Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSOFFICE USE ONLY: -<-- Date: ':` / F- D� Fee Due: , 65-0 . ro Rett'Pll ALL INFO MUST BE CbMPaTE & FILLED IN TO St. Lucie County Building and Zoning 2300 Virginia Avenue Ft. Pierce, FL 34982-5652 772-462-1553 Permit #© .y()V-7!z?-C?- BE ACCEPTED SCANNED By St. Lucie County APPLICATION FOR ALUMINUM. STRUCTURES PERMIT - PROJECT INFORMATION 1. LOCATION/SITE ADDRESS: --3 V eA A G ;L f-T , y" 2-E I GE 2. S/D NAME: S e A*I�ZC 14 i- -KCS C.C. SITE PLAN NAME: C 0 4 r✓TR.� G L 416 3. PROPERTY TAX ID #: % O I �� - - c� o o / — 6 p p — ✓ 4. LEGAL DESCRIPTION (attach extra sheets if necessary): J `7 39 E I-155S AJ 0 6 9. -T-y FT — �3 $ .9q 4C- 231 ti — c� 5. PLAT 6. PAGE 7. BLOCK 8. LOT BOOK NO. / NO. NO. 9. PARCEL SIZE: ACRES/SQ FT. -�� � O LOTDIMENSIONS Ll 6 10. SETBACKS (ACTUAL) FRONT: 1 ' BACK. RIGHT SIDE: � LEFT SIDE: 11. TYPE OF STRUCTURE (CHECK ALL APPROPRIATE BOXES FOR EACH AND EVERY TYPE OF STRUCTURE) TYPE OF CONSTRUCTION N=New. A= Addition R = Rebuild SG = Slab on Grade SR = Raised Slab WD = Wood Deck DIMENSIONS SQUARE FEET OF CONSTRUCTION ❑ SCREEN ROOM ❑ NEW ❑ EXISTING X Nr CARPORT/PATIO ROOF " f ,j ❑ NEW 2� EXISTING X ❑ HABITABLE GLASS ROOM ❑ NEW ❑ EXISTING X ❑ SUNROOM ❑ NEW ❑ EXISTING X ❑ SHED ❑ NEW ❑ EXISTING X ❑ POOL ENCLOSURE ❑ NEW ❑ EXISTING R X ❑ M H ROOF OVER ❑ NEW ❑ EXISTING X ❑ POOL FENCE -_ Linear feet, ❑ ROOF SYSTEM OVER EXISTING ACCESSORY STRUCTURE ❑ NEW ❑ EXISTING X , ❑ OTHER: ❑ NEW ❑ EXISTING X TOTAL SQUARE FOOTAGE OF CONSTRUCTION L 10 12. VALUE OF CONSTRUCTION: $ The value of construction is used to determine the amount of permit fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction activities. If the value is $2500 or more, a RECORDED Notice of Commencement must be 'submitted PRIOR TO FIRST INSPECTION. SLCCDV Form No.: 001-02 Rev. 2119107 cl a 7C /2 L/s OWNER INFORMATION_= NAME: ilV iV 11r� g Le 1' C Q Ric.- ADDRESS: i a-� y w 1 �� ~` 1�dni CITY: STATE: 21P 3 �' PHONE (DAYTEVIE): n_-11) email: FILL IN NAME AND ADDRESS BELOW IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE: FEE SIMPLE TITLEHOLDER: ADDRESS CITY: PHONE (DAYTIlAE): STATE: AP CONTRACTOR INFORMATION STATE OF FLORIDA REG./CERT #: L 13G 0—T L/ i 4 j ST. LUCIE COUNTY CERT #: BUSINESS NAME: P ���`✓ Gi.E an ri,� "K-5 X,ve- QUALIFIER' S NAME: �14�i �J f�►nJJ�/ ADDRESS: S S W la-u LS K A A-y(T CITY: P$ �' STATE: F L 22P 3 5+ 9 s 3 PHONE (DAYTEVIE): % l Z) -3 Y 3 — Y q l d FAX NO. s `� �'�9 email: ARCHITECT/ENGINEER: ? A-u C E&IAA L ,04-f X ADDRESS: CITY: V F.4-0 C o STATE: FL ZIP PHONE (DAYTEVIE): (2-4) �6 S - Z 4141 NOTE: IF APPLICABLE, SUBCONTRACTOR AGREEMENTS MUST BE ATTACHED TO•APPLICATION FOR ROOFING, ELECTRIC, PLUMBING, AND HVAC ZONING REQUIREMENTS All such,structures will be subject to the requirements of the ST. LUCIE COUNTY LAND DEVELOPMENT CODE. ❑ 2 scaled plot plans showing lot size, dimensions of existing host structure, -and proposed aluminum addition. All setbacks including front, side, rear and distance between adjacent property structures in MH Parks shall be indicated on the plot plan. ❑ 2 sets of color photos for all storm damaged areas to be reconstructed. One picture must include house address number for inspection verification. ( not required for construction unrelated to storms) `�I v'■/y' '/J Ol\�+`Vi��rt ZONING SECTION Ot TOWNSHIP 3t� S RANGE MAP NO. Additional Yes ZONING LAND USERJLA LOT CVG % Permits no REPORT CODE D BIMS FEE MISC FEES TOTAL FEES y _ - � _3 } �{��}T RK ��,. {}43 4!� � h ,�J.�mL Rvl 53 �r'.F at { �S M.3.0 ^'+���:4" � !^ .7 {�C.. yi•i'ji-. �. .., �_� � _.:v r iyt__}. _.F[t_ .?i�Jsiyi�23:i..1[.`..�..-7 .:�.c:�j-ty.r�r .'�i� i•:`4i..._��='".