Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SUBMITTED PAPERS
DATE: n—Irl—I I I FEES DUE—"" .0(� I RECEIPT#: _ r 1 Permit#: (/ IN_ -- 1. Location/Site Address: 2. Parcel ID Number: Planning & Development Services D partment Building & Code Regulation Division SCANNED 2300 Virginia Avenue S%f / Ft. Pierce, FL 34982-5652 St. Lucie Tel. 772-462-1553 Count APPLICATION FORg)ROOF PE/ MIT /J /^f' SEE /REVERSE SIDE FlON� ��. Office Use I Section Only Townshi Range MapiPage I Zoning Land Use I Initials (a OE 3zS S If�t 3. Description of Projector Work Activity: 4. Total Roof Area (square feet): `-tag- 5. Roof Pitch: t 6. Type of Roof: [ ] Fiberglass Shingle [ ] Concrete Roof Tile [ ] Wood Shake / Shingle [ ] Tar & Gravel f�f Modified Bitumen [ ] Other [Product Approval required for all types of Roofing Material (2 Sets) [ ] All Commercial Roofing requires design by an Engineer or A chitect (2 Sets) with Product Approval attached ** Roof Mitigation per F.S. 553.844 will be required. 7. Owner Information 8. Contractor I iformation Name:M)��AW� FL Reg/Cer #: OCC05115 3 Address: �W,6& , County Cert#: City: State: (G- Business Name: Mt&& (!o*a r5 Zi p: Phone: �17 �33�" 52 � Cell Phone: too ^M Wlb 9. Value of Construction: S Y'U00 . OD "Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval. CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all of the information contained in this af plication is correct and that all work will be done in compliance with all appligaW laws regulating construction and zoning. 54NOiPA- POEF-T9 0& 4� dL.<� PRINT QUALIFIERS/OWNERS NAME SIGNATURE OF QUALIFIER/OWNER STATE OF FLORIDA, COUNTY OF QC-)'—,^, `Q`e61-tN-- ACKNOWLEDGED BEFORE ME THIS I-T!" DAY OF 20—fl— BY WHO IS ROWN TO ME OR HAS PRODUCED SIGNATURE OF NOTARY TYPE OR PRINT NAME OF NOTARY COMMISSION NUMBERIV!- NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MA FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCIN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Revised 4/26/2010 ENTIFICATION VIOLA INGRAHW �* MY COMMISSION # DD 884487 EXPIRES; April 27, 2013 bonded Th�: eudgef NotarySeNicea f RESULT IN YOUR PAYING TWICE 1, CONSULT YOUR LENDER OR CQ€.�NTY Re: Permit # Il 1 L— I)Z3 Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34992 772-462-2165 or 772-462-2172 Fax: 772-462-6443 ROOF INSPECTION AFFIDAVIT c�.�L�,� , licensed as a(n)Contractor*/Engineer/Architect (Please print name & circle license type) *FS468 Building Inspector *General, Building, Residential or Roofing Contractor or any individual certified under 468 FS. to make such an inspection. On or about JU(Ie 2i , 2 bl l , I did personally inspect the roof deck nailing (Date) work at: 92— Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S.) ,, d' Z ;), -, & j Signature and Seal STATE OF FLQRIDA COUNTY OF C AaQ C\-' CGS 057-7 5 3 License # Sworn to and subscribed before me this day of jUn e— 20 i, by Who ' perso own to me or who has produced as iden Notary Public, State of NotaFlorida Signature of ry: Commission Number: En 01/113/2011 .; - ,, "' f * * MY COMMISSION 9 DID 884� °` ,n-NED EXPIRES: ApM2T,2Bi3 ��°jgo"'es~ ftWed Ti uBUdget Not3rr5ekea JUN 2 2 2011 1-lu lic Works county, FL z'd 0692666199 piioS 411ng d'66:21 11 zz UDC I L_..,-..- i SAND" E. P U E RTA AR 95385 LICENSED FLORIDA ARCHITECT 6476 KIRSTEN WAY, LAKE WORTH, FL 33467 561- 248-5498 cell FILE C 561- 712-8895 fax Enhanced nailing calculations Address of job: ' 614 gamie Lane, Port St. Lucie, Fl 16' x 25' low slope roof. Total height 8'-4" Modified built up, roof NOA 09-0820,11 Tamko Modified Pitumen , P allow- -5Z, psf Overwood deck ; base sheet fa5�eninq 9 O.C. lap & 9 o.c. fwo rows FPC 2001/ Asa 7-0.5 - 140mph N , > 15' : exposure C Importance factor- 1.0 angle > 0 < I degree Cl- ( .00256) C Kz) ( Kzt) C Kd) C V) ( 1) - 29.9 psf velocitu pressure enhanced' Nail Inq' shall 6e a5 follows; foof Zone 12e51gn Wind Max. fastener 5pacinq Base sheet pressure �asteninq Field p-( -1.0-0.18) p< p allow 9" O.C. I,ap area I a- -42.7 psf s- 9" 9" o.c. two rows 3' edge p-C-1'.8-0'18)'.. 