HomeMy WebLinkAboutSUBMITTED PAPERSDate. Fee Due: t Recei t# Permit #1 52f?)
St. Lucie County Building & Zoning
h -mac 2300 Virginia Avenue Ft. Pierce, FL 34982-5652 SCANNED
• z Tel.772-462-1553
��OR10p' St. Lucie County APPLICATION FOR ROOF PERMIT Ly
SEE REVERSE SIDE FOR I UCTIONS
1. Location/Site Address: q(00� S.ALEnO cnn
2. Parcel ID Number:�n` . (pM . (0 a.59• r)on • �7
Office Use I
Section
I Township
Range
I Map Page
I Zonin4l
Land Use
I Initials
Only
3. Description of Project or Work Activity: I clje• e)ee , A?e� T &494-
4. Total Roof Area (square feet): s or') 5. Roof Pitch: 1 Lm T
6. Type of Roof. ❑ Fiberglass Shingle ❑Barrel/Tile Ceramic ❑ Wood Shake Shingle
El Tar & Gravel RIModified Bitumen ❑ Metal
❑ Other (specify)
N.O.A — Product Approval required for All Types of Roofing Material
❑ All Commercial Roofing Requires Design by an Engineer or Architect (two Sets)
7. Owner Information 8. Contractor Information
Name: \.&IO --r FL Reg/Cert #: �� C • CI 3 ais 7c:? o
Address: '7 &02 69L,E,e,�tI ko • County Cert#: '_-201Q ff
City: f , ��j�' State: Business Name: . Ik .TAN U) E Ot` I D tj �--1
Zip: Phone: Phone (4(060- Lt ax L10- 839r/
o
9. Value of Construction: $ ) I q '40d
Note: Dry -in and Final Inspection Required.
Additional inspection may be required per Product Approval
OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is co t and t all work will be done
in compliance with all applicable laws regulating construction and mg.
CmD
PRINT QUALIFIERS/OWNERS NAME SIGNATURE OF QUALIFIER/OWNER
STATE OF FLORIDA, COUNTY OOF ,0 ►fit JUT LO CIE ACKNOWLEDGED BEFORE ME THIS 2_ DAY OF
20-4, BYWHO IS PERSOVKLLY KNOWN TO ME OR WHO HAS PRODUCED
�� AS IDENTIFICATION. NOTARY PUBLIC -STATE OF FLORIDA
,,rd,,e,lYeno �, t�l rJ Kare alb, Nielsen
SIGNATURE OF NOTARY TYPE OR PRINT NAME OF NOTARY
C, I W
Commission #DD551441
TITLE: NOTARY PUBLIC COMMISSION NUMBER Jam:) * iyComm. Expires: 06/12/2010
St. Lucie County Roof Permit Application rev. 7/18/05 ding
Code Compliance Division
2300 Virginia Avenue
Ft. Pierce, FL 34982
Phone: (772) 462-1553 Fax: (772) 462-2522
hdp://stiucieco.gov/ce
Date: 28 September 2007
Job Address: 7602 SALERNO RD
Received By: goycochb
Paid With: CK
Paid By: JA TAYLOR
Building
Receipt
Receipt#: 0000057741
'ermit Number: SLC- 0709-0383
Amount: $180.00
�redit Card Number:
Check Number: 43377
Sign:
r1.. •.--• -:...
Code Compliance Division
2300 Virginia Avenue
Ft. Pierce, FL 34982
Phone: (772) 462-1553 Fax: (772) 462-1148
hftp://Silucieco.gov/ce
INSPECTION CARD
Permit #: SLC- 0709-0383 Conf #: 593 Type: Roof
Issued 09/28/2007 Status: FIN Double Fee: No
Job Location 7602 SALERNO RD City, FORT PIERCE
Jurisdiction: St. Lucie County Lot: 3 " - Block: 69
Parcel: 1301-606-0259-000/7 Subdiv: Lakewood Park Unit 6
Flood: Elev: Flood Map:
Job Description: TEAROFF AND REROOF WITH MODIFIED BITUMEN - 500SF - FLAT
Setbacks Left:
Inspection Notes:
Right
Front
Rear,
Contractor TAYLOR CHAD G J A TAYLOR ROOFING INC (772) 466-4040
302 MELTON DR FT PIERCE, FL 34982
Property Owner EDWARD L WORTH JR (772) 461-0468
7602 SALERNO RD FORT PIERCE, FL 34951-1479
Property Owner DOLORES WORTH (772) 461-0468
7602 SALERNO RD FORT PIERCE, FL 34951-1479
SUB -PERMITS,'!.,
Permit # Status PT Cert # DBA 'Owner / Builder Job Description
INSPECTIONS - For Requests, Call: (772) 462-1261
Permit # Code Description
Priori Date Sched. Res Description
Inspector
Date Insp.
