Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SUBMITTED PAPERS
CdCI T��" F L O R t D A 4. 5. Name: Address: City: Phone: SCANNED BY St. Lucie County Permit Number: 0 DI '01 -D[13() St. Lucie County Building & Zoning Department 2300 Virginia Avenue Fart Pierce, FL 34982 772-462-1553 APPLICATION FOR STORM SHUTTER PERMIT n SECT 1 31 TWP 34S RNG 40E MAP ZNC I LU I 1NIT SEE REVERSE SIDE FOR INSTRUCTIONS DATE: LOCATION/SITE ADDRESS: 4804 El Nueva Ave Ft. Pieme, FL 32946 PARCEL ID NUMBER: 1431-703-0028-000-7 DESCRIPTION OF PROJECT OR WORK ACTIVITY: TYPE OF STRUCTURE: SFR V OWNERS INFORMATION Addition OTHER 6. CONTRACTORS INFORMATION FL REG/CERT #: CGC1507622 COUNTY CERT #: 4804 El Nueva Ave State: Business Name: Ft. Pierce FL Zip: 772-489-0776 32946 Home Safety Solutions Fred R. Bohen Type of Surface attachment: Wood Frame _ Concrete _ Masonry _ Other Product Type Minimum Design Pressure Product Compliance Report # Method of Attachment Asper 1707.4.4.1 FBC 120 mph 130 mph 140 mph 140 Exp. C SBCCI Dade Other Anchor Type Anchor Spacing Impact Glazing Removable Panels Accordion Roll U Colonials Other ALL PRODUCTS SHALL BE LABLED SBCCI OR DADE COUNTY FOR DETERMINING IMPACT RESISTANCE FROM WIND BORNE DEBRIS. *"SEE FINAL INSPECTION PROCEDURE FOR EXISTING RESIDENTIAL STRUCTURES ON BACK 7. VALUE OF CONSTRUCTION: $ 2,833 FEES DUE: RECEIPT: OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in compliance with all applicable laws regulating construction and zoning. r Rj_ R PRINT QUALIFIERS/eWNER9z AIME SIGNATURE OF QUALIFIER/@1Y piQ LKK' STATE OF FLORIDA, COUNTY - OF ^ t p�°� ACKNOWLEDGED BEFORE ME Tt11S IN DAY OF �L R • hSAA-9-h umeanoeuu►i16�CiBiii��umu 200t, WI10 IS PERSONALLY KNOWN TOME OR WHO HAS PRODUCED CHIZIS 1'ABE! SLOAN *%%%ly n'w Comm# DD0711254 SIGNATURE OF NOTARY TYPE OR PRINT NAME OF NO TITLE: NOTARY PUBLIC COMMISSION NUMBECi Mores 914/2011 nfi` Fbft NotaryAsm..Inc NOTICE TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU'��A'Ylf�tl�..... TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Permit Number: 0$1Z (t 3b St. Lucie County Building & Zoning Department 2300 Virginia Avenue Fort Pierce, FL 34982 772-462-1553 APPLICATION FOR STORM SHUTTER PERMIT SECT 1 31 1 TWP 34S RNG 40E I MAP 4 ZNG Q C �k LU INIT SEE REVERSE SIDE FOR INSIRUUFIONS 11A 1 L' : 1. LOCATION/SITE ADDRESS: 4804 El Nueva Ave, Ft. Pierce, FL 32946 2. PARCEL ID NUMBER: 1431-703-0028-000-7 3. DESCRIPTION OF PROJECT OR WORK ACTIVITY: Accordion shunter st, orm panels 4. TYPE OF STRUCTURE: SFR ✓ 5. OWNERS INFORMATION Name: Address: 4804 El Nueva Ave City: State: Ft. Pierce FL Addition OTHER Phone: Zip: 772-489-0776 32946 Type of Surface attachment: Wood Frame Concrete 6. CONTRACTORS INFORMATION FL REG/CERT #: CGC1507622 COUNTY CERT #: „ Ai7 Business Name: HomeSafety Solutions Fred R. Bohen Masonry _ Other Product Type Minimum Design Pressure Product Compliance Report # Method of Attachment As per 1707.4.4.1 FBC 120mph 130 mph 140 mph 140 Exp. C SBCCI Dade Other Anchor Type Anchor Spacing Impact Glazing SEE TTACE JED Removable Panels Accordion Roll U Colonials Other ALL PRODUCTS SHALL BE LABLED SBCCI OR DADE COUNTY FOR DETERMINING IMPACT RESISTANCE FROM WIND BORNE DEBRIS. ;'*SEE FINAL INSPECTION PROCEDURE FOR EXISTING RESIDENTIAL STRUCTURES ON BACK 7. VALUE OF CONSTRUCTION: $ 2,833 FEES DUE: RECEIPT: OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in compliance with all applicable laws regulating construction and zoning. Samuel Smith MSFH2O4596 `�-- PRINT QUALIFIERS/OWNERS NAME SIGNATURE OF QUALIFIER/OWNER 4 l"IA STATE OF FLORIDA, COUNTY OF 9ACKNOWLEDGED BEFORE ME Tins 21 DAY OF 9549Mt7�, 20p.&-. WHO IS i PERSONALLY KNOWN 7'O ME OR WHO HAS PRODUCED AS IDENTIFI2rlg u���.Px � A' rsneuyyuq�d'�? ei H5 n e nt R ageonnnouoa000m � A ® xarrN,. Comm# DD0711254 a SIGNATURE OF NOTARY TYPE OR PRINT NAME OF NOTARY TITLE: NOTARY PUBLIC COMMISSION NUMBER Expires 9/4/2011 Florida Notary Assn., Inc NOTICE TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RE S 4° Y !di�9I9°RRYINiiene... Q..ennnn uo TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. a Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-2172 Fax: (772) 462-6443 hftp://www.stlucieco.org/public—works/permitting.htm Issued: 01 /08/2009 Job Location: 4804 EL NUEVA AVE Permit Type: Storm Shutter Job Description: BUILDING PERMIT Page 1 Conf #: 856 Permit #: SLC- 0812-0130 City: FORT PIERCE INSTALLATION OF 1- ACCORDION SHUTTER 14- STORM PANELS WOOD FRAME FOR SINGLE FAMILY RESIDENCE S/D Harmony Heiqhts No. 3 Lot: 7 Block: Parcel: 1431-703-0028-000/7 Contractor FRED RUSSELL BOHEN HOME SAFETY SOLUTIONS INC (813) 814-2236 704 STEVENS AVE Property Owner SAMUEL L SMITH OLDSMAR , FL 34677 (772) 489-0776 4804 EL NUEVA AVE FORT PIERCE, FL 34946-1009 Property Owner SHIRLEY A SMITH (772) 489-0776 4804 EL NUEVA AVE FORT PIERCE, FL 34946-1009 Setbacks Left: Number of Units: 1.00 Minimum Floor Elevation: Right: Front: Rear: Floors: 1 Buildings: 1 Flood Map Flood Zone: Zoning: RS-4 Square Footage: 0.00 Elev: Permit holder acknowledges through acceptance of this permit that separate permits must be obtained as required by the Florida Building Code including those for all electric, plumbing, mechanical, roofing, and structural work. Further, he/she acknowledges responsibility to comply with all requirements of the 2004 Florida Building Code. NOTICE: In addition to the requirements in this permit, there may be additional restrictions applicable to this property that may be found in the records of this County, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. s:553.79(10), F.S. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR BUILDING IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. s.713.135, F.S. Christopher Lestrange Building Official Date For Automated Inspections, Call (772) 462-1261 For Questions, Call (772) 462-2172 St. Lucie County Land Development Code Section 11.05.01 (A) (2) states; Building Permits shall expire and become null and void if work authorized by such Building Permit is not commenced, having called for and received a satisfactory inspection, within six (6) months from the date of issuance of the permit, or if the work is not 'completed within 18 months (permit by contractor) or 24 months (permit by owner) from the date of issuance of the Building Permit. EDWIN M. FRY, Jr., CLERK OF THE CIRCUIT COURT - SAINT LUCIE COUNTY FILE # 3276371 07-1?')OK 3030 PAGE 2883, Recorded 11/05/20^." c-Lt 12:42 PM AFTER REMRDINGRRTURN TO: FkX1Art NLMRER: y1 This Spam I. M mar�for m-rdlna Into NOTICE OF COMWENCEMENT The undersigned hereby given notice that improvement will be made to certain real property, and in auzmhmce with Chapter 713, Florida statutes the following information is provided in the Notice of commencement. 1. DESCRIPTION OF PROPERTY (Legal description and street address) TAX FOLIO NUMBER 1-703-0028-000-7 SUBDIVMON BLOCK_b TRACT LOT--j_BLDG UNIT 1920 SW Taurus Ln 1431-703-0028-000-7 2. GENERAL DESCRIPTION OF uwRovEMENT: Acccordion Shutter, Storm panels 3. OWNER INFORMATION: a. Name Samuel Smith MSFH2O4596 b. Address 4804 El Nueva Ave, Ft. Pierce, FL 32946 C. interest in property d. Name and address of fee simple titleholder (if other than owner) 4. CONTRACTOR'S NAME, ADDRESS AND PHONE NUMBER: 44, d l_197 S/Efg—,q 5oLU -rL Q r,uS 704 Stevens Avenue. Oldsmar —FL 34677 Phone: S. SURETY'S NAME, ADDRESS AND PHONE NUMBER AND BOND AMOUNT: 6. LENDER'S NAME, ADDRESS AND PRONE NUMBER: 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13 (1 xa) 7., Florida Statutes: NAME ADDRESS AND PHONE NUMBER: 8. In addition to himself or herself, Owner designates the following to receive a copy of the Lienor's Notice as provided in Section 713.13 (lxb), Florida Statutes: NAME, ADDRESS AND PHONE NUMBER: 9. Expiration date of notice of commencement (the expiration date is 1 year from the date of recording unless a different date is specified) . 20 . Signature of owner or Print Name and Provide Signatory's Title/Office Ownces Authorized Olncer/Dlrector/Partner/Msnager State of Florida County of St. Lucie m / �n� `� The e fo oing instrument was a)mowl ed before me this o - day of OC U� 2001 1 By (Printed name of person signing above) (Type of authority... e.g.-Owner, officer, trustee, attorney in fact) on bebalf of wham instr=ent was omuted) Personally Known_ A • t!✓� (Printed Name of Notary Public) MY Under penalties of perjury•, I declare that I have react the foregoing and that the facts in it are true to the best of my knowledge and belief (section 92.525, Florida Statutes). Signatures) of Owner(s) or/Owneer%(s)' Authorized 01Hcer/Director/Pattner/Manageerwwhho signed above: By: .15E5Ly, ��_ By Lien l'/-ti / /'4+ -eti. ar.oannoa,� (Sipature) (Printed Name) STATE OF FLORIDA� ST. LUCIE COUNTY �-- e, THISTOCERTIFY T;`RTTHIS ISA00 TRUE �. - C0RFREO' 0,0Py OF THE G� E ' 4'l ' i „^FAY, JR., CLERK 1/ .7 �.���:t �•t jl erk l\\\ ��F,couis�` HOME 7134 SAFETY Oldsmar, tFL 34677 Fax (813) 814 2237 SOLUTIONS wwmhurricanesos.com CGC1507622 Property Information Owner: Samuel Smith MSFH2O4596 Address: 4804 El Nueva Ave Ft. Pierce, FL 32946 Building Information Wind Zone: 140 MPH. Exposure Category: B Minimum Building Dimension: 45 ft. Mean Roof Height: 18 ft. Structure Category: II 1� Design Pressure Calculations JI Opening Location Device Device Device Max Positive Max Negative Number Zone Width (in) Height (in) Elevation (ft) Pressure (psf) Pressure (psf) 1 Cr- Int 36 80 7 33.6 -36.6 2 Int 36 50 7 34.7 -37.7 3 11 Int 89 49 7 32.7 -35.7 4 , i Int 23.5 27.5 7 35.2 -38.2 5 o Int 36 50 7 34.7 -37.7 6 k Int 36 81 7 33.6 -36.6 7 Int 73 51 7 33.1 -36.0 8 t, Int 73 50 7 33.1 -36.1 9 tl: Int 37 82 7 33.5 -36.5 10 < < Int 36 50 7 34.7 -37.7 11 1 ` Int 36 50 7 34.7 -37.7 12 it Int 36 38 7 35.2 -38.2 13 Int 36 38 7 35.2 -38.2 14 ` Int 36 50 7 34.7 -37.7 15 << Int 36 37 7 35.2 -38.2 F I L E x � PY 1 Page 1 of 1 IIOpening Schedule II Product Type Size(wxh) 1. ACC 36x80 2. F/S 36x50 3. F/S 89x49 4. F/S 23.5x27.5 5. F/S 36x50 6. F/S 36x81 7. F/S 73x51 8. F/S 73x50 9. F/S 37x82 10. F/S 36x50 11. F/S 36x50 12. F/S 36x38 13. F/S 36x38 14. F/S 36x50 15, F/S 36x37 11 10 7 o a) 6 ro CO) c 5 Submission 11 S - —1 INDICES SHEET 1- INDICES, GENERAL NOTES, TYPICAL ELEVATION, ALLOWABLE BLADE PRESSURE TABLE 1 SHEET 2- SECTIONS AA, BB & CC, ANCHOR TABLES SHEET 3- SECTIONS DD, EE & FF, ANCHOR TABLES SHEET 4- SECTIONS GG, J, H. I & ANCHOR, TABLES SHEET 5- SECTION L, MALE & FEMALE STACK SHEET 6- BILL OF MATERIALS, COMPONENTS DRAWINGS & ASSEMBLY LAY -OUT. 1- DEFINITION, THIS PRODUCT IS AN ACCORDION TYPE SHUTTER) DESIGNED, CONSTRUCTED AND ERECTED TO EASILY ENCLOSE AN OPENING, PROVIDING PROTECTION FROM HURRICANE FORCE WTPIDS AND WIND BORNE DEBRIS CLARGE. MISSILE) WITHIN THE ALLOWABLE DESIGNED PRESSURES AND LIMITATIONS STATED IN THIS APPROVAL. 