HomeMy WebLinkAboutSUBMITTED PAPERSI "alc: V I I /rVV LUC: / a u.o.= 1 neceipm J 5 1 rermit # V
i115. - S �. ',-,,,Lucie County Building SC
2300 Virginia Avenue.. Ft. Pierce, FL 34982-5652 �NNFo
' lir Tel:772-462-1553 �t �Y
off° 90 �oR,oP APPLICATION FOR ROOF PERMIT 4c�e c°u17ty
SEER RSE FOR INSTRUCTIONS
1. Location/Site Address: .r_ )V )
2. 'Parcel ID -Number: ��a 0� -..:.. .
0
4.
6.
Off ce Use
Only ..
Section
Township'
Range
-.Ma Page,
-Zoning
Land Use
I Initials
;.
��
Description of Project or Work Activity Q
Total Roof Area (square feet • 5. Roof Pitch:
Type of Roof: Fiberglass Shingle ❑Barrel/Tile Ceramic El Wood Shake14
Shingle..
Tar & Gravel ❑Modified Bitumen ❑ Metal
I
❑ Other (specify)
N.O.A. — Product Approval required for All Types of Roofing Material
All Commercial Roofing Requires Design by an Engineer or Architect (two Sets)
7. Owner Information
Name:
Address:
City: L State: '(,
Zip.:' Phone: D��
9. Value of Construction: $J�y
Note: Dry -in and. Final Inspection Required.
S. Contractor Information
FL Reg/Cert
County Cert#:
Business Name: `tea ar ZQ
Phone�Z g7 ZCIax 2Ca� 2 O.
Additional. inspection may- be.required per'Pi•oduct Approval
OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done
in compliance with all applicable laws regulating construction and zoning.
c oxq A&� -z o
PRINT QU LIFIERS/OWNERS NAME pp SIGNATU`J OF QUALIF R/OWNER
STATE OF FLORIDA, COUNTY OF �W�/w ACKNOWLEDGED BEFORE ME THIS DAY OF
. 2 BY WY �- V` WHO 1STERSONALLY KNOWN TO ME OR WHO HAS PRODUCED..,., .
As IDENTIFICATION.
l �\ �� l (seal)
SIGNATURE OF NOTARY TYPE OR PRINT NAME OF NOTARY - ,�PRv Pue C. J. HARRELL
TITL : N TARY PUBLIC COMMISSION NUMBER 1; J�t-2 V * * MY COMMISSION i# DD 420650
St. Lucie County Roof Permit Application rev. 7/18/05' dmg �'q°` Bonded Thru Budget Notary SeryEXPIRES: April 19, 200i9
ces
�oFc�o 9 ry
NOTICE TO OWNER: - FAILURE TO RECG.Z A NOTICE OF COMMENCEMENT MAY RES'L,L,' IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING; CONSULT YOUR
LENDER OR ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. EXEMPT: A/C -
'HEAT REPLACEMENT WITH CONTRACT UNDER $5,000.
INSTRUCTIONS
Please complete all information in the space provided. All information must be printed (use black or blue ink
only) or. typed. This roof permit application is to be used only for those activities that are not otherwise included
under a primary building. permit. This application may not be used for any activity that includes structural
alteration. Building activities involving structural: alteration; in addition to the roof -work, must. be permitted
through the regular building permit review process. The information to be provided with this application
includes:
1. Location/Site Address
Indicate the street address or general location of the
property where the building activity is takirig"place
2. Parcel ID Numlier- Indicate the tax identification number of the property where
the building activity. is taking place.
3. Description of Projector Work Activity Briefly describe the building activity to take place.
4. Total Roof Area
5. Type of Roof
6: Owner Information
7. Contractor Information..
8.. Value of Construction
Indicate total roof area to be affected by this permit. Also
indicate the pitch of the roof,expressed as a standard ratio
of run rise.
Indicate the type of roof being repaired of resurfaced..
Indicate the name and address of the owner of the property.
on which building activity is taking place.
Indicate the State of Florida registration number (if
applicable), St. Lucie County contractor license number and
the name of the business doing the work.
Indicate the total value of the work to take place. Total cost
of construction includes all material and labor costs
associated with the building/construetion activity:
Construction value -is used to determine the permit fee. St.
