HomeMy WebLinkAboutSUBMITTED PAPERSDate: Fee Due: Recei t# Permit #
St. Lucie County Building & Zoning
2300 Virginia Avenue Ft. Pierce, FL 34982-5652
Tel. •462-1553
SPECIALTY PERMIT APPLICATION 3 Co4h�y
❑ Electrical ❑ Plumbing M HVAC ElFence
❑ Shed ❑ Demolition ❑ Gas ❑ Siding
See page'2 for instructions and additional paperwork required for specialty permits
1. Location/Site Address: CAM �!/�� ✓ �_ / / ��
2. Parcel ID Number:
Office Use
Only%
Section
Township
Range
Map Page
Zoning
Land Use
I Initials
3. Description of Project or Fork
/ (�_� � J /1-7 /
/ / -
4. Owners� IA_ or ati l
Name: i;.�-?'_r(��`"�
5. Contractors Information
_ FL Reg/Cert #: r
Address: 7''� County C,ert#:
City: State:
Business Name:
Zip: %� Phone r
l� Phone Z Fax 22-
T�
.
) Cei� PA ors c .37 G�_ `
6. 3,5-o O2
Value of Construction: $
OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done
in compliance with all applicable laws regulating construction and zoning.
PRINT,QUALIFIERS/OWNERS NAME
STATE OF FLORIDA, COUNTY OF
;SIGNATURE OF QUALIFIER/O R
`._'•;ACKNOWLEDGED
BEFORE ME THIS DAY OF
20& BY J .L
fl
WHb'15 PERSONALLY KNOWN TOME OR WHO HAS PRODUCED
ASr FNNTIFICATION fi
, ,, , Q r'
T1• d."�cyw
• - fit/ �✓
(. � I"7 �/ (seal)
SIGNATURE OF NOTARY
. TYPE OR PRINT NAM5 F.NO_TARY
• TITLE: NOTARY PUBLIC
COMMISSION Nl1MBElt`._�°''
`' GLORIA
++"""�' BRADSHAW-
Public - State of Florida '
St. Lucie County Specialty Permit Application rev. 8/25/05 dmg
,Notary
'• .. ' My Comm. Expires Sep 10. 2012
';,tj "' Commission # DD 821474
Bonded Through National Notary Assn.
I
NOTICE TO OWNER: •FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR
LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
EXEMPT: A/C -HEAT REPLACEMENT WITH CONTRACT UNDER $5,000.
INSTRUCTIONS
Please complete all information in the space provided. All information must be printed (use black or blue ink
only) or typed. This permit application is to be used only for those activities that are not otherwise included
under a primary building permit. This application may not be used for any activity that includes structural
alteration. The information to be provided with this application includes:
1. Location/Site Address
2. Parcel ID Number
3. Description of Project or Work Activity
4. Owner Information
5. Contractor Information
6. Value of Construction
Indicate the street address or,general location of the
property where the building activity is taking place.
Indicate the tax identification number of the,property
where the building activity is taking place.
Fully describe the activity to take place.
Indicate the name and address of the owner of the property
on which activity is taking place.
Indicate the State of Florida registration number (if
applicable), St. Lucie County contractor license number
and the name of the business doing the work.
Indicate the total value of the work to take place. Total cost
of construction includes all current retail material and labor
costs associated with the building/construction activity.
Construction value is used to determine the permit fee. St.
Lucie County reserves the right to question and/or modify
the indicated value of construction if it is demonstrated that
the submitted figures are not consistent with -similar types
of construction.
❑ Gas Attach 2 piping schematics with tank size, location, and BTU of each appliance
❑ Shed: Attach 2 plot plans, 2 copies of DCA letter and plans, 2 anchor specifications
❑ Fence Attach 2 plot plans showing location of fence height of fence and type of fence
❑ Siding Attach 2 copies of manufactures specifications
❑ HVAC Attach 2 residential energy studies, 2 manual J calculations. 2 sets of duct layouts for
new system or full replacement
This application can be submitted to St. Lucie County Building and Zoning, 2300 Virginia Avenue, Fort
Pierce, FL 34982. All permit applications must be .filled out completely before submission. No applications
will be accepted for processing after 4:30 P.M. For assistance in completing this application, please call
(772) 462-1553, during regular office hours (8:00 AM -- 5:00 PM), Monday through Friday,
NOTE: Emergency electric service change out inspections will not he performed after 3: 00 PM without
special arrangements and adEionireV;.1S/Z5/D53IrU&i,1T
edba d
Upon issuance ofthis permit,'A eYiti by calling (772) 462-1261.
(Ia W ilainii7�nito� s a t"St. Lucie County Specialty Permit Applbeiaa8
Code Compliance Division
2300 Virginia Avenue
Ft. Pierce, FL 34982
Phone: (772) 462-1553 Fax: (772) 462-1578
http://www.stiucieco-org/public—works/pormifting.htm
Date: 10 December 2008
Job Address: 104 CAMELOT DR
Received By: humphreya
Paid With: CK
Building
Receipt
Receipt #:
0000066818
'ermit Number:
SLC- 0812-0135
Amount:
$50.00
�redit Card Number:
Check Number:
2170
Paid By: V. A. C. REFRIGERATION & AIR CONDITIOP Sign:
a
Wednesday, Dec 10, 2008 02:50 PM
R'EDMAR0 r�QFg_;TRIIt_ I_'li'i
1?1gg?•?0t�8 '�3.1,4_ . 8775<46257; .