6" o c, I,ap area 2 a--11 '.6 psf s - C 52,5/ 71,6) C 9") =6 6" 6'' o,c. two rows 3' x 3'-C -2,8-0,18) 4" o,c, I,ap corners q--1011 psf s-( 52,5/ 107.1) (9") -4 3'' 4" o.c. two rows area J/ M IA WDADF BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION - NOTICE OF ACCEPTANCE OA Tamko Building Products, Inc. P.O. Box 1404 Joplin, MO 64802 ML4MI--DARE COUNTY, FLORIDA MEMO -DARE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMIL FLORIDA 33130-1563 (305) 375-2901 FAX (305) 375 2908 SCOPE. This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has beenreviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below, The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (m areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufactinw will incur the expense of such testing and the AHI may immediately revake� modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami - Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: TAMKO Modified Bitumen Roof System Over Wood Decks LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, c and following statement; "Miami -Dade County Product Control Approved", unless otherwis , herein. MEMO RENEWAL of this NOA shall be considered aftera. renewal application has been filed and ere has been no change in the applicable building code negatively aifu cling the performance. of this TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOAigW endorsement of any product, for sales, advertising or any other purposes shall automatically tdfiiinaM this NOA. Failure to comply with any section of this NOA. shall be cause for termination and%novif of NOA. ADVERTISEMENT: The NOA number -preceded by the words Miami -Dade County, Fl 'da, d followed by the expiration date may be displayed in advertising literature. If any portion of is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or, its distributors and shall be available for inspection at the job site at the request of the Building This NOA revises NOA No. 07-01 l 1.03 and consists of pages I through 18. The submitted documentation was reviewed by Jorge L. Acebo. �/� a NOA No.: 074V730.03 Expiation Date: 05/23/12 Approval Date: 01/10/08 69 Page 1 of 18 t ROOFING SYSTEM APPROVAL Ca o : Roofing Sub -Category: SBS/APP, Modified Bitumen Deck Type: Wood Maximum Design Pressure -60 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Dimensions Suecification Awaplan 170 FR Roll weighs: 98 ASTM D 5147 lbs.; 33' 11 " x 39 ASTM D6164 3/an Typet Grade G Awaplan 170Tp Roll weight: 98 ASTM D 5147 lbs.; 33' 11'rx 39 ASTM D 6164 3/an Type I Grade G - Awaplan Heat Roll weight: 96 ASTM D 5147 WeldingTm lbs.; 25' 5" x 39 3/s" ASTM D 6164 Type Q Grade G Awaplan Premium Roll weight: 101 ASTM D 5147 FRTm lbs.; 33' l 1" x 39 ASTM D 6164 3/an Type II Grade G Awaplan PremiumTM Roll weight:101 ASTM D 5147 lbs.; 3Y 1 I" x ASTM D 6164 393/a" Type H Grade G Awaflex Roll weight: 76 lbs; ASTM D 5147 35.9' x 36" Awaflex FR Roll weight: 76 lbs; ASTM D 5147 35.9' x 36" r o Product Description A 180 gW polyester reinforced SBS modified bitumen membrane surfaced with granules and treated for additional fire resistance. Applied in hot asphalt or cold adhesive. A 180 gW polyester reinforced SBS modified bitumen membrane surFaced with granules. Applied in hot asphalt or cold adhesive. - A 250 gW polyester reinforced SBS modified bitumen membrane surfaced with granules. Applied by torch and also used as a walkway material. A 250 g/W polyester reinforced modified bitumen membrane surfaced with granules. Applied by hot asphalt and also used as a walkway material. A 250 g/mz polyester reinforced SBS modified bitumen membrane surfaced with granules. Applied in hot asphalt or cold adhesive, and also used as a walkway material. SBS modified cap sheet constructed with a 155gm/mz non- woven polyester mat saturated with asphalt, coated on both sides with SBS rubber modified asphalt and surfaced with ceramic granules for UV protection. SBS FR modified cap sheet constructed with a 155gm/m2 non- woven polyester mat saturated with asphalt, coated on both sides with SBS rubber modified