Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSDAT.: FEES Planning & Development Services Department Building & Code Regulation Division $C _ 2300 Virginia Avenue B�' Yti) Ft. Pierce, FL 34982-.5652 Tel. 772-462-1553 St Lucie r, APPLICATION FOR ROOF PERMIT Ounty SEE REVERSE SIDE FOR INSTRUCTIONS 1. Location/Site Address: 3CC5 NF.T T LDS a3�V D 2. Parcel ID Number: 950a- 51 - C:)5-1► —OCX� - H Office Use Only Section Toweship Range I Map P e Zo in !,!Ad Use Initials ' `r 3. Description of Project or Work Activity: 0 F - 7_q_P�ROF F + 1��� LPr CE 4. Total Roof Area (square feet): � k 1� 5. Roof Pitch: 3 11 ;f 6. Type of Roof: [ ] Fiberglass Shingle [ ] Concrete Roof Tile [ ] Tar & Gravel [ ] Modified Bitumen [ ] Wood Shake / Shingle [\d Other ME TArL. JA Product Approval required for all types of Roofing Material (2 Sets) ] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product Approval attached ** Roof Mitigation per F.S. 553.844 will be required. 7. Owner Information 8. Contractor Information Name: "UywPk2n * R1 U50N Address: [ -"l S'S S•.k3 5-s' ANa _tLtS_D(2 City: _?PcLM CITIA State: FL. Zip: 3\- qcP Phone: 71a.8314.9131 9. Value of Construction: $ Lk(6_T5.o0 FL Reg/Cert #: C.c.c.- 02a l A i County Cert #: I Business Name: S-CUpRT RooF INC, Cell Phone: "Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval. CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be ��done in compliance with l�ica� a laws regulating construction and zoning. %`0 "V� ` ,/ 7ZA PRINT QUALIFIERS/OWNERS NAME SI URE OF QUALIFIER/OWNER STATE OF FLORIDA, COUNTY OF M Qrlti (\ ACKNOWLEDGED BEFORE ME THIS '2,? DAY OF Ivl G.\,.1 20_LL BY VO:\VL. 0 W O S PERSONA L O N TO ME OR HAS PRODUCED 11 AS IDENTIFICATION DANINE FRANTA:75&3U4OW9 I ATURE OF NOTARY TYPE OR PRINT NAME OF NOTARY 1• °seal�) �� �� 3 .; .� MY COMMISSION a DCOMMISSION NUMBER 40 '?: a.= EXPIRES; February Bonded Thru Notary Public NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEM TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Revised 4/26/2010 B ■ & ■ B ■ 706 South ". Street 4950 Engineering Consultants Inc. T Pierce, 7 37785 9 9 Tel. (772) 708 7785 omvermudez@hotmaii.com FINAL INSPECTION (WIIHSIRUCIURAI.CIIUWATMAF11 RTHEFACT) May 6, 2013 For: H. R. Warren Resident at, 385 Nettles Blvd. Jensen Beach FL 33469 TO: St. Lucie County Building Department Client: Stuart Roofing, 140 NE Dixie Hwy, Stuart, Fl 34994 (� / Permit: No. 1106-0009 ❑ Installation of a 26Ga. 5V metal mill finish Roof after the fact. To Whom It May Concern: On May 3, 2013 B & B Engineering Inc. was requested by Stuart Roofing, a Licensed Roofing Contractor to certify the proper re nailing, TU plus over 5/8" sheathing underlayment and 5-V Crimp Metal Re -Roof installation Systems for the above project. Certification: B & B Engineering Inc Certify that the above re nailing, dry -in TU plus underlayment and 5-V Crimp new roof cover appeared have been properly installed, according to the 2007 F.B.C., St. Lucie County Building Department Code, the Manufactures' recommendations and Miami -Dade County NOA approvals. To meet the required wind loading as per ASCE 7-05, the existing plywood shearing was re - nailed to the existing roof structure using galvanized steel 8-D ring shank nails at 4" on center edge and 6" center field. The TU plus peal and stick base underlayment for the roof appeared was properly installed to the roof structure. To the best of our knowledge and professional ability, it is B & B Engineering Inc. opinion that the work was properly done. Limitations. Our