2- CODE- THIS PRODUCT HAS BEEN TESTED AND DESIGNED IN ACCORDANCE WITH THE 2004 FLORIDA BUILDING CODE (TAS 201, 202 AND 203).2006 SUPPLEMENT _ 3- POSTING A PERMANENT LEGIBLE DECAL SHALL BE PLACED AT READILY VISIBLE LOCATION STATING THE FOLLOWING 'CROCI NORTH AMERICA - FT, MYERS - FLORIDA CROCI EXTRUDED ALUMINUM ACCORDION SHUTTER' 4- LOADS- THE DESIGNED LOAD (BASED ON ASCE 7) MUST BE CALCULATED BY A PROFESSIONAL ARCHITECT OR ENGINEER FOR EACH SPECIFIC PROJECT. THE CALCULATED DESIGNED PRESSURE MUST NOT EXCEED THE ALLOWABLE PRESSURES FOR EACH SHUTTER COMPONENT TO BE USED. 5- MATERIALS ALL EXTRUDED ALUMINUM SHAPES SHALL BE MADE OF 6063-T6 OR AS NOTED. 6- FASTENERS, ASSEMBLY SCREWS AND ANCHORS SHALL BE AS SPECIFIED IN THE CURRENT SET OF DRAWINGS. INSTALLATION AND LOADS AS PER THIS APPROVAL. 7- USE, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR, ARCHITECT OR ENGINEER OF RECORD TO VERIFY THE FOLLOWING, 7. 1- THE STABILITY OF THE STRUCTURE WHERE THE SHUTTER IS TO BE ATTACHED INSURING PROPER ANCHORAGE, 7. 2- THE SITE SPECIFIC PROJECT CRITERIA SUCH AS BUT NOT LIMITED TO WINDLOADS, LOCAL CODE REQUIREMENTS, DESIGNED PRESSURES ETC. 7. 3- THAT THIS APPROVAL IS ADEQUATE TO THE SPECIFIC PROJECT, 8- 33 I/3% INCREASE IN ALLOWABLE _GADS HAVE NOT BEEPI USED IN THE DESIGN OF THE ANCHORS FOR THIS PRODUCT --1,PPROVAL, HOWEVER, WOOD ANCHORS WITH 1.33 LOAD DURATION NCREASE FOR WIND LOAD HAVE BEEN USED. TYPICAL ELEVATION A.8.C,D.F.F r Y U to t5 o W ~ � L U � t z H, I, J MW a W � � 1 H T A,B,C,D,E,F,C LSHUTTER WIDTH (SW) I Hn I uITTATIMM USER INSTRUCTIONS: 1- DETERMINE PROJECT DESIGN WIND LOAD PRESSURES AS PER ITEM 4 OF GENERAL NOTES, SHEET 1. 2- CHECK BLADE SIZE WITH TABLE I ON SHEET 1 FOR ALLOWABLE DESIGN PRESSURE. 3- SELECT MOUNT TYPE: TO BE USED AS PER SHEETS 2, 3 & 4. MOUNT TYPES ARE INTERCHANGEABLE. 4- CALCULATE ANCHOR SPACING AND TYPE OF ANCHOR TO BE USED FOR A GIVEN BLADE SIZE X PRESSURE FOR THE SPECIFIC MOUNT TYPE AS PER SHEETS 2, 3 & 4. TABLE 1 ALLOWABLE DESIGNED LOADS X MAXIMUM BLADE SIZE BLADE (IN) PRESSURE (PSF) INCHES POSITIVE NEGATIVE 0' 188 B 66' 171 71 1 14 14 117 ru- -TUB_r__0 1 144' 46 56 . !aaS 3M 5" 3/8' N c GLASS a scrxR:.nw 3/6'1 GLASS SEPARATION INSTALLATION BELOW 30' ELEVATION BLADE <=120' 3 1/2' BLADE >120' 4 5/8' INSTALLATION ABOVE 30' ELEVATION BLADE <=120' 3' BLADE >120' 4' Manufacturer: Croci North America 6360 TOPAZ COURT FORT MYERS, FL 33912 Tel.: (239) 278-3066 Fax: (239) 278-5977 Engineering: +Enr�C2n +lztr. CA 8116 6971 W. Sunrise Blvd. 104 Plantation, FI. 33313 Tel.: (954) 585-0304 AD uj (.np1AA6t'�`� 1 P dro DPF�Qiiiedo " 7E�i360�1- Daie: 11/15/06 Scale: NA Design by: PPMF Revision: Drawing Number 06-342 Sheef 1 of 6 SECTION AA BUILT —OUT ON ANGLE 1/4-105/8' SIDS OR 1/4-204/4' PHMS W/NUT 12'oc FOR LO;A➢S <- 80 PSF 61oc FOR LOADS > 80 PSF j7 ANCHORS SPACED PER TABLE CAS AA BELOW l3 ^1s \ 12 ` L2 16 Q2 wa o rn rn ,- 3 �Q � W �w 1s i a z jll 2 wQ r 214 f � wa l5 TA4MSC7p-0ERSTASP"EC r1 ED 13 AA BELOW 11/4-14X5/8' SDS OR /4-20x3/4' PHNS W/NUT 12'oc FOR LOADS <= 80 PSF 6'oc FOR LOADS > 80 PSF _CTION MAXIMUM ANCHOR SPACING INCHES ON CENTER d p sf � ��tCi,ti�tl>• 4 i�!�[Y��JIYaIY'�fillt��l�lFdllY�M.t�E� G6-E�7�tJt]!r]�']fI�1lY>tl1�Jt]lY�lCdI�JlY� ALTERNATE SECTION BB BUILT —OUT ON ANGLE 1/4-105/8' SDS OR 1/4-200/4' PHNS W/NUT 12'oc FOR LOADS (= 80 PSF 6'oc FOR LOADS > 80 PSF 17 13 m m 16 2 ANCHORS SPACED AS PER TABLE BS BELOW ��-is cwi WQ 13 p 0 17 i� Q N ANCHORS SPACED L '-AS PER TABLE L/4-14X5/8' SDS OR BB BELOW 1/4-20x3/4' PHNS W/NUT 12'oc FOR LOADS <= 80 PSF 6'oc FOR LOADS > 80 PSF SECTION BB - MAXIMUM ANCHOR. SPACING INCHES ON CENTER AFF 611V1 �ilt]��.lk�']��fIIJE�.'•1�71.C�!!lt7lY�l�t-�<�]!t� '�ILasf��tl��E]Rff�f/t]�lBi�l tFS�]mmQimmQiCa®�lmm<!/:lCiiti SECTION CC WALL MOUNT TRACK 1, IA, 12 Manufacturer: Croci North America 6360-TOPAZ COURT ANCHORS SPACED FORT MYERS, FL 33912 AS PER TABLE CC Tel.:. (239 278-3066 BELOW Fax: (239) 278-5977 MM> TWO ROWS OF ANHORS IN -LINE Product: Croci Extruded ® W Aluminum yU �U Accordion Shutter Wz Q F W" ..Q EngTv Jnr. a m CA 8116 69711 W. Sunrlse Blvd. 104 WL Plantation, FI. 33313 w ¢ Tel.: (954) 585-0304 3 .