Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SUBMITTED PAPERS
PLAN REVIEW FEE: y RECEIPT NO.: (p (o g� PERMIT NUMBER: CONCURRENCY FEE: RECEIPT NO.: CERT. CAP. NO.: ALL INFO MUST BE COMPLETE & FILLED IN TO BE ACCEPTED St. Lucie County Building and Zoning qV$?& m> SCANNED 2300 Virginia Avenue �Q� �ORIp BY Ft. Pierce, FL 34982-5652 772-462-1553 IV OT U)V P - P St. Lucie County APPLICATION for BUILDING PERMIT CERTIFICATE of CAPACITY/ZONING COMPLIANCE 1. LOCATION/SITE ADDRESS 2. NOPROJECT NAME: e3Rl Cr, 3. 4. PROPERTY TAX ID #: PROJECT INFORMATION r&PNCA) Lsus / a665 Hem i n q uubol Cf- SITE PLAN NAME: LEGAL DESCRIPTION (attach extra sheets if necessary): �t�� tC�l� �-s Udl1C- 08 5. PLAT BOOK 6. PAGE NO. 9. PARCEL SIZE (ACISYQ FT.): 7. BLOCK NO. LOT DIMENSIONS: E:#MM0911 10. COMPLETE DESCRIPTION OF CONSTRUCTION PROJECT OR WORK ACTIVITY: �'nS��i>0rc)N Svs b ran roc; s�-o �� s�a4� u r��Pr �x � �.�-►`h � �d roar- i 11. SETBACKS (ACTUAL) FRONT: N BACK: RIGHT SIDE: 12. TYPE OF CONSTRUCTION (Check all appropriate boxes) [ ] NEW CONSTRUCTION [ ] EXPANSION/ADDITION [ ] RESIDENTIAL [ ] COMMERCIAL [Zg, OTHER (SPECIFY) AGt,-\A; CPkp o+eX l'!54 ft ait LEFT SIDE: [ ] INTERIOR RENOVATION [ ] INDUSTRIAL 13. DESCRIPTION OF PROPOSED USE: 9 re-D\QC�. ��*iS r®- :1 SS kCqj 14. T61 SQ. FT OF CONSTRUCTION: VALUE OF CONSTRUCTION: $ 15. SF. FT Ist FLOOR: The value of construction is used to determine the amount of permit fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction activities. If the value is $2500 or more, a RECORDED Notice of Commencement must be submitted with this application. SLCCDV Form No.: 001-02 OWNER INFORMATION NAME: _Uc�r ee 1 % a ADDRESS: p V5420S `�er\;,naU0a1/ �•�• i rd�` CCa\ 5� CITY: �� - ` 1 e rg STATE: ZIP:' PHONE (DAYTIME): Wiz) 6y - Z$7 Email: IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE, PLEASE FILL IN NAME AND ADDRESS BELOW. FEE SIMPLE TITLEHOLDER: ADDRESS: CITY: STATE: ZIP: PHONE (DAYTIME): (_) •. r' CONTRACTOR INFORMATION ST. of FL REG.CERT #: ST. LUCIE COUNTY CERT BUSINESS NAME: o �� �re`\ QUALIFIERS NAME: (n1C \ ADDRESS: lk1O\ CITY: VA- . "? STATE: �� ZIP: PHONE(DAYTIME): (17Z) . -3i0- [(bLq FAXNO'77Z T6ZI70Emai1: ARCHIT/ENGINEER- = c n 2)A ADDRESS: CITY: STATE: ZIP PHONE (DAYTIME): (_) BONDING COMPANY: ADDRESS: CITY: MORTGAGE LENDER: ADDRESS: CITY: STATE: STATE: ZIP: ZIP: 347gz. IMPORTANT NOTICE: When a permit is issued and it is not picked up within 60 days after notification it will be voided and returned to you by mail. 4 . CERTIFICATION: This application is hereby made to obtain a permit to do the work and installations as indicated, and to obtain a certificate of capacity, if applicable, for the permitted work. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits may be required for ELECTRICAL, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AND AIR CONDITIONERS, ETC., not otherwise included with this building permit application. St. Lucie County makes no representation that its granting of a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Homeowner Association rules, bylaws or any covenants that may restrict or prohibit such structure. Please consult with your Homeowner's Association and review your deed for any restrictions which may apply. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures (all types), swimming pools, fences, walls, signs, screen rooms, utility substations & accessory uses to another non- residential use. NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE TO APPLICANT: AS THE APPLICANT FOR THIS BUILDING PERMIT, IF IT IS NOT YOUR RIGHT, TITLE, AND INTEREST THAT IS SUBJECT TO ATTACHMENT; AS A CONDITION OF THIS PERMIT YOU PROMISE IN GOOD FAITH TO DELIVER A COPY OF THE ATTACHED CONSTRUCTION LIEN LAW NOTICE TO THE PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. C, OWNER OR CONTRACTOR SIGNATURE CONTRACTOR SIGNATURE STATE OF FL RID COUNTY OF 9'I' u.CIC The foregoing instrument was acknowledged before me this 11 day of 200 by hael(Y.J 1 6 - %nK1 e who is personally known )� or has produced STATE OF FLWA COUNTY OF uLl2. The foregoing instrument was acknowledged before me this I i day of NAOU V , 2001, by AOC \61%0,44 who is personally known or has produced as identification. / as identification. 'N�Ad I Signature of Nota y Signature of No a Commission No. ° Commission No. 1),0� �� V-wovil* MY MMISSION ADD 1YMEXPIRES: October 3,2011 �LW#NOIS40h()3AYV BondedThmB M MMI ••' & NOTE: TWO (2) SIGNATURES ARE REQUIRED. EACH SIGNATURE MUST BE NOTARIZED. IF APPLYING FOR THIS BUILDING PERMIT AS AN OWNER/BUILDER, THE OWNER MUST PERSONALLY APPEAR TO SIGN THIS APPLICATION IN THE OFFICE LISTED ON THE FRONT OF THIS APPLICATION. OWNER BUILDER AFFIDAVIT WILL BE REQUIRED FOR ALL OWNER/BUILDER APPLICANTS. For specific instructions see appropriate permit checklist. OFFICE USE ONLY BP #: SECTION j 0 TOWNSHIP RANGE (/0 MAP NO.oA F ZONING® , J (/L LAND USE Ru LOT CVG % TAZ NO. FLOOD ZONE FIRM MAP # 1ST FLR ELV MAX HGT CONST TYPE OCCUP TYPE OCCUP # OF FLRS WATER SEWER SPRINKLERS STORMWATER LOT OF REC LOT OF REC LOT SPLIT LOT SPLIT Before 1/1990 After 1/1990 REQUIRED APPROVED REPORT HABITABLE RADON PERMIT CODE 9 l AREA FEE FEE (RADON) LIBRARY PUBLIC BLD PUBIC BLD PARKS IMPACT IMPACT FEE IMPACT IMPACT FEE CORRECTION FEE FEE GENERAL SCHOOL ROAD CREDIT Y N LAW ENF IMPACT IMPACT IMPACT FEE FEE FEE FIRE/EMS DRIVEWAY . Y N DRIVEWAY ADMINISTRATIVE IMPACT REQTJME "E1_= , FEE VARIANCE+FEE FEE SPECIFY MECHANIC = ROOF NON -CONFORMING MISCELLANEOUS SUBS ELECTRIC ; ' ': - GAS LOT OF RECORD ? ;FEES; ' '> REQUIRED PLUMBING FEES •t DATE SENT TO ADDRESSING: REVIEWS FRONT ZONING_ �' SUPERVISOR PLANS VEGETATION SEA TURTLE : " MANGROVE COUNTER REVIEW : ' ,, REVIEW REVIEW REVIEW REVIEW i REVIEW DATE RECEIVED DATE Mtt COMPLETED +'" /o'f • /�• INITIALS e J Chichiou Liu, M. D. South Beach Family Practice 1102 Colonnades Drive Fort Pierce, IL 34949 772-466-0200 October 22nd, 2008 To whom it may concern: Please be advised that Mr. Darrell Hinkle has been under my care for many years. Due to multiple medical problems, the patient will benefit by being able to use the vertical platform lift. Thank ou Chichiou ]Liu, M.D. C ` NOV 4 2008 2" Circle Fare Pam, FL P2mm/Fam 77Z 4*84 + " APPR0VAL 9W.UEST DATE: NAME: 7 a r; eC.L ADDRESS: �G 1 t �Y� 1 i T L r# C p- 8' POWT APPIUM FOR FL ROOM _,_ _SCMM ROOM CARPORT ROOF UTII.IIYROOM AWNING ALL ADDITIONS MUST' BE ATTACHD TO THE HOME AMID MUST MEET PARK SPECIgiCKnows. AIL ADDITIONS MUST BE APPROVED W- ADVA BY THE PARK OMCE. ALL VENDORS AMID COPITRACTORS MUSP BB LIC'ENSEDBy IM DTEA S CSOUNTY AMID MUST SHOW EVIDENCE OF INSURAWM � OM )CLL A COVER MUST COMPLY WITH LOCAL OPMWAWM AND BUIIMI�►iti CODES. _ OW PAMOSMU5rMAUZMM3WBWoNnMHOUSL DRAWING ATTAC. nD pIm APPROVAL ___Lts (fir-, ANY CKANGES TO YOUR %MMnrfW DRAWM MW WOMW BEWW). C0NTRACWWSxAME.oP V��cc'�•fi i s 3 Y-:A,d/%a n iJe . rfo " F� Pi 1 •. • t•`Phi :+• J' ,1 i 1 '! ,1 t: / • is •,. iM: • ai . t:,l �:,. •. 