Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSDate: Fee Due: Recei t# Permit # St. Lucie County Building & Zoning 2300 Virginia Avenue Ft. Pierce, FL 34982-5652 Tel. •462-1553 SPECIALTY PERMIT APPLICATION 3 Co4h�y ❑ Electrical ❑ Plumbing M HVAC ElFence ❑ Shed ❑ Demolition ❑ Gas ❑ Siding See page'2 for instructions and additional paperwork required for specialty permits 1. Location/Site Address: CAM �!/�� ✓ �_ / / �� 2. Parcel ID Number: Office Use Only% Section Township Range Map Page Zoning Land Use I Initials 3. Description of Project or Fork / (�_� � J /1-7 / / / - 4. Owners� IA_ or ati l Name: i;.�-?'_r(��`"� 5. Contractors Information _ FL Reg/Cert #: r Address: 7''� County C,ert#: City: State: Business Name: Zip: %� Phone r l� Phone Z Fax 22- T� . ) Cei� PA ors c .37 G�_ ` 6. 3,5-o O2 Value of Construction: $ OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in compliance with all applicable laws regulating construction and zoning. PRINT,QUALIFIERS/OWNERS NAME STATE OF FLORIDA, COUNTY OF ;SIGNATURE OF QUALIFIER/O R `._'•;ACKNOWLEDGED BEFORE ME THIS DAY OF 20& BY J .L fl WHb'15 PERSONALLY KNOWN TOME OR WHO HAS PRODUCED ASr FNNTIFICATION fi , ,, , Q r' T1• d."�cyw • - fit/ �✓ (. � I"7 �/ (seal) SIGNATURE OF NOTARY . TYPE OR PRINT NAM5 F.NO_TARY • TITLE: NOTARY PUBLIC COMMISSION Nl1MBElt`._�°'' `' GLORIA ++"""�' BRADSHAW- Public - State of Florida ' St. Lucie County Specialty Permit Application rev. 8/25/05 dmg ,Notary '• .. ' My Comm. Expires Sep 10. 2012 ';,tj "' Commission # DD 821474 Bonded Through National Notary Assn. I NOTICE TO OWNER: •FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. EXEMPT: A/C -HEAT REPLACEMENT WITH CONTRACT UNDER $5,000. INSTRUCTIONS Please complete all information in the space provided. All information must be printed (use black or blue ink only) or typed. This permit application is to be used only for those activities that are not otherwise included under a primary building permit. This application may not be used for any activity that includes structural alteration. The information to be provided with this application includes: 1. Location/Site Address 2. Parcel ID Number 3. Description of Project or Work Activity 4. Owner Information 5. Contractor Information 6. Value of Construction Indicate the street address or,general location of the property where the building activity is taking place. Indicate the tax identification number of the,property where the building activity is taking place. Fully describe the activity to take place. Indicate the name and address of the owner of the property on which activity is taking place. Indicate the State of Florida registration number (if applicable), St. Lucie County contractor license number and the name of the business doing the work. Indicate the total value of the work to take place. Total cost of construction includes all current retail material and labor costs associated with the building/construction activity. Construction value is used to determine the permit fee. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with -similar types of construction. ❑ Gas Attach 2 piping schematics with tank size, location, and BTU of each appliance ❑ Shed: Attach 2 plot plans, 2 copies of DCA letter and plans, 2 anchor specifications ❑ Fence Attach 2 plot plans showing location of fence height of fence and type of fence ❑ Siding Attach 2 copies of manufactures specifications ❑ HVAC Attach 2 residential energy studies, 2 manual J calculations. 