Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSOFFICE USE ONLY: Date 26_ 0 7 Fee Due: Receipt# Permit #6 log, b�5 ALL INFO MUST BE COMPLETE. &FILLED INTO BE ACCEPTED St. Lucie County Building and Zo.:ing n 2300 Virginia Avenue �� SCANNED Pierce, FL 34982-5652 BY 772-462-1553 St. Lucie COuntjt APPLICATION FOR ALUMINUM STRUCTURES PERMIT PROJECT INFORMATION 1. LOCATION/SITE ADDRESS: 8912, Champions Way , Port Saint Lu@ie, F 2. S/DNAME:Lakes @ PGA Village SITE PLAN NAME: 3. PROPERTY TAX ID #: 3334-501-0067-000-0 ✓ 4. LEGAL DESCRIPTION (attach extra sheets if necessary): Lakes @ PGA Village Blk A Lot 53 M 5. PLAT 6. PAGE 7. BLOCK 8. LOT BOOK NO. NO. A NO• 53 9. PARCEL SIZE: ACRES/SQ FT. V �' LOT DIMENSIONS 140 -tQ X .84 X 1UQ u4 2 ✓ v 10.. SETBACKS (ACTUAL) FRONT:" BACK: -�p_RIGFIT SIDE:_6 - LEFT SIDE: �9 11. TYPE OF STRUCTURE (CHECK ALL APPROPRIATE BOXES FOR EACH AND EVERY TYPE OF STRUCTURE) TYPE OF CONSTRUCTION N=New A= Addition R = Rebuild SG = Slab on Grade SR = Raised Slab WD = Wo d Deck DIMENSIONS rj SQUARE FEET OF CONSTRUCTION 92 SCREEN ROOM N NE .tom �—%�zwQ-- .�mr..� 40 X 19 760 6 8• ❑ CARPORT/PATIO ROOF ❑ NEW ❑ EXISTING X ❑ HABITABLE GLASS ROOM ❑ NEW ❑ EXISTING X ❑ SUNROOM ❑ NEW ❑ EXISTING X ❑ SHED ❑ NEW ❑ EXISTING X ❑ POOL ENCLOSURE ❑ NEW ❑ EXISTING X ❑ M H ROOF OVER ❑ NEW ❑ EXISTING X ❑ POOLFENCE Linear feet ❑ ROOF SYSTEM OVER EXISTING ACCESSORY STRUCTURE ❑ NEW ❑ EXISTING X OTHER N NEW ❑ EXISTING 1 X 1 66 LN FT TOTAL SQUARE FOOTAGE OF CONSTRUCTION 760 12. VALUE OF CONSTRUCTION• $'p.82+- a 5 I l S The value of construction is used to det ne the a t of perm fees to 6� assessed. St. Lucie County reserves the right to question and/or modify the indicated value of cons ction if it is demonstrated that the submitted figures are not consistent with similar types of construction activities. If the value i $2500 or more, a RECORDED Notice of Commencement must be submitted PRIOR TO FIRST INSPECTION. G GN`� t i-p 2 P lzo V i D J�7_ _0 SLCCDV Form No.: 001-02 Rev. 2119107 d 0 1= OWNER INFORMATION ADDRESS: (8912 Champions Way)?c Gt'O% (SiX CITY: Port Saint Luc0DWaAXJh STATE: FL Ff:�- ZIP l34953 J_nJ!bB_ PHONE (DAYTIME), • (4121 828-3164- email: FILL IN NAME AND ADDRESS BELOW IF THE ,FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE: ? - J� �)o FEE SIMPLE TITLEHOLDER: ADDRESS: CITY: STATE: ZIP PHONE (DAYTIME): ( ) CONTRACTOR INFORMATION STATE OF FLORIDA REG./CERT #: 6-7 63 ST. LUCIE COUNTY CERT #: 4763 BUSINESS NAME: Pioneer Screen Co Inc II QUALIFIER'S NAME: Michael J Newman ADDRESS: 1682 SW Biltmore Street CITY: Port Saint Lucie STATE: FL ZIP 34984 PHONE (DAYTIME): (772) 340-4393 FAXNO.772-340-4626 emai ioneerscreen@msn.com :RCHITECT/ENGINEER: BDQ, Inc 'LDRESS: 1950 NE 170th Avenue. Via' CITY: Williston STATE: FL ZIP 32696 PHONE (DAYTIME): Q52) 529-0080 NOTE: IF APPLICABLE, SUBCONTRACTOR AGREEMENTS MUST BE ATTACHED TO APPLICATION FOR ROOFING, ELECTRIC, PLUMBING, AND HVAC; ZONING REQUIREMENTS' r° Al;r2 h structures will be subject to the requirements of the ST. LUCIE COUNTY LAND DEVELOPMENT CODE. scaled plot plans showing lot size, dimensions of existing host structure, -and proposed aluminum addition. All setbacks including front, side, rear and distance between adjacent property structures in MH Parks shall be indicated on the plot plan.. ❑ 2 sets of color photos for all storm damaged areas to be reconstructed. One picture must include house address number for inspection verification. ( not required for construction unrelated to storms) OFf'ICE USE ONLY' ZONING t Y { SECTION TOWNSHIP RANGE '? E — ` MAP NO.N ZONING V �U V LAND USE R 5 LOT CVG % a Additional Pemuts Yes no t- - REPORT CODE to BIMS FEE MISC FEES TOTAL FEES BUILDING °& ZONING REVIEW. •. REVIEWS ZONING ZONING REVIEWED BY PLANS EXAMINER MISC. I VEGETATION I VALUE OF CONSTRUCTION USING ICC TABLE DATE COMPLETE I I I L I I 4912� INITIALS _ ., _A f PLAN REVIEW SPECIFICATION CHECKLIST PLEASE PROVIDE ONE OF THE FOLLOWING: 2 Sets of Detailed Plans: Dated, Signed & Sealed by an Engineer or Architect holding a Florida State professional license. ❑ 2 Sets of Detailed Plans: Designed in accordance with the AAF Guide To Aluminum Construction in High Wind Areas. (1) ANY PLANS SUBMITTED WITHOUT COMPLYING WITH THE FOLLOWING SHALL BE RETURNED WITHOUT APPROVAL. ALL PLANS MUST BE IN INK AND ANY NOTATIONS IN PENCIL WILL NOT BE CONSIDERED A PART OF A SUBMISSION. • All plans must be legible and must be designed in Architect's Scale on pages which are 81/2" x 11" or larger. • All relevant tables & details, if using the AAF Guide, must be properly highlighted and must match design checklists & drawings. • The plan view must include all dimensions; the location of the host structure and all materials must be sized and identified thereon. • All elevations must be shown, including 4`s wall detail, dimensions and all material must be sized and identified. • All primary and secondary carrier beams, spans, spacing, gauges must be shown [Example: 2" x 8" x .072"]. • All methods of fastening or other details which are relevant to the design must be identified on the Plans. • All upright column heights, sizes, spacing and gauges must be shown as follows: [Example: 3" x 3" x .050"]. • All chair -rails, roof purlins, girts, channels, knee -bracing, k-bracing, cable bracing or any other required component must be sized and identified. • All ridge beams and super gutter or fascia attachments must be identified. • All roof pans or composite panels, with gauges and spans, must be sized and identified. • All footing, slab and ISO pier designs must be on the plans, per the Architect / Engineer's plans & specifications. • All light metal alloys which are utilized shall be designed in conformity with the Florida