Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SUBMITTED PAPERS
Permit Number: St. Lucie County ©J Building & Zoning Department L� I t� 2300 Virginia Avenue SCANNSD Fort Pierce, FL 34982 BY 772-462-1553 St. Lucie County APPLICATION FOR REPLACEMENT OF WINDOWS, SKYLIGHTS, DOORS & OVERHEAD GARAGE R ORS SEE REVERSE SIDE FOR INSTRUCTIONS ,Q MATE: 1. LOCATION/SITE ADDRESS: U04- a/ �J/ � 1 1 1614 FL 2. PARCEL ID NUMBER: a 40 -'7DI - no 5G " C) U O '-rI SECT TWP RNG I MAP LU INTT 3. DESCRIPTION OF PROJECT OR WORK ACTIVITY: ct V 8OLy- -13 kO t4 & raeic- �)abr 4. TYPE OF STRUCTURE: SFR ✓ MOBILE HOME OTHER 5. OWNERS INFORMATION I 6. Name: Gv, E , t t1bIL�'i. NO� �£ Address: 11R O-f N' 37 Sl City: Pierce State: • L, Zip: 3 *912 Phone: 7 7 2- 9y D —1) 53o CONTRACTOR'S INFORMATION FL Reg/Cert #: County Cert #: SZ (o Business Name:y-U SL WAY 1tiIL• Windows, Swing Doors, Skylights, Fixed Glass Opening Design Pressure A.S.C.E - 7 Design . Pressure Product Manufacture Model # Method of Attachment # Florida Product Approval # 120 mph 1130 mph 1140 mph Windows & Skylights Exposure B Exposure C Overhead Garage Doors < 30' - F.B.C. Table 1609.6 (1) + 1609.6 (2) B- Size T6 X % 4 �� iTA FUZq C- Size 7. VALUE OF CONSTRUCTION: $ ! Zr1Sd no-t FEES DUE: IF RECEIPT: OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in 'nce with 11 applicab.{l�e'l"aws regulating nstruction and zoningr'L with Mcy� _ PRINT QUALIFIERS/OWNERS NAME SI=G—NA- T-URIX OF QUALIFIERJOWNER STATE OF FLORIDA, OF G BEFORE ACKNOWLEDGED E THIS DAY— F , 20%BY WHO IS PER�ip. KNOWN E OR WHO HAS PRODUCED AS IDENTIFICATI N. �— IG�TURE F OTARY TYPE OR PRINT NAME OF N TARY TITLE "NOTARY PUBLIC COMMISSION NUMBER ��P" Y KAREN LYNN EPISCOPO �9 MY COMiXESSION N EE33160 °" ' EXPIRES: ISea�rher 17, 2014 o� I— S rOTARY Fl. Nem-1 Dicccunt Assoc. Co. Miami -Dade County - Building -.^,:,de Compliance Office - Product Cont,-1 Search Page 1 of 1 MIAMMADE "1 Building Code Compliance Office Product Information Product Information for N.O.A. 06-0921.04 NOA 96-0921.04 File Classification High velocity hurricane zone Category Doors Subcategory Sectional Material Steel Applicant Wayne Dalton Corporation Status File Approved Expiration_Date December/13/2011 Impact —Rate Large and Small Missile Impact Maximum —Design —Pressure —Positive 46 Maximum —Design —Pressure —Negative 52 Description Waynemark 8000 & 8100 Raised Panel Steel Overhead Sectional Garage Door t:/ http://www.miamidade.gov/buildingcode/pc-result_app.asp?fldNOA=06-0921.04 5/23/2011 MIAMI•DADE BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION MIAMI-DADE COUNTY, FLORIDA METRO-DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130-1563 (305) 375-2901 FAX (305) 375-2908 NOTICE OF ACCEPTANCE (NOA) Wayne -Dalton Corporation 3395 Addison Drive Pensacola, FL 32514 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). -plc NON shiall-net-ba-fah"ter-the-expiration-date-- stated -bBlow: Phe iami- a e County ro uct ontrol Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Waynemark 8000 & 8100 Raised Panel Steel Overhead Sectional Garage Door APPROVAL DOCUMENT: Drawing No. 0114, titled "Waynemark 8000 & 8100 Raised Panel", sheets 1 through 2 of 2, prepared by Wayne -Dalton Corp., signed and sealed by W.S. Wilson, P.E., dated 06/27/01, with last revision P1 on 10/19/01,.bearing the Miami -Dade County Product Control Renewal stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Division. MISSILE IMPACT RATING: Large and Small Missile Impact LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved or MDCPCA", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. LIMITATIONS: This approval requires the manufacturer to do testing of all coils used to fabricate door panels under this Notice of Acceptance. A minimum of two specimens shall be cut from each coil and tensile tested according to ASTM E-8 by a Miami -Dade County approved laboratory selected and paid by the manufacturer. Every 3 months, four times a year, the manufacturer shall mail to this office: a copy of the tested reports with confirmation that the specimens were selected from coils at the manufacturer production facilities, and a notarized statement from the manufacturer that only coils with yield strength of 40ksi or more shall be used to make panels for Miami -Dade county under this Notice of Acceptance. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA # 01-0813.06 and, consists of this page, evidence page E-1 as well as approval document mentioned above. The submitted documentation was reviewed by Jaime D. Gascon, P.E. NOA No 06-0921.04 �(A$Cfi"1 Expiration Date: .De�ceni_ber' k201� Zg '� Approval Date: February 15, 2007 Page 1 Wayne -Dalton Corporation NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. 