2 sets of duct layouts for new system or full replacement This application can be submitted to St. Lucie County Building and Zoning, 2300 Virginia Avenue, Fort Pierce, FL 34982. All permit applications must be .filled out completely before submission. No applications will be accepted for processing after 4:30 P.M. For assistance in completing this application, please call (772) 462-1553, during regular office hours (8:00 AM -- 5:00 PM), Monday through Friday, NOTE: Emergency electric service change out inspections will not he performed after 3: 00 PM without special arrangements and adEionireV;.1S/Z5/D53IrU&i,1T edba d Upon issuance ofthis permit,'A eYiti by calling (772) 462-1261. (Ia W ilainii7�nito� s a t"St. Lucie County Specialty Permit Applbeiaa8 Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 http://www.stiucieco-org/public—works/pormifting.htm Date: 10 December 2008 Job Address: 104 CAMELOT DR Received By: humphreya Paid With: CK Building Receipt Receipt #: 0000066818 'ermit Number: SLC- 0812-0135 Amount: $50.00 �redit Card Number: Check Number: 2170 Paid By: V. A. C. REFRIGERATION & AIR CONDITIOP Sign: a Wednesday, Dec 10, 2008 02:50 PM R'EDMAR0 r�QFg_;TRIIt_ I_'li'i 1?1gg?•?0t�8 '�3.1,4_ . 8775<46257; . Au;. 4. 2009 > ' 50PM ST. _U(" 1 E C011M T V' P!JR..CFA„ i'N,; �-- t Fort #16m, ev fL 3,4982 THESE PLANS AND ALL PROPOSED WORK f!!mo F W (712) 46441 99 ARE SUBJECT TO ANY CORRECTIONS������� REQUIRED BY FIELD INSPECTORS THAT emAY BE NEECEoftY MSeSLALRe® Y IN (N� OR�D�]E�'ERTOOC 104 CatMIOt Dr. Fart Pierce, FL 016 ST. LUCIE COUNTY BUILDING DIYWIVON' REVI --- —ff _aoiA. DATE FOLANIVAND PERMIT MUST BEf KEPT ON JO® OR NO INSPECTION WILL BE MADE mal '%a()PY PO-0111t, 0 1 v FORM 60OA-2004R EnergyGauge® >?= FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION 0 Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: 104 Camelot Builder: Address: Permitting Office: City, State: Permit Number: Owner: Jurisdiction Number: Climate Zone: Central New construction or existing New — 12. Cooling systems Cap: 30.2 kBtu/hr Single family or multi -family Single family — F4. a. Central Unit — SEER: 13.00 Number of units, if multi -family 1 — Number of Bedrooms 3 — b. N/A — 5. Is this a worst case? No — — 6. Conditioned floor area (ft') 1362 ft' — c. N/A — 7. Glass type I and area: (Label reqd. by 13-104.4.5 if not default) — a. U-factor: Description Area (or Single or Double DEFAULT) 7a(Sngle Default) 140.0 112 — 13. Heating systems a. Electric Heat Pump Cap: 21.0 kBtu/hr — HSPF: 8.50 b. SHGC: — (or Clear or Tint DEFAULT) 7b. (Tint) 140.0 ft2 — b. N/A — 8. Floor types — a. Slab -On -Grade Edge Insulation R=0.0, 272.0(p) ft — c. N/A — b. N/A — — c. N/A — 14. Hot water systems 9. Wall types a. Electric Resistance Cap: 40.0 gallons — a. Concrete, Int Insul, Exterior R=4.0, 1362.0 ft' — EF: 0.97 — b. N/A — b. N/A — c. N/A — d. N/A — c. Conservation credits — — e. N/A — (HR-Heat recovery, Solar 10. Ceiling types _ — DHP-Dedicated heat pump) a. Under Attic R=30.0, 1362.0 ft' 15. HVAC credits — b. N/A — (CF-Ceiling fan, CV -Cross ventilation, c. N/A — HF-Whole house fan, 11. Ducts — PT -Programmable Thermostat, a. Sup: Con. Ret: Con. AH(Sealed):Interior Sup. R=6.0, 200.0 ft MZ-C-Multizone cooling, b. N/A — MZ-H-Multizone heating) Glass/Floor Area: 0.10 Total as -built points: 15144 PASS Total base points: 17448 I hereby certify that the plans and specifications covered by this calculation are in complia with the Florida Energy Code. PREPARED Y: ml DATE: O I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: VA' aje-.