HomeMy WebLinkAboutSUBMITTED PAPERSOFFICE USE ONLY:
Date 26_ 0 7 Fee Due: Receipt# Permit #6 log, b�5
ALL INFO MUST BE COMPLETE. &FILLED INTO BE ACCEPTED
St. Lucie County Building and Zo.:ing n
2300 Virginia Avenue ��
SCANNED Pierce, FL 34982-5652
BY 772-462-1553
St. Lucie COuntjt
APPLICATION FOR ALUMINUM STRUCTURES PERMIT
PROJECT INFORMATION
1. LOCATION/SITE ADDRESS: 8912, Champions Way , Port Saint Lu@ie, F
2. S/DNAME:Lakes @ PGA Village SITE PLAN NAME:
3. PROPERTY TAX ID #: 3334-501-0067-000-0 ✓
4. LEGAL DESCRIPTION (attach extra sheets if necessary): Lakes @ PGA Village Blk A Lot 53
M
5. PLAT 6. PAGE 7. BLOCK 8. LOT
BOOK NO. NO. A NO• 53
9. PARCEL SIZE: ACRES/SQ FT. V �' LOT DIMENSIONS 140 -tQ X .84 X 1UQ u4 2
✓ v
10.. SETBACKS (ACTUAL) FRONT:" BACK: -�p_RIGFIT SIDE:_6 - LEFT SIDE: �9
11. TYPE OF STRUCTURE (CHECK ALL APPROPRIATE BOXES FOR EACH AND EVERY TYPE OF STRUCTURE)
TYPE OF CONSTRUCTION
N=New
A= Addition
R = Rebuild
SG = Slab on Grade
SR = Raised Slab
WD = Wo d Deck
DIMENSIONS
rj
SQUARE FEET OF
CONSTRUCTION
92
SCREEN ROOM
N
NE
.tom
�—%�zwQ--
.�mr..�
40 X 19
760 6 8•
❑
CARPORT/PATIO ROOF
❑ NEW
❑
EXISTING
X
❑
HABITABLE GLASS ROOM
❑ NEW
❑
EXISTING
X
❑
SUNROOM
❑ NEW
❑
EXISTING
X
❑
SHED
❑ NEW
❑
EXISTING
X
❑
POOL ENCLOSURE
❑ NEW
❑
EXISTING
X
❑
M H ROOF OVER
❑ NEW
❑
EXISTING
X
❑
POOLFENCE
Linear feet
❑ ROOF SYSTEM OVER
EXISTING ACCESSORY STRUCTURE
❑ NEW
❑
EXISTING
X
OTHER
N
NEW
❑
EXISTING
1 X 1
66 LN FT
TOTAL SQUARE FOOTAGE OF CONSTRUCTION
760
12. VALUE OF CONSTRUCTION• $'p.82+- a 5 I l S
The value of construction is used to det ne the a t of perm fees to 6� assessed. St. Lucie County reserves the right to
question and/or modify the indicated value of cons ction if it is demonstrated that the submitted figures are not consistent with
similar types of construction activities. If the value i $2500 or more, a RECORDED Notice of Commencement must be submitted
PRIOR TO FIRST INSPECTION. G GN`� t i-p 2 P lzo V i D J�7_ _0
SLCCDV Form No.: 001-02 Rev. 2119107 d 0 1=
OWNER INFORMATION
ADDRESS: (8912 Champions Way)?c Gt'O% (SiX
CITY: Port Saint Luc0DWaAXJh STATE: FL Ff:�- ZIP l34953 J_nJ!bB_
PHONE (DAYTIME), • (4121 828-3164- email:
FILL IN NAME AND ADDRESS BELOW IF THE ,FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM
THE OWNER LISTED ABOVE: ? - J� �)o
FEE SIMPLE TITLEHOLDER:
ADDRESS:
CITY: STATE: ZIP
PHONE (DAYTIME): ( )
CONTRACTOR INFORMATION
STATE OF FLORIDA REG./CERT #: 6-7 63 ST. LUCIE COUNTY CERT #: 4763
BUSINESS NAME: Pioneer Screen Co Inc II
QUALIFIER'S NAME: Michael J Newman
ADDRESS: 1682 SW Biltmore Street
CITY: Port Saint Lucie STATE: FL ZIP 34984
PHONE (DAYTIME): (772) 340-4393 FAXNO.772-340-4626 emai ioneerscreen@msn.com
:RCHITECT/ENGINEER: BDQ, Inc
'LDRESS: 1950 NE 170th Avenue. Via'
CITY: Williston STATE: FL ZIP 32696
PHONE (DAYTIME): Q52) 529-0080
NOTE: IF APPLICABLE, SUBCONTRACTOR AGREEMENTS MUST BE ATTACHED TO APPLICATION FOR
ROOFING, ELECTRIC, PLUMBING, AND HVAC;
ZONING REQUIREMENTS' r°
Al;r2
h structures will be subject to the requirements of the ST. LUCIE COUNTY LAND DEVELOPMENT CODE.
scaled plot plans showing lot size, dimensions of existing host structure, -and proposed aluminum addition. All setbacks
including front, side, rear and distance between adjacent property structures in MH Parks shall be indicated on the plot plan..
❑ 2 sets of color photos for all storm damaged areas to be reconstructed. One picture must include house address number for
inspection verification. ( not required for construction unrelated to storms)
OFf'ICE USE ONLY'
ZONING
t Y
{
SECTION
TOWNSHIP
RANGE
'? E
— `
MAP NO.N
ZONING
V
�U V
LAND USE
R 5
LOT CVG %
a
Additional
Pemuts
Yes
no
t-
-
REPORT
CODE
to
BIMS FEE
MISC FEES
TOTAL FEES
BUILDING °& ZONING REVIEW.
•.
REVIEWS
ZONING
ZONING
REVIEWED BY
PLANS
EXAMINER
MISC.
I
VEGETATION
I
VALUE OF CONSTRUCTION
USING ICC TABLE
DATE
COMPLETE I I I L I I 4912�
INITIALS _ ., _A
f
PLAN REVIEW SPECIFICATION CHECKLIST
PLEASE PROVIDE ONE OF THE FOLLOWING:
2 Sets of Detailed Plans: Dated, Signed & Sealed by an Engineer or Architect holding a Florida State professional license.
❑ 2 Sets of Detailed Plans: Designed in accordance with the AAF Guide To Aluminum Construction in High Wind Areas.
(1) ANY PLANS SUBMITTED WITHOUT COMPLYING WITH THE FOLLOWING SHALL BE RETURNED WITHOUT
APPROVAL. ALL PLANS MUST BE IN INK AND ANY NOTATIONS IN PENCIL WILL NOT BE CONSIDERED A PART OF
A SUBMISSION.
• All plans must be legible and must be designed in Architect's Scale on pages which are 81/2" x 11" or larger.
• All relevant tables & details, if using the AAF Guide, must be properly highlighted and must match design checklists &
drawings.
• The plan view must include all dimensions; the location of the host structure and all materials must be sized and
identified thereon.
• All elevations must be shown, including 4`s wall detail, dimensions and all material must be sized and identified.
• All primary and secondary carrier beams, spans, spacing, gauges must be shown [Example: 2" x 8" x .072"].
• All methods of fastening or other details which are relevant to the design must be identified on the Plans.
• All upright column heights, sizes, spacing and gauges must be shown as follows: [Example: 3" x 3" x .050"].
• All chair -rails, roof purlins, girts, channels, knee -bracing, k-bracing, cable bracing or any other required component must
be sized and identified.
• All ridge beams and super gutter or fascia attachments must be identified.
• All roof pans or composite panels, with gauges and spans, must be sized and identified.
• All footing, slab and ISO pier designs must be on the plans, per the Architect / Engineer's plans & specifications.
• All light metal alloys which are utilized shall be designed in conformity with the Florida Building Code of 2.004, Chapter
20, including 2006 revisions.
• Barrier railings, if utilized, shall have all materials, fasteners and height specified and shall have self -closing, self-
catching gates with picket spacing.
(II) SITE CONSTRUCTED SHEDS, HAVING ANY ALUMINUM COMPONENT, SHALL MEET ALL OF THE ABOVE .
REQUIREMENTS AND THE FOLLOWING ADDITIONAL ITEMS:
(A) 2 copies of the current product approval [i.e. N.O.A. or State of Florida approval] with the proposed "opening" or cladding
component. highlighted and with fasteners and design pressures, per FBC 1714, clearly identified.
(B) 2 electric schematics; in accordance with the N.E.C.,.if applicable.
(C) Design pressures, per Table R 30i.2-(2), identified on the openings of all Plans.
(III) HABITABLE ROOMS/ADDITI'ONS-DESIGNS'SHALL MEET ALL OF THE ABOVE REQUIREMENTS, EXCEPT AAMA
SPECIFICATIONS, AND CHAPTER 13 OF THE FLORIDA BUILDING CODE.
(IV) SUNROOMS (as defined in R202 or FBC1202.1) MAY BE CONSTRUCTED; SO LONG AS THEY MEET ALL OF THE
ABOVE REQUIREMENTS AND MUST BE IN STRICT COMPLIANCE WITH AAMA/NPEA/NSA2100.02 AND MEET THE
FOLLOWING ADDITIONAL ITEMS:
(1) The designer or engineer will state on all Plans, which Category of Design [3.1.2] will be used, inclusive of the definition.
