HomeMy WebLinkAboutSUBMITTED PAPERSPermit Number:
St. Lucie County.
h Building & Zoning Department v .
2300 Virginia Avenue
•'c( R1� . Fort Pierce, FL 34982 ScA jViv
772-462-1553 E3Y E®
APPLI.CATION FOR STORM SHUTTER PERMIT �►�
SEE REVERSE SIDE FOR INSTRUCTIONS DATE:
1. LOCATION%SITE ADDRESS: _ .3 �'S 30 /U A-10 4401 614,erc-e /Z. .s-f 9 9
2. PARCEL ID NUMBER: _ VU3 —8d ,5- Of/3 " Cby O
SECT �� TWP 1 (3 RNG lq6& MAP 1141( ZNG Iffiol LU I
y/ INIT
3. DESCRIPTION OF PROJECT OR WORK AC IVITY: A 5-1-GUlL hLr, rri CCL10-I1e-- .5 e
o .
4. TYPE OF STRUCTURE: SFR Addition OTHER //7 lo��
5. OWNER INFORMATION ,,I 6. CONTRACTOR INFORMATION
Name: e%e0Cge--i'%%10, en,,e1 /y(,66,5 FL Reg/Cert#: 1
Address: 5 /V 1q I R i County Cert #: I (Q 57^a
City: F • � i 2 ri { State: Z Business Name:
Zip:,3I-1'94q Phone:
Type of Surface attachment: Wood Frame Concrete .- Masonry—.� Other
Product
Minimum Design Pressure
Product Compliance
Report #
Method of Attachment.
As per 1707.4.4.1 FBC
Type
120 mph
130 mph
140 mph
140 Exp. C
SBCCI
Dade
Other"
Anchor Ty' pe
Anchor Spacing
Impact Glazing
Removable Panels
Accordion
L
"—,Sc-h A ke,
. e-
oll U
Colonials
Other
ALL PRODUCTS SHALL BE LABLED SBCCI OR DADE COUNTY FOR DETERMINING IMPACT RESISTANCE FROM
WIND BORNE DEBRIS. **SEE FINAL INSPECTION PROCEDURE FOR EXISTING RESIDENTIAL
�jSTRUCTURES ON BACK.
7. VALUE OF CONSTRUCTION: $ /q��� �` �' FEES DUE:: -1 56 6a
RECEIPT:
OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all wo will be done in
compliance with all applicable laws regulating construction and zping7�1
PRINT QUALIFIERS/OWNE S NAM
STATE OF FLORIDA, COUNTY OF M
ACKNOWLEDGED BEFORE ME THIS DAY OF , 2(1;�, BY,
OR WHO HAS PRODUCED TIFIC TION.
T
SIGNATURE OF NOTARY
TITLE: NOTARY PUBLIC
1 XJM C4.4--V t j Pam n IS PERSONALLY KNOWN TO ME
L�
TYPE OR PRINT NAME NOTARY
COMMISSION NUMBER �Qa a
NOTICE TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU
INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
,ov Ashley Danielle Revels
? � My Commission DD297090
J Expires March 07, 2008
. . 'Property Appraiser - St.Lucie Cc, `y, FL , ` Page 1 of 1
Michael Nafash Record: 1 of 1
Property Identification
Site Address: 3880 N A1A
Sec/Town/Range: 23 :34S :40E
Map ID: 14/23S
Zoning:
Ownership and Mailing
Owner: Michael Nafash Lisa Nafash
Address: 82 Alize Dr
Kinnelon NJ 07405
PROPERTY RECORD CARD
«Prey Next>> Spec.Assmnt Taxes Exemptions Permits Home Print
ParcellD: 1423-805-0113-000-8
Account#: 141847 y
Land Use: Condo A
City/Cnty: ST. LUCIE COUNTY
Legal Description
HIBISCUS -BY -THE SEA CONDOMINIUM BLDG 2 UNIT PH-1(OR
1751-2036)
Sales Information
Assessment TRIM
Total Land and Building
