SUBMITTED PAPERS
DATE: Q FEEI RECEIPT #: PERMIT #: G ry . St. Lucie County Building & Zoning Department CF3y 0 2300 Virginia Avenue Fort Pierce, FL 34982 L"Cle Cri! rnfr, 772-462-1553 APPLICATION FOR STORM SHUTTER PERMIT SEE REVERSE SIDE FOR INSTRUCTIONS 1. LOCATION/SITE ADDRESS: _ 5u Ito CQ 55 a 0c,��. FA PARCEL ID NUMBER: 3qU a _ l01 0-M (�qq -00p- 2 3.- DESCRIPTION OF PROJECT OR WORK ACTIVITY: 4. TYPE OF STRUCTURE: SFR 5. OWNERS INFORMATION Name: 4xA Address: 1�rrcV City: State: TTL Phone: _12zip. _ Type of Surface attachment: Wood Frame OTHER 6. CONTRACTORS INFORMATION FL REG/CERT #: Cd 6G-3, COUNTY CERT #: Business Name: if 40 /41 150 sOilaih rMotdo, (d + r , --a 1-1 I c, 0 ', v -;tUQK' .1 Concrete _Masonry Other Product Type Minimum Design Pressure Product Compliance Report # Method of Attachment As per 1707.4.4.1 FBC 120 mph 130 mph 140 mph 140 Exp. C SBCCI, Dade Other Anchor Type Anchor Spacing Impact Glazing Removable Panels ��,,y 1 " O.C.- ccordion 4. Roll Up Colonials Other ALL PRODUCTS SHALL BE LABLED SBCCI OR DADE COUNTY FOR DETERMINING IMPACT RESISTANCE FROM WIND BORNE DEBRIS. **SEE FINAL INSPECTION PROCEDURE FOR EXISTING RESIDENTIAL STRUCTURES ON BACK. 7. VALUE OF CONSTRUCTION: $ OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in compliance with all applicable laws regulating construction a ning. PRINT QUALIFIERS/OWNERS NAME SIT O QUALIFIER/OWNER STATE OF FLORIDA, COUNTY OF / ACKNOWLEDGED BEFORE ME THIS DAY OF 20U WHO IS PERSONALLY KNOWN TO ME V OR WHO HAS PRODUCED ° AS IDENTIFICATION. `/�?Di�l4--L • L/9Tas SIGN TURE OF NOTARY I TYPE OR PRINT NAME OF NOTARY *NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. -- ,�. M01RA L. tATOc• MY COMMISSION 0 DI) b659i8 * EXPIRES: August i2. 2010 311 ...{, e• Bonded Thru Notary public Underwriters P, Friday, Apr 18, 2008 01:10 PM EDWIN M. FRY, Jr., CLERK OF THE CIRCUIT COURT — SAINT LUCIE COUNTY FILE # 3195938 OR BOOK 2!3" PAGE 1119, Recorded 04/18/200" "t 11:43 AM PATE OF FLOHiuA -ST• 1_IiOIIr GOO?ay LNJ l,rt �, dVoI'STOCERTIFYTHATTHIS ISA� AFTER RECORDING RETtiRN TO: :RUE r. N D G O�i'1)Ri E G T Y OF T H is QJ cc F AN FRY, , CL K : ; `Q i ' PERMITN!MBER: CG �fl 4Yk iy yZ,6e,r; ••is crc fUr rtcnnlin� ��'/r pQ UN10�cr.,' The undersigned hereby given notice that improvement will be made to certain real property, and in accordance with Chapter 711. Florida statutes the following information is provided in the Notice of commencement. 1. DESCRIPTION OF PROPERTY (Legal description and street address) TAX FOLIO NUMBER: 3qo a' 4,ro- 0 6499660-3 SUBDIVISION-:Z aL'lICINOCK-9�TRACT LOTT_BLDG UMT 69 2. GENERAL DESCRIPTION OF IMPROVEMENT: 3.OWNER INFORMATION: a. b. Address 5 41 to 0tSs1o, bD d. Name and address of fee simple titleholder (if other than 4. CONTRACTOR'S NAME, ADDRESS AND PHONE NI 5. SURETY'S NAME, ADDRESS AND PHONE NUMBER AND BOND AMOUNT: 6. LENDER'S NAME, ADDRESS AND PHONE NUMBER: C. interest in property . 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13 (1)(a) 7., Florida Statutes: NAME, ADDRESS AND PHONE NUMBER: 8. In addition to himself or herself, Owner designates the following to receive a copy of the Liedor's Notice as provided in Section 713.13 (1)(b), Florida Statutes: NAME, ADDRESS AND PHONE NUMBER: 9. Expiration date of notice of commencement (the expiration date is I year from the date of recording unless a different date is speciPed) , 20 of Owner or Owner's Authorized Officer/Director/Partner/Manager J N t 11 a tw Print Name and Provide Signatory's Title/Office State of Flori¢p County of l __Ict��� � p The foregot instrument was acknowledged before me this f�J� day of _ (�J[li1fC .0 .20 Op By b r7 tdt I b iim-s as p t Jr4 E!E~, (Printed name of perso igning above) (Type of authority ... e.g. (honer, officer, trustee, attorney in tact) For se, (Name of party on behalf of whom instrument was executed) Personally Known_ or produced the following type of ID!�__ TAPAII.NAttT1@N %1 � %%i Lf,H /%l ��i �� �' MY COMMISSION i 3 , 2011 EXPIRES Nov�tiba30, 2011 (Printed Name of Notary Public) (Signature of No ary Public) (Seal) erawt[wNorryrtl:loWtlrr Under penalties of perjury, I declare that I have read the foregoing and that the facts in it are true to the best of my knowledge and belief (section 92.525, Florida Statutes). Signature(s) of Owner(s) or Owner(s)' Authorized Offi rector/Partner/Manager who signed above: By Rv Rev.QV30/2oo7(-rding) (Signature (Printed Name) Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1148 http://stiucleco.gov/ce Issued: 04/18/2008 Job Location: 5416 CASSIA DR Permit Type: Storm Shutter Job Description: BUILDING PERMIT Conf #: 797 Permit #: SLC- 0804-0222 City: FORT PIERCE INSTALLATION OF CLEAR PANELS ON 6 OPENINGS -ACCORDIONS ON 10 OPENINGS Page 1 S/D Indian River Estates Unit 9 Lot: 9 Block: 72 Parcel: 3402-610-0067-000/3 Contractor WHITTEN WILLIAM R SHIELD OF PROTECTION SYSTEMS II (772) 878-7332 1351 SW MACEDO BLVD Property Owner ROBERT S WILLIAMS 5416 CASSIA DR PORT ST LUCIE, FL 34983 (772) 465-9547 FORT PIERCE, FL 34982-3835 Setbacks Left: Right: Front: Rear: Zoning: RS-4 Number of Units: 1.00 Floors: 1 Buildings: 1 Square Footage: 0.00 Minimum Floor Elevation: Flood Map: 281G Flood Zone: AH Elev: 17 Permit holder acknowledges through acceptance of this permit that separate permits must be obtained as required by the Florida Building Code including those for all electric, plumbing, mechanical, roofing, and structural work. Further, he/she acknowledges responsibility to comply with all requirements of the 2004 Florida Building Code. NOTICE: In addition to the requirements in this permit, there may be additional restrictions applicable to this property that may be found in the records of this County, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. s:553.79(10), F.S. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR BUILDING IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. s.713.135, F.S. Christopher Lestrange Building Official Date For Automated Inspections, Call (772) 462-1261 For Questions, Call (772) 462-2172 St. Lucie County Land Development Code Section 11.05.01 (A) (2) states; Building Permits shall expire and become null and void if work authorized by such Building Permit is not commenced, having called for and received a satisfactory inspection, within six (6) months from the date of issuance of the permit, or if the work is not completed within 18 months (permit by contractor) or 24 months (permit by owner) from the date of issuance of the Building Permit. �f Code Compliance Division 2300 Virginia Avenue Ft. Pierce, Fl- 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 http://stl ucieco. gov/ce Date: 18 April 2008 Job Address: 5416 CASSIA DR Received By: dimonb Paid With: CK _.j3uildin9,.