Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSDATE: FEES DUE: RECEIPT #: Permit #: Til St. Lucie County Building & Zoning SCq��� e 2300 Virginia Avenue Ft. Pierce, FL 34982-5652 �Y M..r Tel. 772-462-1553 t tUC/�1 C ` © APPLICATION FOR ROOF PERMIT count 1. Location/Site Address: IS.lJSL�� \� 1 IID� ORCS RUCTION -a ©VI - 2. Parcel ID Number: Office Use Only Section Township Range Map Page Zonin Land Use Initials . I I 3. Description of Project or Work Activity 4. Total Roof Area (square feet): 400 5. Roof Pitch: a • S . I `*L oT D K4 6. Type of Roof: [ ] Fiberglass Shingle [ ] Concrete Roof Tile [ ] Wood Shake / Shingle [ ] Tar & Gravel [ V Modified Bitumen [ ]+/ Other 1r nl /l Amid [ ] N.O.A. or Florida — Product Approval requh2qor all types of Roofing Material (2 Sets) I q 0 [ ] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product Approval attached �* Roof Mitigation per F.S. 553.844 will be required. 7. Owner Information II 8. Contractor Information2 Name. iR• E N FL Reg/Cert #: CG 61 J 25 Q D9 Address: 16, County Cert #: 0 ll City: , 1 • CIE State: Business Name: 06 6 MC - Zip: Q Phone: 9. Value of Construction: $ `Z,� ©0 Fees Due: Receipt #: Note Dry -in and Final Inspection Required Additional inspection may be required per Product Approval CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all of the informagpn Rained in this application is correct and that all work will be done in compliance with all ap ,lic Maws regulating construction and zoning. �yIE -WM t PRINT QUALIFIERS/OWNERS NAME SIGNATURE OF QUALIFIER/OWNER STATE OF FLORIDA, COUNTY OF :� I j(1L ACKNOWLEDGED BEFORE ME THIS I LD DAY OF, 201_, B rlp, 1 Ae WHO S PE!MY Y KIJWN V/TO ME OR HAS PRODUCED AS IDENTIFICATION NOTARY PUBLIC -STATE OF FLORIDA . (�isen ,'�� SIGNNAME N SIGNATURE OF NOTARY TYPE OR PRINT OF OTAR: Karen S =Commission # a1000358 %•° Expires: JUNE 12, 2014 COMMISSION NUMBER )bIOn3�1 BONDED THFtUATLANTIC BONDING CO.,INC. NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OI: ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. JOSEPH E. SMITII�,— a°RK OF THE CIRCUIT COURT AFTER RECORDING RETURN TO: SAINT LUCIE COUNTY J. A. TAYLOR ROOFING, INC. FILE # 3597522 06;0120-11 at 10-02 ,40 302 MELTON DRNE OR SOCK 3298 FACE 36C - 365 Doc Tape: NC FORT PIERCE, FL 34982 RECORDING: $10.00 PERMIT NUMBER: NOTICE OF COMMENCEMENT The undersigned hereby given notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida statutes the following information is provided in the Notice of commencement. 1. DESCRIPTION OF PROPERTY (Legal ascription and street address) TAX FOLIO NUMBER: I "��d' 0��0' SUBDIVISION �T�BLOCK TRACT LOT (�_BLDG UNIT d� 3. OWNER INFORMATION: a. Name 1 Poo SF Trjfl (:y'�i'Sf LLl(r/� py. q&&j b. Address - p U L Z H IEDA 13 NJ N c. interest in property_ A I�,IYIe r d. Name and address of fee simp a titleholder (if other than owner) 4. CONTRACTOR'S NAME, ADDRESS AND PHONE NUMBER: J. A. TAYLOR ROOFING, INC. 5. SURETY'S NAME, ADDRESS AND PHONE NUMBER AND BOND AMOUNT: 6. LENDER'S NAME, ADDRESS AND PHONE NUMBER: 7. Persons within the State of Florida designated by Owner upoh whom notices or other documents may be served as provided by Section.713.13 (1)(a) 7., Florida Statutes - NAME, ADDRESS AND PHONE NUMBER: 0 1 f\ 8. In addition to himself or herself, Owner des gnates the following to receive a copy of the Lienoes Notice as provided in Section 713.13 (1)(b), Florida Statutes: NAME, ADDRESS AND PHONE NUMBER: A I P\ 9. Expiration date of notice of commenceme t (the expiration date is 1 year from the date of recording unless a different date is specified) , 20 WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. L Gt Lim Signature of Owner or Print Name and Provide Signatory's Title/Office Owner's Authorized Officer/Director/Partner/Manager State of Flo ida County of The foregoing instrument was acknowledged before me this 10 _day of ryl `� , 2041 1 By U1 ill �,YV1 W �N , as (Printed name of person signing above) (Type of authority... e.g. Owner, officer, trustee, attorney in fact) For (Name of party on behalf of whom instrument was executed) Perso ally own or produced the following type of ID: - 1 > NOTARY PUBLIC -STATE OF FLORIDA Karen S. Nielsen (Printed Name of Notary Public) (Signature of No ary Public) j _CommissjoA- PD1000358 ........ Expires: JUNE 12, 2014 Under penalties of perjury, I declare that 1 have read the foregoing and that the facts V"%we and belief (section 92.525, Florida Statutes). Signature(s) of Owner(s) or Owner(s)' Authorized Officer/Director/Partner/Manager who signed above: taiynawic) trnniea Name/ Rev. 08r3=007(Recorfing) 06/08/2011 12:22 7724688397 JATAYLOR PAGE 01/01 Public Works Department Code Compliance Division 2300'Virginia Avenue FL Pierce, FL 34982-5652 INSPECTION AFFIDAVIT RE: Permit 4 _U of - mll ,licensed as a Ontr; ctor ngineer/Architect/ (Please print name and circle'license typo) 'FS 468 Building Inspector* * General, Building, Residential, or Roofing Contractor or any individual certified under 468 F.S. to make such an inspection. All affidavits must include photographs of each plane of the roof with the permit # or address # clearly shown marked on the deck for each inspection. 4n or about z did personally inspect the roo Based upon that examination l have determined the installation, was done according to the Hurricane Mitigation ctroiit Manual (Based on. 553.844 F.S.) Signature & Seal License # STATE OF FL R1DA COUNTY OF LCIE , Sworn to and subscribed before me this ' _,day of �tj .2041 by . Who is personally known � ��®rho has produced as identification. NOTARY PUBLIC -STATE OF FLORMA Karen S. Nielse�a Notary Public, State of Florida ~-Curamission fDD1000358 ,.= Expires; Jun. 12, 2014 HONA}eD TFiRII ATLANTIC 139tJbIN6 C4., INC. Signature RECEIVED Commission No.`ja�l�' _ cm_ 9/27/0y7% / rj / _ 1 /, Jda�6 8 2011 Public, St. Lucie ,,:; 06/08/2011 14:52 7724688397 JATAYLOR PAGE 01/01 Public Works Department Code Compliance Division 2300 'Virginia .Avenue Ft. Fierce, FL 34982-5652 INSPECTION AFFIDAVITJI ID RE: Permit # ,licensed as a Colttzactor yngineex/Architect/ (Please print name and circle license type) `FS 468 Building Inspector* e Gencral, Building, Residential, or Roofing Contractor or any individual certified under 468 F.S. to make such an inspection. All affidavits must include photographs of each plane of the roof with the permit # or address # clearly shown marked on the deck for eacb inspection. On or about I did personally inspect the roe (Date &time) d naidin o ecoradai water harrier ' ork at c rcle one _ (Job Sitc Address) Based upon that examination I have determined the installation was done according to the Hurricane, Mitigation etrofit Manual (Based on 553.844 F.S.) f Signature & Seal License ## STATE OF )~la R1DA COUNTY aF U Sworn to and subscribed before the this day of _ . 2041 /orby �' J _. Who is personally known who has produced as identification. NOTARY pui3j iCGSTATF OF FLORMA s„ 1{;tren S. Nielsen Rxpixt s: Jt JNE Notary Public, State of Florid2, 2U14 a :Copitrission #AD10003513 �,,,,� DONnBbTxaunTJ.NancnoNl�TNaca,tNC �Z/41 0 �A Signature t Commission No.--na f . cml9/27107 , r 4 SECTION 1525 HIGH -VELOCITY HURRICANE ZONES UNIFORM PERMIT APPLICATION Florida Building Code Edition 2007 High -Velocity Hurricane Zone Uniform Permit Application Form. INSTRUCTION PAGE FILIr.0-copy" COMPLETE THE NECESSARY SECTIONS OF. ,:Per) THE UNIFORM ROOFING PERMIT 001 b. APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Attachments Required Permit Application Form List Below See Low Slope Application ✓ A,B,C 1,2,3,4,5,6;7 Prescriptive BUR-RAS 150 A,B,C 4,5,6,7 Asphaltic Shingles A;B;D 1,2,4,5,6,7 Concrete or Clay Tile A,B;D,E 112,3,4,5,6;7 ✓A B D 1,2,3,4,5,6,7 HARVEY E. KOEHNEN Metal Roofs Professional Engineec�$2831 1 2 4 5 6 7 7205 Elyse Circle Wood Shingles and Shakes A,B,D ,• ' ' ' Port St Lucie, FL 34952-3212 (77,2) 489-3035 ,fax Other As Applicable 1,2,3,g,5,6,7 ,.