HEX MAXIMUM HEIGHT OF 15.21" AND A MAXIMUM LENGTH OF NUT AT EACH JB JAMB 50.08". GLAZING IS IMPACT RESISTANT AND DOES MEET BRACKET LOCATION THE REQUIREMENTS FOR WIND-BORNE DEBRIS REGIONS. SEE DETAIL H ON SHEET 2 FOR ASSEMBLY DETAILS. GLAZED SECTION REQUIRES REINFORCEMENT BRACKETS ATTACHED TO U-BAR ON UPPER INTEGRAL RIB (SEE DETAIL J SHEET 2), 18 GA J-STRUT SCREWED TO LOWER INTEGRAL RIB OF SECTION AND OPERATOR STILE TO BE FACTORY INSTALLED. INSTALLER SHALL FIELD INSTALL (1) 1/4-140/8" SELF DRILLING CRIMPTITE SCREW TO ATTACH THE J-STRUT TO THE INTEGRAL RIB AND OPERATOR STILE 15 GA STIFFENED - AT THE CENTERLINE OF THE DOOR PER DETAIL F ON JAMB BRACKETS SHEET 2. SEE SCHELOULE FOR 3. VINYL OR WOOD DOOR STOP NAILED A MAXIMUM OF 6" QUANITY, LOCATION, AND TYPE O.C. MUST OVERLAP TOP AND BOTH ENDS OF PANELS MINIMUM 7/16" TO MEET NEGATIVE PRESSURES. 4. KEY LOCK OR SLIDE LOCKS REQUIRED. KEY LOCK OR SLIDE - LOCK BOTH ENDS (SEE 5. SECTION SHALL BE CONSTRUCTED WITH FOAMED IN NOTE 4). SLIDE LOCK PLACE POLYURETHANE FOAM INSULATION CHEMICALLY SHOWN FOR CLARITY BONDED TO 30 GA MINIMUM FACER STEEL AND A POLYLAMINATE BACKER. END CAP TO HAVE A MINIMUM 1.1" DEPTH. NOTE: (4) SECTION SOLID DOOR SHOWN. 6. THE DESIGN OF THE SUPPORTING STRUCTURAL SEE SHEET 2 FOR ELEMENTS SHALL BE THE RESPONSIBILITY OF THE U-BAR LOCATIONS ON PROFESSIONAL OF RECORD FOR THE BUILDING OR DOORS WITH OTHER STRUCTURE AND IN ACCORDANCE WITH CURRENT BUILDING SECTION QUANTITIES CODES FOR THE LOADS LISTED ON THIS DRAWING. AND SEE NOTES 1 AND 2 ON THIS 7. DOOR JAMB TO BE MINIMUM 2x6 STRUCTURAL GRADE SHEET FOR GLAZING LUMBER. REFER TO JAMB CONNECTION SUPPLEMENT FOR OPTIONS. ATTACHMENT TO SUPPORTING STRUCTURE. 8. LOUVER OPTION - .040" MINIMUM LOUVERS IN MOLDED FRAMES SCREWED TOGETHER WITH A MINIMUM OF (6) Q8x1" SCREWS INSTALLED IN THE BOTTOM SECTION. LOUVERS ARE NOT IMPACT RESISTANT AND DO NOT MEET THE REQUIREMENTS FOR VAND-BORNE DEBRIS REGIONS. LOUVERED SECTION REQUIRES OPERATOR STILE TO BE FACTORY INSTALLED AT THE CENTERLINE OF THE DOOR. l` JOHN E. SCATES, PE 3121 FAIRGATE DR. CARROLLTON, TX 75007 FL PE 51737 TX PE 56308/F2203 ly SEE U-BAR NOTE ON SHEET 2 FOR U-BAR INSTALLATION E REVISIONS PI ADDED SUPERIMPOSED SHEET DESIGN PRESSURE LOADS fE DOOR ON SUPPORTING \1 STRUCTURE AND CLARIFIES NUMBER OF FASTENERS AND CENTER HINGES REQUIRED FOR NARROWER DOOR WIDTHS. MRB 5/10/06 P2 ADDED SHORT PANEL GLAZING OPTION (NOTE 1) • GIRT 6/30/06 18 GA OPERATOR STILE FACTORY P3 ADDED IMPACT ADHERED TO CENTER OF TOP SECTION RESISTANCE TO DOOR. GA END CAP ADDED JB JAMB BRACKET AT 2" LOCATION. ADDED MODEL 6100. MODIFIED NOTE 9 TO STATE THAT LOUVERS ARE NOT IMPACT RESISTANT. GIRT 6/6/07 • P4 MODIFIED JAMB F BRACKET SCHEDULE FOR FAT OPTION. ADDED LHR C SHEET TRACK DETAIL SHEET 2. TYP GIRT 4/17/08 SHEET TYP PS ADDED IMPACT RESISTANT GLAZING. ADDED CONCRETE DETAIL SHEET 2. ADDED TEXAS LICENSE NUMBER TO TITLE BLOCK. CHANGED LOUVEF NOTE. ADDED HIGH LIFT AND ROOF PITCH TRACK NOTE. CRT 7/22/08 P6 UPDATED TITLE BLOCK _ - GIRT 8/26/10 JAMB BRACKET SCHEDULE DOOR HEIGHT NO. OF SECTIONS NO. OF JAMB BRACKETS (EACH JAMB) TRACK .RAPE LOCATION OF CENTERLINE OF JAMB BRACKETS MEASURED FROM BOTTOM OF TRACK (ALL DIMENSIONS t 2") 7'-0" 4 5 QI " (JB), 13" (QI), 25-1/2" (JB), 45-1/4" (QI), 63" (JB) 7'-0" 4 5 FAT " (JB), 10" (JB), 25-3/4" (JB), 42" (JB), 63-1/4" (JB) 8'-0- 5 6 QI " (JB), 13" (01), 23" (JB), 34" (JB), 47-1/4" (QI), 67" (01) 8'-0" 5 6 FAT " (JB), 10" (JB), 21-3/4" (JB), 29-3/4" JB), 48" (JB), 66" (JB) > 8'-O"/HIGH LIFT/ROOF PITCH SEE NOTE BELOW NOTE: (JB) FOLLOWING DIMENSION DENOTES SLOTTED JAMB BRACKET ATTACHED TO TRACK WITH 1/4-2Ox9/15" TRACK BOLT AND NUT. (01) FOLLOWING DIMENSION DENOTES QUICK INSTALL JAMB BRACKET INSTALLED IN BUTTERFLY SLOT. NO ADDITIONAL HARDWARE NEEDED 70 ATTACH TO TRACK. yragne® ALL DOORS WITH HIGH LIFT AND/OR ROOF PITCH REQUIRE USE OF CONTINUOUS WALL ANGLE. SEE SUPPLEMENT TRACK CHART FOR Dalton DETAILS. A DIVISION OF OVERHEAD DOOR C 3395 ADDISON DRIVE NOTE: (5) CENTER HINGES PER JOINT NOTE, POST SYSTEM IS TO I REQUIRED ON DOOR WIDTHS GREATER THAN INSTALLED ON THE CENTER 12'-D". (3) CENTER HINGES PER JOINT LINE OF THE DOOR. REQUIRED ON DOOR WIDTHS LESS THAN OR SEE WINDLOAD POST EQUAL TO 12'-0". INSTALLATION INSTRUCTIONS. SUPERIMPOSED DESIGN PRESSURE LOADS ON SUPPORTING STRUCTURE MAX MAX UNIFORM POINT LOAD AT HEADER AN DOOR DOOR LOAD EACH SLAB AT EACH POST WIOTH HEIGHT JAMB PLF LOCATION LBS 7'-0" 157.0/-20B. +1437.3/-1602.3 16'-0" 8'-0" 157.0/-208. +1633.3/-1820.8 7'-0" 157.0/-208. +1257.7/-1402.1 14'-0" 8'-0" +157.0/-208. +1429.2/-1593.2 12'-0" 7'-0" 157.0/-208.0 +107B.O/-1201.7 8'-0" +157.0/-208.0 +1225.0/-1365.6 7 -0 157.0/-208.0 +898.3/-1001.5 10'-0" 8'-0" +157.0/-208.0 +1020.8/-1138.0 STATIC PRESSURE RATINGS APPROVED SIZES SCALE: N.T.S. SIZE: A DESIGN (PSF): +39.20/-43.70 MAX WIDTH: 16'-0" 1 DATE NAME TEST (PSF): +58.80/-65.55 MAX HEIGHT: 8'-0" DRAWN 1 3/3/06 GIRT IMPACT/CYCLIC RATED (YES/NO): YES MAX SECTION HEIGHT: 21" CHECKED 4/6/06 1 MRB MODELS 5120/6100/9100 SHEET 1 OF 2 DRAWING PART NO, REV. 13 GA ADJUSTABLE TOP PLACE U-BAR OVER INTEGRAL RIB 13 GA ADJUSTABLE FIXTURE ATTACHED TO WITH THE (8) PRE -PUNCHED TOP FIXTURE PRE -PUNCHED HOLES HOLES EACH END FACING UPWARD -� IN BOTTOM OF U-BAR AND ATTACH THRU END CAP AT WITH (2) 1/4-14x5/8" EACH END WITH (2) 1/4-14x7/8- CRIMPTITE SCREWS SELF DRILLING CRIMPTITE SCREWS FOR STANDARD TRACK AND (3) 1/4-14x7/8' SELF DRILLING - 0 CRIMPTITE SCREWS FOR LOW HEADROOM TRACK (2 OF WHICH 0 ARE USED TO ATTACHED THE TOP L OW HEADROOM TRACK DETAIL A BRACKET AS SHOWN). PLACE U-BAR OVER INTEGRAL DETAIL A RIB WITH THE (8) PRE -PUNCHED HOLES EACH END FACING UPWARD USED ONLY ON IMPACT '' 1 AND ATTACH THRU END CAP AT GLAZED SECTION - 11 13 GA ROLLER SLIDE ATTACHED TO EACH END WITH (2) 1/4-14x7/8" GA REINFORCEMENT , PRE -PUNCHED HOLES IN TOP OF U-BAR SELF DRILLING CRIMPTITE SCREWS BRACKET ATTACHED WITH (2) 1/4-14x5/B" CRIMPTITE SCREWS. EXCEPTION: U-BAR PLACED WITH (4) 1/4-14x7/8" USE VIEWING HOLE IN SLIDE TO ENSURE OVER TOP RIB ON THE BOTTOM SELF DRILLING ' PROPER ALIGNMENT OF ROLLERS SECTION SHALL ONLY BE CRIMPTITE SCREWS (2 ATTACHED THRU END CAP AT THROUGH BOTH 15 GA HINGE ATTACHED EACH END WITH (1) 1/4-14x7/8" SELF DRILLING CRIMPTITE BRACKET AND U-BAR) WITH (4) 1/4-14x5/8" CRIMPTITE SCREWS (2 OF SCREW LOCATED ON THE BOTTOM FLANGE DETAIL J WHICH ARE FACTORY OF THE U-BAR ATTACHED) 1 N9� DUE TO CLEARANCES (1) 1/4-14x7/8" SELF DRILLING CRIMPTITE \ REQUIRED TO INSTALL SCREWS AT SCREW AT CENTER LINE OF DOOR THRU THE ENDS OF THE U-BARS, ALL J-STRUT & OPERATOR BRACKET. 2" NYLON " U-BARS SHALL BE INSTALLED ON NOTE: J-STRUT & SCREW ONLY REQUIRED STORMGARD ROLLER 0- SECTIONS PRIOR TO INSTALLING ON GLAZED SECTIONS. SEE NOTES 1 & 2 WITH 4-1/2" STEM ROLLER SUDES AND TOP FIXTURE SHEET 1 DETAIL B ON THE U-BARS. SEE ATTACHMENT NOTES ON THIS SHEET. - (3) 1/4-140/8" 18 GA HINGE ATTACHED PLACE U-BAR OVER INTEGRAL SELF DRILLING CRIMPTITE SCREWS WITH (6) 1/4-14x5/8" RIB AND ATTACH WITH (2) CRIMPTITE SCREWS (2 OF 1/4-14x5/8" CRIMPTITE SCREWS STRAP WHICH ARE FACTORY THRU PRE -PUNCHED HOLES AT EACH INTERMEDIATE HINGE BRACKET ATTACHED, 3 OF WHICH ARE FIELD INSTALLED INTO LOCATION (1 THRU FLANGE