Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SUBMITTED PAPERS
a ' PLANNING & DEVELOPMENT SF_"''ICES DEPARTMENT . ® � BUILDING & CODE REGULi,-."IONS DIVISION m 2300 Virginia Avenue Fort Pierce, FL 34982 SCANNED 772-462-1553 By St. Lucie County APPLICATION FOR STORM SHUTTER PERMIT DATE: 5 - 2 4 - 2 011 PERMIT NUMBXR: 1. 2. 3. LOCATION/SITE ADDRESS: 6661 Nuevo Lagos, PARCEL ID NUMBER: 1306-500-0106-000 / 0 SECT TWP RNG MAP ZNG LU MIT TL+Qf'DTUTi/lt►i.AT, Un r% Y.1'T CUM•a7/1'UTz AClIrl v. nstall accorr1i-r)n Shiltt P_r.q to home (7) 4. TYPE OF STRUCTURE: SFR X 5. OWNER INFORMATION Name: Rowena Haag Address: 6661 Nuevo Lagos City: Fort Pierce State: FL Zip: 34951 Phone: 466-1345 Type of Surface attachment: Wood Frame ADDITION OTHER 6.. CONTRACTOR INFORMATION FL Reg/Cert#: S CC 13115 0 5 8 6 County Cert #: 2 5 5 8 4 Business Name: Master Craft Aluminum Proctuc=s Phone number: 3 3 5 -11 7 7 Concrete X Masonry Other Product Type Maximum Opening Pressure per A.S.C.E. 7 Product Compliance Report # Method of Attachment As per Product Approval or Engineers Analysis 120 mph 130 mph 140 mph 140 Exp. C FL N.O.A. Other Anchor Type Anchor Spacing ID -movable Panels ccordion see attached schedu e on U olonials then ALL PRODUCTS SHALL BE LABELED FOR DETERMINING IMPACT RESISTANCE -FROM WIND BORNE DEBRIS. **SEE FINAL INSPECTION PROCEDURE FOR. EXISTING RESIDENTIAL STRUCTURES ONBAC& 7. VALUE OF CONSTRUCTION: $ 3,000.00 FEES DUE: owNEws AFFIDAvrr: I certify that all of the information contained in this application is correct and that all work will be•done in compliance with all applicable laws regulating construction and zoning. Jeff Jackman PRINT NAME OF OWNER OR CONTRACTORIQUALWIER STATE OF FLORIDA, COUNTY OF St. Lucie SIGN O R OR CONTRACTOR/QUALIFIER ACKNOWLEDGED BEFORE ME THIS 2 4 th DAY OF` -May , 20-2,I BY - Jeff Jackman WHO IS PERSONALLY KNOWN TO ME OR WHO HAS /PRODUCED AS IDENTIFICATION. Sheryl D. Moore �aamoaaoaciaao.o.o.au...u..,•®wps�mP4�9�q'�a® SIGNA-/TUREO'F NOTARY TYPE OR PRINT NAME OF NOTARY SHERYL gt MOORE • - a, Comm# DD0749247 TITLE: NOTARY PUBLIC COMMISSIONNUMBER y,ywv o, Expires jp5/2012 SLCPDSD Revised 96/172010;�'Ko G`� Florida NotaryAssn., Inc Pmeammm.m aemmmemmmmmmmmmm. x....mm.. ■......i...� 06/06/2011 15/:19 7723?FaP60 PAGE 02/03 JOSEPH E. SMITH, CLERK OF THE CIRCUIT COURT Atti't:R RRCORDiNC-11 t1RA TO; SAINT LUCIE COUNTY Master Craft Aluminum Pro.ducts FILE# 36983al 06105/2011 ato3:0i om 34 SE Niemeyer C1>rC 1 e OR BOOK 3298 PAGE 2623 - 2623 Doc Type: NC RECORDING: $10.00 PSL I{L 34952 Pr MIT NUNRM: IlDb r- a 0-33 NOTICE OF CaRMENCEMENT The undersigned hereby given notice that improvemem will be, made m certain real property, and in aeeordanm with Chapter 713: Florida statutes the following infbrmation is provided in the Notice of commencement. 1. DESCRIP.TiON OF PROPERTY (Lcg-ul description and strcel address) TAX FOLIO NUN ER 13 0 6 — 5 0 0 — 010 6 — 0 0 0 0 SUi3DiYism SLEW BLOCK 41 TRACT LOT 4.._150G_-UMT 6661 Nuevo Lagos 2,G1EN.F�RALD.sCRjF71ONOF51PROVENIENT: install accordion shutters 3. OMrXER )INTORMAnON: a. Name Rowena Haag h.Address 666� Nuevo Lagos, fort Pierce FL 34951 c.interesli:iprpparq d. Name and address of fee simple titleholder (if other than owner) _-- 4.•C.ONTRACrOIz'S NAME, ADDRF-qS AND PI-IONE N1.lMBER: Master Craft A1ulnin-UM PrOd•ucts 1634 SF Niemeyer Circle PSL FL 34952 335-1177 5. SLIRETI" S NAME, ADDRESS AND PHONE NLTNO- UR AND DOND AMOUNT: .6. LENDEF'S NAME, ADDRESS AND P)(-IONE MIMBER: _ _- 7. Persons within the State of Florida designatcd•by Owner upon whom notices or other documents mdy be Served u provided by Section 7.13.1.3 (1)(a) 7.. Florida Star-utos: NAM& ADDRESS AND T11-10NE NU1V BEY3 : 8. In addition -to hiinself or herself Owner dcsignares the rollowing to rcccive a copy of the Lienor's Norim as prm ided in Section 713.13 (])(b). Florida Statutes: NAME, A,Dt)1zESS AND PHONE NIOMBERt _ 9. Txpiration dntc of notice of commoucement.(the expiration dote is 1 year from the date of recording unless a different date is specified) , 2() _Rowena Haag Homeowner Signature of Opmcr or Print Name and.Provide Signstory's TKIPJOfcc Owner's Authorized officer/Director/Partner/Manager . State of Florida Couety of,_, St . L7.t,cie The foregoing instrument was acknowledged before me this nth day of May , 2U� l t;y Rowena Haag -- . aS homeowner — (Printcd name of person signing above) (Type of authority,,. e.g. Owner, officer; trustee, attorney in fact) For self (Name of party on behalf of whom instrument -was cxccuted) Personal].), Known X or produced the following gyps of ID: ro•..■■■errM.■n■rr■arnrrr■■r■■■.■•■■r.■■� u ;j"3ri, OW7k-);W A Sheryl L, Moore (Printed Name of Notary Public) (Signature ofNo an, Public) (St ,l)#<c Eft�fl!u'� 4%1512012 MddBoxa Naterj A n� :InG, OR Under penalties of pet.iury, J declare that 1 have read the foregoing, and thni the facts in it ari�trtrt"ltr8th°tY 21'f"i4,y inowiedce and bciicf(section 92,525, Florida atatutcs)• Signatures) of Owner(s) or Owlncr(O' Authorized OtTicer/T)irector/Partner/MunAger wbo of„roed abovet Rowena Haag Homeowner nm orvaonoartAccurchnFt (Signatum) (Printed Name) Property Information F_ Building Information Owner: Rowena Haag Wind Zone: 130 MPH. Address: 6661 Nuevo Lagos Exposure Category: B Ft Pierce, Fl 34951 Minimum Building Dimension: 15 ft: -Mean Roof Height: 15 ft. Structure Category: H Design Pressure -Calculations Opening Location E�t 1� Device Device Device Max Positive Max Negative Number Zone Width (in) Height (in) Elevation (ft)— Pressure (psf) Pressure (psf) I Int 54 57 7 34.0 -37.0 2 Int 37 84 7 33.9 -37.0 3 Int 74 63 7 33.0 -36.0 4 Int . . ...... . . . . .................. 