` Receipt Paid By: SHIELD OF PROTECTION SYSTEMS, INC Sign: Receipt #: 0000062248 'ermit Number: SLC- 0804-0222 Amount: $130.00 �redit Card Number: Check Number: 6040 2004 FLORIDA BUILDING CODE WORST CASE DESIGN PRESSURE CHART FOR COMPONENTS AND CLADDING per ASCE 7-02 FOR BUILDINGS WITH MEAN ROOF HEIGHT OF 60 FEET OR LESS DESIGN PRESSURES FOR INTERIOR ZONES ("Zone 4") Mean Roof Height Tributary Area (sq. ft) (ft) 10 15 20 25 30 35 40 45 50 15 42.7 41.6 40.8 40.2 39.7 39.2 38.9 38.5 38.3 -46.3 45.2 44.4 -43.8 -43.3 42.9 42.5 42.2 41.9 16 43.3 42.2 41.4 40.7 40.2 39.8 39.4 39.1 38.8 47.0 45.8 45.0 44.4 43.9 43.4 43.1 42.7 -42.4 17 43.9 42.7 41.9 41.2 40.7 40.3 39.9 39.6 39.3 47.6 46.4 45.61 45.0 44.4 44.0 43.6 43.3 43.0 18 44.4 43.2 42A 41.7 41.2 40.8 40.4 40.1 39.7 48.2 -47.0 -46.2 -45.5 -45.0 -44.5 -44.2 -43.8 -43.5 19 44.9 43.7 42.9 42.2 41.7 41.2 40.9 40.5 40.2 -48.7 -47.5 -46.7 -46 44 -44.0 20 45.4 44.2 43.3 42.7 42.1 41.7 41.3 41.0 40. -49.2 -48.0 47.2 46.5 46.0 45.5 45.1 44.8 44. 22 46.3 45.1 44.2 43.6 43.0 .1 41.8 41.5 -50.2 -49.0 -48.1 -47.5 '-46.9 -46.5 -46.1 -45.7 -45.4 24 47.2 45.9 45.0 44.4 43.8 43.3 42.9 42.6 42.2 -51.2 -49.9 -49.0 -48.4 -47.8 -47.3 -46.9 -46.6 -46.2 26 48.0 46.7 45.8 45.1 44.5 44.1 43.6 43.3 42.9 -52.0 -50.8 -49.9 49.2 48.6 48.1 47.7 47.3 47.0 28 49.7 47.4 46.5 45.8 45.2 44.8 44.3 44.0 43.6 -52.8 -51.6 -50.7 49.9 49.4 48.9 48.5 48.1 47.8 30 49.4 48.1 47.2 46.5 45.9 45.4 45.0 44.6 44.3 -53.6 -52.3 -51.4 -50.7 -50.1 49.6 49.2 48.8 48.5 32 50.1 48.8 47.9 47.1 46.5 46.0 45.6 45.2 44.9 -54.4 -53.0 -52.1 -51.4 -50.8 -50.3 49.8 -49.5 49.1 34 50.8 49.4 48.5 47.7 47.1 46.6 46.2 45.8 45.4 -55.1 -53.7 -52.8 -52.0 -51.4 -50.9 -50.5 -50.1 49.7 36 51.4 50.0 49.1 48.3 47.7 47.2 46.7 46.3 46.0 -55.7 -54.4 -53.4 -52.7 -52.1 -51.5 -51.1 -50.7 -50.3 38 52.0 50.6 49.6 48.9 48.2 47.7 47.3 46.9 46.5 -56.4 -55.0 -54.0 -53.3 -52.6 -52.1 -51.7 -51.3 -50.9 40 52.5 51.1 50.2 49.4 48.8 48.2 47.8 47.4 47.0 -57.0 -55.6 -54.6 -53.8 -53.2 -52.7 -52.2 -51.8 -51.5 44 53.6 52.2 51.2 50.4 49.8 49.2 48.8 48.3 48.0 -58.1 -56.7 -55.7 -54.9 -54.3 -53.8 -53.3 -52.9 -52.5 48 54.6 53.1 52.1 51.3 50.7 50.1 49.7 49.2 48.9 -59.2 -57.9 -56.7 -55.9 -55.3 -54.8 -54.3 -53.9 -53.5 52 •55.5 54.0 53.0 52.2 51.5 51.0 50.5 50.1 49.7 -60.2 -58.7 -57.7 -56.9 -56.2 -55.7 -55.2 -54.8 54.4 56 56.4 54.9 53.8 53.0 52.3 51.8 5 L' 50.9 50.5 -61.2 -59.7 -58.6 -57.8 -57.1 -56.6 -56.1 -55.6 -55.3 60 57.2 55.7 54.6 53.8 53.1 52.5 52.0 51.6 51.2 -62.0 -60.5 -59.5 -58.6 -58.0 -57.4 -56.9 '-56.5 -56.1 DESIGN PRESSURES FOR EXTERIOR ZONES ("Zone 5"1 Emma T. Mellinger, P.E 1600 S. Federal Highway. #207 Pompano Beach, A33o62 Mean Roof Tributary Area (sq. ft) Height (ft) 10 15 20 25 30 35 40 45 50 15 42.7 41.6 40.8 40.2 39.7 39.2 38.9 38.5 38.3 -57.2 -55.0 -53.4 -52.1 -51.1 -50.2 49.5 48.9 48.3 16 43.3 42.2 41.4 40.7 40.2 39.8 39.4 39.1 38.8 -58.0 -55.7 -54.1 -52.8 -51.8 -50.9 -50.2 49.5 48.9 17 43.9 42.7 41.9 41.2 40.7 40.3 39.9 39.6 39.3 -58.7 -56.4 -54.8 -53.5 -52.5 -51.6 -50.8 -50.2 -49.6 18 44.4 43.2 42.4 41.7 41.2 40.8 40.4 40.1 39.7 -59.4 -57.1 -55A -54.2 -53.1 -52.2 -51.4 -50.8 -50.2 19 44.9 43.7 42.9 42.2 41.7 41.2 40.9 40.5 40.2 -60.1 -57.8 -56.1 20 45.4 44.2 43.3 42.7 42.1 41.7 41.3 41.0 40.6 60.8 -58.4 -56.7 -55.4 -54.3 -53.4 -52.6 -51.9 -51.3 22 46.3 4.1 44.2 43.6 3. 42.1 41.8 41. 62.0 -59.6 -57.8 -56.5 -55.4 -54.5 -53.7 -53.0 -52.3 24 47.2 45.9 45.0 44.4 43.8 43.3 42.9 42.6 42.2 -63.2 .60.7 -58.9 -57.5 -56.4 -55.5 -54.7 -53.9 -53.3 26 48.0 46.7 45.8 45.1 44.5 44.1 43.6 43.3 42.9 =64.2 -61.7 -59.9 -58.5 -57.4 -56.4 -55.6 -54.8 -54.2 28 48.7 47.4 46.5 45.8 45.2 44.8 44.3 44.0 43.6 -65.2 -62.7 -60.8 -59.4 -58.3 -57.3 -56.5 -55.7 -55.0 30 49.4 48.1 47.2 46.5 45.9 45.4 45.0 44.6 44.3 -66.2 .63.6 -61.7 -60.3 -59.1 -58.1 -57.3 -56.5 -55.8 32 50.1 48.8 47.9 47.1 46.5 46.0 45.6 45.21 44.9 -67.1 -64.5 -62.6 -61.1 -59.9 -58.9 -58.1 -57.3 -56.6 34 50.8 49.4 48.5 47.7 47.1 46.6 46.2 45.8 45.4 -68.0 -65.3 -63.4 -61.9 -60.7 -59.7 -58.8 -58.0 -57.3 36 51.4 50.0 49.1 48.3 47.7 47.2 46.7 46.3 46.0 -68.8 -66.1 -64.2 -62.7 -61.4 -60.4 -59.5 -58.7 -59.0 38 52.0 50.6 49.6 48.9 48.2 47.7 47.3 46.9 46.5 -69.6 -66.8 -64.9 -63.4 -62.1 -61.1 -60.2 -59.4 -58.7 40 52.5 51.1 50.2 49.4 48.8 48.2 47.8 47.4 47.0 -70.3 -67.6 -65.6 -64.1 -62.8 -61.8 -60.9 -60.1 -59.3 44 53.6 52.2 51.2 50.4 49.8 49.2 48.8 48.3 48.0 -71.7 -68.9 -66.9 -65.4 -64.1 -63.0 -62.1 -61.3 -60.5 48 54.6 53.1 52.1 51.3 50.7 50.1 49.7 49.2 48.9 -73.1 -70.2 -68.2 -66.6 -65.3 -64.2 -63.2 -62.4 761.7 52 55.5 54.0 53.0 52.2 51.5 51.0 50.5 50.1 49.7 -74.3 -71.4 -69.3 -67.7 -66.4 -65.3 -64.3 -63.5 -62.7 56 56.4 54.9 53.8 53.0 52.3 51.8 51.3 50.9 50.5 -75.5 72.5 70.4 -68.8 -67.4 -66.3 -65.3 -64.5 -63.7 60 57.2 55.71 54.6 53.8 53.1 52.5 52.0 51.6 51.2 -76.6 -73.6 -71.4 69.8 -68.4 -67.3 -66.3 -65.4 -64.6 General Notes 1 These tables are not valid as a site -specific drawing 2 These tables are only valid when signed and embossed with raised impression seal by Emma T. Mellinger, P.E. 3 No alterations or maridngs on this document are permitted 4 These tables apply to walls and vertical surfaces only. 5 Use of these tables, and the values and coefficients listed herein is to be dictated and verified by the governing building department and permit holder. 6 These tables are intended solely to illustrate design wind pressures as listed. No other warranty or certification is intended or applicable. 7 This document is the work and property of Emma T. Mellinger, P.E., and shall not be reproduced in whole or in part without her express written consent. (954) 784-6991 (954) 781-57o8 fax emma@c5es.com JOB SITE LOCATION: WIND SPEED = 140 MPH. EXPOSURE "C" These tables are valid for the following conditions only: I Wind Speed (3-second just):140 mph. 2 Building Category. II (General Residential and Commercial Construction). 3 Importance Factor. 1.0 4 Exposure Category. C 5 Topographic Factor (Kzt): 1.0 (Flat Terrain) 6 Directionality Factor (Kd): 0.85 For situations requiring Kd=1.0, multiply the values in these tables by 1.18. Verify Kd requirements with local budding official and product approvals before use. 7 Gcpi: +-0.18 8 Enclosed Building Consult an Engineer for any other conditions Instructions 1 Tables show the "worst case" design pressures, with any unknown variable at its critical condition. 2 Tables me valid only for mean roof heights of 60 feet or less. 3 Tables are valid for any roof slope. For reductions for roof slopes less than 10 degrees, consult Engineer for site specific analysis. 4 Calculate the average roof height If average cannot be detemtined, use the peak roof height Round up the roof height to the next highest table value. 