# REVIEWS ZONING ZONING PLANS MISC. VEGETATION VALUE OF CONSTRUCTION o REVIEWED BY EXAMINER USING ICC TABLE Ut DATE L4a {� l �J �� 7. T COMPLETE . JR INITIALS c/� . o PLAN REVMW SPECIFICATION ClffKLIST PLEASE PROVIDE ONE OF THE FOLLOWING: I . V2 Sets of Detailed Plans: Dated, Signed & Sealed by an Engineer or Architect holding a Florida State professional license. ❑ 2 Sets of Detailed Plans: Designed in accordance with the AAF Guide To Aluminum Construction in High Wind Areas. (I) ANY PLANS SUBMITTED WITHOUT COMPLYING WITH THE FOLLOWING SHALL BE RETURNED WITHOUT APPROVAL. ALL PLANS MUST BE IN INK AND ANY NOTATIONS IN PENCIL WILL NOT BE CONSIDERED A PART OF A SUBMISSION. • All plans must be legible and must be designed in Architect's Scale on pages which are 81/2" x 11" or larger. • All relevant tables & details, if using the AAF Guide, must be properly highlighted and must match design checklists& drawings. • The plan view must include all dimensions; the location of the host structure and all materials must be sized and identified thereon. • All elevations must be shown, including 4`s wall detail, dimensions and all material must be sized and identified. • All primary and secondary carrier beams, spans, spacing, gauges must be shown [Example: 2" x 8" x .072"]. • All methods of fastening or other details which are relevant to the design must be identified on the Plans. • All upright column heights, sizes, spacing and gauges must be shown as follows: [Example: 3" x 3" x .050"]. • All chair -rails, roof purlins, girts, channels, knee -bracing, k-bracing, cable bracing or any other required component must be sized and identified. • All ridge beams and super gutter or fascia attachments must be identified. • All roof pans or composite panels, with gauges and spans, must be sized and identified. • All footing, slab and ISO pier designs must be on the plans, per the Architect / Engineer's plans & specifications. • All light metal alloys which are utilized shall be designed in conformity with the Florida Building Code of 2004, Chapter 20, including 2006 revisions. • Barrier railings, if utilized, shall have all materials, fasteners and height specified and shall have self -closing, self-, catching gates with picket spacing. (IT) SITE CONSTRUCTED SHEDS, HAVING ANY ALUMINUM COMPONENT, SHALL MEET ALL OF THE ABOVE REQUIREMENTS AND THE FOLLOWING ADDITIONAL ITEMS: (A) 2 copies of the current product approval [i.e. N.O.A. or State of Florida approval] with the proposed "opening" or cladding component highlighted and with fasteners and design pressures, per FBC 1714, clearly identified. (B) 2 electric schematics, in accordance with the N.E.C., if applicable. (C) Design pressures, per Table R 301.2 (2), identified on the openings of all Plans. (III) HABITABLE ROOMS/ADDITIONS DESIGNS SHALL MEET ALL OF THE ABOVE REQUIREMENTS, EXCEPT AAMA SPECIFICATIONS, AND CHAPTER 13 OF THE FLORIDA BUILDING CODE. (IV) SUNROOMS (as defined in R202 or FBC1202.1) MAY BE CONSTRUCTED; SO LONG AS THEY MEET ALL OF THE ABOVE REQUIREMENTS AND MUST BE IN STRICT COMPLIANCE WITH AAMA/NPEA/NSA2100.02 AND MEET THE FOLLOWING ADDITIONAL ITEMS: (1) The designer or engineer will state on all Plans, which Category of Design [3.1.2] will be used, inclusive of the definition. (2) If designing a Category 4 or Category 5 structure, as defined in the current Edition of 3.1.2.4 and 3.1.2.5, proper energy calculations and long form equipment sizing calculations shall be required, pursuant to Chapter 13 of the current State of Florida Building Code. (V) MOBILE HOMES (FAC 15C-2.0081- FAC 15C-2.0072): ALL STRUCTURES ADJACENT TO OR NEW ROOF SYSTEMS (Pan or Composite) OVER EXISTING ADJACENT STRUCTURES TO A MOBILE HOME SHALL REQUIRE: (a) A 4'h wall or a current, signed original manufacturer's