Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSI La►C: !T 4,J1 /I r CC 1/UC: a v-v v I necelp«> -/ - S- f Yermlt p /(/ y -� v _ � St. Lucie County Building -< 2300 Virginia Avenue -. Ft. Pierce, FL 34982-5652 ORIOp' • TeL 772-462-1553 1.2� APPLICATION FOR ROOF PERMIT / 06• 9 S EV�ltSE SIDE FOR INCou—H- 2.CTIONS I. Location/Site Address:.15 '' II rrll. Q 'Parcel ID. Number: 7`t H -- 55V v v Office Use Section Township' Range .Ma Pa e• -Zoning Land Use Initials Only .. s .40e-1ZyL—M.... 3. Description of Project or Work Activity: 4. Total Roof Area (square feet): 6. Type of Roof: I Fiberglass Shingle Tar & Gravel 5. Roof Pitch: ❑Barrel/Tile Ceramic ❑Modified Bitumen ❑ Wood Shake `Shingle. ❑ Metal NFD sx, 4 y�/BY All Commercial Roofing Requires Design by an Engineer or Architect (two Sets) ❑ Other (specify) N.O.A — Product Approval required for All Types of Roofing Material 7. Owner Information 8. Contractor Information Name: d� ��&k Q��� FL Reg/Cert#: CC C07-3 Address: l �� ��U4� CoufLCounty Cert#: City: U .Q, State: L Business Name: arm �C Zip: q9.4- Phone: � SPhone�l -I& JOFax `ho e)8�-1" 9. Value of Construction: $ Note: Dry -in and.Final"Inspection Required. Additional. inspection may- be.required per Product Approval J OWNER'S -AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in compliance with all applicable laws regulating construction and zoning. I Oaf Z- 0 NfisA `1- PRINT Q ALIFIERS/OWNERS NAME SIN TURF OF Q LIFIER/OWNER STAO,CYOl _ LUQ� ACKNOWLEDGED BEFORE ME THIS" V 1 DAY OF 21 BY WHO-IS.PERSONALLY KNOWN TO ME OR WHO HAS PRODUCED.:_,. I AS IDENTIFICATION NOTARY St. Lucie County Roof Permit Application rev. 7/18/05 dmg I LI�CL ` (seal) tj TYPE OR PRINT NAME OF NOTARY. RN PUg COMMISSION NUMBER � MY,COMMISSION4 DD 420650 * �* EXPIRES: April - 2609 ram= r:l , �Pl�TE� FLpP��P Bonded Thru Budget Notary Services NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. EXEMPT: A/C - HEAT REPLACEMENT WITH CONTRACT UNDER $5,000. INSTRUCTIONS Please complete all information in the space provided. All information must be printed (use black or blue ink - only) or. typed. This roof permit application is to be used only for those activities that are not otherwise included under a primary building. permit. This, application may not be used for any activity that includes structural alteration. Buildingactivities involving structural: alteration; in addition to the roof -work, must. be permitted through the regular building permit review process. The information to be provided -with this application includes: 1. Location/Site Address Indicate the street address or general location of the property where the building activity, is taking'place 2. ParcelID Number - Indicate the tax identification number of the property where . the building activity. is taking place. 3. Description of Project or Work Activity Briefly describe the building activity to take place. 4. Total'Roof Area Indicate total roof area to be affected by this permit. Also indicate the pitch of the roof, expressed as a standard ratio of run rise. 5. Type of Roof Indicate the type of roof being repaired or resurfaced. 6: Owner Information Indicate the name and address of the owner of the property.. on which building activity is taking place. 7. Contractor Information. Indicate the State of Florida registration number (if applicable), St. Lucie County contractor license number and the name of the business. doing the work. 8.. Value of Construction Indicate the total value of the work to take place. Total cost of construction includes all 1paterial and labor costs associated with the buildingko'nstruction activity:` Construction value is used to determine the permit -fee. t: = . Lucie County reserves the right to question and/or modify the indicated value of consttuctioii- if it is demonstrated that S the submitted figures are not corisistent with similar types of construction. This application can be submitted to St. Lucie County Building and Zoning, 2300 Virginia Avenue, Fort Pierce, FL 34982. All permit applications must be filled out completely before submission. Not applications will be 4accepted for processing after 4:30 P.M-. For assistance in completing this application, please call (772) �62-1553, during regular office hours (8:00 AM - 5:00 PM), Monday through Friday. f Upon issuance of this permit, required inspections can be scheduled by calling (772) -462-1261. St. Lucie County Roof Permit Application rev. 7/18/05-dmg EDWIN M. FRY, Jr., CLERK ()— �,m CIRCUIT PILE # 3113817 OR BOOK 21_ PAGE 1,881, GarY Marro Rooft M-A 8W L.akehunt or. Port St LuCle FL S48S3 COURT — SAINT LUCTF COUNTY Recorded 09/27/l at 01: STATE OF F")"'DA T. LUCIE COUNTY il THIS TO CERTIFY THAT THIS IS A CA CORRECT CORM OF THE R1(31WAL. . C-DWI . Fl. , NOTICE F The undersigned here Florida statutes the folio g InfoRmiatioa Lm�vement Will be made to c�aWn realprovided in the Notice of commencement. and in accordance with Chapter 713, 1. DESCRIPTION OF PROPERTY (Legal description and street address) TAX FOLIO NUMBER: �q SUBDIVISION' {�ou,A erns rw ( AI - — _ — 3- t — � (`n 07 PM 2.. GENERAL DESCRIPTION OF I OWNER INFORMATION: d^Name and address of fee simple titleholder (ifother &an L'; 's PHONE NUMBE 5. SURETY'S NAME, ADDRESS AND PRONE 1 NUMBER AND BOND AMOUNT. 6. LENDER'S NAME, ADDRESS AND PRONE NUMBER. 7. Persons within the State of Florida designated by Owner ups whom natias outer doarmeats rna Section 713.13 (1)(a) 7., Florida Statutes: Y served as provided by NAME, ADDRESS AND PHONE NUMBER. 8. In addition to himself or herself; Owner designates the following to receive a copy of the Lienor's Notice as provided in Section 713.13 (1)(b), Florida Statutes: NAME, ADDRESS AND PHONE NUMBER: 9. Expiration date of notice of commencem20 t (the etpirad date I y� from fife dais of racer dirt specified) g tiojew a different date is Print Name and Provide Signabury's TittdoW ee State ofFlMLL� County of x The foregoing t strument wws admowl before me this 2001 By of eofpers n) ' For b Y crype °f mrthority.,e.g.Owner, officer, trustee, attorney is fact) (Name of party on behalf instrumwt was executed) Personally Known4 or produced 8WIf 1lowin tyre 1]D- +°��o g _CYN f ID• * MYCOMMISSION#=06715 EXPIRES:Apti15,2W8 (prince ameofNotarypublio) '�a,F " SondedThruBudgetNafrryServicas r o Notary Publi (�Seul) Under penalties of pery'ury, I declare that I have read the foregoing and that the facts in it are true to the best of my knowledge and belief (section 92,525, Florida Statutes): Slgnature(s) of Owner(s) or Owner(sy Authorized Otlleer/Dlred0rjpartnedManager Who SIned above: By: —} 13y ,�,,. omormozp (SignaUrt,e) (Printed Name) 1-- ..M)0-q ' �'IE PUNS AND ALL PROPOSED WORK -� Amin SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT ,HIAY LOP NEC0T4ARY IN ORDER TO MM I� DADS 9010P Y WITH ¢�, AMMA N 99958a MIAMI.DADE COUNTY, FLORIDA METRO -DADS FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE (BCCO) 140 WEST FLAGLER STREET, SUITE 1603 PRODUCT CONTROL DIVISION (305) 375-2 0� FLORIDA 1FAX (05) 3755-2908 Owens Corning FILECO !�s ww"i w ► tug i an6nij vn mi inw ins One Owens Corning Parkway "' f �SU1Y OF THE Toledo, OH 43659 PrWRACTO'R V RD SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committee to be used in. Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The BCCO (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BCCO reserves the right to revoke this acceptance, if it is determined by BCCO that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Oakridge PRO 40 AR, Oakridge PRO 50 AR, and burat�miuin LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA #05-1213.02 and consists of pages 1 through 6. The submitted documentation was reviewed by Alex Tigera. .`�el,� ST. LUCIE BUILDING FOR 1 REVIEWED BY DATE PANS D PERMIT MUST BE KEPT ON JOB OR NO (INSPECTION WILL BE MADE ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -Category: 07310 Asphalt Shingles Materials Laminate Deck Type: Wood 1. SCOPE This revises a roofing system using Owens Corning Oakridge PRO 40 AR, Oakridge PRO 50 AR, and Duration Premium. Asphalt shingles manufactured by Owens Coming as described in Section 2 of his Notice of Acceptance. 