professional services have been performed, our finding obtained and our opinions prepared in accordance with general accepted structural engineering principles and practices. This Company is not responsible for the conclusions, opinions or recommendations made by others based on our findings. The scope of the inspection was intended to evaluate the new re -roof system installation and to assure its integrity. The opinions submitted in this report are based upon the field inspection performed on May 04, 2013. Approv , Oscar M. Bermudez, PE - /3 Fl. License No. 55141 PLANNING AND DEVELOPMENT SERVICES DEPARTMENT Building and Code Regulations Division 2300 VIRGINIA AVE. FORT PIERCE, FL 34982 (772)462-1553 PERMIT RENEWAL REQUEST ADDRESS: �S 4 P;r IeS AlvJ ,°nsPh fkh, PERMIT NUMBER: ( I ntoo — 000 9 I, TDh -71)raer , AM REQUESTING THAT THE ABOVE PERMIT IS RENEWED FOR A MONTHS. I UNDERSTAND THAT I MUST SCHEDULE AND PASS ALL REQUIRED INSPECTIONS FOR THE PERMIT TO BE FINALED. FURTHER, I UNDERSTAND THAT THIS IS A ONE TIME RENEWAL AND THE PERMIT SHALL EXPIRE SHOULD I NOT RECEIVE A PASSING INSPECTION DURING ANY SIX MONTHS PERIOD DURING THE RENEWAL PERIOD. OR CONTRACTOR SIGNATURE STATE OF FLORIDA, County of 5-k TE ACKNOWLEDGED BEFORE ME THIS 'I ' " DAY OF M V" I , 20 1 .3 BY `k, H o 1J —Ty �?W" WHO IS PERSONALLY KNOWN TO ME , OR HAS PROVIDED AS IDENTIFICATION. STATE F RIDA, ounty of -vk e--T 1 1-) SEAL SIGN TUREOFNOTARY COMMISSION NUMBER FOR OFFICE USE ONLY: RENEWAL FEE: $ No. of Open Inspections _ Total No. of Inspections Original Permit Fee $ x Open Inspections (%) = $. TANYA TURNER Commission # EE 133479 Expires September 26 2015 B°nded Thru Aoy Fain Inquy� �-38S70f9 (% of Open Inspections). Example: [15 _ 23 = .65(%)] $175.00(permit fee) x .65(%) = $113.75 (Renewal Fee) SLCPDSD REV 4/11/2011 (Renewal Fee). JOSEPH E. SMITH, CLERK OF THE CIRCUIT COURT - SAINT LUCIE COUNTY FILE # 3596851 OR BC 3297 PAGE 1875, Recorded 06/01/2011 09:33 AM PERMir MIMBPR NOTICE OF CONDMNCEMENT The undersigned hereby given notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida statutes the following information is provided in the Notice of commencement. 1. DESCRIPTION OF PRO 9PERTY (Legal description and street address) TAX FOLIO NUMBER: 450r1-501- OS ►1 -�jm _y SUBDWWON� s '. BLOCK TRACE LOT BLDG UNIT 2. GENERAL DESCRIPTION OF IMPROVEMENT: R4.Roo1= 3. OWNER INFORMATION: a. Name W A'RRgJJ . "QW ARC -► okt_�\SZ N b.Address 1-e SS SuJ S1 ANDkz,pWc::- '17R _PWn CkN F�.,W,!aproperty d. Name and address of fee simple titleholder (if other than owner) 4. CONTRACTOR'S NAME, ADDRESS AND PHONE NUMBER: S�UAR C R ODF 1 N G l,a. Ctl3'Ji.Q$S{ 5. SURETY'S NAME, ADDRESS AND PHONE NUMBER AND BOND AMOUNT: 6. LENDER'S NAME, ADDRESS AND PHONE NUMBER: 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13 (1xa) 7., Florida Statutes: NAME, ADDRESS AND PHONE NUMBER: 8. In addition to himself or herself, Owner designates the following to receive a copy of the Lienor's Notice as provided in Section 713.13 (1)(b), Florida Statutes: NAME, ADDRESS AND PHONE NUMBER: 9. Expiration date of notice of commencement (the expiration date is I year from the date of recording unless a different date is specified) _, 20-. Signatmae of Owner or Print Name and Provide Signatory's Title/Office Owner's Authorized ORicer/Director/Partner/Manager State of Florida County of 3t . WC-1e The foregoing instrument was acknowledged before me this 2 Aw day of V_Afk -( 20 1 t By EACK.