attachment approval letter which includes the model number, serial number and current owner's name and street address. (b) That the complete guide to H.U.D. specifications be strictly adhered to. (c) A Certified Florida Engineer may design the manner of attachment of the proposed structure to the host house but shall assume full responsibility for both structures' integrity by site specific documentation. CERTIFICATION: This application is hereby made in order to obtain a permit to do the work and installations as indicated, and to obtain a certificate of capacity, if applicable, for the permitted work. NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE TO APPLICANT: IN THE EVENT IT IS NOT YOUR RIGHT TITLE OR INTEREST THAT IS SUBJECT TO ATTACHMENT, THE APPLICANT DOES HEREBY MAKE A GOOD FAITH PROMISE TO DELIVER A COPY OF THE ATTACHED CONSTRUCTION LIEN LAW NOTICE TO THE PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT, AND DOES SO AS A CONDITION PRECEDENT TO THIS PERMIT I. If utilizing the AAF Guide to Aluminum Construction in High Wind Zones, I the Contractor/Owner Builder hereby certify that the components being used, fasteners type and fastening pattern meet all the requirements for the designated wind zones established -by the county and take full responsibility for complying with the submitted design of -the structure being permitted. 2. I further certify that all the foregoing information is accurate, that no work or installation has commenced prior to the issuance of a permit and that all work shall be performed in compliance with all applicable laws regulating construction and zoning in this jurisdiction. I understand that separate permits may be required for ELECTRICAL, and HVAC, etc., not otherwise included with this building permit application. 3. I , the Contractor / Owner Builder, have verified that the existing foundation meets the requirements of the Engineer of Record and is in adequate condition to withstand the uplift and weight of the aluminum structure and said structure will not exceed the footprint of the structure that was in existence prior to removal by the storms. �n K A (�) -0ift M O C CTOR S N TURF STATE OF FLORIDA COUNTY OF The foregoing inskument w s acknowledged before rgthisday of tn� , 206 f b Q }7 P , who is erson know to me or who has produced LEZLIE WICKLINF =y = MY COMMISSION # 00 (SEAL) EXPIRES:September3U 20L,b Bonded Thru Notary Public Underwriters r P� LEZLIE WICKLINE *_ MY COMMISSION # DO 465141 IMPORTANT NOTICES: ; i , o€ EXPIRES: September 30, _ ' BondedThru Notary Public undenvaisrJ NINA 6,0-AAA N CON CTNIMIGNA STATE F FLORIDA . COUNTY OF 5k • ( ,-.-G 2— The foregoing inns ent ackn before me this 0 d`ay of ►-1 , , who is F known to me or who has produced < Y oy LEGI IE W CK INE MY COMWS SK'I'll it. rD 465141 t (SE xy� cG�.ieIGGS:.�tjliciftJ€f 30, 2009 r oz`r �oF ty :n�:r��'fNv Nrna!y';.c�:c Underwriters • TWO (2) SIGNATURES ARE RE G1�ATUR MUST BE NOTARIZED. IF APPLYING FOR THIS BUILDING PERMIT AS AN OWNER/BUILDER, THE OWNER MUST PERSONALLY APPEAR TO SIGN THIS APPLICATION IN THE OFFICE LISTED ON TIQE FRONT OF THE APPLICATION. • ALL SIGNATURES ON APPLICATION SUBMITTED SHALL BE ORIGINAL. COPIES, FAXES, OR STAMPED REPRODUCTIONS ARE PROHIBITED. • WHEN A PERMIT IS AVAILIBLE FOR ISSUANCE BUT IS NOT PICKED UP WITHIN THIRTY (30) DAYS AFTER NOTIFICATION OF AVAILIBILTTY, IT WILL BE VOIDED. IF THE APPLICATION IS RESUBMITTED, AN ADDITIONAL FEE WILL BE CHARGED. EDWIN M. FRY, Jr., CLERK i i , THE CIRCUIT COURT - SAINT LUCIt LINTY DO U FILE # 3208363 OR BOOK i , PAGE 1852, Recorded 05/12/20(z._1_.'t 08:15 AM 1M.M.M.17.7e 310t' :d t ►1 The undersigned hereby given nodes that improventant will be made to coin rail property, and 1n accordance with Chapter 713, Florida Statues the following information is provided in the Notice of Commencement I. Dsset moN of PROPERTY (Legal desenpdon and street address, hiaPulable) TAxf'otao NUNMERc 3 V-e r a Cruz SMDIMON S- T. a kp. s Country QQ. V i 11 Qkr LM =q uffr ` East].