� , DATE: 12- /0 - Os? Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: 1 Predominant glass type. For actual glass type and areas, see Summer 8 Winter Glass output on pages 284. EnergyGauge® (Version: FLRCSB v4.5.2) } FORM 60OA-2004R EnergyGauge® 4.5.2 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT #: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/s .ft. window area; .5 cfm/s .fL door area. Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from and is sealed to, the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings >118" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor, around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier, gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from conditioned space, tested. Multi -story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. 6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply'with efficiency tequirements in Table 612.1.ABC.3.2. Switch or clearly marked cr breaker electric or cutoff as must be provided. External or built-in heat trap required. Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1, 602.1 Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. FILE COPY EnergyGaugeTM DCA Form 60OA-2004R EnergyGaugeO/FlaRES'2004R FLRCSB v4.5.2 FORM 60OA-2004R EnergyGauge@ 4.5.2 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details I ADDRESS: , , , PERMIT #: I BASE AS -BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 3 2460.00 7380.0 40.0 0.97 3 1.00 2333.20 1.00 6999.6 As -Built Total: 6999.6 CODE COMPLIANCE STATUS BASE AS -BUILT Cooling + Heating + Points Points Hot Water Points = Total Points Cooling + Heating + Hot Water = Total Points Points Points Points 7279 2789 7380 17448 5000 3144 7000 16144 EFP:ASS FILE COPY EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge@1FIaRES'2004R FLRCSB v4.6.2 �1 FORM 60OA-2004R EnergyGauge® 4.5.2 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details I ADDRESS: , . , PERMIT #: BASE AS -BUILT Winter Base Points: 5034.6 Winter As -Built Points: 7723.1 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1: Electric Heat Pump 21000 btuh ,EFF(8.6) Ducts:Con(S),Con(R),Int(AH),R6.0 7723.1 1.000 (1.000 x 1.160 x 0.87) 0.402 1.000 3144.0 5034.6 0.5640 2789.1 7723.1 1.00 1.014 0.402 1.000 31 ".0 FILL: COPY EnergyGaugeTM DCA Form 60OA-2004R EnergyGauge®/FIaRES'2004R FLRCSB v4.5.2 1 FORM 60OA-2004R EnergyGauge® 4.5.2 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT M BASE AS -BUILT GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Omt Len Hgt Area X WPM X WOF = Point .18 1362.0 9.11 2233.0 1.Singie, Tint W 2.0 4.0 8.0 13.80 1.04 115.0 2.Single, Tint S 2.0 5.0 12.0 10.88 1.18 154.0 3.Single, Tint N 2.0 5.0 9.0 15.38 0.99 137.0 4.Single, Tint S 2.0 6.0 24.0 10.88 1.12 291.0 5.Single, Tint N 2.0 5.0 18.0 15.38 0.99 275.0 6.Single, Tint N 2.0 4.0 12.0 15.38 0.99 183.0 7.Single, Tint N 2.0 4.0 6.0 15.38 0.99 91.0 8.Single, Tint E 2.0 5.0 9.0 13.04 .1.04 122.0 Mingle, Tint S 2.0 6.0 24.0 10.88 1.12 291.0 10.Single, Tint E 2.0 4.0 6.0 13.04 1.06 82.0 11.Single, Tint S 2.0 6.0 12.0 10.88 1.12 145.0 As -Built Total: 140.0 1886.0 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adjacent 0.0 0.00 0.0 1. Concrete, Int