HomeMy WebLinkAboutSUBMITTED PAPERS.i --
1.
2.
3.
4.
5.
• r L d n
Permit Numbers
�-� St. Lucie County.
Building .< Ilding &Zoning Department ������
" 2300 Virginia Avenue
Fort Pierce, FL 34982 �$' LuCBy
.772-462-1553 county
APPLI.CATION FOR STORM SHUTTER PERMIT
SEE REVERSE SIDE FOR INSTRUCTIONS DATE: • v
LOCATION%SITE ADDRESS: pk F;� . p'� p r e , V i-A q (yy
PARCEL ID NUMBER: 46M- blol — ` bb -
SECT
TWP
RNG
MAP
ZNG
LU
INIT
1343
a3sH
TYPE OF STRUCTURE: SFR
OWNER INFORMATION 6.
Name: —`t k Q Q L, 20.n2 I
Address: 3no N )gin • 4- I l c5l
City:' State: fL
Zip: Phone: -77a - Y(P,5---2059
Type of Surface attachment: Wood Frame
OTHER
CONTRACTOR INFORMATION
l 4
FL Reg/Cert it:
County Cert #: Q ,S ` Q
Business Name: FXzer-.¢ ,5t1( Vi
Concrete Y ; _ Masonry-,.- Other
Product
Minimum Design Pressure
Product Compliance
Report #
Method of Attachment.
As per 1707.4.4.1 FBC
Type
120 mph
130 mph
140 mph
140 Exp. C
SBCCI
Dade
Other'"
Anchor Type
Anchor Spacing
Impact Glazing
Removable Panels
Accordion
F7 P_tL
S2 2 rl�
Roll U
Colonials
Other
ALL rtcL)ll u C l S SHALL BE LAt3LED SBCCI OR DADE COUNTY FOR DETERMINING IMPACT RESISTANCE FROM
WIND BORNE DEBRIS. **SEE FINAL INSPECTION PROCEDURE FOR EXISTING RESIDENTIAL STRUCTURES ON BACK.
7. VALUE OF CONSTRUCTION: $ o) v FEES DUE: �J ` 0
RECEIPT:
OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is cone that ork will one in
compliance with all applicable laws regulating construction and z6niry .
PRINT QUALIFIERS/OWNERS NAW
STATE OF FLORIDA, COUNTY OF
ACKNOWLEDGED BEFORE ME THIS , _ DAY OF q 20 0-7 BY,
OR WHO HAS PRODUCED AS IDENTIFICATION.
SIGNA1i1JRE OF NOTARY
TITLE: NOTARY PUBLIC
SIGNATURE
WHO 1 T' ONA
TYPE bR PR N f NAME, OF NOTARY
COMMISSION NUMBER M Q ! j -lC)e C\
Y KNOWN TO
NOTICE TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU
INTEND TO OBTAIN FINANCING. CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
Ashley Danielle Rwrela
a� My Commission D6297M
EOMS March 07, 2006
- Property Appraiser - St.Lucie Cou^'� , FL
Alk
Page 1 of 1
Lila M O'Leary Record: 1 of 1
Property Identification
Site Address: 3880 N A1A
Sec/Town/Range: 23 :34S :40E
Map ID: 14/23S
Zoning:
Ownership and Mailing
Owner: Lila M O'Leary
Address: 3880 N A1A Unit 1101
Fort Pierce FL 34949
PROPERTY RECORD CARD
e<Prev Next» Spec.Assmnt Taxes Exemptions Permits Home Print
ParcellD: 1423-805-0108-000-0 \��tiOClf e�Gy
Account #: 141842 y'
Land Use: Condo to
City/Cnty: ST. LUCIE COUNTY
Legal Description
HIBISCUS -BY -THE SEA CONDOMINIUM BLDG 2 UNIT 1101(1243-
2026)
Sales Information
Assessment TRIM
Total Land and Building
Date Price Code
Deed Book/Page 2007 TRIM:
568300
Land Value: 0 Acres: 0
8/13/1999 238000 00
WD 1243 / 2026 Assessed:
407977
Building Value: 568300
1/1/1900 0
/ Ag.Credit:
0
Finished Area: 2151 SgFt
Exempt:
50500
Taxable:
357477
Proposed Tax:
7022.28
BUILDING INFORMATION
Exterior Features
3900
View:
Ocean
RoofCover:
-
RoofStruct: -
View
ExtType:
X057 - HBTSecConB12 YearBlt:
1999
Frame: -
Grade:
UD - UD
EffYrBit:
1999
PrimeWall: -
StoryHght:
0010 -1 Story
No.Units:
1
SecWall: -
Interior Features
Bed Rooms:
3
Electric:
-
PrmintWall: -
FullBath:
2
HeatType:
-
AvgHt/Fl:
1/213ath:
0
HeatFuel:
-
Prm.Flors: -
%A/C:
0
%Heated:
0
%Sprinkled: 0
Special Features and Yard Items
Land Information
Type Y/S
Qty. Units Qual.