- of section 1 township 34S Range. 39Er lying N&W 6f Turnpike - Feeder Road . 2. OE1M&4 .DESCMn0N OFD4MOvttMM'. car port 3.0WtYSRIIBMMATION: .Nvmy rnn� Bu 1 n.Aaarr, 8000_ S. US1, Suite 402, P' , FL 349524hr.1h,,,., ee Simple d Name atd ad*M of f" fi*o tid'"drpf dhorthan owo� 4. CONTRACTOR'S HMMADD1=5 AND PHONE NOMEM pinnacle'South Builders., Inc. 3765 SW Hulska St. PSL, FL 34953 772-343=8910 S. SURTMSNAML.ADDtt;UUSSANDPROM CIf1M=ANt1SMAMOUM 6, LMER'S NAW. ADDR=ANa MMNE NUEt� 7. Pon= within the State ofFlonda designated by Owner upon whom notices or other documents may be served as provided by Section 713.13 (I) (a) 7., Florida Statutes: NA=ADD1=AND PHONENOA0= 7 7 2-4 6 6-15 5 3 Sraio War�el'1, manage r,l. Las Casitasr Ft. —Pierce, —FL 34951 2. to addition to himselfor herself, Owner de dilate s the following to receive a copy of the Lienoes Notice as provided in Section 713.13 (1) (b). Florida Statues , NAMS.ADDRM AND PSONs NrJMtiEBt ' 9. Expiration date of nati of commit (the expiration dam is 1 year from the data of according unless a diffeseat date is sPecilWI: . _, 20 signature oruivaer or Owner's Authodud OMeer/DlrectorMartner/Asanager State of Ftofida Countyof S•t . Lucie Harygy A. Newman, Vice -Pre PriatName and Provide Signatory's Tide/Office 'the foregoing instrument was acknowledged befom me this 1st day of May 20 0 8 By _$3ytiCy A. Newman as Vice -President S, . -fact) (tame of person) (type ofautbo*....e.g, officer. trustee, attorney For Wynne Building Corporation (name of party on bdmlf of whom instrument was exneuted) .� t Personally known or pmduwd the following type, of iderttifrcxtion: - � _ �(k •, , - SUSAN lMAGM . MY COMM18810N 00 is9l>t1�i Sigr aun of Notary Public) I�B: fah 3, 201 n °� vubic Under Penalties of.pejury. I declare that I have read the foregoing and that the facts in it are true to the best of my knowl t;' d: U-1 A belief (Section 91525, Florida Statutes). a) a er{s)' Authorized OftleedDirector/ PartneNMasagerwho sighed above U- iL_ Ui ByBY Rev .el-09 t<r (S ReOorduljo < " t T = T° caes]p-gip © C t UV Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 http://stl ucieco. govice PROPERTY INFORMATION Address: 3 VERA CRUZ City / State / Zip: FORT PIERCE Parcel#: 1301-111-0001-000/5 Zoning: PUD Review Comments FL 34951 Jurisdiction: St. Lucie County Lot # : Block: APPLICATION INFORMATION Permit Number: 0804-0221 Activity Type: Other Permit Type: MA/RV Addition Existing Concrete CONTRACTOR INFORMATION Contractor Name: JAY W BENNY Business Name: PINNACLE SOUTH BUILDERS INC Business Addr: 3765 SW HULSKA ST City / State / ZiF PORT ST LUCIE, FL 349: Page 1 Owner(s): WYNNE BUILDING CORP Application Type: Building Permit w/o subs Other Activity: ALUMINUM STRUCTURE Stories: 1 Automatic Sprinkler System? ❑ Fax Number 772-343-8910 REVIEWS AND COMMENTS Review Type Status Reviewed By Date Started Date Complete Date Released Documents Missing Pending 04/23/2008 1 Comment NEED TO BRING IN NOC WITH PICK UP O Front Counter Review Complete Notified for Pickup Pending t Plans Examiner Review Incomplete 04/29/2008 1 Comment ENGINEER TO CERTIFY 04/29/2008 2 Comment ENGINEER TO DESIGN' * NO ATTACHMEP0 04/29/2008 3 Comment COMMENTS MAILED Zoning Review 1 Complete Audrey Humphrey 04/18/2008 04/18/2008 04/29/2008 RETE 3.5" SLABS ON THE PLANS ERE THE COMPOSITE PANEL JOINS THE MOBILE ROOF MV REGS ONLY FLASHING. OWNER AND CONTRACTOR AS OF THIS DATE Lydia Galbraith 04/23/2008 04/23/2008 TRANSMISSION VERIFICATION REPORT TIME 04/29/2008 16:02 NAME SLC INSPECTIONS FAX 7724626443 TEL 7724622165 SER.