108 . ..... ... .. . . ..... .. . . . . . ........... . ....... ........................................ . .. 83 7 . ...................... 31.5 . . ........... . .... ...... -34.5 5 . . . ................... ... Int 38 . . .... ..... . ....................... . ............ . . . ............ . .... . . ................ 40 7 . . . . . ............ .. .................... 35.6 . ..... . ......... . . ..... . . . . -38.6 .......... 6 . . . ............................. Int . . . . .. ... 97 .............. .............. - - ------- ............. . .......... 82 7 . ....... ..... _ . ... . ............ 3.1.8 .. . .... . .. . .................. . ...... ____ -34.8 7 Int 54 . ....... . . ..... . ... _ ------------ 56 7 34.0 -37.0 in accordance with: ASCE 7-05, Section 6 - Wind Loads. Florida Building Code 2007 ed. Page 1 of 1 I D.r�Sd.& t$j > Application Detan FL # FL10753-R3 Application Type Revision Code Version 2007 Application Status Approved Comments Archived Product Manufacturer Town and Country Industries, Address/Phone/Email 400 West McNab Road Authorized Signature Technical Representative Address/Phone/Email Quality Assurance. Representative Address/Phone/Email Category Subcategory Compliance Method Ft. Lauderdale, FL 33309 (954)493-8551 tomj@tc-alum.com Tom.Johnston tomj@tc-alum.com Thomas B. Johnston 400 west McNab Rd. FxrL-auderdale,-FL-33309— (954)a970-9999 tomj@tc-alum.com Shutters Accordion Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Vladimir John Knezevich the Evaluation Report Florida License PE-10983 Quality Assurance Entity National Accreditation & Management Institute, Quality Assurance Contract Expiration Date 12/31/2011 Validated By ORLANDO L. BLANCO, P.E. Validation Checklist - Hardcopy Received Certificate of Independence FL10753 R3 COT 2010 Cgrtificate of Independence-FBC.pdf Referenced Standard and Year (of Standard) Standard Year ASTM E1886 2005 ASTM E1996 2005 ASTM E330 2002 TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 09/08/2010 Date Validated 10/19/2010 Date Pending FBC Approval 09/20/2010 Date Approved 10/24/2010 FL At Model, Number or Name Description 10753:1 6.8 Accordion Bi folding aluminum accordion shutter Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact. Resistant: Yes Design Pressure: N/A Other. See tables 1 and 3 on page 1 of 12 for design pressures vs span Installation Instructions FL10753 R3 lI 08-225 REV2.pdf Verified By: V. John Knezevich PE 10983 Created by Independent Third Party: Yes Evaluation Reports FL107S3 R3 AE 68 HVHZ Report 08.225 rev-2 pddf Created by Independent Third Party: Yes Back Next Department of Community Affairs Florida Building Code Online . . Codes and Standards 2555 Shumard Oak Boulevard Tallahassee, Floida 32399-2100 (850) 487-1824, Fax (850) 414-8436 © 2000.2010 The State of Florida, All tights reserved, Product Approval Accepts: WR Mezkja +zcttrittix�:rntt� nn0lon - Trvat.dOEM re..r • r A HVHZ L MANDATORY COMPLIANCE 1 ACCORDION SHUTTER SPAN SCHEDULE ASCE 7 HlmZ MOHz HVHZ DESIGN FM VE POSITIVE NT:GATTVE WAND WIND LOAD WLNDLOAO WIND LOAD LOAD WIIM YAM ALL UNIMATE @&@ CC MOUNTING O 0(31�31 ITIO D(p& 34 W L m64. L max. . L max. (P-,F.) (Fr -IN) (FT • IN) (FT- IN) A HVHZ L MANDATORY COMPLIANCE 2 MINIMUM SHUTTER SEPARATION FROM GLASS POSITIVE DESIGN LOAD Aar SNUTfER SPAN HIN. SEPARATION PRom GLASS ro[+ II61A1LAi1016 s 30'41' AumGRACE MIN. SEPARATON FROM GLASS FOR Nrs(AMATIORs , 30.9- ABOVE GRADE (W) (P-M3 M (M•IN) (1!N. ) (IN.) 29'3 13-0 3.314 3:•3/8 310 5-0 3 1 873 21111 1.710 1D-0 2-1/4 1-3/4 12.1E 3-3/4 3.47 50.0 S-0 3 1-I/8 0 2.1/4 1.5/8 0•0 1 2-114 . 2 II-S 3.314 3•lA 70.0 s-0 3 1•ue 7.0 ] 1•ux 0.3 2.1/9 1-3/1 10.6 3.314 - 3.1/2 - 90.0 so 3 1-ue 7.0 B•3 3 2.1J9 1-Wa 1.1/4 9,10 31/2 3.1/2 110.0 S-0 3 1-114 09 3 J-3/8 8-3 24/2 2.1/2 9-I 3.114 3.1/4 110.0 5-0 3 1.114 J•0 3 1.3/4 8.3 • 18 23/8 8.9 3 3 HVHZ-(TABLES 1 & 2 ONLY) TABLE NOTES: ~ �W� au N r HURRICANE PROTECTION L LMNZ: DEFINED AS MIAMI.OIDE COUHIY AND BROWARD COUNTY FLORIDA. 2. WINO LOADS: DETERMINE POSITIVE AND NEGATIVE WIND LOAD FROM AXE 7. 3.2A_N: IN TABLE I, ENTER POSITIVE AND OEGATTVE WIND LOADS AND READ ACROSS TO THE APPROPRIATE COLUMN TO DETERMINE 14AR. SHUTTER SPAN (BLADE li0!�:M). 4.REVERSWM,: THE 6.8 SYSTEM MAY BE MOUNTED WITH THE INSIDB AND OUTSIDE OF THE SHU'02" BEING REVERSED. FOR E%AMPLE: IT NS PER4ISSI8IE TO MOUNT ON THE INSIDE OF A WOOD OR CONCRETE REAM VRTH THE MCR LIE ME SLAT FACING OUTWARD, FOR THIS CONDITION YOU MUST E.N%RETHAT ME SPANS IN TIEAPPROPRIATE POSITIVE COLUMN OF TABLE 1 ARE AP7UEO IN THE DIRECTION TOWARDS THE HOST STRUCTURE AND THE SPANS 1N 711E NEGATIVE COLUMN OF TABLE 1 ARE APPLIED IN ME DIRECTION AWAY FROM ME HOST STRUCTURE. S. SEPARATION T S; DETERMINE SEPARATION FROM GLASS VALUE IN TABLE 2 WMI ME APPROPRIATE POSITIVE LOAD AND SHUTTER SPAN. &FOR DESIGN WIND LOADS BETWEEN TASWTED VALUES, USE LINEAR INTERPOLATION 70 DETERMINE SPANS AND SEPARATION FILM GLASS, EXCEPT FOR LESS THAN 30 FT. WHERE INTERPOLATION IS NOT ALLOWED AND THE NEXT ANGRIER LOAD MUST BE USED. Win aril_fnHPtry\08.22SWR bl38.22S.UI^,9, 9.ON2010 1:25;11 PM• 11 x 17. 