Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSI "alc: V I I /rVV LUC: / a u.o.= 1 neceipm J 5 1 rermit # V i115. - S �. ',-,,,Lucie County Building SC 2300 Virginia Avenue.. Ft. Pierce, FL 34982-5652 �NNFo ' lir Tel:772-462-1553 �t �Y off° 90 �oR,oP APPLICATION FOR ROOF PERMIT 4c�e c°u17ty SEER RSE FOR INSTRUCTIONS 1. Location/Site Address: .r_ )V ) 2. 'Parcel ID -Number: ��a 0� -..:.. . 0 4. 6. Off ce Use Only .. Section Township' Range -.Ma Page, -Zoning Land Use I Initials ;. �� Description of Project or Work Activity Q Total Roof Area (square feet • 5. Roof Pitch: Type of Roof: Fiberglass Shingle ❑Barrel/Tile Ceramic El Wood Shake14 Shingle.. Tar & Gravel ❑Modified Bitumen ❑ Metal I ❑ Other (specify) N.O.A. — Product Approval required for All Types of Roofing Material All Commercial Roofing Requires Design by an Engineer or Architect (two Sets) 7. Owner Information Name: Address: City: L State: '(, Zip.:' Phone: D�� 9. Value of Construction: $J�y Note: Dry -in and. Final Inspection Required. S. Contractor Information FL Reg/Cert County Cert#: Business Name: `tea ar ZQ Phone�Z g7 ZCIax 2Ca� 2 O. Additional. inspection may- be.required per'Pi•oduct Approval OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in compliance with all applicable laws regulating construction and zoning. c oxq A&� -z o PRINT QU LIFIERS/OWNERS NAME pp SIGNATU`J OF QUALIF R/OWNER STATE OF FLORIDA, COUNTY OF �W�/w ACKNOWLEDGED BEFORE ME THIS DAY OF . 2 BY WY �- V` WHO 1STERSONALLY KNOWN TO ME OR WHO HAS PRODUCED..,., . As IDENTIFICATION. l �\ �� l (seal) SIGNATURE OF NOTARY TYPE OR PRINT NAME OF NOTARY - ,�PRv Pue C. J. HARRELL TITL : N TARY PUBLIC COMMISSION NUMBER 1; J�t-2 V * * MY COMMISSION i# DD 420650 St. Lucie County Roof Permit Application rev. 7/18/05' dmg �'q°` Bonded Thru Budget Notary SeryEXPIRES: April 19, 200i9 ces �oFc�o 9 ry NOTICE TO OWNER: - FAILURE TO RECG.Z A NOTICE OF COMMENCEMENT MAY RES'L,L,' IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING; CONSULT YOUR LENDER OR ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. EXEMPT: A/C - 'HEAT REPLACEMENT WITH CONTRACT UNDER $5,000. INSTRUCTIONS Please complete all information in the space provided. All information must be printed (use black or blue ink only) or. typed. This roof permit application is to be used only for those activities that are not otherwise included under a primary building. permit. This application may not be used for any activity that includes structural alteration. Building activities involving structural: alteration; in addition to the roof -work, must. be permitted through the regular building permit review process. The information to be provided with this application includes: 1. Location/Site Address Indicate the street address or general location of the property where the building activity is takirig"place 2. Parcel ID Numlier- Indicate the tax identification number of the property where the building activity. is taking place. 3. Description of Projector Work Activity Briefly describe the building activity to take place. 4. Total Roof Area 5. Type of Roof 6: Owner Information 7. Contractor Information.. 8.. Value of Construction Indicate total roof area to be affected by this permit. Also indicate the pitch of the roof,expressed as a standard ratio of run rise. Indicate the type of roof being repaired of resurfaced.. Indicate the name and address of the owner of the property. on which building activity is taking place. Indicate the State of Florida registration number (if applicable), St. Lucie County contractor license number and the name of the business doing the work. Indicate the total value of the work to take place. Total cost of construction includes all material and labor costs associated with the building/construetion activity: Construction value -is used to determine the permit fee. St. Lucie County reserves the right to question and/or modify the indicated value of construction- if it is demonstrated that the submitted figures are not consistent with similar types of construction. This application can be submitted