Au;. 4. 2009 > ' 50PM ST. _U(" 1 E C011M T V' P!JR..CFA„ i'N,;
�-- t Fort #16m, ev fL 3,4982
THESE PLANS AND ALL PROPOSED WORK f!!mo F W (712) 46441
99
ARE SUBJECT TO ANY CORRECTIONS�������
REQUIRED BY FIELD INSPECTORS THAT
emAY BE NEECEoftY MSeSLALRe®
Y IN
(N� OR�D�]E�'ERTOOC
104 CatMIOt Dr.
Fart Pierce, FL
016
ST. LUCIE COUNTY
BUILDING DIYWIVON'
REVI
--- —ff _aoiA.
DATE
FOLANIVAND PERMIT
MUST BEf KEPT ON JO® OR
NO INSPECTION WILL BE MADE
mal
'%a()PY
PO-0111t, 0 1
v
FORM 60OA-2004R
EnergyGauge® >?=
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION 0
Florida Department of Community Affairs
Residential Whole Building Performance Method A
Project Name: 104 Camelot Builder:
Address: Permitting Office:
City, State: Permit Number:
Owner: Jurisdiction Number:
Climate Zone: Central
New construction or existing New —
12. Cooling systems
Cap: 30.2 kBtu/hr
Single family or multi -family Single family —
F4.
a. Central Unit
—
SEER: 13.00
Number of units, if multi -family 1 —
Number of Bedrooms 3 —
b. N/A
—
5. Is this a worst case? No —
—
6. Conditioned floor area (ft') 1362 ft' —
c. N/A
—
7. Glass type I and area: (Label reqd. by 13-104.4.5 if not default)
—
a. U-factor: Description Area
(or Single or Double DEFAULT) 7a(Sngle Default) 140.0 112 —
13. Heating systems
a. Electric Heat Pump
Cap: 21.0 kBtu/hr —
HSPF: 8.50
b. SHGC:
—
(or Clear or Tint DEFAULT) 7b. (Tint) 140.0 ft2 —
b. N/A
—
8. Floor types
—
a. Slab -On -Grade Edge Insulation R=0.0, 272.0(p) ft —
c. N/A
—
b. N/A —
—
c. N/A —
14. Hot water systems
9. Wall types
a. Electric Resistance
Cap: 40.0 gallons —
a. Concrete, Int Insul, Exterior R=4.0, 1362.0 ft' —
EF: 0.97 —
b. N/A —
b. N/A
—
c. N/A —
d. N/A —
c. Conservation credits
—
—
e. N/A —
(HR-Heat recovery, Solar
10. Ceiling types _ —
DHP-Dedicated heat pump)
a. Under Attic R=30.0, 1362.0 ft'
15. HVAC credits
—
b. N/A —
(CF-Ceiling fan, CV -Cross ventilation,
c. N/A —
HF-Whole house fan,
11. Ducts —
PT -Programmable Thermostat,
a. Sup: Con. Ret: Con. AH(Sealed):Interior Sup. R=6.0, 200.0 ft
MZ-C-Multizone cooling,
b. N/A —
MZ-H-Multizone heating)
Glass/Floor Area: 0.10 Total as -built points: 15144 PASS
Total base points: 17448
I hereby certify that the plans and specifications covered by
this calculation are in complia with the Florida Energy
Code.
PREPARED Y: ml
DATE: O
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGENT: VA' aje-.� ,
DATE: 12- /0 - Os?
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
BUILDING OFFICIAL:
DATE:
1 Predominant glass type. For actual glass type and areas, see Summer 8 Winter Glass output on pages 284.
EnergyGauge® (Version: FLRCSB v4.5.2)
}
FORM 60OA-2004R EnergyGauge® 4.5.2
Code Compliance Checklist
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT #:
6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST
COMPONENTS
SECTION
REQUIREMENTS FOR EACH PRACTICE
CHECK
Exterior Windows & Doors
606.1.ABC.1.1
Maximum:.3 cfm/s .ft. window area; .5 cfm/s .fL door area.
Exterior & Adjacent Walls
606.1.ABC.1.2.1
Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall;
foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility
penetrations; between wall panels & top/bottom plates; between walls and floor.
EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends
from and is sealed to, the foundation to the top plate.
Floors
606.1.ABC.1.2.2
Penetrations/openings >118" sealed unless backed by truss or joint members.
EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed
to the perimeter, penetrations and seams.
Ceilings
606.1.ABC.1.2.3
Between walls & ceilings; penetrations of ceiling plane of top floor, around shafts, chases,
soffits, chimneys, cabinets sealed to continuous air barrier, gaps in gyp board & top plate;
attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is
installed that is sealed at the perimeter, at penetrations and seams.