5 Calculate the tributary area Qength x height) of the opening in question. Round the tributary area down to the next smallest table value. If the tributary area is unknown, use the most critical value (10 square feet). 6 Area between structural mullions shall be used as tributary area. 7 Determine the Zone (Interior 4, or Exterior 5) of the opening. An opening with any portion closer than distance "a" to a budding comer shall be considered in an Exterior Zone (5), otherwise if all of the opening falls more than distance "a" from a building comer, the opening shall be considered in an Interior Zone (4). 8 Distance "a," as refered to above, shall be calculated as the smaller of 10% of the minimum building width or 40 % of the height, but not less than 3 feet 9 Read the worst case positive and negative design pressures for use as required by governing building department M IIA�AM��I•DADE &KAU " MIAMI-DADE COUNTY, FLORIDA METRO-DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE (BCCO) 140 WEST FLAGLER STREET, SUITE 1603 PRODUCT CONTROL DIVISION MIAMI, FLORIDA 33130-1563 (305) 375-2901 FAX (305) 375-2908 NOTICE OF ACCEPTANCE (NOA) www.miamidade.aov GE Plastics - Polymershapes 1401-A Tampa East Blvd. Tampa, FL 33619 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance; if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: 0.118" Polymershapes Corrugated Storm Panels Shutter APPROVAL DOCUMENT: Drawing No. GEA-0003-1, titled " 3mm Polymershapes Corrugated Storm Shutter", sheets 1 through 3 of 3, prepared by PTC Engineering, Inc., dated November 04, 2005, signed and sealed by Luis R. Lomas, P.E., bearing the Miami -Dade County Product Control Approval stamp with the Notice of Acceptance number and approval date by the Miami -Dade County Product Control Division. MISSILE IMPACT RATING: Large and Small Missile Impact LABELING: Each panel shall bear a permanent label with the manufacturer's name or logo, city, state and the following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply withany section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists of this page 1, evidence submitted page E-1 as well as approval document mentioned above. The submitted documentation was reviewed by Helmy A. Makar, P.E. Q� NOA No. 06-0104.02 v / Expiration Date: 08/03/2011 Approval Date: 08/03/2006 Page 1 GE Plastics - Polymershapes NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED• A. DRAWINGS 1. Drawing No. GEA-0003-1, titled " 3mm Polymershapes Corrugated Storm Shutter", sheets I through 3 of 3, prepared by PTC Engineering, Inc., dated November 04, 2005, signed and sealed by Luis R. Lomas, P.E. B. TESTS 1. Test report on Large Missile Impact Test, Cyclic Wind Pressure Test, and Uniform Static Air Pressure Test of 0.118" Polymershapes Corrugated Storm Shutters, prepared by Certified Testing Laboratories, Report No. CTLA 1445W-1, dated November 08, 2005, signed and sealed by Ramesh Patel, P.E. C. CALCULATIONS 1. Anchor Calculations and details for 0.118" Polymershapes Corrugated Storm Shutters, dated November 29, 2005, pages I through 4 of 4, prepared by PTC Engineering, Inc., signed and sealed by Luis R. Lomas, P.E. D. QUALITY ASSURANCE 1. By Miami -Dade County Building Code Compliance Office. E. MATERIAL CERTIFICATIONS 1. Lexan XL 10 sheet Product Data Sheet. d w6z,-� W. Helmy A. Makar, P.E. Product Control Examiner NOA No. 06-0104.02 Expiration Date: 08/03/2011 Approval Date: 08/03/2006 E-1 A FILL' COPU Phasel Floor I Opens I Trap IPanels Length I Vertical I BO I I Comments 1 1 1 L&R 44 25 ACCORDION 1 1 2 L&R 81 25 ACCORDION 1 1 3 L&R 66 83.75 ACCORDION 1 1 4 L&R 81 37 ACCORDION 1 1 5 L&R 35.5 83.75 IACCORDION 1 1 6 L&R 431 25 ACCORDION 1 1 71 L&R 55 47 ACCORDION 1 2 81 1.5 23 GE CLEAR PANEL 1 2 9 2 21 GE CLEAR PANEL 1 2 10 2 21 GE CLEAR PANEL 1 2 11 1 24 IGE CLEAR PANEL 1 2 12 11 24 GE CLEAR PANEL 1 12 13 L&R 66.5 34.5 ACCORDION 1 2 1 141 L&R 34.5 84.25 ACCORDION 1 12 1 151 2 45 GE CLEAR PANEL 1 12 1 161 L&R 34 37 ACCORDION 142.15 JACCORDION SQ FT 1ST FL 49.7 JACCORDIONSQFT2NDFL 27.55 ICLEAR PANEL SQ FT 2ND FL E SALES ORDER # TYPE B3402 ACCORDIAN SOD = SLIDING GLASS DOOR SHD = SINGLE HUNG DOOR DD = DOUBLE DOOR BO = BUILDOUT S\L = SIDELITE B\G = BUTT GLASS G\B = GLASS BLOCK nerile JOB NAME ADDRESS _ _ CITY _ROBERT WILLIAMS' 5416 CASSIA DRIVE FORT PIERCE, FL 349825 ` DEVELOPMENT SUBDIVISON LOT BLOCK = j` JOB# DATE 4/1712008 SQUARE FT. No N A& r r I �-- 44.00" MAX. WIDTH -j EXTERIOR ELEVATION 3MM CORRUGATED 60" HEIGHT 17.750" TRIM R.250" I )" MAX. 1 6.562" 6.563" O.C. MAX. 125" r CORRUGATED PANEL DETAIL MATERIAL: LEXAN XL PER GE N.O.A. 03-1210.04 GENERAL NOTES: 1) THIS SHUTTER SYSTEM IS DESIGNED AND INSTALLED IN ACCORDANCE TO THE 2004 FLORIDA BUILDING CODE AND MEETS "HVHZ" ZONES REQUIREMENTS. 2) GE ADVANCED POLYMERS CLEAR STORM PANELS SHALL BE MADE OF GE U.V. RATED LEXAN XL-10 SHEET, BY GE N.O.A. 03-1210.04 3) ALL BOLTS AND WASHERS SHALL BE GALVANIZED OR STAINLESS STEEL WITH A MINIMUM TENSILE STRENGTH OF 60 K.S.I. UNLESS MADE OF RUBBER. 4) TOP AND BOTTOM DETAILS SHOWN MAY BE INTERCHANGED AS FIELD CONDITIONS DICTATE, PANELS MAY BE MOUNTED HORIZONTALLY WHERE APPLICABLE. 5) PANELS SHALL BE FASTENED ACCORDING TO FASTENER MANUFACTURER'S INSTALLATION SPECIFICATIONS AND AS SHOWN HEREIN. 6) EMBEDMENT IS THE DEPTH INTO CONCRETE MASONRY UNIT (CMU), CONCRETE OR WOOD FRAMING MEMBER AS NOTED AND DO NOT INCLUDE STUCCO OR OTHER FINISHES. 7) STORM PANEL ANCHORAGE TO SUBSTRATE USE ONE 1 /4" DIAMETER ELCO PANELMATE OR 1 /4" DIAMETER TAPCON SG WITH 1 /4-20 WING NUT AND RUBBER WASHER LOCATED 2.5" MAXIMUM FROM EACH END AND ON 6 1 /2" MAXIMUM ON CENTER THEREAFTER. A1--- — — .."' -1177//1133/-066 SYM REVISION 1 DATE ITEM # ITEM DESCRIPTION 1 3 MM (0.118") CORRUGATED PANEL 17-3/4" 2 1 /4" DIA. ELCO PANEL MATE MALE FASTENER 3 1 /4-20 S.S. WING NUT 4 1/4 X 1-1/4" X 1/8" RUBBER WASHER 5 1 /4" TAPCON SG (ITW BUILDEX) 1.76" TRIM 2.000" 128"' MINIMUM DESIGN MAX PANEL SEPARATION PRESSURE LENGTH FROM (PSF) (IN) GLASS (IN) ±50.0 60" 4" Luis R. Lomas P.E. FI rida No. 62514 Y OC 3� go to C)p CD CLUX cl C30 in �Uco �.2t in rei L_ in � a c.0 z eu Cr cis JV' cocn�ocscz w LU lz¢ aiWacmcs, Appmed 2a ej:,aplyle g n t4i Elk >aiasa- 0 8 03 Z no b i�Rctai €7iiee rt�!