(2) If designing a Category 4 or Category 5 structure, as defined in the current Edition of 3.1.2.4 and 3.1.2.5, proper energy
calculations and long form equipment sizing calculations shall be required, pursuant to Chapter 13 of the current State of
Florida Building Code.
(V) MOBILE HOMES (FAC 15C-2.0081 - FAC 15C-2.0072): ALL STRUCTURES ADJACENT TO OR NEW ROOF SYSTEMS
(Pan or Composite) OVER EXISTING ADJACENT STRUCTURES TO A MOBILE HOME SHALL REQUIRE:
(a) A 4`s wall or a current, signed original manufacturer's attachment approval letter which includes the model number, serial
number and current owner's name and street address.
(b) That the complete guide to H.U.D. specifications be strictly adhered to.
(c) A Certified Florida Engineer may design the manner of attachment of the proposed structure to the host house but shall
assume full responsibility for both structures' integrity by site specific documentation.
CERTIFICATION:
This application is hereby made in order to obtain a permit to do the work and installations as indicated, and to obtain a
certificate of capacity, if applicable, for the permitted work.
NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU.:
PAYING TWICE FOR RVIPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO
OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT.
NOTICE TO APPLICANT: IN THE EVENT IT IS NOT YOUR RIGHT TITLE OR INTEREST THAT IS SUBJECT TO
ATTACHMENT, THE APPLICANT DOES HEREBY MAKE A GOOD FAITH PROMISE TO
DELIVER A COPY OF THE ATTACHED CONSTRUCTION LIEN LAW NOTICE TO THE
PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT, AND DOES SO AS A
CONDITION PRECEDENT TO THIS PERMIT
1. If utilizing the AAF Guide to Aluminum Construction in High Wind Zones, I the Contractor/Owner Builder hereby certify
that the components being used, fasteners type and fastening pattern meet all the requirements for the designated wind
zones established by the county and take full responsibility for complying with the submitted design of the structure being
permitted.
2. I further certify :that all the foregoing information is accurate, that no work or installation has commenced prior to the
issuance of a permit and that all work shall be performed in compliance with all applicable laws regulating construction and
zoning in this jurisdiction: I und6rstand ihat"separate permits may be required for ELECTRICAL, and HVAC, etc., not
otherwise included with this building permit application.
3. I , the Contractor / Owner Builder, have verified that the existing foundation meets the requirements of the Engineer of
Record and is in adequate condition to withstand the uplift and weight of the aluminum structure and said structure will not
exceed the fo rint of a structure that was in existence prior to removal by the storms.
OWDffCONTACTOR SIGNATURE
t.
STATE OF FLORIDA
COUNTY OF` A-. VXAC .
The foregoing instrument was acknowledged
before me thisQ day of tf _, 20gD by -
�..� Oklo ,._.._, ESQ Iio is personally
known to me or who has produced
Cr Ss art. A as' entification.
Signature of Notary
Apo Kevin J Stewart
(SEAL) d� My Commission DD354413
w Expires October 29, 2008
IMPORTANT NOTICES:
SIGNATURE
STATE OF FLORIDA
COUNTY OF Sk . �
The foregoing instrument was acknowledged
before me this50 day of0a`l by
�Ald rno I mo+—inn who is personally
known to me or who has produced
.c-. as identification.
Signature of Notary
Kevin J S4ewrart
(SEAL) e9
y� ,g My Commission DD354413
Sao, �cl? Expires October 29, 2008
• TWO (2) SIGNATURES ARE REQUIRED. EACH SIGNATURE MUST BE NOTARIZED. IF APPLYING FOR THIS
BUILDING PERMIT AS AN OWNERIBUILDER, THE OWNER MUST PERSONALLY APPEAR TO SIGN THIS
APPLICATION IN THE OFFICE LISTED ON THE FRONT OF THE APPLICATION.
• ALL SIGNATURES ON APPLICATION SUBMITTED SHALL BE ORIGINAL. COPIES, FAXES, OR STAMPED
REPRODUCTIONS ARE PROHIBITED.
• WHEN A PERMIT IS AVAILIBLE FOR ISSUANCE BUT IS NOT PICKED UP WITHIN THIRTY (30) DAYS AFTER
NOTIFICATION OF AVAILIBILITY, IT WILL BE VOIDED. IF THE APPLICATION IS RESUBMITTED, AN
ADDITIONAL FEE WILL BE CHARGED.
41
Code Compliance Division
Ft Pierce, IL 349 2 INSPECTION CARD
Ft Pierce, FL 34982
Phone: (772) 462-1553 Fax: (772) 462-1148
http://stl ucieco.gov/ce
Permit #: SLC- 0709-0325 Conf #: 661 Type: Building (Miscellaneous)
Issued 10/16/2007 Status: FIN Double Fee: No
Job Location 8912 CHAMPIONS WAY City: PORT ST LUCIE
Jurisdiction: St. Lucie County Lot: Block:
Parcel: 3334-501-0067-000/0 - Subdiv: LAKES AT PGA VILLAGE
Flood: Elev: Flood Map:
Job Description: NEW CONSTRUCTION OF 36.75 X 19 SCREEN ROOM ON NEW PERIMETER FOOTING.
Setbacks Left; 10.00 Right 6.00
Inspection Notes:
Front
Rear: 30.00
Contractor NEWMAN MICHAEL J
PIONEER SCREEN COMPANY INC II (772) 340-4393
1682 SW BILTMORE ST
PORT ST LUCIE, FL 34984
Property Owner JERRY FERRONE
(412) 828-3164
8912 CHAMPIONS WAY
PORT ST. LUCIE, FL 34953
Property Owner KAREN FERRONE
(412) 828-3164
8912 CHAMPIONS WAY
PORT ST. LUCIE, FL 34953
Permit # Status PT Cert #
SUB -PERMITS
DBA Owner / Builder
Job Description
INSPECTIONS - For Requests, Call: (772) 462-1261
Permit # Code Description
Priority Date Sched. Res Description
Inspector
Date Insp.
0709-032E 110 Footer/Foundation
1 10/19/2007 90 Approved
Shaun Milligan
10/19/2007
10/18/07 incall schedule with jody/ contr.
bac
0709-032E 121 Termite Spray
1 10/19/2007 90 Approved
Shaun Milligan
10/19/2007
0709-032E 904 Fastners
2 12/03/2007 90 Approved
Shaun Milligan
12/03/2007
0709-032E 999 Final Inspection
2 12/03/2007 99 Final Approval
Shaun Milligan
12/03/2007
null
Scheduled: Fri Nov 30 14:29:04 EST 2007 with value: Mon Dec 3 00:00:00 EST 2007
Permit Nun 0709-0325
r3
4
St tulle County Inspections.
2300 Virginia Avenue
ri t-Pierce, FL 34982
('772) 462-2172 .
CERTII+ICAT.IE OF T]ERMIT1E TREAT) EN'T
CONSTRUCTION SOIL TREATMLt NT
PKkA l
BUILD
PEST {:ONTRUL CO NTRACTUR 1856 SW Bayshora 131 yd
Pori~ St Lucie, FL 34984
PEST CONTROL LICENSE It
We, the undersigned, hereby certify that we have pretreated the above -described construction for
subterranean termites in accordance with the standards of the National a Control Association.
Square feet of area treated: ® Chemicals used:. /
Pereentage of solution: z
Date of trea ent:
sooting
❑ Tst TretiMient
❑ Ro-treat
❑ S lab
❑ lsl Treatment
❑ P.e-treat -,
❑ Driveway
❑ 1st Tretthndnt
❑ Re-it'ettt
❑ Pools
❑ 1st Treatment
❑ Re -treat
Total gallons used:
Time of Treatment:_,
FRC104.2.6 Cerl(fleateofProtecllveTrealtnenlforprepenllottafaer�iiiles.
A weather reslslanl jobsile posting board shall be provided to receive
duplicate Treatment Certificaies as each regtlitell prorective treaunent is
completed, providing a copy for the person the permit Is issued to and
another copy for the bttildlug permit fles, The Treatment Cerdjicale shall
provide the pro(hict used, idenlity'of the applicator, time mil date of the
treatment, site loc'atia)1, area treated, ehemicdl used, percent concenUation
and number of gallons used, to etlablish a verifiable record of protecllve
tre,ohnent. , If the soil chemical bart•ler method for termite prevettilon lr used,
final exterior trealment shall be completed prior io final building approval.
St Lucie County requires for the final inspection for CO, a Perinanent
Sticker to be placed on the electrical panel box cover, listing all the
treatments and, dates of appliea't➢ons. ,
❑ Other
�❑ 1st Treatment
❑ Re -treat
❑ Perimeter -for Final Inspection
NOTE:
There must be a completed forin for each required treatment or re -treatment mid.this form must be oil
Me job site to be picked up by the inspector at time of each hispectiolz or the Scheduled hisImctiou vill
fail and a re-inspe.etion fee charzed. .