1 ON-HVHZ & E ASTM Wind Zone 4 I 1 ACCORDION SHUTTER _ SPAN SCHEDULE A91E7 POSITIVE 6, DESIGN NEGATIVE WAND WVINDLOA.DALL LOAD MOUNTING I' OMIDITIONS W L-, (P.sI) IF(. IN) ) 3JS.0 8-L1 120.0 6-9 125.0 8-6 i 130.0 8.4 135.0 &3 140.0 7-11 145.0 7.8 150.0 7.5 155.0 7.2 160.0 6-11 16S.0 6.9 ' 170.0 6-6 175.0 150.0 6-2 585.0 SO 190.0 5-10 195.0 5-8 NON-HVHZ ASTM Wind Zone 4 - ONLY MINIMUM SHUTTER SEPARATION FROM OL655 POSITIVE CFSIGN LOAD ncTm %URTEA SPAN HUI. SEPARATION FROM GLASS FOR INSTALLATIONS S W-W ADOVEGRADE IlMSEPAPATION FROM GLASS FOR INSTALLATIONS > 30-0• ABOVEGNADE (P.S.F•) IF • IN) -_ (IN.) ON.) S-0 3 1 390 8.3 2,114 1.3 1" - 1.1 4 1.3 4 !3-0 3.34 bf 2 3 1.1. 40.0 E'7 2.14 1- 7 4-0 _ 2-U4 1-314 109 2.1 4 2.18 11-0 3.314 Z-516 I30 4.10 4-114 S-0 1 1-i•8 8-3 - 2•1/4 1-5/8 so 2.1/4 2 50.0 10O 2.3/e 2318 LL9 1.314 3-T78 1"" 5.313 5.1/8 5 0 3 L-IAT Eo.o 6 s 2.1/4 1.314 9.0 2•U4 2.119 1" 2.3)4 2,314 12m4 S S So 3 1.118 7D0 7.0 2.114 1-112 9-3 ZIA 131E 11.5 4112 i•112 5-0 3 119 90.0 7.0 2414 83 2.1/4 2•1/4 10-7 3.3/4 3-7118 50 - 3 L•1/4 110.0 70 7.1)4 1.3/4 r13 2.1/2 24/2 1208..-.......2-sis._.__..-.. To _ 2•t14 �_ I-j14 L......................... l_.___..-.._,......... 4.RPJERS7NG: TIRE 6.8 SISIIN MAY BE MOUNTED WITH THE INSIDE ANU OUTSIDE OF TINE SNUTIL'R BEING REVERSED. FOR EJ:AMMPIE! IT 15 PERMISSIBLE TO MOUNT ON THE INSIDE OF A WOOD OR CONCRETE SAM W[TH THE BACK OF THB SLAT FACING OUTWARD. FOR THIS COLO17 1 IN NON-HVHZ & ASXM WIND ZONE 4 ASTH V+IID ZOM 4, USE TIE APPROPRIATE POSITIVE IOADJN I1We TABLES 9 & A ONLY TABLE NOTES Lora AND 5NUMR SPANS IN M_ APPROPRIATE FosnTVe La iM OF TALLt 4. 1, NON- me DEFINED AS ALL, LOCATIONS OTHER TI WI MIALI-CAOE 5._=. 1 907o G-LA (TATRE 2 a 4) IS HOT REQ.RRED IN 1WIFm 2�t+�'l COUNTY Arm DRavaaD CaA+ FWRIM 11 RU 3 (NO HMI W00 SPEED OR LESS). SEPARATION FROM 6LA 8LE, i IS REQUIRED FOR WIND ZONE 4 (141 MPH OR GREATER WIND 2. WIND : DETERMINE WE AWD NEGATIVE WIND LOANS FROM ENTER TABLE 4 WITH THE DESIGN POSITIVE LOAD AND READ AQI AS+F 7. THE SEPARATION FROM GLASS VALUE IN COLUMNS 1 OR 2 (WTlIONEVFh'TB 3.SPAN1 IN TABLE % ENTER N LIVE WIND LOAD ORLY, DETERMINED APPROPRIATE), '• FROM ASM 7, THEN MOVE ACROSS TO SELECT THE ALLOWABLE $.FOR DESIGN WINO LOADS BETWEEN TABULATED VALUES, USE THE NEXT SHUTTER SPAN (BLADE LEHIGHER LOAD OR USE LINEAR INTERPOLATION TO DETERMINE ALLOWABLE SHUTTER SPAN, 910 4" }: Y 1 08.225 1 1 ! GENERAL NOTES: 1, THESE EVALUATION DOCUMENTS REPRESENT A SHUTTER 9YSTEI4 ANALYZED WITH THE PROVISION SET FOR THE ISSUANCE OF A FLORIDA BUILDING CODE PRODUCT APPROVAL, FOR THE HIGH VELOCITY HURRICANE ZONE (HVHZ) & NON -HIGH VELOCITY HURRICANE ZONE (NON-HVHZ). 2. THIS SYSTEM HAS BEEN TESTED AND EVALUATED AND IS IN COMPLIANCE WITH THE INTERNATIONAL BUILDING CODE (IBC) AND THE INTERNATIONAL RESIDENTIAL CODE (IRC). 3. NO INCREASE IN ALLOWABLE STRESS HAS BEEN USED IN THE DESIGN OF THESE PRODUCTS. WIND LOAD DURATION FACTOR Cd = 1.6 WAS USED FOR WOOD LAG SCREW DESIGN. 4. THIS SYSTEM HAS BEEN TESTED AND EVALUATED AND IS IN COMPLIANCE WITH THE FLORIDA BUILDING CODE (FBC) REQUIREMENTS, INCLUDING THE HIGH VELOCITY HURRICANE ZONE (INHZ). THIS SYSTEM MEET$ MISSILE LEVEL "WAND INCLUDES WIND ZONE 4 AS DEFINED IN ASTM E1996-05, 5. TESTING WAS CONDUCTED IN ACCORDANCE WITH TAS 20112021203 AND ASTM E1686.0S/E1996-05/E330-02. 6, DETERMINE THE POSITIVE AND NEGATIVE DESIGN LOADS TO USE WHEN REFERENCING THESE DOCUMENTS IN ACCORDANCE WITH THE GOVERNING CODE AND GOVERNING WIND VELOCITY. FOR WIND LOAD CALCULATIONS IN ACCORDANCE WITH ASCE 7, A DIRECTIONALITY FACTOR OF Kd =0.85 SHALL BE USED. 7. THESE APPROVAL DOCUMENTS ARE GENERIC AND DO NOT INCLUDE INFORMATION FOR SITE -SPECIFIC APPLICATION OF THIS SHUTTER SYSTEM. 8. USE OF THESE APPROVAL DOCUMENTS SMALL COMPLY WITH CHAPTER 61GIS-Z3 OF THE FLORIDA ADMINISTRATIVE CODE. 9. THESE APPROVAL DOCUMENTS ARE SUITABLE TO BE APPLIED BYTHE CONTRACTOR PROVIDED THE CONTRACTOR DOES NOT DEVIATE FROM THE CONDITIONS DETAILED HEREIN AND THE CONTRACTOR VERIFIES THAT THE EXISTING STRUCTURE DOES NOT DEVIATE IN EITHER FORM OR MATERIAL FROM THE STRUCTURAL SUBSTRATES DETAILED HEREIN. 10.ANY MODIFICATIONS OR ADDITIONS TO THESE APPROVAL OOCUMENTS WILL VOID THE APPROVAL DOCUMENTS. I LWHEN THE SHE CONDITIONS DEVIATE FROM THESE APPROVAL DOCUMENTS, THE BUILDING OFFICIAL MAY REQUIRE THAT SHE SPECIFIC DOCUMENTS BE PREPARED, SIGNED, DATED AND SEALED BY A LICENSED ENGINEER OR REGISTERED ARCHITECT, WHICH DETAIL AND JUSTIFY THE DEVIATION,. AS A CONDITION TO THE BUILDING OFFICIAL GRANTING HIS/HER APPROVAL 12. EACH SHUTTER ASSEMBLY SHALL BE PERMANENTLY LABELED WITH THE FOLLOWING MINIMUM INFORMATION: TOWN &COUNTRY IND. FORT LAUDERDALE, FL. MISSILE -D- - ASTM EI86E, E1996 & E330 TAS 201,202 & 203 FLORIDA BUILDING CODE APPROVED 13.ALL EXTRUSIONS SHOWN SHALL BE 606346 ALUMINUM ALLOY, U.O.N., WITH A MINIMUM Fy OF 20 KS.I. 14.ALL BOLTS AND WASHERS (EXCLUDING INSTALLATION) SMALL BE STAINLESS STEEL WITH A MINIMUM TENSILE STRENGTH OF 60 K.SA., U.O.N. POP RIVETS SHALL BE I/4'A OR 3/16.0 $052 ALUM. ALLOY. IS.ALL SHUTTERS SHALL HAVE A LOCKING MECHANISM CONSISTING OF THUMBSCREW, PUSH LOCK OR BOX LOCK AT CENTER OR SIDE CLOSURE. 