� is vA=4,GVElF.f:�4'r,� + TWO ROWS �.E.9� . s OF ANHORS , �U Or' , 15 IN -LINE l3 i A ., i tiil : O j 1, IA, lB ANCHORS SPACED �,n�i(+,1. AS PER TABLE CC Enp�n 'F FSedl BELOW Pod ro e'►iguelndo PE 52609 SECTION CC - MAXINUN ANCHOR SPACING INCHES ON CENTER Date: 11/15/06 LABE IZ CIN> Scale: NA Design by: PPMF � Revislon: CF3fltlll Iil- C�f�C`3fC�'i�3! iS]AEUti�wr7ma�>or�im�a>tr�m� � �t]lJlSff/LfIS]R;JE7l�lllt]C3fE�R�lY3l art,;•ti�In�]LfOQ9ttyt[�7�ra�/L1li-7E]E7�1 w1imOf/miiWON WINWW&U ANCHOR DESCRIPTION EMBED, Manufacturer Ede Dist. a con to o nin• si concrete CO / n on 1n o 0 ow oc co / cew" sTDnn "531M - 0 Ca -in Into nin, D00 S1 Concre aPowers 3. Drawing Number 06-342 Sheet 2 of 6 . ALTERNATE SECTION BB BUILT —OUT ON ANGLE 1/4-105/8' SDS OR 1/4-200/4' PHNS W/NUT 12'oc FOR LOADS (= 80 PSF 6'oc FOR LOADS > 80 PSF 17 13 m m 16 2 ANCHORS SPACED AS PER TABLE BS BELOW ��-is cwi WQ 13 p 0 17 i� Q N ANCHORS SPACED L '-AS PER TABLE L/4-14X5/8' SDS OR BB BELOW 1/4-20x3/4' PHNS W/NUT 12'oc FOR LOADS <= 80 PSF 6'oc FOR LOADS > 80 PSF SECTION BB - MAXIMUM ANCHOR. SPACING INCHES ON CENTER AFF 611V1 �ilt]��.lk�']��fIIJE�.'•1�71.C�!!lt7lY�l�t-�<�]!t� '�ILasf��tl��E]Rff�f/t]�lBi�l tFS�]mmQimmQiCa®�lmm<!/:lCiiti SECTION CC WALL MOUNT TRACK 1, IA, 12 Manufacturer: Croci North America 6360-TOPAZ COURT ANCHORS SPACED FORT MYERS, FL 33912 AS PER TABLE CC Tel.:. (239 278-3066 BELOW Fax: (239) 278-5977 MM> TWO ROWS OF ANHORS IN -LINE Product: Croci Extruded ® W Aluminum yU �U Accordion Shutter Wz Q F W" ..Q EngTv Jnr. a m CA 8116 69711 W. Sunrlse Blvd. 104 WL Plantation, FI. 33313 w ¢ Tel.: (954) 585-0304 3 .� is vA=4,GVElF.f:�4'r,� + TWO ROWS �.E.9� . s OF ANHORS , �U Or' , 15 IN -LINE l3 i A ., i tiil : O j 1, IA, lB ANCHORS SPACED �,n�i(+,1. AS PER TABLE CC Enp�n 'F FSedl BELOW Pod ro e'►iguelndo PE 52609 SECTION CC - MAXINUN ANCHOR SPACING INCHES ON CENTER Date: 11/15/06 LABE IZ CIN> Scale: NA Design by: PPMF � Revislon: CF3fltlll Iil- C�f�C`3fC�'i�3! iS]AEUti�wr7ma�>or�im�a>tr�m� � �t]lJlSff/LfIS]R;JE7l�lllt]C3fE�R�lY3l art,;•ti�In�]LfOQ9ttyt[�7�ra�/L1li-7E]E7�1 w1imOf/miiWON WINWW&U ANCHOR DESCRIPTION EMBED, Manufacturer Ede Dist. a con to o nin• si concrete CO / n on 1n o 0 ow oc co / cew" sTDnn "531M - 0 Ca -in Into nin, D00 S1 Concre aPowers 3. Drawing Number 06-342 Sheet 2 of 6 . �ilt]��.lk�']��fIIJE�.'•1�71.C�!!lt7lY�l�t-�<�]!t� '�ILasf��tl��E]Rff�f/t]�lBi�l tFS�]mmQimmQiCa®�lmm<!/:lCiiti SECTION CC WALL MOUNT TRACK 1, IA, 12 Manufacturer: Croci North America 6360-TOPAZ COURT ANCHORS SPACED FORT MYERS, FL 33912 AS PER TABLE CC Tel.:. (239 278-3066 BELOW Fax: (239) 278-5977 MM> TWO ROWS OF ANHORS IN -LINE Product: Croci Extruded ® W Aluminum yU �U Accordion Shutter Wz Q F W" ..Q EngTv Jnr. a m CA 8116 69711 W. Sunrlse Blvd. 104 WL Plantation, FI. 33313 w ¢ Tel.: (954) 585-0304 3 .� is vA=4,GVElF.f:�4'r,� + TWO ROWS �.E.9� . s OF ANHORS , �U Or' , 15 IN -LINE l3 i A ., i tiil : O j 1, IA, lB ANCHORS SPACED �,n�i(+,1. AS PER TABLE CC Enp�n 'F FSedl BELOW Pod ro e'►iguelndo PE 52609 SECTION CC - MAXINUN ANCHOR SPACING INCHES ON CENTER Date: 11/15/06 LABE IZ CIN> Scale: NA Design by: PPMF � Revislon: CF3fltlll Iil- C�f�C`3fC�'i�3! iS]AEUti�wr7ma�>or�im�a>tr�m� � �t]lJlSff/LfIS]R;JE7l�lllt]C3fE�R�lY3l art,;•ti�In�]LfOQ9ttyt[�7�ra�/L1li-7E]E7�1 w1imOf/miiWON WINWW&U ANCHOR DESCRIPTION EMBED, Manufacturer Ede Dist. a con to o nin• si concrete CO / n on 1n o 0 ow oc co / cew" sTDnn "531M - 0 Ca -in Into nin, D00 S1 Concre aPowers 3. Drawing Number 06-342 Sheet 2 of 6 . SECTION CC WALL MOUNT TRACK 1, IA, 12 Manufacturer: Croci North America 6360-TOPAZ COURT ANCHORS SPACED FORT MYERS, FL 33912 AS PER TABLE CC Tel.:. (239 278-3066 BELOW Fax: (239) 278-5977 MM> TWO ROWS OF ANHORS IN -LINE Product: Croci Extruded ® W Aluminum yU �U Accordion Shutter Wz Q F W" ..Q EngTv Jnr. a m CA 8116 69711 W. Sunrlse Blvd. 104 WL Plantation, FI. 33313 w ¢ Tel.: (954) 585-0304 3 .� is vA=4,GVElF.f:�4'r,� + TWO ROWS �.E.9� . s OF ANHORS , �U Or' , 15 IN -LINE l3 i A ., i tiil : O j 1, IA, lB ANCHORS SPACED �,n�i(+,1. AS PER TABLE CC Enp�n 'F FSedl BELOW Pod ro e'►iguelndo PE 52609 SECTION CC - MAXINUN ANCHOR SPACING INCHES ON CENTER Date: 11/15/06 LABE IZ CIN> Scale: NA Design by: PPMF � Revislon: CF3fltlll Iil- C�f�C`3fC�'i�3! iS]AEUti�wr7ma�>or�im�a>tr�m� � �t]lJlSff/LfIS]R;JE7l�lllt]C3fE�R�lY3l art,;•ti�In�]LfOQ9ttyt[�7�ra�/L1li-7E]E7�1 w1imOf/miiWON WINWW&U ANCHOR DESCRIPTION EMBED, Manufacturer Ede Dist. a con to o nin• si concrete CO / n on 1n o 0 ow oc co / cew" sTDnn "531M - 0 Ca -in Into nin, D00 S1 Concre aPowers 3. Drawing Number 06-342 Sheet 2 of 6 . � Revislon: CF3fltlll Iil- C�f�C`3fC�'i�3! iS]AEUti�wr7ma�>or�im�a>tr�m� � �t]lJlSff/LfIS]R;JE7l�lllt]C3fE�R�lY3l art,;•ti�In�]LfOQ9ttyt[�7�ra�/L1li-7E]E7�1 w1imOf/miiWON WINWW&U ANCHOR DESCRIPTION EMBED, Manufacturer Ede Dist. a con to o nin• si concrete CO / n on 1n o 0 ow oc co / cew" sTDnn "531M - 0 Ca -in Into nin, D00 S1 Concre aPowers 3. Drawing Number 06-342 Sheet 2 of 6 . ANCHOR DESCRIPTION EMBED, Manufacturer Ede Dist. a con to o nin• si concrete CO / n on 1n o 0 ow oc co / cew" sTDnn "531M - 0 Ca -in Into nin, D00 S1 Concre aPowers 3. Drawing Number 06-342 Sheet 2 of 6 . Drawing Number 06-342 Sheet 2 of 6 . SECTION DO INSET MOUNT ,CED AS DO BELOW ANCHOR SPACED AS PER TABLE DO BELOW (ED) EDGE DISTANCE SECTION DD - MAXIMUM ANCHOR SPACING INCHES ON CENTER sf 6 i ■:!lCtILLf L'1lf:T<J4�t7L'I141<1f:Llf:1lLL•] 4L8f:1lG'k]L'Llj OOOOOOOiO�oo���.7� SECTION EE (ED) INSET MOUNT r13 WN N W a �(ED) EDGE DISTANCE ANCHOR SPACED AS PER TABLE EE BELOW SECTION EE - MAXIMUM ANCHOR SPACING INCHES ON CENTER NI AM t? 7F e IN) OR SPACED AS C TABLE EE BELOW SECTION FF INSET MOUNT (ED) EDGE DISTANCE 1.000 t— 1/4-2x3 6063-T6 ALUMINUM ANGLE MIN. 0.500 H/4-105/8' SDS OR /4-20x3/4' PHHS W/NUT 2'oc FOR LOADS <= 65 PSF 6'oc FOR LOADS > 65 PSF MIN. 0.500 1111R!