Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSf A. Date: �3N-1!�J Fee Due: I-ReceiDIW'- '' - t ` I< < >?ermit # DO Planning & Development Services Building & Code Regulations Division 2300 Virginia Ave. Fort Pierce, FL 34982 (772)462-1553 HazaTL r)s 1 0 � Lt3 SPECIALTY PERMIT APPLICATION ❑ Electrical El Plumbing ❑ HVAC ❑ Fence SCq ❑ Shed ❑ Demolition ❑ Gas ❑ Siding St SyN�o See page 2 for instructions and additional paperwork required for specialty permits COVnty 1. Location/Site Address: 2300 N 51ST STREET 2. Parcel ID Number: 1431-701-0186-000-6 Office Use Only �M�LWA� EMM& MEAM (MANE IJ2l1 3. Complete Description of Project or Work: INSTALLATION OF SOLAR WATER HEATER 4. Owners In�Ipl�ti�%)PO Name: ALBERT GEORGE 5. Contractors Information Address: 2300 N 51 STREET City: FT PIERCE Zip: 34950 State: FL Phone: 772-519-6632 6. Value of Construction: $ 2000.00 FL Reg/Cert #: GV G 5(o Aa County Cert#: Business Name: TRADEWIND SOLAR Phone: 7724644630 FaX: 7723986131 OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in , I compliance with all applicable laws regulating con d zon' PRINT OWNER OR CONTRACTOR NAME SIGNATURE OF OWNER OR CONTRACTOR STATE OF FLORIDA, COUNTY OF ST ( i ACKNOWLEDGED BEFORE ME THIS DAY OA 20 1 BY WHO IS PERSONALLY KNOWN TO ME OR WHO HAS IPRDUCED k,UkENTIFICATION. -- — - JEAN M. KELLY 00 1 OF NOTARY TYPE OR PRINT NAME OF NOTARY MY CO�SION # DD684633 �o„d�� EXPIRES June 12, 2011 ION NUMBER (407) 3�J8-0i ;2. — - FlnridaNetarvS111VIM COZ OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. EXEMPT: A/C -HEAT REPLACEMENT WITH CONTRACT UNDER $7500.00 FLORIDA SOLAR ENERGY CENTER% Approved Solar Energy System Approval Date: Jun 2011 FSEC 4 S00171E DISTRIBUTOR SYSTEM Solene Solene/Aurora 80PV 950 Sunshine Lane Altamonte Springs, Florida 32714 This system was evaluated by the Florida Solar Energy Center (FSEC) in accordance with the Florida Standards Program for Solar Domestic Water and Pool Heating Systems (FSEC Standard 10"5) and was found to meet the minimum standards established by FSEC. North Central South The calculated Florida Energy Factors for this system are: 12.0 15.4 15.4 DESCRIPTION Collector Manufacturer Model Number Units Total Rating (Btu) I Solene Solene/Aurora SLAR-40 2 75,800 _ 2. 3. 4. F-k1PkkAPM~ Tank Manufacturer Model Number aw I 1. Lochinvar FTA-120K 120 2. Rheem 81RV120-1 120 3. AO Smith Sun 120 120 4. Any Equivalent UL Listed Tank 120 Manufacturer Model Number Power Draw (Watts) Rated Power _Pump 1. El Sid SID10PV 5 1/100 H.P. 2. March 809BR-24VDC 15 1/100 H.P. 3. Laing D5 09 0B 10 1/100 H.P. 4. Controller Manufacturer Model Number Type: Photovoltaic 1. Sunflre AE-10ST 2. Kyocera KS-10 3. Power Up BSP-10-12 Freeze Protection l . Freeze prevention valve 2. Manual drain down Other Major Components 1. 2. 1679 CLF,wi:��e 1tu, , G�nti�. Fu�wn:� 32922-5103 - TEL.121-638. 