Insul, Exterior 4.0 1362.0 3.35 4562.7 Exterior 1362.0 2.00 2724.0 l Base Total: 1362.0 2724.0 As -Built Total: 1362.0 4562.7 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 0.0 0.00 0.0 1.Exterior Insulated 20.4 5.10 104.0 Exterior 20.4 5.10 104.0 Base Total: 20.4 104.0 As -Built Total: 20.4 104.0 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points Under Attic 1362.0 0.64 871.7 1. Under Attic 30.0 1362.0 0.64 X 1.00 871.7 Base Total: 1362.0 871.7 As -Built Total: 1362.0 871.7 FLOOR TYPES Area X BWPM = Points Type R Value Area X WPM = Points Slab 272.0(p) -1.9 -516.8 1. Slab -On -Grade Edge Insulation 0.0 272.0(p 2.50 680.0 Raised 0.0 0.00 0.0 Base Total: -516.6 As -Built Total: 272.0 680.0 INFILTRATION Area X BWPM = Points Area X WPM = Points 1362.0 -0.28 -381.4 1362.0 -0.28 -381.4 EnergyGauge® DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004R FLRCSB v4.5.2 FILE COPY FORM 60OA-2004R EnergyGauge® 4.5.2 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details I ADDRESS: , , , PERMIT #: I BASE AS -BUILT Summer Base Points: 22397.4 Summer As -Built Points: 19558.8 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1: Central Unit 30200btuh ,SEER/EFF(13.0) Ducts:Con(S),Con(R),Int(AH),R6.0(INS) 1 22397.4 0.3250 7279.2 19559 1.00 19568.8 1.00 0.00 x 1.150 x 0.85) 0.260 0.983 0.260 1.000 1.000 5000.1 5000.1 k EnergyGaugeTM DCA Form 60OA-2004R EnergyGauge@/FIaRES'2004R FLRCSB v4.5.2 FILE COPY FORM 60OA-2004R EnergyGauge® 4.5.2 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT #: BASE AS -BUILT GLASS TYPES .18 X Conditioned X BSPM = Floor Area Points Type/SC Overhang Omt Len Hgt Area X SPM X SOF = Points .18 1362.0 24.35 6970.0 1.Single, Tint 2.Single, Tint Mingle, Tint 4.Single, Tint 5.Single, Tint 6.Single, Tint 7.Single, Tint 8.Single, Tint 9.Single, Tint 10.Single, Tint 11.Single, Tint W S N S N N N E S E S 2.0 4.0 8.0 2.0 5.0 12.0 2.0 5.0 9.0 2.0 6.0 24.0 2.0 5.0 18.0 2.0 4.0 12.0 2.0 4.0 6.0 2.0 5.0 9.0 2.0 6.0 24.0 2.0 4.0 6.0 2.0 6.0 12.0 47.90 39.84 24.46 39.84 24.46 24.46 24.46 53.27 39.84 53.27 39.84 0.74 0.75 0.88 0.80 0.88 0.84 0.84 0.81 0.80 0.74 0.80 283.0 359.0 192.0 762.0 386.0 245.0 122.0 386.0 762.0 235.0 381.0 As -Built Total: 140.0 4112.0 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adjacent Exterior 0.0 1362.0 0.00 1.90 0.0 2587.8 1. Concrete, Int Insul, Exterior 4.0 1362.0 1.20 1634.4 i Total: 1362.0 2587.8 As -Built Total: 1362.0 1634.4 [Base DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent Exterior 0.0 20.4 0.00 4.80 0.0 97.9 1.Exterior Insulated 20.4 4.80 97.9 20.4 97.9 As -Built Total: 20.4 97.9 rBaseTotal: YPES Area X BSPM = Points Type R-Value Area X SPMXSCM= Points 1362.0 2.13 2901.1 1. Under Attic 30.0 1362.0 2.13 X 1.00 2901.1 se Total: 1362.0 2901.1 As -Built Total: 1362.0 2901.1 OOR TYPES r Area X BSPM = Points Type RValue Area X SPM = Points b 272.0(p) 0.0 -31.8 0.00 -8649.6 0.0 1. Slab -On -Grade Edge Insulation 0.0 272.0(p -31.90 -8676.8sed Base Total: -8649.6 As -Built Total: 272.0 -867g.8 INFILTRATION_ Area X BSPM = Points Area X SPM = Points 1362.0 14.31 19490.2 362 14. 