4:1 • • I .:• N:•< .1 �: , • 1 s•� ,i, is '«.� .i.� • •� Top Drawer Cabinetry Carpentry, I' ~ (772) 370-4624 PROPERTY RECORD CARD Darrell B Hinkle Record: 1 of 1 <<Prev ` Next» Spec.Assmnt Taxes Exemptions Permits Home Print Property Identification Site Address: 5556 S US HWY 1 Sec/Town/Range: 10:36S:40E Map ID: 34/10N Zoning: CG Ownership and Mailing Owner: Darrell B Hinkle Mary Ellen Pizzi Address: 5665 Hemingway Ct # C-08 Fort Pierce FL 34982 ParcellD: 3410-508-0047-000-8 Account #: 172541� Land Use: CPRATVES City/Cnty: ST. LUCIE COUNTY ' Legal Description !�DP�CALISL'ES(O� R 86'2 63 UNITQ8 ��283 Sales Information Assessment 2008 Final Total Land and Building Date Price Code Deed Book/Page 2008 Final: 53400 Land Value: 20000 Acres: 0.13 5/24/2007 100 01 MS 2834 / 2955 Assessed: 53400 Building Value: 33400 4/19/2007 100 04 PR 2802 / 2171 Ag.Credit: 0 Finished Area: 1048 SgFt 4/11/2007 15000000 02 WD 2802 / 2168 Exempt: 28400 Taxable: 25000 Taxes: 502.41 BUILDING INFORMATION C Exterior Features View: - RoofCover: - ExtType: MH - ManufacHse YearBlt: 1995 Grade: H - H EffYrBlt: 1995 StoryHght: 0010 - 1 Story No.Units: 1 Interior Features RoofStruct: - Frame: - PrimeWall: - SecWall: - BedRooms: 0 Electric: MX - MAXIMUM PrmintWall: - FullBath: 0 HeatType: FHA - FrcdHotAir AvgHUFI: 1/213ath: 0 HeatFuel: ELEC - Electric Prm.Flors: - %A/C: 100 %Heated: 100 %Sprinkled: 0 Special Features and Yard Items Land Information Type Y/S Qty. Units Qual. Cond. YrBlt. No. Land Use Type Measure 1 0500-CPRATVES 127 -Site 1 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED Depth Top Drawer Cabinetry Carpentry, LLC (772) 370-4624 THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORST MAY BE NECRUARY IN ORDER T® 4006Y WITH Al AFPW A COOK Lq f pQv3r% FILE ¢OPY oY►A-aria CONCEALED PASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD zz oj? ST. LUCIE Coubm BUILOIN©D N REYI DATE a - 4 1-- PLAN)rAND PERMIT ONJ MUST B KEPT ON JOB OR NO INSPECTION WILL SE MADE Vertical :Platform Lift A' Read manual thoroughly This: manual 'has" been. provided, to.!assist: ,You with lift Install tios l=or, further .assistance,you 0.1.0aso authorized :Harm -au Mobility dealer: or- Harmar' sTechniclal 5ervices4epprtment, Tek-8.00.8.3104478 Fax:8 66.234-0478, Emai.l':'t",echOhalrm-.,a,r.,com ;OPT atte- mptihqta instal . I . or operate rift. rtal "4— Wit-, Table of Contents Installing the lift Using the Manual 2 When You Receive the Lift 3 Specifications 3 Safety 4 Code Requirements 5 Site Requirements 5 Reauired Tools 5 Required Materials 5 Preparing to Install the Lift 6 Anchoring the Lift g Setting the Limit Switches g Verging Operation of the Lift 11 Trouble Shooting 12 Manual Override 13 Exploded View 14 Exploded View 15 Wiring Schematic 16 Operating the lift Safety � g Controls 19 Operating the Lift 20 Service Log 23 Usi na the Manual This manual will provide step by step instructions on how to install and operate your lift. Read and understand the entire manual before beginning to install the lift. i If you have any questions , contact Harmar Access technical service at 1-800-833-0478 When You Receive the Lift • Check the lift for shipping damage. If you see any damage contact the freight carrier to file a damage claim. • Verify