asphalt, FR tr+eated, and surfaced with ceramic grannies for UV protection. NOA No.: 07-0730.03 Expiration Date: 05/23/12 Approval Date: 01/10/08 Page 2 of 18 Test Product Product Dimensions Specification Description Awaplan Versa- Roll weight 100 ASTM D 5147 A 180 gW polyester reinforced SBS Smooth lbs. 33' 11" x MR/=" ASTM D 6164 modified bitumen membrane. Applied in Type I hot asphalt, by torch, or mechanically Grade S Fastened, as a base ply in 2 ply modified systems. Awaplan Versa -Flex Roll weight 76 lbs; ASTM D 5147 A 170 g/mz nonwoven polyester reinforced 33' 11" x 39-3/8" ASTM D 6164 SBS modified bitumen membrane. Type I Applied in hot asphalt, as a base ply in 2 Grade S ply modified systems. Base N-Ply® Roll weight 72 ASTM D 4601 Asphalt impregnated and coated glass fiber lbs.; 97'-6" x 30s" Type U base sheet for use in conventional and modified bitumen built-up roofing_ Glass-BaseTm Roll weight 72 ASTM D 4601 Asphalt impregnated and coated glass fiber lbs.; 97' 6" x 30s" Type 11 base sheet for use in conventional and modified bitumen built-up roofing. Tam-CapTM Roll weight 83 ASTM D 3909 Asphalt impregnated and coated felt Ibs.; 32' l 1" x' surfaced with mineral granules used as the 393/s" top ply in conventional built-up, roof membranes. Tam -Glass PremiumTM Roll weight: 53 ASTM D 2178 Asphalt impregnated glass felt for use in lbs.;161' 9" x Type Vl conventional and modified bitumen built 393/s" up roofing - Tam -Ply IVTM Roll weight 44 ASTM D 2179 Asphalt impregnated glass felt for use in lbs.; 161' 9" x Type IV conventional and modified bitumen built- 393/a' up roofing. Type 43 Base Sheet Roll weight 85 ASTM D 2626 An organic felt reinforced asphalt base lbs.; 72' x 36" sheet. Applied in hot asphalt or mechanically fastened Vapor-ChanTM Roll weight 86 ASTM D 4897 Heavy duty fiber glass base sheet lbs.; 32' 11" x impregnated and coated on both sides with 393/a" asphalt with or without a fine mineral stabilizer. Surfaced on the bottom side with coarse mineral granules embedded in hot asphaltic coating. Versa -Base FR=M Roll weight 60 ASTM D 5147 Asphalt impregnated and coated glass fiber lbs.; 487 2" x 301sa base sheet for use in conventional and modified bitumen built-up roofing. Versa-BaseTm Roll weight 94 ASTM D 5147 Asphalt impregnated and coated glass fiber lbs.; 48' 2" x 393/a" ASTM D 6163 base sheet for use in conventional and Type 1, Grade G modified bitumen built-up roofing. Versa -Cap FRTM Roll weight 87 ASTM D 5147 A fiberglass reinforced, mineral surfaced, lbs.; 33' x 39%" SBS modified bitumen top membrane. Tam Pro 846 Fibered 5 gallon ASTM D 1227, Protective coating. Emulsion Coating type Il Tam -Pro 813 Quick 5 gallon ASTM D 41 Asphalt based primer Dry Primer AIMk a NOA No.: 07-0730.03 Expiration Date: OM 23/12 Approval Date: 01/10/08 Page 3 of 13 Product Tam -Pro 842 Fine Rated Fiber+ed Aluminum Roof oating Test - Product Dimensions Saecification Description 5 gallons ASTM D2824, Flame retardant protective coating type III APPROVED INSULATIONS: Product Name Pyrox, White Line ACFoam Composite ACFoam 11 ConPearl EnergyGuard Perlite EnergyGuard Fiberboard Dens Deck TABLE 2 Product Description Isocyanurate Insulation. Isocyanurate Insulation with perlite facer. Isocyanurate Insulation. Expanded perlite mineral fiber Insulation. Expanded mineral fiber Insulation. Wood fiber board Insulation. Silicon treated gypsum board. Sturdi-Top Wood fiber insulation board. Wood Fiberboard Regular wood fiber insulation. High Density Wood Fiberboard High Density Wood Fiber insulation board. Perlite Insulation Board Perlite Insulation. Armor Board Regular Fiberboard' Wood fiber board Insulation. Hubert Fiberboard Wood fiber board Insulation. ENRGY 2, ENERGY 3, PSI 25 Isocyanurate Insulation. Retro Fit Board, DuraBoard A high -density perlite roof insulation. Fesco Board Rigid perlite roof insulation board. Kop-R Wood Fiber Wood fiber board Insulation. Structodeck, Structodek FS High Density Wood Fiber insulation board. H-Shield Isocyanurate Insulation. H-Shield WF Wood fiber/ Isocyanurate Composite