�_{ % ATTACHMENTS REQUIRED: T2-From Directcfy Listing page ProductApproval:ront Page pecific System'D"escripiibil Specific System Limitations General Limitations Applicable Detail Drawings -3. Design Calculations per Chapter 16, or If Applicable, RAS 127 or RAS' 128 4, ether Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing- Only) - 7. Any Required�Roofesting/Calculation Documentation 2007 FLORIDA BUILDING CODE CoMMEI&aa� ' 1 r-ra ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida BUildi'ng Code Edition 2007 Uniform Permit Application Form. I Segti Master Permit No. Process No. Contractor's Name -� + d: - 1 4,x LbCz_z Job Address ADO 5.1=, [ E LES7'1A. , r-T. ROOF CATEQORY 1 Low Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tile Asphaltic ' 14 Metal Panel/Shingles ❑ Wood Shin gleslShakes. Shingles 0 -Prescriptive BUR-RAS 150 ROOFTYPE ❑ New Roof 4 Reroofing ❑• Recovering ❑ Repair ❑ Maintenance If ROOF SYSTEM INFORMATION Low Slope Roof Area 8 (� i ( F) Steep Slo ed Roof Area (SF) Total S �t oD - 2.4�a - -Section.B (�oQ� - I Sketch Roof Plan_ Illustrate ail levels and sections, roof:drains,.sc ippers,•overflow scuppers nd ove OWVEY,E. KQEHNEN include dimensions of sections and levels, clearly idenfify dimensions of elevated pressurez nes aroi��nS'aod�n9Vfgineer 32831 parapets. 71rOS1 a circle Port St. Lucie, FL 34952-3212 ( s (772) 489-3035 fax III I E_ 11 INO' •E: * em e e isti g r of g to pl ood ep ' ce r e p w1 shank nails . (0.113" diant. full round head 2" gong) Spaced 6" o.c..at ends & fie¢d to trusses 2007 FLORIDA BUILDING CODE COMMENTARY , ROOF ASSEMBLIES AND ROOFTOP STRUCT( f� Florida Building Code Edition 2007 High -Velocity Hurricane Zone Uniform Permit Application Form. . Section C (Low Slope Application) Surfacing: Fill in specific roof assembly components and identify manufacturer Fastener Spacing for Anchor/Base Sheet Attachment, . (If a component is not used, identify as 'NA") Field: " oc @ Lap, # Rows Z @ (Z " oc System Manufacturer: S. M APP Mo D ear TSf f- Tlr evt� a Perimeter: 'oc, @ Lap, # Rows .Z @ ? " oc Product Approval No.: 0&-04. 17r09 t 3 b B Corner: '10 " oc @ Lap, # Rows 1' @ " oc Design Wind Pressures, From RAS 128 or Calculations: _ Number of Fasteners Per Insiilatiop Board: Pmax1 • - 4' Pmax2: 5 l' b Pmax3: " 7('O'g Field Perimeter. Corner Max. Design Pressure, from the specific Product Approval system: 52.5 Illustrate Components Noted and Details as Applicable: Deck: ; Woodblocking, Gutter, Edge Termination, Stripping, Flashing Type: i'�LY uJoop Continuous Cleat, Cant Strip, Base Flashing, Counter- G� Flashing, Coping, Etc. Gauge/Thickness: 1 73Z Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness„ FastEkney Slope: �� 2 TP e Fastener Spacing or Submit Anchor/Base Sheet & No. of Ply(s): P. ? 2.8 Z Qai S Anchor/Base Sheet FastenerBonding Material: APPRoa5y tQ--FIIJL' r1P.lyy -rim 4..4-PS Insulation Base Layer: -' Base Insulation Size and Thickness: Base Insulation Fastener/Bonding Material: Top Insulation Layer: Top Insulation Size and Thickness: — Top Insulation Fastener/Bonding Material: Base Sheet(s) & No, of Ply(s): Base Sheet Fastener/Bonding Material: Ply Sheet(s) & No. of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: 1'.QPeX 4 5M Top Ply Fasterer/Bonding Material: k e-PcT NU 91-G R� U Y_ HARVEY E. KOEHNEN Professional Engineer 32831 +' 7205 Elyse Circle .Port St Lucie, FL 34952-3212 (772) 489-3035 fax Parapet Mean Roof Height 15-58 2007 FLORIDA BUILDING CODE COMMENTARY ROOF A' __1BLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2007. High -Velocity Hurricane Zone Uniform Permit Application Form. Section Q (Steep Sloped Roof System) Roof.Sy§tem Manufacturer: C> tZ r-)4 F_ L 5- V Z 4- 4tk Notice of Acceptance Number: ep8 615 Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculation 27. 