0709-0388 136 Roof Dry-in/Tin Tab
1 10/19/2007 90 Approved
Dave Johnson
10/19/2007
10/18/07 incall schedule with karen/ contr. bac
0709-0382 600 Product Certification
1 10/19/2007 90 Approved
Dave Johnson
10/19/2007
0709-0382 999 Final Inspection
2 10/31/2007 99 Final Approval
Jim Beams
10/31/2007
null
Scheduled: Tue Oct 30 09:44:13 EDT 2007 with value: Wed Oct 31 00:00:00 EDT 2007
Permit Nun 0709-0383
4P M I A M I•DADE
BUILDING CODE COMPLIANCE OFFICE (BCCO)
PRODUCT CONTROL DIVISION
NOTICE OF ACCEPTANCE (NOA)
Johns Manville Corporation
717 171h Street
Denver,. CO 80202
MIAMI-DADE COUNTY, FLORIDA
METRO-DADE• FLAGLER BUILDING
140 WEST FLAGLER STREET, SUITE 1603
MIAMI. FLORIDA 33130-1563
(305) 375-2901 FAX (305) 375-2908
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed by Miami -Dade County Product Control
Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and
other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right
to have this product or material tested for quality assurance purposes. If this product or material fails to
perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may
immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA
reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control
Division that this product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the High Velocity
Over Wood
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been
no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change
in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement
of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure
to comply with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,
then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No. 03-0212.01 and consists of pages 1 through 16.
The submitted documentation was reviewed by Jo e L. Acebo
i
�_i
Xiration Date: 06/14/1.1
Approval D�te:;.>
-- Page I_-of,_16
THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
COMPLY WITH ALL APPLICABLE CODES.
ROOFING ASSEMBLY APPROVAL
Category: Roofing
SuU_Cgtegonr. . APP Modified Bitumen
Deck Type: Wood
Maximum Design Pressure -52.5 psf
Fire Classification: See General Limitation #1
TRADE, NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test
Product
Product
Dimensions
. Specification
Description
JM APP Base
150 sq. ft. roll
ASTM D 5147
APP modified asphalt, fiberglass
reinforced, smooth surfaced base sheet.
APPeX 4S
32.8' x 3.28'; 90
ASTM D 6222,
APP modified asphalt, polyester
lb. roll
type I, grade S
reinforced, smooth surfaced membrane.
CA_ PPeX-4.SM _�
32.8' x 3.28'; 90
ASTM D 6222,
APP modified asphalt, polyester
lb. roll
type I grade G
reinforced, mineral surfaced membrane.
APPeX 4.5MFR 32.8' x 3.28'; 90 ASTM D 6222, APP modified asphalt, polyester
lb. roll type I grade G reinforced, -fire-retardant, mineral surfaced
membrane.
APPeX 180 32.8' x 3.28'; 90 ASTM D 6222, APP modified asphalt, polyester
lb. roll type I, grade G reinforced, smooth surfaced membrane.
Bicor. MFR 39-3/8" x 34' ASTM D 6223 APP modified asphalt, polyester / glass
reinforced, granule surfaced membrane.
Tricor MFR 39-3/8" x 34' ASTM D 6223 APP modified asphalt, polyester / glass
reinforced, granule surfaced membrane.
Bicor S 39-3/8" x 34' ASTM D 6223 APP modified asphalt, polyester / glass
reinforced, smooth surfaced membrane.
"Tricor S 39-3/8" x 34' ASTM D 6223 APP modified asphalt, polyester / glass
reinforced, smooth surfaced membrane.