�u rv' GE PLASTICS - POLYMERSHAPES 1401-A TAMPA EAST BLVD TAMPA, FL 33619 TITLE:3MM POLYMERSHAPES CORRUGATED STORM SHUTTER ELEVATIONS AND ANCHOR DETAILS PREPARED BY: DRN: DATE: J.M. 1 1 1 /04/05 PTC Engineering, Inc. �' 2361 S.E. Seafury Lone NmIIIIIIIIIIIIr Port St. Lucie, FL 34952 PTC ENGINEERING, INC. FBPE Certificate of Authorization No. 25935 Phone 772.398.4639 Fox 772,398.4654 NTS GEA-0003-1 SHEET: A 1 OF 3 1 1/4" MIN. EMBEDMENT CONCRETE OR MASONRY 1 1/2" MIN. STRUCTURE BY OTHERS EXTERIOR SHEATHING EMBEDMENT BY OTHERS INTERIOR FINISH AV BY OTHERS CAULK BETWEEN SCREW CAULK BETWEEN SCREW a 2 SEE NOTE 7 FOR SPACING & EXTERIOR SHEATHING & EXTERIOR FINISH 5 OF ANCHORS AND TYPE 2X FRAMING BY OTHERS I •. a a I - I I I 2 I 2" MIN 3 4 i 1 SEE NOTE 7 FOR SPACING 5 OF -ANCHORS AND TYPE EDGE DISTANCE EXTERIOR i EXISTING GLASS EXTERIOR FINISH 3 4 I BY OTHERS MAX. PANEL 1 HEIGHT I I I I I I 4" MIN. MAX. I EXISTING GLASSPANEL i N I HEIGHT i A 1 VERTICAL/HORIZONTAL INSTALLATION I EXTERIOR I 2 WOOD FRAMING I SEE NOTE 7 FOR SPACING 2" MIN. OF ANCHORS AND TYPE 4" MIN. CONCRETE OR MASONRY EDGE DISTANCE 2" MIN. SEPARATION STRUCTURE BY OTHERS EDGE DISTANCE j 5 2 EXISTING GLASS EXTERIOR FINISHI BY OTHERS 1 1/4" MIN. EXTERIOR FINISH �- ° c .. MIN. ' ]/ BY OTHERS 4" MIN. ° ' , ` EMBEDMENT SEPARATION 1 EXTERIOR FINISH EMBEDMENT � �- BY OTHERS CONCRETE OR MASONRY STRUCTURE BY OTHERS SEE NOTE 7 FOR SPACING ------------------------- --------------------------------- --- CAULK BETWEEN SCREW I OF ANCHORS AND TYPE - 2" MIN. & EXTERIOR SHEATHING EDGE DISTANCE MAX. PANEL WIDTH SEE NOTE 4 FOR MOUNTING F SEE NOTE7 FOR SPACING OPTIONS AND LIMITATIONSOF ANCHORS AND TYPE 3 4 o3e Zoo6 EXTERIOR CAULK BETWEEN SCREW & EXTERIOR FINISHHORIZONTAL INSTALLATION2 MASONRYo, CONCRETE OR MASONRY 1 1/4" MIN. STRUCTURE BY OTHERS EDMENT Luis R. Lomas P.E. GE PLASTICS — POLYMERSHAPES A VERTICAL INSTALLATION Florida No. 62514 1401—A TAMPA EAST BLVD 2 MASONRY TAMPA, FL 33619 TITLE:3MM POLYMERSHAPES CORRUGATED STORM SHUTTER V111/ HORIZONTAL & VERTICAL ANCHOR DETAILS / PREPARED BY- DRN: DATE: J.M. 11 04 05 PTC Engineering, Inc. �' SCALE: DWG. NO: 2361 S.E. Seafury Lone NTS GEA-0003-1 A REVISED COMPANY ADDRESS 7/13/06 R.L. Port St. Lucie, FL 34952 PTC ENGINEERING, INC. REV: SHEET: FBPE Certificate of Authorization No. 25935 Phone 772.398.4639 Fox 772.398,4654 Q 2 OF 3 NNEENMEMONim SYM REVISION DgTE BY � p • . ry6 � � � � .• ay '.v ; �'•. •y � vY . �y . 'v:• . _ :'v • ,ve • ..v .-ate e:' • �va c .'.. t gyp'° ° •.ve .. � �_t.... P L'p - :v`' o �'. Ly.._°ay. 9. .v. �... _ .• r •. v. q .. 6.50" MAX. O.C. MAX. PANEL WIDTH SEE NOTE 7 FOR SPACING OF ANCHORS AND TYPE TOP VIEW DIRECT MOUNT 'INSTALLATION IN MASONRY/CONCRETE AND STORM PANEL ASSEMBLY DETAILS SYM ©T© 1/4" ELCO PANELMATE MALE FASTENER 1 /4" TAPCON SG 0 � ' r 1 /4-20 WING NUT EO RUBBER WASHER OF 60 DUROMETER RUBBER 1-1 /4' O.D. X 1 /4" I.D. X 1 /8" THICK. MUST BE USED AT ALL CONNECTIONS USING HOLE OR KEY HOLE OF STORM PANEL t@g➢j med V; &r%raP yfAZ WWI fe Luis R. Lomas P.E. GE PLASTICS — POLYMERSHAPES Flo, Ida No. 62514 1401—A TAMPA EAST BLVD �. / TAMPA, FL 33619 TITLE: POLYMERSHAPES CORRUGATED STORM SHUTTER DIRECT MOUNTING & SECTION DETAILS PREPARED BY: RN: DATE: J.M. 1 1 /04/05 PTC Engineering, Inc. �'�SCALE: DWG. NO: 2361 S.E. Seofury Lane NTS GEA-0003-1 ADDRESS 7/13/06 R.L. Port St. Lucie, FL 34952 PTC ENGINEERING, INC. REV: SHEET: REVISION DATE BYFBPE Certificate of Authorization No, 25935 Phone 772.398.4639 Fax 772.398.4654 A 3 OF 3 BCIS Home Log In j Hot Topics i Submit Surcharge Stats & Facts ! Publications I FBC Staff B Product Approval USER: Public User • Affairs U2, Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL4455 Application Type New Code Version 2004 Application Status Approved • Comments Archived Product Manufacturer ARMOR MANUFACTURING, INC. . Address/Phone/Email 1339 SW SOUTH MACEDO BOULEVARI PORT ST. LUCIE,• FL 34983 (772) 878-7332 welovej.esus4@cs.com Authorized Signature Vladimir Knezevich , KAEng@aol.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Certification Agency Referenced Standard and Year (of Standard) Equivalence of Product Standards Shutters Accordion Certification Mark or Listing Miami -Dade BCCO - CER Standard PA 201, PA 202, PA 203 e Certified By r n Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Method 1 Option A 04/28/2005 04/28/2005 05/31/2005 06/29/2005 Summary of Products FL # 7IModel, Number or Name Description 4455.1 HT-100 Accordion Shutter Extruded Aluminum Alloy and centermates. Limits of Use (See Other) Certification Agency Ce Approved for use in HVHZ: Installation.Instruction Approved for use outside HVHZ: PTID 4455 I 0501_2.701. Impact Resistant: Verified By: Design Pressure: +/- Other: This product has a Miami -Dade County,. Building.Code Compliance Office, Product Control Division, NOA. No. 05-0127.01 Design Wind Loads for each opening or glazing on a structure must be determined before 'proceeding with the use of this product drawing. This product may be used in the High Velocity Hurricane Zone (HVHZ). The maximum gap between the slat and the sill is 0.25 inches. Back Next DCA Administration Department of Community Affairs Florida Building Code Online Codes and Standards 2555 Shumard Oak Boulevard Tallahassee, Florida 32399-2100 (850) 487-1824, Suncom 277-1824, Fax (850) 414-6436 © 2000-2005 The State of Florida. All rights reserved. Copyrght_and Disd, Product Approval Accepts: 'c�.hFck E Y�rlblg� ' Saturad VEN�f Y► MIAMI-DAM MIAMI-DADE COUNTY, FLORIDA METRO-DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130-1563 NOTICE OF ACCEPTANCE (NOA) (305) 375-2901 FAX (305) 375-2908 Armor Manufacturing, Inc. www.buildinffcodeonfine.com 1339 S.W. Macedo Boulevard Port Saint Lucie, Florida 34983 SCOPE: This NOA is being issued under the applicable rules and regulations. governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: HT-100 / Aluminum Accordion Shutter APPROVAL DOCUMENT: Drawing No. 06-303, titled "HT-100 Aluminum Accordion Shutter", sheets I through 7 of 7, prepared by Thornton-Tomasetti Group, dated Sept. 14, 2005, last revision #0 dated September 14, 2005, signed and sealed by V. J. Knezevich, P.E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Division. MISSILE IMPACT RATING: Large and Small Missile Impact LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and the following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,,for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises & renews NOA # 0"127.01 and consists of this page 1, evidence submitted pages E-I & E-2 as well as approval document mentioned above. The submitted documentation was reviewed by Helmy A. Mahar, P.E. NOA No 06-0221.03 Expiration Date: 10/23/2011 o S10 4�2oo( Approval Date: 05/04/2006 Page 1 Armor Manufacturing Inc NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED . 1. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL #01-0917.01 A. DRAWINGS 1. Drawing No. 01-814, titled "HT100 Accordion Shutter" prepared by Knezevich & Associates, Inc., dated July 23, 1996, last revision #6 dated June 10, 1999, sheets 1 through 6 of 6, signed and sealed by V.J. Knezevich, P.E. B. TESTS L See Association's generic approval # 99-0036. C. CALCULATIONS 1. See Association's generic approval # 99-0036. D. MATERIAL CERTIFICATIONS L See Association's generic approval # 99-0036. E. STATEMENTS I. Release letter issued by the Hi -Tech Shutter Group, Inc., dated September 13, 2001, certifying this product to meet the criteria of product tested and approved, and allowing Armor Manufacturing, Inc. to use the test results approved under Miami - Dade County Approval No. 99-0036, signed by Mr. Frank Cornelius. 