1 19490.2 EnergyGauge® DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004R FLRCSB v4.5.2 rILI: t;Upy ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 88.6 The higher the score, the more efficient the home. 1. New construction or existing New _ 12. Cooling systems 2. Single family or multi -family Single family _ a. Central Unit Cap: 30.2 kBtu/hr 3. Number of units, if multi -family l _ SEER: 13.00 _ 4. Number of Bedrooms 3 _ b. N/A 5. Is this a worst case? No _ 6. Conditioned floor area (ftz) 1362 ft' _ c. N/A 7. Glass type and area: (Label reqd. by 13-104.4.5 if not default) _ a. U-factor: Description Area 13. Heating systems _ (or Single or Double DEFAULT) 7a(Sngle Default) 140.0 ft2 _ a. Electric Heat Pump Cap: 21.0 kBtu/hr _ b. SHGC: HSPF: 8.50 _ (or Clear or Tint DEFAULT) 7b. (Tint) 140.0 W _ b. N/A _ 8. Floor types a. Slab -On -Grade Edge Insulation R=0.0, 272.0(p) ft _ c. N/A _ b. N/A _ c. N/A _ 14. Hot water systems 9. Wall types a. Electric Resistance Cap: 40.0 gallons a. Concrete, Int Insul, Exterior R=4.0, 1362.0 ftz _ EF: 0.97 _ b. N/A _ b. N/A c. N/A _ d. N/A _ c. Conservation credits _ e. N/A _ (HR-Heat recovery, Solar 10. Ceiling types DHP-Dedicated heat pump) a. Under Attic R=30.0, 1362.0 ft- _ 15. HVAC credits b. N/A _ (CF-Ceiling fan, CV -Cross ventilation, _ c. N/A _ HF-Whole house fan, 11. Ducts PT -Programmable Thermostat, a. Sup: Con. Ret: Con. AH(Sealed):Interior Sup. R=6.0, 200.0 ft _ MZ-C-Multizone cooling, b. N/A _ MZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant fe s. o Builder Signature: Date: ! 2 -��- Address of New Home: /0���` City/FL Zip: ( tC *NOTE: The home's estimated energyperformance score is only available through the FLA This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPA/DOE EnergyStar"" designation), your home may qualifyfor energy efficiency mortgage (EEM incentives ifyou obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 3211638-1492 or see the Energy Gauge web site at www.fsec. ucf edu for information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 8501487-1824. 1 Predominant glass type. For actual glass type and areas, see Summer & Winter Glass output on ages 2&4. EnergyGauge® (Version: FLPRCS> v4.5.2) Rhyac�.-,Residentiaf.&-Ught Commercial HVAC �qac Elite Software Development, Inc. ' N S6tAhetn, nt Camelot erpn§e§, 04 FortOiiarct FC34946 Page 8 Project title: 104 Camelot Designed by: Tammy Project date: Tuesday, December 09,2008 Project comment: Client name: Client address*. Client city: Client phone: Client fax: Client comment: Company name: Southern Enterprises Company representative: Tammy Company address: 4994 Deann Ln Company city: Ft Pierce Fl 34946 Company phone- 772-519-0019 Company fax. 772-4612775 Company comment: HzVAC, Equip-m- p-nt, Aem: -SystOn 1 Air Handier Name =I Cooling Description — Air Source Heat Pump Cooling Model Type Cooling Model Number UPNE-030J*Z+UHSA-HM3017+RCSA-H*3617A* Cooling Capacity 30,200 Btuh Cooling Efficiency 13 SEER Heating Description Air Source Heat Pump Heating Model Type Heating Model Number Heatifid.. Capacity 47°F: 33,400 / 17°F: 21,000 Btuh Heating Efficiency 8.5 HSPF FILE COPY Rlivac Residential Light Commercial HVAC Loads Elrte Software Development, Inc.: So` fern Enterprises 104 Camelot Fort Pierce, FL 3494E , : Page 7` SyStem 1 Room Load Summary ---Zone 1--- 1 Utility 110 2,463 32 2 Family Room 168 14,282 186 3 Kitchen 100 1,671 22 4 Bath 1 19 385 5 5 Master Bedroom 182 2,187 28 6 Dining 154 2,123 28 7 Bath 2 40 878 11 8 Bedroom 1 143 2,811 37 9 Living Room 182 2,296 30 10 Bedroom 2 143 2,992 39 11 Wic 121 564 7 1-6 474 2,046 52 93 93 3-6 478 6,189 308 282 282 1-7 532 3,123 22 142 142 1-4 13 25 _ 0 1 1 1-5 618 1,853 432 84 84 1-4 642 1,232 35 56 56 1-4 