2. PRODUCT DESCRIPTION Product Dimensions Test Product Description Specifications Oakridge PRO 40 AR 131/4" x 39'/8" Oakridge PRO 50 AR 131/4" x 39'/8" Duration Pfee mulm Accessory Shingles various 3. EVIDENCE SUBMITTED: Test Agency Celotex Corp. Testing Service PRI Asphalt Technologies, Inc. Underwriters Laboratories, Inc. TAS 110 A heavy weight, fiberglass reinforced four tab asphalt shingle. TAS 110 A heavy weight, fiberglass reinforced rAS,`1'10t four tab asphalt shingle Q heavy &g-g�ht, fiberglass reinforces our ta} a 'p lrshmgle with:large nail -�. _ - proprietary Accessory shingles for hip, ridge and starter strip applications. Test Identifier 258495B OCF-069-02-01 OCF-071-02-01 OCF-096-02-01 OCF-097-02-01 OCF-075-02-01 OCF-083-02-01 94NK9632 03NK04954 03NK04954 03NK21814 05CA38930 04NK06517 03NK0495 03NK33481 06CA41119 96NK30503 07CA02026 Test Name/Report TAS 100 TAS 100 TAS 100 TAS-100 TAS-100 TAS 100 TAS 100 TAS 107 TAS 107 TAS 107 TAS 107 TAS 107 TAS 107 UL 997 TAS 107 TAS 107 ASTM E 108 ASTM D 3462 Date 06/01/98 08/21/03 08/22/03 11/30/06 11/30/06 03/01/04 09/24/04 i t 1 NOA No.: 0-0306.04 Expiration Date: 0/19/1 Approval Date: 05r 0/077 Page 2 of 6 `r - 07/01/98 03/28/03 03/11/03 08/28/03 10/24/05 05/04/04 03/06/03 12/02/03 12/07/06 10/11/96 01/26/07 98NK16342 ASTM D 3462 05/14/98 98NK24243 ASTM D 3462 09/03/98 OONK14644 ASTM D 3462 01/29/01. 02NK02878 ASTM D 3462 10/15/03 02NK02878 ASTM D 3462 10/20/03 98NK38907 ASTM D 3462 12/14/98 4. LIMITATIONS 4.1 Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 4.2 Shall not be installed on roof mean heights in excess of 33 ft. 4.3 All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B-72 of the Florida Administrative Code. 5. INSTALLATION 5.1 Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 5.2 Flashing shall be in accordance with Roofing Application Standard RAS 115 5:3 The manufacturer shall provide clearly written application instructions. 5.4 Exposure and course layout shall be in compliance with Detail 'A', attached. 5.5 Nailing shall be in compliance with Detail 'B' and Detail `C', attached. 6. LABELING 6.1 Shingles shall be labeled with the Miami -Dade Logo or the wording "Miami Dade County Product Control Approved". 7. BUILDING PERMIT REQUIREMENTS 7.1 Application for building permit shall be accompanied by copies of the following: 7.1.1 This Notice of Acceptance. 7.1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. 8. MANUFACTURING PLANTS Oakrid a PRO 40 AR Oakrid a PRO 50 AR Duration Premium Savannah, GA Savannah, GA Savannah, GA Medina, OH Medina, OH Jacksonville, FL Jacksonville, FL Jacksonville, FL Houston, TX Houston, TX Denver, CO Denver, CO Portland, OR Portland, OR Irving, TX © NOA No.: 07-0306.04- Expiration Date: 07/19/11 Ap roval Date: 05/10/07 Page3of6�'�. __ r 13-1/4" OF ROOF FIRST COURSE DETAIL A DETAIL B OWENS CORNING OAKRIDGE PRO 50 AR OAKRIDGE PRO 40 AR I a 1111 —1 r�2" ---t 2" i11 " M. I. —1 " 5 5/8" EXPOSURE NOA No.: 07-0306.04 Expiration Date: 07/19/11j Approval Date: 05/16/071 age 4 of 6 { SureNail Fastening ai Ows Area de fijacion SureN U 7�i A �H. Fastening area Area de fijacion Fastening area for Mansard or Steep Slope Area de fijacion pars mansardas o pendientes agudas Li "Rk 5 8" Exposure 5 e" de exposition SureNall fastening area width Area de clavos SureNf ail y 5 e" Expos in 5 e" de exposicion SureNall fastening area width Area de clavos SureNall Nails Clavos MAXIMUM SLOPE 21:12 Nails Clavos ON SLOPES EXCEEDING 21:12 END OF THIS ACCEPTANCE 5 e" Exposure 5 e" de exposicion Mansard and Steep Slope fasten between SureNall area and top of cut out. lansa►da o pendientes gudas filadas enre of rea SureNail y la parts uperlor del recorte, SureNaii fastening area width Area do clavos SureNall 5 e' Exposure 5 8" de exposicion NOA No.: 07-0306.04 ration Date: 019/11 p4val'Date ,05/10/07 Page 6 of 6 D, ROOFING APPLICATION STANDARD (RAS) No.115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION 1. Scope 4. Underlayment 1.1 This roofing application standard has 4.1 Minimum prescriptive underlayments been developed to provide a responsive shall be one of the following, unless oth- method of complying with the require- erwise specifically noted in ,roofing as- ments of Chapters 15 and 16 (High-Ve- sembly Product Approval: locity Hurricane Zones) of the Florida Building Code, Building while providing • A double layer of an ASTM D 226; a prescriptive method of installing asphal- Type I,with a 19-inch headlap; or tic shingles. • A single layer of an ASTM D 226, type II with a 4-inch headlap; or • A single layer of an ASTM D 2626 2. Definitions coated base sheet with a 4-inch headlap. • All endlaps shall be a minimum of 6 2.1 For definitions of terms used in this appli- inches. cation standard, refer to ASTM D 1079 • All valleys shall be woven. and the Florida Building Code, Building. 4.2 All underlayments shall be fastened with 3. General minimum 12 gage by 11/4 in. corrosion -re- sistant annular ring shank roofing nails fas- tened trough minimum 32 gage by 1518 in. 3.1 Asphaltic shingles shall not be installed diameter tin caps. Maximum fastener spac- on roof mean heights greater than 33 feet, ing shall be 6 in. o.c. at the laps with two ad - unless specifically specified in the roof ditional rows in the field at a maximum I I assemblies Product Approval. Roof slope spacing of 12 in. o.c. Nails shall be of suffi- criteria shall be in accordance with Table cient length to penetrate through the sheath- 1515.2. ing or wood plank a minimum'of'3/16 in. or penetrate 1 inch (25 mm) or greater thick- ness of lumber a minimum of 1 in., except 3.2 Where asphaltic shingles are to be in- where architectural appearance is to be pre- . stalled over insulated roof deck, a suitable served, in which case a minimum of 3/4 in. nailable substrate, in accordance with nail may be used. Section 1520.5.7 must be installed over . the insulation prior to the installation of approved underlayment and shingles. 4.3 If the underlayment is a self -adhering membrane; the membrane shall be ap- plied over a mechanically attached an- 3.3 Asphaltic shingles shall be installed in coin- chor/base sheet attached in compliance I I pliance with the Product Approval installa- with this section above. tion drawings, but in no case with less than six approved roofing nails (12 ga. by 1 `/a in. corrosion -resistant annular ring shank roof- 5. Metal Accessories ing nails) or approved fastening devices which penetrate through the sheathing or 5.1 All metal accessories shall be in compli- wood plank a minimum Of /16 in. or pene- ance with Section 1517.E of the Florida trate a 1 in. or greater thickness of lumber a Building Code, Building and RAS 111. I I minimum of 1 in. except where architec- tural appearance is to be preserved, in which case a minimum of 3/4 in. nail may be used. 5.2 Eave and gable drip metal vertical face shall be a minimum of 11/2 inches and shall ex- tend down not less than '/2 inch below the sheathing or other member immediately FLORIDA BUILDING CODE -TEST PROTOCOLS HVHZ (RAS) 115.1 (RAS) No. 115 e 6. contiguous thereto. In all cases, the deck flange shall be not less than 2 inches in width. Where required, a continuous clip (hook strip) shall be installed in compliance with RAS 111. 5.3 Eave and gable drip metal shall be joined by a lapped of a minimum of 4 in. and the entire interior of the joints shall be coated with approved flashing cement. Eave and gable drip metal shall be fastened with minimum 12 gauge annular ring shank nails at a maximum spacing of 4 in. o.c. The nails shall be manufactured from similar and compatible material to the ter- mination profile. All composite materials shall be fastened with nonferrous nails. All metal.profiles shall be installed in compliance with RAS 111. 5.4 Valley metal shall be a minimum 16 in. wide rolled or preformed material of thick- ness' in compliance with Section 1517.6 of the Florida Building Code, Building. Valley metal shall be set over the underlayment, or over an optional 18 in. sweat sheet. Fasten valley metal with minimum 12 gage by 1114 in. annular ring shank roofing nails of simi- lar materials 12 in. o.c.1 in. in from each ex- terior edge. The entire edge of the flange shall be sealed, covering all nail penetra- tions with flashing cement and membrane. All horizontal laps shall be a minimum of 6 in. and shall be fully embedded with ap- proved flashing cement. No nails shall be permitted in the center of the valley. Shingle Installation 6.1 At all intersections, eaves, rakes, valleys, and gable ends the shingles and starter strips shall be set in a minimum 8-in. wide strip of approved flashing cement. Maximum thickness of flashing cement shall be Vs in. as excessive use of the cement may cause blistering, or bleed through. Shingles shall not extend more than 1/4 in. beyond the eave drip. 6.2 The starter strip may be either a row of nonlaminated shingles trimmed to the shingle manufacturer's recommendations or a strip of mineral -surfaced roll roofing not less than 7 in.wide. 6.3 If self-sealing shingles are used for the starter strip, remove the tab portion of each shingle and position the remaining strip with the factory -applied adhesive face up along the eaves. Trim material from the end of the first shingle in the starter strip according to manufacturer's specifications to ensure that the cutouts of the first course of shingles are not placed over the starter strip joints. Fasten starter strips parallel to the eaves along a line above the eave line according to manufac- turer's specifications. Position fasteners to insure they will not be exposed under the cutouts in the first course. 