Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSDATE: 1(0h r 1 PERMIT NUMBER. ✓ I U V1 ' �O, t-j ° -1 PLANNING & DEVELOPMENT SERVICES DEPARTMENT o BUILDING & CODE REGULATIONS DIVISION 11UQ 2300 Virginia Avenue x Fort Pierce, FL 34982 SCANNED (772) 462-1553 BY APPLICATION FOR REPLACEMENT OF St. Lucie County WINDOWS, SKY1LIGHTS, DOORS & OVERHEAD GARAGE DOORS 1. LOCATION/SITE ADDRESS: R M iTz Wwk. 7e NS F /U i3fi9 - N rL 34 5 S7 2. PARCEL ID NUMBER: ` 5'j) - 503 - 0 0;M - 0 Cad - ° 3. DESCRIPTION OF PROJECTOR WORK ACTIVITY: TN STA LC.. d- j M Pi4 C.7- —DOOt;Z 4. TYPE OF STRUCTURE: SIR 5. OWNERS INFORMATION MOBILE HOME OTHER Name: WA LT&Z 9 M A2THA ?AUL. Address: 1 I (O RE p ag LM City: SINS&M BJAC14 State: Fi. zip: 39 � 51 Phone: 6. CONTRACTOR'S INFORMATION FL Reg/Cert #: County Cert #: a(pg® I Business Name: PIC)NEEa Phone Number: Windows, Swing Doors, Skylights, Fixed Glass Opening Design Pressure A.S.C.E - 7 Design Pressure Product Manufacture Model # Method of Attachment # Florida Product Approval # 120 mph 1130 mph L4o mph T. M . Windou • o a Windows & Skylights Exposure B — Exposure C 1 190 -ti 4 Overhead Garage Doors < 30' - F.B.C. Table 1609.6 (1) + 1609.6 (2) B- Size C- Size Ob 7. VALUE OF CONSTRUCTION: $ 1 , 00 FEES DUE: RECEIPT: OWNERS AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in compliance with all applicable laws regulating construction and zoning. YAIC4kAkk— C4 PRINT QUALIFIERS/OWNERS NAME A OF ER/OWNER STATE OF FLORIDA, COUNTY OF �PiLM�Q1��,►T ACKNOWLEDGED BEFORE ME THIS �(j DAY OF 20 i BY fS U t� L CLAtM WHO IS PERSONALLY KNOWN TO ME OR WHO HAS PRODUCED AS IDENTIFICATION SIGNAT F NOTARY TITLE: NOTARY PUBLIC TYPE OR PRINT NAME OF NOTARY COMMISSION NUMBER NOTICE TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY,,o � IN YO,WXfly4 G Notary Public - State o1 Florida My Comm. Expires Feb 23, 2015 Commission # EE 67219 ST. LUCIE COUNTY Vinyl Siding TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT [] Attach 2 copies of the NOA or Florida approval with details to the product being used. INSTRUCTIONS Please complete all information in the space provided. All information must be Printed (use black or blue ink only) or Typed. This application for replacement of Windows, Skylights, Doors & Overhead doors to be used for only those activities that are not otherwise included under a primary building permit. This application for Permit may not be used for any activity that includes any type or kind of structural alteration. Building activities involving structural alteration, in addition to the replacement of Windows, Skylights, Doors & Overhead doors, must be permitted through the regular building permit review process. The information to be provided with this application includes: 1. LOCATION/SITE ADDRESS: ............................................. Indicate the street address, or general location, of the property on which the building activity is taking place. 2. PARCEL ID NUMBER........................................................ Indicate the Property Tax Identification Number for the property on which the building activity is taking place. 3. DESCRIPTION OF PROJECT OR WORK ACTIVITY........ Briefly describe the building activity under permit application. 4. OWNERS INFORMATION: ................................................. Indicate the name and address of the owner of the property on which the product is to be installed. 5. CONTRACTORS INFORMATION: .................................... Indicate the State of Florida (if applicable) and St. Lucie County contractors registration numbers, and the name of the business doing the work. 6. VALUE OF CONSTRUCTION :........................................... Indicate the total value of the work to take place. Total cost of construction includes all material and labor costs associated with the building/construction activity. The value of construction is used to determine the amount of permitting fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction. All applications for Permits are to be submitted to the St. Lucie County Building and Zoning Department, St. Lucie County Administration Building, 2300 Virginia Avenue, Fort Pierce, FL 34982. All applications for Permits must be complete and filed with the Department no later 4:30 P.M. each business day. No applications will be accepted for processing after 4:30 P.M. For assistance in completing this application, please contact the St. Lucie County Building and Zoning Department, at (772) 462-1553, during regular office hours (8:00 AM - 5:00 PM), Monday through Friday. Following the issuance of this Windows, Skylights, Doors & Overhead doors replacement Permit, the scheduling of all required inspections maybe made by calling (772) 462-1261. SLCCDV FORM NO: 006-05 PLANNING & DEVELOPMENT SERVICES DEPARTMENT BUILDING & CODE REGULATIONS DIVISION 2300 Virginia Avenue Fort Pierce, FL 34982 772-462-1553 APPLICATION FOR STORM SHUTTER PERMIT DATE: T1 I I PERMIT NUMBER: 1. LOCATION/SITE ADDRESS: lI(p T-le.Ped-fz, LANs Tems&'J 6EACA I-L, 3g95_7 J. 2. PARCEL ID NUMBER: y 511 - SD 3 - nay - Q oo - 9 SECT I I TWP I I RNG I I MAP I I ZNG I I LU I I MIT 3. DESCRIPTION OF PROJECTOR WORK ACTIVITY: :rNsrl4 u_ 2 tZO L. LUP H UIVZ1 CAN f- SHUTT-E& WITH W-SID4 CIZANX., 4. TYPE OF STRUCTURE: SFR ADDITION OTHER 5. OWNER INFORMATION 6. CONTRACTOR INFORMATION Name: WAL.TER f AIZT14A'PAUL Address: _ I 1 (0 'Pap Pa (2 LN City: 16N )SElu HEAL} State: rL. Zip:3yg5`1 Phone: C-7'7a, aA9_ aa5'(0 FL Reg/Cert #: County Cert #: a 3$ G 77 Business Name: 't p N E 8 . hu aiz i ccw ?tzc)- Phone number: S* % `I`i' 3 5`? _aCT1 O Type of Surface attachment: Wood Frame Concrete ✓ Masonry Other Product Type Maximum Opening Pressure per A.S.C.E. 7 Product Compliance Report # Method of Attachment As per Product Approval or Engineers Anal sis 120 mph 130 mph 140 mph 140 Exp. C FL N.O.A. Other Anchor Type Anchor Spacing Removable Panels Accordion Roll Up Lj(:09_Rj 91 01 1 i1LjA,3`kj—%-pcCA 8 .vNcl Q.zs Colonials Other ALL PRODUCTS SHALL BE LABELED FOR DETERMINING IMPACT RESISTANCE FROM WIND BORNE DEBRIS. * *SEE FINAL INSPECTION PROCEDURE FOR EXISTING RESIDENTIAL STRUCTURES ONBACK //� 7. VALUE OF CONSTRUCTION: $ l9 00Od FEES DUE: OWNER'S AFFIDAvrr: I certify that all of the information contained in this application is correct and that all work will be done in compliance with all applicable laws regulating construction and zoning. A C_I4A & L. C h A re Ctl -Mdl 4"_' PRINT NAME OF OWNER OR CONTRACTOR/QUALIFIER SIGN O CONTRACTOR/QUALIFIER STATE OF FLORIDA, COUNTY OF Pmug\ � EP► oA ACKNOWLEDGED BEFORE ME THIS (4h DAY OF m A4 , 20 I ( BY, M I CA AE L. CLA N C.y WHO IS PERSONALLY KNOWN TOME OR WHO HAS PRODUCED 1M a,`0, o,c!;p SIGNATURE OTARY TITLE: NOTARY PUBLIC AS IDENTIFICATION. I(Y AMN ` A V—AL& TYPE OR PRINT NAME OF NOTARY SEAL COMMISSION NUMBER r E' G_IA q — ,�t'pY AVeM �, MARY TAKACS SLCPDSD Revised 96/17/2010 ?� *?Notary Public - State of Florida My Comm. Expires Feb 23. 2015 Commission #EE 1i7219 NOTICE TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. INSTRUCTIONS Please complete all information in the space provided. All information must be Printed (use black or blue ink only) or Typed. This application for Shutters to be used for only those activities that is not otherwise included under a primary building permit. This application for Permit may not be used for any activity that includes any type or kind of structural alteration. Building activities involving structural alteration, in addition to the installation of Shutters, must be permitted through the regular building permit review process. The information to be provided with this application includes: 1. LOCATION/SITE ADDRESS: .............................................. Indicate the street address, or general location, of the property on which the building activity is taking place. 2. PARCEL ID NUMBER........................................................ Indicate the Property Tax Identification Number for the property on which the building activity is taking place. 3. DESCRIPTION OF PROJECT OR WORK ACTIVITY........ Briefly describe the building activity under permit application. 4. OWNERS INFORMATION: ................................................. Indicate the name and address of the owner of the property on which the product is to be installed. 5. CONTRACTORS INFORMATION: .................................... Indicate the State of Florida (if applicable) and St. Lucie County contractor's registration numbers, and the name of the business doing the work. 6. VALUE OF CONSTRUCTION: ........................................... Indicate the total value of the work to take place. Total cost of construction includes all material and labor costs associated with the building/construction activity. The value of construction is used to determine the amount of permitting fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction. All applications for the installation of Shutters are to be submitted to the St. Lucie County Building and Zoning Department, St. Lucie County Administration Building, 2300 Virginia Avenue, Fort Pierce, FL 34982. All applications for Permits must be complete and filed with the Department no later 4:30 P.M. each business day. No applications will be accepted for processing after 4:30 P.M. For assistance in completing this application, please contact the St. Lucie County Building and Zoning Department, at (772) 462-1553, during regular office hours (8:00 AM - 5:00 PM), Monday through Friday. Following the issuance of this Shutter Permit, the scheduling of all required inspections may be made by calling (772) 462-1261. INSPECTIONS ** EXISTING RESIDENCES All shutters must be installed and in place at the time of the final inspection, except for Egress Windows and Doors where one panel must be installed and the remainder must be by the opening for the inspector,to verify remaining panels. ON NEW HOMES ALL SHUTTER PANELS MUST BE INSTALLED AT TIME OF FINAL INSPECTION OR INSPECTION WILL FAIL AND C.O. WILL NOT BE ISSUED. SLCCDV FORM NO: 006-05 .. �. �.... vrvv. acr.lr 51 LU AL LTJ PAGE 05 Public Works department Code Compliance Division 2300 Virginia ,Avenue Ft. Plerae, FL 34%2-un PJ C .A F1D RE: Pormit 9- ff QO. incensed as a Contraclo (Plaaec prlta same and dircic lictnaa type) 11gitLea-r/�11Cchf teed ldtng SVkiC rt* Geti"A Building, Rasldentlal/ or Rooting Conlraotar or any ln'dtvldusl aottitled under 468 1?_S, to malts truth an showntZon, All affidAvl; s myst include photograp}tr of each pions of the roof with the per�nir # or sctdroas d otcarl shown 1 talked on the deck fcr aaA inspcelion, y On or about lr < eta & limo) / �' .• did persoinally inspect the " e r ' 'work at fetrc/a one) r or ,,w (Job Site Address) $aced Upon that $xtiminatiu>, I have determined the insta'Iltdon was dope acaurdinto tho Hunde ne Mitigations Petrof't,lvtatival (Based on, 553,844 F.S.) � ignature & Seal STATE OF FLORIDA COUNTY OFLl� l3 License # '� Sworn to and subscribed before me this 4 48Y of 01s personally known or who has produced by >es Ideptlticdtion, . Notary Public, Btato ofpiorida . Signature 9ENotary; COMM138144 No.! ,uN � 3 pit om19/27/07 �, ,•,Sic WorKs 1 Notary Public State of Florida ^ Denise L®may "s. c� - � tvty Commission b>)853H48 �'o; 4�°� Erp6res o3123�'2013 �'•V�ts�Ra`�ti"4rilyr wi°;�ht'S.o�;RirN��tP l 'd 6000'ON 0NId00d I ladvo WHOO:II 110Z 'Nl unr t 1V11'tu"--1-lau0 %-VUJ-LLY - "Unuiny, %-VUG \iVL"F1JLa11VG Vl.L1LU a 1 ar,%, 1 VL G Building Code Compliance Office Prodtict Information Product Control Search Results QUERY PARAMETERS File Classification: Unknown / Unselected Applicant: T.M. Window & Door LLC Category: None Subcategory: None Material: None Impact Rate: None Maximum Design Pressure 0.00 N , : Maximum Design Pressure 0.00 0: Text Size: Res( NOA APPLICANT CATEGORY SUBCATEGORY IDESCRIPTION IMPACT MDP+ MDP- CLASS_DESC. Series "230" Outswing Large and 06-0327.02 T.M. Window & Doors Swinging Aluminum Aluminum Door Small Missile 90 90 High velocity hurricane zone Door LLC hvo Sidelites- Impact LMI Series 350 06-1016.01 T.M. Window & Doors Unknown / Unselected Unknown / Unselected Aluminum Sliding Glass [ None ] 0 0 High velocity hurricane zone Door LLC Door - Non Impact Series 605 Single Hung Large and 07-0402.04 T.M. Window & Windows Double Hung - Single Hung Aluminum Aluminum Small Missile 80 115 High velocity hurricane zone Door LLC Window Impact. (reinforced) Series "747 High Large and o7-osl2.os T.M. Window & Windows Double Hung - Single Hung Aluminum Performance" Aluminum Small Missile 90 130 High velocity hurricane zone Door LLC Single Hung Impact Window - L.M.I. Series 747 HP 07-0913.05 T.M. Window & Wndows Double Hung - Single Hung Aluminum Aluminum Single Hung Small Missile Impact 90 160 High velocity hurricane zone Door LLC Window - S.M.I. Series 350 Aluminum 07-1oos.o3 T.M. Window & Doors Sliding Aluminum Sliding Glass Door [ None ] 100 120 High velocity Door LLC w/ hurricane zone reinforcement- L.M.I. Series 230 07-1010.21 T o. Window & li:] Swinging Aluminum Outswing luminum Door Small Missile EE High velocity Impact hurricane zone / wo Sidelite Series 350 E-1126-01 T o. Wic ow & Doors Sliding Aluminum Aluminum Sliding Glass Small Missile Impact 100 210 High velocity hurricane zone Door http://www.miamidade.gov/buildingcode/pc-result app.asp?fldNOA=&Classification=0%2CUnknown+... 12/15/2009 Series "515" Outswing Large and 08-0506.11 T.M. Window & Windows Casement Aluminum Aluminum Small Missile 80 80 High velocity hurricane zone Door LLC Casement Impact Window - L.M.I. Series 350 Aluminum Large and 08-0617.03 T.M. Window & Doors Sliding Aluminum Sliding Glass Door w/ Small Missile 100 120 High velocity hurricane zone Door LLC reinforcement- Impact L.M.I. Large and 08-0917.08 T.M. Window & Windows Fixed Aluminum Series 338 Aluminum Fixed Window -L.M.I. Small Missile 95 140 High velocity hurricane zone Door LLC Impact Series 805 Aluminum Large and 09-0105.02 T.M. Window & Windows Horizontal Slider Aluminum Horizontal Rolling Window Small Missile 90 130 High velocity hurricane zone poor LLC - L.M.I. Impact Series "370 " Aluminum Large and 09-0319.06 T.M. Window & DOOfS Sliding Aluminum Sliding Glass Door Small Missile 72 72 High velocity hurricane Door LLC w/ zone Reinforcements- Impact Impact Series 605 Single Hung Large and 09-0604.24 T.M. Window & Windows Double Hung - Single Hung Aluminum Aluminum Window Small Missile 80 115 High velocity hurricane zone Door LLC (reinforced) Impact Series "230" 8'0" Outswing 09-0622.03 T.M. Window & Doors Swinging g g Aluminum Aluminum French Doors w/ None � 1 80 175.4 High velocity. hurricane zone Door LLC Sidelites (Reinforced) - N.I.IL Revs 15 Home I Privacy Statement I Disclaimer I Using Our Site I About Us I Phone Directory I Contact Us MILA M.F DE © 2009 Miami -Dade County. All rights reserved. http://www.miamidade.gov/buildingcode/pc-result app.asp?fldNOA=&Classification=0%2CUnknown+... 12/15/2009 MIAM WMIM MIAMI-DADE COUNTY, FLORIDA METRO-DADE FLAGLER BUILDING BUQ.DING CODE COMPLIANCE OFFICE (BCCO) 140 WEST FLAGLER STREET, SUITE 1603 PRODUCT CONTROL DIVISION MIAMI, FLORIDA 33130-1563 (305) 375-2901 FAX (305) 375-2908 NOTICE OF ACCEPTANCE (NOA) www.buildingcodeonline.com T. M. Windows & Door, LLC - 601 N. W.12`" Ave., Pompano Beach, Fl. 33069 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Series "230 " Outswing Aluminum Door w / wo sidelites APPROVAL DOCUMENT: Drawing No. W02-77., titled "230 Alum Outswing Door w/sidelites. ", sheets 1 through 6 of 6, prepared by AI-Farooq Corporation, dated 08-28-02 and last revised on Apr 24,2008, signed and sealed by Dr. Humayoun Farooq, P. E., bearing the Miami -Dade County Product Control Renewal stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Division. MISSILE IMPACT RATING: Large Missile Impact Resistant Limitation: Exterior (positive) design loads to be limited per sheet 2 of the drawings. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises & renews NOA # 02-1016.09 and consists of this page 1 & evidence page E-1 & E-2, as well as approval document mentioned above. The submitted documentation was reviewed by Ishaq L Chanda, P. E. APPROVED 4z0(t NOA No 06-0327.02 Expiration Date: December 26, 2012 Approval Date: July 17, 2008 Page 1 T. M. Windows & Door. LLC NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS (Transferred from file # 02-1016.09) 1. Manufacturer's die drawings and sections. 2. Drawing No. W02-77., titled "230 Alum Outswing Door w/ sidelites. ", sheets 1 through 6 of 6, prepared by Al-Farooq Corporation, dated 08-28-02 and last revised on Apr 24,2008, signed and sealed by Dr. Humayoun Farooq, P. E. B. TESTS 1. Test report on 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Forced Entry Test per FBC, TAS 202-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411 3.2.1 and TAS 202-94 along with marked -up drawings and installation diagram of aluminum outswing door, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-5458, dated 02/15/08, signed and sealed by Carlos S. Rionda, P.E. 2. Test report on 1) Air Infiltration Test, per FBC, TAS 262-94 2) Uniform Static Air Pressure Test, Loading per TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Forced Entry Test per FBC, TAS 202-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411 3.2.1 and TAS 202-94 along with marked -up drawings and installation diagram of aluminum outswing door, prepared by Fenestration Testing Laboratory, Inc., 3355, dated 01/29/02 and FTL-3355, dated 01/29/02, signed and sealed by Luis Figueredo, P.E. and Aldo P. Gonzales, P.E. , respectively, (transferred from file # 02-1016.09) 3. Referenced test report per TAS 202-94, Test Report No. FTL-2648, dtd 06/06/00 issued by Fenestration Test Lab, signed & sealed by Aldo P. Gonzales, P.E. C. CALCULATIONS 1. Structural performance, comparative analysis and anchor verification calculations dated Apr 24, 2008, prepared by Al- Farooq Corporation, signed and sealed by Dr. Humayoun Farooq, P.E. 2. Glazing complies w/ ASTM E-2002. D. QUALITY ASSURANCE 1. Miami Dade Building Code Compliance Office (BCCO). Ishaq I. Chanda, P. E. Product Control Examiner NOA No 06-0327.03 Expiration Date: December 26, 2012 Approval Date: July 17, 2008 E-1 T. M. Windows & Door. LLC NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 06-0216.06 issued to Solutia Inc. for "Saflex IIIG interlayer", expiring on 03/04/09. 2. Notice of Acceptance No. 07-1116.11 issued to Saf-Glas, LLC for "SAF-GLAS, polycarbonate laminate", expiring on 12/16/12. F. STATEMENTS 1. Letter of conformance and "No financial interest, dated 03-08-2008 signed & sealed by Dr. Humayoun Farooq, P.E. 2 Statement letter of compliance, as part of above test report. G. OTHER 1. This NOA revises & renews NOA # 02-1016.09, expired December 26, 2007. 2. Test proposal # 07-3698 dated Nov 08, 2007, issued by BCCO. ishaq I. Chanda, P. E. Product Control Examiner NOA No 06-0327.03 Expiration Date; December 26, 2012 Approval Date: July 17, 2008 E-2 149 3, FRAME 1 SURFACE APPLIED FALSE MUNDNS MAY BE USED 3' 11' 3' f'� e' I�- ANCHORS AT MTG. STILE ENDS (4) REDD. FOR WOOD INSTALLATIONS (T REQD. FOR CDNC. INSTALLATIONS 13' MAX. S' HEAD/SILL HEA C01 1 II E II 11 ii F n II II / /ii p n II \ II LocK` oPnoN ,�1 II II a yy11 II Ni/. ----- II \ Ilk Al/i 31011 / Ili. ------ II II II II II \ II \II jl II / I� jj II u II IN -A JIVE II\ AC) VE / II II l I I I 33 3/e 25 1/2' I 25 1/2' II 1 1 33 3/8' D.L. OM D.L OPG. D.L. OPG. I D.OPG. .- ANCHORS AT MTO. STILE ENDS (4) REOD. FOR WOOD INSTALLATIONS (2) REQD. FOR CONC. INSTN1A710NS 71 5/8• SURFACE APPLIED FALSE MUNTINS MAY BE USED n n ro n W �4 o 1 1/4' I FANM WIUM I_ 34 1/r PANEL V& 1 1/4- 37 5/8• 71 5X 37 S/e' 51DEUTE WIDTH DOOR FRAME WIDTH SIDELITE WIDTH ( OXXO ) TYPICAL ELF iSERIES-230 ALUM DTJT-SWING DOOR w- SIDELTTES230�UMOL��G DOO�W�smumS DOORS/SIDEIJTES GLAZED WITH LAMINATED GLASS RATED FOR LARGE MISSILE IMPACT AND REQUIRE NO SHUTTERS. HIGH VELOCITY HURRICANE ZONE (HWZ). WOOD BUCKS Ely OTHERS, MUST BE ANCHORED PROPERLY TO TRANSFER LOADS TO THE STRUCTURE ANCHORS SHALL BE AS LISTED, SPACED AS SHOWN ON DETAILS, ANCHORS EMBEDMENT TO ala MATEFW SKULL BE BEYOND WALL DRESSING OR SNCCO. ANCHORING OR LOADING CONDITIONS NOT SHOWN IN THESE DETAILS ARE NOT PART OF THIS APPROVAL A LOAD DURATION INCREASE IN ALLOWABLE STRESS IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. MATERIALS INCLUDING BUT NOT LIMITED TO STMIMETAL SM M'S, THAT COME INIO CONTACT H OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OWIT F 2004 FLORIDA BLDG. CODE SECTION 2003.8.4. FRAME WIDTH MAX. C-- HEAD � 1 1 I I IY \I Il� It II I LocIlI / --11-U----- I - N I IN-Ai\tI4Irn�� i"'"- j ACT+VE SEE SHEET 2 FOR GLASS TYPES AND DESIGN LOAD CAPACITIES. 5' MAX. SEE SHEET 2 FOR GLASS TYPES AND DESIGN LOAD CAPACITIES. 5' MAX. N Z 0 3 HEAD/SILL CORNERS n cy w O sm� I b Z�Z � Q¢ U 3�m _ s ,or 28 5/8' 28 5/8' �1, Z a - D.L. OPG. D.L OPG. ivy o� 34 1/2' 8�� PANEL WIDTH 34 1/f r /- n-0�--�-F� PANEL WIDTH I II 11 I I I I ( XX)� th neda. c tl 8 -ft-'i 2 Oz CIE INo t►ndutf7 rd o - ryry. LAMINATED GLASS LARGE MISSILE IMPACT 4 Iini657� droving no. loon W02-77 sheet 1 of g DESIGN LOAD CAPACRLES - PSF FOR SIZES SHOWN BELOW OR SMALLER GLASS GLASS TYPE 'B' EXT. (+) INT. (-) EXT. (+) INT. (-) DOORS I ES I.- /0 OMDOORS 80.0 90.0 90.0 90.0 SIDEURES 80.0 90.0ITH - FOR INSTALLATIONS WHERE WATER INFILTRATION RESISTANCE IS REQUIRED LIMIT EXTERIOR(+) LOADS AS FOLLOWS 1-5/8' THRESHOLD +53.3 PSF 2-5/8' THRESHOLD +80.0 PSF 3-1/2' THRESHOLD +90.0 PSF NOTE: GLASS CAPACITIES ON THIS SHEET ARE BASED ON ASTM E1300-02/04 (3 SEC. GUSTS) AND FLORIDA BUILDING COMMISSION DECLARATORY STATEMENT DCA05-DEC-219 �377 7/16' 76 1/4• LNX. 115 3/16• MAX.MAX 115' MAX. I I (x) (xo) (oxo) (xox) (ox) 71 s/s' MAX. 1101/2• MAX. 146 3/g• MAX. _ \ / (xx) (xxo) (oxxo) (oxx) APPROVED CONFIGURATIONS 3/16' HEAT STREN'D GLASS 090 SAFLFX MG NEEPSAFE MAXIMUM ►VB INTERIAYFR 3/16' HEAT STREN'0 GLASS SILICONE TRl7AC0 1REMGUZE 500 GE RGS7700 a I 1V 0.460' OVERALL LAM. GLASS GLASS TYPE 'A' (SWELITE) HEAT STREN'D CLASS 1 SAFLEX IIIG KEEPSAFE MAXIMUM INTERLAYER -3/16' HEAT STREN'D CLASS SLCONE TREMCO TREMGLAZE 500 GE ROS7700 M n C F � 0 jc�M o 1 ANNEALED GLASS ; m� K p 8 1 SAF—GIAS .YCARBONATE LAMINATE 0 4 -3/16' ANNEALED CLASS SNCONE ' 0 Q= N TREMCO TREMGLAZE 500 GE RGS7700 3 1 m 8^0 0. 3I a000 0.4607 OVERALL LAM. GLASS 0.455' OVERALL LAM. CLAW _GLASS TYPE 'A' GLASS TYPE 'B' (DOOR LEAD (DOOR LEAF) GLAZING OPTIONS 179L10CERENEWFD "mains rvaA Ihr P-I fp A. JRMEG 7' 53a drawing no. 2008 1 w02=77 /B' x 31W WEEPS .1/4• FROM SILL ENDS SPACING HOOD BUCKS AND METAL STRUCTURES NOT BY TM WINDOWS MUST SUPPORT LOADS IMPOSED BY GLAZING SYSTEM AND TRANSFER THEM TO THE BUILDING STRUCTURE TYPICAL ANCHORS: SEE ELEV. FOR SPACING 1/4' DIA TAPCONS BY ELCO NTO WOOD STRUCTURE 1-3/4' MIN. PENETRATION INTO WOOD 'HRU 1BY OR 213Y WOOD BUCKS INTO MASONRY OR CONC. —1/4' MIN. EMBED INTO MASONRY OR CONC. NIRECTLY INTO CONCRETE OR MASONRY —1/4' MIN. EMBED INTO CONCRETE OR MASONRY '/4' SELF DRILLING SCREWS (GRADE 6 CRS1 NTO METAL STRUCTURES STEEL : 12 GA. MIN. (Fy . 36 KSI MIN.) 1LUMINUM : 1/8' THK. MIN. (6063-TS MIN.) STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) IYPICAL EDGE DISTANCE NTO CONCRETE AND MASONRY - 2-1/2' MIN. NTO WOOD STRUCTURE o 1' MIN. NTO METAL STRUCTURE - 3/4' MIN. 3/0' O ALT. 8 3 ROWS REDD. FOR ESIGN LOADS ABOVE +80.0 PSF b SMS AT tY O.C. n • SEE EST DIE EUW. FOR SPACING •t g STURIIC UM RA PE // 7 CAR 363t1 CRODUCT RENEWED �wlth the Flo"ask ^ . M �doxDm ^OSZ .D 8 8 ACRNG b F droning no. . � 2ooR t>rer�. wo2-77 sheet 3of 6 FLUSH FLUSH AT INACi1VE IFAF ff AAMIYEE LEAF V � I N mF 1/4' MAX. SHIM 34 1/4' SELF DRILLING SCREWS AT 4-1/2' FROM ENDS AND 17-1/2' O.C. F al Ir 3 O O 31 © O 2 NOT REDD. 1p FOR 6 0 RS 3, IN -ACTIVE LEAF µ•NEB Pd mDOOe0 PSF 1 ACTIVE LEAF OR LESS S 21 12 4 0 Q OPTWNAL 1a B LEAF WIDTH 1 1/4' LEAF WIDTH 1 1/4' MINCE ASSEMBLY LOCK #I SWELITE WIDTH DOOR FRAME WIDTH SIDELITE WIDTH ^ OVERALL FRAME WM @Q oc Q 1° O TYPICAL ANCHORS EXTERIORSEE $ O EM. FOR SPACING 3 3 p3 eV_ 8 • m �`° IN-ecrtvs LEAF ACTIVE LEAF � --OIL - - jABM 31 SEEION I2 TYPICAL ANCHORS u SEE ELEV. FOR SPACING METAL ° . 