Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SUBMITTED PAPERS
Receipt# Permit, Y St. Lucie County Building & Zoning Department ~0 SCANNED 2300 Virginia Avenue BY Fort Pierce, FL 34982 ��ORt St. Lucie C17(.,nty 772-462-1553 APPLICATION FOR REPLACEMENT OF WINDOWS, SKYLIGHTS, DOORS & OVERHEAD GARAGE DOORS 1. LOCATION/SITE ADDRESS: "\ \ \ D(- SECT jb� TWP1&0 RNGLZA MAP ZNG LU INIT 2. PARCEL ID NUMBER: �`�i'O� - SG 1 — q� 3. DESCRIPTION OF PROJECT OR WORK ACTIVITY: e_C�._`� (�� (1 �e,��act, 4. TYPE OF STRUCTURE: ❑ SFR 1Y OTHER r 5. OWNER INFORMATION 6. CONTRACTOR INFORMATION Name: �(�i Ff' �(��X' �— FL Reg/Cert #: 1Qj� Address: County Cert#: City: ' t' C-Cc, State: F I Business Name: Ca 2 Zip: Phone: -1- 9qj Phone4(oC-)-_](Dax y �()Q -� p�j� Product Table 1606.213 ** 15' maximum height Minimum Design Pressure Design Pressures Manufacture Model Number NOTICE OF ACCEPTANCE # FLORIDA # 130 mph 140 mph Windows & Skylights Exposure B 40.7 47.2 Exposure C ** 1 49.2 1 57.1 Swing & Garage Doors Exposure B 1 38 44 ty $ - �Q�C*pu_, �JHDGL t �1 ` ,(�1,- Exposure C ** 45.9 53.2 7. VALUE OF CONSTRUCTION: $ LCcj� CZ OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in compliance with all applicable laws regulating construction and zoning. PRINT R4MLTJI� ST'OTE 7F FLORWA, COUNTY OF 20D BY I• SIGNATURE Of NOTARY SIGNATURE OF QUAL R/OWNER ACKNOWLEDGED BEFORE ME THIS 'Z� DAY OF /LZMPERSONALLY KNOWN T AS IDENTIFICATION. TYPE OR PRINT NAME OF NOTARY COMMISSION NUMBER OR WHO HAS PRODUCED rove w� Notary Public State of Floft Janet Ru'd Comm seam DD59583o °f ^ Expires 09/17/2010 Window, Skylight, Doors, Garage Door permit application 7/18/05 ding �,�CirfitG //Oc Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1148 http://stiucieco.gov/ce Issued: 09/25/2007 Conf #: 657 BUILDING PERMIT Page 1 Job Location: 911 BUCKEYE DR City: Permit Type: Building (Miscellaneous) Job Description: TEAR DOWN & REPLACE 9 X 7 GARAGE DOOR. Subdiv: White City Lot: 7 Block: Contractor MILLER DENVER R Permit #: SLC- 0709-0316 FORT PIERCE Parcel: 3404-501-0547-010/6 D & D GARAGE DOORS OF PSL INC (772) 460-7630 500 KITTERMAN ROAD PORT ST LUCIE, FL 34952 Property Owner MICHAEL R. STUART (772) 464-9891 911 BUCKEYE DR FORT PIERCE, FL 34982-7215 Property Owner JENNIFER STUART 911 BUCKEYE DR FT PIERCE, FL 34982 Setbacks Left: Right: Front: Rear: Zoning: RS-3 Number of Units: 1.00 Floors: 1 Buildings: 1 Square Footage: 0.00 Minimum Floor Elevation: Flood Map: Flood Zone: Elev: Job Value: $ 600.00 Permit holder acknowledges through acceptance of this permit that separate permits must be obtained as required by the Florida Building Code including those for all electric, plumbing, mechanical, roofing, and structural work. Further, he/she acknowledges responsibility to comply with all requirements of the 2004 Florida Building Code. NOTICE: In addition to the requirements in this permit, there may be additional restrictions applicable to this property that may be found in the records of this County, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. s:553.79(10), F.S. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR BUILDING IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. s.713.135, F.S. Christopher Lestrange Building Official Date For Automated Inspections, Call (772) 462-1261 For Questions, Call (772) 462-2172 St. Lucie County Land Development Code Section 11.05.01 (A) (2) states; Building Permits shall expire and become null and void if work authorized by such Building Permit is not commenced, having called for and received a satisfactory inspection, within six (6) months from the date of issuance of the permit, or if the work is not completed within 18 months (permit by contractor) or 24 months (permit by owner) from the date of issuance of the Building Permit. ��.. Building Code Compliance Division Receipt 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 hftp://stiucleco.gov/ce Date: 25 September 2007 Job Address: 911 BUCKEYE DR Received By: spellsv Paid With: CK Paid By: GARAGE DOOR DEPOT Receipt #: 0000057661 ermit Number: SLC- 0709-0316 Amount: $80.00 :redit Card Number: Check Number: 8013 Sign: CLOPAY MODELS 4300, 4301, 4310, 4400, 4401, HDG. HDGL (UP TO 8.0" HIGH) CLOPAY MODELS H400, H401" H300, H301. H310 (8'3" TO 12'0" HIGHj® HOLMES MODELS 66, 67, 68 (UP TO 8'0" HIGH)® REINFORCEMENT PLATES ATTACHED TO DOOR SKIN SWCONE F REINFORCEMENT PLATES ATTACHED TO DOOR SKIN (NH PATENTED TOG-L-LOG FRONT ANC WITH PATENTED TOG-L-LOC SYSTEM (NOT VISIBLE FROM OUTSIDE) (NOT VISIBLE FROM OUTSIDE) (2) INTERMEDIATE REINFORCEMENT —i I--2` THICK (2) INTERMEDIATE REINFORCEMENT PLATES PER PER SECTION. ATTACHED W/ TOG- .. I I SECTION ATTACHED WITH TOG-L-LOC SYSTEM SYSTEM (NOT VISIBLE FROM OUTSIDE) COPY (NOT VISIBLE FROM OUTSIDE) -� A ---A I L I--� MAX. DOOR WIDTH = 9'-0" -� / INSIDE FLFVATION LOCATION OF OPTIONAL VENTS MAXIMUM VENT OPENING: 60 IN' TABLE 1 DOOR HEIGHT NUMBER OF SECTIONS• 6 0" TO 7 0 4 76 TO B9 5 0 jg'6 20 109 TO 1 7 I IS 0 N o LUCK POSITION (BOTH tl p SIDES) TWO POINT LOCKING HAS BEEN i TESTED PER REQUIREMENTS OF o rc SECTION 12.1 OF TAS 202. LOCKS HAVE 5/8" o MIN. ENGAGEMENT. DOOR TESTED FOR FORCED ENTRY WITH BOTH OUTSIDE KEYED LOCK AND INSIDE SLIDE BOLT LOCK OPTIONS (SEE LAYOUT OF EACH LOCK FOR DETAILS). END SUDS BOLT STILE LOCK ENGAGES INTO VERTICAL TRACK. ONE LOCK EACH SIDE SIDE OF DOOR. INSIDE SUDE BOLT LOCK OPDON A� �� Te• 21 Hx HORIZONTAL TRACK SUPPORT DOOR INSTALLER (TO S 13 GA. GALV. STEEL FLAG BRACKET. EACH FASTENED TO WOOD JAMB WITH (3) 5/16".1-5/8WOOD LAG SCREW.. u z o 0 N x U XS "X4` w 0 "%3" J "L Sam HINGE DETAIL SEE INTER. HIN Ai DEMN. LOCK POSTION (BOTH SIDES) TWO POINT LOCKING RAS BEEN TESTED PER REQUIREMENTS OF SECTION 12A OF TAS 202. LOCKS HAVE 5/B' MIN. ENGAGEMEM. DOOR i I ' TESTED FOR FORCED ENTRY WITH BOTH OUTSIDE KEYED 1' I„ Imo__=__�)1 ii'=L____ 1 LOCK AND INSIDE SUDE BOLT LOCK OPTIONS (SEE