Date Price Code
Deed Book/Page
2007 TRIM:
573000
Land Value: 0 Acres: 0
6/24/2003 442500 00
WD 1751 / 2036
Assessed:
573000
Building Value: 573000
8/11/1999 299900 00
WD 1242 / 2892
Ag.Credit:
0
Finished Area: 2151 SgFt
1/1/1900 0
/
Exempt:
0
Taxable:
573000
Proposed Tax:
10822.19
BUILDING INFORMATION
Exterior Features
3900
View:
Ocean
RoofCover:
-
RoofStruct: -
View
ExtType:
X057 - HBTSecConB12 YearBit:
1999
Frame: -
Grade:
UD - UD
EffYrBlt:
1999
PrimeWaii: -
StoryHght:
0010 - 1 Story
No.Units:
1
SecWall: -
Interior Features
BedRooms:
3
Electric:
-
PrmintWall: -
FullBath:
2
HeatType:
-
AvgHt/FI:
112Bath:
0
HeatFuel:
-
Prm.Flors: -
%A!C:
0
%Heated:
0
%Sprinkled: 0
Special Features and Yard Items
Land Information
Type Y/S
Qty, Units Qual.
Cond. YrBit.
No. Land Use
Type Measure Depth
1 0400-Condo
115 -Unit 1
THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED.
http://www.pasle.org/prc.asp?prclid=142380501130008 9/26/2007
01-08-08;11:37AM;EXPERT SHUTTERS
772 871 0990 # 2/ 3
r •. ray aa. r, ��r � v+. • / v+...urr� � ` our rrr varrr •rvva�,,. va-ara�r vv v...... �'-�`_�•:-` -
EILE # 3153903._. OR.BQOK _ lr PAGE ~2334, Recorded 01/08/200E, 1110:07 AM"
The artd=J ed hero V
by wing i ibrm that improvement 4U be rondo to Cettaln W prnpetty, and in saaotdeaae with Cheptar 713,
FloddaStndte:r the following information is pr4vidad inthallodoe C�CCAtmenoeman4
1, nSS't�'r[Ort oaPxol�•z7r (isgti! desodption wtd atreot address, [f aYalla6tn) rAxsor�o NUA>g&[t; ^ O!i—t�Ov--B
saantvrstore �'Ji,�uStJ�� b� may}, sr®, ny�� 7AT ie� .
�� , y;s. •a �.....ti
3. dWl!r==0RrdAUorr; aN by f„. r. _ �.s•'•
'L N= maWd=of£aoshpledddoldir(lfattVdnOvmr)•,-
4,._-,-
_,•�
5. SUx$IY'S NAsda,AnD8k5gAND PEOttt; NUtd$aiATID 88ND AMOaNP! c-� r -: . r . f
6. rZMbRISNAM ADDMMAMMNXNQS= :
S dOA w3 (1 the Stets: of di& sma timtgmted by Owner ttpgss whom OotoCeS or ad= doottmeoft mgy be U=Cd sa provided by= ; t�
5eedon 713.13 (1) (a) 7., Flgrida Stanzeesr � ;,, .-� ;. �
NANNA. ADDRM AND PEONBNMd=- •CL
�-
V
S. In addltfon ZD hitaself Or herseii: Owner deal she 4
719.13 (I) (b).Florida 3tabdms i foifawing to °Mt`�'T
a Notice as ptvv{ded.kf.S6&6nNA1118,ADDIUSAMMONa • ^ �� !_ s
s Fa ed); n dam Ot'aotioa of r-0tataenceaee# (the acpisatiea slates is 1 year t to dra data of roaord(ng tutlete a dli mnntedala�is t" m
spacffied}' , 20 em
DMORTHEN
C of r r OPARMLmeaud ravideftntory10TRIdO ee wner's Aothotixed piIIeer/DiraCtorn'orinerlllfrrnager `
SureofFlorida
Cotmtyof '*' Lucia
The foregoing iostrtuttont was eCimawiedged before m4 this, day, of —hem 20oi By as
-For 0— ofperbgr� (t)'DC oPattthCcisy,...o.g. OMCW, Mmuo- attomry in feat)