0114, titled "Waynemark 8000 & 8100 Raised Panel", sheets 1 through 2 of 2, prepared by Wayne -Dalton Corp., signed and sealed by W.S. Wilson, P.E., dated 06/27/01, with last revision Pl on 10/19/01. B. TESTS -it. IestReport on Large Missile Impact Test and Cyclic Wind Pressure Test of "Sectional Residential Garage Door Waynemark 8000-0114" prepared by Hurricane Engineering and Testing Inc. Report #01-993 dated 04/03/01 signed and sealed by HM Medina, PE. 2. Test Report on Uniform Static Air Pressure & Forced Entry Resistance Test "Sectional Residential Garage Door Waynemark 8000-0114" prepared by Hurricane Engineering and Testing Inc., Report No. 01-992, dated 04/02/01, signed and sealed by HM Medina, PE. 3. Test Report on ASTM B 117-90 Test of T x9" galvanized panels (controls) & painted panels prepared by Sub -Tropical Testing Service, Test Number WDC-1, dated 04/26/01, signed and sealed by Mark Mosbat, P.E. C. CALCULATIONS 1. Anchoring Method Summary, prepared by W. S. Wilson, Sheets 1 through 5 prepared, signed and sealed by W. S. Wilson, PE on 08/02/01. D. QUALITY ASSURANCE 1. Building Code Compliance Office. E. MATERIAL CERTIFICATIONS 1. Tensile Test Report No-HETI 01-T034, prepared Hurricane Engineering & Testing, Inc., dated 04/05/01, signed and sealed by H. M. Medina, PE. F STATEMENTS 1. Letter of code compliance issued by Wayne -Dalton Corporation, signed & sealed by W. S. Wilson, PE. on 08/02/01. 2. Letter of No Financial Interest issued by Wayne -Dalton Corporation, signed & sealed by W. S. Wilson, PE on 08/02/01. 3. No change in product since last approved letter issued by Wayne -Dalton Corporation on 09/11/06, signed by W.S. Wilson, P.E. Jaime D. ascon, P.E. Chief, Product Control Division NOA No 06-0921.04 Expiration Date: December 13, 2011 Approval Date: February 15, 2007 E-1 MUNIG ANGLE :K KETS X = SECTION HEIGHT VINYL OR WOOD DOOR STOP ' 2 (NAILED ON 6' CENTERS) MUST OVERLAP TOP AND BOTH ENDS OF PANELS MINIMUM 7/16" TO MEET NEGATIVE PRESSURES / 5/16XI-5/8' 16GA END ® LAG SCREW SYP 0.53 OR BETTER ATTTACHED JAMS 2.8 — TO 2000 PSI CONCRETE WITH 5/16" SIMPSON SLEEVE ALL AT JB-U5 BRACKET 2 0 10-1/2" O.C. WITH MIN EMBED I 16CA OF 2' 1/4-20x9/16" BOLT -L. ® AND NUT NOTE: i TOTAL AREA OF LOUVERS CANNOT EXCEED 60(IN2) 2' VE0TTRACK OPTIONAL - .080" (MIN) ALUMINUM LOUVERS WITH HK WIDE EDDY HIGH IMPACT STYRENE FRAME MAY BE LOCATED IN END HINGE THE END PANELS OF THE BOTTOM SECTION. TO MEET MINIMUM VENTILATION RFOUIRFMFNTZ (1) JB-US BRACKET LOCATED AT EACH ROLLER LOCATION EXCEPT TOP BRACKET ROLLER (P/N 125139) If SEE CHART FACER STEEL IS 24GA MINIMUM, FORMING FS TYPE / 13 STEEL, 40 KSI MINIMUM, ' PER ASTM A653-00, WITH A FINISH EQUAL TO ASTM A525 MADE UP OF A C90 / ' FINISH COVERED PATH TWO COATS OF POLYESTER PAINT (1) JB-US BRACKET LOCATED AT THE MIDDLE OF EACH SECTION EXCEPT TOP SECTION A`� I SECTION A —A MAX WIDTH � 3.72' MIN EDGE GIST. 5/16" SIMPSON STRONG TIE® � BAUSRC CHEMICAL SLEEVE ALL, 2" MIN EMBED ADHESIVE 1100 TYP INTO 2000 PSI CONCRETE l 42.8 1 FRODUCP RENEWED u complying with 16e Flo ift Braiding Cde Ampfnutt No o4-O 2 •o Etpinti0n Dat TRACK STEEL TO ® / BY HAVE A MINIMUM Mhml ePmdtltlCoedd , YIELD OF 33,000 PSI Division 18GA NARROW BODY,J INTERMEDIATE HINGE SECTION B—B DOOR HEIGHT U-BARS SECTION HEIGHTS BOTTOM #2 #3 #4 #5 #6 #7 TOP JB-US BRACKETS 6'-6" 7 21" 18" 18" 21" 7 7'- 0" 7 21" 21" 21" 21" 7 7'- 6" 9 88" 18 18 7g" t8" 9 8'-0" 9 21" 18" 18" 1g" 21" 9 9'-0" 11 18" 18" 18" 18" 18" 18" 11 107- 0" 11 21" 21" 21 18" 18" 21" 11 117- 0" 13 21" 18" 18" 18" 18" 18" 21" 13 12'- 0" 13 21' 21 21 21" 21" 21" 18" 13 13'- 0" 15 21" 21" 21" 18" 18" 18" 18" 21" 15 14'- 0" 15 21" 21" 21" 21" 21" 21" 15 r - I- .25 NYLON ROLLER WITH 5-1/2" STEMS AND .63 MAX 7/16' PUSH NUT AT EACH END 4 Approved: _ W.S. 'Mlsm, P.E. 3395 PDOISON DR.. PENSAEgA FL 32514 FTDRDA CDTMOOX91 N0: 0046489 c GEORGW CMnMTXIN No. 018519 NORTH ovnTDN4 C NnRCMION NO. 023936 Date: /,(— ^7_ p 1 APPM740 AAS COMPLIHIS Willi THE SOUTH DATE DEeID' OUi2 fl CODE ar �jj1l _ LYODUCF�MI OL MEIN tUILDIN CODE COMPLIANCE OFFICE bCf,E;TiAHCE HO.OI—O$\�_O.F� �a P3395 OLA ROAOOISONRIOAV32OR E 514 DRAWN 6/2 FNSACCHECKE (850) 474-9890 APPR WAYNEMARK 8000 & 8100 RAISED PANEL DESIGN PRESSURE: +46.0 PSF/-52.0 PSF PART N0. 