•17 wff� .� L• 1! fkJ LL f T:}! f:K] f:L f G!! GI•I f3 f Gl! T:RJ f S f Ll! 4S•J �:L f i�IE]i1�ft]�E]f/i]t]�lEl['7lY�lt�!!.� t3.7�lte7ia70�7[�i©��il�©��t3� t>otOtaOt>ODt>aSam=lltatif�ili�lE]t>E7if ��O�oOOO �000�00 13 OR SPACED AS Manufacturer: TABLE FF BELOW Cr, o Ci N 0�,1.1., lA�mericlVa 111 6360 TOPAZ COURT �I2 FORT MYERS, FL 33912 Tel,: (239) 278-3066 Fox: (239) 278-5977 r16 Product: Croci Extruded Aluminum Accordion Shutte: W �Il 1 1 N �YII N W a Engineering: pa +Fn�C�n Jztr. 3 CA 8116 6971 W. Sunrise Blvd. 104 Plantation, FI. 33313 I5 Tel.: (954) 585-0304 IS 9 --�tE1REpp'•,�1 )`) �►-1.623 13 fir: 46 o,,'��• (ED) EDGE J, SO •f y DISTANCE 0. ANCHOR SPACED AS 1, �,�nn'�qq11 qgqr `�FedP� PER TABLE FF BELOW- 4niF pl LnW do � ` • •'PL`'92609 SECTION FF - MAXIMUM ANCHOR SPACING INCHES Orl CENTER Date: 11/15/06 BLADE SIZE (IN) — Scale: NA Design by: PPMF Revlslon: ��F:tw�liY��iI.•�■tL�ti�� �i�Jtt�! �[1�lfIE]!s]E]l�K]li]�B�-71�[ii7Jf 7 [i70i1�E7F��lilQ�lil�!!llijEElEi7 �• L���IE]f�lsf�a�t�.yt:>t�t7lC�t]El �olota�Q000���rar�o� ANCHOR DESCRIPTION EMBED. ManuFacturer Ede Dlst. 1 a con Into 171n. sl contra a /2 co a on Irt - 0 0l ow I c / ' I o A3 1/4Log Wood Screws Into wood (SG=,55) 1 3/4' Generic 1' 1/4-Eu Ca -In into min. 000 psi oncrete 7/8 Powers Drawing Number 06-342 Sheet 3 of 6 SECTION O C — INSET MOUNT ADJUSTABLE TRACK SILL APLLICATION ONLY W is �- 10 IS 13 ° k12X5/8' TEKS AT 6' oc ICA 1.133 1,692--I (ED) EDGE DISTANCE I SECTION GO - MAXIMUM ANCHOR SPACING INCHES ON CENTER _ AD__S E (IN) /:i�%1<l►::irl�ti�l(:i�I',>�r:�%>;:ri�b><icnriif:�lrr�a �ii0ata001a001�]00�1�]� Manufacturerl�T 7 Cr'oci North SECTION H SIDE CLOSURE America 6360 TOPAZ COURT 2' EDGE FORT MYERS, FL 33912 DISTANCE-'� ANCHORS TYPE To].; (239) 278-3066 Al, A2 OR A3 Fax: (239) 278-5977 SPACED AT 24'OC MIN..06' ALUM. ANGLE SIDE CLOSURE / 4' SDS OR Product: 3/l6POP RIVET 3/16' i,'rocl / SPACED AT 24' OC Extruded Aluminum Accordion Shutter SECTION J 90' CORNER 3 SECTION H' Engineering: ALTERNATE TEn.g&a Int. SIDE CLOSURE A° CA 8116 2 EDGE _„1 6971 W. Sunrise Slyd, 104 DISTANCE MIN..06' ALUM.Plantation, FI. 33313 ANGLE SIDE Tel.: (954) 585-0304 CLOSURE r`�VgIREpp`�,�1 ANCHORS TYPE ! y AL A2 OR A3 SPACED AT 24'OC 64 1 .-'j `+a S ` �Q 410x3/4' SDS OR 3/l6' POP RIVET IA LE SAME ALUM, ANGLE SAFIE ALUM. 3 -8 SPACED AT 24'OC � i ` I`�td��tl@,��' LENGTH AS BLADE i� 0I0x3/4' SDS OR Date: 11/15/06 3/16' POP RIVET SPACED AT 6'OC Scale: NA Design by: PPMF ' SECTION I Revislon: INSET CLOSURE I ANCHORS TYPE At, A2 OR A3 II !-SPACED AT 24'OC ANCHOR ESCRII?LION____ EMBED, ManuFacturerl Ede Dist, . >� t ".. - a corn-mrrf lrcancret!➢Y.T// a con n o w co 2 2' A3 1/4' La NoodScrewsinto wood CSG=.55) Generic I 1' 4- a -In I'n a nin. 2 00 psi Concre-e owere 3' Drawing Number 06-342 Sheet 4 of 6 SECTION L LOCK AND BLADE SECTION 1 6,- p1OTEi SHUTTER CAN BE LOCKED FROM INSIDE OR OUTSIDE BY PLACING LOCK o. NaW INSIDE OR OUTSIDE AS REQUIRED. view J¢y a�i maw �aN 1vW INTERIOR OR EXTERIOR SIDE FEMALE STACK ALTERNATE SECTION L LOCK BLADE WITH STARTER BLADE SECTION 7 KEY OR THUNBTURN LOCK LOCATED ON ACCORDION INTERIOR OR EXTERIOR SIDE MALE STACK 1 I SECTION H, I OR J I I I I I i Manufoclurer: Croci North America 6360 TOPAZ COURT FORT MYERS, FL 33912 Tel.: (239) 278-3066 Foz. (239) 278-5977 Product: Croci Extruded Aluminum Accordion Shutter Eng&a +lnr. CA 8116 6971 W. Sunrise Blvd. 104 Planlation, FI. 33313 Tel.: (954) 585-0304 ,11 Off 4L IQ D i t> fill', �I .. PidrQ, e j��t{reao' P 3i 09, Dale: 11/15/06 Scale: NA Design by: PPMF Revlslon: Drawing Number 06-342 Sheet 5 of 6 4 COMPONENTS 0.085 T- lV IL --{ 3.115 0.110 f=�` 0,250 1.031 1- 1" WALL MOUNT TRACK 0.095I1 4,115--� �0.250 it 1.000 N IIA- 2' WALL MOUNT TRACK 5415 Q.085 I ` I- �0.250 0'L110 3,115 0.110 L I 1.031 IB- 3" WALL MOUIU' TRACK 2- CEIUNO TRACK 6- MALE LOCK STYLE 2.256—-2.225--j N o (11 �_ 0062 7- FEMALE LOCK STYLE o N � W 0.062 4.579 { .039 -4039 0.062 0.4?7 I —, 052 1.636 --I' 3- BLADE 6- LOCK BLADE INSERT 10.71dO.D701 TIn II70 I T-ADJUSTABLE SILL TRACK 2,825 0.128 0.070 M 0.0851 1,OA- ADJUSTABLE SILL CHANNEL BILL OF MATERIALS ITEM I DESCRIPTION MATERIAL MANUFACTURER 1 1 V WALL MOUNT RACK 6063-T6 ALUMINUMROCI IA 2' WALL MOUNT TRACK 6063-T6 ALUMINUM CR CI 3' WALL MOUNT TRACK 6063-T6 ALUMINUM CROCI ' CEILING TRACK 6063-T6 ALUMINUM CROC 075 ACCORDION BLADE 6063-TS ALUMINUM CROCI Ltl K BLADEI ERT 6063-T6 AL MINUM CROCI MALE LOCK BLADE 6063-T6 ALUMINUM CROCI MALE LOCK BLADE 6063-TG AL MINUM CROCI e STARTER BLADE 6063-T6 ALUMINUM CROCI 9 RACK 6063-T6 A6UMINUMROCI 10 ADJUSTABLE TRACK 6063-T6 AL MINUM CROCI A ADJUST, CHANNEL 0 3- ALUMINUM C 11 12 WHrEL CARRIER PLATED L/ NYLON ROCI 13 4. 