6.4 For shingles without a self-sealing strip the tabs shall be removed and approved flashing cement shall be applied in spots, approximately the size of a quarter at the corner of each tab of the first course. Starter shingles shall be nailed along a line not greater than 4 in. above the eave line nailing not greater than 6 in. o.c. En- sure that the cutouts of the first course are not placed over the starter strip joints. 6.5 If roll roofing is used for the starter strip, nail along a line not greater than 4 inches above the eave line nailing not greater than 12 inches o.c. Approved flashing ce- ment shall be applied as noted above for nonsealing shingle starter. If more than one piece of roll roofing must be used, the end joint shall be butted. Joints shall be staggered with succeeding shingle joints, and the number of starter joints shall be kept to a minimum. 6.6 First course shall be laid straight, check- ing it regularly during application against a horizontal chalk line. A few vertical chalk lines aligned with the ends of shin- gles in the first course will ensure proper alignment of cutouts. A shingle hatchet is an acceptable alternative to the use of suc- ceeding chalk lines. The first course starts with a full shingle, while succeeding courses shall be installed in strict compli- ance .with the shingle manufacturers' Product Approval course layout detail. 6.7 Rake and valley courses shall be termi- nated with shingles not less than 12 in. in length. To obtain the correct exposure for square -tab strip shingles, align the butts (RAS) 115.2 FLORIDA BUILDING CODE — TEST PROTOCOLS HVHZ (RAS) No. 115 with the top of the cutouts in the course below. Install no -cutout shingles and those with variable butt lines according to the manufacturer's directions to obtain PROPERLY DRIVEN correct exposure. NOTE: Follow manufacturer's instruc- tions concerning shingle align- ment. See "Exposure, Course Layout, and Fastening Detail" in shingle manufacturer's Product Approval. 7. Fastening IMPROPERLY DRIVEN UNDERORNEN OvsWFU EN CROONED ASPHALT SHINGLES - UNDERLAYMENT DETAIL A 7.1 Use six approved nails per shingle. Place 8 .2 Open valley: Snap two chalk lines, one on each side of the valley centerline over the the fasteners in strict compliance with full length of the valley. flashing. Locate the shingle manufacturers Product Approval I I upper ends of the chalk lines G in. apart in course layout, fastening details. the center of valley at the ridge (i.e., three inches to either.side of the valley center- 7.2 Align the shingles properly to avoid ex- line). The lower ends should diverge from each other a minimum of /a in. per linear posing fasteners in the course below. foot of valley length, (i. e., for an eight foot Drive the fasteners straight and do not long valley the chalk lines shall be 7 inches break the shingle surface with the fastener apart at the eaves). head. Do not drive fasteners into knot holes or cracks in the roof deck. Repair faulty fastening immediately. If fastener As shingles are applied toward the valley, I I is improperly driven or exposed, remove trim the last shingle in each course to fit the fastener and repair the hole in the shin- on the chalk line. Never use a shingle gle with approved flashing cement or re- trimmed to less than 12 inches in length to place the entire shingle. finish a course running into a valley. If necessary, trim a tab off the adjacent shin- gle in the same course to allow a longer 7.3 Do not nail into or above factory -applied portion to be used, trim 1 inch on a 45-de- adhesives. Ensure no cutout or end joint is gree angle from the upper corner to direct less than 2 inches from a nail in an under- water into the valley and prevent it from. lying course. Start nailing from the end penetrating between the courses. Finally, nearest the shingle just laid and proceed to form a tight seal, cement the shingle to across. Do not attempt to realign a shingle the valley lining with a minimum by shifting the free end after two nails are eight -inch width of asphalt flashing ce- in place. Drive nails straight so that the ment. There should be no exposed nails edge of the nail head does not cut into the along the valley flashing. shingle. Nail heads should be driven flush with the shingle surface. Fasteners shall not be improperly driven (see Detail A). 8.3 Closed cut valley: With valley flashings already in place, apply the first course of shingles along the eaves of one of the in- tersecting roof planes and across the val- 8. Valleys ley. For proper flow of water over the trimmed shingle, always start applying the shingles on the roof plane that has the 8.1 Valleys may be applied in open, closed or lower slope or lesser height. Extend the end shingle at least twelve inches onto the woven fashion. Valley metal shall be in adjoining roof. Do not make a joint in; the compliance with Section 5.4. valley. If a shingle falls short, add in one or two tab sections so that joint occurs FLORIDA BUILDING CODE -TEST PROTOCOLS HVHZ (RAS) 115.3 (RAS) No. 115 outside the line of the valley. Apply suc- ceeding courses in the same manner, ex- tending them across the valley and onto the adjoining roof. Press shingle tightly into the valley. Use normal shingle fasten- ing methods except that no nails should be within six inches of the valley centerline and two nails shall be placed at the end of each shingle crossing the valley. Snap a chalk line two inches from the centerline of the valley on the under -shingled side. Then apply shingles on the under shingled side. Trim the shingles as they are being installed to the chalk lines to ensure a neat installation. Trim one inch on a 45-degree angle from the upper corner of each shin- gle upon installation. This will direct wa- ter into the valley. Finally embed each end shingle in a 3-inch (76 mm) wide strip of flashing cement. 8.4 Woven valley: The valley flashing should already be in place as described earlier. Shingles on the intersecting roof surfaces may be applied toward the valley from both roof areas simultaneously or each roof area may be worked separately up to a point about ihree feet from the center of -the valley and the gap closed later. Re- gardless of which procedure is followed; apply the first course along the eaves of one roof area up to and over the valley with the last shingle extending at least 12 inches onto the intersecting roof. Then apply the first course of the intersecting roof along the eaves and extend it across the valley over the top of the shingle al- ready crossing the valley and at least 12 inches onto the other surface. Apply suc- cessive courses alternately from the ad- joining areas, weaving the valley shingle over the other. Press each shingle tightly into the valley. Use normal shingle fasten- ing methods except that no nails should be within six inches of the valley centerline and two nails shall be placed at the end of each shingle crossing the valley. 9. Flashing 9.2 Option A: All wall abutments shall be flashed with a minimum of 4 in. by 5 in. "L" metal flashings of materials and thickness in accordance with Section 1517.6 of the Florida Building Code, Building. The metal "L" flashing shall be set in approved flashing cement and set flush to base of wall and over underlayment (see Detail B). Both hori- zontal and vertical metal flanges shall be fastened 6 inches o.c. with approved fas- teners. Fastening shall be in accordance with RAS 111. All laps shall be a mini- mum of 4 inches fully sealed in approved flashing cement. Flashing shall start at the lower portion of the roof to ensure wa- ter -shedding capabilities of all metal laps. The entire edge of the metal flashing shall be sealed covering all nail penetrations with approved flashing cement and mem- brane. The metal "L" flashing shall be counter flashed. All metal counter flash- ing shall be installed in accordance with RAS 111. 