to St. Lucie :County Building and Zoning, 2300 Virginia Avenue, Fort Pierce, FL 34982. All permit applications must be filled out completely before submission. No applications will be accepted for processing after 4:30 P.M. For assistance in completing this application, please call (772) 462-1553, during regular office hours (8:00 AM - 5:00 PM), Monday through Friday. Upon issuance of this permit, required inspections can be scheduled by calling (772) 462-1261. St. Lucie County Roof Permit Application rev. 7118/05 dmg EDWIN M. FRY, Jr., CLERK OF THE CIRCUIT FILE # 3113816 AFfEltRFCp OR IN[•.RF'rtra��� BOOK 2�'— —', PAGE 2880 Gary 11=0 Roofioq 881•,A 8W Ltlkehurat Or. mmmaMMUL Port at Lucia FL 34883 C SAINT LUCIE COUNTY �7 at 01 E Ci NTi''�_.) THIS 70 CF-R T IFY THAT THIS IS A 'TRUE AN1)] 6€mEcTt0Py 0FTFI DRIGINAL. EuW iN 7 .. FfiY, By, :07 PM `.i ar . resrnW nor rranrrfiog j,,p NOTICE OF CO)VIl�NCEMEIy'I' The undersigned hereby given notice that imptnvement will be made to certain teal Florida statutes the following information is provided in the Notice of coumnain red PmP�Y. and m accordance with Chapter 7I3, PROPERTY (Legal ) L-hh a, - - DESCRIPTION OF 3. OWNER d. Name and address of fee simple titleholder 5. 6. LENDER'S NAME, ADDRESS AND PHONE NU11t03$R; 7. Persons within the State of Florida designated by Section 713.13 (1)(a) 7., Florida Statutes: Owner upon whom notices or other documents may be served as provided by NAME, ADDRESS AND PHONE NUMBER: 8. In addition to himself or herself, Owner designates the following to receive a 713.13 (1)(h), Florida Statutes: copy of the Lienor's Notice as provided in Section NAME, ADDRESS AND PHONE NUMBER: 9. Expiration date of notice specified) of commencement (the expiration date is I year from the date of recording unless a different date is _ . and street addwss) TAX FOLIO NUMBER: �� �S ! fAAV-T r� 2 `1 ---- c. interest in property. Signature of OvAer or Print Name and Provide Signatory's Ti�pi@i>�e Owner's Authorized O icer/Director/Psrtner/Manager . •••• LYNN MARZO * * MY COMMISSION i DD 306715 State of Florida EXPIRES: Aprf7 5, 2MB _ 1 1 � � �44a F�oa��' Bonded ThN Budgx4 pola�p Se�Yites County of may=--` '_"` The foregoing instrument w owledged before me this d of�� By q �' 20_, as _ane of peiso �^ (Type ofaumorlty.. e.g. er. Owner, offictrustee, attomey in fact) ame of party on Wholf of whom instrument was ex etatbed) Personally Known or produced the following type of ID: rn�c LYNN *ipt� �� * MYr..n .. :: t a141i6715 (Prince ame of Not ?unl 4 t 6 ary Public) (Sign of Notary Pabli) (Seal) ''Fa F. ?` A,u: Under penalties of perjury. I declare that I have read the foregoing and that the belief (section 92.525, Florida Smutes). facts in it are true to the hest of my knowledge and Signature(s) of Owner() or Owner(s)' Authorized Offlcer/Dlreetor/PartoedMansger who signed above. By:''/�, �4fji•x Rev. MnonwTpr Sigaatttne). (Printed Name) ILE M I A M I•DA COPY BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION MIAMI-DADE COUNTY, FLORIDA METRO-DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130-1563 (305) 375-2901 FAX (305) 375-2908 Owens Corning '1105 PWS Aflo ALL pRopOSED9YOI�!( One Owens Corning Parkway ARE SUMCT TO ANY CORRECTION$ =` Toledo, OH 43659 REQUIRED BY FIELD INSPECTORS THAT A SCOPE: MAY RE NECESSARY IN ORDER TO -: This NOA is being issued under the applicable rules and regulations governing the use of constructitpkg on inatenaT. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The BCCO (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BCCO reserves the right to revoke this acceptance, if it is determined by BCCO that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. fi ridg RPe O DESCRIPTION-. OKA_ LABELING: Each unit shall bear a permanent label with the manufacturers name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA #02-1104.04 and consists of pages 1 through 3. The submitted documentation was reviewed by Frank Zuloaga; RRC. ST. LUCIE COU BUILDING D N REVI FOR P CE REVIEWED BY DATE - .2 9, O PLAN AND'PERMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE . 1`TOA No 04=65T06 Ex atiom Date:_ I2J12J07 Approval Date:07122%04 Page 1 of 3 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub-Cateeorv: 07310 Asphalt Shingles Materials Laminate Deck Type. Wood L SCOPE This revises a roofing system using Owens Corning Oakridge PRO 30 AR. Asphalt shingles manufactured by Owens Coning as described in Section 2 of his Notice of Acceptance. 2. PRODUCT DESCRIPTION Product Dimensions Test Product Description Specifications Oakridge PRO 30 AR 13 114 " x 38 3/a" TAS 110 A heavy weight, fiberglass reinforced Accessory Shingles various proprietary asphalt shingle. Accessory shingles for hip, ridge and starter strip applications. 3. EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Celotex Corp. Testing Services 258495A TAS 100 06/01/98 Underwriters Laboratories, Inc. 94NK9632 TAS 107 06/30/98 96NK30503 ASTM E 108 10/11/96 98NK16342 ASTM D 3462 05/14/98 OINK44201 UL 997 09/09/02 02NK02878 ASTM D 3462 09/26/02 PRI Asphalt Technologies, Inc. OCF-064-02-01 TAS 100 08/23/02 4. LIMITATIONS 4.1 Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 4.2 Shall not be installed on roof mean heights in excess of 33 ft. 4.3 All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B-72 of the Florida Administrative Code. 5. INSTALLATION 5.1 Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 5.2 Flashing shall be in accordance with Roofing Application Standard RAS 115 5.3 The manufacturer shall provide clearly written application instructions. 5.4 Exposure and course layout shall be in compliance with Detail W, attached. 5.5 Nailing shall be in compliance with Detail W, attached. 6. LABELING 6.1 Shingles shall be labeled with the Miami -Dade Logo or the wording "Miami -Dade County Product Control Approved". 7. BUILDING PERMIT REQUIREMENTS NOA No.: 04-0510.04 Expiration Date: 12/12/07 Approval Date:07/22/04 Page 2 of 3 J 7.1 Application for building permit shall be accompanied by copies of the following: 7.1.1 This Notice of Acceptance. 7.1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. 8. MANUFACTURING PLANTS 8.1 Jacksonville, FL 8.2 Savannah, GA I DETAIL A DETAIL B END OF THIS ACCEPTANCE EXPOSURE NOA No.: 04-0510.04 nAL Expiration Date: 12/12/07 Approval Date:07/22/04 Page 3 of 3 ROOFING APPLICATION STANDARD (RAS) No.115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION 1. Scope 4. Underlayment 1.1 This roofing application standard has 4.1 Minimum prescriptive underlayments been developed to provide a responsive shall be one of the following, unless oth- method of complying with the require- erwise specifically noted in roofing as- ments of Chapters 15 and 16 (High-Ve- sembly Product Approval: locity Hurricane Zones) of the Florida Building Code, Building while providing • A double layer of an ASTM D 226, a prescriptive method of installing asphal- Type I,with a 19-inch headlap; or tic shingles. • A single layer of an ASTM D 226, type II with a 4-inch headlap; or A single layer of an ASTM D 2626 2. Definitions coated base sheet with a 4-inch headlap. • All endlaps shall be a minimum of 6 2.1 For definitions of terms used in this appli- inches. cation standard, refer to ASTM D 1079 • All valleys shall be woven. and the Florida Building Code, Building. 4.2 All underlayments shall be fastened with 3. General minimum 12 gage by 1 `/4 in. corrosion -re- sistant annular ring shank roofing nails fas- tened trough minimum 32 gage by 15/8 in. 3.1 Asphaltic shingles shall not be installed diameter tin caps. Maximum fastener spac- on roof mean heights .greater than 33 feet, ing shall be 6 in. o.c. at the laps with two ad - unless specifically specified in the roof ditional rows in the field at a maximum I I assemblies Product Approval. Roof slope spacing of 12 in. o.c. Nails shall be of suffi- criteria shall be in accordance with Table cient length to penetrate through the 9heath- 1515.2. ing or wood plank a minimum of/,e,in. or penetrate 1 inch (25 min) or greater thick-. ness of lumber a minimum of 1 in., except 3.2 Where asphaltic shingles are to be in- where architectural appearance is to be pre- . stalled.over insulated roof deck, a suitable served, in which case a minimum of in. nailable substrate, in accordance with nail may be used. Section 1520.5.7 must be installed over . the insulation prior to the installation of approved underlayment and shingles. 