Cond. YrBlt.
No. Land Use
Type Measure Depth
1 0400-Condo
115 -Unit 1
THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED
http://www.paslc.org/prc.asp?prclid=142380501080000 9/26/2007
-1-2-06-07;-.0.2:-23PM; EXPERT TERS 1 772 871 0990 # 15/ 19
- &O".Lix
War, L.VUL".w - bftlNw UUU
FILE # 313 '-etZ 1300K PAGE 260, Recorded 3.1/07/20, 10.50 AM
10-24-07;10:35AM:EXPERT MUTTERS ;1 772 871 0990
Thm -a-4pca hl* em Mdw ft b"MVw-% wK ba wifik cm =rj6- ad pevww, md k wmMsm WA Cmw7b.
0' 7
too A6"dhw MApoolwawo aftr.-.�
i in RqcA r,(J
7- f im" 11 ,f C--)
4%1;w 7Z. 110) W 7. M�zMubw
L in
713.13 AftitAUAWW=
LLM.
kid t.0
"x Ow"r 4w ZVI
!i= c:rFwlipi% I I
2;t. Lucie
ay-L-w 0' �d m
For—, (U—Urpq*n)
j.-.47
Ashloy L
mom vfNowy lh&k)
Q7.7-1&
or-com-ED
DEC Q 6 21007
PE . FIMIT'TlmG
St. LUe1pCounty,
Q
CO
Code Compliance Division
2300 Virginia Avenue
Ft. Pierce, FL 34982
Phone: (772) 462-1553 Fax: (772)
462-2522
Fees/Payments
Address 3880 N A1A
CityState / Zip FPR FL
Parcel #1423-805 0108-000/0 Jurisdiction CTY
suture Land Use Residential Medium Subdivision C
APPOPATI0,N. lNFQRMATI0N
Permit Type Storm Shutter
0709-0363 application Type Over the Counter Permit
Issued Activity Type
i
Code Type •;• Account •;•
IN
J' 1101 owner(s) (Lila M O'Leary
Unit #
Zoning' HIRD -ot # C�
Block
Other
Stories itomatic Sprinkler System? ❑
Fay Fee
Quantity Amount Date'Posted Paid? Now?
4 Receipt # Amount Date Posted
? 0000057913 $155.00 10/03/2007 Paid By EXPERT SHUTTER SERVICES INC ve
Payment Type CK •o+ Check (CK), Cash (CA),
•
Check # 18777 Mastercard (MC), Visa (VS) Fee
❖
Waived (FW), Refund (RF),
Credit Card Number Reversal (RV)
credit Card Authorization
Issued To EXPERT SHUTTER SERVICES
Received By gersteml
Date Paid 10/03/2007
---------------------
Fee Summary Total$ 155.00Total Pay erits$155.00 Balance$ 0.00
To refresh the balance, please click the
'Refresh Data' button at the top of the form
i
I
do
Code Compliance Division
2300 Virginia Avenue
Ft. Pierce, FL 34982
Phone: (772) 462-1553 Fax: (772) 462-2522
http://stiucleco.gov/ce
Date: 03 October 2007
Job Address: 3880 N AlA 1101
Received By: gersteml
Paid With: CK
Paid By: EXPERT SHUTTER SERVICES INC
Building
Receipt
Sign:
Receipt M
0000057913
'ermit Number:
SLC- 0709-0363
Amount:
$155.00
�redit Card Number:
Check Number:
18777
Code Compliance' Division
2300 Virginia Avenue
Ft. Pierce, FL 34982
Phone: (772) 462-1553 Fax: (772) 462-1148
http://stlucleco.gov/ce
BUILDING PERMIT
Issued: 10/03/2007 Conf #: 631 Permit #: SLC- 0709-0363
Job Location: 3880 N A1A 1101 City: FORT PIERCE
Permit Type: Storm Shutter
Job Description: INSTALL HURRICANE SHUTTERS FOR (2) OPENINGS.