294822 SHEET 1 OF 2 0114 1 P1 (3) 1/4-20x7/8' TEK SCREWS PER BRACKET (P/N 100507) BOTTOM BRACKET (P/N RH-270354, LH-270355) 14GA ° 0 4.00 I O II� -'1 2.25 -� 2.25 F- 1 BOTTOM 13RACKET— \S2j (2) 1/4-2Ox9/16' TRACK BOLTS & (2) 1/4-20 HEX o NUTS THRU ANY 2 ALIGNING HOLES (5) 1/4-20x5/8' TEK SCREWS (P/N 141658) -1 2.75 f- t 12 A 5.44 0 0 0 i- 2.90 �p TOP BRACKET �S (P/N 108077)- 1 2.40 (P/N 100320) AO180A NARROW BODY HINGE gENTER HINGE TYP_ \52j (2) 1/4-20x5/8- TEK SCREWS ALL END HINGES 2.72 2- °� 9D o 7.36 LH O RH (4) 1/4-2Ox5/8' SELF- (2) 14GA WOE THREADING SCREWS BODY END HINGE: (P/N 1G0320) ,iL�BOTTOM END, HINGE ,_ ,52 i )z1-5/8' LAG SCREW DRILL .281 OR 09/32 HOLE IN TRACK FOR JB-US BRACKETS 1/4-2016" TRACK BOLT & 1/4-20 HE. NUT AT EACH JB-US BRACKET �3.75 1.95� O I 1.25 Q[ONSIDE SIDE LOCK_ _ _ - / 4.Q"JB_ US BRACKET_ —r 2 (SHOWN IN LOCKING POSITION) (P/N 125139) 16GA ONE PER SIDE 2x6 JAMB 2.09 13GA ADJ TOP BRACKET 5.48 °OD 1-1/2'xl-1 /2'z13GA 13GA HORIZONTAL ANGLE 1 1.50 �0000 (4) 5/16z1-5/8" SEE LAG SCREWS P 15.07 2' HORIZONTAL TRACK .067" THK (2) 1/4-2ox9/16' TRACK BOLTS & (2) 1/4-20 HEX NUTS 1.96 �LFLAG ANGLE - \52/ SEE INTRUCTION MANUAL FOR MORE DETAILS ON ASSEMBLY OR OPERATOR REQUIRED r .5 _1 .5 3' 20GA BOKSI -MINIMUM U-BAR', rrP TOP BRACKET 1 (2) 1/4-20x5/8' TEK SCREWS ATTACHED AT EACH STILE PLACE U-BARS SAS SHOWN �- TOP SECTION `52/(SOME OOOR COMPONENTS OMITTED FOR CLARITY) SEE INTRUCTION MANUAL FOR MORE DETAILS ON ASSEMBLY SE ON (4) 1/4-204/8' SELF - THREADING SCREWS (P/N 100320) 2.72 (2) 1/4-20x5/8' TEK SCREWS 000 eO 7.36 !l O LH O O RH (2) 14GA WIDE BODY END HINGES [E2- END HINGE_TYP J 9•xO. 58" fOM SEAL INN itKMtUlA 1E SECTION-- l/ �Szj (soME DOOR COMPONENTS LOCK & ADDITIONAL iLE' OM SECTION OMITTED FOR CLARITY)Cl-'INTERMEDIATE SECTIONS '\ �"OME DOOR COMPONENTS ((-- )-•------------- �52�(SOME DOOR COMPONENTS `S�i(SOME DOOR COMPONENTS OMITTED FOR CLARITY) OMITTED FOR CLARITY) Approved: - WS Wlsm, RE 3395 ADDISON DR.. PENS^LOIA FL 32514 FLORIDA CERIOTGTION NO. 0048489 GEORGIA CERTe1GW10.N N0. 0185I9 NORTH CAA0lJNA CERTIFICATION 10. 013B36 Date: ((_ 77- p rRODIJCTNRf1�11� w complying wHA theP1mift Buiding Code ATmeptance No `0 APPROVED AS C014MING WITH THE SOUTH FLORIDA BUILDING CODE D►,rE DEC La. _ BUILIHN6 CODE COMPLIANCE OFFICE EI IEatlua Date gr. 3396 AGO, N DRIVE DRAWN 6/2 PENSACOLA FLORIDA 32514 By� (850) 474-9890 APPRKED Mlrlm dePTadactd; WAYNEMARK 8000 & 8100 RAISED PANEL Dil6sion DESIGN PRESSURE: +46.0 PSF/-52.0 PSF PART NO. 294822 R & D RELEASE TO PRDo6CT °xs ENCINEERINO or. P CHANCES 11 REV NOTES AND )ESCR PER CADE 711Y NARK UPS. 10/19/01 DM i SHEET 2 D< 2 OPTION CODE REV 0114 P1 Florida Building Code Online , Page 1 of 1 BCIS Home I Log In I User Registration I Hot Topics ( Submit Surcharge I Stats & Facts ( Publications I FBC Staff I BCIS Site Map I Links I Search Product Approval USER: Public User Product Approval Menu > Product or Aoolication Search > Application List Search Criteria Refine Searcl Code Version 2007 FL# 9166 Application Type ALL Product Manufacturer ALL Category ALL Subcategory ALL Application Status ALL Compliance Method ALL Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL Product Model, Number or NameALL Product Description ALL Approved for use in HVHZ ALL Approved for use outside HVHZ ALL Impact Resistant ALL Design Pressure ALL Other ALL Results - ADDlications F� Tvue Manufacturer Validated By Status FL9166-R3 Revision Wayne -Dalton, a division of Overhead Door Corporation Dole ]. Kelley Approved History (904) 396-5885 Category: Exterior Doors Subcategory: Sectional Exterior Door Assemblies i*Approved by DCA. Approvals by DCA shall be reviewed and ratified by the POC and/or the Commission if necessary. i Department of Community Affairs Florida Building Code Online Codes and Standards 2555 Shumard Oak Boulevard Tallahassee, Florida 32399-2100 (850) 467-1824, Fax (850) 414-8436 © 2000-2010 The State of Florida. All rights reserved. Privacy Statement i Copyright Statement i Accessibility Statement i Plug-in Software i Customer Service Survey i Contact Us Product Approval Accepts: ® N securitv+u:-csttcs Wrlsign Trusted VENT FY � hftp://vrww.floridabuilding.org/pr/P_app_lst.aspx 5/23/2011 Florida Building Code Online Page 1 of 2 s } lit. -£ '- BCIS Home Log In User Registration Hot Topics ( Submit Surcharge Stats & Facts Publications ( FBC Staff BCIS Site Map Links Search I -., Product Approval 0 USER: Public User a Product Approval Menu > Product or Application Search > Application List > Application Detail + FL # FL9166-R3 Application Type Revision • s• Code Version 2007 Application Status Approved Comments + Archived Product Manufacturer Wayne -Dalton, a division of Overhead Door Corporation Address/Phone/Email 3395 Addison Drive Pensacola, FL 32514 (850) 475-6000 gtaylor@Wayne-Dalton.com Authorized Signature Greg Taylor gtaylor@Wayne-Dalton.com Technical Representative Greg Taylor Address/Phone/Email 3395 Addison Drive Pensacola, FL 32514 (850) 474-9890 gtaylor@wayne-dalton.com Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Sectional Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who Jeffrey P. Arneson developed the Evaluation Report Florida License PE-58544 Quality Assurance Entity Intertek Testing Services NA Inc. - ETL/Warnock Hersey Quality Assurance Contract Expiration Date 03/20/2028 Validated By Dole J. Kelley �i Validation Checklist - Hardcopy Received Certificate of Independence FL9166 R3 COI Cert Ind.pdf Referenced Standard and Year (of Standard) Standard Year TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By http://www.floridabuilding. org/prlpr_app_dtl. aspx?paratn=wGEVXQwtDgsL%2b2sNOQ... 5/23/2011 Florida Building Code Online Page 2 of 2 Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Method 1 Option D 02/12/2010 04/29/2010 07/11/2010 08/10/2010 Summary of Products FL # IMlodel, Number or Name f6escriptlo, 9166.1 118024 / 8124 #1300 9' Max Width, 14' Max Height. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL9166 R3 II 1300 P2.pdf Approved for use outside HVHZ: Yes Verified By: Jeffery P. Arneson FLORIDA PE 58544 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: +46.00/-52.00 Evaluation Reports Other: FL9166 R3 AE FL9166 Evaluation Report - 8024- 124. df Created by Independent Third Party: Yes 9166.2 118024 / 8124 #1320 16' Max Width. 14' Max Height. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL9166 R3 II 1320 P2.pdf Approved for use outside HVHZ: Yes Verified By: Jeffery P. Arneson FLORIDA PE 58544 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: +46.00/-52.00 Evaluation Reports Other: FL9166 R3 AE FL9166 Evaluation Report - 8024- 8124.pdf 11 Created by Independent Third Party: Yes 9166.3 118024 / 8124 #1340:]FIB' Max Width. 8' Max Height. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL9166 R3 II 1340 P3.pdf Approved for use outside HVHZ: Yes FL9166 R3 II 312957 P5 8000-8024-8100-8124 Post. pdf Impact Resistant: Yes Design Pressure: +46.00/-52.00 Verified By: Jeffery P. Arneson FLORIDA PE 58544 Other: Created by Independent Third Party: Yes Evaluation Reports FL9166 R3 AE FL9166 Evaluation Report - 8024- 8124.pdf Created by Independent Third Party: Yes Back Next Department of Community Affairs Florida Building Code Online Codes and Standards 2555 shumard Oak Boulevard Tallahassee, Florida 32399-2100 (850) 487-1824, Fax (850) 414-8436 p 2000-2010 The State of Florida. All rights reserved. Product Approval Accepts: NWEA securit 'CS VerlSlgn Trusted 6 IRVCY -D- http://www.floridabuilding. org/pr/Pr_app_dtl. aspx?param=wGEVXQwtDgsL`/`2b2sNOQ... 5/23/2011 A 1. IMPACT RESISTANT GLAZING SYSTEM 13 GA HORIZ ANGLE MAY BE INSTALLED IN TOP OR INTERMEDIATE SECTION (WITH OR WITHOUT DECORATIVE INSERTS). GLAZING SHALL 13 GA FLAG ANGLE ' BE 1/4" MAKROLON—AR POLYCARSONATE (MIAMI—DADE NOA #07-0313.04) OR EQUAL. MAXIMUM GLAZING DIMENSIONS 15 GA MIN HORIZ SHALL BE 18.56" x 12.26". SEE DETAIL TRACK E ON SHEET 2 FOR ASSEMBLY DETAILS. — 2. VINYL OR WOOD DOOR STOP NAILED A 4 LAG SCCREWREW (MINN 4 MAXIMUM OF 6" O.C. MUST OVERLAP TOP AS SHOWN) .� AND BOTH ENDS OF PANELS MINIMUM 7/16" TO MEET NEGATIVE PRESSURES. 15 GA MIN VERT m TRACK 3. KEY LOCK, SLIDE LOCKS, OR OPERATOR REQUIRED. 4. SECTION STEEL TO HAVE A MINIMUM 0. 0 24 GA THICKNESS WITH A MINIMUM G90 COATING AND A MINIMUM YIELD STRENGTH OF 33.8 KSI. 1/4-20x9/16* TRACK BOLT AND 1/4-20 HEX 5. THE DESIGN OF THE SUPPORTING NUT AT EACH JB—US STRUCTURAL ELEMENTS SHALL BE THE JAMB BRACKET LOCATION RESPONSIBILITY OF THE PROFESSIONAL OF RECORD FOR THE BUILDING OR STRUCTURE AND IN ACCORDANCE WITH 5/16x1-5/8" LAG CURRENT BUILDING CODES FOR THE SCREW AT EACH LOADS LISTED ON THIS DRAWING. JAMB BRACKET 0• o 6. WOOD SUBSTRATE FOR DOOR JAMB IS A TO BE MINIMUM 2x6 NO. 3 SOUTHERN PINE. REFER TO SHEET 3 FOR ATTACHMENT TO SUPPORTING STRUCTURE. FOR DIRECT MOUNTING OF JAMB '0)' BRACKETS TO OTHER SUBSTRATES, SEE 15 GA STIFFENED JAMB DETAIL SHEET 2. FOR MOUNTING OF JAMB BRACKETS m CONTINOUS WALL ANGLE, SEE CONTINOUS SEE SCHEDULE FOR WALL ANGLE DETAIL SHEET 3. QUANITY, LOCATION, AND TYPE 7. FOR LOW HEAD ROOM LIFT c CONDITIONS, TOP BRACKET SHALL BE A KEY LOCK OR SLIDE LOCK Q• 13 GA LHR 7/4 TOP BRACKET WITH A EACH END (NOT REQUIRED MINIMUM OF (3) 1/4-140/8" SELF WITH OPERATOR — SEE DRILLING CRIMP71TE SCREWS IN LIEU OF NOTE 3). SLIDE LOCK THE BRACKET SHOWN ON THIS DRAWING. SHOWN FOR CLARITY U—BAR ON TOP SECTION SHALL BE .�. INSTALLED ON TOP OF LHR TOP BRACKETS. m B. LOUVERS MAY BE INSTALLED ON THE A NOTE: (4) ( ) SECTION SOLID DOOR IF THE TOTAL AREA OF THE DOOR SHOWN. SEE SHEET 2 LOUVER DOES NOT EXCEED 120 SQUARE FOR U—BAR LOCATIONS ON INCHES. DOORS WITH OTHER SECTION QUANTITIES AND SEE NOTE 1 9. DOORS WITH DECORATIVE OVERLAY ARE LIMITED TO A MAX SIZE OF 12' WIDE THIS SHEET FOR GLAZING BY 8' HIGH FOR THIS OPTION CODE. OPTIONS. SUPERIMPOSED DESIGN PRESSURE LOADS ON SUPPORTING STRUCTURE DOOR WIDTH DOOR HEIGHT UNIFORM LOAD EACH JAMB (PLF) 10'-0" ALL +230.0/-260.0 12'-0" ALL +276.0/-312.0 14'-0" ALL +322.0/-364.0 15'-0" ALL +345.0/-390.0 16'-0" ALL +368.0/-416.0 JAMB BRACKET SCHEDULE DOOR HEIGHT NO. OF SECTIONS NO. OF JAMB BRACKETS (EACH JAMB) LOCATION OF CENTERUNE OF JAMB BRACKETS MEASURED FROM BOTTOM OF TRACK (ALL DIMENSIONS f 2") 6'-6" 4 7 JB—US , 10 JB—US , 21-3 4 JB—US , 29-3 4 JB—US , 39 JB—US , 48 JB—US , 57-1 4 JB—US 7'-0" 4 7 " (JB—US), 10" (JB—US), 21-3/4" (JB—US), 29-3/4" (JB—US), 42" (JB—US), 52-1/2" (JB—US), 