Building Code of 2.004, Chapter 20, including 2006 revisions. • Barrier railings, if utilized, shall have all materials, fasteners and height specified and shall have self -closing, self- catching gates with picket spacing. (II) SITE CONSTRUCTED SHEDS, HAVING ANY ALUMINUM COMPONENT, SHALL MEET ALL OF THE ABOVE . REQUIREMENTS AND THE FOLLOWING ADDITIONAL ITEMS: (A) 2 copies of the current product approval [i.e. N.O.A. or State of Florida approval] with the proposed "opening" or cladding component. highlighted and with fasteners and design pressures, per FBC 1714, clearly identified. (B) 2 electric schematics; in accordance with the N.E.C.,.if applicable. (C) Design pressures, per Table R 30i.2-(2), identified on the openings of all Plans. (III) HABITABLE ROOMS/ADDITI'ONS-DESIGNS'SHALL MEET ALL OF THE ABOVE REQUIREMENTS, EXCEPT AAMA SPECIFICATIONS, AND CHAPTER 13 OF THE FLORIDA BUILDING CODE. (IV) SUNROOMS (as defined in R202 or FBC1202.1) MAY BE CONSTRUCTED; SO LONG AS THEY MEET ALL OF THE ABOVE REQUIREMENTS AND MUST BE IN STRICT COMPLIANCE WITH AAMA/NPEA/NSA2100.02 AND MEET THE FOLLOWING ADDITIONAL ITEMS: (1) The designer or engineer will state on all Plans, which Category of Design [3.1.2] will be used, inclusive of the definition. (2) If designing a Category 4 or Category 5 structure, as defined in the current Edition of 3.1.2.4 and 3.1.2.5, proper energy calculations and long form equipment sizing calculations shall be required, pursuant to Chapter 13 of the current State of Florida Building Code. (V) MOBILE HOMES (FAC 15C-2.0081 - FAC 15C-2.0072): ALL STRUCTURES ADJACENT TO OR NEW ROOF SYSTEMS (Pan or Composite) OVER EXISTING ADJACENT STRUCTURES TO A MOBILE HOME SHALL REQUIRE: (a) A 4`s wall or a current, signed original manufacturer's attachment approval letter which includes the model number, serial number and current owner's name and street address. (b) That the complete guide to H.U.D. specifications be strictly adhered to. (c) A Certified Florida Engineer may design the manner of attachment of the proposed structure to the host house but shall assume full responsibility for both structures' integrity by site specific documentation. CERTIFICATION: This application is hereby made in order to obtain a permit to do the work and installations as indicated, and to obtain a certificate of capacity, if applicable, for the permitted work. NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU.: PAYING TWICE FOR RVIPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE TO APPLICANT: IN THE EVENT IT IS NOT YOUR RIGHT TITLE OR INTEREST THAT IS SUBJECT TO ATTACHMENT, THE APPLICANT DOES HEREBY MAKE A GOOD FAITH PROMISE TO DELIVER A COPY OF THE ATTACHED CONSTRUCTION LIEN LAW NOTICE TO THE PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT, AND DOES SO AS A CONDITION PRECEDENT TO THIS PERMIT 1. If utilizing the AAF Guide to Aluminum Construction in High Wind Zones, I the Contractor/Owner Builder hereby certify that the components being used, fasteners type and fastening pattern meet all the requirements for the designated wind zones established by the county and take full responsibility for complying with the submitted design of the structure being permitted. 2. I further certify :that all the foregoing information is accurate, that no work or installation has commenced prior to the issuance of a permit and that all work shall be performed in compliance with all applicable laws regulating construction and zoning in this jurisdiction: I und6rstand ihat"separate permits may be required for ELECTRICAL, and HVAC, etc., not otherwise included with this building permit application. 3. I , the Contractor / Owner Builder, have verified that the existing foundation meets the requirements of the Engineer of Record and is in adequate condition to withstand the uplift and weight of the aluminum structure and said structure will not exceed the fo rint of a structure that was in existence prior to removal by the storms. OWDffCONTACTOR SIGNATURE t. STATE OF FLORIDA COUNTY OF` A-. VXAC . The foregoing instrument was acknowledged before me thisQ day of tf _, 20gD by - �..� Oklo ,._.._, ESQ Iio is personally known to me or who has produced Cr Ss art. A as' entification. Signature of Notary Apo Kevin J Stewart (SEAL) d� My Commission DD354413 w Expires October 29, 2008 IMPORTANT NOTICES: SIGNATURE STATE OF FLORIDA COUNTY OF Sk . � The foregoing instrument was acknowledged before me this50 day of0a`l by �Ald rno I mo+—inn who is personally known to me or who has produced .c-. as identification. Signature of Notary Kevin J S4ewrart (SEAL) e9 y� ,g My Commission DD354413 Sao, �cl? Expires October 29, 2008 • TWO (2) SIGNATURES ARE REQUIRED. EACH SIGNATURE MUST BE NOTARIZED. IF APPLYING FOR THIS BUILDING PERMIT AS AN OWNERIBUILDER, THE OWNER MUST PERSONALLY APPEAR TO SIGN THIS APPLICATION IN THE OFFICE LISTED ON THE FRONT OF THE APPLICATION. • ALL SIGNATURES ON APPLICATION SUBMITTED SHALL BE ORIGINAL. COPIES, FAXES, OR STAMPED REPRODUCTIONS ARE PROHIBITED. • WHEN A PERMIT IS AVAILIBLE FOR ISSUANCE BUT IS NOT PICKED UP WITHIN THIRTY (30) DAYS AFTER NOTIFICATION OF AVAILIBILITY, IT WILL BE VOIDED. IF THE APPLICATION IS RESUBMITTED, AN ADDITIONAL FEE WILL BE CHARGED. 