- O.VLV W91e9_QJ as oWIJ2Q. (Name of person) (Type of authority... e.g. Owner, officer, trustee, attorney in fact) For (Name of patty on behalf of whom instrument was a led) y known_ or produced the folbwing type of !D: ,�ti'�n"riiyb�, TANYATURNER — *YAO, 1` Je Z Cartirtkissian DD 692349 (Printed Name of N Public) ( ignature of No Public) '� ltrly 5, 2011 Notary �Y ., sa.wm.�r�o;rt,nvr�.soo-xsrors Under penalties of perjury, I declare that I have read the foregoing and that the facts in it are true to the best of my knowledge and belief (section 92,525, Florida Statutes). Signature(a) of Owner(s) oor/r'' r(s)'Autborized Officer/Director/Partner/Manager who signed above: BY - By e ,. osrrommot­,&* SPATE OF FL0410A ST. LUCIE court' TT, A 70 CERTIFY MAT PM E IIA HE CBUCK Engineering CB(!(K. Inc. Florida Certificate ofAuthoriaation 4 8064 Specialty Structural Engineering Evaluation Report Of FILE CA'hOPY Innovative Distribution, LLC d/b/a JM Metals JM "5V" Crimp Metal Roof Assembly for Florida Product Approval M g _ 000 q # FL 12966.6 ST. LUCIE COUNTY Florida Building Code 2007 BUILDING DIVISION Per Rule 9B-72 REVIEWED FOR CO NCE Method: 1 - D DATE REVIEWED BYE � Category: Roofing PLANS AND PERMIT Sub - Category: Metal Roofing MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE --------------- Product: ✓M "SV" Crimp Roof Panel Material: Steel Panel Thickness: 26 Gauge Minimum Net Coverage Width: 24" Maximum Coverage Support Type: Wood Deck Prepared for: Innovative Distribution, LLC d/b/a JM Metals 1505 Cox Road Cocoa, Florida 32926 Prepared by: James L. Buckner, P.E. Florida Professional Engineer # 31242 Florida Evaluation ANE ID: 1916 Project Manager: Diana Galloway Report No. 09-180-5V-24-S6W-ER Date: 8/21 / 0 9 Contents: Evaluation Report Pages 1 — 7 CBUCK, Inc. 1334 S. Killian Drive, Suite 4, West Palm Beach, Florida 33403 Phone: (561)491-9927 Fax: (561)491-9928 Website: www.ebuckine.net es L. Buckner, P.E. Florida P.E. # 31242 AUG 2 7 2009 FL #: FL 12966.6 Date: 08 / 21 / 09 Report No.: 09-180-5V-24-S6W-ER CBUCK Engineering Page 2 of 7 ISpecialty Structural Engineering CBUCK, Inc. Florida Certificate ofAuthorization # 8064 Manufacturer: Innovative Distribution, LLC d/b/a JM Metals FILE COPY Product Name: JM "5V" Crimp Product Category: Roofing Product Sub -Category Metal Roofing Compliance Method: State Product Approval Rule 913-72.070 (1) (d) Product Description: Lapped, Steel Roof Panel on Plywood Deck Panel Material / Standards: Material: Steel Yield Strength: 50 ksi Minimum Corrosion Resistance: Material shall comply with the Florida Building Code (FBC), 2007 Section 1507.4.3. Panel Dimension(s) Thickness: 26 Gauge Width: 24" Maximum (Net Coverage Width) Rib Height: 3/8" Support Type: Wood Deck (Design of support system is not included in this evaluation) Support Description: . 15/32" or greater plywood, or • Wood plank deck Slope Range: Minimum slope shall comply with FBC 2007, applicable sections including 1504.7 and in accordance with the manufacturer's recommendations. Underlayment: Underlayment shall be per manufacturer's guidelines as required in FBC Section 1507.4.5 Insulation: (Optional) Rigid Insulation Board, 3" maximum thickness and with a density of 2.25 pcf (lbs/ft) minimum or a compressive strength of 25 psi minimum. CBUCK Engineering FL #: FL 12966.6 Date: 08 / 21 / 09 Report No.: 09-180-5V-24-S6W-ER Page 3 of 7 CBUCK, Inc. Florida Certificate of Authorization # 8064 Specialty Structural Engineering Attachment Component Roof Panel Fasteners copy Description: Type: Hex -Head wood screws with Weather Seal Washers Size: #9-15 x 3/16" minimum penetration