Recessed Lighting Fixtures
606.1.ABC.1.2.4
Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a
sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from
conditioned space, tested.
Multi -story Houses
606.1.ABC.1.2.5
Air barrier on perimeter of floor cavity between floors.
Additional Infiltration reqts
606.1.ABC.1.3
Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA,
have combustion air.
6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.)
COMPONENTS
SECTION
REQUIREMENTS
CHECK
Water Heaters
612.1
Comply'with efficiency tequirements in Table 612.1.ABC.3.2. Switch or clearly marked cr
breaker electric or cutoff as must be provided. External or built-in heat trap required.
Swimming Pools & Spas
612.1
Spas & heated pools must have covers (except solar heated). Non-commercial pools
must have a pump timer. Gas spa & pool heaters must have a minimum thermal
efficiency of 78%.
Shower heads
612.1
Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG.
Air Distribution Systems
610.1
All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically
attached, sealed, insulated, and installed in accordance with the criteria of Section 610.
Ducts in unconditioned attics: R-6 min. insulation.
HVAC Controls
607.1
Separate readily accessible manual or automatic thermostat for each system.
Insulation
604.1, 602.1
Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides.
Common ceiling & floors R-11.
FILE COPY
EnergyGaugeTM DCA Form 60OA-2004R EnergyGaugeO/FlaRES'2004R FLRCSB v4.5.2
FORM 60OA-2004R EnergyGauge@ 4.5.2
WATER HEATING & CODE COMPLIANCE STATUS
Residential Whole Building Performance Method A - Details
I ADDRESS: , , , PERMIT #: I
BASE
AS -BUILT
WATER HEATING
Number of X Multiplier
= Total
Tank EF
Number of X Tank X Multiplier X Credit = Total
Bedrooms
Volume
Bedrooms Ratio Multiplier
3 2460.00
7380.0
40.0 0.97
3 1.00 2333.20 1.00 6999.6
As -Built Total:
6999.6
CODE
COMPLIANCE STATUS
BASE
AS -BUILT
Cooling + Heating +
Points Points
Hot Water
Points
= Total
Points
Cooling + Heating + Hot Water = Total
Points Points Points Points
7279 2789
7380
17448
5000 3144 7000 16144
EFP:ASS
FILE COPY
EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge@1FIaRES'2004R FLRCSB v4.6.2
�1
FORM 60OA-2004R EnergyGauge® 4.5.2
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
I ADDRESS: , . , PERMIT #:
BASE
AS -BUILT
Winter Base Points:
5034.6
Winter As -Built Points:
7723.1
Total Winter X System =
Heating
Total X Cap
X Duct X System X
Credit =
Heating
Points Multiplier
Points
Component Ratio
Multiplier Multiplier
Multiplier
Points
(System - Points)
(DM x DSM x AHU)
(sys 1: Electric Heat Pump 21000 btuh ,EFF(8.6) Ducts:Con(S),Con(R),Int(AH),R6.0
7723.1 1.000
(1.000 x 1.160 x 0.87) 0.402
1.000
3144.0
5034.6 0.5640
2789.1
7723.1 1.00
1.014 0.402
1.000
31 ".0
FILL: COPY
EnergyGaugeTM DCA Form 60OA-2004R EnergyGauge®/FIaRES'2004R FLRCSB v4.5.2
1
FORM 60OA-2004R EnergyGauge® 4.5.2
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT M
BASE
AS -BUILT
GLASS TYPES
.18 X Conditioned X BWPM =
Points
Overhang
Floor Area
Type/SC
Omt
Len
Hgt
Area X WPM X WOF = Point
.18 1362.0
9.11
2233.0
1.Singie, Tint
W
2.0
4.0
8.0
13.80 1.04
115.0
2.Single, Tint
S
2.0
5.0
12.0
10.88 1.18
154.0
3.Single, Tint
N
2.0
5.0
9.0
15.38 0.99
137.0
4.Single, Tint
S
2.0
6.0
24.0
10.88 1.12
291.0
5.Single, Tint
N
2.0
5.0
18.0
15.38 0.99
275.0
6.Single, Tint
N
2.0
4.0
12.0
15.38 0.99
183.0
7.Single, Tint
N
2.0
4.0
6.0
15.38 0.99
91.0
8.Single, Tint
E
2.0
5.0
9.0
13.04 .1.04
122.0
Mingle, Tint
S
2.0
6.0
24.0
10.88 1.12
291.0
10.Single, Tint
E
2.0
4.0
6.0
13.04 1.06
82.0
11.Single, Tint
S
2.0
6.0
12.0
10.88 1.12
145.0
As -Built Total:
140.0
1886.0
WALL TYPES
Area X
BWPM
= Points
Type
R-Value
Area X
WPM =
Points
Adjacent
0.0
0.00
0.0
1. Concrete, Int Insul, Exterior
4.0
1362.0
3.35
4562.7
Exterior
1362.0
2.00
2724.0
l
Base Total:
1362.0
2724.0
As -Built Total:
1362.0
4562.7
DOOR TYPES
Area X
BWPM
= Points
Type
Area X
WPM =
Points
Adjacent
0.0
0.00
0.0
1.Exterior Insulated
20.4
5.10
104.0
Exterior
20.4
5.10
104.0
Base Total:
20.4
104.0
As -Built Total:
20.4
104.0
CEILING TYPES Area X
BWPM
= Points
Type
R-Value
Area X WPM X WCM =
Points
Under Attic
1362.0
0.64
871.7
1. Under Attic
30.0
1362.0 0.64 X 1.00
871.7
Base Total:
1362.0
871.7
As -Built Total:
1362.0
871.7
FLOOR TYPES
Area X
BWPM
= Points
Type
R Value
Area X
WPM =
Points
Slab
272.0(p)
-1.9
-516.8
1. Slab -On -Grade Edge Insulation
0.0 272.0(p
2.50
680.0
Raised
0.0
0.00
0.0
Base Total:
-516.6
As -Built Total:
272.0
680.0
INFILTRATION
Area X BWPM
= Points
Area X
WPM =
Points
1362.0
-0.28
-381.4
1362.0
-0.28
-381.4
EnergyGauge® DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004R FLRCSB v4.5.2 FILE COPY
FORM 60OA-2004R
EnergyGauge® 4.5.2
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
I ADDRESS: , , , PERMIT #: I
BASE
AS -BUILT
Summer Base Points: 22397.4
Summer As -Built Points:
19558.8
Total Summer X System = Cooling
Total X Cap
X Duct X System X
Credit =
Cooling
Points Multiplier Points
Component Ratio
Multiplier Multiplier
Multiplier
Points
(System - Points)
(DM x DSM x AHU)
(sys 1: Central Unit 30200btuh ,SEER/EFF(13.0) Ducts:Con(S),Con(R),Int(AH),R6.0(INS)
1
22397.4 0.3250 7279.2
19559 1.00
19568.8 1.00
0.00 x 1.150 x 0.85) 0.260
0.983 0.260
1.000
1.000
5000.1
5000.1
k
EnergyGaugeTM DCA Form 60OA-2004R EnergyGauge@/FIaRES'2004R FLRCSB v4.5.2 FILE COPY
FORM 60OA-2004R EnergyGauge® 4.5.2
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , , ,
PERMIT #:
BASE
AS -BUILT
GLASS TYPES
.18 X Conditioned X BSPM =
Floor Area
Points
Type/SC
Overhang
Omt Len Hgt Area X
SPM X
SOF = Points
.18 1362.0
24.35
6970.0
1.Single, Tint
2.Single, Tint
Mingle, Tint
4.Single, Tint
5.Single, Tint
6.Single, Tint
7.Single, Tint
8.Single, Tint
9.Single, Tint
10.Single, Tint
11.Single, Tint
W
S
N
S
N
N
N
E
S
E
S
2.0 4.0 8.0
2.0 5.0 12.0
2.0 5.0 9.0
2.0 6.0 24.0
2.0 5.0 18.0
2.0 4.0 12.0
2.0 4.0 6.0
2.0 5.0 9.0
2.0 6.0 24.0
2.0 4.0 6.0
2.0 6.0 12.0
47.90
39.84
24.46
39.84
24.46
24.46
24.46
53.27
39.84
53.27
39.84
0.74
0.75
0.88
0.80
0.88
0.84
0.84
0.81
0.80
0.74
0.80
283.0
359.0
192.0
762.0
386.0
245.0
122.0
386.0
762.0
235.0
381.0
As -Built Total:
140.0
4112.0
WALL TYPES
Area X
BSPM
= Points
Type
R-Value Area
X SPM
=
Points
Adjacent
Exterior
0.0
1362.0
0.00
1.90
0.0
2587.8
1. Concrete, Int Insul, Exterior
4.0 1362.0
1.20
1634.4
i
Total:
1362.0
2587.8
As -Built Total:
1362.0
1634.4
[Base
DOOR TYPES
Area X
BSPM
= Points
Type
Area
X SPM
=
Points
Adjacent
Exterior
0.0
20.4
0.00
4.80
0.0
97.9
1.Exterior Insulated
20.4
4.80
97.9
20.4
97.9
As -Built Total:
20.4
97.9
rBaseTotal:
YPES
Area X
BSPM
= Points
Type
R-Value Area X SPMXSCM=
Points
1362.0
2.13
2901.1
1. Under Attic
30.0 1362.0 2.13 X 1.00
2901.1
se Total:
1362.0
2901.1
As -Built Total:
1362.0
2901.1
OOR TYPES
r
Area X
BSPM
= Points
Type
RValue Area
X SPM
=
Points
b 272.0(p)
0.0
-31.8
0.00
-8649.6
0.0
1. Slab -On -Grade Edge Insulation
0.0 272.0(p
-31.90
-8676.8sed
Base Total:
-8649.6
As -Built Total:
272.0
-867g.8
INFILTRATION_
Area X BSPM = Points
Area X SPM
=
Points
1362.0
14.31
19490.2
362
14. 1
19490.2
EnergyGauge® DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004R FLRCSB v4.5.2 rILI: t;Upy
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE SCORE* = 88.6
The higher the score, the more efficient the home.