63-1/4" (JB—US) 7 —6 5 8 JB—US , 10 JB—US , 18-3 4 JB—US , 26— 4 JB—US , 36 JB—US , 45 JB—US , 4-1 4 JB—US , 74-1 2 JB—US 8 —0 5 8 JB—US , 10 JB—US , 21-3 4 JB—US , 29-3 4 JS—US , 39 JB—US , 48JB—US , 57-1 2 JB—US , 75-1 2 JB—US 8-0 EE NOTE BELOW NOSE: (JB—US) FOLLOWING DIMENSION DENOTES SLOTTED JAMB BRACKET ATTACHED TO TRACK WITH 1/4-2Dx9/16" TRACK BOLT AND NUT AS SHOWN ABOVE. ALL DOORS GREATER THAN 8' IN HEIGHT OR WITH DECORATIVE OVERLAY REQUIRE USE OF CONTINUOUS WALL ANGLE. SEE SHEET 3 FOR DETAILS. A � DOOR I I REVISIONS MARK R. BARROW, PE FLORIDA LICENSE NO. 57389 Wayne® palton STATIC PRESSURE RATINGS APPROVED SIZES SC DESIGN (PSF): +46.00/-52.00 MAX WIDTH: 16'-D" TEST (PSF): +69.00/-78.00 MAX HEIGHT: 14'-D" DF IMPACT/CYCLIC RATED (YES/NO): YES MAX SECTION HEIGHT:21" CF MODELS 8024/8124 3395 ADDISON DRIVE PENSACOLA, FLORIDA 32514 (850) 474-9890 WINDLOAD SPECIFICATION OPTION CODE 1320 P7 MODIFIED NOTES AND TRACK NOTE FOR DOORS WITH DECORATIVE OVERLAYS. ADDED CONTINUOUS WALL ANGLE DETAIL SHEET 3. UPDATED NOTES FOR CONTINOUS WALL ANGLE MOUNTING. GIRT 10/1/07 P2 ADDED IMPACT RESISTANT GLAZING. MODIFIED NOTES SHEET 1 FOR GLAZING. ADDED DETAIL E SHEET 2 FOR GLAZING. GIRT 11/10/07 N.T.S. SIZE: A DATE NAME 1 2/22/07 CRT ED 5/4/07 MRB SHEET 1 OF 3 DRAWING PART NO. I REV. 329929 P2 REVISIONS 4CKET WITH 5/16-18 BOLT & NUT CENTER SLOT AND 1/4-20x9/16" 1CK BOLT & 1/4-20 HEX NUT ?OUCH ANY TWO ALIGNING HOLES 13 GA COMMERCIAL 'A' I 4ME TOP BRACKETS EACH \ AACHED WITH (4) 1/4-14x7/8' _F DRILLING CRIMPTITE SCREWS •�• / (2) 1/4-140/8' DETAIL A F DRILLING CRIMPTITE SCREWS SIDE OF EACH INSIDE END HINGE) - STEEL ROLLER WITH 9" GRADE 4 OR EQUIVALENT STEM AND 6' PUSHNUT AT EACH ROLLER / :ATION. 1/4" MAX BETWEEN I iHNUT AND BRACKET OR HINGE------ -ti 14 GA WIDE BODY END / GES EACH ATTACHED WITH 1/4-140/8" SELF 14 GA WIDE BODY INTERMEDIATE HINGE ATTACHED WITH (4) 1/4-140/8' SELF DRILLING DETAIL C GA EXTENSION BRACKET THROUGH STRUT AND BRAT GA BOTTOM BRACKET (ACHED WITH (2) I-147/8- SELF DRILLING MPTITE SCREWS THROUGH WT AND BOTTOM BRACKET ) (1) 1/4-145/8" SELF LUNG TAMPER RESISTANT DEDETAILD MARK R. BARROW, PE FLORIDA LICENSE NO. 57389 16' (8) SECTION DOORS i 14'2" & 15' - i 1 LOCATED AS SHOWN D N DOORS WITH KSI U-BARS TED AS SHOWN REWS ON, TYP. I 0 F WITHWITly H(16) 3' 18 GA 80 KSI U-BARS LOCATED AS SHOWN (14) 3' 18 GA BO KSI U-BARS LOCATED AS SHOWN (7) SECTION DOORS WITH (12) 3" 18 GA BO KSI U-BARS LOCATED AS SHOWN (6) SECTION DOORS WI ) SECTIO SNLESS SCREWS WITH NON-STRUCTURAL DECORATIVE (8) 3" 18 STAINLESS 18 GA 8 STANLESS BACKED / OUTER WINDOW TRIM LOCA RUBBER WASHERS 1/8' BEAD GE / -� \ 1/4' POLYCARBONATE ULTRAGLAZE \ SSG4000AC L _ _ �' ATTACH U-BAR WITH STRUCTURAL (2) 1/4-14x7/8' SEL SEALANT OR DRILLING CRIMPTITE SC EQUIVALENT AT EACH STILE LOCATI FACER STEEL �� 2 3/4- MIN EDGE DIST NON-STRUCTURAL DECORATIVE INNER WINDOW TRIM A DETAIL E 3/8" SIMPSON TITEN HD, 2-3/4- MIN EMBED INTO MIN 2000 PSI CONCRETE FOR EACH JAMB BRACKET LOCATION - JAMB BRACKET 1/4-20x9/16" TRACK BOLT AND 1/4-20 HEX NUT ,CK NOTE FOR DOORS � H DECORATIVE :RLAYS. ADDED lTINUOUS WALL ANGLE 'AIL SHEET 3. IATED NOTES FOR ITINOUS WALL ANGLE 1NTING. 10/1 /07 ADDED IMPACT lISTANT GLAZING. )IFlED NOTES SHEET 1 11 /10/07 CONCRETE MOUNTING DETAIL STATIC PRESSURE RATINGS APPROVED SIZES SCALE: N.T.S. SIZE: A Wayne® DESIGN (PSF): +46.00/-52.00 MAX WIDTH: 16'-0" DATE NAME TEST (PSF): +69.00/-78.00 MAX HEIGHT: 14'-0" DRAWN 2/22/07 GRT Dalton IMPACT/CYCLIC RATED (YES/NO): YES MAX SECTION HEIGHT:21" CHECKED 5/4/07 MRB MODELS 8024/8124 SHEET 2 of 3 3395 ADDISON DRIVE DRAWING PART N0. REV. PENSACOLA, FLORIDA 32514 WINDLOAD SPECIFICATION OPTION CODE 1320 329929 P2 (650) 474-9890 PUCE PLATE 14' MAX i 12' MAX 12" SEE CUP DETAIL MAX THIS SHEET 12' I MAX 12' i T 12' M TAX I CUPS TO BE EITHER BOLTED OR WELDED. SEE DETAILS THIS PAGE. 13 GA MIN TRACK CONTINUOUS WALL ANGLE 0 1 o J MIN 11 GA (3) 1/4"-20 TRACK CLIP OR CARRIAGE BOLT WITH 1/4"-20 NUT TYPICAL CLIP BOLTING DETAIL IRS W 0.28" 2 0 MIN 11 GA CUP (1) 1/4"-20 TRACK 13 GA MIN OR CARRIAGE BOLT CONTINUOUS WITH 1/4"-20 NUT WALL ANGLE TRACK TYPICAL CLIP .WELDING DETAIL 2 3/4' MIN EDGE DIST • 5/16" LAG SCREW INTO 2 3/4" ±1' MIN 2 x 6 LUMBER AT EDGE +"EN EACH HOLE LOCATION RACK 3/8" SIMPSOHD, 2-3/4" CONTNUOUS WALL ANGLE EMBED INTO 2000 PSI CO/4-2Ox9/16' TRACK BOLT FOR EACH HAND 1/4-20 HEX NUT LOCATION AP, CONTINOUS WALL ANGLE DETAILS MARK R. BARROW, PE FLORIDA LICENSE NO. 57389 MAX SPACING OF ANCHORS/SCREWS PER JAMB (IN) 3/8" SIMPSON TITEN 3/8" SIMPSON TITEN 3/8' X 3" LONG HD SCREW ANCHOR TO MINIMUM 2000 PSI HD SCREW ANCHOR TO MINIMUM 2000 PSI LAG SCREW"' CONCRETE'""' GROUT FILLED CMU`° 22 19 18 1. BASED ON 3/8" SIMPSON TITEN HEAVY DUTY SCREW ANCHOR WITH A 1" O.D. WASHER INTO CONCRETE WITH A MINIMUM EMBEDMENT DEPTH OF 2-3/4" AND A MINIMUM EDGE DISTANCE OF 2-3/4'. 