4.3 If the underlayment is a self -adhering membrane; the membrane shall be ap- plied over a mechanically attached an- 3.3 Asphaltic shingles shall be installed in com- chor/base sheet attached in compliance I I pliance with the Product Approval installa- with this section above. . tion drawings, but in no case with less than six approved roofing nails (12 ga. by V/4 in. corrosion -resistant annular ring shank roof- 5. Metal Accessories ing nails) or approved fastening devices which penetrate through the sheathing or /16 in. 5.1 All metal accessories shall be in compli- wood plank a minimum of or pene- trate a 1 in. or greater thickness of lumber a ance with Section 1517.E of the Florida I I minimum of 1 in. except where architec- Building Code, Building and RAS 111. tural appearance is to be preserved, in which case a minimum of 3/4 in. nail may be used. 5.2 Eave and gable drip metal vertical face shall be a minimum of 11/2 inches and shall ex- tend down not -less than'/z inch below the sheathing or other member immediately FLORIDA BUILDING CODE -TEST PROTOCOLS HVHZ (RAS)115.1 ,ar (RAS) No. 115 t. 6. contiguous thereto. In all cases, the deck flange shall be not less than 2 inches in width. Where required, a continuous clip (hook strip) shall be installed in compliance with RAS 111. 5.3 Eave and gable drip metal shall be joined by a lapped of a minimum of 4 in. and the entire interior of the joints shall be coated with approved flashing cement. Eave and gable drip metal shall be fastened with minimum 12 gauge annular ring shank nails at a maximum spacing of 4 in. o.c. The nails shall be manufactured from similar and compatible material to the ter- mination profile. All composite materials shall be fastened with nonferrous nails. All metal profiles shall be installed in compliance with RAS 111. 5.4 Valley metal shall be a minimum 16 in. wide rolled or preformed material of thick- ness' in compliance with Section 1517.6 of the Florida Building Code, Building. Valley metal shall be set over the underlayment, or over an optional 18 in. sweat sheet. Fasten valley metal with minimum 12 gage by 11/4 in. annular ring shank roofing nails of simi- lar materials 12 in. o.c.1 in. in from each ex- terior edge. The entire edge of the flange shall be sealed, covering all nail penetra- [ions with flashing cement and membrane. All horizontal laps shall be a minimum of 6 in. and shall be fully embedded with ap- proved flashing cement. No nails shall be permitted in the center of the valley. Shingle Installation 6.1 At all intersections, eaves, rakes, valleys, and gable ends the shingles and starter strips shall be set in a minimum 8-in. wide strip of approved flashing cement. Maximum thickness of flashing cement shall be 1/8 in. as excessive use of the cement may cause blistering, or bleed through. Shingles shall not extend more than '/4 in. beyond the cave drip. 6.2 The starter strip may be either a row of nonlaminated shingles trimmed to the shingle manufacturer's recommendations or a strip of mineral -surfaced roll roofing not less than 7 in.wide. 6.3 If self-sealing shingles are used for the starter strip, remove the tab portion of each shingle and position the remaining strip with the factory -applied adhesive face up along the eaves. Trim material from the end of the first shingle in the starter strip according to manufacturer's specifications to ensure that the cutouts of the first course of shingles are not placed over the starter strip joints. Fasten starter strips parallel to the eaves along a line above the.eave line according to manufac- turer's specifications. Position fasteners to insure they will not be exposed under the cutouts in the first course. 