OF TOP LEAF, AND 1 OF U-BAR AND BOTTOM HINGE LEAF 5/16" WHICH IS FIELD INSTALLED AND 1 THRU WEB OF U-BAR AND HITCH PIN THRU PRE -PUNCHED HOLE INTEGRAL RIB OF SECTION) .. IN U-BAR) EXCEPTION: AT ALL LOCATIONS REQUIRING A STRAP BRACKET, (1) (2) 5/16-12A" DETAIL C R S DDRILLING MPTITE/SCREW WILL BE USED. SCREWS W/ 5/16 FLAT WASHERS 12 GA BOTTOM BRACKET FACTORY ATTACHED WITH 0 (3) 1/4-14x5/8" PLACE U-BAR OVER INTEGRAL RIB CRIMPTITE SCREWS WITH NOTCH DOWN TO CLEAR BOTTOM BRACKET AND ATTACH THRU END CAP AT EACH END WITH (1) 1/4-14x7/8" SELF FOR IMPACT RESISTANCE, DRILLING CRIMPTITE SCREW AS 1/2-130-1, BOTTOM BRACKET MUST BE SHOWN AND USE (1) 1/4-140/8" HEX BOLT & SCREWED TO THE BOTTOM - - SELF DRILLING CRIMPTITE SCREW U-BAR WITH ACROSS THE BOTTOM OF THE (2) 1/4-140/8" SELF DETAIL D BOTTOM U-BAR AT EACH DRILLING CRIMPTITE SCREWS. PRE -PUNCHED HOLE AT EVERY SEE IMPACT BOTTOM BRACKET HINGE LOCATION. USE (1) DETAIL THIS SHEET. 1/4-14x5/8" CRIMPTITE SCREW (4) 5/16-12 AT ALL OTHER PRE -PUNCHED HOLE LOCATIONS. SELF DRILLIN cracwc— JOHN E. SCATES, PE 3121 FAIRGATE DR. CARROLLTON. TX 75007 FL PE 51737 TX PE 56308/F2203 PRO.ESSIONAL ENGINEER- / #Bx3/4" MIN STAINLESS SCREWS WITH STAINLESS - - BACKED RUBBER WASHERS 3-1/2" O.C. MAX 1/8" BEAD GE A SSG400 C SG4000AC I STRUCTURAL SEALANT OR I 1 FACER STEEL— \ � I I NON-STRUCTURAL DECORATIVE INNER WINDOW TRIM — DETAIL FN. , DETAIL F z HEADER REVISIONS TOP PLATE P1 ADDED SUPERIMPOSED HEADER LOCK EXTENSION DESIGN PRESSURE LOADS BRACKET TOP LOCK ON SUPPORTING PLATE STRUCTURE AND CLARIFIEC NUMBER OF FASTENERS HEADER LOCK AND CENTER HINGES BRACKET REQUIRED FOR NARROWER DOOR WIDTHS. MRB 5/10/06 / (4) 5/16xl-5/8 / P2 ADDED SHORT PANEL GLAZING OPTION (NOTE 1) LAG SCREWS GRT 6/30/06 5/16-18x2-1/2" (4) 5/16x1-5/8' HEX BOLT & NUT P3 ADDED IMPACT - RESISTANCE TO DOOR. LAG SCREWS (4) DRILLING ADDED J8 JAMB BRACKET SELF DRILLING 5/15-18x2-1/2" SCREWS AT 2" LOCATION. ADDED HEX BOLT & NUT MODEL 6100. MODIFIED INNER POST NOTE 9 TO STATE THAT MODELS 5120/9100 MODEL 6100 LOUVERS ARE NOT IMPACT RESISTANT. DETAIL E _GRT 6/6/07. ATTACH BOTTOM BRACKET WITH(5) SECTION DOORS P4 MODIFIED JAMB TO BOTTOM U-BAR WITH (2) 0 0 KSI6U -BARS GA, BRACKET SCHEDULE FOR 1/4-14x7/8" SELF DRILLING LOCATED OVER FAT OPTION. ADDED LHR CRIMPTITE SCREWS INTEGRAL RIBS AS TRACK DETAIL SHEET 2. SHOWN F GRT 4/17/08 (4) SEC110N DOORS P5 ADDED IMPACT WITH 5 3", 20 