2. BASED ON 3/B" SIMPSON TITEN HEAVY DUTY SCREW ANCHOR WITH A 1" O.D. WASHER INTO GROUT FILLED CMU WITH A MINIMUM EMBEDMENT DEPTH OF 2-3/4% A MINIMUM EDGE DISTANCE OF 4", AND A MINIMUM END DISTANCE OF 4". CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90 AND GROUT SHALL CONFORM TO ASTM C476. 3. BASED ON 3/8' DIAMETER x 3" LONG LAG SCREWS WITH 1" O.D. WASHERS WITH A 1-9/32' THREAD PENETRATION INTO SEASONED DRY WOOD SUPPORTING STRUCTURE. 4. PROVIDE QUANTITY OF SCREW ANCHORS OR LAG SCREWS AS REQUIRED TO MAINTAIN MAXIMUM SPACING AS SHOWN IN TABLE WITH A MINIMUM OF THREE (3) SCREW ANCHORS OR LAG SCREWS PER JAMB. SCREW ANCHORS OR LAG SCREWS AT TOP AND BOTTOM OF JAMB SHALL BE PLACED A MAXIMUM OF 6" FROM THE END OF THE JAMB. 5. LOAD PER JAMB CALCULATED TO BE A MAXIMUM OF +36B.O/-416.0 LBS PER FOOT. 6. CHART INCLUDES A SAFETY FACTOR OF 4. 7. DOOR JAMB TO BE MINIMUM 2x6 NO. 3 SOUTHERN PINE LUMBER (MIN) MOUNTED DIRECTLY TO SUPPORT STRUCTURE. S. DESIGN OF THE SUPPORT STRUCTURE SHALL BE THE SOLE RESPONSIBILITY OF THE BUILDING DESIGNER AND SHALL BE DESIGNED FOR THE LOADS LISTED IN NOTE 5. 9. SCREW ANCHORS OR LAG SCREWS SHALL BE INSTALLED PER MANUFACTURER'S WRITTEN INSTRUCTIONS. i 6' MAX. MAXIMUM SPACING 6" MAX. STATIC PRESSURE RATINGS I APPROVED SIZES S( Wayne® DESIGN (PSF): +46.00/-52.00 IMAX WIDTH: 16,-0" TEST (PSF): +69.00/-78.00 IMAX HEIGHT: 14'-0" DF Dalton IMPACT/CYCLIC RATED (YES/NO): YES MAX SECTION HEIGHT: 21" C1 MODELS 8024/8124 3395 ADDISON DRIVE PENSACOLA, FLORIDA 32514 WINDLOAD SPECIFICATION OPTION CODE 1320 (850) 474-9890 REVISIONS MODIFIED NOTES AND ,CK NOTE FOR DOORS I DECORATIVE '.RLAYS. ADDED ITINUOUS WALL ANGLE AIL SHEET 3. 'ATED NOTES FOR ITINOUS WALL ANGLE INTING. 10/1/07 ADDED IMPACT ISTANT GLAZING. )IFIED NOTES SHEET 1 GLAZING. ADDED AIL E SHEET 2 FOR ZING. 11/10/07 N.T.S. SIZE: A DATE NAME 1 2/22/07 CRT ED 5/4/07 MRB SHEET 3 OF 3 DRAWING PART NO. REV. 329929 P2 Ir Jax Apex Technology, Inc. FBPE CA No. 7547 4745 Sutton Park Court, Suite 402 Jacksonville, FL 32224 Evaluation reports are the opinion of the engineer who prepared the report, based on the findings, and in no way constitute or imply approval by a local building authority. The engineer, in review of the data submitted, finds that, in his opinion, the product, material, system, or method of construction specifically identified in this report conforms with or is a suitable alternate to that specified in the Florida Building Code, SUBJECT TO THE LIMITATIONS IN THIS REPORT Jeffrey P. Arneson, an employee of Jax Apex Technology, Inc. (Apex Technology), is the authorized evaluating engineer of this report. Apex Technology is the prime professional, as defined in Florida Rule 61 G-30.002, authorized to sell the engineering services performed by Jeffrey P. Arneson, and in no way is attempting to act as an approved evaluation entity. Neither Jeffrey P. Arneson, nor any other employee of Apex Technology, has performed calculations or testing for the products listed in this report. This evaluation is based solely upon the review, under the direct supervision of Jeffrey P. Arneson, of testing and/or calculations submitted by the manufacturer. The capacities listed in this report are based on the limiting capacities as determined from the substantiating data. We reviewed the substantiating data to a degree that allowed us to determine whether or not the work performed is consistent with the intended use of the product, and that the methods used are in compliance with, or meet the intent of, the Florida Building Code. All test reports were prepared by an approved testing laboratory. REPORT NO: WD200702-R1 CATEGORY: Doors and Windows SUBMITTED BY: Wayne Dalton A Division of Overhead Door Corporation 3395 Addison Drive Pensacola, FL 32514 1. CERTIFICATION OF INDEPENDENCE Jeffrey P. Arneson, the Florida engineer who prepared this report, and Apex Technology have no financial interest in the manufacturing, sales, or distribution of the products included in this report. Jeffrey P. Arneson and Apex Technology comply with all criteria as stated in Florida Administrative Code Chapter 96-72.110. 2. PRODUCT NAME Models 8024/8124 Garage Doors Page 1 of 4 Wayne -Dalton 3. SCOPE OF EVALUATION Structural Transverse Wind Loads and Large Missile Impact and Cyclic Wind Pressure Resistance. 4. USES Models 8024/8124 garage doors are used for residential and commercial applications with specified allowable design pressures. 