# BROE5J278862 DATE,TIME 04129 16:02 FAX NO./NAME 93438910 DURATION 00:00:20 PAGE(S) 01 RESULT OK MODE STANDARD ECM .. +VA. • .azs..m Code Compliance Division 2300 Virginia Avenue Ft Pierce, FL 34982 Phone: (772) 462-1653 Fax: (772) 462-2522 http:ilstluclogo.gov/0o Review Comments PROPERTY -IN- F_O.,RM&U1 Address: 3 VERA CRUZ City l State / Zip: FORT PIPRCE FL 34951 Parcel#: 1301-111.0001.00015 Jurisdiction: St. Lucia County zoning: PUD Lot # : Block: Page 1 Owner(s): WYNNE BUILDING CORP APPLICATION Iff0kMATION Permit Number: 0804-0221 Application Type: 6uiiding Permit w/o subs Activity Type- Other Other Activity: ALUMINUM STRUCTURE Permit Type: MA1RV Addltlan Existing Concrete Storigs: 1 Automatic Sprinkler System"? El CONTRACTOR INFORMATION Cotrtractor Name: JAY W DENNY Fax Number 772,343-6010 Business Name: PINNACLE SOUTH BUILDERS INC Business Addr: 3765 SW HULSKA 5T City I State 1 Zil PORT ST LUCIE, FL 349-, REVIEWS AND COMMENTS Revimillas Status Reviewed By Documents Missing Pending 04/23/2008 1 Commant NEED TO BRING IN NOC WITH PICK UP D Started Data Complete Date_Rtl@d�@d Front Counter Review Complete Audrey Humphrey 0411812008 0411812000 Monday, Apr 14, 2008 11:28 AM ��i�isa liau-re�`� ,f ► � ---1 Code Compliance Division permit 1 , • 2300 Virginia Avenue Ft. Pierce, FL 34982 �I Phone: (772) 462-1553 Fax: (772) 462-2522 Address 3 VERA CRUZ Owner(s) WYNNE BUILDING CORP FORT PIERCE 34951 Historic I No Jurisdiction St. Lucie County __ Parcel # 1301 111 0001 000/5 S/D ISpanish Lakes Country Club Vill I Block Lot # FLU RU Zoning PUD Flood Mai Flood Elevation Flood Zone APPLICATION INFORMATION Property Maintenance >> Add A New Permit >> Application Type Building Permit w/o subs Status Void 0605 0946 Activity Type Other Expiration 01/10/2008 Other - Specify ALUMINUM STRUCTURE 547 Permit Type MA/RV Addition Existing Co Date Applied 05/31/2006 Taken By serranob Location Mainland,l Date Issued 07/19/2006 Issued By bushs :Iat Fee Valuation Date Finaled Posted By Job Address 3 ; Y Date Voided Please explain in Additional Commern VERA CRUZ���f,i�tr�„ ,p , �', . ,�+�a ; , . CONTACT INFORMATION Add Application Contact >> Category Type O C f t Property Owner Property Owner Contractor Contractor Name Business Address Email WYNNE BUILDING CORP 12804 SW 122 ND AVE MIAMI FL 33186 pen on rac or . Registration Form Phone (772) 878-5513 ext Fax ( ) Mobile ( ) Pager ( ) TRADESUB . Trade Permit >> Sub-Trade Permit Permit Type Sub Trade Status Contractor Taken By Company Date Applied Owner / Buildier Issued Issued By Sub -Trade Job Description Expiration Finaled Finaled By Units 1.00 Floors- Buildings #Bedrooms #Bathrooms �- -- Total Sq. Ft. 0.00 Min Flood Elevation Flood Map Flood Zone FCC 909 Mobile Home/Recreational NOC Required ® NOC Receivec ® NOC Expiration 05/31/2007 Setbacks Front 25.00 Back Left Side 16.00 fight Side 19.00 Job Description Additional Info RECONSTRUCT 17 X 22 CARPORT AND 3X12 FRONT OVERHANG - DUE TO STORM DAMAGE- MEETING ALL REQUIRED SETBACKS Please include the date and your name when adding Information. 12-7-07 change of contractor from BACKYARD PATIO ROOM INC (23331) TO WYNNE DEVELOPMENT CORP (8898) NO CHARGE AND RENEWED PERMIT (L.GERSTEMEIER) **1/6/07 faxed letter to cotractor letting them know permit will expire on 2/7/07 (boones)*** Faxed permit ready for p/u. dw 7/7/06 ** 03/25/2008 ** Need letter from Wynne to void this permit as they cannot use bennett engineering * Mike Spalla to re -apply with new permit and current engineering * OK to use Bennett Engineering as he is a qualified user * r. Code Compliance Division 2300 Virginia Avenue