Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SUBMITTED PAPERS
DATE: 1: PERMIT NUMBI~t - PLANNING & DEVELOPMENT SERVICES DEPARTMENT - - — - BUILDING -&-CODE REGULATIONS DIVISION 2300 Virginia Avenue Fort Pierce, Fl. 34982 SCANNED (772) 462-1553 13 Sr. Lucie�,, APPLICATION FOR REPLACEMENT OF Vn[Y WINDOWS, SKYLIGHTS, DOORS & OVERHEAD GARAGE DOORS 1. LOCATION/SITE ADDRESS:�� _ c'%� 2. PARCEL ID NUMBER: o2.L O �5 f� i _ (� j '�'� Cj0 ®`` 3. DESCRIPTION OF PROJECT OR WORK ACTIVITY: Afmog e� -014Cv-, F 4. TYPE OF STRUCTURE: SFR 5. OWNERS INFORMATION Name: M j1 t4- p I i a..c- 3eill Address: 19 l(. A.2 ,y 3 St City: F" C toeelc--- State: F1 zip: 3 z/ 5f y 7 Phone: MOBILE HOME OTHER 6. CONTRACTOR'S INFORMATION FL Reg/Cert #: /5/7 County Cert #: 956 �C Business Name: EA f3 Phone Number: -�— ors Windows Swing o Skylights, ffiffie&Mss Opening Design Pressure A.S.C.E - 7 Design Pressure Product Manufacture Model # Method of Attachment # Florida Product Approval # 20 mph 30 mph 40 mph Windows & Skylights os re B SiGC . (�, i6 ` l/ - I I d Overhead Garage Doors < 30' - F.B.C. Table 1609.6 (1) + 1609.6 (2) B- Size C- Size 7. VALUE OF CONSTRUCTION: $ FEES DUE: RECEIPT: Ck owNws AFFmAvIT: I certify that all of the information contained in this application is correct and that all work will be done in compliance with all applicable laws regulating construction d zoning. PRINT QUALIFIERSIOWNERS NAME SIGNATURE OF QUALIFIERIOWNER STATE OF FLORIDA, COUNTY OF /� ACKNOWLEDGED BEFORE ME THIS DAY OF 0, BY -( IS "t l.U'PC"IiQIS PERSONALLY KNOWN TO ME OR WHO HAS PRODUCIDo L �i � 1�QS ID N7 CATION. 1 SIGNA OF NOTARY TYPE O R1NT NAME OF N ARY TITLE: NOTARY PUBLIC COMMISSION ANGELA M. HUFF ONMIS510N # EE 0835,90 NOTICE TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMI-. ST. LUCIE COUNTY Vinyl Siding TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT [] Attach•2 copies of the NOA or Florida approval with details to the product being used. INSTRUCTIONS Please complete all information in the space provided. All information must be Printed (use black or blue ink only) or Typed. This application for replacement of Windows, Skylights, Doors & Overhead doors to be used for only those activities that are not otherwise included under a primary building permit. This application for Permit may not be used for any activity that includes any type or kind of structural alteration. Building activities involving structural alteration, in addition to the replacement of Windows, Skylights, Doors & Overhead doors, must be permitted through the regular building permit review process. The information to be provided with this application includes: 1. LOCATION/SITE ADDRESS: ............................................. Indicate the street address, or general location, of the property on which the building activity is taking place. 2. PARCEL ID NUMBER:........................................................ Indicate the Property Tax Identification Number for the property on which the building activity is taking place. 3. DESCRIPTION OF PROJECTOR WORK ACTIVITY........ Briefly describe the building activityunder permit application. 4. OWNERS INFORMATION: ................................................. Indicate the name and address of the owner ofthe property on which the product is to be installed. 