9.3 Option B: Roof planes that butt against vertical walls shall be step flashed with 10 in. long metal shingles which are 2 in. wider than the exposed face of the roofing shingles (see Detail C). Place the first flashing unit over the end of the starter strip and position it so that the tab of the end shingle in the first course covers it completely. Secure the horizontal arm to the roof with two approved roofing nails. Do not nail flashing to the wall; settling of the roof could damage the seal. Apply the 9.1 All shingles that butt against wall flash- ings shall be step bulled with approved flashing cement a minimum of eight DETAIL B inches, and all roof planes that butt against vertical walls shall be flashed in one of the following manners: (RAS) 115.4 FLORIDA BUILDING CODE — TEST PROTOCOLS HVHZ (RAS) No. 115 FLASHING PLACED UPSLOPE FROM EXPOSED EDGE OF SHINGLE EXTENDING 4 INCHES OVER UNDERLYING SHINGLE AND 4 INCHES UP VERTICAL WALL MINIMUM 2-INCH HEADLAP 1 VERTICAL WALL TURNED UP i VERTICAL WALLS MINIMUM 4 INCHES DETAIL C first course of shingles up to the wall. Po- sition the second step flashing strip over the end shingle in the first course 5 inches up from the butt.so that the tab of the end shingle in the second course covers it completely. Fasten the horizontal arm to the roof. The second course of shingles follows, the end is flashed as in the pre- ceding courses and so on to the top of the intersection. Bring siding or other wall treatment down over the vertical sections of the step flashing to serve as cap flash= ing. Wall treatment or cap flashing shall terminate a minimum of 1 in. above the roofline. All metal counter flashing shall be installed in accordance with RAS 111. 9.4 Head/apron flashing at all vertical end walls: Apply shingles up the roof until a course must be trimmed to fit at the base of the vertical wall. Adjust the exposure slightly in the previous two courses so that the last course is at least 8 inches wide. Apply a continuous piece of metal flash- ing over the last course of shingles by em- bedding it in approved flashing cement and nailing it to the roof. The metal flash- ing strip shall be bent to extend at least 5 inches up the vertical wall and at least 4 inches onto the last shingle course. Do not nail the strip to the wall. Apply an addi- tional row of shingles over the metal flashing strip, trimmed to the width of the strip. Bring siding down over the vertical flashing to serve as cap flashing. Wall treatment or cap flashing shall terminate a minimum of 1 in. above the roofline. Do not nail siding into the vertical flashing. If the vertical front wall meets a side wall, as in dormer construction cut flashing so that it extends at least 7 inches around the cor- ner. Continue up the side wall with step flashing as detailed above. 10. Soil Stacks and Vent Pipes 10.1 Apply shingles up to the vent pipe. Cut a hole in a shingle to go over the pipe and set the shingle in ASTM D 4586 flashing ce- ment. A preformed flashing flange that fits snugly over the pipe is then placed over the shingle and vent pipe and set in approved flashing cement. Place the flange over the pipe to lay flat on the shin- gle below. After the flashing is in place, resume.shingle application. Cut shingles in successive courses to fit around the FLORIDA BUILDING CODE — TEST PROTOCOLS HVHZ (RAS)115.5 (RAS) No. 115 11. t pipe and embed them in approved flash- overlap the flashing in an 8" bed of ap- ing cement where they overlap the flange. proved flashing cement. Place the rear Avoid excessive use of cement as it may base flashing over the cricket and the high cause blistering. Do not drive fasteners side of the chimney. Chimney crickets close to the pipe. The lower part of the shall be waterproofed in with flange shall overlap the lower shingles the shingle manufacturers published liter - and the side and upper shingles shall over- ature. All chimney flashings shall be lap the flange. countered flashed. Metal counter flashing shall be in accordance with RAS 111. 10.2 For ventilator and exhaust stacks, follow the same procedure, but bring the shingles 12. up to the pipe from both sides and bend the flange over the ridge to lie in both roof planes, overlapping the roof shingles at all points. Ridge shingles are then positioned to cover the flange. Embed the ridge shin- gles in approved flashing cement where they overlap the flange. Roof ventilators shall be flashed in accordance with venti- lators Product Approval. Chimneys 11.1 Chimneys shall be flashed with a two-piece base and cap flashing to allow for differential movement. Apply shin- gles up to the front edge of the chimney before any flashings are installed. Apply a coat of ASTM D 41 asphalt primer if the chimney is constructed of masonry or metal to seal the surface and to provide good adhesion to all points where flashing cement will later be applied. 11.2 Install flashing in accordance with Sec- . tion 9 above. Apply the base flashing to the low side of the chimney first. Bend the base flashing so that the lower section ex- tends at a minimum of 4 inches over the shingles and the upper section extends a minimum of 12 inches up the vertical face of the chimney. Work the flashing firmly and smoothly into the joint between the shingles and chimney: Set both the roof and chimney overlaps in approved flash- ing cement placed over the shingles and on the chimney face. The flashing shall be secured in accordance with RAS 111. Use metal step flashing for the sides of the chimney, positioning the units in the same manner as flashing on a vertical side wall, in accordance with Details A and B herein. Secure each flashing unit to the masonry with approved flashing cement and to the deck with approved nails. Em- bed the end shingles in each course that Hips and Ridges 12.1 Apply premanufactured hip and ridge shingle components or cut hip and ridge shingles from manufacturer's strip shin- gles. Lay hip and ridge away from prevail- ing wind. Insure all fasteners are covered. Exposure shall not exceed 5 inches. Taper the lap portion of each cap shingle slightly so that it is narrower than the exposed por- tion. (RAS) 115.6 FLORIDA BUILDING CODE — TEST PROTOCOLS HVHZ Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1148 http://stiucieco.gov/ce BUILDING PERMIT Issued: 09/27/2007 Conf #: 654 Permit #: SLC- 0709-0362 Job Location: 105 SE SELVA CT City: PORT ST LUCIE Permit Type: Roof Job Description: TEAR OFF CONCRETE TILE AND INSTALL OC DURATION PREMIUM SHINGLES Subdiv: River Park Unit 7 Lot: 6 Block: 66 Parcel: 3419-550-0057-000/9 Setbacks Left: Right: Number of Units: 1.00 Floors: 1 Minimum Floor Elevation: Job Value: $ 8,675.00 Front: Rear: Zoning: RS-4 Buildings: 1 Square Footage: 0.00 Flood Map: . Flood Zone: Elev: Page 1 Permit holder acknowledges through acceptance of this permit that separate permits must be obtained as required by the Florida Building Code including those for all electric, plumbing, mechanical, roofing, and structural work. Further, he/she acknowledges responsibility to comply with all requirements of the 2004 Florida Building Code. NOTICE: In addition to the requirements in this permit, there may be additional restrictions applicable to this property that may be found in the records of this County, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. s:553.79(10), F.S. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR BUILDING IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. s.713.135, F.S. Christopher Lestrange C? 21- dW% Building Official Date For Automated Inspections, Call (772) 462-1261 For Questions, Call (772) 462-2172 St. Lucie County Land Development Code Section 11.05.01 (A) (2) states; Building Permits shall expire and become null and void if work authorized by such Building Permit is not commenced, having called for and received a satisfactory inspection, within six (6) months from the date of issuance of the permit, or if the work is not completed within 18 months (permit by contractor) or 24 months (permit by owner) from the date of issuance of the Building Permit. Building Code Compliance Division Receipt 2300 Virginia Avenue Ft. Pierce, FL 34962 Phone: (772) 462-1553 Fax: (772) 462-2522 http://stiucleco.gov/ce Date: 27 September 2007 Job Address: 105 SE SELVA CT Received By: humphreya Paid With: CK Paid By: GARY MARZO Sign: Receipt #: 0000057732 'ermit Number: SLC- 0709-0362 Amount: $130.90 �redit Card Number: Check Number: 2629 OFFI. 'USE ONLY: r DATE FILED: o REVISION FEE: PERMIT NUMBER: C , C RECEIPT NO.:)5!q(c41/ - ST. LUCIE COUNTY DL4&TMENT OF COMMUNITY DEVELOPMENT BUILDING & ZONING 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-56�2� .• ._ ,, ,. .,.r.