Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSop_... Fee Due: MO. 6V I Recei t# Permit # St. Lucie County Building & Zoning SCA r" 2300 Virginia Avenue Ft. Pierce, FL 34982-5652 kv Tel. 772-462-1553 St eY FlOR10p' 4 UC/� APPLICATION FOR ROOF PERMIT Office Use Only ion Townshi Range Ma Pa e Z Lan s ,- .Initia s [!� _ 3. Description of Project or Work Activity: I-"r 6wpedaP 4. Total Roof Area (square feet): g,9 00 -9d 5. Roof Pitch: 6. Type of Roof: [Z Fiberglass Shingle ❑ Tar & Gravel ❑Other (specify) ❑Barrel/Tile Ceramic Modified Bitumen ❑ Wood Shake Shingle ❑ Metal R1N.O.A - Product Approval required for All Types of Roofing Material ❑ All Commercial Roofing Requires Design by an Engineer or Architect (two Sets) 7. Owner Information Name: JAe_ y'r< Address: 19 7 / ��+/ 1/� rr��ze.yr 6 4 e �1 City: FA �/ c,r'10 State: Zip: .3 b Phone: 9. Value of Construction: $600 8. Contractor Information `� FL Reg/Cert #: CC-4- ! 3 Z 6 S% T County Cert#:� Business Name: _AX 9-90AvS Phone 41-9? Fax :e?'7 ^ 7 _76.3 Note: Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval OWNER'S AFFIDAVIT:' I certify that all of the information contained in this application is correct and that all work will be done in compliance with all applicable laws regulating construction and zoning. PRINT QUALIFIERS/OWNERS NAME��I SIGNATURE OF QUALIFIER/OWNER STATE //OF FLORIDA, COUNTY OF / ACKNOWLEDGED BEFORE ME THIS DAY OF s to 5rr, 200, BY 9u t,e_S L iS OG- WHO IS PERSONALLY KNOWN TO ME OR WHO HAS PRODUCED AS IDENTIFICATION. Lse�a_l) SIGNATU ' OF VOTARY TYPE OR PRINT NAME OF NOTARY NOTARY PUBLIC-S'Nft OF FLORIDA Donna I Malizia TITLE: NOTARY JVBLIC COMMISSION NUMBER___* Commission#DD392371 St. Lucie County Roof Permit Application rev. 7/18/05 dmg Expires: FEB. 02, 2009 Bonded Thru .atlantic Bonding Co., Inc. Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1148 http://stiucieco.gov/ce Issued: 09/26/2007 Conf #; 711 BUILDING PERMIT Permit #: SLC- 0709-0332 Page 1 Job Location: 2809 PLACID AVE City: FORT PIERCE Permit Type: Roof Job Description: TEAR OFF FIBERGLASS SHINGLE AND REROOFING WITH FIBERGLASS SHINGLE & MODIFIED BITUMEN. TOT AREA 2400SF 5/12P & FLAT. Subdiv: Corso Courts Lot: 2 Block: Contractor ROE E DOUGLAS Parcel: 2421-606-0002-000/3 CODE RED ROOFERS INC (772) 287-2829 3341 SE SLATER STREET STUART, FL 34997 Property Owner JERKY JACKSON 1271 SW EVERGREEN LANE PALM CITY, FL 34990 Setbacks Left: Right: Number of Units: 1.00 Floors: 1 Minimum Floor Elevation: Job Value: $ 3,000.00 Front: Rear: Buildings:), Flood Map: Flood Zone: (772) 215-1449 Zoning: RS-4 Square Footage: 0.00 Elev: Permit holder acknowledges through acceptance of this permit that separate permits must be obtained as required by the Florida Building Code including those for all electric, plumbing, mechanical, roofing, and structural work. Further, he/she acknowledges responsibility to comply with all requirements of the 2004 Florida Building Code. NOTICE: In addition to the requirements in this permit, there may be additional restrictions applicable to this property that may be found in the records of this County, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. s:553.79(10), F.S. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR BUILDING IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. s.713.135, F.S. Christopher Lestrange /7` (y Building Official Date For Automated Inspections, Call (772) 462-1261 . For Questions, Call (772) 462-2172 St. Lucie County Land Development Code Section 11.05.01 (A) (2) states; Building Permits shall expire and become null and void if work authorized by such Building Permit is not commenced, having called for and received a satisfactory inspection, within six (6).months from the date of issuance of the permit, or if the work is not completed within 18 months (permit by contractor) or 24 months (permit by owner) from the date of issuance of the Building Permit. EDWIN M. FRY, Jr., CLERK OF THE CIRCUIT COURT - SAINT LUCIE COUNTY FILE # 3113585 01 'WOK 2885 PAGE 1145, Recorded 09/26/,' �' s, at 03: 09 PM AFTER RECORDING -RETURN Tr^• PERMIT NUMBER: Thi.Sirna i. r.