Lucie County reserves the right to question and/or modify
the indicated value of construction- if it is demonstrated that
the submitted figures are not consistent with similar types
of construction.
This application can be submitted to St. Lucie :County Building and Zoning, 2300 Virginia Avenue, Fort Pierce,
FL 34982. All permit applications must be filled out completely before submission. No applications will be
accepted for processing after 4:30 P.M. For assistance in completing this application, please call (772)
462-1553, during regular office hours (8:00 AM - 5:00 PM), Monday through Friday.
Upon issuance of this permit, required inspections can be scheduled by calling (772) 462-1261.
St. Lucie County Roof Permit Application rev. 7118/05 dmg
EDWIN M. FRY,
Jr.,
CLERK OF
THE CIRCUIT
FILE # 3113816
AFfEltRFCp
OR
IN[•.RF'rtra���
BOOK 2�'— —',
PAGE 2880
Gary 11=0 Roofioq
881•,A 8W Ltlkehurat Or.
mmmaMMUL Port at Lucia FL 34883
C SAINT LUCIE COUNTY
�7 at 01
E Ci NTi''�_.)
THIS 70 CF-R T IFY THAT THIS IS A
'TRUE AN1)] 6€mEcTt0Py 0FTFI
DRIGINAL.
EuW iN 7 .. FfiY,
By,
:07 PM
`.i
ar . resrnW nor rranrrfiog j,,p
NOTICE OF CO)VIl�NCEMEIy'I' The undersigned hereby given notice that imptnvement will be made to certain teal
Florida statutes the following information is provided in the Notice of coumnain red PmP�Y. and m accordance with Chapter 7I3,
PROPERTY (Legal
) L-hh a, - -
DESCRIPTION OF
3. OWNER
d. Name and address of fee simple titleholder
5.
6. LENDER'S NAME, ADDRESS AND PHONE NU11t03$R;
7. Persons within the State of Florida designated by Section 713.13 (1)(a) 7., Florida Statutes: Owner upon whom notices or other documents may be served as provided by
NAME, ADDRESS AND PHONE NUMBER:
8. In addition to himself or herself, Owner designates the following to receive a 713.13 (1)(h), Florida Statutes: copy of the Lienor's Notice as provided in Section
NAME, ADDRESS AND PHONE NUMBER:
9. Expiration date of notice specified) of commencement (the expiration date is I year from the date of recording unless a different date is
_ .
and street addwss) TAX FOLIO NUMBER: �� �S !
fAAV-T r� 2 `1 ----
c. interest in property.
Signature of OvAer or Print Name and Provide Signatory's Ti�pi@i>�e Owner's Authorized O icer/Director/Psrtner/Manager . •••• LYNN MARZO
* * MY COMMISSION i DD 306715
State of Florida EXPIRES: Aprf7 5, 2MB
_ 1 1 � � �44a F�oa��' Bonded ThN Budgx4 pola�p Se�Yites
County of may=--` '_"`
The foregoing instrument w owledged before me this d of��
By q �' 20_,
as
_ane of peiso
�^ (Type ofaumorlty.. e.g. er. Owner, offictrustee, attomey in fact)
ame of party on Wholf of whom instrument was ex etatbed) Personally Known or produced the following type of ID:
rn�c LYNN
*ipt� �� * MYr..n .. :: t a141i6715
(Prince ame of Not ?unl 4 t
6
ary Public) (Sign of Notary Pabli) (Seal) ''Fa F. ?` A,u:
Under penalties of perjury. I declare that I have read the foregoing and that the
belief (section 92.525, Florida Smutes). facts in it are true to the hest of my knowledge and
Signature(s) of Owner() or Owner(s)' Authorized Offlcer/Dlreetor/PartoedMansger who signed above.
By:''/�, �4fji•x
Rev. MnonwTpr Sigaatttne). (Printed Name)
ILE
M I A M I•DA COPY
BUILDING CODE COMPLIANCE OFFICE (BCCO)
PRODUCT CONTROL DIVISION
MIAMI-DADE COUNTY, FLORIDA
METRO-DADE FLAGLER BUILDING
140 WEST FLAGLER STREET, SUITE 1603
MIAMI, FLORIDA 33130-1563
(305) 375-2901 FAX (305) 375-2908
Owens Corning
'1105 PWS Aflo ALL pRopOSED9YOI�!(
One Owens Corning Parkway
ARE SUMCT TO ANY CORRECTION$ =`
Toledo, OH 43659
REQUIRED BY FIELD INSPECTORS THAT A
SCOPE:
MAY RE NECESSARY IN ORDER TO -:
This NOA is being issued under
the applicable rules and regulations governing the use of constructitpkg
on inatenaT.
