Loading...
HomeMy WebLinkAboutSUBMITTED PAPERS®AW,.n 8?� RECEIPT NO.: RECEIPT NO.: PERMIT NUMBER:y 0/ ��-- CERT. CAP. NO.: ALL I*P-MUST BE COMPLETE &IgILLED IN TO BE ACCEPTED St.. Lucie County Building and Zoning 2300 Virginia Avenue •'c�flRl�P• SCANNED Ft. Pierce, FL 34982-5652 NE® 772-462-1553 BY i 'St. Lucie County v APPLICATION for BUILDING PERMIT CERTIFICATE of CAPACITY/ZONING COMPLIANCE PROJECT INFORMATION 1. LOCATION/SITE ADDRESS: 7601 Donlon Road Fort Pierce, Florida 34951-1771 2. 3 S/D NAME: Lakewood Park SITE PLAN NAME: . PROPERTY TAX ID #: 1301-605-0095-000/6 4. LEGAL DESCRIPTION (attach extra sheets if necessary): Lakewood Park Unit 5 Blk 43 Lots 24 and 25 (Map 13/11N) (OR 403-2846) 5. PLAT 0403 6. PAGE 2846 BOOK NO. T BLOCK43 NO. S. LOT 24 & 25 NO. 9. PARCEL SIZE: ACRES/SQ FT. 0.46 LOT DIMENSIONS 150 X 132 )9j - DO. 10. DESCRIPTION OF CONSTRUCTION PROJECTOR WORK ACTIVITY: Remove old and rotted T-11 siding and :replace it with 918 inrh plywnorig. p1ji- in #30 felt paper �R- a wind- and water barri r and attach Hardie Board and Hardi Plank. IL SETBACKS (ACTUAL) FRONT: BACK: RIGHT: LEFT: 15 f t SIDE SIDE . 12. TYPE OF CONSTRUCTION (Check all appropriate boxes) [ ] NEW CONSTRUCTION [ ] EXPANSION/ADDITION [ ] INTERIOR RENOVATION [) RESIDENTIAL [ ] COMMERCIAL [ ] INDUSTRIAL [] OTHER (SPECIFY) Replace exterior siding and install Hardi Board and Plank 13. DESCRIPTION OF PROPOSED USE: Rpsi denti a 1 14. 16. Sq. Ft./CONSTRUCTION: 1026 sq f t VALUE OF CONSTRUCTION: $ 1500.00 15. Sq. Ft. I st Floor: 1026 sq ft Ile value of construction is used to determine the amount of permit fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction activities. If the value is $2500 or more, a RECORDED Notice of Commencement must be submitted with this application. SLCCDV Form No.: 001-02 OWNER INFORMATION NAME: Robert Spring ADDRESS: 7601 Donlon Road Fort Pierce STA7[TE:. Florida ZIP 34951-1771 .CITY: _ - _ PHONE (DAYTIME); 7( _72 ) 465-3888 email: b; s 1tse-east . �ret--- IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM -THE OWNER LISTED ABOVE, PLEASE FILL IN NAME AND ADDRESS BELOW. FEE SIMPLE TITLEHOLDER: ADDRESS: CITY: STATE: ZIP PHONE (DAYTIME): �) CONTRACTOR INFORMATION ST. of FL REGJCERT ##: ST. LUCIE COUNTY CERT ##: BUSINESS NAME: 01 T Ai IF1ERS NAME: ADDRESS: CITY: STATE: - ZIP PHONE (DAYTIME): FAX NO. r email: ARCHIT/BNGINEER: ' ADDRESS: CITY: PHONE (DAYTIME): STATE: ZIP BONDING COMPANY: ADDRESS: . CITY: STATE: ZIP MORTGAGE LENDER: ADDRESS: CITY: STATE: ZIP IMPORTANT NOTICE: Wben a permit is issued and it is not picked up within 60_ dAy. s after notification it will be voided and returned to you by mail. CERTIFICATION: This application is hereby made to obtain a permit to do the work and installations as indicated, and to obtain a certificate of capacity, if applicable, for the permitted work. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction_ I understand that separate permits may be required for ELECTRICAL, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AND AIR CONDITIONERS, ETC., not otherwise included with this building permit application. The -following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures (all -types), swimming pools, fences, walls, signs, screen rooms, utility substations & accessory uses to another non- residential use. NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE TO APPLICANT' AS THE APPLICANT FOR THIS BUILDING. PERMIT, IF IT IS NOT YOUR RIGHT, TITLE, AND INTEREST THAT IS SUBJECT TO ATTACHMENT AS A CONDITION OF THIS PERMIT YOU PROMISE IN GOOD FAITH TO DELIVER A COPY OF THE ATTACHED CONSTRUCTION LIEN LAW NOTICE TO TEE PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT. OWNE 'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in comp] with all applicable laws regulating construction and zoning. SOW EICON CT SIGNATURE CONTRACTOR SIGNATURE STATE OF FLORIDA -9 STATE OF FLORIDA COUNTY OF COUNTY OF The foregoing instrument w4A acknowledged m c The foregoing mstrZent was -acknowledged b re me this a of 20fJ b a x `� y y 3 before me.this �ay of , 20� by PA ho is personally z se � , who is personally y o ". us nown to me who ha roduced 9 n z known to me 6r who has produced as identification. o as identification. aroma 9 ?. r Signature o otary S' ature of Notary Type or Print Na e of Notary Type or Print Name of Notary Commission No.. (Seal) Commission No_ (Seal) NOTE: TWO (2) SIGNATURES ARE REQUIRED. EACH SIGNATURE MUST BE NOTARIZED. IF APPLYING FOR THIS BUILING PERMIT AS AN OWNER/BUILDER, THE OWNER MUST PERSONALLY APPEAR TO SIGN THIS APPLICATION IN -THE OFFICE LISTED ON THE FRONT OF THE APPLICATION. For specific instructions see appropriate permit checklist. St. Lucie Countyo�- 4uilding & Zoning Department C� 2300 Virginia Avenue Fort Pierce, Florida 34982 (772)462-1553 OWNER/BUELDER AFFIDAVIT DISCLOSURE STATEMENT F.S. 489.103 (7) EXEMPTIONS State law requires construction to be done by licensed contractors. You have applied for a pe it,under an exemption to that law. The exemption allows you, as the owner of your property, to act as your own contractor even though you do not have a license. You must provide direct, on -site supervision of the construction yourself. You may build or improve farm outbuildings, a one -family or two-family residence or a commercial building at a cost of under $75,000.00. The building or residence must be for your own occupancy. It may not be built or substantially improved for sale or lease. If you sell or lease a. building you have built or substantially improved your self within one year after the construction is complete, the law will presume that you built or substantially improved it for sale or lease, which is a violation of this exemption. You may not hire an unlicensed person to act as your contractor or to supervise people working on your building; it is your responsibility to make sure that people employed by you have licenses required by state law and by county or municipal licensing ordinances. You may not delegate the responsibility for supervising work to a licensed contractor who is not licensed to perform the work being done. Any person working on your building who is not licensed must work under your direct supervision and must be employed by you, which means that you must deduct F.I.C.A. and withholding tax and provide workers' compensation for that employee, all as prescribed by law. Your construction must comply with all applicable s, ordinances, building codes, and zoning regulations. Initial I understand that the building official and inspectors are not there to design or give advice on how t meet the minimum code. Initial ! - Z I understand that as an owner -builder that any contract disputes with sub -contractors and I must be handled in a civil court with the advice of an attomey. This department will not mitigate any contract disputes. Initial r— S I understand that if I compensate any person or company for work performed they are required to be licensed in this jurisdiction. If for some reason they do not possess a license, I may be responsible and liable] the cost of the license. Initial /�:--� I understand that if any person that is unlicensed and uninsured gets injured on my construction project - they may be entitled to workmen's compensation. I could be held liable for all doctor, lawyer and related --ical cost, which could include loss of wages during recovery from their injury. Initial >� — To qualify for this exemption under this subsection, an owner must personally appear and sign the building permit application and initial the above. I hereby acknowledge that I have read and understand the above disclosure statement and that I further understand that any violation of the terms of the owneribuilder exemption shall be reported by the Building and Zoning Departure to thg Florida St t artment of Professional Regulation.. Si ed and acknowledged on this day of of 20 Owner/Builder Si attire