•: �.: ni �o,,w:u^duel; uil:: NOTICE OF COMMENCEMENT The undersigned hereby given notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida statutes the following information is provided in the Notice of commencement. 1. DESCRIPTION QF PROPERTY (Legal description and street address) TAX FOLIO NUMBER:-77•R I rira O^ODdz^ OOC 3 2. GENERAL DESCRIPTION OF IMPROVEMENT: ,Vr-m&Ve aoll /�eo�te rcDo 3. OWNER INFORMATION: a. Name G o b. Address 19 7 f '9&' E t'd r hi. fm el gIX, f1 O c. interest in property dL--' e.'• d. Name and address of fee simple titleholder (if other than owner) 4. CONTRACTOR'S NAME)) ADDRESS A PHO� NU BER: D p n 13.9 `// .SAC SIa Ter -}17rce � hcQr � /�L � 99 7 5. SURETY'S NAME, ADDRESS AND PHONE NUMBER AND BOND AMOUNT: 6. LENDER'S NAME, ADDRESS AND PHONE NUMBER: 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13 (1)(a) 7., Florida Statutes: NAME, ADDRESS AND PHONE NUMBER: 8. In addition to himself or herself, Owner designates the following to receive a copy of the Lienor's Notice as provided in Section 713.13 (1)(b), Florida Statutes: NAME, ADDRESS AND PHONE NUMBER: 9. Expiration date of notice of commencement (the expiration date is I year from the date of recording unless a different date is specified) 20_ Print Name and Provide Signatory's Title/Oftice State of Florida County of / The foregoing instrument was acknowledged before me this .26 day of !1 ah e*t —4.- 20-2__�7. By —J C tr* A as DLriy ,,— (Name of pp(on) (Type of authority... e.g. Owner, officer, trustee, attorney in fact) For (Name of party on behalf of whom instrument was executed) Pers a y Known vor produced the following type of ID: NOTARY PUBLIC-SIME OF FLORIDA POAjlvA Donna & Malizia K MAw i4 Commission#DD392371 (Printed Name of Notary Public) (Signature of otary Public) (Se.16 Expires: FEB. 02, 2009 on fe Thbru Atlantic Bonding Co., Inc. t�u Under penalties of perjury, I declare that I have read the foregoing and that the facts in it are e o t of my knowledge and belief (section 92.525, Florida Statutes). .. Signature(s) of Owner(i) or Owner(s)' Authorized ORcer/Director/Partner/Manager who signed above: By: /'G1s By R lalURgYIIR mding) n�Terr nr ea nmin• ST. .To, T,: E: z C By: Da �f. Code Compliance Division 2300 Virginia Avenue Ft. Pierce, Fl- 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 http://stiucleco.gov/ce Date: 26 September 2007 Job Address: 2809 PLACID AVE Receives} By: spellsv Paid With: CK Paid By: JERRY JACKSON Building �s Receipt Sign: Receipt#: 0000057694 ermit Number: SLC- 0709-0332 Amount: $180.00 :redit Card Number: Check Number: 2600 SEP, 24. 2007 2:23PM-RRADCO SUPPLY 0,5�2.4226 P. 1 I � F COB%% LE FT MIAMI BUU..AING CODE COMPLLANCE OFFICE (i3CCO) PRODUCT CONMOLDIVISION NOTICE OF ACCEPTANCE ff OA) GAIT Materials Corp. 1361 Alps Rd. Wayne, NJ 07470 MM=-DADE COUNTY, FLORIDA MEMO -DARE R AOLER BUI>~DING 14D wE,ST FuGuR STPEET, SUITY,1603 M7ANZ FLORIDA 3313NI569 (305) 375-2901 PAX (305) 375.2908 SCOFF: This NOA is being issued under the applicable rules and regulations governing the use of construction materials: The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having jurisdiction (AIM. This NOA shall not be valid