• . .462-1553 s fia .a. .'o APPLICATION FOR BUILDING PERM .si PROJECT INFOR3IATION 1. LOCATION, ADDRESS: 2. DETAILED DESCRIPnT�ONS OF PROJECT REVISIONS: UL n 0.U\ �_ k "AQ 3. CONTRACTOR INFOR.ti1ATION: ST..OF FL REG./CERT# BL:SINESS NA.NIE: Qualifiers Name: ADDRESS: ( CITY: 1 PHONE' (DAYTI`IE): ` 4. ARCHIT/EL GINEER: NAME: ADDRESS: _ CITY: PHONE (DAYTItiiE): _ COUNTY CERT.» n - STATE: ZIP: FAX# �3 Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 http://stfucieco.gov/ce Date: 04 October 2007 Job Address: 105 SE SELVA CT Received By: spelisv Paid With: CK Paid By: GARY MARZO Building Receipt Sign: Receipt#: 0000057941 ern it Number: SLC- 0709-0362 Amount: $50.00 �redit Card Number: Check Number: 2651 Florida Building Code Online r_1 http://www.floridabul�ng.org/pr/pr app_dtl.aspx?param=wGEVX... I ` F L AL BCIS Home i Log In Hot Topics; Submit Surcharged Stats & Facts Pubtica Sta CIS a,, p in Searchi HIM fM Product Approval F[LE 7 USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail * FL # FL3663-R4 i .... $ Application Type Revision THESE PLANS AND ALL PROPOSED WORK Code Version 2004 ARE SUBJECT TO ANY CORRECTIONS Application Status Approved REQUIRED BY FIELD INSRECTORI THAT Comments MAY BE NECESSARY IN ORDER I��iO Archived COMP WITH A_l�AftGA1041000906 Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo, OH 43659 (419) 248-7060 darrel.higgs@owenscorning.com Authorized Signature Darrel Higgs darrel.higgs@owenscorning.com <:> Technical Representative Address/Phone/Email Quality Assurance Representative COO> Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Certification Mark or Listing Certification Agency Underwriters Laboratories Inc. Referenced Standard and Year (of Standard Year Standard) ASTM D 3462 2001 ASTM D3161 (modified to 110 mph) 1999 UL 790 (Class A) 1997 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A ST lE COUNTY BUILDING DIVI Date Submitted 04/10/2007 REVE IO Date Validated 04/10/2007 EO Date Pending FBC Approval 04/11/2007 REVIEWED BY Date Approved 05/08/2007 DATE O•a•OPUNS D PERMIT MUST B EPT ON JOB OR NO INSPE TION WILL BE MADE 1 of 4 10/4/2007 9:50 AM Florida Building Code Online _ l http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVX... i Summary of Products f FL # rModel, Number or Name __.... Description 3663.1 ! Berkshire ;Laminate Shingle !! Limits of Use 'j Certification Agency Certificate jj Approved for use in HVHZ: No �� FL3663 R4 C CAC UL Certification Letter 4-3-07 j Approved for use outside HVHZ: Yes I! Owens Corning Shingles.pdf Impact Resistant: N/A FL3663 R4 C CAC UL Certification, Files R2453 j Design Pressure: N/A !! and R19380.pdf Other: 1.) This Approval not for use in the HVHZ. Installation Instructions 2.) All FBC sections that apply to counties except Broward and Miami -Dade must be followed. !i FL3663 R4 II Install Documents Berkshire.pdf 1� FL3663 R4 II Install Documents Starter Shingle Roll.pdfli Verified By: Underwriters Laboratories Inc. j 3663.2 ! Classic or Classic AR , 3 Tab Shingle ! I Limits of Use ! Certification Agency Certificate Approved for use in HVHZ: No j FL3663 R4 C CAC UL Certification Letter 4-3-07 Approved for use outside HVHZ: Yes ! Owens Corning Shingles.pdf Impact Resistant: N/A i FL3663 R4 C CAC UL Certification, Files R2453 I Design Pressure: N/A and R19380.pdf Other: 1.) This Approval not for use in the HVHZ. I Installation Instructions j 2.) All FBC sections that apply to counties except FL3663 R4 II Install Documents Starter Shingle Broward and Miami -Dade must be followed. Roll.pdf FL3663 R4 II Install Documents Three Tab.pdf i Verified By: Underwriters Laboratories Inc. 63.3 Oakridge (Oakr;dge PRQ 30- Laminate Shingle with or without SureNail ARC), Oakr dge PRO 3O with#technology SUreNall Technology Limits of Use i Certification Agency Certificate i! Approved for use in HVHZ: No ;! FL3663 R4 C CAC UL Certification Files R2453 !! Approved for use outside HVHZ: Yes I and R19380.pdf Impact Resistant: N/A jj FL3663 R4 C CAC UL Certification Letter 4-3-07 j Design Pressure: N/A !! Owens Corning Shingles.pdf Other: 1.) This Approval not for use in the HVHZ. !i Installation Instructions 2.) All FBC sections that apply to counties except FL3663 R4 II Install Documents Oakridge Pro with Broward and Miami -Dade must be followed. SureNail.pdf i ! FL3663 R4 II Install Documents Oakridge.pdf FL3663 R4 II Install Documents Starter Shingle Roll.pdf i Verified By: Underwriters Laboratories Inc. .: —'-'- ...............----'— '......_-...._.—...._..---- ..... _........... 3663.4 Oakridge PRO 40 AR, Oakridge :� -------'--- -----.._.----'--......, Laminate Shingle with or without SureNail PRO 40 AR with SureNail ! Technology i Technology 4 j — ! Limits of Use I Certification Agency Certificate i Approved for use in HVHZ: No FL3663 R4 C CAC UL Certification Files R2453 j and R19380.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: FL3663 R4 C CAC UL Certification Letter 4-3-07 Owens Corning Shingles.pdf N/A Other: 1.) This Approval not for use in the HVHZ. i Installation Instructions 2.) All FBC sections that apply to counties except FL3663 R4 II Install Documents Oakridge Pro with Broward and Miami -Dade must be followed. SureNail.pdf FL3663 R4 II Install Documents Oakridge Pro.pdf j FL3663 R4 II Install Documents Starter Shingle Roll.pdf Verified By: Underwriters Laboratories Inc. I j 3663.5 rOakridge PRO 50 AR, Oakridge 1' Laminate Shingle with or without SureNail i PRO 50 AR with SureNail Ij Technology "Technology ! 2 of 4 10/4/2007 9:50 AM Florida Building Code Online http://www.floridabuilding.org/pr/pr�_app_dtl.aspx?param=wGEVX... H Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL3663 R4 C CAC UL Certification Files R2453 Approved for use outside HVHZ: Yes 11 and R19380.pdf Impact Resistant: N/A il FL3663 R4 Q CAC UL Certification Letter 4-3-07 Design Pressure. N/A iiOwens Corning Shingles.pdf Other: 1.) This Approval not for use in the HVHZ. 11 Installation Instructions H 2.) All FBC sections that apply to counties except it FL3663 R4 II Install Documents Oakridge Pro with Broward and Miami -Dade must be followed. SureNail.pd FL3663 R4 11 Install Documents Oakridge Pro.pd FL3663 R4 II Install Documents Starter Shingle Roll.pd .............. ......... .. ...... ... ...... . ...... . ............ ..... ............... .............. ....... ..... .......... ............. .............. ..... . ........ ­­ .... . . . ................. ............ . . . . . . . . . . . . . . . . .. . . . Verified By: Underwriters Laboratories Inc. - .................. .................... ......... ................. ....................... ... - ............ .......... . ........................ . .... . .. . ....... . ......... . . . .... ............. . . ............... . . . . ... . ...... 3663.6 I Prominence AR 13-Tab Shingle . .. . ...... ... . ............... ......... ... . .. . ..... . Limits of Use . . . ..... ------ ­­­­..__. . .. . .... ........ . ....... ........... . . ...... . ..... . . . .... . . ............. ............. . .......... Certification Agency Certificate Approved for use in HVHZ: No FL3663 R4 Q CAC UL Certification Letter 4-3-07 Approved for use outside HVHZ: Yes Owens Corning Shingles.pdf Impact Resistant: N/A .1 FL3663 R4 Q CAC UL Certification, Files R2453 Design Pressure: N/A j and R19380.pdf Other: 1.) This Approval not for use in the HVHZ. lInstallation Instructions 1 2.) All FBC sections that apply to counties except FL3663 R4 II Install Documents Starter Shingle I Broward and Miami -Dade must be followed. Roll.pd FL3663 R4 II Install Documents Three Tab.pdf ................ . . . ...... . .. . . ...... . .......... .................... . 1 Verified By: Underwriters Laboratories Inc. .. . ....... . ...... ... . . ............ .... . ....... .. . ......... . .. . . . . ............ . . ...... ... .. ... .. ................... . ...... .................. .... . .. ............ ........... ... .. 3663.7 Starter Shingle Roll Starter Roll ..................... . . . . ............ . .. . . I Limits of Use . .. ........ ... .... . .. .......... ........... . ........ Certification Agency Certificate Approved for use in HVHZ: No FL3663 R4 C CAC UL Certification, Files R2453 Approved for use outside HVHZ: Yes and R19380.pdf ii Impact Resistant: N/A ii Installation Instructions Design Pressure: N/A FL3663 R4 II Install Documents Starter Shingle Other: 1.) This Approval not for use in the HVHZ. Roll.pd 2.) All FBC sections that apply to counties except Verified By: Underwriters Laboratories Inc. H Broward and Miami -Dade must be followed. ... .. ... ...... .... .. . . .. .. . ............................... . . . .. ...... . . ................ . ...... ............. . . . - ------------ . ... . ..... ......... ...... ..... .......... . . ........... .. 13663.8 i Supreme AR . ........ .. ....... .......... ..... . ............ 3-Tab Shingle Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL3663 R4 C CAC UL Certification Letter 4-3-07 Approved for use outside HVHZ: Yes Owens Corning Shingles.pdf Impact Resistant: N/A FL3663 R4 C CAC UL Certification, Files R2453 Design Pressure: N/A I and R19380.pdf Other: 1.) This Approval not for use in the HVHZ. :1 Installation Instructions 2.) All FBC sections that apply to counties except FL3663 R4 II Install Documents Starter Shingle Broward and Miami -Dade must be followed. Roll.pd FL3663 R4 II Install Documents Three Tab.pdf Verified By: Underwriters Laboratories Inc. ..... ............ . ............ ..... ............. ............................ .............. .............. i! 3663.9 WeatherGuard HP . ...... ... .................. . ........ - .............. ............. ------ . ............. - ............. . ...... ................... . i Laminate Shingle . .... ..... ....... ............. Limits of Use . Certification Agency Certificate Approved for use in HVHZ: No j FL3663 R4 C CAC UL Certification Letter 4-3-07 Approved for use outside HVHZ: Yes Owens Corning Shingles.pdf Impact Resistant: N/A i FL3663 R4 C CAC UL Certification, Files R2453 Design Pressure: N/A and R19380.pdf Other: 1.) This Approval not for use in the HVHZ. I Installation Instructions il 2.) All FBC sections that apply to counties except FL3663 R4 II Install Documents Starter Shingle Broward and Miami -Dade must be followed. 1 Roll.pd FL3663 R4 11 Install Documents WeatherGuard HP. pdf . .............. . . ........................ . .......... Verified By: Underwriters Laboratories Inc. . I! ......... . . ........ . ....... - ..................................................... . ........ . .. . ......... ............. . ... . .... . ............. Back FN..tl DCA Administration 3 of 4 10/4/2007 9:50 AM Florida Building Code Online http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVX... Department of Community Affairs Florida Building Code Online Codes and Standards 2555 Shumard Oak Boulevard Tallahassee, Florida 32399-2100 (850) 487-1824, Suncom 277-1824, Fax (850) 414-8436 © 2000-2005 The State of Florida. All rights reserved. Copyright and Disclaimer Product Approval Accepts: BE v�r�sigd sp� b�tvnd ,pp� vMF 4 of 4 10/4/2007 9:50 AM Underwriters Labera#aries Inca April 3, 2007 Mr. Ted Berman P.E. Senior Project Manager A&A Arnold & Associates, Inc. 1711 W 38th Place, Unit 1207 Hialeah, FL 33012-7077 Subject: Owens Corning Dear Mr. Mr. Berman: Nlorthbrok DiVlsion 333 P6ri gdn Rood NorthkrgdCJi 60082-2096.USA mmuLcom tej; i' 84T272 8800 fox- J 84T 272.8129 Cusiomerk kfcei 1877854 3577 This is to confirm that, Oakridge® PRO 30TM with Surenail, Oakridge® PRO 30TM AR with Surenail, Oakridge® PRO 40TM with Surenail, Oakridge® PRO 40TM AR with Surenail , Oakridge® PRO 50TM with Surenail, and Oakridge® PRO 50TM AR with Surenail, Duration, Duration Premium, Classic® or Classic® AR, Supreme® or Supreme® AR, Prominence® or Prominence® AR, Oakridge® (Oakridge® PRO 30TM) or OakridgeC'(OakridgW PR030 'M AR)- Oakridge® PRO 40TM or Oakridge® PRO 40TM AR, Oakridge® PRO 50TM or Oakridge® PRO 50TM AR, Berkshire and WeatherGuard HP are Listed in accordance with ANSI/UL790, Class A (ASTM E 108, Class A), ASTM D3462, UL 997/ASTM D3161 (modified to I 1 Omph) and Dade County Protocol 107-95. The Berkshire secured with 5 nails, WeatherGuard HP secured with 6 nails and all other shingles secured with 4 nails. All the products have been tested and meet the criteria for these standards and are covered by UL's Follow -Up Service Program for File R2453. If you should have any questions, please feel free to contact the writer. Very truly yours, Martin K. Rowan (Ext. 42349) Senior Project Engineer Fire Protection Division An =ntl.aperrda.i�t .org-Srti o��toh wprk,in, . for a waird 'Vi,nzlf 'IntelotF3y..;tr.rec�ISi�60 grid knobledge•_ TGDY.R19380 -Prepared Ro-, r ,yg Accessories Page 1 of 1 Laboratories Inc.,v TGDY.R19380 Prepared Roofing Accessories Page Bottom Print -friendly version Questions? Prepared Roofing Accessories See _General Information for Prepared Roofing Accessories OWENS CORNING R19380 WORLD HEADQUARTERS 1 OWENS CORNING WAY TOLEDO, OH 43659 USA Asphalt underlayment accessories, "WeatherLock®G", "WeatherLock®M", "WeatherLock®P", "Starter Shingle Roll for Eave & Rake Edge" self -adhering modified bitumen membrane for use in the installation of Class A asphalt glass fiber mat shingles and Class C asphalt organic felt shingles. "WeatherLock®Metal" self -adhering modified bitumen membrane for use in the installation of Class C metal shingles. Page Top UL Listed and Classified Products Notice of Disclaimer UL Recognized Components Last Updated on 2004-10-14 Questions? Products Certified for Canada This page and all contents are Copyright © 2005 by Underwriters Laboratories Inc.® The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow -Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non - misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright © 2005 Underwriters Laboratories Inc.®" http://database.ul.comlcgi-binIXYVItemplatelLISEXT/1 FRAMElshowpage.html?name=TG... 7/7/2005 TFWZ.R2453 - Prepared Rou '`, vering Materials Page 1 of 2 QUnderwriters Laboratories Inc. TFWZ.R2453 Prepared Roof Covering Materials Page Bottom Print -friendly version Questions? Or--rr�us�� Pge i Prepared Roof Covering Materials See General Information for Prepared Roof Co_v_ering. Materials OWENS CORNING R2453 WORLD HEADQUARTERS 1 OWENS CORNING WAY TOLEDO, OH 43659 USA Asphalt glass fiber mat sheet roofing, for installation as Class C prepared roof coverings. Asphalt glass fiber mat and hip and ridge shingles , for installation as Class A prepared roof coverings. Suitable for installation on minimum 3/8 in. thick plywood decks with underlayment such as asphalt saturated felt or shingle underlayment classified by UL as a prepared roofing accessory (underlayment not required for hip and ridge shingles) and on minimum 15/32 in. thick plywood decks without underlayment. Asphalt glass fiber mat shingles, for installation as Class C prepared roof coverings on minimum 3/8 in. thick plywood decks without underlayment. Asphalt glass fiber mat and hip and ridge shingles for installation as wind resistant roof coverings. These shingles may also bear the statement "Also evaluated at wind velocities up to 110 mph". Asphalt glass -mat shingles, Classified in accordance with ASTM D3462, including tear resistance. Asphalt glass -mat shingles, Classified in accordance with CSA-A 123.5-M90. French method shingle, Class A, for use in reroofing. Modified asphalt.self adhering glass fiber mat sheet roofing, for installation as Class C prepared roof coverings. Suitable for installation on minimum 3/8 in. thick plywood decks. Page Top _UL Listed_ and Classified_ Products Notice of Disclaimer UL Recognized Components Last Updated on 2004-01-14 Questions? Products Certified for Canada http://database.ul.com/cgi-binIXYV/templatelLISEXT/1 FRAME/showpage.html?name=TF... 7/7/2005 Installation Instructions Oakridge These laminated shingles are designed for new or reroofing work over any properly built and supported wood roof deck having ade- quate nail holding capacity and a smooth surface. UL Class A Fire Resistance & Wind Resistance Ratings When applied in accordance with these instructions, these shingles carry the Underwriters Laboratories Class A fire resistance rating, the top rating for residential shingles. They will resist exposure to fire in accordance with UL Standard 790. When applied properly, these shingles also meet UL wind resistance Standard 997. All lami- nated shingles have a factory -applied strip of special thermoplastic adhesive on each shingle. After direct exposure to the sun's heat, each course bonds securely to the course below (a matter of days in spring through fall seasons, in winter it varies depending on geographical location, roof slope and orientation of the house on the site, in relation to the sun) . Other Roofing Materials Metal Drip Edges - are recommended along rake and eaves edges of all decks. Underlayment - is recommended for roofing over any bare deck, and is required for a UL Class A fire rating. Use only "breather type" material such as Asphalt Saturated Felt or Shingle Underlay- ment classified by UL as a Prepared Roofing Accessory to assure Class A fire performance and watertight performance from wind -driven rain. Nails - must be