Inspections Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 48 -htto://stl iuclec ucieco.aov/ce Inspector Comment: le -inspection 2 Code Compliance Division 2300 Virginia Avenue Inspections Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1148 httn://stlucieco.aov/ce 17X22 1PORT AND 3X12 FRONT OVERHANG - DUE TO STORM DAMAGE- MEETING ALL REQUIRED SETBACKS Property Owner Name JWYNNE BUILDING CORP Phone (772) 878-5513 Contractor Business Name Inspection Notes 2-7-07 RENEWED PERMIT WITH $50.00 FEE FOR 30 DAYS FOR FINAL gSPECTION PER NOTE ATTACHED TO FILE (L.GERSTEMEIER) Date Scheduled Priority Status Max Expiration Date 01/10/2008 Inspector (Code Inspector Date Inspected 995 Fourth Wall, Beam, Knee Br 2 995 Fourth Wall, Beam, Knee Br 2 157 Roof - Composite/Pan Attacl' 2 904� Fastners 2 999 Final Inspection 2 08/11/2006 807 Stop Work Order 1 Approved Peggy Billing 08/11/2006 Jim Beams 12/10/2007 999 Final Inspection 2 Disapproved Jim Beams 12/10/2007 Jim Beams 01/08/2008 904 Fastners 2 Disapproved Jim Beams 01/08/2008 Jim Beams 01/08/2008 157 Roof - Composite/Pan Attacf 2 Disapproved Jim Beams 01/08/2008 Jim Beams 01/08/2008 995 Fourth Wall, Beam, Knee Bra 2 Disapproved Jim Beams 01/08/2008 IVR Access 01/08/2008 999 Final Inspection 2 Disapproved -Reinspect Fi Jim Beams 01/08/2008 Lorie Gerstemeier 12/10/2007 904 Fastners 2 Disapproved Jim Beams 12/10/2007 Lorie Gerstemeier 12/10/2007 995 Fourth Wall, Beam, Knee Br 2 Disapproved Jim Beams 12/10/2007 Lorie Gerstemeier 12/10/2007 157 Roof - Composite/Pan Attact 2 Disapproved Jim Beams 12/10/2007 Lorie Gerstemeier 12/10/2007 999 Final Inspection 1 2 Cancelled by Customer IVR System 12/07/2007 P A/ IV 6 LE -T vv Psi L Ll 9 7-3 SPANISH LAKES LAYOUT APPROVED! CRAIG COMMUNITY MANAGER,, ------------ - -i N m 0 U) -n m z mz Ej m rn 71� m rJ W*YIVTvk W(-, PZCA(-,- ) rL N -, P, y L L- L4-6 I -VI )-) P MBENGINEERING, INC. CONSULTING ENGINEERING VrMvOIA BOWLES VILLAMIZAR & ASSOCIATES Certificate of Authorization #3728 May 9, 2008 Mr. Joe Cicio Plan Reviewer St. Lucie County Building Department 2300 Virginia Avenue Fort Pierce, FL 34982 Subject: 3 Vera Cruz Fort Pierce, FL 34951 Engineer's Project Number: 08-179 Dear Mr. Cicio: This letter is to address your plan review comments dated 4-29-2008 with the following responses: 1. Structure to be supported on existing 3-1/2" concrete slab. Condition is to be field verified by contractor. 2. Roof panel — mobile home joint detail is attached to this letter. Should -you have any questions regarding the above subject, please call. Rodolfo V10,M-- FL P.E. #00 RV/dsc 2455 - 14th Avenue Vero Beach, Florida 32060 Phone (772) 569-0035 Fax (772) 778-3617 , P.E. E-mail: mbveng0mbveng.com A The Boulevard Professional Center 1600 W. Eau Gallie Blvd., Suite 203 Melbourne, Florida 32935 Phone (321) 253-1510 Fax (321) 253-0911 BEAMf CONNECTION PER F LANS ----- -- --FLASHI-N-G- DETAIL - -- ---- ---- -- LU Aodam #0:OQO 9 2908 Design Certification for Wind Load Compliance Name: wyd & CoyzP Permit # Address: V612A C120 7-- Construction Type: Certification Statement: I certify that, to the best of my knowledge and belief, these plans and, specifications have been designed to comply with the applicable structural portion of the Buildirig Codes currently adopted by 5 i j04f:,l F - County. I also ceriifythat- tructural elements depicted on these.plans provide adequate resistance to wind loads and forces specified by curtbnt code provisions. Ges inn 'Parameiers and Agiumptioins Used: (Please 60h*retappropriate box) 1. Florida Building Code 2004 Edition j(' ASCE 7-98 Section 6:5 2. Building Design is: Enclosed / `Partially Enclosed Open Building /y r 3. Building Herght Uj 4. Wind Speed Used in Building Design: A03 second gust 