The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product
Review Committee to be used in
Miami Dade County and other areas where allowed by the Authority Having
Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The BCCO (In Miami Dade County) and/or
the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for
quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer
will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such
product or material within their jurisdiction. BCCO reserves the right to revoke this acceptance, if it is
determined by BCCO that this product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code,
including the High Velocity Hurricane Zone.
fi ridg RPe O
DESCRIPTION-. OKA_
LABELING: Each unit shall bear a permanent label with the manufacturers name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by
the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall
be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA #02-1104.04 and consists of pages 1 through 3.
The submitted documentation was reviewed by Frank Zuloaga; RRC.
ST. LUCIE COU
BUILDING D N
REVI
FOR P CE
REVIEWED BY
DATE - .2 9, O
PLAN AND'PERMIT
MUST BE KEPT ON JOB OR
NO INSPECTION WILL BE MADE
. 1`TOA No 04=65T06
Ex atiom Date:_ I2J12J07
Approval Date:07122%04
Page 1 of 3
ROOFING ASSEMBLY APPROVAL
Category:
Roofing
Sub-Cateeorv:
07310 Asphalt Shingles
Materials
Laminate
Deck Type.
Wood
L SCOPE
This revises a roofing system using Owens Corning Oakridge PRO 30 AR. Asphalt shingles
manufactured by Owens Coning as described in Section 2 of his Notice of Acceptance.
2. PRODUCT DESCRIPTION
Product Dimensions Test Product Description
Specifications
Oakridge PRO 30 AR 13 114 " x 38 3/a" TAS 110
A heavy weight, fiberglass reinforced
Accessory Shingles various proprietary
asphalt shingle.
Accessory shingles for hip, ridge and
starter strip applications.
3. EVIDENCE SUBMITTED:
Test Agency Test Identifier
Test Name/Report Date
Celotex Corp. Testing Services 258495A
TAS 100 06/01/98
Underwriters Laboratories, Inc. 94NK9632
TAS 107 06/30/98
96NK30503
ASTM E 108 10/11/96
98NK16342
ASTM D 3462 05/14/98
OINK44201
UL 997 09/09/02
02NK02878
ASTM D 3462 09/26/02
PRI Asphalt Technologies, Inc. OCF-064-02-01
TAS 100 08/23/02
4. LIMITATIONS
4.1 Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials
Directory for fire ratings of this product.
4.2 Shall not be installed on roof mean heights in excess of 33 ft.
4.3 All products listed herein shall have a quality assurance audit in accordance with the Florida
Building Code and Rule 9B-72 of the Florida Administrative Code.
5. INSTALLATION
5.1 Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
5.2 Flashing shall be in accordance with Roofing Application Standard RAS 115
5.3 The manufacturer shall provide clearly written application instructions.
5.4 Exposure and course layout shall be in compliance with Detail W, attached.
5.5 Nailing shall be in compliance with Detail W, attached.
6. LABELING
6.1 Shingles shall be labeled with the Miami -Dade Logo or the wording "Miami -Dade County
Product Control Approved".
7. BUILDING PERMIT REQUIREMENTS
NOA No.: 04-0510.04
Expiration Date: 12/12/07
Approval Date:07/22/04
Page 2 of 3
J
7.1 Application for building permit shall be accompanied by copies of the following:
7.1.1 This Notice of Acceptance.
7.1.2 Any other documents required by the Building Official or the applicable code in order
to properly evaluate the installation of this system.
8. MANUFACTURING PLANTS
8.1 Jacksonville, FL
8.2 Savannah, GA
I
DETAIL A
DETAIL B
END OF THIS ACCEPTANCE
EXPOSURE
NOA No.: 04-0510.04
nAL
Expiration Date: 12/12/07
Approval Date:07/22/04
Page 3 of 3
ROOFING APPLICATION STANDARD (RAS) No.115
STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION
1. Scope 4.
Underlayment
1.1 This roofing application standard has
4.1
Minimum prescriptive underlayments
been developed to provide a responsive
shall be one of the following, unless oth-
method of complying with the require-
erwise specifically noted in roofing as-
ments of Chapters 15 and 16 (High-Ve-
sembly Product Approval:
locity Hurricane Zones) of the Florida
Building Code, Building while providing
• A double layer of an ASTM D 226,
a prescriptive method of installing asphal-
Type I,with a 19-inch headlap; or
tic shingles.