Subdiv: Hibiscus by the Sea Condominium
Lot: Block: Parcel: 1423-805-0108-000/0
Page 1
Contractor HEISSENBERG MICHAEL P EXPERT SHUTTER SERVICES INC (772) 871-1915
1626 SW BILTMORE ST PORT ST LUCIE, FL 34984
Property Owner LILA M O'LEARY (772) 465-7059
3880 N A1A UNIT 1101 FORT PIERCE, FL 34949
Setbacks Left: Right:
Number of Units: 1.00 Floors: 1
Minimum Floor Elevation:
Job Value: $ 4,254.00
Front: Rear: Zoning: HIRD
Buildings: 1 Square Footage: 0.00
Flood Map: Flood Zone: Elev:
Permit holder acknowledges through acceptance of this permit that separate permits must be obtained as required by the Florida Building Code
including those for all electric, plumbing, mechanical, roofing, and structural work. Further, he/she acknowledges responsibility to comply with all
requirements of the 2004 Florida Building Code.
NOTICE: In addition to the requirements in this permit, there may be additional restrictions applicable to this property that may be found in the
records of this County, and there may be additional permits required from other governmental entities such as water management districts, state
agencies, or federal agencies. s:553.79(10), F.S.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR
BUILDING IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. s.713.135, F.S.
Christopher Lestrange
Building Official Date
For Automated Inspections, Call (772) 462-1261
For Questions, Call (772) 462-2172
St. Lucie County Land Development Code Section 11.05.01 (A) (2) states; Building Permits shall expire and
become null and void if work authorized by such Building Permit is not commenced, having called for and
received a satisfactory inspection, within six (6) months from the date of issuance of the permit, or if the
work is not completed within 18 months (permit by contractor) or 24 months (permit by owner) from the date
of issuance of the Building Permit.
GENERAL NOTES
FILE Copy
I. THE REQUIREMENTS OF APPROVAL DRAWING 05-364 ASSA/BERTHA HV ACCORDION SHUTTER BLADE HV #2 SHALL APPLY UNLESS
SPECIFIED OTHERWISE ON THIS DRAWING.
2. DESIGN LOADS FOR ROLL —UP SHUTTERS ARE. LOBBY ENTRY WEST (+56.2, —57.6 psf.) AND OPENINGS #2 (126" HIGH) +56.2, —5Z6
psf. & (102" HIGH) +58.8, —59.2 psf. INTERIOR ZONE 4. LOBBY ENTRY EAST (+55.5, —9Z4) AND OPENINGS #1 (126" HIGH) +56.2,
—99.4-psf. & (102" HIGH) +58.8, —106.5 psf. END ZONE 5. BASED ON 140 m.p.h. WIND SPEED, EXPOSURE C, GCpi=0.18; .Kd=O.85,
AND IMPORTANCE FACTOR I=1.00 IN ACCORDANCE WITH SECTION 1609 OF THE 2004 'FLORIDA BUILDING CODE WITH 2O05, 2006 AND
2007 SUPPLEMENTS.
i DESIGN LOAD INDICATED ABOVE SHALL ONLY BE USED FOR OPENINGS THAT BELONG TO THE CONDOMINIUM INDICATED BELOW.
4. ALL STRUCTURAL ALUMINUM EXTRUSION COMPONENTS ARE AS SPECIFIED ON THE APPLICABLE APPROVAL DRAWING (SEE NOTE 1) OR AS
INDICATED OTHERWISE ON THIS DRAWING.