4MMMJ 5. Wind Exposure Classification (Refer to exposure tables in Building Code identified in line #1): _ (� _LL 6. Importance/Use Factor. Following pressures include importance factor table 2002.4- I,D 7. Loads: Wall PSF Roof �� PSF l Certfication # Design Firm: 1M13V "N�'t�ut � 1��, WG.Date: 2-/2 51� � **FOR 140 WIND ZONE, ATTACH PANELS W1318 "X (THICKNESS OF PANEL + I ") S.S. LAGBOLTSIN ALU 3I BEAMW/l,W"FENDER POLYROOF PANEL DETAIL * SEE LAYOUT FOR MEMBER OR MATERIAL SIZING GENERAL CONSTR. NOTES: NOTE: SHTCHALL S.M.B.'S WIW12 S.M.S. SCREWS ON18" a (a.) ALL CONCRETE SCREWS MINIMUM EMBEDMENT OF3"INTO SOLID CONCRETE. AIINIMUMEDGEDISTANCES TIMES DIAMETER (b.) U-CHANNEL THICKNESS: .062 - <EXPOSURE 'B" .I25-> EXPOSURE "C" FOR 2 "X 6" POST OR BIGGER, USE STR UCTUR9L .25" CLIPS (a) CONCRETESCREWSIZE: SCREENROOM: 114" POOL ENCLOSURE: 318" OR OTHERWISESPECIFIED (d) LENGTHOFANGLEAND/OR PLATE VARIES BYSIZE OF COLUMNAND/OR BASEPLATESIZE (e) CONCRETE SCREWSIZE- POOL ENCLOSURE: EXPOSURE "B" -114" EXPOSURE "C" - 318" USE 114" FOR ALL SCREENROOMS FOR 6" POST OR BIGGER, USE 2 "X2 "XI/8"X BEAM DEPTH EACHSIDE SEE TABLE 503 FOR FASTENING DETAILS BEAMS MAY OCCUR ONBOTHSIDES 0. BEAM 2 " X RECEIVING CHLj%— ANNEL SAID* SEE TABLE 200 FOR FASTENER DETAIL BEAM TO BEAM CONNECTIONDETAIL (2) 3/8"CONC SCREWS 2-1/2"X2-1/2"X2"X (b)" ,n FOR "B" WIND SPEED NO PLATE "U" CHANNEL (CLEAT) NECESSARY -FOR "C" WIND SPEED, INSTALL.125" PLATEX(b)"XS.M.B. BEAM '� SIZE PLUS 5"MIN. MAHN. (6) #12 X 314" S.M.S. SCREWS, ONFACE OFBEAM OR POST A KNEEBRACE REQUIRED IFPOST OT SET IN CONCREJ ic KNEEBRACE* + AIIN. 24" UNLESS OTHERWISE APPROVED BY ENGINEER KNEE BRACE TO POST DETAIL OPTIONAL EXTERNAL 2-M X2-1/2"X1,12 CONNECT KNEE BRACE TO POST & ANGLE W/(2) (a)(c) BEAM W/MIN..050" RECEIVING CHANNEL, "H" BEAM OR GUSSET PLATE - SEE TABLE 200 FOR FASTENING DETAILS - OPTIONAL (2)114" THRU BOLTS W/WASHERS & LOCK NUTS FOR 140 WIND ZONE, ATTACH PANELS W1318"X (THICKNESS OF PANEL + 1'9 S.S. LAG BOLTS 8" 0.0 W/1-1/2" FENDER & WASHER @ 8" n d- _ FnR 130 WIND ZONE, IO" O.0 J "X(*) "PLUS S.S. BOLTS 9CKNUTS & 'ASHERS OPTIONAL CENTER NOTCH POST TO BEAM CONNECTION DETAIL ARE THE RESPONSIBILM OF THE CORWOR OF RECORD TABLE 503 FASTENER SCHEDULE BEAM/SECTION MINIMUM POST SIZE BOLTSREQUIRED 2"X 3" OR 4" HOLLOW OR SNAP # OFBOLTS DIAMETER 3 "X3 "X 060 2 318" 2"X4"S.M.B. 3"X3"x060 3 318" 2"X 5" S.M.B. 3"X3"X..060 3 112" 2"X611S.M.B. 3"X3"X060 3 518" 211X7"S.M.B. 3"X3"XO60 4 518" 2"X8"S.M.B. 3"X3"X.093 3 5/8" 2"X 9" S.M.B. 3"X3"X.093 3 5/8" 2"X 9" S.M.B. 3"X3"X 093 4 I/2" 2"XIO"S.M.B. 1 3"X3"X093 4 518" DBL 211X 911(H) S.M.B. 4"X411x125 2 3/4" DBL 2"X 10" S.M.B. 4"X4"Xl25 3 1 5/8" S.M.B.=SELFMATING BEAM THESE PLANS AND ALL PROPOSED WORK _ . ARE SUBJECT TO ANY CORRECTIONS . #12SMS- 8 INCH 0. C REQUIRED BY FIELD INSPECTORS THAT MAY PE NECESSARY IN ORDER TO Cc ,. QRg11 Y WIN 7 RS IP�a AKE O®BWs POST* 3"POLYPANEL 3"POLYPANEL 'HI MOLD ROOF JOINER OR DOUBLE � �O �9 o a2 RECEIVING CHANNEL DETAIL 9 (2)1/2" S.S. TOR j BOLTS W/LOCK NUTS & .; WASHERS c - . 4y . •'sZ�0. - . (2)1/2" CONCRETE ��A� ANCHORS EMBEDMENT COLUMN TO FOOTER CONNECTION DETAIL - IF REQUIRED 2-112 "X 2-1/2 "X 2 "X (b) " POST "U" CHANNEL A 1 (2)1/2" S.S. THRU OPTIONAL EXTERNAL BOLTS W/LOCKNUTS & 2 2-I/2" WASHERS ANGLE (a) 4 (2)1/2" CONCRETE °a ANCHORS W/3" EMBEDMENT A. 