• A single layer of an ASTM D 226,
type II with a 4-inch headlap; or
A single layer of an ASTM D 2626
2. Definitions
coated base sheet with a 4-inch
headlap.
• All endlaps shall be a minimum of 6
2.1 For definitions of terms used in this appli-
inches.
cation standard, refer to ASTM D 1079
• All valleys shall be woven.
and the Florida Building Code, Building.
4.2
All underlayments shall be fastened with
3. General
minimum 12 gage by 1 `/4 in. corrosion -re-
sistant annular ring shank roofing nails fas-
tened trough minimum 32 gage by 15/8 in.
3.1 Asphaltic shingles shall not be installed
diameter tin caps. Maximum fastener spac-
on roof mean heights .greater than 33 feet,
ing shall be 6 in. o.c. at the laps with two ad -
unless specifically specified in the roof
ditional rows in the field at a maximum
I I assemblies Product Approval. Roof slope
spacing of 12 in. o.c. Nails shall be of suffi-
criteria shall be in accordance with Table
cient length to penetrate through the 9heath-
1515.2.
ing or wood plank a minimum of/,e,in. or
penetrate 1 inch (25 min) or greater thick-.
ness of lumber a minimum of 1 in., except
3.2 Where asphaltic shingles are to be in-
where architectural appearance is to be pre- .
stalled.over insulated roof deck, a suitable
served, in which case a minimum of in.
nailable substrate, in accordance with
nail may be used.
Section 1520.5.7 must be installed over .
the insulation prior to the installation of
approved underlayment and shingles.
4.3
If the underlayment is a self -adhering
membrane; the membrane shall be ap-
plied over a mechanically attached an-
3.3 Asphaltic shingles shall be installed in com-
chor/base sheet attached in compliance
I I pliance with the Product Approval installa-
with this section above. .
tion drawings, but in no case with less than
six approved roofing nails (12 ga. by V/4 in.
corrosion -resistant annular ring shank roof- 5.
Metal Accessories
ing nails) or approved fastening devices
which penetrate through the sheathing or
/16 in.
5.1
All metal accessories shall be in compli-
wood plank a minimum of or pene-
trate a 1 in. or greater thickness of lumber a
ance with Section 1517.E of the Florida I I
minimum of 1 in. except where architec-
Building Code, Building and RAS 111.
tural appearance is to be preserved, in which
case a minimum of 3/4 in. nail may be used.
5.2
Eave and gable drip metal vertical face shall
be a minimum of 11/2 inches and shall ex-
tend down not -less than'/z inch below the
sheathing or other member immediately
FLORIDA BUILDING CODE -TEST PROTOCOLS HVHZ (RAS)115.1
,ar
(RAS) No. 115
t.
6.
contiguous thereto. In all cases, the deck
flange shall be not less than 2 inches in
width. Where required, a continuous clip
(hook strip) shall be installed in compliance
with RAS 111.
5.3 Eave and gable drip metal shall be joined
by a lapped of a minimum of 4 in. and the
entire interior of the joints shall be coated
with approved flashing cement. Eave and
gable drip metal shall be fastened with
minimum 12 gauge annular ring shank
nails at a maximum spacing of 4 in. o.c.
The nails shall be manufactured from
similar and compatible material to the ter-
mination profile. All composite materials
shall be fastened with nonferrous nails.
All metal profiles shall be installed in
compliance with RAS 111.
5.4 Valley metal shall be a minimum 16 in.
wide rolled or preformed material of thick-
ness' in compliance with Section 1517.6 of
the Florida Building Code, Building. Valley
metal shall be set over the underlayment, or
over an optional 18 in. sweat sheet. Fasten
valley metal with minimum 12 gage by 11/4
in. annular ring shank roofing nails of simi-
lar materials 12 in. o.c.1 in. in from each ex-
terior edge. The entire edge of the flange
shall be sealed, covering all nail penetra-
[ions with flashing cement and membrane.