6.4 For shingles without a self-sealing strip the tabs shall be removed and approved flashing cement shall be applied in spots, approximately the size of a quarter at the corner of each tab of the first course. Starter shingles shall be nailed along a line not greater than 4 in. above the cave line nailing not greater than 6 in. o.c. En- sure that the cutouts of the first course are not placed over the starter strip joints. 6.5 If roll roofing is used for the starter strip, nail along a line not greater than 4 inches above the cave line nailing not greater than 12 inches o.c. Approved flashing ce- ment shall be applied as noted above for nonsealing shingle starter. If more than one piece of roll roofing must be used, the end joint shall be butted. Joints shall be staggered with succeeding shingle joints, and the number of starter joints shall be kept to a minimum. 6.6 First course shall be laid straight, check- ing it regularly during application against a horizontal chalk line. A few vertical chalk lines aligned with the ends of shin- gl,es in the first course will ensure proper alignment of cutouts. A shingle hatchet is an acceptable alternative to the use of suc- ceeding chalk lines. The first course starts with a full shingle, while succeeding courses shall be installed in strict compli- ance with the shingle manufacturers' Product Approval course layout detail. 6.7 Rake and valley courses shall be termi- nated with shingles not less than 12 in. in length. To obtain the correct exposure for square -tab strip shingles, align the butts (RAS) 115.2 FLORIDA BUILDING CODE — TEST PROTOCOLS HVHZ r � � (RAS) No. 115 with the top of the cutouts in the course below. Install no -cutout shingles and those with variable butt lines according to the manufacturer's directions to obtain PROPERLY DRIVEN correct exposure. NOTE: Follow manufacturer's .instruc- tions concerning shingle align- ment. See "Exposure, Course Layout, and Fastening Detail" in shingle manufacturer's Product Approval. 7. Fastening IMPROPERLY DRIVEN UNDERORNEN OVERORM CROONED ASPHALT SHINGLES UNDERLAYMENT DETAIL A 7.1 Use six approved nails per shingle. Place 8 .2 Open valley: Snap two chalk lines, one on each side of the valley centerline over the the fasteners in strict compliance with full length of the valley flashing. Locate the shingle manufacturers Product Approval I upper ends of the chalk lines 6 in. apart in course layout, fastening details. the center of valley at the ridge (i.e., three inches to either.side of the valley center- 7.2 Align the shingles properly to avoid ex- line). The lower ends should diverge from each other a minimum of /8 in. per linear posing fasteners in the course below. foot of valley length, (i. e., for an eight foot Drive the fasteners straight and do not long valley the chalk lines shall be 7 inches break the shingle surface with the fastener apart at the eaves). head. Do not drive fasteners into knot holes or cracks in the roof deck. Repair faulty fastening immediately. If fastener As shingles are applied toward the valley, I I is improperly driven or exposed, remove trim the last shingle in each course to fit the fastener and repair the hole in the shin- on the chalk line. Never use a shingle gle with approved flashing cement or re- trimmed to less than 12 inches in length to place the entire shingle. finish a course running into a valley. If necessary, trim a tab off the adjacent shin- gle in the same course to allow a longer 7.3 Do not nail into or above factory -applied portion to be used, trim 1 inch on a 45-de- adhesives. Ensure no cutout or end joint is gree angle from the upper corner to direct less than 2 inches from a nail in an under- water into the valley and prevent it from. lying course. Start nailing from the end penetrating between the courses. Finally, nearest the shingle just laid and proceed to form a tight seal, cement the shingle to across. Do not attempt to realign a shingle the valley, lining with a minimum by shifting the free end after two nails are eight -inch width of asphalt flashing ce- in place. Drive nails straight so, that the ment. There should be no exposed nails edge of the nail head does not cut into the along the valley flashing. shingle. Nail heads should be driven flush with the shingle surface. Fasteners shall not be improperly driven (see Detail A). 