after the expiration date stated below, The BCCO (In Miami Dade County) and/or the AM (in areas other than Miami Dade County) reserve the right To have this product or material tested for quality assurance purposes, If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BCCO reserves the right to revoke this acceptance, if it is determined by BCCO that this prodilet or material fails to meet the requirements of the applicable building code. This product is approved as described hereia, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DES CRIPTION rTimb7e lizre30 RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code .negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process, Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA, ADVERTISEMENT- The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion, of the NOA is displayed, then it shall be done in its entirety. INSPECTION. A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building OfficiaL This NOA renews and revises NOA #05-1115.09 and consists of pages 1 through 4. The submitted documentation was reviewed by Alex Tigers. NOA No.:06-1211.02 - _ Expiration Date: 02r21l12 THESE PLANS AND ALL PROPOSED WORK Approval Date-, 02108/07 ARE SUBJECT To ANY CORRECTIONS Page I of REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. SEP. 24, 2007 2:24PM RRADCO SUPPLY NO. 4226 P. 2 ROOFING Symm APPROVAL Cateeory: Roofing Sub-Cateo:_ 07310 Asphalt Shingles Materials Dimensional ' Deck Tvae• Wood I. SCOPE This revises GAF Timberline 30 as manufactured by GAP Materials Corp described in Section 2 of this Notice of Acceptance- - 2. PRODUCT DESCRIPTION Product Dimensions Test Product Descri tioxx Specifications Timberline 30 13W'x 3931$ ' TAS 110 Piberglass reinforced heavy weight asphalt roof shingle, with a laminate profile 3. EVIDENCE SUBMITTED: Test Auency Test Identifier Test Name/Report Date Underwriters Laboratories, Inc. TAS 107 01NK45803 04/13194 Center for Applied E►t;ineerhig TAS 100 257989 04/01/97 Center for Applied Engineering ASTM D3462 257989 05/13/97 PRI Asphalt Technologies, Inc. ASTM D3462 GAP-101-02-02 11/02/05 PRI Asphalt Technologies, Inc. TAS 100 GAF-044-02-01 01/13104 PRI Asphalt Technologies, Inc, TAS 100 GAP-101-02-01 11/09/05 PRI Asphalt Technologies, Inc. TAS 100 OAF-116-02-02 03/23/06 Underwriters Laboratories, Inc. TAS 107 04NK04273 . 02/20/04 Underwriters Laboratories, Inc. Modified ASIM D3161 05CA42840 11/11105 Underwriters Laboratories, Inc. TAS 107 06NX05159 08/09/06 Underwriters Laboratories, Inc. ASTM D3462 06NR05159 08/09/06 4. LOUTATIONS 4.1 Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 4.2 Shall not be installed on roof mean heights in excess of 33 ft, 4.3 All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B-72 of the Florida Administrative Code. 5. INSTALLATION 5.1 Shingles shall be installed in compliatce with Roofing Appiicatiozx Standard RAS 115. 5.2 Flashing shall be in accordance with Roofing Application Standard RAS 115 5.3 The 7Xtutfaeturer shall provide clearly written application instructions. 5.4 Exposure and course layout shall be in compliance with DeWl'A', attached. 5.5 Wailing shall be in compliance with Dctail'B', attached. _ o NOA No.:06-1211.02 Expiration Date: 0212MZ Approval Date: 02/08/07 Page 2 of 4 ^ 8EP.24. 2007 2:24PM BRADCO SUPPLY NO.4226 P. 3 6. LABELING 6.1 Shingles shrill, be labeled with the Miami -bade Logo or the wording "Miami -Dade County Product Control Approved". 7. BUILDING PERMIT REQUIRMaNTS 7.1 Applic=ion tof baildlug pennit b11ai! be accowpur.ied by copies of the following: 7.1.1 This Notice of Acceptance. 7.1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. 