41 Code Compliance Division Ft Pierce, IL 349 2 INSPECTION CARD Ft Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1148 http://stl ucieco.gov/ce Permit #: SLC- 0709-0325 Conf #: 661 Type: Building (Miscellaneous) Issued 10/16/2007 Status: FIN Double Fee: No Job Location 8912 CHAMPIONS WAY City: PORT ST LUCIE Jurisdiction: St. Lucie County Lot: Block: Parcel: 3334-501-0067-000/0 - Subdiv: LAKES AT PGA VILLAGE Flood: Elev: Flood Map: Job Description: NEW CONSTRUCTION OF 36.75 X 19 SCREEN ROOM ON NEW PERIMETER FOOTING. Setbacks Left; 10.00 Right 6.00 Inspection Notes: Front Rear: 30.00 Contractor NEWMAN MICHAEL J PIONEER SCREEN COMPANY INC II (772) 340-4393 1682 SW BILTMORE ST PORT ST LUCIE, FL 34984 Property Owner JERRY FERRONE (412) 828-3164 8912 CHAMPIONS WAY PORT ST. LUCIE, FL 34953 Property Owner KAREN FERRONE (412) 828-3164 8912 CHAMPIONS WAY PORT ST. LUCIE, FL 34953 Permit # Status PT Cert # SUB -PERMITS DBA Owner / Builder Job Description INSPECTIONS - For Requests, Call: (772) 462-1261 Permit # Code Description Priority Date Sched. Res Description Inspector Date Insp. 0709-032E 110 Footer/Foundation 1 10/19/2007 90 Approved Shaun Milligan 10/19/2007 10/18/07 incall schedule with jody/ contr. bac 0709-032E 121 Termite Spray 1 10/19/2007 90 Approved Shaun Milligan 10/19/2007 0709-032E 904 Fastners 2 12/03/2007 90 Approved Shaun Milligan 12/03/2007 0709-032E 999 Final Inspection 2 12/03/2007 99 Final Approval Shaun Milligan 12/03/2007 null Scheduled: Fri Nov 30 14:29:04 EST 2007 with value: Mon Dec 3 00:00:00 EST 2007 Permit Nun 0709-0325 r3 4 St tulle County Inspections. 2300 Virginia Avenue ri t-Pierce, FL 34982 ('772) 462-2172 . CERTII+ICAT.IE OF T]ERMIT1E TREAT) EN'T CONSTRUCTION SOIL TREATMLt NT PKkA l BUILD PEST {:ONTRUL CO NTRACTUR 1856 SW Bayshora 131 yd Pori~ St Lucie, FL 34984 PEST CONTROL LICENSE It We, the undersigned, hereby certify that we have pretreated the above -described construction for subterranean termites in accordance with the standards of the National a Control Association. Square feet of area treated: ® Chemicals used:. / Pereentage of solution: z Date of trea ent: sooting ❑ Tst TretiMient ❑ Ro-treat ❑ S lab ❑ lsl Treatment ❑ P.e-treat -, ❑ Driveway ❑ 1st Tretthndnt ❑ Re-it'ettt ❑ Pools ❑ 1st Treatment ❑ Re -treat Total gallons used: Time of Treatment:_, FRC104.2.6 Cerl(fleateofProtecllveTrealtnenlforprepenllottafaer�iiiles. A weather reslslanl jobsile posting board shall be provided to receive duplicate Treatment Certificaies as each regtlitell prorective treaunent is completed, providing a copy for the person the permit Is issued to and another copy for the bttildlug permit fles, The Treatment Cerdjicale shall provide the pro(hict used, idenlity'of the applicator, time mil date of the treatment, site loc'atia)1, area treated, ehemicdl used, percent concenUation and number of gallons used, to etlablish a verifiable record of protecllve tre,ohnent. , If the soil chemical bart•ler method for termite prevettilon lr used, final exterior trealment shall be completed prior io final building approval. St Lucie County requires for the final inspection for CO, a Perinanent Sticker to be placed on the electrical panel box cover, listing all the treatments and, dates of appliea't➢ons. , ❑ Other �❑ 1st Treatment ❑ Re -treat ❑ Perimeter -for Final Inspection NOTE: There must be a completed forin for each required treatment or re -treatment mid.this form must be oil Me job site to be picked up by the inspector at time of each hispectiolz or the Scheduled hisImctiou vill fail and a re-inspe.etion fee charzed. . BILLING INFORMATION I� INSTALLATION INFORMATION �r.wr""fliwWfAw FINANCE COMPANY (IF APPLICABLE) NAME OF PARTIES Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772)462-1553 Fax: (772)462-2522 http://stiucieco.gov/ce Date: 26 September 2007 Job Address: 8912 CIIAMPIONS WAY Received By: spellsv Paid With: CK Paid By: PIONEER SCREEN CO,. Building Receipt Sign: Receipt#: 0000057678 ermit Number: SLC- 0709-0325 - Amount: $50.00 .redit Card Number: Check Number: 47895 -�t �117-4 Building Code Compliance Division Receipt 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 http://stiucleco.gov/ce Date: 16 October 2007 Receipt #: 0000058197 Job Address: 8912 CHAMPIONS WAY 'ermit Number: SLC- 0709-0325 Received By: goycochb Amount: $130.00 Paid With: ck i . edit Card Number: 'tC-hbck Number: 47981 Paid By: pioneer screen Sign: •09/14/2007 14:40 7723404626 AF-32R itECr7 WG-RETURN TO! PIONEER SCREEN CO II PAGE Si %i304N M. FPY. _r_. rLERV OF THE CIFC WT CG0te„ SAIMT LUCF Cl)UNT1 lei_ OT�CE O F COBOR CQ 1ONT The undersigned hereby given -,notice that improvement wil 1 be made to certain real proper, and is accordance with Chapter 113, FlbnidA vtnmtes the following itfomation i s provided in the Notice of eotntriencemeot 1. DESCRIPTION OF PROPERTY (I FA description of d street address) TAX ML11D NUMRER��U $pl t�0i• OOU 0 SU8D1V1SIt)1Y BLat:IC TiIACT LOT,�31aLDG UNIT- ---- 2.(;liNERALDESCRIPTIONOF'xnIIRRO%'1EhIE§r:Install Screen / Pool _Bnclosure 3, OWNER INFORMATION: aNamee-Xr - b. Addross�l `,�Cit'�at��A�4 �b �e ���5�-.�„ lf��•t iZ c. inteaeat in properry� d. Name and address of fee simple titleholder (if other th to owner) r4, CONTRACTOR'S NAME, ADDRESS AND PHONE NUM1 EM Pioneer Screen Co Znc II 1682..5W.-Biltmore Stre.er- Port Saint: Lucie, FL 34984 . (772) 340-4393 5. SURETY'S NAME, ADDRESS AND PHONE NUME Eli AND BOND AMOUNT: 6. LENDER'S NAME, ADDRESS AM PHONE' "MlI ER: 7, Persons within tho State of riorida designated by Owner upon whom notices or other documents may bt setvtd as provided by Section 7.13.13 (1)(a) 7., Florida Statutes: NAME, ADDRESS AND PHONE NLWISR: S. In addition to himself or hcrsol& Owner desipates the fc Ilowing to receive a copy of the Lienor's Notice ae provided in Section 713..13 (1)Cb), Florida Statutes: NAME, ADDRESS AND PHONE NUVi HER: 9. Expirntion date of tsotice of commencement (the expinti. In date is 1 year from the date of recording unless a diZerent date is specified) 20 gniture of Owner or Print Nam and Provide Signatory's-Title/Office Owner's Authorized 0ficelADlrectorJPariner1Msnager State ofMorld® County off A chjL , The;forcgoing instrument wes'rlckriowledged,before me thi s day o=y✓`.C' 120 (Name of perre) (Type of sutharity...e.g. Oumer, officer, trustee, attorney in fact) For - (Name of party on, behalf of whom instrument woaislwfT?: +. t K"Jftoaft • My CommiWon DD354413 (Py cued Name of Notary Public) (sr mu a of Notary Public) Ear elk empires �� 2g, � Under pomaltios of perjury, I dcolom that 1 have read the 'ongoing and that tho facts in it are true to the best of my knowledge and belief (section92525; Florida statutes); snansiture(s).of.O.w.ner s) or. •ner($ A4t torivid 011lcerMrectorMartner/Msnager who sload above-, toll `,, t _ %z 7 t !' S p F i `a r1d�.