through deck Standard: ANSI/ASME B18.6.1 Corrosion Resistance: Per FBC Section 1507.4.4 or 1506.6 "JM 5V Crimp" Steel Roof Panel to Wood Deck Installation: (Refer to drawings on Pgs 5-7 of this report.) Design Uplift Pressure: Method 1: • Row spacing: 12" o.c. (along the length of the panel and within 3" from all ends) • Fastener spacing: Nominal pattern of 12" o.c. (along each row, located on top of every major corrugation) Method 2: • Row spacing: 12" o.c. (along the length of the panel and within 3" from all ends) • Fastener spacing: Nominal pattern of 12" o.c. (along each row located beside of every major corrugation) Install the system in compliance with the evaluated installation method(s). The installation method(s) described herein have been evaluated to address the scope of the evaluation. Refer to manufacturer's installation instructions as a supplemental guide for attachment. Method 1: - 85 PSF ( Safety Factor of 2:1 ) . Method 2: - 114.25 PSF ( Safety Factor of 2:1 ) FL #: FL 12966.6 Date: 08 / 21 / 09 Report No.: 09-180-5V-24-S6W-ER CBUCK Engineering Page 4of7 I CBUCK, Inc. Florida Certificate of Authorization # 8064 y SpecialtStructural Engineering Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in accordance with the Florida Building Code and Rule 913-72.070 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity through Keystone Certifications, Inc. (FBC Organization #: QUA 1824) Performance Standards: The product described herein has demonstrated compliance with: • UL580-94 — Test for Uplift Resistance of Roof Assemblies —with Revisions through February 1998 • UL 1897-98 — Uplift test for roof covering systems Standards Equivalency: Test standard TAS 125-03 meets or exceeds the test procedures prescribed in UL 580-94 with 98 Revisions and UL 1897-98. Code Compliance: The product described herein has demonstrated compliance with the Florida Building Code 2007, Section 1504.3.2. Evaluation Report Scope: This product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code, as related to Rule 913-72. Limitations and • Scope of "Limitations and Conditions of Use" for this evaluation: Condition of Use: This evaluation report for "Optional Statewide Approval" contains technical documentation, specifications and installation method(s) which include "Limitations and Conditions of Use" throughout the report in accordance with Rule 913-72.070. Per Rule 913-72.060, the Florida Building Commission is the authority to approve products under "Optional Statewide Copy Approval". • Option for application outside "Limitations and Conditions of Use" Rule 9B-72.070(1)(e) allows rational engineering analysis for "project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code". Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. • Fire Classification is outside the scope of Rule 913-72, and is therefore not included in this evaluation. Additional approved substrates may be added for Fire Classification purposes. • This report does not evaluate the use of this product for use in the High Velocity Hurricane Zone code section. (Dade & Broward Counties) Referenced Data: 1. TAS 125-03 Uplift Test By Hurricane Test Laboratory, LLC. (FBC Organization #TST ID: 1527) Method 1: Report 0223-0307-01; Test Date: 03 / 05 / 01 - 03 / 08 / 01 Method 2: Report 0223-0517-06; Test Date: 05 / 19 / 06 - 05 / 22 / 06 2. Quality Assurance By Keystone Certifications, Inc., (FBC Organization #QUA ID:1824) Innovative Distribution, LLC d/b/a JM Metals, Licensee #: 344 3. Certification of Independence