f STATE OF FLO Ct✓� J COUNTY OF The forego' g instrument w acknowledged before me this / : d , 20697 by 451� /0/ /Y-& who is personal own hau or who has produced a Signature of Notary U "Type orpfint Name of Notary Title: Notary Public Commission Number (Seal) ,•'�,11111• AUDREY S. HUMPHREY MY. COMMISSION # DD 633047 EXPIRES: March 6, 2011 9bnt!A 7hru Notary Pubtic Undongdters St. Lucie County Building & Zoning Department 2300 Virginia Avenue ® 50 Y "0 13 Fort Pierce, Florida 34982 (772)462-1553 OWNER/BUILDER AFFIDAVIT DISCLOSURE STATEMENT F.S. 489.103 (7) EXEMPTIONS State law requires construction to be done by licensed contractors. You have applied for a permit.under an exemption to that law. The exemption allows you, as the owner of your property, to act as your own contractor even though you do not have a license. You must provide direct, on -site supervision of the construction yourself. You may build or improve farm outbuildings, a one -family or two-family residence or a commercial building at a cost of under $75,000.00. The building or residence must be for your own occupancy. It may not be built or substantially improved for sale or lease. If you sell or lease a. building you have built or substantially improved your self within one year after the construction is complete, the law will presume that you built or substantially improved it for sale or lease, which is a violation of this exemption. You may not hire an unlicensed person to act as your contractor or to supervise people working on your building; it is your responsibility to make sure that people employed by you have licenses required by state law and by county or municipal licensing ordinances. You may not delegate the responsibility for supervising work to a licensed contractor who is not licensed to perform the work being done. Any person working on your building who is not licensed must work under your direct supervision and must be employed by you, which means that you must deduct F.I.C.A. and withholding tax and provide workers' compensation for that employee, all as prescribed by law. Your construction must comply with all applicab ws, ordinances, building codes, and zoning regulations. Initial 5 I understand that the building official and inspectors are not there to design or give advice on how eet the minimum code. Initial S I understand that as an owner -builder that any contract disputes with sub -contractors and I must be handled in a civil court with the advice of an attorney. This department will not mitigate any contract disputes. Initial I understand that if I compensate any person or company for work performed they are required to be licensed in this jurisdiction. If for some reason they do not possess a license, I may be responsible and liab o the cost of the license. Initial S I understand that if any person that is unlicensed and uninsured gets injured on my construction project - they may be entitled to workmen's compensation. I could be held liable for all doctor, lawyer and related cal cost, which could include loss of wages during recovery from their injury. Initial `J To qualify for this exemption under this subsection, an owner must personally appear and sign the building permit application and initial the above. I hereby acknowledge that I have read and understand the above disclosure statement and that I further understand that any violation of the terms of the owner/builder exemption shall be reported by the Building and Zoning Departm t to the Florida State Department of Professional Regulatio Signed and acknowledged on this _IL_ day of of 209.j�_. 0Wfi&0/9i�uld@SignAur1e 11 STATE OF FLORIDA COUNTY OF �2 J The foe oing mstnime t was acknowledged before me this �� day of , 20 © , by d�i%i� rlu G- who is personally known to me, or who has produced e ��� as identification. Signature o tary Type or Print Name o otary Seal) Title: Notary Public Commission Num pHY p q,....y� AUDREYB, *= MyCOMMISSIO UMPHREY N✓IDD63 P f'' Bonded PIRES. March 6 201 j 647 Thru Notary pu6"O Ur, �,� denvdters Friday, Apr 11, 2008 10:42 AM s ♦ Remove all T-11 Siding except for Gable Ends ♦ Replace all T-11 Siding with 518" Plywood ♦ Make a weather barrier using Felt 30# Atlas ASTM D226 2 S ♦ Replace T-11 Siding (over Plywood and Felt 30#) with Hardie Board to Manufactures specifications and County Codes. On Rear and side of home. ♦ Replace T-11 Siding over Plywood and Felt 30# with Hardie Panel to Manufactures specifications and County Codes. On Front of house only ♦ Have Florida Power and Light remove electrical panel from east side of home and have them replace it when side is done. "girding Code Code Compliance Division Receipt 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 hftp://stiucleco.gov/ce Date: 23 April 2008 Job Address: 7601 DONLON RD Received By: dimonb Paid With: CK Paid By: ROBERT J. SPRING Receipt#: 0000062309 'ermit Number: SLC- 0804-0182 Amount: $230.00 �redit Card Number: Check Number: 3535 Sign: Code Compliance Division 2300 Virginia Avenue Ft Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1148 http://stiucieco.gov/ce Issued: 04/23/2008 Conf #: 700 Job Location: 7601 DONLON RD Permit Type: Building (Miscellaneous) Job Description: BUILDING PERMIT Page 1 Permit #: SLC- 0804-0182 City: FORT PIERCE REMOVE T-11 SIDING AND REPLACE WITH 5/8" PLYWOOD, FELT PAPER AND FINISH WITH HARDI BOARD AND PLANK S/D Lakewood Park Unit 5 Lot: 24 & 25 Block: 43 Parcel: 1301-605-0095-000/6 Property Owner ROBERT J SPRING (772) 465-3888 PO BOX 1953 FORT PIERCE, FL 34954 Setbacks Left: Right: Front: Rear: Zoning: RS-4 Number of Units: 1.00 Floors: 1 Buildings: 1 Square Footage: 0.00 Minimum Floor Elevation: Flood Map: 70F Flood Zone: X Elev: Permit holder acknowledges through acceptance of this permit that separate permits must be obtained as required by the Florida Building Code including those for all electric, plumbing, mechanical, roofing, and structural work. Further, he/she acknowledges responsibility to comply with all requirements of the 2004 Florida Building Code. NOTICE: In addition to the requirements in this permit, there may be additional restrictions applicable to this property that may be found in the records of this County, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. s:553.79(10), F.S. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR BUILDING IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT, s.713.135, F.S. Christopher Lestrange Building Official Date For Automated Inspections, Call (772) 462-1261 For Questions, Call (772) 462-2172 St. Lucie County Land Development Code Section 11.05.01 (A) (2) states; Building Permits shall expire and become null and void if work authorized by such Building Permit is not commenced, having called for and received a satisfactory inspection, within six (6) months from the date of issuance of the permit, or if the work is not completed within 18 months (permit by contractor) or 24 months (permit by owner) from the date of issuance of the Building Permit. WOOD FILE COPY TABLE 2304.9.1—continued FASTENING SCHEDULE CONNECTION FASTENING"" LOCATION 30. Ledger strip 3 - 16d common 4 - 3" x 0.131" nails face nail 4 - 3" 14 gage staples 31. Wood structural panels and particleboard:b Subfloor, roof and wall sheathing (to framing): 1/2" and less 6de,1 2 3/8" x 0.113" nail" 1 3141,16 gage' 15/32 in to 19/32a 8d common (roofs in 6 inch o.o. edges and intermediate. 110-140 mph (Exp. B) 4 inch o.c. at component and 19/32" to 3/4" 8dd or 6de cladding edge strip #3 [refer- Figure 2 3/8" x 0.113" nailp 1609.6.2.2] 2" 16 gageP 8de _.... - 7/8"to 1" -- =— -- -- - Single Floor (combination subfloor-underlayment 1 1/8" to 1 1/4" lOdd or 8de to framing): 3/4' and less 6de 7/8" to l" 8de 1 t/ " to 1 1/ " lOdd or 8de 32. Panel siding (to framing) 1/2" or less 6df 5/ ' 8df 33. Fiberboard sheathing:9 No. 11 gage roofing 1/2" nailh CONCEALED FASTENERS OR ATTACHWM 6d common nail ARE THE RESPONSIBILITY OF THE No. 16 gage staple, u/32" No. 11 gage roofing CONTRACTOR OF WORD nailh 8d common nail _ No. 16 gage staple' 34. Interior paneling 1/4' 4di 3/g" 6dk For SI: 1 inch = 25.4 min. a. Common or box nails are permitted to be used except where otherwise stated. b. Nails spaced at 6 inches on center at edges, 12 inches at intermediate supports except 6 inches at supports where spans are 48 inches or more. For nailing of wood structural panel and particleboard diaphragms and shear walls, refer to Section 2305. Nails for wall sheathing are permitted to be common, box or casing. c. Common or deformed shank. d. Common. e. Deformed shank. f. Corrosion -resistant siding or casing nail. g. Fasteners spaced 3 inches on center at exterior edges and 6 inches on center at intermediate supports. h. Corrosion -resistant roofing nails with'/16 inch -diameter head and 1'/2-inch length for '/Z inch sheathing and 13/4 inch length for 'S/3z inch sheathing. i. Corrosion -resistant staples with nominal'/,6-inch crown and 1 `/e inch length for'/2-inch sheathing and 1 1/2-inch length for 'S/3z inch sheathing. Panel supports at 16 inches (20 inches if strength axis in the long direction of the panel, unless otherwise marled). j. Casing or finish nails spaced 6 inches on panel edges, 12 inches at intermediate. supports. k. Panel supports at 24 inches. Casing or finish nails spaced 6 inches on panel edges, 12 inches at intermediate supports. 1. For roof sheathing applications, 8d nails are the minimum required for wood structural panels. m. Staples shall have a minimum crown width of/16 inch. n. For roof sheathing applications, fasteners spaced 4 inches on center at edges, 8 inches at intermediate supports. o. Fasteners spaced 4 inches on center at edges, 8 inches at intermediate supports for subfloor and wall sheathing and 3 inches on center at edges, 6 inches at interme- diate supports for roof sheathing. * p. Fasteners spaced 4 inches on center at edges, 8 inches at intermediate supports. S'I; LUCIE COUNTY �® BUILDING DIVISI6;f1;;1 THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO 9AmPh' KITH Ili A!''1'WQA44 0990, FOR REVIEWED BY DATE MUST BE 40T ON JOB OR NO INSPECTION WILL BE MADE 23.12R FLORIDA BUILDING CODE — BUILDING A"k ofty iLE uiif)v? F O 1 M 1 A M HDA EE MIAMI-DADE COUNTY, FLORIDA _ METRO-DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE (BCCO) 140 WEST FLAGLER STREET, SUITE 1603 PRODUCT CONTROL DIVISION MIAMI, FLORIDA 33130-1563 (305) 375-2901 FAX (305) 375-2908 NOTICE OF ACCEPTANCE (NOA) James Hardie Building Product, Inc. 10901 Elm Avenue Fontana, CA 92337 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone. DESCRIPTION: Hardiplank, Cemplank, Hardipanel, Cempanel, Hardisoffit and Cemsoffitt APPROVAL DOCUMENT: Drawing No. HPNL-8X, HPLK-4X8 & HSOFFIT-8X, titled "llardipanel & Cempanel; Hardiplank & Cemplank; Hardisoffit & Cemsoffit Installation Details", sheets 1 through 3 with no revisions, prepared, signed and sealed by Ronald Ogawa, PE., dated 04/02/04, bearing the Miami -Dade County Product Control Renewal stamp with the Notice of Acceptance number and expiration date by the Miami Dade County Product Control Division. MISSII.E IMPACT RATING: Large an malt Nfiissile Impact LABELING: Each unit shall bear merman ne b 1 1 the manufacturer's name or logo, city, state and following statement: "Miami Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA # 02-0729.02 and, consists of this page, evidence page as well as approval document mentioned above. The submitted documentation was reviewed by Carlos M. Utrera, P.E. NOA No 07-0418.04 o Expiration Date: May 01, 2012 Approval Date: May 31, 2007 NW Page 1 James Hardie Building Products, Inc. FILE COPY NOTICE OF ACCEPTANCE: EVIDENCE PAGE A DRAWING (submitted under NOA No. 02-0729.02) 1. Drawing prepared by James Hardie Building Products, Inc. titled "Hardipane & Cempanel; Hardiplank & Cemplank; Hardisoffit & Cemsoffit Installation Details", drawing No HPNL-8X, HPLK-4X8 & HSOFFrr-8X, dated 04/02/04, with no revisions, signed and sealed by R. L. Ogana, PE. B TEST (submitted under NOA No. 02-0729.02) Laboratory Report Test Date Signature 1. ATI-16423-1 PA 202 & 203 03/18/96 A. N. Reeves PE. 2. ATI 16423-2 PA 202 & 203 03/18/96 A. N. Reeves PE. 3. ATI 16423-3 PA 202 & 203 03/18/96 A. N. Reeves PE. C QUALITY ASSURANCE 1. Building Code Compliance Office. D MATERIAL CERTIFICATION (submitted under NOA No. 02-0729.02) 1 Standard Compliance (ASTM C-1185) issued by ETL Testing Laboratories on 05/09/95 signed by D. K. Tucker, PE. 2 Evaluation Report NER-405 issued by National Evaluation Service, Inc. on 01/01/93, with no signature. E STATEMENT (submitted under NOA No. 02-0729.02) 1. No change letter issued by James Hardie Building Products, Inc. issued on 02/16/99, signed and by J. L Mulder. 2. Power of Attorney and Appointment of Domestic Representative, signed by P. Shafron on 04117/02, Assignment and Memorandum of Assignment signed by T. P. Dolmans on 04/16/02 and Assignment for the trade marks of Cemplank, Cempanel and Cemsoffit to the Assistant Commissioner for Trademarks signed by V. Lester and P. Shafron on 04/18/02. E OTHERS 1. No change letter issued by James Hardie Building Products, Inc. issued on 04/02/07, signed and sealed by Chad Diercks, Technical Services Manger. 2. Engineer of record letter issued by Ronald Ogawa & Associates, Inc., dated April 3, 2007, signed and sealed by Ronald I.Ogawa, P.E. Carlos M. Utrera, P.E. oduct Control Examiner NOA No 07-0418.04 Expiration Date: May 01, 2012 Approval Date: May 31, 2007 E-1 FILE COPY WALL HEIGHT HARDIPANEL & CEMPANEL SIDING INSTALLATION DETAILS The panels are applied vertically, avoiding horizontal ,Joints, over 5/8' (5 ply) APA rated plywood supported by a minimum of 2'x4' wood studs or 20 ga, x 3 5/8' x 1 3/8' steel studs spaced a maximum of 16' o.c. When Installed on wood studs panels shall be fastened with 6d x 2' lon alvanized box nallsF on steel studs It shall be ns ere wl 8 x 1 5 8' x 0,315' corrosion resistance HAD ribbed bu le screws, e fasteners shall a e p ace o.c, aroun a perimeter of the panel and Intermediate s u s, driven'through e p ywood sheathing Into e studs. opts shall be over studs, Nalls and screws shall have a minimum edge distance of 3/8' and a minimum clearance of 2' from the corners. V'578'`PLYWpOD SHEATHING-SHAL-L---BE-•ATTACHED_TO-THE STUDS IN, ACCORDANCE _TO FLORIDA_BUILDING_CODE,-WITH ANOTHER SET OF (NAILS'OR-SCREWS_AS UNDERLINED ABOVE._ DETAIL A / STUDS (METAL OR WOOD) - DESCRIPTION ' Hardlpanel & Cempanel siding material Is a non asbestos fiber cement Product tested In accordance with ASTM C-1185 and meeting the requirements of the Florida Building Code,, PANEL DIMENSIONS Width Length Thickness r \ 48' 819,10, 5/16' DESIGN PRESSURE RATING Installation Design Pressures Wood frame —76 PSF, Metal frame —104 PSF / NOTES 1) ALL INSTALLATION SHALL BE DONE IN CONFORMANCE WITH THIS NOTICE OF ACCEPTANCE, THE MANUFACTURER'S INSTALLATION RECOMMENDATIONS, AND THE APPLICABLE SECTIONS OF THE FLORIDA BUILDING CODE. 2) STUDS OF METAL OR WOOD WHERE HARDIPANEL & CEMPANEL WILL BE INSTALLED SHALL BE DESIGNED BY AN ENGINEER OR ARCHITECT PER THE F.B.C. AND THE REQUIREMENTS OF THIS N.O.A. SECTION B—B ' PRoleFlcrrseneweo .�u.�ry,,i; er:lA�heFlaxlda A:•n;u N•. .04 Dy_ ASTENER mE, armm�ceaua Divhi HARDIPANEL & CEMPANEL SIDING WATERPROOFING PER 2T T:G:ZA OF F.B.C. /8' PLYWOOD HEATHING PRODUCT RrXISE'D c cor. ;,4�lt:aah OC Flo" Acct£r-:o f • O m i;upifd:.w:� 4raAo Dy Divtdoa JAMES HARDIE FONTS ELM AVENUE / ❑ PRODUCTS — USA FONTANABUILDING 909-356 30 92337 6-427 RESF M & DEVELOPMENT MW FAXi 9 FA%� 909-427-0634 This drawing and the copyright therein are the TE' 04/02/2004 Property of the above company and accordingl the drawing must not he copied or reproduced DRO T: HPNL—BX In any material form whatsoever, ISHELTNa! 1/3 T'LE' HARDIPANEL®& CEMPANEL® scut: NTS FILE COPY .1 WALL HEIGHT HARDIPLANK The planks course of optional P% plate under be over fr used for c 5/8' (5 ply wood studs maximum of lapping plat wood studs H.D, ribbed placed n horiz�ontal�l A d�stnCe 5/8' PLYWOOD SHEATHING SHALL BE ATTACHED TO THE STUDS IN ACCORDANCE TO FLORIDA BUILDING CODE, WITH ANOTHER SET OF NAILS OR SCREWS AS UNDERLINED ABOVE, DESCRIPTION ? Hardiplank & Cemplank siding material Is a non asbestos fiber cement Product tested In accordance with ASTM C-1185 and meeting the requirements of the Florida Building Code, �i \ PLANK DIMENSIQNS Width Length Thickness :59 1/2' 12 & 14' 5/16' DESIGN PRESSURE RATING Installation Design Pressure Wood frame -92 PSF Metal frame . -92 PSF 'I NOTES 1) ALL INSTALLATION SHALL BE DONE IN CONFORMANCE WITH .THIS NOTICE OF ACCEPTANCE, THE MANUFACTURER'S INSTALLATION RECOMMENDATIONS, AND THE APPLICABLE SECTIONS OF THE FLORIDA BUILDING CODE, 2) STUDS OF METAL OR WOOD WHERE HARDIPLANK & CEMPLANK WILL BE INSTALLED SHALL BE DESIGNED BY AN ENGINEER OR ARCHITECT PER THE ' F.B.C. AND THE REQUIREMENTS OF THIS N.O.A. SECTI❑N B-B 5/8' PLYWOOD SHEATHING WATERPR❑❑FING PER 2*fZT.6.Z.X OF -F.B.C. NAIL OR SCREW RDIPLANK CEMPLANK SIDING PRoncri F.N m o cempVer. Wilk the Pladb Hwuu,,P. Co.'e AmpnnceNo 11448.0f Ecpbw$on fe i`Z By radudcoaDW bi a PRODUCT RCV1SM as C=071n'4 wLlb the Florida rA 1 PraAtat Di h[Da DAMES HARDIE* 10901 ELM AVENUE / PRODUCTS — USA FONTANABUILDING 909-356 3 92337 6- REMM & ENT 0E1 M FAX, 9 427 FAX, 909-427-0634 This drawing and the copyright therein are the ATE 04/02/2004 property of the above company and accordingl the drawing must not be copied or reproducer 109 : HPLK-4X8 In any material form whatsoever, ISHELT 0: 2/3 S❑FFIT WIDTH -L It FILE COPY II II II II II II II II II II II II II II II II II II II TRUSSES 16' O.C. HARDISOFFIT & CEMSOFFIT PANEL INSTALLATION DETAILS The soffit panels are to be Installed over minimum 2'x4' wood ,Joists or 20 ga. x 3 5/8' x 1 3/8' steel Joists spaced a maximum of 16' o,c, When Installed on Wood joists Hardlsofflt shall be fastened With 6d x.2' long galvanized box nallsl on steel studs It shall be fastened with #8 x 1 1/4' x 0,315' corrosion resistance H.D. ribbed bugle screws, The fasteners shall be placed 4' o,c, around the perimeter of the panel and Intermediate studs, Nails and screws shall have a minimum edge distance of 3/8' and a minimum clearance of 2' from corners, TRUSSES (METAL OR WOOD) SECTION B-B / DESCRIPTION ��✓ Hardlsofflt & Cemsofflt panels material Is a non,,' asbestos fiber cement product tested ti In accordance with ASTM C-1185 and meeting the requirements of the Florida Building Code, SOFFIT DIMENSIONS Width Length Thickness 548' 8,9,10' 1/4' & 5/16' DESIGN PRESSURE RATING 1' qj`/�, Installation Design Pressure 1"" 1 ' Wood frame t53 PSF Metal frame t 53 PSF NOTES 1) ALL INSTALLATION SHALL BE DONE IN CONFORMANCE WITH THIS NOTICE OF ACCEPTANCE, THE MANUFACTURER'S INSTALLATION RECOMMENDATIONS, AND THE APPLICABLE SECTIONS OF THE FLORIDA BUILDING CODE. 2) TRUSS OF METAL OR WOOD WHERE HARDISOFFIT & CEMSOFFIT WILL BE INSTALLED SHALL BE DESIGNED BY AN DETAIL A ENGINEER OR ARCHITECT PER THE F,B,C, AND THE REQUIREMENTS OF THIS N.O.A. PRODUCPRENEWED m mmp,y{nq wdb Ibe PMW A!tcpaacc Nn Es{rd•al;a a7o / Q ' By Mia WeProd�A Coafevl DNIe a HARDISOFFIT & CEMS❑FFIT PANEL FASTENER PRODUCT REVISED a.."V;y*g wild The Floridk 0ck:,; crag: - -- JAMES HARDIE 10901 ELM AVENUE BUILDING PRODUCTS — USA 92337 FO-35 DEV,,,Uw :E . 30 909-356-6300 FAX, 909-427-0634 This drawing and the copyright therein are tha WE' 04/02/2004 property of the above company and according,y the drawing nust not ba copied or reproduced 0R0 0: HSOFFIT-BX In any material form Nhatsoever. ISHMNa.- 'i/C & CEMSOFFIT® i III James Hardie: Hurricane Resist Technical FAQ Page 1 of 4 H-jamesHardie Hurricane Resistance - Technical FAQ Read answers to frequently asked questions about hurricane resistance. The Technical FAO section contains excerpts from the papertitled: USE OF FIBER -CEMENT IN DISASTER RELIEF HOUSING IN THE US by Basil Naji, published in the proceedings of the World Housing Congress, held in Terengganu, Malaysia, 1-5 July 2007. What kind of winds do James Hardie products withstand? Hurricanes (or Tropical Cyclones) cause damage and destruction from high winds, river flooding that results from intense precipitation, and storm surges (wind -driven oceanic waters). The wind speeds of historical hurricanes in the US between 1886 and 1996 are shown in the map below (figure 6). The higher risk counties along the Gulf and Eastern seaboard are clearly shown. % � Slates CowdyBormdaie< Hnrri�rnc Zorics Lzt,"e� r�_yg �li 60 - ,a nipb 7;.*mph � �•=90urrr6 iow ;cm ne. Cop)nitigh. )991 EDgeTeeb A—ft., hi, Figure 6: Hurricane Winds (1886—1996), (Source: National Hurricane Center - Atlantic and Western Pacific Databases) The property damage from hurricanes can be staggering. It can cause damage to roofing material, bulking doors and windows, and considerable damage to mobile homes. Due to its impact resistance against hail and windblown debris, fiber -cement siding has been specified by hurricane -zone building codes for building homes in hurricane-, tornado-, and wildfire -prone areas [6) (figure 7). It can withstand hurricane forces winds up to 150 mph (3-second gust) provided the installation conforms to proper installation methods found within the NERA05 or Miami -Dade County Florida NOA 07- 0418.04 [7) (figure 8). What hurricane -resistant codes do James Hardie products meet? James Hardie siding products are deemed a FEMA Class V flood resistant material (JHBP FEMA Class V) and are approved for use in Wind Borne Debris Regions and High Velocity Hurricane Zones (Miami=Dade NOA 07-0418_04). h4://Yiww.jameshardie.com/homeowner/hurricanc�_faq.shtml 4/7/2008 James Hardie: Hurricane Resist), Technical FAQ - Page 2 of 4 [ Cm noaro. nlw.� - Leerol .He.me W� aM)1W+� M 1*0*0d,' (dnpp�i; fnat..� 1 _ FEMA Drawing ifi® Itn MGtablfmwavcurnnllinX I��UIILaCIItnpQr.H[Irin1 I.mr�.4,nnar.m. � ,xwl lui+nrr�;�n LrII.d. YI1.sM�41.r. aaral /F4.wr Nw�.0 Win' il'nlattkhyim:i mdungi4atkrai. oJ�l4lwt [nrnr{Mw <INac+avamms. Im.+wu. WeYe..evm,ce.a1A Mm[IWaR.ur, I.W iGwT. n-6i,w W.+rT-1 NRuer LutKvmaGVUL ibet4t N.i Y. t..afe c4r ee eQ:zia.Su old lN.. ae N�YN OYL C.wr) fI4C4Y l'aW� ti.mnll,K ''OYcC w)1>dn Pe.VUli,ecn.Ve lr�V,wl>w l'wer�)n.x Sa.iihm e�Mrd.iuumJrsi 4 yutq evun>.ry�r Ira4r4w...r.JLi M RirSMf. CatHf.Oa pp,iw-yc r,u nA b npe.. n iv twy W oe tiU Hri wsvYry Hnln4a.4 H41n4 tKaiNti Ma%:..`w. r ic.[a 1.1..Hmt Yyae.Jw,Ldbs4raWOy Figure 7: Fiber -cement siding is specified by building codes for use in hurricane -zone housing [6]. Figure 8: fiber -cement sided house in Jackson County, Mississippi which survived Hurricane Katrina. What strength were the winds for Hurricane Katrina? Hurricane Katrina was one of the strongest storms to impact the coast of the United States during the past 100 years. It was the most destructive and expensive natural disaster in the history of the United States, with estimated total economic losses in excess of $125 billion and insured losses of $35 billion [8]. On August 25, 2005, the storm made its first landfall on the southeast coast of Florida as a Category 1 hurricane. It then crossed south Florida and moved into the Gulf of Mexico, where it gained strength to a Category 5 hurricane, although it weakened before making its second landfall. According to the National Climatic Data Center (NCDC), Hurricane Katrina made its second landfall on August 29, 2005 as a strong Category 3 storm in southeast Louisiana near Buras, with 1-minute sustained winds estimated at 127 miles per hour (mph). After coming ashore in Louisiana, Katrina continued to move northeastward across Breton Sound, to make a third landfall near Peadington, Mississippi, as a Category 3 storm with sustained wind speeds estimated at approximately 120 mph or approximately 145 mph 3-second gust (figure 9). The storm surge caused failures of the levee system that protects New Orleans from Lake Pontchartrain, and subsequently an estimated 80 percent of the city was flooded [8]. Destruction on that scale has created a housing emergency likely to last for years, with demand outstripping the capacity of conventional construction techniques [9]. http://www.jameshardie.com/homeowner/hurricane—faq.shtml 4/7/2008 James Hardie: Hurricane Resiw.-b-�� Technical FAQ 1 Page 3 of 4 Figure 9: A map of Hurricane Katrina's movement Why does the Katrina Cottage have James Hardie siding? Katrina Cottage 1 is constructed with wood or steel framing and finished with fiber cement siding and a metal roof. The cottage is designed to withstand heavy rain and winds up to 140 miles per hour (3-second gust) (figure 11). It is estimated that the 308 sf model can be delivered for about $70,000 per unit [13]. Figure 11: Katrina Cottage 11131 Katrina Cottage 11 is a 770-square-foot, two bedroom model in the architectural traditions of South Louisiana. The cottage is designed to take advantage of the latest approaches in panelized construction techniques, and could eventually be expanded into a full-size permanent home. At 16 by 30 feet, it has 480 square feet on the first floor and a 300-square-foot loft above. The structure can be built and delivered within three weeks for approximately $70,000 - $80,000 [9]. The construction technique uses foam -insulated panels prefabricated by a Florida company, Home Front, specializing in panelized construction that is hurricane -resistant, energy -efficient and environmentally sustainable (figure 12). The Katrina cottage is built like a "sandwich": outer structural panels of fiber -cement board and an inner core of polystyrene foam. The cottages have been lab -tested to withstand 200-miles per hour winds [141. Figure 12: Katrina Cottage 11 [13, 14J http://wwwjameshardie.com/homeowner/hurricane�__faq.shtmi 4/7/2008 James Hardie: Hurricane Resisi� --it Technical FAQ Page 4 of 4 James H ardie's commitment fo a better understanding of building systems and rp actices ( video ] Copyright 2008 James Hardie International Contact Us I Terms & Conditions I Privacy Policy I Careers Finance B.V. http://www.jameshardie.com/homeowner/hurricanc�_faq.shtnl 4/7/2008 1 HARDISOFF/T INSTALLATION INSTRUCTIONS James Hardie® JANUARY 2003 IMPORTANT. FAILURE TO INSTALL AND FINISH HARDISOFFITO PANELS IN ACCORDANCE WITH APPLICABLE BUILDING CODE COMPLIANCE REPORTS ANOD JAMES HARDIE'S WRITTEN APPLICATION INSTRUCTIONS, MAY AFFECT SYSTEM PERFORMANCE, VIOLATE LOCAL BUILDING CODES REQUIREMENTS, AND VOID THE PRODUCT ONLY WARRANTY. HANDLING & STORAGE: CUTTING OPTIONS - Store Hardisoffit panels flat on a smooth level surface, under cover. If panels have become saturated, allow to dry prior to Circular saw with Circular saw blade Electric or pneumatic Carbide score and installation. dust collector with carbide-ti ed teeth hand shear snap knife . Protect edges \ `pGNIZfpF PP P and comers A JH recommends Makita®#5044KB 4" or #5057KB 7-1/4" saw with dust collection. Call 8004MAKITA 4; �;,;6e A Hitachi® HARDIBLADETm w/4 PCD Diamond Teeth. Call Hitachi® at 800-546-1666 for nearest dealer. from breakage. of Wt� A SNAPPER SHEARTM electric or pneumatic hand shear. Call 800-297-7487 for tool information. . Always wear safety glasses and dust protection when operating power tools. For more information on avoiding inhalation refer to the MATERIAL SAFETY DATA SHEET available wherever James Hardie fiber�cement products are sold. BASIC COMPOSITION AND SIZE Portland cement, ground sand, cellulose fiber, select additives and water. Hardisoffit panels contain no asbestos fibers, glass fibers, or formaldehyde. Hardisoffit panels are dimensionally stable and will not crack, rot, or delaminate. Hardisoffit fiber -cement. panels resist damage caused by extended exposure to moisture, humidity and salt air. Hardisoffit panels have been evaluated in accordance with ASTM Method E 136, and may be installed where noncombustable construction is required. Textures: Smooth & Select Cedarmill Sizes: Non -vented: 12" x 144", 16" x 144", 24" x 144", 48" x 96" Thickness: 1/4" Vented: 12" x 144", 16" x 144", 24" x 144" FRAMING REQUIREMENTS: Hardisoffit panels may be installed over either metal or wood Apply soffit panels to nominal 2 x 4 framing members spaced a maximum of 24 framing members complying with the local Building Code, inches on center, with the long dimension perpendicular to the framing. Fast - including the use of weather- resistive barriers where required. eners are installed 3/8" from the edge of the board and 2" in from the comers. SOFFIT USES figure 1 \ venting shim fascia (wood) Hardisoffit subfascia vented panel HardiplankO JOINING METHODS siding Hardisoffit panels are fastened at abutting framing board edges, and member optionally covered by figure 4 PVC or metal joiners, battens, or with an PVC H-molding acrylic caulk. (figure 4) figure 2 / \ Hardisoffit' fascia non -vented (wood) panel subfascia figure 3 venting strip i \ hardisoffit- ` / panel fascia (wood) subfascia frieze board 2" x 4" nailer for brick frieze 2" x 4" nailer for brick frieze WARNING: AVOID BREATHING SILICA DUST Product contains Silica. Inhalation of respirable silica dust can cause silicosis a potentially disabling lung disease, and is known to the State of California to cause lung cancer. When drilling, cutting, or abrading product during installation or handling: (1) Work outdoors where feasible, otherwise use mechanical ventilation, (2) Wear a dust mask or, if dust may exceed PEL, use.NIOSH/MSHA approved respirator, (3) Warn others in area. For further information, refer to material safety data sheet or consult employer. FAILURE TO ADHERE TO WARNINGS, MSDS, AND INSTALLATION INSTRUCTIONS MAY LEAD TO SERIOUS PERSONAL INJURY. APPROVALS: HARDIRANELS Vertical Siding is recognized as an exterior wall cladding In No tonal Evalualion Report No. NER405 (BOCA, ICBO, SBCQ: City of Los Angeles, a JamesHardie'ssealofapprovalindicates Research Report No.24882; Metro -Dade County, Florida, Acceptance No. 99-0223.07, US Dept of HUD Materials Release 1263a, Califomia DSAPA-019 and City of New products recommended for use by YorkMEA223-93M.Those documents should also be consulted for additionalinformallonconcerningthesuitabltyofthisproductforspecificapplip8ons. James Hardie Building Products ATTENTION: BUILDER/ARCHITECT GENERAL INFORMATION: IMPORTANT: These instructions are to be used for the application of Hardisoffit,paneis on conventional, site built wood and metal frame buildings. For other applications, such as those, for factory -built , construction (including manufactured housing, modular or panelized buildings) please contact James Hardie Building Products 1-(800)-9HARDIE (942-7343). WORKING WITH VENTED HARDISOFFIT PANELS: Hardisoffit panels must be fastened to a solid, nailable substrate (e.g. a wooden 2 x 4 subfascia), not into.another Hardie product. Position the vented section of the Hardisoffit panel towards the outside of the eave for optimal airflow. VENT PERFORMANCE: Continuous ventilation systems provide the most efficient mode of air intake possible. Hardie's vented soffit products provide 5.0 square inches of net free ventilation per linear foot of soffit. JOINING REQUIREMENTS Hardisoffit panels are fastened at abutting board edges and optionally covered by PVC or metal joiners, battens, or with a compatible caulk (see Finishing Hardisoffit). FASTENER SIZE AND SPACING • Installation. to.conventional wood frame construction in most locations: minimum 4d common nails spaced 8" o.c: at panel edges and intermediate framing members spaced.up to 24 on center. • Installation to conventional 20ga metal frame construction in most locations: minimum No. 8-18 x 0.323" HD x 1" long Hi-Lo® S® or S-12TM ribbed bugle screws spaced 6" o.c. at panel edges and intermediate framing members spaced up to 24" on center. • Minimum Basic Wind Speed differs,by locality: Where specified levels of.wind resistance are required, refer to Building Code Compliance Reports (Approvals). - FASTENING: Hardisoffit panels can be hand nailed or fastened with a pneumatic tool. Set your air pressure so that the fastener is. driven -snug with the panel surface. The use -of a flush mount attachment is recommened on pneumatic tools to help control the depth that the nail is driven. This will be especially useful when more than one tool is driven off the same compressor. FASTENER REQUIREMENTS: • Position fasteners a minimum of 2" from soffit corners and 3/8"f6m edges. • Drive fasteners perpendicular to siding and framing.. • Fastener heads should fit snug against. soffit (no air space). (Fig. A & B) . . DO NOT • Do not over -drive nail heads or drive nails atan angle. STAPLE • If nail is countersunk; caulk nail hole and add a. nail. (Fig. C) Countersunk, Snug Flush Caulk & add nail Fig.A Fig. B Fi C do not under 9 9 drive nails FASTENERS: Nails and screws must be corrosion -resistant. Nails complying with ASTM F-1667, must be corrosion -resistant, galvanized, or stainless steel. Electro-galvanized nails may be used, but may exhibit premature corrosion. James Hardie recommends the use of quality, hot -dipped galvanized nails. Screw fasteners for the installation of Hardisoffit shall be corrosion -resistant. FINISHING HARDISOFFIT: Caulking: Painting: A high quality, paintable caulk is recom- James Hardie soffit products must be.painted. For best Patching: mended. For best results use caulks results use Hardisoffit panels with our exclusive Prime Dents and chips can be that comply with either.ASTh1 C 834 or PlusTm factory priming system and 100% acrylic topcoat filled with a cementltlous ASTM C 920. Caulking should be applied (s). * If our Prime Plus"A factory priming is not being used, in accordance with caulking manufacturers Hardie recommends the application of an alkali -resistant patching written instructions. (Leave 1/8" gap at trim primer along with 100% acrylic topcoat (s). (For paint compound. for caulk. Caulking atbutt joints is optional.) manufacturer's paint specifications, refer to JH Technical Bulletin~ CEMENT No.S-100.) *Note: Please refer to paint goo^/o PATCH manufacturers' s ecifications for ACRYLIC ,caUK �/'�'� P PAINT application rates.. Corporate Headquarters James Hardie® 26300 La Alameda, Suite 250, Mission Viejo, CA 92691 ©2003 James Hardie Building Products, Inc: Printed in the U.S.A. TM, O, and © denote trademarks and copyrights owned by Bul Hiding Products James Hardie Research Pty Limited ACN 066 114 092. Printed in USA For Technical Assistance, MSDS, Approved by Lowes and Product Information .Call 1-800-9HARDIE11111111 (1-800-942-7343) www.jameshardie.corri Improving Home Improvement BM2121602 JH2O58DIY 1/03 © 2003 by Lowe'se. All rights reserved. Lowe's and the gable design are registered trademarks of LF Corporation. VERTICAL SIDING -INS,. rLLATION INSTRUCTIONS HARDPANLL FOR WOOD FRAMING JANUARY 1998 SMOOTH * CEDARMILLTM * SIERRA 4" * SIERRA 8" * STUCCO IMPORTANT: FAILURE TO INSTALL AND FINISH HARDIPANELO PER JAMES HARDIE'S WRITTEN INSTRUCTIONS MAY AFFECT PRODUCT PERFORMANCE AND WILL VOID THE WARRANTY. LOCAL BUILDING CODE REQUIREMENTS ALSO APPLY. HANDLING & STORAGE: CUTTING OPTIONS: Store flat and keep dry prior to installation. Cary panels on edge. UO n Circular saw with "SNAPPER STEEL HEADTMI) "WINDSHEARTM11 Score and snap carbide tipped blades Electric Hand Shear Pneumatic Shear knife Call 800-297-6487 for shear tool information. Always wear safety glasses and dust protection when operating power tools. For more information on avoiding inhalation refer to the MATERIAL SAFETY DATA SHEET available wherever James Hardies' fiber -cement products are sold. FRAMING REQUIREMENTS: Figure #1 Hardipanel vertical siding can be installed to studs spaced a maximum of 24" o.c. Irregularities in framing can mirror through the finished application. A weather -resistive barrier is required. Applying Hardipanel Siding: • Start Hardipanel vertical siding at middle of stud. • Keep nails 2" away from corners. • Start at edge and work across. • Follow caulk and paint requirements. Weather -Resistive Stud Barrier * -� Hardipanel siding Keep nails 0 0 3/8" min. from panel edges 0 0 Plate 318" o 0 Space panel according to Keep fasteners 2" point treatment away from corners max.1/16" gap * Use a weather -resistive barrier in accordance with: BOCA National Building Code Section 1403.3; SBCCI Standard Building Code Section 2303.3; ICBO Uniform Building Code Section 1402.1; or CABO One -and Two -Family Dwelling Code Section 703.2.1. NOTE: Many Building Codes exempt the use of weather -resistive barriers over "water-repellent sheathing" or exterior panels classified as "weather -resistive barriers". However, in most cases where a weather -resistive barrier is not used, wind driven rain and snow may penetrate the unprotected wall cavity. Therefore James Hardie recommends the use of "building paper type" weather - resistive barriers with all siding products. (James Hardie will assume no responsibility for moisture within the wall) JOINT DETAIL Figure #2 • Keep fasteners 3/8" back from panel edges. • Place fasteners 2" in from all corners; don't nail into corners. • Joints may also be covered with lumber batten, PVC "H" or "T" type joint treatment. • When caulking vertical panel joints, space panels accordingly to caulking manufacturers required bead size. • Horizontal Joints - use "Z-Bar" or similar type flashing for all horizontal joints. GaulK Joint 2 x 4 stud IN weather -resistive barrier* Hardipanel Batten Joint 2x4stud Figure #3 Suggestion: Using a double stud at panel joints will allow forfastener placement to be out of panel grooves (Sierra 4" & 8") for improved appearance. GRADE CLEARANCE Figure 4 Building Codes require a minimum of 6" clear- ance between bottom edge of panel/framing and earth or finished landscaping. Hardipanel Stud Siding Weather - Resistive i Barrier*'-,i Plate - °° ° J 6' c� Concrete I Foundation Hardie Siding applied above porches, patios, driveways, etc. must have a 2" clearance which will allow the siding to remain above the surface where water might collect. ROOF CLEARANCE Figure 5 Leave 2" clearance between roofing and bottom edge of siding. -a. 114 R, PNEUMATIC FASTENING: Hardipanel vertical siding can be hand nailed or fastened with the use of a pneumatic tool. Set your air pressure so that the fastener is driven snug with the panel surface. (0 RECOMMENDED: Use a flush mount attachment on pneumatic tool. This will help control the depth that the nail is driven. This will be especially helpful when more than one pneumatic tool is driven off the same compressor. NAIL TYPE: z' __)NCRETE CONSTRUCTION Figure 6 When Hardipanel vertical siding is installed over concrete construction, the wall must be furred out with nominal 2 x 2 lumber. Framing can be spaced up to 24" o.c. A weather -resistive barrier is recom- mended between the framing and siding. Weather -Resistive Barrier, FASTENER REQUIREMENTS: Nominal 2"x2" Wood Framing --L • Drive fasteners perpendicular to siding and framing. • Fastener heads should fit snug against siding. (Fig. A) • Do not overdrive nail heads or drive nails at an angle. • If nail is countersunk, caulk nail hole and add a nail. (Fig B & C) Caulk & Snug Counter Sunk add nail Fig. A Fig. B Fig. C Fasteners must be corrosion resistant, Galvanized or Stainless Steel. Electro-galvanized nails are acceptable for use with James Hardie Siding Products, but may exhibit premature corrosion. We recommend the use of quality, hot -dipped galvanized nails, such as the Maze® brand or that of an equivalent brand. (James Hardie is not responsible for the corrosion resistance of fasteners.) Fastener Spacing (inches) 6" edge 12" field 6" edge 6" field 4" edge 4" field 6" edge 12" field 6" edge 6" field SHEAR AND WIND LOAD FASTENING SCHEDULE 5/16" THICK HARDIPANEL VERTICAL SIDING ONLY Stud Shear Spacing Value (inches) (PLF) 16" OC 157 16" OC 200 16" OC 16" OC 233 24" OC 145 24" OC 153 Bldg. Maximum Basic Wind Height Speed Zones B C 40' 120 90 20' 40' 20' 40' 20' 40' 20' 40' 120 120 120 120 120 120 110 110 100 90 100 100 190 90 80 80 4" edge 24" OC 212 20' 120 105 4" field 40' 120 95 Frame type: 2 x / .42 Specific Gravity minimum. Fastener: 6d Common - corrosion resistant.Table for reference only. For information on steel framing and other Hardipanel applications refer to James Hardie National Evaluation Service NER405 or call 1.800-9-HARDIE. FINISHING HARDIPANEL: Patching: Dents, chips and cracks can be filled with a cementitious patching compound. Caulking: A high quality, paintable latex caulk is recom- mended. For best results use a latex caulk that complies with ASTM Specification C 834. Caulking should be applied in accordance with the caulking manufacturer's written application instruc- tions. (Leave 1/8" gap at trim for caulk. Caulking at abutting panel joints is optional.) Painting: For best results use Hardipanel sidings with our exclusive Prime PIUSTM factory approved 100% acrylic topcoat(s).** If our Prime PIUSTM factory priming is not being used, Hardie recommends the application of an alkaline resistant primer along with 100% acrylic topcoat (s). (For paint manufacturers paint specifications, refer to JH Technical Bulletin No. S-100.) **Note: Please refer to paint manufacturer's specifications for application rates. APPROVALS: HARDIPANELTM Vertical Siding is recognized as an exterior wall cladding in National Evaluation Report No. NER-405 (BOCA, ICBO, SBCC): City of Los Angeles, Research Report No. 24882; Metro -Dade County, Florida, Acceptance No. 94-1234.04, US Dept. of HUD Materials Release 1263a, California DSA PA-019 and City of New York MEA 223-93M. These documents should also be consulted for additional information concerning the suitability of this product for specific applications. For Technical assistance call 1.800-9-HARDIE. Always wear safety glasses and dust protection when operating power tools. For information on avoiding dust inhalation, refer to the MATERIAL SAFETY DATA SHEET available wherever James Hardie fiber -cement products are sold. ©1998 James Hardie Building Products Corporate Headquarters 26300 La Alameda, Suite 250 Mission Viejo, CA 92691 ©1998 James Hardie Building Products Printed in USA For Technical Assistance Call 1-800-9-HARDIE www.jameshardle.com James Hardie TM JH1116SL Hardiplank'5 Lap Siding INSTALLATION INSTRUCTIONS James Hardie® Building Products NOVEMBER 2004 SELECT CEDARMILL© • SMOOTH • COLONIAL SMOOTH® • COLONIAL ROUGHSAWN® BEADED CEDARMILL • BEADED SMOOTH IMPORTANT: FAILURE TO INSTALL AND FINISH THIS PRODUCT IN ACCORDANCE WITH APPLICABLE BUILDING CODES AND JAMES HARDIE'S WRITTEN APPLICATION INSTRUCTIONS MAY AFFECT SYSTEM PERFORMANCE, VIOLATE LOCAL BUILDING CODES, AND VOID THE PRODUCT ONLY WARRANTY. HANDLING & STORAGE: Store flat and keep dry prior to installation. Installing siding wet or saturated may result in shrinkage at butt joints. 1i � Carry planks on edge. © RECOMMENDED CUTTING INSTRUCTIONS OUTDOORS INDOORS 1. Position cutting station so that wind will blow dust away from user or 1. Position cutting station in well -ventilated area; otherwise, additional others in work area. mechanical ventilation (e.g. box fan, HEPA vacuum, etc.) is required 2. Use one of the following methods based on the required cutting rate: 2. Cut only using score and snap, or shears (manual, electric or pneumatic). a. Best: i. Score and snap ii. Shears (Pneumatic or Handheld) - NEVER use a power saw indoors b. Better: i. Dust reducing circular saw equipped with NEVER use a circular saw blade that does not carry the Hardiblade logo Hardiblade and HEPA vacuum extraction NEVER dry sweep c. Good: i. Dust reducing circular saw with Hardiblade Additional exposure information is available at www.jameshardie.com to help you determine the most appropriate cutting method for your job requirements. If concern still exists about exposure levels or protection levels, you should always consult a qualified industrial hygienist. FRAMING REQUIREMENTS: Hardiplank® lap siding can be installed over braced wood or steel studs spaced a maximum of 24" o.c. or directly to minimum 7/16" thick OSB sheathing. Hardiplank lap siding can also be installed over foam insulation up to 1" thick.t Irregularities in framing, sheathing, and/or foam insulation can mirror through the finished application. The use of a Weather -resistive barrier is required in frame construction with siding. James Hardie recommends the use of asphalt saturated felt or equivalent non -woven, non -perforated, vapor permeable building paper or housewrap. Note: James Hardie does not recommend the use of water repellant wood based panel sheathing as the primary weather resistive barrier. The weather resistive barrier must be appropriately incorporated with penetration and junction flashings. Materials must be lapped such that water will drain down and to the outside. James Hardie will assume no responsibilty for water infiltration within the wall. The first course of any wall should be installed over a 1/4" lath strip to ensure a consistent plank angle (see figure 1). Blind nailing Hardiplank stud V from weather -resistive plank top barrier rl�L I figure 1 Double Wall Single Wall Construction Construction weather -resistive barrier let -in bracing plywood or 24" D.C. max. OSB sheathing 1T from \ ° plank edge ° ° leave appropriate gap between plank and trim, then caulk* ' Space plank according to joint treatment either in * moderate contact "moderate contact" ljoints not caulked) or in accordance with the caulking manufacturer's written application instructions (joints caulked), see detail at right. t For application over foam insulation, the length of the specified fastener shall be increased by the thickness of the foam insulation. GRADE CLEARANCE figure 2 Install Hardiplank® lap siding in compl- iance with local building code require- ments for clearance between the bottom edge of plank and the adjacent finished grade (see Important Note). weather -resistive stud barrier concrete foundation i_r— 1/4" thick'rL-�", , Han lath strip \ ` lap IMPORTANT NOTE ROOF CLEARANCE figure 3 At the juncture of the roof and vertical sur- faces, flashing and counterflashing shall be provided per the roofing manufacturer's Instructions. Provide a minimum of a 2" clearance between the roofing and bottom edge of siding. tiashing 9„ ° barrier ° fastener ° 1/4" thick lath strip CONCRETE CONSTRUCTION figure 4 Hardiplank lap siding can be installed directly to masonry block. Hardiplank siding can aslo be installed to concrete construction when the wall is furred out with wood framing or minimum No. 20 gauge steel framing anchored to the wall. Framing can be spaced up to 24" OC. Consult applicable code compliance report for recognized application to masonry block. Aweather-resistive barrier is recommended between the framing and the siding. weather - resistive barrier —,­t, tal • Install James Hardie® products with a minimum 6" clearance to the earth on the exterior of the building or in accordance with local building codes if greater than 6" is required. • Maintain a minimum 2" clearance between James Hardie® products and roofs, decks, paths, steps and driveways. • Adjacent finished grade must slope away from the building in accordance with local building codes - typically a minimum of 6" in the first 10'. • Do not install Hardiplank® lap siding, such that it may remain in contact with standing water. WARNING: AVOID BREATHING SILICA DUST James Hardie products contain respirable crystalline silica which is known to the State of California to cause cancer. Inhalation of respirable silica can cause silicosis (a disabling lung disease), lung cancer, and has been linked, therefore, to death. When drilling, cutting, sanding, or grinding products during installation or handling: (1) Work outdoors where feasible, (2) Wear a dust mask, or use a NIOSHIMSHA approved respirator whenever US OSHA PEL is exceeded or as required by applicable law, (3) Wam others in area, (4) During clean-up, never dry sweep. According to some medical experts, and the US Surgeon General, cigarette smoking can significantly increase your likelihood of contracting lung -related diseases, including silica -related lung diseases. For further information, refer to our installation instructions and Material Safety Data Sheet available at www.jameshardie.com or by calling 1-800-9HARDIE. FAILURE TO ADHERE TO OUR WARNINGS, MSDS, AND INSTALLATION INSTRUCTIONS MAY LEAD TO SERIOUS PERSONAL INJURY OR DEATH. FACE NAIL: (All Lap Products) *" figure 5 BLIND NAIL:** figure 6 * Corrosion Resistant Nails (galvanized or stainless steel) • 6d (0.113"shank x 0.267" HD x 2" long) • Siding nail (0.089" shank x 0.221" HD x 1-1/4" long) • Siding nail (0.091" shank x 0.221" HD x 1-1/2" long) $ Corrosion Resistant Screws • Ribbed Wafer -head or equivalent (No. 8-18 x 0.323" HD x 1-5/8" long) Screws must penetrate 1/4"or 3 threads into metal framing. Corrosion Resistant Fasteners • ET & F pin (0.100" shank x 0.25" HD x 1-1/2" long) _ 24" — o.c. max. 1 1/4" min. overlap * moderate contact 3/4I"-1" Ii — °° face nail • Corrosion Resistant Nails (galvanized or stainless" steel) • Siding nail (0.089" shank x 0.221" HD x 2" long) • 11 ga. roofing nail (0.121" shank x 0.371" HD x 1-1/4" long) Corrosion Resistant Screws • Ribbed Wafer -head or equivalent (No. 8-18 x 0.323" HD x 1-5/8" long) Screws must penetrate 1/4" or 3 threads into metal framing. Corrosion Resistant Fasteners • ET & F PanelfastTM (0.100" shank x 0.313" HD x 1-1/2" long) Minimum overlap for Both Face and Blind Nailing weather -resistive min. 1 1/4" barrier overlap 1 1/4" min. } overlap t When face nailing to OSB, planks must be no greater than 91/2" wide and fasteners must be 12" o.c. or less. ** See Fastening Requirements. FASTENING REQUIREMENTS: Fasteners must be corrosion resistant, galvanized, or stainless steel. Electro-galvanized are acceptable may exhibit premature corrosion. James Hardie® recommends the use of quality, hot -dipped galvanized nails. James Hardie is not responsible for the corrosion resistance of fasteners. Stainless steel fasteners are recommended when installing James Hardie products near the ocean, large bodies of water, or in very humid climates. Do not use aluminum fasteners, staples, or clipped head nails. DO NOT STAPLE barrier * moderate contact • Consult applicable code compliance report for correct fasteners type and placement to achieve specified design wind loads and shear values. • NOTE: Published shear values and wind loads may not be applicable to all areas where Local Building Codes have specific jurisdiction. Consult James Hardie Technical Services if you are unsure of applicable Building Code jurisdiction. • Drive fasteners perpendicular to siding and framing. • Fastener heads should fit snug against siding (no air space). (Fig. A & B) • Do not over -drive nail heads or drive nails at an angle. • If nail is countersunk, caulk nail hole and add a nail. (Fig. C) • Under driven nails should be hit flush to the plank with a hammer. Hardiplank® lap siding products can be hand nailed or fastened with a pneumatic tool. Pneumatic fastening is highly recommended. Set air pressure so that the fastener is driven snug with the surface of the siding. A flush mount attachment on the pneumatic tool is recommended. This will help control the depth the nail is driven. If setting the nail depth proves difficult, choose a setting that under drives the nail. Hit the under driven nails snug with a smooth faced hammer. Do not over drive nails into Hardiplank® lap siding. Snug ® figure A Flush figure B Countersunk, Caulk & add nail do not under figure C drive nails COVERAGE CHART/ESTIMATING GUIDE 1. Figures shown are in pieces - all 12 long 2. 5% cutting and fitting waste factor included 3. Computations based on minimum overlap of 1-1/4 4. Actual usage subject to variables such as building design and installers Hardiplank® Siding Width Coverage Area 5-1/4" 6-1/4" 7-1/4" 7-1/2" 8" 8-1/4" 9-1/4" 9-1/2" 12" Less Openings (exposure) (4) (5) (6) (6-1/4) (6-3/4) (7) (8) (8-1/4) (10-3/4) 100 sf 1 SQ 26 21 18 17 16 15 13 13 10 200 sf 2 SQ 53 42 35 34 31 30 26 25 20 300 sf 3 SQ 79 63 53 50 47 45 39 38 29 400 sf 4 SQ 105 84 70 67 62 60 53 51 39 500 sf 5 SQ 131 105 88 84 78 75 66 64 49 600 sf 6 SQ 158 126 105 101 93 90 79 76 59 700 sf 7 SQ 184 147 123 118 109 108 92 89 68 800 sf 8 SQ 210 168 140 134 124 120 .105 102 78 900 sf 9 SQ 236 189 158 151 140 135 118 115 88 1000 sf 10 SQ 263 210 175 168 156 150 131 127 98 1100 sf 11 SQ 289 231 193 185 171 165 144 140 107 1200 sf 12 SQ 315 252 210 202 187 180 158 153 117 1300 sf 13 SQ 341 273 228 218 202 195 171 165 127 1400 sf 14 SQ 368 294 245 235 218 210 184 178 137 1500 sf 15 SQ 394 315 263 252 233 225 197 191 147 1600 sf 16 SQ 420 336 280 269 249 240 210 204 156 1700 sf 17 SQ 446 357 298 286 264 255 223 216 166 1800 sf 18 SQ 473 378 315 302 280 270 236 229 176 1900 sf 19 SQ 499 .399 333 319 296 285 249 242 186 2000 sf 20 SQ 525 420 350 336 311 300 263 255 195 2100 sf 21 SQ 551 441 368 353 327 315 276 267 205 2200 sf 22 SQ 578 462 385 370 342 330 289 280 215 2300 sf 23 SQ 604 483 403 386 358 345 302 293 225 2400 sf 24 SQ 630 504 420 403 373 360 315 305 234 2500 sf 25 SQ 656 525 438 420 389 375 328 318 244 2600 sf 26 SQ 683 546 455 437 404 390 341 331 254 2700 sf 27 SQ 709 567 473 454 420 - 405 354 344 264 2800 sf 28 SQ 735 588 490 470 436 420 368 356 273 2900 sf 29 SQ 761 609 508 487 451 435 381 369 283 3000 sf 30 SQ 788 630 525 504 467 450 394 382 293 PATCHING CAULKING PAINTING Dents, chips and cracks can be filled with For best results use a latex sealant that complies It is recommended that James Hardie products be a cementitious patching compound. with either ASTM C834 or ASTM C920 (Grade NS, painted with 100% acrylic topcoats. Do not paint Class 25). Caulking should be applied in accordance when wet. For application rates refer to paint with the caulking manufacturer's written instructions. manufacturers specifications. Back -rolling is recommended if the siding is sprayed. RECOGNITION: In accordance with IMES Legacy Report NER-405, Hardiplank lap siding is recognized as a suitable alternate to that specified in: the BOCA National Building Code/1999, the 1997 Standard Building Code, the 1997 Uniform Building Code, the 1998 International One- and Two -Family Dwelling Code, the 2003 International Building Code, and the 2003 International Residential Code for One -and Two -Family Dwellings. Hardiplank lap siding is also recognized for application in the following: City of Los Angeles Research Report No. 24862, State of Florida listing FL#889, Dade County, Florida NOA No. 02-0729.02, U.S. Dept. of HUD Materials Release 1263c, Texas Department of Insurance Product Evaluation EC-23, City of New York MFA 223-93-M, and California DSA PA-019. These documents should also be consulted for additional information concerning the suitability of this product for specific applications. James Hardie® Building Products Additional Installation Information, Warranties, and Warnings are available at www.jameshardie.com Corporate Headquarters 26300 La Alameda, Suite 250 Mission Viejo, CA 92691 Approved by Lowe'a 111111 Improving Home Improvement W2121601 © 2004 James Hardie International Finance B.V. TM, SM, and 0 denote trademarks or registered trademarks © 2004 by Lowe's". All rights reserved. Lowe's and the of James Hardie International Finance B.V. C is a registered trademark of James Hardie International Finance B.V. gable design are registered trademarks of LF Corporation. JH2O55DIY 11/04