2. Acknowledgment letter by Armor Manufacturing, Inc., not dated, signed by Mr. W. Rick Whitten. 3. - Letter by Knezevich & Associates, Inc., dated September 12, 2001, certifying that the drawing (No. 01-814) prepared for Armor Manuffacturing, Inc., signed and sealed by VJ. Knezevich, P.E., is engineering wise identical to Hi -Tech Shutter Group, Inc. Association generic drawing (No. 96-168). 4. Acceptance Letter issued to Mr. W. Rick Whitten on October 2, 2001 and returned signed by Mr. W. Rick Whitten on October 15, 2001, indicating to please issue the proposed Notice of Acceptance as submitted and reviewed. 2. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL #05-0127.01 A. DRAWINGS 1. Drawing No. 04-401, titled " HT-100 Accordion Shutter ", sheets 1 through 7 of 7, prepared by Thornton-Tomasetti Group, dated October 17, 2002, last revision #1 dated December 4, 2002, signed and sealed by V J. Knezevich, P.E. B. TESTS 1. See Association's generic approval under 02-0799. C. CALCULATIONS 1. See Association's generic approval under 02-0799. 13elmy A. Makar, P. E. Product Control Examiner NOA No 06-0221.03 Expiration Date: 10/23/2011 E-1 Approval Date: 05/04/2006 Armor Manufacturing, Inc NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED D. QUALITY ASSURANCE 1. By Miami -Dade County Building Code Compliance Office. E. MATERIAL CERTIFICATIONS L See Association's generic approval under 02-0799. F. STATEMENTS 1. Statement letter of conformance by Thornton-Tomasetti Group, dated January 17, 2005, signed and sealed by V. J. Knezevich, P.E. 3. NEW EVIDENCE SUBMITTED A. DRAWINGS I. Drawing No. 06-303, titled "HT-100 Aluminum Accordion Shutter", sheets I through 7 of 7, prepared by Thornton-Tomasetti Group, dated Sept. 14, 2005,' last revision #0 dated September 14, 2005, signed and sealed by V. J. Knezevich, P.E B. TESTS 1. See Association's generic approval under 05-0321. C. CALCULATIONS 1. See Association's generic approval under 05-0321. D. QUALITY ASSURANCE 1. By Miami -Dade County Building Code Compliance Office. E. MATERIAL CERTIFICATIONS 1. See Association's generic approval under 05-0321. F. STATEMENTS 1. Release letter issued by the Hi -Tech Shutter Group, Inc., dated January 11, 2006, certifying this product to meet the criteria ofproduct tested and approved, and allowing Armor Manufacturing, Inc. to use the -test results approved under Miami -Dade County Approval No. 05-0321, signed by Mr. Frank Cornelius. 2. Acknowledgment letter by Armor Manufacturing, Inc. dated February 06, 2006, signed by W. Richard Whitten. 3. Letter by Thornton-Tomasetti Group, dated January 11, 2006, certifying that the drawing (No. 06-303) prepared for Armor Manufacturing, Inc., signed and sealed by Mr. V. J. Knezevich; P.E., is engineering wise identical to Hi-Tech's generic drawing (No. 05-509). Pelmy A. Makar, P. E. roduct Control Examiner NOA No 06-0221.03 Expiration Date: 10/23/2011 E-2 Approval Date: 05/04/2006 O E CL to 0 LO 0 LO 0 to 0 O 0 0 c U t1 - :055" t12 = .076' HEADER-CLG. OMOUNTED SCALE: HALF SIZE 2.420" 048" '966" .875 83' 0 Ln N O O `n 0 t N t2 t2 It 2 �11 N t N �O m m 6110 N n rn 1 111'9 3)a-}1 0 Ln t1 = .O 5_5_'_l N t2 = .076" HEADER -WALL MOUNTED SCALE: HALF SIZE / 3.993' 52" 4.478" + 8a ADAPTER SLAT SCALE: HALF SIZE N 52" N 45 4.078" 4.534" OTYP. SLATS SCALE: HALF SIZE GENERAL NOTES: 1. THESE APPROVAL DOCUMENTS REPRESENT A SHUTTER SYSTEM ANALYZED WITH THE PROVISION SET FOR THE ISSUANCE OF A NOTICE OF ACCEPTANCE (NOA) BY MIAMI-DADE COUNTY PRODUCT CONTROL DIVISION FOR THE FLORIDA BUILDING CODE, 2004. 2. APPROVAL DOCUMENTSNNOOINCREASE INTALL OWABLETSTRESS WASSUSED INHTHE FASTENER ANALYSIS. 3. DETERMINE THE POSITIVE AND NEGATIVE DESIGN LOADS TO USE WHEN REFERENCING THESE DOCUMENTS IN ACCORDANCE WITH THE GOVERNING CODE AND GOVERNING WIND VELOCITY. FOR WIND LOAD CALCULATIONS IN ACCORDANCE WITH THE FLORIDA BUILDING CODE 2004 A DIRECTIONALITY FACTOR OF Kd =0.85 SHALL BE USED. 4. THESE APPROVAL DOCUMENTS ARE GENERIC AND DO NOT INCLUDE INFORMATION FOR SITE -SPECIFIC APPLICATION OF THIS SHUTTER SYSTEM. S. USE OF THESE APPROVAL DOCUMENTS SHALL COMPLY WITH CHAPTER 611315-23 OF THE FLORIDA ADMINISTRATIVE CODE. 6. THESE APPROVAL DOCUMENTS ARE SUITABLE TO BE APPLIED BY THE CONTRACTOR .048" 3.840" 125" 1.840" OCENTER MATE 1 SCALE: HALF SIZE 2 0 o CD } _ o 0 1 N m a= ' Ft3 :D YP.2)o 055' (TYP.) N N O: N O% N N 1.533" -14 .055" - .500" OADJ. SILL-BOT. SCALE: HALF SIZE 1.533" 090- END SLAT 68 SCALE: HALF SIZE .641" 1.250" 136" 1.250" .985" 0 .250" 3.283' .050" ALTERNATI ADJ. SILL- OT. OFLAT END SLAT SCALE: HAL SIZE 7 SCALE: HALF SIZE 3.267" '63 I.D. 0 30" O.D. N .165285"O.D. I.D. " in .060" rn 1.039" N 00 ul 6 .060" m N 60" JI 134-5'* � UCD � Z 'U w00 01Lp O Z_ C3 -1 or' rn cc ocb00rc°°:1 m 0 O � 0U.0U �m U Q W am O7 Q IL a V 1, N Z Z Q 3t"ZX Ol 1pp=, � Q 0 m O d ^ a. 9a CENTER MATE 1 (w/LOCIONG ROD) CENTER MATE 2 (w LOaaNC Roo) I vi SCALE: HALF SIZE SCALE: HALF SIZE prpl, II FL Ucel R NIJL_l IVu l Gvlr 1 C rRVI-1 I fIG LUIVUI I IlJJND UC 1 AILCU STAINLESS STEEL HEREIN AND THE CONTRACTOR VERIFIES THAT THE EXISTING STRUCTURE DOES 375"y, NOT DEVIATE IN EITHER FORM OR MATERIAL FROM THE STRUCTURAL SUBSTRATES ASSEMBLY 375" 15' DETAILED HEREIN. o .320"0 HOLE 7. ANY MODIFICATIONS OR ADDITIONS TO THESE APPROVAL DOCUMENTS WILL VOID p m �r-�1 i i { �485" 15" THE APPROVAL DOCUMENTS. o NYLON WHEE I I o I I I I RIVETED IN 8. WHEN THE SITE CONDITIONS DEVIATE FROM THESE APPROVAL DOCUMENTS, THE nj N PLACE I I � I I o u BUILDING OFFICIAL MAY ELECT ONE OF THE FOLLOWING OPTIONS: 058•• I I IIC)A) REQUIRE THAT SITE SPECIFIC DOCUMENTS BE PREPARED, SIGNED DATED AND I Im 1.1001, 251" I ISEALED BY A LICENSED ENGINEER OR REGISTERED ARCHITECT H%HICH DETAIL I I234" AND JUSTIFY THE DEVIATION. SAID DOCUMENTS SHALL BE SUBMITTED TO THE 230" MAX. PRODUCT ENGINEER FOR REVIEW AS A CONDITION TO THE BUILDING OFFICIAL MAX. GRANTING HIS/HER APPROVAL. 2" MIN.-5" MAX. TYP. AT EVERY OTHER MAX INSIDE JOINT AT TOP. TOP BOTTOM CHARIER B) REQUIRE THAT A ONE-TIME SITE SPECIFIC APPROVAL BE APPLIED FOR AN SECURED FROM THE MIAMI-DADE COUNTY PRODUCT CONTROL DIVISION. DANGLE DROLLER ASSEMBLY ®BUSHINGS WHEN THE SITE CONDITION DEVIATIONS OCCUR WITHIN THE HIGH VELOCITY HURRI ANE 11 SCALE: HALF SIZE 12 SCALE: HALF SIZE 2 SCALE: FULL SIZE ZONE AREAS, ONLY OPTION "B" SHALL BE ACCEPTED BY THE BUILDING OF IAL. 9. EACH SHUTTER ASSEMBLY SHALL BE PERMANENTLY LABELED AS FOLLOWS: ARMOR MANUFACTURING INC. 6 .040 .956" 17 pp5fi�� .222' #050 m In00 rm In 1.400" 1/8- THICK STAINLESS STEEL 13 INSERT 14 LOCKING ARM SCALE: HALF SIZE SCALE: HALF SIZE PORT SAINT LUCIE FLORIDA tllq 00 . 