% n° I 'r7•[� J`a'�% /-"' R ff,: �' -v Y �t�,./"WG•"JL.. i• r. ai• .:F' rs f. s:�' , ,s(gl�@ttrre .ti zF yi7� t �F..'.1. �.' ". ��Q' `-.s.ia Z�r t �.Lt�/`-',l,ri �pr7L'tCi�=�i{XStle)E_� y ,� Ss:. � r i/,-_ pM KAREN FERRONE 412 828 3164 P. 02 ir c7p g rl &=12030126"' ti R-295,00' L-154.40' LOT 54 W.- LOT 52 . . ............... -)UNDA i"Egr "Itpry MAI n115 M(NDA4), "Wr A t�A MK AND COWpT nvp f OMM 4W A 'of RX po' I WT$ArJW0riWrVlpW -A -lt> U'o n 6EC Vl 5CAL (OYV A 'W PA Mw 614 w CI de y McNeal Mrs ���7,, rt ?Lr­ a Ml"'WAL PROfTSPONAL RAMYOR 4110 MAPPER 12,ffdj MIN. SETBACK REQ. FRONT Ro r 311DESES C1413 �I'Epts-3j REAR I ZNG, '6 -, 14 '112'0 L= 36.42 PAGE Z OF 2 PAW SERVING M05T FLORIUA COUNTIES TARGET S URVE YING, I W. LD 6,Z5 51JI1E 210 SIATYWIOF UUMPERS MT PALM BEACH, FL 33407 PHONE fV00) 274 -4007 PHOIC (501) 1140-4800 (800) 741-0576 rAUSIMILL AUG—,30-2007 01:09 PM KOREN FERRONE 412 82$ 3164 i f V*, 44, R-295,00' L=154.40' L." L QT 54 11 LOT 52 VIE Y B U N D A R Y c 1,J I I I r r"fo.s I r swwr 4 A TR r $MTA?t*v OF A VEY MY wrenw, r AUNOWA)TV RferRem; 111�o A A7 ,4 "gM 59T&r Clyde McNeal rt, YLf' o mwrZ Pporrys,WAt 'SORWYOR ANO V,4PFfR J208J MIN, SEMACK REQ. .FRONT�g SIDES 51 E�: r� ZNQQ 0 kp ' R 14*12'0 R= 155,0( L=X42 ti PAGE 2 OF 2 PAGES SERVING M05T FLORIUA COUNTIES JARGET SURVEYING, INC. LB #6135 $501 CORPORAlt WAY SWITE 219 VATEMOr Misr DERS WE$T FAIN BEACH. PL 34407 plioNt (m) 226-4no PADNE (561) 640-4800 rACSIMiLt (800) 741-0576 �`� � C'm�/cre�e t��ers' �N �. #..�RebdrS COW. od KL -S l�' R�N�%�qj�.ru- .DESIGN NOTES: I. ALL DIAGONAL BRACING SHOWN IN BOTH THE ROOF AND WALLS SHALL BE 2 x 2 x .093 TUBE MATERIAL. 2. IS x 14 MESH SCREEN IS THE MAXIMUM ALLOWABLE DENSITY FOR THIS ENCLOSURE'S DESIGN. 3. DOOR(S) MAY BE PLACED INTO ANY SCREEN WALL PANEL EXCEPT FOR THOSE THAT CONTAIN DIAGONAL BRAGING. a OVERALL DESIGN COMPLIES WITH THE 200(o AMENDMENTS TO THE F.B.C. 2004 BUILDING CODE, FOR 140 MPH WIND LOAD (3-SECOND GUST), FOR EXPOSURE CATEGORY "15 TH15 5YM50L REPRESENTS DIA60NAL 0 T1415 SYMBOL REPRESENTS 0 WIND BRACING (IN BOTH THE RODE BEAM SPLICE LOCATIONS AND WALLS), 2 x 2 x .093 TUBE MATL. SITE-SPECIPIC NOTE: �( THIS JOB IS BEING INSTALLED OVER o A BRICK PAVER DECK, AND SHALL x HAVE A 12 - INCH x 12 - INCH ISOLATED X FOOTER, WITH TWO (2) #5�, CONT. ON ALL THREE SIDES OF THE ENCLOSURE. EXISTING HOST STRUCTURE OVERA" WIDTH 6' (o' Ix2 X x (TYP) x X N Cv N N 2 x 3 x .010 PIONEER SCREEN Co., 11 SCREEN ROOF ENCLOSURE FOR: X�gu) C1, j OL ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR COMPLIANCE REVIEWED BY 4" DATE -U/D-41) -07 PLANS AND PERMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE. 0-7 Oq - o3a S THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE COAEB, ® M �coU co z 0 0, �- 0 NJ 9 0 0 inn co) W 0: -6-0,9 no Q UJ �,. �0 0 LL W % d z=w a moo U)a F,45RICATION / INFALL.ATION REQUlREp GUIDELINES: NOTE: ANY J056 THAT REQUIRE SITE -SPECIFIC DESIGN / ENGINEERING MUST BE -SUBMITTED TO THE ENGINEER OF RECORD FOR SUCH DESIGN CONSIDERATION PRIOR TO THE JOB BEING PERMITTED, FABRICATED OR INSTALLED. LEAD-TIMES FOR SUCH WORK WILL DEPEND ON OUR CURRENT WORK LOAD AT ANY GIVEN TIME. THE ITEMS BELOW ARE NOT PERMITTED ON ANY ENCLOSURE WITHOUT SITE -SPECIFIC DESIGN 4 AUTHORIZATION FROM THE ENGINEER OF RECORD. I. NO SCREEN ROOF BEAMS SHALL BE LOCATED WITHIN 12-INCHES OF ANY OUTSIDE CORNER OF ANY WALL, FASCIA OR STRUCTURAL GUTTER. 2. NO CABLE BRACING SHALL BE USED ON ANY ENCLOSURE AT ANY TIME FOR THE RESISTANCE OF ANY IMPOSED DESIGN LOADING. 3. THERE SHALL BE NO SUBSTITUTION OF EITHER CONCRETE ANCHOR TYPE OR MANUFACTURER OTHER THAN THOSE SPECIFIED ON THESE ENGINEERED DESIGN DRAWINGS. 4, THERE SHALL BE NO SCREENING UTILIZED THAT IS FINER THAN 18 xJ4 MESH SCREEN WITHOUT SITE -SPECIFIC DESIGN (THAT SHALL BE DONE PRIOR TO THE JOB BEING FABRICATED OR INSTALLED) WITH JOB DRAWINGS BEARING THE ENGINEER OF RECORDS ORIGINAL SIGNATURE (IN BLUE INK) UNDER HIS EMBOSSED SEAL. 5. ALL SCREEN ROOF ENCLOSURES MUST BE POSITIONED ON THE EDGES OF THE CONCRETE DECK 50 THAT THE OUTER SURFACE OF THE SCREEN FRAME IS NO LESS THAT 2 3/4 - INCHES IN FROM THE EDGE, TO CREATE PROPER EDGE: DISTANCE FOR THE SPECIFIED CONCRETE ANCHORS AT THE BASE OF EACH COLUMN. 6. ALL ROOF pURLINS IN THE ROOF AND CHAIR RAILS IN THE WALLS SHALL NOT EXCEED 8-FEET CENTER - TO - CENTER SPACING (SEE APPROPRIATE DETAILS ON OTHER SHEETS OF THIS DRAWING FOR SPECIFIED MATERIAL SIZES REQUIRED FOR ANY GIVEN APPLICATION. 1. NO SCREEN ROOF ENCLOSURE SHALL BE INSTALLED UTILIZING SEvEN-INCH STRUCTURAL GUTTER, AS IT IS NOT PERMITTED, OR STRUCTURALLY ADEQUATE UNDER THIS ENGINEERING. THE ITEMS BELOW MUST BE 51JBMITTED TO THE ENGINEER OF RECORD PRIOR TO MEASURING 4 LAYOUT, FABRICATION OR INSTALLATION FOR THE REQUIRED SITE -SPECIFIC DESIGN. I. ANY SCREEN ROOF ENCLOSURE THAT UTILIZES ROOF BEAMS THAT EXCEED 40-FEET IN SPAN, AT ANY POINT ON THE ENCLOSURE. 2. ANY SCREEN ROOF ENCLOSURE THAT UTILIZES WALL COLUMNS (UPRIGHTS) THAT EXCEED 12-FEET IN HEIGHT AT ANY POINT ON THE ENCLOSURE. 3. ANY ENCLOSURE THAT UTILIZES ANY CARRIER BEAM (A BEAM THAT ACTS AS SUPPORT FOR ANY OTHER SCREEN ROOF BEAM) AT ANY PDINT ON THE ENCLOL5URE. NO CARRIER BEAM SHALL BE PERMITTED TO BE MOUNTED TO THE FASCIA OF ANY HOST STRUCTURE (AS PRIMARY SUPPORT). 