3' SCREW BLADE410 STAINLESS STEEL CROCI 1 SS L CROCI 15 l'x7/16' USHIN NYLON CROC 16 1/ 'x7/16' WHEEL BUSHING NYLON NOCI 17 1/8 BUILT -OUT ANGLES 6063-T6 ALUMINUM CROCI l8 1/4'-RX3 ANGLE 6063-T6 ALUMINUM CROC1 1 20 3/B'x 5461 WHEEL SPACER NYLON CROCI TYPICAL BUSHING ASSEMBLY 3 �--14 Ll5 � 13 TYPICAL WHEEL ASSEMBLY l4 to �20 L-13 [!'3 12 17- BUILT -OUT ANGLES 8- STARTER BLADES 0.498 •Ir--0.062 IS- MOUNT TYPE E ANGLE 4 N I I T ni I MIN, 0,498 y 0.062 0,250 f�►---3.000 I 0125 I I t 1.507 is 9- 'A' TRACK Manufacturer: Croci North America 6360 TOPAZ COURT FORT MYERS, FL 33912 Tel.: (239) 278-3066 Fax: (239) 278-5977 Product: Croci Extruded Aluminum Accordion Sh . nr CA 8116 6971 W. Sunrise Blvd. 104 Plantation, FI. 33313 Tel.: (954) 585-0304 �'AljryQer $oo� ; �+y 0.679Ar 0.183 _ — -2 I � ---3.246 Date: l i /15/06 Scale: NA Design by: PPMF Revfslon: Drawing Number 06-342 Sheet 6 of 6 r 3/B" MIN 0 �m N n -RF WELD (2) ADD'L STRIPS OF = FABRIC ENTIRE LENGTH OF EDGE STRIPS (TOP & BOT) -OPTIONAL q OVERLAP 3 AT PANEL M > MIDSPAN .+ O i 0.037" MIN PANEL THICKNESS OW) 1—T- r1/2" HOLE ,III. 1.050" FLANGE .m . TM 0.725' 0.373" 0.313" ' T� � MIN � 0.472" o 0 N 0.093"TYP k 0.657" l2.000° —t 0.093" TYP STUDDED TRACK MOUNT -60.0' PSF +62.0 PSF z ANGLE B 3 "F" ANGLE "HOLE 1 6" - V-0" 1 6" - 1'-0" o SPAN NOTES 3' 471" 0.373"MO.O93" 0.500" 0,313" 0.47V .�, 1.050" FLANGE 1, ALLOWABLE PRESSURES SHALL NOT BE EXCEEDED. 2. PANEL SPANS LONGER THAN MAXIMUM NOTED ABOVE ARE NOT ACCEPTABLE. 3. PANEL SPANS LESS THAN MINIMUM NOTED ABOVE ARE NOT ACCEPTABLE. , 4. NO SEPARA71ON FROM GLASS IS REQUIRED WHEN PANEL SPAN IS GREATER THAN MINIMUM SPAN NOTED ABOVE. ,µ 6 'tl' 4 GROMMET 5. VALID FOR PANELS MOUNTED VERTICALLY OR HORIZONTALLY. YP L 0 093" TYP ' 6"=r-D• IsoMETTucGENERAL NOTES; ..-: . r . 1 THIS STORM PANEL - -.. .; - T 4 "F" TRACK • . SYSTEM HAS... TESTED AND EVALUATED AS A LARGE MISSILE CT PROTECTIVE SYSTEM IN ACCORDANCE WITH THE 20D4 FLORIDA ILDING CODE s "BF"' TRACK IAMNoTHE 1 PANEL PROFILE ' 2003INTERNATIONAL BUILDING/RESIDENTIAL CODE, FOR USE ODUTSIDE 6.. " � � "' � �. 1 6". ='3'-0". ' � FLORIDA'S HIGH VELOCITY HURRICANE ZONE (HVHZ) ONLY. ' 1'-0". 1 6" = 1'-0". 1 2. THIS SHUTTER SYSTEM HAS BEEN SUBMITTED TO ICC-ES FOR EVALUATION AS A .. - LARGE MISSILE IMPACT PROTECTIVE SYSTEM. . .; 3, NO 33 -1/3^k INCREASE IN ALLOWABLE STRESS HAS BEEN USED IN THE DESIGN OF . WIDTH UNLMITED (NON -SPAN DIRECTION) .. THIS PRODUCT. WIND LOAD. DURATIO •N FACTOR Cd=1.6 HAS BEEN USED FOR WOOD ANCHOR'DESIGN. , 1 7/16° MIN -4. POSITIVE AND NEGATIVE DESIGN PRESSURES TO BE USED WITH THESE DRAWINGS ' 12" TYPICAL VERTICAL GROMMET SPACING MOUNTING (END GROMMET) SHALL BE DETERMINED BY OTHERS FOR SPECIFIC JOBS IN ACCORDANCE WITH THE GOVERNING CODE. WHEN CALCULATING PRESSURES PER ASCE 7-98 (OR LATER ED1Ti0N), , .- SECTIONS . ,USE OF DIRECTIONALITY FACTOR Kd-0.85 IS ALLOWED. ` =. 1 3/B° MIN ..S. THE SHUTTER SYSTEM DETAILED HEREIN IS GENERIC AND DOES NOT PROVIDE. O INFORMATION . TOP MOUNT (CONN TYPE AS,REQ'D) OPTIONAL SIDE FOR A SPECIFIC SITE. IF SITE CONDITIONS DEVIATE FROM HE (TYP ALL CONDITIONS DETAILED HEREIN, A LICENSED ENGINEER OR REGISTERED ARCHITECT SHALL - zo ,. ANCHORS (TYP GROMMETS) PREPARE SITE SPECIFIC DOCUMENTS TO BE USED IN COW UNCTION WITH THIS DOCUMENT ' 2 3/B" MIN C OPTIONAL 1 3/4° OVERLAP AT EITHER SIDE PERMIT.HOLDER FLAP (TOP •` LDER SHALL VERIFY THE ADEQUACY OF HE EXISTING STRUCTURE TO AT MID -SPAN (SEAM WELD OR BOTH SIDES) &BOTTOM) ,WITHSTAND. NEW SUPERIMPOSED LOADS.- - I zuL d ENTIRE OVERLAP LENGTH) A - ; , . 7 STORM PANELS SHALL BE PVC COATED WOVEN POLYESTER FABRIC (THICKNESS t=0.037") WITH A MIN. FU-15.794 ? " N O STORM PANEL SHALL BE KSI $ CORNER GROMMET .B. PANELS SHALL BE PERMANENTLY. LABELED WITH A MINIMUM OF ONE _LABEL PER PANEL AS FOLLOWS:. 6 '`°x INSTALLED WITHOUT EXCESSIVE SLACK, SUCH - 1 ' 3 1 0 ;; : WgYNE DALTON CORP •_ ce --_ -=THAT OPENINGS BETWEEN =======_ '. " , FLB DWG NO 04 WDF-0004 _ � j -•`. O 3 PANEL & HOST STRUCTURE . ' _ OPTIONAL SIDE' -'� REFERENCE FLORIDA STATEWIDE APPROVAL - " ' ANCHORS (ANY ANCHOR ' 9 DO NOT EXCEED 10% OF .STORM PANELS HAVE BEEN DESIGNED AND TESTED TO THE MAXIMUM SPAN AND STORM PANEL @ > - TOTAL COVERAGE AAEA • „ ,. FROM ANCHOR SCHED) .; LOADS SHOWN ON THESE DRAWINGS. REFERENCE HURRICANE ENGINEERING &TESTING HORIZ SECTION '' ` W1TH RF-WELDED 3-PLY .- INC HETI,OF,MTAMI, FL .TEST REPORTS.Nos. HETI-04-1907, HEII-04-1390 HETI-03-1873 (THIS PAGE) N0 SIDE '. RF WELD (1) 4"x3" ) FABRIC REINF FABRIC & #4 GROMMET H -03-1875� HETI-03-1885a, 'HETI-03 1885h, & HETI-04-T224., '' •; I g m _'ANCHORS,2-PLY _ SHOWN:. TO FABRIC PANEL AT�T•— ': i0 PANELS MAY: BE h10UNTED MORIZONTALI.Y WHERE -APPLICABLE (I.e WITHliNE OF - HIS SIDE ; EACH SIDE ANCHOR. ANCHORAGE IN VERTICALDIRECTION) >' t.,' PANELS .MAYBE INSTALLED WITH. OPTIONAL SIDE ANCHORS AS DEPICTED HEREIN ' HOWEVER SYSTEM PERFORMANCE IS BASED ON TESTING WITHOUT SIDE ANCHORS.' TESTS I "ter .. .�• - SHOW A FAILURE LOAD OF.987 LBS FOR;HE,#4,GROMMET AND 4"x3" 3-PLY RF-..WELDED' 1 EXISTING HOST.'`. FABRIC CONSTRUCTION AT EACH SIDE ANCHOR (ANCHOR NOT.CONSIDERED).`".`'' BOTTOM MOUNT '• 12 ALL 12" TYPICAL y„- - ', STRUCTURE_ 0.40.,MAX BOLTS &WASHERS SHALL BE ZINC COATED;'GALVANIZED OR STAINLESS SjEEL '.. .