8 P2: 4t' P3: -71. Co* Maximum Design Pressure (From the Product Approval Specific System): HARVEY E. KOEHNE &C) 957-f LZ j4" - D. C . Professional Engineer 7206 Elyse Circle 12831 3212 Steep Sloped acyof System D-escri-potion Deck Type: Roof Slope: Type Underlayment: T Roof 121 Insulation: 7 Fire Barrier: Ridge Ventilation? Fastener Type& Spacing: -rif-4-0 C F9 F40AX . Adhesive Type: F Type Cap Sheet: Mean Roof Height: Roof Covering: 41? Type& Size Drip Edge. 2007 FLORIDA BUILDING CODE COMMENTARY 15-59 MIAMIDADE M BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) Johns Manville Corporation 71717" Street Denver, CO 80202 MIAMI-DADE COUNTY, FLORIDA METRO-DADE FLAGLER BUILDING 140 WEST FI.AGLER STREET. St)ITE 1603 MIAMI, FLORIDA 33130-1,563 (305) 375-290 t FAX (305) 375-2908 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted ltas been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade Coun 32831 Pro rQ. Division that thus product or material fails to meet the requirements of the applicable building €�d�ssional Engineer KOEHNEN EN This product is approved as described herein, and has been designed to comply with the +11 c eyse FL 34952-3212 Hurricane Zone of the Florida Building Code. (77.2) 489-3035 Fax DESCRIPTION: Johns Manville APP Modified Bitumen Roofing Systems Over Wood Decks LABELING: Each unit shall bear a permanent label with the manufacturers name or logo, city, state and `L ` following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been Y no change in the applicable building code negatively affecting the performance of this product - TER' b INATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination acid removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it sliall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No. 03-0212.01 and consists of pages 1 through 16_ The submitted documentation was reviewed by Jorge L. Acebo U NOA No.: 06-0417.09 w Expiration Date: 06/14/1.1 Approval Date: 06/22/06 \ Page 1 of 16 ROOF LNG ASSEMBLY APPROVAL Cate orv: Roofing Sub -Category: APP Modified Bitumen Deck Type: Wood Maximum Design Pressure -52.5 psf Fire Classification: See General Limitation #1 TRADE NAAms OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Product Dimensions Test Product Spec ification Description JM APP Base 150 sq. f . roll ASTM D 5147 APP modified asphalt, fiberglass reinforced, smooth surfaced base sheet. APPeX 4S 32.8' x 3.281; 90 ASTM D 6222, APP modified asphalt, polyester lb. roll type 1, grade S reinforced, smooth surfaced membrane. APPeX 4.5M 32.8' x 3.28 ; 90 ASTM D 6222, APP modified asphalt, polyester lb. roll type I grade G reinforced, mineral surfaced membrane. APPeX 4.5MFR 32.8' x 3.28 ; 90 ASTM D 6222, APP modified asphalt, polyester lb. roll type I grade G reinforced, fire -retardant, mineral surfaced membrane. APPeX 180 32.8' x 3.28; 90 ASTNT D 6222, APP modified asphalt, polyester lb_ roll type I, grade G reinforced, smooth surfaced membrane:. Bicor MFR 39-3/8" x 34' ASTM D 6223 APP modified asphalt, polyester,' glass reinforced, granule surfaced membrane. Tricor MFR 39-3/8" x 34' ASTM D 6223 APP modified asphalt: polyester / glass reinforced, granule surfaced membrane. Bicor S 39-3/8" x 34' ASTTVT D 6223 APP modified asphalt, polyester / glass reinforced, smooth surfaced membrane. Tricor S 39-3/8" x 34' ASTM D 6223 APP modified asphalt, polyester / glass reinforced, smooth surfaced membrane. / `t PermaPly 28 36' x 108; ASTM D 4601 Type II asphalt impregnated and coated 72 lb. roII glass fiber base sheet NOA No.: 06-0417.09 Expiration Date: 06/14/11 Approval mate: 06/22/06 Page 2 of 16 Membrane Type: APP Deck Type 1I: Wood, lion -Insulated ,Deck Description: 19/3," or greater plywood or wood plank System Type E: Base sheet mechanically fastened. All General and System limitations apply. Fuse Sheet: (Option #I) One ply of JM APP Base, PermaPly 28, Glasbase Plus or Ventsulation mechanically fastened to the deck with JM UltraFast, OIympic or Tru-Fast metal plates and fasteners at a 4" side lap 1.2" o.c. and two rows staggered in the center of the sheet 18" o.c. Maximum Design Pressure —45psf—See General Limitation 49.) (Option 42) Minimum two plies of RV1 Pe.rmaPly 28 or Ventsulation simultaneously fastened to the deck lapped 4" and fastened with approved roofing nails and tin caps 9" o.c. at the lap and two rows staggered in the cente of the sheet 12" o.c. ✓ ; >1 IARVEY E. KOEHNEN i Professional Engineer 32831 (Maximum Design Pressure—52.5psf—See General Limitation 47.) 