4. INSTALLATION OF ANY SCREEN ROOF ENCLOSURE ON AN EXISTING HOUSE FASCIA WHERE THE OVERHANG EXCEEDS 2-FEET. NOTE THAT IF THE EXISTING RESIDENCE WAS CONSTRUCTED UNDER ANY BUILDING CODE PRIOR TO F.B.C. 2001, THE JOB MAY REQUIRE FOURTH -WALL TYPE CONST, AS THERE IS NO WAY TO CERTIFY THE ABILITY OF A HOST STRUCTURE THAT WAS ONLY BUILT TO WITH- STAND IIG MPH WIND LOADS OR LESS, (AS WAS REQUIRED UNDER PREVIOUS BUILDING CODES) TO RESIST THE IMPOSED LOADS OF AN ENCLOSURE THAT 15 DESIGNED TO WITHSTAND THE LOADS IMPOSED UNDER THE 140 MPH WIND LOAD SPECIFIED IN THE CURRENT BUILDING CODE. MINIMUM FOOTED T45LES AX. BM. OOPPEOTER PAN 8 ° WITH (IJ "54 T TO 38' 8' X_UOM CONT. UP I' 10'x12'WITH (1) K54 CONT. UP TO 40' U' x 12" WITH �GENT UP TO 55' ISOLATED MAX. BM. FOOTER(-) SPAN 12'x12'WIT4 (2) SO CONT, UP TO 30' 12' x 16' WITH (2) SO CONT. 31' TO 39' 14' x 16' WITH (2) SO CONT. 40' TO 44' 16' x I6' WITH 44' TO 52' (2) ISO CONT. IF A JOB EXCEEDS THESE PARAMETERS, THE FOUNDATION MUST RE SITE-5pECIFICALLY DESIGNED BY THE ENGINEER MONOLITHIC FTG. LOAD CAPACITIES ARE BASED ON A MIN, OF 3 FEET OF CONT. CONCRETE, 2,500 PSI MINIMUM, W/ WIRE OR FIBI=RMESH REINFORCEMENT ()ISOLATED FOOTERS MAY BE USED ON EDGE OF EXIST. CONC. SLAB OR UNDERNEATH THE PERIMETER OF BRICK PAVER DECK (ALL SIDES) THE ENGINEER OF RECORD WILL NOT BE ABLE TO CERTIFY THE STRUCTURAL INTEGRITY OF ANY EXISTING CONCRETE DECK / FOOTINGS THAT WERE INSTALLED WITHOUT PERMITS, AS THERE WOULD BE NO RECORDS TO VERIFY CONCRETE THICKNESS', FOOTER SIZES AND THE SIZE AND QUANTITY OF STEEL RE -BARS THAT WOULD BE REQUIRED UNDER THE CURRENT BUILDING CODE STANDARDS. SCREW SPACING AND EDGE DISTANCE SPEC.'S THIS TABLE IS BASED ON THE PROPERTIES OF C-1022 LOW CARBON STEEL SMS AND SELF -DRILLING (TICK) SCREWS, WHICH ARE AN INDUSTRY STANDARD SCREW. SCREW SIZE NOMINAL SCREW DIAMETER (IN.) MIN, EDGE DISTANCE MIN. CENTER -TO - CENTER DISTANCE 08 #10 0,188 3/8' 1/2' 012 0.219 1/2' 5/8, 014 0.250 5/8' 3/4' SNAP / LAP JOINT INTERNAL CONNECTION SPECIFICATION (UTILIZING SCREW 5065E5) ALL INTERNAL CONNECTIONS UTILIZING THE EXTRUDED SCREW BOSSES SHALL HAVE: CONNECTION NOTE: 010 SMS SCREWS, WITH A MINIMUM EMBEDMENT INTO THE SCREW 6055 OF 1 3/4" (UNLESS A SSSN I ALL FRAMING MEMBERS ON ANY OTHERWISE SPECIFIED ON ANY CONNECTION DETAIL). LL SCREW PO E I A G VEN ENCLOSURE THAT UTILIZE SNAP EXTRUSION MUST BE FILLED (EXAMPLE: THE 2 x 3 x .010 CHAIR RAIL / ROOF PURLIN OR LAP JOINT IN THEM SHALL _ _,_j� {AT HAS SIX SCREW BOSSES, MUST HAVE SIX OF THESE 010 5M6 SCREWS INSTALLED HAVE 012 TEKS INSTALLED THRU AT EACH END OF THAT COMPONENT, AT EACH CONNECTION). THE SNAP OR LAP CONNECTION AT IS INCHES ON CNTR. (TYP), THESE TEK SCREWS ARE TO E3E PLACED ON BOTH EDGES OF SCREEN PANEL INSTALLATION SPECIFICATION., THE UPRIGHT (BOTH THE INNER PLEASE NOTE THAT ALL SCREEN PANEL OPENINGS (BOTH ROOF AND AND THE OUTER EDGE) IN ALL WALLS) SHALL BE INSTALLED ON ALL FOUR SIDES WITH SPLINE (INDEP- CASES. THIS SPECIFICATION ENDANT OF ALL SURROUNDING PANELS). THE ONLY FRAMING COMPONENTS APPLIES TO UPRIGHTS AND THAT ARE NOT REQUIRED TO HAVE SPLINE INSTALLED IN THEM ARE ALL OF BEAMS BOTH. THE DIAGONAL WALL AND ROOF BRACING. SIGN DISCLAIM ALL CONCRETE ANCHOR5 SPECIFIED ON THIS DETAIL SHEET ARE MANUFACTURED BY 'RED HEAD' ANCHORING SYSTEMS, AS ALL LOAD CAPABILITIES ARE BASED ON TEST DATA FURNISHED BY RED HEAD IN THEIR PRODUCT AND RESOURCE BOOK. NO SUBSTITUTIONS OF ANY OTHER MANUFACTURER'S CONCRETE ANCHOR5 15 PERMITTED WITHOUT SUBMITTAL OF THE COMPANY'S TEST DATA (TO VERIFY EQUIVALENT LOAD CAPACITIES) AND A WRITTEN, SIGNED AND SEALED LETTER OF AUTHORIZATION FROM THE ENGINEER OF RECORD. ANY UNAUTHORIZED ANCHOR SUBSTITUTION SHALL BE DEEMED NON -COMPLIANT WITH- TH15 DESIGN. THE ANCHORS TO BE USED FOR APPLICATIONS SPECIFIED IN THIS ENGINEERING DESIGN PLAN ARE AS FOLLOWS: 1/4' DIA FASTENERS:. RED HEAD ITW TAPCON (SEE INDIVIDUAL DETAILS FOR MINIMUM EMBEDMENT DEPTH INTO CONCRETE) 3/8' DIA. FASTENERS: 3/8° TRU BOLT WEDGE ANCHOR (SEE INDIVIDUAL DETAILS FOR QUANTITY OF FASTENERS NEEDED) (MINIMUM EMBEDMENT 5HALL BE 3' INTO CONCRETE UNLESS OTHERWISE SPECIFIED IN ANY DETAIL) 3/8' LARGE DIAMETER TAPCON (LDT) (BEE INDIVIDUAL DETAILS FOR QUANTITY OF FASTENERS NEEDED) (MINIMUM EMBEDMENT SHALL BE 21i2' INTO CONCRETE UNLESS OTHERWISE SPECIFIED IN ANY DETAIL) FOR BRICK PAVER INSTALLATION: FOR INSTALLATION ON A BRICK PAVER DECK, THE ONLY FASTENERS THAT WILL MEET THE DESIGN CRITERIA INDICATED WITHIN THESE DESIGN SPEC.'S ARE THE RED HEAD TRU BOLT WEDGE ANCHOR (3/8' x I'), WHICH BASED ON 1/8' ANGLE, I x 2 O.B., 211$' THICK BRICK PAVER AND A MAXIMUM MORTAR BED THICKNESS OF 3/4'. THIS SCENARIO WILL STILL MEET THE MINIMUM FASTENER EMBEDMENT. IF ANY OF THESE CONTRIBUTING FACTORS EXCEED THE DIMENSIONAL BREAKDOWN INDICATED, THE JOB MUST BE PRESENTED TO THE ENGINEER OF RECORD FOR SITE -SPECIFIC ANCHORING DESIGN. EXIST. HOUSE FASCIA NOTES: IT SHALL BE THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO IN5PECT AND INSURE THE CONDITION OF THE EXISTING FASCIA, TO DETERMINE IF IT 15 IN GOOD ENOUGH CONDITION TO SUPPORT THE PROPOSED SCREEN ENCLOSURE (PRIOR TO ITS INSTALLATION) THERE IS NO CERTIFICATION, EITHER EXPRESSE�OR IF1PLIkD lR THfS ERiSlNEERIKG-DESTGN-D-CCUMENT- REGARDING THE ABILITY OF ANY HOST STRUCTURE TO RE515T THE BUILDING CODE SPECIFIED DESIGN LOADS IMPOSED BY ANY PROPOSED SCREEN ENCLOSURE. SUCH CERTIFICATION WILL BE DEPENDENT ON AVAILABILITY OF ORIGINAL DESIGN AND CONSTRUCTION DOCUMENTS, AS WELL AS ORIGINAL PERMIT AND INSPECTION RECORDS FOR THE H05T STRUCTURE. CERTIFICATION OF THE HOST STRUCTURE, IF IT IS . REQUIRED, WILL ULTIMATELY BE POSSIBLE ONLY IF THESE RECORDS CONTAIN ALL THE INFORMATION NEEDED BY THE ENGINEER TO PERFORM ALL OF THE NECESSARY ANALYSIS TO DETERMINE IF SUCH CERTIFICATION 15 EVEN POSSIBLE. b> t= io ®®z 9�� c+� U. 00 8wLul 8 acn~ aaw �®.Zcz oo ljL LUZ®-® �a� �- Lu � co LM 0cn o >�S3 Z !ggRa � LL; cN GENERAL NOTE5 AND IDE51GN PARAMETER& I. THE OVERALL DESIGN COMPLIES WITH THE 200(o AMENDMENT TO THE FLORIDA BUILDING CODE 2004 (CHAPTER • 16 AND 20), AND 15 BASED ON THE FOLLOWING PARAMETER5: A. WIND SPEED: 140 M.P.N., 3-SECOND GUST B. EXPOSURE CATEGORY 'B' C. DESIGN PRESSURES AS FOLLOWS: a) SIMULTANEOUS WIND LOADING 0 (b F.S.F. FOR SCREEN ROOF AND 21 P.5F. FOR SCREEN WALLS b) 300 LB LOAD APPLIED VERTICALLY DOWNWARD ALONG ANY ONE FOOT (it -INCHES) OF ANY PRIMARY MEMBER (EXCLUDING DIAGONAL WIND BRACING, WHICH 15 TREATED AS A 'STRUCTURAL MEMBER' UNDER 2006 AMENDMENT DEFINITIONS. D. MAXIMUM ENCLOSURE HEIGHT SHALL NOT EXCEED 30-FEET E. ALLOWABLE DEFLECTION OF 'L / 60% A5 SPECIFIED I TABLE p1610.1, FOR NON -HIGH VELOCITY HURRICANE ZONES. F. CONTINUOUS LOAD PATH IS PROVIDED, 2. MATERIALS (UNLESS OTHERWISE SPECIFIED BY THE ENGINEER OF RECORD): A. ALL EXTRUSIONS SHALL BE ALUMINUM ALLOY 06063-T6 (NOTE THAT THE 5PLICE PLATE MATERIAL MAY BE EXTRUDED FROM ALLOY 06061-T(o, 1F THIS MATERIAL 15 MORE READILY AVAILABLE TO THE CONTRACTOR) (SEE COMPONENT SHAPES AND SIZES AT RIGHT). B. FASTENERS SHALL BE ALUMINUM ALLOYS 2024-T4 t 1015-T(o, DOUBLE CAD -PLATED STEEL, HOT -DIPPED GALVANIZED STEEL, OR 300-6ERIES STAINLESS STEEL. IT 15 THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE THE APPROPRIATE MEANS FOR SEPARATION OF DISSIMILAR MATERIALS AS THEY ARE DEFINED IN SECTION �2003.8.4. THE CONTRACTOR MAY IMPLEMENT ANY OF THE MEANS SPECIFIED IN THIS SECTION. ANY ALTERNATIVE MEANS MUST BE ACCOMPANIED BY A LETTER of CERTIFICATION FROM THE PRODUCT'S MANUFACTURER (THIS LETTER MUST BE SIGNED AND SEALED BY A FLORIDA LICENSED STRUCTURAL ENGINEER), WHICH STATES THAT THEIR PRODUCT MEETS / EXCEEDS ALL OF THE REQUIREMENTS SPECIFIED IN THE ABOVE - LISTED SECTION. THI5 LETTER SHALL ALSO BE REVIEWED AND APPROVED BY THE ENGINEER OF RECORD FROM B.D.Q., INC. C. SCREEN CLOTH SHALL BE VINYL COATED, WOVEN FIBERGLASS, MAXIMUM DENSITY OF 18 x 14 158% OPEN). 3. ALL FASTENERS THAT PASS THROUGH ANY EXTRUSION INTO CONCRETE, MASONRY, WOOD, STEEL, ALUMINUM OR ANOTHER EXTRU51ON SHALL HAVE A 5/6-INCH DIAMETER WASHER, MINIMUM (UNLESS OTHERWISE SPECIFIED BY THE ENGINEER OF RECORD), AND SHALL BE NO MORE THAN 18-INCHES CENTER - TO - CENTER SPACING. 4. ALL FASTENERS ADJACENT TO UPRIGHTS THAT DO NOT REQUIRE REINFORCING ANGLE CLIPS, SHALL BE PLACED WITHIN TWO (2) INCHES OF THAT UPRIGHT (TYP. FOR BOTH SIDES). 5. SCREEN DOOR(5) MAY BE LOCATED IN ANY SCREEN WALL PANEL, EXCEPT FOR THOSE THAT CONTAIN DIAGONAL 'Wf",D BRACINa ('K-BRACING'). ALL DOCKS SHALL BE SELF -CLOSING AND SELF -LATCHING. DOORS INSTALLED IN AN ENCLOSURE THAT SURROUNDS A POOL / SPA SHALL HAVE DOOR LATCHES INSTALLED FIVE (5) FEET ABOVE THE FLOOR, MINIMUM. 6. COPIES OF THIS ENGINEERING SPECIFICATION / DESIGN DETAIL ARE TO ONLY BE CONSIDERED VALID FOR PERMITTING OR DESIGN CERTIFICATION PURPOSES WHEN ALL SHEETS OF ANY SUBMITTED SET BEAR5 THE ENGNEER'S ORIGINAL SIGNATURE (IN BLUE INK), UNDER HIS EMBOSSED SEAL. S.D.Q., INC. SHALL NOT BE RESPONSIBLE FOR NON -ORIGINAL COPIES THAT ARE SUBMITTED, THAT HAVE ANY UNAUTHORIZED CHANGES, ALTERATIONS OR DELETIONS ON THEM. 1. THESE ENGINEERING DETAIL DRAWINGS ARE ONLY VALID IF THE DATE ACCOMPANYING THE ENGINEER'S ORIGINAL SIGNATURE 15 LESS THAN 90 DAYS OLD. NO BUILDING OFFICIAL OR BUILDING DEPARTMENT SHOULD ACCEPT COPIES THAT ARE OLDER THAN THIS, AND SHOULD REQUEST THE SUBMITTING CONTRACTOR OBTAIN UPDATED / CURRENT ENGINEERING. 8. ALL ENGINEERING SPECIFICATIONS AND DETAIL DRAWING CONTAINED WITHIN THIS ENGINEERING DOCUMENT ARE THE SOLE PROPERTY OF B.D.Q, INC. ANY UNAUTHORIZED COPYING OR OTHER REPRODUCTION IN PART OR WHOLE OF THESE DOCUMENTS WILL NOT BE PERMITTED AND WILL BE PROSECUTED TO THE FULLEST EXTENT ALLOWED BY LAW. 9. THERE SHALL BE NO REDISTRIBUTION OF THESE ENGINEERING DOCUMENTS BY THE PERSON OR COMPANY THAT ORIGINALLY PURCHASED 516NED AND 5EALED COPIES FROM B.D.Q., INC., WITHOUT EXPRESS WRITTEN AUTHORIZATION FROM B.D.Q., INC., AND THE ENGINEER OF RECORD. Tf GOMPONENT ,5HAPE5 AND 5PEGIFIGATION5 093 Tw /qry .044 Ir .040 .010 � .Y/ 10 B O 3' 2' 2' 2' I 3" 1 x 3 O.B. I x 2 0.5. 2 x 2 x .093 TUBE 2' 2 x 3 "H" 3 x 3 W DIAL. BRACING THE ACTUAL VALUES FOR 'TP' (FLANG--E THICKNESS) AND 'Tw' (WEB THICKNESS) FOR THE VARIOUS 5ELF-MATING ("0 SIZE SELF -MATING MATERIAL ARE INDICATED ON THE TABLE BELOW. w d) nc HOST STRUCTURE WITH OtIC STRUCTURAL GUTTER MANSARD ROOF BEAM SPAN Lu I' ANbAKL) Ft5kA" 1MAT NOT EXCEED AN OVERALL_ ANGLE OF 30° w --I w HOST STRUCTURE WIT STRUCTURAL GUTTER PEAK / GABLE ROOF BEAM SPAN i PEAK BEAM 5PL-ICES MAY NOT A EXCEED AN OVERALL. ANGLE OF 30° SIZE DIMENSION Tf Tw 2xr4 L A00 .045 2x5 L .116 .050 20 L A20 .050 2x7 L A20 .057 24 L .224 .072 9 L(L) .209 .072 9 L (H) f AN .032 A0 L 11/1GT GTt711l TI IOC' II IITI I w C) W�z co �vwUJ ca � � .6 ® 0 ILX, >w Lam U. o ® C) LU LU jj®> �Lue cool ®;EWa �� � � ca _�� ti� inu� = .a�i28 off- _ zM�� W Z CL U_ 0U 04 W tcS cs yj LL �L4 a DESIGN NOTE: ALL THRU-BOLTS PASSING THROUGH ANY ALUMINUM MATL. WITH A WALL THICKNESS LESS THAN 030, SHALL HAVE A 1'i8-INCH (OUTSIDE DIA.) FENDER WASHER l5EE GENERAL NOTE "2 ON SHEET #2 REGARDING SEPARATION OF 01651MILAR METALS). THE CONTRACTORS MAY, IF THEY CHOOSE, INSTALL THE ANGLE CLIPS FOR THE DIAGONAL TUBE BRACING (WHERE IT ATTACHES TO THE SELF - MATING SCREEN ROOF BEAMS) WITH THE THRU-BOLTS ONLY PASSING THROUGH ONE HALF OF THE BEAM. THIS 15 A STRUCTURALLY ADEQUATE ALTERNATIVE, AND WILL PERMIT INSTALLATION OF THESE ANGLE CLIPS IN THEIR SHOP, DURING FABRICATION (POSSIBLY SAVING TIME DURING INSTALLATION IN THE FIELD). NOTE: ALL DIAGONAL BRACING SHALL BE ATTACHED VIA THE 2 x 2 x lia" ANGLE CLIPS, AS SHOWN, AND SHALL HAVE EACH END ATTACHED TO EITHER THE SCREEN ROOF BEAM OR TO THE EVE RAIL. NO DIAGONAL BRACING SHALL- BE ATTACHED TO ANY OF THE ROOF PURLINS DESIGN NOTES: ALL DIAGONAL BRACING, USED EITHER IN THE ROOF, OR AS 'K'-BRACING IN THE WALLS SHALL BE 2" x 2' x .093 WALL THICKNESS TUBE, AND SHALL BE CUT TO FIT SNUG,_WITH NO PLAY OR SHIFT IN THE BRACING. SEE DETAILS AT RIGHT FOR CONNECTION SPECIFICATIONS X UPPER ANGLE CLIP TO BE PLACED AT SAME ANGLE AS THE MANSARD LEG OF THE SCREEN ROOF BEAM 2x3x.01®EVE RAIL 2 x 2 x pia' ANGLE CLIP, CUT AT A 45' (+!-) ANGLE AND ATTACHED TO THE 2 x 3 x .010 EVE RAIL WITH ONE (U 1/¢' DIA. THIRd-BOLT, WITH FENDER WASI4ER (SEE DESIGN NOTE ABOVE 2 x 3 x .010 SCREEN ROOF PURLIN x N 2 x 3 x .010 SCREEN ROOF PURLIN 2 x SMB SCREEN ROOF BEAM (TYP) SPLICE JOINT 2 x 2 x '/a' ANGLE CLIP, CUT AT A 45' bl-) ANGLE AND ATTACHED TO THE SCREEN - - ROOF BEAM WITH ONE (1) 114' DIA. THRU-BOLT, WITH ® FENDER WASHER (SEE DESIGN NOTE ABOVE 2 x 2 x -.093 DIAGONAL ROOF BRACE, CUT AT 45' ANGLE (+/-) AT EACH END AND ATTACHED TO EACH ANGLE CLIP WITH A 1/4' DIA. THRU-BOLT, AS SHOWN TYPICAL ANGLE ARTICULATION TO CREATE UPWARD ANGLE [DIAGONAL ROOF 5RACING DETAIL O ul . I L i9 W 5 way. gn uj �> F—A. M. J - co %oix ��:� LU 0) a -� W r o• w u: o to � lu 0�. cv 4-w cn- GE 5PECIFICATION5 a' el TEK SCREW pICAL) SAME JUST 3� o 0 1 ° o a 0 o ® o o ° 1 \ 1 0 0 ° a 3x; 1 0 o c o® C 1® ° o OF l0 0 ° i __ EEN PURLIN ROOF BEAM COPY � ---I x 2 Oa TOP 'A' BELOW, SCREEN FRAME VERSED 2 x 2 x .093 TUBE DIAGONAL BRACE .010 H 2 UPRIGHT SPLICE PLATE MATERIAL 1 SHALL RE 1/4' THICK (MIN.) AND RE EITHER 06063-T6 OR 06061-T6 ALLOY SEAM 5FL_ICE DETAIL. (2 x 8 IBEAMS AND LARGE "All E ®110-1 0 �N ° 0 ° O V 4-INCH x 4-INCH x 1 0 1 a .010 PLATE, WITH 11 0 0 ° o C (4) 012 TEKS IN THE 1 0 3 x 3,(3) 012 TEK5 ° SPLICE PLATE MATERIAL. IN THE BOTTOM I z O\QI\A SHALL BE 3/16' THICK (MIN.) x 2TAND HE 2 (32 BRAC) t2' 101ALp AND RE EITHER %063-T6 IN OR 06061-T6 ALLOY E3EAM SPLICE DETAIL. (2 x I 15EAM5 AND SMAL-L_ER) -O TYP. F BEAM TYPICAL 3/16'OR 1/4' THICK SPLICE PLATE 3x3°H•,,..�� COLUMN 2x2xOrJ3TI SPLICE PLATE TOLEF:ANCE NOTE; - - DIAGONAL BF ALL 5PLICE PLATES (ALUMINUM I x 2 BOTTOM ALLOY 06063-T(b or 06061-T6) SCREEN FRAt- SHALL BE CUT TO E,E +0.000 / -0,0625, AS INDICATED IN THE SCHEMATIC DRAWING AT LEFT 2x3x910CHAIR RAIL 2 x 2 x ,055 TUBE - DIAGONAL BRACE DETAIL. nA,l (OUT61DE) (INSIDE) I I x 2 05 BOTTOM SCREEN FRAME c 3 'H' GOF 41zN )LUMN 2 x 2 x .093 TUBE DIAGONAL BRACE I x 2 BOTTOM SCREEN FRAME I -INCH x 3-INCH x ,093 ANGLE, CUT 4- INCHES LONG, _WIT H (3) 12 TEKS IN THE 3 x 3, (3) *12 TEKS IN THE BOTTOM I x 2 AND (3) 012 TEKS IN THE 2 x 2 BRACE 2 x SMB UPRIGHT 2 x 2 x .OS3 TUBE DIAGONAL BRACE 0 O 2x3x910 0 0 v CHAIR RAIL o 0 0 0 0 o 2 x 2 x .093 TUBE o° 0 DIAGONAL BRACE 0 0 2 x 5 5MB UPRIGHT (MINIMUM SIZE) (OUT51DE) 2 x 2 x .093 TUBE - DIAGONAL BRACE 2 x 5 5MB UPRIGHT o (MINIMUM SIZE) o 0 2 x 3 x .010 CHAIR RAIL \ I 1 2 x 2 x .093 TUBE - DfAGONAL BRACE (INSIDE) is ® ill ®� uj 4-fNCH x 10-INCH x ; .010 PLATE, WITH (1) 412 TEK5 IN THE SMB UPRIGHT, (3) 12 TEKS C) L LLJ IN THE CHAIR RAIL AND (3) 012 TEKS IN EACH 2 x 2 BRACE 2x3x,010 CHAIR RAIL cK9.J_ r 0- U. LJJ ® Lu m� 0� /—I-INCH x 3-INCH x 0 _ .093 ANGLE, CUT 4- INCHES LONG, WITH (3) 012 TEKS IN THE 5M5 UPRIGHT AND (3) 012 TEKS IN THE 2 x 2 BRACE 2x3x.010 CHAIR RAIL >, �— I -INCH x 3-INCH x '~ - -.093 ANGLE, CUT 4- INCHES LONG, WITH (3) BIZ TEK5 IN THE w >y �- 5MB UPRIGHT AND (3) 012 TEK5 IN THE 2 x 2 BRACE ® tad g �m�; ti 5GIREEN IR00F ENCLOSURE-TO-HOF STRUCTURE ATTACHMENT DETAI DESIGN NOTE: THE 3-INCH LEG OF THE ANGLE SHALL BE PLACED AGAINST THE I x 2. THIS ALLOWS A MIN. EDGE D15TANCE FOR THE FASTENERS (FROM THE EDGE OF THE ANGLE) OF ONE -INCH, AND MAINTAINS A SIX-INCH MIN. CENTER -TO -CENTER DISTANCE FOR THE MAX. SIZED CONCRETE ANCHORS (3/8" x 31/29 CAP ITYP) HOST C.B.S. WALL (TYP) TYP SCREEN ROOF BEAM I x 2 2' x 3' x .125' ANGLE W/ (4) 012 TEKS, TYP, EACH 51DE OF BEAM FA5CIA REINFORCEMENT IDE61GN NOTE: ALL FASCIA BOARDS ON ANY EXISTING HOST STRUCTURE THAT WILL HAVE ANY PART OF THE PROPOSED SCREEN ENCLOSURE ATTACHED TO IT SHALT_ BE REINFORCED, BY PLACING ONE (1) 1/4' x 4' LAG SCREW INTO THE END OF EVERY TRUSS TAIL (WHERE THE PROPOSED SCREEN ENCL06URE IS BEING INSTALLED). THESE TRUSS TAILS MUST BE PILOT DRILLED WITH A 5/32" DRILL BIT TO PREVENT SPLITTING THE END OF THE TRUSS TAILS. IT. SHALL BE THE REP6ON5181LITY OF THE INSTALLING CONTRACTOR TO ENSURE THAT THIS STEP IS COMPLETED, AS SPECIFIED, PRIOR TO ANY INSTALLATION TAKING PLACE. FASTENER SHALL BE 1/4' x 3 1/2' RED -HEAD ITW TAPCON FOR ALL 2' x 6' BEAMS AND SMALLER. FASTENERS SHALL BE 3/0' DIA, FOR 2' x 1' BEAMS AND LANCER (SEE DESIGN NOTE ABOVE REGARDING 3/6 FASTENER SPACING) WALL ATTACHMENT F45CIA REINFORCEMENT 5FECIFICATION5 1/4' x 4' LAG SCREW, TO BE INSTALLED INTO THE END OF EVERY TRUSS TAIL WHERE A SCREEN ENCLOSURE WILL BE ATTACHED. THE T%55 TAIL SHALL BE PILOT - DRILLED WITH A 5/32' DRILL BIT (TO PRIEVEN' SPLITTING THE END OF THE TRUSS TAIL) 10-INCH LONG 025 THICK) EXTRUDED SEE 'SNAP / LAP CONNECTION' 'z' GUTTER INSERT, TYP CENTERED ON NOTE ON SHEET I FOR SPEC.'S EACH ROOF BEAM, WITH FOUR (4) 010 TEKS THRU TOP LIP OF GUTTER .Q 2 x 3 x .125 ANGLE CLIP (CUT 2' LONG-) W/ 3-INCH 1/4' x 21/4' LAG5, FOUR (4) LEG AGAINST I x 2. CLIP IN EACH 10-INCH INSERT ° SHALL HAVE FOUR (4) #12 AND AT 24' O.G. (MAX. N TFKS INTO SIDE OF ROOF SPACING) IN THE REST 0 BEAM AND TWO (2) 014 x OF THE GUTTER (PILOT - -� 2' TEKS (PER ANGLE CLIP) DRILL FASCIA W/ 5/32" N THRU GUTTER AND INTO 7' BIT TO AVOID SPLITTING) GUTTER INSERT (TYP. ONE N ANGLE CLIP ON EACH SIDE OF EACH BEAM) TYP. 2 x SCREEN ROOF BEAM (MAY BE FLAT 5' STRUCTURAL I x 2 SCREEN OR SLOPED) GUTTER (CONT.) FRAME (TYP) FLAN VIEW TRUSS TAIL (TYP/ CAP (TYP) 2 x FASCIA BOARD (TYP) t NOTE: FASCIA ATTACHMENT REQUIRES A 2 x FASCIA BOARD (MINIMUM). A 'I x' FASCIA 15 ONLY ADEQUATE FOR THIS INSTALLATION WHEN THERE IS A 2 x SUB - FASCIA BEHIND IT, IN THIS CASE, THE LAGS MUST PENETRATE THE SUB -FASCIA 11/2' (MIN. EMBEDMENT). IT SHALL BE THE RESPONSIBILITY OF THE SCREEN CONTRACTOR TO VERIFY THE PRESENCE OF THIS 5U5-FASCIA. 