•, (CONN TYPE AS REQ D) .. -GROMMET - W 13 TAU: ACCEPTANCEI CRITERIA LE STRENGTH SPACING -' x AT SIDESOF 0 '- � -- •! AVE BEEN MET FOR THIS SHUTTER AS A NON -POROUS ... V T TYPICAL: VERTICAL MOUNT,;: .;� - '� .T SYSTEM, -AS DEFINED.IN ASTM E3996 TIN KEEPING WITH.THIS STANDARD, NO MINIMUM ','-,HORIZQNTAL SECTION "-; -'SEPARATIONFROM,TF{EGLAZINGBEING.PROTECTED;ISREQUIRED - ANDBAEpISINGOFHIS ' GLAZINGDOESNOT COMPROMISETHEBUILDING ENVELOPE N.T.S. .,.. ..1 .,. ' HORIZ SECTION _ _ 1 r T. 5 -f r L'4 BUILDING `CODE COMPLIANT,. ,?2004 FLORIDA. . 04,;/�007 LL 0Z WNm a It FT® #m u. L11 rWrn u1,-' j % U R LLZW Z a —� 8 >� W a�LL c� W Z m W° °w �93 w q NK� p w ,o w •• CL AY Z Ow,E Q 8 id -B �Zrl'm � lu �hmla � NN r T iI EXISTING HOST EXTERIOR WALL FINISH EXISTING HOST STRUCTURE 7 (TYP ALL VERT SECTIONS) STRUCTURE CONN TYPE C2: CONN TYPE C2: ANCHOR PER ANCHOR PER ANCHOR SCHED '4 ,ANCHOR SCHED 1/2" MAX , EMBED 1/4-20 x 3/4" wr /2 1/4-20 X 3/4" STUDS AT 12° O.C.. wFF STUDS AT C3 MAX o:! 12" O.C. W/ wo WITH WASHEED w0 W.W.N. WINGNUT "W.W.N." fl I (PART #306B98) r1 NO MIN. _I 1,:: I � � NO MIN._I a.+ EXISTING REQ'D -' J-}— SEPAR w 1 . w EXISTING E D -+= GLAZING zd. y GLAZING a ul o. u_ Yt3VH �� d5 W.W.N. OR 1/4°xl/2" 5.5. �� 1/4-ZO x 3/4" '- SIDEWALK BOLTU�• STUDS AT STR8 p (PART #306900) 12" O.C. W/ MOMWa.TY. P.E�CI'''�Q_ W.W.N. —}-—L-�=f- ANCHOR SHOWN IN ANCHOR SCHED 1� MOU TINE SECTION . 2 3" = V-0" VERT SECTION MAY EXISTING HOST STRUCTURE ANCHOR SCHED ANCHOR SCHED 2 MOUNTING SECTION -.. 2 3" = V-0" VERT SECTION EXTERIOR WALL' FINISH (TYP ALL CONN TYPE Cl: DIECT MOUNT W/ ANY ANCHOR SHOWN IN .' VERT. BECKONS), ANCHOR SCHEDULE.(INCL. NON -REMOVABLE) EXISTING HOST STRUCTURE °STORM PANEL DECORATIVE STORAGE` (SPDS) 2-PIECE COVER, MOUNTED WITH SAME ANCHORS USED FOR STORM PANEL ANCHOR SCHEDULE 1 7 o x ANCHOR LOAD (psf) 3/4" MIN EDGE DISTANCE UNLESS OTHERWISE NOTED Spans Up To W-0:' CONN TYPE C3 C2C3 Spans Up To 6'-0' CONN TYPE C3 C2 C3 Spans Up To 9'-3" CONN'TYPE Cl I C2 I C3 1/4"LAG SCREW WITH MIN 2-3/32" THREAD PENETRN. THREAD �PENETR� 30 12" 12" 1 5" 11" 11" 1 4" 7" 7" 38 12" 12" W- 8" 1 8" 3" S" 5" 47 10" 10" 1 3" 7" 7" 4" 4" 54 9" 9" 3" 6" 6" 4""4" fifi 7" 7" 5" 5" 3" 3" 1/4" TAPCON (ELCO OR ITW) OR #14 WOOD SCREW WITH 1-1/2' MIN EMBED 30 12" 12" 6" 11" 11" 4" 7" 7" 3" 38 12" 12" 5" 9" 9" 3" 6" 6" 47 10" 10" 4" 7" 7" 3" 4" 4" 54 9" 9" 3" 6" 6" 4" 4" fifi 7" T' 3" 5" 5" elZZ 3" 3" 1/4' ITW TAPCON SG WITH 1-1/2" MIN EMBED �C 30 12" 12" 12" 12" 12" 12" 12" 12" 12" 12" 12" 12" 12" 12" 12" 11" W12" 12" 12" 12" 12" li" 11" 7" 12" 12" IV' 11" 9" 9" 6" 12" 12" 12" 9" B" 8" 4" N a O, 3/16° ITW SAMMY SUPER SCREW WITH 1-1/T MIN EMBED .. * 30 12" 12' 12" 12" 12" 12" 12" 12" I 38 12" 12" 12" 12" 12" 12" 12" L2" 10" 47 12" 12" 12" 12" 12" 12" 12" 12" 7" 54 12" 12" 12" 12" 12" 10" 10" 1W 6" fifi 12" 12" 12" 12" 12" 8" 9" 9" 4" O,PANEIMAi'E••(¢91i'F ORit MALE)�,WITF11�7/B° M(N - _ .•-.. 30 12 12. 12' L 12" 12. 12" 12" t3B1 In% AV 12' tit' 12" 12" 12" 10" W47I i•2 2 12 12" 12" ISZ 12" IV' AVU 12' B" 12" 2" 12" 11" 12" 12" 6" -fifi 12" IV- 12" 12" 12" 9" 10" 10" 5" .{�%49'HANGER BOLT (MALE) W/ 2 1/2' MIN EMBED & 1 1/4" E.D. ;. ;}EMBEDt 30 12" 12" 5" 11" 11" 4" 7" 7" 38 12" 12" 4" 8" 8" 3" S" S" 47 10" 30" 3" 7" 7" 4" 4" •54 9" 9" 3"' 6" 6" 4" 4" fifi 7" 7" 5" 5" 3" 3° ' 5/16" HANGER BOLT (MALE) W/ 2 1/2' MIN, EMBED & 1 1/4 E.D. ; , = `.•. }EMBED t 30 12" 12' 12" 12" 12" 12" 12" 12" 12" 38 12" 12" 12" 12" 12" 12" 12" 12" 12" '47 12" 12" 12" 12" 12" 12" 12" 12" 9" 54 12" 12" 12" 12" 12" 12" 12" 12" 7" fifi 12" 12" IV- 12" 12" 10" 11" 11" 6" 3/8' HANGER BOLT (MALE) W 3" MIN. EMBED & 1, 1/2" E, D., }EMBED * 30 12" 12" 12" 12" 12" 12" 12" 12" 12" 38 12" 12" 12" 12" 12" 12" 12" 12" 12" 47 12" 12" 12" 12' 12" 12" 12" IV' 10" 54 12" 12" 12" 12" 12" 12" 12" 12"' 7" .fifi 12" 12" 12" 12" 12" 12" 11" 11" 6" 2 5 NO MIN. SEPAR.,ANCHOR RCQ'D 1/4-20 3/4" ,,, 2d NOTES:...:.. - - y° TING x -+ STUDS AT 12" w = G B ' <' `_ z�;i 1) 1/4" TAPCONS SHALL BE BY ITW OR BY ELCO, AS LISTED INAPPROPRIATE ANCHOR SCHEDULE. "ELCO "iZING O.C. W/ W.W.N. pm„W O v, f:: G=7 PANELMATE" ANCHORS MAYBE MALE OR FEMALE ONLY, AS ILLUSTRATED. 2) ENSURE MINIMUM EDGE DISTANCE FOR ALL ANCHORS - PER RESPECTIVE ANCHOR SCHEDULE.. EDGE DISTANCE OF 3/4' IS ACCEPTABLE FOR ANCHORS TO WOOD, EXCEPT FOR 5/16" AND 3/8" g STORM PANEL, 'a ANGER BOLTS, REFERENCE ANCHOR SCHEDULE FOR MINIMUM EDGE DISTANCE EQUIEMENTS FOR THESE ANCHORS. ' ROLLED UP& . '3) MINIMUM EMBEDMENT SHALL BE AS NOTED IN ANCHOR SCHEDULE. MINIMUM EMBEDMENT AND . p NO MIN ; STORED.INSIDE EDGE DISTANCE EXCLUDES STUCCO, FOAM, BRICK, AND OTHER.WALL FINISHES. - • , 'EXISTING SEPAR. EQ'D .SPDS° WHEN I 4)) ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTUERS RECOMMENDATIONS. -5) •. LEG DIR• 8 E• Q '• CONN TYPE C3: GLAZING NOT IN USE :. ,: WHERE EXISTING STRUCTURE IS WOOD FRAMING EXISTING CONDITIONS MAY VARY.FIELD,. . VERIFY THAT ANCHORS ARE INTO. ADEQUATE WOOD FRAMING MEMBERS NOTINTOPLYWOOD.':`r";5.•:�::;-''-<• '•. MAYBE m� REVERSED w EDGE ANCHOR PER ANCHOR SCHED � '� :,, : �6) ANCHORS FASTENED TO NARROW FACE OF, STUD FRAMING BE LOCATED IN CENTER OF DI .' STORM PANEL IN "PLACE NOMINAL' M (MIN) WOOD STUD (I.e.3/4 EDGE DISTANCE IS ACCEPTABLE FOR ANCHORS TO WOOD WHEN IN USE FRAMING.). WOOD STRUCTURE SHALL BE SOUTHERN PINE".,GAO 55 SPRUCE-PINEFIR G 0 42, OR .; -. EXISTING HOSTSTRUCTUE ,. :..GREATER 4- ANCHORSCHE6t::::_:�� ;..,, ,:.: •... ..:+. {�`:"'.