16.TOP AND BOTTOM OETATLS MAY BE INTERCHANGED AS FIELD CONDITIONS REQUIRE. SEE PAGE S FOR LOCK LOCATIONS AND DETAILS, 17. FLOOR TRACKS MAY BE REMOVABLE AT NQY-STACKING LOCATIONS. USE REMOVABLE ANCHORS. 18,THE ACCORDION SHUTTERS MAY BE MOUNTED WITH THE INSIDE AND OUTSIDE OF SHUTTER BEING REVERSED. FOR EXAMPLE: IT IS PERMISSIBLE TO MOUNT EXTRUSIONS ON INSIDE OF WOOD OR CONCRETE BEAM WITH BACK OF SHUTTER FACING OUTSIDE (SEE PAGE 5 - TYPICAL PLAN VIEW). 19. DETAIL S to 12, 16 & 27 on page 3 to 4, MAY BE BENT TO FORMA CURVE WITH A MIN. RADIUS OF 10'. 20. ALL DIMENSIONS SHOWN INCLUDE POWDER COATING FINISH. LOCKING ME TYPICAL SECTION SE TYPICAL ACCORDION SHUTTER ELEVATION N.T.S. TOP TRACK PLAN VIEW BOTTOM TRACK 1 08-225 1 4.874' KINK .0684 2.782" -.I25u"7 .100" 1•.• 708" 7.82150'•0" _ .__ 1t3'-('j' �.19 S" j1j1I.' ...v0...:..61.9700.TG.' 95'•$ .143" _.9 �7'�t.821 .099' 143fe25" 06643" 11..79088' it 1 In .0r m t. L 'Na V�'1.0686 .095" .06O .6 2 200106'a Y���� y 09LO" 20I 1.510' 0062" 97. ,6309' �.066 1 9081.250" 9 ,05m 1271" �M•*P4S z9 2282" 1 It1,1 ) ;14 11 5.745" MAX. 3.610" V W54 :2) BUILD OUT WALL HEAVY 2-LEG WALL LITE _-LEG WALL /� HEAVY HEADER/SILL oa 2 SCALE: HALF SIZE (� O LJ 0 LITE HEADER/SILL W �N SCALE: HALF SIZE SCALE; HALP SIZE SCALE: HALF SIZE SCALE: I1ALf- SIZE yd, WHERE SHOWN SCREW BOSSES & FELT GROVES ARE OPTI o NAL ON ALL EXTRUSIONS z nF? 2.655' �l 1.825' 8i5_„ 2,195' 2.9oo•• }{-.250'• L S10" O7 SILL SILL ADAPTER SCALE: HALF SIZE SCALE: HALF SIZE i; G.603" 30, 225 �tL•' 4 1L0" Z. 325' .258" .297" I .06 .150R .030R ,05L" .0 2" 1.625" .069" 13 TYP•.Si6T�SL`A (!_BLADE T 7 6 B�STARITERi►�iI SC9L'EBNAL'FS1ZE_7t SC'A!'�EaHAlE45l2E ,190 4. 0" L.102" .227" _� .osc•• _ Ig 6.8 STACK /CONECTOR SLAT/BLADE 105 SCALE: HALF SIZE 2.195' OEXTENDED SILL_ SCALE: HALF SIZE �¢ CEILING HEADER/SILL SCALE: HALF SIZE NiG "w'-1. 2.G55' 2.365' vt 510' .460' ni ;TYP IN o�- .1�060'�I O e .____...-- 4.510' ----•_ - 2.195' !- 4.510' -F a DIO EXTENDED SILL AD FTOR MID SILL 12 MID SILL ADAPTOR SCALE. HALF SIZE I SCALE: HALF SIZE SCALE: HALF SIZE 0 R1 SC o.oeo' mc. eAi 1-1 420' WALL SILL CLIP SCALE. HALF SIZE k. LA!,cr:��..1 hl u 5EP 06 2010.1. r• 08 225 snect 3 a 12 I g MAX: _..-. SCALE, N.ALF SIZE 3't5m PAIR' 010-24 THUMB Sln. SCREWS z Ir 3 w .062' ¢ a 201 RECESS SILL FOR USE WITH SCALE, HALF SIZE 0 AND ® ONLY 2T SLIOE ROD SCALEe HALF SIZE 1812755"" 1 VARIES j-� .3375' WHERE LOCK PINS ARE USED, THEY ARE ENCACEO IN .THE STACKED POSITION & AREN'T REQ•D IN THE CLOSED POSITON. 25 OPTIONAL ALUMINUM OR PVC LOCK PIN FOR 29A+298 SCALE, HALF SIZE 357• R 76' .062'. Er .194' 26 80X CENTER INSERT SCALE' HALF SIZE .6?3' .236' 1�. . LNO• 1.710' .443' 443 1AA4' m n •D90' a' 4 :. ^. In .284 m - m mo :26• 1.068' .496' 1 •n v1 e 3.443' N 4. 3.476' _ .160't. i )AOE_ .,062' gb 2003 6.8 CENTER MATE gp,UNIMATE.LOC 31 MALE BOX CENTER SCALE: HALF STYE ,.oCALE:'HACF SIZE SCALE, HALF SIZE SSW' x 13/16' WIDE i---t A00' 1 D> jD YP, EE LL11 !L, SECTION A INbL�S140 ESYS7E S BOX LOCK SCALE- HALF SIZE POWDER COATED, ZINC OIE-CAST O36 �Iffi�K ADAP ER (OP710NAL) SCALE: HALF SIZE 4MYLOIJ ESSTEEL BLYOLE.DSO'"WHEEL L 0" TYP, AT EVERY OTHER INSIDE JOINT AT TOP, .'i.A:_ 22 t20LLER�ASSEMBLY SCALE:MALF SIZE t-{ .250' 4+1'7SS• SRO. w' b K'i• 2.750' 27 RAINGUARO SCALEe HALF SIZE. 32 FEMALE BOX CENTER SCALE, HALF SIZE STEE0NUi"INIESS-T SO 1 • 1 4-20.1 OR 5 M CHINE SCREW S/16-0 INTERNAL STEEL THREAD 37 T'-SCREW INSERT SCALE, FULL SIZE 1.950•, -{ '�-•t'28P I NYLON WASHER w t rn I - OR ALUMINUM 'E••• (NYLON BUSHING � G Nlu, OPTIONAL) •0i� ` I4 x T.-3/4" L10 HT S.S. '•INSERTS SCREW W/ '3--------- I---••--• INTO TC ULTRACOTE COATING 750" TRACK ITYP TOp b BOTTOM) 070" YION BUSHING W/ WASHER: CYLOIDER•SOUO BRASS, IOENEL PLATED 1/16"9 x 1/2" P INTERIOR JOINT TOP MtrJSwGdR:C DICAST P06T1lR COATED VIVO A 7•' INTERIOR JOINT BOTTOM EITHER CAN E USED 0 EXTERIOR IE: MAY BE KEY OPERATED Wf510E OR IMJHBUSyING..AVe rAIL RH OFEMTEO RtSWF. 7.4 �.ssEIM -SCALE) N.ALF SI2E 2 IBRASSP.U'SH LOCK SCALEi HALF`512E 4.000' .SBo• ' ro . - .224' 28 OECORAT}VEbFL00R TRACK SGAt!EINAIIF 517,CT�T«S L 33 OUTSIDE CENTER MATE SCALE, HALF SIZE HEAD STYLE VARIES THUMB SCREW SCALE, FULL SIZE 39 2X7 ANGLE SCALE: HALF SIZE 1.040.443 - 1.443 8' .. . }—} ,568' N 3A44' g OLD 6.8 CENTER MATE SCALE- HALF SIZE 662"• 2 40 Z.21G' M1 j J as0 1zs �_ m' h .190' .125" 34 fNSiDE CENTER MALE SCALE,HALF SIZE •`1,C1. ` •i3 P4040b 4;Oc �i>�e = 2" k 3" EXV` SCALE, HALF SIZE 2! z a• q tY N7 " f 1 i i 1 it !L to SEP O (00 r, • LO�CD „ 1`lIOSi�k2W8 08-225 1-1/2" MIN. FOR CONCRETE STENER (b 18" O.C. EXISTING GLASS R BLOCK AND 3/4"- MIN' SF. ANY ANCHOR SHOWN F :vOOD ANCHOR SCHEDULEI. EXISTING GLASS 'a g Al T. 01R CTION I SILL (INSIDE) 17g' INSIDE BACK) OF ANGL LEG 17 t . 0.053" 'THICK 5063- 16 A UM. ANGLE T' x 1' MIN. 0 £i•,'+ �i 0 2" x S" MAX. (ANGLE LEG _ $$i 9 9 AY BE REVERSED) 3___. 9 rEHt''R 13 13 13 (1'7S ANY ANCHOFIiSIJO W(�-'=—`"- -- •W 13 rr( aft) .1g IMJANPH()RCHEDUI. E)� 701 5 2 ..02E �. 6.80"('TYP.) 9 S M12x 1/2"GALVANIZED BOTTOM 1/1-20 THUMBSCREW (OUTSIDE) -- t , ) OR S.S. SMS, 3/16"0 ALUM INTO CENTERMATES 1/3 U-m ! I-1/2" MIN. FOR CONCRETE OUTSIDE -FRONT I/4 -2Ox1 THUMBSCREW INTO PUP RIVET UR 1/4-20 TO 2/3 SHUTTER SPAN $ OR BLOCK AND 3/4" rIIN. THREADED HOLE. LOCATED Ca MACHINE BOLT 8 NUT MV el FOR WOOD 1/3 SPAN TO 2/3 SPAN FROM L ,B" O.C. MULTIPLE SHUTTER ASSEMBLY TYPICAL PLAN VIEW BOTTOM OF SHUTTER FOR BLADES SCALE: 3" = 1'-0" N a Jd SCALE: 3" = i'-0" 58-3". USE TWO THUMBSCREWS ON BLADES > W-3•'. ONE P) 1/3 SPAN LACKING DETAIL$ FOR '1• V AN O 014E AT 2/3 SPAN FROM BOTTOM CENTE MATES L,II USE 11J BRASS PUSH LOCK OF BLADE, TYPICAL. FOR LOCKING SHOWN O�J RANDOM OR (1 S/16-1Q THUMB SHUTTERS. A BRASS PUSH LOCK Q f g SCREW VAN THREADED MAY BE SUBSTITUTED DET Il5 7_ (_+( INSERT 3 AT7/3SPAM �/ SEE END STRPS(IIEOUE Y „R 70 2/3 AN FROM Ut BOTTOM OF SHUTTER 30 '�I FOR MAX. SPAR FiIEN ' 13�- USING 001, (ODOR COT' -y�bt •{ ENO STRIP SCIIED11E (40oUSr APPROPRIATE ._ STARTER STRIP TO f..D/D f2.1y AOp I''\SIJWLNO CONO TIOJS. It 1 ` t!E 16.1 I FASTEN STARTER (INSIDE) rD o (.1- _ mpg q STRIP TO TRACK W/ eT 867 2/M 10 SCREWS 3 e/i/o��u..r• �Z .-_gb.T _ ALTERNATE END STRIP DETAIL AT CORNER. 13yt3 I I C7 q q0O SCALE, 3" a 1'-o" ANY TRACK W/SCREW 33 a BOSSES. o POR GREATER 111D 5 OR LCA05 ft 7.111511 o) 1 I I I � C{� 1.9LE100vP.EUSINO -4nANC" ON a0'Cun "f 6NQLE MDSPAN U SIkO I!If ANCHOR CN IT' Q`p WQ SILL S I 10 run LE I nIL, )rt' Tllf 3[gEr, OA 1IL.]Of00tt �•�F� I 1 1 1D rem slam 0 1 ) Q Z EXISTING GLASS n ��iE ' i 13 USE (11 BRASS PUSH LOCK /I USE TI BRA55 PUSH LOCK-- > OR 113 5/1540 THUMB 73 y q Sq (/� 5/15-t8 THUMB (INSIDE) SCREW 1 0 71IREADED 30 2 S[REW I 0 THREADED To 2 T 77) AT v3 SVAN (4 'g `� INSERT M A'f 1/3 SP.AN ll ay! ' I TO 2/3 SAAN FROM d C �`E�i' P TO 213 . AN MUOM DOTTOM OF SHUTTER (OUTSIDE) C BOTTOM OF S t`,.. 1!'Jil' t ,• r S 1 23 ..__._._......__..... ___..._....._...............__._..__._._._...._..__..__ `1` 1, T' J. UCCt TYPICAL OUTSIDE CORNER CLOSURE DETAILS WO/CORNER POST NTS 13 T6 J fL m /u 13 \ SILL 31 ��- 15 13 23 (DUTSIOE) '+• `w � v. -. IL USE (1) BOX LOCK AT 1/3 20 �:• ,alt - SPAN TD 2/3 SPAN FROM P, •. SEP 06 2010„ . BOTTOM OF SHUTTER J'� �•+Z. OTYPICAL INSIDE CORNER CLOSURE CC2 DETAILS WO/CORNER POST g�3 MULTIPLE SHUTTER ASSEMBLY )+: •:.,)L(!Os}is.wae NTS ...(�, ��{!?. SCALE• 3" = T_0.• 08-225 Ilea sa12 proJ6:ts\MiDllyrAt �CADSVJWttEMdt\CAD2000�TPwn D� (bunt.y\08-225\R2s17t0&I25-051fw, gf06/70101:75:32 P(A. 11 z 17, t:l. rn•w.M�reiP_avn I CI CINJNECiI TYPE -- REFERENCE A CHOP Ll SCHEDULE FO MAXSPACING 2 FASTENERS ALUM. TUBE -EACH ANGLE 8063-T0 ALLOY SEE TARIF A FOR SIZE. ------ x2"zl/8"I, ••ALTERNATE 711RU BOLT OR 2' x 2" x 1/8" Cl CONNECTION TYPE FM ALUM ANGLE P REFf. RENCF. ANCHOR SCHEDULE FOR MAX � THREE 3/16"0 ALUM. o 1� 1 •• 1 1 SPACING _ 4 POP RIVETS OR -- rL---- -- --1GLA S THREE kit SMS, TYP. 17 - -IAJ — —� ,� ` OR DOOR ' r01 TABLE A (Cc3) PRESSURE VS ALLOWABLE LDlGItH) PSF rNO L9O O(liToYB/08• 62 - n— 9'-B' 17•a• ez 92 4S 11�LL• 102 ew• n•-r 110 -9• 17•11• 1 r-r ea•r 3116 RIVET OR 1112 51• (0 10" O.C. OR 1/4- NUT A. BOLT (TYF ALUM. TUBE 6063-T6 ALLOY SEE TABLE B FOR SIZE. V x 2" x .093" 6063-76 ALUM. ANGLE. TYP. 3/16-0 ALUM. POP�� bpi 17 RIVET OR 1112 SMS 11 1 I @ 10" O.C. (TVP.1 MAY USE MALE OR FEMALE LOCK -SLAT) W o 13 ALTERNATE THAU BOLT C2 CONNECTION TYPE CC,3 TYPICAL CORNCLCl ER OSURE DETAILS REFERENCE ANCHOR RE CORENCEIPNC'iORYPE C- N7$ SCHEDULE FOR MAX, SCHE DVLE FOR I?AX. ..�_ d 1• TABLE B Kcal MIEM''RE VS ALLOWARE IEA'GTK PSF VNI1 to wmi 1d.0 62 6'•r 2-4• 72 r-10- ll•-r al na ll•r 9z 102 7=r laaa' A W 6'•T 9'-11' 9'•2' S •T B'•1 yz� 3/16-0 ALUM POP RIVET OR 1,12 SMS (A Is--O.C. (I'YP.) 2 FASTENERS EACH ANGLE THREE 3/16'0 ALUM. POP RIVETS OR 17 THREE 412 SMS, TYP. 1" x 2" x 7/9" OP 2" x 2- x 1/0- ALUM .ANGLE USE MALE OR FEMALE LOCK -SLAT) EXISTING CONC BLOCK OR WOOD FIR, 1-1/2- MCcIN. FOR CONCRETE FUR WONDANO 3/L" MIN. fASTENER @ 10" O.C. (USE ANY ANCHOR SHOWN IN ANCHOR SCHEDULE).- -2'x2' x .090" 6063-T6 ALUM TUBE TYP. •2"xS- x1/B•' x CON INUOUS ' ALUMINUM ANGLE OPTIONAL ANGLE ORIENTATION TYP. CC) TYPICAL CORNER CLOSURE DETAILS 1)12 x 1/2" GALVgNIZF.O (OU HIS OR S.S. SMS. 3/16"0 ALUId. POP RIVET, OR 1/4-20 MACHINE BOLT & NUT SIDE CLOSURE OPTIONS to10" O.C. SCALE: 3- KD[1Fa1x1e.-CAD1WKn &dchTCAD20081Twm onA-CXUnIry108.225TRZ�b108.225-06.Mg,9i0N20101:2S:36P61, 11 x 17, 1:I, www.PLTMpmnM_mm 114-20 MACHINE DOLT W/NUT @ 12" O.C. OR NIL SMS (O 6- O.C. ITYP• TOP & BOTTOM) WASHER IrYP.I ILx314" SMS LO 9" O.C. \ ANGLE TO TUBE CONNECTION 2" 2'• x .125'• EObx3-T5 ALUH. TUBE N TY NECTIOPE 'NCE ANCHOR 1LE FOR MAX. G O ALTERNATE BUILD OUT MOUNT SECTION Jrii• A U �` 05e5-so Vi r w 08-225 pJ _7 GLASS OR DOOR-- ° Cf w°WMmi}- GLASS FOR 6.SW F u++� OR DOOR •-- SEC THE 4 B FOR IINJI 1CH NU @ 12 BOLT OR LOCK NUT Cd 1T" O.C. OR SEC TME2 TCR 42L XtON�IMx ¢ i w o K z ¢ ° II 12 x 1/2" SMS 12" C.C. ALUM. q1T x 1/2" SMS 0Y 12- O.C. E.S. �� TO tx T'0 ' . E h V 0 ti = OR 3/16"0 POP 'C OR 3/16• 0 ALUM -POP w 0 RIVETS 6" OR211 ALUM. @ 6" B.C. RIVETS 9 6" O.C. E.S. \ ~ x IVETS OR 1/4"d ALUM. POP RIVETS / 14 Q1 AND ((0 12" O.C. E.S. Q9 ANDOO 1/4" MAX. PROM PIN GUIDE TO SHIN. ASSEMBLY IRtlCI ' Cl CONNECTION TYPE r 'a REFERENCE. ANCHOR 0Qwm o SCHEDULE FOR MAX SPACING KZ ZM w r STRUC Y WASHER (TP,1 ASSEMBLY ' WASHER ITYP.) WA / 1/2" 112" TVP. EXISTING CONCRETE, �_ff/MDIS li GLASS---lU{,I+ 'CcE TA9(E 2 ^�BLOCK OR WOOD FRAMING 4 C. NECDON TYPE OR DOOR FOR WN. EFERENCE ANCHOR SF➢ARAMtI W - — C3 CONNECTION TYPE CHEDULE FOR MAX. 10 OASS -RETERENCE ANCHOR PACING AS SHOWN SCHEDULE FOR MAX. TYPE IN DIAGRAM ON PO. 10) SPACING AS SHOWN REFERENCE ANCHOR 3 CONNECTION TYPE IN OIAGRAt4 ON PG. 10) SCHFSPAC�NG.EAt°P FASTENER V ,, REFERENCE ANCHOR EXISTING CONCRETE. 7LOCATION, FRONT AND w o ��6°R SCHEDULE FOR MAX. $LOCK OR WOOD FRAMING BACK ANCHORS NOT REO'D _ 4 OR IO SPACING. ALT. FASTENER WITH THIS LOCATION / LOCATION. FRONT AND Cl CONNECTION TYPE / I/4-MAX. FRO" BACK ANCHORS NOT REO'O O INSIDE MOUNT SECTION, REFERENCE ANCHOR - 2w WITH THIS LOCATION SCHED PIN GUIDE TO ULE FOR MA r SCALE , 3"o T- 0" SPACIN BUSHING WASHER (1 INSIDE MOUNT SECTION ITYP.I �J SCALE! 3"= T- 0" / T YP. $0T70 EXISTING CONCRETE, OLOCK OR WOOD FRAMING EMBED. --Cl CONNECTION TYPE REFERENCE ANCHOR SCHEDULE FOR MAX. SPACING AS SPOW14 IN DIAGRAM ON PG. 91 1 -T-nn'• .,.-. GLASS FOR OR DOOR — IbL I r vi #12 x 1J2" SMS @ 12" wLL F, V m O.C. OR 3/16"o ALUM NLL7�cr POP RIVETS F196" O.C. I- V. w J15 To ) N ° OR 1/4-0 ALUM. POP SWA =�Z4xiW RIVETS 012"D.C. TO 2 CONNECTION TYPE REFERENCE ANCHOR SCHEDULE. FOR MAX EXISTING CONCRE T E, SPACING BLOCK OR WOOD FRAMING EMBED. @ BUILD OUT MOUNT SECTION EXISTING CONCRETE, SCALE BLOCK OR WOOD PRAMING OR DO OR--=11 k fOR m SEE i 1X2°ZID ¢a Q ANO Q8 1/4_20 S.S. MACHINE °I yqL ¢ o F¢- L ASSEMBLY 1/4`f1A%. FRCM PIN _ SCREW & HVT (A SFPAPAllON u yl 1/2- GUtOC TO 6G3F'IIMS; 12"O.C. TYp. WASHER (T YP) 1/4" MAX. FROM PIN � �+ - —"—' Q GUIDE TO $VS111NG w 4 CONNECTION TYPE K P ' 6 WASHER iTYP.I E GE REFERENCE ANCHOR ¢ E + '^ EXISTING CONCRETE, DIST. SCHEDULE FOR MAX. N © OR BLOCK OR WOOD FRAMING BLOCK EXISTING CONCRETE, OR WOOD FRAMING SPACING AS SHOWN '4 CONNECTIOH TYPE IN OIAGRAM ON PG. 10) REFERENCE ANCHOR 3" x 3" 1/4" C01,44 T. 3 CONNECTION .TYPE H12 x 1/2" $MS @ 12" SCHEDULE FOR MAX. S. 6063-T6 ALUM. AGLE REFERENCE ANCHOR O.C. OR 3/16"o ALUM. SPACING, ALT. FASTENER (MAY BE REVERSED SCHEDULE FOR MAX. POP RIVETS 1E, 6" O.C. / LOCATION. FRONT AND AS SHOWN DASHED)---- "-•-- Op WALL MOUNT SECTION SPACING OR 1/4"m ALUM. POP RIVETS C® 12" O.C. BACK ANCHORS NOT REO'0 - WITH THIS LOCATION U CEILING / INSIDE MOUNT SECTION SCALE, 3"= V- 0" SCALE 13'- 1•- 0" >R 2Q 1/4-20 MACHINE BOLT W/NUT Em 12" aC. OR 0I4 SHS @ 6" O.C. ITYP. TOP !< BOTTOM) Wt L np<< K W en r^ v,'dP 13 � �wO d15„x N~ONJ y1!y, _ oaI- Ww 1/4" MAX, fROM PIN ��� 1, ' GUIDE TO BUSHING �'� ITYP WASHER .) aHER N TYPE Qa NCHOR R MAX. EXISTING CONCRETE, BLOCK OR WOOD FRAMING F' WALL BUILD CUT SECTION SCALE - 3". V- 0" x F I c>C wq��o w �1 (n z �33r6• O 3a3Y U CQ rY 08-225 w 7 d I FCR ASj•IL VMd 7m� a GLASS gm 1 � •�"--" - Y J V. EXIS TIN STRUCT OR DOOR SEETAM 2 13do a tOR wt. Ou mF N 70OIIUI 70 LASS I/4"O ALL POINTS j<Z 11 d 61 SOLID SET ANCHORS S O X N N 411T" p718" MIN. CONCRETE OR s 7: ¢_¢ pz' u ^- BLOCK H. Prw o w V N I ED. DIST. - 1/ 4" MAX. FROM PIN GUIDE TO BUSHING WASHER ITYPJ GLASS TWO 1/4'•0 WOOD OR DOOR LAG SCREWS (d 2.4" V,C. MAX. WITH 2" THREADED PENETRATION MIN. 3"IN. 3, T" INTO CENTER OF STUDS E TRUSSES EMB. -T' 14 SMS IA MIOSPAN BETWEEN STUDS FOR TRACK TO 1" x 4- PLYWOOD b TUBE CONNECTION STUCCO FINISH 1- THIS DETAIL MAY 6063, T. ALVM, TUBE 1/4-0 ALL ALSO BE USED POINTS SOLID THIS DETAIL TO BE USED WHEN STUD SPACING SET ANCHORS AT TOP EXCEE05 THE MAX. ALLOWABLE ANCHOR SPACING. WITH 7/B" MIN. - -' EMBEDMENT IN C WALL MOUNT SECTION CONCRETE ORBLOCK SCALE : 3 V- 0' EXISTING STRUCTURE FOR ASIU Nnd 2m 1 m SEE IARF / h iCR BasOR —GLASS DOOR SEE ARADO 6LASSS E➢W T N ^ X Y <od £ in 14 76 1/4" MAX. FROM PIN GUIDE TO BUSHING WASHER (TYP.) 1 TILE ITYP I M11FINISH MATERIAL 3/4" PLYWOoo 114"0 A325 GRADE THRV DOLT @ 8" O.C. r OR 5/16"0 A32S GRADE TMRU DOLT (d 12" O.C. GALV. OR S.S. 1/4"0 ELCO ULTRACON TO CONCRETE/CMU +, 6" O.C. W/1-1/{-MIN. EMI). OR 1/4"0 LAG SCREW 0 9" D.C. W/1-7/8" ' MIN. EMB. IN WOOD SG.0.42. TO 0.55. EXISTIIGCONCRETE, 4, HOLLOW BLOCK OR WOOD fRAMING. SEE x _ _ _ 2" x 5" x 1/B" CON7. ANCHOR SCHED. BASED - ALUM, ANGLE (6063-T61 ON TYPE Of STRUCTURE PASS TFIRU DETAIL H (MAX. DESIGN LOAD 2 12 P.S.F.! SCALE . 3-. V- D" T. LEG DIRECTION SEE SCAM SCHEO. b NOTE J7. THIS PAGE FOR 1/4-20 MACHINE. BOLT W/NUT A5 GL¢ SIZE b ANCHORS (^ 12" D.0 OR li 1L x 3/4" RE D r SMS 6" O.C. ACCESS I A Ti o 1416 0� 4 M-Aloiz— i 13 u "4 > w �. 'aBIETRF0.2 H�_4L dz T-'T TABLE 2FOR LV. � AtAliol 0 CLAVT — uwl viwrz SEE BEAM U BOLTS I RR I' �.E FOR I Lo f' 2 1� =-SEE BEAN SCNEO. b �1/F{-20 1" NOiE J7 THIS PAGE FUR' NIFIITT'' ANGLE 512E a ANCHORS OR MACHINE BOLT W/ (A 12" O.0 1414. x 3/4" SMS 6" O.C. ACO'D (I1 ALT, LEG DIRECTION AC ESS MOLE EMBED, MAX. CIESIGN L)AD :: 72 PSF BEAM SPAN SECTION SCALE : 9". V- 0" EXISTING WOOD TRUSS OR RAFTER CM 24" MAX, O.C. EXIS71NG FINISH 1- x.4" x I/8" 6063-76 T ALUM. TUOE W/ THREE 1/4"0 WOOD LAG SCREWS WITH 2-3/4" MINIMUM THREADED P EN¢TR. "1•' IN Wt= ob I EACH RAFTER Or TRUSS 24" O.C. MAX. WHERE TUBE EXTENDS B£YONDI LAST TRUSS MORE TMAty V. EXPEND TUBE TO NEXT TRUSS. \ -20 S.S.MA,1INE SCREW M L.-D.C. IN BETWEEN TRUSSES 'ITH 1/2"0 ACCESS HOLE ON ACKSIOE OF TUBE OR 014 SMS 2A•' 0, . MAX. IN BETWEEN (MAX. DESIGN LOAD a 72 P pie�$9���� KOK= Km WIN s�iianrts�s�E�sal>n��a� l7aii[F7d9i�E7i7dt�iF>a, �Lrta�Ttir$Dsaaa�l�7a3s�asaJ Xc USE 2X3XI/4 OR 2XSX1/C 'ANGLES FOR 2XS & 2XO BEAUS USE 2%.SKI/A ANTA F.S FOR 2X8 .4 2X10 REAMS N W BEAM SCHEOUI NOT S• 11. USE BEAM SCHEDULE FOR DETAIL J . J2. TUP b BOTTOM BEAMS MAY BE USED TOGETHER OR IN COMBINATION 1JITH OTHER CONNETION DETAILS. WHERE USED TOGETHER, BEAN hUSTCBE LIMITED TO TOP BEAM SPANS. J3 LAP BEAMS ARE NOT ALLOWED. J4 ALL BEAMS b ANGLES TO BE 6063-T6 ALLOY. U3 o� K u 6 O w D T N 1 g u ALUM. ANGLE W/ THREE' ,- \ 1/4"15 WOOD LAG SCREWS WITH 2-3/4•' MINIMUM THREADED illi yr` w PEHETR.'T' IN WOOD (& T 10 'f EACH RAFTER OF TRUSS. a j a m 2L' O.C. MAX. WHERE S A r ANGLE EXTENDS BEYONO fs y LAST TRUSS MORE THAN 4 0". EXTEND ANGLE TO NEXT TRUSS- 1 1• 1P/c C) TRUSS MOUNT SECTION ' /.7 SCALE: 3". V- 0" mbllmm OR L us ORECESS Val DE SVL'F A -a T•- 0• 1. BU f T YP. 80 T TOM v—APPROVED MOUNTING PIECE MB CONDITION, MIN. OF TWO PER APPROVED FASTENER AND Two FASTEINERS PIN ER CU�OF PIECE OTYP, SECTION FOR SHUTTERS P1 SCALE: 3 - V-o' GLASS OR DOOR FOR d4P1_� *MJ 7 s SEE ABLE !fcfl I _ L• • _ f JAM 2 W SC FOR vN. SEPARATIss ON F TO aAH x f , fi ZOp=O i_. ...:`Mo IN. C•' a J z EAs�' V �t CTION TYPE = m8 a (RADIUS HEADER MpUNTED 01 $- �I CE ANCHOR Qy PARTIAL ELEVATION �v�� FSPACA- •: , xso•• SG.L":3• r- 1•-0- U=�> Ai w W a� of ,• N V1 r I EXISTING STRUCTURE rl zr Op WALL MO NT SILL DETAIL EXISTING FwISN W r MATERIAL GUIDE MAX. FROM PIN SCALE , 3". f'. 0" L GUIDE O 6U5 IN �5 R6 CUi IN C" INTERVALS;_(yf•r: ;N , .•?',y j ` WASHER ITYP.) TO FOPtU E (OSREE DETAILADDITIONAL INFO). TYPTOP& BOTTOM. FASTENER iN EACH G" CUT z Y e m a h d SEE ANCHOR SCHEDULE BASED ox F ON C4 CONdNECTION TYPE TO VERIFY ANCHOR SPACING 4 3 S �• IS ACCEPTABLE t3 Is -w'�F� oLL0 i/! 1, f•R Yv vvv � TTT"' �Iq �. •ter � .. o �~ C7 �b�g� � �� & §•n4ba� � � i+!o C e vbvvvv g U ,�a 1T II R T— 1 L'• MLY cnn,n o�, r_nn� •K f�V }� 1"sf"nl/R" & 1"x2"Af/S" MATCH6 ALUM. ANDGLE CUT TO UFCU' SHUitfR EXEIRUSIUNb? FRO T ANO BACK. WNERF FROfvT OF EXTRUSION IS CONTINUOUS, REIHFCRCEMEN7. IS NO'T REDWRED. I O2 Ma APPgOVEO MOUNTING CONDITION, MIN. OF TWO PER PIECE o SPACINGE 'ITH AT MIINIMUM OF TWO PASTEN �RS PER CUT PIECE OTYP. ALTERNATE SECTION FOR SHUTTERS P2 SCALE: 3' a I'_O (t9) CUT AT INTERVALS T EXISTING FIIJISH FORM CURVE ISEE DETAIL PP ) MATERIAL 01 CON1I10TI TYPE R[FERENCE ANCHOR SCHEDULE FOR MAX. SPACING IF ASTENER EACH a` PIECE pOCURVED TRACK SECTION DETAIL SCALE : 3"v 1'E 0" 1• 1 1' 1 unuuuuuuu©©OQiO©© ®mapm �\111111111\il4ulNilu{IL' �m mannmmanama mmOna �mmannmma©amna%/ mmnmmmmna�munen mm inumummoma%'//.�/�mma0mm00© man a VAN1 maaaam a®0 a©aa go �� el ® g® 7,1�1UtUuullll\hUug1> „ ..;.. �mM mnan BOOM %aammammmm� a©©a �mmnnnm©%gaaa/r©©mmanmm�a ma an BOB %a©mannum a ®aaa ' - [ %i0,MVS%%%%% Alvoli %%%mmmmm1mam NNIN%'// aaffiroffi/.%QlttlmommmaQl�mmaam maaam' Vim'//."%'//.�M'//:Nf�/ OW1 00010mmammmaaammapaMIN, ■ 1-114* EDGE DISTANCE aumWe"14.1i YL:1LIL MMEIM ML`7E1000M { ,tI mmmnammm nommgnnmmmmm m mmmmnam mmmngamma Dun ©oommmmmmm ®®®®mango mmmangmmannuardiffi mmnmm® m ' E!mOn �g%VIYAMOMMMUM%%%©mngau an non a � r1.3.103MEMm[1m©m®®mm MQim®®mmQ M ommmammm Damm®m® ®' mommmumm iinmmmmmmmaQ MU nmm®mm�m�mmmmagmm ffn mnngamannammmmm�ngmm®nnnm Qlmaaammuanmmuanumnaam naammaaam DISTANCE L71W®L�7�m1Jt �FJmML:7!lEl!IlF�JJA�l!l�����L1�L•f!L®`E7� 'WlLm:7lRm� �U:a,54\;5us:{k♦ �®®m����n®��f�i�YW��ffi�fYY® /mEll ®mmmmmmmammm pnnmmommmmammmn�ga r „ III mmmaammna am�®aammnm®manna®nnaa mmaaanmaalnma©aamananman© aaaL7 �mmmmmmmmmmmmam mmmmmmmmmm�°�moomm � 1Nlll1 111W f In Nil L- IBemom©© a mono®ma m� �� �m®®m Ian�noan°�%a®�©��i�Imm°1 a�®pm am TOP FLANGE nNC,,S, SEE ISP4GNG J SEG noH xl_�-_ 0 To 0 0 0 'I • YP.I E I x S Ip� IN�SySIDE 3 ORU HEADER I SILL DOT. PLAN SECTION XI F SPACING SIDE CLOSEST TO OPENING NOTE, "S" INDICATES ANCIIDR SCM(BUILF. EDACING SPACING DIAGRAM FOR 01 CONNECTION TYPE: C1 CONNECTION TYPE USING PIECE 3 OR 4 "/COHBINATON CONOINATHIN COMBINATION Ilr SifYp. 2.s ITYPI vSITYPI I7 I NOTE, -S- INDICATES ANCHOR.S[HEDULE SPACING. SPACING DIAGRAM FOR C3 h C4 CONNECTION TYPE: C3 CONNECTION TYPE USING PIECE WITH OUTSIDE ANCHORSo ONLY [c CONNFCTION TYPE USING PIECE 0 OR @ WITH DUTSIOE ANCHORS ONLY 1. VANS AND LOADS SNOW: HERE AAE FOR OEIE.RWNRIG ANCHOR SPAQNG ONLY. ALLOWABLE STORM SHUTTER SPANS FOR SPECIFIC LOADS MUST OE WITED TO THOSE 910M EI TAM I k 3 (P9 I). 2.DHER ANCHOR SCHEDULE BASED ON 711E M11'I0 SIMCI'JRE V41MA_ ANCHOR TYPE ANO fOOE dSTaHCE. SELECT OESIGH LOAD CtEATER TAH oft CWAL To NEG.AnVE QESON LOAD Ott SHUTTER AND SELECT SPAN GREATER THOZi DR EWAL 10 5HUITER SPAN, 3. SSEEEEEMOURPNO SECTION OMILS FCR ILIEMHCATION OF CmNEC7m TYF <.(XIST.NG STRUCTURE MAY BE CONCRETE. ASTIA C-90 HOLLOW CONCRETE BLOCK OR WOOD FRAMING. FLEFERCNCE ANHHOR too= FOR PROPER MCNOR 1WE.BASEo dI IYPE a EOSDUO STWJOTUPE MO APPROMEAIT` CONVI" TV. SEE CONPNECTIOI LIETALS FOR IDENTIFICATION OF CONNECTION ITPE. &THE CONTRACT(q 6 RCSPO7518LE 10 ENSJRE THE MDIOFTS ARE INSTALLED IN ACOCtOIRCE MNH MAHUFACiVRERS' RECOI.IMENDATIOn EUDEGUENT LEIHGMS SLAIL DE AS NOTED AND DO NOT INCLUDE STUCCO OR OTHER EW I ES. 6.KNERE EAISTNO STRUCTURE IS WOCO FRAWNQ WOOD FRALIDNG CONDITIONS VARY. NEED %UWY THAT FASTENERS ARE INTO ADEQUATE W1K0 FRASANG MEMDERS, NOT PLYWOOD, FASTEIRNO TO PLYINOD IS ACCEPTABLE &V FOR SIDE 0.0S>;RE AECCS. 7.WNERE LAG SCREWS FASTEN TO NARP.OW FACE OF STND FRAWNB FASTENER SHAU, DE LOCAIQD IN CENTER OF NoUtNAL 2' x i" ((N'HJ WOOD STUD. 3/4 MOE OIS1AIt^,.E IS ACCEPTABLE FOR WOOD, FRALIINC LAG SCREWS SHALL HAVE PWLUPS PM HEAD OR HEX HEAD. &MAOURE SCREWS SOU. HAVE t/ WU1 OF 1/2- ENGAGEUDN OF T I FADS IN BASE ANCHOR No )JAY TIME EITHER A PAN HEAD. TRUSS IIEAD, OR WAr[R DEAD (SIDEWALK COLT); U.O.H. ® DESIGNATES 9101OR CONDITIONS WIECH ARE NOT ACCEPIABU USES DESICATES ANCIORS u1HOH ARE RE40YADLE DY.RDAOLLNC MACHINE SCREW. OUT OR WASHER TANDWT. 9. FOR 5/16.6 CLOD CRETE FLEX, CONCRETE f.-3.35 KS, FOR ELCO OLTRACdf. CONCRETE T4-3.5 KSI, FCN NW FAFCON, CONCRETE Tc-3,2 KS, Dn1ERWISE WIN, I'd <. 3 KS. --4 ANCHOR SCHEDULE FOR CONCRETE BLOCK ' •. I- EDGE 'ISTANCE MIN, 2-112" EDGE DISTANCE ® CONNECTiou TYPE JSEE NOTE 3) , •iiP1L3l��S13uJ13� i Il r � r '. 111HN11111111111,t. , , r _ 71�U1,IH1H111H1„H,RH7 60�..6� �m ©®000y�o©© mm®°m�©°o©Q�®a an © ommmmmW, vo m mmIOWX iimm noun �,Bun ©! io�m �m�mo° . , �mm9ommo mo° , m momm ©000�ino •, moor.©©© r °� mm��°p oo�.© om i © mom on m ymo° �omVol4o�im© ,,, ' , • .!/ ,dim/.�%ram.,i'//.!i�i.�f� ti�W RON nuno©ro%MN.1-9/16-E STANCE I K • I w • I I, i F a®m�iI mm mY 7 Aillk1111bt1h11N1 11 �i©mm FIRM �mm a©©mm©omm an Mii fig..®e��������i��®®�� 8H2N(14 NOR'G -SEE PACE 10 _•-- _i �m0 mmmm0°mm® ©© m°°mD OVA //•.%0Qt%/�%0�%m'//. �mmr, ar°mr�m As�,ri 0 IN til4im�©00®0�©®©© �©©©©om©mom©® •. . , ANCHOR SCHEDULE FOR WOOD SG-DAIMIN. MAXIMUM FASTENER SPACING (INCHES) REQUIRED NRVARIOUS DESIGN LOADSAND SPANS Lm M(N.3J4'EDGE DISTANCE NCHOR TYPE B MINIMUM EQUIREMENTS (VQ P.S.F. MAX. (SEE SPATS UP TO G-W SEE NOTE 1) SPANS UP 70 6V SEE NOTE 1) SPANSU PTO Iy0' (SEE NOTE 1) COhNKn01TYPE cO6NCClollTYPE 05NNFC1101TYPE NOTE (SEENOTE3) (SEENOTE3) (SEE NOTE 3) 1) cl Q C3 C9 LY cl Cl C3 c4 cS cl C2 I C3 I C4 I CS 49.0 16 16 I 9 11 13 15 16 6 1 B 1 9 16 16I 4 WE 62,0 f6 16 7 9 10 16 S6 5 6 ) IS 9 3 1 . 1YITH 1114' 71b1EA0 P;t&IRAnM PAAAILELORPERP,TO WO, N _ S. OR GN.Y_FRILM 71.0 - Sb I6 6 7 9 16 16 4 S 6 13 6 3 9 If0.0 l6 16 q 6 fi 12 6 3 4 IO a 3 N 94 10 4 3 3 10 1 3 1_ 10 4 3 r 3 j��,��1,jI1TI1I11111tt11U= 48.0 16 16 8 10 13 15 15 6 7 _ 9 13 13 3 4.' fi _ l 4*1 ilq))S15 :ss�3RR re tiflOCb SCREWMIH I.3,f1' W+N. THREAD PENEMTTON �•0 16 16 6 8 10 15 IS 4 5 ) 10 6 •1 . ; 72.D --- 16 116 5 7 - 9 11 ll 3 1 G 9 i j 13 f+ARY1ELCRPERP. TO I WOODGRAUI .OkO FINISHED n0.0 li 11 3 4 S 8 6 I q 7 3 lO6A 7 S — .3 -- 7 3 3 — 7 3 1 U6-225 1 .127 {{ , .121. R(IUNDN7xC0�Y Y �`. (EXTERIOR) (INTERIOR) ; + 1 , 287S DIA ). .1837 .16C ? r -DUAILM I :1 .145 41 sw ;T N•VIruFsuE EVI WINDOW LIGH B ROUND WINDOW 13a s•=1•-0 .I61' rye......_ 1 -c (EXT.) (INT.) %'' r- •: �j i• uArcRfE E1DDEAND JT EIhYI 'DOSS HOLY, TOYni'GAAE tI xT r (Do 1 42 RECTANGULAR WINDOW FRAME 6 DLOWUP DETAIL --�.e7s DUl1 EMU �q{6p.0�00'F:AF NE `�r`'ii 155E n (�pp gp5gp �L k-+•:; i RREE[['EE % lD,m p�R ` __..ACfrptk7AAAYlR 75 fER �YJ FSr-T-„ / �_.- tYItf00WlSSE,MIRY �r 'ERY �R0. &IME !: IFIWFRYU O{II CRf f W ..,. _ _ i j W ZLDGIZ OF�..... htiI --;NJ >LA �hil aUUUU1�� owt3 �, Ll �- UUDUUUIU V>z' I 56_ i. t6000-MOLE & N •n °" �� weLi' 1YIAOOWASSEtiBLYJ 31 2,7-j �" '.;: Ja R57�2D��V 0.SSE.'1EYY ' x O�t� II I ` �"• T, b � I I O 4 tr YAA1E5 tt0 DHl i pp a o ACCORDION ELEVATION WITH WINDOWS I I I ScuF: V2 =1.0 O •> I I' �f•, f I�IM 1. THEsel" lIATIONDOMMUSU-MBENTASIR,ITERSY57EN 1V1111Y711 NULYZEO WII11 nlENNY75TOH5 SET �C .bl Ik fORRIE]SSVASYR OFAP.OR2DAMUILDPIG CtlR P0.0DDLTM"FR(N/LiF;[S FRWlti71S9RiRBtE FOR Ut5TP1UTIDt11H o III{ f I �DIWITHRECTANGULARWIIIDOW NfASCfIEUIQIYElOC1TYIRFWfANE20NE(141II8NgYMaIYElggi/hURRW2EIOhE(NQVIMIn. 13bEGE=f� 2. THISSYSIENlWBEDIIESTEDAYDEVALLIATEDPFAISIHCOIilWirHLJ.Txt551SIEN REW[1H1HEEID?1DAMUILLIIN0000E(EBCi q�p�{R°FFHES,llRI;DJ FXE x131VEWCHY ARIWn2aEff(iEiFE756MS5!EEEErE'D'AVD ` f i xClUDE5141r26204t 4 AS DEFINED INASTM E1995-0s. I I I 3. TE5t112G V,ASCD!iDiAiED IN A(CORO4N(E IYfiN TA520(,2021103 AVDASTM EIBE6052E1996051E331Pt. �r. 1?�f�-' 1, T105 SI'S'iEM w EE91 TESTED ANDEYAIMIDAW 15111 WiFLL6)a WHTHTHE I1rtERMj!WIAE 801lon EODE(in AND THE P4iFA,1A210H4l RESIDENCE CODE(UtC} 3.. . •. \ :•^ 'cif":i S. fpUKREASE i4All0Y2AMIE SfAfS5iP5BEEN U$ED CY 71tE Df5161 OF THESE PRODl1CIS. .•, 1- - A➢PRC o96RRR Cry g 7 TYPICAL PLAN VIEW OF ACCORDION WITH WINDOWS =1 U10612010 1:2fi:06PM• 11 x U. 1:1. w•nv.MiDinv .mn APAiO'AU, GB ACCOPD:ON SI'.lffTER 6YSTEH DRAT51HG � � �' 7. 7NERWINYlL'f(XM; COMMUEHT(41) IS MOE FFM MrC PASTICS SUJ43ET{-94JJD(iWoVS55fgV5YljMt„ CO.WOAEHi DETAiIJ. II& TFIE PMAVUM%VUl-V-YM0NhM DEtAlt 13815 MADE FROM GE31.20 LMJVMH QD25'MUIINRITr110d $ I9. FRAME /OR REC7At1GUARWINDOVr MAY (2FILO,Nfi OR TLYCAS(tONAlEWf1HAMINIHI;N71Rg11E550F 0.151'Al 70&AD: Y2RH (6)!I ST,2AES5 STEEi SCREVfS OR BOL751V1T.1 RUTS. a" f