Insulation. Manufacturer (With Current NOA) Apache Products Co. Atlas Roofing Corp. Atlas Roofing Corp. Conglas GAF Mat'l. Corp. GAF Mat'l. Corp. G-P Products G-P Products Generic Generic Generic Honeywell Int'l. Inc. Huebert Fiberboard, Inc. Johns Manville Johns Manville Johns Manville Koppers Industries, Inc. Masonite Hunter Panels, LLC Hunter Panels, LLC NOA No.: 074 730.03 Expiration Date: 65/23/12 Approval Date: 01/10/08 Page 4 of 18 APPROVED FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions nth Current NOA) L Dekfast Fasteners #12, Insulation fastener for wood, SFS Intec Inc_ #14 & #15 steel and concrete decks 2. Dekf ist Hex Plate Galvalume hex stress plate. 2 7/8" x SFS Intec, Inc. 3 1/4" 3. #12 Roofgrip Fasteners Insulation fastener for wood ITW Buildex Corp. and steel. 4. Metal Plate Galvalume stress plate. 3" round Tf W-Buildex Corp. 3» square 5. Olympic Fastener #12 - Insulation fastener Olympic Mfg Group, Inc.. & #14 6. Olympic G-2 Galvalume AZ55 steel plate 3.5" round Olympic Mfg Group, Inc. 7. Olympic Standard Galvalume AZ50 steel plate 3" round Olympic Mfg Group, Inc. 8. Insul-Fixx Fastener Insulation fastener for steel SFS Intec, Inc. and wood decks 9. Insul-Fixx S Plate Galvalume AZ50 steel plate 3" round SFS Intec, Inc. 10. Tru-Fast Insulation fastener for steel The Try -Fast Corp. and wood decks 11. Tru-Fast Plates Galvalume AZ55 steel plate 3" round The Tru-Fast Corp. EviwNcE SuBMrmw Test Ageney/Identifier Name Date Factory Mutual Research Corp. Comparative Rupture Testing J.I.4DOA7.AM 10.21.98 Class l Fire J.I.OZ4A3.AM 08.27.97 Class 1 Fire; l 90 Windstorm J.L 1D4A7.AM 10.20.97 Class 1 Fire; 1 90 Windstorm J.L 3B5A9.AM 0827.98 Exterior Research & Design, LLC Wind Uplift Testing 4444.06.98-1 06.15.98 Wind Uplift Testing 4449.08.99-1 08.03.99 Trinty I ER.D TAS 117(B)/ ASTM D6862 C8500SC.11.07 11.30.07 AlQkk 6 ' NOA Na. 07-0730.03 Imar -IN Expiration Date: 05/23n2 Approval Date: 01/10/08 pap 5ofis APPROVED ASSEMLIES: "Deck Type 1I: Wood, Insulated Deck Description: Minimum 15/32" or greater plywood or wood plank Plywood shall be attached to 2" x 4" wood supports spaced 24" o.c. using wood screws spaced G' o.c. at perimeters and intermediate supports. System Type A: Anchor sheet mechanically fastened, all layers of insulation adhered with approved asphalt. All General and System Limitations apply. Anchor Sheet: One ply of Tamko Glass -Base, Vapor -Chan or Base-N Ply fastened to the deck as described below: Fastening: (Option #I) Attach anchor sheet using I 1 ga. annular ring shank nails and 1 518" diameter tin caps spaced 9" o.c. in a 4" lap and 9" o.c. in two staggered rows in the center of the shy. (-525 psf, See General Lrndtation #7.) (Option #2) Attach anchor sheet using #12 or #14 Dekfast Fasteners with Hex Plates, SFS #12 or HD h odfixx S, or Burldex Accutrac Fasteners and 3" Square Plates spaced 12" o.c. in a 4" lap and 12" o.c. in two staggered rows in the center of the sheet. (-60 pSj See General Lines x #7.) One or more layers of any of the following insulations: Base Insulation Layer Insulation Fasteners Fastener ACFoam II (Table 3) Density/fe Minimum 12" thick N/A N/A UltraGard Gold Minimum 13" thick N/A N/A ENRGY-2, ENRGY 3, PSI-25, H-Shield Minimum 1.4" thick N/A N/A Top or Base Insulation Layer Insulation Fasteners Fastener {Table 3) Density/fe ConPerl, EnergyGuard Perlite, Fe_sco Board, Retro FM4 High Density Wood Fiberboard, Structodek FS Minimum %Z" thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in fall mopping of approved hot asphalt within the EVT range and at a rate of 20-40 0000 fe Please refer to Roofing Application Standard RAS 117 for insulation attachment Insulation listed as base layer only Shan be used only as base layers with a second layer of approved top layer insubtion installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with .the polyisocyarimmte side facing down. 0 NOA No.: 07-0730.03 Mar -W Expiration Date: 05123/12 ra Approval Date: 01/10/08 Page 6 of 18 Base Sheet: (Optional) One ply of Glass -Base, Base-N-Ply, Versa -Base, Versa -Smooth, Awaplan VersaFlex, or Vapor -Chan adhered to the substrate with a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Ply Sheet: One or more plies of Tam -Glass Premium, Tam -Ply 1V, Glass Base, Base-N-Ply, Awaplan VersaFlex, Awaplan Versa -smooth, or Versa -Base adhered with a full mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbs./sq. Membrane: Awaplan Premium, Awaplan Premium FR, Awaplan 170, Awaflex, Awaflex FR„ Awaplan 170 FR, Awaplan Versa -Smooth, Awaplan VersaFlex, or Versa -Cap FR adhered with a full mopping of approved asphalt applied at 400` F at the point of contact and at a rate of 20-40 lbs./sq.; or Awaplan Heat Welding or Versa -Smooth adhered by torch. Surfacing: Optional to mineral surfaced Membranes. Required for smooth surfaced membranes: 1. 4001b./sq. gravel or 300 lb./sq. slag in a flood coat of approved mopping asphalt at an application rate of 601b./sq.. 2. Tam -Pro FR Aluminum Coating applied at 1 %2 gal./sq., or Tam -Pro 846 Fibered Emulsion Coating at 3 gal./sq. Maximum Design Pressure: See Anchor Sheet Fastening Options above. © NOA No.: 07-0730.03 y Expiration Date: 05/23/12 Approval Date: 01/10/08 Page 7 of 18 Deck Type II: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank System Type B(1): Base layer of insulation mechanically fastened; optional top layer adhered with approved asphalt. All General and System Limitations apply. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/fe ACFoam II, White Line, H-Shield Minimum 1.2" thick 1, 3, 5 or 10 1:2 ft2 ACFoam II Minimum 1.4" thick 1, 3,5 or 10 1:4 ft2 ENRGY-2, ENRGY-3 Minimum 1.4" thick 1, 3, 5 or 10 1:2 ftZ U1traGard Gold Minimum 1.3" thick 1, 3,5 or 10 1:2 if ACFoam Composite, H-Shield WF Minimum 1.5" thick 1, 3,5 or 10 1:4 ft2 ConPerl, EnergyGuard Perlite, Fesco Board, Armor Board Regular, Esgard, Wood Fiberboard, EnergyGuard Fiberboard, Huebert Fiberboard, Kop-R Wood Fiber, Structodek Minimum 1" thick 1, 3,5 or 10 1.2 W Note: Base layer shall be mechanically attached with fasteners and density described. Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be increased maintaining the same fastener density (See Roofing Application. Standard RAS 117 for fastening details). Top Insulation Layer (Optional) ConPerl; EnergyGuard Perlite, Fesco Board, Retrofit Minimum %2" thick ACFoam Composite, H-Shield Minimum 1.5" thick Insulation Fasteners Fastener (Table 3) Density/fe N/A N/A N/A N/A Note: Apply optional top layer of insulation shall be adhered with approved hot asphalt within the, EVT range and at a rate of 20-40 lbs/100 fe. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulations listed as the base layer shall only be used as the base layer with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side face down. Base Sheet: (Optional) One ply of Glass -Base, Base-N-Ply, Versa -Base, Versa -Smooth, Awaplan VersaFlex, or Vapor -Chan adhered to the substrate with a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Y NOA No.: 07-0730.03 Expiration Date: 05/23/12 Approval Date: 01/10/08 Page 0 of 18 Ply Sheet: One or more plies of Tam -Glass Premium, Tam -Ply IV, Glass Base, Base-N-Ply, Awaplan VersaFlex, Awaplan Versa -Smooth, or Versa -Base adhered with a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Membrane: Awaplan Premium, Awaplan Premium FR, Awaplan 170, Awaflex, Awaflex FR„ Awaplan 170 FR, Awaplan Versa -Smooth, Awaplan VersaFlex, or Versa -Cap FR adhered with a full mopping of approved asphalt applied at 400` F at the point of contact and at a rate of 20-40 lbs./sq.; or-Awaplan Heat Welding or Versa -Smooth adhered by torch. Surfacing: Optional to mineral surfaced Membranes. Required for smooth surfaced membranes: 1. 