10 50" MIAMI-DADE COUNTY PRdDUCiAPPROVED ;1 - 360" 80" 435" R REVISE ID �•472" I.D. N t 375" R PRODUCT REVI �_Du 10. ALL SHUTTERS SHALL HAVE A LOCKING MECHANISM AT CENTER OR SIDE CLOSURE -.612" O.D. t 0% c- E .135" R as cumiaiyil -whah the f:®TSIs WITHIN 18' OF CENTER (VERT.). LOCKING MECHANISM SHALL BE LOCKED TO PROVIDE 158" 44 tl �, HURRICANE PROTECTION. k o i O Baidia�BC©W2 f .505" R Acceplaace NvO _022 .03 11. STORM SHUTTER EXTRUSIONS SHOWN SHALL BE 6063-T6 ALUMINUM ALLOY, U.O.N. 00 o Expirr988rr i)aa� Zoe( 12. ALL SCREWS AND BOLTS TO BE 2024-T4 ALUMINUM ALLOY STAINLESS STEEL, �t I 211' t2 t2 2 I211" 150" 315" R 0.. POP RIVETSITO BE 3/16 015052 MINIMUM L ALUM. ALI TENSILE 0•NTRENGTI) OF 60 K.S.L. U.O.N. t51� 83' 8 8 $�sy 1.350" 500" t1 - .055" t = .200" 13. TOP AND BOTTOM DETAILS MAY BE INTERCHANGED AS FIELD CONDITIONS REQUIRE. t2 = .07 f09i i)ad ¢it$:@9131R1 Dividen 14. FLOOR TRACKS MAY � REMOVABLE AT NON -STACKING LOCATIONS. USE (OONAL) WALKOVER SILL LOCKING ARM ALIGNMENT INSIDE HANDLE REMOVABLE ANCHORS SUCH AS POWERS CALK -IN ANCHORS. 15 OTHIS SHUTTER FFICE, PATENT NOES IS PATENTED WITH THE U.S. PATENT AND TRADEMARK 15 LOCKING CLIP 16 FLOOR MOUNTED 17 BUSHING (NYLON) 1$ SHIM (NYLON) SCALE: HALF SIZE SCALE: HALF SIZE SCALE: HALF SIZE SCALE: HALF SIZE N 0 2006 0 c O Ln - i u1 �Z O s O -< N na r 13 O O drawing no. 06-303 sheet 1 of O E o. r 0 0 di 0 F N N z� O U - w V) w Z w Q � a 9 VARIES — NO LIMIT OR BELOW CENTER E GENERAL NOTE 10) TYPICAL ELEVATION N.T.S. SHUTTER SEPARATION FROM GLASS. (SEE SCHEDULE ASTENER a 24" O.C. SHEET DISTANCE TO BE SEE ANCHOR SCHEDULE D FROM BACK OF MEASURED OR ANY ACCEPTABLE SHUTTER BLADE OR FROM ,NCHOR). . HANDLE WHEN MOUNTED INSIDE. (TYP.) IjJTTS� I E CI=OSURE SHIf�AN LE W/ SINGLE ARM LOCKING MECHANISM AT CENTER OR SIDE OF SHUTTER. LOCK MAY BE INSTA ON INSIDE OR 0 DE OF SHUTTER TYPICAL PLAN VIEW SCALE: 3" = 1'-0" 3/4" MIN. STENER SCHEDUI � . 1-1/2" MAX. S 1" x 1" x 1/8" ALUM. ANGLE W/ 3/16"0 POP RIVETS @ 6" O.C- USED WITH PIECES (SAND LOCKING PIN SCALE: 1-1/2" = T-0" FASTENER Call 24" O.C. (SEE ANCHOR SCHEDULE FOR ANY ACCEPTABLE ANCHOR). EXISTING GLASS - (TYP.) 6-1/2" iSSEF1BLY OPTIONAL ACCESS HOLE EXISTING STRUCTURE j OPTIONAL' \-JOINT BETWEEN �� SEE SECTION B ON SHEET 3 a DRILL 5/8"0 HOLE FROM REMOVABLE AND BOTTOM OF EXTRUSION O FOR COMPLETE INFORMATION BEFORE ASSEMBLY FOR FIXED SILL CS CONNECTION TYPE a TRUSS HEAD BOLT (TYP.) REFER NCEF N CHOR MAX.:� SPACING E ,0 PIAN VIEW SECTION S c REMOVABLE FLOOR TRACK DETAIL SCALE : 3"= 1'— 0" SINGLE ARM LOCKING MECHANISM AT CENTER NYLON OR SIDE OF SHUTTER. HANDLE LOCK MAY BE INSTALLED ON INSIDE OR OUTSIDE OF SHUTTER 2-1/4' (DOES NOT REPLACE SINGLE ARM LOCq SINGLE ARM LOCK OPTIONAL CLOSER HANDLE N.T.S. N.T.S. r-SINGLE ARM LOCKING IMECHANISM AT CENTER NYLON OR SIDE OF SHUTTER. LOCK MAY BE INSTALLED ON INSIDE OR OUTSIDE OF SHUTTER HANDLE 2-1/4- JC SISINGLE ARM 1.000 SINGLE ARM LOCK OPTIONAL CLOSER HANDLE N.T.S. N.T.S. " MI FASTENER P 24" O.C. (SEE ANCHOR SCHEDULE FOR ANY ACCEPTABLE ANCHOR). U —CARRIER BUSHING qD 12 i7ll6" O.D. 0.63" LONG NYLON TOP BUSHING 2 II 8 #10 x 2" SMS. MANUFACTURED FROM #410HT OR 18-8 STAINLESS W/ XYLAN 5200 FLUOROCARBON STEEL W/ XYLAN 5200 FLUOROCARBON COATING & .460"0 x .050" THICK 300 SERIES STAINLESS STEEL WASHER (TYP. TOP & BOTTOM) -7 MIN. SHUTTER SEPARATION FROM GLASS. (SEE SCHEDULE SHEET 5). DISTANCE TO BE MEASURED FROM BACK OF SHUTTER BLADE OR FROM HANDLE WHEN MOUNTED INSIDE. (TYP.) 9a SINGLE ARM LOCKING MECHANISM AT CENTER OR SIDE OF SHUTTER. LOCK MAY BE INSTALLED ON INSIDE OR OUTSIDE OF SHUTTER SCALE: 3" = 1'-0" 3/4" MIN. E FASTENER SCHEDU �1-1/2" MAX. PLAN VIEW I" x 1" x 1/8" 3/16"0 POP X 3/8" O.D. x 0.90" LONG NYLON BOTTOM BUSHING 2@ '--#10 x 3" SMS. MANUFACTURED FROM #410HT STAINLESS STEEL W/ XYLAN 5200 FLUOROCARBON COATING & .460"0 x .050" THICK 300 SERIES STAINLESS STEEL WASHER (TYP. TOP & BOTTOM) SCREW BUSHING & ROLLER/ BUSHING ASSEMBLY SCALE: HALF SIZE OPTIONAL PLAN VIEW SCALE: 3" = T-0" FASTENER 0 24" O.C. (SEE ANCHOR FOR ANY ACCEPTABLEE ANCHOR). EXISTING GLASS — 6-1/2" 55E LY OPTIONAL LOCATION /-CS CONNECTION TYPE REFERENCE ANCHOR SCHEDULE FOR MAX. SPACING EXISTING STRUCTURE JOINT BETWEEN \-SEE SECTION L ON SHEET 4 REMOVABLE AND FOR COMPLETE INFORMATION FIXED SILL C4 CONNECTION TYPE REFERENCE ANCHOR SCHEDULE FOR MAX. SPACING SECTION T OPTIONAL REMOVABLE FLOOR TRACK DETAIL SCALE: 3"= V— 0" MI � _ a z ruin i �Q 20 ,E V 000 V ` 5e a .N 2 p :iNU 1- _ c vs ov ar 0 = W EU w you s0 } 'o'M o m n^ y N Lj z vFi L U ov m1— U H U m z X01 - v O Wmmm z -1 ar 0! 0 00Mb0 O m0 U 0 -CD IL W I- �-rN ao Z i,rr a 3~zx IM U)(L tL 0 co F —0 Q a' V.J. Me Professional FL License No.; J N 0 2006 �I Fcal, Ac���a�- .•.�o6_o2Zl.Q3 Division draMig no. 06-303 sheet 2 of 7 N .a 0 -0 0 Ea m N to 0 Ln 0 co 04 0 0 0 c 0 U 2 EXISTING CONCRETE, MASONRY OR WOOD STRUCTURE. SEE ANCHOR SCHEDULE, TYP. C2 CONNECTION TYPE �B REFERENCE ANCHOR SCHEDULE FOR MAX. SPACING :. ROLLER ASSEMBLY 1? 1/2'[ TYP. EVERY OTHER PIN 1/4" MAX: EXISTING CONCRETE, MASONRY OR WOOD STRUCTURESEE EXISTING CONCRETE, MASONR OR WOOD STRUCTURE. SEE . ANCHOR SCHEDULE, TYP. 7 ANCHOR SCHEDULE, TYP.— Q a n.w SEE TABLE lnJ 8 � no G qDOOR 3Q OR SEE TABLE 2 pF- J 3/16"0 POP RIV q F- OR DOOR = Q� OR #12 TEK SCRE o Cal 6" O.C. (TYP.) in aw @& 5O X mu ASSEMBLY- Q win 1" x 1" x 1/8" z w ALUM. ANGLE W/ 3/16"0 POP I9� z r 1/4" MAX. RIVETS (la 6" O.0 - C2 CONNECTION TYPE REFERENCE ANCHOR SCHEDULE FOR MAX SPACING 5/8" MAX. OWALL MOUNT SECTION SCALE: 3" = 1'-0" EXISTING CONC SONRY CTURE. SEE ANCHOR SCHEDULE, TYP. \ C3 CONNECTION TYPE REFERENCE ANCHOR SCHEDULE FOR MAX. SPACING BUT DO NOT EXCEED 6" SPACING w 11 CONT7 CONT _�1/2" 1/2" 11 CONT.i1TWO1/4-20 MACHINE BOLTS W/ NUT OR 014 TEK SCREW @ 12" O.C. (TYP., TOP & BOTTOM) SEE TABLE 2 OR DOOR ALT. ANGLE LEG DIRECTION. REVERSED ANGLE LEG MAY BE FROM ONE ANGLE OR FROM BOTH ANGLES (TYP.). C1 CONNECTION TYPE REFERENCE ANCHOR SCHEDULE FOR MAX. SPACING BUT DO NOT EXCEED 6" SPA NG /2„ 11 CONT. ' 1/ CONT. "-(11)CONT. MBED. 5/8" MAX. C4 CONNECTION TYPE REFERENCE ANCHOR SCHEDULE FOR MAX. SPACING 1/4" MAX. EDGE z� DIST. Qw J w waco L N3F- = ZOW in Qom_ Q NQo ORq DOD Xu Q� (al 6" O.C. (TYP.) L-1/4" MAX. Lli OPTIONAL FASTENE LOCATION IN LIEU OF SUPPORT - STAGGE 11 CONT. - FOR LARGER SPANS E TWO 2" x 5" AL. ANGLES EXISTING CONCRETE, MASONRY a.' u; (SEE SCHEDULE 1 TYPE C) C2 CONNECTION TYPE s; OR WOOD STRUCTURE. SEE ANCHOR SCHEDULE, TYP. ;3 REFERENCE