the products match that described on the packing list attached to the exterior packaging. • Verify the contents of the package match that shown below to the right. specifications Payload Capacity 750 Ib Vertical Travel (PL200) 28 in (PL400) 52 in (Diann) 7)in Height (PL200) 44 in (PL400) 68 in (PL600) 88 in Foot Print 48.75x70 in Platform Size 34 x 52 in Input Voltage 110 v ac Control Voltage 24 it ac Platform Speed 1 4 in/sec Motor 1/2 ho Code Requirements Your lift has been designed to meet ASME A18.1 and CSA B44/ASME A17.5. Code requirements for Vertical Platform lifts vary depending on location. It is.the installers responsibility to contact their local code enforcement office and determine all of the regulations they are subject to. You must do this before installing the Vertical Platform Lift, Site Requirements The lift will require a 115 vac 20 amp grounded circuit. Only install the lift on a 4" thick, level 3,500 psi reinforced concrete slab. Foot Print 48.7500 in (this includes the folding access ramp) Rea u i red tools ? 112" Hammer Drill ? 112" Masonry Drill Bit ? Appliance Dolly ? Hammer ? Level ? Measuring Tape ? Socket Wrench Set ? Shop Vacuum Reauired materials • 4 Floor anchors Harmar Access recommends securing the lift using our PL001 Anchor Kit. If you purchase you own floor an- chors they must use 1/2-13 bolts and have a minimum tensile strength of 6000 LBS. Preparina to Install the Lift Final Site Inspection Verify the surface the lift will mount to is smooth and level. This surface must be made from 3,500 psi re- inforced concrete with a minimum thickness of 4". Verify that there is enough space for the lifts foot print. Be sure to include space for the folding access ramp. (48.75x70 in) Caution: Verify that .the run- ning clearance around the lift complies with any codes for your area. Verify that sufficient head room exists above the lift. The lift will require 8' of clearance above the platform floor when the lift is at the upper landing. Connectina to Electricit The lift will require a 115 VAC 20 amp grounded electrical outlet within 6 feet of the lift. Plug the lift directly into the power outlet. Do not plug anything else into same outlet as the lift. Warning: Do not ride on the lift until it has been anchored in place. Reversina the Ram Depending on your application the access ramp may be removed and installed on the opposite side of the platform. If this is required complete the following steps. Step 1 Remove the four bolts that attach the ramp mounting tabs. This will allow the ramp assembly to be re- moved from the platform. Step 2 Remove the bolts that attach the " U " bracket to the side of the lift. Set the "Bracket aside and reinstall the bolts in the holes they came out of. Step 3 Reinstall the "U" bracket on the opposite side of the lift. Step 4 Attach the access ramp by bolting the ramp mounting tabs to the opposite side of the lift. Warning: All bolts must be re- attached with lock washers. Be sure to tighten the bolts suffi- ciently to prevent loosening. Anchori na the Lift Step 1 • Position the lift in its final location. • Verify that it is level and perpendicular to its sur- roundings. • Shim if necessary. Anchors Harmar Access recommends securing the lift using our PL001 Anchor Kit. If you purchase you own floor an- chors they must use 1/2-13 bolts and have a mini- mum tensile strength of 6000 