By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization # ANE 1916) CBUCK Engineering FL #: FL 12966.6 Date: 08 / 21 / 09 Report No.: 09-180-5V-24-S6W-ER Page 5 of 7 CBUCK. Inc. Florida Certificate ofAuthorcation 8064 Specialty Structural Engineering Installation Method Innovative Distribution, LLC d/b/a JM Metals JM 115V" Crimp (26 Ga. Steel) Panel Attached to Plywood Deck 00c M T Profile Drawings 24" Maximum Net Coverage Typical Panel Profile View FILL'4VPY �Y !W] CBUCK Engineering FL #: FL 12966.6 Date: 08 / 21 / 09 Report No.: 09-180-5V-24-S6W-ER Page 6 of 7 CBUCK. Inc. Florida Certificate of Authorization # 8064 Specialty Structural Engineering Installation Method Innovative Distribution, LLC d/b/a JM Metals JM "W' Crimp (26 Ga. Steel) Panel Attached to Plywood Deck 12" o.c. Typical MPthnrl 1 Fastener Spacing Across Panel Width #9-15 Hex -Head Screw with Weather Seal washer 3/16" min. penetration thru deck Spaced 12" o.c. across the Panel FILE COPY Typical Assembly Profile View Fasteners - -15/32" or greater Plywood, or ragia insuiauon - Wood plank Thickness 3" Maximum Typical Assembly Isometric View CBUCK Engineering FL #: FL 12966.6 Date: 08 / 21 / 09 Report No.: 09-180-5V-24-S6W-ER Page 7 of 7 CBUCK, Inc. Florida Certificate ofAuthorLation 4 8064 Specialty Structural Engineering Installation Method Innovative Distribution, LLC d/b/a JM Metals JM 115VII Crimp (26 Ga. Steel) Panel Attached to Plywood Deck 12" o.c. Typical MPthnrl 2 Fastener Spacing Across Panel Width #9-15 Hex -Head Screw with Weather Seal washer 3/16" min. penetration thru deck Spaced 12" o.c. across the Panel Typical Assembly Profile View Fasteners - FILL.� vOPY 15132" or greater Plywood, or Rigid Insulation Wood plank Thickness 3" Maximum Typical Assembly Isometric View Property Appraiser - St.Lucie County, FL Page 1 of 1 PROPERTY RECORD CARD Howard B Warren II Record: 1 of 1 <<Prev Next >> Spec.Assmnt Taxes Exemptions Permits Home Print Property Identification Site Address 385 NETTLES BV ParcellD: 4502-501-0571-000-4 \��VUCIE��G2 Sec/Town/Range 02 :37S :41 E Account #: 120159 y� Map ID 45/02F Land Use: SF Res Zoning: HIRD City/Cnty- St Lucie County Ownership and Mailing Legal Description Owner: Howard B Warren II Allison B Warren NETTLES ISLAND INC, A CONDO -SECTION II PARCEL 385N Address: 1755 SW St Andrews Dr ANDPRO-RATA SHARE IN COMMON ELEMENTS (OR 1166-171 Palm City FL 34990 More... Sales Information Assessment 2010 Final Total Land and Building Date Price Cade Deed Book/Page 2010 Final: 228400 Land Value: 150000 Acres 0.04 8/18/1998 105000 00 WD 1166 / 1715 Assessed: 228400 Building Value: 78400 3/20/1982 100 01 WD 0952 / 2369 Ag.Credit: 0 Finished Area: 930 SgFt 2/1/1981 17300 00 CV 0354 / 0889 Exempt: 4/1/1976 12000 01 CV 0251 / 2010 Taxable: Taxes: 4747.11 BUILDING INFORMATION Exterior Features View: RoofCover: SD - Dim Shingle RoofStruct: HP - Hip ExtType: ISH1 - YearBlt: 1999 Frame: ISLANDHOUSE1 Grade: B- - B- EffYrBlt: 1999 PrimeWall: VS - Vinyl Siding StoryHght: 0010 - 1 Story No.Units: 1 SecWall: Interior Features BedRooms: 0 Electric: MX - MAXIMUM PrmintWall DW - Drywall FullBath: 2 HeatType: FHA - FrcdHotAir AvgHUFI: 1/2Bath 0 HeatFuel: ELEC - Electric Prm.Flors: CT - Tile -Ceramic %A/C: 100 %Heated: 100 %Sprinkled: 0 Special Features and Yard Items Land Information Type Y/S Qty. Units Qual Cond. YrBlt No. Land Use Type Measure Depth DOK2 - WOOD DOCK Y 1 264 AV AV 1999 1 0100-SF Res CIUA-Unit 1 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED. http://www.paslc.org/prc.asp?prclid=450250105710004 6/ 1 /2011