5. CONTRACTORS INFORMATION :.................................... Indicate the State of Florida (if applicable) and St. Lucie County contractors registration numbers, and the name of the business doing the work. 6. VALUE OF CONSTRUCTION :........................................... Indicate the total value of the work to take place. Total cost of construction includes all material and labor costs associated with the buildingteonstrtrction activity. -The value of tonstructio`n is used to determine the amount of permitting fees to be assessed. St. Lucie County reserves the right to question*and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction. All applications for Permits are to be submitted to the St. Lucie County Building and Zoning Department, St. Lucie County Administration Building, 2300 Virginia Avenue, Fort Pierce, FL 34982. All applications for Permits must be complete and filed with the Department no later 4:30 P.M. each business day. No applications will be accepted for processing after 4:30 P.M. For assistance in completing this application, please contact the St. Lucie County Building and Zoning Department, at (772) 462-1553, during regular, office hours (8:00 AM - 5.00 PM), Monday through Friday. Following the issuance of this Windows, Skylights, Doors & Overhead doors replacement Permit, the scheduling of all required inspections maybe made by calling (772) 462-1261. SLCCDV FORM NO: 006-05 --j*F1otida Building Code Online Page 1 of 2 BCIS Home Log In User Re Istration Hot To ics ! Submit Surchar e I Stats & Facts 9 9 P 9 Publications FBC Staff BCIS Site Ma Links Search P Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # �,,FKPRY1 lication Type!' Code Version 2007t+' 3 Application Status Approve Comments Archived A Product Manufacturer Plastpro Inc. / Nanya Plastics C rp. Address/Phone/Email 5200 W CENTURY BLVD. LOS ANGELES, CA 90045 (440)969-9773 Ext16 ronoconnell@plastproinc.com Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Ron O'Connell ronoconnell@plastproinc.com Exterior Doors Swinging Exterior Door Assemblies Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer M! Evaluation Report - Hardcopy Received Lyndon F. Schmidt PE-43409 National Accreditation and Management Institute 12/31/2012 Ryan J. King, P.E. �] Validation Checklist - Hardcopy Received FL4760 Rl COI CERT OF INDEPENDENCE.odf Standard Year ASTM E1886/E1996 2002 ASTM E330 2002 http://www.floridabuilding.org/pr/P _app_dtl.aspx?param=wGEVXQwtDgtQ8IrCmLmxsgjetlf7lU... 6/2/2011 Florida Building Code Online Page 2 of 2 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved mary of Products Method 1 Option D 10/03/2008 10/06/2008 10/19/2008 12/10/2008 FL # IlModel, Number or Name IlDescription 4760.1 a. Distinction Series Up to 3'0 x 6'8 Opaque Fiberglass Door "Impact" - Inswing or Outswing Limits of Use Installation Instructions Approved for use in HVHZ: No FL4760 R1 II INST 4760.1.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 4760.1 for Design Pressure Ratings, any FL4760 R1 AE EVAL 4760.1.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 4760.2 b. Distinction Series Up to 6'0 x 6'8 Opaque Fiberglass Door "Impact" - Inswing or Outswing Limits of Use Installation Instructions Approved for use in HVHZ: No FL4760 RI II INST 4760.2.1)df Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 4760.2 for Design Pressure Ratings, any FL4760 R1 AE EVAL 4760.2.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. Back Next Department of Community Affairs Florida Building Code Online Codes and Standards 2555 Shumard Oak Boulevard Tallahassee, Florida 32399-2100 (850) 487-1824, Fax (850) 414-8436 © 2000-2010 The State of Florida. All rights reserved. Privacy Statement I Copyright Statement I Accessibility Statement I Plug-in Software I Customer Service Survey I Contact Us Product Approval Accepts: W] W. eCE M w .F4'C;prltl'fl(y,"rR1CS" ViSP51gA i ,. Tuatstl � http://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgtQ8IrCmLmxsgj etlf7lU... 6/2/2011 r , I NAN YA PLA . C CORP. PIASTPR01 9 PEACH TREE HILL ROAD LIVINGSTON, NEW JERSEY 0 DISTINCTION SERIES OPAQUE FIBERG' ASS DOOR INSWING UTSWING rrI x _ ,GT' GENERAL NOTES f� 1. This product has been evaluated F'hd i?'n compliance with the 2007 Florida Building Code (FBC) structural requirements_excld g the "High Velocity Hurricane Zone" (HVHZ). "` e 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind bome debris protection this product complies with Section 1609.1.2 of the FBC and does not require an impact resistant covering. This product meets missile level'D" and includes Wind Zone 4 as defined in ASTM E1996. 