galvanized, 11- or 12-gauge, with heads at least 3/8" in diameter. Staples must be 16-gauge minimum, 15/16" minimum crown width and sufficient length to penetrate 3/4" into wood decking or through APA rated roof sheathing. Staples are to be corrosion protected. All Fasteners - must penetrate at least 3/4" into wood deck or completely through plywood sheathing. Note: Owens Corning recommends the use of nails as the preferred method of attaching shingles to wood decking or other nailable surface. Plastic Cement - where required must meet ASTM D 4586 Type II (Asbestos Free). PROS` Series Laminate Shingles 11 Deck Preparation For Standard Slope Decks (4" in 12" or more) Application of underlayment, metal drip edges and eaves flashing: (A) Apply one layer of underlayment over metal drip edge at eaves. Use only enough fasteners to hold in place. (B) Overlap successive courses 2". Overlap course ends 4". Side laps are to be staggered 6' apart. (C) Apply metal drip edge over underlayment at rake. Note: Where ice -damming may cause leaks, apply Owens Corning WeatherLock" underlayment or equivalent eaves flashing at least 24" beyond the inside wall line. When using a coated smooth roll or mineral surfaced roll roofing, apply over the underlayment. When using a spe- cialty eaves flashing product, follow the manufacturer's instructions. 1 b Deck Preparation For Low Slope Decks (2" in 12" to less than 4" in 12'1 Application of underlayment, metal drip edges and eaves flashing: (A) Apply 19" starter strip of underlayment over metal drip edge at eaves. Use only enough fasteners to hold in place. (B) Use 36" strip of underlayment for remaining courses, overlap- ping each course 19". Side laps are to be staggered 6' apart. (C) Apply metal drip edge over underlayment at rake. Note: Where eaves flashing is required apply Owens Corning Weather - Lock underlayment or equivalent specialty eaves flashing product or apply a continuous layer of asphalt plastic cement between the plies of underlayment at least 24" beyond the inside wall line. l Laminate Shingles Oakridge® PRO' Series 2 Shingle Application Apply shingles over properly prepared roof deck, starting at bottom of roof and working across and up. This will blend shingles from one bundle into the next and minimizes any normal shade variation. Laminated shingles are applied with a 6-1/2" offset. While a 6-1/2" offset is recommended, any repeatable offset pattern from 4" to 8" is acceptable. Caution must be exer- cised to assure that end joints are no closer than 2" from a fastener in the shingle below and that side laps are no less than 4" in succeeding courses. Refer to course applications steps for specific instructions. Starter Course (see illustration on the right) (A) Trim tabs off all starter course shingles. (B) Trim 6-1/2" off rake end of first shingle. Extend 3/8" beyond rake and eaves, and fasten. (C) Complete rest of starter course. Note: Start at rake edge. Use five fasteners for each shingle, placed 2" to 3" up from the eaves. First Course (A) Apply first course starting with a full shingle, even with the starter course. Fasten securely according to instructions. Note: Complete course with full shingles. The fastening line should not be used for course alignment of shingles. Second Course (B) Begin second course by positioning first shingle 6-1/2" from the end of the underlaying shingle, and flush with the top of the overlay tab (dragon tooth) . (C) Leave 5-5/8" exposure, fasten securely, and trim excess overhang at rake. Note: Complete course with full shingles. Third Course (D) Begin by positioning the first shingle 6-1/2" from the end of the underly- ing shingle, flush with the top of the dragon tooth pattern. Complete by repeating step (C). Note: Complete course with full shingles. Fourth Course (E) Begin the fourth course by positioning the first shingle an additional 6-1/2" from the end of the underlying shingle, flush with the top of the dragon tooth pattern. Complete by repeating step (C). Note: Complete course with full shingles: Fifth Course (F) Begin fifth course by positioning full shingle flush with rake edge and leave 5-5/8" exposure. Complete by repeating step (C). Note: Complete course with full shingles. For succeeding courses repeat steps for second, third, fourth and fifth courses. 3 Valley Construction A closed cut valley is recommended and is applied as follows: (A) Lay a 36" wide valley liner of smooth surface roll roofing or Owens Corning WeatherLock underlayment or equivalent product. Fasten on outer edges only. (B) Lay all shingles on one side of valley and across centerline of valley a minimum of 12". Fasten a minimum of 6" away from centerline on each side of valley. (C) Strike a chalk line 2" from the centerline of the unshingled side. Apply shingles on the unshingled side up to the chalk line and trim, taking care not to cut the underlying shingles. Clip upper corners of these shingles, cement and fasten. (D) A metal valley is an acceptable alternative. A woven valley is also acceptable for Oakridge® PRO 3r . 4 Fastening Instructions Place fasteners 6-1/8" from bottom edge of each shingle and 1" from each end. (A) Use four fasteners in normal wind areas. (B) Use six fasteners per shingle for mansard construction. Use of six fasteners is recommended in high wind areas. Note: Fasten on the 646" nail line to penetrate both segments of the shingle. 5 Hip & Ridge Application High Ridge Hip & Ridge and High Style® Hip & Ridge available by region. If cutting three tabs for Hip & Ridge shingles, adhere to the following instructions. Cut full three -tab shingles into three 12" x 12" (13-1/4" x 13-1/8" metric) Hip & Ridge shingles. Start hips at the eave and work up to ridge. Apply ridge only after hips have been applied, beginning on end of ridge opposite prevailing wind direction. Leave 5" (5-5/8" metric) exposure per shingle for Hip & Ridge application. Bend over the ridge; fasten on each side 5-5/8" (6-1/4" metric) from exposed end, 1" up from the edge. Cover exposed nails with asphalt plastic cement. For more information on Hip & Ridge shingle application refer to Owens Corning's "How to Apply Hips & Ridges" (Pub. No. 5-RR-18491). Note: For best appearance, when using three -tab shingles for Hip & Ridge, apply double thickness (two 12" x 12" shingles or 13-1/4" x 13-1/8" if using metric -sized products) . Do not cut Hip & Ridge shingles from full size laminated shingles. Standard Area High Wind, Mansard or Steep Slope Pr 3�IAl�-tz•t. ��a. 8(61�8. WWI 56/a" Exposure Dragon Tooth 'hingla Side mew Fastener Through Nail Line Prevailing Wind Direction A -- Prevailing Wind Direction r Hip and ridge cut from 3-tab shingles. Hip and ridge cut from metric three -tab shingles Distance Laminate Shingles Oakridge® PRO` Series 6 Precautionary Notes The manufacturer will not be responsible for problems resulting from any deviation from the recommended application instructions and the following precautions: (A) Roof Deck: Recommended roof decks are 6" maximum width, 25/32" minimum thickness wood sheathing, or 3/8" minimum thickness plywood sheathing. Use plywood decking recommended by the American Plywood Association, Underwriters Laboratories, Inc., or local building codes. These Owens Corning shingles have been tested and rated as Class A by Underwriters Laboratories when these shingles are applied over recommended decks. If other decks are used, the resulting construction may not qualify as Class A. Regardless of deck type used, the roofing installer must: 1. Install the deck material in strict compliance with the deck manufacturer's instructions. 2. Prevent the deck from getting wet before, during and after installation. 