299 573 12 26 26 1-6 550 2,375 452 108 108 1-5 477 1,431 35 65 65 1-6 539 2,327 455 106 106 1-4 81 155 0 7 7 System 1 total 1,362 32,652 424 21,329 1,803 970 970 System 1 Main Trunk Size: 1205 in. Velocity: 776 ft./min Loss per 100 ft.: 0.093 in.wg Cooling S stani Summary Net Required: 1.93 92% / 8% 21,329 1,803 23,132 Recommended: 2.37 75% 125% 21,329 7,110 28,439 Actual: 2.52 75% / 25% 22,650 7,550 30,200 Eq'uj irient•Data;�- ° - Heating System Cooling System Type: Air Source Heat Pump Air Source Heat Pump Model: Indoor Model: Brand: Description: Efficiency: Sound: Capacity: Sensible Capacity: Latent Capacity. ARI Reference No.: Ruud UPNE Series Air Source Heat Pump 8.5 HSPF 47°F: 33,400 / 17°F: 21,000 Btuh n/a n1a n/a Ruud UPNE Series Air Source Heat Pump 13 SEER 30,200 Btuh 22,650 Btuh 7,550 Stuh 703070 FILE COPY Rhvac -Residential & Ligllt Commercial HUAC Loads Elite Software Development, Inc Southern Enterpnses` 104Cameiot= Fort Pierce; FL 34946-- System 1; Zone 1 Summary Loads (Average Load Procedure for Roofs) Area Sen L.a't °.' Seri Totef.. I'Coinponerit Descripton, _ LL . Quart , Loss.. . Gain ' -- Gain Gain ; 1A-cb-o: Glazing -Single pane, operable window, clear, 140 4,536 0 5,776 5,776 metal frame with break, u-value 1.08, SHGC 0.75 11 N: Door -Metal - Polystyrene Core 20.4 214 0 186 186 13AB-0ocb: Wall -Block, no blanket or board insulation, 1783.6 14,554 0 8,441 8,441 open core, brick finish 16C-30: Roof/CeilingzUnder Attic with Insulation on Attic 1194.2 1,146 0 1,529 1,529 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, White or Light Color Shingles, Any Wood Shake, Light Metal, Tar and Gravel or Membrane, R-30 insulation 16A-30: Roof/Ceiling-Under Attic with Insulation on Attic 168 161 0 376 376 Floor (also use for Knee Walls and Partition Ceilings), Unvented Attic, No Radiant Barrier, Any Roofing Material, Any Roof Color, R-30 insulation 22A-ph: Floor -Slab on grade, No edge insulation, no 272 11,083 0 0 0 insulation below floor, any floor cover, passive, heavy moist soil Subtotals for structure: 31,694 0 16,308 16,308 People: 6 1,200 1,380 2,580 Equipment: 0 3,400 3,400 Lighting: 0 0 0 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 29, Summer CFM: 15 958 603 241 844 System 1, Zone 1 Load Totals: 32,652 1,803 21,329 23,132 j Check Fi aces Supply CFM: 970 CFM Per Square ft.: 0.712 Square ft. of Room Area: 1,362 Square ft. Per Ton: 575 Volume (" of Cond. Space: 10,898 Total Heating Required: 32,652 Btuh 32.652 MBH Total Sensible Gain: 21,329 Btuh 92 % Total Latent Gain: 1,803 Btuh 8 % Total Cooling Required: 23,132 Btuh 1.93 Tons (Based On Sensible + Latent) 2.37 Tons (Based On 75% Sensible Capacity) Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. i Rhvac Residential Light Commetcial HVAC Loads Elite Software Development, Inc: Southern Enterpnses ' 104 Camelot Fort Pierce FL 34946°. Page 5' System 1 Summary Loads Component = Area Sen Lat �; Sen Total Dasri lion : 'L3uarr Loss Gain i, -Gain Gain 1A-cb-o: Glazing -Single pane, operable window, clear, 140 4,536 0 5,776 5,776 metal frame with break, u-value 1.08, SHGC 0.75 11 N: Door -Metal - Polystyrene Core 20.4 214 0 186 186 13AB-0ocb: Wall -Block, no blanket or board insulation, 1783.6 14,554 0 8,441 8,441 open core, brick finish 16C-30: Roof/Ceiling-Under Attic with Insulation on Attic 1194.2 1,146 0 1,529 1,529 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, White or Light