8.3 Closed cut valley: With valley flashings already in place, apply the first course of shingles along the eaves of one of the in- tersecting roof planes and across the val- 8. Valleys ley. For proper flow of water over the trimmed shingle, always start applying the shingles on the roof plane that has the 8.1 Valleys may be applied in open, closed or lower slope or lesser height. Extend the end shingle at least twelve inches onto the woven fashion. Valley metal shall be in adjoining roof. Do not make a joint in the compliance with Section 5.4. valley. If a shingle falls short, add in one or two tab sections so that joint occurs FLORIDA BUILDING CODE — TEST PROTOCOLS HVHZ (RAS) 115.3 (RAS) No. 115 outside the line of the valley. Apply suc- ceeding courses in the same manner, ex- tending them across the valley and onto the adjoining roof. Press shingle tightly into the valley. Use normal shingle fasten- ing methods except that no nails should be within six inches of the valley centerline and two nails shall be placed at the end of each shingle crossing the valley. Snap a chalk line two inches from the centerline of the valley on the under -shingled side. Then apply shingles on the under shingled side. Trim the shingles as they are being installed to the chalk lines to ensure a neat installation. Trim one inch on a 45-degree angle from the upper corner of each shin- gle upon installation. This will direct wa- ter into the valley. Finally embed each end shingle in a 3-inch (76 mm) wide strip of flashing cement. 8.4 Woven valley: The valley flashing should already be in place as described earlier. Shingles on the intersecting roof surfaces may be applied toward the valley from both roof areas simultaneously or each roof area may be worked separately up to a point about three feet from the center of the valley and the gap closed later. Re- gardless of which procedure is followed; apply the first course, along the eaves of one roof area up to and over the valley with the last shingle extending at least 12 inches onto the intersecting roof. Then apply the first course of the intersecting roof along the eaves and extend it across the valley over the top of the shingle al- ready crossing the valley and at least 12 inches onto the other surface. Apply suc- cessive courses alternately from the ad- joining areas, weaving the valley shingle over the other. Press each shingle tightly into the valley. Use normal shingle fasten- ing methods except that no nails should be within six inches of the valley centerline and two nails shall be placed at the end of each shingle crossing the valley. 9. Flashing 9.2 Option A: All wall abutments shall be flashed with a minimum of 4 in. by 5 in. "L" metal flashings of materials and thickness in accordance with Section 1517.6 of the Florida Building Code, Building. The metal "L" flashing shall be set in approved flashing cement and set flush to base of wall and over underlayment (see Detail B). Both hori- zontal and vertical metal flanges shall be fastened 6 inches o.c. with approved fas- teners. Fastening shall be in accordance with RAS 111. All laps shall be a mini- mum of 4 inches fully sealed in approved flashing cement. Flashing shall start at the lower portion of the roof to ensure wa- ter -shedding capabilities of all metal laps. The entire edge of the metal flashing shall be sealed covering all nail penetrations with approved flashing cement and mem- brane. The metal "L" flashing shall be counter flashed. All metal counter flash- ing shall be installed in accordance with RAS 111. 