7205 Elyse circle Portt st. Lucie; FL 34�952-3212 (Option #3) Minimum two plies of JM PermaPly 28 or Ventsulation (7,72) Sy'89=3036 Tax simultaneously fastened to the (leek with JM Ultrafast fasteners and Metal Plates . spaced 9" o.c. in a 4" lap and 12" o.c. in two staggered rows in the center of' the sheet. ; WaWmurn Design Pressure—52.5psf—See General Limitation #7. i V7 Ply Sheet: (Optional) One or more plies of JM APP Base, APPeX 4S or APPeX / 1'BQ:heat l welded to base sheet. ' Membrane: J One or more plies of APPeX 4S, APPeX 180, APPeX 4.5M or AP ' APPeX 4.� NIFI? heat welded. Surfacing: (Optional) install ouc of the following for all systems that do not achieve acceptable fire ratings through the use of FR membrane sheets. 1. 400 lb./sq. gravel or 300 lb./ sq. slag in a flood coat of approved mopping asphalt at a rate of 60 lb./sq. 2. Karnak 97, Karnak 97 AF, Monsey Premium Long Life Aluminum Roof Coating Asbestos Free of Monsey Prograde Aluminum, JM Topgard Type A, Topgard Type B, JM Aluminum RF CT, Grundy AL MB aluminum coating at a rate of 1-1/2 gal/sq Monsey Aquabrite, Gardner asphalt emulsion, APOC Sunbright 400 or Henry 229 Aluminum Emulsion at 21/ gal/sq or APOC 212 Aluminum Roof Coating at 3 gal/sq. 3. Grundy 20 F asphalt emulsion, Endure Asphalt Fmulsion, APOC 302 or 302 AF applied at 2%2 gal/sq with optional 60 lbs./sq. of roofing granules embedded in wet coating. Maximum Design Pressure. See Fastening Options Above NOA No.: 06-0417.09 Expiration Date: 06/14/11 Approval'Date: 06/22/06 Page 15 of 16 WOOD DECK SYSTEM LEWITATIONS: 1 A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically listened base or anchor sheet. GENERAL, LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the .l?VT range and at a rate of 2040 lbsJsq., or mechanically attached using the fastening pattcnz of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. Ali overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Fneircl ng of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs_/sq_ Note: Spot attached systems shall be limited to a maximum design pressure of -45 psE 5. Fastener spacing for insulation attachment is based on a M inimum Characteristic Force (F') value of I/ 275 lbf, as tested in compliance with Testing Application Standard TAS 105_ If the fastener value, �V' as field-tested.,are below 275 lbf. insulation attachment shall not be acceptable. 1. 6_ Fastener spacing for mechanical attachment of anchor/base slieet or membrane attachment is basedon a nvnimum fastener resistance value in conjunction with the maximum design value listed withina specific system. Should the fastener resistance be less than that required, as determined by the' Building Official, a revised fastener spacing, prepared, signed and sealed by a Flori a cg1 h EY E. KOEHNEN Engineer, Architect, or Registered Roof Consultant maybe submitted. Said revised fastmarzjfigi Engineer 32831 shall utilize the withdrawal resistance value taken from Testing Application Stands s TAS l t72dEryse circie calculations in compliance with Roofing Application Standard RAS 117. TFi�Pert St Lucie, EL 34952-3212 7. Perimeter and corner areas shall complyP p q with the enhanced uplift pressure re uir (77 ) 489-3035 fax areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and comers). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) END OF THIS ACCEPTANCE NOA No.: 06-0417.09 _ Expiration Date: 06/14/11 -4 -- Approval. Date: 06/22/06 Page 16 of 16 M I A M I•DAT BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE Drexel Metals Corporation 204 Railroad Drive Ivyland, PA 18974 MIAMI-DADE COUNTY, FLORIDA METRO-DADE FLAGLER BUILD [NG 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130-1563 (305) 375-2901 FAX (305) 375 ::908 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction material:. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). . This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: DMC 5-V 26Ga. Steel Panel over Plywood deck LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. \f INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at.the request of the Building Official. HARVEY E. K09HNEiN This NOA consists of pages 1 through 5. Professional Engineer 32831 The submitted documentation was reviewed by Alex Tigera. 7205 Elyse circle Port St. Lucie, FL 344962-3212 (772) 489-3036 fax NOA No.: 08-0507.05 _R MMEM Fgpir.2tinn. neter06/26/13 Approval Date: 06/26/08 Page 1 of 5 ROOFING SYSTEM APPROVAL: Category: Roofing Sub -Category: Metal, Panels (Non -Structural) Material: Steel Deck Type: Wood Maximum Design Pressure-121.75 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Test Product Product Dimensions Specifications Description DMC 5-V 26Ga. Length: 120" TAS 110 Corrosion resistant, galvanized steel or Steel Panel Height: 1/2" galvalume metal panel. Width: 26" (24" coverage) Thickness 26 ga EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Reyort Date Akzo Nobel Coatings, Inc. Lab Form ASTM G 153 PRI Asphalt Technologies, Inc. AKZC-001-02-01 ASTM B 117 10/08/02 AKZC-001-02-02 AKZC-001-02-03 AKZC-001-02-04 AKZC-001-02-05 Architectural Testing 58641.02-122-44 TAS 100 09/22/05 Architectural Testing 58461.01-122-44 TAS 125 09/23/05 Hurricane Test Laboratory, Inc. 0287-0512-07 TAS 125 07/23/07 PRI Asphalt Technologies, Inc. DMC-0030-02-01 TAS 100 04/02/08 NOA No.: 08-0507.05 r��nrei•Da,oL counrtY Expiration Datc: 06/26/13 Approval Date: 06/26/08 Page 2 of 5 i APPROVED ASSEMBLIES: System: DMC 5-V, 26ga. Steel Panel Deck Type: Wood, Non -insulated Deck Description: New Construction 19/32" or greater plywood or wood plank. Slope Range: 1/2": 12" or greater Maximum Uplift See Table A below ;Pressure: Deck Attachment: '4 In accordance with applicable Building Code, but in no case shall it be less than 8d annular ring shank nails spaced 6" o.c. In reroofing, where the deck is less than 19/32" thick (Minimum' /32") The above attachment method must be in addition to existing attachment. Underlayment: Minimum underlayment shall be an ASTM D 226 Type H installed with a minimum 4" side -lap and 6" end -laps. Underlayment shall be fastened with corrosion resistant tin -caps and 12 gauge 1 1/4" annular ring -shank nails, spaced 6" o.c. at all laps and two staggered rows 12" o.c. in the field of the roll or any approved underlayment having a current NOA. Z• LhgaQS 'Fire Barrier Board: Any approved fire barrier having a current NOA. For class A or B fire rating, install minimum'/4" thick Georgia Pacific "Dens Deck" (with current NOA) or minimum 4mm thick of Tritex, RockRoof (with current NOA) or 5/8" water resistant type X gypsum sheathing with treated core and facer. Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133 and with the current published installation instructions and details in DMC Association of Regional Manufacturers Installation Manual. Metal Panels and Install the "DMC 5-V 26 gauge Steel Metal Panels" including flashing Accessories: penetrations, valleys, end laps and accessories in compliance " A E. KOEHNEN of Regional Manufacturers" current, published installation insti uctippa A&631 Engineer 32831 compliance with the minimum requirements detailed in Roofin Applicaliaasi E1yscircle Standard RAS 133. POrtst. Lucie; EL 34962-3212 (7_72) 489-303a fax Panels shall be secured along the top of the V's with approved corrosion resistant #9 hex head self drilling screws of sufficient length to penetrate through tho sheathing a minimum of 3116" with self sealing washers. See Detail A. herein. The fasteners are to be placed at a spacing listed in Table A below starting 3" from panel end. TABLE A MAXIMUM DESIGN PRESSURES Roof Areas Field # PF.R A Perimeter and Corner' Maximum Design Pressures -60 sf - Maximum Clip Spa cin 16" o.c. o.c. �•b 1. Extrapolation shall not be allowed PC No.: 08-0507.05 .