1. New construction or existing New _
12. Cooling systems
2. Single family or multi -family Single family _
a. Central Unit
Cap: 30.2 kBtu/hr
3. Number of units, if multi -family l _
SEER: 13.00 _
4. Number of Bedrooms 3 _
b. N/A
5. Is this a worst case? No
_
6. Conditioned floor area (ftz) 1362 ft' _
c. N/A
7. Glass type and area: (Label reqd. by 13-104.4.5 if not default)
_
a. U-factor: Description Area
13. Heating systems
_
(or Single or Double DEFAULT) 7a(Sngle Default) 140.0 ft2 _
a. Electric Heat Pump
Cap: 21.0 kBtu/hr _
b. SHGC:
HSPF: 8.50 _
(or Clear or Tint DEFAULT) 7b. (Tint) 140.0 W _
b. N/A
_
8. Floor types
a. Slab -On -Grade Edge Insulation R=0.0, 272.0(p) ft _
c. N/A
_
b. N/A
_
c. N/A _
14. Hot water systems
9. Wall types
a. Electric Resistance
Cap: 40.0 gallons
a. Concrete, Int Insul, Exterior R=4.0, 1362.0 ftz _
EF: 0.97 _
b. N/A _
b. N/A
c. N/A
_
d. N/A _
c. Conservation credits
_
e. N/A _
(HR-Heat recovery, Solar
10. Ceiling types
DHP-Dedicated heat pump)
a. Under Attic R=30.0, 1362.0 ft- _
15. HVAC credits
b. N/A _
(CF-Ceiling fan, CV -Cross ventilation,
_
c. N/A _
HF-Whole house fan,
11. Ducts
PT -Programmable Thermostat,
a. Sup: Con. Ret: Con. AH(Sealed):Interior Sup. R=6.0, 200.0 ft _
MZ-C-Multizone cooling,
b. N/A _
MZ-H-Multizone heating)
I certify that this home has complied with the Florida Energy Efficiency Code For Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant fe s. o
Builder Signature: Date: ! 2 -��-
Address of New Home: /0���` City/FL Zip: ( tC
*NOTE: The home's estimated energyperformance score is only available through the FLA
This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPA/DOE EnergyStar"" designation),
your home may qualifyfor energy efficiency mortgage (EEM incentives ifyou obtain a Florida Energy Gauge Rating.
Contact the Energy Gauge Hotline at 3211638-1492 or see the Energy Gauge web site at www.fsec. ucf edu for
information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building
Construction, contact the Department of Community Affairs at 8501487-1824.
1 Predominant glass type. For actual glass type and areas, see Summer & Winter Glass output on ages 2&4.
EnergyGauge® (Version: FLPRCS> v4.5.2)
Rhyac�.-,Residentiaf.&-Ught Commercial HVAC �qac Elite Software Development, Inc.
'
N
S6tAhetn, nt Camelot
erpn§e§, 04
FortOiiarct FC34946 Page 8
Project title:
104 Camelot
Designed by:
Tammy
Project date:
Tuesday, December 09,2008
Project comment:
Client name:
Client address*.
Client city:
Client phone:
Client fax:
Client comment:
Company name:
Southern Enterprises
Company representative:
Tammy
Company address:
4994 Deann Ln
Company city:
Ft Pierce Fl 34946
Company phone-
772-519-0019
Company fax.
772-4612775
Company comment:
HzVAC, Equip-m- p-nt,
Aem: -SystOn 1
Air Handier Name =I
Cooling Description
—
Air Source Heat Pump
Cooling Model Type
Cooling Model Number
UPNE-030J*Z+UHSA-HM3017+RCSA-H*3617A*
Cooling Capacity
30,200 Btuh
Cooling Efficiency
13 SEER
Heating Description
Air Source Heat Pump
Heating Model Type
Heating Model Number
Heatifid.. Capacity
47°F: 33,400 / 17°F: 21,000 Btuh
Heating Efficiency
8.5 HSPF
FILE COPY
Rlivac Residential Light Commercial HVAC Loads Elrte Software Development, Inc.:
So` fern Enterprises 104 Camelot
Fort Pierce, FL 3494E , : Page 7`
SyStem 1 Room Load Summary
---Zone 1---
1
Utility
110
2,463
32
2
Family Room
168
14,282
186
3
Kitchen
100
1,671
22
4
Bath 1
19
385
5
5
Master Bedroom
182
2,187
28
6
Dining
154
2,123
28
7
Bath 2
40
878
11
8
Bedroom 1
143
2,811
37
9
Living Room
182
2,296
30
10
Bedroom 2
143
2,992
39
11
Wic
121
564
7
1-6
474
2,046
52
93
93
3-6
478
6,189
308
282
282
1-7
532
3,123
22
142
142
1-4
13
25 _
0
1
1
1-5
618
1,853
432
84
84
1-4
642
1,232
35
56
56
1-4
299
573
12
26
26
1-6
550
2,375
452
108
108
1-5
477
1,431
35
65
65
1-6
539
2,327
455
106
106
1-4
81
155
0
7
7
System 1 total 1,362 32,652 424 21,329 1,803 970 970
System 1 Main Trunk Size: 1205 in.