1/4' MAX.STRlIC1URE 1/4' YAX. SHIM SPACE SFOM O K O c o m°a • ACTIVE LEAP TEE EL ANCHORS SEE ELEV. FOR SPACING MDLTCFRENEWED ° � < m the F1erTda ' fY Cade • L • SiRMURES CPE Aeaptuee No - b AN.'3a3a5 44r �� MIN. ,• }ZjS S drowinq no. LEAF WIDTHLEAF WIDTH I d 4 2008 FRAME WIDTH FRAME TH W02-77 sheet 4ot f3 I �3000--{ 1LT44 I•� o6e SI20 L773 1'iD0 I.594 I.525 LL J� Ib48 �JI. L600 FRAME HEAD FLUSH BOLT GUIDE TM-OJ8 GW-27646 -2123 2J2s L012 e F 3.43 3 000 L •062 L8 L8,3 LS00 II L500-i OSIDELTE FRAME DOOR JAMB Ij--GW 38�5jI72 O TM175 LS7 I .7so yy�� .625 81 WEATHER-STRIP ADAPTER amo 44 GW-31826 � 8 Abe I 37 2J25 CW 37888 .572 CENTER HINGE 325 7248�/E 0.5GW 37889-A OUTER HINGE HIN�­ 3 x 5/8' HINGE CAP SMS /10 X 5/6' r F.H. S. n I 7.E89 o I g 675 I in 1 '3� .415 II 2126 1+ 1— L730_j —� DOOR TOP & BOTTOM RAIL ,280 TM 081 HINGE ASSEMBLY 4.753 DECORATIVE MOULDING a000 GW-36737 A62 S23 .062 r.500 1.000 2A40 .750 L750 h-.062 L750 .750 .183 —I III ILI I L000 1A00p _T L r -1 F-.332 F--3.186--1 A62 "a- �4060� ® DECORATIVE MOULDING DOOR HINGE STILE TM-155A GW-36935 SILL ADAPTERS r r L43 640 b0O .625 7 1-740jFm622.500 O4s F_.429 TI . �- .625�3.009�1� GLASS STOP STD, FRAME SILL ALT. FRAME SILL GW-31956 GW-28615 O CW-J7319 DOOR LEAF STILE ALT. DOOR LEAF STILE' O GW 36048 0 TM172 .500�1 F- 3.790 .062 I I� 5 -[am 9r ' WYOUN .640�--�{ - 2,595 F � RUCt 16687 25 I I L534 L054 .�11I L � .629 I �---LB,9� .�3AD0—�1 .125 A iy 4 2np ALT. FRAME SILL I O LOCK STILE REINFORCEMENT TM-184 31 TM-075 TERM / PART 0 QUANTITY DESCRUPnON MATERIAL MANP./SUPPLIER/RRKMARKS I FRAME HEAD 0o63-T6 - GW 28615 1 FRAME BILL 5053-T6 - GW 37319 1 ALT. FRAME SILL kTM-38A TM184 1 ALT. FRAME SIL 5053-T5 - GW 35572 2 sonnE RWJE 6063-T6 - TM175 2 DOOR JAMB 6053-TB - GW 36048 1 PANEL LOCK STILE 6083-T5 TM172 1 ALT. PANEL LOCK STILE 8083-TO - 5 GW 36M 1 PANEL HINGE STILE 6063-75 - 5 TM-081 2 PANEL TOP/BOTTOM ROLL 6063-75 - 7 GW 31626 4 WFATHEASR6P ADAPTER 60B3-TS END OF DOOR STILES (TOP/BDTTOM) 6 GW 37689A 2/HINGE ASSY. TY OUTER BUR HINGE 6063-T6 DOOR PANEL/FRAME HINGE SIDE 9 GW 3=3 1/HINGE ASSY. TM CENTER BUTT HINGE 6063-T6 DOOR PANEL/FRAME HINGE SIDE 10 GW 32222 2 DOOR LOCK INSERT 6053-T5 LOCK STILE 11 - 2/ LEAF 3/4 ■ 1 1/4 a 3/4 v 1/8' THK. CAP ALUMINUM 3' LONG 12 - 2/LEAF TM FLUSH BOLT ASSEMBLY ALUMINUM DOOR LOCK STILES 111 4037 AS REWD. 'ULTRAFAB' CENTERFTN WOOLPILE WOOL LOCK STILES, JAMBS. HEAD, SILL 17 OW 27646 2/LEAF FLUSH9OLT GUIDE. 2' LONG W83-75 LOCK STILES ENDS (1DP/BOROM) 18 I/HINGE 7/32Y HINGE PIN STEEL AT EACH HINGE ASSEMBLY 20 - AS REGO. 010 X 1/2' F.M. UNDERCUT SMS. STEEL AT FLUSH BOLTS 21 - 2/LE1F 1/270 THREADED ROD, WASHER 3 NUr STEEL TOP/BOTTOM END RAILS 22 SERIES 400 1 KWIKSEr KHO9l.0CK - ACTIVE LEAF 23 SERIES 600 1 KNIKSET DEADBOIT - ACTIVE LEAF 24 - 2/HINGE ASSY. HINGE BUSHING PLASTIC HINGE ASSEMBLY 25 - 36 DUST PLUG (OPTIONAL) PLASTIC DOOR JAMB INSTALL SCREW HOLES 26 - AS REOD. 010 R 1' P.H. SM (ASSY. SCREW) STIA DOOR FRAME MEMSERS/MULL CUPS 27 - 2/HINCE ASSY. HINGE CAP PLASTIC HINGE ASSEMBLY 29 1 SILL ADAPTER (V X 1' X 1/16' TUBE) ALUM - 30 1 SILL ADAPTER (1/27 X 1' X 1/16' TUBE) ALUM - 31 TM-075 1 LOCK S11LE REINFORCEMENT 5063-T5 FULL LENGTH O DOOR LOCK STILES 34 7M-ow 2 MULLION 6083-T5 BETI6EEN DOOR/SIOE LIVE JAMBS 35 GW J19S8 4 GLASS STOP NW-75 SIDE LIVE GLAZING PERIMETER 37 GW J6737 OPfp1IN. O.C. DECORATIVE MOULDING 6p63-T5 DOOR PANEL. PERIMETER 37A TY-i55A OPTIONAL' O.C. DECORATIVE MOULDING OM-T8 DOOR PANEL PERIMETER 3.375--j-'IIE FL� .187 3.000 129 3.500 " XLj MULLION TM-054A m%mV Z $z9 P w n O lag 6�3�m ILZq�>4 Q WAS CF Florlik " H ' g n drawing no. W02-77 10 UK P71 WMA FRAME CORNERS AND GLAZING BEAD TO PANEL SEALED WITH WHITE COLORED SEALANT. SEAMS BETWEEN MULLION AND JAMBS SEALED WITH SILICONE. HINGES: 7-5/8' LONG ALUM BUTT HINGES, AT 11' FROM EACH END AND ONE AT MIDSPAN OF LEAF. STANDARD STEEL THROW BOLT LOCK, KEY OPERATED ON EXTERIOR AND THUMB TURN ON INTERIOR AT EACH ACTIVE LEAF LOCK STILE, 48' FROM BOTTOM CONVENTIONAL LOCKSET WITH KNOB, KEY OPERATED ON EXTERIOR AND THUMB TURN ON INTERIOR AT EACH ACTIVE LEAF LOCK STILE, 39-1/2' FROM BOTTOM MANUALLY OPERATED CONCEALED FLUSH BOLTS AT TOP k BOTTOM OF EACH LEAF LOCK STILE (4) AT UOUBLE(XX) DOORS, (2) AT SINGLE(X) DOORS OPTION i2 MULTI —POINT LOCK SYSTEM .WITH LEVER HANDLE LOCATED AT 34-1/2' FROM BOTTOM OF ACTIVE LEAF LOCK STILE FASTENED WITH (2) 012-28 X 2-1/4' OH MS METALLIC STRIKE PLATE AT 34-1/2' FROM BOTTOM OF INACTIVE LEAF LOCK STILE FASTENED WITH (3) JTO X 1/2' FH SMS MANUALLY OPERATED CONCEALED FLUSH BOLTS AT TOP & BOTTOM OF INACTIVE LEAF LOCK STILE OPERATORS AT 10-1 2' & 76-1/2' FROM BOTTOM FASTENED WITH (2) 8-32 X 1/2' FH MS (RIM BOLTS AT TOP R BOTTOM OF ACTIVE AND WIICTIVE LE1F8 TO BE ENGAGED DUI= PERIODS OF HURRCANE WAHONG) 03 RENEWED whb the Florida 4;u drawing no. W02-77 Martha and Walter Paul 116 Pepper Lane Jensen Beach, FI. 34957 O Martha and Walter Paul 116 Pepper Lane Jensen Beach; FI. 34957 1) 36.5 x 80.25 - -a- - __ - A BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats & Facts I Publications I iiw staff �� Product Approval ! =USER: Public User Product Approval Menu > Product or Application Search > Application List > Application. Detail FL # FL4609-R1 Application TYpe. Revision Code Version I( Application Status Approved Comments Archived. ^! Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email. Category Subcategory Roller Star USA 1460 SW 6th Ct. Bldg 1400 Pompano Beach, FL 33069 (954) 972-4772 ddhhcc@aol.com David Ceccofiglio ddhhcc@aol.com DAVID CECCOFIGLIO 6351 NW 28 WAY SUITE C FORT LAUDERDALE, FL 33309 (954) 972-4772 ddhhcc@aol.com David Ceccofiglio 6351 NW. 28th Way Suite C Fort Lauderdale, FL 33309 (954) 972-4772 ddhhcc@aol.com Shutters Roll -up http://www.floridabuilding.org/pr/pr app dtl,aspx?param=wGEVXQwtDgsapkb2gQg)3hGXFgPvCyFgO... 5/18/2009 Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date -- ---- -- - Validated By _.. ----------_ -- - - Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved of Products Evaluation Report from a Florida Register Florida Professional Engineer Evaluation Report - Hardcopy Receive Water A Tillit PE-44167 Underwriters Laboratories Inc. 12/31/2012 Jesus Gonzalez, PX. Validation Checklist - Hardcopy Recei% FL4609 R1 COI Certificate of Independei Standafd TAS 201, 203 TAS 202 Method 1 Option D 09/16/2008 10/07/2008 10/23/2008 12/10/2008 FL # iModel, Number or Name ' Description 4609.1 60mm and 40mm Roll -up Shutter Extruded aluminum slats interlo( HVHZ knuckles and retained to provide Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL4609 R1 II Drawing No 08- Approved for use outside HVHZ: Yes Verified By: Fenestration Testin Impact Resistant: Yes Created by Independent Third F Design Pressure: N/A. Evaluation Reports Other: Large Missile Impact Roll -up Shutter may be I FL4609 R1 AE Certificate of In installed within the "High Velocity Hurricane Zone". Wind FL4609 R1 AE Product Evaluai pressures and design as per drawing 05-138. When Created by Independent Third F shutters are engaged, the bar must be installed. http://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgsapkb2gCgBhG)OgPvCyFgO... - 5/18/2009 G09M M07M r. &aL-UP s+wrrin sHONN ON TT¢S mwwcr rmLtrA710N Domwwr (P.E.Da HAS BEEN itR = FOR cope cowu4mE IN ACCOROWC LAIN THE to¢7 ELYRDN OF THE FLORG4 BULOAo 000E 7M5 ROLL -UP SHUTTER MAY BE INSTALLED AT k M WILOGRY HURRKARE ZONES' M4N WW LOADS SHAtt BE DEIERMWED AS PER SECTION 1620 OF THE ABOVE MEMIONED COAT, N ORDER To WAFY RAF cOwmwfs AN o ANCIAGIRS OW im P.E:O. As rwo WERE Aor DYER STRESSED. A MX ANCREASE IN ALLOMKr STRESS FOR WWO UZADS WAS M USED IN THOR ANALYSIS, HOWEI?R A DMWON MOTOR CO.1.e0 WAS USED MR VERIPTCATON OF PLLSTENERs 2r WOOD. RaL-LM swunw-s AL$OMACY FOR amwr AHD FArmz RESLSTANCE ms BEET VER'FTED IN A000RA4t w WAN sECTON I&M of THE ABOVE MENTIONED =9 AS PER W-201, 20 k 203 PROTOCOLS PER FE,01RARON TESTING LAB REPORTS 14104 4rsa 4197, 41M 4104 42M 42OZ 424 4201 4204 4^ 42M 421 F. 404 421,6 42F4 4217. 