(baron Of pony an bohalf ofwhom irm u entwes ttxecated)
_ Parsonally known or—, — pmdamd the following hypo of fdturtiBCtttion;
PYIrYc7:.Y �- ^�Ya+nINNRewta � -
S1't I C=Mb*n M297000 (31 ofNottiryPublie)
a EON A4ft 07,20M
Under Penalties of perjury, I d 0km that r have read tho foregoing and'that the feats In ii tree tote to the but of my lmovtledgc so d
bolle£(Secdan 92-W, Fiodda Stetutm),
3ipawre(s) nsr(s) ar 0-cr(a)' Attu►orized 0Mced)31rtMr/Parmwfi60 tAaerwhe Signed abova
)3y 13Y
Rw.usaym �Rac
d
Code Compliance Division
' 2300 Virginia Avenue
Ft. Pierce, FL 34982 Fees/Payments
Phone: (772) 462-1553 Fax: (772)
462-2522
Address 3880 N A1A 1201 Owner(s) Michael Nafash��
City / State / Zip I FPR IFL I
Unit #
Parcel# 1423-805-0113-000/8 Jurisdiction CTY Zoning 'HIRD _ot#
suture Land Use IResidential Medium Subdivision .` 1423805 Block �.
APPLICATION•- e
Permit Type . Storm Shutter
0709 0356 application Type Over the Counter Permit Other
j Issued Activity Type^ Stories pI itomatic Sprinkler System? Q
Pay Fee
Code Type •;• Account •;< Quantity Amount Date PostedPaid?' Now?
BIMS651
06-BIMS
491 2415 322050 200
$5.00
10/03/2007
BIMS651
06-BIMS
4912415 322050 200
$5.00
10/03/2007
Permi762'
06-Permit Fee - Storm. Shutter (1 & 2
491 2415 322000 200
$75.00
10/03/2007
PianR838
06-Plan Review - OTC Permits (One
4912415 322000 200
$75.00
10/03/2007
Yes
Yes -
Yes
Date Entered 09/27/2007
Date Paid 10/03/2007
Entered By[spells,
Historical? No
:Receipt #= Amount
Date Posted
0000057914
$155.00
10/03/2007
Paid By
EXPERT SHUTTER SERVICES INC •;+
Payment Type
CK •,•
Check (CK), Cash (CA),
Check #
18777
Mastercard (MC), Visa (VS), Fee
174---7
Waived (FW)„ Refund (RF),
Credit
Card Number
Reversal (RV)
3redit Card Authorization
1
Issued To
EXPERT SHUTTER SERVICES
Received By
gersteml
Date Paid
10/03/2007
..
$ 155.00
To refresh the balance, please click the
i
i
i
I
'Refresh Data' button at the top of the form
X y
Code Compliance Division
2300 Virginia Avenue
Ft. Pierce, FL 34982
Phone: (772) 462-1553 Fax: (772) 462-2522
http://stiucleco.gov/ce
Date: 03 October 2007
Job Address: 3880 N MA 1201
Received By: gersteml
Paid With: CK
Paid By: EXPERT SHUTTER SERVICES INC
Building
Receipt
Sign:
Receipt M
0000057914
'ermit Number:
SLC- 0709-0356
Amount:
$155.00
redit Card Number:
Check Number:
18777
� K
Code Compliance Division
2300 Virginia Avenue
Ft. Pierce, FL 34982
Phone: (772) 462-1563 Fax: (772) 462-1148
http://stiucieco.gov/ce
BUILDING PERMIT
Issued: 10/03/2007 Conf #; 581 Permit #: SLC- 0709-0356
Job Location: 3880 N Al 1201 City: FORT PIERCE
Permit Type: Storm Shutter
Job Description: INSTALLATION OF HURRICANE SHUTTERS ON (2) OPENINGS.