Velocity: 776 ft./min
Loss per 100 ft.: 0.093 in.wg
Cooling S stani Summary
Net Required: 1.93 92% / 8% 21,329 1,803 23,132
Recommended: 2.37 75% 125% 21,329 7,110 28,439
Actual: 2.52 75% / 25% 22,650 7,550 30,200
Eq'uj irient•Data;�- ° -
Heating System Cooling System
Type: Air Source Heat Pump Air Source Heat Pump
Model:
Indoor Model:
Brand:
Description:
Efficiency:
Sound:
Capacity:
Sensible Capacity:
Latent Capacity.
ARI Reference No.:
Ruud UPNE Series
Air Source Heat Pump
8.5 HSPF
47°F: 33,400 / 17°F: 21,000 Btuh
n/a
n1a
n/a
Ruud UPNE Series
Air Source Heat Pump
13 SEER
30,200 Btuh
22,650 Btuh
7,550 Stuh
703070
FILE COPY
Rhvac -Residential & Ligllt Commercial HUAC Loads
Elite Software Development, Inc
Southern Enterpnses`
104Cameiot=
Fort Pierce; FL 34946--
System 1; Zone 1 Summary Loads (Average Load Procedure for Roofs)
Area
Sen L.a't
°.' Seri Totef..
I'Coinponerit
Descripton, _ LL . Quart ,
Loss.. . Gain
' -- Gain Gain ;
1A-cb-o: Glazing -Single pane, operable window, clear, 140
4,536 0
5,776 5,776
metal frame with break, u-value 1.08, SHGC 0.75
11 N: Door -Metal - Polystyrene Core 20.4
214 0
186 186
13AB-0ocb: Wall -Block, no blanket or board insulation, 1783.6
14,554 0
8,441 8,441
open core, brick finish
16C-30: Roof/CeilingzUnder Attic with Insulation on Attic 1194.2
1,146 0
1,529 1,529
Floor (also use for Knee Walls and Partition Ceilings),
Vented Attic, No Radiant Barrier, White or Light Color
Shingles, Any Wood Shake, Light Metal, Tar and
Gravel or Membrane, R-30 insulation
16A-30: Roof/Ceiling-Under Attic with Insulation on Attic 168
161 0
376 376
Floor (also use for Knee Walls and Partition Ceilings),
Unvented Attic, No Radiant Barrier, Any Roofing
Material, Any Roof Color, R-30 insulation
22A-ph: Floor -Slab on grade, No edge insulation, no 272
11,083 0
0 0
insulation below floor, any floor cover, passive, heavy
moist soil
Subtotals for structure:
31,694 0
16,308 16,308
People: 6
1,200
1,380 2,580
Equipment:
0
3,400 3,400
Lighting: 0
0 0
Ductwork:
0 0
0 0
Infiltration: Winter CFM: 29, Summer CFM: 15
958 603
241 844
System 1, Zone 1 Load Totals:
32,652 1,803
21,329 23,132
j Check Fi aces
Supply CFM: 970 CFM Per Square ft.:
0.712
Square ft. of Room Area: 1,362 Square ft. Per Ton:
575
Volume (" of Cond. Space: 10,898
Total Heating Required: 32,652 Btuh
32.652 MBH
Total Sensible Gain: 21,329 Btuh
92 %
Total Latent Gain: 1,803 Btuh
8 %
Total Cooling Required: 23,132 Btuh
1.93 Tons (Based On Sensible + Latent)
2.37 Tons (Based On 75% Sensible
Capacity)
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
i
Rhvac Residential Light Commetcial HVAC Loads Elite Software Development, Inc:
Southern Enterpnses ' 104 Camelot
Fort Pierce FL 34946°. Page 5'
System 1 Summary Loads
Component =
Area Sen
Lat �;
Sen
Total
Dasri lion : 'L3uarr
Loss
Gain i, -Gain
Gain
1A-cb-o: Glazing -Single pane, operable window, clear,
140
4,536
0
5,776
5,776
metal frame with break, u-value 1.08, SHGC 0.75
11 N: Door -Metal - Polystyrene Core
20.4
214
0
186
186
13AB-0ocb: Wall -Block, no blanket or board insulation,
1783.6
14,554
0
8,441
8,441
open core, brick finish
16C-30: Roof/Ceiling-Under Attic with Insulation on Attic
1194.2
1,146
0
1,529
1,529
Floor (also use for Knee Walls and Partition Ceilings),
Vented Attic, No Radiant Barrier, White or Light Color
Shingles, Any Wood Shake, Light Metal, Tar and
Gravel or Membrane, R-30 rrrsuiadon
16A-30: Roof/Ceiling-Under Attic with Insulation on Attic
168
161
0
376
376
Floor (also use for Knee Walls and Partition Ceilings),