�* - . • + . PRO HEREIN, BUT ONLY PROVIDES MAXIMUM >,"SPDS",SECTION' RSPACINGLLMAXIMUMSALL01(JABLESPANS AND PRESSUESINDICATED MOUNTING SECTION (OPTIONAL) '� SCHEDULE ,'. ' ''ei HALLLAVEMINIMUM y' - - _ ,:;`.;:. MACHINE SCREWPAN S OF ENGA+GE S MENITOFTHREADSINBASEANCHOR �l 2 3 1-0" VERTSECTION., - 2 3 1 0 VERT SECIION `' HEAD '(.°SIDEWALK BOLT°)-U,N.O. - 9j DESIGNATES ANCHOR CONDITIONS WHICH ARE NOT ACCEPTABLE FOR USE CH AN ORS. LE AND MA B USED. FOR E � bI MO � Y WHICH ARE.REMOVABLE ECiJ. _ .. .... t � '.i. : tr INS7ALLATION35IGNATES ; .. { E " y` '' S> > . .:. ., :, ..;. , . ,;.,; , .•', , �- ..' .. � 04F/60 7 IJ LL to n 0 o (rjn] # a- m i 1WWED JAu I I' aZW W=..X� W /L/L/L������n111 U LL w ww z = f0 W o 1/IW�i in 3 0 w w•• ANCHOR SCHEDULE 2 ANCHOR SCHEDULE 3 04FL0007 w I r 3 E ANCHOR SCHEDULE, 4 o x ANCHOR LOAD (psf) 2" MIN EDGE DISTANCE 2-1/2" MIN EDGE DISTANCE Spans Up To 4'-0" CONN TYPE C1 C2 C3 Spans Up To 6'-0" CONN TYPE C1 C2 C3 Spans Up To 9'-3" CONN TYPE C1 C2 C3 Spans Up To 4'-0' CONN TYPE C1 C2 C3 Spans Up To 6'4 CONN TYPE C1 C2 I C3 Spans Up To 9'-3" CONN TYPE C1 I C2 I C3 1/4" TAPCON (ELCO) WITH 1-1/4" EMBED 30 12" 12" 12" 12" 12"J14V 12" 12" 6" 12" 12" 12" 12" 12" 12" 12" 12" 8" 38 12" 12" 12"-1Z' 12"12" IT' 5" 12" 12" 12" 12" 12" 10" 12" 12" 6" 47 12" 12" 9" 12" 12"10" 10" 4" 12" 12" 12" 12" IT' B" 12" 12" 5" 54 12" 12" 8" 12" 12" 8" 8" 3" 12" 12" 10" 12" 12" 7" SO" 10" 4" 66 12" 12" 7" 10" 10" 7" 7" 3" 12" 12" 8" 12" 12"6" 9" 9" 3" 1/4" TAPCON (IIW) WITH 1-1/4" EMBED 30 12" 12" 6" 11" 11" 7" 7" 3" 12" 12" 7" 12" 12" 5" 9" 9" 3" 38 12" 12" 5" 8" 8" 5"' 5" 12" 12" 6" IV 11" 4" 7" 7" 47 10" 10" 4" 7" 7"4" 4" 12" 12" 5" 9" 9" 3" 6" 6" 54 9" 9" 3" 6" 6"4" 4" 11" 11" 4" 7" 7" 3" 5" 5" 66 7" 7" 3" 5" V.3" 3" 9" 9" 3" 6" 6" 2" 4" 4" 1/4" ELCO PANEL14ATE (MALE OR FEMALE) WITH MIN 1-1/4" EMBEDMENT * 30 12" IT' 12" 12" 12" 9" 11" 11" 6" 12" 12" 12" IT' IT' 10" 12" IT' 6" 38 12" 12" 11" 12" 12" 7" 9" 9" 5" 12" 12" 11" 12" 12", 8" 10" 10" 5" 47 12" 12" 9" 11" 11" 6" 7" 7" 4" 12" 12" 9" 12" IT' 6" 8" 8" 4" 54 12" 12" B" 10" 10" 5" 6" 6" 3" 12" 12" 8" It" 411, 5" 7" 7" 3" 66 12" 12" 6" 8" B" 4" 5" 5" 12" 12" 7" 9" 4" 6" 6" 3" 1/4" ITW TAPCON SG OR SAMMY SUPER SCREW WITH MIN 1 1/4" EMBED * 30 12" 12" 12" 12" 12" 12" 12" 12" 8" 12" 12" 11" 12" 12" 7" 12" IT, 5" 38 12" IT' 12" 12" 12" 9" 11" 11" 6" 12" 12" 9" 12" 12" 6" 9" 9" 4" 47 12" 12".11" 12" 12" B" 9" 9" 5" 12" 12" T' 12" 12" 5" all B" 3" 54 12" 12" L 12" 12" 7" 8" 8" 4" 12" lY' 6" 10" 10' 4" 7" 7" 3" 66 12" 12" 10" 5" 7" 7" 3" IV 12" 5" 8" 8" 3" 6" 6" 2" ' 1/4-20 ALL POINTS SOLID -SET ANCHOR WITH MIN 7/8" EMBEDMENT * q, 30 12" 12" 12" 12" 12" 12" SF 12" 8" 12" 12" 12" 12" 12" 12" 12" IT, 9" 38 12" 12" 12" 12" 12". 10" 12" 12" 1 6" 12" 12" 12" 12" 1Y' 11" 12" IT' 7" 47 12" 12" 11TJ 12" 12" 8" 10" 10" 5" 1 12" 12" 12" 12" 12" 9" 12" 12" 5" •54 IT' 12" 10" 12" 12" 7" 9" 9" 4" 1 12" 12" 11" 12" 1XI 7" 11" 11" 4" 66 12" IZ' 8" 11" 11" 6" 8" 8" 3" 12" IV 9" 12" 12" 6" 9" 9" 4" g 1/4-20 POWERS CALK -IN WITH MIN 7/8" .'. EMBEDMENT' : * 30 12" 12" 9" 12" 12" 6" 9" 9" 4" 12" 12" 11" 12" 12" 7" 12" Ir 5" 738 12" 12" 7" 11" It" I 5" 7" 7" 3" 12" 12" 9" 12" IT' 6" 9" 9" 4" 47 12" IT' 1 6" 9" 9" 1 4" 6" 6" 3" 12" IT' 7" 12" 12" 5" a" 8" 3" 54 12" 12" S" 8" B" 4" 5" 5" 12" 12" 6" 10" 10" 41- T' 7" 3" 66 10" 10" V' 6" 6" ITF, 4" 4" 12" 12" 5" 8" 8" 3" 6" 6" 2" ._ 5/16"TAPCON (ELCO) WITH MIN .1.1/4". EMBED ,. 30 IT' 12" 12" 12" IZ' 10" IT' 12" 7" -38 12" 12" 12" 12" 12" 8" 12" 12" 5" ..47 12" IT' 10" 12" IT' 6" 10" 10" 4" -54 12" IT' 8" 12" 12" 6" 9" 9" 66 12" 12" 7" 11" 11" 5" 8" B" 3/8" RED HEAD LOT W/ MIN ''': 30 12" 12" 12" 12" 12" 9" 12" "38 12" 12" 10" 12" 12" 7" 12"47 Y2 12" 8" 12" 12" 6" 11" JIT-6"11/4-EMBEDMENT .s4 12" 12" 7" 12" IT' 5" 10" 12,IT' 6" 12" 12" 4" B" 3 1/2MIN EDGE DISTANCE '. 4-1/2" MIN EDGE DLSTANCE : ••. Spans Up To Spans Up To Spans Up To Spans Up To Spans Up To Spans Up To LOAD ' •: 4._0" •6,_0.. `.9'_3" .....4'-0'..:' 6,_0' ,. ,. 9,_3., :. . (psf) CONN TYPE CONN TYPE CONN TYPE CONN TYPE CONN TYPE CONN TYPE Cl 1621 C3 •Cl C21 6 '61 I C21 C3 Cl C2 C3 Cl I C2 '6 Cl C2 C3 5/16" TAPCON (ELCO) WITH MIN 11/4 EMBED ;30 12" 12" 12" IT' IX' 11" 12" 12" 7" V 38 12" IT' 12" 12" IT' 8" 12" 12" 5" 47 12" lY' T07, 12" 12" T, 11" 11" 4" .'54 12" IT' 9" 12" 12" 6" 10" 10" 66 12" IT' 7" IT' IT' S" V 9" 3/8" RED HEAD.LDT W/ MIN 1 1/4" EMBEDMENT _ . :..66 30 12" IT' IT' 12" IT' 9" 12" IT' 6" 3B 12" 12" 11" 12" IT' 7" 12" 12" 5" .'47 12" 12". 9" IT' 12" 6" IT' 12" .'54' 12" 12" 7'!- IT' 12" 5" 10" 10" 12" 12" 6"• 12" 12" .9'!..g" ;- ' 318-16 POWERS,CALK IN �.. W/ MIN,11/4 EMBEDMENT -�:30 12" 12" IT' IT' 12" IT' 12" 12" 1 9" 1 12' "3B 12" 12" 12" IT' 12" 11" 12" IT! 7" 12" 12" 12" 12" 12" 12,47 12" 12" 12!' 12" IT' 12" 9", 12" IT' 5" 12" 12" 12" 12" 12" 10' 12" 12" 11" 12" 12" 7" 12" IV S" 12" IT' 12" 12" 1Y' 9".. IT' 12" 9" 12" 12". 6" 10" 10" 4" 1.12 12 11 12" IT' 7„ 04FL0007 • U O bNgmg F¢cn r®^ m MWu, W-10-. 13z >u u�g Qg- 0 : q�T W" 2 W rm < o .Ni 3. J W m 0tu k