4212; 4221, 4224 4224, 42A 4227, 4224 4229 423% 423Z 421% 42J4. 4254 42.1& 42J2 a 4M 2. ALL ALUI MW &MUSOW W L BE ALUU MN ASSOCM710N 6OM-Ttt ALLOY t MOM PAM QM WWSE HOTEO). i ALL SCREWS M BE STAINLESS SM JO4 OR 310 M57 SERIES OR COMM RE&ISIANT COATED CARBOY STEEL AS PER aN SOME W/ 30 Aar MTh. WELD STRENGTH AND 90 NX Wti TFJN= STRENGTH. ALL 7EK SCREWS PULL. BE AS MANUFAcnm or HrW BUCOLIC B1R 4. BOLrS To w ALLYRNUM ASSIOCAImN 2024-T4 ALLOY ! TEHPErb'AS7N A-07 r.4Lwaw STEEL OW AISI Jo4 SEm STAINLESS STEEL, MR JM hs Mkt w WED STRENGTH. 5. SIQ4M BW AT FLOOR AND CEXAM: LAOUNRNG WrAUAWNS MAY BE REMOVABLE AT NON MAWAW C10HOROft HOKl ER EACH STM AW SFWl BEAR A PERMCNENT LABEL. IN A WSLDLE PUCE WIN A MtRRIN'C NOTE 9&WC TM THE TETMNF OR OWNER THAT STOW BARS MUST BE RNSDNL ED WON CORRESPOAD09 HARM WRE OL/RDG PMT W OF HRIHM4NE NTHdNM AND rFMT ROLL. UP SHUTTERS WILL NOT OFFER Ht4VMNE PROTECRON NNLE` T ALL STORM BW ARE BNSTALLED AS COMM 6. REMOVABLE STORM BARS SHALL BE STORED IN A CONSFKSOUS PLACE Wr H EASY AND ANTEDATE ACCESS SO TNAr THEY CAN BE REACHED AND LNSTALLID ANY AME (HORRICANE CON muz OR a* Stirs ARE ROLLED DOWN. THE ETFECr OF THE A473 ROLLED DOWNN WNW STORM EARS Tr IHOW SLATS W EL SLIP) OUr OF TRACK DUE TO THE OEFLECTON OWSED BY N7ND FORCES WHO WCANO STORM BAR4 ONE STORM BAR NULL A NYS eE LEFT INSTALLED (SHALL NOT BE REMOVED). rNs CmanoH IS ONLY REMED Fur HEADER sews MA OR GREATER; 7NW 12 -O' 7. ANCHORS 70 WAALL FOR WE'MIES t BCLK CONNECTION SHALL BE AS FOLLOWS: (UNLESS OPIERMSE W70) (A) M COST NO PLAAREO CONCREW (Aft F'e•J122 pif). - 1/4: TAPCON ANCHORS 94M FACnMP BY RW BUXM Bite rOEM A1) MDMM DAMMERT OF LWCOM MOHORS INTO POUMD CONCRETE S 1 jl4' No EUV OMENT INTO s►UCCO &ILL DE CONSTW D AS PART OF THE REQUIRED EMMOWENT. A.2) W OW TTNr PRECAST STONE; Awwr COHCREw,-FWNELti; OR PAVYRS RE FOUND ON 7NB EGOS' m WILL at FLOOR AMCMMS WOU BE LOW ENOUGH M RECH THE AWNjSMUCAM Be" SUCH PANELS ANGH"GE WALL BE AS NNDIOOED CN MISS A 1 ABOVE (B) 7O EXSRNG CONCRETE BLOCK WALL: ASIN C-BD - 1/4• 0 TWAPON ANCHORS MINUFA RMW BY RW BUKOEK INC. HOTEL a 1) WWU M EMBEDIM OF TAFCON ANCHORS MO CONCREW BLOCK UNIT SHALL BE r 1/4' &2) IN CASE IMF PAirw s7L7NE OR PRECAST C>7NMCBEW PANELS BE MLM ON THE EXULTING WALL, ANCHORS SHALL BE low ENOUGH To REACH THE WIN STRUCUIRE SOW SUCH/ !PANELS. MW M& EMBEDMENT MULL BE AS INDICATED ON NorE a ABOVE (0) TO SOM N90D FRAME MRA Mk SOUDERN Pik /2 W/ D • O55 MYN, NOTES: ' -1/4'Y L40 SgDE1i6 PER HAS low ' -T/4.10 TMHCON AACROM PER ERAS 2005 . AT) AAWLRAI TPiRFADED PENETRIRON OF EAR SCREW AND TAPCON ANCNOI 4 EYED THE wow FPUff UWr SHALL BE t t/2' NO DIRE = PEVEMT ON INIO SnFCOD SHILL BE CONSTOERED AS PART OF THE REWRED THREADED - PENETRMON Ca) WNW EDGE DLSAFGE OF LAO SCREW MID TAPCON ANCHORS WO WOOD STALL BE 2' CJ) AN CASE IMF PREOW SFW-- PRE104Sr OM METV OR MCK PARE$ VENEER OR PAVERS BE FWFAID ON THE M70O NULL, APORWYLS S OLL BE LOAD EMOUWF To REACN,, THE MOAN SU&SIRITE WM AW PYANaA LDIPA W 71WOM PYENETP IM MOLL BE AS WOLOITED ON NOTE A T ABOVE (8) ANCHORS SHALL BE INSTALLED FOLLOWYMJ ALL OF I' WQMIEINA4TOIN5 AND' SPECf MTONS OF THE ANCHOR'S IWVWFACRMER (0) AFONORS REomm FOR srom 84R HEADER & MERLON OON amm SHVl BE As SPELxPTL'D OV APPLA'ABIE SECRONS SHOWN ON SHEETS 4 Z A 4 10, 11. 12. FJ & 14 OF 19 RESPEcnYELY. POWER BOLT & CALK -RV ANCHORS To BE AUNUFACn m BY POWERS FASTENER$ INC., TM1K BOLT, TZ MINUFACTURERO BY HIT, INC. et TAPCON ANCHORS MANUFAcnA m BY LrW, EAIRDETW. ANCHOR -t/4'M iAACaN t/4: CQ.X-!N SFMOTIC J• 2 1/2• MBIMRHM EMOEDMEHr _ EDGE IXSTANCE POURED CAYCREMRETE Y I J/4' (MIn I¢dIB2 PIS 1 1/ C J. -J/Oit rvK-2/ J J/4• 7/e• (Nln, I'o�.1000 p¢) 4 1/2` t 1/4• (M!u r'a•J000 pIr - .-J/e•Y PON47! Bar -J/e 0 KmK BOLT TZ J .�/4' e• 4 1/2• i J/4• r¢�TODO pIQ r 1/4• (A.SIY D_9D) 0 -1/2h Kw BOLT TZ B J{/4• 4 J�e' 2• (Nh Y¢■J000 p _ B J 1/4• ti Fe-J000 P1 _ T0. PROMUS0 R MfE RETAROU1r W IS A POLYPROPYLENE MUROAC7URE0 BY POLY m SOUL K INC, USED Ar VMW La M SMEM MR READN W STORM BYES t COURM W/ THE FOLLOMNO SPECBrCAMM ASA1 D-702 ASIM 0-63e DENSITY - MELD PANT SABI "/YP (AVERAGE) 3MO 0 (A . ASIM O-6Je TENW BROW 3250 Pd (A +Lrw+r.�J ASTM 0-BJB ELOM94WN AT BREAK 600 X (AA4D wrj ASW D-4020 UL 94 fZ A< 0.10 pd� Ah (4flE10Ej ASTM E-84 BURM PARNG RAMS SPREAD NJ= V-O/5-WA (AVVMGQ F5 •F(AMUGE) . ASIM E-64 SNOW DEVELOPMENT INDEX J71 W(AVEMGE) II. A SIMLL LYE THE RESPowniUry OF THE wmmc DR To VEROY rw soumEss of DIE STM/CTURE WHERE SHUTTER IS To BE ATTACHED TO JAWRE PRCWER ANCHOfbAC THUS SHUrrFJR SX4U ONLY TTACHED TO eA CONNCREIF AM OR WOAD FRAME BUA.OUM STRI07LY MLLOWrM7 DETAILS #Moro ON f A ORAN'B1G la TN£ DNBTALLA7ON COMIGC72R a TO SP41t CLK ALL SHIM CO MPbNERr epm "CH REM4W IN CONRNUOUS CONTACT Wm1 rw mom rD pmmvr wNb/RNH IMRUSOH CALRK AHD sFAL sH mER TRACKS ALL AROUND FUEL LENGTH ►JL ROLL -UP MEM04M ROT PART OF FM APPROVAL. RLR SHALL of Comm or AN LADE aaw r swo AGENCY: M. ROLL -UP SHU M W )ALLATTON SNMLL COMPLY NTDt SPECS jNWA?ED IN RNLI ORAN7No PLUS ANY BU2WNG AND ZOMBNG REGUTAMNS LNOWOED BY THE JURSDICCON WHERE PERMIT S APPLIED rO SP VW P-EA PREPARED Or TMS ENGMEER S GENERIC AND DOES NOT PROWOE WORM IM MR A SM S° qPROIE R, T.4. WHERE THE ST7E DONDRTo o DEIMTE FROM We P.ED. (p) CONRMCTDR To DE RgpOAM" PDJI ;NE SEL&I" PUACTMSE AND. I rAUARON RKY.LOW LSHE SAFETY OF AMS PRODUCT; a= OftTHS PED, PROWDED NE/SHE DOES Nor OENRE FROM WCONDIR= OEM= CH RBS DOCUYERIr. COAMWGDON SAFETY AT SRE S THE CAMPAL7OR'S RESpON&MV (¢) IM P.&A WLL BE COAMOINED BANW F ALTERED BY ANY MEANS (d) SRE &'COW PW=M S64U Of PREPARED BY A FLOW RECS7ERE'D ELDYNEEB OR ARCHRECT WaR MLL BECOME THE Ei4TNEER OF RECORD (E:OR) FOR THE PROJECT AND WHO MEL BE RL3AOINSIBLE FOR ALE MOM USE of ME P.SA ENGINEEIr OF RECOND, ACTNQ AS A DELEGATED EHGNEER M THE P.EO. ENGINEER Z SUSIBr TO W LAM RYE $RE SPEWIC pRAWLVOS FOR AMM . ALL IM PfA NALL BF I PC DAM AND OWOM SEAL AND SIf mmar of ME PRDFESpWq E'NGNEER OF Rom Tir PRFPARm ?., 1e. ROLL -LP AWMAMMER'S LABEL SHALL BE LOCATED ON A REMY WSAME LOCATION AT ROLL -UP SHUTTER IN AMORMia- WN SECONE BE PLACCD MRR�EVER �OPOMHR L CaWPLY MW SEC71tW 1714.02 OF THE FLORIDA BU RSM COTE ••�tC"'E��.• yam, Dam mm m pp fir. 60mm & 40mm ROLL -UP SHUTTER Y� •'" • 'r: IL E C 0, a. ROLLER STAR CORPORATION "Aflot .� �L..-� •� • ^• • .Z/ i nLUT name eaaLN¢WCCltltio oorruYY "wa}ra1► , •W.A t a Din , i 149¢ SW ¢runlMeLvxT ODD P011ivb aIDM H'•r.: row RATE 9 �. �<< � L7-000Q/a• A � v� w a 1 s� 08-189 DRAMMO M iIHL7ERA J: Pt HSDAgI BE NID7 rt • I!f[[t t W 11 P IO Z OR Ply rar.j sur s►NN (ui scAmw� erAYv�. irr► ArtAM dw srnwA !sR! w mm sir mai s r ° M Carmen fAYIIa4ma Nor Zf) OR wmur a A.IR NA7101r AN_ " mw sr Per, a ! s RN oa+crWli ARw aAaw ©H OR 1 f� ©© D O OR@ MIA [a M-M1 Oa0 fro, o©o� o«Ro 00) f-7 &WMrw MOM anw ht,r' MWW.U_ GIRL �-0©© p N016 as suer a � r roN Conom 1PC11Q/A A41r1KtAt1AfG ' Almc JJP.IOSR SMN OR �sI/!.lNif uur, nn}syy f8�lf 1!•� IAvnrwl tf;:g"` ^'�' 'u.°ard"°"Is"ao.'""'°L F.B.C. N.1/N.Z. • ' 1 ' ` �" C aow anro4 Mp 60mm 40mm ROLL —UP SNUTIER �OM M rAV '• '^.T�C= IL ECO ROLLER SAR CORPORi0N�N� Y a RILLJr TLRINO AtLNNNL[IYNO IR COY/M �! r► r ti. Noy a�. rar sr a MR, ELVARC r.m PC~ ~ rt &VU err r— rmNr Nr.c�r..6.om r a aw-M-7m 08-189 IR mr A. �ry� AL •a• swn� .ut .e.. o�.. .u. WAMW N. FLaam ue fain ._ arf[r a or it �1 .110- 0 fo BOTTOM !SLAT A 1 TYPE ! SLAT VMWA m scar fto MW lXA M ALUMAW SUF r/s•1. r- sar@ r/Y - r- .fof• 3 Tr- rrs• �s.. cµor,• .r .arc• Q TYPE As E SWMK aC11E 1/!' !