All horizontal laps shall be a minimum of 6
in. and shall be fully embedded with ap-
proved flashing cement. No nails shall be
permitted in the center of the valley.
Shingle Installation
6.1 At all intersections, eaves, rakes, valleys,
and gable ends the shingles and starter strips
shall be set in a minimum 8-in. wide strip of
approved flashing cement. Maximum
thickness of flashing cement shall be 1/8 in.
as excessive use of the cement may cause
blistering, or bleed through. Shingles shall
not extend more than '/4 in. beyond the cave
drip.
6.2 The starter strip may be either a row of
nonlaminated shingles trimmed to the
shingle manufacturer's recommendations
or a strip of mineral -surfaced roll roofing
not less than 7 in.wide.
6.3 If self-sealing shingles are used for the
starter strip, remove the tab portion of
each shingle and position the remaining
strip with the factory -applied adhesive
face up along the eaves. Trim material
from the end of the first shingle in the
starter strip according to manufacturer's
specifications to ensure that the cutouts of
the first course of shingles are not placed
over the starter strip joints. Fasten starter
strips parallel to the eaves along a line
above the.eave line according to manufac-
turer's specifications. Position fasteners
to insure they will not be exposed under
the cutouts in the first course.
6.4 For shingles without a self-sealing strip
the tabs shall be removed and approved
flashing cement shall be applied in spots,
approximately the size of a quarter at the
corner of each tab of the first course.
Starter shingles shall be nailed along a
line not greater than 4 in. above the cave
line nailing not greater than 6 in. o.c. En-
sure that the cutouts of the first course are
not placed over the starter strip joints.
6.5 If roll roofing is used for the starter strip,
nail along a line not greater than 4 inches
above the cave line nailing not greater
than 12 inches o.c. Approved flashing ce-
ment shall be applied as noted above for
nonsealing shingle starter. If more than
one piece of roll roofing must be used, the
end joint shall be butted. Joints shall be
staggered with succeeding shingle joints,
and the number of starter joints shall be
kept to a minimum.
6.6 First course shall be laid straight, check-
ing it regularly during application against
a horizontal chalk line. A few vertical
chalk lines aligned with the ends of shin-
gl,es in the first course will ensure proper
alignment of cutouts. A shingle hatchet is
an acceptable alternative to the use of suc-
ceeding chalk lines. The first course starts
with a full shingle, while succeeding
courses shall be installed in strict compli-
ance with the shingle manufacturers'
Product Approval course layout detail.
6.7 Rake and valley courses shall be termi-
nated with shingles not less than 12 in. in
length. To obtain the correct exposure for
square -tab strip shingles, align the butts
(RAS) 115.2 FLORIDA BUILDING CODE — TEST PROTOCOLS HVHZ
r � �
(RAS) No. 115
with the top of the cutouts in the course
below. Install no -cutout shingles and
those with variable butt lines according to
the manufacturer's directions to obtain PROPERLY DRIVEN
correct exposure.
NOTE: Follow manufacturer's .instruc-
tions concerning shingle align-
ment. See "Exposure, Course
Layout, and Fastening Detail" in
shingle manufacturer's Product
Approval.
7. Fastening
IMPROPERLY DRIVEN
UNDERORNEN OVERORM CROONED
ASPHALT
SHINGLES
UNDERLAYMENT
DETAIL A
7.1 Use six approved nails per shingle. Place
8 .2 Open valley: Snap two chalk lines, one on
each side of the valley centerline over the
the fasteners in strict compliance with
full length of the valley flashing. Locate the
shingle manufacturers Product Approval
I
upper ends of the chalk lines 6 in. apart in
course layout, fastening details.
the center of valley at the ridge (i.e., three
inches to either.side of the valley center-
7.2 Align the shingles properly to avoid ex-
line). The lower ends should diverge from
each other a minimum of /8 in. per linear
posing fasteners in the course below.
foot of valley length, (i. e., for an eight foot
Drive the fasteners straight and do not
long valley the chalk lines shall be 7 inches
break the shingle surface with the fastener
apart at the eaves).
head. Do not drive fasteners into knot
holes or cracks in the roof deck. Repair
faulty fastening immediately. If fastener
As shingles are applied toward the valley,
I I is improperly driven or exposed, remove
trim the last shingle in each course to fit
the fastener and repair the hole in the shin-
on the chalk line. Never use a shingle
gle with approved flashing cement or re-
trimmed to less than 12 inches in length to
place the entire shingle.