4. For 2x stud framing construction, anchoring of these units shall be the some as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of this drawing require further engineering analysis by a licensed engineer or registered architect. TABLE OF CONTENTS SHEET # DESCRIPHON 1 Typical elevation, design pressures. & general notes 2 Door panel details 3 Horizontal cross sections 4 Vertical cross sections 5 Buck and frame anchoring - 2X buck masonry construction 6 Frame anchoring - I buck masonry construction 7 Bill of materials & components 37.50' MAX, OVERALL FRAME WIDTH N Z 0 w w j w O 0 g b m d INSWING x +65.0 -70.0 wry 09 02 E 82.00" N.T.S. 37.50" MG. an RR OUTSWING X +65.0 -65.0 arx, W. LFS 80.501, , g DRAN7NC NO. FL-4760. I SKEET I OF 7 K R:\A - Projects\Project Folders\pmj 650. 800\pf779\PF 779 R1\FL-4760.1\FL-4760.1.dwg, Model Y 79.25" MAX. DOOR PANEL HEIGHT N N ---I Is (D To o ZOD zvy N � 101 v .o �s o Z N� a t► I.59" o -►i �O 5*z a= NN O 0rn O � y � m A N O Z m a A N r pA Tl L I I N m v I�-1.59" z a "o r>:: 11.20" FFF------ I w '4z V '• rfl A NAN YA PLASTICS CORP. PLASiPRO INC. FlBERCLASS DOOR PART OR ASSEMBLY: DOOR PANEL DETAILS m 0 r�BUILOINO CONSULTANTS, INC. -1/1/ P.O. Bo: 230 Valrica FL 33595 VY Phone No.: 613.659.9197 Florida Boord of Protn�lonal Engln� m C...te O} Lharlxa/Uon N�o. gala 7 Lvndon F. Schmidt. P.E. No. 43409 2008 N.W. BUILDING CONSULTANTS INC. n,1n- n JMeJrIUJML rulanblyluJ oau- ouulplt/vier i/v hL1rL /ou.r.Vm-/ou.L.owg, moae i^l WIN WI1.7 1"MIN. FROM I" MIN. FROM -MASONRYEDGE MASONRY EDGE (TYP.) (TYP.) n Z a x 0 I• z 0 PC IF* r W W mp�x o•�f a a�c r- N„P �OcO �nvtn f� C, 2 8 ` _Z ° ° 2-1/2" MIN. FROM 2-1/2" MIN. FROM w> +�- MASONRY EDGE °MASONRY EDGE (TYP.) (TYP.) m A I" MIN. FROM 1"MIN, FROM -MASONRY EDGE MASONRY EDGE -►► V Z (TYP.) (TYP.) C.1 r i $ rn E ;Cj-Zt n�i m NOaQATE 1200E R.W. BDILDIND OCN9l1LTANT9 INC. NAN YA PLASTICS CORP. PLASTPRO INC. FIBERGLASS DOOR PART OR ASSEMBLY: HORIZONTAL CROSS SECTIONS VV BUILDING CONSULTANTS, INC. /I�P.O. Box 230 Voldco FL. 33595 vv Phone No.: 813.659.9197 FlerldD Boord f P faeelonal Engineers Certlflcate Of rizalion No. 9813 LTndon F. Sehmldt. P.E. No. 43409 lcA - Proleas\11ro3ect rolders\proj b5U - klUU\pr779\PF 779 R1\FL-4760.1\FL-4760.1.dwg, Model m � o0 1r o P A r— « CL� < m m v 5 H m > O 0 °z D- AW R p 0� o�ZZ .o. � A -C C) a W pe Im 0 i �n 70 z + c � O � n a O N P m .Z7 0', O O rn Q 1-1/4" MIN. EMB. (TYP.) 0 Z ° N Co p A N X m m 22 n o ^+ O v � (D � N VAJi�X� ° � 09c O Z .°�. �£O rFl c tNir� 0 Z a m3 °•°=Z m ° A A 0A o O xm m A °. .. n1. yy H J U3 fi oo 0 (: O � a one On , W N ° `mT a A �O oN � m3 fNm1 ' EMB. (TYP.) O Z ' N O � N O � S ,4 PRODUCT: Doeumente Prop,md W. P _ ? °2 NAN YA PLASTICS CORP. PLASTPRO INC. �p euaDlNo CONSULTANTS, INC. @ P.o. Ocx 23o valdoo FL 33593 I� 4� 0 2 FIBERGLASS DOORPnrne No.: e13.659.9197 n�i PART OR ASSEMBLY: $ o A i Fla lda Boord of Pr 1earonol Engtneen CortlOcote Ot Aut risatlon No. B013 Iv 1n VERTICAL CROSS SECTIONS ���'4/ gja.fg m NO DATE BY REVISIONS Lyndon F. Senmidt, P.E. No. 43409 ® 2DOB R.W. BUILD- Con eu�rnnrB Inc. d 0 • ,p • � � (((goon � m O O Z CS a 0n1O �= a O U N •; �o TYP. HEADM7 5 & JAMBS 6 TYP. HEAD -- SEE NOTE I -- & JAMBScli MASONRY7 MASONRY71 B z OPENING OPENING o X FRAME w aZ �w ¢w a: ZU 2X BUCK .