• aoo• JO HEADER TYPE f Mmum r IMM sat e 1I - r• © TYPE 1 MULL/ON 4• FJr77ttam VMM sale 1A.. r• TYPE 2 SLIT kVMK m ALUWW Sur �sar y, Aao• mfr Q s 10 MW AMt sc4m r,Y•- I• r saoo• fn*J QP TYPE f STORM BAR :4S• fray a== SIW aW Sate 14' - I • so• QK HEA�nDERr YXC 2 (D HEADER TYPE 3: MW IA- - f' efOmam I AD& sra� r/Y. r• ``-+'—"' QO TYPE 3 Ml1L Ina • ',,,I raatpll se I/r• - r• a• m mm rMAmw at SCAM ,ys.. f. TYPE Ir ©TYPE 2, VMKQW AUAWN Sg sae SAD V-Wo :000 (rf>h Imo• ©TYPE 2 S RMW ,'x2• Firmtom SMW sate r/Y . 71 HO TYPE 3 STORM AR 4�• cxmuam slaw par safe I/2'. r• . 10, + .I >, r.wo• .4a•------------ e Svc mat .7 app sum• rn►, • JL_j . I ©n'PE A STORM BAR 4W, claw crmrrom mm 7wr st" 7/2• - I• ..., ., . ...•;yt��i • •. • F.B.C. H.V.H.Z , 1 � rj; �• ; 7 ;� ; o Soa rarttq Mr f� 60mm a 40mm ROLL -UP SHUTTER r° .; t i e;. --; C`, I L E C O ANC. ROLLER STAR CORPORATION or/sl�lfa wfa .' rwr TIC NO a [NaneMmo COW,%Nr a'r r4% orxrrr7xxawo r400 Aa�. • a. • .. •'fti i •' ILtl�78e-� 08-J89 CNI No S AITdI!71 r .. i • . � IIb del III III. II II I; p 9:1 r Q%*(=I-78) A tb1/r uit FRONT -SIDE V/EW �OTTOAI_SPR/NG—LDADEn _crcrrm scAAEr 1/s• . �• elk L--J ENGAGEMENT HOLE ULM (IN nveAR F PL4STIC BUSHIN .• .SPRING -LOAD n STORM BARS DETAIL f (ISdM ra�r 5r4m 1 • .. SGILE I'. 1' (1) EMG46EME1Vr HOLE DRMIEO W G10VMW SWL.BE D/E%rf' VEEP, w/1/1e' Alm MURVrCE IN RIM DNMETER d 'OEM. f�I A9POAfasor Aw AH4= 1N QONCREAE sm u BE PERM Wmi PROrEO1E0 or nmw Ptmm ANAS" ls6E MIX 1) wro HOLE f SHALL BE THE wPOA&AM W of SHUTIF S OMW Ta PERUWWXr HEED XWAC FREf OF DUST MIXD By, REMOyNO f FAOM ENGAGEMENT VE HOLE CLEUNNO ? ANDPOS/T10NlNG f !MO HOLE AS ANDlGTEb ON ABODETAf1: z Y OrvEHsroNs FOR A Gr & TYPE Or S1t7RM BAR .urQ/0 °fnrr Aw, e r �+• r mtrar x r ra/.n• a tyae• 1 1 ryas' a r+V.n• ;y4•.�;}��'s; vim. F.B.C. H.I/H.Z. �.+� i�;,3;.� G'(�"7 • ' o raw rarsq rc 60mm .& 40mm ROLL -UP SHUTTER rma lwft . Y C= Il E C O iTEe. ROLLER STAR CORPORArjoN OFMAN •""Crr!?.P, �G•� - � TIUR MnNCI s wQIMMM a OoMpmy RUN~ I� oawr squtO/w 1{ao .-maelr:...Kenm A8-OOOgI/ A RJf A•. Il, a r wrrr rr n� r ocsr rn OB-1B9 O1GM71N N Ra.Ue t<1 It. U,o 7 � • 711LIT { Oi 11 V NOTE 13 ON SHEET 1) RV 4M RV 451S HOUSINGS 1 (O" NUM II Ury SHEET 1 ) chum APPLICABLE COMPONENTS FOR .FAR. OPERATED cvcrr,L! - GFitR - UtOWMAL t CRANK - C/dWK HOLDER(OP"WL) OFAR t XLE CEW R7 ACONNECTOR) - ^ a1LL WARM - OCTAGONAL AMLE • umm • SHALL BE COPABLE W SfJSrAW SLATS - S!lm G GIP DI�- NMff AND ASSURE UFIM MECtM= NOTE 13/I) = FRONT t BOMM), aO4O' YINCK - PLW^-BLRTW4S - ALUWNUM SLATS -.BOTTOM sur - PUSRC STOPS(Oprxmva _ srLocwawwo AP MMPWAWj - 31PMAU= HANGER - SAFETY MAYES aaLila�NAL LtlLAfINfAI/l•f12o ' - 71BUUR MOTOR - MOMR BRACAW — Swmw FASMAM ®'- /s srax= mm scma (s REOG Et SwE aq : 2 O TOP, ? O REA/t, !O Borm t f0 FROM F.B.C. / (H.V,H.Z. ,•a,e0 CONOW ON At .r ` ` • 2}r.ti►' o.► AMn KOGr / x 0 sear w raweo oaAartr at �'� AK*V WPM AN914M 0'' 0 m � on a on '7y's7�'k�ggL qt J 1' rNteuN' mt r/r• t/i- Vt• CmG l�awoar rca� of ?OR® 1OR® %s"NWf'I• ac Gs 4ma La aR® T ON ow f L3 00 GRMIROf B ©D cvm NOt tmGa arr E OR I I w M LOR OM E OR Ei ri Fur 8 C MOUNT oot MA N Op E OR `E J W— i OR W-2E o r/2• !NSlDE MOUNT t .r• sour W. r• 8U(CD—Ol/T UOU sEtcrmAr O . � O t SOW. 14' . r • N SIDE RAIL ANCHOR SCHEDULE (FARCE �� t1DNCRETE BLOt�C sour f/2• . t• MAYWYM ANCHOR SPACINGfin) At SIDE RA -0-2- TO POURED rocwED canrcRETE .0MECTION CO HCRFTE OR AIASONRY WALL (USE A[AXmium VALUES BETWEEN PCSITiVE AND NEGATIVE LOADS) VESCM SIDE RAIL © ! SIDE RAIL Q SIDE RAIL QD SIDE RAIL Q SIDE RAILLaW Et ii (pIA% na/ srowrK,%V rW iaMr iwt rover M71/tl M%N► WL W'W yp�y� M4 YOLMt ss OR LOS a• s• a r/2' a;• s• a• a• e• a• e• e. e, e a' J r/Y 0 r/2' p• ♦ r/Z• /' t 1/2' a' a' S• a• a• e! e' »sTD80 a• e• a• a• r• e• a• e• a• a• 0. ®• a• e; r >a0 TO 100 80. MIA S. a;- a' C r/Y s 1/2' 3112. Y a• 4 0. 0 • e• >1LG To rB0 e 0. WA •• %' WA 4 f/2' WA' +YA'' .� a• J T/2' a• �• I' a' a• ►/2' a' a;• s f/Y V. J r/2• 4' a• !' 0' Y I' I- e• YAX/ARlN ANCHN SFKCff= AR'VALID MR J• EDGE asrmCB FOR E. a .L mw J, REVOLT ANOYOR SFACIM 6r WAY/AYMO SPAWN (S(��I/ppM� ON SL7 M" Br THE fOLLO*M FACTORS BE REOf:CEO SPACNG OBWMEOrSR`�" FACIW MALL Nor BE LESS mw 57: ACRML E D. FACTOR r r/2• Gas o/ 0 OR OO rhos 9' = --#-�- t� W-1 OR W-21® SEGlMN .R —� L MULlfON MOUNT (FACE MOUNT) scvr r/2•. r fNStyi• ssc�r2M�i • GG ® O' L w/ mta atr OR O Swnw R — R t MUUJON MOUNT (INSIDE MOUNT) nwr t/2• . •r• ?,;.y�cEiT�•.E�1'. F.B.C. H.V.H.Z. ��•• 4.. A• ; L:3, <{ 67 = ; toa 60mm & 40mm ROLL —UP SHUTTER Y0 " ft 3%' ' • I L E C O IN- . ROLLER STAR CORPORA170M o>awr ,f ,• l,•!• (� �' : r R TIt11t TOtINO t INOI Na GUPANr oM"tir�. �� :� n� ��O p W�AWOP/{ �/L IrftPD Mane /OP-Ali••7tar ` , �,�ij�� i �e rq��,p. .`••���i ra•a�oorns •• • sr. .w .•. D8-189 DRAM N. flYY'•{'�+.aMW WIt70t A ALJLJL___ rtara eAs urw _ !MQ► 1 Or t1 it 40 L Im _ dot" 77 MMOy ONDMY17p •" arm r v aw ■ t- . ' 1 tl00D 0 set -ea at Ulm .,aes.v`� . wwvMm�i'�.:�,,..�-M...w 0.7►/ OIOtr AMMO All AS 01►1 AIIW1160 ONiI[[7Xm"s toallaux MILL WA AO NOUWWWO awls 07701 °"� O 3 -471 ,„71 w 1 4LLnH5 do-770H um as, jr wW09 muu amp Z'NA'H 9 771 W 137rx 310NY yxrl IIIAJ q,, r .®a0 t@wJ 5».rl® • IY07dYt R►zi AK UM? xi A." Wt' p .0 p0 gyp /M/M S Y H 137im LS - Le unlfel=. A J7lNG` Ci�l i11AOc'' �%17111 P-1,yt' i0 OT vs 37cs 030038ILi A Mm 3MN9101 37Mdo ' z� .. an d LJ ON KZUM j TZMM Uam ¢S F7[ m LY6 '+WI 01177_ .l - .94 : 3W:29 0 .l -.i/1 f awzt (ire m4w //,�yj \uy\j-� ,tea /irsw7xa�s xu .►A �( /ii— O- 2 / 1 aa� .! � .►/1 � 37gSffOU= If ifYLp OW Shgta>s Aw! ]7MA' _ Glum xmr sw +el`a�w W sear XW >ra'r>vA0i owns,"v"''may I W=jzm - do O o� j - ow o Q!�00 O .N PIVWW' ku r. m Immm rcamm i I_ +a•aw kw w ywr :v.• .IYalor v Wad i _ I s^P"'1-yyn� � I P SECTION S — S ! SCALE r 14* . 1• Y•--r• u �•� I s s L 1 J K ar 11 I •i'� dL=usJ n i i q,�J srrra- Fat© = SYMf Fat ©• s+- m. I sysom 1 A sl 1 1 s �y �i•wa sowMtcw m alwu 1 i 1 I 1 1 I at ® I • iwc >ln/rin0rr TO 6iA7f s Sam ` j q C � � 8 r � e© �a j u• 1 1 1 I 1 I ©© II it I i 1 � 1 l O O or f p j CplaU/rOMAf OF (yl/.b LYYYW ANCNOIO� 1• O ( E1 F it ; v, I ' a� 11�[WYT7 m �D61� LpK7Rfi' 1• as K /1LNY dY11001770M II 1 1 I 1 a. © i I 1 1 1 I I i i 1 j I 1 ELEVATION X ' SCRE : 1/R• . 1' n v it i i I F'at© 1 I S I IS 1 i 1 sl s 1 s O© swlae W. n I g O wmw x D I OE ae E1 sysror i ii s 0 O at f I ssml a Y-taYKO WI MM,r6i d warrc (aloYol .- �•.•..�. •i ��/ mom 4 • .. • • 1 1 ORO•44157 awaa� • rA' roarm aa+anr w 4 rk7Z.7�r/P ftw. mPas w/e w cammanor w ro / ati nlrcav . • f • +• as w 7 cow" - F.B.C. H. V. H.Z. am oRCEILING A• FLOOR MOUNTING INSTAL/ 6V W/ scax aaally v �M POUND Ca Ane a 4' ae All, o !� - y ft R£MOVA R' TOW SIRS W/ PWM—LOADED M7FM • WALL MOUNI7AIL` INSTAU�t W/ �� 60mm & 40mm ROLL —UP SHUTTER a°�" „/''-'' RE,MMALC STORY ARS WASPAWQ—LOADED SYSTEM • i IL E.0 O i ,c. ROLLER STAR CORPORATION 0Y41M • soul: y.•_ r• SECTION V — V !3) • s = . -11 rar srlcs I r i i I I 140 sw" owtr rlPCYN¢ tar OAft r0W1iW rcvac n. aroaa rn..R uw-M-Mn 08-189 an r c...w wr sr ■ s.r .� 0rA1NN0 M• �_ r+rar a or Ir Ipu7F'ALML PUFF w v,w f 'SN rAfrnr AAOW • tt,`ac • Fr in .Heir Faaa im L nDMAof e 11L1OOf aLrFat°a O m Maw - MT ___—_ .n a.w .uf Unr GLIIrG/fl°Y4S Svc.Kim t L— ►RAAW PArAND lw ,,iy L (D SECTAO/d S — S;/FAD ntren SCALE : ALT.S f i 1'bn!/4' IEK SCALW S� _ erne.e ,..... IF A r /�/ f1CMSGf wrsow O O RAW � . .� t�� i t 'Fr/°y ' err► Far wsFutArnw retry eon crvnty , (Zf/4'YOr7/b' oMJt-w • ANOhblf! , SwMw, SCALE : MI.S o 0 0 0 JK ` AYr cav .a wtoEN.a r far •; r ! EO USf .. EMCNINE SCREW f S EIGit /9a[ far AW EO • ' F — 0 PLA L40 =NGO'Vg FOR LFAWJ/,'tvt SMW • 940 r•'; : • ANCNOW i amp / AxTS Y si litiU O AT/r AIL SCALEp' - 1. OR® Y�EO M/CtAItr SCRLMI ofw- i F 1 ( _7z 4 F1e` Affi Wff A YoSMWNS na siAeseeet�Fcr Err WM Ar LtOCE7Nflt M/ ANOMORS Ar TM taFF' ; , STORM MOS ARE RFA(M ($EE GET. 4 (i • ('l/ Q�i� rM 'r �rM M MICA ANOr,,I/,Ya�I1' TFI. SCRtf! / XL L OLYKILLTC W/ O—OtN� >ti S7aEY MRF AT Ual SEfE FOfAa� E PC !jW IMSTIIIIUN aOpr � CMWJEiF' �AAICAMNS WAff IFFOL°Egrplqlz aw, r Mrt SMWAH V - V 000 e" i Si Me] ) or M �ET-Q "T grJ E»kr/�So _r WN SLOE AT r valr f/f4f/A' F.B.C. H. V. H.Z. 60mm & 40mm ROLL —UP SHUTTER vmw °N 16CNU ROLLER STAR CORPORA770H 07�n r,rri corttr rt r40 P»•K°F-toeF oa-ras ramp. .pf .., erg .ue O"W" N. stacr 9 ar is 0. as m'*,r, a :,�.