Subdiv: Hibiscus by the Sea Condominium
Lot: Block: Parcel: 1423-805-0113-000/8
Setbacks Left: Right:
Number of Units: 1.00 Floors: 1
Minimum Floor Elevation:
Job Value: $ 4,254.00
Front: Rear: Zoning: HIRD
Buildings: 1 Square Footage: 0.00
Flood Map: Flood Zone: Elev:
Page 1
Permit holder acknowledges through acceptance of this permit that separate permits must be obtained as required by the Florida Building Code
including those for all electric, plumbing, mechanical, roofing, and structural work. Further, he/she acknowledges responsibility to comply with all
requirements of the 2004 Florida Building Code.
NOTICE: In addition to the requirements in this permit, there may be additional restrictions applicable to this property that may be found in the
records of this County, and there may be additional permits required from other governmental entities such as water management districts, state
agencies, or federal agencies. s:553.79(10), F.S.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR
BUILDING IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. s.713.135, F.S.
Christopher Lestrange
Building Official Date
For Automated Inspections, Call (772) 462-1261
For Questions, Call (772) 462-2172
St. Lucie County Land Development Code Section 11.05.01 (A) (2) states; Building Permits shall expire and
become null and void if work authorized by such Building Permit is not commenced, having called for and
received a satisfactory inspection, within six (6) months from the date of issuance of the permit, or if the
work is not completed within 18 months (permit by contractor) or 24 months (permit by owner) from the date
of issuance of the Building Permit.
FILE COPY
GENERAL NOTES
1. THE REQUIREMENTS OF APPROVAL DRAWING 05-364 ASSA/BERTHA HV ACCORDION SHUTTER BLADE HV #2 SHALL APPLY UNLESS
SPECIFIED OTHERWISE ON THIS DRAWING.
2. DESIGN LOADS FOR ROLL —UP SHUTTERS ARE: LOBBY ENTRY WEST (+56.2, —57.6 psf.) AND OPENINGS #2 (126" HIGH) +56.2, —57.6
psf. & (102" HIGH) +58.8, —59.2 psf. INTERIOR ZONE 4. LOBBY ENTRY EAST (+55.5, —97.4) AND OPENINGS #1 (126" HIGH) +56.2,
—99.4 psf. & (102" HIGH) +58.8, —106.5 psf. END ZONE 5. BASED ON 140 m.p.h. WIND SPEED, EXPOSURE C, GCpi=O. 18, .Kd=0.85,
AND IMPORTANCE FACTOR 1=1.00 IN ACCORDANCE WITH SECTION 1609 OF THE 2004 'FLORIDA BUILDING CODE WITH 2O05, 2006 AND
2007 SUPPLEMENTS.
DESIGN LOAD INDICATED ABOVE SHALL ONLY BE USED FOR OPENINGS THAT BELONG TO THE CONDOMINIUM INDICATED BELOW.
4. ALL STRUCTURAL ALUMINUM EXTRUSION COMPONENTS ARE AS SPECIFIED ON THE APPLICABLE APPROVAL DRAWING (SEE NOTE 1) OR AS
INDICATED OTHERWISE ON THIS DRAWING.
5. CONTRACTOR TO VERIFY ALL DIMENSIONS AND WALL CONDITIONS AT SITE BEFORE PROCEEDING WITH THE WORK -AND SHALL NOTIFY THIS
ENGINEER SHOULD ANY DISCREPANCIES BE FOUND THAT MIGHT ALTER THE STRUCTURAL DESIGN OF THESE SHUTTERS.
6. CONTRACTOR TO VERIFY THE EXISTENCE OF ANY UTILITIES WHICH MAY INTERFERE WITH THIS CONSTRUCTION AND SHALL- NOTIFY THIS
ENGINEER SHOULD ANY ALTERATION BE NECESSARY.