finish a course running into a valley. If
necessary, trim a tab off the adjacent shin-
gle in the same course to allow a longer
7.3 Do not nail into or above factory -applied
portion to be used, trim 1 inch on a 45-de-
adhesives. Ensure no cutout or end joint is
gree angle from the upper corner to direct
less than 2 inches from a nail in an under-
water into the valley and prevent it from.
lying course. Start nailing from the end
penetrating between the courses. Finally,
nearest the shingle just laid and proceed
to form a tight seal, cement the shingle to
across. Do not attempt to realign a shingle
the valley, lining with a minimum
by shifting the free end after two nails are
eight -inch width of asphalt flashing ce-
in place. Drive nails straight so, that the
ment. There should be no exposed nails
edge of the nail head does not cut into the
along the valley flashing.
shingle. Nail heads should be driven flush
with the shingle surface. Fasteners shall
not be improperly driven (see Detail A).
8.3 Closed cut valley: With valley flashings
already in place, apply the first course of
shingles along the eaves of one of the in-
tersecting roof planes and across the val-
8. Valleys
ley. For proper flow of water over the
trimmed shingle, always start applying
the shingles on the roof plane that has the
8.1 Valleys may be applied in open, closed or
lower slope or lesser height. Extend the
end shingle at least twelve inches onto the
woven fashion. Valley metal shall be in
adjoining roof. Do not make a joint in the
compliance with Section 5.4.
valley. If a shingle falls short, add in one
or two tab sections so that joint occurs
FLORIDA BUILDING CODE — TEST PROTOCOLS HVHZ (RAS) 115.3
(RAS) No. 115
outside the line of the valley. Apply suc-
ceeding courses in the same manner, ex-
tending them across the valley and onto
the adjoining roof. Press shingle tightly
into the valley. Use normal shingle fasten-
ing methods except that no nails should be
within six inches of the valley centerline
and two nails shall be placed at the end of
each shingle crossing the valley. Snap a
chalk line two inches from the centerline
of the valley on the under -shingled side.
Then apply shingles on the under shingled
side. Trim the shingles as they are being
installed to the chalk lines to ensure a neat
installation. Trim one inch on a 45-degree
angle from the upper corner of each shin-
gle upon installation. This will direct wa-
ter into the valley. Finally embed each end
shingle in a 3-inch (76 mm) wide strip of
flashing cement.
8.4 Woven valley: The valley flashing should
already be in place as described earlier.
Shingles on the intersecting roof surfaces
may be applied toward the valley from
both roof areas simultaneously or each
roof area may be worked separately up to
a point about three feet from the center of
the valley and the gap closed later. Re-
gardless of which procedure is followed;
apply the first course, along the eaves of
one roof area up to and over the valley
with the last shingle extending at least 12
inches onto the intersecting roof. Then
apply the first course of the intersecting
roof along the eaves and extend it across
the valley over the top of the shingle al-
ready crossing the valley and at least 12
inches onto the other surface. Apply suc-
cessive courses alternately from the ad-
joining areas, weaving the valley shingle
over the other. Press each shingle tightly
into the valley. Use normal shingle fasten-
ing methods except that no nails should be
within six inches of the valley centerline
and two nails shall be placed at the end of
each shingle crossing the valley.
9. Flashing
9.2 Option A: All wall abutments shall be
flashed with a minimum of 4 in. by 5 in.
"L" metal flashings of materials and
thickness in accordance with Section
1517.6 of the Florida Building Code,
Building. The metal "L" flashing shall be
set in approved flashing cement and set
flush to base of wall and over
underlayment (see Detail B). Both hori-
zontal and vertical metal flanges shall be
fastened 6 inches o.c. with approved fas-
teners. Fastening shall be in accordance
with RAS 111. All laps shall be a mini-
mum of 4 inches fully sealed in approved
flashing cement. Flashing shall start at the
lower portion of the roof to ensure wa-
ter -shedding capabilities of all metal laps.
The entire edge of the metal flashing shall
be sealed covering all nail penetrations
with approved flashing cement and mem-
brane. The metal "L" flashing shall be
counter flashed. All metal counter flash-
ing shall be installed in accordance with
RAS 111.