BILLING INFORMATION I� INSTALLATION INFORMATION
�r.wr""fliwWfAw
FINANCE COMPANY (IF APPLICABLE)
NAME OF PARTIES
Code Compliance Division
2300 Virginia Avenue
Ft. Pierce, FL 34982
Phone: (772)462-1553 Fax: (772)462-2522
http://stiucieco.gov/ce
Date: 26 September 2007
Job Address: 8912 CIIAMPIONS WAY
Received By: spellsv
Paid With: CK
Paid By: PIONEER SCREEN CO,.
Building
Receipt
Sign:
Receipt#:
0000057678
ermit Number:
SLC- 0709-0325
- Amount:
$50.00
.redit Card Number:
Check Number:
47895
-�t �117-4 Building
Code Compliance Division Receipt
2300 Virginia Avenue
Ft. Pierce, FL 34982
Phone: (772) 462-1553 Fax: (772) 462-2522
http://stiucleco.gov/ce
Date:
16 October 2007
Receipt #:
0000058197
Job Address:
8912 CHAMPIONS WAY
'ermit Number:
SLC- 0709-0325
Received By:
goycochb
Amount:
$130.00
Paid With:
ck
i . edit Card Number:
'tC-hbck Number:
47981
Paid By:
pioneer screen
Sign:
•09/14/2007 14:40 7723404626
AF-32R itECr7 WG-RETURN TO!
PIONEER SCREEN CO II
PAGE Si
%i304N M. FPY. _r_. rLERV OF THE CIFC WT CG0te„
SAIMT LUCF Cl)UNT1
lei_ OT�CE O F COBOR CQ 1ONT
The undersigned hereby given -,notice that improvement wil 1 be made to certain real proper, and is accordance with Chapter 113,
FlbnidA vtnmtes the following itfomation i s provided in the Notice of eotntriencemeot
1. DESCRIPTION OF PROPERTY (I FA description of d street address) TAX ML11D NUMRER��U $pl t�0i• OOU 0
SU8D1V1SIt)1Y BLat:IC TiIACT LOT,�31aLDG UNIT- ----
2.(;liNERALDESCRIPTIONOF'xnIIRRO%'1EhIE§r:Install Screen / Pool _Bnclosure
3, OWNER INFORMATION: aNamee-Xr -
b. Addross�l `,�Cit'�at��A�4 �b �e ���5�-.�„ lf��•t iZ c. inteaeat in properry�
d. Name and address of fee simple titleholder (if other th to owner)
r4, CONTRACTOR'S NAME, ADDRESS AND PHONE NUM1 EM Pioneer Screen Co Znc II
1682..5W.-Biltmore Stre.er- Port Saint: Lucie, FL 34984 . (772) 340-4393
5. SURETY'S NAME, ADDRESS AND PHONE NUME Eli AND BOND AMOUNT:
6. LENDER'S NAME, ADDRESS AM PHONE' "MlI ER:
7, Persons within tho State of riorida designated by Owner upon whom notices or other documents may bt setvtd as provided by
Section 7.13.13 (1)(a) 7., Florida Statutes:
NAME, ADDRESS AND PHONE NLWISR:
S. In addition to himself or hcrsol& Owner desipates the fc Ilowing to receive a copy of the Lienor's Notice ae provided in Section
713..13 (1)Cb), Florida Statutes:
NAME, ADDRESS AND PHONE NUVi HER:
9. Expirntion date of tsotice of commencement (the expinti. In date is 1 year from the date of recording unless a diZerent date is
specified) 20
gniture of Owner or Print Nam and Provide Signatory's-Title/Office
Owner's Authorized 0ficelADlrectorJPariner1Msnager
State ofMorld®
County off A chjL ,
The;forcgoing instrument wes'rlckriowledged,before me thi s day o=y✓`.C' 120
(Name of perre) (Type of sutharity...e.g. Oumer, officer, trustee, attorney in fact)
For -
(Name of party on, behalf of whom instrument woaislwfT?:
+. t K"Jftoaft
• My CommiWon DD354413
(Py cued Name of Notary Public) (sr mu a of Notary Public) Ear elk empires �� 2g, �
Under pomaltios of perjury, I dcolom that 1 have read the 'ongoing and that tho facts in it are true to the best of my knowledge and
belief (section92525; Florida statutes);
snansiture(s).of.O.w.ner s) or. •ner($ A4t torivid 011lcerMrectorMartner/Msnager who sload above-,
toll
`,, t _ %z 7 t !' S p F i `a r1d�.% n° I 'r7•[� J`a'�% /-"' R ff,: �' -v
Y �t�,./"WG•"JL.. i• r.
ai• .:F' rs f. s:�' , ,s(gl�@ttrre .ti zF yi7� t �F..'.1. �.' ". ��Q' `-.s.ia Z�r t �.Lt�/`-',l,ri �pr7L'tCi�=�i{XStle)E_� y ,� Ss:. � r i/,-_
pM KAREN FERRONE
412 828 3164
P. 02
ir
c7p
g rl
&=12030126"'
ti
R-295,00'
L-154.40'
LOT 54
W.-
LOT 52
. . ...............
-)UNDA
i"Egr "Itpry MAI n115 M(NDA4), "Wr A
t�A MK AND COWpT nvp f OMM 4W A
'of RX po' I
WT$ArJW0riWrVlpW -A -lt> U'o n 6EC Vl
5CAL (OYV
A 'W
PA Mw 614 w
CI de
y
McNeal Mrs
���7,,
rt ?Lr a Ml"'WAL PROfTSPONAL RAMYOR 4110 MAPPER 12,ffdj
MIN. SETBACK REQ.
FRONT
Ro
r
311DESES C1413 �I'Epts-3j
REAR I
ZNG,
'6 -,
14 '112'0
L= 36.42
PAGE Z OF 2 PAW
SERVING
M05T FLORIUA COUNTIES
TARGET S URVE YING, I W.
LD 6,Z5
51JI1E 210 SIATYWIOF UUMPERS
MT PALM BEACH, FL 33407 PHONE fV00) 274 -4007
PHOIC (501) 1140-4800 (800) 741-0576
rAUSIMILL
AUG—,30-2007 01:09 PM KOREN FERRONE
412 82$ 3164
i
f
V*,
44,
R-295,00'
L=154.40'
L."
L QT 54
11
LOT 52
VIE Y
B U N D A R Y c 1,J
I I I r r"fo.s I r swwr
4 A TR r $MTA?t*v OF A
VEY MY wrenw,
r AUNOWA)TV RferRem;
111�o
A A7 ,4 "gM 59T&r
Clyde
McNeal
rt, YLf' o mwrZ Pporrys,WAt 'SORWYOR ANO V,4PFfR J208J
MIN, SEMACK REQ.
.FRONT�g
SIDES
51 E�: r�
ZNQQ
0 kp
'
R
14*12'0
R= 155,0(
L=X42
ti
PAGE 2 OF 2 PAGES
SERVING
M05T FLORIUA COUNTIES
JARGET SURVEYING, INC.
LB #6135
$501 CORPORAlt WAY SWITE 219 VATEMOr Misr DERS
WE$T FAIN BEACH. PL 34407 plioNt (m) 226-4no
PADNE (561) 640-4800 rACSIMiLt (800) 741-0576
�`� � C'm�/cre�e t��ers'
�N �. #..�RebdrS COW.
od KL -S l�' R�N�%�qj�.ru-
.DESIGN NOTES:
I. ALL DIAGONAL BRACING SHOWN IN BOTH THE ROOF AND
WALLS SHALL BE 2 x 2 x .093 TUBE MATERIAL.
2. IS x 14 MESH SCREEN IS THE MAXIMUM ALLOWABLE DENSITY
FOR THIS ENCLOSURE'S DESIGN.
3. DOOR(S) MAY BE PLACED INTO ANY SCREEN WALL PANEL
EXCEPT FOR THOSE THAT CONTAIN DIAGONAL BRAGING.
a
OVERALL DESIGN COMPLIES WITH THE 200(o
AMENDMENTS TO THE F.B.C. 2004 BUILDING
CODE, FOR 140 MPH WIND LOAD (3-SECOND
GUST), FOR EXPOSURE CATEGORY "15
TH15 5YM50L REPRESENTS DIA60NAL
0 T1415 SYMBOL REPRESENTS 0 WIND BRACING (IN BOTH THE RODE
BEAM SPLICE LOCATIONS AND WALLS), 2 x 2 x .093 TUBE MATL.
SITE-SPECIPIC NOTE: �(
THIS JOB IS BEING INSTALLED OVER o
A BRICK PAVER DECK, AND SHALL x
HAVE A 12 - INCH x 12 - INCH ISOLATED X
FOOTER, WITH TWO (2) #5�, CONT. ON
ALL THREE SIDES OF THE ENCLOSURE.
EXISTING HOST STRUCTURE
OVERA"
WIDTH
6' (o'
Ix2
X
x
(TYP) x
X
N
Cv
N
N
2 x 3 x .010
PIONEER SCREEN Co., 11
SCREEN ROOF ENCLOSURE FOR:
X�gu)
C1, j OL
ST. LUCIE COUNTY BUILDING DIVISION
REVIEWED FOR COMPLIANCE
REVIEWED BY 4"
DATE -U/D-41) -07
PLANS AND PERMIT MUST BE KEPT ON JOB
OR NO INSPECTION WILL BE MADE.