-„aK DADE`ou Ex--at-afioR-Date:-0696/-.3 MMM^•' ' � Approval Date: 06/26/08 Page 3 of 5 LIMITATIONS 1 The maximum designed pressure listed herein shall be applicable to all roof pressure zones (i.e. field, perimeters, and comers). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). 2. Panels may be rolls formed in continuous lengths from eave to ridge. Maximum lengths shall be as described in Roofing Application Standard RAS 133 3. All panels shall be permanently labeled with the manufacturer's name and/or logo, and the following statement: "Miami -Dade County Product Control Approved" or with the Miami -Dade County Product Control Seal as seen below. All clips shall be permanently labeled with the manufacturer's name and/or logo, and/or model. MIAWDADE COUNTY 4. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directoy for fire ratings of this product. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B-72 of the Florida Administrative Code. 6. Panels may be jobsite roll formed with machine model #RF 6272 from DMC Association of Regional Manufacturers. NOA No.: 08-0507.05 MIAM EADECOUA4TY- Expiration Date: 06/26/13 Approval Date: 06/26/08 Page 4 of 5 Overle PROFILE DRAWINGS DETAIL A M' Coverage uvenap END OF THIS ACCEPTANCE NOA No.: 08-0507.05 PiMMFDADE--MUKr Expi ra�tioa-Date: -06126/13 "' • • io Approval Date: 06/26/08 Page 5 of 5 MI -DARE COUNTY, FLORIDA METRO -DARE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE METRO-DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130-1563 (305)375-2901 FAX (305) 375-2908 PRODUCT CONTROL DIVISION (305) 375-2902 FAX (305) 372-6339 Richard Roe Atlas Roofing Corporation 2000 Riveredge Pkwy Suite 800 ATLANTA, GEORGIA 30328' NOTICE OF PROPOSED ACTION To: Members of the Board of Rules and Appeals and Atlas Roofing Corporation, Applicant In accordance with Dade County Administrative Order 10-3, which governs the product review process, the Product Control Division of the Office of Code Compliance, intends to issue a Product Control Notice of Acceptance to Atlas Roofing Corporation for FR 10 & FR 50 Fire -Retardant Slipsheet, No. 10-0603.15, to allow its use in Dade County and its municipalities. To: Members of the Board, of Rules and Appeals: The documentation being provided to you represents the recommendation of the Product Control Division of the Office of Code Compliance in regards to the submittal of Atlas Roofing Corporation for FR 10 & FR 50 Fire - Retardant Slipsheet, No. 10-0603.15. Under the provisions of Dade County Administrative Order 10-3, which governs the product review process. You must review this documentation. If within 20 days from the date of mailing, we do not receive any written objection stating the reason(s) for your disapproval, this product will be automatically approved. To: Atlas Roofing Corporation, Applicant The Product Control Division of the Office of Code Compliance, in accordance with Dade County Administrative Order 10-3, which governs the product review process, has issued this notice of proposed action and intends to issue a Product Control Notice of Acceptance for your FR 10 & FR 50 Fire -Retardant Slipsheet, No. 10-0603.15, to be used in Dade County and its municipalities, unless a member of the Board of Rules and Appeals or yourself has any objections. Should you not be in accord with this notice of proposed action and wish to appeal -our recommendation, you must make a written request, stating the reasons for your objection(s), to our office within 20 days of the date of mailing. Upon receipt of your written request a hearing date will be set so that you can present your objection(s) to the Board of Rules and Appeals. Sincerely, Jaime D. Gascon, PE Chief, Product Control Division DATE OF MAILING: 1012912010 MAILED BY: Internet email address: bcco@miamidade.gov Homepage: httpJ/www.miamidede.govlbulldingcode BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE Atlas Roofing Corporation 2000 