ANCHOR C1 CONNECTION TYPE SCHEDULE FOR MAX. 2" x 2" x .050" ALUM. TUBE REFERENCE ANCHOR SPACING BUT DO NOT Mg TYP. TOP & BOTTOM ;. SCHEDULE FOR MAX. EXCEED 8-1/2" SPACING SPACING 1OT/4-20 MACHINE BOLT W/ UT (� 12" O.C. (TYP., TOP ;a — 1/2" w I & BTOM) 0 Y O In 1/4" w c 1/4I'm AX. MAX. ='t z z zA- zQ` Q aw Q aw a tnJ SEE TABLE 2 N SEE TABLE 2 N a 3a 3Q LI pF- w o F- OA ~ Jw O G q� = OR F_ 3-3/4" MA DOOR X� 3-3/16" = Xp qqj�, qq��GG��EE X Xu MAX. X Fu (,EPD)IRECTION Q WV) Q wln ►`I n n r ' 1/4" Lu 1-:=3: MAX. p 1., 1/4" �� 1 I JTOP & BOTTOM w , n /..,MAX. CS CONNECTION TYPE I ANCHOR 1/4" OFF CENTER�RIS/8" c>m svmymem:e mmvmv mare REFERENCE ANCHOR REFERENCE ANCHOR �RE CONNECTION TYPE SCHEDULE FOR MAX. SCHEDULSPACIING E FOR MAX.1/2 HEDUEFERELE FOR MAX. SPACING EDESPACING 11 CONT. - FOR LARGER SPANS E TWO 2" x 5" AL. ANGLES (SEE SCHEDULE 1 TYPE C) MAX. OCEILIpNSIDE MOUNT SECTION OBUILD-OUT MOUNT SECTION SCALRE: 3" = 1'-0" C SCALE: 3" = T-0" 1 3" 1 EXISTING CONCRETE, MASONRY OR WOOD STRUCTURE. SEE ANCHOR SCHEDULE, TYP. EXISTING WOOD TRUSS OR RAFTER C1 CONNECTION TYPE @ 24" MAX. D.C. t REFERENCE ANCHOR EXISTING WOOD OR 1/4-20 MACHINE BOLT W/ EMB. SCHEDULE FOR MAX. STUCCO FINISH NUT @ 12" O.C. (TYP., TOP ' % SPACING MATERIAL & BOTTOM) _ %� 22 TYP. TOP & BOTTOM 5/8" ROLLER ASSEMBLY w 1/2"- �/2„ TYP. EVERY OTHER PIN v). io 0 1/2" MAX: 0 1/4" MAX. #14 SMS (nl 24" _ O.C. MAX. N 9 1/4" MAX. Z BETWEEN TRUSSES Qw Ww am SEE TABLE 2 a tn- O F-w �Q 00 q 3Q 2z OLL OR DOOR O w p~ I— JL XJQpo j Q_j SEE TABLE 2 Q X= 2-7/8' in Xo E Fw u MAX. x Eu Q win 4" MAX. -;�„ Y_ in _ 20 �, p�j w A H 1/4" MAX. /II `-5/8" MAX. NOTE: BOTTOM MOUNT DETAIL MAY BE USED AT TOP. OBUILD-OUT MOUNT SECTION E SCALE: 3" = 1'-0" C2 CONNECTION TYPE REFERENCE ANCHOR SCHEDULE FOR MAX. SPACING BUT DO NOT EXCEED 8-1/2" SPACING 5/8" MAX. OBUILD-OUT MOUNT SECTION D SCALE: 3" = 1'-0" 4" x 1/8" 6063-T6 ALUM. CONTINUOUS PLATE W/ THREE 1/4"0 WOOD LAG SCREWS WITH 2-3/4" w; MINIMUM THREADED a� PENETR. "T" IN WOOD C)a Q EACH RAFTER OF TRUSS, it 24" O.C. MAX. WHERE Fz-w PLATE EXTENDS a BEYOND LAST TRUSS, EXTEND PLATE TO NEXT TRUSS 1/4" MAX. z Q� aw 11- In-i � 3Q w OF- � JJ Qp u1 QW iu win n 1/4" MAX. -16 pRODUC7; REVISEED cr W F- c� 2 Z orn O z .W 01 or 0)p��0 0= O m On C) U owmr, V Q W W a) Q 1L QU z z a 3Fzx ZOQ Q O Oc c X IL "0 o d a T V J. Knezevich Professional Engineer FL License No.: PE0010983 J � 0 2406 �) o Ln C z' N) o" 0 `a N O �D 0 0 m L c � C4 CONNECTION TYPE _ EMBED. REFERENCE ANCHOR ��di��C°��'e 1 CONNECTION TYPE SCHEDULE FOR MAX. AccV%.:Sacs N'00 C ZZ �'03 Ulu EFERENCE ANCHOR SPACING c3lpiraiiopoale. oil SCHEDULE FOR MAX. die 09/14/2005 SPACING 5/8" EXISTING CONCRETE, MASONRY la-4 �,ml IDav�CluhllAS NOTED drams NICK OR WOOD STRUCTURE. SEE (�, Division --g—n e aa ANCHOR SCHEDULE, TYP WOOD SOFFIT / OBUILD-OUT MOUNT SECTION OFLOOR MOUNT SECTION 1' SCALE: 3" = -0" SCALE: 3" = 1'-0" drawing no. 06-303 sheet 3 of C 0 in rn LO 0 u7 0 a 0 N 0 0 cq c 0 U 2 EXISTING STRUCTURE TWO 3/8"0 POWERS CALK -IN P 3-3/4" O.C. W/ 1-1/4 MIN. EMBED. IN 3 KSI CONC. WITH 4-1/2" MIN. EDGE DIST. OR FOUR 1/4"0 ELCO CRETE-FLE 3" O.C. W/ 1-3/4" MBEDMENT & 2-1/2" EDGE DIST. IN EACH ANGLE /B" MAX. 2" x 3" x 1/4" /----6063-T6 ALUM. ANGLE _ —, /-DETAILS V1 &© 1-1/4" THREE-1/4"O THRU BOLTS 1" MIN. ALUM. BEAM (S Tw SCHEDULE BEL BEAM DESCRIP - MAX. HORIZON Tf 1/4-20 S.S. M & NUT @ 12" BOLT OR ACC 1 SHOWN IN DE ALT. LEG DIRECTION SEE TABLE 2 ALUM. BEAM & SHUTTER SCHEDULE SHUTTER BEAM DESCRIPTION SPAN SPAN 2" x 5" 5'-0" 91-51• 8'-0" 8.-11. Tw = .125" Tf = .125" 10'-0" 7'-6" x 2" 8" 5'-0" 14'-0" B'-0" 11'-6" Tw = .072" Tf = .224" 10'-0" 10'-4" 2" x 9" 5'-0" 15'-5" 8'-0" 12'-5" Tw = .072" Tf = .224" 10'-0" 11'-2" OSS R DOOR TWO 3/8"0 POWERS CALK -IN P 3-3/4" O.C. W/ 1-1/4 MIN. EMBED. IN 3 KSI CONC. WITH 4-1/2" MIN. EDGE DIST. OR FOUR 1/4"0 ELCO CRETE-FLE 3" O.C. W/ 1-3/4" MBEDMENT & 2-1/2" EDGE DIST. IN EACH ANGLE (MAX. DESIGN LOAD *72 PSF) @)TOP SUPPORT BEAM DETAIL 1' H SCALE: 3" = -0" Z to Q o_ w w H F- 2 N X Q F EE BEAM OW FOR TION & TAL SPANS) o ACHINE SCREW O.C. USE THRU ESS OLE AS 1.50' TAIL J 4" MAX. 3.001• DRILL 7/16"0 HOLE DRILL 5/16"0 HOLE 1� 13" 3.75" 0 0 0 O N 1.12" 1.88" 6.60' °aLd J Of �� w0 �_�= J �a ANGLE DETAIL USING CALK -IN ANCHOR F_ to SCALE: 3"= 1'- 0" ::)a:=XQ JF-HQZ QI--Zz-a DRILL 5/16"0 W=o0N HOLE 1.00" 3.00" 3,00" 3,00" �a LL - o rvi o _ c N 1.50" 2.501, 3.00" 3.00" 3.00' 11.00" NOTE: 1. USE BEAM SCHEULE FOR DETAILS H AND J . 2. SHUTTER SPAN TO BE LIMITED TO THOSE SHOWN IN TABLE, SHEET 5. 3. BEAM SPAN SHALL BE CONSIDERED AS THE DISTANCE FROM CLOF SUPPORT TO fL OF SUPPORT. V2 ANGLE DETAIL USING CRETE-FLEX ANCHOR SCALE: 3"= T- 0" OR DOOR W==z)3 8 uJ mNV)No ��NJ C Q _Jw=Xz 2 I-.Q 6 p v E OR1#12 JEK SCREW in X W=oo:N @6"0. Q tn= a 1n 4 E LL MBL 04 3/16"0 POP RIVET LASOR OR #12 TEK SCREW @ 6" O.C. AL. BEAM (SEE BEAM SCHEDULE ABOVE FOR DETAILS Tf BEAM DESCRIPTION 8. _ &© I MAX. HORIZONTAL SPANS) 1/4-20 S.S. MACHINE SCREW &1. 1. SEE TABLE 2 1/2" SEE TABLE 2 1/2" C i MACHINE SCREW & NUT EMBED. 1/4-20 S.S. r 12" O.C. PROVIDE 1"0 ACCESS HOLE (al BACK SIDE FOR FASTENING PLYWOOD AND TWO 1/4" 0 S.S. LAG SCREW Cal STUCCO FINISH 24" O.C. MAX. W/ 1-3/4" PEN R. 5/8" MAX. IN CENTER OF STUDS �_`!" x 3" x 1/8" OR 1" x 4" x 1/8" 6063-T6 ALUM. TUBE q (MAX. DESIGN LOAD * 72 PSF) @) WALL MOUNT SECTION - USING ALUM. TUBE 2.50" I SCALE: 3" = T-0" EXISTING CONCRETE, MASONRY OR WOOD STRUCTURE. SEE ANCHOR SCHEDULE. TYP. Ea. Q. yM 5/B" MAX. m s C4 CONNECTION TYPE REFERENCE ANCHOR �4�Sr SPAC NG E FOR MAX MAX. Z 2 Q� u�Q OR DOOR g _! Zow i QJ� X! �Qo yN E ;C ;P F,• X. T�� NUT 12 O.C. PROVIDE 1 w N ?": FOR WOOD PLATE USE 1/4"0 `s 1" MIN. ACC SS HOLE IN BOTTOM OF <�. EMBED. S.S. LAG SCREW W/ 1-3/4". ACCES BEAM OR USE THR BOLT AS PENETRATION INTO WOOD HOLE SHOWN IN DETAIL(H) PLATE @ 12" O.C. 2" x 3" x 1/4" TWO 1/4"0 S.S. LAG SCREW 6063-T6 ALUM. ANGLE PLYWOOD AND 24" O.C. MAX. W/ 1-3/4" xx TTINN 5� I "b THREE-1/4"O THRU BOLTS STUCCO FINISH PENETRATION IN CENTER OF STRSUl1TURE MAX_—" 5/B" MAX. STUDS ALT. LEG DIRECTION 2" x 6" P.T. WOOD PLATE (MAX. DESIGN LOAD* 72 PSF) (MAX. DESIGN LOAD * 72 PSF) @)BOTTOM SUPPORT BEAM DETAIL OWALL MOUNT SECTION - USING 2" x 6° P.T. WOOD PLATE J SCALE: 3" = 1'-0" K SCALE: 3" = T-0" SEE TABLE 3/16"� POP RIVET OR #12 TEK SCREW @ 6" O.C. (TYP.) ASSEMBLY �CTION TYPE CE ANCHOR E FOR MAX. ENCE ANCHOR jxuut ui� IT VG E FOR MAX. OCEILING/INSIDE MOUNT SECTION L SCALE: 3" = 1'=0" '4" A X. PRG-pillule REVISF;!.5 z^ mvp5y' e c hN, .fix fjc 906—o 2 •o3 336disio� O oa c Z O — a-+ �o E u z CJ v� R w 9m 7 Cz �N a FEl- _ C) :/1Nt W #•1 a+ K i F O �o« �o } i-1 to y N 0 O _811-4 N3 z �[ c a+ w ¢:n r U rnF U F S V.J. Knezevich Professional Engineer FL License Nu.: PE 0010983 Jk22006 o � o Ln c= O . < N ". 