5. CONTRACTOR TO VERIFY ALL DIMENSIONS AND WALL CONDITIONS AT SITE BEFORE PROCEEDING WITH THE WORK AND SHALL NOTIFY THIS
ENGINEER SHOULD ANY DISCREPANCIES BE FOUND THAT MIGHT ALTER THE .STRUCTURAL DESIGN OF THESE SHUTTERS.
6. CONTRACTOR TO VERIFY THE EXISTENCE OF ANY UTILITIES WHICH MAY INTERFERE WITH THIS CONSTRUCTION AND SHALL- NOTIFY THIS
ENGINEER SHOULD ANY ALTERATION BE NECESSARY.
7: THE INSTALLATION CONTRACTOR IS TO SEAL/CAULK ALL SHUTTER COMPONENT EDGES WHICH REMAIN IN CONTINUOUS CONTACT WITH THE
BUILDING TO PREVENT WIND/RAIN INTRUSION. '
8.. THIS ENGINEER IS NOT RESPONSIBLE FOR CONSTRUCTION SAFETY AT SITE WHICH IS THE CONTRACTOR'S RESPONSIBILITY.
SEE SCHEDULE ON SHEET 2 FOR OPENING INFORMATION.
/-a 0- rn%
S . LUCIE COUNTY
BUILDING DIVISION
REVI
FOR COMP AN
REVIEWED BY
DATE . o
PLAN AND PERMIT
MUST B KEPT ON JOB OR
NO INSPEC WILL BE MADE
CONCEALED FASTENERS OR ATTACHMENTS
ARE THE RESPONSIBIIJTY OF THE
CONNOTOR OF WOFM
IL ECO.NC.
TILLIT TESTING & ENGINEERING COM'
BJSS NW. JSN S6 sk. - iLCWN 64tm n
eJ0.9JE70 7 0006719f (J0.7J971-1d
WALTER A RLJT Jr. P. F
RORIDA Le. f 441R7
FLORIDA 'BUILDING CODE (Non High Velocity Hurricane Zone)
IN MMI 6F 81RIM .VACORN
RM ( )
fA2 EMI SI/ M SiR{� LIC
DRAWN er.
HIBISCUS I CONDOMINIUM
J990 NORTH A1A
fORT PIERCF. nORIDA J4949
09/21/07
DATE
07-241
DRAWING Na
an: x.
u!: w
muamx
a!r
-
-
SHEET ! OF 2
- -_---------_--._ .-------._THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
MAY�01 NECESSARY
IIWIT" A46 /h
N�LORDER TO 9%
/7L/7FV4e F11LD//(e7: N /N7^E/Lo2 Fjc/D
�oAfL:cA14.7o.ClF Zodle
29 4 33 8
710 LOBYENTdtY_ 3 7• 29 4 4 17
Q Ili 6 10 14,11 4. _
�p 6
4J N 6 18
8
10 73 50
0
8
•Q 5
?I 26
16 6
a
47 65 57 50 73
•10
SI
•. � _5n6g
LOGY ENTRY
N( \6 17 6," 1
� �1�GROUND FLOORS WINDOWS (RAN)A(RAN)I 6 17 6
Afx.o " �.VD iO,cl�
�p1L0 .?lJ.d$' //ILTEA2/6 •e ,20AA5 ''5V 9 / geve �,7/,Q /.�/T�"A2ld2 2.o.c1E' "flLP 20.iLE
4 33 6
FIOPENIN
4 29 710 3 2B 4 '4 1T
Aly 11 4 15 9 12 7 4 11 10 6 20
� 15 8
n 16 6.
OPENING #1 8
550 60 47 55 57 50 731.0
04 UNITS . .05 -UNITS
02 UNITS 03 UNITS OPENING #2.9 6 6 14 23 3�6 ., 65 8 9
28
4 25.
6 17
FLOORS 1 - 12 WINDOWS (PLA9)
T'HESg PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
MAY ICE NECESSARY IN ORDER TO
00MINY WITH AA AMICABLE CODES,
281 -1.