'a COLUMN BASE CONNECTION "U" (r7=ANNEL DETAIL 5/8"BOLTS W/LOCA WASHERS FOR 140 WIND ZONE, ATTACH PANELS W/318 "X (THICKNESS OF PANEL + 1 ") S.S. LAG SCREWS OR 914 SELF TAPPING TECHSCREWS W/1-111 " FENDER & WASHER @ 8" O.C- FOR 130WINDZONE,10"OC ST LUCIE COUNTY BUILDING DIVISION FOR Op L CE REVIEWED BY DATE .0 PLANS 'ND PERMIT MUST BE PT ON JOB OR NO INSPECTION WILL BE MADE (3) 518" X 3A," BOLTS — W/L0CK NUTS & WASHERS, BOTH SIDES NOTE: (4) BOLTS REQUIRED @ 2 "X10" (t).125" PLATEX (d) XS.M8. SIZEPLUS 5" MIN. WIAMV (6) #12 X 3/4" S.M.S. SCREWS .POST TO BEAMIROOF CONNECTIONDETATT Contractor: Job # = 0003 DATE: 02-07-2008 DRAWN BY: IZ CHECKED BY: SHEET NO. 2 OF 2 PROJECT FOR: WYNNE_ CORD__ 3 VERA CRUZ PORT SAINT LUCIE ST. LUCIE COUNTY, FL ROCHELL PALUZZI STRUCTURAL DESIGNS 455 19th PLACE VERO BEACH,- FL 32960 PH: 772-465-5441 ,,FAX: 772-465-5442 NOT TO SCALE Earn GENERAL NOTES I 1) 7WSSTRUCTUREHASBEENDESIGNEDANDSEALLBEFAENC.4TEDINACCORDANCEWITHTT&'EE REQURZEMENTSOFTHE2004FLORIDABUILDINGCODE (FBC) &ASAMENDEDBYTHE2006SVPPLEMENT.$ T HE 2004AL UMDV DMDESIGNMANUAL ALL LOADSBASED ON ^60%SCREEN OPENING, FLAT SPLINE & fBCTABLE2001.4 (1))(NON-EV=, CATAGORYI (I=0.77) (HM4ANDASCE7--2002 • ALTERAT70NS,ADDT(TONS,HIGHLIGBTSOROTBERMARMGSTOTHISDOCUMENTARENOTPERMUTED AND WILLANNULL OUR CERTINC4270N. ' 2) THEEXISn7VGSTRUCTUREISNOTCAPABLEOFSUPPORTINGTBBLOADSDIIDOSEDBYTHLSSTRUCTURE CONTRACTORBUILDERISRESPONSIBLETOCONFIRMANDCONSTRUCTTOTBEDETAILSINTHESEPLANS CONTACT ENGINEERIFSITE CONDITIONS VARY. 3) RESPONSMUITYWILLBEOFTBEBUMDER/CONTRACTOR,TOINSURETHEEDST7NGSTRUCTURE&MATERIALSARE SOUND. REPLACE ALL STRUCTURALLYDEFEC77VEMATERIAi_S 4) ALL MEMBERSSHALL BEAND HA VEBEENDESIGNED USINGALUMINUMALLOYTYPE606346, UNLESSSPECIFIED OTRF-RWISE ALL AL UMDVUMEXT RUSIONSSPECIFIED I7V THISPROIECTSHALL BEASSHOWNINTREAAF. MANUAL 5) ANYFAST?;NERSSTRD'PEDORNOTADEQAUATTZYEOLDEMSHALLBEREPLACED. 6) ALL FASTENERS TO BE 2024-MALLOY, NON-MAGNET(CSTAINLESS STEEL, OR CADMIUMPLATED OR OTHERWISE CORROSIONRESISTANT MATERLAL AND SHALL COMPLYWHHS.LIC, SPECYFICA21ONS FOR ALUM STRUCTURES- SEC170N1, TREALUMUMMASSOCIAY70N, INC &APPLICABLE FEDERAL STATE & LOCAL CODES 3x3 3x3 -4i'-2 3x3 M 3x3 a 3x3 a p MQO 3x3x 090 POSTS (TYP) I) ALL TAPCONSMUSTBE GRADESITWCARBONSTEEL TAPCONS O,REQUIVALENT Wl- 3/"EMBEDMENT, 3"MD1 EDGEDLSTANCF,FASTENEDTOMDVIMUM250OPSI CONC�ETE� 8) ALL EXPOSED SCREWHEADSINROOFTOBECAULSED. 9)ENGINEERSEALAFFLVEDEERETOVALIDAT7:SSTRUCTURAL`DESIGNASSEOWNONLE USEOFTHIS SPEQFIC4770NBYCONTRACTOIt ETAL IIVDEm7FIESANDSAYES ARAffXM HLSENGINEERFORALL COSTSANDDAMAGESINCEUDINGLEGALFEESANDAPPELaMFE eAESULTINGFROMMATERIAL FABRTCAT70N,SYSTEMERECT70N, AND CONSTRUCITONPRAL7TGESBEYONDTHATWHICHISCALLED FORBYLOCAL, STAT SAND FEDERAL CODESAND FROMDEVI'AT1'OIgOFTHISPLAN. &'--*, 10) EXCEPTAS EXPRESSLYPROVIDED INTHISSPECIFICATION, NOADD�TONAL-CERT7FICATIONSOR AFFB M 77ONSARELVFMED. 10 �$I[ 11) SEAL ALL lOINTSW/CONnNUOUSCAumm 12) ROOFPPTCHSHALLBEAMIN.OF%"PERFOOTANDAMAX 2%"J-ERFOOT.. 13) COMPOSTTEPANELSMUSTBESEAMEDATSIDESANDEND. 14) ALL CONCRE7EMUSTHAVEMUMfUMCOMPRESSIVESTRENG71I9F2,SOO PSL WIND SPEED =140 M.P.H. WIND EXP. CLASSIFICATION = "B" 3" POLYROOF-.024 SIDE ELEVATION LEGEND X = ❑PTI❑NAL ❑B=❑PEN BACK ❑B=1X2 OR IX3X,044 KB=KNEE BRACING KB=2X3 = 2X3X,045 WB=WINDBRACE WB=2X2 = 2X2X,090 KP=KICKPLATE SP=S❑LE PLATE SP=1X2,1X3X,044 OR RECEIVING CHANNEL 1X2 = 1X2X,044 PATI❑ 1X3 = 1X3X,044 PATI❑ 2X2 = 2X2X,044 PATI❑ 2X2H = 2X2X,090 2X3 SMS= 2X3X,045 SELF MATING SNAP 2X3 = 2X3X,045 PATI❑ 2X3 S = 2X3X,050 W/6 SCREW BOSSES 2X3 SPECIAL = 2X3X,063 6005 ALLOY 2X3H = 2X3X,090 3X2 = 3X2X,070 PATI❑ 3X3 = 3X3X.093 PATI❑ 3X3S = 3X3X,072 W/2 SPLINE GROVES 2X4 = 2X4X,050 SMB OR PATI❑ 2X5 = 2X5X,050 SMB 2X6 = 2X6X,050 SMB 2X7 = 2X7X,055 SMB 2X8 = 2X8X,072 SMB 2X9LT = 2X9X,072 SMB 2X9H = 2X9X,082 SMB -2X10L = 2X10X,092 SMB 2X10H = 2X10X,125 SMB 3"POLYROOF-.024 2x8 SMB 2x4 KB (tYP) eerr� M M 4th WALL ELEVATION Contractor: Job # = 0003 DATE: 02-07-2008 DRAWN -BY: IZ CHECKED BY: SHEET NO. 1 OF 2 PROJECT FOR: WYNNE XORP - 3 VERA CRUZ PORT SAINT LUCIE ST. LUCIE COUNTY, FL ROCHELL PALUZZI STRUCTURAL DESIGNS 455 19th PLACE VERO BEACH, FL 32960 PH: 772-465-5441 FAX: 772-465-5442 SCALE: 1 /8" = 1'0"