LBS. Warning: All four floor anchors must be installed correctly in accordance to their instructions. Step 2 Use the lift's base as a template. Drill 4 holes into the. concrete. Verify that the holes you have drilled are deep enough to accept the anchors. Tip: Concrete dust may have set- tled into the holes you just drilled:" Use a shop vacuum to clean out these holes. This will ensure the floor anchors set cor- rectly. Step 3 Secure the lift in place by tightening the floor anchor bolts. Setting the Limit Switches Your lift is equipped with upper and lower limit switches. The vertical location of these switches may be adjusted to fit your application. Typically the upper limit switch will need to be adjusted so the platform will stop level with the upper landing. The lower limit will typically not need adjusting. Step 1 Verify the key and emergency switches are in the ON position. Run the lift in the up direction until the plat- form floor is level with the upper landing. Unplug the lift's power cord from the wall. Before going to the next step. Warning: Moving components can cut and crush. Do not operate the lift if you are in close proximity to any drive components. Be aware that loose clothing or jewelry may catch on moving parts. Step 2 Remove the screws at the top of the lift that attach the front cover. Step 3 Remove the front cover by tilting it forward and the lift- ing upwards. Set the cover aside in a safe location where it will not get damaged. Step 4 Loosen the set screw that attaches the upper limit switch assembly. Slide the assembly down the track until the lower switch in the assembly comes in con- tact with the lift's car. You should hear the limit switch click as contact is made. Retighten the set screw fastening the limit switch assembly in place. Step 5 Replace the front cover and secure it with the screws you removed in step 1. Step 6 Plug the lifts electrician cord into the wall. Verify that the key and emergency switch are in the on position. Step 7 Run the lift in the down direction for several inches. Next, run the lift in the up direction. Continue to press the up button until the upper limit switch has caused the lift to stop. Step 8 Verify that the platform has stopped level with the upper landing. If it has not, readjust the limit until it is level. N � (l verifying Operation of the Lift Caution: Complete the follow- ing section before training the customer to use the I ift. Step 1 Run the lift up and down for 5 complete cycles. Hold the direction button down and allow the limit switches to stop the lift. At the top, verify that the platform stops level with -the upper landing. At the bottom, verify the access ramp unfolds and rests on the ground. Step 2 Verify the operation of the Emergency stop switch. When this switch is pushed the lift should not run in either direction. When this switch is pulled back out, the lift should operate normally. Step 3 Verify the operation of the sensor pan underneath the platform. Start with the lift at the top landing. Press up on the sensor pan. While holding the pan in this loca- tion, press the down switch on the platform. The lift should not run. Warning: Do not run the lift if anyone is under the platform. Trouble Shooting PROBLEM CAUSE Lift will not operate up or down. Key switch in "OFF" position. Lift only moves in the "UP" direction. Emergency switch depressed. Power