Unvented Attic, No Radiant Barrier, Any Roofing
Material, Any Roof Color, R-30 insulation
22A-ph: Floor -Slab on grade, No edge insulation, no
272
11,083
0
0
0
insulation below floor, any floor cover, passive, heavy
moist soil
Subtotals for structure:
31,694
0
16,308
16,308
People:
6
1,200
1,380
2,580
Equipment:
0
3,400
3,400
Lighting:
0
0
0
Ductwork:
0
0
0
0
Infiltration: Winter CFM: 29, Summer CFM: 15
958
603
241
844
Ventilation: Winter CFM: 0, Summer CFM: 0
0
0
0
0
System 1 Load Totals:
32,652
1,803
21,329
23,132
.Check�Fj ores `-
Supply CFM: 970
CFM Per Square ft.:
0.712
Square ft. of Room Area: 1,362
Square ft. Per Ton:
575
Volume (ft?) of Cond. Space: 10,898
S :stem",Loads
Total Heating Required Including Ventilation Air:
32,652
Btuh 32.652
MBH
Total Sensible Gain:
21,329
Btuh 92
%
Total Latent Gain:
1,803
Btuh 8
%
Total Cooling Required Including Ventilation Air:
23,132
Btuh 1.93
Tons (Based On Sensible + Latent)
2.37
Tons (Based On 75% Sensible
Capacity)
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
FILE COPY
-Sduthern EnWrphses.,
Elite Software Development, lnc:
,F
Pierce'Fort L
404-Cam-610
__P
-.34946,.
aEle-4
Total Building Summary Loads
Compo-nent'- Area
Quan.,
Sen
Loss
Latt Sera-
Gain Gain
'Total',
Gain
1 A-cb-o: Glazing -Single pane, operable window, clear,
I _ 40
4,536
0
5,776
5,776
metal frame with break, u-value 1.08, SHGC 0.75
11 N: Door -Metal - Polystyrene Core
20.4
214
0
186
186
13AB-Oocb: Wall -Block, no blanket or board insulation,
1783.6
14,554
0
8,441
8,441
open core, brick finish
16C-30: Roof/Ceiling-Under Attic with Insulation on Attic
1194.2
1,146
0
1,529
1,529
Floor (also use for Knee Walls and Partition Ceilings),
Vented Attic, No Radiant Barrier, White or Light Color
Shingles, Any Wood Shake, Light Metal, Tar and
Gravel or Membrane, R-30 Insulation
16A-30: Roof/Ceiling-Under Attic with Insulation on Attic
168
161
0
376
376
Floor (also use for Knee Walls and Partition Ceilings),
Unvented Attic, No Radiant Barrier, Any Roofing
Material, Any Roof Color, R-30 insulation
22A-ph: Floor -Slab on grade, No edge insulation, no
272
11,083
0
0
0
insulation below floor, any floor cover, passive, heavy
moist soil
Subtotals for structure:
31,694
0
16,308
16,308
People:
6
1,200
1,380
2,580
Equipment:
0
3,400
3,400
Lighting:
0
0
0
Ductwork:
0
0
0
0
Infiltration: Winter CFM: 29, Summer CFM: 15
958
603
241
844
Ventilation: ,..Winter .-CFM: .O.,-Summer CFM: .O
0
0
0
0
Total Building Load Totals:
32,652
1,803
21,329
23,132
7,
Total Building Supply CFM: 970 CFM Per Square ft.: 0.712
Square ft. of Room Area: 1,362 Square ft. Per Ton: 575
Volume (11P) of Cond. Space: 10,898
Total Heating Required Including Ventilation Air: 32,652
Btuh
32.652
MBH
Total Sensible Gain: 21,329
Btuh
92
%
Total Latent Gain: 1,803
Btuh
8
%
Total Cooling Required Including Ventilation Air: 23,132
Btuh
1.93
Tons (Based On Sensible + Latent)
2.37
Tons (Based On 75% Sensible
Capacity)
Notes
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
FILE COPY
Rhv,,. -,R!esid!ential.&'Light.CbmMetclai,Hy4q,-',�.Qadt Elitejnc.r
Ic'.
Sbbth epj .,erpnse.,,-'I Q*Ca6@6t
F60, Pierce FL,14946Pa
[Load Preview Report
1 ! l
Has; NetNet'Recl ft.11, 6en LatSys
' ! sysNet; Sew Sys; Duct
Scope AED!� Ton' Ton' fToni Area Gain' Gain GainHfgClg!
Loss' Act(SizeCM CFM' CFMI
...............
Building 1.93� 2.37: 575, 11,362� 21,329� 1,803' 23,132� 32,652: 424: 970, 970
. ...... ....... .......... 1. w- I 1 -1-1 * I - -- I -**-*-, - — - 1— - -1 - . .. ...