TONGUE AND GROOVE JOINTS. LAYOUT OF EACH LOCK FOR DETAILS). A MAX. DOOR WIDTH = 9'-0` -{ INSIDE ELEVATION INSTALLER MODEL RETAIL 4300 H300 HDG. 66 27 GA. FXT. SKIN SHORT RAISED PANEL 4400 H400 N/A 24 GA. EXT. SKIN SHORT RAISED PANEL PANELSKINFLUSH 430T H301 68 27 GA. EXT. SKIN; FLUSH PANEL 310 HDGL, 67 27 GA. UT. SKIN; WIDE S D PANEL LOCATION OF OPTIONAL VENTS MAXIMUM VENT OPENING: 60 IN' END STILE LOCK BAR OUTSIDE GUIDE HANDLE LOCK BAR ENGAGES IN TRACK ON LHR TOP BRACKET OUTSIDE KEYED LOCK EACH SIDE ATTACHED WITH (2) LOCK BAR LOCKING OF DOOR. SELF TAPPING SCREWS DOUBLE HORIZOMAL TRACK DOUBLE TRACK LOW HEADROOM OPTION THE 2.6 VERTICAL WOOD JAMBS ARE TO BE GRADE 2 OR BETTER YELLOW PINE. NO LOAD IS TRANSFERRED TO THE HORIZONTAL (TOP) JAMB. ALL JAMB FASTENERS MAY BE (BUT NOT TRACK CONFIGURATION REQUIRED) COUNTERSUNK TO PROVIDE A FLUSH MOUNTING SURFACE NQIE: SUPPORTING STRUCTURAL 2x6 WOOD JAMB ELEMENTS SHALL BE DESIGNED BY A REGISTERFD PROFESSIONAL ENGINEER FOR WIND LOADS SHOWN ON THIS SNAP LATCH ENGAGES 27 GA MIN. G-90 (OR EQUIVALENT) ONTO VERTICAL TRACK. EXTERIOR STEEL SKIN WITH ONE SNAP LATCH BACKED -ON POLYESTER PAINTED EACH SIDE OF DOOR. TOP COAT APPLIED TO BOTH SIDES OF STEEL SKIN. YIELD 28 KSI (MIN). OUTSIDE END KEYED STILE HANDLE INSIDE HANDLE OUTSIDE KEYED LOCK ^ omrmr®armi�ml�ss oml�mr®©rmimm�ss �m�Tr�ar�rm���ss r��e�r�er±am��s IL9C.]iiR.SiriSYiDir7 E$�B�R'SYl�if.� Eslr EDIT bl]r Fi3� �:r,trs �1�0 RICiIBiO-� ii�fi➢iT�7�:iS��i�fi�iGT� '. f il�:1i iGfiL iSIrL9 iG7 fx2li FSi f:F]I� f i7iY IB3�' IlBillRl��iG>iE���� STOP MOULDING BY DOOR INSTALLER (TO SUIT) r(18 GA. GALV. STEEL END STILE END STILES HELD BY HINGE SCREWS) 1.95` THICK. 1N DENSITY EXPANDED POLYSTYRENE FOAM INSULATION LAMINATED TO BOTH EXTEROIR AND INTERIOR SKINS. FOAM INSULATION IS AN APPROVED FOAM PLASTIC (PER FBC 2612.2) AND MEETS REQUIREMENTS OF FBC/IBC 2603.4.1.9. 12 GA. GALV. STEEL TOP ROLLER BRACKET. EACH BRACKET ATTACHED W/(4) /14x5/8` SHEET METAL SCREWS. - 14 GA. GALV. STEEL END HINGE. EACH FASTENED TO END STILES W/(4) /14x5/8" SHEET METAL SCREWS AND (4) 1/4`x3/4` SELF TAPPING SCREWS 3` TALL x 20 GA GALV. STEEL U-B4R. TWO PER DOOR SECTION. ATTACHED WITH (6) 1/4"x3/4" SELF TAPPING SCREWS PER U-BAR, (2) ON EACH END & (2) AT CENTER HINGE LOCATION, 27 GA. INTERIOR STEEL GALV. SKIN WITH A BAKED -ON PRIMER AND A BAKED -ON POLYESTER PAINTED TOP COAT APPUED TO BOTH SIDES OF STEEL SKIN. 13 GA. GALV. STEEL BOTTOM BRACKET. ATTACHED WITH (2) /14x5/8` SHEET METAL SCREWS. ALUMINUM EXTRUSION & VINYL WEATHERSTRIP. 0 (4) 1/4"x3/4" SELF TAPPING SCREWS 14 GA END HINGE IS GA. INTERMEDIATE HINGE" 14 CA INTER. HINGES USED ON 24 GA. EXTERIOR SKIN DOOR MODELS A i 2 x3 LAG SCREWS DN 24 CENTERS. 1 O.D. WASHER REQUIRED. LAG SCREWS MAY BE COUNTERSUNK (BUT NOT REQUIRED) TO PROVIDE A FLUSH MOUNTING SURFACE. HORIZONTAL JAMBS DO NOT TRANSFER LOAD. DRAWING. VERTICAL JAMB ATTACHMENT (C-90 BLOCK OR 2" GALV. STEEL TRACK, TRACK THICKNESS: .060` T((Y3P. 2-1/2'x12 GA GALV. STEEL TRACK BRACKET(5 El PER S 6) TRACK BMCKETS PER SIDE (UP TO 812'HHIGH). 2.000 PSI MIN. CONCRETE COLUMN): 12 GA. GALV. STEEL TRACK 3/Bi4" SLEEVE ANCHOR BOLTS ON 18-1/2" CENTERS BRACKET FASTENED TO WOOD (C-90 BLOCK) OR 24" CENTERS (2,000 PSI CONCRETE) JAMB WITH ONE 5/16'x1-5/8" OR 1/4"x4` TAPCON SCREWS ON 15-1/2" CENTERS WOOD LAG SCREW PER BRACKET. (2,ODD PSI CONCRETE). WASHERS INCLUDED WITH SLEEVE 18 GA. 2` GALV. STEEL TRACK FASTEN MIN. GALV. STEEL CENTER HINGE ANCHORS, 1" O.D. WASHERS REQUIRED WITH TAPCONS. D TO I(JSIDE SKIN W/(4) ANCHORS MAY BE COUNTERSUNK (BUT NOT REQUIRED) FASTENED TO TRACK BRACKETS. EACH14x5/8 EACH BRACKET ATTACHED WITH ONE SHEET METAL SCREWS TO PROVIDE FLUSH MOUNTING SURFACE. HORIZONTAL JAMBS DO NOT TRANSFER LOAD. 1/4`x5/9- BOLT & NUT 0 14 GA GALV. STEEL END HINGE TWO 1/4" RNEIS. FASTENED TO END STILES W/(4) EACH THIS DOOR M ETS R EXCEEDS THE DESIGN LOADS FOR THE WIND SPEEDS LISTED BELOW CORDING TO THE FLORIDA BLDG. CODE OR IBC (ASCE7) FOR THE FOLLOWING CONDITIONS: 1) ENCLOSED BUILDING, 2) DOOR HAS 2' OF WIDTH IN BUILDING'S END ZONE, 3 IMPORTANCE FACTOR OF 1.0 4) ANY R F SLOPE, AND 5 SOR SAFETY FACTOR. WIND SPEED MPH 5140 150 150 EXPOSURE LEVEL 8 or C B C MEAN ROOF HEIGHT 30' 30' 25' E141 5/8 SHEET METAL SCREWS AND MARK W. WESTERFlELD, P.E. (4) 1/4`x5/8` SELF TAPPING SCREWS. FLORIDA #48495, NC P.E. J23832, TEXAS P.E. /91513 2` STEEL ROLLER. _ Clopay CLOPAY BUILDING PRODUCTS COMPANY ,LAMB CONFGURATON e5B5 DUKE BLVD. ARATION OF JAMBS BY OTHERS. Building Products MASON, OH 45040 1' n..n.. (513) 770 - 4800 101703 x 12'0'H Florida Building Code Online Page 1 of 4 q, BCIS Home Log In Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL4913 Application Type New Code Version 2004 Application Status Approved Comments Archived Product Manufacturer Clopay Building Products Company Address/Phone/Email 8585 Duke Blvd. Mason, OH 45040 (513)770-6062 mwesterfield@clopay.com Authorized Signature Scott Hamilton shamilton@clopay.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Sectional Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name Gary Pfuehler who developed the Evaluation Report Florida License PE-49850 Quality Assurance Entity Intertek Testing Services NA Inc Validated By John E. Scates, PE Certificate of Independence Referenced Standard and Year (of Standard Year Standard) ANSI/DASMA 108 2002 TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards http://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgtKaHgb3dx8w... 9/17/2007 Florida Building Code Online Page 2 of 4 Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products FBC 1625 FBC 1626 FBC 1714.5.3.1 FBC 1714.5.3.1 Method 1 Option D 07/27/2005 08/11/2005 08/13/2005 08/24/2005 FL # IlModel. Number or Name Description " 4913.1 --]W7-09: 84A, 94, 98, H94, Steel Pan (min. 24 ga.) Single -Car (up to 9'0" 48, 4F, 4RST, H4ST wide) WINDCODE@ W7 Garage Door Limits of Use (See Other) Installation Instructions Approved for use in HVHZ: Verified By: Approved for use outside HVHZ: Evaluation Reports Impact Resistant: PTID 4913 T 4300W8-09-Rev02.pdf Design Pressure: +/- PTID 4913 T 4300W8-16-Rev02.pdf Other: 1) DESIGN PRESSURES +42/-48 PSF 2) PTID 4913 T 4300W8-18-RevOlpdf DESIGN WIND SPEED MAX 145 MPH 3) FOR USE PTID 4913 T 94W7-09-Rev00 pdf INSIDE AND OUTSIDE THE HIGH VELOCITY PTID 4913 T 94W7-16-Rev00.pdf HURRICANE ZONE. PTID 4913 T 94W7-18-Rev04.pdf PTID 4913 T 94W8-09-Rev00.pdf PTID 4913 T 94W8-16-Rev04.pdf PTID 4913 T 94W9-09-Rev04.pdf PTID 4913 T FPA ResiModel Info Rev08.pdf PTID 4913 T Installation Manual Clooay EPS.odf PTID 4913 T Installation Manual Clopav Shiplap Pan.odf PTID 4913 T Installation Supplements WINDCODE(R).pdf 4913.2 W7 16: 84A, 94, 98, H94, Steel Pan (min. 24 ga.) Double Car (9'2" to 16'2" 48, 4F, 4RST, H4ST, 120R wide) WINDCODE® W7 Garage Door Limits of Use (See Other) Installation Instructions Approved for use in HVHZ: Verified By: i Approved for use outside HVHZ: Evaluation Reports Impact Resistant: Design Pressure: +/- Other: 1) DESIGN PRESSURES +42/-48 PSF 2) DESIGN WIND SPEED MAX 145 MPH 3) FOR USE INSIDE AND OUTSIDE THE HIGH VELOCITY HURRICANE ZONE. 4913.3 W7718: 84A, 94, 98, H94, Steel Pan (min. 24 ga.) 16'4" to 18'2" wide 48, 4F, 4RST, HOST WINDCODE® W7 Garage Door _j[ Limits of Use (See Other) Installation Instructions Approved for use in HVHZ: Verified By: Approved for use outside HVHZ: Evaluation Reports Impact Resistant: Design Pressure: +/- Other: 1) DESIGN PRESSURES +42/-46 PSF 2) DESIGN WIND SPEED MAX 145 MPH 3) FOR USE INSIDE AND OUTSIDE THE HIGH VELOCITY HURRICANE ZONE. 13.4 F W8-09: 4400, 4401, HDG, Double -skin Insulated (exterior skin 27 ga. min.;11 http://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgtKaHgb3dx8w... 9/17/2007 Florida Building Code Online Page 3 of 4 HDGL, 4300, 4310, 4301, interior skin 27 ga. min.) Single -Car (up to 9'0" 66, 67, 68, H400, H401, wide) WINDCODE® W8 Garage Door H300, H310, H301 Limits of Use (See Other) Installation Instructions Approved for use in HVHZ: Verified By: Approved for use outside HVHZ: Evaluation Reports Impact Resistant: Design Pressure: +/ Other: 1) DESIGN PRESSURES +48/-60 PSF 2) DESIGN WIND SPEED MAX 145 MPH 3) FOR USE INSIDE AND OUTSIDE THE HIGH VELOCITY HURRICANE ZONE. 4913.5 W8 09: 84A, 94, 98, H94, Steel Pan (min. 24 ga.) Single -Car (up to 9'0" 4RST, H4ST, 120R wide) WINDCODE® W8 Garage Door Limits of Use (See Other) Installation Instructions Approved for use in HVHZ: Verified By: Approved for use outside HVHZ: Evaluation Reports Impact Resistant: Design Pressure: +/- Other: 1) DESIGN PRESSURES +46/-50 PSF 2) DESIGN WIND SPEED MAX 145 MPH 3) FOR USE INSIDE AND OUTSIDE THE HIGH VELOCITY HURRICANE ZONE. 4913.6 W8-16: 4400, 4401, HDG,]Double-skin HDGL, 4300, 4310, 4301, Insulated (exterior skin 27 ga. min.; interior skin 27 ga. min.) Double Car (9'2" to 66, 67, 68, H400, H401, 16'2" wide) WINDCODE® W8 Garage Door H300, H310, H301 Limits of Use (See Other) Installation Instructions Approved for use in HVHZ: Verified By: Approved for use outside HVHZ: Evaluation Reports Impact Resistant: Design Pressure: +/- Other: 1) DESIGN PRESSURES +46.6/-52 PSF 2) DESIGN WIND SPEED MAX 145 MPH 3) FOR USE INSIDE AND OUTSIDE THE HIGH VELOCITY HURRICANE ZONE. 4913.7 W8-16: 84A, 94, 98, H94, Steel Pan (min. 24 ga.) Double Car (9'2" to 16'2" 48, 4F, 4RST, H4ST wide) WINDCODEO W8 Garage Door Limits of Use (See Other) Installation Instructions Approved for use in HVHZ: Verified By: Approved for use outside HVHZ: Evaluation Reports Impact Resistant: Design Pressure: +/- Other: 1) DESIGN PRESSURES +46.6/-52 PSF 2) DESIGN WIND SPEED MAX 145 MPH 3) FOR USE INSIDE AND OUTSIDE THE HIGH VELOCITY HURRICANE ZONE. 4913.8 W8-18: 4400, 4401, HDG, HDGL, 4300, 4310, 4301, Double -skin Insulated (exterior skin 27 ga. min.; interior skin 27 ga. min.) Double Car (16'4" to 66, 67, 68, H400, H401, 18'2" wide) WINDCODE® W8 Garage Door H300, H310, H301 Limits of Use (See Other) Installation Instructions Approved for use in HVHZ: Verified By: Approved for use outside HVHZ: Evaluation Reports Impact Resistant: Design Pressure: +/- Other: 1) DESIGN PRESSURES +46/-50 PSF 2) DESIGN WIND SPEED MAX 145 MPH 3) FOR USE INSIDE AND OUTSIDE THE HIGH VELOCITY HURRICANE ZONE. 4913.9 W9-09: 93, 84A, 94, 98, Steel Pan (min. 24 ga.) Single -Car (up to 9'0" �48 H93, H94, 4F, 4RST, H4ST, wide) WINDCODE® W9 Garage Door http://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgtKaHgb3dx8w... 9/17/2007 Florida Building Code Online Page 4 of 4 Limits of Use (See Other) Installation Instructions Approved for use in HVHZ: Verified By: Approved for use outside HVHZ: Evaluation Reports Impact Resistant: Design Pressure: +/- Other: 1) DESIGN PRESSURES +57/-67 PSF 2) DESIGN WIND SPEED MAX 145 MPH 3) FOR USE INSIDE AND OUTSIDE THE HIGH VELOCITY HURRICANE ZONE. sack Next DCA Administration Department of Community Affairs Florida Building Code Online Codes and Standards 2555 Shumard Oak Boulevard Tallahassee, Florida 32399-2100 (850) 487-1824, Suncom 277-1824, Fax (850) 414-8436 © 2000-2005 The State of Florida. All rights reserved. Copyright and Disclaimer Product Approval Accepts: ® Ha v.rissgRobbA Saturad vER+FYI http://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgtKaHgb3dx8w... 9/17/2007 TABLE 1609.6D ADJUSTMENT FACTOR FOR BUILDING HEIGHT AND EXPOSURE, (l) MEAN ROOF HEIGHT �(leet) EXPOSURE cB >C 'D 15 1.00 1.21 1.47 20 1.00 1.29 1.55 25 1.00 1.35 1.61 30 1.00 1.40 1.66 35 1.05 1.45 1.70 40 1.09 1.49 1.74 45 1.12 1.53 1.78 50 1.16 1.56 1.81 55 1.19 1.59 1.84 60 1.22 1.62 1.87 For sI: 1 foot = 304.8 mm. TABLE 1609.6E GARAGE DOOR WIND LOADS FOR A BUILDING WITH A MEAN ROOF HEIGHT OF 30 FEET LOCATED IN EXPOSURE B (psf) Basic Wind Speed V (mph - 3 second gust) W910 85 so 100 110 120 130 140 150 8 8 10.5 -11.9 11.7 -13.3 14.5 -16.4 17.5 -19.9 20.9 -23.6 24.5 -27.7 28.4 -32.2 32.6 -36.9 10 10 10.1 -11.4 11.4 -12.7 14.0 -15.7 17.0 -19.0 20.2 -22.7 23.7 -26.6 27.5 -30.8 31.6 -35.4 14 14 10.0 -10.7 10.8 -12.0 13.3 -14.8 16.1 -17.9 19.2 -21.4 22.5 -25.1 26.1 -29.1 30.0 -33.4 Roof An le > 10 9 7 11.4 -12.9 12.8 -14.5 15.8 - 77.9 . 19.1 -21.6 1 22.8 -25.8 26.7 -30.21 31.0 -35.1 1 35.6 40.2 16 7 10.9 -12.2 12.3 -13.7 15.2 -16.9 1 18.3 -20.4 1 21.8 -24.3 1 25.6 -28.5 1 29.7 -31.1 34.1 -38.0 For SI: 1 Square foot = 0.929 Sqm, 1 mph = 0.447 m1s, 1 psf = 47.88 N/sqm. 1. For effecctive areas or wind speeds between those given above the load may be interpolated, otherwise use the load associated with the lower effective area. 2. Table values shall be adjusted for height and exposure by multiplying by adjustment coefficients in Table 1606.2D. 3. Plus and minus signs signify pressures acting toward and away from the building surfaces. 4. Negative pressures assume door has 2 feet of width in building's end zone. 1609.6.5.1 Garage doors. Pressures from Table 1609.6E. for wind loading actions on garage doors for buildings designed as enclosed shall be permitted. Property Appraiser - St.Lucie County, FL Page 1 of 1 PROPERTY RECORD CARD Michael R Stuart Record: 1 of 1 <<Prev Next» Spec.Assmnt Taxes Exemptions Permits Home Print Property Identification CIE C �Gy Site Address: 911 BUCKEYE DR ParcellD: 3404-501-0547-010-6 \at Sec/Town/Range: 04 :36S :40E Account #: 39822 y Map ID: 34/04S Land Use: SF Res Zoning: RS-3 City/Cnty: ST. LUCIE COUNTY Ownership and Mailing Legal Description Owner: Michael R Stuart Jennifer Stuart WHITE CITY W 110 FT OF E 600 FT OF S 131.25 FT OF S 1/2 OF Address: 911 Buckeye Dr OUTLOT 7 AND N 1/4 OF OUTLOT 8-LESS N 25 Fort Pierce FL 34982-7215 More... Sales Information Assessment TRIM Total Land and Building Date Price Code Deed Book/Page 2007 TRIM: 127200 Land Value: 58200 Acres: 0.27 8/27/2004 150000 00 WD 2056 / 2353 Assessed: 88050 Building Value: 69000 12/23/1994 100 01 QC 0936 / 2476 Ag.Credit: 0 Finished Area: 1467 SgFt 5/1/1976 36000 00 CV 0252 / 0254 Exempt: 25000 Taxable: 63050 Proposed Tax: 1190.81 BUILDING INFORMATION Exterior Features m • View: RoofCover: SA - Asph Shingle RoofStruct: HP - Hip ExtType: HD+ - HD+ YearBlt: 1976 Frame: Grade: D+ - D+ EffYrBlt: 1977 PrimeWall: BS - CB Stucco StoryHght: 0010 - 1 Story No.Units: 1 SecWall: Interior Features BedRooms: 3 Electric: MX - MAXIMUM PrmintWall: DW - Drywall FullBath: 2 HeatType: FHA - FrcdHotAir AvgHUFI: STD 1/26ath: 0 HeatFuel: ELEC - Electric Prm.Flors: CU - Carpet %A/C: 100 %Heated: 100 %Sprinkled: 0 Special Features and Yard Items Land Information Type Y/S Qty. Units Qual. Cond. YrBlt. No. Land Use Type Measure 3CHT - 3CHT S 1 1 AV AV 1977 1 0100-SF Res 213 -Front Ft 110 3CHT -3CHT S 1 1 AV AV 1977 SDSF - SITE DEV S-F Y 1 1 AV AV 2001 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED, Depth 106.2 http://www.pasle.org/prc.asp?prclid=340450105470106 9/25/2007