DESIGN WIND LOAD (pain AND CORRESPONDING MAXIMUM SHUTTER SPAN AND
ANCHORS SPACING (In) SCHEDULE FOR A GIVEN OPENING WCATION. FOR
CONCRETE INSTALLATIONS:
'
UNITS
SIZES
WIDTH x HGT,
DESIGN PRESSURES
END ZONE 5
'OPENINGS $1 (psf.)
DESIGN PRESSURES
INTERIOR ZONE 4
OPENINGS #2 (psf.)
ANCHOR SPACING
1/4"G TAPCON
ITW/SUILDEX
W/Q,1jB 3/4-
AIENTIN•
G
INSTALLATION
SHT. 22 OF 26
/ OWG.05-364.
$1 2
TOP BOT70M
LOBY WEST
270"x127"
---
+56.2 / -57.6
3'
LOGY EAST
382"x134"
+55.5 / -97.4
---
2 1/2'
#1201.
108"x126"
+56.2 / -99.4
+56.2 / -57.6
2 1/2 3'
1701 -
08"x�
+56.2 / -90.4'
-3:
,'•.•
'•001
�--108°fi102""
+58:8-106.8�'
+5B.8 /-59.23`1/�
4 1 2`
•
#901
1.08x102'
+58.8 / -106.5
+58.8 / -59.2
3 1/2" 4 1/2'
®
#801
108`xl02'
+58.6 / -106.5
+58.8 / -59.2
3 1/2 4 1/2'
#701
10B'x102'
+58.8 / -106.5
+58.8 / -59.2
#601
108"x102'.
+58.8 / -106.5
+58.8 / -59.2
#501
108"x102'
+58.8 / -706.5
+58.8 /•-59.2
3 1/2. 4 1/2"
#401
108'x102"
+58.8 / -106.5
+58.8 / -59.2
3 1/2 4 1/2"
#301
108"x102"
+58.8 / -106.5
+58.8 / -59.2
#201
1O8'x102'
+58.8. / -106.5
+58.8 / -59.2
pol
108"x126"
+56.2 / -99.4
+56.2 / -57.6
#1205
108"X126'
+56.2 / -99.4
+56.2 % -57.6
#1105
108"X126'
+56.2 / -99.4
+56.2 / -57.6
2 1/2" 3"
#1005
108'x102'
+58.8 / -106.5
+58.8 / -59.2
3
#905
108"x102"
+58.8 / -106.5
+58.8 / -59.2
J805
108"x102x
+58.8 / -106.5
+58.8 / -59.2
3 I/2
#705
106"x102"
+58.8 / -106.5
+58.8 / -59.2
#605
108'x102"
+58.8 / -106.5
+58.8 / -59.2
#505
108"x102"
+58.8 / -106.5
+58.8 / -59.2
3 1/2" 4 1 2"
0405
108'x102'
+58.8 / -106.5
+58.8 / -59.2'
3 1/2" 4 1 2"
#305
108"x102"
+58.8 / -106.5
+58.8 / -59.2
3 1/2" 4 1 2"
0205
108"xl26'
+56.2 / -99.4
+56.2 / -57.6
2 1/2" 3„
VA
FLORIDA BUILDING CODE (Non High Velocity Hurricane Zone)
WSIAdAI/BN Df BfRINA KY. ACCQRD�
l SEER
DRAWN 1
l.A
ILI
E C O rwe.
HIBISCUS I COMMMINIUM
JBRO NORTH AIA
FORT PISRCB fLORIDA J4949
' 09127107
DATE
07-241
DRAWINGNo
STING k ENGINEERING COMPANY
.� se st..roe, xrresvu uae0rs n .v�ae
(sosje7l-rsse , fa : (sw)ml-7e]i
E8-OOOB719
WALTER A 77LLIT Jr. P. E
FLORIDA Lie. 1T 44707
wn:
ursew,mx nur
Me
��
- -
-
-
2 Of 2
IzI
I
I9HEfT
CONCEhED_F���oRA�ac� FILE COPY
ARE THE AESPONSIBiIlIY OF THE