� O = p 6 12z o EO 2X BUCKS w} En o U m e N - BUCK ANCHORING STRIKE JAMB FRAME ANCHORING HINGE JAMB O Masonry 2X buck construction vi NOTES: 1. I/4" Elco concrete screws anchoring 2x buck require a minimum I"clearance to masonry edges, a 1-114" minimum embedment and a minimum 4" clearance to adjacent concrete screws. Substitution of equal concrete screws from a different supplier may have different edge distance and center distance requirements. Concrete screw locations at the comers may be adjusted to maintain the minimum edge distance to mortarjoints. If concrete screw locations noted as "MAX. ON CENTER" must be adjusted to maintain the minimum edge distance to mortarjoints, additional concrete screws may be required to ensure the maximum on center dimension is not exceeded. LATCH & DEADBOLT DETAIL HINGE DETAIL e N.T.S. BY- RR BY: LFS 3 MG NO.: a FL-4760.1 c c T 5 or: 7 " 4 'v TYP. HEAD MASONRY OPENING FRAM 1X BUCK STRIKE JAMB FRAME ANCHORING Masonry I X buck construction I r I HINGE JAMB SEE NOTE I HINGE DETAIL LATCH 6 DEADBOLTDETAIL 2 2 NOTES: 1. 1/4" ITW concrete screws anchoring frame and/or sill require a minimum 2-1/2" clearance to masonry edges, a 1-1/4" minimum embedment and a minimum 3" clearance to adjacent concrete screws. Substitution of equal concrete screws from a different supplier may have different edge distance and center distance requirements. Concrete screw locations at the comers may be adjusted to maintain the minimum edge distance to mortarjoints. If concrete screw locations noted as "MAX. ON CENTER" must be adjusted to maintain the minimum edge distance to mortarjoints, additional concrete screws may be required to ensure the maximum on center dimension is not exceeded. 2. 3/16" ITW concrete screws anchoring frame and/or sill require a minimum 2-5/8" clearance to masonry edges, a 1-1/4" minimum embedment and a minimum 2-1/4" clearance to adjacent concrete screws unless otherwise noted by concrete screw manufacturer. E: N.T.S. BY: RR BY. LFS 3 V= No- FL-4760.1 c rr 6 of 7 BILL OF MATERIALS ITEM DESCRIPTION MATERIAL H 1 /4" X 3-1 /4" PFH ITW CONCRETE SCREW STEEL J 1 /4" X 3-3/4" PFH ITW CONCRETE SCREW STEEL K 3/16" X 3-1 /4" PFH ITW CONCRETE SCREW STEEL I MASONRY - 3,192 PSI MIN. CONCRETE CONFORMING TO ACI 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE 2 1 #9 X 3/4" PFH WOOD SCREW STEEL 3 2X BUCK SG >= 0.55 WOOD 4 1 /4" MAX. SHIM SPACE 5 1 /4" X 2-3/4" PFH ELCO CONCRETE SCREW STEEL 6 #8 X 2-1 /7' PFH WOOD SCREW STEEL 7 1 X BUCK SG >= 0.55 WOOD 8 DOOR PANEL 9 DOOR SKIN (MIN. 0.075" THICK) BY NAN YA FIBERGLASS 10 INSWING VINYL DOOR BOTTOM SWEEP BY ENDURA VINYL 10A VINYL DOOR BOTTOM SWEEP #3628 BY HOLM IND. VINYL 1 I REINFORCEMENT WOOD FOR LOCKS WOOD 12 FINGER JOINTED PINE FRAME. HEAD & HINGE JAMBS WOOD 13 #9 X 1" PFH WOOD SCREW STEEL 14 BOTTOM RAIL CELLULAR PVC 15 INSWING ADJUSTABLE THRESHOLD BY ENDURA ALUM. / WOOD 15A INSWING ADJUSTABLE THRESHOLD BY DLP ALUM. / WOOD 16 FORCE 5 WEATHER STRIPPING BY ENDURA FOAM 16A COMPRESSION WEATHER STRIP QLON 650 BY SCHLEGEL FOAM 17 KWIKSET KEYED ENTRY GRADE 2 STEEL 18 KWIKSET DEADBOLT GRADE 2 STEEL 19 CONTINUOUS LATCH AND HINGE STILE REINFORCEMENT WOOD 20 POLYURETHANE FOAM BY NAN YA POLYURETHANE 21 4" X 4" BUTT HINGE STEEL 22 #8 X 7' PFH WOOD SCREW STEEL 23 POLY FIBER JAMB COMP./ VINYL 24 # 10 X 7' PFH WOOD SCREW STEEL 25 TOP RAIL CELLULAR PVC 26 HINGE & LATCH STILE CELLULAR PVC 27 STRIKE PLATE STEEL 28 OUTSWING BUMP THRESHOLD ALUM./ 29 DEADBOLT PLATE STEEL 4.56"� N , �F-- 2.44" --{ 23 POLY FIBER JAMB 4.56" i1 ADJUSTABLE INSWING THRESHOLD ,2 11 F-- 244" —►f 12 4-916"JAMB fingerjoint pine 5.63" cq ��DJUSTAB[E INSWING THRESHOLD 4.56" N 1 N �ZOUTSWING BUMP THRESHOLD V .En 0 G� VZO Of O a c: o 0 ro —J+�7 � m 0 Sr., r. N.T.S. lom. BY. RR cxw ac LFS FL-4760.1 1 7 of 7