cord unplugged The building's circuit breaker has tripped. Insufficient incoming power. A final limit switch is engaged Pan limit switches engaged. Acme nut safety switch engaged Lower initial limit switch engaged or faulty. Faulty "DOWN" push button switch. Faulty "DOWN" relay Lift only moves in the "DOWN" Upper initial limit switch engaged or direction. faulty. Faulty "UP" push button switch. Faulty "UP" relay. SOLUTION Turn key to "ON" position. Pull emergency out. Plug the cord into the outlet. Locate building's circuit breaker box and reset the circuit breaker. Lift must connected directly to a dedi- cated 20A circuit. Inspect and reposition the limit switches. Check for and remove any obstruc- tions under lift platform. Inspect acme nuts for signs of failure. Contact Harmar Access for assistance. Adjust or replace limit switch. Press red test button on "Down" re- lay. If lift now moves downward, re- place down switch. Test relay by pressing red test button. If lift does not operate, replace relay. Inspect and adjust or replace switch Press Red test button on "Down" relay. If lift now moves downward, replace down switch. Test relay by pressing red test button. If lift does not operate, replace relay. If you have any questions , contact Harmar Access technical service at 1-800-833-0478 Manual Override Your lift is equipped with a manual override, to be used in the case of a power failure. Step 1 Before using the manual override verify that it's use is required. Check that the key switch is in the ON posi- tion and that the emergency stop switch is pulled out. Check that the electrical cord is plugged into the wall. Also check that the buildings circuit breaker has not tripped. Try to run the lift by pushing both the up and down buttons. If the lift still will not run, complete the following steps: Step 2 Unplug the lift from the wall. Warning: Do not service or operate the manual override while the lift is connected to electricity. Step 3 Remove the screws that attach the manual override cover plate. Remove the plate and set it aside. Step 4 Insert the manual override key through the access hole and into the hex socket on the motor. Rotate the key to raise or lower the platform. If the lift is near the top landing, the car assembly will start to interfere with the manual override tool. The tool functions through a range of angles. As the car assembly nears the tool, lean the tool away from the car. When this is no longer possible, remove the tool and reinsert it through the access hole in the car assembly. Tower Exploded View �ASSEM6LV KARTS. n,Ew ort ,4 1 Kom 7127 1p SHAFT.jqpR 1 41 TOM. 1 rr.SHOULDERBqLT 0- Ii75023Y' WA Fkk !i750576 ACME LEA,DG�-'F," io, 2 H150585 P.'OkHIJFfAXU li 4 FR5650I -AAINROLCERASSY 12 4 13 1 H750590 14 T H756591 U14h A68rweoy- 15 AC14EP S 16 MOIORTACER. 17 1 H750994, LqVVER13YT!W. Platform Exr)loded View ;lTuf PART w I 41iOA sa '2' 41 058 3 1 7. .12 Ainogi 45 IOD I I a.,...m.......�����,rr�l P,���........,...��,:.�>���,�m:�,� � Riff 65s� � 9GT I r I ------------- - s iUn i ) Id I . 