9.3 Option B: Roof planes that butt against
Vertical walls shall be step flashed with 10
in. long metal shingles which are 2 in.
wider than the exposed face of the roofing
shingles (see Detail Q. Place the first
flashing unit over the end of the starter
strip and position it so that the tab of the
end shingle in the first course covers it
completely. Secure the horizontal arm to
the roof with two approved roofing nails.
Do not nail flashing to the wall; settling of
the roof could damage the seal. Apply the
9.1 All shingles that butt against wall flash-
ings shall be step bulled with approved
flashing cement a minimum of eight DETAIL B
inches, and all roof planes that butt
against vertical walls shall be flashed in
one of the following manners:
(RAS) 115.4 FLORIDA BUILDING CODE — TEST PROTOCOLS HVHZ
(RAS) No. 115
FLASHING PLACED UPSLOPE FROM
EXPOSED EDGE OF SHINGLE
EXTENDING 4 INCHES OVER
UNDERLYING SHINGLE AND
4 INCHES UP VERTICAL WALL
MINIMUM 2-INCH HEADLAP UNDERLAYMENT TURNED UP
VERTICAL WALLS MINIMUM
4 INCHES
DETAIL C
first course of shingles up to the wall. Po-
sition the second step flashing strip over
the end shingle in the first course 5 inches
up from the butt.so that the tab of the end
shingle in the second course covers it
completely. Fasten the horizontal arm to
the roof. The second course of shingles
follows, the end is flashed as in the pre-
ceding courses and so on to the top of the
intersection. Bring siding or other wall
treatment down over the vertical sections
of the step flashing to serve as cap flash=
ing. Wall treatment or cap flashing shall
terminate a minimum of 1 in. above the
roofline. All metal counter flashing shall
be installed in accordance with RAS 111.
9.4 Head/apron flashing at all vertical end
walls: Apply shingles up the roof until a
course must be trimmed to fit at the base
of the vertical wall. Adjust the exposure
slightly in the previous two courses so that
the last course is at least 8 inches wide.
Apply a continuous piece of metal flash-
ing over the last course of shingles by em-
bedding it in approved flashing cement
and nailing it to the roof. The metal flash-
ing strip shall be bent to extend at least 5
inches up the vertical wall and at least 4
inches onto the last shingle course. Do not
......................
nail the strip to the wall. Apply an addi-
tional row of shingles over the metal
flashing strip, trimmed to the width of the
strip. Bring siding down over the vertical
flashing to serve as cap flashing. Wall
treatment or cap flashing shall terminate a
minimum of 1 in. above the roofline. Do
not nail siding into the vertical flashing. If
the vertical front wall meets a side wall, as
in dormer construction cut flashing so that
it extends at least 7 inches around the cor-
ner. Continue up the side wall with step
flashing as detailed above.
10. Soil Stacks and Vent Pipes
10.1 Apply shingles up to the vent pipe. Cut a
hole in a shingle to go over the pipe and set
the shingle in ASTM D 4586 flashing ce-
ment. A preformed flashing flange that
fits snugly over the pipe is then placed
over the shingle and vent pipe and set in
approved flashing cement. Place the
flange over the pipe to lay flat on the shin-
gle below. After the flashing is in place,
resume shingle application. Cut shingles
in successive courses to fit around the
FLORIDA BUILDING CODE — TEST PROTOCOLS HVHZ
(RAS) 115.5
(RAS) No. 115�
11.
pipe and embed them in approved flash- overlap the flashing in an 8" bed of ap-
ing cement where they overlap the flange. proved flashing cement. Place the rear
Avoid excessive use of cement as it may base flashing over the cricket and the, high
cause blistering. Do not drive fasteners side of the chimney. Chimney crickets
close to the pipe. The lower part of the shall be waterproofed in compliance with
flange shall overlap the lower shingles the shingle manufacturers published liter -
and the side and upper shingles shall over- ature. All chimney flashings shall be
lap the flange. countered flashed. Metal counter flashing
shall be in accordance with RAS 111.