0-7 Oq - o3a S
THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
COMPLY WITH ALL APPLICABLE COAEB,
®
M
�coU
co z 0
0,
�- 0
NJ 9 0
0
inn
co)
W
0:
-6-0,9
no
Q
UJ
�,. �0
0
LL W % d
z=w
a
moo
U)a
F,45RICATION / INFALL.ATION REQUlREp GUIDELINES:
NOTE: ANY J056 THAT REQUIRE SITE -SPECIFIC DESIGN / ENGINEERING MUST BE
-SUBMITTED TO THE ENGINEER OF RECORD FOR SUCH DESIGN CONSIDERATION
PRIOR TO THE JOB BEING PERMITTED, FABRICATED OR INSTALLED. LEAD-TIMES
FOR SUCH WORK WILL DEPEND ON OUR CURRENT WORK LOAD AT ANY GIVEN TIME.
THE ITEMS BELOW ARE NOT PERMITTED ON ANY
ENCLOSURE WITHOUT SITE -SPECIFIC DESIGN 4
AUTHORIZATION FROM THE ENGINEER OF RECORD.
I. NO SCREEN ROOF BEAMS SHALL BE LOCATED WITHIN 12-INCHES OF ANY OUTSIDE
CORNER OF ANY WALL, FASCIA OR STRUCTURAL GUTTER.
2. NO CABLE BRACING SHALL BE USED ON ANY ENCLOSURE AT ANY TIME FOR THE
RESISTANCE OF ANY IMPOSED DESIGN LOADING.
3. THERE SHALL BE NO SUBSTITUTION OF EITHER CONCRETE ANCHOR TYPE OR
MANUFACTURER OTHER THAN THOSE SPECIFIED ON THESE ENGINEERED DESIGN
DRAWINGS.
4, THERE SHALL BE NO SCREENING UTILIZED THAT IS FINER THAN 18 xJ4 MESH
SCREEN WITHOUT SITE -SPECIFIC DESIGN (THAT SHALL BE DONE PRIOR TO THE
JOB BEING FABRICATED OR INSTALLED) WITH JOB DRAWINGS BEARING THE
ENGINEER OF RECORDS ORIGINAL SIGNATURE (IN BLUE INK) UNDER HIS
EMBOSSED SEAL.
5. ALL SCREEN ROOF ENCLOSURES MUST BE POSITIONED ON THE EDGES OF THE
CONCRETE DECK 50 THAT THE OUTER SURFACE OF THE SCREEN FRAME IS NO
LESS THAT 2 3/4 - INCHES IN FROM THE EDGE, TO CREATE PROPER EDGE: DISTANCE
FOR THE SPECIFIED CONCRETE ANCHORS AT THE BASE OF EACH COLUMN.
6. ALL ROOF pURLINS IN THE ROOF AND CHAIR RAILS IN THE WALLS SHALL NOT
EXCEED 8-FEET CENTER - TO - CENTER SPACING (SEE APPROPRIATE DETAILS ON
OTHER SHEETS OF THIS DRAWING FOR SPECIFIED MATERIAL SIZES REQUIRED FOR
ANY GIVEN APPLICATION.
1. NO SCREEN ROOF ENCLOSURE SHALL BE INSTALLED UTILIZING SEvEN-INCH STRUCTURAL
GUTTER, AS IT IS NOT PERMITTED, OR STRUCTURALLY ADEQUATE UNDER THIS ENGINEERING.
THE ITEMS BELOW MUST BE 51JBMITTED TO THE ENGINEER
OF RECORD PRIOR TO MEASURING 4 LAYOUT, FABRICATION
OR INSTALLATION FOR THE REQUIRED SITE -SPECIFIC DESIGN.
I. ANY SCREEN ROOF ENCLOSURE THAT UTILIZES ROOF BEAMS THAT EXCEED 40-FEET IN SPAN, AT
ANY POINT ON THE ENCLOSURE.
2. ANY SCREEN ROOF ENCLOSURE THAT UTILIZES WALL COLUMNS (UPRIGHTS) THAT EXCEED 12-FEET
IN HEIGHT AT ANY POINT ON THE ENCLOSURE.
3. ANY ENCLOSURE THAT UTILIZES ANY CARRIER BEAM (A BEAM THAT ACTS AS SUPPORT FOR ANY
OTHER SCREEN ROOF BEAM) AT ANY PDINT ON THE ENCLOL5URE. NO CARRIER BEAM SHALL BE
PERMITTED TO BE MOUNTED TO THE FASCIA OF ANY HOST STRUCTURE (AS PRIMARY SUPPORT).
4. INSTALLATION OF ANY SCREEN ROOF ENCLOSURE ON AN EXISTING HOUSE FASCIA WHERE THE
OVERHANG EXCEEDS 2-FEET. NOTE THAT IF THE EXISTING RESIDENCE WAS CONSTRUCTED UNDER
ANY BUILDING CODE PRIOR TO F.B.C. 2001, THE JOB MAY REQUIRE FOURTH -WALL TYPE CONST, AS
THERE IS NO WAY TO CERTIFY THE ABILITY OF A HOST STRUCTURE THAT WAS ONLY BUILT TO WITH-
STAND IIG MPH WIND LOADS OR LESS, (AS WAS REQUIRED UNDER PREVIOUS BUILDING CODES) TO
RESIST THE IMPOSED LOADS OF AN ENCLOSURE THAT 15 DESIGNED TO WITHSTAND THE LOADS
IMPOSED UNDER THE 140 MPH WIND LOAD SPECIFIED IN THE CURRENT BUILDING CODE.
MINIMUM FOOTED T45LES
AX. BM.
OOPPEOTER
PAN
8 ° WITH
(IJ "54 T
TO 38'
8' X_UOM
CONT.
UP I'
10'x12'WITH
(1) K54 CONT.
UP TO 40'
U' x 12" WITH
�GENT
UP TO 55'
ISOLATED
MAX. BM.
FOOTER(-)
SPAN
12'x12'WIT4
(2) SO CONT,
UP TO 30'
12' x 16' WITH
(2) SO CONT.
31' TO 39'
14' x 16' WITH
(2) SO CONT.
40' TO 44'
16' x I6' WITH
44' TO 52'
(2) ISO CONT.
IF A JOB EXCEEDS THESE PARAMETERS, THE FOUNDATION
MUST RE SITE-5pECIFICALLY DESIGNED BY THE ENGINEER
MONOLITHIC FTG. LOAD CAPACITIES ARE BASED
ON A MIN, OF 3 FEET OF CONT. CONCRETE, 2,500 PSI
MINIMUM, W/ WIRE OR FIBI=RMESH REINFORCEMENT
()ISOLATED FOOTERS MAY BE USED
ON EDGE OF EXIST. CONC. SLAB
OR UNDERNEATH THE PERIMETER
OF BRICK PAVER DECK (ALL SIDES)
THE ENGINEER OF RECORD WILL NOT BE ABLE
TO CERTIFY THE STRUCTURAL INTEGRITY OF
ANY EXISTING CONCRETE DECK / FOOTINGS
THAT WERE INSTALLED WITHOUT PERMITS, AS
THERE WOULD BE NO RECORDS TO VERIFY
CONCRETE THICKNESS', FOOTER SIZES AND
THE SIZE AND QUANTITY OF STEEL RE -BARS
THAT WOULD BE REQUIRED UNDER THE
CURRENT BUILDING CODE STANDARDS.
SCREW SPACING AND EDGE DISTANCE SPEC.'S
THIS TABLE IS BASED ON THE PROPERTIES OF C-1022 LOW CARBON STEEL SMS
AND SELF -DRILLING (TICK) SCREWS, WHICH ARE AN INDUSTRY STANDARD SCREW.
SCREW SIZE
NOMINAL SCREW
DIAMETER (IN.)
MIN, EDGE
DISTANCE
MIN. CENTER -TO -
CENTER DISTANCE
08
#10
0,188
3/8'
1/2'
012
0.219
1/2'
5/8,
014
0.250
5/8'
3/4'
SNAP / LAP JOINT INTERNAL CONNECTION SPECIFICATION (UTILIZING SCREW 5065E5)
ALL INTERNAL CONNECTIONS UTILIZING THE EXTRUDED SCREW BOSSES SHALL HAVE:
CONNECTION NOTE: 010 SMS SCREWS, WITH A MINIMUM EMBEDMENT INTO THE SCREW 6055 OF 1 3/4" (UNLESS
A SSSN I
ALL FRAMING MEMBERS ON ANY
OTHERWISE SPECIFIED ON ANY CONNECTION DETAIL). LL SCREW PO E I A G VEN
ENCLOSURE THAT UTILIZE SNAP
EXTRUSION MUST BE FILLED (EXAMPLE: THE 2 x 3 x .010 CHAIR RAIL / ROOF PURLIN
OR LAP JOINT IN THEM SHALL _
_,_j� {AT HAS SIX SCREW BOSSES, MUST HAVE SIX OF THESE 010 5M6 SCREWS INSTALLED
HAVE 012 TEKS INSTALLED THRU
AT EACH END OF THAT COMPONENT, AT EACH CONNECTION).