GA, RESISTANT GLAZING. () ADDED CONCRETE DETAIL - - 80 KSI U-BARS SHEET 2. ADDED TEXAS IMPACT BOTTOM BRACKET LOCATED OVER LICENSE NUMBER TO TITLE (1) 1/4-14x7/8" SELF INTEGRAL RIBS AS L BLOCK. CHANGED LOUVER DRILLING CRIMPTITE SHOWN f ANPITCH AO HIGH LIFT SCREW EACH SIDE OF AND ROOF PITCH TRACK NOTE. STRAP BRACKET (ONLY _ I REQUIRED ON IMPACT GRT 7/22/08 I GLAZED DOOR) \ P6 UPDATED TITLE BLOCK 1�11LOCKING 2500 PSI MIN [<. GRT 8/26/10 STRAP CONCRETE B"X8"MIN 1 TURNDOWN / SLAB AT EDGE 6" MIN L EDGE r ISTANC / ' ALUMINUM CONCRETE DETAIL POST U-BAR ATTACHMENT NOTES 1 1. ALL U-BARS SHALL BE PLACED OVER INTEGRAL RIBS AND ATTACHED THRU PRE -PUNCHED HOLES WITH (2) 1/4-14x5/8" CRIMPTITE SCREWS • AT EACH INTERMEDIATE HINGE LOCATION, (2) 1/4-14x7/8" SELF DRILLING CRIMPTITE SCREWS AT EACH END CAP (EXCEPT BOTH U-BARS \ j ON BOTTOM SECTION - SEE DETAIL B AND D THIS SHEET), (2) 1/4-14x5/8" CRIMPTITE SCREWS APPROXIMATELY MIDWAY BETWEEN END ' OF DOOR AND INTERMEDIATE HINGE LOCATION, AND (1) 1/4-14x5/8" BOTTOM CRIMPTITE SCREW APPROXIMATELY e" FROM EACH END. FOR DOOR LOCK WIDTHS GREATER THAN 12'-0", THERE SHALL BE A TOTAL OF (20) PLATE SCREWS ATTACHING EACH U-BAR EXCEPT BOTH U-BARS ON BOTTOM DETAIL G SECTION SHALL HAVE A TOTAL OF (18) SCREWS EACH. FOR DOOR WIDTHS LESS THAN OR EQUAL TO 12'-0", THERE SHALL BE A TOTAL OF (16) SCREWS ATTACHING EACH U-BAR EXCEPT BOTH U-BARS ON —NON-STRUCTURAL DECORATIVE BOTTOM SECTION SHALL HAVE A TOTAL OF (14) SCREWS EACH. OUTER WINDOW TRIM 2. WITH THE EXCEPTION OF THE (8) PRE -PUNCHED HOLES IN THE TOP \1/4" POLYCARBONATE OF EACH END USED FOR ATTACHMENT OF THE ROLLER SLIDES AND THE \ .1, (6) PRE -PUNCHED HOLES IN THE BOTTOM OF EACH END USED FOR THE ATTACHMENT OF THE TOP FIXTURE AND UNLESS NOTED OTHERWISE ON THIS SPECIFICATION DRAWING, ALL PRE -PUNCHED HOLES IN ALL �I U-BARS SHALL BE ATTACHED TO THE DOOR WITH 1/4-146/8" `{ CRIMPTITE SCREWS. 3. 20 GA U-BARS SHALL BE STAMPED "34" APPROXIMATELY 8" FROM �- EACH END. FL / STATIC PRESSURE RATINGS APPROVED SIZES SCALE: N.T.S. SIZE: A Wagne® DESIGN (PSF): +39.20/-43.70 MAX WIDTH: 16'-0" DATE NAME TEST (PSI): +58.80/-65.55 MAX HEIGHT: 8'-U" DRAWN 3/3/06 GRT Balton IMPACT/CYCLIC RATED (YES/NO): YES MAX SECTION HEIGHT: 21" CHECKED 4/6/06 MRB MODELS 5120/6100/9100 SHEET 2 OF 2 DIVISION OF OVERHEAD DOOR CORP DRAWING PART N0. REV. 3395 ADDISON DRIVE ,\AIINf,'I_OAD .SPF(,'IF'r;" ; `,P T11AI ..f 1f1 n. zS AaQ07