10.2 For ventilator and exhaust stacks, follow
the same procedure, but bring the shingles 12•
up to the pipe from both sides and bend
the flange over the ridge to lie in both roof
planes, overlapping the roof shingles at all
points. Ridge shingles are then positioned
to cover the flange. Embed the ridge shin-
gles in approved flashing cement where
they overlap the flange. Roof ventilators
shall be flashed in accordance with'venti-
lators Product Approval.
d
Chimneys
11.1 Chimneys shall be flashed with a
two-piece base and cap flashing to allow
for differential movement. Apply shin-
gles up to the front edge of the chimney
before any flashings are installed. Apply a
coat of ASTM D 41 asphalt primer if the
chimney is constructed of masonry or
metal to seal the surface and to provide
good adhesion to all points where flashing
cement will later be applied.
11.2 Install flashing in accordance with Sec-
tion 9 above. Apply the base flashing to
the low side of the chimney first. Bend the
base flashing so that the lower section ex-
tends at a minimum of 4 inches over the
shingles and the upper section extends a
minimum of 12 inches up the vertical face
of the chimney. Work the flashing firmly
and smoothly into the joint between the
shingles and chimney. Set both the roof
and chimney overlaps in approved flash-
ing cement placed over the shingles and
on the chimney face. The flashing shall be
secured in accordance with RAS 111. Use
metal step flashing for the sides of the
chimney, positioning the units in the same
manner as flashing on a vertical side wall,
in accordance with Details A and B
herein. Secure each flashing unit to the
masonry with approved flashing cement
and to the deck with approved nails. Em-
bed the end shingles in each course that
Hips and Ridges
12.1 Apply premanufactured hip and ridge
shingle components or cut hip and ridge
shingles from manufacturer's strip shin-
gles. Lay hip and ridge away from prevail-
ing wind. Insure all fasteners are covered.
Exposure shall not exceed 5 inches. Taper
the lap portion of each cap shingle slightly
so that it is narrower than the exposed por-
tion.
(RAS) 115.6 FLORIDA BUILDING CODE — TEST PROTOCOLS HVHZ
Code Compliance Division
2300 Virginia Avenue
Ft. Pierce, FL 34982
Phone: (772) 462-1553 Fax: (772) 462-1148
http://stl u cieco. g ov/ce
BUILDING PERMIT
Issued: 09/27/2007 Conf #; 700 Permit #: SLC- 0709-0360
Job Location: 3712 DORAL CT City: PORT ST LUCIE
Permit Type: Roof
Job Description: TEAR OFF AND REROOF FIBERGLASS SHINGLES 1800 SQ FT 2/12P
Subdiv: Savanna Club Plat Phase Three
Lot: 32 Block: 43* Parcel: 3425-705-0168-00013
Setbacks Left: Right: Front: Rear: Zoning: PUD
Number of Units: 1.00 Floors: 1 Buildings: 1 Square Footage: 0.00
Minimum Floor Elevation: Flood Map: Flood Zone: Elev:
Job Value: $ 4,300.00
Page 1
Permit holder acknowledges through acceptance of this permit that separate permits must be obtained as required by the Florida Building Code
including those for all electric, plumbing, mechanical, roofing, and structural work. Further, he/she acknowledges responsibility to comply with all
requirements of the 2004 Florida Building Code.
NOTICE: In addition to the requirements in this permit, there may be additional restrictions applicable to this property that may be found in the
records of this County, and there may be additional permits required from other governmental entities such as water management districts, state
agencies, or federal agencies. s:553.79(10), F.S.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR
BUILDING IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. s.713.135, F.S.
Christopher Lestrange
�'• a7 0 7
Building Official Date
For Automated Inspections, Call (772) 462-1261
For Questions, Call (772) 462-2172
St. Lucie County Land Development Code Section 11.05.01 (A) (2) states; Building Permits shall expire and
become null and void if work authorized by such Building Permit is not commenced, having called for and
received a satisfactory inspection, within six (6) months from the date of issuance of the permit, or if the
work is not completed within 18 months (permit by contractor) or 24 months (permit by owner) from the date
of issuance of the Building Permit.
Code Compliance Division
2300 Virginia Avenue
Ft. Pierce, FL 34982
Phone: (772) 462-1553 Fax: (772) 462-2522
http://stiucieco.gov/ce
Date: 27 September 2007
Job Address: 3712 DORAL CT
Received By: humphreya
Paid With: CK
Paid By: GARY MARZO INC
Buildmg'
Receipt',
Sign:
Receipt M
0000057730 -
'ermit Number:
SLC- 0709-0360
Amount:
$180.00
�redit Card Number:
Check Number:
2629