1000 - FAx 321-638-1010. O'w%v-f9Cc-ucfcthi U%&AV m SVM?A OF FDOWA - Av Eouv Ac?C4 RnOM , A ►?ESM" LNSDnM OF THS l baAZ" OF CEWPA FLOCbDA FSEC # S00171 A FLORIDA SOLAR ENERGY CENTER' Approved Solar Energy System Approval Date: Jun 2011 PV MODULE 91 P $DIor Tu1c ST. LUCIE ^JUNTY BUDDING DIVISION REVIEWED FOR COMP�lCE REVIEWED BY V DATE D PE MIT PLAN MUST BE KEPT ON JOB OR NO INSPECTION WILL $E MADE 1679 CLE:VI].AKE Ro,,.n. (.LxV,\. Ftc)Rlr):\ 32922.5703 • TEL 321-638-1000 • F,v 321-638.1010 • wwcv.t .nct:cchr UxrvEryry S,6wr.i or Ftor-cK • AY ErxyL 0--"0 Y/Arr9rrlATrVE &-n0N EPtortR • A RESFACCH L%TrNrE or THE UNWERS Y CIF CENYwL ftaxA Property Appraiser - St.Lucie Countv, FL Page 1 of 1 PROPERTY RECORD CARD Albert George Jr Record: 1 of 1 <<Prev Next >> Spec.Assmnt Taxes Exemptions Permits Home Print Property Identification CIECpG2 Site Address: 2300 N 51st St ParcellD 1431-701-0186-000-6 Sec/Town/Range: 31 :34S :40E Account #: 10503 �� < Map ID: 14/31S Land Use: SF Res Zoning: RS-4 City/Cnty: St Lucie County Ownership and Mailing Legal Description Owner: Albert George Jr Melinda George HARMONY HEIGHTS ADDN BLK K LOTS 17 AND 18 (OR 1316-632) Address: 2300 N 51st St Fort Pierce FL 34947 Sales Information Assessment 2010 Final Total Land and Building Date Price Code Deed Book/Page 2010 Final: 70800 Land Value: 15000 Acres: 0.5 7/17/2000 69900 00 WD 1316 / 0632 Assessed: 63842 Building Value: 55800 1/1/1900 0 / Ag.Credit: 0 Finished Area: 1728 SgFt Exempt: 38842 Taxable: 25000 Taxes: 632.79 BUILDING INFORMATION I' a.. cb� . z - - Exterior Features View: RoofCover: FS - Fibrglss Shg RoofStruct: GA - Gable ExtType: HC- - HC- YearBlt: 1947 Frame: Grade: C- - C- EffYrBlt: 1976 PrimeWall: FS - Frm Stucco StoryHght: 0010 - 1 Story No.Units: 1 SecWall: Interior Features BedRooms: 3 Electric: MX - MAXIMUM PrmintWall: WP - Plaster FullBath: 2 HeatType: FHA - FrcdHotAir AvgHt/FI: 1/213ath: 0 HeatFuel: ELEC - Electric Prm.Flors: CU - Carpet %A/C: 100 %Heated: 100 %Sprinkled: 0 Special Features and Yard Items Land Information Type Y/S Qty Units Qual. Cond. YrBlt. No. Land Use Type Measure Depth DWC - Driv-Concret Y 1 500 AV AV 1976 1 0100-SF Res 210 -Front Ft 122.5 179 FNW6 - WOOD FEN 6' Y 1 155 AV AV 1999 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED. http://www.paslc.org/prc.asp?prcIid=143170101860006 5/31/2011 .. w U SOLENE MOUNTING COLLECTORS SHALL u BRACKET W/ LAG BOLT SOLENE BRAND NOT BE INSTALLED IN "CORNER 3"X3"X)f;" THK 3" L 6063T6 J AS SHOWN BELOW COLLECTOR ZONES" AS SHOWN ON DIAGRAM ALUM SQRTB WITH 1 "DXK6" O oe = THK 2-Y4 L ALUM TUBE SOLENE MOUNTING BRACKFT INSERT BOTH ANODIZED C 0 u W/ LAG BOLT AS Q SHOWN BELOW z .S. SOLENE BRAND a Qz0 0 �'� COLLECTORS z ccoo N d d N X o w RIDGE Li i m w � Z SOLENE BRAND 0W 8 MOUNT STAND OFF- AS co � QIt o _ � �\ -3 SCALE: NTS w o Z HIP ROOF END > (4« n c 3 CONDITION Z L. 0 =SOLENE ROOF ZONE 3 LONG DIMENSION SOLENE a a W z COLLECTOR CORNERS GABEL END ROOF MOUNTING D O � lIO S -O3 76 ACKET COLLECTOR o HIP ROOF GENERAL CONDITION O � CONDITION ROOF CONER ZONE SHALL BE 10 PERCENT = w OF SHORT DIMENSION OF