5. DESCRIPTION General Models 8024/8124 doors are sectional overhead garage doors and are constructed of galvanized steel sections with a two coat polyester finish. The doors are two-inch thick raised panel doors with tongue and groove sections. They are the same door with one exception. The Model 8024 is non -insulated, the Model 8124 is insulated with 9/16-inch thick expanded polystyrene. They are constructed of a minimum 24 gage ASTM A653-00 galvanized FS Type B steel, and finished with an ASTM A525 made up of a minimum G-90 coating, covered with two coats of polyester paint. Each section is reinforced with 16 gage end stiles and 20 gage steel center stiles. The exterior steel skin may be overlaid with '/" thick non structural decorative overlay attached to the face of the door. Door Tracks All door assemblies listed in this report have both vertical and horizontal tracks with a minimum 15 gage, 33 ksi steel and finished with an ASTM A525 G-40 galvanized coating. The vertical tracks are attached to the supporting structure with jamb brackets or track clips and a continuous wall angle as specified on the most recent manufacturer's installation instructions/drawings. Wind Load Bracing All option code assemblies listed in Table 1 of this report are braced on the inside of the doors with three inch horizontal spanning U-bars. Each U-bar is made of either 18-gage or 20-gage ASTM A653-00 steel with a minimum yield strength of 80 ksi and are finished with an ASTM A525 minimum G-40 galvanized coating. The gage and quantity of U-bar braces varies depending on the amount of windload resistance required and the height of the door. In addition to three-inch horizontal spanning U-bars, option code 1340 listed in Table 1 of this report is braced with vertical aluminum posts made up of 0.125-inch thick 6063-T6 aluminum alloy. The post is a telescoping post assembly. The outer member outside diameter is 1.75" wide x 4.00" long. The inner member outside diameter is 1.47" wide x 3.72" long. Glazed Sections Option code assemblies listed in Table 1 this report with glazed openings that meet the requirements for impact resistance have glazing that is made of %" thick Macrolon-AR- Polycarbonate or an equivalent product approved for use in Florida, and can be installed in the top or intermediate sections of the garage door. These assemblies are available for use with the glazing option in wind-borne debris regions and are indicated so in Table 1. The maximum glazing dimensions shall be 18.56" x 12.26." Page 2 of 4 Wayne -Dalton Expanded Polystyrene Foam The expanded polystyrene foam used in this product is a 9/16" thick Type 1 EPS Foam molded by Drew Foam Company, Inc. The foam has a self -ignition temperature of 4700 C (878° F). The Flame Spread Index is zero for "ceiling only," and 5 for "ceiling and floor." The Smoke Developed Index is 0 for "ceiling burning only," and 50 for ceiling and floor." 6. INSTALLATION All option code assemblies listed in this report are to be installed in accordance with the most recent manufacturer's published installation instructions/drawings and this report. The most recent manufacturer's installation instructions/drawings shall be strictly adhered to and a copy of these instructions/drawings shall be available at all times on the job site during installation. 7. ALLOWABLE TRANSVERSE WIND LOADS Design wind load pressures for garage doors shall be determined in accordance with section 1609 of the current Florida Building code and/or section 1620 of the current Florida HVHZ Building Code and shall not exceed the allowable transverse wind loads shown in the following tables: Table 1: Models 8024/8124 Allowable Transverse Wind Loads and Impact Rating Windload Specification Option Code Maximum Size Positive Design PSF Negative Design PSF Reinforcement Glazing Available Yes/No Door Impact Resistant Yes/No Width Height 1300 9'-0" 14'4" 46.00 52.00 3", 20 gage U-bars Yes Yes 1320 16'-0" 14'4" 46.00 52.00 3", 18 gage U-bars Yes Yes 1340 18'-0" 8'-0" 1 46.00 1 52.00 1 3", 20 gage U-bars + (1) Aluminum Post Yes Yes 8. SUBSTANTIATING DATA 1. Garage Door Testing: Test Report Numbers: CTLA 1672W, CTLA 1672W-1, CTLA 1672W-2, CTLA 1672W-3, CTLA 1734W, CTLA 1734W-1, CTLA 1734-W2. Tests were performed in accordance with Miami -Dade County Protocol TAS-202 for transverse wind load and TAS-201 and TAS-203 for large missile impact and cyclic resistance by Certified Testing Laboratories, 7252 Narcoossee Rd. Orlando, FI 32822. 2. Expanded Polystyrene Foam Testing: "9/16" Thick Type 1 EPS Foam Molded by Drew Foam, Co., Inc., Moticello, MN."; ASTM E84-00a Surface Burning Characteristics of Building Materials Test Report No. 8939-109289 prepared by Omega Point Laboratories July 30, 2001 "Dylite M77B EPS FOAM"; ASTM D1929 Ignition Properties of Plastics Test Report No. 8942-91672 prepared by Omega Point Laboratories May 17, 1991 Page 3 of 4 Wayne -Dalton 3. Installation drawings and installation instructions prepared by Wayne -Dalton Corporation for each option code assembly listed in Table 1 of this report. 