THE SNAP OR LAP CONNECTION
AT IS INCHES ON CNTR. (TYP),
THESE TEK SCREWS ARE TO E3E
PLACED ON BOTH EDGES OF
SCREEN PANEL INSTALLATION SPECIFICATION.,
THE UPRIGHT (BOTH THE INNER
PLEASE NOTE THAT ALL SCREEN PANEL OPENINGS (BOTH ROOF AND
AND THE OUTER EDGE) IN ALL
WALLS) SHALL BE INSTALLED ON ALL FOUR SIDES WITH SPLINE (INDEP-
CASES. THIS SPECIFICATION
ENDANT OF ALL SURROUNDING PANELS). THE ONLY FRAMING COMPONENTS
APPLIES TO UPRIGHTS AND
THAT ARE NOT REQUIRED TO HAVE SPLINE INSTALLED IN THEM ARE ALL OF
BEAMS BOTH.
THE DIAGONAL WALL AND ROOF BRACING.
SIGN DISCLAIM
ALL CONCRETE ANCHOR5 SPECIFIED ON THIS DETAIL
SHEET ARE MANUFACTURED BY 'RED HEAD' ANCHORING
SYSTEMS, AS ALL LOAD CAPABILITIES ARE BASED ON
TEST DATA FURNISHED BY RED HEAD IN THEIR PRODUCT
AND RESOURCE BOOK. NO SUBSTITUTIONS OF ANY OTHER
MANUFACTURER'S CONCRETE ANCHOR5 15 PERMITTED
WITHOUT SUBMITTAL OF THE COMPANY'S TEST DATA (TO
VERIFY EQUIVALENT LOAD CAPACITIES) AND A WRITTEN,
SIGNED AND SEALED LETTER OF AUTHORIZATION FROM
THE ENGINEER OF RECORD. ANY UNAUTHORIZED ANCHOR
SUBSTITUTION SHALL BE DEEMED NON -COMPLIANT WITH-
TH15 DESIGN. THE ANCHORS TO BE USED FOR APPLICATIONS
SPECIFIED IN THIS ENGINEERING DESIGN PLAN ARE AS
FOLLOWS:
1/4' DIA FASTENERS:. RED HEAD ITW TAPCON (SEE INDIVIDUAL DETAILS
FOR MINIMUM EMBEDMENT DEPTH INTO CONCRETE)
3/8' DIA. FASTENERS: 3/8° TRU BOLT WEDGE ANCHOR (SEE INDIVIDUAL
DETAILS FOR QUANTITY OF FASTENERS NEEDED)
(MINIMUM EMBEDMENT 5HALL BE 3' INTO CONCRETE
UNLESS OTHERWISE SPECIFIED IN ANY DETAIL)
3/8' LARGE DIAMETER TAPCON (LDT) (BEE INDIVIDUAL
DETAILS FOR QUANTITY OF FASTENERS NEEDED)
(MINIMUM EMBEDMENT SHALL BE 21i2' INTO CONCRETE
UNLESS OTHERWISE SPECIFIED IN ANY DETAIL)
FOR BRICK PAVER INSTALLATION:
FOR INSTALLATION ON A BRICK PAVER DECK, THE ONLY FASTENERS THAT
WILL MEET THE DESIGN CRITERIA INDICATED WITHIN THESE DESIGN SPEC.'S
ARE THE RED HEAD TRU BOLT WEDGE ANCHOR (3/8' x I'), WHICH BASED
ON 1/8' ANGLE, I x 2 O.B., 211$' THICK BRICK PAVER AND A MAXIMUM MORTAR
BED THICKNESS OF 3/4'. THIS SCENARIO WILL STILL MEET THE MINIMUM
FASTENER EMBEDMENT. IF ANY OF THESE CONTRIBUTING FACTORS EXCEED
THE DIMENSIONAL BREAKDOWN INDICATED, THE JOB MUST BE PRESENTED
TO THE ENGINEER OF RECORD FOR SITE -SPECIFIC ANCHORING DESIGN.
EXIST. HOUSE FASCIA NOTES:
IT SHALL BE THE RESPONSIBILITY OF THE INSTALLING
CONTRACTOR TO IN5PECT AND INSURE THE CONDITION
OF THE EXISTING FASCIA, TO DETERMINE IF IT 15 IN GOOD
ENOUGH CONDITION TO SUPPORT THE PROPOSED SCREEN
ENCLOSURE (PRIOR TO ITS INSTALLATION)
THERE IS NO CERTIFICATION, EITHER EXPRESSE�OR IF1PLIkD lR THfS ERiSlNEERIKG-DESTGN-D-CCUMENT-
REGARDING THE ABILITY OF ANY HOST STRUCTURE TO RE515T THE BUILDING CODE SPECIFIED DESIGN
LOADS IMPOSED BY ANY PROPOSED SCREEN ENCLOSURE. SUCH CERTIFICATION WILL BE DEPENDENT
ON AVAILABILITY OF ORIGINAL DESIGN AND CONSTRUCTION DOCUMENTS, AS WELL AS ORIGINAL PERMIT
AND INSPECTION RECORDS FOR THE H05T STRUCTURE. CERTIFICATION OF THE HOST STRUCTURE, IF IT IS .
REQUIRED, WILL ULTIMATELY BE POSSIBLE ONLY IF THESE RECORDS CONTAIN ALL THE INFORMATION
NEEDED BY THE ENGINEER TO PERFORM ALL OF THE NECESSARY ANALYSIS TO DETERMINE IF SUCH
CERTIFICATION 15 EVEN POSSIBLE.
b>
t=
io ®®z
9��
c+�
U.
00 8wLul 8
acn~
aaw
�®.Zcz
oo ljL
LUZ®-®
�a�
�- Lu
� co LM
0cn
o
>�S3
Z !ggRa
�
LL;
cN
GENERAL NOTE5 AND IDE51GN PARAMETER&
I. THE OVERALL DESIGN COMPLIES WITH THE 200(o AMENDMENT TO THE FLORIDA BUILDING CODE 2004 (CHAPTER
• 16 AND 20), AND 15 BASED ON THE FOLLOWING PARAMETER5:
A. WIND SPEED: 140 M.P.N., 3-SECOND GUST
B. EXPOSURE CATEGORY 'B'
C. DESIGN PRESSURES AS FOLLOWS:
a) SIMULTANEOUS WIND LOADING 0 (b F.S.F. FOR SCREEN ROOF AND 21 P.5F. FOR SCREEN WALLS
b) 300 LB LOAD APPLIED VERTICALLY DOWNWARD ALONG ANY ONE FOOT (it -INCHES) OF ANY PRIMARY
MEMBER (EXCLUDING DIAGONAL WIND BRACING, WHICH 15 TREATED AS A 'STRUCTURAL MEMBER' UNDER
2006 AMENDMENT DEFINITIONS.
D. MAXIMUM ENCLOSURE HEIGHT SHALL NOT EXCEED 30-FEET
E. ALLOWABLE DEFLECTION OF 'L / 60% A5 SPECIFIED I TABLE p1610.1, FOR NON -HIGH VELOCITY HURRICANE
ZONES.
F. CONTINUOUS LOAD PATH IS PROVIDED,
2. MATERIALS (UNLESS OTHERWISE SPECIFIED BY THE ENGINEER OF RECORD):
A. ALL EXTRUSIONS SHALL BE ALUMINUM ALLOY 06063-T6 (NOTE THAT THE 5PLICE PLATE MATERIAL MAY
BE EXTRUDED FROM ALLOY 06061-T(o, 1F THIS MATERIAL 15 MORE READILY AVAILABLE TO THE
CONTRACTOR) (SEE COMPONENT SHAPES AND SIZES AT RIGHT).
B. FASTENERS SHALL BE ALUMINUM ALLOYS 2024-T4 t 1015-T(o, DOUBLE CAD -PLATED STEEL, HOT -DIPPED
GALVANIZED STEEL, OR 300-6ERIES STAINLESS STEEL. IT 15 THE RESPONSIBILITY OF THE CONTRACTOR TO
PROVIDE THE APPROPRIATE MEANS FOR SEPARATION OF DISSIMILAR MATERIALS AS THEY ARE DEFINED IN
SECTION �2003.8.4. THE CONTRACTOR MAY IMPLEMENT ANY OF THE MEANS SPECIFIED IN THIS SECTION. ANY
ALTERNATIVE MEANS MUST BE ACCOMPANIED BY A LETTER of CERTIFICATION FROM THE PRODUCT'S
MANUFACTURER (THIS LETTER MUST BE SIGNED AND SEALED BY A FLORIDA LICENSED STRUCTURAL ENGINEER),
WHICH STATES THAT THEIR PRODUCT MEETS / EXCEEDS ALL OF THE REQUIREMENTS SPECIFIED IN THE ABOVE -
LISTED SECTION. THI5 LETTER SHALL ALSO BE REVIEWED AND APPROVED BY THE ENGINEER OF RECORD
FROM B.D.Q., INC.
C. SCREEN CLOTH SHALL BE VINYL COATED, WOVEN FIBERGLASS, MAXIMUM DENSITY OF 18 x 14 158% OPEN).
3. ALL FASTENERS THAT PASS THROUGH ANY EXTRUSION INTO CONCRETE, MASONRY, WOOD, STEEL, ALUMINUM
OR ANOTHER EXTRU51ON SHALL HAVE A 5/6-INCH DIAMETER WASHER, MINIMUM (UNLESS OTHERWISE SPECIFIED
BY THE ENGINEER OF RECORD), AND SHALL BE NO MORE THAN 18-INCHES CENTER - TO - CENTER SPACING.