PermaE1y-28� 36' x 108 ; ASTM D 4601 Type II asphalt impregnated and coated
72 lb. roll glass fiber base sheet
NOA No.: 06-0417.09
Expiration Date: 06/14/11
Approval Date:
Page 2 of 16
Product
Ventsulation
JM Topgard Type B
JM Fibrated Aluminum
Roof Coating
JM Premium Fibered
Aluminum Roof Coating
Test Product
Dimensions Specification Description
36" x 36' ASTM D 4897 I-[eavy duty fiber glass base sheet
Type II impregnated and coated on both sides with
asphalt with or without fine mineral
stabilizer.
APPROVED INSULATIONS:
ASTM D 1227 Fire rated, tibercd, non -asbestos, clay
water base asphalt emulsion.
ASTM D 2824 Fire rated, fibered, non -asbestos
aluminum coating.
ASTM D 2824 Fire rated, fibered, non -asbestos asphalt
aluminum coating.
TAat_.F 2
Product Name
Product Description
ENRGY 2, ENERGY 3, PSI-25
Isocyanurate Insulation.
ENRGY 2 Composite
Polyisocyanurate insulation laminated to
perlite.
ENRGY 2 Plus
Polyisocyanurate insulation laminated to
wood fiber.
Fesco Foam, DuraFoam
Isocyanurate Insulation with perlite facer
Retro-Fit Board, DuraBoard
A high -density perlite roof insulation.
Fesco Board
Rigid perlite roof insulation board.
Fiber Glass Roof Insulation
Fiberglas roof insulation.
ACFoam I1
Isocyanurate Insulation
Wood Fiberboard
Regular wood fiber insulation
High Density Wood Fiberboard
High Density Wood Fiber insulation board.
Perlite Insulation Board
Perlite Insulation
Type X Gypsum
Gypsum Wallboard
XPS
Extruded polystyrene
Stnictodeck
High Density Wood Fiber insulation board.
Manufacturer
(With Current NOA)
Johns Manville
Johns Manville
Johns Manville
Johns Manville
Johns Manville
Johns Manville
Johns Manville
Atlas Roofing Corp.
Generic
Generic
Generic
Generic
Generic
Masonite
NOA No.: 06-0417.09
Expiration Date: 06/14/11
Approval Date:
Page 3 of 16
APPROVED FASTENERS:
TABLE 3
Fastener Product
Product
Manufacturer
Number. Name
Description
Dimensions
(With Current NOA)
1. U1traFast
Insulation fastener for wood
Johns Manville
and steel.
2. UltraFast ASAP
Pre -assembled Insulation
Johns Manville
fastener and plate
3. U1traFast Metal Plate
Galvalume AZ55 steel plate
3" square &
Johns Manville
3" round
4. Olympic Fastener #12 &
Insulation fastener
Olympic Mfg. Group
#14
5. Olympic Fastener ASAP
Pre -assembled Insulation
Olympic Mfg. Group
fastener and plate
6. Olympic G-2.
Galvalume AZ55 steel plate
3.5" round
Olympic Mfg. Group
7. Olympic Standard
Galvalume AZ50 steel plate
3" round
Olympic Mfg. Group
8. Tru-Fast
Insulation fastener for steel
The Tru-Fast Corp.
and wood decks
9. Tru-Fast Plates
Galvalume AZ55 steel plate
3" round
The Tru-Fast Corp.
EVIDENCE SUBMITTED:
Test Agency
Test Identifier
Description
Date
Factory Mutual Research Corp.
J.I. OXOA9.AM
Wind Uplift
03/25/94
J.I. OW6A2.AM
Wind Uplift
02/05/93
J.I. OX7A4.AM
Wind Uplift
08/26/93
J.1. 3001482
08/11 /98
J.I. 3002823
04/01/99
J.I. 3003468
02/02/00
J.I. 3007148
04/ 19/00
3009499
4470
04/04/01
3011248
4470
11 /01/02
3012974
4450
06/03/02
Underwriters Laboratories, Inc.
R-10400 Published Annually
Exterior Research &.Design, LLC
#4361-2.04.97-1 TAS 114(J)
—Wind Uplift 04/15/97
10390A.12.97-1 TAS 114(J)
—Wind Uplift 12/15/97
10390A_10.97-1 TAS I
I4(J) — Wind Uplift
10/15/97
10391.01.03 TAS 114(J)
& TAS 117 (B) 01/29/03
NOA No.: 06-0417.09
Expiration Date: 06/14/11
Approval Date:
Page 4 of 16
.40
Membrane Type: APP
Beck Type 11: Wood, Non -Insulated
Deck Description: '9/32" or greater plywood or wood plank
System Type E: Base sheet mechanically fastened.