10-1 LONG 025 THICK) EXTRUDED - 'ZYtUTTER INSERT, TYP CENTERED ON ACH ROOF BEAM, WITH FOUR (4) 010 TEKS THRU TOP LIP OF GUTTER r 2 x HOUSE FASCIA (SEE FASCIA NOTE ABOVE) 1/4' x 21/4' LAG5, FOUR (4) ----� IN EACH 10-INCH INSERT AND 24" O.C. (MAX,RES SPACININ G) IN THE REST OF THE GUTTER (PILOT DRILL FASCIA W/ 5/32' BIT TO AVOID SPLITTING) - I x-2-x-.093 ANGLE SPACER- (FOR ANGLED FASCIA BD. ATTACHMENT), ATTACHED W/ TWO (2) ROWS OF 010 TEKS STAGGERED), EACH ROW AT O,C. (MAX, SPACING) STRUCTURAL GUTTER CONNECTION TYP SCREEN ROOF BEAM I x 2 2' x 2' x .125' ANGLE W/ (4) 012 TEKS, TYP, EACH 51DE OF SEAM 1/4' x 2 1/2' LAG SCREW TYP. I EACH SIDE OF BEAM (2' x (b' BEAMS AND SMALLER) 3/6' x 2 1/2' LAG SCREW (2' x l' REAMS AND LARGER) FA5C I A ATTACHMENT ENE RE a SEE "SNAP / LAP CONNECTION' NOTE ON SHEET I FOR 6PEC,'5 '---U-CHANNEL CAP (TYP) I x 2 SCREEN FRAME (TYP) 5' STRUCTURAL GUTTER (CON T .) 5ECTION VIEW TYP. 2 x SCREEN ROOF BEAM (MAY BE FLAT OR SLOPED) 2 x 3 x.125 ANGLE CLIP (CUT 2' LONG) W/ 3-INCH LEG AGAINST I x 2. CLIP SHALL HAVE FOUR (4) 012 TEKS INTO SIDE OF ROOF BEAM AND TWO (2) 014 x 2' TEKS (PER ANGLE CLIP) THRU.-GUTTER AND INTO T_ GUTTER INSERT (TYP. ONE ANGLE CLIP ON EACH SIDE OF EACH BEAM) CL o E . J ` FRONT WALL 2 x 2 x 3/16' ANGLE, WITH FOUR (4) 012 TEKS INTO THE UPRIGHT I x 2 OB BOTTOM FRAME AND ONE (1) 3/8' RED -HEAD , 'TRU-50LT' WEDGE ANCHOR 2 3/4°,MIN. EDGE (MIN. OF 4-INCH EMBEDMENT INTO THE CONCRETE) DISTANCE �k 33 x .010 FRONT WALL SIDE WALL ., ORNER UPRIGHT 010 x 2' SMS SCREW, WITH 5/8' DIA. WASHER (6EE GENERAL I x 2 Op BOTTOM FRAME ui z X NOTE 03, SHEET N2) TO BE 18- INCHES, CENTER -TO -CENTER I x 3 05 SIDE -WALL CORNER ? MAX. SPACING UPRIGHT CY PL14N VIEW MANSARD SCREEN ROOF 2 x 3 x .010 EVE RAIL, REAM(BEYOND) TYP. (CONTINUOUS) 2 x 5 x /e' ANGLE (2-INCHE5 LONG) WITH (2) 014 TEKS INTO TOP OF 2 x 3 EVE RAIL AND (2) 014 TEKS INTO THE FRONT I x 2 OB TOP FRAME OF THE 3 x 3 H FRONT WALL CORNER UPRIGHT I x 3 05 SIDE -WALL CORNER UPRIGHT _ 010 x 2' SMS SCREW, WITH 5/8' DIA. WASHER (SEE GENERAL NOTE 03, SHEET 02) TO BE IS - INCHES, CENTER -TO -CENTER 3 x 3 x .010 FRONT WALL MAX. SPACING CORNER UPRIGHT , 2 x 2 x 3/16' ANGLE, WITH FOUR (4) 012 TEKS INTO THE UPRIGHT AND ONE (1) 3/8' RED -HEAD 'TRU-BOLT' WEDGE ANCHOR 2 3%', MI . DGE (MIN. OF 4-INCH EMBEDMENT DIS CE INTO THE CONCRETE) 0 0 I x 2 OB BOTTOM FRAME ELEVATION VIEW -_- CORNER-UP-RIHT-[DETAIL NOTE: THIS ATTACHMENT I x 2 0,5. SCREEN FRAME, DETAIL ALSO APPLIES TO TYP. BETWEEN UPRIGHTS A 2 x 2 SCREEN FRAME, OR AS FRIGHTS AGAINST W/ THE FASTENER SEINE A W OR COLUMN 4' IN LENGTH, TO I/ ' IA, x 31/4' TAPCON MAINTAIN A 2' MIN. EE PLACED AT NO MORE EMBED, HAN 18' O.G. (RE: GEN. NOTE 03) MIN. EMBEDMENT FOR CONC. / C.5.6. / MASONRY ALL TAPCONS SHALL SURFACE BE 2' INTO CONCRETE. NOTE: ALL FASTENERS 516ECIFIED IN 'COLUM-TO-FOUNDATION' DETAILS PERTAIN ONLY TO THE FASTENERS TO 5E PLACED ON EITHER SIDE OF COLUMNS, THIS DETAIL IS FOR ALL INTERMEDIATE FASTENERS FOR I x 2 SCREEN FRAME TO EITHER CONC. DECK OR C.B.S. MASONRY WALL. 2 x 3 x .010 ROOF PURLIN 2 x 5 X.010 EVE RAIL, TYP. (CONTINUOUS) 2 x 5 x /a' ANGLE (2-INCHES LONG) WITH (2) 114 TEKS INTO TOP OF 2 x 3 EVE RAIL AND (2) 014 TEK6 INTO THE FRONT OF THE 2 x SM5 SIDE WALL UPRIGHT I x 2 O5 TOP FRAME 010 x 2' SMS SCREW, WITH 5/8' DIA. WASHER (SEE GENERAL NOTE 03, SHEET 02) TO BE IS - INCHES, CENTER -TO -CENTER MAX. SPACING 2 x 5 SMB UPRIGHT (MINIMUM SIZE FOR ANY UPRIGHT ON A SCREEN ROOF ENCLOSURE) 234' MIN. EDGE DISTANCE SEE 'MINIMUM FOOTER —� TABLES° -ON SHEET 0I- 0 0 0 21/a' x 11/2' U-CHANNEL CLIP ATTACHED TO THE EVE RAIL WITH SIX (6) 012 TEKS, AND (3) 012 TEKS INTO EACH 61DE OF THE 2 x 3 ROOF PURLIN (TO BE ATTACHED ON THE TOP END TO THE SCREEN ROOF BEAM IN THE SAME MANNER 2 x 4 x /9' ANGLE (2-INCHES LONG) WITH (2) "14 TEK6 INTO BOTTOM OF THE 2 x 3 PURLIN AND (2) 014 TEKS INTO THE SACK OF THE 2 x SM5 SIDE WALL UPRIGHT 2 x 3 x .010 CHAIR RAIL (TYP) 2 x 2 x 3116' ANGLE, WITH FOUR (4) 012 TEKS INTO THE UPRIGHT AND ONE (I) 3/0' RED -HEAD °TRU-BOLT' WEDGE ANCHOR (MIN. OF 4-INCH EMBEDMENT INTO THE CONCRETE) I x 2 OB 50TTOM 6I[DE WALL UPRIGHT DETAIL a �,s 5r� w BEAM SIZE 2x5-2x(o 2x7-2x8 2 x 9 2x10___� 2 x SMB SCREEN ROOF BEAM 2 x 3 x ,010 ROOF PURLIN NO, OF 014 TEKS _ (PER 51DE) (2) 014 TEKS (4) 114 TEKS (5) 014 TEKS (6) 014 TEKS 0 0� 2 x 5 x'%' ANGLE l2-INCHES —,//) LONG) WITH (2) 014 TEK6 INTO 0 01 TOP OF 2 x 6MB SEAM AND (2) 014 TEKS INTO THE FRONT 0 0 l OF THE 2 x SMB FRONT WALL UPRIGHT I x 2 05 TOP FRAME -' 1 #10 x 2' SMS SCREW, WITH 5/8' DIA. WASHER (SEE GENERAL NOTE a3, SHEET #2) TO BE 18- INCHES, CENTER -TO -CENTER MAX. SPACING 2 x 5 SMB UPRIGNT (MINIMUM SIZE FOR ANY UPRIGHT ON A SCREEN ROOF ENCLOSURE) SCREEN ROOF BEAM SHALL OVERLAP ON THE OUTER SIDE OF BOTH SIDES OT THE UPRIGHT (TYP. EACH BEAM -TO -UPRIGHT CONNECTION) SEE TABLE ABOVE FOR NUMBER OF 114 MKS, AS SPECIFIED BASED ON BEAM SIZE 2 x 3 x .010 CHAIR RAIL (TYP) 2 x 2 x 3/I6' ANGLE, WITH FOUR (4) 012 TEKS INTO THE UPRIGHT AND ONE (1) 3/8' RED -HEAD °TRU-BOLT° WEDGE ANCHOR (MIN. OF 4-INCH EMBEDMENT INTO THE CONCRETE) 23/4' MIN, EDGE DISTANCE 0 0 1 x 2 OB BOTTOM FRAME 0 0 SEE 'MINIMUM FOOTER --TABLES' ON SHEET 11 -- - - - 33/4' 3' MIN. MIN, FRONT WALL UPRIGHT [DETAIL as s;