Color Shingles, Any Wood Shake, Light Metal, Tar and Gravel or Membrane, R-30 rrrsuiadon 16A-30: Roof/Ceiling-Under Attic with Insulation on Attic 168 161 0 376 376 Floor (also use for Knee Walls and Partition Ceilings), Unvented Attic, No Radiant Barrier, Any Roofing Material, Any Roof Color, R-30 insulation 22A-ph: Floor -Slab on grade, No edge insulation, no 272 11,083 0 0 0 insulation below floor, any floor cover, passive, heavy moist soil Subtotals for structure: 31,694 0 16,308 16,308 People: 6 1,200 1,380 2,580 Equipment: 0 3,400 3,400 Lighting: 0 0 0 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 29, Summer CFM: 15 958 603 241 844 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 System 1 Load Totals: 32,652 1,803 21,329 23,132 .Check�Fj ores `- Supply CFM: 970 CFM Per Square ft.: 0.712 Square ft. of Room Area: 1,362 Square ft. Per Ton: 575 Volume (ft?) of Cond. Space: 10,898 S :stem",Loads Total Heating Required Including Ventilation Air: 32,652 Btuh 32.652 MBH Total Sensible Gain: 21,329 Btuh 92 % Total Latent Gain: 1,803 Btuh 8 % Total Cooling Required Including Ventilation Air: 23,132 Btuh 1.93 Tons (Based On Sensible + Latent) 2.37 Tons (Based On 75% Sensible Capacity) Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. FILE COPY -Sduthern EnWrphses., Elite Software Development, lnc: ,F Pierce'Fort L 404-Cam-610 __P -.34946,. aEle-4 Total Building Summary Loads Compo-nent'-­ Area Quan., Sen Loss Latt Sera- Gain Gain 'Total', Gain 1 A-cb-o: Glazing -Single pane, operable window, clear, I _ 40 4,536 0 5,776 5,776 metal frame with break, u-value 1.08, SHGC 0.75 11 N: Door -Metal - Polystyrene Core 20.4 214 0 186 186 13AB-Oocb: Wall -Block, no blanket or board insulation, 1783.6 14,554 0 8,441 8,441 open core, brick finish 16C-30: Roof/Ceiling-Under Attic with Insulation on Attic 1194.2 1,146 0 1,529 1,529 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, White or Light Color Shingles, Any Wood Shake, Light Metal, Tar and Gravel or Membrane, R-30 Insulation 16A-30: Roof/Ceiling-Under Attic with Insulation on Attic 168 161 0 376 376 Floor (also use for Knee Walls and Partition Ceilings), Unvented Attic, No Radiant Barrier, Any Roofing Material, Any Roof Color, R-30 insulation 22A-ph: Floor -Slab on grade, No edge insulation, no 272 11,083 0 0 0 insulation below floor, any floor cover, passive, heavy moist soil Subtotals for structure: 31,694 0 16,308 16,308 People: 6 1,200 1,380 2,580 Equipment: 0 3,400 3,400 Lighting: 0 0 0 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 29, Summer CFM: 15 958 603 241 844 Ventilation: ,..Winter .-CFM: .O.,-Summer CFM: .O 0 0 0 0 Total Building Load Totals: 32,652 1,803 21,329 23,132 7, Total Building Supply CFM: 970 CFM Per Square ft.: 0.712 Square ft. of Room Area: 1,362 Square ft. Per Ton: 575 Volume (11P) of Cond. Space: 10,898 Total Heating Required Including Ventilation Air: 32,652 Btuh 32.652 MBH Total Sensible Gain: 21,329 Btuh 92 % Total Latent Gain: 1,803 Btuh 8 % Total Cooling Required Including Ventilation Air: 23,132 Btuh 1.93 Tons (Based On Sensible + Latent) 2.37 Tons (Based On 75% Sensible Capacity) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. FILE COPY Rhv,,. -,R!esid!ential.&'Light.CbmMetclai,Hy4q,-',�.Qadt Elitejnc.r Ic'. Sbbth epj .,erpnse.,,-'I Q*Ca6@6t F60, Pierce FL,14946Pa [Load Preview Report 1 ! l Has; NetNet'Recl ft.11, 6en LatSys ' ! sysNet; Sew Sys; Duct Scope AED!