7. THE INSTALLATION CONTRACTOR IS --TO SEAL/CAULK ALL SHUTTER COMPONENT EDGES WHICH REMAIN IN CONTINUOUS CONTACT WITH THE
BUILDING TO PREVENT WIND/RAIN INTRUSION.
8. THIS ENGINEER IS NOT RESPONSIBLE FOR CONSTRUCTION SAFETY AT SITE WHICH IS THE CONTRACTOR'S RESPONSIBILITY.
!� �J SEE SCHEDULE ON SHEET 2 FOR OPENING INFORMATION.
ST LUCIECOUNTY�T�
BUILDING DIVISION
REV]
REVIEWED 6Y
DATE
PLAN AND P F1MIT . G
MUST BE KEPT ON JOB OR
NO INSPECTION WILL BE MADE
Z /b
'
FLORIDA BUILDING CODE (Nan High Velocity Hurricane
Zone)
TILLIT TESTING & ENGINEERING COMPANY
6M NW. Jeth. SC St.. M% WHPPIN dF0EN5 FS JJI40
vmne : (jo 8?f-lwo . f' : (amNr71-ISJI
EB-06067I9oneamm�
WALTER A. 7xur Jr A E
MnRmA Ife. 6 4AIR7
PdSlA(L4110N a BER➢l4 H.V. ACCORWONiSNUIiR
SNU U (ME W) .
AG
ORAwN BY.
T A
HIBISCUS I CONDOMINIUM
3880 NORTH AIA
FORT FIERC& aORDA J4949
09121107
DATE
07-241
ORAWINO No
u:e rx
nrsmmx
ma
-
SHEET 7 OF 2
THESE PLANS AND ALL'PROPOSEOWORK_.__
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIEF INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
COMM WITH I6 M- PwwkE CODES,
CONCEALED FASTENERS OR ATTACHMENTS
ARE THE RESPONSIBILITY OF THE
CONNOT08080
/NTE/L02. Fuo'
N
,F,r60
4
q 29
710
a
•
33'
LOBY iMRY_
6
3 7 • 29 .. 4
4
17
17
I
Q W
20
6
10
11 4 .
15
1 t
15 4
10
8 20
6
B
6 18
16 6
6
8
y
10
73
50 50
47
:
65
57 50
73
•10
�
s
.8 6n
5
5
6n$ ^
28
LOGY ENTRY
28
7.
p
425 4
a 25. a
N
6 17 8
GROUND FLOORS WINDOWS
(PIA li) 6 17 6
zw
0 .20W Fl 1A17EA2/6.e ?-af1E '�itLD / TUNg Etlp /NT�Q/d2 20 cLE fILD .20&
. a
k;T
33
83
17 a 4
� •710
7
29 44 17\20
_.
q�'17
/.20 6 10
11 q 15 .-. g
12
4 11 10 6
QZO
��
6
22
15 6
.
n
6 16
16 6.
OPENING #t.
OPENING #1 8
73
0
10 73 r50
50 47
55 57 50
10
O
n
' 01 UNITS
02 UNITS 03 UNITS
04 UNITS . 05'UNITS
6
OPENING #2
• 6
6
6• OPENING #2
�
{iv
9
a 6
6• 6
5 6
9
�U
h
11 23 3
6 5 i1 6.
y
28
iY! T fo
.1CL� 28
FLOORS 1 - 12 WINDQWS (PLAA)
DESIGN WIND LOAD (pafa AND CORRESPONDING MAXIMUM SHUTTER SPAN AND
ANCHORS SPACING (in) SCHEDULE FOR A GIVEN OPENINGLOCATION, FOR
CONCRETE INSTALLATIONS.'
'
UNITS
SIZES
WIDTH x HOT.
DESIGN PRESSURES
END ZONE 5
'OPENINGS #1 (pst.)