8. MANUFACTURING PLANTS 8.1 Tampa, IFL 8.2 Michigan City, IN 8.3 Mobile, AL DETAIL A. 0 NOA No.:06-1211.02 Expiration Date: 02 21112 ApprovaI Date: 02/08/07 Page 3 of 4 SEP. 24. 2007 2; 24PM BRADCO SUPPLY NO.4226 P. 4 1; DETAm B . 39-3/8" — 6 fasteners 7'� �� _7�^ Front Side (Maximum Slope 12:12) a�-aiv i 6 fasteners 72" - l 72" 8" 5-5 L Front Side (Maximum Slope 21:12) Tab Sealant i" 2" Back Side END OF TEIS ACC1t;iMANCE Release Tape Release Tape J 3l$" f � � NOA No.:Ob-1211A2 Expiratimi Date: O2(2VI2 Approval Date: 02108/07 Page 4 of 4 SEP, 25. 2001 10:40AM BRADCO SUPPLY N0.424 '�j, M I A NI I•OADE BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL. DIVISION NOTICE OF ACCEPTANCE (NOA) Johns Manville Corporation 71717`b Street Denver, CO 80202 rdIAMI-DADS COUNTY, FLORIDA METRO -DADS FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA33130-1563 (305) 375-2901 PAX (305) 37s-29o8 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AM. This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami bade County) and/or the AIHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AIlJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. FORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County product Control Division that this product or material fails to sleet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High velocity .Hurricane Zone of the Florida Building Code. DESCRIPTION,*o ns Manvrl e} 14Zo ifie itumen dfingrSystextisrCiver Wood�>i ecl LABELING.- Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County product Control Approved", unless otherwise doted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERlIMATION of dais NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endozsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. AIIVERTISOM)ENT: The NOA number preceded by the words Miami bade County, Florida, and followed by the expiration data may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION; A copy of this entire NOA shall be provided to the user by the Manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No. 03-0212.01 and consists of pages 1 through 16. The submitted documentation was reviewed by Jorge L. Acebo a NOA No.: 06-0417.09 _ Expiration Date; 06/14/11 Approval Date: 06/22/06 Page 1 of 16 THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE COPES, SEP.25,2007 10:40AM RRADCO SUPPLY a NO.4246 P. 3 ROOFING ASSEMBLY APPROVAL Cates Roof1mg Sub-Catezorv: APP Modified Bitumen Deck Type. Wood Maximum Desi Pressure -52.5 psf Fire Classification; See General, Limitation #1 TRADE NAILS OF PRODUCTS MANtrF'ACTMD OR LABELED BY APPLICANT: TABLE Test Product Product Dimensions Specification _ Description IM APP Base 150 sq, ft. roll ASTM D 5147 APP modified asphalt, fiberglass reinforced, smooth surfaced base skeet. APPeX 4S 32.$' x 3.28; 90 ASTM D 6222, APP modified asphalt, polyester lb_ roll type L grade S reinforced, smooth surfaced membrane. APPeX 4.5M 32.8' x 3.281; 90 ASTM D 6222, APP modified asphalt, polyester lb. roll type I grade G reinforced, mineral surfaced membrane. APPeX 4.5MFR 32.8' x 3.28 ; 90 ASTM D 6222, APP modified asphalt, polyester lb. roll type I grade G reinforced, fire -retardant, mineral surfaced membrane, APPNX 180 32.8' x 3.28; 90 ASTM D 6222, APP modified asphalt, polyester lb. roll type I, grade G reinforced, smooth surfaced membrane. Bicor MF'R 39 3/8" x 34' ASTM D 6223 APP modified asphalt, polyester / glass reinforced, granule surfaced membrane. Tricor MFR 39-3/8" x 34' ASTM D 6223 APP modified asphalt, polyester / glass reinforced, granule surfaced membrane. Bicor S 39-3/8" x 34' ASTM D 6223 APP Modified