9. CODE REFERENCES Florida Building Code 2004/2007 Editions Section 1609 Wind Loads-Non-HVHZ Section 1620 Wind Loads-HVHZ Section 1626 Impact and Cyclic-HVHZ Section 1714.5.3.1 Static Testing-HVHZ and Non-HVHZ Section 2612 High Velocity Hurricane Zones — Plastics 10. REPORT SUMMARY Upon review of the data submitted by Wayne -Dalton, it is my opinion that the models as described in this report conform with or are a suitable alternative to the code standards and sections in the Florida Building Code 2004/2007 edition listed in section 9 of this report. 11. LIMITATIONS Any reference in this report to the manufacturer's "most recent" information is a direct reference to the most recent information submitted by Wayne -Dalton to the Florida Building Commission as part of their Florida Product Approval application for the option code assemblies listed in Table 1 of this report. This evaluation report and the most recent installation instructions, when required by the building official, shall be submitted at the time of permit application. The design of the supporting structural elements shall be the responsibility of the design professional for the building structure and in accordance with current building codes for the loads listed in Table 1 of this report. The doors shall not be located in areas where the transverse wind loads exceed the allowable loads shown in Table 1 of this report. 12. IDENTIFICATION Each Model series covered by this report shall be labeled with the man ufacturer's. name and/or trademark for field identification. 64 i '�ri �. a ology, Inc. fFie ,F, esop; P.E. December 171 2009 Page 4 of 4 Wayne -Dalton @ Wag,ne Dalton Jamb Connection Supplement This document provides a series of connection schedules and basic detailing concepts for the connection of garage door jambs to building frames with the use of various fasteners. DASMA Technical Data Sheet TDS-161 may be used as an alternate to this document. P/N 324620 Rev. P8 SCHEDULEI -" 3/8" DIAMETER LAG SCREWS MAXIMUM SPACING OF LAG SCREWS PER JAMB IN MAIN SUPPORT MEMBER SPECIES SYP SPECIFIC GRAVITY - 0.55 DOUGLAS FIR SPECIFIC GRAVITY - 0.46 SPF SPECIFIC GRAVITY - 0.42 LOAD PER JAMB (LB/NOTE 3 100 24 24 24 120 24 24 24 140 24 24 24 160 24 24 24 180 24 24 24 200 24 24 24 220 24 24 24 240 24 24 24 260 24 24 22 280 24 23 20 300 24 22 19 320 24 20 18 340 24 19 16 360 24 18 16 380 22 17 15 400 21 16 14 420 20 15 13 440 19 15 13 460 18 14 12 480 18 13 12 500 17 13 11 520 16 12 11 540 16 12 10 560 15 11 10 580 14 11 9 600 14 11 9 620 13 10 9 640 13 10 9 660 13 10 8 680 12 9 8 700 12 9 8 720 12 9 8 740 11 8 7 760 11 8 7 780 11 8 7 800 10 8 7 1. BASED ON 3/8" DIAMETER LAG SCREWS WITH 1" O.D. WASHERS WITH A 1-9/32" THREAD PENETRATION INTO SEASONED DRY WOOD SUPPORTING STRUCTURE. 2. PROVIDE QUANTITY OF LAG SCREWS AS REQUIRED TO MAINTAIN MAXIMUM SPACING AS SHOWN IN TABLE WITH A MINIMUM OF THREE (3) LAG SCREWS PER JAMB. LAG SCREWS AT TOP AND BOTTOM OF JAMB SHALL BE PLACED A MAXIMUM OF 6" FROM THE END OF THE JAMB. 3. LOAD PER JAMB CALCULATED BY TAKING DESIGN LOAD (PSF) TIMES DOOR WIDTH (FT) DIVIDED BY 2. EXAMPLE: DESIGN LOAD = 30psf DOOR WIDTH =16ft LOAD PER JAMB = 30psf x 16ft/2 = 240lb/ft 4. CHART IS BASED ON 6'-6" MINIMUM AND 24'-0" MAXIMUM DOOR HEIGHT. 5. DOOR JAMB TO BE 2x6 NO. 2 GRADE SPF LUMBER OR BETTER MOUNTED DIRECTLY TO SUPPORT STRUCTURE. 6. DESIGN OF THE SUPPORT STRUCTURE SHALL BE THE SOLE RESPONSIBILITY OF THE BUILDING DESIGNER AND SHALL BE DESIGNED FOR THE JAMB LOAD LISTED IN ABOVE TABLE AS CALCULATED PER NOTE 3. 7. MINIMUM EDGE DISTANCE SHALL BE 1-1/2" AND HOLES SHALL BE PRE -DRILLED TO PREVENT SPLITTING. 8. CALCULATIONS CONFORM TO ANSI/AF&PA NDS-2005. 9. LAG SCREWS SHALL CONFORM TO ANSI / ASME STANDARD 1318.2.1. Approved Mark R. Barrow, PE Florida License No. 57389 Wayne Dalton Corp. 3395 Addison Drive Pensacola, FL 32514 Revision P8 REVISIONS IL Wagne Balton 3395 ADDISON DRIVE PENSACOLA, FLORIDA 32514 (850) 474-9890 MARK R. BARROW, PE FLORIDA LICENSE NO. 57389 SEE DETAILS 1, 2. AND 3 REQUIRED FOR VERTICAL POST REINFORCING 1 SYSTEMS. 6" MA; M1 SF 6" MA MINIMUM 2x6 #3 rk HEADER LOCK SOUTHERN PINE BRACKET LUMBER. 4" 4" 2-3/4" (2) 3/8" SIMPSON TITEN HD SCREW ANCHOR WITH A 1 1/4" WASHER AND A MINIMUM EMBEDMENT DEPTH OF 2-3/4" AND A MINIMUM EDGE DISTANCE OF 2-3/4". DETAIL 1 MINIMUM 2000 PSI CONCRETE NOTE, MAXIMUM DESIGN LOAD CAPACITY OF 2085 LBS. DOOR WIDTH - MINIMUM 2x6 g3 CL HEADER LOCK SOUTHERN PINE BRACKET LUMBER. 4" (4) 3/8" SIMPSON TITEN HD SCREW ANCHOR WITH A 1-1/4" WASHER AND A MINIMUM EMBEDMENT DEPTH OF 2-3/4" AND A MINIMUM EDGE DISTANCE OF 4". DETAIL 2 MINIMUM 2000 P51 GROUT FILLED CMU NOTE, MAXIMUM DESIGN LOAD CAPACITY OF 2400 LBS. MINIMUM 2x6 #3 rL HEADER LOCK SOUTHERN PINE BRACKET LUMBER. 4" 4• -1/2" 1-1/2" 1 (4) 3/8" DIA. LAG SCREWS WITH 1-1/4" O.D. WASHERS. LAG SCREWS SHALL HAVE A MINIMUM PENETRATION OF 1-9/32" INTO THE MAIN SUPPORT MEMBER. T I WOOD SUPPORT STRUCTURE NOTE` MAXIMUM DESIGN LOAD DATE CAPACITY OF 2430 LBS. „o.,,,,, c /1. it CHECKED 5/24/07 1 MRB DRAWING PART NO. rREV..JAMB CONNECTION SUPPLEMENT 324620