3 I xi i t� I i I I n I TO ter iI 1 .... ..... .m....... . Harman Corp. TETLD poftr,-lift Docum.ent Neer: Acid OM n date: V559 vio- sheep i/i E3 Vertical Platform Lift - Owners Section Read the manual thoroughly before operating the lift. Congratulations on.the purchase of your Harmar Access Vertical Platform Lift. This lift has been engineered to provide trouble free service for many, many years. Please read this manual completely before operating your lift. Safety • Do not exceed the maximum payload capacity of 750 Ibs (340 kg). • Do not ride on the lift until it is anchored in place. • This product is designed only for lifting people and wheel chairs. Do not use it for any other purpose. • Make sure any obstructions are cleared from underneath the platform area before use. • Make sure both the passenger and wheelchair are completely on to the platform before using. • Do not disable any safety equipment or switches supplied with this lift. • Do not attempt to service the lift yourself. Contact your Harmar Access dealer for assistance. • Always turn the key switch to the OFF position and remove the key when the lift is not in use. • Do not allow children to operate or play around the lift. 0 Read all instructions in this manual before installing or operation the lift. C/ Controls Key Switch This switch allows the lift to be locked in the off posi- tion. Always turn the key switch to the "Off" position and re- move the key when the lift is not in use. Emergency Stop In an emergency push this red button to stop the lift. Up Controls upward movement of lift platform. To move platform up, depress and hold the upper half of the tog- gle plate. To cease movement, release toggle. Down Controls downward movement of lift platform. To move platform down, depress and hold the lower half of the toggle plate. To cease movement, release toggle. Operating the Lift IMPORTANT! Your Vertical Platform Lift is designed with a time de- lay system. When you press the Up or Down switch the lift will pause for 2 seconds before moving. This feature will prevent unwanted movement caused by accidentally bumping the UP or DOWN switches. Step 1 - Up Drive onto and stop in the middle of the platform. Ap- ply the brakes of your chair or scooter. Step 2 Insert the key into the key switch and turn clockwise. Verify that the emergency stop button is not activated by giving it a quick pull out, away from the side of the plat- form. Step 3 Press and hold the UP button. The lift will move in the up direction and stop when it reaches the upper landing. Warning: Always verify the lift's platform has stopped level with the upper landing. If not contact you Harmar Access Dealer for as- sistance. Step 4 Turn the key switch counter clockwise and then re- move the key. Release the brakes on your chair or scooter and drive off the platform. Step 1 - Down Drive onto and stop in the middle of the platform. Ap- ply the brakes of your chair or scooter. Step 2 Insert the key into the key switch and turn clockwise. Verify that the emergency stop button is not activated by giving it a quick pull out, away from the side of the plat- form. Step 3 Press and hold the DOWN button. The lift will move in the down direction and stop when it reaches the lower landing. Warning: Always verify the lift's ac- cess ramp unfolds fully and rests on the ground. If not contact you Harmar Access Dealer for assistance. ODerating the Lift Step 4 Turn the key switch counter clockwise and then re- move the key. Release the brakes on your chair or scooter and drive off the platform. .�Velhaven and Associates 800.,^, i__--____._.._._............._..._...----.............____............... .......... .......... _.... __------ _----- ...... ...... _.