asphalt, polyester / glass reinforced, smooth surfaced membrane. Tricor S 39-3/8" x 34' ASTM D 6223 APP modified asphalt, polyester / glass reinforced, smooth surfaced membrane. PermaPly 28 36' x 108'; ASTM D 4601 Type If asphalt impregnated and coated 72 lb, roll glass fiber base sheet NOA Noa 06-0417.09 Irxpiration pate: 06/14/11 Approval Date., 06/22lo6 Page 2 of 16 SEP,25.2007 10:41AM ,RRADCO SUPPLY NO.4246 P. 4 a Frodrtct Dimensions Test product S Wfl aft �DesC�on Ventsulation 36" x 36' ASTM D 4897 Heavy duty fiber glass base sheet Type 11 impregnated and coated on both sides with asphalt with or without fine mineral stabilizer. JM Topgard Type B ASTM D 1227 Fire rated, fibered, non -asbestos, clay water base asphalt emulsion. JM .Fibrated Aluminum ASTM D 2824 Fire rated, fibered, non -asbestos Roof Coatingaluminum coating: JM Premium Fibered ASTM D 2824 Fire rated, fibered, non -asbestos asphalt Aluminum hoof Coating aluminum coating. APPROVED INSULATIONS: TABLI; 2 Product Name Product Description Manufacturer (With Current NOA) ENRGY 2, ENERGY 3, PSI 25 Xsocyanurate insulation. Johns Manville ENRGY 2 Composite P*isocyanurate insulation laminated to Johns Manville perlite. ENRG'Y 2 Plus Polyisocyanurate insulation laminated to Yohns Manville wood fiber. Fesco Foam, DuraFoam Isocyanurate Yusulatxon with perlitc facer Johns Manville Retro Fit Board, Dura$oard A high -density perlite roof insulation. Johns Manville l:esco Board Rigid perlite roof insulation board. Johns Manville Fiber Glass Roof Xnsulation Fiberglas roof insulation. Johns Manville ACFoam 11 Isocyanurate Insulation Atlas Roofing Corp. Wood fiberboard Regular wood fiber insulation Generic High, Density Wood Fiberboard High Density Wood Fiber insulation board. Generic PerIite Jztsulation Board Ferlite Insulation Generic Type X Gypsum Gypsum Wallboard Generic XFS Extruded polystyrene Generic Structodcek High Density Wood Fiber insulation board. Masonite c NOA No.: 0"417.09 " - Expiration Date: 06/14/11 Approval Date: 06/22/06 Page 3 of 16 ` SEP. 25. 2007 10:41AM _.RRADCO SUPPLY N0.4246 P. 5 APPRowD FASTENEIIS; TASLe 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 1. Ultrapast lusulation fastener for wood Johns Manville and steel. 2. U1traFast ASAP Pre -assembled Insulation Johns Manville fastener and plate 3. UltzaFast Metal Plate Galvalume AZ55 steel plate 3" square & Johos Manville 3" round 4. Olympic Fastener #12 & Insulation fastener Olympic Mfg. Group #14 5. Olympic Fastener ASAP Pre -assembled Insulation Olympic Mfg. Group fastener and plate 6, Olympic G 2 Galvalume AZ55 steel plate 3.5" round Olympic Mfg. Group 7. Olympic Standard Galvalume AZ50 steel plate 3" round Olympic Mfg. Group 8. Tru-Fast Insulation fastener for steel The Tru-Fast Corp. and wood decks 9. Txu-Fast Plates Galvalume AZ55 steel plate 3" round The Tru-Fast Corp. EvmENCE SUBMITTED: Testacy Vest Identifier Description Date Factory Mutual Research Corp. J.L OXOA9.AM Wind Uplift 03/25/94 J-1.OW6A2.AM Wind Uplift 02/05/93 J.L OX7A4.AM Wind Uplift 08/26/93 J.I, 3001482 08/11/98 J.1.3002823 04/01/99 J.L 3003468 02/02/00 J.T. 3007148 04/19/00 3009499 4470 04/04/01 3011248 4470 11/01/02 3012974 4450 06/03/02 Underwriters Laboratories, Inc. R-10400 Published Annually Exterior Research & Design, LLC #4361-2.04.97-1 TAS 114(J) — Wind Uplift 04/15/97 10390A.I2.97-1 TAS 114Q) — Wind Uplift 12/15/97 10390A.10.97-1 TAS 114(J) — Wind Uplift 10/15/97 10391.01.03 TAS 114(J) & TAS 117 (B) 01/29/03 n NOA No.; 06-0417.09 Expiration Date: 06/14/11 Approval Date: 06/22/06 Page 4 of 16 SEP, 25. 2007 10;41RM RRADCO SUPPLY N0. 