4. ALL FASTENERS ADJACENT TO UPRIGHTS THAT DO NOT REQUIRE REINFORCING ANGLE CLIPS, SHALL BE
PLACED WITHIN TWO (2) INCHES OF THAT UPRIGHT (TYP. FOR BOTH SIDES).
5. SCREEN DOOR(5) MAY BE LOCATED IN ANY SCREEN WALL PANEL, EXCEPT FOR THOSE THAT CONTAIN
DIAGONAL 'Wf",D BRACINa ('K-BRACING'). ALL DOCKS SHALL BE SELF -CLOSING AND SELF -LATCHING.
DOORS INSTALLED IN AN ENCLOSURE THAT SURROUNDS A POOL / SPA SHALL HAVE DOOR LATCHES
INSTALLED FIVE (5) FEET ABOVE THE FLOOR, MINIMUM.
6. COPIES OF THIS ENGINEERING SPECIFICATION / DESIGN DETAIL ARE TO ONLY BE CONSIDERED VALID
FOR PERMITTING OR DESIGN CERTIFICATION PURPOSES WHEN ALL SHEETS OF ANY SUBMITTED SET BEAR5
THE ENGNEER'S ORIGINAL SIGNATURE (IN BLUE INK), UNDER HIS EMBOSSED SEAL. S.D.Q., INC. SHALL NOT
BE RESPONSIBLE FOR NON -ORIGINAL COPIES THAT ARE SUBMITTED, THAT HAVE ANY UNAUTHORIZED
CHANGES, ALTERATIONS OR DELETIONS ON THEM.
1. THESE ENGINEERING DETAIL DRAWINGS ARE ONLY VALID IF THE DATE ACCOMPANYING THE ENGINEER'S
ORIGINAL SIGNATURE 15 LESS THAN 90 DAYS OLD. NO BUILDING OFFICIAL OR BUILDING DEPARTMENT
SHOULD ACCEPT COPIES THAT ARE OLDER THAN THIS, AND SHOULD REQUEST THE SUBMITTING CONTRACTOR
OBTAIN UPDATED / CURRENT ENGINEERING.
8. ALL ENGINEERING SPECIFICATIONS AND DETAIL DRAWING CONTAINED WITHIN THIS ENGINEERING DOCUMENT
ARE THE SOLE PROPERTY OF B.D.Q, INC. ANY UNAUTHORIZED COPYING OR OTHER REPRODUCTION IN PART
OR WHOLE OF THESE DOCUMENTS WILL NOT BE PERMITTED AND WILL BE PROSECUTED TO THE FULLEST
EXTENT ALLOWED BY LAW.
9. THERE SHALL BE NO REDISTRIBUTION OF THESE ENGINEERING DOCUMENTS BY THE PERSON OR COMPANY
THAT ORIGINALLY PURCHASED 516NED AND 5EALED COPIES FROM B.D.Q., INC., WITHOUT EXPRESS WRITTEN
AUTHORIZATION FROM B.D.Q., INC., AND THE ENGINEER OF RECORD.
Tf GOMPONENT ,5HAPE5 AND 5PEGIFIGATION5 093
Tw /qry .044 Ir .040
.010 � .Y/ 10
B
O
3' 2'
2'
2' I 3" 1 x 3 O.B. I x 2 0.5. 2 x 2 x .093 TUBE
2' 2 x 3 "H" 3 x 3 W DIAL. BRACING
THE ACTUAL VALUES FOR 'TP' (FLANG--E THICKNESS) AND 'Tw' (WEB THICKNESS) FOR THE VARIOUS
5ELF-MATING ("0 SIZE SELF -MATING MATERIAL ARE INDICATED ON THE TABLE BELOW.
w
d)
nc
HOST STRUCTURE WITH
OtIC STRUCTURAL GUTTER
MANSARD ROOF BEAM SPAN
Lu I' ANbAKL) Ft5kA" 1MAT NOT
EXCEED AN OVERALL_ ANGLE OF 30°
w
--I w
HOST STRUCTURE WIT
STRUCTURAL GUTTER
PEAK / GABLE ROOF BEAM SPAN
i
PEAK BEAM 5PL-ICES MAY NOT
A EXCEED AN OVERALL. ANGLE OF 30°
SIZE
DIMENSION
Tf
Tw
2xr4 L
A00
.045
2x5 L
.116
.050
20 L
A20
.050
2x7 L
A20
.057
24 L
.224
.072
9 L(L)
.209
.072
9 L (H)
f
AN
.032
A0 L
11/1GT GTt711l TI IOC' II IITI I
w
C)
W�z
co
�vwUJ
ca �
� .6
® 0 ILX,
>w Lam
U. o
® C) LU LU
jj®>
�Lue
cool ®;EWa ��
� � ca
_��
ti�
inu�
= .a�i28
off- _
zM��
W Z CL U_
0U 04
W
tcS
cs yj
LL
�L4
a
DESIGN NOTE: ALL THRU-BOLTS PASSING THROUGH ANY ALUMINUM
MATL. WITH A WALL THICKNESS LESS THAN 030, SHALL HAVE A 1'i8-INCH
(OUTSIDE DIA.) FENDER WASHER l5EE GENERAL NOTE "2 ON SHEET #2
REGARDING SEPARATION OF 01651MILAR METALS).
THE CONTRACTORS MAY, IF THEY CHOOSE, INSTALL THE ANGLE CLIPS
FOR THE DIAGONAL TUBE BRACING (WHERE IT ATTACHES TO THE SELF -
MATING SCREEN ROOF BEAMS) WITH THE THRU-BOLTS ONLY PASSING
THROUGH ONE HALF OF THE BEAM. THIS 15 A STRUCTURALLY ADEQUATE
ALTERNATIVE, AND WILL PERMIT INSTALLATION OF THESE ANGLE CLIPS
IN THEIR SHOP, DURING FABRICATION (POSSIBLY SAVING TIME DURING
INSTALLATION IN THE FIELD).
NOTE:
ALL DIAGONAL BRACING SHALL BE ATTACHED
VIA THE 2 x 2 x lia" ANGLE CLIPS, AS SHOWN,
AND SHALL HAVE EACH END ATTACHED TO
EITHER THE SCREEN ROOF BEAM OR TO THE
EVE RAIL. NO DIAGONAL BRACING SHALL- BE
ATTACHED TO ANY OF THE ROOF PURLINS
DESIGN NOTES:
ALL DIAGONAL BRACING, USED EITHER IN THE ROOF,
OR AS 'K'-BRACING IN THE WALLS SHALL BE 2" x 2'
x .093 WALL THICKNESS TUBE, AND SHALL BE CUT TO
FIT SNUG,_WITH NO PLAY OR SHIFT IN THE BRACING.
SEE DETAILS AT RIGHT FOR CONNECTION SPECIFICATIONS
X
UPPER ANGLE CLIP TO BE PLACED
AT SAME ANGLE AS THE MANSARD
LEG OF THE SCREEN ROOF BEAM
2x3x.01®EVE RAIL
2 x 2 x pia' ANGLE CLIP, CUT
AT A 45' (+!-) ANGLE AND
ATTACHED TO THE 2 x 3 x
.010 EVE RAIL WITH ONE (U
1/¢' DIA. THIRd-BOLT, WITH
FENDER WASI4ER (SEE
DESIGN NOTE ABOVE
2 x 3 x .010 SCREEN
ROOF PURLIN
x
N
2 x 3 x .010 SCREEN
ROOF PURLIN 2 x SMB SCREEN ROOF
BEAM (TYP)
SPLICE JOINT
2 x 2 x '/a' ANGLE CLIP, CUT
AT A 45' bl-) ANGLE AND
ATTACHED TO THE SCREEN
- - ROOF BEAM WITH ONE (1)
114' DIA. THRU-BOLT, WITH
® FENDER WASHER (SEE
DESIGN NOTE ABOVE
2 x 2 x -.093 DIAGONAL ROOF BRACE, CUT
AT 45' ANGLE (+/-) AT EACH END AND
ATTACHED TO EACH ANGLE CLIP WITH A
1/4' DIA. THRU-BOLT, AS SHOWN
TYPICAL ANGLE ARTICULATION
TO CREATE UPWARD ANGLE
[DIAGONAL ROOF 5RACING DETAIL
O
ul
. I
L
i9
W
5 way.
gn
uj
�> F—A.
M. J - co %oix
��:�
LU
0) a
-� W
r o• w
u:
o to
� lu
0�.
cv
4-w
cn-
GE 5PECIFICATION5
a'
el
TEK SCREW
pICAL) SAME
JUST
3� o
0 1
° o a 0 o
® o o ° 1
\
1 0 0 ° a 3x;
1 0 o c o® C
1® ° o OF
l0 0
° i
__
EEN
PURLIN ROOF BEAM
COPY
�
---I x 2 Oa TOP
'A' BELOW, SCREEN FRAME
VERSED
2 x 2 x .093 TUBE
DIAGONAL BRACE
.010 H
2 UPRIGHT
SPLICE PLATE MATERIAL
1 SHALL RE 1/4' THICK (MIN.)
AND RE EITHER 06063-T6
OR 06061-T6 ALLOY
SEAM 5FL_ICE DETAIL. (2 x 8 IBEAMS AND LARGE "All
E
®110-1 0 �N
° 0 ° O V 4-INCH x 4-INCH x
1 0 1 a .010 PLATE, WITH
11 0 0 ° o C (4) 012 TEKS IN THE
1 0 3 x 3,(3) 012 TEK5
° SPLICE PLATE MATERIAL. IN THE BOTTOM I
z O\QI\A SHALL BE 3/16' THICK (MIN.) x 2TAND
HE 2 (32 BRAC)
t2' 101ALp AND RE EITHER %063-T6 IN
OR 06061-T6 ALLOY
E3EAM SPLICE DETAIL. (2 x I 15EAM5 AND SMAL-L_ER)
-O
TYP. F
BEAM
TYPICAL 3/16'OR 1/4' THICK
SPLICE PLATE
3x3°H•,,..��
COLUMN
2x2xOrJ3TI
SPLICE PLATE TOLEF:ANCE NOTE; - - DIAGONAL BF
ALL 5PLICE PLATES (ALUMINUM I x 2 BOTTOM
ALLOY 06063-T(b or 06061-T6) SCREEN FRAt-
SHALL BE CUT TO E,E +0.000 /
-0,0625, AS INDICATED IN THE
SCHEMATIC DRAWING AT LEFT
2x3x910CHAIR
RAIL
2 x 2 x ,055 TUBE -
DIAGONAL BRACE
DETAIL. nA,l
(OUT61DE)
(INSIDE)
I
I x 2 05 BOTTOM
SCREEN FRAME
c 3 'H' GOF 41zN
)LUMN
2 x 2 x .093 TUBE
DIAGONAL BRACE
I x 2 BOTTOM
SCREEN FRAME
I -INCH x 3-INCH x
,093 ANGLE, CUT 4-
INCHES LONG, _WIT H
(3) 12 TEKS IN THE
3 x 3, (3) *12 TEKS
IN THE BOTTOM I
x 2 AND (3) 012 TEKS
IN THE 2 x 2 BRACE
2 x SMB UPRIGHT
2 x 2 x .OS3 TUBE
DIAGONAL BRACE
0 O
2x3x910 0 0
v
CHAIR RAIL o
0 0 0 0
o
2 x 2 x .093 TUBE o° 0
DIAGONAL BRACE 0 0
2 x 5 5MB UPRIGHT
(MINIMUM SIZE) (OUT51DE)
2 x 2 x .093 TUBE -
DIAGONAL BRACE
2 x 5 5MB UPRIGHT o
(MINIMUM SIZE) o
0
2 x 3 x .010
CHAIR RAIL
\ I 1
2 x 2 x .093 TUBE -
DfAGONAL BRACE
(INSIDE)
is
® ill ®�
uj
4-fNCH x 10-INCH x ;
.010 PLATE, WITH (1)
412 TEK5 IN THE SMB
UPRIGHT, (3) 12 TEKS C) L
LLJ
IN THE CHAIR RAIL
AND (3) 012 TEKS IN
EACH 2 x 2 BRACE
2x3x,010
CHAIR RAIL
cK9.J_
r
0- U.
LJJ
® Lu
m�
0�
/—I-INCH x 3-INCH x
0
_
.093 ANGLE, CUT 4-
INCHES LONG, WITH
(3) 012 TEKS IN THE
5M5 UPRIGHT AND
(3) 012 TEKS IN THE
2 x 2 BRACE
2x3x.010
CHAIR RAIL
>,
�— I -INCH x 3-INCH x
'~
- -.093 ANGLE, CUT 4-
INCHES LONG, WITH
(3) BIZ TEK5 IN THE
w
>y �-
5MB UPRIGHT AND
(3) 012 TEK5 IN THE
2 x 2 BRACE
® tad g
�m�; ti
5GIREEN IR00F ENCLOSURE-TO-HOF STRUCTURE ATTACHMENT DETAI
DESIGN NOTE: THE 3-INCH LEG OF THE ANGLE SHALL BE
PLACED AGAINST THE I x 2. THIS ALLOWS A MIN. EDGE
D15TANCE FOR THE FASTENERS (FROM THE EDGE OF THE
ANGLE) OF ONE -INCH, AND MAINTAINS A SIX-INCH MIN.
CENTER -TO -CENTER DISTANCE FOR THE MAX. SIZED
CONCRETE ANCHORS (3/8" x 31/29
CAP ITYP)
HOST C.B.S. WALL (TYP)
TYP SCREEN ROOF BEAM
I x 2
2' x 3' x .125' ANGLE W/ (4) 012
TEKS, TYP, EACH 51DE OF BEAM
FA5CIA REINFORCEMENT IDE61GN NOTE:
ALL FASCIA BOARDS ON ANY EXISTING HOST STRUCTURE THAT WILL HAVE
ANY PART OF THE PROPOSED SCREEN ENCLOSURE ATTACHED TO IT SHALT_
BE REINFORCED, BY PLACING ONE (1) 1/4' x 4' LAG SCREW INTO THE END OF
EVERY TRUSS TAIL (WHERE THE PROPOSED SCREEN ENCL06URE IS BEING
INSTALLED). THESE TRUSS TAILS MUST BE PILOT DRILLED WITH A 5/32" DRILL
BIT TO PREVENT SPLITTING THE END OF THE TRUSS TAILS. IT. SHALL BE THE
REP6ON5181LITY OF THE INSTALLING CONTRACTOR TO ENSURE THAT THIS STEP
IS COMPLETED, AS SPECIFIED, PRIOR TO ANY INSTALLATION TAKING PLACE.
FASTENER SHALL BE 1/4' x 3 1/2'
RED -HEAD ITW TAPCON FOR ALL
2' x 6' BEAMS AND SMALLER. FASTENERS
SHALL BE 3/0' DIA, FOR 2' x 1' BEAMS
AND LANCER (SEE DESIGN NOTE ABOVE
REGARDING 3/6 FASTENER SPACING)
WALL ATTACHMENT
F45CIA REINFORCEMENT
5FECIFICATION5
1/4' x 4' LAG SCREW, TO
BE INSTALLED INTO THE
END OF EVERY TRUSS
TAIL WHERE A SCREEN
ENCLOSURE WILL BE
ATTACHED. THE T%55
TAIL SHALL BE PILOT -
DRILLED WITH A 5/32'
DRILL BIT (TO PRIEVEN'
SPLITTING THE END OF
THE TRUSS TAIL)
10-INCH LONG 025 THICK) EXTRUDED
SEE 'SNAP / LAP CONNECTION'
'z' GUTTER INSERT, TYP CENTERED ON
NOTE ON SHEET I FOR SPEC.'S
EACH ROOF BEAM, WITH FOUR (4) 010
TEKS THRU TOP LIP OF GUTTER
.Q
2 x 3 x .125 ANGLE CLIP
(CUT 2' LONG-) W/ 3-INCH
1/4' x 21/4' LAG5, FOUR (4)
LEG AGAINST I x 2. CLIP
IN EACH 10-INCH INSERT
° SHALL HAVE FOUR (4) #12
AND AT 24' O.G. (MAX. N
TFKS INTO SIDE OF ROOF
SPACING) IN THE REST
0 BEAM AND TWO (2) 014 x
OF THE GUTTER (PILOT - -�
2' TEKS (PER ANGLE CLIP)
DRILL FASCIA W/ 5/32" N
THRU GUTTER AND INTO 7'
BIT TO AVOID SPLITTING)
GUTTER INSERT (TYP. ONE
N
ANGLE CLIP ON EACH SIDE
OF EACH BEAM)
TYP. 2 x SCREEN ROOF
BEAM (MAY BE FLAT
5' STRUCTURAL
I x 2 SCREEN OR SLOPED)
GUTTER (CONT.)
FRAME (TYP)
FLAN VIEW
TRUSS TAIL (TYP/
CAP (TYP)
2 x FASCIA
BOARD (TYP)
t
NOTE: FASCIA ATTACHMENT REQUIRES A 2 x FASCIA
BOARD (MINIMUM). A 'I x' FASCIA 15 ONLY ADEQUATE
FOR THIS INSTALLATION WHEN THERE IS A 2 x SUB -
FASCIA BEHIND IT, IN THIS CASE, THE LAGS MUST
PENETRATE THE SUB -FASCIA 11/2' (MIN. EMBEDMENT).
IT SHALL BE THE RESPONSIBILITY OF THE SCREEN
CONTRACTOR TO VERIFY THE PRESENCE OF THIS
5U5-FASCIA.
10-1 LONG 025 THICK) EXTRUDED -
'ZYtUTTER INSERT, TYP CENTERED ON
ACH ROOF BEAM, WITH FOUR (4) 010
TEKS THRU TOP LIP OF GUTTER
r 2 x HOUSE FASCIA
(SEE FASCIA NOTE
ABOVE)
1/4' x 21/4' LAG5, FOUR (4) ----�
IN EACH 10-INCH INSERT
AND 24" O.C. (MAX,RES
SPACININ G) IN THE REST
OF THE GUTTER (PILOT
DRILL FASCIA W/ 5/32'
BIT TO AVOID SPLITTING)
- I x-2-x-.093 ANGLE SPACER-
(FOR ANGLED FASCIA BD.
ATTACHMENT), ATTACHED
W/ TWO (2) ROWS OF 010 TEKS
STAGGERED), EACH ROW AT
O,C. (MAX, SPACING)
STRUCTURAL GUTTER CONNECTION
TYP SCREEN ROOF BEAM
I x 2
2' x 2' x .125' ANGLE W/ (4) 012
TEKS, TYP, EACH 51DE OF SEAM
1/4' x 2 1/2' LAG SCREW TYP. I
EACH SIDE OF BEAM (2' x (b' BEAMS
AND SMALLER) 3/6' x 2 1/2' LAG
SCREW (2' x l' REAMS AND LARGER)
FA5C I A ATTACHMENT
ENE
RE
a
SEE "SNAP / LAP CONNECTION'
NOTE ON SHEET I FOR 6PEC,'5
'---U-CHANNEL
CAP (TYP)
I x 2 SCREEN
FRAME (TYP)
5' STRUCTURAL
GUTTER (CON T .)
5ECTION VIEW
TYP. 2 x SCREEN ROOF
BEAM (MAY BE FLAT
OR SLOPED)
2 x 3 x.125 ANGLE CLIP
(CUT 2' LONG) W/ 3-INCH
LEG AGAINST I x 2. CLIP
SHALL HAVE FOUR (4) 012
TEKS INTO SIDE OF ROOF
BEAM AND TWO (2) 014 x
2' TEKS (PER ANGLE CLIP)
THRU.-GUTTER AND INTO T_
GUTTER INSERT (TYP. ONE
ANGLE CLIP ON EACH SIDE
OF EACH BEAM)
CL
o
E
. J `
FRONT WALL
2 x 2 x 3/16' ANGLE, WITH FOUR
(4) 012 TEKS INTO THE UPRIGHT
I x 2 OB BOTTOM FRAME
AND ONE (1) 3/8' RED -HEAD
,
'TRU-50LT' WEDGE ANCHOR
2 3/4°,MIN. EDGE
(MIN. OF 4-INCH EMBEDMENT
INTO THE CONCRETE)
DISTANCE
�k 33 x .010 FRONT WALL
SIDE WALL
., ORNER UPRIGHT
010 x 2' SMS SCREW, WITH 5/8'
DIA. WASHER (6EE GENERAL
I x 2 Op BOTTOM FRAME
ui
z
X
NOTE 03, SHEET N2) TO BE 18-
INCHES, CENTER -TO -CENTER
I x 3 05 SIDE -WALL CORNER
?
MAX. SPACING
UPRIGHT
CY
PL14N
VIEW
MANSARD SCREEN ROOF
2 x 3 x .010 EVE RAIL,
REAM(BEYOND)
TYP. (CONTINUOUS)
2 x 5 x /e' ANGLE (2-INCHE5
LONG) WITH (2) 014 TEKS INTO
TOP OF 2 x 3 EVE RAIL AND
(2) 014 TEKS INTO THE FRONT
I x 2 OB TOP FRAME
OF THE 3 x 3 H FRONT WALL
CORNER UPRIGHT
I x 3 05 SIDE -WALL CORNER
UPRIGHT
_
010 x 2' SMS SCREW, WITH 5/8'
DIA. WASHER (SEE GENERAL
NOTE 03, SHEET 02) TO BE IS -
INCHES, CENTER -TO -CENTER
3 x 3 x .010 FRONT WALL
MAX. SPACING
CORNER UPRIGHT ,
2 x 2 x 3/16' ANGLE, WITH FOUR
(4) 012 TEKS INTO THE UPRIGHT
AND ONE (1) 3/8' RED -HEAD
'TRU-BOLT' WEDGE ANCHOR
2 3%', MI . DGE
(MIN. OF 4-INCH EMBEDMENT
DIS CE
INTO THE CONCRETE)
0 0
I x 2 OB BOTTOM FRAME
ELEVATION VIEW
-_- CORNER-UP-RIHT-[DETAIL
NOTE: THIS ATTACHMENT
I x 2 0,5. SCREEN FRAME,
DETAIL ALSO APPLIES TO
TYP. BETWEEN UPRIGHTS
A 2 x 2 SCREEN FRAME,
OR AS FRIGHTS AGAINST
W/ THE FASTENER SEINE
A W OR COLUMN
4' IN LENGTH, TO
I/ ' IA, x 31/4' TAPCON
MAINTAIN A 2' MIN.
EE PLACED AT NO MORE
EMBED,
HAN 18' O.G. (RE: GEN. NOTE 03)
MIN. EMBEDMENT FOR
CONC. / C.5.6. / MASONRY
ALL TAPCONS SHALL
SURFACE
BE 2' INTO CONCRETE.
NOTE: ALL FASTENERS 516ECIFIED IN 'COLUM-TO-FOUNDATION' DETAILS
PERTAIN ONLY TO THE FASTENERS TO 5E PLACED ON EITHER SIDE
OF COLUMNS, THIS DETAIL IS FOR ALL INTERMEDIATE FASTENERS FOR
I x 2 SCREEN FRAME TO EITHER CONC. DECK OR C.B.S. MASONRY WALL.
2 x 3 x .010 ROOF PURLIN
2 x 5 X.010 EVE RAIL,
TYP. (CONTINUOUS)
2 x 5 x /a' ANGLE (2-INCHES
LONG) WITH (2) 114 TEKS INTO
TOP OF 2 x 3 EVE RAIL AND
(2) 014 TEK6 INTO THE FRONT
OF THE 2 x SM5 SIDE WALL
UPRIGHT
I x 2 O5 TOP FRAME
010 x 2' SMS SCREW, WITH 5/8'
DIA. WASHER (SEE GENERAL
NOTE 03, SHEET 02) TO BE IS -
INCHES, CENTER -TO -CENTER
MAX. SPACING
2 x 5 SMB UPRIGHT (MINIMUM
SIZE FOR ANY UPRIGHT ON A
SCREEN ROOF ENCLOSURE)
234' MIN. EDGE
DISTANCE
SEE 'MINIMUM FOOTER —�
TABLES° -ON SHEET 0I-
0
0
0
21/a' x 11/2' U-CHANNEL CLIP
ATTACHED TO THE EVE RAIL
WITH SIX (6) 012 TEKS, AND (3)
012 TEKS INTO EACH 61DE OF
THE 2 x 3 ROOF PURLIN (TO
BE ATTACHED ON THE TOP
END TO THE SCREEN ROOF
BEAM IN THE SAME MANNER
2 x 4 x /9' ANGLE (2-INCHES
LONG) WITH (2) "14 TEK6 INTO
BOTTOM OF THE 2 x 3 PURLIN
AND (2) 014 TEKS INTO THE
SACK OF THE 2 x SM5 SIDE
WALL UPRIGHT
2 x 3 x .010 CHAIR RAIL (TYP)
2 x 2 x 3116' ANGLE, WITH FOUR
(4) 012 TEKS INTO THE UPRIGHT
AND ONE (I) 3/0' RED -HEAD
°TRU-BOLT' WEDGE ANCHOR
(MIN. OF 4-INCH EMBEDMENT
INTO THE CONCRETE)
I x 2 OB 50TTOM
6I[DE WALL UPRIGHT DETAIL
a �,s
5r� w
BEAM SIZE
2x5-2x(o
2x7-2x8
2 x 9
2x10___�
2 x SMB SCREEN ROOF BEAM
2 x 3 x ,010 ROOF PURLIN
NO, OF 014 TEKS
_ (PER 51DE)
(2) 014 TEKS
(4) 114 TEKS
(5) 014 TEKS
(6) 014 TEKS
0 0�
2 x 5 x'%' ANGLE l2-INCHES —,//)
LONG) WITH (2) 014 TEK6 INTO 0 01
TOP OF 2 x 6MB SEAM AND
(2) 014 TEKS INTO THE FRONT 0 0 l
OF THE 2 x SMB FRONT WALL
UPRIGHT
I x 2 05 TOP FRAME -' 1
#10 x 2' SMS SCREW, WITH 5/8'
DIA. WASHER (SEE GENERAL
NOTE a3, SHEET #2) TO BE 18-
INCHES, CENTER -TO -CENTER
MAX. SPACING
2 x 5 SMB UPRIGNT (MINIMUM
SIZE FOR ANY UPRIGHT ON A
SCREEN ROOF ENCLOSURE)
SCREEN ROOF BEAM SHALL
OVERLAP ON THE OUTER SIDE
OF BOTH SIDES OT THE UPRIGHT
(TYP. EACH BEAM -TO -UPRIGHT
CONNECTION) SEE TABLE ABOVE
FOR NUMBER OF 114 MKS, AS
SPECIFIED BASED ON BEAM SIZE
2 x 3 x .010 CHAIR RAIL (TYP)
2 x 2 x 3/I6' ANGLE, WITH FOUR
(4) 012 TEKS INTO THE UPRIGHT
AND ONE (1) 3/8' RED -HEAD
°TRU-BOLT° WEDGE ANCHOR
(MIN. OF 4-INCH EMBEDMENT
INTO THE CONCRETE)
23/4' MIN, EDGE
DISTANCE 0 0
1 x 2 OB BOTTOM FRAME 0 0
SEE 'MINIMUM FOOTER
--TABLES' ON SHEET 11 -- - - -
33/4' 3'
MIN. MIN,
FRONT WALL UPRIGHT [DETAIL
as s;