Riveredge Pkwy, Suite 800 Atlanta, GA 30328 MIAMf I -DAD COUNTY, FLORIDA METRO-DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130-1563 (305) 375-2901 FAX (305) 375-2908 This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the-BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not. be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been.designed to comply with the High Velocity Hurricane Zone of the Flori ng Code. DESCRIPTI : FR 10 d FR 50 Fire -Retardant Slipsheet LABELING: Each unit shall bear a permanent label with the manufacturer's name or Iogo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. `1iERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distri utors and shall be available for inspection at the job site at the �eques� Ev HNE I V_ This renews NOA # 05-0602.03 and consists of pages I thrpd&Nssionai Engineer 32831 111 The submitted documentation was reviewed by Alex Tigera. 7205_ Elyse circle { Port St. Lucie, FL 34952-3212 I `` (772) 489-3035 fax NT- Expiration Date:40/20/I5 Approval Date: Page-1 of 3 r ROOFING COMPONENT APPROVAL Cateeory Sub-Catelorv: Material: Roofing Underlayment Fiberglass . SCOPE: This acceptance is for R 10 nd FR 50 Fire -Retardant Slipsheets as manufactured by Atlas _Roofing Corporation, as__escribed in this Notice_ of Acceptancei_for use. with_approved_prepared. roof assemblies. Designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. PRODUCT DESCRIPTION: Product FR 10 FR 50 Dimensions 48" x 250' rolls 48" x 105' roils Test - Suecification Physical Properties i Physical Properties EVIDENCE SUBMITTED: Test Agency Test Identifier Underwriters Laboratories Inc. OINK39956 99NK11055 97NK15618 06CA40873 07NK25337 09NK11233 MANUFACTURING LOCATION: L Meridian, MS. Product Description Non -Asphaltic fiberglass -based Fire - Retardant Slipsheet. Non -Asphaltic fiberglass -based Fire Retardant Slipsheet. Test Name/Report Date ASTM E-108 12/13/01 06/04/99 06/09/97 12/27/06 0l /30/08 04/30/10 NOA No.: 10-0603.15 Expiration Date: 10/20/15 Approval Date: Pa.ge_2_013 INSTALLATION: 1. FR 10 and FR 50 Fire -Retardant Slipsheets shall be installed in strict compliance with applicable Building Code. 2. FR 10 and FR 50 Fire -Retardant Slipsheets shall be installed with a minimum 2-inch head lap in a single layer fashion and fastened as required by the system assemblies NOA. 3, FR 10 and FR 50 Fire -Retardant Slipsheets are components used in roof assemblies. Roof assemblies are approved under specific assembly Notice of Acceptance requirements. 4. FR 10 and FR 50 Fire -Retardant Slipsheets may be used with any approved roof covering. Nottce of Acceptance listing FR 10 and-FR 50 Fire -Retardant Slipsheets as a component part of an assembly in the Notice of Acceptance. If FR 10 and FR 50 Fire -Retardant Slipsheets are not listed, a request may be made to the Authority Having Jurisdiction, (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. 5. FR 10 and FR 50 Fire -Retardant Slipsheets are a non -Asphaltic underlayment that may be - used as a fire -retardant for prepared roof assemblies. For fire classification of specific roof assemblies using FR 10 and FR 50 Fire -Retardant Slipsheets refer to a current Approved Roofing Materials UL Directory for fire ratings of this product. LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials UL Directory for fire ratings of this product 2. This acceptance is, for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code, LABELING: L. All packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo -to identify the Product Standard designation or the Miami -Dade County Product Control Seal as shown below. MIAMbDADE COUNTY BUILDING PERMIT REQUIREMENTS: 1. Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 1.2 A current Approved Roofing Materials UL Directory for fire ratings of this product. 1.3 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this material. END OF THIS ACCEPTANCE NOA No.: 10-0603.15 Expiration Date: 10/20/15 Approval Date: Page 3 of 3