4246 P. 6 r Membrane Type: APP . Deck Type 11[: 'Wood, Non -Insulated Deck Description: '9/3z" or greater plywood or wood plank System Type E: Base sheet mechanically fastened, All General and System limitations apply. Base Sheet: (Option #I) Oue ply of JM A PP Base, Permaply 28, GIasbase Plus or Ventsulation mechanically fastened to the deck with JM Ultt2Past, Olympic or Tru-Fast metal platds and fasteners at a 4" side lap 12" o.c. and two rows staggered in the center of the sheet 18" O.C. (Max'Mum Design Pressure -4Spsf--See General Limitatfon #9.) (Option #2) Minimum; two plies of JM PermaPly 28 or Ventsulation simultaneously fastened to the deck lapped 4" and fastened with approved roofing nails and tiff caps 9" o.c. at the 14p and two rows staggered in tho center of the sheet 12" o.c_ (Maximum Design Pressure—S2.S,psf—,See (reneral Lim tation 47.) (Option #3) Minimum two plies of JM PetmaPly 28 or Ventsulation simultaneously fastened to the deck with JM Ultrafast fasteners and Metal Plates spaced 9" o.c_ in a V' lap and 12" o.c. in tWO staggered rows in the center of the sheet. (Maximum Design Pressure 52. S psf -- See General Limitation #7.) Ply Sheet: (Optional) One or more plies of JM AP? Base, APPeX 4S or APPeX 180 beat welded to base sheet. Membrane: One or more plies of APPeX 4S, APPeX 180, APPeX 4.5M or APPeX 4.5 MR heat welded. Surfacing: (Optional) Install one of the following for all systems that do not achieve acceptable fire ratings through the use of FR membrane sheets. 1. 400 lb./sq. gravel or 3001b./sq. slag in a flood coat of approved mopping asphalt at a rate of 60 lb./sq. 2. Karnak 97, Kamak 97 AF, Monsey Premium Long Life Aluminum Roof Coating Asbestos Ftee or Monsey Prograde Aluminum, JM Topgard Type A, Topgard Type D, rM Aluminum RF CT, Grundy AL MB aluminum coating at a rate of 1-1/2 gal/sq Monsey Aquabrite, Gardner asphalt emulsion, APOC Sunbright 400 or Henry 229 Aluminum Emulsion at 2% gal/sq or APOC 212 Aluminum Roof Coating at 3 gal/sq. 3. Grundy 20 F asphalt emulsion, Endure Asphalt Emulsion, APOC 302 or 302 AF applied at 2'/s gal/sq with optional 60 lbs./sq. of roofing granules embedded in wet coating. Maximum Design Pressure: See Fastening Options Above o NOA No.: 06-0417.09 w Expiration Date: 06/14/11 Approval Date: 06/22/06 Page 15 0116 SEP, 25, 2007 10:42AM ,_RRADCO SUPPLY N0. 4246 P. 7 WOOD Y FcK Mum Y,>(1V,YYx'ATIONS: 1 A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet. GENF, AL LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a eumat Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-401bs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum, 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is frilly mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side Iap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable, A 6" break shall be placed every 12'in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be Wited to a maximum design pressure of-45 psf. S. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 2751bf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 2751bf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117, 7. Perimeter and comer areas shall comply with the, enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Rooting Application Standard RAS 117. Calculations prepared, signed and seated by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) S. All attachment and sizing of perimeter nailers, metal profile, andlor flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended comers and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) END OF THIS ACCEPTANCE ' NOA No.: 06-0417.09 Y Expiration Date., 06/14/11 Approval bate: 06/22/06 Page 16 of 16