__......_..._____.... Abingdon at Tradition Monday, November 24, 2008 11:16 AM I From: "Sonja Warren" <SWarren@Abingdon-Tradition.com> To: "Welhaven Holdings" < we] haven@bellsouth.net> f....... .._...................._...._........,..........._.�..,_..............�........_....._...s.__._......._......__..`.__'.__. Hi Lourdes, Hope you're doing well. We're ready to order more water again O Can you ship us 9 cases. No rush, we don't need them until January 25. Sonja F. Warren Abingdon at Tradition Director of Sales and Marketing 10489 SW Meeting Street Port St. Lucie, FL 34987 772-345-2700 Office 772-345-2701 Fax www.abingdon-tradition.com 4;00>0000� 1-la ar MOBILITY ENGINEERING DIAGRAMS PRODUCT: V P L s168L61.8LY'P4RF REM OTY PART W: DESCRPRON MOM `2 1 H150223 REAR80Y,'(66HTAVLE) 3. t HR5022,e TAPEREDRa11ER8EA§N( A t W, W227 t!? IQ SHRFT 00LOR .5 ; W50229 1/?SHO.ULDERDOLT 6 8 Hf50337' t�JA4MER. 7 1 M50400. FRAMEABBEM10 8 1 }iZ50300' 'CAFtASSEMBLY 0 1• KOM . ACME LEAD SCREY,(PORPL60% 10 2 H758585 PORCHUFT AXLE ; HT 0587 MAINRCILIERAM 12 ;. Hl50598 SECONEAi Y R011ER� .13 1 H750590 .MOTOR BRACK TA89.EMBLY W50591 UMITA8864GLY. 15 1 .H7.56595, %GME.Nfs 16 t M59KC MOTOR SPACER' 17 t 1 FU50994 I L0WpR8VEF4IWO. HARMAR MOBILITY - 2075 27TH ST - SARASOTA, FL 34234 - 866.351.2776 - WWW.HARMAR.COM Ha ar MOB/L/TY PRODUCT: V P L (t734 OM 1'AR7 HS 2 2 81259A57 3 1 H75022 x 1 H75024: H75M 0 — H750504 7 1 H75o 9 2. .H7505V A 1 H75o5tA 10 1 hk?50813 17 1 H75051i A2 2 H750715 .l� 'a H7508iL3 14 2 H75W751 1S 1 H7509W 16 2 J240W120.35 .17 2 TU2:200.180.3E ENGINEERING DIAGRAMS HARMAR MOBILITY - 2075 27TH ST - SARASOTA, FL 34234 - 866.351.2776 - WWW.HARMAR.COM 38.3 J MODEL # TRAVEL TOWER HEIGHI MAX HEIGHT PL600 72.0 MAX 88.1 107.8 PL400 52.0 MAX 68.1 87.9 PL200 28.0 MAX 44.1 63.9 RATED LOAD 750 LBS MAXIMUM POWER SOURCE 115 VAC 20AMP'GROUNDED CIRCUIT CONTROL CIRCUIT VOLTAGE 24 VAC DRIVE 1/2 HP SINGLE PHASE 3450 RPM INTERMEDIATE REDUCTION 10:1 F3IGHTANGLE WORM GEAR BOX FINAL DRIVE 1" DIA ACME SCREW W/ BRONZE NUT & SAFETY BACKUP NUT EMERGENCY STOP RED MUSHROOM HEAD BUTTON SPEED 8 FEET/MIN MAXIMUM MANUAL OVERIDE YES KEY SWITCH YES PLATFORM CONTROL LARGE TOGGLE SWITCH (REQUIRES CONSTANT PRESSURE TO OPERATE) SURFACE FINISH POWDER COAT SAFETY FEATURES REDUNDANT LIMIT SWITCHES SAFETY PAN BENEATH PLATFORM NONSKID SURFACE 1 DESCRIPTON NAME DATE C 54.0 34.2 - - -y 32.0 CENTER OF CONTROLS 36.0 SIDE WALL' f 7.8 j MAX HEIGHT i . TOWER HEIGHT TRAVEL CONFIDENTIAL INFORMATION i NOTTO BE COPIED OR USED I WITHOUT WRITTEN CONSENT 1 - UN LESS OTHERWISE SPECIFIED DWG NO. A i DIMENSIONS ARE IN INCHES. - TOLERANCES ARE: VERTICAL PLATFORM LIFT !j DESCRIPTION .` DO NOT SCALE DRAWING A SPECIFICATIONS MATERIAL FINISH DRAWN BY DATE ACCESS RAMP CAN BE MOUNTED ON RIGHT OR LEFT SIDE � JEFFDWAL 8-3441 - �:/ I •" SCALE: 0.0. SIZE B SHEET 1 OF 1 FOR ENGINEERING ONLY r� PTOEn m-, File ( ASSE14: PL60D 3 .......... .............. _. Diawin : VPL DIMENSIONS ... ............ _................. _........... _... ...... _............. _.................................................................................. __... _.................... .................. _............. ...... _...... _............................. _._..................... ...... .... ..... _.............. S , _.................. .................. _...... ......................_........ __......................... 9