BUILDING, OR 40 z , PLAN O F COLLECTORS PERCENT OF MEAN ROOF HEIGHT, OR 7 FT — WHICH EVER IS SMALLER. E Co o} L-3 SCALE: 3/16"=1'-0" 2 R 0 0 F LAYOUT PLAN F SHEATHING O > GENERAL NOTES: L-3 SCALE: NONE FIL a z 1. COLLECTOR CONNECTIONS SHOWN HAVE BEEN DESIGNED TO RESIST WIND LOADS OUTLINED IN THE 2007 FLORIDA BUILDING CODE, AND 2009 w SUPPLEMENT, CHAPTER 16 FOR 146 MPH EXPOSURE "C" WIND VELOCITY AND PER ASCE 7-05, CHAPTER 6.0 FOR 146 MPH EXPOSURE "C" WIND Q O h VELOCITY TYPICALLY. 2x PT OR UNISTRUT CONTINUOUS ALONG o O 2. LAG BOLT CAPACITIES AND EMBEDMENTS ARE BASED UPON "NATIONAL DESIGN SPECIFICATION FOR STRESS GRADE LUMBER AND FASTENINGS" AS PANEL FOR MOUNTING m PUBLISHED BY THE NATIONAL FOREST PRODUCTS ASSOCIATION. APPLY ROOF GRADE SEALANT TO ALL CONTACT SURFACES. W/ 3/8" ST STL ALL—THRD ROD W/ NUT WOOD TRUSS r & WASHER EA END — PROVIDE "LOCTITE" SYSTEM #2 SYP71 O z 3. ALL CONNECTIONS ARE FOR ROOFS 0' TO 45' MAX SLOPE CONDITIONS. ALL CONNECTORS ARE FOR MEAN ROOF HEIGHTS NOT TO EXCEED 30'-0". AT ALL NUTS. CENTER RODS ® 3'-0" o/c SY BETTER E' MAX SPACING 14 Q z 4. WIND TUNNEL TEST DATA FOR THESE CONNECTIONS AND ASSEMBLIES HAS BEEN COMPILED BY TEXAS A&M UNIVERSITY, COLLEGE STATION, Tx. AND IS MISSED TRUSS SOLENE N O AVAILABLE THROUGH HELIOCOL, INC. WIND LOAD CALCULATIONS ARE AVAILABLE THROUGH HELIOCOL, INC. REPORT SL-3. ui ,u 5. ALTERNATIVELY SOLENE MOUNTING BRACKET CAN BE FASTENED TO THE SOLENE COLLECTOR WITH EITHER (1) STSTL BOLT AND NUT, OR (2) Y4" W z o SELF TAPPING SHEET METAL SCREWS. 7 BRAND SPANNER INSTALL Wd z > L-3 SCALE: NTS w SOLENE MOUNTING w SOLENE SOLENE BRACKET AND STAND SOLENE MOUNTING C� 0 N MOUNTING WOOD TRUSS BRACKET AND STAND jjC�y MOUNTING OFF ASSY OFF ASSY z z BRACKET ROOF BRACKET FLAT SOLENE BRAND SYSTEM #2 SYP SOLENE BRAND Q ROOF SOLENE BRAND SHEATHING CONCRETE COLLECTOR OR BETTER COLLECTOR Q w SHEATHING COLLECTOR g 0 ) SOLENE BRAND TILES w o O COLLECTOR BARREL Q �U� z N Q TILES. Lu In O 3., WOOD M TRUSS2 SYP REC111309 �.. OR BETTER 'SCAL' NOTED 3 0 0 3" 3" ROOF O U O >� SHEATHING J o 4X LOCATE BEWI TH TWEEN ROOF Q z z TRUSSES AND NAIL SEE NOTE 3 SHEATHING o W z NAILS AT EACH END" DIA STAINLESS" DIA STAINLESS U ? O " STL LAG BOLTS AT EACH STL LAG BOLTS AT EACH �6" DIA STAINLES NOTE: CUT OUT OR REMOVE X DIA S NLESS NOTE: CUT OUT OR REMOVE Z z NOTE: ROOF FINISH STL LAG BOLTS AT EACH SOLENE BRAND CoNN 7YP. WOOD TRUSS TILE TO INSTALL STANDOFF c� Z SOLENE BRAND CONN TYP. TILE TO INSTALL STANDOFF a z W SYSTEM 2 SYP ASSY. THEN REINSTALL TILES STL LAG BOLTS AT EACH aj U OMITTED FOR CLARITY SOLENE BRAND CONN TYP. NOTE: ROOF FINISH # ASSY. THEN REINSTALL TILES SOLENE BRAND CONN � w w o OMITTED FOR CLARITY OR BETTER AROUND MOUNTING AROUND MOUNTING ��Q MISSED TRUSS SOLENE SHINGLE/METAL HARDWARETYP ' HARDWARE w�� 3 BRAND NAILER INST.5 FLAT CONC. TILE ROOFDRAWING NO. UZ L-3 "_ . "(&BUILT UP ROOF (&BARREL TILE ROOF T o,Z 0 SCALE: 1-1/2 -1 -0 SCALE: 1-1/2"=1'-0" L-3 SCALE: 1-1/2"=1'-0" SCALE: 1-1/2"=1'-O" QL—� 8 Q SHEET 1 OF 1