Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSDate: /7-�' /_ Fee Due: Recei t# L rermit # Electrical ❑ Shed St. Lucie County Building & Zoning 2300 Virginia Avenue Ft. Pierce, FL 34982-5652 Tel. •462-1553 SPECIALTY PERMIT APPLICATION ❑ Plumbing ❑ HVAC ❑ Fence ❑ Demolition ❑ Gas ❑ Siding S aNNE10 St. Y Lucie count Y See page 2 for instructions and additional paperwork required for specialty permits 1. Location/Site Address: 3001 I ylc�u Sfr,'� 2 AV 2. Parcel ID Number: 1 qZ 9 50/ 000q 000 ( Office Use Only Section I Township Range I Ma Pa a I Zoning Land se I lni ials S C 111.)?1Y 3. Description of Project or Work Activity: rt v, I) H S er►►1; + Lv S pofled for tn. f l d�t`I+It D'F a►emerifor dhz 01K4 W"V1`hA)) l'&rh WcIf C� U b9 Qve xCf�11 1�oV' Sef�1�1 � I � P dC l ud' deKe�'d��i, �%��'�h ►SfS � ���tevr�orfest ��ftc�►r� Ll 4. Owners Information Name: BriCas c10 5' rdliw Corp Address: 9 Box 70Z City: f!U/d tl ke e State: W -1- 5. Contractors Information FL Reg/Cert #: F R - 6 015363 County Cert#: Z 0 9 9 Business Name: 6h Zip: 5-3zOf_o702 Phone: WC43*09 Phone Z -g 97 Fax g2-9a!K$7( 6. Value of Construction: $ Z,000 -I OWNER'S AFFIDAVIT: 1 certify that all of the information contained in this application is correct and that all work will be done in compliance with all applicable laws regulating construction and zoning. .Pd 0 fl h f 7/ A�zsk PRINT QUALIFIERS/OWNERS NAME SIGNATURE OF QUALIFIER/OWNER ORIDA, C TY OF Co[� ACKNOWLEDGED BEFORE ME THIS DAY OF LBY Q n / le WHO IS PERSONALLY KNOWN TO ME OR WHO HAS PRODUCED t NTIFICATION. � IG1 1-�()1(Un -e (seal) f010n R PRINT NAME OF NOTARY NATURE OF NOTARY — TITLE: NOTARY PUBLIC St, Lucie County Specialty Permit Application rev. 8/25/05 dmg COMMISSION NUMBER a"1's DEmiLoNEMYCOM2587 EXPIRE013 Bonded Thru ery NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. EXEMPT: A/C -HEAT REPLACEMENT WITH CONTRACT UNDER $5,000. INSTRUCTIONS Please complete all information in the space provided. All information must be printed (use black or blue ink only) or typed. This permit application is to be used only for those activities that are not otherwise included under a primary building permit. This application may not be used for any activity that includes structural alteration. The information to be provided with this application includes: 1. Location/Site Address 2. Parcel ID Number 3. Description of Project or Work Activity 4. Owner Information 5. Contractor Information 6. Value of Construction Indicate the street address or general location of the property where the building activity is taking place. Indicate the tax identification number of the property where the building activity is taking place. Fully describe the activity to take place. Indicate the name and address of the owner of the property on which activity is taking place. Indicate the State of Florida registration number (if applicable), St. Lucie County contractor license number and the name of the business doing the work. Indicate the total value of the work to take place. Total cost of construction includes all current retail material and labor costs associated with the building/construction activity. Construction value is used to determine the permit fee. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction. ❑ Gas Attach 2 piping schematics with tank size, location, and BTU of each appliance ❑ Shed: Attach 2 plot plans, 2 copies of DCA letter and plans, 2 anchor specifications ❑ Fence Attach 2 plot plans showing location of fence height of fence and type of fence ❑ Siding Attach 2 copies of manufactures specifications ❑ HVAC Attach 2 residential energy studies, 2 manual J calculations. 2 sets of duct layouts for new system or full replacement This application can be submitted to St. Lucie County Building and Zoning, 2300 Virginia Avenue, Fort Pierce, FL 34982. All permit applications must be filled out completely before submission. No applications will be accepted for processing after 4:30 P.M. For assistance in completing this application, please call (772) 462-1553, during regular office hours (8:00 AM - 5:00 PM), Monday through Friday. NOTE: Emergency electric service change out inspections will not be performed after 3: 00 PM without special arrangements and additional fee paid. Upon issuance of this permit, required inspections can be scheduled by calling (772) 462-1261. St. Lucie County Specialty Permit Application rev. 8/25/05 dmg Briggs & Stratton Test facility 3,001 Industrial Avenue Two Fort Pierce, FL. 34946-8623 FPUA PVI.eter 12-01240 3ph 4a01250 120124-1 fused disc 3PH AV Eel 2.5" 3 310 16 TH HN cu. Electrical Additions for Generator Testing Panel III 2.6t1 200A 3 Phase 4310 ABCN .1-6 2 611 � 3 3f0 1-6 Panel THHN cu 200A -____-- 1phase ACN This f�er wiii be _ 3 310 A -a. 200A I I 200A N E 200A II 1-6 HN cu. ATS 1 2.6., tam NEW WORK = Existing ST. LUCIE COL NTY BLT1 Ly 1. O DItiZSION REVIEWED FOR COMP REVIEW BY DATE PLANS -DP XMIT fifGST BE KEPT On JOB OR NO i YSMT1110-N WILL BE NUDE. Prime 30145 KW Standby Generator To monitor Generator Current N CT E e200A THHN cu. ATS2 To be instalte-d in the FUTURE Test Standby Generator 2OKW OI v r wd y =�- t i" ,�---- ILI *jl ✓ (off lei, Prod toHKe e"d [ I Generator Location Before installing the generator, consult with the homeowner and convey the following guidelines, which may affect the desired installation location. Install generator outdoors in an area which will not accumulate deadly exhaust gas. DO NOT install generator where exhaust gas could accumulate and enter inside or be drawn into a potentially occupied building. Ensure exhaust gas is kept away from windows, doors, ventilation intakes or other openings that can allow exhaust gas to collect in a confined area. Prevailing winds and air currents should be taken into consideration when positioning generator. A WARNING Running engine gives off carbon monoxide, an odorless, colorless, poison gas. Breathing carbon monoxide could result in death, serious injury, headache, fatigue, dizziness, vomiting, confusion, seizures, nausea or fainting. • Operate this product ONLY outdoors. • Install a battery operated carbon monoxide alarm near the bedrooms. • Keep exhaust gas from entering a confined area through windows, doors, ventilation intakes, or other openings. A WARNING Exhaust heat/gases could ignite combustibles or structures resulting in death, serious injury and/or property damage. • DO NOT install the generator closer than 5 feet (1.5m) from any combustibles or structures with combustible walls having a fire resistance rating of less than 1 hour. General Location Guidelines • Install the unit outdoors ONLY. • Place the unit on a prepared concrete slab that is flat, level, and has provisions for water drainage. • Install the unit in a location where sump pump discharge, rain gutter down spouts, roof run-off, landscape irrigation, or water sprinklers will not flood the unit or spray the enclosure and enter any air inlet or outlet openings. • Install the unit where it will not affect or obstruct any services (including covered, concealed and underground), such as telephone, electric, fuel, irrigation, air conditioning, and so forth. • Install the unit where air inlet and outlet openings will not become obstructed by leaves, grass, snow, etc. If prevailing winds will cause blowing or drifting, you may need to construct a windbreak to protect the unit. • Install the generator as close as possible to the transfer switch and fuel supply to reduce the length of wiring, conduit, and piping. Laws or local codes may regulate the distance to the fuel supply. The minimum (MIN) clearances from aerial view of generator (B) to combustible (D), and non-combustible (A) materials is shown below. • These distances are provided to give generator location guidance relative ONLY to combustibles, generator cooling, and maintenance. • The minimum distances in the figure are as shown. All four sides of the generator cannot be enclosed or restricted, even if the minimum distances are maintained. DO NOT connect (A) and/or (0) to (E). • A roof cannot be used. • Exhaust (C) must not be allowed to accumulate. ---------------------------- ----------- ; 5' (1.5m) 2' I I (.6m) I 3' 2' f (.9m) (.6m) I � I i �- 5' (1.5m) 5' (1.5m) IF C I- L O 5' (1.5m) ----------------------------------------- - A Non -Combustible material with Fire Resistant ti of 1 hour or greater 8 Home Standby Generator C Engine Exhaust D Combustible Material or Structure with a Fire Resistance Rating of less than 1 hour E Any structure or material. DO NOT connect (A) and/or (D) to (E) BRIGGSandSTRATTON.COM Concrete Slab At the appropriate location, construct a concrete slab: • 28 day compression strength of 3000 psi (200 MPa) • Minimum 5" (13cm) thick • Minimum 6" 05cm) wider than enclosure on all sides (shown as D in figure) • Strengthen slab with No. 6 reinforcing bars (on 12" (30.5cm) centers) or 8 ga. steel wire fabric (6" (15cm) centers). Avoid placing reinforcement in entrance stub up area (B). Attach unit to slab at four corner locations (A) with minimum 5/16"(8mm) diameter masonry anchor bolts long enough to secure the unit. The fuel inlet location (C) and the concrete slab (0) are shown for reference. 34-114" 7-3/4"� 1044cm 235cm r_5-1/4" 160cm i 8-1/4" 250cm 9-3/8" 286cm 80-1/4" 43-1/4" 1318cm v 2446cm J A Holes located in base to anchor to pad B Stub up Area C Fuel Inlet D Concrete slab Electrical and Fuel Inlet Locations A through -slab power cable stub -up is preferred see (B). If stub-up's are not used, (F) indicates the recommended location for punching holes for attaching power conduit. The 1 inch N.P.T. fuel inlet connector (C) is shown for reference. Lifting the Generator The generator weighs more than 1,700 pounds (773 kg). Proper tools, equipment and qualified personnel should be used in all phases of handling and moving the generator. A WARNING Hazardous Voltage - Contact with power * lines could cause electric shock or burns, I'm resulting in death or serious injury. va In Lifting Hazard / Heavy Object - Could result in serious injury. • If lifting or hoisting equipment is used, DO NOT contact any power lines. • DO NOT lift or move generator without assistance. • Use lifting pipes as described in Lifting the Generator. • DO NOT lift unit by roof as damage to generator will occur. Remove circuit breaker box bottom plate prior to positioning generator. Two 60" (1.5m) lengths of 2" Schedule 40 pipe Al supplied by the installer, are required to lift the generator onto cement pad. Insert pipes through the lifting holes (H) located near the unit's base. Use a spreader bar to ensure that the chains, straps or cables DO NOT touch the generator's roof. Retouch any chipped paint with supplied touch-up paint. 9 Access Ports The generator is equipped with an enclosure that has several access doors, as shown above. The doors are named for a significant component located behind them, as follows: A. - Fuel Inlet port (shown for reference) B. - Control Panel door (may be two doors) C. - Exhaust opening (shown for reference) D. - Coolant/Oil Fill door E. - Battery door F. - Muffler door A WARNING Contact with muffler area could cause burns resulting in serious injury. W4 • DO NOT touch hot parts and AVOID hot exhaust gases. Allow equipment to cool before touching. The Coolant Fill, Battery and Control Panel doors must be installed whenever the unit is running to assure proper cooling, reduce noise and for added safety. The enclosure also includes muffler and radiator access panels, used only for cleaning those components. Those panels should remain closed at all other times. Each generator is shipped with a set of identical keys. These keys fit the locks that secure the access ports. To open access door: 1. Insert key into lock of access door handle and turn key one quarter turn counterclockwise. 2. Grasp door's handle and turn one quarter turn counterclockwise to open. Remove key. 3. Coolant Fill door is unlocked in the same manner. It can be used for adding coolant or oil. To close access door: 0 1. Close door and turn door's handle one quarter turn clockwise. 2. Insert key into lock of door handle and turn key o quarter turn clockwise. Remove key.Am 'ftk q y The Gaseous Fuel System v The information below is provided to assist gaseous f V1 ; system technicians in planning installations. In no ways .: should this information be interpreted to conflict with applicable fuel gas codes. Consult with your local fuelt.,� supplier or Fire Marshall if questions or problems arise-. A WARNING Propane and Natural Gas are extremely �4I flammable and explosive, which could cause burns, fire or explosion resulting in death, serious injury and/or property damage. • LP gas is heavier than air and will settle in low areas. • Natural gas is lighter than air and will collect in -high areas. • The slightest spark could ignite these fuels and cause an explosion. • DO NOT light a cigarette or smoke. TO THE INSTALLER: Consult with the generator owner(s) and convey any technical considerations that might affect their installation plans before applying these general guidelines. The following general rules apply to gaseous fuel system piping: • The piping should be of a material that conforms to federal and local codes, rigidly mounted and protected against vibration. • Piping should be protected from physical damage where it passes through flower beds, shrub beds, and other cultivated areas where damage could occur. 10 BRIGGSandSTRATTON.COM Property Appraiser - St.Lucie Coiinty, FL Page 1 of 1 PROPERTY RECORD CARD Briggs and Stratton Corp Record: 1 of 1 <<Prev Next» Spec.Assmnt Taxes Exemptions Permits Home Print Property Identification ,`\UCIE CO Site Address: 3001 INDUSTRIAL 2 AV ParcellD: 1429-501-0004-000-6 �� G� Sec/Town/Range: 29 :34S :40E Account #: 10124 �� < Map ID: 14/29S Land Use: LGHT MNFCT Zoning: IL City/Cnty: St Lucie County �! Ownership and Mailing Legal Description Owner: Briggs and Stratton Corp AIRPORT INDUSTRIAL PARK -UNIT ONE- BLK 1 LOT 4 (OR 441- Address: PO Box 702 1927) Milwaukee WI 53201-0702 Sales Information Assessment 2010 Final Total Land and Building Date Price Code Deed Book/Page 2010 Final: 339100 Land Value: 151900 Acres: 1.16 8/1/1984 26000 01 CV 0441 / 1927 Assessed: 339100 Building Value: 187200 Ag.Credit: 0 Finished Area: 5000 SgFt Exempt: Taxable: Taxes: 7047.92 BUILDING INFORMATION Exterior Features View: RoofCover: SM - Sheet Metal RoofStruct: TR - Steel Rigid ExtType: INDF - INDUS-FLEX YearBlt: 1984 Frame: Grade: Y_D+ - Commer D+ EffYrBlt: 1984 PrimeWall: CM - Corr Metal StoryHght: 0010 - 1 Story No.Units: SecWall: Interior Features BedRooms: 0 Electric: MX - MAXIMUM PrmintWall: UN - UNFINISHED FullBath: 0 HeatType: FHA - FrcdHotAir AvgHUFI: STD 1/2Bath: 0 HeatFuel: ELEC - Electric Prm.Flors: CA - A TL/CON %A/C: 20 %Heated: 20 %Sprinkled: 100 Special Features and Yard Items Land Information Type Y/S Qty. Units Qual. Cond. YrBlt. No. Land Use Type Measure Depth CNC2 - CONCRETE LOW Y 1 1750 AV AV 1984 1 4100-LGHT MNFCT 310 -Sq Feet 50630.25 FEN6 - CHAINLINK 6' Y 1 875 AV AV 1984 BARB - BARB WIRE Y 1 875 AV AV 1984 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED http://www.pasic.org/prc.asp?prclid=142950100040006 6/20/2011