3. Insure the attic ventilation meets or exceeds FHA Minimum Property Standards. Note: All roof structures, especially Mansard style construction, must have complete through ventilation from bottom to top to prevent entrapment of moisture -laden air (winter) and hot air (summer). Both conditions may cause premature shingle failure. It is extremely impor- tant to maintain adequate ventilation when reinsulating or reroofing. Structures with bath and kitchen vents, which are vented directly into the attic space, may require additional ventilation to remove excess moisture vapor. (B) Handling: Use extra care in handling shingles when the temperature is below 40° F. Do not drop bundles. Shingles can be broken easily in cold weather or their edges damaged in hot weather. Do not attempt to separate shingles by "breaking" them over another object such as a ridge. (C) Fastening: Owens Corning recommends nails as the preferred method of attaching shingles to wood decking or other nailable surface. Drive all fasteners until they are flush with the surface of the shingle. Special care must be taken in the use of pneumatic staples or nail guns. Staples are to be driven with a pneumatic stapler with crown parallel to length of shingle so that the entire crown bears tightly against the shingle but does not cut the shingle surface. Nails are to be driven straight so OWENS CORNING WORLD HEADQUARTERS ONE OWENS CORNING PARKWAY TOLEDO, OHIO, USA 43659 the entire head is flush against the shingle but does not cut the shingle surface. An improperly adjusted pneumatic gun can result in raised fasteners causing sealing failure, raised tabs, leaks or blow -off. Guidelines on fastener size, number and location must be followed. Failure to follow these instructions seriously reduces wind resistance. Owens Corning will not be responsible for any wind damage that occurs with shingles which have not been applied in accordance with these instructions. (D) Mansard or Steep Slopes: For slopes exceeding 60 degrees or 21 inches per foot, use six fasteners and four spots of asphalt plastic cement per shingle. All six fasteners must be spaced equally and placed in the fastening line. Place four spots of asphalt plastic cement, 1" in diameter, under each shingle immediately upon installation. (E) Storage: Store in a covered ventilated area at a maximum temperature of 110' F. Stack in a flat fashion (maximum of 16 bundles high) . Protect shingles from weather when stored at the job site. Do not store near steam pipes, radiators, etc. (F) Hip & Ridge Shingles: These shingles should be cut from the back (smooth) side. In cool weather, shingles can be formed more easily to fit the ridge if they are stored in a warm indoor area, then taken out immediately before application. (G) All exposed material must be rated Class A by Underwriters Laboratories, to maintain a Class A system. 7 Reroofing If old asphalt shingles are to remain in place, nail down or cut away all loose, curled or lifted shingles. Sweep the surface clean of all loose debris just prior to applying the new roofing. Ensure proper size and length of fasteners. If roofing over old wood shingles, cut back the old shingles at eaves and rakes and apply wood edging strips. Some local building codes may require the use of a No. 30 asphalt saturated felt over the old wood shingles prior to reroofing. Consult local building code authorities. The surface must be smooth before shingles are installed. Make deck smooth by nailing down all loose and curled shingles, protruding nails, etc. Install beveled wood feathering strips, if necessary.. Pub No.15-RR-15959-E Printed in U.S.A., December 2001 Copyright 0 2001 Owens Corning HIGH RIDGh -1�IP & RIDGE ziplication instructions for ,nSealant �%High Ridge Hip & Ridge INNOVATIONS FOR LIVING" with z with Sealant Shingles Owens Corning High Ridge Hip & Ridge with Sealant Shingles are designed to complement laminated and laminated - looking shingles.They are a high profile shingle which adds dimension to your home's hips and ridges. Before You Begin Complete shingle application on roof deck before applying High Ridge Hip and Ridge shingles. Hip shingles must be applied before applying ridge shingles. Note If a new roof is being applied over an existing roof, remove the old hip and ridge shingles to obtain a level application. Fastening Use nails only when installing this product. Nails must be corrosion resistant, I I- or 12-gauge, with heads at least V in Hip & Ridge Shingle Application diameter. Apply one nail on each side 10" from the exposed end and I " in from the side edge. (See Fig. B) For High Wind, apply two nails on each side 9" from the exposed end, and I" and 2" in from the side edge. (See Fig. 2) All fasteners must penetrate at least X" into wood deck or completely through plywood sheathing. Cover exposed fasteners with asphalt plastic cement. Plastic cement must meet ASTM D-4586 Type I or I I (Asbestos Free). Installing Begin hip application at the eave working toward the ridge. Begin ridge application opposite the prevailing wind direction. Arrange shingles along the center line so that both halves of the laminated piece 4 Fig.A 4 Prevailing Wind Direction Neil A \ 4 I I \\\y I I I I A I I I I Q I I I I I 1 I I I I I I I I A � � + V W Exposure Fig. 1 �— Preva0ingWlnd ei ecgon A Nalls��► A Q I 1 A 1 I 1 1 A 1 I Q 1 I I 1 1 I I I I 1 1 1 1 I I A � `1 1 1 + EIp09U10 fall on opposite sides of the hip or ridge. (See Fig. B) For High Wind (See Fig 2). Hip & Ridge Application Apply remaining hip and ridge shingles in the same manner with 8" exposure. (See Fig.A.) For High Wind (See Fig. 1). When finishing the ridge, leave no laminated portion of the last hip and ridge exposed. One option is to use the 8" exposed portion of a hip and ridge shingle, cutting a piece the appropriate length to extend over the laminated portion of the shingle to the end of the ridge. Fasten final piece with two nails, each I " in from the side edge and I" in from the end of the ridge. For High Wind use four nails, each I" and 2" in from each side edge and 111 in from the end of the ridge. Cover exposed fasteners with asphalt plastic cement. Hip & Ridge Shingle Fastening Fig.B TopVlew Side View Fig. 2 Topvl- SidoVim Nails Nails sE -F I Top lamin'lod 12 1 pi— 1 t 1 I I I I =1 I g� �I C, VI 1 I I I I 12•~I OWENS CORNING SHALL NOT BE RESPONSIBLE FOR ANY DAMAGE, LOSS, COST, EXPENSE OR LIABILITY RELATING TO FAILURE TO FOLLOW THESE INSTRUCTIONS. FAILURE TO FOLLOW THESE INSTALLATION INSTRUCTIONS MAY AFFECT OWENS CORNING OBLIGATIONS UNDER THIS PRODUCT'S LIMITED WARRANTY. Installation Instructions Owens Corning High Style Hip & Ridge Shingles are designed to complement laminated and laminated -looking shingles. They are a high profile shingle which add dimension to your home's hips and ridges. Before You Begin Complete shingle application on roof deck before applying hip and ridge shingles. Hip shingles must be applied before applying ridge shingles. All hip and ridge shingles are applied with an 8" exposure. Note: If a new roof is being applied over an existing roof, remove the old hip and ridge shingles to obtain a level application. 1 t Exposure Nail 9% Back Fastening Use nails only when installing this product. Nails must be galvanized, 11- or 12-gauge, with heads at least 7/16" in diameter. Nails should be places 9-1/2" back from the exposed end and 1" in from the side edge. All nails must be covered by succeeding shingles at least E'' All fasteners must penetrate at least 3/4" into wood deck or completely through plywood sheathing. In high wind areas apply a spot OWENS CORNING WORLD HEADQUARTERS ONE OWENS CORNING PARKWAY TOLEDO, OHIO, USA 43659 of elastometric roof cement, the size of a quarter, on each side of the hip or ridge, on the dimensional fold prior to installing the succeeding shingle. Cover exposed fasteners with elastometric roof cement. Installing ,4-- Prevailing Wind Direction I- cut 8•• —►I 1. Begin hip application at the eave working toward the ridge. 1a. Begin ridge application opposite the prevailing wind direction. 2. Cut first High Style Hip & Ridge shingle 8" up from the exposed end (along the dimensional fold). Use the remaining 8-1/2" portion of the shingle, with the dimensional fold, as the "starter" hip or ridge shingle. 3. Install this "starter" shingle with the dimensional fold positioned at the leading edge of the hip or ridge. Fasten through the dimensional fold with one nail on each side, placed 1-1/2" in and 1" up from the cut edge. Nail 9',i" Back 8" Exposure ROOFING SYSTEMS BUSINESS System Thinking' is a trademark of Owens Corning. The Pink Panther is a TM and © of United Artists Corp. Licensed by MGM Consumer Products. Printed U.S.A., March 2000 Copyright © 2000 Owens Corning. Starter Shingle High Style° Hip & Ridge Shingles 4. Completely cover "starter" shingle with the 8" exposed portion of the next hip and ridge shingle. 5. Fasten each shingle through the dimensional fold with one nail on each side, placed 9-1/2" back from the exposed end and 1" in from the side edge. All nails must be covered by succeeding shingles at least E'' Apply remaining hip and ridge shingles in the same manner with 8" exposure. 6. Cut final ridge shingle from the 8" exposed portion of a hip and ridge shingle. Cut piece an appropriate length to extend from the edge of the dimensional fold to the end of the ridge. 7. Fasten final piece with two nails, each 1-1/2" from the edge and 1" in from the end of the ridge. Cover exposed fasteners with elastomatic roof cement. Cut To Fit