400. lb./sq. gravel or 300 lb./sq. slag in a flood coat of approved mopping asphalt at an application rate of 60 lb./sq.. 2. Tam -Pro FR Aluminum Coating applied at 1'/2 gal./sq. or Tam -Pro 846 Fibered Emulsion Coating at 3 gal./sq. Maximum Design Pressure: -45 psf; (See General Limitation #9.) C.NOA No,: 07-0730.03 Expiration Date: 05/23/12 Approval Date: 01/10/08 Page 9 of 18 Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank. Plywood shall be attached to 2" x 4" wood supports spaced 24" o.c. using wood screws spaced 6" o.c. at perimeters and intermediate supports. System Type B(2): Base layer of insulation mechanically fastened; top layer adhered with approved asphalt. All General and System Limitations apply. Base Insulation Layer Insulation Fasteners Fastener ACFoam lI, ENRGY-2, ENRGY-3, PSI-25, H-Shield (Table 3) Density/ftz Minimum 1.5" thick 5 or 8 1.1.33 ft2 Note: Base layer shall be mechanically attached with fasteners and density described. Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be increased maintaining the same fastener density (See Roofing Application Standard RAS 117 for fastening details). Top Insulation Layer (Optional) Insulation Fasteners Fastener High Density Wood Fiberboard (Table 3) Density/fe Minimum %" thick N/A N/A Note: Apply optional top layer of insulation shall be adhered with approved hot asphalt within the EVT range and at a rate of 20-40 lbs/100 fe. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulations listed as the base layer shall only be used as the base layer with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with. the polyisocyanurate side face down. Base Sheet: (Optional) One ply of Glass -Base, Base-N-Ply, Versa -Base, Versa -Smooth, Awaplan VersaFlex, or Vapor -Chan adhered to the substrate with a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Ply Sheet: One or more plies of Tarn -Glass Premium, Tam -Ply IV, Glass Base, Base-N-Ply, Awaplan VersaFlex, Awaplan Versa -Smooth, or Versa -Base adhered with a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Membrane: Awaplan Premium, Awaplan Premium FR, Awaplan 170, Awaflex, Awaflex FR„ Awaplan 170 FR, Awaplan Versa -Smooth, Awaplan VersaFlex, or Versa -Cap FR adhered with a full mopping of approved asphalt applied at 400' F at the point of contact and at a rate of 20-40 lbs./sq.; or Awaplan Heat Welding or Versa -Smooth adhered by torch. © NOA No.: 07-0730.03 Expiration Date: 05/23/12 Approval Date: 01/10/08 Page 10 of 18 i Surfacing: Optional to mineral surfaced Membranes. Required for smooth surfaced membranes: 1. 400 lb./sq. gavel or 300 lb./sq. slag in a flood coat of approved mopping asphalt at an application rate of 601b./sq.. 2. Tam -Pro FR Aluminum Coating applied at l'/2 gal./sq., or Tam -Pro 846 Fibered Emulsion Coating at 3 gal./sq. Maximum Design Pressure: -60 psf (See General Limitation #7.) NOA No.: 07-0730.03 Expiration Date: O5/23/12 Approval Date: O1/10/08 Page 11 of 18 Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank System Type C: All layers of insulation simultaneously mechanically fastened. All General and System Limitations apply. One or more layers of any of the following insulations: Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ftz ACFoam II, White Line, H-Shield Minimum 1.2" thick N/A N/A UltraGard Gold Minimum 1.3" thick N/A N/A ENRGY-2, ENRGY-3, PSI-25 Minimum 1.4" thick N/A N/A Note: All layers shall be simultaneously attached; see top layer below for fasteners and density. Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/fe ConPerl, EnergyGuard Perlite, Fesco Board, Armor Board Regular, Esgard, Fiberboard, EnergyGuard Fiberboard, Huebert Fiberboard, Kop-R Wood Fiber Minimum I" thick 1, 3,5 or 10 1:2 ft, Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: (Optional) One ply of Glass -Base, Base-N-Ply, Versa -Base, Versa -Smooth, Awaplan VersaFlex, or Vapor -Chan adhered to the substrate with a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Ply Sheet: One or more plies of Tam -Glass Premium, Tam -Ply IV, GIass Base, Base-N-Ply, Awaplan VersaFlex, Awaplan Versa -Smooth, or Versa -Base adhered with a full mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbs./sq. Membrane: Awaplan Premium, Awaplan Premium FR, Awaplan 170, Awaflex, Awaflex FR„ Awaplan 170 FR, Awaplan Versa -Smooth, Awaplan VersaFlex, or Versa -Cap FR adhered with a full mopping of approved asphalt applied at 400' F at the point of contact and at a rate of 2040 lbs./sq.; or Awaplan Heat Welding or Versa -Smooth adhered by torch. NOA No.: 07-0730.03 W.A31 Expiration Date: 05/23/12 Approval Date: 01/10/08 Page 12 of 18 Surfacing: Optional to mineral surfaced Membranes. Required for smooth surfaced membranes: 1. 4001b./sq. gravel or 300 lb./sq. slag in a flood coat of approved mopping asphalt at an application rate of 60 lb./sq.. 2. Tam -Pro FR Aluminum Coating applied at I %2 gal./sq., or Tam -Pro 846 Fibered Emulsion Coating at 3 gal./sq. Maximum Design Pressure: -45 psf;(See General Limitation #9.) 0 NOA No.: 07-0730.03 Expiration Date: 05/23/12 Approval Date: 01/10/08 Page 13of18 Deck Type 11: Wood, Insulated Deck Description: Minimum 15/32" or greater plywood or wood plank. Plywood shall be attached to 2" x 4" wood supports spaced 24" o.c. using wood screws spaced 6" o.c. at perimeters and intermediate supports. System Type D: Base sheet attached over insulation. All General and System Limitations apply. One or more layers of any of the following insulations adhered to deck: Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft' ACFoam II, White Line, H-Shield Minimum 1.2" thick N/A N/A U1traGard Gold Minimum 1.3" thick N/A N/A ENRGY-2, ENRGY-3, PSI-25 Minimum 1.4", thick N/A N/A ConPerl, EnergyGuard Perlite, Fesco Board Minimum %.... thick N/A N/A Armor Board Regular, Esgard, Fiberboard, EnergyGuard Fiberboard, Huebert Fiberboard, Kop- R Wood Fiber, Structodek Minimum %Z"" thick N/A N/A Note: Top layer shall have preliminary attachment, prior to the installation of the base/anchor sheet, at a minimum application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft., and four fasteners for any insulation board having no dimension greater than 8 ft. All layers of insulation and base sheet shall be simultaneously fastened. See base/anchor sheet below for fasteners and density. Base Sheet: One ply of Tamko Glass -Base, Versa -Base, Awaflex, Versa -Flex, Vapor -Chan or Base-N Ply fastened to the deck as described below: Fastening: Attach anchor sheet using#12 or #14 Dekfast Fasteners with Hex Plates or SFS #12 HD Insulfixx S or Buildex Accutrac Fasteners and 3" Square Plates spaced 12" o.c. in a 4" lap and 12" o.c. in two staggered rows in the center of the sheet. Ply Sheet: (Optional) One or more plies of Tam -Glass Premium, Tam -Ply IV, Glass Base, Base-N-Ply, Awaplan Versa -Smooth, Awaplan VersaFlex, or Versa -Base adhered with a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs,/sq. 0 NOA No.: 07-0730.03 Expiration Date: 05/23/12 Approval Date: 01/10/08 Page 14 of 18 ram, Membrane: Awaplan Premium, Awaplan Premium FR, Awaplan 170, Awaflex, Awaflex FR„ Awaplan 170 FR, Awaplan Versa -Smooth, Awaplan VersaFlex, or Versa -Cap FR adhered with a full mopping of approved asphalt applied at 400' F at the point of contact and at a rate of 20-401bs./sq.; or Awaplan Heat Welding or Versa -Smooth adhered by torch. Surfacing: Optional to mineral surfaced Membranes. Required for smooth surfaced membranes: 1. 4001b./sq. gravel or 300 lb./sq. slag in a flood coat of approved mopping asphalt at an application rate of 60 lb./sq. 2. Tam -Pro FR Aluminum Coating applied at 1 %a gal./sq., or Tam -Pro 846 Fibered Emulsion Coating at 3 gal./sq. Maximum Design Pressure: -60 psf, (See General Limitation #7.) NOA No.: 07-0730.03 { Expiration Date: 05/23/12 Approval Date: 01/10/08 Page 15 of 18 Deck Type 1 Deck Description: Wood, Non -insulated Minimum 15/3Z" or greater plywood or wood plank. Plywood shall be•a...._ 2" x 4" wood supports spaced 24" o.c. using wood screws spaced 6" o.c. perimeters and intermediate supports. System Type E(1): Base sheet mechanically fastened. All General and System Limitations apply. Anchor Sheet: One ply of Tamko Glass -Base, Vapor -Chan, Versa -Flex, Versa -Base, Versa - Smooth or Base-N-Ply fastened to the deck as described below: Fastening: (Option #1) Attach anchor sheet using 11 ga. annular ring shank nails and 1-5/8" diameter tin caps spaced 9" o.c. in a 4" lap and 9" o.c. in two staggered rows in the center of the sheet. (-52.5 psf, See General Limitation #7.) (Option #2) Attach anchor sheet using #12 or #14 Dekfast Fasteners with Hex Plates, SFS #12 or HD Insulfixx S, or Buildex Accutrac Fasteners and 3" Square Plates spaced 12" o.c. in a 4" lap and 12" o.c. in two staggered rows in the center of the sheet. (-60.0 psf, See General Limitation #7.) Ply Sheet: (Optional) One or more plies of Tam -Glass Premium, Tam -Ply IV, Glass Base, Base-N-Ply, Awaplan Versa -Smooth, Awaplan VersaFlex, or Versa -Base adhered with a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Membrane: Awaplan Premium, Awaplan Premium FR, Awaplan 170, Awaflex, Awaflex FR„ Awaplan 170 FR, Awaplan Versa -Smooth, Awaplan VersaFlex, or Versa -Cap FR adhered with a full mopping of approved asphalt applied at 400' F at the point of contact and at a rate of 20-401bs./sq.; or Awaplan Heat Welding or Versa -Smooth adhered by torch. Surfacing: Optional to mineral surfaced Membranes. Required for smooth surfaced membranes: 1. 4001b./sq. gravel or 300 lb./sq. slag in a flood coat of approved mopping asphalt at an application rate of 60 lb./sq.. 2. Tam Pro FR Aluminum Coating applied at l'/a gal./sq., or Tam -Pro 846 Fibered Emulsion Coating at 3 gal./sq. Maximum Design Pressure: See Base Sheet Fastening Options above NOA No.: 07-0730.03 Y Expiration Date: 05/23/12 Approval Date: 01/10/08 Page 16 of 18 Deck Type 1: Wood, Non -insulated Deck Description: Minimum 15/32" or greater plywood or wood plank. Plywood shall be attached to 2" x 4" wood supports spaced 24" o.c. using wood screws spaced 6" o.c. at perimeters and intermediate supports. System Type E(2): Base sheet mechanically fastened. All General and System Limitations apply. Anchor Sheet: One ply of Tamko Glass -Base, Vapor -Chan, Versa -Flex, Versa -Base, Versa - Smooth or Base-N-Ply fastened to the deck as described below: Fastening: (Option #I) One ply of Red Rosin sheet loose laid over deck. Followed by anchor sheet attached using Simplex Mega Cap Nails spaced 9" o.c. in a 4" lap and 9" o.c. in two staggered rows in the center of the sheet. (^45 psf, See General Limitation #7.) (Option #2) Attach anchor sheet using Simplex Mega Cap Nails spaced 9" o.c. in a 4" lap and 9" o.c. in two staggered rows in the center of the sheet. (-60 psf, See General Limitation #7.) Ply Sheet: (Optional) One or more plies of Tam -Glass Premium, Tam -Ply IV, Glass Base, Base-N-Ply, Awaplan Versa -Smooth, Awaplan VersaFlex, or Versa -Base adhered with a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Membrane: Awaplan Premium, Awaplan Premium FR, Awaplan 170, Awaflex, Awaflex FR„ Awaplan 170 FR, Awaplan Versa -Smooth, Awaplan VersaFlex, or Versa -Cap FR adhered with a full mopping of approved asphalt applied at 400' F at the point of contact and at a rate of 20-40 lbs./sq.; or Awaplan Heat Welding or Versa -Smooth adhered by torch. Surfacing: Optional to mineral surfaced Membranes. Required for smooth surfaced membranes: 1. 4001b./sq. gravel or 300 lb./sq. slag in a flood coat of approved mopping asphalt at an application rate of 60 lb./sq.. 2. Tam -Pro FR Aluminum Coating applied at 11/2 gal./sq. or Tam -Pro 846 Fibered Emulsion Coating at 3 gal./sq. Maximum Design Pressure: See Base Sheet Fastening Options above 0 NOA No.: 07-0730.03 JIL Expiration Date: 05/23/12 Approval Date: 01/10/08 Page 17 of 18 WOOD DECK SYSTEM LIMITATIONS: 1. A slip -sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet: GENERAL LIMITATIONS: 1. 2. 3. 4. 5. 6. 7. 8. J 10. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F) value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field- tested, are below 275 lbf. insulation attachment shall not be acceptable. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform with Roofing Application Standard RAS 111 and applicable wind load requirements. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and comers). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B-72 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 07-0730.03 Expiration Date: 05/23/12 Approval Date: 01/10/08 Page 18 of 18