� Ton' Ton' fToni Area Gain' Gain GainHfgClg! Loss' Act(SizeCM CFM' CFMI ............... Building 1.93� 2.37: 575, 11,362� 21,329� 1,803' 23,132� 32,652: 424: 970, 970 . ...... ....... .......... 1. w- I 1 -1-1 * I - -- I -**-*-, - — - 1— - -1 - . .. ... System I Yes. 1.93. 2.37,; 575" 1,362: 21,329 1,801" 23,113232,652: 424,9 i- ---970. -14.1.5. Zone I 1 3 6 2' 21 3 2 9; 1,803 23,132 32,652 424 l 970' 12x1 5 1-Utility 1102,046_ 522,098 2,463'. 32 II 93* 1-6 2-Family Room 168: 6,189: 308: 6,497, 14,282: 1860 282 3-6 3-Kitchen 1001 3,123, 22 3,145 1,671. 22 142: 1-7 4-Bath 1 19: 25 0 25: 385: 5 1 1-4 --------- --- 5-Master Bedroom 182: 1,853' 432' 2,285: 2,187: 28 84 1-5 6-Dining 1541 Y232, 35, 1,26T 2,123� 28 56: 1-4 ........... . ..... 7-Bath 2 40573: 12: 585: V& 11.M 26: 1-4 8-Bedroom 1 143: 2,375: 452: 2,827: 2,811- 37. 108: 1-6 9-Living Room ....... 182� .65. 1-5 10-Bedroom 2 143. 2,327. 455' 2,782 2,992; 39'M ... 106'.- 1-6 11 -Vvic 121 155. 0 155: 564� 7 1 7 1-4 FILE COPY va Rhc Residential &Light Commercial HVAC Loads Elite Software Development, Inc. Southern Enterpnses 104 Camelot. Fort-P-.i6r FL 34946' Pa eZ° Miscellaneous Report [System 1:.' Gutdoar,, u :Outdoors Ind£10f IndOUF °Grains° !r� 'utData.. ° .:D Bzrlb}/t $utb ,R61 t-#urn . ;: ;D.. 8u16... Difference' Winter: 42 0 30 72 3.44 Summer: 90 78 50 75 61.09 Dud Sizirt` Irtpur5 - Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 650 ft./min 450 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. nutside'Air Data ., - . Winter Summer Infiltration: 0.160 AC/hr 0.080 AC/hr Above Grade Volume: X 10,898 Cu.ft. X 10,898 Cu.ft. 1,744 Cu.ft./hr 872 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 29 CFM 15 CFM Total Building Ventilation: 0 CFM 0 CFM ---System 1— Infiltration & Ventilation Sensible Gain Multiplier: 16.49 = (1.10 X 0.999 X 15.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 41.50 = (0.68 X 0.999 X 61.09 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 32.97 = (1.10 X 0.999 X 30.00 Winter Temp. Difference) Rhvac - Residential & •Light;Commeteial HVAC: Loads ,- Southern Enterprises; Elite Software Development, Inc.' - " 104'Cam elof FortPierce`Fl .84946age Project Report General�Psoject;lnforrriation °- -�' ' '" - Project Title: 104 Camelot Designed By: Tammy Project Date: Tuesday, December 09, 2008 Company Name: Southern Enterprises Company Representative: Tammy Company Address: 4994 Deann Ln Company City: Ft Pierce FI 34946 Company Phone: 772-519-0019 Company Fax: 772-461-2775 .Desr n=Data771 Reference City: Fort Pierce, Florida Daily Temperature Range: Medium Latitude: 27 Degrees Elevation: 25 ft. Altitude Factor: 0.999 Elevation Sensible Adj. Factor: 1.000 Elevation Total Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Dry Bulb Difference Winter: 42 0 30 72 3 Summer: 90 78 50 75 61 ,Check Figures :.. - Total Building Supply CFM: 970 CFM Per Square ft.: 0.712 Square ft. of Room Area: 1,362 Square ft. Per Ton: 575 Volume (ft3) of Cond. Space: 10,898 Buildin Loads , - .. Total Heating Required Including Ventilation Air: 32,652 Btuh 32.652 MBH Total Sensible Gain: 21,329 Btuh 92 % Total Latent Gain: 1,803 Btuh 8 % Total Cooling Required Including Ventilation Air: 23,132 Btuh 1.93 Tons (Based On Sensible + Latent) 2.37 Tons (Based On 75% Sensible Capacity) Notes :.: - Calculations are based on Bth edition of ACCA Manual S. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads.