Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SUBMITTED PAPERS
DATE FILED: � PLAN REVIEW FEE: b RECEIPT NO.: PERMIT NUMBER 1 / v CONCURRENCY FEE: - RECEIPT NO.: CERT. CAP. NCI.: ALL INFO MUST BE COMPLETE & FILLED IN TO BE ACCEPTED PLANNING & DEVELOPMENT SERVICES DEPARTMENT BUILDING & CODE REGULATIONS DIVISION • ' 2300 Virginia Avenue /f Ft. Pierce, FL 34982-5652 772462-1553 APPLICATION for BUILDING PERMIT i r- CERTIFICATE of CAPACITY/ZONING COMPLIANCE PROJECT INFORMATION 1. LOCATION/SITE ADDRESS: SIB 0$ S. 1 VJ D R . , rl"• A 62CCJ1 F4 34� 2. PROJECT NAME: KcLrid %( tPOP-r SITE PLANNAME: 3. PROPERTY TAX ID #: 40 000 006140 Full Legal Description 136 40 FROM INT OF N LI OF GOV LOT 2 AND E LI OF FEC RR RUN SELY 1068.33 FT FOR POB,TH ELY TO IND RIV DR,TH NWLY 98.84 FT,TH WLY 688.74 FT TO FEC RR,TH SELY ON RR 97.4 FT TO POB, ALSO INCL LAND LYG E OF IND RIV DR AND THAT PART OF J F WOOTEN'S S/D N 50 FT OF - LOT IA -LESS RR AND RD RS/W- ALL WITH RIP RTS (4.13 AC) (OR 3181-710) 9. PARCEL SIZE (ACRES/SQ FT.): • i 3 rtC"5 LOT DRVIENSIONS: ige d Go r V d COMPLETE DESCRIPTION OF CONSTRUCTION PROJECT OR WORK ACTIVITY: C0rj S, RUC,-r A New SETBACKS (ACTUAL) FRONT: 7n p..2.5'BACK: V �: WS RIGHT SIDE•• ' /� TYPE OF CONSTRUCTION (Check f o111 � p*opriate boxes [ ] NEW CONSTRUCTION [ ] RESIDENTIAL [ ] OTHER (SPECIFY) LEFT SIDE: 3 1 . O Z� to 6 EXPANSION/ADDITION [ ] INTERIORRENOVATION [ ] COMMERCIAL [ ] INDUSTRIAL DESCRIPTION OF PROPOSED USE: SQ. FT OF CONSTRUCTION: 50 0 16. VALUE OF CONSTRUCTION: $ I X Q- <- I cv/���� 15. SF. FT 1st FLOOR: SO 0 Thevalue of construction is used to determine the amount of pennit fees to be assessed. St Lucie County reserves. the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction activities. If the value is $2500 or more, a RECORDED Notice of Commencement must be submitted with this application SLCCDV Form No.: 001-02 A,7t7Td - PJ. ArAJ S IwA-S rvk PMittri SCc- PA D Po S V D CA, f` PO f�.T 16 C��PoozT A-0.7-Cyr .1.1cL19Af-e#Q W-47W I l O s- 4 2S2 • N cW $ 01k V& y ' UPDATED % •t� C i. 0 b a j) W I T �S / �PPL�� �`l /i�t 6/25/09 4 IC(- VAl'vf OWNER INFORMATION NAME: R O a N 1 lr R & 1 Try 90S I IJ ADDRESS: 03 S. 1 !J o i A -A) {�.k v e p . bw CITY: r-ofzx P I V .R. G STATE: �r if ZIP: ' 4-1 2 PHONE (DAYTIME): c77-4 -4 - 1 " Y 4-4-3 Email: Re;wN t c-K Gz 1 so 4e 6-N* L •COA( IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE, PLEASE FILL IN NAME AND ADDRESS BELOW. FEE SIMPLE TITLEHOLDER: ADDRESS: CITY: PHONE (DAYTROE): (___) CONTRACTOR INFORMATION ST. of FL REG.CERT #: STATE: BUSINESS NAME: ©LQ Aj 6 f4L 1l� L 0 9AL QUALIFIERS NAME: 90 rV t t; I. L6 IIJ A A ADDRESS: CITY: PHONE (DAYTIME): (_) STATE: FAX NO. ST. LUCIE COUNTY CERT #: Email: FPJ ZIP: ARCHIT/ENGINEER: FArUt., W E L ADDRESS: t 9 $ A- :5 , c,J . 1 LrM O Qr ST i CITY: PoeT S A I 0 T LV Gl L STATE: 4 ZrP: 3 4-9 0 4- PHONE (DAYTIlVIE): (%% 7f S g8R'$ BONDING COMPANY: ADDRESS: CITY: MORTGAGE LENDER: ADDRESS: CITY: STATE: ZIP: STATE: ZIP: IMPORTANT NOTICE: When a permit is issued and it is not picked up within 60 days after notification it will be voided and returned to you by mail. l � 5 its OFFICE USE ONLY r I �I SECTION TOWNSHIP RANGE MAP NO. ZONING LAND USE LOT CVG % ; 0 TAZ NO. FLOOD ZONE FIRM MAP # I sz FLR ELV MAX HGT CONST TYPE OCCUP TYPE MAX OCCUP # OF FLRS WATER SEWER. SPRINT F_RS STORMWATER LOT OF REC Before l/1990 LOT OF REC After 111990 LOT SPLIT REQUIRED LOT SPLIT APPROVED REPORT CODE HABITABLE AREA RADON FEE FT LIBRARY IMPACT FEE PUBLIC B FEE CORRECTION PUBIC BID IMPACT FEE GENERAL PARKS IMPACT FEE SCHOOL IMPACT FEE ROAD IMPACT FEE CREDrr Y N LAW ENF IMPACT FEE FIRE/EMS IMPACT DRIVEWAY REQUIRED Y N DRIVEWAY FEE ADMINISTRATIVE VARIANCE FEE FEE SPECIFY SUBS MECHANIC ROOF (o ELECTRIC GAS NON -CONFORMING LOT OF RECORD MISCELLANEOUS FEES REQUIRED PLUMBING FEES DATE SENT TO ADDRESSING: / .REVIEWS FRONT CO ZONING REVIEW SUPERVISOR REVIEW PLANS REVIEW VEGETATION REVIEW SEA TURTLE REVIEW MANGROVE REVIEW DATE RECEIVED DATE INITIALS r- 1 Iti CEATNICATION: . This application is hereby made to obtain a permit to do the work and installations as indicated, and to obtain a certificate of capacity, if applicable, for the permitted work. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits may be required for ELECTRICAL, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AND AIR CONDITIONERS, FENCES, ETC., not otherwise included with this building permit application. St. Lucie County makes no repreientation that its granting of a permit will airthorize the permit holder to build the subject structure which is in conflict with any applicable Homeowner Association rules, bylaws or any covenants that may restrict or prohibit such structure. Please consult with your Homeowner's Association and review your deed for any restrictions which may apply. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures (all types), swimming pools, fences, walls, signs, screen rooms, utility substations & accessory uses to another non- residential use. NOTICE TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR R"ROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOBSITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE TO APPLICANT: IF IT IS NOT YOUR RIGHT, TITLE, AND INTEREST THAT IS SUBJECT TO ATTACHMENT: AS A CONDITION OF ISSUANCE OF THIS PERMIT, YOU PROMISE IN GOOD FAITH TO DELIVER A COPY OF THE CONSTRUCTION LIEN LAW NOTICE TO i THE PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT. OR CONTRACTOR SIGNATURE STATE OF FLORIDA ,rj— COUNTY OF.__ g�f/1 The foregoing instrument was acknowledged before me this day of 2 , who is personally known " or .has produced identification. CONTRACTOR SIGNATURE STATE OF FLORIDA COUNTY OF The foregoing instrument was acknowledged before me this day of , 20 by who is personally known or has produced as identification. Signature of Notary Signature of Notary DAWN MI6dNS Commission No. ) Commission No. (Seal) t„ MY D®MM1691bN i f�D 65P5fi7 EXPIRE& Mated N 2019 ttvndad• w NO(Aty holic Nd4rwr+t®rs NOTE: TWO (2) SIGNATURES ARE REQUIRED. EACH SIGNATURE MUST BE NOTARIZED. IF APPLYING FOR THIS BUILDING PERMIT AS AN OWNER/BUILDER, THE OWNER MUST PERSONALLY APPEAR TO SIGN THIS APPLICATION IN THE OFFICE LISTED ON THE FRONT OF THIS APPLICATION. OWNER BUILDER AFFIDAVIT WILL BE REQUIRED FOR ALL OWNER/BUILDER APPLICANTS. For specific instructions see appropriate permit checklist. 6 �1 PLANNING AND DEVELOPMENT SERVICES DEPARTMENT Building and Code Regulations Division 2300 VIRGINIA AVE. FORT PIERCE, FL 34982 (772)4624553 PERMIT RENEWAL REQUEST 1 ADDRESS: ��03 . ��� r R i i(&l- DQ- PERMIT NUMBER ` 0 23 I, IZ 0 N ftj IV S - !C� � L� � j , AM REQUESTING THAT THE ABOVE PERMIT IS RENEWED. I UNDERSTAND THAT I MUST SCHEDULE AND PASS ALL REQUIRED INSPECTIONS FOR THE T E:ALED. FURTHER, I UNDERSTAND THAT THIS IS A ONE TIME RENEW SHALL EXPIRE SHOULD I NOT RECEIVE A PASSING INSPECTION D G S OS PERIOD DURING THE RENEWAL PERIOD. OR CONTRACTOR SIGNATURE STATE OF FLORIDA, County of ACKNOWLEDGED BEFORE ME THIS a J?b DAY OF 8/7-7 L9 a DAT Ck1�d, ,20 13 BY �NOyn MQ- �R\ e•� `n WHO IS PERSONALLY KNOWN TO ME , OR HAS PROVIDED k - -13�1 5 — �� y a AS IDENTIFICATION. STATE OF FLORIDA, County of Q C- \ _ SEAL. SIGNATURE OAARY CONMSSIO �,iPKY Poa,� DEANNA GIVENS Notary Public - State of Florida •; My Comm. Expires Dec 16, 2016 Commission # EE 858761 Bonded Through National Notary Assn. FOR OFFICE USE ONLY: RENEWAL FEE: $ No. of Open Inspections _ Total No. of Inspections = (% of Open Inspections). Original Permit Fee $ x Open Inspections (%) _ $ (Renewal Fee). Example: [15 _ 23 = .65(%)] $175.00(permit fee) z .65(%) _ $113.75 (Renewal Fee) SLCPDSD REV 4/11/2011 I— Pe&- rGx; l I 'H t> e "c, rift-7 / 0 l < V U /-) CO (.vA4 0 S Pc r � Lrw � 1142 Water Tower Road, Lake Park FL 33403 R"�� I'i� it i�l' '-i ' �ifJik.'� }}u; ��J jii �H1 Administration Office: 1-877-484-9994 / Fax: 561-848-1501 pDts�atVch: South East Florida Division Dispatch:561-844-9994 / Central Florida Division 407-339- Concrete Tested ❑ Yes 5 Na' LOT # Water -Added at Customer's Cylinders Taken ❑ Yes UZO Request *� gals. to full load Comments gals. to 2/3 load gals. to 1 /3 load f Customer's Rep - Water Added NOT RESPONSIBLE FOR WARNING IRRITATION TO THE SKIN AND EYES ADDITIONAL WATER ADDED TO THIS VARIATION IN COLOR OR Cement polymer or freshly mixed concrete may cause skin injury. Avoid contact with skin and wash exposed skin areas promptly with water. If any cement powder or CONCRETE WILL REDUCE ITS STRENGTH SURFACE DISCOLORATION mixture gets into eyes, rinse immediately and repeatedly with water and get prompt medical attention. Keep children away from cement powder and all freshly mixed AND DURABILITY. ANY WATER ADDED IS AT CUSTOMER'S OWN RISK. BATCH TIME cement products. To Job On Job ;E�IIIIIIIIIIIII To Plant At Plant PLANT T(CKET# ORDER # TRUCK # LOAD SIZE MIX SLUMP DATE CUSTOMER # SOLDTO P.O. # PROJECT# DELIVERY ADDRESS ZONE# USE DRIVER INSTRUCTIONS TIME DUE PRODUCT CODE PRODUCT DESCRIPTION U.O.W UNIT PRICE SIGNATURE OR RECEIPT -CONCRETE AN 4 ACKNOWLEDGEMENT OFHAZARD WARNING . asc Meyer fo crate _ ompalry willnot assume ia. i i or any property damage or any SUB -TOTAL equipmertY darmage forj any deliaends beyond- curb line. 6 1 TAX AUTHORIZED BY J� Q SHIPMENT SUBJECTITO CONDITIONS ON REVERSE SIDE. TOTAL ` THIS DELIVEIV IS M&j2E2UBJECTT_QTHECONDITIONS.- .1 1. 11 . I , I kigi-oeto pravd4 a suitable roadway for our true as from the street pavement io th6 place of delivery Of mp,!�,riar. !t suwh suttabieroacKv" ays are not provided, we reserve, the, riqlhll to stop deliveries urml Gondifions are remedied arid, 76i i %tci customer will be held responsible for any loss caused thereby, 2 entati When dehveryis made beyond the or line at the customer orcustorner repres ve's request any damages ir-cluding, but lirnited to, sidewalks, driveways, buildings, trees, shrubbery, septic tanks and septic systerns. including the &air atilne owner's risk. Ti ,3 e custorner agrees to reimburse said Company for loss of time and equipmest by reason of such dell ry, and a;so to indemnify and save harmless said Company from any wid all claims, demands and suits for or an accouni of or in agy manner caused by or arising from private driveway delivery 4, 0 uisomer acknowledges that all materiatand services shown have been received, that trick dries shown are correct. ar,14 L , U that thR amount of water addedai the customer's request is shown correctly. CAUTION, The,,, addition of water i edunes conorate strength and durability. 5, We are not responsible for finished results obtained from this toad of concrete; many important factors affecting the uhimate u -t scrape of re;sponf,6ility and con'trol, I al: y of the completed job are beyond our sc ,P) A charge of $1 .00 per rninute will be charged after 8 minutes rercubic yard unloading tirne is exceeded. stomer agrees to provide a suitable wash down facility for our trucks and tools at the place of delivery of material, Y %Omer hereby Agrees to pay all costs and expenses of collection, including a reasonable a*�torne 'sfees iflie shall a',o iit pa y for the merchandise reflected in this invoice, when du-e. Past due accounts are subject to a 1-1/2% saervi.-e charge or the unpaid past due balance, The customer here!by acknowledges receipt of the complete copy of this contract. Si Lucie COUBW 2300 Via Avenue 34982 CERTMCATE OF TOTE TREATYA14T, CONSTRUCTION SOIL TREATMENT r OS ADDRESS. PsRIVDT # !__: J _ o PE9T CONTROL CONTIUCTOR SOQTHCO1�l.ST PEST CONTROL QC. PEST CONTROL LICENSE # JB 110 518 We, the undzrdg e 6 hereby certify that we have pretreated the above-d ed consiracfiton for subterranean termites in -accordance with the standards of the National Pest Control Association. Square feet of area treated: ,.D�t�� Perms of solution:: IDate Fooling - . Q istTmatment ❑ Roma Slab Q Ist Ro-treat . Qlist Q Rem Q Pools Q JstTrmUnwt Q Chenidcals used: Total gamons need: 15me of Treatment: �= - A wwI&wmz&mdJ0hsffcP0sft9 bvurdsha(IbePmvidedto�� dapa.W T p as each P , Ca"wkreApVY&ft a comf�thep"mm dwPuautisiswed to am ww*wCwjbr&Vpmnftim= 7'WTmmUemCwwftCawdmrft p vv dcdw pvdaanwt i&nWyaf&c, aseavddau gfdw sire bcagm am & ammt dr =gd uset a►ldmmnberofga u=04meaobd"avu�abkraewidofP�amctipe ifr� and a�ttiat7�arri�f�Prea►�ioisis iure+d rm denww shut[be pmrmfmdapProvaL. L3 +other ® 1st Treatment Q Re~ -treat r CI Perimeter for Final Inspection Signature of exterminator NOTE: h*dfnrm. fbreach re4u�ed &eatjwnt•orre-i =*neW =d this foray n be- There be a -camp on ordw whe&"ftWedion wi 9fwpb site io bePieked up by.t pe ' atimie o, f eQch.inispedi s 02-14-'12 10;08 FROM-A,M, Enga,nppring 772-924-3580 T-177 P0001/0001 F-40 A. M. ENGINEERING AND TESTING, INC. 590 N.W. MERCANTILE PLACE PORT ST. LuciE, FLORIDA 34986 OFFICE: (772) 924-3575 PAX: (772) 924-3580 REPORT OF SLAB & FOOTING COMPACTION Client: Ronnie S. Klein 5803 S. Indian River Drive Fort Pierce, Florida 34982 Site: 5803 S. Indian River Drive Fort Pierce, St. Lucie County, Florida Slab & Footings Report Date: Project No: Lab No: Technician: Permit No.: February 12-1029 R. Marchand 1105-0252 1111-0231 Density tests and Hand Cone Penetrometer (HCP) readings were made below footing and pad grade to a depth of one foot at a minimum of three locations. At the time of our testing no information was available regarding the foundation setbacks. The density tests were performed in general compliance with ASTM D 6938. The HCP test, in conjunction with information about the soil type, is empirically correlated to the relative density of subsurface soils. Density TestNo. Date Tested Location Wevation (feet) Dry Densit Percent Comipacgon InPlaee Proctor 1 2/10/12 West Footing 0- 1* 1053 IOU 97.5 2 North Footing 0- V 106.0 108.0 98.1 3 Southeast Corner 0 -1** 106.2 108.0 98.3 4 Center Area 0 -1** 1053 97.9 5 Northwest Corner 0 -1*e 105.7 HMO 97.9 Elevations are below bottom of footing. Elevations are below bottom of slab. In the locations and depths that were tested, the soil beneath the footings has been compacted to a minimum of 95 percent of the modified Proctor maximum dry density (ASTM D 1557). No soil borings were performed below the recently placed fill. Distribution: Client — 2 Email — ronklein(@rskesine.com PCM/em V. A. A. EN Q EERING AND ITE41NG, INC. lVlorfin Florida. Regisb'n ,NO: . 65051. • F:1C O. R, JobslKleln, Ronnie SI5803 & Indian River Dr., Ft. PiereeW,1029 -Slab & Footing Den-doc JOSEPH E. SMITH, CLERK 01:' •1•kik; L:1Kt;Ut1• UUUAT - OkL-LLvl 1+Uk--LZ FILE # 3649917 OR BOOK 334', �IAGE 2760, Recorded 11/22/2011 at Of=,: PM NOTICE OF COMMENCEMENT Permit•No. 1k1i— 01-11 Tax Folio No-340 -423-000I- OOO/1O State of Florida County of St. Lucie fhe undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. Legal Description of Property: (and street address if available): 1 _` I o .f General description of improvement: Cows f aye- r IV d w f af0 7 i- z s ics,8- pO.&T /SLrT� ~o M✓TA-f— 12a0E- Owner Information or lessee Informallon If the Lessee contracted for Imp vemenr_ , Name address Interest in property: 60 as rc Name and address of fee simple titleholder (if different from Owner listed above): Contractor's Name: ROICIIL!(fd 4CLU/rt) COW 00VIR- 0dP-1 Contractor Address: Phone Number: Surety (if applicable, a copy of the payment bond is attached): Amount of bond: $ Ad& -_ Name and address: Phone number: _ Lender Name: AJ/�' Phone Number: ender's address: Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1) a)7., Fda Statutes: �� 2 Name: AlloriS. t;f� s% Phone jJu�r: i d'0 I -�9�e �4 Address: �-i O 3 � 1._ In addition to himself or herself, Owner designates of Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Phone number of person or entity designated by owner: to receive a copy of the Expiration date of notice of commencement: (the expiration date may not be before the completion of construction and final payment to the contractor, but will be 1 year from the date of recording unless a different date Is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST !NSPECTION. IF YOU INTEND TO 0 TAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF C , 4MENCEMENT. Under1peltyf p I ryclare that I have read the foregoing notice of commencement and that the facts stated therein are true to the best of myknnd r (S' ature of Owner or Lessee, or Owner's or Lessee's Authorized Officer/Director/Partner/Manager 10EVN0R- (Signatory s Title/Office) r qq AA..v^ °cam The for oing instrument was acknowledged before me this day of'u . ei ,v 0 uJN•� 2 By as ame of Person Type of authority (e.g.officer,trustee 1 nJnn 9f ::�'�;,. w"" 1 4 DAYMMILONE MYCOMM{9310NADDP52E�!Y I•: (Signature of Notary Public -State of FI ;,f pXPIREB; Mtlrcn 2�, 2013 Type, or Stamp Commissioned N m¢,; otdfjr�Fd�HIRfI°u'I'�AUndenaners (Print, zot F for Party on behalf of om instrument was executied f , Personally known_or produced Identificatior0Fr- 2011 Type of Identification produced �j I?'l'I P1ta STATE OF FLORIDA ST. LUCIE COUNTY St. Lucie County, Ft_ Tn rrD7IrV TWATTFIIR IS A NOTICE OF COMMENCEMENT Permit No. �1 1 — 023 Tax Folio No.340 1 "41' A"r)A2 JOSEPH E. County i SAINT L CIEyC UNCLERK OF THE CIRCUIT COURT State of Florida of St. Lucie FILE # 3649917 11'22/2011 at 04:14 Phl The undersigned hereby gives notice that improvement will be made to certain real prof OR BOOK 3341 PAGE 2760 - 2760 Doc Type: INC RECORDING: $10.00 ,he following information is provided in this Notice of Commencement. Legal Description of Property: (and street address if available): --General-description-of improvement: Cm�� L �z�GT POW cGO `ic 2 5 ` CIF1-fZ. �� � W .SG.4%3 Owner information or Lessee information if the Lessee contracted for _e im r vement- - •lame — Qot� L - l ro it - :- - -- --Address_ ie1 v [�� Est [! Jet Z� - ___ Interest in property:. _ O AJ -Name and address of fee simple -titleholder (if different from. Owner -listed -a bove):— Y1i Contractor's Name: R0x 4 g 4�LIOW ( �� N td�t ��� �'� • Contractor Address: _ Phone Number: Surety (if applicable„a. copy of the payment bond is attached): Amount of bond: $ Name and address: Phone number: Lender Name: �`'��" Phone Number: lender's address: Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1) a)7., Florida Statutes: Name: A.)PO & S• 4(>'I L) Phone Number: "7'7Z" �'� l �_� �� 3 Address:6-a0 3 ��1 1'V ® 1PrLJ �-1 ft V"YL b 0Z ipIQ.J P1 P*e r% )rG .In addition to himself or herself, Owner designates Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Phone number of person or entity designated by owner: to receive a copy of the Expiration date of notice of commencement: (the expiration date may not be before the completion of construction and final payment to the contractor, but will be 1 year from the date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO O 'OPTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR (iECORDING YOUR NOTICE OF C VI•MENCEMENT. Onder pe Ity f pVa/ry/7 re that I have read the foregoing notice of commencement and that the facts stated therein are true to the best of my kno le7d and of Owner or Lessee, or Owner's or Lessee's Authorized Officer/Director/Partner/Manager (Signatory's Title/Office) J The for oing instrument was acknowledged before me this ll- day of /�� " 20_/ B rY r - /II j ��/ N as �.I (�Ai—P . i for � I F --Tame of Person Type of authority (e.g.officer,trustee) Parry on behal�ofom instrument was executied �" l� c Mm5r, '1, DAWNMILONE personallyknown_orproducedldentification of NotaryPublic - State of F° MY XPIRIE COMMISSION 22DD 9 013 2587 (Signature I�i4PIFiESt M�ren i'�, 2013 (Print, Type, or Stamp Commissioned et ptp6otarypublleUnderwriters Type of Identification produced PLANNING &.DEVELOPMENT SERVICES DIVISION BUILDING & CODE REGULATIONS DIVISION 2300 Virginia Ave Fort Pierce, FL 34982 BUILDING PERMIT SUB -CONTRACTOR SUMMARY �IV A) Y ,- L L / will be using the following sub -contractors for the (company/Individual Name) project located at 3 �• � Ili 1 1 A N �1 V Ci �. )R • (Street address or Property Tag ID P �, 3 d, 9 Z It is understood that if there is any change of status regarding the participation of any of the sub -contractors listed below, I will immediatelyadvise the Building and Zoning Department of St Lucie County. Trade Name of +Company/Confmctor" - St. Lucie County/ -" - St$te- of oridaT License Number Electrical G�/✓/�� r`' L dl IJ p c� Av&I .- Plumbing HVAC/ Mechanical Roofing ®�A.) Gas OFFICE -USE ONLY: PERNIIT ISSUE DATE: NUMBER: 1 _ PLANNING & DEVELOPMENT SERVICES DEPARTMENT BUILDING &CODE REGULATIONS _DIVISION BUILDING PERMIT SUB -CONTRACTOR AGREEMENT -St. -Lucie County Contractor Certification Number: State of Florida Certification Number (If applicable): R.Oa�N ce �L(3'/� have agreed to be the - - - - - -- - (Company Name&di- i&WName) - --- _- - --:. -- - - ---- -- - - -- --- -- -- --, - --- -- �l.(TGCi�C. sub -contractor for (Type of Trade) (Primary Contractor) --- 8�3-5:1W ol, +2� ✓sae.—D —%�%P� ecr!' — for the project located it (Project Street Address or Property Tax ID #) rG 3 ¢9 2 It is understood that, if there is any change of status regarding our participation with the above mentioned project, I will immediately advise the Building and Zoning Department of St. Lucie County by personally filing a Change of Contractor notice: (Form: SLCCDV No. 004-00) Business Name: Address: City/State/Zip: Phone: (Name of the Individual shown on the Contractor's License) REQUIAED V,0,4w)//e GGLc�i PRINT NAME DATE o00&Yz 6vt L. V2 OFFTrE ITSF ONLY: r � i PLANNING & DEVELOPMENT SERVICES DEPARTMENT ' ^ - BUILDING & CODE REGULATIONS ,DIVISION BUILDING PERMIT SUB -CONTRACTOR AGREEMENT ^St Lucie County Contractor Certification Number: State ofFloridaCertification Number afamicable): have agreed to be the _ ___ - - -------(Company NaffidIddividu�la .Name)_ _ sub -contractor for (Type of Trade) (Primary Contractor) for the project located atgD (Project Street Address or Property Tax ID #) �:3498Z It is understood that, if there is any change of status regarding our participation.with the above mentioned project, I will immediately advise the Building and Zoning Department of St. Lucie County by personally filing a Change of Contractor notice. (Form: SLCCDV No. 004-00) Business Name: Address: CityLstate/Zip: Phone: (Name of the Individual shown on the Contractor's License) ,p; l z . �,vair� ftiGdrst% PRINT NAME DATE 0C0A)&Te- n1'TTrTi 7TQ1V rnvr.V- email: v PERMIT # ISSUE DATE St. Lucie County Building & Zoning Department 2300 Virginia Avenue Fort Pierce, Florida 34982 (772) 462-1553 OWNER/BUILDER AFFIDAVIT DISCLOSURE STATEMENT F.S. 489.103 (7) EXEMPTIONS State law requires construction to be done by licensed contractors. You have applied for a permit under an exemption to that law. The exemption allows you, as the owner of your property, to act as your own contractor even though you do not have a license. You must provide direct, on -site supervision of the construction yourself. You may-build_or improve farm outbuildings, a one -family or two-family residence or a commercial building_ at a cost of under $75,000.00. The building or residence must be for your own occupancy. It may not be built or substantially improved for sale or lease. If you sell or lease a building you have built or substantially improved your self within ---one-year-after the construction is complete, the --law will -presume -that you built -or substantially improved it --for sale - — or lease, which is a violation of this exemption. You may not hire an unlicensed person to act as your contractor or to supervise people working on your building; it is your responsibility to make sure that people employed by you have licenses required by state law and by county or municipal licensing ordinances. You may not delegate the responsibility for supervising work to a licensed contractor who is not licensed to perform the work being done. Any. -.person working on your building who is not licensed must work under your direct supervision and must be ._employed_ -by you,_.which .means -that--you must_ deduct F.I.C.A. and withholding tax and provide workers'. - compensation for that employee, all as prescribed by law. Your construction must comply with all applic ordinances, building codes, and zoning regulations. Initial I understand that the building official and inspectors are not there to design or give advice on ho t the minimum code. Initial I understand that as an owner -builder that any contract disputes with sub -contractors and I must be in a civil court with the advice of an attorney. This department will not mitigate any contract disputes. Initial I understand that if I compensate any person or company for work performed they are requir e licensed in this jurisdiction. If for some reason they do not possess a license, I may be responsible and lia he cost of the license. Initial I understand that if any person that is unlicensed and uninsured gets injured on my constructio t- they may be entitled to workmen's compensation. I could be held liable for all doctor, lawyer and relat al cost, which could include loss of wages during recovery from their injury. Initial To qualify for this exemption under this subsection, an owner must personally appear and sign the building permit application and initial the above. I hereby acknowledge that I have read and understand the above disclosure state nt and that I further understand that any violation of the terms of the owner/builder exemption 1 be p rt d y the Building and Z,o'm� g Department to the Florida Sta.t��jj Department of Professional Regul do S' e cknowledZ, on this day of AJO V of 20 7. Signature STATE OF FLORIDef�'$ COUNTY OF )! The regoing instr)Ze t was apknowledged before me this day of 20 by !� `� /� e1 who is personally known to me, or who has oduced as identification. V``ngir lay, e ignature of Notary L Type or Print Name of Notary F, Title: Notary Public Commission Number °�a'" ���(" p _ MY COMMISSION # DD 852587 ?, EXPIRES: March 22, 2013 Bonded Thor Notary Public Underwriters l PLANNING & DEVELOPMENT SERVICES DEPARTMENT BUILDING & CODE REGULATIONS DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 (772) 462-1553 FILLED LANDS AFFIDAVIT I, the undersigned, am the ovkmer of the following described property, ,17e03 $ . /.v 0 /q-s0 Ri c/ G'12 DP — _co R.r- Pi ep2 c o - )c L 3 4-9'8 Z (Parcel Id#/Legal description/Ad ess) for which I have applied to St. Lucie County for a Final Development Permit. In accepting this Final Development Permit, BP Number 1 u % "0,�23% I acknowledge that as owner of the above described property, and in accordance with Section 7.04.01(D), St. Lucie County Land Development Code, I shall be responsible for assuring adequate drainage so that the immediate community WILL NOT be adversely affected. I further acknowledge that in granting this permit for the development of this property, St. Lucie County is neither obliged nor liable to provide for, or maintain in any form, adequate drainage off my property which will not adversely affect the immediate cnmmimity_ 1,1 22 20 t l Date STATE OF FLORIDA, COUNTY OF ACKNOWLEDGED BEFORE ME THIS n l2� DAY OF ?A20 BY A Min 1 =e I (I v WHO IS PERSONALLY KNOWN TO ME OR WHO HAS SIGNATURE OF NOTARY PUBLIC COMMISSION NUMBER SLCPDSD Revised 08/24/2010 AS IDENTIFICATION. h IYIi' (fin o TYPE OR—PMNT NOTARY 1�r''••. DAWN MILONE e MY COMMISSION 4 DD 852587 EXPIRES: March 22, 2013 Bondod Thru Notary Public Underwriters OFFICE USE ONLY: 11 11 "\- AI 0DJ PERMIT # — DATE FILED- --REC-EIPT# REVISION FEE. im 11 -lf�,Z' —: PLANNING & DEVELWAM F MPINIMRFEW-��' , '-;4, ..� BUILDING & CODE REGULK '�",OUNTY 2300 VIRGINIA AVE -A L 0 R I D. A (772) 4624553 3. ' 4. APPLICATION FOR BUILDING LOCATION/SITE ADDRESS: CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: BUSINESS NAME: QUALIFIERS NAME: ADDRESS: CITY. PHONE (DAYTIME). OV,qqFJMURDER INFORMATION: NAM: —Ropi ADDRESS: CITY: PHONE: A -p- I _Vd- ST. LUCIE COUNTY CERT. #-. STATE: FAX: STATE: WA cz- 21P: -Jo -1 FAX: =7 5. ARCHITECTIENGINEERI[NFORMATION, NAME: P4 ADDR ESS %L:9J-M CITY: r, PHONE(DAYTIME): :1�2� FAX - SLcCC: 9123109 Revised 04/26/2010 "Al ZIP: go Engineering Index Sheet Page 1ofI ?ermit Number: Lot Number #: tt Address- Miscellaneous:Indi;i6RiverDnue.-`:? information in this box is for administrative purposes only and is not part of the engineering review. r Ft PIerCE F/'St Luce,4�Y T'Ifs Fabricator :East Coast Truss :Cl eint..'i<Ieln, .Ror ,; i` Job NarridWein Re -Roof : � 2213- ^ " Date: 09/30/11 Job Number:Specification Quantity: 51 t. ,., . Note:--'`� A Professional Engineers Seal affixed to this Index Sheet indicates the acceptance of professional B U ding Code Engineering responsibilities for individual truss components fabricated in accordance with the listed F BC2007/TP 12002 and attached Truss Specification Sheets. Determination as to the suitability of these individual truss components for any structure is the responsibility of the Building Designer, as defined in PAUL A. BEATTY, P.E. / LICEN�,E # 47449 ANSI/TPI 1-95, Section 2.2. Permanent files of the original Truss Specification Sheet are maintained P.o. B;m,V"11A by East Coast Truss. Ques'ions regarding this Index Sheet and/or the attached Specification Sheets �d�NQQ+ •,......., 'g%'J.°,�, may be directed to East Coast Truss @ 772-466-2480. ���� G,RT I ���'.� j •.• �"°s * • G Standard Roof Loading: 1�4744_9FRS (low-rise)ASCE 7-05 lr T.C. Live: 20.00 psf -A T.C. Dead: 7.00 psf I 150.000 MPH s� :• STATE OF r .� 4 fit! B.C. Live: 0.00 psf �-.. _ Exp Cat. C � n '• �� B.C. Dead: 5.00 psf Enclosed Bldg �•'o�o�Fs'•F�OfZ1D4:•'��C���� Total Load: 32.00 psf joi�S fQNAL �Es ;,�e`� Notes: Refer to individual truss design drawings for special loading conditions. No. Date Truss ID# 1 08/09/11 A01 2 08/09/11 A02G 3 08/09/11 A03 4 08/09/11 A04 5 08/09/11 A05G 6 08/09/11 A06 7 08/09/11 A07 8 08/09/11 A08 9 08/09/11 A09 10 08/09/11 A10 11 08/09/11 All 12 08/09/11 Al2G 13 08/09/11 B01 14 08/09/11 B02 15 08/09/11 B03G 16 08/09/11 B04G 17 08/09/11 C01 18 08/09/11 CO2 19 08/09/11 CO3 20 08/09/11 C04G 21 � 109411 D01 22 /091.1 1 D02 23 'a%06111, D03 24 08/09/11 D04G 25 09/30/11 E01 26 09/30/11 E02 27 09/30/11 E03 28 09/36/11 E04G 29 08/09/11 FG02 No. Date Truss ID# 30 08/09/11 MV5 31 08/09/11 MV7 32 08/09/11 MV9 33 09/30/11 —CJ1 34 08/09/11 —CJ1A 35 09/30/11 —CJ1B 36 08/09/11 —CJ1v 37 08/09/11 —CJ3 38 08/09/11 —CJ3A 39 09/30/11 —CJ3B 40 08/09/11 —CJ3v 41 08/09/11 —CJ5 42 1 08/09/11 —CJ5A 43 09/30/11 —CJ5B 44 08/09/11 --CJ5V 45 08/09/11 —EJ7 46 09/30/11 —EJ7B 47 08/09/11 —EJ7V 48 08/09/11 —HJ7 49 08/09/11 —HRA 50 09/30/11 —HJ7B 51 08/09/11 —HJ7V PAUL WELCH INC. M MECH-ELECT-CIVIL ENG 1984 BILTMORE ST. #114 PORT ST. LUCIE, FL 34984 PAUL WELCH, P.E. FLA REG NO 29945 OCT 1 42011 • Ji,,!LV-! C+ A 1-,:_ With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this Page 1 of 1 index sheet conforms to 61 G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. A01 I Common Truss 22137-Klein, Ej t1- f PIERCE, FL. 34946 7. 3 6-10-14 6-1-2 4.00 12 5� _ s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:20:57 2011 Page 1 ID:ZycEGXaGi5uaivlhsBRj37zPYdX 5ltOjf2jCdeUzfllY208UUQKD1Pi436g6938AQyYUOq 6-1-2 6-10-14 2-0-0 Scale=1:49.3 Camber= 1/8 in 3x4= 3x4= 3x4= M= 3x6 = 940#/-1390# 940#/-13909 Id LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 ' BCDL 5.0 SPACING 2-0-0 Plateslncrease 1.25 Lumberincrease 1.25 Rep Stress Incr YES Code FBC2007/TP12002 CSI TC 0.38 BC 0.42 WB 0.41 (Matrix-M) DEFL in Vert(LL) 0.22 Vert(TL) -0.22 Horz(TL) -0.07 (loc) I/deft Ud J-L >999 240 J-L >999 180 H n/a n/a PLATES GRIP MT20 244/190 Weight:139 lb FT = 20% LUMBER BRACING TOPCHORD 2X6SYP No.2 TOPCHORD Structural woodsheathing directly applied or5-8-4 oc BOTCHORD 2 X 4 SYP No-2 purlins. WEBS 2 X 4 SYP No.3 BOTCHORD Rigid ceiling directly appliedor4-2-11 ocbracing. MiTek recommends thatStabilizers and required cross bracing be installed during truss erection, in accordancewith Stabilizerl nstallation guide. REACTIONS (lb/size) B=790/0-8-0, H=790/0-8-0 MaxHorzB=211(LC 4) Max UpliftB=-1390(LC 6), H=-1390(LC 7) Max Grav B=940(LC 2), H=940(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD B-C=-188312383,C-E=-1638/2098,E-G=-1638/2099,G-H=-1883/2385 BOTCHORD B-L=-2219/1739,J-L=-1293/1199,H-J=-2017/1739 WEBS E-J=-643/475, G-J=-369/723, E-L=-642/475, C-L=-369/722 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveloads. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrentwith any other live loads. 5) "This truss has been designed for alive load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Prcylide mechanical connection (by others) of truss to bearing plate capable of withstanding 1390 lb uplift atjointM and 1360 lb uplift atjoint P. 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAU1CASE(S) Standard J� Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof A02G Common Truss 1 1 Job Reference o tional 6sv? Coast Truss, FORT PIERCE, FL. 34946 /.250 s May i .i 20i i ivu 1 eK industries, inc. Fri Sep au i 0:2-1:0 1 20-I l rage -i ID•ZY cEGXaGi5uaiv1hsBR'37zPYdJ YXzo6vZ15DGs9wSGb3nus4flQ3xMenx0m2P1n1MJB YUOm � 2-0-0 93� 3 8 12 3 8 12 9-34 2-0-0 1 Scale=1:49.3 Camber=1/16 in 4.00 12 5x6 = B Ti •^"' C T2 2 T2 7x6� E T1 F G Ia B' B2 J I H 3x6 — 3x4 = 4x6 3x4 = 34 = 1154#/-1755# 1154#/-1755# 9-0h 7-5-8 9-3-4 2-0 0 26-0-0 2-0-0 Plate Offsets (X Y): [B:0-2-6 0-0-2] [C:0-3-0 0-4-8] [E:0-3-0 0-4-81 [F:0-2-6 0-0-2] LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plateslncrease 1.25 TC 0.69 Vert(LL) 0.24 H-J >999 240 MT20 244/190 TCDL 7.0 Lumberincrease. 1.25 BC 0.40 Vert(TL) -0.19 H-J >999 180 BCLL 0.0 * : Rep Stress Incr NO WB 0.80 Horz(TL) -0.06 F n/a n/a BCDL 5.0 Code FBC20071TP12002 (Matrix-M) Weight: 159lb FT = 20% LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD BOT CHORD 2 X 6 SYP No.2 WEBS 2 X 4 SYP No.3 BOT CHORD REACTIONS (lb/size) B=968/0-8-0, F=968/0-8-0 Max HorzB=-211(LC 5) Max UpliftB=-1755(LC 6), F=-1755(LC 7) Max Grav B=1154(LC 2), F=1154(LC 2) FORCES (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD B-C=-2352/3169,C-D=-2335/3429,D-E=-2335/3430,E-F=-2352/3170 BOTCHORD B-J=-2908/2167,H-J=-1974/1600,F-H=-2706/2167 WEBS D-H=-1456/901, E-H=-372/762, D-J=-1455/901, C-J=-372/762 Structural wood sheathing directly applied or4-10-15 oc purlins. Rigid ceiling directly applied or4-5-10 oc bracing. MiTek recommends that Stabilisers and required cross bracing be installed during truss erection, in accordancewith Stabilizer) nstallation guide. NOTES 1) Unbalanced roof live loads have been considered forthis design. 2) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and rightexposed ; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveloads. 4) This truss has been designed fora 10.0 psf bottomchord live load nonconcurrentwith any other live loads. 5) *This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3=6-0 tall by 2-0'.•0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1755 lb uplift atjoint K and 1755 lb uplift atjoint N. 7) "Sgmi-rigid pitchbreaks including heels" Memberend fixity model was used in the analysis and design of this truss. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 214 lbdown and 363 lb up at 9-3-4, and 214 lb down and 363 lb up at 16-8-12 on bottom chord. The design/selection of such connection device(s) isthe responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). Continued on page 2 Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof L A02G Common Truss 1 1 Job Reference (optional) Coast Truss, FORT PIERCE, FL. 34946 LOADCASE(S) Standard 1) Ragular: Lumber Increase=1.25,Plate Increase=1.25 Uniform iform Loads (plf) � 4 Vert: A-D=44, D-G=-44, K-N=-10 Concentrated Loads (lb) Vert: H=-178(F) J=-178(F) 7.250 s May 11 2011 MI I eK Industries, Inc. Fri Sep 30 1 U:L1:U1 ZU11 rage 2 ID:ZycEGXaGi5ua7iv1 hsBRj37zPYdX zo6vZ15DGs9wSGb3nus4fa)NenxOm2P1 n1 MJByYUOm L. Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof � A03 Hip Truss 1 1 c Job Reference (optional) >3ast Coast Truss, FORT PIERCE, FL. 34946 7.250 s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:21:04 2011 Page 1 i b ID:ZycEGXaGiSuaivlhsBRj37zPYdX NNo1B286ZnXVJjKeS1QnGyDUirm5DGXsjlGOvWyYUOj 2-0-0 5-10-14 5-1-2 4-0-0 5-1-2 5-10-14 2-M 6A = 5)0 _ 3x8 = 4A = 3A = M = 3S _ 940#/-1420# Scale=1:50.1 Camber = 3/16 in 940#/-1420# 2-0-0 26.0-0 2-M Plate Offsets MY): [B:0-3-12,0-1-81,[E:0-5-4,0-2-121,[G:0-3-12,0-1-81 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plateslncrease 1.25 TC 0.49 Vert(LL) -0.22 I-Q >999 240 MT20 244/190 TCDL 7.0 Lumberincrease 1.25 BC 0.56 Vert(TL) -0.42 I-Q >737 180 BCLL 0.0 " Rep Stress Incr YES WB 0.24 Horz(TL) -0.08 G n/a n/a BCDL 5.0 Code FBC2007/TP12002 (Matrix-M) Weight: 147lb FT=20% LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD Structural woodsheathing directlyapplied or5-8-6 oc BOT CHORD 2 X 4 SYP No.2 purlins. WEBS 2 X 4 SYP No.3 BOT CHORD Rigid ceiling directly applied or4-1-8 ocbracing. MiTek recommends thatStabilizers and required cross bracing be installed during truss erection, in accordancewithStabilizerinstallation quide. REACTIONS (lb/size) B=790/0-8-0, G=790/0-8-0 Max Horz B=-188(LC 5) Max UpliftB=-1420(LC 4), G=-1420(LC 5) . Max Grav B=940(LC 2), G=940(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD B-C=-1892/2523,C-D=-1488/1937,D-E=-1385/1936,E-F=-1495/1936, F-G=-1893/2526 BOTCHORD B-K=-2341/1753,1-K=-1532/1383,G-1=-2157/1754 WEBS C-K=-418/784, D-K=-221 /266, E-1=-222/267, F-1=-420/789 NOTES 1) Unbalanced roof live loads have been considered forthis design. 2) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and rightexposed; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveloads. 4) Provide adequate drainage to preventwaterponding. 5) Thig truss has been designed for a 10.0 psf bottom chord live load nonconcurrentwith any other live loads. 6) "This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any othermembers. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1420 lb uplift atjoint L and 142"J lb uplift atjoint 0. 8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOADCASE(S) Standard Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof A04 Hip Truss 1 1 Job Reference o tional last Coast Truss, FORT PIERCE, FL. 34946 1 2-M 6)S = 4.00 [W-6ES 7.250 s May 11 2011 MI I eK Inaustrles, Inc. Fri Sep 3u 1U:21:U/ GU11 rage 1 ID:ZycEGXaGi5uaivl hsBRj37zPYdX-oyUAp4Adv3AB3D79zUubr?X3gCQfplQjUgWryYUQg 7x6 = 4x4 = 1A 11 3x4 = 3x4 = 4x4 = 940#/-1450# 2-0-0 Scale=1:50:1 Camber = 1 /8 in 940#/-1450# 2-M 26-0-0 2-M Plate Offsets (X Y): [C:0-5-4 0-3-81 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plateslncrease 1.25 TC 0.49 Vert(LL) 0.22 I-L >999 240 MT20 244/190 TCDL 7.0 Lumberincrease 1.25 BC 0.41 Vert(TL) -0.22 I-L >999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.08 Horz(TL) -0.08 E n/a n/a BCDL 5.0 Code FBC2007/TP12002 (Matrix-M) Weight: 132lb FT=20% LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD Structural wood sheathing directly applied ors-7-12 oc BOT CHORD 2 X 4 SYP No.2 purlins. WEBS 2X4SYP No.3 BOTCHORD Rigid ceiling directly applied or4-2-8 oc bracing. WEBS 1 Row atmidpt C-G MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordancewithStabilizerinstallation uide. REACTIONS (lb/size) B=790/0-8-0, E=790/0-8-0 Max HorzB=-165(LC 5) Max UpliftB=-1450(LC 4), E=-1450(LC 5) Max Grav B=940(LC 2), E=940(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD B-C=-1737/2275,C-D=-1589/2293,D-E=-1740/2277 BOTCHORD B-1=-2034/1583,G-1=-2033/1587,E-G=-1872/1585 NOTES 1) Unbalanced roof live loads have been considered forthis design. 2) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. 11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for basic load combinations, which include cases with reductions formultiple concurrent liveloads. 4) Provide adequate drainage to preventwaterponding. 5) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrentwith any other live loads. 6) "This truss has been designed fora live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1450 lb uplift atjointJ and 1450 lb uplift atjoint M. 8) "Srami-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof A05G Hip Truss 1 1 Job Reference o tional fast Coast Truss, FORT PIERCE, FL. 34946 7.250 s May 11 2D11 MI I ek Industries, Inc. Fri Sep 30 1 U:2i:13 20i -i rage 1 t ID:ZycEGXaGi5uaivlhsBRj37zPYdX d6rR47FIRWDu6WNUQ4uas5?9Um9gHUAoex k\/yYUOa _I 2-0-0 7-" 6-0-0 6-0-0 7-0-0 2-" Scale=1:50.1 Camber= 1/4 in 5v1 n MTI AH= v W J X Y 4x12 = 1x4 II 4x6 = 1x4 II 3x10 = 1655#/--2571# 4x12 = 1710#/-2685# Plate Offsets (X Y)' LOADING (psf) i TCLL 20.0 TCDL 7.0 BCLL 0.0 * BCDL 5.0 [B'0-0-0 0-0-4] [C'0-5-8 U-2-12]IL'U-5-tt SPACING 2-0-0 Plateslncrease 1.25 Lumberincrease 1.25, Rep Stress Incr NO Code FBC2007/TP12002 U-2-121 [t-'tdge CSI TC 0.64 BC 0.89 WB 0.45 (Matrix-M) u-U-41 DEFL in Vert(LL) 0.72 Vert(TL) 0.57 Horz(TL) -0.22 (loc) I/deft Ud H-I >435 240 1 >547 180 F n/a n/a PLATES GRIP MT20 244/190 MT18H 244/190 Weight: 139lb FT = 20% LUMBER BRACING TOP CHORD 2 X 6 SYP SS TOP CHORD Structuralwood sheathing directly applied or3-6-15 oc BOT CHORD 2 X 4 SYP No.2 purlins. WEBS 2X4SYP No.3 BOTCHORD Rigid ceiling directly applied or2-6-0 oc bracing. WEBS 1 Row atmidpt C-1, E-I MiTek recommends thatStabilizers and required cross bracing be installed during truss erection, in accordancewithStabilizerinstallation uide. REACTIONS (lb/size) B=1397/0-8-0, F=1443/0-8-0 MaxHorzB—,142(LC5) Max UpliftB=-2571(LC 4), F=-2685(LC 5) Max Grav B=1655(LC 2), F=1710(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD B-C=-3967/5769,C-D=-4895/7401,D-E=-4895r/401,E-F=-4129/6101 BOTCHORD B-K=-5340/3697,1-K=-5350/3714,H-1=-5520/3867,F-H=-5510/3850 WEBS C-I<=-182/480,C-1=-2154/1396,D-1=-767/1435,E-1=-1821/1231, E-H=-178/480 NOTES 1) Unbalanced roof live loads have been consideredforthis design. 2) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat.11; Exp C; enclosed; MW_FRS (low-rise) gable end zone; cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveloads. 4) PrOvide adequate drainage to preventwaterponding. 5) All'plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrentwith any other live loads. 7) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-C`-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 2571 lb uplift atjoint L and 2685 lb uplift atjoint O. 9) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. Continued on page 2 Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 1 A05G Hip Truss 1 1 Job Reference (optional) ast Coast Truss, FORT PIERCE, FL. 34946 7.250 s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:21:13 2011 Page 2 ID:ZycEGXaGi5uaiv1hsBRj37zPYdX-d6rR47FIRYfDu6WNUQ4u8s5?9Um9gHUAoex kVyYUOa NOTES ' 10)'Manger(s) or other connection device(s) shall be provided sufficientto support concentrated load(s)113 lbdown and 281 lb up at 7-0-0,113 lbdown and 281 lb up at 9-0-12, 113 lb down and 281 lb up at 11-0-12,113 lb down and 281 lb up at 13-0-0,113 lb down and 281 lb up at 14-11-4, and 113 lb down and 281 lb up at 16-11-4, and 234 lb down and 587 lb up at 19-0-0 on top chord, and 265 lb down and 240 lb up at 7-0-0, 49 lb down and 8 lb up at 9-0-12, 49 lb down and 8 lb up at 11-0-12, 49 lb down and 8 lb up at 13-0-0, 49 lb down and 8 lb up at 14-11-4, and 49 lb down and 8 lb up at 16-11-4, and 265 lb down and 240 lb up at 18-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOADCASE(S) Standard 1) Regular: Lumberincrease=1.25, Plate lncrease=1.25 Uniform Loads (plf) Vert: A-C=-44, C-E=-44, E-G=-44, L-O=-10 Concentrated Loads (lb) Vert: C=-94(B) E=-192(B) K=-1 95(B) 1=-23(B) D=-94(B) H=-195(B) R=-94(B) S=-94(B) T=-94(B) U=-94(B) V=-23(B) W=-23(B) X=-23(B) Y=-23(B) Truss Truss Type 22137-Klein, Ron -Klein Re -Roof X 22137 A06 Monopitch Truss jQty 1 Tly 1 Job Reference (optional) ast Coast Truss, FORT PIERCE, FL. 34946 7.250 s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:21:15 2011 Page 1 ID:ZycEGXaGi5uaiv1hsBRj37zPYdX ZUzBVpG7z9vx7Qgmbg7MDHAJWHYRIIOTFyQ5oNyYUOY 9-2-8 2-M 4A 11 2A 11 Jn� CiLREY11::3 Scale=1:23.6 Camber= 1/8 in I1 LOADING (psf. SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plateslncrease 1.25 TC 0.71 Vert(LL) 0.18 D-G >601 240 MT20 244/190 TCDL 7.0 Lumberincrease 1.25 BC 0.39 Vert(TL) -0.23 D-G >468 180 BCLL 0.0 * Rep Stress Incr YES WB 0.00 Horz(TL) 0.02 B n/a n/a BCDL 5.0 1 Code FBC2007/TP12002 (Matrix-M) Weight: 46 lb FT = 20% LUMBER BRACING TOPCHORD 2X6SYPNo.2 TOPCHORD Structural woodsheathing directlyapplied or6-0-0 oc BOT CHORD 2 X 4 SYP No.2 purlins, except end verticals. WEBS 2X4SYPNo.3 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends thatStabil izers and required cross bracing be installed during truss erection, in accordancewithStabilizerinstallation guide. REACTIONS (lb/size) D=228/Mechanical, B=349/0-8-0 Max HorzD=-427(LC 5) Max UpliftD=-438(LC 5), B=-695(LC 5) Max Grav D=270(LC 2), B=418(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD A-D=-216/429,A-B=-801/945 BOT CHORD B-D=-904/747 NOTES 1) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveloads. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrentwith any other live loads. 4) *This truss has been designed for alive load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Pr5vide mechanical connection (by others) of truss to bearing plate capable of withstanding 438 lb uplift atjoint D and 695 lb uplift atjoint E. 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOA6CASE(S) Standard Jbb ► 1 Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 22137 A07 Monopitch Truss 1 1 Job Reference (optional) East Coast Truss, FORT PIERCE, FL. 34946 7.250 s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:21:17 2011 Page 1 ID:ZycEGXaGiSuaivl hsBRj37zPYdX-Vt4ywMFVnWNjp8j F9gliFf65FbmCWmjGvCtGyYUOW 9-2-8 4A 11 Scale=1:22.4 Camber= 1/8 in 418#/-695# 9-2-8 2-" 9-2-8 Plate Offsets (X,Y): fB:0-0-14,0-0-21 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plateslncrease 1.25 TC 0.71 Vert(LL) 0.18 D-G >595 240 MT20 "244/19D TCDL 7.0 Lumberincrease 1.25 BC 0.34 Vert(TL) -0.23 D-G >468 180 BCLL 0.0 * Rep Stress Incr YES WB 0.00 Horz(TL) -0.01 B n/a n/a BCDL 5.0 Code FBC2007ITP12002 (Matrix-M) Weight: 46 lb FT.'= 20% LUMBER BRACING TOP CHORD 2.X 6 SYP No.2 TOP CHORD BOT CHORD 2 X 4 SYP No.2 WEBS 2 X 4 SYP No.3 BOT CHORD REACTIONS (lb/size) D=228/Mechanical, B=349/0-8-0 Max H orzB=427(LC 4) Max UpliftD=-439(LC 4), B=-695(LC 4) Max Grav D=270(LC 2), B=418(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD B-C=-801/954,C-D=-216/429 BOTCHORD B-D=-1157/747 Structural wood sheathing directly applied or6-0-0 oc purlins, except end verticals. Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends thatStabilizers and required cross bracing be installed during truss erection, in acco rda n cewith Stabilizer Instal Iationguide. NOTES 1) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and rightexposed; LumberDOL=1.60 plate grip DOL=1.60 2) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveloads. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrentwith any other live loads. 4) "This truss has been designed fora live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Referto girder(s) fortruss to truss connections. 6) Pratide mechanical connection (by others) of truss to bearing plate capable of withstanding 439 lb upliftatjoint D and 695 lb uplift atjoint E. 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD`CASE(S) Standard Jbb ! truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 'J 22137 A08 CAMBER 1 1 • Job Reference (optional) East Coast Truss, FORT PIERCE, FL. 34946 7.250 s May 112011 MiTek Industries, Inc. Fri Sep 30 10:21:21 2011 Page 1 ID:ZycEGXaG!5uaivlhsBRj37zPYdX OeKTIsLmY?g4rL7vy5DmTYQIOXPiusMeuuPOlyYUOS 7-M 6-0-0 6-0-0 7-M 2-M 3x8 = 2.00 F12 940#1-1389# 4.00 12 5x10 II 2A = 1A II 1A II Scale=1:50.1 Camber= 314 in IA II 3)0 zz 9409/-1389# Plate Offsets(X,Y): [D:0-2-0,0-5-41,[F:0-2-0 0-5-4] [J:0-2-0,0-0-1 21,[J:0-5-4,0-3-41,[K:0-5-4,0-3-4],[K:0-2-0,0-1-1 21 LOADING (pso SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plateslncrease 1.25 TC 0.74 Vert(LL) -0.77 J-K • >407 240 MT26 244/190 TCDL 7.0 i Lumberincrease 1.25 BC 0.67 Vert(TL) -1.51 J-K >207 180 BCLL 0.0 * Rep Stresslncr YES WB 0.49 Horz(TL) -0.28 H n/a n/a BCDL 5.0 Code FBC2007/TPI2002 (Matrix-M) Weight:176 lb FT = 20% LUMBER BRACING TOP CHORD .2 X 6 SYP No.2 TOPCHORD Structural wood sheathing directlyappliedor4-2=2oc BOT CHORD .2X4 SYP No.2 *Except* purlins. B2: 2 X 4 SYP No.1 BOT CHORD Rigid ceiling directly applied or3-3-0 oc bracing. Except: WEBS 2 X 4 SYP No.3 4-10-0 oc bracing: J-K WEBS 1 Row at midpt E-J, E-K MiTek recommends thatStabilizers and required cross bracing be installed during truss erection, in accordancewithStabilizerinstallation guide. REACTIONS (lb/size) B=790/0-8-0, H=790/0-8-0 Max HorzB=211(LC 4) Max UpliftB=-1389(LC 6), H=-1389(LC 7) Max Grav B=940(LC 2), H=940(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD B-C=-3096/3811,C-E=-3057/4046,E-G=-3057/3893,G-H=-3096/3652 BOTCHORD B-K=-3584/2903,J-K=-1745/1579,H-J=-3227/2903 WEBS E-J=-2031/1492,G-J=-230/547,E-K=-2118/1492,C-K=-230/532 NOTES 1) Unbalanced roof live loads have been considered forthis design. 2) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable endzone; cantilever left and rightexposed; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveloads. 4) Thts truss has been designed for a 10.0 psf bottom chord live load nonconcurrentwith any other live loads. 5) * This truss has been designed fora live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any othermembers. 6) Bearing atjoint(s) B, H considers parallel to grain value usingANSI/TPI 1 angle to grain formula. Building designer shduld verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1389lb uplift atjointS and 1389 lb uplift atjointV. 8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. Continued on page 2 Jbb tPi. Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 22137 A08 CAMBER 1 1 Job Reference (optional) East Coast I russ, FUR I PIERCE, FL. 34946 7.Zbu s may 11 zul I mi I eK Inoustnes, Inc. Fri sep 3u l u:zl :zz zul 1 rage z ID:ZycEGXaGi5uaivlhsBRj37zPYdX squrzCMOJJoxTUi6Wol771zVJ6teRL6VsYdzYTyYUOR LOP-0 CASE(S) Standard Job li' Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof r 22137 A09 CAMBER 1 1 Job Reference (optional) East Coast Truss, FORT PIERCE, FL. 34946 7.250 s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:21:35 2011 Page 1 ID:ZycEGXaGi5uaivlhsBRj37zPYdX zKAIhfWYFIR5XUCcm1U21V?j1LHl_EKQs3H9WDyYUCE 2-0-0 7-" 6-0-0 6_0-0 7-M 2-0-0 4.00 12 3Xs = 7x6 = 7X4 II 1A II 3S ZZ Scale=1:50.1 Camber= 3/4 in 2.00 F12 940#/-1389# 940#/-13899 3-0-0 I 20-0-0 3-0-0 Plate Offsets (X Y): [D:0-2-0 0-5-4] [F:0-2-0 0-5-4] [J:0-2-0 0-0-12] [J:0-5-4 0-3-4] [K:0-5-4 0-3-4] [K:0-2-0,0-1-12] LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES- GRIP TCLL 20.0 Plateslncrease 1.25 TC 0.74 Vert(LL) -0.80 J-K >390 240 MT20 244/190 TCDL 7.0 Lumberincrease 1.25 BC 0.79 Vert(TL) -1.57 J-K >199 180 BCLL 0.0 Rep Stress Incr YES WB 0.49 Horz(TL) -0.29 H n/a n/a BCDL 5.0 Code FBC2007ITP12002 (Matrix-M) Weight:168 lb FT = 20% LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD Structural wood sheathing directly applied or4-2-1 oc BOT CHORD 2 X 4 SYP No.2 purlins. WEBS 2 X 4 SYP No.3 BOT CHORD Rigid ceiling directly applied or3-3-0 oc bracing. Except: 4-7-0 oc bracing: J-K WEBS 1 Row atmidpt E-J, E-K MiTek recommends that Stabilizers and required cross bracing be installed duringtruss erection, in accordancewithStabilizerinstallation guide. REACTIONS (lb/size) B=790/0-8-0, H=790/0-8-0 MaxHorzB=211(LC4) Max UpliftB=-1389(LC 6), H=-1389(LC 7) Max Grav B=940(LC 2), H=940(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD B-C=-3097/3812,C-E=-3059/4047,E-G=-3059/3894,G-H=-3097/3653 BOTCHORD B-K=-3585/2904,J-K=-1745/1579,H-J=-3228/2904 WEBS E-J=-2032/1493,G-J=-229/547,E-K=-2119/1493,C-K=-229/532 NOTES 1) Unbalanced roof live loads have been considered forthis design. 2) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveloads. 4) Thrstruss has been designed fora 10.0 psf bottom chord live load nonconcurrentwith any other live loads. 5) *This truss has been designed for alive load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing atjoint(s) B, H considers parallel to grain value usingANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 13891b uplift atjoint U and 1389lb uplift atjointX. 8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. Continued on page 2 Jbb t V Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 22137 A09 CAMBER 1 1 Job Reference (optional) East Goast I russ, I -UK I HILKGL, FL. 34946 r.zou s may i i zui i Ivu I eK Inausines, Inc. rn sep 3u i u:L"I:ae zu-I -I rage z ID:ZycEGXaGi5uaivl hsBRj37zPYdX-RXk8v?XAOcZy8emo4?HZiYunld jhaZ4joi2gyYUOD LOADCASE(S) Standard Jbb ' Truss Truss Type aty Ply 22137-Klein, Ron -Klein Re -Roof 22137 A10 Hip Truss 1 1 Job Reference (optional) East Coast Truss, FORT PIERCE, FL. 34946 2-0-0 5.0-0 7.250 s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:21:39 2011 Page 1 ID:ZycEGXaGi5uaivlhsBRj37zPYdX s6PGXOZ3JXxXO6VN?tY BIAPRyhO% f?mhFMFyYUOA 4-0-0 6-0-0 5x8 = 64 = 5-0-0 12-M Scale=1:51.0 Camber=1/4 in 6 C6 I�Id IS = 3x8 = 2.00 12 940#/-1420# LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl L/d TCLL 20.0 Platesincrease 1.25 TC 0.71 Vert(LL) 0.54 K-L >579 240 TCDL 7.0 Lumberincrease 1'25 BC 0.64 Vert(TL) -0.45 I-J >686 180 BCLL 0.0 " Rep Stress Incr YES WB 0.66 Horz(TL) -0.27 G n/a n/a BCDL 5.0 I Code FBC2007ITP12002 (Matrix-M) LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD BOT CHORD 2 X 4'SYP N0.2 WEBS 2 X 4 SYP No.3 BOT CHORD REACTIONS (lb/size) B=790/0-8-0, G=790/0-8-0 Max HorzB=-188(LC 5) Max UpliftB=-1420(LC 4), G=-1420(LC 5) Max Grav B=940(LC 2), G=940(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD B-C=-3013/3929,C-D=-1849/2378,D-E=-1741/2318,E-F=-183312303, F-G=-3006/3796 BOTCHORD B-L=-3690/2819,K-L=-3580/2723,J-K=-2067/1734,1-J=-3275/2716, G-1=-3375/2813 WEBS C-L=-512/467, C-K=-1006/1540, D-K=-275/283, E-J=-277/283, F-J=-1012/1492, F-1=-462/468 940k/-1420# PLATES GRIP:, MT20 244/190 Weight:147 lb FT'-- 20% Structural wood sheathing directly appliedor4-3-1 oc. purlins. Rigid ceiling directly applied or3-1-12 oc bracing. MiTek recommends thatStabilizers and required cross bracing be installed during truss erection, in accordancewith Stabil izerl nstal lation guide. NOTES 1) Unbalanced roof live loads have been considered forthis design. 2) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveloads. 4) Provide adequate drainage to preventwater ponding. 5) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) "This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-U=0 wide will fit between the bottom chord and any other members. 7) Bearing atjoint(s) B, G considers parallel to grain value usingANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. Continued on page 2 Jbb Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 22137 A10 Hip Truss 1 1 " Job Reference (optional) East coast I russ, I -UK I MERGE, FL. 34946 7.250 s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:21:39 2011 Page 2 ID:ZycEGXaGi5uaivlhsBRj37zPYdX-s6PGXOZ3JXxXO6VN?tY BLAPRyhOw f?mhFMfyYUOA NOTES 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1420 lb uplift atjoint M and 1420 lb uplift atjoint P. 9) "Semi -rigid pitchbreaks including heels" Memberend fixity model was used in the analysis and design of this truss. LOADCASE(S) Standard Job Truss Truss Type city Ply 22137-Klein, Ron -Klein Re -Roof 22137 A11 Hip Truss 1 1 Job Reference (optional) East Coast Truss, FORT PIERCE, FL. 34946 7.250 s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:21:43 2011 Page 1 ID:ZycEGXaGi5uaivlhsBRj37zPYdX ktfnNOcZNIRzUjp8EjdwMBK4Qa3QsvLbhJDaomyYU06 2-M 7-0-0 2-0-0 8-0-0 2-0-0 7-0-0 2-0-0 4.00 12 qa; 6)(8 _ 74 _ 3A F W = 3S ZZ 2.00 12 940#/-1449# Scale=1:51.0 Camber = 1 /4 in Plate Offsets (X Y): [D:0-5-8 0-3-41 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plateslncrease 1.25 TC 0.78 Vert(LL) 0.61 J-K >510 240 MT20 244/190 ._ TCDL 7.0 Lumberincrease 1.25 BC 0.61 Vert(TL) -0.53 J-K >594 180 BCLL 0.0 ` Rep Stresslncr YES WB 0.23 Horz(TL) -0.31 G n/a n/a BCDL 5.0 Code FBC2007/TPI2002 (Matrix-M) Weight:'138lb FT = 20% LUMBER BRACING TOP CHORD 2X6SYPNo.2 TOPCHORD Structural wood sheathing directly applied or4-2-5 oc BOTCHORD 2 X 4`.SYP No.2 purlins, WEBS 2X4'SYPNo.3 BOTCHORD Rigid ceiling directly applied or 3-2-4 oc bracing. MiTek recommends that Stabi lizers and required cross bracing be installed during truss erection, in accordancewithStabilizerinstallation quide. REACTIONS (lb/size) B=790/0-8-0, G=790/0-8-0 MaxHorzB=165(LC4) Max UpliftB=-1449(LC 4), G=-1449(LC 5) Max Grav B=940(LC 2), G=940(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD B-C=-3018/401 0, C-D=-2454/3348, D-E=-2405/3224, E-F=-2467/3269, F-G=-3017/3884 BOTCHORD B-L=-3729/2826,K-L=-3622/2741,J-K=-3044/2390,1-J=-3345/2740, G-1=-3443/2825 WEBS C-L=-563/456, C-K=-463/799, D-K=-444/386, E-J=-376/381, F-J=-446/760, F4=-513/450 NOTES 1) Unbalanced roof live loads have been considered forthis design. 2) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and rightexposed ; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveioads. 4) Provide adequate drainage to preventwater ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrentwith any other live loads. 6) *This truss has been designed for alive load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-G=0 wide will fit between the bottom chord and any other members. 7) Bearing atjoint(s) B, G considers parallel to grain value usingANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. Continued on page 2 Jbb Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 22137 A11 Hip Truss 1 1 Job Reference (optional) East Coast Truss, FORT PIERCE, FL. 34946 7.250 s May 112011 MiTek Industries, Inc. Fri Sep 30 10:21:43 2011 Page 2 ID:ZycEGXaGi5uaivlhsBRj37zPYdX ktfnNOcZNIRzUjpBEjdwMBK4Qa3QsvLbhJDaomyYU06 NOTES 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1449lb uplift atjoint M and 1449 Ib upliftatjoint P. 9) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Jbb Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 22137 Al2G JACK -PARTIAL TRUSS 1 2 j. Job Reference (optional) East Coast Truss, FORT PIERCE, FL. 34946 7.250 s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:21:48 2011 Page 1 ID:ZycEGXaGi5uaiv1hsBRj37zPYdX 5gSgQ5giBl4FbUh61GC53E2?ZbhGX5gKrbwLTzyYU01 2-" 7-" 6-" 6-0-0 7-M 2-" 5x10 MT18H= 4x10 = 4x10 = 2.00 12 1637#/-2580# 1714#/--2717# Scale=1:51.0 Camber= 3/8 in v 1� I d 7-3-0 5-M 5-M 7-M 2-0-0 26 0 2-0-0 Plate Offsets (X,Y):[C:0-5-4,0-2-121,[E:0-5-4,0-2-121 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plateslncrease 1.25 TC 0.56 Vert(LL) 1.17 1 >267 240 MT20 244/190 TCDL 7.0 Lumberincrease 1c25 BC 0.96 Vert(TL) 0.93 1 >334 180 MT18H 244/190 BCLL 0.0 * Rep Stress Incr NO WB 0.55 Horz(TL) -0.49 F n/a n/a BCDL 5.0 Code FBC2007ITP12002 (Matrix-M) Weight: 267lb FT = 20% LUMBER BRACING TOPCHORD 2X6SYP SS TOPCHORD Structural wood sheathing directly applied or5-10-9 oc BOT CHORD 2 X 4 SYP No.2 purlins. WEBS 2 X 4 SYP No.3 BOTCHORD Rigid ceiling directly applied. REACTIONS (lb/size) B=1383/0-8-0, F=1446/0-8-0 MaxHorzB=142(LC4) Max UpliftB=-2580(LC 4), F=-2717(LC 5) Max Grav B=1637(LC 2), F=1714(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD B-C=-6643/9839,C-D=-8714/13218,D-E=-8714/13218,E-F=-7015/10390 BOT CHORD B-J=-9253/6278,1-J=-9431 /6422, H-1=-9920/6780, F-H=-9734/6631 WEBS C-J=-1643/1256, C-1=-3886/2535, D-1=-809/1500, E-1=-3166/2129, E-H=-1712/1310 NOTES 1) 2-ply truss to be connected togetherwith 10d (0.131 "x3") nails as follows: Top chords connected as follows: 2 X 6 - 2 rows at 0-9-0 oc. Bottom chords connected as follows: 2 X 4 -1 row at 0-9-0 oc. Webs connected as follows: 2 X 4 -1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been consideredforthis design. 4) Wiod: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveloads. 6) Provide adequate drainage to preventwaterponding. 7) All plates are MT20 plates unless otherwise indicated. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcu rrent with any other live loads. 9) * This truss has been designed fora live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by CoatPn%didg jAbgt�)etween the bottom chord and any othermembers. Jbb ' Truss Truss Type Qty ; Ply 22137-Klein, Ron -Klein Re -Roof 22137 Al2G JACK -PARTIAL TRUSS 1 2 Job Reference (optional) East Coast Truss, I-URT PIERCE, FL. 34946 7.250 s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:21:49 2011 Page 2 ID:ZycEGXaGi5uaivlhsBRj37zPYdX Z102dRhKybC6CeGIbzkKbSaAJ_1VGYwT4Fgu?PMOO NOTES ` 10j Bearing atjoint(s) B, F considers parallel to grain value usingANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 2580 Ib uplift atjoint K and 2717 lb upliftatjoint N. 12) "Semi -rigid pitchbreaks including heels" Memberend fixity model was used in the analysis and design of this truss. 13)-Ha' nger(s) or other connection device(s) shall be provided sufficientto support concentrated load(s)117 lbdown and 287 lb up at 7-0-0,117 lbdown and 287 Ib up at 9-0-12, 117 lb down and 287 lb up at 11-0-12, 117 lb down and 287 lb up at 13-0-0, 117 lb down and 287 lb up at 14-11-4, and 117 Ib down and 287 Ib up at 16-11-4, and 322 Ib down and 663 Ib up at 19-0-0 on top chord, and 235 Ib down and 192 lb up at 7-3-0, 49 Ib down and 12 lbup at 9-0-12, 49 lb down and 12 lb up at 11-0-12, 49 lb down and 12 lb up at 13-0-0, 49 lb down and 12 lb up at 14-11-4, and 49 lb down and 12 lb up at 16-11-4, and 235 lb down and 192 lb up at 18-9-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASES) Standard 1) Regular: Lumber Increase= 1.25, Plate lncrease=1.25 Uniform Loads (plf) Vert: A-C=44, C-E=-44, E-G=44, J-K=-10, H-J=-10, H-N=-10 Concentrated Loads (lb) Vert: C=-97(F) E=-234(F) J=-1 58(F) 1=-24(F) D=-97(F) H=-158(F) Q=-97(F) R=-97(F) S=-97(F) T=-97(F) U=-24(F) V=-24(F) W=-24(F) X=-24(F) Job Truss Truss Type city Ply 22137-Klein, Ron -Klein Re -Roof 22137 B01 Common Truss 11 1 Job Reference (optional) East Coast Truss, FORT PIERCE, FL. 34946 7.250 s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:21:51 2011 Page 1 ID:ZycEGXaGi5uaivl hsBRj37zPYdX-VP8o27iaUDSgSyQgiOmogtgXJos2kZcmXZ974lyYU0_ 6x6 = 9-0-0 4x4 = 5x5 = 4x4 = 684#/-1057# 2-M Scale=1:36.1 Camber=Ill 6 in 684#/-1057# Ia Plate Offsets MY): [F:0-2-8,0-3-0] LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES , GRIP TCLL 20.0 Plateslncrease 1.25 TC 0.40 Vert(LL) 0.14 F-I >999 240 MT20 244/190 TCDL 7.0 Lumberincrease 1.25 BC 0.37 Vert(TL) -0.15 F-I >999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.09 Horz(TL) -0.02 D n/a n/a BCDL 5.0 Code FBC2007/TPI2002 (Matrix-M) Weight: 86 lb FT = 20% LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc BOTCHORD 2 X 4 SYP No.2 purlins. WEBS 2X4SYP No.3 BOTCHORD Rigid ceiling directly applied or6-1-15ocbracing. MiTek recommends thatStabilizers and required cross bracing be installed duringtruss erection, in accordance with StabiIizerInstal Iation qu de. REACTIONS (lb/size) B=574/0-8-0, D=574/0-8-0 Max Horz B=165(LC 4) Max UpliftB=-1057(LC 6), D=-1057(LC 7) MaxGrav B=684(LC 2), D=684(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD B-C=-996/1146,C-D=-996/1146 BOTCHORD B-F=-1094/884,D-F=-988/884 WEBS C-F=0/268 NOTES 1) Unbalanced roof live loads have been considered forthisdesign. 2) Wind: ASCE 7-05; 150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and rightexposed; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveloads. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrentwith any other live loads. 5) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1057lb uplift atjoint G and 1057 lb uplift atjoint J. 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOADCASE(S) Standard Jbb Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 22137 B02 Common Truss 1 1 Job Reference (optional) East Coast Truss, FORT PIERCE, FL. 34946 4-8-0 7.250 s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:21:54 2011 Page 1 ID:ZycEGXaGi5uaivl hsBRj37zPYdX w_pxh8kTn8gPJP8FOXJvm3K?tlxpCDDXNfgdyYUNx 9-0-0 2-" 66 _ Scale=1:36.1 Camber=1/16 in 1� F Ia Bt B1 3x8 = H 3x6 11 G 5),6_ — 4x4 = 917#/-1738# 488#/-812# 44-0 440 9-0-0 2-0-0 18 0 2-0-0 Plate Offsets (X,Y): [13:0-8-6,0-0-6],[G:0-2-8,0-3-0] LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plateslncrease 1.25 TC 0.35 Vert(LL) 0.16 G-N >999 240 MT20 244/190 TCDL 7.0 Lumberincrease 1.25 BC 0.37 Vert(TL) -0.18 G-N >871 180 BCLL 0.0 * Rep Stress Incr YES WB 0.54 Horz(TL) 0.02 E n/a n/a BCDL 5.0 Code FBC2007/TP12002 (Matrix-M) Weight: 94lb FT=20% LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD BOT CHORD 2 X 4 SYP N0.2 WEBS 2X4-SYPNo.3 BOTCHORD REACTIONS (lb/size) H=770/0-8-0, E=378/0-8-0 Max HorzH=165(LC4) Max UpliftH=-1738(LC 6), E=-812(LC 5) Max Grav H=917(LC 2), E=488(LC 14) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD B-C=-17741746,C-D=-304/427,D-E=-788/930 BOTCHORD B-H=-661/1839,G-H=-661/1679,E-G=-857/719 WEBS C-H=-874/1607,C-G=-1469/906,D-G=-239/566 Structural wood sheathing directly applied or5-7-9 oc purlins. Rigid ceiling directly applied or6-0-0 oc bracing. MiTek recommends thatStabilizers and required cross bracing be installed during truss erection, in accordancewith Stabilizerl nstallation guide. NOTES 1) Unbalanced roof live loads have been consideredforthis design. 2) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and rightexposed; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveloads. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrentwith any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1738lb uplift atjoint H and 812 lb uplift atjoint L. 7) "Semi -rigid pitchbreaks including heels" Memberend fixity model was used in the analysis and design of this truss. LOADCASE(S) Standard Jbb Truss Truss Type city Ply 22137-Klein, Ron -Klein Re -Roof 22137 B03G Hip Truss 1 1 Job Reference (optional) East Coast Truss, FORT PIERCE, FL. 34946 7.250 s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:21:58 2011 Page 1 ID:ZycEGXaGi5uaivlhsBRj37zPYdX om3SWWozrMKgnlS1cMORTLShadCDtiWo88LtpOyYUNt 7-M 2-0-0 Scale=1:36.8 Camber=1/16 in rvA = 34 = 1A 11 3x4 = 3x4 = 3)0 _ 1138#/--1756# 1164#/--1817# 7-M 4-0-0 7-M 2-0-0 18-0-0 2-0-0 Plate Offsets (X,Y): [C:0-5-4,0-2-12] LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plateslncrease 1.25 TC 0.59 Vert(LL) 0.24 G-1 >917 240 MT20 244/190 TCDL 7.0 Lumberincrease 1.25 BC 0.53 Vert(TL) 0.19 G-1 >999 180 BCLL 0.0 " Rep Stress Incr NO WB 0.14 Horz(TL) -0.08 E n/a n/a BCDL 5.0 Code FBC2007/TPI2002 (Matrix-M) Weight: 93lb FT=20% LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD BOTCHORD 2X4SYPNo.2 WEBS 2 X 4 SYP No.3 BOTCHORD REACTIONS (lb/size) B=960/0-8-0, E=982/0-8-0 MaxHorzB=142(LC4) Max UpliftB=-1756(LC 4), E=-1817(LC 7) Max Grav B=1138(LC 2), E=1164(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD B-C=-2428/3354,C-D=-2337/3441,D-E=-2510/3530 BOTCHORD B-1=-3060/2246,G-1=-3073/2263,E-G=-3136/2323 WEBS C-1=-212/432, C-G=-296/219, D-G=-166/419 Structural wood sheathing directly applied or4-10-9 oc purlins. Rigid ceiling directly applied or3-6-8 oc bracing. MiTek recommends thatStabilizers and required cross bracing be installed during truss erection, in accordancewith Stabilizer) nstallation guide. NOTES 1) Unbalanced roof live loads have been considered forthis design. 2) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. 11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and rightexposed; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveloads. 4) Provide adequate drainage to preventwaterponding. 5) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrentwith any other live loads. 6) "This truss has been designed fora live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1756lb uplift atjointJ and 1817 lb uplift atjoint M. 8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. Continued on page 2 J,ob Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 22137 B03G Hip Truss 1 1 Job Reference (optional) East Coast T russ, FLIRT PIERCE, FL. 34946 7.250 s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:21:58 2011 Page 2 ID:ZycEGXaGi5uaivlhsBRj37zPYdX-om3SW WozrMKgnlSlcMORTLShadCDUWo88LtpOyYUNt NOTES 9) lianger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)113 lbdown and 281 lb up at 7-0-0, and 113 lbdown and 281 lb up at 9-0-0, and 234 lb down and 587 lb up at 11-0-0 on top chord, and 265 lb down and 240 lb up at 7-0-0, and 49 lb down and 8 lb up at 9-0-0, and 265 lb down and 240 lb up at 10-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 1 0)In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25,Plate lncrease=1.25 Uniform Loads (plf) Vert: A-C=-44, C-D=-44, D-F=44, J-M=-10 Concentrated Loads (lb) Vert: C=-94(B) D=-192(B) H=-23(B)1=-195(8) G=-195(B) P=-94(B) Jbb Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 22137 B04G Hip Truss 1 1 Job Reference (optional) East Coast Truss, FORT PIERCE, FL. 34946 7.250 s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:22:03 2011 Page 1 ID:ZycEGXaGi5uaivlhsBRj37zPYdX 9jsLaDr6fvz7uoL_Pw_rAO9byew8YrhXIQ3eUbyYUNo 2-M 4-8-0 2-" 4-0-0 2-" 448-0 2-0-0 5AB = Jµ 3S II 3x4 = WO = 1A II 3x4 = 875#/-2816# 675#/-1343# Scale=1:36.8 2-M 18-M 2-M Plate Offsets (X,Y): [B:0-6-6,0-0-6], [D:0-5-4,0-2-12], [G:0-1-12,0-1-8] LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plateslncrease 1.25 TC 0.42 Vert(LL) 0.08 I-J >999 240 MT20 244/190 TCDL 7.0 Lumberincrease 1.25 BC 0.48 Vert(TL) 0.08 I-J >999 180 BCLL 0.0 " Rep Stress Incr NO WB 0.65 Horz(TL) -0.02 G n/a n/a BCDL 5.0 Code FBC2007/TPI2002 (Matrix-M) Weight:105 lb FT = 20% LUMBER BRACING TOPCHORD 2X6SYPNo.2 TOPCHORD Structural wood sheathing directly applied or5-7-13 oc BOTCHORD 2 X 4 SYP No.2 purlins. WEBS 2X4SYPNo.3 BOTCHORD Rigid ceiling directly applied or4-6-12 oc bracing. MiTek recommends thatStabilizers and required cross bracing be installed during truss erection, in accordance with Stabi I ize r Instal I ation guide. REACTIONS (lb/size) M=658/0-8-0, G=502/0-8-0 MaxHorzM=142(LC4) Max UpliftM=-2816(LC 4), G=-1343(LC 5) Max Grav M=875(LC 2), G=675(LC 14) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD B-C=-17391739,C-D=-166/1265,D-E=-928/2091,E-F=-996/2158, F-G=-1166/2233 BOTCHORD B-M=-655/1806,L-M=-655/1668,J-L=-955/107,1-J=-1890/1066, G-1=-1890/1066 WEBS C-M=-822/2613, C-L=-2388/671, D-L=-919/1055, D-J=- i 333/1083, E-J=-260/417 NOTES 1) Unbalanced roof live loads have been considered forthis design. 2) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat.11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveloads. 4) Provide adequate drainage to preventwaterponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) "This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0"-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 2816 lb uplift atjointM and 1343 lb uplift at joint Q. 8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. Continued on page 2 Jbb Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 22137 B04G Hip Truss 1 1 Job Reference (optional) Last COast I russ, FUR I FIERCE, FL. 34946 7.250 s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:22:03 2011 Page 2 ID:ZycEGXaGiSuaivlhsBRj37zPYdX 9jsLaDr6fvz7uoL Pw cAO9byew8YrhXIQ3eUbyYUNo NOTES 9) Hanger(s) orotherconnection device(s) shall be provided sufficient to support concentrated load(s)113 lbdown and 281 lb up at 7-0-0, and 113lb down and 281 lb up at 9-0-0, and 274 lb down and 587 lb up at 11-0-0 on top chord, and 592 lb up at 7-0-0, and 49 lb down and 8 lb up at 9-0-0, and 265 lb down and 240 Ib up at 10-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 1 0)In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOADCASE(S) Standard 1) Regular: Lumberincrease=1.25,Plate lncrease=1.25 Uniform Loads (plf) Vert:A-D=-44, D-E=-44, E-H=-44, N-Q=-10 Concentrated Loads (lb) Vert: D=-94(F) E=-192(F) K=-23(F) L=587(F) J=-195(F) T=-94(F) Job Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 22137 C01 Half Hip Truss 1 1 Job Reference (optional) East Coast I russ, FUR r PIERCE, FL. 34946 2-M 666#/-1073# IIA II 7.250 s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:22:06 2011 Page 1 ID:ZycEGXaG!5uaiv1hsBRj37zPYdX ZIYTCFu?ygUIF3Z42XJnln8Qr__CIFh_OHISwyYUNI 5-3.8 5-8-0 5)0 _ 3x4 = Scale=1:33.3 2x4 II 6x6 = 542#1-814# Plate Offsets (X,Y): [B:0-1-0,0-1-8],[D:0-5-4,0-2-12] LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plateslncrease 1.25 TC 0.28 Vert(LL) 0.15 G-I >999 240 MT20 244/190 TCDL 7.0 Lumberincrease T.25 BC 0.27 Vert(TL) 0.12 G-1 >999 180 BCLL 0.0 * Rep Stress Incr YES WB 0.51 Horz(TL) -0.05 F n/a n/a - BCDL 5.0 Code FBC2007/TPI2002 (Matrix-M) Weight: 99lb FT=20% LUMBER BRACING TOPCHORD 2X6SYPNo.2 TOPCHORD Structural wood sheathing directlyapplied or6-0-0 oc BOTCHORD 2 X 4 SYP No.2 purlins, except end verticals. WEBS 2X4SYPNo.3 BOTCHORD Rigid ceiling directly applied or4-6-0 oc bracing. MiTek recommends thatStabilizers and required cross bracing be installed during truss erection, in accordancewith Stabilized nstallation guide. REACTIONS (lb/size) B=559/0-8-0, F=457/0-8-0 Max HorzB=391(LC 4) Max UpliftB=-1079(LC 4), F=-814(LC 4) Max Grav B=666(LC 2), F=542(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD B-C=-1352/1802,C-D=-747/1010,E-F=-144/260 BOTCHORD B-1=-1957/1279,G-1=-1957/1279,F-G=-1060/703 WEBS C-G=-616/978,D-G=-262/307,D-F=-784/1185 NOTES 1) Unbalanced roof live loads have been considered forthis design. 2) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat.11; Exp C; enclosed; MWFRS (low-rise) gable end zone; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveloads. 4) Provide adequate drainage to preventwaterponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrentwith any other live loads. 6) * T--)is truss has been designed fora live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1079lb uplift atjoint J and 814 lb uplift atjoint F. 8) "Semi -rigid pitchbreaks including heels" Memberend fixity model was used in the analysis and design of this truss. LOADCASE(S) Standard Jbb Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 22137 CO2 Half Hip Truss 1 1 Job Reference (optional) East Coast Truss, FORT PIERCE, FL. 34946 2-0-0 i 7.250 s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:22:08 2011 Page 1 ID:ZycEGXaGiSuaivlhsBRj37zPYdX-WhgEdxvFURbP ZDyCTZnsStQifemOBDGRimP9pyYUNj 6)B = Scale=1:33.3 Camber=l/6 in 3x4 II 4x4 = E 5x5 = 3x4 = 669#/-1092# 539#/-801 # 2-M i17-4-0 Plate Offsets MY): [C:0-5-4 0-3-12] [F:0-2-8 0-0-41 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plateslncrease 1.25 TC 0.48 Vert(LL) 0.25 G-J >840 240 MT20 244/190 TCDL 7.0 Lumberincrease 1.25 BC 0.39 Vert(TL) -0.24 G-J >849 180 BCLL 0.0 " Rep Stress Incr YES WB 0.38 Horz(TL) -0.04 E n/a n/a BCDL 5.0 Code FBC2007/TP12002 (Matrix-M) Weight: 89 lb FT = 20% LUMBER BRACING TOP CHORD 2X6SYPNo.2 TOPCHORD Structural wood sheathing directly applied or6-0-0 oc BOTCHORD 2X4SYPNo.2 purlins, except end verticals. WEBS 2 X 4 SYP No.3 BOTCHORD Rigid ceiling directly applied or4-9-7 oc bracing. WEBS 1 Row atmidpt C-E MiTek recommends thatStabilizers and required cross bracing be installed during truss erection, in accordancewithStabilizerinstallation uide. REACTIONS (lb/size) B=561/0-8-0, E=455/0-8-0 Max HorzB=337(LC 4) Max UpliftB=-1092(LC 4), E=-801(LC 4) Max Grav B=669(LC 2), E=539(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD B-C=-1161/1492,D-E=-199/351 BOTCHORD B-G=-1488/999,E-G=-1486/1005 WEBS C-G=0/271,C-E=-1019/1513 NOTES 1) Unbalanced roof live loads have been consideredforthis design. 2) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveloads. 4) Provide adequate drainage to preventwaterponding. 5) Thi's truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1092lb uplift atjoint H and 801 lb uplift atjoint E. 8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Jbb Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 22137 CO3 Common Truss 5 1 Job Reference (optional) East Coast Truss, FORT PIERCE, FL. 34946 7.250 s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:22:11 2011 Page 1 ID:ZycEGXaGi5uaivl hsBRj37zPYdX-wGLMFyy7nW_rOyWtb7UU4Vw4shtQcdj7g13m8yYUNg 2-M 8-8-0 8-8-0 6x6 = 3.00 i 12 4x4 = 5x5 = 4x4 = 668#/--1038# 8-8-0 17.4-0 8-8-0 ' 2-0-0 Plate Offsets MY): rE:0-2-8,0-3-01 Scale: 3/8"=1' Camber=1/16 in Id 549#/--732# LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plateslncrease 1.25 TC 0.54 Vert(LL) 0.19 E-H >999 240 MT20 244/190 TCDL 7.0 Lumberincrease 1.25 BC 0.36 Vert(TL) -0.16 E-H >999 180 BCLL 0.0 " Rep Stress Incr YES WB 0.08 Horz(TL) -0.03 D n/a n/a BCDL 5.0 Code FBC2007/TP12002 (Matrix-M) Weight: 76 lb FT = 20% LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD BOT CHORD 2 X 4 SYP No.2 WEBS 2 X 4 SYP No.3 BOT CHORD REACTIONS (lb/size) D=463/0-8-0, B=561/0-8-0 MaxHorz B=159(LC4) Max UpliftD=-732(LC 7), B=-1038(LC 6) Max Grav D=549(LC 2), B=668(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD B-C=-1202/1450,C-D=-1200/1554 BOTCHORD B-E=-1266/1133,D-E=-1337/1133 WEBS C-E=-1/250 Structural wood sheathing directly applied or6-0-0 oc purlins. Rigid ceiling directly applied or5-2-10 ocbracing. MiTek recommends thatStabilizers and required cross bracing be installed during truss erection, in accordancewith Stabilizer) nstallation guide. NOTES 1) Unbalanced roof live loads have been consideredforthis design. 2) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable endzone; cantileverleft and rightexposed; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveloads. 4) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrentwith any other live loads. 5) *This truss has been designed fora live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any othermembers. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 732 lb uplift atjoint F and 1038 lb uplift atjoint I. 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard J5b • Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 22137 C04G Hip Truss 1 1 Job Reference (optional) East Coast Truss, FORT PIERCE, FL. 34946 2-" 7.250 s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:22:15 2011 Page 1 ID:ZycEGXaGi5uaiv1hsBRj37zPYdX olbt5K7egbTQKeF16RBQWaSTzIMPvl2lzGvvyYUNc 3-4-0 7-0-0 2-" 3x8 = 1A 11 5x5 = 10 = 10B7#/-1644# 1112#/--1676# Scale=1:35.6 Camber= 118 in N N Id 7-M 3-4-0 7-M 22-M 17 4 0 2-M Plate Offsets (X Y): [C:0-5-4,0-2-1 21,[G:0-2-8,0-3-01 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plateslncrease 1.25 TC 0.64 Vert(LL) 0.32 G-H >649 240 MT20 244/190 TCDL 7.0 Lumberincrease 1.25 BC 0.65 Vert(TL) 0.25 G-H >830 180 BCLL 0.0 ` Rep Stress Incr NO WB 0.13 Horz(TL) -0.09 E n/a n/a BCDL 5.0 Code FBC2007/TP12002 (Matrix-M) Weight: 87 lb FT = 20% LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD Structuralwood sheathing directlyapplied or4-4-15 oc BOT CHORD 2 X 4 SYP No.2 purlins. WEBS 2 X 4 SYP No.3 BOT CHORD Rigid ceiling directly applied or3-2-0 oc bracing. MiTek recommends thatStabilizers and required cross bracing be installed duringtruss erection, in accordancewith Stabilized ristallation guide. REACTIONS (lb/size) B=918/0-8-0, E=938/0-8-0 MaxHorzB=116(LC4) Max UpliftB=-1644(LC4), E=-1676(LC7) Max Grav B=1087(LC 2), E=1112(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD B-C=-2853/3810,C-D=-2844/3871,D-E=-2941/3923 BOTCHORD B-H=-3610/2723,G-H=-3621/2741,E-G=-3680/2809 WEBS C-H=-141/380,C-G=-314/267,D-G=-109/394 NOTES 1) Unbalanced roof live loads have been consideredforthis design. 2) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. 11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveloads. 4) Provide adequate drainage to preventwaterponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) "•This truss has been designed for alive load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1644lb uplift atjoint I and 1676 lb uplift atjoint L. 8) "Semi -rigid pitchbreaks including heels" Memberend fixity model was used in the analysis and design of this truss. Continued on page 2 Job Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 22137 C04G Hip Truss 1 1 1 Job Reference (optional) Edsi Cudbi i iubb, rum i FICKLE, FL. 34u46 i.Zbu s May 11 2u11 MiTek Industries, Inc. Fri Sep 30 10:22:15 2011 Page 2 • ID:ZycEGXaGi5uaivlhsBRj37zPYdX-olbt5K?egbTQKeF16RBQfwfaSTzIMPvl2lzGvvyYUNc NOTES 9) I' anger(s) or other connection device(s) shall be provided sufficientto support concentrated load(s)113 lb down and 262 lb up at 7-0-0, and 113 lb down and 262 lb up at 8-8-0, and 268 lb down and 541 lb up at 10-4-0 on top chord, and 259 lb down and 185 lb up at 7-0-0, and 47 lb down and 9 lb up at 8-8-0, and 259 lb down and 185 lb up at 10-3-4 on bottom chord. The"design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumberincrease=1.25,Plate lncrease=1.25 Uniform Loads (plf) Vert: A-C=-44, C-D=-44, D-F=-44, I-L=-10 Concentrated Loads (lb) Vert: C=-94(B) D=-187(B) H=-173(B) G=-23(B) 0=-94(B) P=-23(B) Q=-150(B) Job Truss Truss Type city Ply 22137-Klein, Ron -Klein Re -Roof 22137 D01 Monopitch Truss 3 1 Job Reference (optional) East coast I russ, FUR I PIERCE, FL. 34946 7.250 s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:22:17 2011 Page 1 ' ID:ZycEGXaGi5uaivlhsBRj37zPYdX IQieW00umg8ZxPgEsEukUlRHmmgEpbWcSN_nyYUNa 5-11-0 Scale=1:24.9 3x4 = 7x6 = D K I� 3x4 = IA 11 3x4 = 518#/-851# i 6-8-8 370#/-575# 5-11-0 2-" 12-7-8 Plate Offsets MY): [13:0-040-1-8] LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plateslncrease 1.25 TC 0.23 Vert(LL) 0.08 F-J >999 240 MT20 244/190 TCDL 7.0 Lumberincrease 1.25 BC 0.21 Vert(TL) -0.06 F-J >999 180 BCLL 0.0 * Rep Stresslncr YES WB 0.42 Horz(TL) -0.02 K n/a n/a BCDL 5.0 Code FBC2007/fP12002 (Matrix-M) Weight: 72lb FT=20% LUMBER BRACING TOPCHORD 2X6SYPNo.2 TOPCHORD Structural wood sheathing directly applied or6-0-0 oc BOTCHORD 2X4SYPNo.2 purlins, except end verticals. WEBS 2 X 4 SYP No.3 BOTCHORD Rigid ceiling directly applied or5-10-9 ocbracing. OTHERS 2X4SYPNo.3 MiTek recommends that Stabilizers andrequired cross bracing be installed duringtruss erection, in accordancewithStabilizerinstallation uide. REACTIONS (lb/size) B=433/0-8-0, K=313/0-3-8 Max HorzB=405(LC 4) Max U pliftB=-851 (LC 4), K=-575(LC 4) Max Grav B=518(LC 2), K=370(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD B-C=-794/952, E-G=-340/253, D-G=-340/253 BOTCHORD B-F=-1149/747,E-F=-1149/747 WEBS C-E=-726/1118 NOTES 1) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable endzone; cantileverleft and rightexposed; LumberDOL=1.60 plate grip DOL=1.60 2) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveloads. 3) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed fora live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Bearing atjoint(s)Kconsiders parallel tograin value usingANSI/TPI1 angleto grain formula. Building designershould verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 851 lb upliftatjoint H and 575 lb uplift atjoint K. 7) "Semi -rigid pitchbreaks including heels" Memberend fixity model was used in the analysis and design of this truss. LOADCASE(S) Standard Job Truss Truss Type city Ply 22137-Klein, Ron -Klein Re -Roof 22137 D02 Half Hip Truss 1 1 Job Reference (optional) Last coast I russ, t-UK I F'ILRUE, FL. 34946 a M = 3.00 F12 7.250 s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:22:20 2011 Page 1 ID:ZycEGXaGi5uaivl hsBRj37zPYdX-9_Om813nf76jQP8Fv_nbM_MUsUill df1 Cagla6yYUNX 5x10 = Scale=1:25.3 Camber = 3/16 in 3x4 = D Us I I IA II 3x4= K I� 524#/-869# 364#/-557# 11-0-0 1-7-8 ' 2-0-0 12-7-B Plate Offsets (X,Y):[B:0-2-4,0-0-2],[C:0-5-8,0-2-12] LOADING (psf) SPACING - 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plateslncrease 1.25 TC 0.47 Vert(LL) 0.32 F-J >468 240 MT20 244/190 TCDL 7.0 Lumberincrease 1.25 BC 0.57 Vert(TL) -0.36 F-J >415 180 BCLL 0.0 * Rep Stress Incr YES WB 0.29 Horz(TL) -0.02 B n/a n/a BCDL 5.0 Code FBC2007/TPI2002 (Matrix-M) Weight: 68 lb FT = 20% LUMBER BRACING TOPCHORD 2X6SYPNo.2 TOPCHORD Structural wood sheathing directlyappliedor6-0-0oc BOTCHORD 2X4SYPNo.2 purlins, except end verticals. WEBS 2 X 4 SYP No.3 BOTCHORD Rigid ceiling directly applied or7-7-5 ocbracing. OTHERS 2X4SYPNo.3 M iTek recommends that Stabi I izers and required cross bracing be installed duringtruss erection, in accordancewithStabilizerinstallation guide. REACTIONS (Ib/size) B=439/0-8-0, K=307/0-3-8 Max Horz B=373(LC 4) Max UpliftB=-869(LC 4), K=-557(LC 4) Max Grav B=524(LC 2), K=364(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD B-C=-1222/1603,E-G=-1006/611,D-G=-1006/611 BOTCHORD B-F=-1606/1068,E-F=-5081352 WEBS C-F=-49/447,C-E=-801/1140 NOTES 1) Unbalanced roof live loads have been considered forthis design. 2) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveloads. 4) Provide adequate drainage to preventwaterponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for alive load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing atjoint(s) K considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 869 lb uplift atjoint H and 557 lb uplift atjoint K. 9) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASES) Standard Job Truss Truss Type Qty , Ply 22137-Klein, Ron -Klein Re -Roof 22137 D03 Half Hip Truss 1 1 Job Reference (optional) East Coast Truss, FORT PIERCE, FL. 34946 7.250 s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:22:22 2011 Page 1 - ID:ZycEGXaGi5uaivlhsBRj37zPYdX 5NVWVZj41BkMQgjHe0Pp3RPSsCIRhVYFKf 8f?yYUNV a 9-0-0 5)0 _ Scale=1:25:3 Camber=1/16 in 4A = 1A 11 3x4 = 521#/-874# K I� 367#/--552# Plate Offsets MY): [C:0-5-4,0-3-4] LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plateslncrease 1.25 TC 0.35 Vert(LL) 0.16 F-J >950 240 MT20 244/190 TCDL 7.0 Lumberincrease 1.25 BC 0.35 Vert(TL) -0.18 F-J >831 180 BCLL 0.0 Rep Stress Incr YES WB 0.22 Horz(TL) -0.02 K n/a n/a BCDL 5.0 Code FBC2007/TP12002 (Matrix-M) Weight: 67lb FT = 20% LUMBER BRACING TOPCHORD 2X6SYP No.2 TOPCHORD Structural wood sheathing directly applied or6-0-0 oc BOTCHORD 2 X 4 SYP No.2 purlins, except end verticals. WEBS 2 X 4 SYP No.3 BOTCHORD Rigid ceiling directly applied or6-8-13 ocbracing. OTHERS 2X4SYP No.3 MiTek recommends thatStabilizers and required cross bracing be installed during truss erection, in accordancewithStabilizerinstallation uide. REACTIONS (lb/size) B=436/0-8-0, K=310/0-3-8 Max HorzB=319(LC 6) Max UpliftB=-874(LC 4), K=-552(LC 4) Max Grav B=521(LC 2), K=367(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD B-C=-809/951, E-G=-497/340, D-G=-497/340 BOTCHORD B-F=-968/688,E-F=-761/516 WEBS C-E=-588/861 NOTES 1) Unbalanced roof live loads have been consideredforthis design. 2) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable endzone; cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveloads. 4) Provide adequate drainage to preventwaterponding. 5) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrentwith any other live loads. 6) * Tdiis truss has been designed fora live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing atjoint(s) K considers parallel to grain value usingANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 874lb uplift atjoint H and 552 lb uplift atjoint K. 9) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOADCASE(S) Standard J'0b Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 22137 D04G Half Hip Truss 1 1 Job Reference (optional) Iasi toast I russ, rvK I mtKL;t, i-L. J494[i 7.25U s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:22:25 2011 Page 1 ID:ZycEGXaGi5uaivlhsBRj37zPYdX WyBfBl7vUfk?XAODiXNm314LHVSLipbnLrOoGKyYUNS 3A= 1A 11 34= 706#/-11309 , 7-M 5-7-B 2-0-0 12-7-8 Plate Offsets (X,Y):[B:0-1-4,0-1-81,[C:0-5-4,0-2-121 Scale=1:25.3 768#/-11069 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plateslncrease 1.25 TC 0.43 Vert(LL) 0.12 F-J >999 240 MT20 244/190 TCDL 7.0 Lumberincrease 1.25 BC 0.35 Vert(TL) -0.09 F-J >999 180 _ BCLL 0.0 * Rep Stresslncr NO WB 0.62 Horz(TL) -0.04 K n/a n/a BCDL 5.0 Code FBC2007/TP12002 (Matrix-M) Weight: 67lb FT = 20% LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD Structural wood sheathing directly applied or6-0-0 oc BOT CHORD 2X4SYP No.2 purlins, except end verticals. WEBS 2 X 4 SYP No.3 BOT CHORD Rigid ceiling directly applied or4-6-0 oc bracing. OTHERS 2X4SYP No.3 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordancewithStabilizerinstallation uide. REACTIONS (lb/size) B=595/0-8-0, K=652/0-3-8 Max HorzB=265(LC 4) Max UpliftB=-1130(LC 4), K=-1106(LC 4) Max Grav B=706(LC 2), K=768(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less exceptwhen shown. TOP CHORD B-C=-1454/1910, C-D=-225/325, E-G=-597/483, D-G=-597/483 BOTCHORD B-F=-1927/1373,E-F=-1937/1394 WEBS C-F=-139/474,C-E=-1243/1713 NOTES 1) Unbalanced roof live loads have been consideredforthis design. 2) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. 11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveloads. 4) Provide adequate drain age to prevent water po ndi ng. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) *This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing atjoint(s) K considers parallel to grain value using ANS I/TPI 1 angle to grain formula. Building designershould verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 11301b upliftatjoint H and 1106 lb uplift atjoint K. 9) "Semi -rigid pitch breaks including heels" Member end fixity model was used in the analysis and design of this truss. Continued on page 2 Job Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 22137 D04G Half Hip Truss 1 1 Job Reference (optional) Last uoasi i russ, f-uK i PILKCL, I-L. 34U46 1.25U s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:22:25 2011 Page 2 ID:ZycEGXaGi5uaivlhsBRj37zPYdX WyBfBl7vUfk7XAODiXNm314LHVSl.ipbnLrOoGKyYUNS NOTES 10rHanger(s) or other connection device(s) shall be provided sufficientto support concentrated load(s)113 lb down and 262 lb up at 7-0-0, and 113 lb down and 262 lb up at 9-0-12, and 113 lb down and 262 lb up at 11-0-12 on top chord, and 259 lb down and 185 lb up at 7-0-0, and 47 lb down and 9 lb up at 9-0-12, and 47 lb down and 9 lb up at 11-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumberincrease=1.25, Plate lncrease=1.25 Uniform Loads (plf) Vert:A-C=-44, C-D=-44, E-H=-10 Concentrated Loads (lb) Vert: F=-173(B) C=-94(B) L=-94(B) M=-94(B) N=-23(B) 0=-23(B) Job Truss Truss Type QtY PIY 22137-Klein, Ron -Klein Re -Roof 22137 E01 Common Truss 4 1 Job Reference (optional) East Coast Truss, FORT PIERCE, FL. 34946 7.250 s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:22:29 2011 Page 1 ID:ZycEGXaGi5uaivlhsBRj37zPYdXOjRA16AQXuER7nK )NSjDtE316p2ej4MGTM0P5yYUN0 , 2-M ' 6-9-8 5-8-8 5-8-8 6-9-8 2-0-0 5x5 = 3.00 12 4x4 = 3x4 = 3x4 = 3x4 = 4x4 = 90B#/-10349 Scale: 1/4"=V Camber= 1/8 in I� 908#/-1034# 8-8-5 7-7-5 B-8-5 2-M 25-0-0 2-M LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud TCLL 20.0 Plateslncrease 1.25 TC 0.32 Vert(LL) 0.26 H-J >999 240 TCDL 7.0 Lumberincrease 1.25 BC 0.43 Vert(TL) -0.29 H-J >999 180 BCLL 0.0 * Rep Stress Incr YES WB 0.21 Horz(TL) 0.07 F n/a n/a BCDL 5.0 Code FBC2007/TP12002 (Matrix-M) LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD BOT CHORD 2 X 4 SYP No.2 WEBS 2 X 4 SYP No.3 BOT CHORD REACTIONS (lb/size) B=763/0-8-0, F=763/0-8-0 MaxHorz B=134(LC4) Max UpliftB=-1034(LC 6), F=-1034(LC 7) Max Grav B=908(LC 2), F=908(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD B-C=-2234/2167,C-D=-1956/1852,D-E=-1956/1853,E-F=-2234/2168 BOTCHORD B-J=-2068/2130,H-J=-1296/1515,F-H=-1952/2130 WEBS D-H=-463/490, E-H=-381/552, D-J=-462/490, C-J=-381 /551 PLATES GRIP MT20 244/190 Weight:129 lb FT = 20% Structural wood sheathing directly applied or5-2-9 oc purlins. Rigid ceiling directly applied or4-4-9 oc bracing. MiTek recommends thatStabilizers and required cross bracing be installed during truss erection, in accordancewith Stabilizer) nstallation guide. NOTES 1) Unbalanced roof live loads have been consideredforthisdesign. 2) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat.11; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveloads. 4) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrentwith any other live loads. 5) `This truss has been designed for alive load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1034lb uplift atjoint K and 1034 lb uplift atjoint N. 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Job Truss Truss Type Qtv Plv 22137-Klein, Ron -Klein Re -Roof 22137 E02 Hip Truss 1 1 Job Reference (optional) East Coast I russ, FORT PIERCE, FL. 34946 7.250 s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:22:32 2011 Page 1 ID:ZycEGXaGi5uaivl hsBRj37zPYdX-pl6lf8CIgpcOsF2ZcV?QrWsY?KoZr36pyRagOQyYUNL 2-0-0 6-M 4-11-8 3-0-0 4-11-8 6-0-8 2-M 6x6 = 5X8 _ 3.00 12 3S 5x8 = 3A = 10 = 908#/-1043# Scale:l/4"=1' Camber = 3/16 in 908#/-1043# N Nt A to 5 d 2-0-0 25-0-0 2-M Plate Offsets MY): [E:0-5-4,0-2-12] [J:0-2-12,0-3-0] LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plateslncrease 1.25 TC 0.40 Vert(LL) 0.25 I-J >999 240 MT20 244/190 TCDL 7.0 Lumberincrease 1.25 BC 0.57 Vert(TL) -0.43 I-P >692 180 BCLL 0.0 * Rep Stress Incr YES WB 0.25 Horz(TL) 0.08 G n/a n/a BCDL 5.0 Code FBC2007frP12002 (Matrix-M) Weight: 136lb FT = 20% LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD Structural wood sheathing directly applied ors-2-1 oc BOT CHORD 2 X 4 SYP No.2 purlins. WEBS 2 X 4 SYP No.3 BOT CHORD Rigid ceiling directly applied or4-3-15 oc bracing. MiTek recommends that Stabi I izers and required cross bracing be installed during truss erection, in accordancewithStabilizerinstallation guide. REACTIONS (lb/size) B=763/0-8-0, G=763/0-8-0 MaxHorzB=122(LC4) Max UpliftB=-1043(LC 4), G=-1043(LC 5) Max Grav B=908(LC 2), G=908(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD B-C=-2223/2214,C-D=-1776/1681,D-E=-1700/1688,E-F=-1765/1672, F-G=-2222/2217 BOTCHORD B-J=-2120/2122,1-J=-1424/1699,G-1=-2000/2121 WEBS C-J=-476/645,F4=-484/655 NOTES 1) Unbalanced roof live loads have been considered forthis design. 2) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable endzone; cantileverleft and rightexposed; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveloads. 4) Provide adequate drainage to preventwaterponding. 5) TNs truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) *This truss has been designed fora live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1043lb uplift atjoint K and 1043 lb uplift atjoint N. 8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOADCASE(S) Standard Job Truss Truss Type aty Ply 22137-Klein, Ron -Klein Re -Roof 22137 E03 Hip Truss 1 1 Job Reference (optional) East coast Truss, FORT PIERCE, FL. 34946 9-M 3.00 12 5)0 = 7.250 s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:22:35 2011 Page 1 ID:ZycEGXaGi5uaivlhsBRj37zPYdX DtoRHAEB7k?akin8HeY7T8U3FXsH2QcFfPpKdyYUNI 64 = 2-M Scale:l/4"=1' Camber = 118 in ob N N I� 4x4 = 1x4 11 3x4 = 3x4 = 4x4 = 908#/-1069# LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud TCLL 20.0 Plateslncrease 1.25 TC 0.40 Vert(LL) 0.24 1 >999 240 TCDL 7.0 Lumberincrease 1.25 BC 0.44 Vert(TL) -0.26 I-L >999 180 BCLL 0.0 4 Rep Stress Incr YES WB 0.21 Horz(TL) -0.07 E n/a n/a BCDL 5.0 Code FBC2007/TPI2002 (Matrix-M) LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD BOT CHORD 2 X 4 SYP No.2 WEBS 2 X 4 SYP No.3 BOT CHORD REACTIONS (lb/size) B=763/0-8-0, E=763/0-8-0 MaxHorzB=107(LC4) Max UpliftB=-1069(LC 4), E=-1069(LC 5) Max Grav B=908(LC 2), E=908(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD B-C=-2051/2038,C-D=-1950/2052,D-E=-2056/2042 BOTCHORD B-1=-1907/1940,G-1=-1905/1945,E-G=-1804/1945 908#/-1069# PLATES GRIP MT20 244/190 Weight:123 lb FT = 20% Structural wood sheathing directly applied or 5-2-4 oc purlins. Rigid ceiling directly applied or4-5-4 oc bracing. MiTek recommends thatStabilizers and required cross bracing be installed during truss erection, in accordancewith Stabilizerl nstallation gu ide. NOTES 1) Unbalanced roof live loads have been consideredforthis design. 2) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and rightexposed; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveloads. 4) Provide adequate drainage to preventwaterponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) "This truss has been designed for alive load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1069lb uplift atjointJ and 1069 lb uplift atjoint M. 8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 22137 E04G Hip Truss 1 1 • Job Reference (optional) East Coast Truss, FORT PIERCE, FL. 34946 d p 4x12 = 1595#/-2149# 7-0-0 7.250 s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:22:40 2011 Page 1 ID:ZycEGXaGi5uaivl hsBRj37zPYdX-arbKLUKyGdtgUg54B819CBrfYSzjcu_ohWSlyyYUND 5-6-0 5-6-0 7-M 2-0-0 5x10 MT18H= 1x4 11 3x10 MT18H= 4)B = W 1x4 II Scale:l/4"=1' Camber= 3/8 in a N N I� 4x12 = 1646#/-2261 # Plate Offsets MY): jC:0-6-8,0-3-4jjE:0-6-8,0-3-4j LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plateslncrease 1.25 TC 0.67 Vert(LL) 0.94 1 >320 240 MT20 244/190 TCDL 7.0 Lumberincrease 1.25 BC 0.86 Vert(TL) 0.73 1 >411 180 MT18H 244/190 BCLL 0.0 * Rep Stresslncr NO WB 0.52 Horz(TL) -0.22 F n/a n/a BCDL 5.0 Code FBC2007/TPI2002 (Matrix-M) Weight: 129lb FT = 20% LUMBER BRACING TOP CHORD 2 X 6 SYP SS TOP CHORD Structural wood sheathing directly applied or 3-2-5 oc BOTCHORD 2 X 4 SYP No.1 purlins. WEBS 2X4SYP No.3 BOTCHORD Rigid ceiling directly applied or2-4-13 oc bracing. WEBS 1 Row at midpt C-1, E-1 MiTek recommends thatStabilizers and required cross bracing be installed duringtruss erection, in accordancewith Stabilized ristallation guide. REACTIONS (lb/size) B=1348/0-8-0, F=1389/0-8-0 MaxHorzB=92(LC 4) Max UpliftB=-2149(LC 4), F=-2261(LC 7) Max Grav B=1595(LC 2), F=1646(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOPCHORD B-C=-4771/6248,C-D=-6002/8159,D-E=-6002/8159,E-F=-4957/6651 BOTCHORD B-K=-5979/4576,1-K=-5988/4595,H-1=-6283/4774,F-H=-6275/4755 WEBS C-K=-112/446,C-1=-2341/1632,D-1=-749/1293,E-1=-1948/1443, E-H=-105/445 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. 11; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and rightexposed ; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveloads. 4) Provide adequate drainage to preventwaterponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any othermembers. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 2149 lb uplift atjoint L and 2261 lb uplift atjoint O. 9) "Semi -rigid pitchbreaks including heels" Memberend fixity model was used in the analysis and design of this truss. Continued on page 2 Jbb Truss Truss Type aty Ply 22137-Klein, Ron -Klein Re -Roof 22137 E04G Hip Truss 1 1 Job Reference (optional) cast UUaS[ i FUSS, rUM i t 1MKU1z, t-L. J4a4ti /.ZbU s May 11 Zo11 Mi I eK Industries, Inc. Fri Sep 30 10:22AU 2011 Page 2 ID:ZycEGXaG15uaiv1 hsBRj37zPYdX-arbKLtlKyGdtg Ug54B819CBrfYSzjcu_ohW5lyyYUND NOTES 10IHanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)1131b down and 2721b up at 7-0-0,113 Ib down and 272 Ib up at 9-0-12, 1131b down and 272 Ib up at 11-0-12,113 Ib down and 272 Ib up at 12-6-0,1131b down and 272 Ib up at 13-11-4, and 113 Ib down and 272 lb up at 15-11-4, and 228 lb down and 586 lb up at 18-0-0 on top chord, and 259 lb down and 185 lb up at 7-0-0, 47 lb down and 9 lb up at 9-0-12, 47 Ib down and 9 lb up at 11-0-12, 47 Ib down and 9 Ib up at 12-6-0, 47 Ib down and 9 Ib up at 13-11-4, and 47 Ib down and 9 Ib up at -15-11-4, and 259 lb down and 185 lb up at 17-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOADCASE(S) Standard 1) Regular: Lumber[ ncrease=1.25,Plate Increase=1.25 Uniform Loads (plf) Vert: A-C=-44, C-E=-44, E-G=-44, L-O=-10 Concentrated Loads (lb) Vert: C=-94(B) E=-187(B) J=-23(B) K=-1 73(B) 1=-23(B) D=-94(B) H=-173(B) R=-94(B) S=-94(B) T=-94(B) U=-94(B) V=-23(B) W=-23(B) X=-23(B) Job Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 22137 FG02 Flat Truss 2 1 Job Reference (optional) East Coast I russ, FORT PIERCE, FL. 34946 n 7.250 s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:22:42 2011 Page 1 ID:ZycEGxaGi5uaivlhsBRj37zPYdX WDj41ZKaTufb3npUBcAmFdHIEMHQBeZHG??CMryYUNB 3-7-0 A 3A = B 2A 11 Scale=1:13.1 YI.Y - 2A 11 247#/-396# 3-7-0 3-7-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud TCLL 20.0 Plateslncrease 1.25 TC 0.22 Vert(LL) 0.02 C-D >999 240 TCDL 7.0 Lumberincrease 1.25 BC 0.28 Vert(TL) 0.02 C-D >999 180 BCLL 0.0 * Rep Stress Incr NO WB 0.00 Horz(TL) 0.00 C n/a n/a BCDL 5.0 Code FBC2007/TP12002 (Matrix-M) LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD BOT CHORD 2 X 6 SYP No.2 WEBS 2 X 4 SYP No.3 BOT CHORD REACTIONS (lb/size) D=208/0-7-0, C=188/Mechanical Max UpliftD=-396(LC 4), C=-357(LC 4) Max Grav D=247(LC 2), C=224(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. PLATES GRIP MT20 244/190 Weight: 22 lb, FT = 20% Structural wood sheathing directly applied or 3-7-0 oc purlins, except end verticals. Rigid ceiling directly applied or 10-0-0 ocbracing. MiTek recommends that Stabil izers and required cross bracing be installed during truss erection, in accordancewith Stabilizer) nstal lation guide. NOTES 1) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveloads. 3) Provide adequate drainage to preventwaterponding. 4) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Referto girder(s) fortruss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 396 lb uplift atjoint D and 357 lb uplift atjoint C. 8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 260 lb down and 445 Ib up at 1-7-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard Continued on page 2 Job Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 22137 FG02 Flat Truss 2 1 Job Reference (optional) tasi l;oasl I russ, rUK I NILKI:L, FL. 3494b 1.25U s May 11 2U11 Mtl eK Industries, Inc. Fri Sep 30 10:22:42 2011 Page 2 ID:ZycEGXaGi5uaivlhsBRj37zPYdX WDj41ZKaTutb3npUBcAmFdHIEMHQBeZHG??CMryYUNB LGAD CASES) Standard 1) Regular: Lumberl ncrease=1.25, Plate I ncrease=1.25 Uniform Loads (plf) Vert: A-B=-44, C-D=-10 Concentrated Loads (lb) Vert: E=-218(B) Job Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 22137 MV5 Valley Truss 1 1 + Job Reference (optional) East Coast Truss, FORT PIERCE, FL. 34946 3A 4 7.250 s May 112011 MiTek Industries, Inc. Fri Sep 30 10:22:44 2011 Page 1 ID:ZycEGXaGi5uaivl hsBRj37zPYdX-ScrrAFLq?V7JJ5zsJ 1 DEK2Md59?IfY2ajJUIRjyYU N9 2A II 2A II c Scale =1:9.8 5-0-8 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plateslncrease 1.25 TC 0.26 Vert(LL) n/a - n/a 999 MT20 244/190 TCDL 7.0 Lumberincrease 1.25 BC 0.10 Vert(TL) n/a - n/a 999 BCLL 0.0 * Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 n/a n/a BCDL 5.0 Code FBC2007/TPI2002 (Matrix) Weight: 14lb FT = 20% LUMBER BRACING TOPCHORD 2X4SYPNo.2 TOPCHORD Structural wood sheathing directlyapplied or5-0-8 oc BOTCHORD 2X4SYPNo.2 purlins, except end verticals. WEBS 2 X 4 SYP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordancewithStabilizerinstallation uide. REACTIONS (lb/size) A=100/5-0-8, C=100/5-0-8 MaxHorzA=100(LC4) Max UpliftA=-161(LC 4), C=-186(LC 4) Max GravA=119(LC 2), C=119(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed forbasic load combinations, which include cases with reductions formultiple concurrent liveloads. 3) Gable requires continuous bottomchord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 161 lb uplift atjointA and 186 lb uplift atjoint C. 7) "Semi -rigid pitchbreaks including heels" Memberend fixity model was used in the analysis and design of this truss. LOADCASE(S) Standard Job Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 22137 MV7 Valley Truss 1 1 Job Reference (optional) Last Coast Truss, FORT PIERCE, FL. 34946 3x4 7.250 s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:22:45 2011 Page 1 ID:ZycEGXaGi5uaivlhsBRj37zPYdXwoPDObMSmpFAwFY3tkkTsFvl ZKSO71jyyEszAyYUN8 3x4 11 B 2A 11 Scale=1:13.2 7-" 7-0-8 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plateslncrease 1.25 TC 0.51 Vert(LL) n/a - n/a 999 MT20 244/190 TCDL 7.0 Lumberincrease 1.25 BC 0.13 Vert(TL) n/a - n/a 999 BCLL 0.0 * Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 C n/a n/a BCDL 5.0 Code FBC2007/TPI2002 (Matrix) Weight: 21 lb FT = 20% LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD BOT CHORD 2 X 4.SYP No.2 WEBS 2 X 4 SYP No.3 BOT CHORD REACTIONS (lb/size) A=154/7-0-8, C=154/7-0-8 Max HorzA=154(LC 4) Max UpliftA=-248(LC 4), C=-286(LC 4) Max GravA=183(LC 2), C=183(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD B-C=-141/280 Structural wood sheathing directly applied or6-0-0 oc purlins, except end verticals. Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends thatStabilizers and required cross bracing be installed during truss erection, in accordancewith Stabilizerinstallation guide. NOTES 1) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. 11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed; LumberDOL=1.60 plate grip DOL=1.60 2) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent Iiveloads. 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrentwith any other live loads. 5) * This truss has been designed fora live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 248 lb uplift atjointA and 286 lb uplift atjoint C. 7) "Srmi-rigid pitchbreaks including heels" Memberend fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 22137 MV9 Valley Truss 1 1 Job Reference (optional) East Coast Truss, FORT PIERCE, FL. 34946 7.250 s May 112011 MiTek Industries, Inc. Fri Sep 30 10:22:46 2011 Page 1 ID:ZycEGXaGi5uaivlhsBRj37zPYdX O?ybbwN4X6NOYP7FQSFiPTR?rzhe7RfsAczPVcyYUN7 9-0-8 2A II C E D 3A 1A II 2A II LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud TCLL 20.0 Plateslncrease 1.25 TC 0.18 Vert(LL) n/a - n/a 999 TCDL 7.0 Lumberincrease 1.25 BC 0.07 Vert(TL) n/a - n/a 999 BCLL 0.0 * Rep Stress Incr YES WB 0.12 Horz(TL) -0.00 D n/a n/a BCDL 5.0 Code FBC2007/TPI2002 (Matrix) LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD BOT CHORD 2 X 4 SYP No.2 WEBS 2 X 4 SYP No.3 BOT CHORD OTHERS 2 X 4 SYP No.3 REACTIONS (lb/size) A=82/9-0-8, D=82/9-0-8, E=252/9-0-8 Max HorzA=208(LC 4) Max UpliftA=-101(LC 4), D=-153(LC 4), E=-467(LC 4) Max GravA=98(LC 2), D=97(LC 2), E=298(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. WEBS B-E=-247/483 Scale=1:16.7 PLATES GRIP MT20 244/190 Weight: 29 lb FT = 20% Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends thatStabilizers and required cross bracing be installed during truss erection, in accordancewithStabilizerinstallationguide. NOTES 1) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveloads. 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed fora 10.0 psf bottomchord live load nonconcurrentwith any other live loads. 5) * This truss has been designed fora live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 101 lb uplift atjointA, 153 lb uplift atjoint D and 467 lb uplift atjoint E. 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASES) Standard Job Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 22137 _CJ1 Jack -Open Truss 10 1 Job Reference (optional) East Coast Truss, FORT PIERCE, FL. 34946 7.250 s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:20:18 2011 Page 1 ID:ZycEGXaGi5uaivlhsBRj37zPYdX kWoeXKaFOekoofpomMb_PFJhaJBaRWv48b7aIByYUPR Scale =1:7.9 , , 0-10-8 p 1 8 2-M I-M Plate Offsets iX Y): [B:0-1-14 0-0-2] LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plateslncrease 1.25 TC 0.22 Vert(LL) 0.00 E >999 240 MT20 244/190 TCDL 7.0 Lumberincrease 1.25 BC 0.04 Vert(TL) 0.00 E >999 .180 BCLL 0.0 * Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 B n/a n/A BCDL 5.0 Code FBC2007/TPI2002 (Matrix-M) Weight: 9 lb FT = 20% LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD BOT CHORD 2 X 4 SYP No.2 BOTCHORD REACTIONS (lb/size) B=199/0-8-0, D=-33/Mechanical, C=-25/Mechanical MaxHorzB=136(LC4) Max UpliftB=-612(LC 4), D=-41(LC 2), C=-32(LC 2) Max Grav B=244(LC 2), D=124(LC 4), C=110(LC 4) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Structural wood sheathing directly applied or 1-0-0 oc purlins. Rigid ceiling directly applied or 10-0-0 ocbracing. MiTek recommends thatStabilizers and required cross bracing be installed during truss erection, in accordancewith Stabilizerinstal lation guide. NOTES 1) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveloads. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) *This truss has been designed for alive load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 612 lb uplift atjoint E, 41 lb uplift atjoint D and 32 lb uplift atjoint C. 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard J'ob Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 22137 —CJ1A JACK -OPEN TRUSS 2 1 Job Reference (optional) East Coast Truss, FORT PIERCE, FL. 34946 7.250 s May 112011 MiTek Industries, Inc. Fri Sep 30 10:20:20 2011 Page 1 ID:ZycEGXaGi5uaivl hsBRj37zPYdX gv8Py7cVwF_klzzBtndSUg0136gSiQPNcvchN3yYUPP 2-0-0 Scale =1:7,9 i i 0-10-8 ` p-1 B 2-M 1-0-0 Plate Offsets (X Y): [B:0-1-6 0-0-2] LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plateslncrease 1.25 TC 0.22 Vert(LL) -0.00 G n/r 120 MT20 244/190 TCDL 7.0 Lumberincrease 1.25 BC 0.20 Vert(TL) -0.00 G n/r 120 BCLL 0.0 " Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 n/a n/a BCDL 5.0 Coda FBC2007frPI2002 (Matrix-M) Weight: 9 lb FT = 20% LUMBER BRACING TOP CHORD 2X6SYPNo.2 TOPCHORD Structural woodsheathing directlyapplied or 1-0-0 oc BOTCHORD 2 X 4 SYP No.2 purlins. BOTCHORD Rigid ceiling directly applied or6-0-Oocbracing. MiTek recommends thatStabilizers and required cross bracing be installed during truss erection, in accordancewithStabilizerinstallation guide. REACTIONS (lb/size) C=1 41 /Mechanical, D=O/Mechanical Max HorzC=-1392(LC 4), D=1528(LC 4) Max UpliftC=-436(LC4) Max Grav C=171(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD B-C=-1458/554 BOTCHORD B-D=-527/1528 NOTES 1) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveloads. 3) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) PFbvide mechanical connection (by others) of truss to bearing plate capable of withstanding 436 lb uplift atjoint C. 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Job Truss Truss Type city Ply 22137-Klein, Ron -Klein Re -Roof 22137 —CAB Jack -Open Truss 10 1 Job Reference (optional) East Coast Truss, FORT PIERCE, FL. 34946 7.250 s May 112011 MiTek Industries, Inc. Fri Sep 30 10:20:21 2011 Page 1 ID:ZycEGXaGi5uaiv1hsBRj37zPYdX 85in9Lc7hZ6bf7)WRV9h1ux9VWC etfWrZLEvwyYUPO L 2-0-0 1-" Scale =1:6.6 4 d 4A = 1 0-10-8 ,0-1-8i 2-M 1-M Plate Offsets (X Y): [B:0-1-12 0-2-0] LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plateslncrease 1.25 TC 0.43 Vert(LL) 0.00 G >999 240 MT20 244/190 TCDL 7.0 Lumberincrease 1.25 BC 0.12 Vert(TL) 0.00 G >999 180 BCLL 0.0 * Rep Stress Incr YES WB 0.00 Horc(TL) 0.00 B n/a n/a BCDL 5.0 Code FBC2007/TPI2002 (Matrix-M) Weight: 6lb FT=20% LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD BOT CHORD 2 X 4 SYP No.2 BOTCHORD REACTIONS (lb/size) B=204/0-8-0, D=-37/Mechanical, C=-26/Mechanical Max HorzB=102(LC 4) Max UpliftB=-616(LC 4), D=-46(LC 2), C=-32(LC 2) Max Grav B=249(LC 2), D=137(LC 4), C=101(LC 4) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD B-C=-448/166 BOT CHORD B-D=-126/325 Structural wood sheathing directly applied or 1-0-0 oc purlins. Rigid ceiling directly applied or 10-0-0 ocbracing. MiTek recommends thatStabi I izers and required cross bracing be installed during truss erection, in accordanceWthStabilizerinstallation guide. NOTES 1) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveloads. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 616lb uplift atjoint E, 46 lb uplift atjoint D and 32 lb uplift atjoint C. 7) "Semi -rigid pitchbreaks including heels" Memberend fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 22137 _CJ1V JACK -OPEN TRUSS 4 1 Job Reference (optional) East Coast Truss, FORT PIERCE, FL. 34946 7.250 s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:20:23 2011 Page 1 ID:ZycEGXaGi5uaivlhsBRj37zPYdX-4UpXaleODAMJuQhmYvB96J0YJKvv6n8pitgL O YUPM 2-M Scale = 1:8.1 v Id 24)-0 1-1-8 - Plate Offsets MY): [B:0-3-14,0-0-12] LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plateslncrease 1.25 TC 0.22 Vert(LL) 0.00 G >999 240 MT20 244/190 TCDL 7.0 Lumberincrease 1.25 BC 0.03 Vert(TL) 0.00 G >999 180 BCLL 0.0 * Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 B n/a n/a BCDL 5.0 Code FBC2007/TPI2002 (Matrix-M) Weight:10 lb FT = 20% LUMBER BRACING TOP CHORD 2X6SYPNo.2 TOPCHORD Structural wood sheathing directly applied or1-1-8oc BOT CHORD 2 X 4 SYP No.2 purlins. BOTCHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends thatStabilizers and required cross bracing be installed during truss erection, in accordancewith Stabilizer Installation guide. REACTIONS (lb/size) B=196/0-8-0, C=-46/Mechanical Max HorzB=142(LC 4) Max UpliftB=-584(LC 4), C=-58(LC 2) Max Grav B=239(LC 2), C=192(LC 4) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveloads. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any othermembers. 5) Refer to girder(s) for truss to truss connections. 6) Bearing atjoint(s) B considers parallel to grain value usingANSI/TPI 1 angle to grain formula. Building designershould verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 584lb uplift atjoint E and 58 lb uplift atjoint C. 8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOADCASE(S) Standard Job Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 22137 —CJ3 Jack -Open Truss 10 1 Job Reference (optional)_ East Coast Truss, FORT PIERCE, FL. 34946 A 7.250 s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:20:25 2011 Page 1 ID:ZycEGXaGi5uaivlhsBRj37zPYdX 1bd?jgekocl7kr9gKDdBk6uo7aBage6lAJS2HyYUPK Scale=1:11.3 2-M M-0 Plate Offsets (X Y): [B:0-2-0 0-1-121 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plateslncrease 1.25 TC 0.22 Vert(LL) -0.00 G >999 240 MT20 244/190 TCDL 7.0 Lumberincrease 1.25 BC 0.04 Vert(TL) -0.00 G >999 .180 BCLL 0.0 " Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 B n/a n/a BCDL 5.0 Code FBC2007/TPI2002 (Matrix-M) Weight:17 lb FT = 20% LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD BOT CHORD 2 X 4 SYP No.2 BOTCHORD REACTIONS (lb/size) C=42/Mechanical, B=196/0-8-0, D=9/Mechanical Max HorzB=206(LC 4) Max UpliftC=-76(LC 4), B=-497(LC 4) MaxGravC=50(LC 2), B=237(LC 2), D=29(LC 3) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD B-C=-322/77 Structural wood sheathing directly applied or 3-0-0 oc purlins. Rigid ceiling directly applied or 10-0-0 ocbracing. MiTek recommends thatStabilizers and required cross bracing be installed duringtruss erection, in accordancewith Stabilizerinstal lation guide. NOTES 1) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and rightexposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveloads. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrentwith any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 76 lb uplift atjoint C and 497 lb uplift atjoint E. 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOADCASE(S) Standard Job Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 22137 —CJ3A JACK -OPEN TRUSS 2 1 Job Reference (optional) East Coast Truss, FORT PIERCE, FL. 34946 7.250 s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:20:27 2011 Page 1 ID:ZycEGXaGi5uaivl hsBRj37zPYdX-zF32QPhuGPsIN2?XnIF6H9BEb As2a8PDUoY7AyYUPI 2-M 3-0-0 2-M 3-0-0 Plate Offsets MY): [B:0-8-6,0-0-101 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud TCLL 20.0 Plateslncrease 1.25 TC 0.22 Vert(LL) -0.02 D n/r 120 TCDL 7.0 Lumberincrease 1-.25 BC 0.41 Vert(TL) -0.02 D n/r 120 BCLL 0.0 * Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 n/a n/a BCDL 5.0 Code FBC2007ITP12002 (Matrix-M) LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD BOT CHORD 2 X 4 SYP No.2 BOTCHORD REACTIONS (lb/size) C=247/Mechanical,D=O/Mechanical Max Horz C=-1559(LC 4), D=1766(LC 4) Max UpliftC=-733(LC 4) Max Grav C=296(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD B-C=-1716/688 BOTCHORD B-D=-631/1766 Scale=1:11.3 PLATES GRIP MT20 244/190 Weight:17 lb FT = 20% Structural wood sheathing directly applied or 3-0-0 oc purlins. Rigid ceiling directly applied or6-0-0 ocbracing. MiTek recommends thatStabilizers and required cross bracing be installed during truss erection, in accordancewith Stabi lizerinstallation guide. NOTES 1) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat.11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveloads. 3) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrentwith any other live loads. 4) *This truss has been designed for alive load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Pravide mechanical connection (by others) of truss to bearing plate capable of withstanding 733 lb uplift atjoint C. 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 22137 —CJ36 Jack -Open Truss 10 1 Job Reference (optional) East Coast Truss, FORT PIERCE, FL. 34946 7.250 s May 112011 MiTek Industries, Inc. Fri Sep 30 10:20:28 2011 Page 1 ID:ZycEGXaGi5uaivlhsBRj37zPYdX RRdOdkiWlj_c BajLTnLpMkPCLcynlOYS8Y6fcyYUPH 3-0-0 Scale = 1:9.8 A 4A = LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl L/d TCLL 20.0 Plateslncrease 1.25 TC 0.21 Vert(LL) -0.00 G >999 240 TCDL 7.0 Lumberincrease 1.25 BC 0.03 Vert(TL) -0.00 G >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 B n/a n/a BCDL 5.0 Code FBC2007/TPI2002 (Matrix-M) LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD BOT CHORD 2 X 4 SYP No.2 BOTCHORD REACTIONS (lb/size) C=42/Mechanical, B=196/0-8-0, D=9/Mechanical Max HorzB=155(LC4) Max UpliftC=-68(LC 4), B=-503(LC 4) Max Grav C=50(LC 2), B=237(LC 2), D=27(LC 3) FORCES (lb) -Max. Comp./Max. Ten. -AII forces 250 (lb) or less except when shown. TOP CHORD B-C=-275/67 PLATES GRIP MT20 244/190 Weight:17 lb FT = 20% Structural wood sheathing directly applied or3-0-0 oc purlins. Rigid ceiling directly applied or 10-0-0 ocbracing. MiTek recommends that Stabilizers and required � cross bracing be installed during truss erection, in accordancewith Stabilizer) nstallation guide. NOTES 1) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat.11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveloads. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrentwith any other live loads. 4) *This truss has been designed for alive load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 68lb uplift atjoint C and 503 lb uplift atjoint E. 7) "Semi -rigid pitchbreaks including heels" Memberend fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 22137 —CJ3V Jack -Open Truss 4 1 Job Reference (optional) East Coast Truss, FORT PIERCE, FL. 34946 7.250 s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:20:30 2011 Page 1 ID:ZycEGXaGi5uaivlhsBRj37zPYdX Ng1B2QjnZKFJEVk6TuppunplYBHRFxtrvSlDkUyYUPF 2-0-0 3-0-0 A LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud TCLL 20.0 Plateslncrease 1.25 TC 0.22 Vert(LL) -0.00 G >999 240 TCDL 7.0 Lumberincrease 1.25 BC 0.03 Vert(TL) -0.00 G >999 180 BCLL 0.0 * Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 B n/a n/a BCDL 5.0 Code FBC2007/TP12002 (Matrix-M) LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD BOT CHORD 2 X 4 SYP No.2 BOTCHORD REACTIONS (lb/size) C=41/Mechanical, B=197/0-8-0, D=9/Mechanical Max HorzB=206(LC 4) Max UpliftC=-73(LC 4), B=-498(LC4) Max Grav C=49(LC 2), B=239(LC 2), D=28(LC 3) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD B-C=-268/77 Scale=1:11.3 PLATES GRIP MT20 244/190 Weight:17 lb - FT = 20% Structural wood sheathing directly applied or 3-0-0 oc purlins. Rigid ceiling directly applied or6-0-0 ocbracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordancewith Stabilized nstal lation guide. NOTES 1) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveloads. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrentwith any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any othermembers. 5) Refer to girder(s) for truss to truss connections. 6) Bearing atjoint(s) B considers parallel to grain value usingANSI/TPI 1 angle to grain formula. Building designershould verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 73 lb uplift atjoint C and 498 lb uplift atjoint E. 8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 22137 —CJ5 Jack -Open Truss 11 1 Job Reference (optional) East Coast Truss, FORT PIERCE, FL. 34946 , 7.250 s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:20:32 2011 Page 1 ID:ZycEGXaGi5uaivl hsBRj37zPYdX-JDsxT6115xV1 TptValrHzCu4l yyyjrN6MmWJoNyYUPD 5-0-0 Scale=1:14.6 Plate Offsets (X,Y): [B:0-2-0,0-1-12] LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plateslncrease 1.25 TC 0.22 Vert(LL) -0.01 D-G >999 240 MT20 244/190 TCDL 7.0 Lumberincrease 1.25 BC 0.09 Vert(TL) -0.02 D-G >999 180 BCLL 0.0 * Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 C n/a n/a BCDL 5.0 Code FBC2007/TP12002 (Matrix-M) Weight: 25 lb FT = 20% LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD Structural wood sheathing directlyapplied or5-0-0 oc BOT CHORD 2 X 4 SYP No.2 purlins. BOTCHORD Rigid ceiling directly applied or 10-0-0 ocbracing. MiTek recommends that Stabilizers and required cross bracing be installed duringtruss erection, in accordancewith Stabilized nstallation guide. REACTIONS (lb/size) C=93/Mechanical, B=240/0-8-0, D=22/Mechanical Max HorzB=278(LC 4) Max UpliftC=-207(LC 4), B=-542(LC 4) Max Grav C=112(LC 2), B=289(LC 2), D=54(LC 3) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveloads. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrentwith any other live loads. 4) *This truss has been designed for alive load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 207lb uplift atjoint C and 542 lb uplift atjoint E. 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOADCASE(S) Standard Job Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 22137 —CJSA JACK -OPEN TRUSS 1 1 Job Reference (optional) East Coast Truss, FORT PIERCE, FL. 34946 7.250 s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:20:34 2011 Page 1 ID:ZycEGXaGi5uaivlhsBRj37zPYdX Gb_huonHdZlli6ltijt3dzMhmYSBItRg4?QtGyYUPB 2-M 5-0-0 r_i 5-0-0 2-0-0 1-0-0 Plate Offsets (X,Y): rB:0-5-1,0-3-41 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud TCLL 20.0 Plateslncrease 1.25 TC 0.47 Vert(LL) -0.07 D n/r 120 TCDL 7.0 Lumberincrease 1.25 BC 0.48 Vert(TL) -0.07 D n/r 120 BCLL 0.0 * Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 n/a n/a BCDL 5.0 Code FBC2007/TPI2002 (Matrix-M) LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD BOT CHORD 2 X 6 SYP No.2 BOTCHORD REACTIONS (lb/size) C=355/Mechanical,D=O/Mechanical Max Horz C=-2091(LC 4), D=2370(LC 4) Max UpliftC=-1038(LC 4) Max Grav C=424(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD B-C=-2321/944 BOT CHORD B-D=-860/2370 Scale=1:14.6 PLATES GRIP MT20 244/190 Weight: 29 lb FT = 20% Structural wood sheathing directly applied or 4-4-5 oc purlins. Rigid ceiling.directly applied orb-0-0 ocbracing. MiTek recommends thatStabilizers and required cross bracing be installed during truss erection, in accordancewith Stabilizerinstallation guide. NOTES 1) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Thistruss has been designed for basic load combinations, which include caseswith reductions for multiple concurrent liveloads. 3) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrentwith any other live loads. 4) * This truss has been designed fora live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and apy other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1038lb uplift atjointC. 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 22137 —CJ56 Jack -Open Truss 10 1 Job Reference (optional) East Coast Truss, FORT PIERCE, FL. 34946 3A = 3.00 12 7.250 s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:20:35 2011 Page 1 ID:ZycEGXaGi5uaivlhsBRj37zPYdX koY468nvOstcKGc4FRP_brWaP9zlwC6a3kk_PiyYUPA 5-0-0 2-M 305#/-614# 5-0-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud TCLL 20.0 Plateslncrease 1.25 TC 0.28 Vert(LL) -0.02 B-D >999 240 TCDL 7.0 Lumberincrease 1.25 BC 0.15 Vert(TL) -0.04 B-D >999 180 BCLL 0.0 * Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 C n/a n/a BCDL 5.0 Code FBC2007/TP12002 (Matrix) LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD BOT CHORD 2 X 4 SYP No.2 BOTCHORD REACTIONS (lb/size) C=75/Mechanical, B=253/0-8-0, D=23/Mechanical MaxHorzB=204(LC4) Max UpliftC=-164(LC 4), B=-614(LC 4) Max Grav C=92(LC 2), B=305(LC 2), D=69(LC 3) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Scale=1:13.8 PLATES GRIP MT20 244/190 Weight: 25 lb FT = 20% Structural wood sheathing directly applied or5-0-0 oc purlins. Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends thatStabilizers and required cross bracing be installed during truss erection, in accordanceWthStabilizerinstallation guide. NOTES 1) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and rightexposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as perANSI/TPI 1. 3) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveloads. 4) Gable studs spaced at 2-0-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) *This truss has been designed for alive load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 164lb uplift atjoint C and 614 lb uplift atjoint B. 9) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Job- Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 22137 —CJSV Jack -Open Truss 4 1 Job Reference (optional) East Coast Truss, FORT PIERCE, FL. 34946 7.250 s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:20:37 2011 Page 1 ID:ZycEGXaGi5uaivlhsBRj37zPYdX gAggWppAwU7IQamSNsRSgGb)mzfA06ctW2D4TayYUP6 2-0-0 5-0-0 Scale=1:14.6 fo d d A 2-0-0 5-0-0 Plate Offsets (X,Y): [B:0-2-0,0-1-12] LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plateslncrease 1.25 TC 0.22 Vert(LL) 0.02 D-G >999 240 MT20 244/190 TCDL 7.0 Lumberincrease 11.25 BC 0.09 Vert(TL) -0.02 D-G >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 C n/a n/a BCDL 5.0 Code FBC2007/TPI2002 (Matrix-M) Weight: 25lb FT = 20% LUMBER BRACING TOP CHORD 2X6SYPNo.2 TOPCHORD Structural wood sheathing directly applied or5-0-0oc BOT CHORD 2 X 4 SYP No.2 purlins. BOTCHORD Rigid ceiling directly applied or6-0-0 ocbracing. MiTek recommends thatStabilizers and required cross bracing be installed duringtruss erection, in accordancewithStabilizerinstallation guide. REACTIONS (lb/size) C=93/Mechanical, B=239/0-8-0, D=22/Mechanical Max Horz B=278(LC 4) Max UpliftC=-208(LC 4), B=-539(LC 4), D=-1(LC 7) Max Grav C=113(LC 2), B=288(LC 2), D=53(LC 3) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed; LumberDOL=1.60 plate grip DOL=1.60 2) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveloads. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrentwith any other live loads. 4) *This truss has been designed fora live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Bearing atjoint(s) B considers parallel to grain value usingANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 208lb uplift atjoint C, 539 lb uplift atjoint E and 1 lb uplift atjoint D. 8) "Semi -rigid pitchbreaks including heels" Memberend fixity model -was used in the analysis and design of this truss. LOADCASE(S) Standard Job Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 22137 —EJ7 Jack -Partial Truss 13 1 Job Reference (optional) East Coast Truss, FORT PIERCE, FL. 34946 7.250 s May 112011 MiTek Industries, Inc. Fri Sep 30 10:20:39 2011 Page 1 ID:ZycEGXaGi5uaivlhsBRj37zPYdX cZnaxVgQR5N2puwrUHTwmhhGkmJzs06AzMiBYTyYUP6 2-M 3-5-15 3-6-1 7-M 2-0-0 7-M LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d TCLL 20.0 Plateslncrease 1.25 TC 0.32 Vert(LL) 0.08 D-G >999 240 TCDL 7.0 Lumberincrease 1.25 BC 0.20 Vert(TL) -0.10 D-G >847 180 BCLL 0.0 * Rep Stress Incr YES WB 0.00 Horz(TL) -0.01 C n/a n/a BCDL 5.0 Code FBC2007/TP12002 (Matrix-M) LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD BOT CHORD 2 X 4 SYP No.2 BOTCHORD REACTIONS (lb/size) C=138/Mechanical, B=292/0-8-0, D=33/Mechanical Max HorzB=350(LC 4) Max UpliftC=-320(LC 4), B=-612(LC 4), D=-2(LC 4) Max GravC=167(LC 2), 13=350(LC 2), D=79(LC 3) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD B-C=-376/371 BOT CHORD B-D=-467/342 Scale=1:17.9 PLATES GRIP MT20 244/190 Weight: 33 lb FT = 20% Structural wood sheathing directly applied or 6-0-0 oc purlins. Rigid ceiling directly applied or 10-0-0 ocbracing. MiTek recommends that Stabi I izers and required cross bracing be installed during truss erection, in accordancewith Stabilizer) nstal lation guide. NOTES 1) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and rightexposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for basic load combinations; which include cases with reductions for multiple concurrent liveloads. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrentwith any other live loads. 4) "This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 320 lb uplift atjoint C, 612 lb -uplift atjoint E and 2 lb uplift atjoint D. 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 22137 —EJ713 Jack -Partial Truss 13 1 Job Reference (optional) East Coast Truss, FORT PIERCE, FL. 34946 7.250 s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:20:41 2011 Page 1 ID:ZycEGXaGi5uaivlhsBRj37zPYdX ZyvLMBsgzidm2B3DchWOr6mcbaOcKwcTRgBlcMyYUP4 2-M 3-6-10 f 3-" Scale=1:17.5 3.00 12 167#/ 350#/-6309 v Ti B A B1 77#/ 4A = i i 7-0-0 2-0-0 7-0-0 Plate Offsets (X Y): [13:012-0 0-1-121 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plateslncrease 1.25 TC 0.30 Vert(LL) 0.08 D-G >999 240 MT20 244/190 TCDL 7.0 Lumberincrease 1-:25 BC 0.19 Vert(TL) -0.09 D-G >913 180 BCLL 0.0 * Rep Stress Incr YES WB 0.00 Horz(TL) -0.01 C n/a n/a - BCDL 5.0 Code FBC2007/TP12002 (Matrix-M) Weight: 32 lb FT = 20% LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD BOT CHORD 2 X 4 SYP No.2 BOT CHORD REACTIONS (lb/size) C=138/Mechanical, B=292/0-8-0, D=33/Mechanical Max HorzB=263(LC 4) Max UpliftC=-302(LC 4), B=-630(LC 4), D=-3(LC 4) Max Grav C=167(LC 2), B=350(LC 2), D=77(LC 3) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD B-C=-359/345 BOTCHORD B-D=-377/303 Structural wood sheathing directly applied or6-0-0 oc purlins. Rigid ceiling directly applied or 10-0-0 ocbracing. MiTek recommends thatStabilizers and required cross bracing be installed during truss erection, in acco rdan cewith Stabilizer Instal Iation guide. NOTES 1) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat.11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveloads. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) *This truss has been designed for alive load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 302 lb uplift atjoint C, 630 lb uplift atjoint E and 3 lb uplift at joint D. 7) "Semi -rigid pitchbreaks including heels" Memberend fixitymodel was used in the analysis and design of this truss. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 22137 —EJ7V Jack -Partial Truss 7 1 Job Reference o tional East toast I russ, FURT PIERCE, FL. 34946 7.250 s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:20:42 2011 Page 1 ID:ZycEGXaGi5uaivlhsBRj37zPYdX 18TjaXtlkOlcgLeQAP1dNJJmp LU3MrcgK)T9oyYUP3 3-" 1 3-6-0 Plate Offsets (X,Y): LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud TCLL 20.0 Plateslncrease 1.25 TC 0.33 Vert(LL) 0.09 D-G >906 240 TCDL 7.0 Lumberincrease 1�25 BC 0.21 Vert(TL) -0.10 D-G >833 180 BCLL 0.0 * Rep Stress Incr YES WB 0.00 Horz(TL) -0.01 C n/a n/a BCDL 5.0 Code FBC2007/TP12002 (Matrix-M) LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD BOTCHORD 2X4SYPNo.2 BOTCHORD REACTIONS (lb/size) C=1 41 /Mechanical, B=288/0-8-0, D=34/Mechanical Max HorzB=350(LC 4) Max UpliftC=-326(LC 4), B=-603(LC 4), D=-6(LC 4) Max GravC=1 71 (LC 2), B=346(LC 2), D=79(LC 3) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Scale=1:17.9 PLATES GRIP MT20 244/190 Weight: 33 lb FT = 20% Structural wood sheathing directly applied or 6-0-0 oc purlins. Rigid ceiling directly applied or6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordancewith Stabilizerinstallationguide. NOTES 1) Wind: ASCE 7-05;150mph (3-second.gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable endzone; cantilever leftand rightexposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveloads. 3) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed fora live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Referto girder(s) for truss to truss connections. 6) Bearing atjoint(s)Bconsiders parallel tograin value usingANSI/TPI1 angle to grain formula. Building designershoulc verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 326 lb uplift atjoint C, 603 lb uplift atjoint E and 6 lb uplift atjoint D. 8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 22137 —HJ7 Diagonal Hip Girder 5 1 Job Reference (optional) East Coast Truss, FORT PIERCE, FL. 34946 7.250 s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:20:45 2011 Page 1 ID:ZycEGXaGi5uaivlhsBRj37zPYdX Rj9sCYvBlxeBXpN?rXaK?yxFhBHUGfl3Ml9Vm7yYUP0 A 2-9-15 5-0-4 453#/-957# Scale: l /2"=1' Camber =1/8 in 9-8-13 g 210 1 2-9-15 9-10-13 Plate Offsets MY): [F:0-5-1,0-0-121 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plateslncrease 1.25 TC 0.48 Vert(LL) -0.18 F-I >641 240 MT20 244/190 TCDL 7.0 Lumberincrease 11.25 BC 0.57 Vert(TL) -0.31 F-I >371 180 BCLL 0.0 * Rep Stress Incr NO WB 0.28 Horz(TL) -0.02 F n/a n/a BCDL 5.0 Code FBC2007/TP12002 (Matrix-M) Weight: 53 lb FT = 20% LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD BOT CHORD 2 X 4 SYP No.2 WEBS 2 X 4 SYP No.3 BOT CHORD REACTIONS (lb/size) D=143/Mechanical, B=367/0-11-5, F=183/Mechanical Max HorzB=351(LC 4) Max UpliftD=-345(LC 4), B=-957(LC 4), F=-226(LC 7) Max Grav D=174(LC 2), B=453(LC 2), F=246(LC 3) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD B-C=-717/967 BOT CHORD B-F=-1070/679 WEBS C-F=-698/1100 Structural wood sheathing directly applied or 6-0-0 oc purlins. Rigid ceiling directly applied orb-0-5 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordancewith Stabilizer Installationguide. NOTES 1) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveloads. 3) This truss is not designed to support a ceiling and is not intended for use where aesthetics area consideration. 4) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed fora live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 270-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 345lb uplift atjoint D, 957 lb uplift atjoint G and 226 lb uplift atjoint F. 8) "Sp.mi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. Continued on page 2 J•Db Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 22137 —HJ7 Diagonal Hip Girder 5 1 Job Reference (optional) East Coast I russ, FORT PIERCE, FL. 34946 _ 7.250 s May 11 zu11 MI I eK Industries, Inc. Fri Sep 3u 1 u:ZU:45 zu11 rage z ID:ZycEGXaGi5uaiv1hsBRj37zPYdX Rj9sCYvBWBXpN?rXaK?yxFhBHUGFl3MI9Vm7yYUP0 NOTES 9)X langer(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 20 lb up at 1-4-11, 20lb up at 1-4-10, 24 lb down and 37 lb up at 4-2-10, 24 lb down and 37 lb up at 4-2-10, and 58 lb down and 168 lb up at 7-0-9, and 58 lb down and 168 lb up at 7-0-9 on top chord, and 19 lb up at 1-4-11, 19 lb up at 1-4-10,1 lb up at 4-2-10, 1 lb up at 4-2-10, and 24 lb down at 7-0-9, and 24 lb down at 7-0-9 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumberincrease=1.25, Plate lncrease=1.25 Uniform Loads (plf) Vert: A-D=44, E-G=-10 Concentrated Loads (lb) Vert: H=41(F=20, B=20)1=38(F=19, B=19) J=5(F=2, B=2) K=-97(F=-49, B=-49) L=2(F=1, B=1) M=-24(F=-12, B=-12) Job Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 22137 —HJ7A Diagonal Hip Girder 1 2 Job Reference (optional) East Coast Truss, FORT PIERCE, FL. 34946 7.250 s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:20:48 2011 Page 1 ID2ycEGXaGi5uaiv1 hsBRj37zPYdX rlq_gax3KsWmOG6ZWf81daZCPHoTwDV2FOALSyYUOz 1-6-9 3-3-10 3S II D Scale:1/2"=1' IC6 N 4x10 11 vn v 3380#/-6964# 3-6-9 25-7 0-7-3 , 3-3-10 2-9-15 9-10-13 Plate Offsets (X,Y): [B:0-2-4,0-2-01 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plateslncrease 1.25 TC 0.59 Vert(LL) -0.01 F-G >999 240 MT20 244/190 TCDL 7.0 Lumberincrease 1.25 BC 0.66 Vert(TL) -0.01 F-G >999 180 BCLL 0.0 * Rep Stress Incr NO WB 0.65 Horz(TL) 0.04 D n/a n/a BCDL 5.0 Code FBC2007/TPI2002 (Matrix-M) Weight: 129lb FT = 20% LUMBER BRACING TOP CHORD 2 X 6 SYP SS TOP CHORD BOT CHORD 2 X 6 SYP No.2 WEBS 2 X 4 SYP No.3 *Except* BOT CHORD W1:2X8SYP SS REACTIONS (lb/size) D=-87/Mechanical, F=-1638/Mechanical, G=2799/1-2-5 Max HorzG=340(LC 4) Max UpliftD=-105(LC 2), F=-1984(LC 2), G=-6964(LC 4) Max Grav D=242(LC 8), F=4069(LC 4), G=3380(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD B-C=-8637/4348 BOTCHORD B-G=-4273/8551,F-G=-3637/7366 WEBS C-F=-8172/4039,C-G=-3184/6492 Structural wood sheathing directly applied or 5-9-14 oc purlins, except end verticals. Rigid ceiling directly applied or6-0-0 oc bracing. NOTES 1) 2-ply truss to be connected together with 1 Od (0.131 "x3") nails as follows: Top chords connected as follows: 2 X 6 - 2 rows at 0-9-0 oc, 2 X 4 -1 row at 0-9-0 oc. Bottom chords connected as follows: 2 X 6 - 2 rows at 0-9-0 oc. Webs connected as follows: 2 X 4 -1 row at 0-9-0 oc, 2 X 8 - 2 rows at 0-9-0 oc. 2) AII loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Wind: ASCE 7-05; 150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable endzone; cantileverleft and (ghtexposed; Lumber DOL=1.60 plate grip DOL=1.60 4) 1nis truss has been designed forbasicload combinations, which include caseswith reductions for multiple concurrent liveloads. 5) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrentwith any other live loads. 6) * This truss has been designed fora live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 105 lb uplift atjoint D,1984 CoAjiklB&bti &_snd6964IbupliftatjointG. Job Truss Truss Type QtY Ply 22137-Klein, Ron -Klein Re -Roof 22137 —HPA Diagonal Hip Girder 1 2 Job Reference (optional) East Coast I russ, FUR I PIERCE, FL. 34946 7.250 s May 11 2011 MITek Industries, Inc. Fri Sep 30 10:20:48 2011 Page 2 ID:ZycEGXaGi5uaivlhsBRj37zPYdX rlq_qax3KsWmOG6ZWf8ldaZjCPHoTwDV2FOALSMOz NOTES 9)"Semi-rigid pitchbreaks including heels" Memberend fixity model was used in the analysis and design of this truss. 10) This truss has large uplift reaction(s) from gravity load case(s). Proper connection is required to secure truss against upward movement at the bearings. Building designer must provide for uplift reactions indicated. 11) Gap between inside of top chord bearing and first diagonal orvertical web shall not exceed 0.500in. 12) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 270 Ib down and 491 lb up at-2-9-15, and 270 Ib down and 491 lb up at-2-9-15 on top chord. The design/selection of such connection device(s) is the responsibility of others. LOADCASE(S) Standard 1) Regular: Lumberincrease=1.25,Plate lncrease=1.25 Concentrated Loads (lb) Vert: A=-445(F=-222, B=-222) Trapezoidal Loads(plf) Vert: A=0(F=22, B=22)-to-C=-104(F=-30, B=-30), C=0(F=22, B=22)4o-D=-33(F=6, B=6), H=0(F=5, B=5)-to-G=-24(F=-7, B=-7), G=0(F=5, B=5)-to-E=-8(F=1, B=1) Job Truss Truss Type QtY PIY 22137-Klein, Ron -Klein Re -Roof 22137 —HJ7B Diagonal Hip Girder 5 1 Job Reference (optional) East Coast Truss, FORT PIERCE, FL. 34946 7.250 s May 112011 MiTek Industries, Inc. Fri Sep 30 10:20:50 2011 Page 1 ID:ZycEGXaGi5uaivl hsBRj37zPYdX-ogy FGzKsTmUdaFye4AVi7e5dCySxvToVZtGQKyYUOx 2-9-15 5-1.4 4-9-9 Scale:)/2"=1' Camber =1/8 in 3x8 = 443#/-937# i , 9-10-13 i r 2-9-15 9-10-13 Plate Offsets (X Y): [F:0-4-12 0-1-8] LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plateslncrease 1.25 TC 0.47 Vert(LL) -0.18 F-I >638 240 MT20 244/190 TCDL 7.0 Lumberincrease 1.25 BC 0.65 Vert(TL) -0.31 F-1 >372 180 BCLL 0.0 ' Rep Stress Incr NO WB 0.34 Horz(TL) -0.02 F n/a n/a BCDL 5.0 Code FBC2007ITP12002 (Matrix-M) Weight: 53lb FT=20% LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD BOT CHORD 2 X 4 SYP No.2 WEBS 2 X 4 SYP No.3 BOT CHORD REACTIONS (lb/size) D=137/Mechanical, B=360/0-11-5, F=160/Mechanical Max HorzB=263(LC 4) Max UpliftD=-318(LC 4), B=-937(LC 4), F=-170(LC 7) Max Grav D=169(LC 2), B=443(LC 2), F=242(LC 3) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD B-C=-778/1025 BOT CHORD B-F=-1094/752 WEBS C-F=-764/1111 Structural wood sheathing directly applied or6-0-0 oc purlins. Rigid ceiling directly applied or5-11-4 ocbracing. MiTek recommends that Stabi I izers and required cross bracing be installed duringtruss erection, in accordancewith Stabilizer) nstallation guide. NOTES 1) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent liveloads. 3) This truss is not designed to support a ceiling and is not intended for use where aesthetics area consideration. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) "This truss has been designed for alive load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by Z-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 318lb uplift atjoint D, 937 lb uplift atjoint G and 170 lb uplift atjoint F. 8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. Continued on page 2 .:0 "D Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 22137 —HJ7B Diagonal Hip Girder 5 1 Job Reference (optional) East Coast I russ, FORT PIERCE, FL. 34946 7.250 s May 11 2011 MI Fek Industries, Inc. Fri Sep W 10:20:51 2011 Page 2 1, f ` ID:ZycEGXaGi5uaiv1hsBRj37zPYdX GtW/ScycnuLFkg8BohkFDBGNclhgMj)kDcgymyYUOw NOTES ` 9).Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 21 Ib up at 1-4-11, 21 Ib up at 1-4-11, 32 lb down and 29 lb up at 4-2-10, 32 lb down and 29 lb up at 4-2-10, and 38 lb down and 124 lb up at 7-0-9, and 38 lb down and 124 lb up at 7-0-9 on top chord, and 19 lb up at 1-4-11, 19 lb up at 1-4-11, 3 lb up at 4-2-10, 3 lb up at 4-2-10, and 39 lb down at 7-0-9, and 39 lb down at 7-0-9 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 1 Cj In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOADCASE(S) Standard 1) Regular: Lumber! ncrease=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert:A-D=-44, E-G=-10 Concentrated Loads (lb) Vert: H=43(F=21, B=21)1=38(F=19, B=19)J=5(F=2, B=2) K=-63(F=-31, B=-31) L=2(F=1, B=1) M=-26(F=-13, B=-13) Alb A Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 22137 -HJ7V DIAGONAL HIP GIRDER 2 1 Job Reference (optional East Coast Truss, FORT PIERCE, FL. 34946 7.250 s May 11 2011 MiTek Industries, Inc. Fri Sep 30 10:20:53 2011 Page 1 ID:ZycEGXaGi5uaiv1hsBRj37zPYdXCFettl?C8083U1 XJDjCKeGataLKBGgEBX5xlfyYU0u 2-9-15 4-9-11 5-1-2 A 3)0 = 480#/-949# 2.83 12 M = 1.41 12 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud TCLL 20.0 Plateslncrease 1.25 TC 0.60 Vert(LL) -0.20 F-I >591 240 TCDL 7.0 Lumberincrease 1.25 BC 0.70 Vert(TL) -0.36 F-1 >327 180 BCLL 0.0 * Rep Stress Incr NO WB 0.38 Horz(TL) -0.02 E n/a n/a BCDL 5.0 Code FBC2007/TPI2002 (Matrix-M) LUMBER BRACING . TOP CHORD 2 X 6 SYP No.2 TOP CHORD BOT CHORD 2 X 4 SYP No.2 WEBS 2 X 4 SYP No.3 BOT CHORD REACTIONS (lb/size) D=1 81 /Mechanical, B=395/0-10-3, E=144/Mechanical Max HorzB=351(LC 4) Max UpliftD=-416(LC 4), B=-949(LC 4), E=-174(LC 7) Max Grav D=220(LC 2), B=480(LC 2), E=216(LC 3) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD B-C=-1010/1445 BOTCHORD B-F=-1524/969 WEBS C-F=-959/1512 Scale=1:24.6 Camber = 3/16 in 34 = PLATES GRIP MT20 244/190 Weight: 54 lb FT = 20% Structural wood sheathing directly applied or 6-0-0 oc purlins. Rigid ceiling directly applied or5-0-7 oc bracing. MiTek recommends thatStabilizers and required cross bracing be installed during truss erection, in accordancewjth Stabilizerinstallation guide. NOTES 1) Wind: ASCE 7-05;150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat.11; Exp C; enclosed; MWFRS (low-rise) gable endzone; cantilever left and rightexposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed forbasicload combinations, which include caseswith reductions formultiple concurrent liveloads. 3) This truss has been designed fora 10.0 psf bottomchord live load nonconcurrentwith any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. ffi) Bearing atjoint(s) B considers parallel to grain value usingANSI/TPI 1 angle to grain formula. Building designershould verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 416 lb upliftatjoint D, 949 lb uplift atjoint G and 174 lb uplift atjoint E. .4) "Semi -rigid pitchbreaks including heels" Memberendfixity model was used in the analysis and design of this truss. Continued on page 2 Jib A Truss Truss Type Qty Ply 22137-Klein, Ron -Klein Re -Roof 122137 —HJ7V DIAGONAL HIP GIRDER 2 1 Job Reference (optional) East Coast I russ, FOR] PIERCE, FL. 34946 7.250 s May 11 ZU11 MI I eK Inaustnes, Inc. Fri Sep 3u 1 U:Lu:b3 ZU1'I rage Z ID:ZycEGXaGi5uaiv1hsBRj37zPYdX CFetd?C8083U1 XJDjCKeGatQ_K8GgEBX5xlfyYU0u NOTES ' 9)_Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 25 lb up at 1-4-11, 25 Ib up at 1-4-11, 26 lb down and 34 lb up at 4-2-10, 26 lb down and 34 lb up at 4-2-10, and 59 lb down and 169 lb up at 7-0-9, and 59 lb down and 169 lb up at 7-0-9 on top chord, and 2 lb up at 4-2-10, 2 lb up at 4-2-10, and 23 lb down and 7 lb up at 7-0-9, and 23 lb down and 7 lb up at 7-0-9 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 1 G) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASES) Standard 1) Regular: Lumberincrease=1.25, Plate I ncrease=1.25 Uniform Loads (plf) Vert: A-D=44, E-G=-10 Concentrated Loads (lb) Vert: C=7(F=3, B=3) H=50(F=25, B=25) J=-99(F=-49, 13=49) K=2(F=1, 13=1) L=-24(F=-12, B=-12) I FORM I 100A-08 +LORIDA ENERGY EFFICIENCY CODE FOR, BUILDING CONSTRUCTION Florida Department of Community Affairs -Residential Performance Method A Project Name: klein remodel Builder Name: Street: 5803 S Indian River Dr Permit Office: St Lucie County City, State, Zip: Fort Pierce, FI , Permit Number. Owner. Klein Remodel Jurisdiction: 661000 Design Location: FL, S-ILUCIE_CO_INTL 1.. New construction or existing Existing (Projecte 9. Wall Types (3496.6 sgfL) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.0 3496.60 W b. WA R= ft2 3. Number of units, if multiple family 1 c. N/A R= fN 4. Number of Bedrooms 3 d. WA R= ft= 5. Is this a worst case? No 10. Ceiling Types (2909.0 sqft.) Insulation Area 6. Conditioned floor area (W) 2909 a. Under Attic (Unvented) R=1.0 2909.00 ft= b. WA R= W 7. Windows(513.6 sgfL) Description Area c. N/A R= ftz a. U-Factor. Dbl, U=0.50 513.57 fig SHGC: SHGC=0.45 11. Ducts (combined) b. U-Factor: N/A fP a. Sup: Interior Ret: Interior AH: Interior Sup. R= 6, 600 fl? SHGC: 12. Cooling systems (combined) c. U-Factor. WA f12 a. Central Unit Cap: 62.8 kBtu/hr SHGC: SEER: 16 d. U-Factor. N/A ftz 13. Heating systems (combined) SHGC: a. Electric Heat Pump Cap: 62.8 kBtu/hr e. U-Factor. WA fP HSPF:8 SHGC: 14. Hot water systems 8. Floor Types (2909.0 sqft.) Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 2909.00 W EF: 0.95 b. N/A R= fP b. Conservation features c. N/A R= ft2 None 15. Credits Pstat Glass/Floor Area: 0.177 Total As -Built Modified Loads: 48.45 PASS Total Baseline Loads: 57.01 I hereby certify that the plans and specifications covered by Review of the plans and 1IE S7,47, this calculation are in compliance the Florida E specifications covered by this OF 1+ = a Code. calculation indicates compliance.,,, ''��' _ ',-,��� with the Florida Energy Code. =:a:.;; ,. PREPARED BY: _ - Before construction is completed r -- DATE: this building will be inspected for compliance with Section 553.908 ! _e a x � a - I hereby certify that this building, sig , is i compliance Florida Statutes. with the Florida Energy Code. Q01) yyE OWNER/AG NT- BUILDING OFFICIAL: - :DATE: ,e DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure a qualifies as certified factory -sealed in accordance with N1110.A.3. - Compliance requires an air distribution system test report, by a Florida Class 1 Rater, confirming system leakage to outdoors is not greater then 0 cfrn at 25 pascals pressure difference in accordance with N1110.A.2. -` Compliance requires an envelope leakage test report, by a Florida Class 1 Rater, in accordance with N1113.A.1. 7/16/2011 10:58 AM EnergyGauge® USA - FlaRes2008ILE Page 1 of 5 /) PROJECT Title: klein remodel Bedrooms: 3 Adress Type: Street Address Building Type: FLAsBuilt Conditioned Area: 2J09 Lot # Owner: Klein Remodel Total Stories: 1 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street 5803 S Indian River Dr Permit Office: St Lucie County Cross Ventilation: No County: St. Lucie Jurisdiction: 661000 Whole House Fan: No City, State, Zip: Fort Pierce, Family Type: Single-family Fl , New/Existing: Existing (Projected) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp % Winter Summer Degree Days Moisture Range Design Location TMY Site Zone 97.5 % 2.5 FL, ST LUCIE CO INTL FL_ST LUCIE_CO_INTL 2 39 90 75 70 722 58 Medium FLOORS # Floor Type Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio 302 ft 0 2909 ft2 0 0 1 ROOF Roof Gable Roof Solar Deck Color Absor. Tested Insul. Pitch # Type Materials Area Area 1 Gable or Shed Metal 2998 ft2 362 ft2 Unfinishe 0.96 No 22 14 deg ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2909 ft2 N N CEILING # Ceiling Type R Value Area Framing Frac Truss Type 1 Under Attic (Unvented) 1 70 ft2 0 Wood 2 Under Attic (Unvented) 1 1323 ft2 0 Woad 3 Under Attic (Unvented) 1 1193 ft2 0 Wood 4 Under Attic (Unvented) 1 323 ft2 0 Wood WALLS Cavity Sheathing Framing Solar # Omt Adjacent To Wall Type R Value Area R-Value Fraction Absor. 1 N Exterior Concrete Block - Int Insul 4 924.2 ft2 0 0 0.8 2 E Exterior Concrete Block - Int Insul 4 927.6 ft2 0 0 0.8 3 S Exterior Concrete Block - Int Insul 4 781.2 ft2 0 0 0.8 4 W Exterior Concrete Block - Int Insul 4 663.625 ft 0 0 0.8 4- 7/16/2011 10:58 AM I Ice - e1.,0—onno WINDOWS Orientation shown is the entered. asBult Qrientation. - Overhang # Omt Frame Panes NFRC U-Factor SHG1C Storms Area Depth Separation Int Shade Screening - 1 N Metal Double (Tinted) Yes 0.5 0.45 N 61.5 11? 0 ft 0 in 0 ft 0 in HERS 2006 None 2 N Metal Double (Tinted) Yes 0.5 0.45 N 19.27 ft2 0 ft 0 in 0 ft 0 in HERS 2006 None 3 N Metal Double (Tinted) Yes 0.5 0.45 N 27.2 ft2 0 ft 0 in 0 ft 0 in HERS 2006 None 4 N Metal Double (Tinted) Yes 0.5 0.45 N 9 ft2 0 ft 0 in Oft 0 in HERS 2006 None 5 N Metal Double (Timed) Yes 0.5 0.45 N 15 ft2 0 ft 0 in 0 ft 0 in HERS 2006 None 6 E Metal Double (Tinted) Yes 0.5 0.45 N 30 ft2 0 ft 0 in 0 ft 0 in HERS 2006 None 7 E Metal Double (Tinted) Yes 0.5 0.45 N 35.83 ft2 0 ft 0 in 0 ft 0 in HERS 2006 None 8 E Metal Double (Tinted) Yes 0.5 0.45 N 21 ft2 0 ft 0 in 0 ft 0 in HERS 2006 None 9 E Metal Double (Tinted) Yes 0.5 0,45 N 48 ft2 0 ft 0 in 0 ft 0 in HERS 2006 None 10 E Metal Double (Tinted) Yes 0.5 0.45 N 13.87 ft2 0 ft 0 in 0 ft 0 in HERS 2006 None 11 E Metal Double (Tinted) Yes 0.5 0.45 N 17.6 ft2 0 ft 0 in 0 ft 0 in HERS 2006 None 12 S Metal Double (Tinted) Yes 0.5 0.45 N 30 ft2 0 ft 0 in 0 ft 0 in HERS 2006 None 13 S Metal Double (Timed) Yes 0.5 0.45 N 24 ft2 0 ft 0 in 0 ft 0 in HERS 2006 None 14 S Metal Double (Tinted) Yes 0.5 0.45 N 17.92 ft2 0 ft 0 in 0 ft 0 in HERS 2006 None 15 S Metal Double (Tinted) Yes 0.5 0.45 N 11.47 ft2 0 ft 0 in 0 ft 0 in HERS 2006 None 16 S Metal Double (Tinted) Yes 0.5 0.45 N 6 ft2 1 ft 0 in 1 ft 0 in HERS 2006 None 17 W Metal Double (Tinted) Yes 0.5 0.45 N 20.4 ft2 0 ft 0 in 0 ft 0 in HERS 2006 None 18 W Metal Double (Tinted) Yes 0.5 0.45 N 30 ft2 2 ft 0 in 1 ft 0 in HERS 2006 None 19 W Metal Double (Tinted) Yes 0.5 0.45 N 40 ft2 2 ft 0 in 1 ft 0 in HERS 2006 None 20 W Metal Double (Tinted) Yes 0.5 0.45 N 27.33333 2 ft 0 in 1 ft 0 in HERS 2006 None 21 W Metal Double (Tinted) Yes 0.5 0.45 N 8.180555 2 ft 0 in 1 ft 0 in HERS 2006 None INFILTRATION & VENTING - Forced Ventilation - Run Time Supply CFM Exhaust CFM Fraction Fan Watts Method SLA CFM 50 ACH 50 ELA EgLA Proposed ACH(50) 0.00036 2747 7.08 150.8 283.6 0 cfm 0 elm 0 0 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Ducts 1 Central Unit Split SEER: 16 16.8 kBtu/hr cfm 0.75 sys#1 2 Central Unit Split SEER: 16 46 kBtu/hr cfrn 0.75 sys#2 HEATING SYSTEM # System Type Subtype Efficiency Capacity Ducts 1 Electric Heat Pump None HSPF: 8 16.8 kBtu/hr sys#1 2 Electric Heat Pump None HSPF: 8 46 kBtu/hr sys#2 7/16/2011 10:58 AM HOT WATER SYSTEM # System Type EF Cap Use SetPnt Conservation 1 Electric 0.95 5b gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS V -- Supply — — Return — Air Percent # Location R Value Area Location Area Leakage Type Handler CFM 25 Leakage QN RLF 1 Interior 6 250 ft2 Interior 50 ft Proposed Qn Interior 0.00 cfm 0.00 % 0.00 0.05 2 Interior 6 350 ft2 Interior 250 ft2 Proposed Qn Interior 0.00 cfm 0.00 % 0.00 0.05 TEMPERATURES Programable Thermostat Y Ceiling Fans: Cooling [X] Jan Heating [ ]X Jan Feb Mar Feb Mar [[XX]� LX] Apr Apr [[XX]] Ma [X� Jun Jui Ix] May [Xl Jun Jul [[XX�j Au [xl Aug [[XX]� Se [x] Sep Od [(XX�] Oct LXl Nov Nov ��XX� Dec . fX1 Dec Ventin [[�X]] Jan [[[���]]] Feb [[[��� Mar L[�Xll Apr [[�X]] May [[�X]] Jun [[[���]]] Jul [[�X]] Au [[�X1] Se [[[���]]] Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 7/16/2011 10.58 AM Fnamvrzmsinem r ice - cieo—wrw FORM 1100A-08 Code Compliance Checklist Residential'Whole Building Performance Method A - Details ADDRESS: 5803 S Indian River Dr PERMIT * M-d Fort Pierce, FI, a 0 � � l a INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows &_Doors N110_6.AB.1.1 Maximum:.3 cfm/s .ft. window area; .5 cfrn/ .ft. door area. J Exterior & Adjacent Walls — N1106.AB.1.2 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from, and is sealed to, the foundation to the top plate. Floors N1106.AB.1.2 Penetrations/openings > 1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings N1106.AB.1.2 Between walls & ceilings; penetrations of ceiling plane to top floor, around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier, gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams_-------- Recessed Lighting Fixtures _ N1106.AB.1.2 ---_.—.—�.__. Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC with < 2.0 cfm from conditioned space, tested. Multi -story Houses N1106.AB.1.2 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts N1106.AB.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters N1112.AB.3 Comply with efficiency requirements in Table N1112.ABC.3 Switch or clearly marked circuit breaker (electric) or cutoff (gas) must be provided. External or built-in heat trap required. _ Swimming Pools & Spas N1112.AB.2.3 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. Heat pump pool heaters shall have a minimum COP of 4.0. — — Shower heads N1112.AB.2.4 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems N1110.AB All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated and installed in accordance with the criteria of Section N1110.AB. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls N1107.AB.2 Separate readily accessible manual or automatic thermostat for each system. Insulation N1104.AB.1 Ceilings -Min. R-19. Common walls -frame R 11 or CBS R-3 both N1102.13.1.1 sides. Common ceiling & floors R-11. 7/16/20.11 10:58 AM EnergyGauge® USA - FlaRes2008 Page 5 of 5 ; / ENERGY PERFORMANCE LEVEL (EPL) DISPLAYCARD ESTIMATED ENERGY PERFORMANCE INDEX* = 85 The lower the EnergyPerformance Index, the more efficient the home. 5803 S Indian River Dr, Fort Pierce, FI, ;1. New construction or existing Existing (Projecte 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.0 3496.60 ft2 b. WA R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. WA R= ft2 5. Is this a worst case? No 10. Ceiling Types Insulation Area 6. conditioned floor area (ft2) 2909 a. Under Attic (Unvented) R=1.0 2909.00 ft2 b. WA R= ft2 7. Windows" Description Area c. WA R= ft2 a. U-Factor. Dbl, U=0.50 513.57 ft2 SHGC: SHGC--0.45 11. Ducts (combined) b. U-Factor. N/A ft2 a. Sup: Interior Ret: Interior AH: Interior Sup. R= 6, 600 fl2 SHGC: 12. Cooling systems (combined) c. U-Factor. N/A ft2 a. Central Unit Cap: 62.8 kBtu/hr SHGC: SEER: 16 d. U-Factor. WA ft2 13. Heating systems (combined) SHGC: a. Electric Heat Pump Cap: 62.8 kBtu/hr e. U-Factor. N/A ft2 HSPF:8 SHGC: 14. Hot water systems 8. Floor Types Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 2909.00 ft2 EF: 0.95 b. WA R= ft2 b. Conservation features c. WA R= ft2 None 15. Credits Pstat I :certify that this home has complied with the Construction through the abov er avir in this home before final ins n theryA based on installed Code m la f atyfF , lorida Energy Efficiency Code for Building features which will be installed (or exceeded) a new EPL Display Card will be completed Builder Signature: — Date: % �Bgall Address of New Home: .158o3 S, IAJd /f}vJ Rl" 6/2 City/FL Zip: 2 r2 `. prff9Cd y01I'V4 i�E ST7�0 'lift! A *Note: The home's estimated Energy Performance Index is only available through the EnergyGauge USA - FlaRes2008 computer program. This is not a Building Energy Rating. If your Index is below 100, your home may qualify for incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at (321) 638-1492 or see the Energy Gauge web site at energygauge.com for information and a list of certified Raters. For information about Florida's Energy Efficiency Code for Building Construction, contact the Department of Community Affairs at (850) 487-1824. **Label required by Section 13-104.4.5 of the Florida Building Code, Building, or Section B2.1.1 of Appendix G of the Florida Building Code, Residential, if not DEFAULT. EnergyGauge® USA - FlaRes2008 COPY s Project Summary Date: Jul 12, 2011 +P� wrightsoft° (Rest of House) By: Project Information For. Klein Remodel 5803 S Indian River Dr, Fort Pierce, FI Notes: Design • • Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 °F Outside db 90 OF Inside db 68 OF Inside db 75 OF Design TD 26 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 0 Btuh Structure 32854 Btuh Ducts 0 Btuh Ducts 6032 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 1707 Btuh Piping 0 Btuh Equipment load 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 38W3 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2909 Btuh Ducts 3494 Btuh Heating Cooling 2262 Central vent (0 cfm) Equipment latent load 0 6404 Btuh Btuh Area (ftl D Volume (M 0 25999 Air changes/hour 0 0.14 Equipment total load 44967 Btuh Equiv. AVF (cfm) 0 60 Req. total capacity at 0.70 SHR 4.6 ton Heating Equipment Summary Cooling Equipment Summary Make Trane Make Trane Trade XL161 WEATHERTRON Trade XL161 WEATHERTRON Model 4TWX6048E1 Cond 4T VX604BEl ARI ref no. 3943370 Coil 4TXAD064BC3+*UD2D120B9V5 ARI ref no. 3943370 Efficiency 8.5 HSPF Efficiency 12.0 EER, 16 SEER Heating input Sensible cooling 31850 Btuh Heating output 45500 Btuh @ 47OF Latent cooling 13650 Btuh Temperature rise 0 OF Total cooling 45500 Btuh Actual air flow 0 cfm Actual air flow 1517 cfm Air flow factor 0 cfm/Btuh Air flow factor 0.039 cfm/Btuh Static pressure 0 in H2O Static pressure 0.10 in H2O Space thermostat Load sensible heat ratio 0.86 Bokvda6c vahm have been mamsW ovefticlen Printout certified byACCA to meet all requirements of Manual J 8th Ed. -F4A- wrloht soft- Right-Suite®UnhmrsW 7.125 RSU06570 2011.1ul-1611:19;35 1 ACCK C:WserslWandaVeNdopMnual Mein remodel.rup Cate=NUB Orlenlabon =E .f. Page 1 Project Summary + wrightsoft unit two- Job: Date: Jul 12, 2011 By: r Project Information For. Klein Remodel, 5803 S Indian River Dr, Fort Pierce, FI WA Notes: FiLE COFY Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Outside db Inside db Design TD Heating Summary Summer Design Conditions 42 OF Outside db 68 OF Inside db 26 OF Design TD Daily range Relative humidity Moisture difference Structure 0 Btuh Ducts 0 Btuh vent (0 cfm) Humidification 0 Btuh Piping 0 Btuh Equipment load 0 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 Area ft Heating Cooling Volume fP) 0 8411 Air changes/hour 0 0.23 Equiv. AVF (cfm) 0 32 Heating EquipmentSummary Make Trane Trade XR15 WEATHERTRON Model 4TWR5018E1 ARI ref no. 4151201 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 8.5 HSPF 17900 Btuh @ 4rF 0 OF 0 cfm 0 cfm/Btuh 0 in H2O 90 OF 75 OF 1.5 OF L 50 % 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 7859 Btuh Ducts 1704 Btuh Central vent (0 cfm) 0 Btuh Blower 1707 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 10706 Btuh Latent Cooling Equipment Load Sizing Structure 1724 Btuh Ducts 997 Btuh Central vent (0 cfm) 0 Btuh Equipment latent load 2721 Btuh Equipment total load 13426 Btuh Req. total capacity at 0.70 SHR 1.3 ton Cooling Equipment Summary Make Trane Trade XR15 WEATHERTRON Cond 4TWR5018E1 Coil GAM5A0A18M11 ARI. ref no. 4151201. Efficiency 13.5 EER, 16.3 SEER Sensible cooling 12950 Btuh Latent cooling 5550 Btuh Total cooling 18500 Btuh Actual airflow 617 cfm Air flow factor 0.064 cfm/Btuh Static pressure 0.10 in H2O Load sensible heat ratio 0.81 B&dit&- vahresha" &-ePr=nwYyovenM*n Printout certified byACCA to meet all requirements of Manual J 8th Ed. !��+ �- - - wrigt�tsoTt Right-SulteO Universal 7.125 RSU06570 2011-.kit-1611:19�5 Aft C:1UwrMWandaM3eskopW=uatJWeinremodel:rup Cal:=MB Oriertation=E Page r r r I -- wrightsoft° Right-JO Worksheet d, (Rest of House) Job: Date: Jul 12, 2011 By: 1 Roam name (Rest of House) Exist bed 2-bath 2 EKied wall 209.0 ft 40.0 ft 3 l Ceiling height 11.5 ft 8 2 ft cool only 4 Room dimensions 1.0 x 334.0 ft 5 Room area 2262.0 ft2 334.0 f? Ty Construction U-value Or HTM Area Load Area number (Btuhlft"F) (Btuhlft� or perimeter (ft) (Btuh) (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross N/P!S Heat cool 6 13A-4ocs 0.143 n 0.00 Z55 417 301 0 765 0 0 0 0 10A-m 1.670 n 0.00 25.31 80 0 0 2037 0 0 0 0 1Dc2ow 0.570 n 0.W 20.29 36 0 0 735 0 0 0 0 VN L_G 13A-0ocs 0.143 a 0.00 2.55 759 610 0 1552 115 100 0 254 11 113-c2ow 0.570. a 0.00 62.36 149 0 0 9273 15 0 0 935 W 13A4ocs 1Dc2ow 0.143 s 0.00 2.55 482 422 0 1076 139 124 0 317 0.576 s 0.00 22.61 60 0 0 1356 15 0 0 339 W �L-�G 13A-4ocs Q743 w 0.00 2.55 633 516 0 1312 74 59 0 150 10A m 1.670 w 0.00 53.19 20 0 0 1085 0 0 0 0 1D-c2ow 0.570 w 0.00 62-36 97 0 0 6062 15 0 0 935 c 166-30ad 0.032 - 0.00 1.68 70 70 0 118 0 0 0 0 C 1BB38md 0.026 - 0.00 1.37 780 780 0 1065 0 0 0 0 c 16X19-0md 0.408 - 0.00 1.49 1089 1089 0. 1618 334 334 0 496 c 17A-20ad 0.043 - 0.00 1.40 323 323 0 461 0 0 0 0 F 22A tpl 0.989 - 0.00 0.00 2252 209 0 0 334 40 0 0 6 c) AED excursion 0 -316 Envelope loss/gain 0 28504 0 3111 12 a) infiltration 0 990 0 142 b) Room ventilation 0 0 0 0 13 . Internal gains: Occupants-(d 230- 2 460 1 230 Appliances/other .29001. 0 Subtotal.( lines.6.to.13). 0 32854 0 3483 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0. 0. 0. 14 15 Subtotal Duct taadS 0°/0 180/0 0 0 32854 6032 00/0 130A 0 0 3483 439 Total room load 0 38886 0 39221 Air required (cfm) 0 1517 0 153 153 Printout certified. by ACCA to meet all requirements of Manual J 8th Ed wroght-tom RjghE$ufta0 Unh ersa17.125 RSU06570 2011-Ju1-1611:19:35 / �� c:WserslWandaVesWpVMnualJUdeinremudelmp calc=MUB Orientation=E page-1- + - Wnghtsoft- Right,J® Worksheet (Rest of House) Job: Date: Jul 12, 2011 By: 1 Room name Great Room Existing living 2 Exposed wail 45.0 ft 45.0 ft 3 Cling height 13.0 ft only 16.0 ft only 4 Room dimensions 26.0 x 30.0coft 0 x 18.0cool ft 5 Roan area 780.0 ft' 468.0 ftz Ty Construction U-value Or HTM Area (ft2) Load Area (ftj Load number (Btuh/fP--°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross WP/S Heat Cool Gross WP1S Heat Cool 6 1qd 13A11ocs 0.143 n 0.00 255 208 140 0 356 160 131 0 332 10A•m 1.670 n 0.00 25.31 41 0 0 1033 20 0 0 516 ID-c2ow 0.570 n 0.00 20.29 27 0 0 552 9 0 0 183 16V 13A�4ocs 0.143 a 0.00 2.55 0 0 0 0 416 329 0 838 11 L-G ID-c2ow 0.670 a 0.00 62-36 0 0 0 0 87 0 0 6420 W 13A-4ocs 0.143 s 0.00 Z55 39 39 0 99 144 120 0 305 L-G ID-c2ow 0.670 s Q00 2281 0 0 0 0 24 0 0 543 1qJ 13A-4ocs 0.143 w 0.00 2.55 338 298 0 759 0 0 0 0 10A-m 1.670 w 0.00 63.19 0 0 0 0 0 0 0 0 If---GG 113-c2ow 0.670 w 0.00 62-36 40 0 0 2494 0 0 0 0 C 166-30ad 0.032 - 0.00. 1.68 0 0 0 0 0 0 0 0 C 166-38md 0.026 - 0.00 1.37 780 780 0 1065 0 0 0 0 C 16X19-0md 0.408 - 0.00 1.49 0 0 0 0 468 466 0 695 C 17A 20ad 0.043 - 0.00 1.40 0 0 0 0 0 0 0 0 F 22AV 0.989 - 0.00 0.00 780 45 0 0 468 45 0 0 6 c) AED excursion 217 -601 Envelope loss/gain 0 6575 0 8232 12 a) Inriltration 0 253 0 311 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 900 0 Subtotal (lines 6 to 13) 0 7728 0 8543 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 CO) 0 14 Subtotal 0 7728 0 8543 15 Dtrctloads 0% 33% 0 2554 0% 13% 1077 Total roam load 0 1028E 1 0 9620 Air required (cfm) 01 401 0 375 Printout certified bvACCA to meet all requirements of Manual J 8th Ed. - +- wrtgF°tsoTt RightSuit SWiverse17.125RSU06570 2011-Jul-1611:19'.35 .9�C O-Ww AWanda pWlanualJYdeinremodel.rup Calc=MJ6 Orientalmn=E Page2 - - wrightsoftc Right-M Worksheet (Rest of House) , Job: Date: Jul 12, 2011 By: 1 Room name existing Mchen Entry 2 Exposed wall 25.0 ft 14.0 ft 3 Ceiling height 8.2 ft cool only 8.2 ft cod only 4 Room dimensions 19.0 x 17.0 ft 14.0 x 5.0 ft 5 Room area 323.0 ft2 70.0 ft2 Ty Construction U-value Or HTM Area (fF) Load Area (ft) Load number (Btuhlft;°F) (Btuhlftj or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cod Gross N/P/S Heat Cod Grass WP/S Heat Cod 6lj�j13AAocs 0.143 n 0.00 2.55 49 30 0 76 0 0 0 0 10A-rn 1.670 n 0.00 25.31 19 0 0 488 0 0 0 0 1 D-c2ow 0.570 n 0.00 20.29 0 0 0 0 0 0 0 0 14J 13A-4ocs 0.143 a 0.00 Z55 156 124 0 316 0 0 0 0 11 T--G 1 D-c2ow 0.570 a 0.00 62.36 32 0 0 1982 0 0 0 0 134-4ocs 0.143 s 0.00 2.55 0 0 0 0 0 0 0 0 1 D-c2ow 0.570 s 0.00 22.61 0 0 0 0 0 0 0 0 -0 V,V 13AAocs 0.143 w 0.00 2.55 0 0 0 6 115 67 0 171 ��-GG 1QA-m 1.670 w 0.00 53.19 0 0 0 0 20 0 0 1085 ID-c2aw 0.570 w 0.00 62.36 0 0 0 0 27 0 0 1696 C 186-30ad 0.032 - 0.00 1.68 0 0 0 0 70 70 0 118 C 16B38md 0.026 - 0.00 1.37 0 0 0 0 0 0 0 0 C 16X19.0md 0.408 - 0.00, 1.49 0 0 0 0 0 0 0 0 C 17X20ad 0.043 - 0.00 1.40 323 323 0 451 0 0 0 0 F 22AV 0.989 - 0.00 0.00 323 25 0 0 70 14 0 0 61 c) AED excursion 352 896 Envelope loss/gain 0 2961 0 3966 12 a) Infiltration 0 89 0 50 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 2000 0 Subtotal (lines 6 to 13) 0 5050 0 4015 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 0 5050 0 4015 15 Duct loads 0% 13'/6 0 07 0% 13516 0 506 Total room load 0 5886 T 0 4522 Air required (cfm) 0 222 l I 0 176 Printout certified bvACCA to meet all requirements of Manual J 8th Ed _ - wrtgt�tsoTt Right SulttO Unh+ersal7.125 RSU06570 2011-Jul-1611:1925 . 1\ C,.UmrslWanda\DeskopWlanualJMeinrermdel.rup Calc=MJ8 Orientation=E Page F q 86ed 3 = uo0oluepo 9PW =Oleo dnrlaPowau upW ianuWAdomamep-mM si-M-0 � 9s:6L�LL9Linl`LLOZ OLS90rIS89ZL'LI !ufl�llnSi46Ri s+�s;v6e�M - fi-r •P3 439 P lenuew:o sVjawaj!nbw fie POW 04 VOOV q Pa AMO l IUM £9 0 L LL 0 (wp) paimbai xV OM 0 6£9Z 0 pM woo+ IeWl Zov 0 %££ 0/00 9L£ 0 o�o£L 0�00 spool pnO SL 9LZL 0 LZ9Z 0 MOVM bL 0 0 0 0 uowgppwu 0 0 0 0 jalwwl Ssal 0 0 0 0 Peol lewalxd seal 9LZL 0 LZSZ 0 (£L 0l 9 saup) IelownS 0 0 m WMrjueliddH 0 0 06Z L 0£Z sluedn300 :SUMB PWPA £L 0 0 0 0 uo1le1[ILMA wo0a (q L£ 0 96 0 -lle L4q (e ZL 99LL 0 96LZ 0 upOlssol adOlanu3 9t� LLL uaslrrixa cav (0 9 0 0 9 Oti 0 0 LZ LLZ 00'0 00 '0 - 696'0 Idi HZZ - 0 0 0 0 0 0 0 0 04'L 00'O - M'O 0 69 0 Ob Oir ZZ£ 0 LLZ LLZ 6VL 00"0 - 9040 Pw0-%X9L 0 0 0 0 0 0 0 0 0 L£'L 00'0 - 9Z0"0 Pw9£-Q% 0 0 0 0 0 0 0 0 0 991 00"0 - Z£0'O Pe0£-U% 0 0 0 0 0 9£6 0 0 SL 9£79 00'0 M OLS"0 AWZO-OL ° --I c 0 0 0 0 0 0 0 0 U'£9 00"O M OL9.0 0 0 0 0 E£Z 0 Z6 LOL 96z 00"0 sOO6-H£L NiA 0 0 0 0 6££ 0 0 9L L9zZ 00'0 s OLS'O MOZO-OL 0 0 0 0 49Z 0 OOL 94 95z 00"0 S £VL"0 L 9£6 0 0 SL 0 0 0 0 9£79 00'0 a OL9'0 mzo-ai L L 461 0 LS ZL 0 0 0 0 99z 00"0 a £HL'O SOO6�d£L 191 " 0 0 0 0 0 0 0 0 6Z"OZ 00'0 u 01S'0 mozo-M 0 0 0 0 0 0 0 0 L£"9Z 00'0 u OL91 w-'VOL 0 0 0 0 0 0 0 0 99z 000 u £CL"0 sootlwL . 9 1003 WaH SMIN sm* POO leaH SMIN sswS POO MR (Ae AAMO jagwnu (4ni8) (B) japupad jo (4018) (B) slawuad 1O (.BMnlB) Peol (=B) ew PMI (Zu) ew VUH j0 amen-n UORMlS000 Fl z8 0'Ob zil O'LLZ ears UMOU 9 u D'S X 0'8 u 0"LLZ x 0"L suolsuawp woos 6ufleo q Ajuo fm B 0"6 Nuo pw B Zl; 1461a4 £ u O'9 B O"LZ 1pm Pasodx3 Z Z 4m 4MCK Paq AM aweu woos L :Ae LLoZ'ZL Inr -ele0 :qor (asnoH jo;say) ;says)IJoM ®P-ItIBIN s�y6�ann + w' dghtsoft° Right-J® Worksheet (Rest of House) Job: Date: Jul 12, 2011 By: 1 2 3 4 5 Room name Exposed wall Ceiling height Room dimens�orrs Room area bath 1 5.0 ft 9.0 ft cad Doty 6.0 x 5.0 ft 30.0 ft2 Ty Constnrction number U-value (Btuh/f =°F) Or HTM (Bt Area (ft- or perimeter (ft) Load p3tuh) Area or perimeter Load Heat Cod I Gross WP/S Heat Cod Gross WP/S Heat Cod 6 11 l j 1{--- f�` 13A-4ocs 10A-m ID-c2ow 13A-4ocs 1D-c2ow 13A-40ts 1D-c2ow 13A40cs 10A-m 1Dc2ow 166.30ad 161338md 0.143 1.670: 0.570 0.143 0.570 0143 0.570 0.143 1.670 0.570 0.032 0.026 n n n a a s s w w w - - 0.00 a00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 2.55 25.31 20.29 2.55 62.36 2-55 22.61 2.55 53.19 62-36 1.68 1.37 0 0 0 0 0 45 6 0 0 0 0 0 0 0 0 0 0 39 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0' 0 0 99' 136 0 0 0 0 0 y,� L--G W L- G C C C 16X19-0md 0.408 - 0.00 1.49 30 30 0 45 C F 17A-20ad m4pl 0.043 0.989 - - 0.00 0.00 1.40 0.00 0 30 0 5 0 0 0 0 6 c) AED excursion -1 Envelope loss/gain 0 278 12 a) Infiltnition 0 19 b) Room ventilation 0 0 13 Internal gains: Occupants Q 230 0 0 Applianoes/other 0 Subtotal pines 6 to 13) 0 298 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 0 298 15 Duct loads 0% 33% 0 98 Total room load 0 396 Air required (cfrn) 0 15 Printout certified byACCA to meet all requirements of Manual J 8th Ed. _ -- wri9f.tsorrt- Right-Sub9Universa17.125RSU06570 2011-&r1-1611:19:35 �� C:Wsers%WandaV)esidopMenual.Weemremodel.rup Calc-M,18 Orientation=E Page / + - wrightsofr Right,J® Worksheet Job: Unit two Date: Jul 12, 2011 � By: 1 Room name unit two Existing master 2 Exposed wall 93.0 ft 72.0 ft 3 4 Ceiling height Room dimensions 13.0 ft 1&0 ft cool only 1.0 x 543.0 ft 5 Room area 647.0 ft' 643.0 ft2 Ty Construction number tJ value (Btuhlftk"F) Or HTiU (BtutUft2) Area (ft-) or perimeter (ft) Load (Btuh) Area (ftj or perimeter (ft) Load (Btuh) Heat Cool Gross NIP/S Heat Cool Gross PUP/S Heat Cool 6 11 13A-4ocs 10A-m ID-c2ow 13A-4ocs 1D-c2ow 13A-4ocs ID-c2ow 13A40cs 10A-rn ID-c2ow 1613-30ad 0.143 1.670 0.570 0.143 0.670 0.143 0.670 0.143 1.670 0.570 0.032 n n n a a s s w w w - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Z55 0.00 20.29 255 6236 Z55 22-61 Z65 0.00 62.36 0.00 507 0 15 169 18 299 29 234 0 8 0 492 0 0 151 0 270 0 226 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1252 0 304 385 1098 686 664 575 0 516 0 403 0 15 0 0 299 29 234 0 8 0 388 0 0 0 0 270 0 226 0 0 0 0 0 0 0 0 0 0 0 0 0 0 988 0 304 0 0 686 664 575 0 516 0 I---G G 1�N l_-C W L-C C C 16B Mmd 0.026 - 0.00 1.37 543 543 0 741 543 543 0 741 C 16X19-0md 0.408 - 0.00 1.49 104 104 0 155 0 0 0 0 C 17A-20ad 0.043 - 0.00 0.00 0 0 0 0 0 0 0 0 F 22A tpl 0.989 - 0.00 0.00 647 93 0 0 543 72 0 0 6 c) AED excursion 0 -127 Envelope toss/gain 0 6376 0 4346 12 a) infiltration 0 522 0 405 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 2 460 Appliancesiother 500 5W Subtotal (lines 6 to 13) 0 5711 Less external load 0 0 Less transfer U 0 0 Redistribution 0 0 14 Subtotal 0 5711 15 Duct loads Oa/a 22% 0a/0 15a/a 0 842 Total room load 0 9563 0 6553 Air required (cfm) 0 617 0 423 Printout certified bvACCA to meet all requirements of Manual J 8th Ed. -1'F+- wrigF�tsoTr- RightSuiteO Liniversal7.1.25 RSU06570 2011-.kd-1611:19:35 . MserslWendaVesldopWlanual Mein renmdel rup Cale= MIS Orlentation = E Page 6 L Job: +p- vvnghtsoft° Right-J® Worksheet Date: Jul 12, 2011 unit two - By: 1 Room name mstr bath 2 Exposed wall 21.0 ft 3 Ceiling hergM 13.0 ft cool only 4 Room dimensions 13.0 x 8.0 It 5 Room area 104.0 ft2 Ty Construction number U-value (Btuh/ft? oF) Or HTM (Btuhlftj Area (ft� or perimeter (ft) Load (Btuh) Area or perimeter Load Heat cool Gross N/P/S Heat cool Gross NIP/S Heat Cool 6 VJJ iL--CG 13A-1ocs 0.143 n 0.00 2.55 104 104, 0 265 10A-m 1.670 n 0.00 0.00 0 0 0 0 ID-c2ow 0.670 n 0.00 20.29 0 0 0 0 VN 13A-4ocs 0.143 a 0.00 2.55 169 151 0 385 11 t--G ID-c2ow 0.570 a 0.00 62.36 18 0 0 1098 V�J 13A-4ocs 0.143 s 0.00 7-55 0 0 0 0 t-G 1D-c2o6V 0.570 s 0.00 22.61 0 0 0 0 Vdl 13A-4ocs 0.143 w 0.00 Z55 0 0 0 0 --G 10A-m 1.670 w 0.00 0.00 0 0 0 0 1D-c2ow 0.570 w 0.00 67-36 0 0 0 0 c 16B-30dd 0.032 - 0.00 0.00 0 0 0 0 c 166.38md 0.026 - 0.00 1.37 0 0 0 0 c 16X19-0md 0.408 - 0.00 1.49 104 104 0 155 c 17X20ad 0.043 - 0.00 0.00 0 0 0 0 F 22A tpl 0.989 - 0.00 0.00 104 21 0 0 6 c) AED excursion 127 Envelope loss/gain 0 2030 12 a) Intfiftration 0 118 b) Room ventilation 0 0 13 Intemal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal (fates 6 to 13) 0 2148 Less extemal load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 0 2148 15 Duct loads 00 40% 0 862 Total room Iced 0 3010 Air required (cfm) 0 194 Printout certified byACCA to meet all requirements of Manual J 8th Ed. -Fed- writgF�tsoTt- Right-Surb@ Unhtersal7.125 RSU06570 2011-Jul-1611:19:35 �� C:WserslWandalDesidopWlanualJWelnrerrodellup Calc=MJB Orientation=E Page7 Sheet 1 Job #: Performed for: Klein Remodel 5803 S Indian River Dr Fort Pierre, FI Scale: 1 : 138 Page 1 Right-SUW Universal 7.1.25 RSU06570 2011-Jul-1611:19.46 ...sktopWlanual Aklein remodel.rup Important Notic : If visually graded lumber is used for the trusses covered by these designs, sbe "SPIB Important Notice, Dated July 28, 2010" (reprinted at www.mii.com) before use. MiTek does not warrant third -party lumber design values. POWER TO PERFORM.- RE: 22137 - 22137 - KLEIN, RON - KLEIN RE -ROOF MiTek Industries, Inc. 1 6904 Parke East Blvd. Site Information: Tampa, F1n33 0~ 1 Customer Info: Klein, Ron Project Name: Klein Re -Roof Model: Lot/Block: Subdivision: !� I Address: 5803 S. Indian River Drive co?l City: Ft. Pierce State: FL Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: State: General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2007/TP12002 Design Program: MiTek 20/20 7.3 Wind Code: ASCE 7-05 Wind Speed: 150 mph Floor Load: N/A psf Roof Load: 32.0 psf This package includes 40 individual, dated Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61 G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. No. I Seal# I Truss Name I Date No. I Seal# Truss Name I Date 1 IT4055651 -CJ1 4/18/011 118 IT4055668 I A05G 4/18/011 12 I T4055652 I --CJ 1 A 14/18/011 119 I T4055669 I A06 14/18/011 I 13 I T4055653 I -CJ3 14/18/011 120 I T4055670 I A07 14/18/011 1 14 IT4055654 I-CJ3A 14/18/011 121 IT4055671 I B01 14/18/011 1 15 I T4055655 I --CJ3S 14/18/011 122 I T4055672 I B02 14/18/011 I 16 I T4055656 I -CJ5 14/18/011 123 I T4055673 I B03G 14/18/011 I 17 I T4055657 I -CJ5A 14/18/011 124 I T4055674 I B04G 14/18/011 I 18 I T4055658 I -CJ5S 14/18/011 125 I T4055675 I C01 14/18/011 1 19 I T4055659 I -EJ7 14/18/011 126 I T4055676 I CO2 14/18/011 I 110 I T4055660 I -EJ7S 14/18/011 127 I T4055677 I CO3 14/18/011 I 111 I T4055661 I -HJ7 14/18/011 128 I T4055678 I C04G 4/18/011 112 I T4055662 I --HJ7A 14/18/011 129 I T4055679 I D01 14/18/011 1 113 I T4055663 I -HJ7S 14/18/011 130 I T4055680 I D02 14/18/011 I 114 I T4055664 I A01 14/18/011 131 I T4055681 I D03 14/18/011 I 115 I T4055665 I A02G 14/18/011 132 I T4055682 I D04G 14/18/011 I 116 I T4055666 I A03 14/18/011 133 I T4055683 I E01 G 14/18/011 117 IT4055667 IA04 14/18/011 134 IT4055684 I E02 14/18/011 The truss drawing(s) referenced above have been prepared by MiTek Industries, Inc. under my direct supervision based on the parameters ;vided by East Coast Truss. f Design Engineer's Name: Velez, Joaquin Anse renewal date for the state of Florida is February 28, 2013 j f N,, ig: The seal on these drawings indicate acceptance of professional engineering responsibility solely for the truss components shown. The suitability and use of this component _ for any particular building is the responsibility of the building designer, per ANSI/TPI-1 Sec. 2. % QU I N VF o� � .•��G NSF•.c�'�. o No 681_82 �13 STATE''OF `•�� • '<v. SOT A� P.•��.` FL Cert. 6634 April 18,2011 Velez, Joaquin 1 of 2 r RE: 22137 - 22137 - KLEIN, RON - KLEIN RE -ROOF Site Information: Customer Info: Klein, Ron Project Name: Klein Re -Roof Model: Lot/Block: Subdivision: Address: 5803 S. Indian River Drive City: Ft. Pierce State: FL No. I Seal# Truss Name Date �35 IT4055685 E03G 4/18/011 136 IT4055686 I FG01 14/18/011 1 137 IT4055687 I FG02 14/18/011 1 138 IT4055688 I MV5 14/18/011 1 139 IT4055689 I MV7 14/18/011 140 IT4055690 I MV9 14/18/011 2 of 2 ma Job russ Truss Type Qty Ply 22137 - KLEIN. RON - KLEIN RE -ROOF T4055651 22137 1-1 Jack -Open Truss 24 1 Job Refere ce o tlo a East Coast Truss, FORT PIERCE, FL. 34946 7.250 s Jan 28 2011 MiTek Industries, Inc. Mon Apr 18 14:45:58 2011 Page 1 ID:ZycEGXaGi5uaivlhsBRj37zPYdX-s6vdwGu — C?tU??_gQWiSPhGK9tl715ZC4?DihQzPTAN " -2-0-0 1-0-0 2-0-0 1-0-0 Refer to MITek "TOE -NAIL" Detail for connection to Scale = 1:6.5 supporting carrier truss (typ all applicable jacks on this job) 3 4 2 d a 1 N d >< 6 7 3x4 = 1-0-0 1-0-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) VdeN L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.55 Vert(ILL) -0.00 2 >999 240 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.08 Verl(Q -0.00 2 -999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TQ 0.00 3 Na n/a BCDL 5.0 Code FBC2007ITP12002 (Matrix) Weight: 6 lb FT = 20% LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10.0.0 oc bracing. Fek recommends that Stabilizers and required cross bracing be installed during ss erection in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 2=229/0.6-0 (min. 0-1-8), 3=-96/Mechanical, 6=6/Mechanical Max Horz 2=94(LC 4) Max Uplift2=-704(LC 4), 3=-118(LC 2) Max Grav 2=280(LC 2), 3=317(LC 4), 6=206(LC 12) FORCES (Ib) -max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown. NOTES 1) Wind: ASCE 7-05; 150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. 11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 2) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 704 lb uplift at joint 2 and 118 lb uplift atjoint 3. 7) This truss has been designed for a moving concentrated load of 200.Olb live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. 8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard GO N vF 0 + N 68182 ' . T O F + '!4 O�.• + ttit FL Cert. 6634 April 18,201 WARNING - 7.Hfy design P--tmn and READ NOTES ON TTT/S AND INCLUDED MI9P-K REFERENCE PAGE MII.7473 rev. 10-'08 BEFORE USE. — Design valid for use only with MOek connectors. This design is based only upon parameters shown, and is for an individual building component. ■■AYE Applicability of design paramenters and proper Incorporation of component is responsibility of building designer- not truss designer. Bracing shown is for lateral support of individual web members any. Additional temporary bracing to insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding MiTek• fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII qualtty Criteria, DSE-89 and BCSI Bullding Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610-4115 Job 22137 East Coast 1 TRUSS 12 1 1 22137 - KLEIN, RON - KLEIN RE -ROOF 7.250 s Jan 28 2011 -2-0-0 1-2-0 2-0-0 1-2-0 T4055652 1 Scale = 1:6. r- us d LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 5.0 SPACING 2-0-0 Plates Increase 1.25 Lumber Increase 1.25 Rep Stress Incr YES Code FBC2007RPI2002 CSI TC 0.72 BC 0.91 WB 0.00 (Matrix) DEFL in (too) Well L/d Vert(LL) 0.00 2 n/r 120 Vert(TL) -0.02 2 n/r 120 Horz(TL) 0.00 We Na PLATES GRIP MT20 244/190 Weight: 7Ito FT=20% LUMBER BRACING TOP CHORD 2 X 4 SYP SS TOP CHORD Structural wood sheathing directly applied or 1-2-0 oc purlins. BOT CHORD 2 X 4 SYP No.1 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during Wss erection in accordance with Stabilizer Installation guide. REACTIONS(lb/size) 4=150/Mechanical 3=0/Mechanicat Max Uplift4=-461(LC 4) Max Grav 4=256(LC 13) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1353/582 BOT CHORD 2-5=-632/1562, 4-5=-632/1562 NOTES 1) Wind: ASCE 7-05; 150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cal. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and - right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 451 lb uplift at joint 4. 7) This truss has been designed for a moving concentrated load of 200.01b live located at all mid panels and at all panel points along the Bottom Chord, live loads. nonconcurrent with any other 8) "Semi -rigid pilchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard ,,`,�0 �,•\G E•N si�,`� �♦ J I♦ N 68182 ,I T O'. C? "%% FL Cert. 6634 April 18,201 WARNING •Verify doign p-wntaiers and RMD NOTES ON THIS AND INCLUDED 119MREFBRENCE PAGE M -747J '-- ZO•'08 BEFORE USE, a Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. HT 1 Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individuol web members ony. Additional temporary bracing to insure stability during construction is the responsibillity of the MiTek' erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding Po e ro •. r fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute. 781 N. Lee Street. Suite 312, Alexandria, VA 22314. Tampa, FL 33610.4115 Job Truss Truss Type Qty Ply 22137 - KLEIN, RON - KLEIN RE -ROOF T4055653 22137 -CJ3 Jack -Open Truss 16 1 Jobb a erence a tional East Coast Truss, FORT PIERCE, FL. 34946 7.250 s Jan 28 2011 MITek Industries, Inc. Mon Apr 18 14:46:00 2011 Page 1 ID:ZycEGXaGi5uaivl hsBRj37zPYdX-pV00LxwFkc7CE 17DYxkwU6Mj8hNiV72VYJipm lzPTAL - -2-0-0 3-0-0 2-0-0 3-0-0 ` Scale = 1:9.4 - 3 2 u: I 1 5 4 3x4 = 3-0-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deg Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.33 Vert(LL) -0.01 2-4 -999 240 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.26 Vert(TL) -0.02 2-4 >999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 Na n/a BCDL 5.0 Code FBC2007frP12002 (Matrix) Weight: 17 lb FT=20% LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. that Stabilizers and required cross bracing be installed during trussrecommends truss erection in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 3=11/Mechanical, 2=219/0-8-0 (min. 0-1-8), 4=13/Mechanical Max Harz 2=150(LC 4) Max Uplift 3=42(1_C 7), 2=-594(LC 4) Max Grav 3=26(LC 8). 2=279(LC 12), 4=213(LC 13) FORCES (lb) -Max. Comp:/Max. Ten. -All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-05; 150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft Cat 11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 2) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 42 lb uplift atjoint 3 and 594 lb uplift at joint 2. 7) This truss has been designed for a moving concentrated load of 200.01b live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. 8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. a rrrl,�� LOAD CASE(S) Standard `"1111i •�PQU I N VF� • ENB•����. N 68182 �44/� ;% :��• T v .o O �• C? . FL Cert. 6634 April 18,201 ® VIARMNO-Verify d vign pa, a d.. and READ N07ES ON THIS AIW INCLUDED WII REFERL'NCS PAGE MI-7473 rr . 20-'08 BEFORE USE. Design valid for use only with Miiek connectors. This design is based only upon parameters shown, and is for an individual building component. ��• Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the M iTek' erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing. consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610.4115 Type Qty I Ply 122137 - KLEIN, RON - KLEIN RE -ROOF T4055654 CJ3A Jack -Open Truss 2 1 i Job Reference (optional) ERCE. FL. 34946 7.250 s Jan 28 2011 MiTek Industries, Inc. Mon Apr 18 14:46:00 2011 Page 1 ID:ZycEGXaGi5uaivl hsBRj37zPYdX-pV00LxwFkc7C E17DYxkwU6MkHhKN?2VYJipm IzPTAL -2-0-0 3-0-0 2-0-0 3-0-0 Provide bearing connection(s) to resist horizontal reaction(s) shown. Failure to 3 Scale = 1:9.61 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 ' BCDL 5.0 SPACING 2-0-0 Plates Increase 1.25 Lumber Increase 1.25 Rep Stress Incr YES Code FBC2007/rP12002 CSI TC 0.26 BC 0.45 WB 0.00 (Matrix) DEFL in Vert(LL) 0.00 Vert(TL) -0.01 Horz(TL) 0.00 (loc) Udefl L/d 2 n/r 120 2 Nr 120 n/a Na PLATES GRIP MT20 244/190 Weight: 17 lb FT = 20% LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-0.0 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection in accordance with Stabilizer Installation quida. REACTIONS(lb/size) 3=232/Mechanical 4=15/Mechanical Max Harz 3=2074(LC 4). 4=2225(LC 4) Max Uplift 3=655(1_C 4), 4=-77(LC 4) Max Grav 3=284(LC 12), 4=215(LC 13) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2182/988 BOT CHORD 2-5=-948/2225, 4-5=-948/2225 NOTES 1) Wind: ASCE 7-05; 150mph (3-second gust); TCDL=4.2psf; BCDL=3.0psf; h=18ft; Cat. 11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) This truss has been designed for basic load combinations, which include rases with reductions for multiple concurrent live loads. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6.0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 655 lb uplift at joint 3 and 77 lb uplift at joint 4. 7) na 8) This truss has been designed for a moving concentrated load of 200.0Ib live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. 9) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard ® WARMNG - Ve h d®iyn pn tmw and READ N07ES ON 77I1S AND INCLUDED 9BTBKREFBRENCS PAGB MU 7473 — I0-'08 BEFORE USE. Design valid for use only with M1ek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design paramenters and proper incorporation of component Is responsibility of building designer- not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity, of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control. storage, delivery, erection and bracing, consult ANSI/iPll Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314. `Illllllll/��� %OPQV I N VE�, I I N 68182 :�•• T OF /lnnll�`� FL Cert. 6634 April 18,201 my MiTek' 6904 Parke East Blvd. Tampa, FL 33610.4115 rw Job Truss Truss Type Oty Ply 22137 - KLEIN, RON - KLEIN RE -ROOF T4055655 22137 -CJ3S JACK -OPEN TRUSS 6 1 Job stare ce o Ilona East Coast Truss, FORT PIERCE, FL. 34946 7.250 s Jan 28 2011 MiTek Industries, Inc. Mon Apr 18 14:46:01 2011 Page 1 _ ID:ZycEGXaGi5uaivl hsBRj37zPYdX-HhamZHwlVwF3sSiP6eF90Kurh5mXES IemzRMI IzPTAK -2-0-0 0-9-4 3-0-0 2-0-0 0-9.4 2-2-12 Scale = 1:13.5 3 5x10 = 2 N O 4 d 1 N a 6 4 a 7 2x4 11 5 Plate Offsets X 2:0-3-4 D-2-8 LOADING (psf) SPACING 2-0-0 CSI DEFL in (too) Ildefl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.54 Vert(LL) -0.01 4-5 >999 240 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.10 Vert(TL) -0.01 4-5 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.01 4 n/a Na BCDL 5.0 Code FBC2007/TP12002 (Matrix) Weight: 19 lb FT=20% LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins, except end verticals. BOT CHORD 2 X 4 SYP SS BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2 X 4 SYP No.2 MiTek recommends that Stabilizers and required cross bracing be installed during OTHERS 2 X 10 SYP No.2 truss erection in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 3=16/Mechanical, 4=8/Mechanical, 7=214/0-8-0 (min. 0-1-8) Max Harz 7=165(LC 4) Max Uplift3=44(LC 7), 7=-609(LC 4) Max Grav 3=47(LC 12), 4=209(LC 13), 7=261(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-05; 150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cal 11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 2) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Bearing at joint(s) 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 44 lb uplift atjoint 3 and 609 lb uplift atjoint 7. 8) This truss has been designed for a moving concentrated load of 200.0Ib live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. 1 1 1� I �r� 1 I V V�� 9) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard ISO NS�.,� ��� :♦ �.��Ci•E i N 68182 T OF FL Cert. 6634 April 18,201 ® W6RNINO - Verify d�iynparn dmt and READ NO7ES ON THIS AND INCLUDED W PKREPERENCB PAOB IW-7473 rw. Z0`08 BEFORE USE. Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. ■■■��•iii�ii Applicability of design paramenters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability durinconstruction is the responsibillity, of the erector. Additional bracing of the overalgl structure is the responsibiGly of the building designer. or general guidance regarding MiTek' permanent fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality CrNeria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610-4115 Jab Truss Truss Type Qly Ply 22137 - KLEIN, RON - KLEIN RE -ROOF T4055656 22137 -CJ5 Jack -Open Truss 17 1 Jo a erence o tional East Coast Truss, FORT PIERCE, FL. 34946 7.250 s Jan 28 2011 MiTek Industries, Inc. Mon Apr 18 14:46:01 2011 Page 1 ID:ZycEGXaGi5uaivl hsBRj37zPYdX-HhamZHwtVwF3sSiP6eF90Kuuu5gRESlemzRMIIzPTAK -2-0-0 5-0-0 2_0.0 5-0-0 - Scale = 1:13.3 3 2- 5 4 3x4 = 5-0-0 5-0-0 LOADING (psf) SPACING 2.0-0 CSI DEFL in (too) Vdett L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.33 Vert(LL) -0.08 2-4 >674 240 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.49 Vert(TL) -0.10 2-4 >554 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a Na BCDL 5.0 Code FBC2007ITP12002 (Matrix) Weight: 25 to FT = 20% LUMBER BRACING TOP CHORD 2 X 6 SYP N0.2 TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. _ MiTek recommends that Stabilizers and required cross bracing be installed during truss erection in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 3=75/Mechanical, 2=253/0-8-0 (min. 0-1-8), 4=23/Mechanical Max Harz 2=204(LC 4) Max Uplift 3=164(LC 4), 2=-614(LC 4) Max Grav 3=92(LC 2). 2=305(LC 2), 4=223(LC 13) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-05; 150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. 11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 4) Gable studs spaced at 2-0-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 164 lb uplift at joint 3 and 614 lb uplift at joint 2. at all along the Bottom Chord, 9) This truss has been designed for a moving concentrated load of 200.01b live located at all mid panels and panel points nonconcurrent with any other live loads. % U 1 N V F4� 10) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. • , • • • / , LOAD CASE(S) Standard ,,%�OAQ• • • �GENS•' � �' , '•,• , ; N 68182 �-0 41 ��nnllll FL Cert. 6634 April 18,201 ® WARMNG - Vesify design p-in to and READ N07M ON 79IIS AND INCLUDED 1477RKREFERP-NCB PAGB 6II7.7a73 rcv. 20-VS BBFOBB USE. *' Design valid for use only with MTek connectors. This design is based onty upon parameters shown, and is for an individual building component. i•�i■i Applicability of design paramenters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown is for lateral support of individual web members onN• Additional temporary bracing to insure stability during construction is the respomibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding MiTek' ow m v.a.on.a fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Citterla, DSB-89 and BCSI Building Component 69D4 Parke East Blvd. Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610-4115 Fn Job Truss Truss Type Oty Ply 22137 - KLEIN, RON - KLEIN RE -ROOF T4055657 22137 -CJSA Jack -Open Truss 1 1 Job a ere ce o tional East Coast Truss, FORT PIERCE, FL. 34946 1.250 s Jan 28 2011 MiTek Industries, Inc. Mon Apr 1 B 14:46:02 2011 Page 1 ID:ZycEGXaGiSuaivl hsB Rj37zPYdX-1188mdxVGENwTcHbfLmOZXR4gUyyzvYn7dBwgBzPTAJ -2-0-0 5-0-0 2-0-0 5-0-0 Scale = 1:13.5 Provide bearing connection(s) to resist - horizontal reaction(s) shown. Failure to do so voids this design. U 3 2 N 1 3x6 = 5 4 5-0-0 5-0-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/de8 Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.27 Vert(LL) 0.00 2 Nr 120 MT20 2441190 TCDL 7.0 Lumber Increase 1.25 BC 0.73 Vert(TL) -0.04 2-4 Nr 120 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 Na Na BCDL 5.0 Code FBC20071TPI2002 (Matrix) Weight: 251b FT=20% LUMBER BRACING - TOP CHORD 2 X 6 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 4-6-12 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 5-9.9 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection in accordance with Stabilizer Installation guide. REACTIONS(lb/size) 3=330/Mechanical 4=25/Mechanical a o 3=2575 LC 4 4=277 4 Max Uplift 3=907(LC 4), 4=-130(LC 4) Max Gray 3=399(LC 2), 4=225(LC 13) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2734/1120 BOT CHORD 2-5=-1075/2779, 4-5=-1075/2779 NOTES 1) Wind: ASCE 7-05; 150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf, h=18ft; Cal II; Grp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 907 lb uplift at joint 3 and 130 lb uplift at joint 4. 7) na 8) This truss has been designed for a moving concentrated load of 200.O1b live located at all mid panels and at all panel points along the Bottom Chord, nonconcument with any other live loads. `�� U 1 N 9) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard , .f•��!✓•E•N S`C '•�,'�� :� i N 68182 : � = - 3O�. T O F ;0. o � FL Cert. 6634 April 18,201 ,,••,, A WARNING - Vvify d.iyn par ter. and RSdD NOTES ON THIS AAD i7YCLUDED hETSKREFERENCS PAGE 1W.7473 rr✓. 10-'08 BEFORE USB, *R• Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and Is for an individual building component. I■.YOF■3 Applicability of design poramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure B the responsibility of the building designer. For general guidance regarding MiTek` fabrication, quality control, storage. delivery, erection and bracing, consult ANSI/TPII Quality CrBeda, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Infarnratlon available from Truss Plate Institute, 781 N. Lee Street, Suite 312. Alexandria, VA 22314. Tampa, FL 33610.4115 Job Truss Truss Type Oty Ply 22137 - KLEIN, RON - KLEIN RE -ROOF T4055658 22137 -CJ5S JACK -OPEN TRUSS 8 1 Job Reference OD tional East Coast Truss, FORT PIERCE, FL. 34946 7.250 s Jan 28 2011 MiTek Industries, Inc. Mon Apr 18 14:46:02 2011 Page 1 _ ID:ZycEGXaGi5uaivl hsBRj37zPYdX-It8BmdxVGENwTcHbfLmOZXRORU2kzvYn?dBwgBzPTAJ -2-0-0 0-9-0 5-0-0 2-0-0 0-9-0 4-2-12 y Scale = 1:15.5 3 N 5x10 = b 2 N N N f i 1 4 6 2x4 I 5 Plate Offsets X 2:0-3-4 0-2-8 LOADING (psf) SPACING 2-0-0 CSI DEFL in -(loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.54 Vert(LL) -0.04 4-5 >999 240 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.36 Vert(TL) -0.05 4-5 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.02 4 n/a n/a BCDL 5.0 Code FBC2007/TPI2002 (Matrix) Weight: 26 lb FT=20% LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins, except end verticals. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2 X 4 SYP No.2 MiTek recommends that Stabilizers and required cross bracing be installed during OTHERS 2 X 10 SYP No.2 truss erection in accordance with Stabilizer Installation guide. REACTIONS (lb/size) , 3=79/Mechanical, 4=19/Mechanical, 7=248/D-8-0 (min. 0-1-8) Max Harz 7=219(LC 4) Max Uplift3=-168(LC 4), 7=-633(LC 4) Max Grav 3=95(LC 2), 4=218(LC 13), 7=300(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-05; 150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18f1; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 2) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) • This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2.0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Bearing at joint(s) 7 considers parallel to grain value using ANSVTPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing.plale capable of withstanding 168 lb uplift at joint 3 and 633 lb uplift atjoint 7. 8) This truss has been designed for a moving concentrated load of 200.01b live located at all mid panels and at all panel points along the Bottom Chord, 111 /1' nonconcurrent with any other live loads. `1111111 0 Q,v'' I V ` 1� I 1 , 9) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. �� • �F` �• LOAD CASE(S) Standard %```pP. ; J .'��C•E•N SF•• ��� i b N 68182 b _ e 1� T OF �•� , b O�.• b � � I .,it FL Cert. 6634 April 18,201 A WARMIdt3. Verify d-iyrz p-r ndmw and READ N07ES ONTHIS AAW INCLUDED 1drrff REFERENCB PAGR W1-7473 reu. 10-"08 BEFORE USB. *R� Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. ■��7Y�q■■■ Applicability of design paromenters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown MiTek" is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding o .4 ro r• . A fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Bullding Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610.4115 HrJob Truss Truss Type Qty Ply KLEIN, RON - KLEIN RE -ROOF �22137- T4056659 22137 -EJ7 Jack -Partial Truss 19 1 Jab Reference (option a East Coast Truss, FORT PIERCE, FL. 34946 7.250 s Jan 28 2011 MiTek Industries, Inc. Mon Apr 18 14:46:03 2011 Page 1 ID:ZycEGXaGi5uaivlhsBRj37zPYdX-D4iW zy71XVn5msoD3Hd61_EsuKFiMoxEHwTMdzPTAI -2-0-0 3-6-10 7-0-0 2-0-0 3-6-10 3-5-6 Scale = 1:16.8 3 1 � 2 1 5 4 4x4 = 7-0-0 7-D-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (too) I/deg L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.37 Vert(LL) -0.17 2-4 >453 240 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.59 Vert(TL) -0.23 2-4 >342 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a Na BCDL 5.0 Code FBC2007/TPI2002 (Matrix) Weight: 32 lb FT=20% LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or IG-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 3=129/Mechanical, 2=299/0-8-0 (min. 0-1-8), 4=31/Mechanical Max Harz 2=258(LC 4) Max Uplift 3=-290(LC 4), 2=-675(LC 4) Max Grav 3=157(LC 2). 2=360(LC 2). 4=230(LC 13) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-05; 150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. 11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 2) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 290 lb uplift at joint 3 and 675 Ito uplift at joint 2. 7) This truss has been designed for a moving concentrated load of 200.O1b live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. 8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. ``�111111111///�, LOAD CASES) Standard U 1 N V� ,`%OA^ • • 4�'' N 68182 :�•• T OF ��� • Q••• �U . i P N % .� S,c 1•p II11111111` FL Cert. 6634 April 18,201 ® WARNING - 7erijy dcsiya parameters and READ NOTES ON THIS AND INCLUDED M=REFERENCE PAGE 141I-7473 rea. 10-'08 BEFORE USE. Design varid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. �R F■� Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown 6 for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding MiTek Po.r +• • s fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610-4115 FM Job Truss Type Oty Ply 22137 -KLEIN, RON - KLEIN RE -ROOF T4055660 22137 [russ EJ7S JACK -PARTIAL TRUSS 4 1 Job Reference (op —tonal) East Coast Truss, FORT PIERCE, FL. 34946 7.250 s Jan 28 2011 MiTek Industries, Inc. Mon Apr 18 14:46:04 2011 Page 1 ID:ZycEGXaGi5uaivlhsBRj37zPYdX-hGGvBJzlordejwR nmoseyWMwlgXRp24TxgOv4zPTAH i -2-0-0 0.6.E 0-9-0 3-8-14 7-0-0 2-0-0 0-2-14 2-11-10 3-3-2 ` Scale = 1:19.2 3 5x10 = 2 1 4 I° d N •d d B 6 5 3x4 II 7-1-5 6-4-1 Plate Offsets X 2:0-3-4 0-2-8 LOADING (psf) SPACING 2-D-0 CSI DEFL in (loc) Udefi L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.54 Vert(LL) -0.16 4-5 >491 240 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.59 Vert(TL) -0.22 4-5 >372 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.05 4 Na Na BCDL 5.0 Code FBC2007/TP12002 (Matrix) Weight: 34 lb FT=20% LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puriins, except end verticals. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 6.0-0 oc bracing. WEBS 2 X 4 SYP No.2 MiTek recommends that Stabilizers and required cross bracing be installed during OTHERS 2 X 10 SYP No.2 truss erection in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 3=130/Mechanical, 4=31/Mechanical, 7=294/0-8-0 (min. 0.1-8) Max Horz 7=273(LC 4) Max Uplift 3=294(LC 4), 7=-696(LC 4) Max Grav 3=158(LC 2), 4=229(LC 13), 7=355(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-05; 150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat 11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 2) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Bearing at joint(s) 7 considers parallel to grain value using ANSIIrPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 294 lb uplift at joint 3 and 596 lb uplift atjoint 7. 8) This truss has been designed for a moving concentrated load of 200.OIb live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. "Semi design truss. I� 1 1 , I V ✓ 9) -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and of this 1 ` I� LOAD CASE(S) Standard ```AQ''v ` :� JO •�\Ci•E N S�•• �j i N 68182 :�•• T OF '•�: ' . o•'. i FL Cert. 6634 April 18,2011 ® 67ARMNG - V.Hfy d-iT, pmvmetera and READ N0713S ON THIS AND INCLUDED IGTEK REFERENCE PAGE 14U-7473 rev, I0-'08 BEFORE USE Design for only with MTek connectors. This design is based only upon parameters shown, and is for an individual building component. R q■■■■ valid use Applicability of design paramenters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction b the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding MiTek• fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality CrBerla, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610-4115 "M Job Truss Truss Type Oty Ply 22137 -KLEIN, RON - KLEIN RE -ROOF T4055662 22137 -HJ7A DIAGONAL HIP GIRDER 1 �f 2 Job eference o t'o a East Coast Truss, FORT PIERCE, FL. 34946 7.250 s Jan 28 2011 MiTek Industries, Inc. Mon Apr 18 14:46:06 2011 Page 1 ID:ZycEGXaGi5uaivl hsBRj37zPYdX-df0fc?_?JSuMyDbNuBrKjNcjy6F_vWrNwF97zyzPTAF -2-9-15 5-1-4 6-7-3 9-10-13 2-9-15 5-1-4 1-5-15 • 3-3-10 Scale = 1:23.0 3x4 I 5 6 6x8 4x10 = 10 4 �. 3 .; 3x4 = 2 1 11 13 8 6x10 = 12 9 7 3x10 II 6x10 = 3-7-3 2-6.6 -5-11 3-3-10 Plate Offsets X 2:0-5-1 0-3.0 LOADING (psf) SPACING 2-0.0 CSI DEFL in (too) Udell Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.50 Vert(LL) -0.01 8-9 >999 240 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.98 Vert(TL) 0.01 8-9 >999 180 BCLL 0.0 Rep Stress Incr NO WB 0.81 Horz(TL) 0.04 6 n/a We BCDL 5.0 Code FBC2007/TPI2002 (Matrix) Weight: 130 Ib FT = 20 LUMBER BRACING TOP CHORD 2 X 6 SYP SS TOP CHORD Structural wood sheathing directly applied or 5.11-11 oc purlins, except end verticals. BOT CHORD 2 X 6 SYP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2 X 4 SYP No.3 SLIDER Left 2 X 4 SYP No.22-10-5 REACTIONS (lb/size) 6=83/Mechanical, 8=-1537/Mechanical, 9=2363/0-11-5 (min. 0-1-11) Max Harz 9=247(LC 4) Max Uplift 6=-225(LC 4), 8=-1864(LC 2). 9=-6066(LC 4) Max Grav 6=102(LC 2). 8=3997(LC 4), 9=2855(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2.3=-8323/3871, 3-10=-8310/3952, 4-10=-8309/3952, 5-8=-536/241 BOT CHORD 2-11=-3856/8324, 11-12=-3856/8324, 9-12=-3856/8324, 9-13=-3856/8076, 8-13=-3856/8076 WEBS 4-8=-8371/4002, 4-9=-2586/5398 NOTES 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2 X 6 - 2 rows at D-9-0 oc, 2 X 4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2 X 6 - 2 rows at 0.9-0 oc. Webs connected as follows: 2 X 4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. _ 3) Wind: ASCE 7-05; 150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat 11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and i r ► r r right exposed; Lumber DOL=1.33 plate grip DOL=1.33 ♦♦��,, � ' ` / 1 V�4 4) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 5) This truss has been designed for a 10.0 bottom chord live load nonconcurrent with any other live loads. ♦%%%% 6.01 " psf 3-6-0 tall by 2-0-0 will fit between the bottom chord !✓•E s' c .• ��� 6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle wide :� , ••. �� ` and any other members. i 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 225 lb uplift at joint 6, 1864 lb uplift at joint 8 and 5066 lb uplift at joint 9. N 68182 -9) This truss has been designed for a moving concentrated load of 200.OIb live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. 10) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. to truss at the bearings. Building ,. 11) This truss has large uplift reaction(s) from gravity load rase(s). Proper connection is required secure against upward movement designer must provide for uplift reactions indicated. ', T O F .• 1JJ 12) Hanger(s) or other connection devices) shall be provided sufficient to support concentrated load(s) 186 lb down and 334 Ito up at -2-9-15, and 186 lb down and 0 • 334 lb up at-2-9-15 on top chord. The design/selection of such connection device(s) is the responsibility of others. I •• P ,r• • ,,�� LOAD CASE(S) Standard Lumber Increase=1.25, Plate Increase=1.25 V • • • • • • `' O • • C1> %% ,,,����rr' 1) Regular: V �' Concentrated Loads (lb) \\♦♦,` Vert:1=-305(F=-153, B=-153) Trapezoidal Loads (plf) Vert: 1=0(F=22, 8=22)-10-10=-99(F=-27, B=27), 10=0(F=22, 8=22)-to-5=-39(F=2, B=2), 5=-39(F=2, B=2)-t0-6=-41(F=1, B=1), 2=0(F=5. B=5)-to-12=-22(F=-6, B=-6), 12=0(F=5, B=5)-to-7=-9(F=0, B=0) FL Cert. 6634 April 18,201 LVARMNG - 7-ify dasiyn pm•ametms and R&W NOTES ONTBIS AND INCLUDED M =REFMZENCB PAGE t fI-7473 r--. 20-108 BEFORE USE. ��• Design valid for use only with MiTek connectors. This design is based any upon parameters shown, and is for an individual building component. Applicability of design poramenters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stabilityduring construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding MiTek WE— — --- fabrication. quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610-4115 Truss Type Ply 22137-KLEIN, RON- KLEIN RE -ROOF �Qty T4055663 �Truss:,F:ORT P'U's". DIAGONAL HIP GIRDER 4 1 FEast Job efere ce o Clonal st PIERCE, FL. 34946 7.250 s Jan 28 2011 MiTek Industries, Inc. Mon Apr 18 14:46:08 2011 Page 1 ID:ZycEGXaGiSuaivl hsBRj37zPYdX-a1 VP 1 gOGr4B4BXklOctopoh0av5oNZlgNZeE2rzPTAD -2-9-15 2-5-15 6-0-10 9-10-13 2-9-15 2-5-15 3-6-11 3-10-3 r Scale = 1:23.3 2x4 II 5 6 4x8 = v h 4 6x8 = r 3 13 2 1� 1 14 15 12 8 19 3x4 = g 7 6x6 18 3x4 16 17 10 3x4 II 11 i 2-5-15 6-0-10 i _ 9-10-13 9-11�14 2-5-15 3-6-11 3-1D-3 0--1 Plate Offsets X 3:0-5-4 0-2-8 LOADING (psi) SPACING 2-0.0 CSI DEFL in (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.69 Vert(LL) -0.03 9-10 >999 240 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.38 Vert(TL) -0.04 9-10 >999 180 BCLL 0.0 ' Rep Stress Incr NO WB 0.20 Horz(TL) -0.01 8 Na n/a BCOL 5.0 Code FBC2007/TPI2002 (Matrix) Weight: 68 lb FT=20% LUMBER BRACING TOP CHORD 2 X 6 SYP No:2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD 2 X 4 SYP No.2 *Except' BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. Except: 3-10: 2 X 4 SYP No.3 10-0-0 oc bracing: 10-12 WEBS' 2 X 4 SYP No.3 MiTek recommends that Stabilizers and required cross bracing be installed during Eck erection in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 6=214/Mechanical, 8=638/Mechanical, 2=366/0-11-5 (min. 0-1-8) Max Harz 2=295(LC 4) Max Uplift6=-255(LC 2), 8=-1105(LC 4), 2=-825(LC 4) Max Grav 6=369(LC 4), 8=757(LC 2), 2=439(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-659/281, 3-4=-577/342, 5-8=-482/804 BOT CHORD 2-14=-420/617, 14-15=-420/617, 12-15=-420/617, 9-19=-675I488, 8-19=-670/494 WEBS 9-12=-641/438, 4-12=-54/274, 4-9=-94/263, 4-8=-490/670 NOTES 1) Wind: ASCE 7.05; 150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. 11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3.6-0 tall by 2-D-0 wide will fit between the bottom chord and any other members. 5) Refer to for truss to truss connections. girder(s) truss to bearing capable of withstanding 255 lb uplift at joint 5, 1105 lb uplift at joint 8 and 825 lb uplift at joint 2. �1111111111j1 6) Provide mechanical connection (by others) of plate Chord, ,% 7) This truss has been designed for a moving concentrated load 200.OIb live located at all mid panels end at all panel points along the Bottom of live loads. • Q r, `� ,♦♦ nonconcurrent with any other 8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. ��, • C•E•N • ••• 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). '•• ♦0 N 68182 • •• LOAD CASE(S) Standard * 1Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-13=-44 / Loads Trapezoidal (plf)�f� 5=-107(F=-31, 8=-31)-to-6=-109(F=-32, B=-32), 2=-1(F=5, B=5)-to-12=-7(F=2, 8=2), ll=-3(F=4, 0 Y ', T O F Vert: 13=0(F=22, B=22)-to-5=-107(F=-31, B=-31), A •! /•'c./ B=4)-to-10=-7(F=2, B=2), 10=-7(F=2, B=2)-to-7=-25(F=-7, B=-7) IIIIIIIIIiII� FL Cert. 6634 April 18,2011 ® WARWNG - Verify design pm•ametere and READ NOTES ON IBIS AND INCLUDED 1ffl7FKREFERENCB PAGE M -7473 rea, I0-'08 BEFORE USB. Design for MiTek This design is based only upon parameters shown, and Is for an individual building component. �• valid use only with connectors. Applicability of design paromenters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown insure during is the the ■■■ MiTek' is for lateral support of individual web members only. Additional temporary bracing to stability construction responsibility of bracing the is the of the building designer. For regarding nK erector. Addi1lonal permanent of overall structure responsibility general guidance fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII quality Criteria, DSB-89 and BC51 Building Component eo,•re+r, e . 69D4 Parke East Blvd. Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610-4115 P1- r-9 Job toss Truss Type Oty Py 22137 - KLEIN, RON - KLEIN RE -ROOF T4055664 22137 O1 Common Truss 8 1 JoD Re ere ce 0 tIQnal East Coast Truss, FORT PIERCE, FL. 34946 7.250 s Jan 28 2011 MiTek Industries, Inc. Mon Apr 18 14:46:09 2011 Page 1 _ ID:ZycEGXaGi5uaivlhsBRj37zPYdX-2E3oE00ucNGxphJxaKO1LOEEHJOJ6zMpcDNnaHzPTAC -2-0-0 7-0-8 13-0-0 18-11-8 26-0-0 28-0.0 2-0-0 7-0-6 5-11-8 5-11-8 • 7-0-8 Scale: 1/4"=l' 5x6 = 4 3x4 3x4 a 3 5 2 6 7 d 12 11 13 10 9 14 8 15 3x8 = 3x8 = 3x4 = 1x4 II 1x4 II 3x8 = 7-0-8 13-0-0 18-11-8 26-0-0 7-0-8 5-11-8 5-11-8 7-0-8 LOADING (psl) SPACING 2-0-0 CSI DEFL in (loc) VdeH Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.50 Vert(LL) 0.33 9-11 >913 240 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.55 Vert(TL) -0.28 8-9 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.44 Horz(TL) -0.11 6 n/a Na BCDL 5.0 Code FBC2007/TPI2002 (Matrix) Weight: 138 lb FT=20% LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 5-1.9 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 3-9-7 oc bracing. WEBS 2 X 4 SYP No.3 MiTek recommends that Stabilizers and required cross bracing be installed during rection in accordance with Stabilizer Installation guide. truss erection. REACTIONS (lb/size) 2=787/0-8.0 (min. 0.1-8), 6=787/0-8.0 (min. 0.1-8) Max Harz 2=167(LC 4) Max Uplift 2=-1417(LC 6), 6=-1417(LC 7) Max Grav 2=937(LC 2). 6=937(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2228/2737, 3-4=-1615/1975, 4-5=-1615/1975, 5-6=-2228/2741 BOT CHORD 2-12=-2607/2097, 11-12=-2607/2097, 11-13=-2607/2097, 10-13=-2607/2097, 9-10=-2607/2097, 9-14=-2466/2097, 8-14=-2466/2097, 8-15=-2466/2097, 6-15=-2466/2097 WEBS 4-9=-456/429, 5-9=-654/973, 5-8=0/259, 3-9=-654/967, 3-11=01259 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. 11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 3) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrenl with any other live loads. 5) • This truss•has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1417 lb uplift at Joint 2 and 1417 Ib uplift at joint B. 7) This truss has been designed for a moving concentrated load of 200.01b live located at all mid panels and at all panel points along the Bottom Chord, ,�\ s 1 + N V nonconcurrent with any other live loads. 8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. PQ ........ . .. %� O EI, LOAD CASE(S) Standard elo N 68182 Ift _ T O F : �U✓ f • O'. 01 FL Cert. 6634 April 18,201 ® 67,,77 - Verify design parameters end READ N07M ON THIS AND INCLUDED W7EKREPERENCE PAGE MI.7473 rrv. 10-'08 BEFORE USE. • Design valid for use any with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. my q■ Applicability of design paromenters and proper Incorporation of component is responsibility of building designer- not truss designer. Bracing shown ' k for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardng MiTek , .— -- fabrication. quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality CrHerla, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610.4115 Job Truss Truss Type City Ply 22137 - KLEIN, RON - KLEIN RE -ROOF T4055665 22137 A02G Common Truss 1 1 job Reference o tlo a East Coast Truss, FORT PIERCE, FL. 34946 7.250 s Jan 28 2011 MiTek Industries, Inc. Mon Apr 18 14:46:11 2011 Page 1 _ ID:ZycEGXaGi5uaivlhsBRj37zPYdX-_cBYfi288?We2 TKhkRVQRJUf73datX64XsueAzPTAA -2-0-0 9-3-0 13-0-0 16-8-12 26-0-0 28-0-0 2-0-0 9-3-4 3-8-12 3-8-12 9-3A 2-0-0 • Scale: 1/4"=T 5x5 = 4 3x4 3x4 3 5 2 6 ' I, Id. 12 13 14 11 15 10 9 16 8 17 18 19 WO= _ 2x4 11 4x6 2x4 11 3x10 = 3x10 = i 9-3A 13-0.0 16-8-12 26-0-0 9-3-4 3-8-12 3-8-12 9-3-4 Plate Offsets X 2:0.4-8 0.1-8 6:0-4-8 0-1-8 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.89 Vert(LL) 0.40 9-11 >761 240 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.56 Vert(TQ 0.31 9-11 >966 180 BCLL 0.0 ' Rep Stress Incr NO WB 0.40 Horz(TQ -0.10 6 Na n/a BCDL 5.0 Code FBC2007/TPI2002 (Matrix) Weight: 155 lb FT = 20% LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 4-2-15 oc purlins. BOT CHORD 2 X 6 SYP No.2 BOT CHORD Rigid ceiling directly applied or 3-10-7 cc bracing. WEBS 2 X 4 SYP No.3 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 2=970/0-8-0 (min. 0-1-8), 6=970/0-8-0 (min. 0.1-8) Max Harz 2=-171(LC 5) Max Uplift 2=-1775(LC 6), 6=-1775(LC 7) Max Grav 2=1156(LC 2), 6=1156(LC 2) FORCES (Ib) -Max. Camp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3DO2/3983, 3-4=-2233/3025, 4-5=2233/3026, 5-6=-3002/3985 BOT CHORD 2-12=-3793/2845, 12-13=-3793/2845, 13-14=-3793/2845, 11-14=-3793/2845, 11-15=-3793/2845, 10.15=-3793/2845, 9-10=-3793/2845, 9-16=-3645/2845, 8-16=-3645/2845, 8-17=-3645/2845, 17-18=-3645/2845, 18-19=-3645/2845, 6-19=3645/2845 WEBS 3-11=-268/546, 5-8=-267/546, 4-9=-13361970. 3-9=-870/1324, 5-9=-870/1328 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7.05; 150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf, h=18ft; Cat 11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 3) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0.0 wide will fit between the bottom chord and any other members. 6. �111111 1 1111I /, 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1775 Its uplift atjoint 2 and 1775 lb uplift atjoint the Bottom Chord, `�� t IN 7) This truss has been designed for a moving concentrated load of 200.O1b live located at all mid panels and at all panel points along loads. .s .. • `,Of- nonconcurrent with any other live 8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. ,�L�Q' �• �� , \ G E N S♦♦ ••�. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 277 lb down and 358 Ib up at 9-3-4, and 277 Ito down and 358 �' lb up at 16-8-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. N 68182 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). �OAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 • Uniform Loads (plf) : '. T O F Vert: 1.4=-44, 4-7=-44, 2-6-10 •!44/ Concentrated Loads (lb) Vert: 11=183(F) 8=-183(F) ♦j P •� • J*5 N FL Cert. 6634 April 18,201 A VZARWN&- Verify design pou—t ere and READ NO TES ON THIS AND INCLUDED 07EKREFERENCE PAOB 1W-7473 rev. IO-'08 BBFORB USE. r.� a ami Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and Is for an individual building component. 1■■�v its Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the respomibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding MiTek" ow fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality CrBerla, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610-4115 Job Truss Truss Type Qly�221KLEIN N.RE-ROOFT4055666 22137 03 Hip Truss 1l East Coast Truss, FORT PIERCE, FL. 34946 7.250 s Jan 28 2011 Industries, Inc. Mon Apr 18 14:46:12 2011 Page 1 ID:ZycEGXaGi5uaivl hsBRj37zPYdX-Splws23mvleVg82 WFSykzesjoWLUJNUGIBcRBczPTA9 -2-0-0 6-0-8 11-0-0 15-0-0 9-1 1-8 26-0-0 28-0-0 • 2.p_0 6-0-8 4-11-8 4-0-0 4-11-8 6-0-8 2-0-0 Scale: 1/4"=1' 5x8 = 6x6 = 4 5 2x4 2x4 3 6 2 7 8 61 d d 3x6 = 12 11 10 13 9 14 3x6 = 3x6 = 3x8 = 3x4 = 11 0-0 15-0-0 26-0-0 r 11_0-0 4-0-0 11-0-0 Plate Offsets MY), 4:0-5-4 0-2-12 LOADING (psf) SPACING 2-D-0 CSI DEFL in (loc) Udell Vd PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.54 Vert(LL) -0.49 2-11 >615 240 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.78 Vert(TL) -0.81 2-11 >376 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.23 Horz(TL) -0.11 7 n/a n/a BCDL 5.0 Code FBC2007/rP12002 (Matrix) Weight: 141 lb FT=20% LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 5-1-13 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 3-7-13 oc bracing. WEBS 2 X 4 SYP No.3 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 2=787/0-8-0 (min. 0-1-8), 7=787/0-8-0 (min. 0-1-8) Max Harz 2=148(LC 4) Max Uplift 2=-1437(LC 4), 7=-1437(LC 5) Max Grav 2=937(LC 2), 7=937(LC 2) FORCES (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2201/2887, 3-4=-1812/2277, 4-5=1746/2286, 5-6=-1815/2280, 6-7=-2201/2892 BOT CHORD 2-12=-2756/2072, 11-12=-2756/2072, 10-11=-2068/1743, 10-13=-2068/1743, 9-13=-2068/1743, 9-14=-2614/2072, 7-14=-2614/2072 WEBS 3-11=-384/752, 4-11 =-1 54/295, 6-9=-381/755 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 150mph (3-second gust); TCDL=4.2psf; BCDL=3.0psf; h=18ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 3) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 pat bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. /j1j 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1437 lb uplift atjoint 2 and 1437 lb uplift at joint 7. ``111111111 V 8) This truss has been designed for a moving concentrated load of 200.0Ib live located at all mid panels and at all panel points along the Bottom Chord, ff,�-• �� nonconcurrent with any other live loads. "Semi heels" Member fixity was used in the analysis and design of this truss. ,`�%, % , G•E N S • • �j 40 9) -rigid pitchbreaks including end model ; �.' �'.,• s LOAD CASE(S) Standard N 68182 n 1 �•� T OF 11/11111111 FL Cert. 6634 April 18,201, ®WARMNO- Verify d.dW,pasnmetersandREAD N07VSCmmi36NIDINCLUDEDDB7EKREFERENCE PAGE BIII.7473rev.IO-'08BEFORE USS. Design valid for use only with M7ek connectors. This design is based only upon parameters shown, and is for an individual building component. ■■�� IYYF� Applicability of design paramenters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown MiTek' is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibiility of the bracing of the overall structure is the responsibility of the building designer. For general guidance regarding erector. Additional permanent fabrication, quality control, storage, delivery, erection and bracing. consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610-4115 Job cuss Truss Type Ory -KLEIN, RON -KLEIN RE•ROOFT4055667 771,31 22137 04 Hip Trussfe ce (optional) East Coast Truss, FORT PIERCE, FL. 34946 7.250 s Jan 28 2011 MiTek Industries, Inc. Mon Apr 18 14:46:13 2011 Page 1 _ ID:ZycEGXaGiSuaivl hsBRj37zPYdX-w?J I4O4OgcmMl Idjp9TzWs0sbwjS2pDPXrL?j2zPTA8 -2-0-0 9-0-0 17-0-0 26-0-0 28-0-0 - 2-0-0 11, 8-0-0 9-0-0 2-0-0 Scale: 1/4"=l' 6x8 = 7x8 = 3 4 !:22 5 ' 6 Id d 3x8 = 10 9 8 11 7 12 3x8 = 1x4 II 3x8 = 3x4 = 9-0-0 17-0-0 26-0-0 9-0.0 8-0-0 9-0-0 Plate Offsets X Y : 2:0-2-8 0-1-8 &0-5-40-4-0 5:o-2-9 0-1-8 LOADING (pso SPACING 2-0-0 CSI DEFL in (loc) VdeB Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.67 Vert(LL) 0.36 7-9 >842 240 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.67 Vert(TL) -0.51 2-9 >600 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.26 Horz(TL) -0.11 5 Na n/a BCDL 5.0 Code FBC20071TP12002 (Matrix) Weight: 128 lb FT=20% LUMBER BRACING TOP CHORD 2 X 6 SYP N6.2 TOP CHORD Structural wood sheathing directly applied or 5-0-7 oc purlins. BOT CHORD 2 X 4 SYP No,2 BOT CHORD Rigid ceiling directly applied or 3-9-8 oc bracing. WEBS 2 X 4 SYP No.3 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 2=787/0-8-0 (min. 0-1-8), 5=787/0-8-0 (min. 0-1-8) Max Harz 2=128(LC 4) Max Uplift 2=-1468(LC 4). 5=-1468(LC 5) Max Grav 2=937(LC 2). 5=937(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2.3=-2116/2737, 3-4=-1993/2754, 4.5=-2121/2742 BOT CHORD 2-10=-2569/1983, 9-10=-2569/1983, 8-9=-2566/1988, 8-11=2566/1988, 7-11=-2566/1988, 7.12=-2446/1988, 5-12=-2446/1988 WEBS 3-9=0/285, 4.7=-11/258 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18R; CaL II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 3) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 1468 Its 2 1468 Ito at 5. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding uplift aljoint and uplift joint t 5, N V the Bottom Chord, 8) This truss has been designed for a moving concentrated load of 200.01b live located at all mid panels and at all panel points along ,%,AQ. with any other live loads.•'''E' nonconcurrent 9) "Semi -rigid pitchbreeks including heels" Member end fixity model was used in the analysis and design of this truss. ,• G S L.'. �\ : i LOAD CASE(S) Standard N 68182 y q /yam T O F • �(/ ��.• v FL Cert. 6634 April 18,201 AOy WARWM- Verify design pcun et.w and REW N07ES ON 77II5 AND INCLUDED 11 =REFERENCB PAGE AW-7473 rca. 20•'08 BEFORE USE. Design valid for use only with MTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design paramenters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown to insure during is the the MiTek• is for lateral support of Individual web members only. Additional temporary bracing stability construction respomibillity of erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria. VA 22314. Tampa, FL 33610-4115 Job Truss Truss Type PN 22137 - KLEIN, RON - KLEIN RE-ROOFT4055668 22137 AOSG Hip Truss ��Jty 1 Job Reference (optional East Coast Truss, FORT PIERCE, FL. 34946 7.250 s Jan 28 2011 MiTek Industries, Inc. Mon Apr 18 14:46:15 2011 Page 1 _ ID:ZycEGXaGiSuaivl hsBRj37zPYdX-tNQ3V45fCD04Xcn5waVRbHT8fkK1 Wf)i_Bg6nxzPTA6 -2-0-0 7-0-0 13-0.0 19-0.0 26-0-0 28-0.0 2-0-0 7-0-0 6-0-0 6-0-0 7-0-0 Scale: 1/4"=l' 6x12 MT18H = 3x8 I I Bx12 MT18H = 3 4 5 2 6 lb cs 4x14 = 12 11 13 10 9 14 8 15 4x14 = 1x4 I I 1x4 II 3x10 MT1 OH = 4x8 = i 7-0-0 13-0-0 19-0-0 _ 26-0-0 7-0-0 6-0-0 6-0-0 7-0-0 Plate Offsets x 2:0-D-o D-D-a 3:0.6-0 0.&12 5:0.6-0 0.3-12 6:Ed a 0-0-4 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Vdefl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.95 Vert(LL) 1.14 9 >266 240 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.98 Vert(TQ 0.91 9 >332 180 MT18H 244/190 BCLL 0.0 ' Rep Stress Incr NO WB 0.52 Horz(TL) -0.28 6 Na n/a BCDL 5.0 Code FBC2007/TPI2002 (Matrix) Weight: 134 lb FT = 20 LUMBER BRACING TOP CHORD 2 X 6 SYP SS TOP CHORD Structural wood sheathing directly applied or 3-0-15 oc purlins. BOT CHORD 2 X 4 SYP SS 'Except- BOT CHORD Rigid ceiling directly applied. 6-10: 2 X 4 SYP No.1 WEBS 1 Row at midpt 3-9, 5-9 WEBS 2 X 4 SYP No.3 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 2=1483/0.8-0 (min. 0.2-1), 6=1483/0.8-0 (min. 0.2-1) Max Horz 2=109(LC 4) Max Uplift 2=2790(LC 4), 6=-2789(LC 5) Max Grav 2=1762(LC 2), 6=1762(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-5265/7751, 3-4=-6442/9672, 4-5=6442/9872, 5.6=-5262/7749 BOT CHORD 2-12=-7395/5020, 11-12=-7395/5020, 11-13=-7439/5058, 10.13=-7439/5058, 9-10=-7439/5058, 9-14=-7328/5055, 8-14=-7328/5055, ' 8-15=-7284/5016, 6-15=-7284/5016 WEBS 3-11=-573/635, 3-9=-2357/1580, 4-9=-741/1416, 5-9=-2365/1583,5-8=-573/635 ' NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 150mph (3-second gust); TCDL=4.2psf, BCDL=3.Opsf; h=18ft; Cat II; Exp C; enclosed; MVJFRS (low-rise) gable end zone; cantilever left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 3) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 4) Provide adequate drainage to prevent water ponding. indicated. 5) All plates are MT20 plates unless otherwise 6) This truss has been designed for a 10.0 pat bottom chord live load nonconcurrent with any other live loads. ,�� U IN 7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord f�Q • •N f` • and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 2790lb uplift atjoint 2 and 2789 Ito uplift at joint 6. ,,``�O C• , \ E S /i ••• �' •••• 9) This truss has been designed for a moving concentrated load of 200.o1b live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. 10) Girder hip end with 7-0-0 end setback.•• 68182 carries 11) "Semi -rigid pitchbreaks including heels" Member end fority, model was used in the analysis and design of this truss. 12) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 411 lb down and 644 lb up at 19.0-0, and 411 lb down and 644 lb up at 7-0-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 13) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). O FLOAD 4Nb CASES) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf)Vert: 1-3=-44, 3-5=92(F=-48), 5-7=-44, 2-11=-10, 8-11=21(F=-11), 6-8=-10ConcentrateVertd Lads(lb)) 8=-347(F) ill FL Cert. 6634 April 18,201 ® WdRMNO- Verify d-ign paramet— and REdD NO7ES ON INIS AND INCLUDED WTEKREPERENCE PAGE MI.7473 rvr. 10-VIE BEFORE USE, Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design paromeniers and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown Is for lateral support of individual web members only. Additional temporary bracing to insure stabilityduring construction is the responsibility, of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. or general guidance regarding MiTek' o— e• ro K fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610.4115 Job mss Truss Type Oly Ply 22137 -KLEIN, RON •KLEIN RE -ROOF T4055669 22137 06 Monopitch Truss 1 1 Job Reference o tional East Coast Truss, FORT PIERCE, FL. 34946 7.250 s Jan 28 9011 MiTek Industries, Inc. Mon Apr 18 14:46:15 2011 Page 1 _ ID:ZycEGXaGi5uaivl hsBRj37zPYdX-tNQ3V45fCD04Xcn5waVRbHT9KkRAWnmi_8g6nxzPTA6 9-2-8 11-2-8 _ 9-2-8 2-0-0 Scale = 1:20.3 4x4 II • 1 2 3 Id 4 3x8 = 3x4 II 9-2-8 9-2-8 Plate Offsets X 2:0-2-8 0-1-8 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Vd PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.85 Vert(LL) -0.32 2-4 >330 240 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.52 Vert(TL) -0.45 2-4 >232 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 2 We n/a BCDL 5.0 Code FBC2007/rP12002 (Matrix) Weight: 44 lb FT = 20% LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 1G.0-0 oc bracing. WEBS 2 X 4 SYP No.3 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 4=222/Mechanical, 2=352/0-8-0 (min. D-1-8) Max Harz 4=315(1_C 5) Max Uplift,$=398(1_C 5), 2=-752(LC 5) Max Grav 4=300(LC 12), 2=422(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-4=-212/411 NOTES 1) Wind: ASCE 7-05; 150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf, h=18ft; Cat 11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 3) This truss has been designed for a 10.0 lost bottom chord live load nonconcunent with any other live loads. 4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0.0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 398 Ito uplift at joint 4 and 752 Ito uplift at joint 2. 7) This truss has been designed for a moving concentrated load of 200.01b live located at all mid panels and at all panel points along the Bottom Chord, live loads. \11 nonconcurrent with any other 8) "Semi -rigid pilchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. \\\ 1 N LOAD CASE(S) Standard , S�•• �j I� .T-`�\C•E•N is i ♦ N 68182 ` T O F �U O�. i J FL Cert. 6634 April 18,201 ®WARNING - ➢estijy design pm tw and READ N0713S ON 7WIS AND INCLVDED M17E1CREPERENCE PAGE MII.7473 r-ro. I0- 08 BEFORE USE. • Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. � Applicability of design paramenters and proper incorporation of component Is responsibility of building designer- not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to Insure stabilityduring construction is the responsibillity, of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardng MiTek" eo •+o e . . fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safely Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610-4115 Job ss Type Q1 Ply 22137 - KLEIN, RON - KLEIN RE -ROOF T4055670 22137 r.7ss onopitch Truss r-M 1 1 Job eterence o tiona East Coast Truss, FORT PIERCE, FL. 34946 7.250 s Jan 28 2011 MiTek Intlustries, Inc. Mon Apr 18 14:46:16 2011 Page 1 ID:ZycEGXaGiSuaivl hsBRj37zPYdX-La_RiP6HzX8x9mMIUlOg7UOKF8nP FEOrpoafKNzPTA5 _0 9-2-8 2_p_p 9-2-8 Scale = 1:20.3 4x4 I I 3 2 LA 5 4 3x8 = 3x4 II 9-2-8 9-2-8 Plate Offsets X 2:0-2-8 0-1-8 LOADING (pst) SPACING 2-0-0 CSI DEFL in (too) Vdeft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.84 Vert(LL) -0.32 2-4 >330 240 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.52 Ven(TL) -0.45 2-4 >232 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 4 n/a Na BCDL 5.0 Code FBC2007/TPI2002 (Matrix) Weight: 44lb FT=20% LUMBER BRACING TOP CHORD 2 X 5 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2 X 4 SYP No.3 MiTek recommends that Stabilizers and required cross bracing be installed during rection in accordance with Stabilizer Installation guide. truss erection. REACTIONS (lb/size) 4=222/Mechanical, 2=352/0-8-0 (min. 0-1-8) Max Harz 2=315(LC 4) Max Uplift4=398(1_C 4). 2=-752(LC 4) Max Grav 4=300(LC 13), 2=422(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 3-4=-212/411 NOTES 1) Wind: ASCE 7-05; 150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. II; Exit C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed: Lumber DOL=1.33 plate grip DOL=1.33 2) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 398 lb uplift at joint 4 and 752 lb uplift at joint 2. 7) This truss has been designed for a moving concentrated load of 200.011c live located at all mid panels and at all panel points along the Bottom Chord, live loads. nonconcurrent with any other 8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. ``�1��) � 60I N VF LOADCASE(S) Standard `�� Or-•• G•E•NS • �� N 68182 1k , 1k �. T O F LJJ O�.• : FL Cert. 6634 April 18,201 WARNING. Verify design Parameters and READ M07ES ON THIS AND 1NCLVDED M77EKPETEREMCB PAGE M I-7473 rea. Z0-'08 BEFORE USE. ' Design valid for use only with M1ek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design paramenters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown Is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibifty of the building designer. For general guidance regarding MiTek' —..—.--- fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Ctfteria, DSO.89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute. 781 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610-4115 Job Truss Truss Type Qly Ply 22137 - KLEIN, RON - KLEIN RE -ROOF T4055671 22137 B01 Common Truss 11 1 Job efe ce o t onal East Coast Truss, FORT PIERCE, FL. 34946 7.260 s Jan 28 2011 MiTek Industries, Inc. Mon Apr 18 14:46:17 2011 Page 1 ID:ZycEGXaGiSuaivl hsBRj37zPYdX-pmYpwl7vkrGomvwU2?XvgiZbDX6h_gn?SSJCspzPTA4 -2-0-0 9-0-0 18-0-0 20-0-0 - 2-0-0 9-0-0 9-0-0 2-0-0 Scale = 1:34.9 5x8 = 3 2 4 5 d 7 6 8 4x4 = 5x6 = 4x4 = i 9-0-0 18-0-0 9-0-0 9-0-0 Plate Offsets X Y : 2:0-4-0 0-0-2 4:0-4-0 0.0-2 6:0-30 0-3-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (too) I/de8 Vd PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.50 Vert(LL) -0.31 2-6 1877 240 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.58 Vert(TL) -0.42 2-6 >499 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.10 Horz(TL) -0.03 4 n/a Na BCDL 5.0 Code FBC2007/rP12002 (Matrix) Weight: 83 lb FT=20% LUMBER BRACING TOP CHORD 2 X 6 SYP N6.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 5-9-1 oc bracing. WEBS 2 X 4 SYP No.3 MiTek recommends that Stabilizers and required cross bracing be installed during rection in accordance with Stabilizer Installation guide. truss erection. REACTIONS (lb/size) 2=571/0-8-0 (min. 0-1-8), 4=571/0-8-0 (min. 0-1-8) Max Harz 2=128(LC 5) Max Uplift 2=-1082(LC 6), 4=-1082(LC 7) Max Grav 2=681(LC 2), 4=681(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=1178/1314, 3-4=-1178/1313 BOT CHORD 2-7=-1150/1079, B-7=-1150/1079, 6-8=-1150/1079, 4-8=-1150/1079 WEBS 3-6=0/299 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf, h=18ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 3) This truss has been designed for basic load combinations, which include rases with reductions for multiple concurrent live loads. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0.0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1082 lb uplift atjoint 2 and 1082 lb uplift aljoinl4. 7) This truss has been designed for a moving concentrated load of 200.OIb live located at all mid panels and at all panel points along the Bottom Chord, `�\ �r 1 V I N 1 Vz� nonconcurrent with any other live loads. B) "Semi -rigid pilchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. `f� O � r �I •�C•E•Ns •. %�• ,•••� �••• LOAD CASE(S) Standard N cn 68182 T O�• �. O'. 1 FL Cert. 6634 April 18,201 ® WARNINO • Verify dr ign paramaima and READ N0773S ON 771IS AND INCLUDED X771_KREFERENCE PAOB MD•7473 r+eo. 70-'08 BEFORE USE. Design valid for use only with M1ek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design paramenters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibiility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding MiTek w.•,n P orcn.a ' fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312. Alexandria, VA 22314. Tampa, FL 33610-4115 a Job Truss Type City Ply 22137 - KLEIN, RON - KLEIN RE -ROOF T4055672 22137 2 pss Common TNss 1 1 Jab Reference o tional East Coast Truss, FORT PIERCE, FL. 34946 7.250 s Jan 28 2011 MiTek Industries, Inc. Mon Apr 18 14:46:18 2011 Page 1 - I D:ZycEGXaGiSuaivl hsBRj37zPYdX-Hy6B757XV8OfO3Vgbj38Cv5mUxNAjwg8h63mOGzPTA3 -2-0-0 4-8-0 9-0-0 18-0-0 20-0-0 2-0-0 4-8-0 4-4-0 9-0-0 2-0-0 Scale = 1:34.9 TRUSS NOT SYMMETRIC DO NOT ERECT THE TRUSS BACKWARDS 7x8 = 3 4 2 5 3x6 = 8 10 6 11 7 9 4x4 = 4x8 i 5x5 = 018-0-0 9-0-0 Plate Offsets X 2:0-2-8 0-0-2 3:0-4-0 0-2-12 4:0-4-0 0-D-2 6:0-2-8 0-3-4 LOADING (psf) SPACING 2-0.0 CSI DEFL in (too) I/deg Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.47 Vert(LL) -0.27 4-6 >585 240 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.89 Vert(TL) -0.40 4-6 >405 180 BCLL 0.0 ' Rep Stress Incr YES WE 0.95 Horz(TL) 0.01 4 Na n/a BCDL 5.0 Code FBC2007frP12002 (Matrix) Weight: 91 In FT=20% LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-10.4 oc puriins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 5-3-15 oc bracing. WEBS 2 X 4 SYP No.3 recommends that Stabilizers F2truss and required cross bracing be installed during erection in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 4=399/0-8.0 (min. 0-1-8), 7=74610-8-0 (min. 0-1-8) Max Horz 7=128(LC 5) Max Uplift4=-872(LC 5), 7=-1680(LC 6) Max Grav 4=503(LC 14). 7=889(LC 2) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2997/1358, 3-4=-469/494 BOT CHORD 2-8=-1255/3077, 7-8=-1255/3077, 7-9=279/401, 9.10=279/401, 6-10=-2791401, 6-11=-279/401, 4-11=-279/401 WEBS 3-6=0/270, 3-7=174313152 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat 11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left exposed ; Lumber D(I plate grip DOL=1.33 3) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 872 lb uplift at joint 4 and 1680 lb uplift at joint 7. ``1111111 fill.. I. 7) This truss has been designed for a moving concentrated load of 200.Olb live located at all mid panels and at all panel points along the Bottom Chord, Qv 1 N 1 V F! �// nonconcurrent with any other live loads. 8) "Semi -rigid pilchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. ,`,�� f� , �� O r • •E� LOAD CASE(S) Standard N 68182 -10 T k O�. o � C? FL Cert. 6634 April 18,201 ® WARMNG - Varify d+ ign parameims and READ N07ES ON 7EIS AND INCLUDED hD7EKREFERENCE PAGE 1,11I-7473 rea. 20-'08 BEFORE USE. Design valid for use only with MiTek connectors. This design is based only upon upon parameters,shown, and Is for an individual building component. �� Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stabilityduring construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibifty of the building designer. For general guidance regarding MiTek fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute. 781 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610-4115 _L Job Truss Type Oty Ply 22137 - KLEIN. RON - KLEIN RE -ROOF T4055673 22137 [.r.u,,.s Hip Truss 1 1 Job Reference (optional) East Coast Truss, FORT PIERCE, FL. 34946 7.250 s Jan 28 2011 MiTek Industries, Inc. Mon Apr 18 14:46:19 2011 Page 1 _ ID:ZycEGXaGi5uaivl hsBRj37zPYdX-19gZLR89GSVWVOD4s9QaN17euILhxSTOHvmoJxizPTA2 -2-0-0 7-0-0 11-0-0 18-0-0 20-0-0 7-0-0 2-0-0 Scale = 1:35.4 500 MT18H = 5x10 MT18H = 3 10 4 5 2 d 4x14 = 11 9 8 12 7 13 404 = 5xl0 MT18H WB = 7x6 3x8 I i 7-0-0 i 11-0-D 18-0-0 i 7-0-0 4-0-0 7-0-0 Plate Offsets X 2:G.0-0 0-0-0 3:0-s4 D-3-o 4:0-54 G-3-0 5:Ed a 0-0-4 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.66 Vert(LL) 0.56 7-9 >373 240 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.98 Vert(TL) -0.56 7-9 >371 180 MT18H 244/190 BCLL 0.0 ' Rep Stress Incr NO WB 0.56 Horz(TL) -0.17 5 n/a n/a BCDL 5.0 Code FBC2007frP12002 (Matrix) Weight: 92 lb FT = 20% LUMBER BRACING TOP CHORD 2 X 6 SYP SS TOP CHORD Structural wood sheathing directly applied or 3.1-14 oc puriins. BOT CHORD 2 X 4 SYP SS BOT CHORD Rigid ceiling directly applied or 2-4-4 oc bracing. WEBS 2X 4 SYP No.3 MiTek recommends that Stabilizers and required cross bracing be installed during OTHERS 2 X 4 SYP No.3 truss erection in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 5=1424/0-8-0 (min. 0-2-6), 2=1424/0-8-0 (min. 0-2-6) Max Harz 2=109(LC 4) Max Uplift 5=2614(LC 5), 2=-2614(LC 4) Max Grav 5=2010(LC 21), 2=2010(LC 18) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-6632f7033, 3.10=-6525/6963, 4-10=6525/6963, 4-5=-6657f7057 BOT CHORD 2-11=-6700/6369, 9-11=-5700/6369, 8-9=-6791/6506, 8-12=6791/6506, 7-12=-6791/6506, 7-13=-6629/6395, 5-13=-6629/6395 WEBS 3-9=-1179/1748, 4-7=-1222/1674 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. 11; Exp C; enclosed; MWFRS (low-rise) gable end zone; Lumber DOL=1.33 plate grip DOL=1.33 3) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 1 I l I l / 1j ss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0.0 wide will fit between the bottom chord `1111 7) Thistruss^' 1 ^ 1 1 ,� I V and \\`�\ �� •V 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 2614 lb uplift at joint 5 and 2614 lb uplift atjoint 2. ♦\\ oP , and at all along the Bottom Chord, ♦ • load 20O.Olb live located ' • G•E�N S' •' /i 9) This truss has been designed for a moving concentrated of at all mid panels panel points , �• �' •'. nonconcurrent with any other live loads. ♦♦ 10) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. N 68182 11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 103 lb down and 251 lb up at 7-0-0, and 103 lb down and 251 •� lb up at 9-0-0, and 103 lb down and 251 lb up at 11-0-0 on top chord, and 14191b down and 1228 Ito up at 7-0-0, and 170 Ito down at 9-0.0, and 1419 lb down �' : and 1228 lb up at 10.11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. s ' 12) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). l LOAD CASE(S) Standard i l' •. T O F 11+,) Regular: Lumber Increase=1.25, Plate Increase=1.25 O • �(/ 10 UnifoniTLoads (plf) •, Q' •• �♦ to Vert: 1-3=-44, 3-4=-44, 4-6=-44, 2-5=-10 - I� , • /�� ♦♦ �// SS • • •' •n' Concentrated Loads (Ib) • �v\\\ A 1� ,\\ Vert: 3=-85(B) 4=-85(B) 9=-716(B) 7=-716(B) 10= 85(B) 12=-21(B) /// � /lllllllll�` FL Cert. 6634 April 18,201 A WAPWNG-Verify design Parrimat.. and READ N07ES ON THIS AND INCLUDED MITEKREFERENCE PAGE M I-7473 r•ea. 10-'08 BEFORE USE. *R Design valid for use only with M1ek connectors. This design is based only upon parameters shown, and is for an Individual building component. ■.�YF�F■� Applicability of design paromenters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding MiTek' .ow• o,o P�a.o•.. fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSt Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610-4115 Job Truss Qly ply 22137 - KLEIN, RON - KLEIN RE-ROOFT4055674 22137 804G FrussType 1 1 Job Reference (optional) East Coast Truss, FORT PIERCE, FL. 34946 7.250 s Jan 2B 2011 MITek Industries, Inc. Mon Apr 18 14:46:20 2011 Page 1 - I D:ZycEGXaGi5uaivl hsBRj37zPYdX-DLEyYn9oOmeNdNf3j75cIKB4Tl11 BSRRBQYtTszPTAl -2-0-0 4-8-0 7-0.0 11-0-0 18-0-0 20-0-0 - 2-0-0 4.8-0 2-4-0 4-0-0 7-0.0 2-0-0 TRUSS NOT SYMMETRIC Scale = 1:35.4 DO NOT ERECT THE TRUSS BACKWARDS 8x14 MT18H = 5xl0 MT18H = 4 5 2x4 II 3 6 2 7 � d d 3x10 = 12 11 13 10 14 9 8 15 3x12 = 8x14 MT18H = 5x8 I I 5x6 WB = 3x4 = 4-4-0 014- 21-0 4-0-0 7-0-0 Plate Offsets X Y : 2:0-4-8 0-1-8 4:0-6-0 0-3-8 5:0-5-4 0-2-12 6:Ed a 0-0-2 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/de8 Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.63 Vert(LL) 0.29 8-10 -535 240 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.99 Vert(TL) -0.24 6-8 >642 180 MT18H 244/190 BCLL 0.0 ' Rep Stress Incr NO WE 0.80 Horz(TL) -0.12 6 Na n/a BCDL 5.0 Code FBC2007rrP12002 (Matrix) Weight: 99 lb FT=20% LUMBER BRACING TOP CHORD 2 X 6 SYP SS TOP CHORD Structural wood sheathing directly applied or 3-4-15 oc puriins. BOT CHORD 2 X 4 SYP No.1 'Except' BOT CHORD Rigid ceiling directly applied or 2-2-12 oc bracing. 5-9: 2 X 4 SYP No.2 MiTek recommends that Stabilizers and required cross bracing be installed during WEBS 2 X 4 SYP No.2 *Except* truss erection in accordance with Stabilizer Installation guide. 4-8: 2 X 4 SYP No.3, 3-11: 2 X 6 SYP No.2, 4-11: 2 X 6 SYP SS OTHERS 2 X 4 SYP No.3 REACTIONS (lb/size) 6=1214/0-8-0 (min. 0-1-12), 11=4571/0-8-0 (min. 0-6-6) Max Harz 11=109(LC 4) Max Uplift6=2359(LC 5), 11=8453(LC 4) Max Grav 6=1502(LC 14), 11=5423(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-4427/2402, 3-4=-4250/2347, 4-5=-4146/6084, 5-6=-430116162 BOT CHORD 2-12=-2304/4420, 11-12=-2304/4420, 11-13=-5878/4222, 10-13=-5078/4222, 10-14=-6371/4561, 9-14=-6371/4561, 8-9=-6371/4561, 8-15=-5755/4090, 6-15=5755/4090 WEBS 4-10=-6329/4357,4-8=-490/632, 5-8=-9001732,3-11=-349/674,4-11=-7914/11980 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat 11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 3) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 4) Provide adequate drainage to prevent water ponding. ^ r V 1' N 1 ��� ,' ``\\\ 5) All plates are MT20 plates unless otherwise indicated. �}V 6) This truss has been designed for a 10.0 bottom chord live load nonconcurrenl with any other live loads. . •' ' • • �j psf ,� OP• 7)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3.6-0 tall by 2-0-0 wide will fit between the bottom chord ♦ , • G E N S •' • �� • ♦ •• �' and any other members. i 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 2359 lb uplift at joint 6 and 8453 lb uplift atjoint 11. N 68182 1y 9) This truss has been designed for a moving concentrated load of 200.0Ib live located at all mid panels and at all panel points along the Bottom Chord, •; * y Tnonconcurrent with any other live loads. a 10) Girder carries hip end with 7-D-0 end setback. 11) "Semi -rigid pilchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 12) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 102 lb down and 149 lb up at 7.0-0, and 305 lb down and 446 lb up at -2-D-0 on top chord, and 411 lb down and 644 lb up at 11-0-0, and 4408lb down and 6487 lb up at 7-0-0 on bottom chord. The design/selection of such .• T O F � O.•• connection device(s) is the responsibility of others. mac/ 13) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). •'� _ 1.�P'•N % LOAD ) Standard �, 1) R gula : Lumber Incre se=1.25, Plate Increase=1.25 N AL E�.�` Uniform Loads (plf) , 111111111\\\ Vert: 1-4=-44, 4-5=-92(F=-48), 5.7=•44, 2-10=-10, 8-10=-21(F=-11), 6-8=-10 - Concentrated Loads (lb) Vert: 1=-258(F) 4=-86(F) 10=-3719(F) 8=-347(F) FL Cert. 6634 April 18,201 ® L7ARNT1,10- 9erify rTc;ig+c pa+nautm•s 1 READ N07ES ONYWISBN0 rNCLUDED MT112XREFERE'NCE PAGE RTI-7473 rw. 10•'09 BEFORE USE. Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and Is for an individual building component. Applicability of design paramenters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stabiityduring construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding MiTek' fabrication. quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Informalion available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610-4115 Job cuss Truss Type -KLEIN, RON -KLEIN RE-ROOFT4055676 22137 CO1 Half Hip TrussJob �QtyyRY221137 (optional) East Coast Truss, FORT PIERCE, FL. 34946 7,250 s Jan 28 2011 MITek Industries, Inc. Mon Apr 18 14:46:21 2011 Page 1 - I D:ZycEGXaGi5uaivl hsBRj37zPYdX-hXoK17AQn3mEFXEFHrcrgYjJD9WIwOXaN4HQ?bzPTAO -2-0-0 64-8 11-8-0 17-4-0 - 2-0-0 6-4-8 5-3.8 5-8-0 Scale: 3/8"=1' 5x8 = 2x4 II 4 5 3x4 3 2 10 9 11 8 7 12 3x4 = 1x4 II 3x4 = 3x4 = 6-4-8 i 11-8-0 6 3x4 = 174-0 r 6-4-8 5-3-8 5-8-0 Plate Offsets X 4:0-6-4 0-2-12 LOADING (psf) SPACING 2-0-0 CSI DEFL In (too) Udell Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.37 Vert(LL) 0.14 7-9 >999 240 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.45 Vert(TL) -0.16 2-9 >999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.49 Horz(TL) -0.04 6 n/a Na BCDL 5.0 Code FBC2007/TPI2002 (Matrix) Weight: 99 lb FT=20% LUMBER BRACING TOP CHORD 2 X 5 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0.0 oc purlins, except end verticals. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 4-7-3 oc bracing. WEBS 2 X 4 SYP No.3 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 6=448/0-8-0 (min. 0-1-8), 2=565/0-8-0 (min. 0-1-8) Max Harz 2=386(LC 4) Max Uplift6=794(LC 4), 2=-1116(LC 4) Max Grav 6=531(LC 2). 2=674(LC 2) FORCES (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1310/1673, 3-4=-727/976, 5-6=-140/260 BOT CHORD 2-10=-1828/1215, 9-10=-1828/1215, 9-11=-1828/1215, 8-1 1=-1828/1215,7-8=-1828/1215, 7-12=-1025/683, 6-12=1025/683 WEBS 3-9=0/254, 3-7=569/879, 4-7=-234/316, 4-6=-760/1145 NOTES 1) Wind: ASCE 7-05; 150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat 11; Fxp C; enclosed; MWFRS (low-rise) gable end zone; Lumber DOL=1.33 plate grip DOL=1.33 2) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2.0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 794 lb uplift at joint 6 and 1116 lb uplift at joint 2. Bottom Chord, 7) This truss has been designed for a moving concentrated load of 200.0Ib live located at all mid panels and at all panel points along the ns 1, N ♦ nonconcurrent with an other live loads. 8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. ♦%% ♦% O r-. • �I \GEMS• ••�.�� ••� � LOAD CASE(S) Standardlo : N 68182 ;� . OF •� O�. �#A FL Cert. 6634 April 18,2011 ® WARNING - Vicify dagiyn parr at ro and READ M07ES ON TTIIS AND INCLUDED MTEKREFERENCB PAGE MA-7473 >vsu. 10-'08 BEFORE USS. � Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. �� Applicability of design parameniers and proper incorporation of component is responsibility, of building designer- not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. Tor general guidance regarding MiTek' fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality CfBerla, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312. Alexandria, VA 22314. Tampa, FL 33610.4115 Job Truss Truss Type Ply 22137 - KLEIN, RON - KLEIN RE -ROOF T4055676 22137 CO2 Half Hip Truss JQty 1 1 Job Retere ce o do al East Coast Truss, FORT PIERCE, FL. 34946 7.250 s Jan 28 2011 MTek Industries, Inc. Mon Apr 18 14:46:22 2011 Page 1 _ I D:ZycEGXaGiSuaivl hsBRj37zPYdX-9kLizTB2YNv4lhpRgY74NIGQjYpDfsikbk1 zX1 zPTA? 17-4-0 Scale: 3/8"=T 5x10 = 3x4 II 3 4 2 8 75 9 3x8 = 5x5 = 5 4x4 = -8_p 17-4-0 9-8-0 7-8-0 Plate Offsets X 2:D-2-8 0-1-8 3:0-5-4 0.2-12 6:0-2-8 0-D-4 LOADING (psf) SPACING 2-O-0 CSI DEFL in (loc) VdeB L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.58 Vert(LL) -0.38 2-7 >527 240 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.62 Vert(TL) -0.55 2-7 >367 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.44 Horz(TL) -0.04 5 n/a n/a BCDL 5.0 Code FBC2007/TPI2002 (Matrix) Weight: 891b FT = 20% LUMBER BRACING - TOP CHORD 2 X 6 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 5-1-0 oc bracing. WEBS 2 X 4 SYP No.3 WEBS 1 Row at micipt 3-5 MiTek recommends that Stabilizers and required cross bracing be installed during ection in accordance with Stabilizer Installation guide. truss ,action, REACTIONS (lb/size) 5=448/0.8-0 (min. 0-1-8), 2=565/0-8-0 (min. 0-1-8) Max Horz 2=332(LC 4) Max Uplift 5=785(LC 4). 2=-1125(LC 4) Max Gray 5=531(LC 2), 2=674(LC 2) FORCES (Its) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown. TOP CHORD 2-3=-1072/1351, 4-5=-184/350 BOT CHORD 2-8=-1428/973, 7-8=-1428/973, 6-7=-1425/978, 6-9=1425/978, 5-9=1425/978 WEBS 3-7=0296, 3-5=991/1445 NOTES 1) Wind: ASCE 7-05; 150mph (3-second gust); TCDL=4.2psf BCDL=3.Opsf; h=18ft; Cat. 11; Exp C; enclosed; MWFRS (low-rise) gable end zone; Lumber DOL=1.33 plate grip DOL=1.33 2) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord , any other members. and 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 785 lb uplift at joint 5 and 1125 Ito uplift at joint 2. Q ,�� O >I N VF % 7) This truss has been designed for a moving concentrated load of 200.O1b live located at all mid panels and at all panel points along the Bottom Chord, A f -• •N nonconcurrent with any other live loads. �� G• design of this truss. ,O ' �� E S� • • 'ice 8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and :� o LOAD CASE(S) Standard N 6 818 2 � s • . 1k T OF �441 ` O�. FL Cert. 6634 April 18,201 ®W5RMIdG-Verifyd-ignp.r t—and RPA N07ES OPr7NISANDrXCLUDED MITEKREPERRMCS PAGE MTI-7473 rev,10-'08BEFORE USB. R' C■� Iva Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design paromenters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown bracing to insure during construction is the respomibillity of the MiTek' is for lateral support of individual web members only. Additional temporary stability erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding aw...a e. rn.... fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute. 781 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610-4115 Job Truss Truss Type RON -KLEIN RE-ROOFT4055677 22137 CO3 :���22137-KLEIN, Common Trussfe a ce o to al East Coast Truss, FORT PIERCE, FL. 34946 7.250 s Jan 28 2011 MiTek Indusldes, Inc. Mon Apr 18 14:46:23 2011 Page 1 - ID:ZycEGXaGi5uaivl hsBRj37zPYdX-ewv4ApBgJhl xVgOeOGeJvzpchyAl00HtgOmX4TzPTA_ -2-0-0 8-8-0 17A-0 2-0-0 8-8-0 8-8-0 Scale = 1:31.0 7x6 = 3 4 2 ILA 6 5 7 4x4 = 5x5 4x4 = = 17-4-0 8-8-0 8.8-0 Plate Offsets X 2:0-4-0 D-0.2 4:0-4-0 0.0-2 5:0-2-6 0.3-4 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Udefl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.57 Vert(LL) -0.28 4-5 >710 240 MT20 2441190 TCDL 7.0 Lumber Increase 1.25 BC 0.57 Vert(TL) -0.38 4-5 >520 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.09 Horz(TL) -0.03 4 n/a Na BCDL 5.0 Code FBC20071TP12002 (Matrix) Weight: 76 lb FT = 20% LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 5-7-11 oc bracing. WEBS 2 X 4 SYP No.3 MiTek recommends that Stabilizers and required cross bracing be installed during rection in accordance with Stabilizer Installation guide. truss erection. REACTIONS (lb/size) 4=443/0-8-0 (min. 0-1-8), 2=660/0-8-0 (min. 0-1.8) ' Max Horz 2=146(LC 4) Max Uplift4=-698(LC 7). 2=1063(LC 6) Max Grav 4=525(LC 2), 2=668(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1165/1361, 3-4=-1149/1320 BOT CHORD 2-6=-1150/1068, 5-6=-1150/1068, 5-7=1150/1068, 4-7=-1150N068 WEBS 3.5=0/296 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. 11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 3) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 4) This truss has been designed for a 10.0 pet bottom chord live load nonconcurrent with any other live loads. 5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3.6-0 tall by 2-0.0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 698 lb uplift at joint 4 and 1063 lb uplift at joint 2. `11 1 If fill,. 7) This truss has been designed for a moving concentrated load of 200.01b live located at all mid panels and at all panel points along the Bottom Chord, noncencurrenl with any other live loads. t� I "Semi fixity in the analysis and design of this truss.C'E'N 8) -rigid pitchbreaks including heels" Member end model was used I� J ••� �•••� LOAD CASE(S) Standard : N 68182 T O F 0�.. 1. FL Cert. 6634 April 18,201 A WARPUN0, - Verify design pm-.,iwa and READ NO7ES ON THIS AM INCLUDED MT7FX PEFERBNCB PA GB N177.7473 rea. 10.'08 BEFORE USE. Design valid for use only with MTek connectors. This design is based only upon parameters shown, and is for an individual building component. F■■��YYF� Applicability of design paramenters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown temporary bracing to insure stabilityduring construction is the responsibillity, of the MiTek` is for lateral support of individual web members only. Additional erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding eow 4 m P n.on.. fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610-4115 Job Truss Truss Type City Ply 22137 - KLEIN, RON - KLEIN RE -ROOF T4055678 22137 C04G Hip Truss 1 1 Job Reference o fo a East Coast Truss, FORT PIERCE, FL. 34946 7.250 s Jan 28 2011 MiTek Industries, Inc. Man Apr 18 14:46:24 2011 Page 1 ID:ZycEGXaGiSuaivl hsBRj37zPYdX-66TS09C I4_906_zgyz9YSAL14MPv7jH132W4bvzPT9Z -2-0-0 7-0-0 10-4-0 17-4-0 19-4-0 2-0-0 7-0-0 3-4-0 7-0-0 2-0-0 Scale = 1:34.3 5x10 MT18H = 5x10 MT18H = 3 9 4 2 SE 5 "N. 6 I6 — 10 8 11 7 12 4x12 3x8 I I 5x10 MT18H = i 7-0-0 10-4-0 17-4-0 4x12 = 7-0-0 3-4-0 7-0-0 Plate Offsets MY): : 3:0-5-4 0-3-0 4:D-5-4 0-30 :0.5-0 0-3-0 LOADING (psf) SPACING 2-D-0 CSI DEFL in (loc) Udell Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.65 Vert(LL) 0.52 7-8 >385 240 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.93 Vert(TL) -0.51 7-8 >392 180 MT18H 244/190 BCLL 0.0 ' Rep Stress Incr NO WB 0.56 Horz(TL) -0.16 5 n/a n/a BCDL 5.0 Code FBC20071TPI2002 (Matrix) Weight: 87 lb FT=20% LUMBER BRACING TOP CHORD 2 X 6 SYP SS TOP CHORD Structural wood sheathing directly applied or 3-2-0 oc purlins. BOT CHORD 2 X 4 SYP SS BOT CHORD Rigid ceiling directly applied or 2-4-10 oc bracing. WEBS 2 X 4 SYP No.3 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection In accordance with Stabilizer Installation guide. REACTIONS (lb/size) 2=1406/0-8-0 (min. 0-2.6), 5=1406/0-8-0 (min. 0-2-6) Max Harz 2=109(LC 4) Max Uplift 2=2583(LC 6), 5=-2583(LC 7) Max Grav 2=2002(LC 18), 5=2002(LC 21) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-6580/6907, 3-9=-6474/6841, 4.9=-6474/6841, 4-5=-6605/6930 BOT CHORD 2-10=-6575/6320, 8-10=-6575/6320, 8-11=-6666/6455, 7-11=-6666/6455, 7-12=-6520/6345, 5-12=-6520/6345 WEBS 3-8=-1180/1741, 4-7=-1227/1663 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf, h=1 Bft; Cat, Il; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 3) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. • bottom in a 3-6-0 tall by 2-0-0 wide will fit between the bottom chord 7) This truss has been designed for a live load of 20.Opsf on the chord all areas where rectangle 1 , 1 and any other members: 5. , ♦♦`V �/ 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 2583 lb uplift atjoint 2 and 2583 Its uplift atjoint load 200.DIb live located and at all along the Bottom Chord, ♦ AQv OP, •'' • • • C 9) This truss has been designed for a moving concentrated of at all mid panels panel points nonconcurrent with any other live loads. ♦♦ ,♦ •• ••�• 10) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. ` 11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 103 lb down and 261 Its up at 7-0-0, and 103 lb down and 251 r`i 68182 �� .. lb up at 8-8-0, and 103 lb down and 251 lb up at 10-4-0 on top chord, and 1419 lb down and 1228 lb up at 7-0-0, and 170 lb down at 8-8-0, and 1419 lb down * �• and 1228 Ito up at 10-3-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 12) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (8). LOAD CASE(S) Standard i •. T O F .•,1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) •! i O Vert: 1-3=-44, 3-4=44, 4.6=-44, 2-5=-10 �j •• P •• Concentrated Loads (lb) Vert: 3=-85(B) 4=-85(B) 8=-716(B) 7=-715(B) 9=-85(B) 11=21(B) • Q ,•• • • � ♦� I, SS ♦♦ FL Cert. 6634 April 18,2011 ® WARNING - Verify design p---ters and READ NOTES ON THIS AND TNCLUDED MITEKREFSRENCS PAGE M I.7473 reo. I0-'08 BEFORE USE. *� � Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and Is for an Individual building component. Mal Applicability of design parameniers and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding MiTek' fabrication, quality control, storage, delivery, erection and bracing. consult ANSI/TPII Qualify CrBerla, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312. Alexandria, VA 22314. Tampa, FL 33610-4115 Job Truss Type Qly Ply 22137 - KLEIN, RON - KLEIN RE -ROOF T4055679 22137 [,ulss 0 Monopitch Truss 3 1 Job Refere ce o llonal East Coast Truss, FORT PIERCE, FL. 34946 7.2,90 s Jan 28 2011 MiTek Industries, Inc. Mon Apr 18 14:46:25 2011 Page 1 ID:ZycEGXaGi5uaivl hsB Rj37zPYdX-aJ 1 rbU DW flHfkBYOWhhn?Ou?Umt6sC5AliFe7MzPT9y -2-0-0 6-8-8 12-7-8 2-0-0 6-8-8 5-11-0 Scale = 1:24.4 3x4 = 74 = 4 3x4 3 A' ,S 2 8r d 9 6 10 5 3x4 = 1x4 II 6-8-8 12-7-8 3x6 = r 5-11-0 181 LOADING (pst) SPACING 2-0-0 CSI DEFL in (loc) Udell Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.35 Vert(LL) -0.12 2-6 >999 240 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.42 Vert(TL) -0.17 2.6 >881 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.39 Horz(TL) -0.02 8 Na Na BCDL 5.0 Code FBC2007/TP12002 (Matrix) Weight: 72 lb FT = 20 LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oopudins, except end verticals. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-14 oc bracing. WEBS 2 X 4 SYP No.3 MiTek recommends that Stabilizers and required cross bracing be installed during OTHERS 2 X 4 SYP No.3 truss erection in accordance with Stabilizer Installation quide. REACTIONS (lb/size) 2=440/0-B-0 (min. 0-1-8).8=303/0-3-8 (min. 0-1.8) Max Horz 2=400(LC 4) Max Uplift2=-890(LC 4), 8=-553(LC 4) Max Grav 2=527(LC 2). 8=358(LC 2) FORCES (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-777/858, 5-7=-314/305, 4-7=-314/305 BOT CHORD 2-9=-1058/704. 6-9=-1058/704, 6-10=-10581704, 5-1 0=1 0581704 WEBS 3-6=0/261, 3-5=-682/1024 NOTES 1) Wind: ASCE 7-05; 150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat 11; Fxp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 2) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Bearing at joint(s) 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 890 lb uplift at joint 2 and 553 lb uplift at joint 8. This dfor moving concentrated load of 2DO.Olb live located at all mid panels and at all panel points along the Bottom Chord, 7) truss hasdeothsigned ^1 `, N 1 ,�� l ive non with any 8) "Semi including heels" Member end fixity model was used In the analysis and design of this truss. ``,,�� ,, •' . r`' -rigid pitchbreaks ,, () Ci• E N S�.• ��i •1."\'� LOADCASE(S) Standard N 68182 T OF .� O�.• • ��� S• 10PQ�1, FL Cert. 6634 April 18,201 ® WARNfNO - Verify design P-ametc . and REdD N07ES ON 7EIS AND rRCLUDED ATIR CREFERF-NCE PAGE MA-7473 ram. 20-'08 BEFORE USE, Design valid for use only with MiTek connectors. This design is based only upon parameters shown. and is for an individual building component. � Applicability of design paromenters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown is for lateral suFport of individual web members only. Additional temporary bracing to insure stability during construction 4 the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding MiTek' w.A,o a -o .a fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610-4115 Job uss Truss Type City Ply 22137 - KLEIN, RON - KLEIN RE -ROOF T4055680 22137 [DrO2 Half Hip Truss 1 1 Job Refere ce o Tonal East Coast Truss, FORT PIERCE, FL. 34946 7.250 s Jan 28 2011 MiTek Industries, Inc. Mon Apr 18 14:46:25 2011 Page 1 - ID:ZycEGXaGi5uaivl hsBRj37zPYdX-aJ1 rbUDwrl Hfk8YOWhhn70uxgmmNsEUAliFe7MzPT9y -2-0-0 11-D-0 12-7-8 11-0-0 1-7-8 Scale = 1:24.7 6x12 = 3x4 = 4 6x8 I I 3 71 2 8 v 1d 9 6 10 5 1x4 II 3x4 = 3x8 = 11-0-0 12-7-8 r 11-0-0 1-7-8 Plate Offsets X : 2:0-2-8 0-1-8 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deg Ltd PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.60 Vert(LL) -0.43 2-6 >339 240 MT20 2441190 TCDL 7.0 Lumber Increase 1.25 BC 0.85 Vert(TL) -0.66 2-6 >222 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.31 Horz(TL) -0.01 8 n/a Na BCDL 5.0 Code FBC2007fTP12002 (Matrix) Weight: 68 lb FT=20% LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 8-8-5 oc bracing. WEBS 2 X 4 SYP No.3 MiTek rewmmends that Stabilizers and required cross bracing be installed during rection in accordance with Stabilizer Installation guide. OTHERS 2 X 4 SYP No.3 truss erection. REACTIONS (lb/size) 2=440/0-8-0 (min. 0-1-8), 8=303/0-3-8 (min. 0-1-8) Max Harz 2=368(LC 4) Max Uplift 2=-897(LC 4), 8=-545(LC 4) Max Grav 2=527(LC 2), 8=358(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-409/330, 5-7=-990/593, 4-7=-990/593 ' BOT CHORD 2-9=-464/326, 6-9=-464/326, 6-10=-460/336, 5-10=-460/336 WEBS 3-6=0/602, 3-5=-772/1013 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 3) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord' and any other members. formula. Building designer should verify capacity of bearing surface. N V�c� ��j� 7) Bearing at joint(s) 8 considers parallel to grain value using ANSI/TPI 1 angle to grain 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 897lb uplift at joint 2 and 545lb uplift atjoint 8. `��� PQv O ���� 9) This truss has been designed for a moving concentrated load of 200.0Ib live located at all mid panels and at all panel points along the Bottom Chord, ,� *� G E N S •, , nonconcument with any other live loads. •. i 10) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. N 68182 LOAD CASE(S) Standard * • ' • T O F 41J m O'.• � 1• � 01 1111111, FL Cert. 6634 April 18,201 ® WARMNG-Verify driyn pa—wwimw and READ NOTES ON THIS AND INCLUDED ]UTIRKREFERENCE PAGE AH-7473 rev. 10-108 BEFORE USE. Design for with MiTek connectors. This design is based any upon parameters shown, and is for an individual building component. — E■3 valid use only Applicability of design paramenters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown k the the MiTek is for lateral support of individual web members only. Additional temporary bracing to insure stabilityduring construction responsibillity of erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610-4115 Job Truss Type Oty Ply - KLEIN. RON - KLEIN RE -ROOF F221,3 T4055681 22137 [russ 03 Half Hip Truss 1 1 f re ceopdo a East Coast Truss, FORT PIERCE, FL. 34946 7.250 s Jan 28 2011 MiTek Industries, Inc. Mon Apr 18 14:46:26 2011 Page 1 - ID:ZycEGXaGiSuaivl hsBRj37zPYdX-2VbDpgEYccP WM16D3000XbR90ABybioJWM?BfozPT9x _2-0-0 9-0-0 12-7-8 2-0-0 9-0-0 3-7-8 Scale = 1:24.6 6x8 = 3x4 = 4 6x8 I 3 2 81 n d 9 6 10 5 1x4 II 3x4 = 4x4 = 9-0-0 12-7-8 i 9-0-0 3-7-8 Plate Offsets X 2:0-4-0 0-0-2 3:a5.4 0-3-8 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.43 Vert(LL) -0.27 2-6 >544 240 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.57 Vert(TL) -0.38 2-6 >379 180 BCLL 0.0 ' Rep Stress Incr YES WE 0.24 Horz(TL) -0.01 8 Na n/a BCDL 5.0 Code FBC20071TPI2002 (Matrix) Weight: 67lb FT=20% LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 7-3.15 or bracing. WEBS 2 X 4 SYP No.3 MiTek recemmends that Stabilizers and required cross bracing be installed during OTHERS 2 X 4 SYP No.3 truss erection in accordance with Stabilizer Installation quide. REACTIONS (lb/size) 2=440/0-8-0 (min. 0-1-8), 8=303/0-3-8 (min. D-1-8) Max Harz 2=314(LC 4) Max Uplift 2=-909(LC 4), 8=-533(LC 4) Max Grav 2=527(LC 2), 8=358(LC 2) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-566/613, 5-7=-473/326, 4-7=-473/326 BOT CHORD 2-9=-706/487, 6.9=-706/487, 6-10=-703/493, 5-10=-703/493 WEBS 3-6=01282, 3-5=558(/84 NOTES 1) Wind: ASCE 7-05; 150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opst, h=18ft; Cat 11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-&0 tall by 2.0-0 wide will fit between the bottom chord and any other members. ANSIITPI 1 to formula. Building designer should verify capacity of bearing surface. t 6) Bearing at joint(s) 8 considers parallel to grain value using angle grain 8. %%% IN. I V• 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 909 lb uplift at joint 2 and 533 lb uplift atjoint 8) This truss has been designed for a moving concentrated load of 2DO.Olb live located at all mid panels and at all panel points along the Bottom Chord, %%% PQ C• ♦ 5���� E N • nonconcurrent with an other live loads. ,,, J •• • ` •', 9) "Semi -rigid pitchbreaks including heels" Member and fixity model was used in the analysis and design of this truss. ; „ LOAD CASEStandard � N 68182S) ' = * � * ► T OF '•� O�. / ►Illnl+��`� FL Cert. 6634 April 18,201 ®UVARM14O.7-ify design pmnmeiws and READ N07ES ON 1NIS AND INCLUDED W7EKREFERENCB PAGE141-7473 nea. 10-'08 BEFORE USE. *�*R Design valid for use only with MiTek connectors. This design a based only upon parameters shown, and is for an Individual building component. my so Applicability of design paramenters and proper Incorporation of component is responsibility of building designer- not truss designer. Bracing shown a the the MiTek' is for lateral su port of individual web members only. Additional temporary bracing to Insure stabilityduring construction responsibillity of erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 761 N. Lee Street, Suite 312. Alexandria, VA 22314. Tampa, FL 33610-4115 Job Truss Truss Type City Ply 22137 - KLEIN, RON - KLEIN RE -ROOF T4055682 22137 D04G Half Hip Truss 1 1 Job I erence (optional East Coast Truss, FORT PIERCE, FL. 34946 7.250 s Jan 28 2011 MiTek Industries, Inc. Mon Apr 18 14:46:27 2011 Page 1 ID:ZycEGXaGi5uaivl hsBRj37zPYdX-Wh9bOAEBNvXNzShPd5jF4pzFXZSCK_mTIOkkCEzPT9w _2_0_0 7-0-0 12-7-8 2_0_0 7-0-0 S-7-8 Scale = 1:24.4 3x4 = 5x12 = 4 - 6x8 II 3 9 10 2 8 d 11 6 12 13 14 5 4x6 = 3x8 II 6x10 = i 7-0-0 7-0-0 Plate Offsets X 3:0-9-0 0-30 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Vdefl Lid PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.77 Vert(LL) 0.21 2.6 >691 240 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.89 Vert(TL) -0.27 2-6 >544 180 BCLL 0.0 ' Rep Stress Incr NO WB 0.96 Horz(TL) -0.06 8 n/a Na BCDL 5.0 Code FBC2007/TP12002 (Matrix) Weight: 67 lb FT = 20 LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 4-3-0 oc purlins, except end verticals. BOT CHORD 2 X 4 SYP No.1 BOT CHORD Rigid ceiling directly applied or 3-3-7 oc bracing. WEBS 2 X 4 SYP No.3'Except' WEBS 1 Row at midpt 3-5 4-5: 2 X 4 SYP No.2 MiTek recommends that Stabilizers and required cross bracing be installed during OTHERS 2 X 4 SYP No.3 truss erection in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 2=835/0-8-0 (min. 0-1-8), 8=921/0-3-8 (min. 0-1-8) Max Harz 2=260(LC 4) Max Uplift 2=-1614(LC 4). 8=-1603(LC 4) Max Grav 2=1109(LC 13), 8=1493(LC 15) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3236/3381, 3-9=-433/435, 9-10=-433/435, 4-10=-433/435, 5-7=1085/1362, 4-7=-1085/1362 BOT CHORD 2-11=-3338/3099, 6-11=-3338/3099, 6-12=-3426/3240, 12-13=-3426/3240, 13-14=-3426/3240, 5-14=-3426/3240 WEBS 3-5=-1136/1806, 3-5=-3032/3178 NOTES 1) Wind: ASCE 7-05; 150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat 11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent vrith any other live loads. p l 1 1111 fit between the bottom 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will chord `1 ` I V and any other members. `T�1.+i1J 6) Bearing atjoint(s) 8 considers parallel to grain value using ANSI/TP1 1 angle to grain formula. Building designer should verify capacity of bearing surface. ,%,OI"' �� 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1614 lb uplift at joint 2 and 1603 lb uplift at joint B. ,� , • G E•IN •�• F • ••, 8) This truss has been designed for a moving concentrated load of 200.O1b live located at all mid panels and at all panel points along the Bottom Chord, ; noncencurrent with any other live loads. N 68182 9) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 103 lb down and 251 It, up at 7-0-0, and 103 lb down and 251 - lb up at 9-0-12, and 103 lb down and 251 lb up at 11-0-12 on top chord, and 1419lb down and 1228 lb up at 7-0-0, and 170 lb down at 9-0-12, and 170 lb down e at 11-D-12 on bottom chord. The designtselection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 0 A,P •. 1) Lumber crease=1.25, Plate Increase=1.25 Q N UnforrmLoads (plyar: .. Vert: 1-3=-44, 3-4=44, 2-5=-10 �j/ V S • • • • • •' ,� Concentrated Loads (lb) /// N A L E %�% 14=-21(B){1{�� Vert: 6=-716(B) 3=-85(8) 9=-85(B) 10=-85(B) 12=-21(B) FL Cert. 6634 April 18,201 ®WARNING- Vesijy designpara d—and READ N07ES ON7NI8 AND INCLUDED M YRICREFERENCE PAGEMI-7473 ren. 20-'08 BEFORE USE. 1�*� Design valid for use only with M1ek connectors. This design Is based only upon parameters shown, and Is for an individual building component. Applicability of design paramenters and proper incorporation of component 4 responsibility of building designer- not truss designer. Bracing shown M is for lateral support of individual web members only• Additional temporary bracing to insure stablity.dudng construction is the responsibillity of the iTek' erector. Addifional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding a ........a fabrication, quality control, storage, delivery, erection and bracing, consult ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Solety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610-4115 Job Truss Oly PN 22137 - KLEIN, RON - KLEIN RE-ROOFT4055683 22137 E01G Frus,,Type EIATRUSS 2 1 Job Re erenca o Tonal East Coast Truss, FORT PIERCE, FL. 34946 7.250 s Jan 28 2011 MiTek Industries, Inc. Mon Apr 18 14:46:28 2011 Page 1 ID:ZycEGXaGi5uaivlhsBRj37zPYdX-_ ujzDWFpBDfEbcGbBpEUcOWQ2zm23afc_gUlkhzPT9v 16-0-0 -2-0- 0-9-0 - 0 B- ill - 15-1-0 1 - 1 8-0-0 2-0-0 0-9-4 3-7-6 3-7-6 3-7-6 3-5-14 0- -6 2-o-0 0-9-0 Scale = 1:32.7 - 5x5 = 4 3x4 3x4 zz 3 5 6x16 = Sx12 = g 14 2 13 7 9 N 5x8 = 12 11 15 16 8 10 7x6 zz 4x6 i6-0-0 0-9-0 44-10 8-0-0 11-76 15-1-0 _ 15- 1--2� 0.9-0 3-7-6 3-7-6 3-7-6 3-5-14 008 0-9-0 Plate Offsets X Y : 2:0.3-4 0-2-8 6:0.8-12 Ed e LOADING (psf) SPACING 2.0-0 CSI DEFL in (loc) I/deb Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.65 Vert(LL) -0.23 9-10 -816 240 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.98 Vert(TL) -0.30 9.10 >604 180 BCLL 0.0 ' Rep Stress Incr NO WB 0.34 Horz(TL) -0.05 14 n/a Na BCDL . 5.0 Code FBC2007/TP12002 (Matrix) Weight: 102 lb FT'=20% LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD 2 X 4 SYP No.3 BOT CHORD Rigid ceiling directly applied or 5-3-14 oc bracing. WEBS 2 X 4 SYP No.3 *Except* MiTek recommends that Stabilizers and required cross bracing be installed during 6-8: 2 X 6 SYP No.2, 2-10: 2 X 4 SYP No.2 truss erection in accordance with Stabilizer Installation guide. OTHERS 2 X 10 SYP No.2 . REACTIONS (lb/size) 13=544/0-8-0 (min. 0-1-8), 14=1240/0-8-0 (min. 0-1.8) Max Harz 13=-140(LC 5) Max Uplift 13=-1081(LC 6), 14=-2235(LC 7) Max Grav 13=650(LC 2), 14=1478(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD. 2-3=-217/304, 3-4=-1133/1359, 4-5=113411374, 5-6=-477/668, 8-12=-1489/1127, 6-12=-1489/1127, 10-11=A32/357, 2-11=432/357 BOT CHORD 10-15=-1042/826, 9-15=-1038/833, 9-16=1180/1003, 8-16=-1184/995 WEBS 4-9=-341/373, 3-9=-232/334, 3.10=-83511133, &8=-652/826 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 3) This truss has been designed for basic loadcombinations, which include cases with reductions for multiple concurrent live loads. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 11111 f / 5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-5-0 tall by 2-0-0 wide will fit between the bottom chord ,,���^1 11 ^ tIt'll, V I V V , and any other members. lr� and ` 6) Bearing at joint(s) 13, 14 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. ,1� O P • �� ��� 14. ' • G•E•N 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1081 lb uplift at joint 13 and 2235 lb uplift at joint ,� , S • •••, 8) This truss has been designed for a moving concentrated load of 200.01b live located at all mid panels and at all panel points along the Bottom Chord, : •� r nonconcument with any other live loads. N 68182 9) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. : r 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 907 lb down and 1259 Ib up at 15-0-0 on bottom chard. The �• : 'rlf designtselection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). •' -!�• LOAD CASE(S) Standard !� T O F :•/I. 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 lo0. W: • Unifo7m Loads (plf) �� • Q`•.' _ Vert: 1-2=44, 24=44, 4.6=-44, 6-7=-44, 9-10=10, 8-9=-10 I \ Concentrated Loads (Ib) j� S (1 ' • • • • • • \ % Vert: 8=-764(F) � /111111111�� FL Cert. 6634 April 18,201 ®WARNING- Verify dasignparamet- aed READ N07ES ON THISANII INCLUDED 1ffl7g3KRFF8RENCBPAGB MI.7473 new. 10•'08 BEFORE USE. This design a based upon shown, and is loran individual building component. ��• Design valid for use only with MiTek connectors. only parameters Applicability of design paromenters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibillity of the Additional bracing of the overall structure is the responsibility of the building designer. For general guidance regarding MiTek• e w .,+o e•a� .. erector. permanent fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute. 781 N. Lee Street. Suite 312, Alexandria, VA 22314. Tampa, FL 33610-4115 Job Truss Truss Type Qty ply 22137 - KLEIN, RON - KLEIN RE -ROOF T4055684 22137 E02 SPECIAL TRUSS 3 1 Job Reference (optional East Coast Truss, FORT PIERCE, FL. 34946 7.250 is Jan 28 2011 MiTek Industries, Inc. Mon Apr 18 14:46:29 2011 Page 1 ' ID:ZycEGXaGi5uaivl hsBRj37zPYdX-S4HLRsGRvXn5DIrnlwj9E3ddNE?ow1 mCKDrG7zPT9u -2-0-0 0-9-0 4-5-8 8-0-0 15-0.8 2-0-0 0-9-0 3-8-4 3-6-8 7-0-8 Scale = 1:28.7 5x6 = 4 3x4 3 5x6 5x12 = 5 2 7 m N 5x6 = 9 11 12 I 6 4x6 8 3x4 II r>_oa 8-0-0 15-0-8 0-9-4 7-2-12 7-0-8 Plate Offsets X 2:03-4 0-2-8 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.54 Vert(LL) -0.20 7.8 >881 240 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.49 Vert(TL) -0.27 7-8 >654 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.78 Horz(TL) -0.04 6 Na n/a BCDL 5.0 Code FBC2007/rPI2002 (Matrix) Weight: 91 lb FT=20% LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 6-6-15 oc bracing. WEBS 2 X 4 SYP No.3 *Except" MiTek recommends that Stabilizers and required cross bracing be installed during 5-6,2-8: 2 X 4 SYP No.2 truss erection. rection in accordance with Stabilizer Installation guide. OTHERS 2 X 10 SYP No.2 REACTIONS (lb/size) 6=385/Mechanical, 10=498/0-8-0 (min. 0-1-8) Max Harz 10=181(LC 4) Max Uplift6=600(1_C 7). 10=-1009(LC 6) Max Grav 6=456(LC 2). 10=596(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 3-4=-938/1175, 4-5=-972/1131, 5-6=-436/639, 8-9=-366/319, 2-9=-366/319 BOT CHORD 6-11=-917/706, 7-11=-9141713 WEBS 4-7=-98/281, 5-7=-922/817, 3-7=-248/258, 3-8=703/985 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 150mph (3-second gust); TCDL=4.2psf; BCDL=3.0psf; h=18ft; Cat. 11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 3) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord' and any other members. for truss to truss 1 1 1� 1 O.V l' V �� 6) Refer to girder(s) connections. 7) Bearing at joint(s) 10 considers parallel to grain value using ANSINPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. ♦♦,' OP• . 4, I� 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 600 Its uplift at joint 6 and 1009 lb uplift at joint 10. ♦♦♦ `♦ , • G•E•N S • ��' • F • ••, 9) This truss has been designed for a moving concentrated load of 200.OIb live located at all mid panels and stall panel points along the Bottom Chord, ` •• nonconcurrent with any other live loads. "Semi design this truss. N 68182 10) -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and of LOAD CASE(S) Standard T OF �'J/-Z •4U1 1• ♦ C? FL Cert. 6634 April 18,201 ®WARNING-Vwifyd-iyrtparamer:ernrand READ NOTES ON THIS AND INCLUDED 1197EKREPERENCB PAGE MI.7473 r". 10-'08 BEFORE USB. *R• Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. �F�Y�"q■■■ Applicability of design paramenters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown is the the MiTek' is for lateral support of individual web members only. Additional temporary bracing to insure stabilityduring construction responsibillity of erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding paw ,,,o -- to brication, quality control, storage, delivery, erection and bracing, consult ANSIITP11 Quality Criterlo, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Informatlon available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610.4115 Job Truss Truss Type City Ply 22137 - KLEIN, RON - KLEIN RE -ROOF T4055685 22137 E03G HIP TRUSS 2 1 Joba ere ce o do al East Coast Truss, FORT PIERCE, FL. 34946 7.250 s Jan 28 2011 MiTek industries, Inc. Mon Apr 18 14:46:31 2011 Page 1 - ID:ZycEGXaGi5uaivl hsBRj37zPYdX-PS06sYIhRB1 pS3?AsxnBEfBxDBtXGgV3geiyL?zPT9s -2-0-0 0-9-4 3-1a10 7-0-0 9-0-0 12-1-s _ _ _ 15-2-12 16-0.0� 18-0-0 - 2-0-0 90.9, 3-1-6 3-1� 2-0-0 3-1-6 3-1-6 ' 0-9-4 ' 2-0-0 Scale: 3/8"=1' - 6x10 6x6 = 4 5 5x8 5x8 3 6 Sx12 = Sx12 = 2 7 15 1 8 11 18 10 d, 13 5x8 = 5x12 = 14 17 19 9 12 5x5 5x6 3-10-10 7-1-8 B-10.8 12-1-6 15-2-12 16-0.0 0-9-4 3-1-6 3-2-14 1-9-0 3-2-14 3-1-8 0-9-4 Plate Offsets X 2:0-3-4 a2-8 :0.3-4 a2-8 LOADING (psf) SPACING 2-0-0 CSI DEFL in (too) Udeft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.66 Vert(LL) 0.21 10-11 >860 240 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.61 Vert(TL) -0.22 11-12 >821 180 SCLL 0.0 ' Rep Stress Incr. NO WB 0.78 Horz(fL) -0.10 16 Na Na BCDL 5.0 Code FBC2007/TPI2002 (Matrix) Weight 103 lb FT=20% LUMBER BRACING TOP CHORD 2 X 6 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 4.8-10 oc pudins, except end verticals. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 3-2-2 oc bracing. WEBS 2 X 4 SYP No.3 .Except• MiTek recommends that Stabilizers and required cross bracing be installed during 2-12,7-9: 2 X 4 SYP No.2 truss erection in accordance with Stabilizer Installation nuide. OTHERS 2 X 10 SYP No.2 REACTIONS (lb/size) 15=914/a8-0 (min. 0-1-8), 16=91410-8-0 (min. D-1-8) Max Harz 15=129(LC 4) Max Uplift 15=-1788(LC 4), 16=-1788(LC 5) Max Grav 15=1089(LC 2), 16=1089(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-293/487, 3-4=-2706/3936, 4-5=2649/3901, 5-6=-2714/3938, 6-7=-293/433, 12-13=-1131/795, 2-13=-1131/795,9-14=-1096/794, 7-14=-1096/794 BOT CHORD 12-17=-2368/1639, 11-17=-2362/1644, 11-18=3756/2641, 10-18=-3756/2640, 10-19=-2267/1642, 9-19=-2273/1637 WEBS 3-11=-1472/1059, 4.11=-626/547, 5-10=-623/450, 6-10=-153711071, 3-12=-1748/2598, 6-9=-1745/2512 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cal. II; Esp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 3) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 1111111 !! / 4) Provide adequate drainage to prevent water ponding. live load any other live loads. I V ✓ �� 5) This truss has been designed for a 10.0 psf bottom chord nonconcurrent with ,�OnGO • � 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord S"` � , ,� C NS and any other members. E �I , • • � • • 7) Bearing at joint(s) 15. 16 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. ��` ; 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1788 lb uplift at joint 15 and 1788 lb uplift at joint 16. N 68182 9) This truss has been designed for a moving concentrated load of 200.01b live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. 10) Girder carries hip end with 7-0-0 end setback. 11) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. load(s) 411 lb down 644 lb up at 8-10-8, and 411 lb down and -9 12) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated and 644 lb up at 7-1-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. T F �• • 13) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). O••� ` �I� •• Q P�•• ���` LOAD CASE(S) Standard ` 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 �j� V ' • • • • •' S % Uniform Loads (plf) Vert: 1-2=44, 2-4=44, 4-5=-92(F=-48), 5-7=-44, 7-8=-44, 11-12=-10, 10.11=-21(F=-11), 9-10=-10 I I! / 111111111, Concentrated Loads (lb) Vert: 11=-347(F) 10=-347(F) FL Cert. 6634 April 18,201 ® WARMNG - 7 fy deaign poo-t- and READ N07ES ON 7EIS AND INCLUDED Ml7EKHEP&RP-NCE PAGE RU-7473 r .. 10-'08 BEFORE USE. *� • Design valid for use any with M7ek connectors. This design is based only upon parameters shown, and is for an individual building component. ■■••�YYI7■■■ Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown the MiTek° is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibility of Addi bracing of the overall structure is the responsibility of the building designer. For general guidance regarding -.1. - _-.- erector. tonal permanent fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610-4115 Job Truss Truss Type Qly Ply 22137 - KLEIN, RON - KLEIN RE -ROOF T4055666 22137 FG01 Flat Truss 1 1 Job efere ce o tonal East Coast Truss, FORT PIERCE, FL. 34946 7.250 s Jan 28 2011 MiTek Industries, Inc. Mon Apr 18 14:46:32 2011 Page 1 ID:ZycEGXaGiSuaivl hsBRj37zPYdX-tfyU3uIJCS9g4DaMQfJQnsh3laFo?JyCvISVtSzPT9r 3-10-8 7-9-0 3-10-8 3-10-8 Scale = 1:14.4 4x6 = ^ 4x6 = 1x4 II 1 2 3 1 7 8 5 6x8 = 4 6 3x10 I 3x10 II 10-8 7-M 3-10-8 3-10-8 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Vdeft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.89 Vert(LL) 0.11 5 >796 240 MT20 2441190 TCDL 7.0 Lumber Increase 1.25 BC 0.48 Vert(TL) 0.09 5 -999 180 BCLL 0.0 ' Rep Stress Incr NO WB 0.64 Horz(TL) -0.00 4 n/a Na BCDL 5.0 Code FBC2007/TPl2002 (Matrix) Weight: 43 lb FT = 20% LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 4-6-9 oc purlins, except end verticals. BOT CHORD 2 X 6 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2 X 4 SYP No.3 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 6=764/Mechanical, 4=764/Mechanical Max Uplift6=-1259(LC 4), 4=-1259(LC 4) Max Grav 6=907(LC 2), 4=907(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1.6=-612/884, 1-2=-18D1/2490, 2-3=-1801/2490, 3-4=-612/884 BOT CHORD 6-7=-255/180, 5-7=-255/180, 5-8=-255/180, 4-8=-255/180 WEBS 1-5=-2335/1693, 2-5=-156/324, 3-5=2335/1693 NOTES 1) Wind: ASCE 7-05; 150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf, h=18ft; Cat II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1259 lb uplift at joint 6 and 1259 lb uplift at joint 4. along the Bottom Chord, 1 I I I I II 8) This truss has been designed for a moving concentrated load of 200.O1b live located at all mid panels and at all panel points `,�� ���♦♦ nonconcurrent with any other live loads. %%*% N VF /� 9) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. ffito load(s) 446 lb down and 607 lb up at 1-11-4, and 446 lb down and �OP601 10) Hanger(s) or other connection device(s) shall be provided sufficient support concentrated 607 Ib at 3-10-8, and 446 Ib down and 6071b up at 5-9-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. �� �� , • \ G.E N S� •.�• ♦0i up 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). : �•• lo N 68182 •; -, LOAD CASE(S) Standard * 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-44, 4-6=10 .� Concentrated Loads (lb) T O F Vert: 5=-375(F) 7=-375(F) 8=-375(F) . 0'.� .. I ♦♦♦'ASS• •.NA1-�'�.��, IlIfllilt FL Cert. 6634 April 18,2011 ® WARNING - Verify design parvmet— and READ NOTES ON 7YRS AND [MCLUDED M77EKREFERENCS PAOE M I.7473 rev. ZO '08 BEFORE USE, *R � Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. ■�•i121 Applicability of design paramenters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regardng MiTek' fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Crfieda, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610.4115 Job Truss Truss Type Oty PN 22137 - KLEIN, RON - KLEIN RE -ROOF T4055687 22137 FG02 Flat Truss 2 1 PIERCE, FL. 34946 1 3x4 = 2x4 114 LOADING (psf) SPACING 2-0-0 TCLL 20.0 Plates Increase 1.25 TCDL 7.0 Lumber Increase 1.25 BCLL 0.0 ' Rep Stress Incr NO BCDL 5.0 Code FBC2007/TPI2002 LUMBER TOP CHORD 2 X 4 SYP No.2 BOT CHORD 2 X 6 SYP No.2 WEBS 2 X 4 SYP No.3 ID:ZycEGXaGiSuaivl 22x4 II 3 4x4 = CSI DEFL in (too) Udell L/d TC 0.29 Ven(LL) -0.02 3-4 >999 240 BC 0.40 Vert(TL) -0.02 3-4 >999 180 WB 0.00 Horz(TL) -0.00 3 Na n/a (Matrix) REACTIONS (lb/size) 4=203/Mechanical, 3=193/Mechanical Max Uplift 4=371(LC 4). 3=-352(LC 4) Max Grav 4=367(LC 12), 3=355(LC 13) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown. Scale = 1:12.8 1 PLATES GRIP MT20 244/190 Weight: 23 lb FT = 20 BRACING TOP CHORD Structural wood sheathing directly applied or 3-8-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek rewmmends that Stabilizers and required cross bracing be installed during truss erection in accordance with Stabilizer Installation quide. NOTES 1) Wind: ASCE 7-05; 150mph (3-second gust); TCDL=4.2psf; BCDL=3.0psf; h=18ft; Cal. 11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever leftand right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 2) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 371 lb uplift at joint 4 and 352 lb uplift at joint 3. 8) This truss has been designed for a moving concentrated load of 200.0I1b live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. 9) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 252 lb down and 404 lb up at 1-9-4 on bottom chord. The designtselection of such connection device(s) is the responsibility of others. ``��, , 1 1 , I V !, �< 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). �>`O t�Qv � f......0 I� E N LOAD CASE(S) Standard , •�.�� G 1 1) Regular: Lumber Increase--1.25, Plate Increase=1.25 ♦` Uniform Loads N 68182 Vert: 1-2=-=-44, 3-4=10 ..^ * : Concentrated Loads (lb) Vert: 5=-212(8) T O F 0�. Al FL Cert. 6634 April 18,201, WERMNG - Verify design parametns and READ NOTES ON THIS ENO INCLUDED XITEK REFERENCE PAGE AW-7473 ren. 20.'08 BEFORE USE. R Design valid for use only with MiTek connectors. This design is based any upon parameters shown, and is for an individual building component. HVIp■ Applicability of design paramenters and proper incorporation of component is responsibirityof building designer - not truss designer. Bracing shown Is for lateral support of individual web members only. Additional temporary bracing to Insure stabilityduring construction is the responsibillity of the MiTek' erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding oer.,e..r ... fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610.4115 Job Truss e City Ply 22137 - KLEIN, RON - KLEIN RE -ROOF T4055688 22137 MV5 FValleyTruss 1 1 Job --------- East Coast Truss, FORT PIERCE, FL. 34946 7.250 s Jan 28 2011 MiTek Industries, Inc. Mon Apr 18 14:46:33 2011 Page 1 - ID:ZycEGXaGi5uaivlhsBRj37zPYdX-LrWSHDJxzlHXhN9Z MgfJ4DN6_cWkwDL7yC3PuzPT9q 5-0-8 5-0-8 Scale = 1:9.5 _ 2x4 II 2 1 4 3 3x4 2x4 II 0 5-0-8 LOADING (psf) SPACING 2-0-0 CSI DEFL in (too) Vdefi Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.31 Vert(LL) n/a - Na 999 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.39 Vert(TL) Na - Na 999 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 Na n/a BCDL 5.0 Code FBC2007/TPI2002 (Matrix) Weight: 14 lb FT = 20% LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 5-0-8 oc purlins, except end verticals. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2 X 4 SYP No.3 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 1=100/5-0-8 (min. 0-1-8), 3=100/5-0-8 (min. 0-1-8) Max Harz 1=100(LC 4) Max Uplift 1=161(1_C 4), 3=-186(LC 4) Max Grav 1=245(LC 12), 3=245(LC 13) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown. NOTES 1) Wind: ASCE 7-05; 150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat, 11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever leftand right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 2) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-&0 tall by 2-0.0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 161 lb uplift at joint 1 and 186 lb uplift atjoint 3. 7) This truss has been designed for a moving concentrated load of 200.OIb live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. 8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard ,�11111111!lII�� I N ���'',' Vo Go • N 68182 :J3 T OF .441 • • ,o ,�.01Sr!! N FL Cert. 6634 April 18,201 ®WARNING-VvijydcsiynPwn tnvand RIQA NOTES ON THIS AND INCLUDED 072K REFERENCE PAGE IM-7473 rea. 10.'08 BEFORE USE. Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stabilityduring construction isthe responsibillity of the MiTek erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding — _-.- fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality CrHerla, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610-4115 Job Tmss Truss Type Qty Py -KLEIN,RON -KLEIN RE-ROOFT4055664 F221,37 22137 MV7 ValleyTruss1fe ence o tlonal East Coast Truss, FORT PIERCE, FL. 34946 7.250 s Jan 28 2011 MiTek Industries, Inc. Mon Apr 18 14:46:34 2011 Page 1 - ID:ZycEGXaGi5uaivl hsBRj37zPYdX-pl4EUZKaj3PNJXkIX4LusHmTEOzBTNTVMcxcxKzPT9p 7-0-8 7-0-8 Scale = 1:12.8 4x4 I I 2 1 4 3 3x4 3x4 I 7-0-8 LOADING (psf) SPACING 2-0-0 CSI DEFL In (too) Vdefl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.61 Vert(LL) n/a - Na 999 MT20 2441190 TCDL 7.0 Lumber Increase 1.25 BC 0.36 Vert(rL) ' n/a - n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a Na BCDL 5.0 Code FBC2007/TP12002 (Matrix) Weight: 21 lb FT=20% LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2 X 4 SYP No.3 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 1=15417-0-8 (min. 0-1-8), 3=15417.0-8 (min. 0-1-8) Max Horz 1=154(LC 4) Max Uplift 1=-248(LC 4), 3=-286(LC 4) Max Gray 1=269(LC 12). 3=269(LC 13) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2.3=-141/280 NOTES 1) Wind: ASCE 7-05; 150mph (3-second gust); TCDL=4.2psf; BCDL=3.Opsf; h=18ft; Cat. 11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 2) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) • This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 248 lb uplift atjoint 1 and 286 Ito uplift at joint 3. 7) This truss has been designed for a moving concentrated load of 200.0Ib live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. "Semi in the design of this truss. 11 �, 8) -rigid pilchbreaks including heels' Member end fixity model was used analysis and ,1t,1 } N ////// I �/� LOAD CASE(S) Standard ♦,♦OP.Q'V /' ♦ C lo ` N 68182 T F �L ` ,441 . O�. FL Cert. 6634 April 18,2011 ® WARWNG- V.,4fy design par-ametmw and READ NOTES ON THIS AND INCLUDED MITEKREFERENCE PAGB MI-7473 rea. 10`08 BEFORE USE. *�• Design valid for use only with M1ek connectors. This design is based only upon parameters shown, and is for an Individual building component. i��iiip Applicability of design paramenters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall struciure is the responsibility of the building designer. For general guidance regarding MiTek` fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 781 N. Lee Street. Suite 312. Alexandria, VA 22314. Tampa, FL 33610-4115 Job Truss Truss Type Dry 22137 -KLEIN, RON -KLEIN RE -ROOF �Ply T4055690 22137 MV9 Valley Truss 1 1 Jo e e e ce o tional East Coast Truss, FORT PIERCE, FL. 34946 7.250 s Jan 28 2011 MiTek Industries, Inc. Mon Apr 18 14:46:34 2011 Page 1 ID:ZycEGXaGiSuaivl hsBRj37zPYdX-pl4EUZKaj3PNJXkIX4LusHmZM0?XTLCVMcxcxKzPT9p 9-0-8 _ 9-0-8 Scale: 3/4"=1' 2x4 II 3 1x4 II 2 1 Ll e 5 7 4 3x4 1x4 II 9-0-8 2x4 II 9-0-8 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.22 Vert(LL) n/a - Na 999 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.21 Vert(TL) Na - Na 999 BCLL 0.0 ' Rep Stress Incr YES WB 0.15 Horz(TL) 0.00 4 n/a Na BCDL 5.0 Code FBC2007/rP12002 (Matrix) Weight: 29 lb FT=20% LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2 X 4 SYP No.3 MiTek recommends that Stabilizers and required cross bracing be installed during OTHERS 2 X 4 SYP No.3 truss erection in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 1=8219-0.8 (min. 0-1-8), 4=82/9-0-8 (min. 0-1-8), 5=252/9-0-8 (min. D-1-8) Max Harz 1=208(LC 4) Max Uplift 1=101(1_C 4), 4=-153(LC 4), 5=-467(LC 4) Max Grav 1=237(LC 13), 4=237(LC 15), 5=312(LC 14) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. WEBS 2-5=-247/483 NOTES 1) Wind: ASCE 7-05; 150mph (3-second gust); TCDL=4.2psf; BCDL=3.0psf; h=18ft; Cal 11; Erp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 101 Ib uplift at joint 1, 153 lb uplift at joint 4 and 457 lb uplift aljoint 5. 7) This truss has been designed for a moving concentrated load of 200.O1b live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. "Semi including heels" Member end fixity model was used in the analysis and design of this truss. t�' 8) -rigid pitchbreaks ``�� LOAD CASE(S) Standard ,,`OPQ G•E•N �/���'�j' .•�\ SAC`'• N 68182 s OF Intl FL Cert. 6634 April 18,2011 � WARMRG -Verify dciyn pararnelnv and READ M07ES ON 7711S AND INCLUDED Iffl=REPERENCE PADS 1,0-7473 w. 20-'08 BEFORE USE. for MiTek This design is based only upon shown, and is for an individual building component. HT Design valid use only with connectors. parameters Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stabilityduring construction is the responsibillity of the MiTek' erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Bullding Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312. Alexandria, VA 22314. Tampa, FL 33610-4115 t PLATE LOCATION AND ORIENTATION 3/4 Center plate on joint unless x, y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and fully embed teeth. 0T/16. I For 4 x 2 orientation, locate plates 0-'Ad' from outside edge of truss. This symbol indicates the required direction of slots in connector plates. Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the plate 4 x 4 width measured perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING LOCATION Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate -Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths (Drawings not to scale) 1 2 3 TOP CHORDS ct-2 cza o WEBS C,4 q p i O u 3 ��� 3 O O �pb U U IL o- ~ C7-8 C6-7 CS-6 O H BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. PRODUCT CODE APPROVALS ICC-ES Reports: ESR-1311, ESR-1352, ER-5243, 9604B, 95-43, 96-31, 9667A NER-487, NER-561 95110, 84-32, 96-67, ER-3907, 9432A © 2006 MiTek® All Rights Reserved N81 MiTek' POWER To PERFORM.- MiTek Engineering Reference Sheet: Mll-7473 rev. 10208 General Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI. 2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative T, I, or Eliminator bracing should be considered. 3. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 4. Provide copies of this truss design to the building designer, erection supervisor, property owner and. all other interested parties. 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1. 7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1. 8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber. 10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements. 12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 13. Top chords must be sheathed or purlins provided at spacing indicated on design. 14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 15. Connections not shown are the responsibility of others. 16. Do not cut or alter truss member or plate without prior approval of an engineer. 17. Install and load vertically unless indicated otherwise. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. 19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient. 20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria. v Y. i i -# St. C l1dSr 025- PAUL WELCH INC. MECHANICAL ELECTRICAL CIVIL ENGINEERING 1 964 S.W. BILTMORE ST. SUITE#1 1 4 PORT SAINT LUCIE, FL 349B4 PHONE (772) 7B5 - 9BBB FAX (772) 7B5-9933 N ❑VEMBER 2B, 201 1 RE: RONNIE KLEIN 5B03 S. INDIAN RIVER DR. FORT PIERCE, FL To: MR. DAVE JOHNSON FF Culo COPY THIS LETTER IS WRITTEN IN RESPONSE TO YOUR NOVEMBER 4, 201 1 COMMENTS FOR OWNER TO MR. RONNIE KLEIN CONCERNING HIS REVISION REQUEST TO MASTER PERMIT 1 1 ❑5-❑252. COMMENT 1 - PER YOUR DISCUSSION WITH MR. KLEIN A SIGNED AND SEALED SURVEY WILL BE SUBMITTED WITH HIS NEW PERMIT APPLICATION DEPICTING THE LOCATION OF HIS PROPOSED NEW CARPORT SHOWING THE SIDE SETBACK ON THE PROPERTY. COMMENT 2 - ALL NEW OPENINGS FOR DOORS OR WINDOWS WILL HAVE A MINIMUM CONTINUOUS #4 BAR DRILLED AND SET IN EPDXY BETWEEN THE TIE BEAM AND FOOTER INSIDE AN S° X E3" COLUMN POURED ON EITHER SIDE OF THE NEW OPENINGS. COMMENT 3 - AS A CLARIFICATION ON (0-3) THE DETAILS ON THE PLAN VIEW SHOW THREE DIFFERENT SIZE FILLED CELL COLUMNS AS FOR THE PROPOSED CARPORT AS FOLLOWS. THE TWO COLUMNS NEXT TO THE HOUSE ARE B° X B" CONCRETE FILLED WITH ONE NO. 5 BAR. THE Two OUTSIDE CORNER COLUMNS ARE 1 6° X 1 6° X E3" CONCRETE FILLED WITH THREE NO. 5 BARS ONE IN EACH CELL. THE CENTER OUTSIDE COLUMN IS 1 6° X B" CONCRETE .FILLED WITH TWO NO. 5 BARS ONE IN EACH CELL. COMMENT 4 - PER YOUR :DISCUSSION WITH MR. KLEIN THE BATHROOM DESCRIBED IS A RENOVATION AND A NEW BATHROOM IS NOT BEING ADDED. HE CAN MAKE A DESCRIPTION CHANGE AS NEEDED. COMMENT 5 - PER YOU DISCUSSION WITH MR. KLEIN THIS IS NOT A NEW ELECTRICAL SERVICE. THE' ELECTRICAL SERVICE LOCATION SHOWN ON PAGE 3/9 WAS FOR INFORMATION AND SHOWS THE LOCATION OF HIS EXISTING SERVICE WHICH WAS CONSTRUCTED UNDER AN EARLIER PERMIT. HE IS MOVING THE LOCATION OF HIS EXISTING ELECTRICAL PANEL TO THE LOCATION SHOWN IN THE DRAWING. THANK YOU FOR Y❑UR ATTENTION TO THIS MATTER. SUBMITTED BY: PAUL WELCH INC. PAUL WELCH, P.E. REG. No 29945 PW:PP s .v ti LINE OF bum 11 GoyEFolill:TiT LOT 2 TAX PARCEL 3113-0001-000/8 ff L Jain a a I ", _" y ILA cor R&uox max TO EAST ROAD Row. = 6u74' DEED 681.c7 tEAS I S 89.48'55" E 1 t �► 648.48' S Pi 7 SMUT SET— S89.48'55"E 25.00' Lp ----------------------------------------- 684.9 CALC, 6927 MW NOIM W LOT 1-A OF J. F. WOM'S SUBONISION " S89.48'55"E - POINT ON LQIE N r` 1BIM SIM CONG to $,k � `�� WR ! i CONG PAD PC M.� WI1H COVER \WELL � \ 1 4t `\ TAX `f'i�K�.l `� :'y'-G(J02-000-1 628.58' o OUr-ME mar PIKICEL M \ 71.5'f i SET PODIT.ON UNE `3252� 8.4' WEST 5-3.6 3 S9 /7 IN. SETBACKREQ� M LEGAL DESCRIPTION: SURVEYORS NOTES , ABBREVIATIONS : FRONT 1. Unless otherwise noted on-y platted easements SET = Set 5/8" iron rebor with SIDES COMMENCING AT THE INTERSECTION OF THE NORTH LINE OF GOVERNMENT LOT 2. SECTION 1. TOWNSHIP 36 SOUTH. RANGE 40 EAST, WITH THE EAST are shown hereon. yeI low cap marked PSM.5543 CNRSIDES. RIGHT OF WAY LINE OF THE FLORIDA EAST COAST RAILWAY, RUN SOUTHEASTERLY ALONG SAID EAST 2. NO underground utilities c=r improvements were MEAS. Value as measured field 3 - RIGHT OF WAY LINE, A DISTANCE OF 1068.33 FEET TO THE POINT OF BEGINNING.- located unless otherwise �,hoWn. -,in - OH —OH —OH- Over Head Wires RFE1R I FROM SAID POINT OF BEGINNING RUN WITH A FORWARD ANGLE OF 69 DEGREES, 36 MINUTES AND 30 SECONDS TO THE EAST ALONG A LINE PARALLEL WITH THE NORTH 3. This site I i es within F I oc:d Insurance Rate Map X—X—X-= Chain Link Fence ZNG.'` LINE OF SAID GOVERNMENT LOT 2, A DISTANCE OF 692.7 FEET. MORE OR LESS TO Zone X. FO=Found 5/8" Iron Rebar THE EAST RIGHT OF WAY .LINE OF SOUTH INDIAN RIVER DRIVE, SAID RIGHT OF WAY LINE BEING 15 FEET EAST OF A CENTER LINE OF SOUTH INDIAN RIVER DRIVE 4. Flood Zone shown hereon is, an interpretation R.O.W. = Right of Way TECH. MEAS =Measured 5803 S . INDIAN MEASURED AT RIGHT ANGLES THERETO; THENCE WITH A BACK ANGLE OF 67 DEGREES AND 28 MINUTES, RUN NORTHWESTERLY ALONG SAID EAST RIGHT OF WAY LINE OF by the surveyor and is prdvided as a courtesy, . CONIC. = Concrete LAST FIELD DATE: 3/04/10 SOUTH INDIAN RIVER DRIVE, A DISTANCE OF 98.84 FEET; THENCE RUN WEST AND The f l OOd zone show I d ..be ver i f i ed by a C.P. = Concrete Pa A S B U I LT SURVEY PARALLEL TO THE NORTH LINE OF SAID GOVERNMENT LOT 2, A DISTANCE OF 688.74 determination agency.. ® = Wo t e r Me t e r FEET MORE OR LESS TO A POINT ON THE EAST RIGHT OF WAY OF THE FLORIDA EAST COAST RAILWAY; THENCE RUN SOUTHEASTERLY ALONG SAID EAST RIGHT OF WAY LINE 5. Bearings shown hereon ,are :based on the North ®= Power PoIe9OF FCe r t 1 f i ed t o: Ronnie S. Klein and Bri itte K. Klein THE FLORIDA EAST COAST RAILWAY. A DISTANCE OF 97.4 FEET TO THE POINT OF Iine of Subject Parcef as -being S89'48'55"E �= Bell South rryl J. Tompkins, P.A. BEGINNING; TOGETHER ALL LANDS LYING THE SOUTH LINE OF THEI OTEN according to deed calls. ®= We I 1 First American Title Insurance Company AFOREDESCRIBED TRTRAACTpTH AND THE NORTH LINE OF W S SUBDIVISION, ACCORDING Capital Cit Bank, Al1MA TO THE PLAT THEREOF RECORDED IN PLAT BOOK 1, AT PAGE 197 OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY. FLORIDA, AS WELL AS ALL LANDS ADJACENT TO AND SCALE: 1 "=60'Atlantic Land Des i g n s certifySAOA, I hereby certify that the survey shown hereon true and correct EASTERLY OF THE AFOREDESCRIBED LANDS TO THE MEAN HIGH WATER MARK OF THE INDIAN RIVER, EXCEPTING THEREFROM THE RIGHT OF WAY FOR PUBLIC ROAD AND the and is bests on actual m Technical StandardsMinimum of Chapter 61G17 DATE:3/05/10 UTILITY EASEMENTS, IF ANY, INCLUDING. HOWEVER, ALL RIPARIAN RIGHTS. 754 NE Jensen Beach Blvd. Jensen Beach, FL 34957 Florida administrative code. �`"` CPS AND '�, DRAWN: JC Ma i l i n Address: g gCIFIC o c� ArA THE NORTH FIFTY (50) FEET OF LOT 1—A OF J. F. WOOTEN'S SUBDIVISION, OF THE P.O. Box 1421 Jensen Beach, FL 34958 N. 5543 2010-0097 SOUTH 20 ACRES OF LOT 2. AND THE NORTH 33 ACRES OF LOT 3. IN SECTION 1. (772) 398-4290 ALD5543®gmai I .coin TOWNSHIP 36 SOUTH, RANGE 40 EAST, ACCORDING TO THE PLAT OF SAID SUBDIVISION DATE • REV 1 S I ONS RECORDED IN PLAT BOOK 1, PAGE 197, OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY. FLORIDA; EXCEPTING, HOWEVER, ALL RIGHTS OF WAY UPON AND ACROSS !. �� STITSOF FOR SAID LAND FOR PUBLIC ROAD AND RAILROAD PURPOSES. TM NOT VALID WITHOUT AWAUTHENTICATED ELECTRONIC SIGNATURE AND AUTHENTICATED ELECTRONIC SEAL I r PERrnjT = T14d Tc) f_4AIff'7 1# //GS=G;�f'- rtj R Z \ S89°4855E 8 ;Q R" 404T OF BEG11441�G FOUND f IRON PIPE SET 25.00'— — — — — — — — — — — c3` S, Q 25.W LEGAL DESCRIPTION: S 88002'4e E ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR CO ANCE REVIEWED BY DATE f f PLANS AND PERMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE TAX PARCEL 313-0001-000/8 1- - 655,59' FENCE CORDER . LIE 'e L* F* (TMUU sET POINT 04 u E \ \. ` c o `6 c 1 STORY C r' 05. BLOCK GARAGE 139e ---------------- 691,51' CALC. 692.7 DEED $oI NORTH W LOT 1-A OF J. F. WooTEN's SUBDIVISION COMMENCING AT THE INTERSECTION OF THE NORTH LINE OF GOVERNMENT LOT 2. SECTION 1. TOWNSHIP 36 SOUTH, RANGE 40 EAST, WITH THE EAST RIGHT OF WAY LINE OF THE FLORIDA EAST COAST RAILWAY. RUN SOUTHEASTERLY ALONG SAID EAST RIGHT OF WAY LINE, A DISTANCE OF 1068.33 FEET TO THE POINT OF BEGINNING; FROM SAID POINT OF BEGINNING RUN WITH A FORWARD ANGLE OF 69 DEGREES, 36 LINE OF SUTES AD GOVERNMD 30 ENT LOTDS TO THE EAST 2. A DISTANCEOF692E7 FEET.LEL MORETH THE OR LESS � TO THE EAST RIGHT OF WAY LINE OF SOUTH INDIAN RIVER DRIVE, SAID RIGHT OF WAY LINE BEING 15 FEET EAST OF A CENTER LINE .OF SOUTH INDIAN RIVER DRIVE MEASURED AT RIGHT ANGLES THERETO; THENCE WITH A BACK ANGLE OF 67 DEGREES AND 28 MINUTES, RUN NORTHWESTERLY ALONG SAID EAST RIGHT OF WAY LINE OF SOUTH INDIAN RIVER DRIVE, A DISTANCE OF 98.84 FEET; THENCE RUN WEST AND PARALLEL TO THE NORTH LINE OF SAID GOVERNMENT LOT 2, A DISTANCE OF 688.74 FEET MORE OR LESS TO A POINT ON THE EAST RIGHT OF WAY OF THE FLORIDA EAST COAST RAILWAY. THENCE RUN SOUTHEASTERLY ALONG SAID EAST RIGHT OF WAY LINE OF THE FLORIDA EAST COAST RAILWAY. A DISTANCE OF 97.4 FEET TO THE POINT OF BEGINNING; TOGETHER WITH ALL LANDS LYING BETWEEN THE SOUTH LINE OF THE AFOREDESC[BED TRACT AND THE NORTH LINE OF WOOTEN'S SUBDIVISION. ACCORDING TO THE PLAT'THEREOF RECORDED IN PLAT BOOK 1, AT PAGE 197 OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA; AS WELL AS ALL LANDS ADJACENT TO AND EASTERLY OF THE AFOREDESCRIBED LANDS TO THE MEAN HIGH WATER MARK OF THE INDIAN RIVES'. EXCEPTING THEREFROM THE RIGHT OF WAY FOR PUBLIC ROAD AND UUTvIDLITY EASEMENTS. IF ANY, INCLUDING. HOWEVER. ALL RIPARIAN RIGHTS, THE NORTH FIFTY (50) FEET OF LOT 1—A OF J. F. WOOTEN'S SUBDIVISION. OF THE SOUTH 20 ACRES OF LOT 2. AND THE NORTH 33 ACRES OF LOT 3. IN SECTION 1, TOWNSHIP 36 SOUTH, RANGE 40 EAST, ACCORDING TO THE PLAT OF SAID SUBDIVISION RECORDED IN PLAT BOOK 1. PAGE 197. OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA; EXCEPTING, HOWEVER, ALL RIGHTS OF WAY UPON AND ACROSS SAID LAND FOR PUBLIC ROAD AND RAILROAD PURPOSES. S88'02'4eE A� \ POWERPOLE . � • $. R c?Y�' ' *ELL •\ TAX PARCEL 702-0002-000/6 FIL M„ x •' L�Q .iJ.: . �?1 22416' J' e" i u" unc %= I 1 193,37' 635,51' CONC. DRIVE OUTSIDE SUBJECT PARCEL SUR EYORSNOTES] 1. Unless otherwise noted only platted easements are shown hereon. 2. No underground utilities or improvements Were located unless otherwise shown. 3. This site lies Within Flood Insurance Rate Map Zone X. 4. Flood Zone shown hereon is on interpretation by the surveyor and is provided as a courtesy. The flood zone should be verified by a determination agency. 5. Bearings shown hereon are based on the North line of Subject Parcel as being S89'48'55"E according to deed calls. , 3291' gt 74 t �t -A Oo � SET POINT U E 32,90 $4' NEST MIN. SE CWK REQ. FRONT— ` —I SIDES CNR SIDES — REAR 1� TECH. S. INDIAN RIVER DRIVE FIELD DATE:4/44/11 C.P.= Concrete Pa A S B U I LT S U R V E Y ®= Water Meter Certified to: Ronnie S. Klein and Brigitte K. Klein ® = PoWe r Pole ]Dam J. Tompkins, P.A. = Be I I South First American Title Insuronc Company ®= We I I Canital City Bank ISAOA ATRIA ABBREVIATIO S: SET = Set 5/8" iron rebar With yelloW cap marked "PSM 5543" MEAS.=Value as measured in field OH--OH--OH-= Over Head Mires X--X--X-= Chain Link Fence FD=F and 5/8" Iron Rebar R.O.I. = Right of flay MEAS. = Measured 5803 CONC. = Concrete LAST SCALE: 1"=60' At I antic Land Designs DATE:3/05/10 754 NE Jof the Treasure Coast ensen1peach Blvd. Jensen Beach, FL 34957 DRAM: JC Mailing Address: P.O. Box 1421 Jensen Beach, FL 34958 2010-0097 (772) 398-4290 ALD5543@Qmoil.com I DATE: I REVISIONS I I hereby certify that the survey sho*n hereon is true and correct and is based on actual measeuremenls taken in the field. This survey meets the Minimum Technical Standards of Chapter 61G17 Florida odministraliye code. IIM CPs, Digitally signed by C4�gIFICATAo James A. Cesiro Jr. James A: DN: cn=James A. Cesiro No. ssas pp o=Atlantic Land CeSI l O Designs of the TC,o , � STAT�101A�- Date. 2011.1T.21A14:34.03-OS'00' �D NOT VALID WITHOUT AN AUTHENTICATED ELECTRONIC SIGNATURE AND AUTHENTICATED ELECTRONIC SEAL c.-Vrr—rtoo .c,.r 1-47-1-3 p 1:1 / - 07-3 / G CA W S89048'55"E LEGAL DESCRIPTION: COMM1 NCING AT THE INTERSECTION OF THE NORTH. LINE OF GOVERNMENT LOT 2. SECTION 1. TOWNSHIP 36 SOUTH. RANGE 40 EAST. NTH' THE EAST RIGHT OF WAY LINE OF THE FLORIDA EST COST RAILWAY. RUN SOUTHEASTERLY ALONG SAID EAST RIGHT OF WAY LINE. A DISTANCE OF 1068.33 FEET TO THE POINT OF BEGINNING; MINUMTESAAND 30T OF BEGINNING TO THE EAST ALONG FORWARDTH A LINE PARALLEL WITHDEGREES. NORTH LINE OF SAID GOVERNMENT LOT 2. A DISTANCE OF 692.7 FEET. MORE OR LESS TO THE EAST RIGHT OF WAY LINE OF SOUTH INDIAN RIMER DRIVE. SAID RIGHT OF WAY LINE BEING 15 FEET EAST OF A CENTER LINE OF SOUTH INDIAN RIVER DRIVE MEASURED AT RIGHT ANGLES THERETO; THENCE WITH A BACK ANGLE OF 67 DEGREES AND 28 MINUTES. RUN NORTHWESTERLY ALONG SAID EST RIGHT OF WAY LINE OF SOUTH RIVER DIVE. AOF 98.84 FEET. THENCE RUN ST AND PARALLELDTON THE NORTH LINE OIFTDE SA GOVERNMENT LOT 2. A DISTANCE OF 688.74 FEET MORE OR LESS TO A POINT ON THE EAST RIGHT OF WAY OF THE FLORIDA EAST COST RAILWAY. THENCE RUN SOUTHEASTERLY ALONG SAID EST RIGHT OF WAY LINE OF THE FLORIDA EAST COAST RAILWAY. A DISTANCE OF 97.4 FEET TO THE POINT OF BEGINNING; TyGETHER WITH ALL LANDS LYING BETWEEN THE SOUTH LINE OF THE AFOREDESCRIBED TRACT AND THE NORTH LINE OF WOOTEN'S SUBDIVISION. ACCORDING TO THE PLAT THEREOF RECORDED IN PLAT BOOK 1. AT PAGE 197 OF THE PUBLIC RECORDS OF .ST. LUCIE COUNTY. FLORIDA. AS WELL AS ALL LANDS ADJACENT To AND EASTERLY OFk-THE AFOREDESCRIBED LANDS TO THE MEAN HIGH tl�►ATER IyIARK OF THE INDIAN RIVER EXCEPTING THEREFROM THE RIGHT OF WAY FOR PUBLIC ROAD AND UTILITY EASEMENTS. IF ANY. INCLUDING. HOWEVER. ALL RIPARIAN RIGHTS. THE NORTH FIFTY (50) FEET OF LOT 1—A OF J. F. WOOTEN'S SUBDIVISION, OF THE SOUTH 20 OF LOT 2. AND THESECTION 1. TOWNSHIP 6CRES SOUTH. RANGE 0 E ST. ACC ACCORDING TOETHE PLAT OF ISAID SUBDIVISION RECORDED IN PLAT BOOK 1. PAGE 197. OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY. FLORIDA; EXCEPTING. HOWEVER. ALL RIGHTS OF WAY UPON AND ACROSS SAID LAND FOR PUBLIC ROAD AND RAILROAD PURPOSES. TAX PARCEL 313-0001-000/8 TAX PARCEL 702-0002-000/6 SURVEYORS OTES: 1. Unless otherwise noted only platted easements are shown hereon. 2. No underground utilities or improvements Were located unless otherwise shown. 3. This site lies Within Flood Insurance Rate.Map Zone X. 4. Flood Zone shorn hereon is an interpretation by the surveyor and is provided as a courtesy. The flood zone should be verified by a determination agency. 5. Bearings shown hereon are based on the North line of Subject Parcel as being S89'48'55"E according to deed calls. ABBREVIATIONS: SET = Set 5/8" iron rebor With ello* cap marked "PSM 5543" LEAS.=Value as measured in field OH—=0H--0H—= Over Head Aires X—X—X—= Chain Link Fence FD=F and 5/8" Iron Reber R.O.W. = Right of *oy St W 4e Co, pate plov� MEAS. = Measured 5803 S.- INDIAN RIVER DRIVE - CONC. = Concrete LAST FIELD DATE:2/10/12 C.P.= Concrete Pa A S B U I L_ T S U R V E Y ® = Wa t e r Meter Cer t i f i ed to: Ronnie S. Klein and Brigitte K. Klein ® = PoWe r Pole Darryl J. Tompkins, P.A. = Bell South First American Title Insurance,Company ®= We I I Ca itol Cit Bank . ISAOA. ATIMA SCALE • 1 "=30' t a n I e Lan e s I g n s I hereby certify that the survey sho*n hereon is true and correct and is based on actual meoseurenents token -in the field. This 05 10 of the Treasure Coast survey meets the Minimum Technical Standards of Chapter 61G17 DATE.3 / / 754 NE Jensen Peach Blvd. Jensen Beach, FL 34957 Florida administrative code. It C. a DRAIN:. JC a i I i ng Address: Digitally signed by �QRttFt�ArA P.O. Box 1421 Jensen Beach, FL 34958 James A James A.CesiroJr. No.5543 2010-0097 (772) 398-4290 ALD5543@gmaii.com , r.:cn=James A.Cesiro Jc, o=Atlantic Land Cesiro'QesignsoftheTC.o DATE: REVISIONS. ema�vALD5543@g il.c 4 4 yl L U S O C C s= om;&US'."„ ._ SrABaP 11 1 11 ADD PROPOSED CAR PORT J r. :' Date:2012.&I'l tonlvP m or.46:16-os�001 S 2/10/12 FOR BOARD 11E I NOT VALID WITHOUT AN AUTHENTICATED ELECTRONIC SIGNATURE AND AUTHENTICATED ELECTRONIC SEAL NtoEy�rc 1-1"491 t7— ii CI.S - oz 9 7— Cp. tom., N $ E- N ,c S89'48'55"E LEGAL DESCRfPTION: COMMENCING AT THE INTERSECTION OF THE NORTH LINE OF GOVERNMENT LOT 2. SECTION 1. TOWNSHIP 36 SOUTH. RANGE 40 EAST. WITH THE EAST RIGHT OF WAY LINE OF THE FLORIDA EAST COAST RAILWAY; RUN SOUTHEASTERLY ALONG SAID EAST RIGHT OF WAY LINE. A DISTANCE OF 1068.33 FEET TO THE POINT OF BEGINNING; FROM SAID POINT OF BEGINNING RUN WITH A FORWARD ANGLE OF 69 DEGREES, 36 MINUTES AND 30 SECONDS TO THE EAST ALONG A LINE PARALLEL WITH THE NORTH LINE OF SAID GOVERNMENT LOT 2. A DISTANCE OF 692-7 FEET MORE OR LESS TO THE EAST RIGHT OF WAY LINE OF SOUTH INDIAN RIVER DRIVE SAID RIGHT OF WAY LINE BEING 15 FEET EAST OF A CENTER LINE OF SOUTH INDIAN RIVER DRIVE MEASURED AT RIGHT ANGLES THERETO; THENCE WITH A BACK ANGLE OF 67 DEGREES AND 28 MINUTES. RUN NORTHWESTERLY ALONG SAID EAST RIGHT OF WAY LINE OF SOUTH INDIAN RIVER DRIVE. A DISTANCE OF 98.84 FEET; THENCE RUN WEST AND PARALLEL TO THE NORTH LINE of SAID GOVERNMENT LOT 2. A DISTANCE OF 688.74 FEET MORE OR LESS TO A POINT ON THE EAST RIGHT OF WAY OF THE FLORIDA EAST COAST RAILWAY. THENCE RUN SOUTHEASTERLY ALONG SAID EAST RIGHT OF WAY LINE OF THE FLORIDA EAST COAST RAILWAY. A DISTANCE OF 97.4 FEET TO THE POINT OF BEGINNING; TOGETHER WITH ALL LANDS LYING BETWEEN THE SOUTH LINE of THE AFORED TO THE PLAT THEREOF RECORDED INO PLAT (BOOK 1. AT PAGE 197 IOF I THE PUBLIC ING RECORDS OF ST. LUCIE COUNTY. FLORIDA; AS WELL AS ALL LANDS ADJACENT TO AND EASTERLY OWTHE AFOREDESCRIBED LANDS To THE MEAN HIGH WATER MARK OF THE INDIAN RIVER EXCEPTING THEREFROM THE RIGHT OF WAY FOR PUBLIC ROAD AND UTILITY EASEWNTS. IF ANY, INCLUDING. HOWEVER, ALL RIPARIAN RIGHTS. THE NORTH FIFTH' (50) FEET OF LOT 1—A OF J. F. WOOTEN'S SUBDIVISION. OF THE SOUTH 20 ACRES OF LOT 2. D THE NORTH 3.3TOWNSHIP 36 SOUTH. RANGE 0 EAST. ACCORDING TOETHEFPLAT OF LOT 3.(SAID SUBSEIODIVISION RECORDED IN PLAT BOOK 1. PAGE 197. OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY. FLORIDA; EXCEPTING, HOWEVER, ALL RIGHTS OF WAY UPON AND ACROSS SAID LAND FOR PUBLIC ROAD AND RAILROAD PURPOSES. TAX PARCEL 313-0001-000/8 7i12-0002-000/6 SUR EYORS OTES: 1. Unless otherwise noted only Matted easements are shown hereon. 2. No underground utilities or improvements Were located unless otherwise shown. 3. This site lies Within Flood Insurance Rate.Map Zone X. 4. Flood Zone shown hereon is an interpretation by the surveyor and is provided as a courtesy. The flood zone should be verified by a determination agency. 5. Bearings shown hereon are based on the North line of Subject Parcel as being S89'48'55"E according to deed calls. SCALE:1 "=30' At DATE:3/05/10 764 NE DRAWMe JC ABBREV I AT I ONyS : SET = Set 5/8" iron rebar with yellow cap marked "PSM 5643" MEAS.=Value as measured in field OH —OH —OH-= Over Head Wires X—X—X-= Chain Link Fence FD=F and 5/8" Iron Rebor R.O. �y. = Right of Way MEAS. = Measured 5803 CONC. = Concrete LAST C.P.= Concrete Pa A S B U ®= Vlater Meter St. c Co. F, Date 1 nit proved S.' INDIAN RIVER DRIVE FIELD DATE:2/10/12 1 L T SURVEY ®= Polder Pole Certified to: Ronnie S. K. = Bell South Darryl J. Tompkins, P.A. First American Title Insuran ®_ dye I I Capital City Bank, ISAOA, A IantIC Land Ueslgns of the Treasure Coast Jensen each Blvd. Jensen Beach, FL 349: ailing Address: P.O. Box 1421 Jensen Beach, FL 34958 2010-0097 (772) 398-4290 ALD5543@qmoii.com DATE: I REVISIONS --1 and Company I hereby certify that the survey sho*n hereon -is true -and correct and is based on actual meoseurements taken in the field. This survey meets the Vinimum Technical Standards of Chapter 61G17 Florido odninistrative code. �tNc c8s� Digitallysigned by GygTIFIC,��A James A James&Cesiroh x0.55as V: DN: cn=lames A Cesiro ^Jr.,o=Atlantic land Cesiro e DesignsoftheTC,oy Jr. q - ;- Date- 2012.1)2.11 jOtoRt9P ? .z' 07:46:16-05'00' S b NOT VALID WITHOUT AN AUTHENTICATED ELECTRONIC SIGNATURE AND AUTHENTICATED ELECTRONIC SEAL <J Go S t9 N� S89'48'55"E Q TAX PARCEL 313-0001-000/8 FILE. co S 88'02'4V E 1 . _ • —� a s FENCE =:r 655,59' SET POINT LIE \ — —.—.—, ft SET \ Co j 224.26' 04 1 STORY CONC\ BLOCK GARAGE 13 o" $" POINT OF BEGINNING"-"' FOUND Y IRON PIPE SET ----------------- Q� \ PR <' •6� �JC ems► 25.00 ------------- _ _ VLL \ _ CP 691.51' CALL 692.7 DEED _ — — - — — — — 4- — — Al — 212 NORTH 50' LOT 1-A OF J. F. WOOTEN'S SUBDryIS10NLO `\ •� �• \ •���. N MolMalr 2560' SET U \ M S88*02'45"E 193.3T 635.51' SET POINT 3� CONC. DRNE OUTSIDE SUBJECT PARCEL 64' PEST TAX PARCEL 702-0002-000/6 LEGAL DESCRIPTION: COMMENCING AT THE INTERSECTION OF THE NORTH LINE OF GOVERNMENT LOT 2. SECTION 1. TOWNSHIP 36 SOUTH. RANGE 40 EAST, WITH THE EAST RIGHT OF WAY LINE OF THE FLORIDA EAST COAST RAILWAY. RUN SOUTHEASTERLY ALONG SAID EAST RIGHT OF WAY LINE, A DISTANCE OF 1068.33 FEET To THE POINT OF BEGINNING; FROM SAID POINT OF BEGINNING RUN WITH A FORWARD ANGLE OF 69 DEGREES, 36 MINUTES AND 30 SECONDS TO THE EAST ALONG A LINE PARALLEL WITH THE NORTH LINE OF SAID GOVERNMENT LOT 2, A DISTANCE OF 692.7 FEET. MORE OR LESS TO THE EAST RIGHT OF WAY LINE OF SOUTH INDIAN RIVER DRIVE. SAID RIGHT OF WAY LINE BEING 15 FEET EAST OF A CENTER LINE OF SOUTH INDIAN RIVER DRIVE MEASURED AT RIGHT ANGLES THERETO; THENCE WITH A BACK ANGLE OF 67 DEGREES AND 28 MINUTES, RUN NORTHWESTERLY ALONG SAID EAST RIGHT OF WAY LINE OF SOUTH INDIAN RIVER DRIVE. A DISTANCE OF 98.84 FEET; THENCE RUN WEST AND PARALLEL TO THE NORTH LINE OF SAID GOVERNMENT LOT 2, A DISTANCE OF 688.74 FEET MORE OR LESS TO A POINT ON THE EAST RIGHT OF WAY OF THE FLORIDA EAST COAST RAILWAY; THENCE RUN SOUTHEASTERLY ALONG SAID EAST RIGHT OF WAY LINE OF THE FLORIDA EAST COAST RAILWAY, A DISTANCE OF 97.4 FEET TO THE POINT OF BEGINNING; TOGETHER WITH ALL LANDS LYING BETWEEN .THE SOUTH LINE OF THE AFOREDESCRIBED TRACT AND THE NORTH LINE OF WOOTEN'S SUBDIVISION. ACCORDING TO THE PLAT THEREOF RECORDED IN PLAT BOOK 1, AT PAGE 197 OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY. FLORIDA; AS WELL AS ALL LANDS ADJACENT TO AND EASTERLY OF THE AFOREDESCRIBED LANDS TO THE MEAN HIGH WATER MARK OF THE INDIAN RIVER. EXCEPTING THEREFROM THE RIGHT OF WAY FOR PUBLIC ROAD AND UANDLITY EASEMENTS. IF ANY, INCLUDING, HOWEVER, ALL RIPARIAN RIGHTS, THE NORTH FIFTY (50) FEET OF LOT 1-A OF J. F. WOOTEN'S SUBDIVISION. OF THE SOUTH 20 ACRES OF LOT 2, AND THE NORTH 33 ACRES OF LOT 3. IN SECTION 1, TOWNSHIP 36 SOUTH, RANGE 40 EAST. ACCORDING TO THE PLAT OF SAID SUBDIVISION RECORDED IN PLAT BOOK 1, PAGE 197, OF THE PUBLIC RECORDS OF ST. LUCIE' COUNTY. FLORIDA; EXCEPTING, HOWEVER, ALL RIGHTS OF WAY UPON AND ACROSS SAID LAND FOR PUBLIC ROAD AND RAILROAD PURPOSES. SUR EYORS OTES: 1. Unless otherwise noted only platted easements ore shown hereon. 2. No underground utilities or improvements Were located unless otherwise shown. 3. This site lies Within Flood Insurance Rate Map Zone X. 4. Flood Zone shorn hereon is an interpretation by the -surveyor and is provided as a courtesy. The flood zone should be' verified by a determination agency. 5. Bearings shown hereon are based on -the North line of Subject Parcel as being S89'48'55"E according to deed calls. 11/- D St LUCIE COUNTY BUILDING DIVISION REVIEWED , FOR COM 1 CE REVIEWED BY DATE 44, PLANS AND PERMIT MUST BE KEPT ON JOD OR NO INSPECTION WILL ME MADE ABBREVIATIO S: SET = Set 5/8" iron rebor With elloW cap marked "PSM 5543" yMEAS.=Value as measured in field OH-- OH- -OH-= Over Head Aires X--X--X-= Chain Link Fence FD=F and 5/8" Iron Rebor R.0.�1.-= Right of }play 5803 MEAS. Measured CONC. = Concrete LAST C.P.= Concrete Pa A S B U ®= dater Meter O. 6 V cri MIN. SETBACK REQ. FRONTSIDES 10 MR SIDES:2—D — REAR TECH. S. INDIAN RIVER DRIVE FIELD DATE:4/44/11 I LT SURVEY ®= PoWer Pole Cert i I ied to: Ronnie S. Klein and Brigitte K. Klein ® Bell I South Darryl J. Tompkins, P.A. = First American Title Insuranc Company ®_ }flJe I I Ca itol Cit Bonk, ISAOA, ATRIA 5CALE • 1 "=60'Atlantic LandDesigns I hereby certify that the survey sho*n hereon is true and correct and is based on actual measeuremenis taken in the field. This 05 10 of the Treasure Coast survey meets the Minimum Technical Standards of Chapter 61G17 DATE: 3 / / 754 NE Jensen peach Blvd. Jensen Beach, FL 34957 Florida administrative code. 11 Cea DRAWN: JC Moiling Address: A"�:'' Digitally signed by CQggIFI CAl,B P.O. BOX 1421 Jensen Beoch, FL 34968 James /::James=James A. A. No. 5543 l:: DN: cn=James A. Cesiro 2010-0097 (772) 398-4290 ALD5543@gmail.com '<%:..Jr.,o=Atlantic Land DATE' REVISIONS Cesiro Ue5ign5oftheTC,o , il.-AI,p5543@g ail. 4/14/11 REVISE SIDE LOT LINES TO REFLECT CORRECT ALIGNVENT STATE OF 4 2 D PROPOSED CAR PORT J r. Date: 2011.1'T.21 ALOR 10� 1434:03 -05'00' s� NOT VALID WITHOUT AN AUTHENTICATED ELECTRONIC SIGNATURE