•_ r• .BEdIDJ • srr ar n ,ar s xr AmposS V — V a) . oo-o ,o.© 4L L, ram/ �� rr ,• �'t7M/IPm OR (yt/IY OUCON NA7AwY..• ��::/J DOOR, 04Gr. Ar Er.�►►�nav x �: rye•. r or CM F�LWN64 �t � mwaaw •�¢. ... s ,••_ / • � NRtNNE ao�r:, P. r' `•.f.".�i._....A_• c� naai�cmN° WtrNp ME VMM fm ..ANQfW Q =�9 F.B.C. H. V.H.Z. 60mm & 40mm ROLL —UP SHUTTER ROLLER SUR CORPORATION 0000 MW m tM court etwaro raoo 08-189 • �� tae .K. e� .�. mwm No , srxo to or n at !o It am - • • aw wln ar worov T� ^I" Jlllll Y mnNN NI •NWY•a 691-90 •10m r ws an worts r v root-sat-oa s.e w -som0-�) `��. •• . .-91 Mu.'r$w""�5'lL.:�wa u,�. a ',am _ .: 11 %y Ng7ffi+a tl + ANWNOO ONW77NION7 i ON4t�iA JT4� rj'� • ' C. �y�s '-r. «�,�ia Nou121oda�oa 8E�1S a►3noa •°"� O�3 '11 :•.:r Y•1/'Av'n YaNmna 21311nHS d/I-7702i ww0i iP ww09 ' i :Z7 '0 :4•'• 33? • +• %�. • Z'HWH '0'8:4 . ar bntivl bor p . •.35. ; : '• �: � •' �� � A-9J' , Aan'Nymawa 33U 31gYAf AID RAr AVA K • .l • .R/1 : JIM � w Mitt 'i /N�p1,4 ov.11 I 1 Al1Y0S Jdl fXi0M1. MW iA9W • 3fiR1 3wNY mTY .{�/ PM.►/, i� !o NGM1MYNdYdD7 �CYY �������� �� Ni+(wrd,c+t,rr �3N1 /■ 71avr wN1v uw ,R/++t++R1lar rcr�r1sry7nvaaau 0 ao 0 O,O L !xr aW n.vt (0 anmm rim 47a mw ILI/t (t) Xava .� l�J IL l7a1 A ms /.I/Y is wom I aw !w mew AL44 W spas au! M Iww xu nww uwMx sr►e ® 7OUVAM gar are MU MW ow. a SWMAW .1 •.t/, +S710C O o O I= let o 0 0 _yp Q09�1+NNww .1 ..•/1 : YMN O NW79 3C4x7iM �� SL�11747V// T/f .f Al3u mnwr W II u r� n srll ,,,,-a,nc . u op ol M of ' ,rl • on .a • >awvaw •oa+n 3vL a oo .al ! vv .r, a•wm Noma M iiWur<>+al fx+vl+'rolaU.s/T+IL►H qA' ++i../i h 3w+ sr7�ex xu /ir7aw wU.►/rxs/i ; /� xtt w'nr yaa.✓+^f /M mvm wmN.f4l'I.R�+ wfti ,Noa .d,•f�l1.LKI 'm >tlru mw.Z,.nv, 0 qB,n r—amp no A AcrrcY sic-tOraoo L arsra V A M MIT W/ I/OAFi4• me solrlls � n' as I K © ft �p�•��A[� K • ■ r•awr. i©o � K fi II Air I of IJas vw:oulr ' Pam caw % .4; N�tae'1d°0ers rua�r y�Y,µ• • u• ac snNnr-wsm srsra (D1R(D SECYIONS, — St. SOU: r/a' . r • G (D ._ F©0 ORO K � r IY 7APC0/l � ra• as lnr. uaN ���© Q ED K Ia �• Y Ia' �1r11A•CtWr AWL SCYCDIKG ©Q rrAlr (our s clan �� �� *��u sk r/s• oavr ...I�aiA nON w �. V@ ON. jtxtr u soar r FA* _ ,• offmw AWt Mar four. arq sow Imm aIERD ••CASE 410C Vl����,.. NEMION AT BUILD=OUT G—LOADED SYSTEM +� • f �' ;� n- tr, -g ; _ ::' M.:. Ic, i • a a or it mt was '•.• �i ANIp M ! SI M AM S69fD U M& Q6YAML Odra afN Wir AND= 11m arch " rnr I1oo t (�► +NY rows wa LrJ ar mz (1) 44S Aat aorta Car a sa/ar IV "V rolmr mr 010 CVAW i fp 4 Iy Art rerr 111 O am mim Nc L ECO-r . F.B.C. - H.V. H.Z. 60mm & 40mm ROLL —UP SHUTTER °om ROLLER -STAR CORPORATION OPAV r� sw sr �o�nMlrallo use VATC 08-189 Ion... re Int. rnr1w w WAINNera I sxrrr Ia W a 1 y�AAiDyam IAA' far, morm 1 � 1 � i 4 I � arYaytw•� -91W M owl -NAM emir a I im &K la sur mar Frr ww C, 1 ar" --a--.. 0" uk— 4 L4 yr L, 0,LAf i FLOORCRUW A OUNnNo: 8E0770NYKWrl1. Wit7HEADER i S&,nrm N w•WtzI WiNFrA smut a I/r . 1' tat{m7Q�1M�O�WN CKY MR 30" SANM ' rlfl3mvt3 PM.E1a1 SANDAL Sport Pr---^—� I 1 I L 1 I r„• it � I 1 f• o 0 oK L .>,r• aaf .wr, �O n II n D ME E =Yd4Lnt&L/��] %TkPMLSF" ^^"'A/ECTrONATENDB' Bouts Ip'' 1' SEC7TONiKW i I rJ I fl 1 Idr .— Fall Milo" lo" a= FADMW aw r.,w o 0LLY AANK L At � t j �4�ra FmW mar w mramWAM aaomw mfMDom� mvs r LA• . f• Ewra"°r�"d AL7ERNu711IF� TYPlG1GHFAOFRCONNECIlDNATFND3• SECTION 1%W -WALL Amf17NG: SEC , W-W/31 AM , M:.,A C•&VIL AMO1tCL TABLE 6 SaE r/�.�y 7 ow COLT tt ,oea rl " TI; r.., . w__ m mmmrzz-� EWTZ1 main U29mMtif... �•a _ ®� tttts� m1m,-Am �� u _�- ttsENTM�mmra- nur--Am on 1110 --'ll �o�dl �7 7fADR ! i'7g11( MR NLORD. MWO IF/ /AX WW.. k Er • 1:• da EL MEW W/ 1 1/r," cgilr �ElAIR M • sWriCommft u W o LVLUW +1N,L lfAEM7t SMNrf SMlfl mr C�= MILLQ smw OH 'AA st�rtt av sxnr la WALL61R;m D,.uc st>a fa,ratxK/r1/,'t,.AM7ARG,a�oa 1NQ:Mr21Ml11MA/NECiION AT 7:)Pd.BOMW•3ECMNW.Wrfl Ol$GM t.l „D Arr w!'.Oils MUM M9W AMr,'.D' r<ZnmmomMUMWr L mwt 1 f/,• 1' F•B.C. H.V.H.Z. r` yF • 4' Dam60mm & 40mm ROLL —UP SHUTTER 10 . » • STt a :.�;.: `'' � L E C O 1 Ne. ROLLER STAR CORPORATION D'un • '''i . •� `"� on a Mra �arC.dmw PU taw IIiO SM' RA L'OfRl 1<OC �7I�I�LYO ,p�Cl7Ld! � pg— f89 �• '\ — -�.�,�ry� f1lW Wreck AWr.F. RC arw raw re a+tr ssr� AU" Oft Ram U. Hfly _ • mm N W IC (Z,14A'H) % 10'814 n.8 '.K& 137MJ�Td % -� 1 i � � =V 1 • V �l % • • •: •' sM7 M NO Sl YMS 0Y7 - suss , y ..�d •t7: 1; 3'e oc MOM W= cw .CLAWS dO AUUM3AW WMW r Tnor W XV A,aalr,M7 &*a7 IM S VN 3Wd NrGWW 35 al MRW MW 4MIL'k UMW aqw am xu T .7k OW of W SOM)7 NMW MlM WMOW MU W M d7No 3MY ZMliY77 ZM -1 1m N07AN /M 7I3�W a/ 3w.N9do.a /M S / AliiiDS 'J/Y! J I+3S d d I awo9 • MM.Kr •i, SIIjV ll f/ X IA -,Ma aN 3l� .io NLQiNQ/Y Ia �oo .0 a .sl�Ml7S .►+R►/� cow tales) 37D1W I ©�D0 k OOC T 7 w SLAT PERFORMANCE .CHART., M YN NEGATIVE DESIGN PRESSURE RAT1NG OW_1424) AND CORRESPONDING UA_Y1LyA/ czar SPAN "L' FOR TYPE 4 A' '2 SLAT (USE MAXIMUM VALUES BETWEEN POSITIVE & AEOA w LOADS) SLAT rwE ©W/ 370E IL4L ©II/ SmE Po12 ® ©W/ SIDE RUL ® +,9 W/ sw 2A¢ W/ SIDE 2AR MAMABM WSMV LaC UAW" SLAT SPAtI ADM SER TO CLASS MA M&* SLAT SPAN MAN SIR M CLASS MAWtUM Sur SPAN AW. SEP. m am A14NWW sLAr SPAN Aft SEP. TO oAA.ss AKXWW SUT SPAN MW. SIP To 01ASS Tao 7'--o" J. 6'-4' Y e'-4• J' 3-4• J' a' Ja0 6-6' J. 6'-0' J' s-0' J. a'-f' J. 4'-fr J. J3.0 a-3' J. 3'-10• J" 3'-tp' J' t 4'-101 J• 4'-a' J. 40.0 e'-2' J' 1'-7. J' 3'-71 J' 4'-7' J. 4'-e' J' 45.0 a =0' J. 5 -5' J• J. 4'-S' J' i'-4• J. Sao 5'-10' J. 5'-4• J. J. 4'„T• J• 4-2• J• MCI 5'-Y• .J• 5'-2• J. a'_2• J• 4'_2• J• 1-0• J. 60.0 5'-7• J. 3'-0' J' S'-0' J' 4 =0' J. J =f i' J. ea0 S'-6• J. 4 =}0' J. 4'-f0' J' J'-1I' J• J'-Io' J. 7a0 a' -a" J' 4'-O' J• 4'-a' J. 3'-10' J. J'-i• J. 75..0 5'-J' J' 41-a' J' 4'-E'_ J. J-9• J. J'-a' J' Rao 5'-2' J. 4-d' J' 4'-e• J' J-a' J• J'-7' J' IIAO a'-f' J. 4-5' J' 4'-a' J' J-7' J. J•_e• J. - 4'-4• J. 4'-4` J. J'-a• J. J'-S• J. Sao 4'_ f• J• 4CY J. 4'-J' J' J'-3' J" J'-4- J. J. J-4' J. foSD 4-9' J. 4-2' J' 4-2' J. J'-4' J. J'�Y J' ffao 4'-8• J. 4-1' J' 4'-1• J. J'-J' . J• J-2• J. 71a0 4'-7' J. 4-0' J. 4'-01 J. J'�T' J' J'-2• J. 12aD 4'-6' J. 4-0• J. 4-0' J• J-2' J• 31-11 J. 12a0 4'-e' J' J-1t' J. J'-tf' J' J'-2• J.. 3'-1' J. TJaO 4'-5' J. 31-16' J. J'-TO' J' J=1' J' 3'-0' J• IJaO 4'-4• J' 3-t0' J' J'-IO' J' J-}' J• J'-01 J• I4ao 4'-4' J' J'-ap ' J• 3-0' J' J-0' J. 1410 4'-J' J. J'-9` J' 1 31-2' J. J-0' J• J' f30.0 4'-2' J. J'-d' J' J'-a' J- J-0• J. 2'-1 }' J' Ina 4-2' J. J-a! J' J'-a' J. 2-1}' J• 2,-1p• J• leao 4'-}• J• J-)• J• J'-7• J• 2•-tf• J• 2,-t0• J• a41B7; C � QUADRUPLE SPAN Ccl� TRIPLE SPAN C � DOUBLE SPAN C��� SINGLE SPAN • MAM w sfFNfOtltON W pass MR SAME AND MIA.W UMM SlWL aE MEASURED n[OM KICK Of SLAT l0'Ct WS F.B.C. Aaoi nma 80mm & 40mm ROLL —UP SHUTTER ROLLER STAR CORP. ORATION Nf0 SW �'COW eL'AAfAI' Ito �77i-7�1 L ETC 01NC.- 7X0 ! [XOIX[�IIIpI0O1�0, COMPANY ILLY _ i�l .ti! PWf/l�l 1 A'XM: owNf1 m fiev,� o7/ru+e rxlr 08-189 oft"M N. N[T Is or 14 MAXIAMM DESIGN PRESSURE STORM RATING BAR 'rW" LOADING (o.a.f.) CHART AND CORRESPONDING MAXIMUM SPAN 'PLO FOR A GIVEN TYPE OF STORM BAR ANQ S70RM 8AR SPACING. (USE MAXIMUM VALUES BETWEEN POSITIVE * NEGATIVE LOADS) MAX. SPAN AN SMW BARS W REMM COMORM ANGlf M LESS • STORM BAR SPACING SHALL BE SUCH THAT MAXIMUA! SNT'SPMI SHALL NOT BE EXCEEDED• F.B.C. Y ; f:a. r•,7 � 67; 60mm A 40mm ROLL -UP SHUTTER "KAAA. * sr.. _ =; L ECO1Ne. ROLLER STAR CORPORATION 67:06 J •• n` • w • •v Tsonka-! Dan[[RNO COYMNY V 1480 Sw a ew" /I LM 14M • �. /01/rNV iApL Z STOa! ph&, ao-lm-ma 08-189 �• �` �rurw� .. - .�.. -. -. - w..� .�. a rtrtNo N. rtaea�� ; PUT la a u AMXANf1A1 DESIGN 1MfpllOw w 2• r Y r tip' © me®srtrw� © Y r s• r nn(,1! ;wnr err! Y r 4 r 1/Y'a © mrpm>ral au 2' n �• r I/�' iV' ao # srtxrr ON anawa * claw srr swcs•r - * crow aw ,pMclw? ♦ arow svrana►a < J'-o• J• ro 4' 4':ro s' J' ro e' e' ro es' < J'-o' 36 rtr e' a• ro e.s' < J'-o• J' ro 4' 4• ro q' a• ro e• e• ro. as• < J=o• J' m 41 4' ro s' s' ro e' e' ro aa' 43 ON t•�• a=l1• a-4 s•-ro• a=t• a-o• s'-o• s=a• a'-fr• a-!1s-ot-4t-o►f'_a• 1o•_a• to_!