9.3 Option B: Roof planes that butt against Vertical walls shall be step flashed with 10 in. long metal shingles which are 2 in. wider than the exposed face of the roofing shingles (see Detail Q. Place the first flashing unit over the end of the starter strip and position it so that the tab of the end shingle in the first course covers it completely. Secure the horizontal arm to the roof with two approved roofing nails. Do not nail flashing to the wall; settling of the roof could damage the seal. Apply the 9.1 All shingles that butt against wall flash- ings shall be step bulled with approved flashing cement a minimum of eight DETAIL B inches, and all roof planes that butt against vertical walls shall be flashed in one of the following manners: (RAS) 115.4 FLORIDA BUILDING CODE — TEST PROTOCOLS HVHZ (RAS) No. 115 FLASHING PLACED UPSLOPE FROM EXPOSED EDGE OF SHINGLE EXTENDING 4 INCHES OVER UNDERLYING SHINGLE AND 4 INCHES UP VERTICAL WALL MINIMUM 2-INCH HEADLAP UNDERLAYMENT TURNED UP VERTICAL WALLS MINIMUM 4 INCHES DETAIL C first course of shingles up to the wall. Po- sition the second step flashing strip over the end shingle in the first course 5 inches up from the butt.so that the tab of the end shingle in the second course covers it completely. Fasten the horizontal arm to the roof. The second course of shingles follows, the end is flashed as in the pre- ceding courses and so on to the top of the intersection. Bring siding or other wall treatment down over the vertical sections of the step flashing to serve as cap flash= ing. Wall treatment or cap flashing shall terminate a minimum of 1 in. above the roofline. All metal counter flashing shall be installed in accordance with RAS 111. 9.4 Head/apron flashing at all vertical end walls: Apply shingles up the roof until a course must be trimmed to fit at the base of the vertical wall. Adjust the exposure slightly in the previous two courses so that the last course is at least 8 inches wide. Apply a continuous piece of metal flash- ing over the last course of shingles by em- bedding it in approved flashing cement and nailing it to the roof. The metal flash- ing strip shall be bent to extend at least 5 inches up the vertical wall and at least 4 inches onto the last shingle course. Do not ...................... nail the strip to the wall. Apply an addi- tional row of shingles over the metal flashing strip, trimmed to the width of the strip. Bring siding down over the vertical flashing to serve as cap flashing. Wall treatment or cap flashing shall terminate a minimum of 1 in. above the roofline. Do not nail siding into the vertical flashing. If the vertical front wall meets a side wall, as in dormer construction cut flashing so that it extends at least 7 inches around the cor- ner. Continue up the side wall with step flashing as detailed above. 10. Soil Stacks and Vent Pipes 10.1 Apply shingles up to the vent pipe. Cut a hole in a shingle to go over the pipe and set the shingle in ASTM D 4586 flashing ce- ment. A preformed flashing flange that fits snugly over the pipe is then placed over the shingle and vent pipe and set in approved flashing cement. Place the flange over the pipe to lay flat on the shin- gle below. After the flashing is in place, resume shingle application. Cut shingles in successive courses to fit around the FLORIDA BUILDING CODE — TEST PROTOCOLS HVHZ (RAS) 115.5 (RAS) No. 115� 11. pipe and embed them in approved flash- overlap the flashing in an 8" bed of ap- ing cement where they overlap the flange. proved flashing cement. Place the rear Avoid excessive use of cement as it may base flashing over the cricket and the, high cause blistering. Do not drive fasteners side of the chimney. Chimney crickets close to the pipe. The lower part of the shall be waterproofed in compliance with flange shall overlap the lower shingles the shingle manufacturers published liter - and the side and upper shingles shall over- ature. All chimney flashings shall be lap the flange. countered flashed. Metal counter flashing shall be in accordance with RAS 111. 