All General and System limitations apply.
'Base Sheet;ption #1) Or^e ply of JM APP Base, PermaPly 28, Glasbase Plus or
::�entsulation
mechanically fastened to the deck with JM U1traFast; Olympic or
Tni-Fast metal plates and fasteners at a 4" side lap 12" o.c. and two rows staggered
in the center of the sheet 18" o.c.
(Maximum Design Pressure —45 psf —See General Limitation #9.)
(Option #2) Minimum two plies of JM PermaPly 28 or Ventsulation
simultaneously fastened to the deck lapped 4" and fastened with approved roofing
nails and tin caps 9" o.c. at the lap and two rows staggered in the center of the
sheet 12" o.c.
(Maximum Design Pressure —52.5 psf— See General Limitation #7.)
(Option #3) Minimum.two plies of JM PermaPly 28 or Ventsulation
simultaneously fastened to the deck with JM Ultrafast fasteners and Metal Plates
spaced 9" o.c. in a 4" lap and 12" o.c. in two staggered rows in the center of the
sheet.
(Maximum Design Pressure—52.5psf—See General Limitation #7)
Ply Sheet:
(Optional) One or more plies of JM APP Base, APPeX 4S or APPeX 180 heat
welded to base sheet.
Membrane:
One or more plies of APPeX 4S, APPeX 180, APPeX 4.5M or APPeX 4.5 MFR
heat welded.
Surfacing:
(Optional) Install one of the following for all systems that do not achieve
acceptable fire ratings through the use of FR membrane sheets.
1. 400 lb./sq. gravel or 300 lb./sq. slag in a flood coat of approved mopping
asphalt at a rate of 60 lb./sq.
2. Karnak 97, Karnak 97 AF, Monsey Premium Long Life Aluminum Roof
Coating Asbestos Free or Monsey Prograde Aluminum, JM Topgard Type A,
Topgard Type B, JM Aluminum RF CT, Grundy AL MB aluminum coating at
a rate of 1-1/2 gal/sq Monsey Aquabrite, Gardner asphalt emulsion, APOC
Sunbright 400 or Henry 229 Aluminum Emulsion at 2'Y2 gal/sq or APOC 212
Aluminum Roof Coating at 3 gal/sq.
3. Grundy 20 F asphalt emulsion, Endure Asphalt Emulsion, APOC 302 or 302
AF applied at 2% gal/sq with optional 60 lbs./sq. of roofing granules
embedded in wet coating.
Maximmm Design
Pressure:
See Fastening Options Above
NOA No.: 06-0417.09
Expiration Date: 06/14/11
Approval Date:
Page 15 of 16
ft
WOOD DECK SYSTEM LIMITATIONS:
1 A slip slieet is required xvith PI} 4 and Ply 6 When used as a mechanically fastened base or anchor
sheet.
GENERAL. LIMITATIONS:
1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials
Directory for fire ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with
Product Control Approval guidelines. All other layers shall be adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., qr mechanically
attached using the fastening pattern of the top laver
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved
asphalt, panel size shall be 4' x 4' maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell
foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet
shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip
mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing
a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be
placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall
be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum
design pressure of -45 psf.
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of
275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value.
as field-tested, are below 275 lbf. insulation attachment shall not be acceptable.
6_ Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based
on a minimum fastener resistance value in conjunction with the maximum design value listed within
a specific system. Should the fastener resistance be less than that required, as determined by the
Building Official, a revised fastener spacing, prepared, signed and scaled by a Florida Registered
Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing
shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and
calculations in compliance with Roofing Application Standard RAS 117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these
areas. Fastener densities shall be increased for both insulation and base sheet as calculated in
compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed
by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant
(When this limitation is specifically referred within this NOA, General Limitation #9 will not
be applicable.)
8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs
shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e.
field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for
enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners).
(When this limitation is specifically referred within this NOA, General Limitation #7 will not
be applicable.)
END OF THIS ACCEPTANCE
NOA No.: 06-0417.09
Expiration Date: 06/14/11
Approval Date:
Page 16 of 16