•Da'-o's-4• e-o• Mr-41B,-7, s'-e� a=s• s•-a•a'-a•a-!rsst=e• a•-s• -D=4•t'-J"-aro'-2' D=r -a'-D'e'-:• a=e•ram• J'-a'rD•e•-r!;ro'-e' a=rr• a2•a-4•es e-D`a=lf•a'-4• 4=ro• -r-1• s•-o• - e'-t• t'-s• e•-e a ro•-a• D-D• e•-!o• e'-11 - ts a=r a=e• a-!• s•-e• - s•-D• s•-Ir• s•-J• 4'-10• - a'-J' r-r •e-s s-ro - ro'-4• s•-e• e•-a' t'-a• _ is 6'-4• s=e• 4=f!• 4=s• - e=r s'-e• a•-r• 4•-e• - c'-o• r-!r• e-a a-e ro=r• D•-2• a-2• t'-a• - eo a•-r s•-4• 4•-D' 4'-4' - c=4' a'-e• 41-11• 41-e1 - t'-s• a -a• e-o s-a D'-r!• e'-r!• t=rr• ta• - es a•-0• s•-2• 4-a 4•-J• - a=:• s'-r• s-9• 4•-4• - r-a• e�-e• D-to• • t=e• t'-o• - Do a•-ra• s=o 4•-a• 4=t• - e•-o s'-Y s=e• 4'a• - r-s• 0-4 s-a s-2 a=e• Ds4=fr• 4'-s• 4•-a•D'-s•-Jroo4=D• 4'-J' J=rr•4•-rl• 4'-3• 4•-0•e-r!•a-oa-4•: 4-rrr- :7'-? r_ra'-a•.J-J'4-04-2J'-t•4'-10'4=4'J'-fi'e'-D•3-f03'-J`;'6'-!!'.e'-4•r!o Ira•4-r4'-e•4•-2• e-a• Its s'-2 4•-s• 4•-0• - - 3•-+• 4•-7• 4=r• - e-o 3-t s•_o•; _ _ a_r t•�• e.-e, 120 3'-0' 4=4 J-fl 4•-e• 4•-0• - 3-6 4--tv � - a-4• r-J• a• -a' - _ f23 4-11 4 J'-)0' - - J=1• 4'-S• J'-1f' - - e'-2• S-4 4-10, - J'-2' 7'-1' i'-4• !JO 4-l0 4-2• J-D• - _ 3;•0• 41-4' J'-f0• S-J 4-D• - a•-r• 2'-0• e•-s• - _ fJ3 4-D 4-1 J-e - - 4'-rl' 4'-J J'-0' t-r1• e•-fo• a=r• - _ 140 4-a 4-0 J- - - 4'-!0• 4-2' J-D' 4-e - r-J' a'-p• e-0• _ _ 143 4- 4-0 J- - - 41-91 4-r' J-a• - - J-D 5-0 4-a� I50 4-a J-11 J-B - _ f'-0• 4'-0• J-7 - - 3-8 4-11 4�3- - - r-a e•-a• s•-to• - - rss 4 J-f0 -S - _ 4_t• J-J!' J-a' - - 3-0 4-10 4-4. _ -4• a -s s'-e• r60 i-4• J-D J-J - _ 4ta• J-1f J-a - _ J-a -➢ 4-J - wx. SPAWN MR MRW Rues W1VMW-LD4D[D SMW f6U0MUM OES10N 1r>s =w?W D'Sd7rf/4 © ez.r 6N WE S rrk./11/0' © IM S rlaw swr ZY.�tt/�•' MG / rraef MT 77N'ki/4' O LOW 'by*(p.r./a Slaw 6U 1'11CM Slew MR SAWW Raw SM sNeM6 SIM MR Sg1w c 4•-0' Y• To J' 1.31 ►0 4 4' 7D 3' 51700, 21-01 7' RT X Y TO 4' 4' 70 d' d' 70 6' t 1=0' Y' TD 3' J' ip J! 4' 10 3• s' M d' C 2'-0' !' 1D J' J' TO 4' 4' 10 s' a' f0 6' ya 7'-01 r-6- 7-W r.4' 7=f' r-0' 7•-0' 7=e' 7'-1' 7'-1• i0'-0'• TO=O' 0=7-: 7'-e- e'-4' 1J'-e• fl'-6' 10=7' 01-6' r-1' •J0 7'-e' r-6' 7=0• 7=1' 3=f1' 7=e• 7'-61 7=e1 7'-►• 5'-11' f0'-0' 10=0' .6=01 . 6'-4' 5'-4' 11•-6• 111-6' e'-lo• 7'-1' J5 7-0• Y-e' 7-6' • 8'-11 5=0' r-6' 7'-6' 7'-6' 6'-1• 5'-0' 80.-0' ; D'-Y a--f . T-3' 4'-r I1'-e 10'-f' 7'-Y el I.. 40 7-B' T-e• a-e- Ot4• 4-a• T_d, 7•_6• e•-0• a•-4• 4•-3• i0'-o• : E'-o- d•-0• ! 4•-D• 4'-0' I1'-e' e'-!0' 6=e' a'-4' 4'-S' 45 r-e• r-e' a=11• 4•-e• - 7=0' 71-0' a' -If* 4=6• - 10'-0• 'r 1 d•-4• F 4-3• - Tr'-6• 7-10• 3'-11• 4=e' So 7-e• 7-11 3-4' 4-J- - r-i• r-1' 3-4' 41-J• - Y-r s 4• 4-D' ; - - fo-r r-i• a-4• 4•-0• _ 55 �'-6' 01-51 +-IO' - - 7'-6• e•-a' 4'-10• - - e'-a• 3'-D' +'--4 . - - o'-e• e'-s• 4=To• • - - 60 7'-e• a, -IF' 4:73• - - 7'-6' 6'-1►• 4'-3' - - e-0• .3-4• 4•-0• e'-10• a'-ir' 4'-3• - - e3. 7•-0• e•-0• 4=1• - 74' 31-3' 4•-I' 4'-1T' - - 0=?' 31-5'- 70 r-e* 5'-0' - - - 7'-6• 3=0• - - - e'-fo• 4=6• - r-r Y-0' - - - 7s r }' 4'-D' - - - r-r 4-e• - - - 0'-4' +'�T - - - 7-r 4-a• - - - e0 6:.a• 4'-5' - - - B'-e' 4'-0' - - - e'"'0' 4'-0 - - - e'-a' 4 �S' - as e'-7• 4-D' - - 6'�T' 4'-Y - - - _ 3-7 - _ - - _ 90 31-1f' - - - _ 3'-11' - - - - 3-4' - - - a-11• - - - DS 51-7' - - - - 51-7' - - - - 61-0' - - - - 51-7' - - - 105 3-0' - - - - 5'-0' - - - - 110 4'-JO' _ - - - - - _ - 4-4•4-r0•IJS 4-7 - - - - :4-f - - - - 4-2'120 4'-3' - - - - 1Y5 4'-J'- - - - - - - - - 4•�7' - - - - 4 STORM BAR SPACING SHALL BE SUCH TMr MAIOMUM SG1r SPAN SHALT. NOT BE E7TaTm. ..... 4 l a7 - i F.B.C. a [o of Lnxr nla an xvwlL 7V 1'YIIt YYlIY,W o� •N rNlCr710 aw w.w>o � ap M ro w v IfLr000-@t - .fit. 691-80 f10Y1 JYC11y J1Yp0 1 AAriN00 CHM32mim i ONLLCU Imm ^ i v: '� •'.v •. . Io%lyLe NOUYNOdMOD 8Y1S N137708 ''"' O 3 �I `'► %� ; ='=;Ya 'WAWA allMHS do-rroa wWo* V WLuos •—i ;12 a. roawa/ coos p • • �. MAI-, �9007 3AUY03N i 3AI11SOd N33AU38 S307YA I4nI on 3Sn) MUM 4 w • w w ,r:L,[-LOset .fi-,aO'OCt!e.e.sa-,L1!-.a.el-co'ar!,c-,c : ,c-,a ,r-,tr .► :e .a :e.r-.s .a :r o'rc'! ,1 ,e .a-,c ,r:v o'ort ,o-,or ,F,9 ,s :a .rJ:► .v ;r .IJ :a o'ur ,a-,[ .►-,a ,r-,e ,a-,ol ,e :rl ,L-,s ,a -,a ,o-,c .c:e ,o-,r o'Dat -,a ,e-,v .r-,r ,a -,a ,r ;[ oYl! ,F,e .or-.s .F,9 .o-,L .ol :r .r ;L onrt ,e-,e ,Jr:ot .[:al .0-A .9 :a.F,r ,n :a s-,a .a -.a .v-,r .l-.9 o•aot ; ,e-,rr ,F,1 ,ot-9 ,a :/ .[-,r ,o-v oxe ,L-,1 ,o-,or ; ,e :rt .9-,1 ,Ot ;o! ,1-,ir ,0 :il ,a-•,1 ,r:1 ,01-,a ,a :DI ,tl-P ,.L-,9 ,► :a O•N .tl-,9 ,t-,L.1-,e .9-.01 .t-,a .O!-,9 .a :a 01Da .01 :O! .r-,Or ,ll-,Ot ,1!-,!1 .M,Ct ,e;PI ,r-d,a-,P ,e-,e ,r-,11 ./:a ,r-,a ,r-,or ,e ,a ,t-,L o'sa ,rr :ol ,e-,Jr ,r!-,al.o-.P s-a ,a -.at ,a,rl ,r-,rr .ol :e .o-.rr .e-.sr .►-,c .r-.a ,s-,ol ozr ,ro ;n ,u-,ar ,r-,►1 ,e ;rr :coal .a -.a .11I .i-.a ,a-,ro ,F,cr ,e-[ .v-.e ,u-.oc oror ,c-,zl ,1-,r+ ,u-,►1 ' ,a-,aJ s-,e ,u-,e ,00-a ,a-,ar ,e-,ar ,v-,cr ,►-,el .e-,r ,F,ot ,a :1! ,ol:a! ,or-,rJ .a -,a ,a-,e n o ,rl w ,zl .a! cu ,or ,ot of ,P or ,1 ,it a< ,rr ,ar Ot .ol 12411.0 ,ot o! .v ,a to ,a ,o :v a ,ol of ,a ,a of ,r ,o-r s nr�uv Ire lenrc tAacrr Ire Irrols rfmfr aAe rNlurs t'o o? O YiOYaYr®� :►/1 +.► �,a ©l170Y7I®3dA! P/1 r.► +.a O I•30Y311©3dA1 AYPrA•111 MULLION LOADING MART A/AYIAIUAI DESIGN PRESSURE RATING 'W' (� f�ND CORRESPONDfNG MAXIMUM SPAN "'L"/Ff) FOR A C►VEN TYPE OF 11U EON AND MU //Oh' SpAGlhO /F} ) (USE MAXIMUM VALUES BETWEEN POSITIVE * NEGATIVE LOADS) ,�- 1117OINlM DOW TYF+E m MU Kw o a' x i• x 1/4' rime mutes © 4' r 4' x tM' TYPE' RJ L6,f1L,LW OO 4• x 4' r 1/4' Law ►� Mts1IQY Sn+CM MN AM SIAMW MU60N SMar+9 cJ=o• Ixm4' 4, to a' a' to 6' c4-0' 4, to a' S'TO 6' 0'TO a' c4-0' 4'M5' a'10 a' 6' TO 0' e' TO fe 10' To t 410 ON4W a•-0' 7'-6• a-11' 6'-e r1-4• ro'-a• 9-Il e'-o• is,-d• 14'-7• ,J'-d• r2'-s' re-7-tw-w 50.0 r-11, r-1^ 6=8' a-4• 1o=f1' 10=2• a•-7• 6•-d• 1s'-B' 14'-+' ,J'-J• rY'_0• f►'_Y• 10•_a• Sao 7-d• r-0' d-6' 6-f• ►0-7' 9'-to' D'-J' d•-a' 14'-d• 1J'-7• f2'-IO' f1'-d' 10'-f0• 60.0 Y-6` a-t0• 6'-4' S-►f' ,0'-J' 9'-9' a-0• e'-2' 14'-J• /J'�i' fY'-5" ►f'-4' f0'-e• 9'-f1' 66.0 7'-Y a-7' e'-2' 3'-9• f0'-0• 9'-4' a-9• r-If' ,J'-fl` 12-1f' fY'-2' f►'-0' ID'-J' 9'-a' 70.0 7-1• W-6• 6'-0• 5•-.r 9-a• 9•-,• a•-e' r-9` 11-7• ►2'-7' 1r'-f0' IO'-9• !0'-0' 9'-5' MO 6'-t1• W-4' W-10' s'-a' 9-7' 01-f0• 8'-4• 7'-7' ►J'-J' 12'-J• rf'-7• 10•-a' 9-9• p•_p• 80.0 e'-i0' 6'-2' a-9• 5'-5• 91-4' d•-d' d-Y' 7'-5• 1Y'-f}• r2'-0' If'-4, to-J' 9'-7' 9-0• e50 0'-a' a-r• J'-Y S.-J. 9•-2• 6'-6' Q-O' r-J• 12'-a' 1r-9• 11-P f0'-I• 9'-4' a-9' 90.0 a' -a' S'-tl' J'-e' 5'-2• 9'-0• d'-4• r-t0' 7-2' tr-s" 11'-r to'-I1, 9-„` M-2' d•-0• 950 61-5' S-lo' s'-5• a'-1• e'-ro• a'-2• 7-9' r-0 12'-r• tl'-4• to -a• 91-9• 91-0• d-J• 100.0 6'-4• 5'-9' 51-41 J=0' B'-e' d'-1' 7-7• e'-Ir• 12'-0• 111-2' ►o'-e 9-7• 81-10, E-1, rD50 61-3, 5=e• J-J' 4-tf• a' -a• 7-If• r-d• 6'-9• !r'-r0 t1'-0' f0•_4• 9-5- 110.0 0'-f' s'-7` J'-2' 4-►0 0-S' 7'-}e' 7'-4' a'-d' /f'-d' t0'-f0 10-91- 115.0 w-0• a-6• a' -I' 4-9• d'-J' r-a' 7'-J' 6'-7* rI'-6' f0•-e t0'-0' 91-11 - 120.0 5'-ft• 5'-5• a•-0• 4'-9• a-R' 7'-Y 7-2' 61-61 /1'-41 fo•-e• 91-If• 9-0• I- 125.0 5'-10• 5'-4' 41-11• 4-a' a-J' 7'-a' 7'-0' W-5* 11-2' 10'-4' r-9' a-t0• - - rJo.0 51-9• 5=J' 4'-rY• 4'-r r-lr 7'-5• a-1r• 61-0 11-a" 101-7• 9'-a• 8,-0• 1310 J•-9• 3'-2' 4-10• 4-a• . r-lo` r�1• 6-10' 6-s• to'-ir rtl'-f' 9-a• a-d• - - 14" J=a' 51-2• 4'-9• 4-5• r-G• 7'-Y• a' -a' S'-0• f0'-9• f0'-o• 9'-5• ®-4• - 145.0 s'-7• a'-t• 4-8' 4-/• r-e' T-Y 6-B• 6'-1• 10'-7' 9'-10• 9'-J• 7777 - 130.0 e'-e• J•-o' 4'-e' 4-J• r-r 71-01 e,-r 6-0• r0-5' 9'-9• 9' S• a-1• - - 1550 5-5' 4'-11' 4'-7' 4-r 7'-B' 7•-0• 6•-7' s'-fl' f0'-d' 9'-0' 9-f• 7-f1• - 160.0 s-r 4'- 1' 4-0• - 71-51 a-1r a -a• 5'-,0• ro'-0• a' Y 9-0• 7-ro• i G 1 . 1:a.41787; LCW : RM TO IMAMS ON SM MT 2 OF 19 N MULLION SPAM SING. or stuw ANT Awmw Sur sHw S1MLL NOr or ma rom ' Y-. FOR MWIDAM..ammisp W/ S7DRx4 81R5 • xnsnc N MOWON M%M SMUL fiC SUM ANT 94 MUM HEADER SPIN SNttL NOT HE SWEEOE0 W SMW &A SHIaa/O daft ME 5" ANT a Amm SUT SRN swt Nor EL' EK E0m B.C.