System I Yes. 1.93. 2.37,; 575" 1,362: 21,329 1,801" 23,113232,652: 424,9 i- ---970. -14.1.5.
Zone I 1 3 6 2' 21 3 2 9; 1,803 23,132 32,652 424 l 970' 12x1 5
1-Utility 1102,046_ 522,098 2,463'. 32 II 93* 1-6
2-Family Room 168: 6,189: 308: 6,497, 14,282: 1860 282 3-6
3-Kitchen 1001 3,123, 22 3,145 1,671. 22 142: 1-7
4-Bath 1 19: 25 0 25: 385: 5 1 1-4
--------- --- 5-Master Bedroom 182: 1,853' 432' 2,285: 2,187: 28 84 1-5
6-Dining 1541 Y232, 35, 1,26T 2,123� 28 56: 1-4
........... . .....
7-Bath 2 40573: 12: 585: V& 11.M 26: 1-4
8-Bedroom 1 143: 2,375: 452: 2,827: 2,811- 37. 108: 1-6
9-Living Room
....... 182� .65. 1-5
10-Bedroom 2 143. 2,327. 455' 2,782 2,992; 39'M ... 106'.- 1-6
11 -Vvic 121 155. 0 155: 564� 7 1 7 1-4
FILE COPY
va
Rhc Residential &Light Commercial HVAC Loads
Elite Software Development, Inc.
Southern Enterpnses
104 Camelot.
Fort-P-.i6r FL 34946'
Pa eZ°
Miscellaneous Report
[System 1:.' Gutdoar,,
u
:Outdoors Ind£10f IndOUF °Grains°
!r� 'utData.. ° .:D Bzrlb}/t $utb ,R61 t-#urn . ;: ;D.. 8u16... Difference'
Winter: 42
0 30 72 3.44
Summer: 90
78 50 75 61.09
Dud Sizirt` Irtpur5 -
Main Trunk
Runouts
Calculate: Yes
Yes
Use Schedule: Yes
Yes
Roughness Factor: 0.00300
0.01000
Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft.
Minimum Velocity: 650 ft./min
450 ft./min
Maximum Velocity: 900 ft./min
750 ft./min
Minimum Height: 0 in.
0 in.
Maximum Height: 0 in.
0 in.
nutside'Air Data .,
- .
Winter
Summer
Infiltration: 0.160
AC/hr 0.080 AC/hr
Above Grade Volume: X 10,898
Cu.ft. X 10,898 Cu.ft.
1,744
Cu.ft./hr 872 Cu.ft./hr
X 0.0167
X 0.0167
Total Building Infiltration: 29
CFM 15 CFM
Total Building Ventilation: 0
CFM 0 CFM
---System 1—
Infiltration & Ventilation Sensible Gain Multiplier:
16.49 = (1.10 X 0.999 X 15.00 Summer Temp. Difference)
Infiltration & Ventilation Latent Gain Multiplier:
41.50 = (0.68 X 0.999 X 61.09 Grains Difference)
Infiltration & Ventilation Sensible Loss Multiplier:
32.97 = (1.10 X 0.999 X 30.00 Winter Temp. Difference)
Rhvac - Residential & •Light;Commeteial HVAC: Loads ,-
Southern Enterprises;
Elite Software Development, Inc.'
- " 104'Cam elof
FortPierce`Fl .84946age
Project Report
General�Psoject;lnforrriation °- -�' '
'" -
Project Title: 104 Camelot
Designed By: Tammy
Project Date: Tuesday, December 09, 2008
Company Name: Southern Enterprises
Company Representative: Tammy
Company Address: 4994 Deann Ln
Company City: Ft Pierce FI 34946
Company Phone: 772-519-0019
Company Fax: 772-461-2775
.Desr n=Data771
Reference City: Fort Pierce, Florida
Daily Temperature Range: Medium
Latitude: 27 Degrees
Elevation: 25 ft.
Altitude Factor: 0.999
Elevation Sensible Adj. Factor: 1.000
Elevation Total Adj. Factor: 1.000
Elevation Heating Adj. Factor: 1.000
Elevation Heating Adj. Factor: 1.000
Outdoor Outdoor Indoor
Indoor Grains
Dry Bulb Wet Bulb Rel.Hum
Dry Bulb Difference
Winter: 42 0 30
72 3
Summer: 90 78 50
75 61
,Check Figures :.. -
Total Building Supply CFM: 970
CFM Per Square ft.: 0.712
Square ft. of Room Area: 1,362
Square ft. Per Ton: 575
Volume (ft3) of Cond. Space: 10,898
Buildin Loads , -
..
Total Heating Required Including Ventilation Air: 32,652
Btuh 32.652 MBH
Total Sensible Gain: 21,329
Btuh 92 %
Total Latent Gain: 1,803
Btuh 8 %
Total Cooling Required Including Ventilation Air: 23,132
Btuh 1.93 Tons (Based On Sensible + Latent)
2.37 Tons (Based On 75% Sensible
Capacity)
Notes :.:
-
Calculations are based on Bth edition of ACCA Manual S.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.