DESIGN PRESSURES
INTERIOR ZONE 4
OPENINGS #2 (psf.)
ANCHOR SPACING
1/4°0 TAPCON
RW/BUILDEX
W/EAIB 3/4n MIN
MOUt4TIN0
INSTALLATION
SHT. 22 OF 26
/ DWG,OS-364-
B1 2
TOP BOTIOM
LOGY WEST
270"x127"
---
+56.2 / -57.6
3°
LOGY EAST
382"x134'
+55.5 / -97.4
---
2 1/2"
® .�
#1201.--•-
j:108"x126
#1101
tOB'x126'
+58.2 -99.A�
+56.2 /=57ifi^-
2`7/z - 3•
,01001
108'x102,
+58:8 / -106.5
+58,8 / -59.2
3 1 2 4 1 2°
#901
108'x102'
+58.8 / -106.5
+58.8 / -59.2
3 1/2
4 1 2"
#801
108'002'
+58.8 / -106.5
+58.8 / -59.2
9701
108'002'
+58.8 / -106.5
+58.8 / -59.2
3 1/4' 4 1 2"
#601
108"x102'.
+58.8 / -106.5
+58.8 / -59.2
3 1/2 4 1 2"
#501
108'x102'
+58.8 / -106.5
+58.8 /'-59.2
2"
#401
108'X102"
+58.8 / -106.5
+58.8 / -59.2
2'
#301
108'x102'
+58.8 / -106.5
+5B.8 / -59.2
2"
#201
105'x102'
+58.8./ -106.5
+58.8 / -59.2
2'
11/2�
#101
108"xl26"
+56.2 / -99.4
+56.2 / -57.6
3'
#1205
108'x126'
+56.2 / -99.4
+56.2 % -57.6
3•#1105
108°x126'
+56.2 / -99.4
+56.2 / -57.6
3•#1005
108x10Y
+58.8. / -106.5
+58.8 / -59.2
4 1 2
#905
108"x102'
+58.8 / -106.5
+58.8 / -59.2
3 1/2 4 1 V
.#805
108"x102"
+58.8 / -106.5
+58A / -59.2
3 1/2 4 1 2"
#705
1081x102'
+58.8 / -106.5
+58.8 / -59.2
3 1/2 4 1 2"
0605
1081xIO2'
+58.8 / -106.5
+58.8 / -59.2
3 1/2' o
4t2
#505
108'x102'
+58.8 / -106.5
+58.8 / -59.2
3 1/2 4 1 2"
#405
108'x102'
+56.8 / -106.5
+58.8 / -59.2
3 1/2 4 1 2"
#305
708°x102'
+58.8 / -106.5
+58.8 / -59.2
3 1/2 4 1 2"
#205
108N126"
+56.2 / -99.4
+56.2 / -57.6
2 1/2 3"
1
FLORIDA BUILDING CODE (Non High Velocity .HuTFicone Zone)
L E C O 'IN C.
mTuU� a(ej Amay
92.
fig EfffRT SMlllEk s el�
°R1
H.B/SCUSJB80 I NORTHlA CONDA1A""UM
FORT PIERC& FLORIDA 34949 <
• 09127/07
GATE
07-241
p/LIWING •Na
STING 0: ENGINEERING COMPANY
to S/,07a7, xRaIa J�. 91=7s1-11wa
WALM? A TILIIi In A E
FLORIDA LI 44767
� �
cacv��
-
rsx x.
1 �-
as
r
-
-
SHEET 2 OF 2
a
-
THESE PLANS AND ALL PROPOSED -WORK---------•-----------____ __.___-_.. -
CONCEW FASTENERS OR ATTACHMEM ARE SUBJECT TO ANY CORRECTIONS
ARE THE RESPONSIBIWTYOFTHE REQUIRED BY FIELD NSPECTOT9THAT FILE
` MAY BE NECESSARY
WHIRACTOR OF RECORD OOMPR WITH, AAP49M. 4 99P1,9g
r�l