10.2 For ventilator and exhaust stacks, follow the same procedure, but bring the shingles 12• up to the pipe from both sides and bend the flange over the ridge to lie in both roof planes, overlapping the roof shingles at all points. Ridge shingles are then positioned to cover the flange. Embed the ridge shin- gles in approved flashing cement where they overlap the flange. Roof ventilators shall be flashed in accordance with'venti- lators Product Approval. d Chimneys 11.1 Chimneys shall be flashed with a two-piece base and cap flashing to allow for differential movement. Apply shin- gles up to the front edge of the chimney before any flashings are installed. Apply a coat of ASTM D 41 asphalt primer if the chimney is constructed of masonry or metal to seal the surface and to provide good adhesion to all points where flashing cement will later be applied. 11.2 Install flashing in accordance with Sec- tion 9 above. Apply the base flashing to the low side of the chimney first. Bend the base flashing so that the lower section ex- tends at a minimum of 4 inches over the shingles and the upper section extends a minimum of 12 inches up the vertical face of the chimney. Work the flashing firmly and smoothly into the joint between the shingles and chimney. Set both the roof and chimney overlaps in approved flash- ing cement placed over the shingles and on the chimney face. The flashing shall be secured in accordance with RAS 111. Use metal step flashing for the sides of the chimney, positioning the units in the same manner as flashing on a vertical side wall, in accordance with Details A and B herein. Secure each flashing unit to the masonry with approved flashing cement and to the deck with approved nails. Em- bed the end shingles in each course that Hips and Ridges 12.1 Apply premanufactured hip and ridge shingle components or cut hip and ridge shingles from manufacturer's strip shin- gles. Lay hip and ridge away from prevail- ing wind. Insure all fasteners are covered. Exposure shall not exceed 5 inches. Taper the lap portion of each cap shingle slightly so that it is narrower than the exposed por- tion. (RAS) 115.6 FLORIDA BUILDING CODE — TEST PROTOCOLS HVHZ Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1148 http://stl u cieco. g ov/ce BUILDING PERMIT Issued: 09/27/2007 Conf #; 700 Permit #: SLC- 0709-0360 Job Location: 3712 DORAL CT City: PORT ST LUCIE Permit Type: Roof Job Description: TEAR OFF AND REROOF FIBERGLASS SHINGLES 1800 SQ FT 2/12P Subdiv: Savanna Club Plat Phase Three Lot: 32 Block: 43* Parcel: 3425-705-0168-00013 Setbacks Left: Right: Front: Rear: Zoning: PUD Number of Units: 1.00 Floors: 1 Buildings: 1 Square Footage: 0.00 Minimum Floor Elevation: Flood Map: Flood Zone: Elev: Job Value: $ 4,300.00 Page 1 Permit holder acknowledges through acceptance of this permit that separate permits must be obtained as required by the Florida Building Code including those for all electric, plumbing, mechanical, roofing, and structural work. Further, he/she acknowledges responsibility to comply with all requirements of the 2004 Florida Building Code. NOTICE: In addition to the requirements in this permit, there may be additional restrictions applicable to this property that may be found in the records of this County, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. s:553.79(10), F.S. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR BUILDING IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. s.713.135, F.S. Christopher Lestrange �'• a7 0 7 Building Official Date For Automated Inspections, Call (772) 462-1261 For Questions, Call (772) 462-2172 St. Lucie County Land Development Code Section 11.05.01 (A) (2) states; Building Permits shall expire and become null and void if work authorized by such Building Permit is not commenced, having called for and received a satisfactory inspection, within six (6) months from the date of issuance of the permit, or if the work is not completed within 18 months (permit by contractor) or 24 months (permit by owner) from the date of issuance of the Building Permit. Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 http://stiucieco.gov/ce Date: 27 September 2007 Job Address: 3712 DORAL CT Received By: humphreya Paid With: CK Paid By: GARY MARZO INC Buildmg' Receipt', Sign: Receipt M 0000057730 - 'ermit Number: SLC- 0709-0360 Amount: $180.00 �redit Card Number: Check Number: 2629