09/14/2005 1 AS NOTED I I MCR drawing no. 06-303 sheet 4 of N ' O 0 E rn d- LO 0 0 0 0 0 C 0 c 0 U E 0 0 O E c c n`. ASTENER 9 24" O.C. JSE ANY ANCHOR IN ,NCHOR SCHEDULE) #10 x 1/2" GALVANIZED SMS OR 3/16"0 ALUM. POP RIVET @ 18" O.C. 1" x 1" x .055" • 1" x 2" x .055"- 2" x 3" x .055" ; 2" x 4" x .0�! OR 2" x 5" x .125" AL, ANGLE t77A;NCH;ORSCHEDULE) 24" O.C. NCHOR IN #10 x 1/2" GALVANIZED SMS OR 3/16"0 ALUM. POP RIVET @ 18" O.C. 1" x 1" x .055" ; 1" x 2" x .055"; 2" x 3" x .055" • 2" x 4" x .05E OR 2" x 5" x .12�" AL. ANGLE OALT. CLOSURE DETAIL SCALE: 3" = 1'-0" 1" x 2" x 1/8" ALUM. ANGLE o 3 #10 TEK SCREWS OR 3-3/16"0 ALUM. ° POP RIVETS (TYP.) A B MAXIMUM ALLOWABLE SPAN SCHEDULE L E NEG. DESIGN LOAD (PSF) TYPE A ALL MOUNTING CONDITIONS EXCEPT ©�V (FT - IN) TYPE B DETAIL (2) OR DETAIL © W/ SINGLE ANGLE REQUIRED MAX/B.0, (FT - IN) TYPE C DETAIL C DOUBLE ANGLE REQUIRED 3-3/4" MAX. B.O. (FT - IN) TYPE D DETAIL t�E 9-3/16" MAX. B.O. (FT - IN) 30.0 13- 1 12-4 13-1 12-7 38.0 13 - 1 11 - 0 13 - 1 11 - 2 40.0 12- 11 10-8 12-5 10- 11 48.0 12-4 9-9 10-4 10-0 52.0 12- 1 9-4 9-7 9-7 56.0 11 - 11 9-0 9-0 9-3 61.5 11 - 7 8- 7 8- 7 8- 10 63.3 11 -6 8-6 8-6 8-8 66.8 10- 11 8-3 8-3 8-5 67.5 10 -9 8-3 8-3 8-5 71.2 10 - 3 8- 0 8- 0 8- 2 75.0 9-8 7-8 7-8 8-0 81.4 8- 11 7- 0 7- 0 7- 4 86.8 8-5 6-7 6-7 6- 10 91.4 8- 0 6- 3 6- 3 6- 6 100.0 7-3 5-9 5-9 6-0 110.0 6- 7 5- 2 5- 2 5- 5 120.0 6- 1 4-9 4-9 5-0 130.0 5-7 4-5 4-5 4-7 140.0 5-2 4- 1 4-1 4-3 150.0 4- 10 3-10 3-10 4-0 160.0 4-6 3-7 3-7 3-9 170.0 4-3 3-4 3-4 3-6 2" x 2" x 1/8" a&rR(CP9. #10 TEK SCREW OR 3/16"0 ALUM. TUBE ALUM. POP RIVET @ 24" O.C. 6063-T6 ALLO(TYP.) TWO 1/4"0 FASTENERS EACH ANGLE (SEE ANCHOR SCHEDULE FOR ANY ACCEPTABLE ANCHOR) NOTE: EITHER CONDITION MAY BE TYPICAL FOR EITHER SIDE OCORNP ER CLOSURE DETAIL SCALE: 3" = T-0 x 2" x .125" UM. ANGLE CONT. 1/4-20 TRUSS HEAD BOLTS 9, NUTS W/ LOCK WASHERS @ EXISTING STRUCTURE g HALF OFOB USE MALE OR FEMALE AS REQUIRED OALT. CORNER CLOSURE DETAIL Q SCALE: 3" = T-0" NOTES: 1. REFERENCE APPROPRIATE COLUMN IN TABLE 1 BASED ON MOUNTING CONDITION IN FIELD. 2. FOR DESIGN LOADS BETWEEN TABULATED VALUES, USE NEXT HIGHER LOAD OR LINEAR INTERPOLATION MAY BE USED TO DETERMINE ALLOWABLE SPANS. 3, ENTER TABLE 1 WITH NEGATIVE DESIGN LOAD TO DETERMINE MAX. SHUTTER SPAN. 4. ENTER TABLE 2 WITH POSITIVE DESIGN LOAD TO DETERMINE MIN. SHUTTER SEPARATION FROM GLASS. MIN. SHUTTER SEPARATION FROM GLASS (SEE SCHEDULE SHEET 5) 0.062" THICK RECESSED SILL 3105-H32 OR 6063-T6 ALUM. ALLOY (1/8" BELOW CONCRETE) z a `" a Nw a � m w JH � JW D Q? Xw a X �� a w v) T A MINIMUM SHUTTER SEPARATION FROM GLASS (IN) B L E Z POSITIVE DESIGN LOAD (W) (PSF) ACTUAL SPAN (FT - IN) MINIMUM SEPARATION FROM GLASS FOR INSTALLATIONS LESS THAN OR EQUAL TO 30' ABOVE GRADE (INCHES) MINIMUM SEPARATION FROM GLASS FOR INSTALLATIONS GREATER THAN 30' ABOVE GRADE (INCHES) 30.0 5 - 0 2-7/8 1-1/2 7 - 0 2-7/8 1-5/8 8 - 0 2-7/8 1-5/8 11 - 0 3 2-1/8 13 - 1 3-3/4 2-3/4 CO 5 - 0 2-7/8 1-1/2 7 - 0 2-7/8 1-5/8 0 2-7/8 1-5/8 11- 0 3 2-1/4 12 - 11 3-3/4 3 50.0 5 - 0 2-7/8 1-1/2 7 - 0 2-7/8 1-5/8 8 - 0 2-7/8 1-3/4 11 - 0 3 2-1/2 12 - 2 3-3/4 3 60.0 5 - 0 2-7/8 1-1/2 7 - 0 2-7/8 1-5/8 8 - 0 2-7/8 1-3/4 11 - 0 3 1-3/4 11 - 8 3-3/4 3 70.0 5 - 0 2-7/8 1-1/2 7 - 0 2-7/8 1-5/8 8 - 0 '2-7/8 1-7/8 9 - 6 3 2-1/4 10 - 4 3 2-5/8 80.0 5 - 0 2-7/8 1-1/2 7- 0 2-7/8 1-3/4 1 8 - 0 2-7/8. 1-7/8 ; 11 - 0 3-1/8: 3-1/8 12-1 4 4 90.0 5 - 0 2-7/8 1-1/2 7 - 0 2-7/8 1-3/4 8 - 0 2-7/8 2 11- 0 3-3/8 3-3/8 11 - 6 3-7/8 4 100.0 5 - 0 2-7/8 1-1/2 7 - 0 2-7/8 1-3/4 8 - 0 2-7/8 2 9 - 0 3 12-3/4 10 - 3 3 13 W to 1/4" MAX. d , . 4" V° : NG STRUCTURE MICNS 3I 000 PSI CONCRETE G CONCRETE FASTENER @ 8" O.C. 41 a ANY SCHEDULED FASTENER IS ACCEPTABLE OALTERNATE FLOOR MOUNT DETAIL SCALE: 3" = V-0" P a ODUCT P.EVIISED i�S:P:�iL'R'r8�2 E.3. 4-10@is Da"a O 13y MU ai DadelOfeftzf CveeW Divi,i011 U m coZ ca Z 0 ® Z � <r- v go w 0X: o 0o°r° m U U 13 -OD U Q mwNm ¢ 1L U -r cv QU z �Jv z Q 3�zii ui -0a 7 a0 M IL UHL - o 0 a a Professional Engineer FL License No.: PE 0010983 JA 2 2J06 T d -v d\ O �z Ln °00 O a N r mo N w L � a Q Y 4 j 9 P c� date 09/14/2005 sale drawn by AS NOTED j I MCR esign V K VJK drawing no. 06-303 sheet 5 Of 7 C a O E C to 0 LO 0 co 0 0 04 0 c 0 U a ANCHOR SCHEDULE FASTENER MA)UMUM SPACING (INCHES) REQUIRED • • DESIGN LOADS ••MIN. 20 EDGE DISTANCE MIN. 3n EDGE DISTANCE SPANS UP TO SPANS UP TO SPANS UP TO SPANS UP TO SPANS UP TO SPANS UP T SPANS UP TO • 1 1 , • • .NOTE 1) (SEE NOTE 1) (SEE NOTE 1)__ (SEE NOTE 1) _(SEENOTEl) (SEE NOTE 1) • • • • • • • • • • • • • • • • • • • • , • • • 1-1/4" MIN, EMBEDMENT 1 1 ©ii©i©�'I"'E""I9©©©'©'�I©'©"©'©"©' MUM UM jr ©" A U"" ©�'©' ©"©' ©'i ©"©' ��„�� �mmm00000©000©©iimmmo©mmmoomoo©©a%o �mmmo©oo©©loll©©immmo©o©o©©o©©©ioioi „ POWERS EMBEDMENT ' SCREWSTEEL MACHINE Mail INUEVO I i I 1/4"0 POWERS NAIL -IN Apr MIN. EMBEDMENT mmm©©0%%©% ©©©%0%/%©%®m®EE0%©%%%©©%'//.0OAFWA9&1 EFEMALE MBEDMENT :► • pUpp 041 Fir 00 SCREW_WITH NUT AJEF 'ESP ur ]I♦11111111tN1{11111111\l\ll. � mmmm©m�©m' m"©' ©"'©' ®®®m©m©�©©m©©m' m"©' HEX HEAD TAPCON W1 1-1/4" EMBED EMBEDMENT 1 • m©©m'©"©Map '©"i©'PUP ©F'©MIN %mm©©©m%%m%m.'//.%©%m"//. 'no POV FEW par PUP ANCHOR NOTES: 1. SPANS AND LOADS SHOWN HERE ARE FOR DETERMINING ANCHOR SPACING ONLY. ALLOWABLE STORM SHUTTER SPANS FOR SPECIFIC LOADS MUST BE LIMITED TO THOSE SHOWN IN TABLE 1, PAGE S. 2. ENTER ANCHOR SCHEDULE BASED ON THE EXISTING STRUCTURE MATERIAL, ANCHOR TYPE AND EDGE DISTANCE. SELECT DESIGN LOAD GREATER THAN OR EQUAL TO NEGATIVE DESIGN LOAD ON SHUTTER AND SELECT SPAN GREATER THAN OR EQUAL TO SHUTTER SPAN. 3 REFERIENCE ANCHORRSCHEDULE FORCPROPkR ANCHOR TYPE BASWOOD D ON TYPE OF EXISTING STRUCTURE AND APPROPRIATE CONNECTION TYPE. SEE MOUNTING SECTION DETAILS FOR IDENTIFICATION OF CONNECTION TYPE. 4. ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS. 5. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDES WALL FINISH OR STUCCO. 6. WHERE EXISTING STRUCTURE IS WOOD FRAMING WOOD FRAMING CONDITIONS VARY. FIELD VERIFY THAT FASTENERS ARE INT6 ADEQUATE WOOD FRAMING MEMBERS, NOT PLYWOOD. FASTENING TO PLYWOOD IS ACCEPTABLE ONLY FOR SIDE CLOSURE PIECES. 7. WHERE LAG SCREWS FASTEN TO NARROW FACE OF STUD FRAMINGt FASTENER SHALL BE LOCATED IN CENTER OF NOMINAL 2" x 4" (MIN.) WOOD STUD. 3/4" EDGE DISTANCE IS ACCEPTABLE FOR WOOD FRAMING. WOOD STUD SHALL BE "SOUTHERN PINE" G=0.55 OR GREATER DENSITY. LAG SCREWS SHALL HAVE PHILLIPS PAN HEAD OR HEX HEAD. 8. MACHINE SCREWS SHALL HAVE MINIMUM OF 1/2" ENGAGEMENT OF THREADS IN BASE ANCHOR AND MAY HAVE EITHER A PAN HEAD, TRUSS HEAD, OR WAFER HEAD (SIDEWALK BOLT), U.O.N. 9. ® DESIGNATES ANCHOR CONDITIONS WHICH ARE NOT ACCEPTABLE USES 10. * DESIGNATES ANCHORS WHICH ARE REMOVABLE BY REMOVING MACHINE SCREW, NUT OR WASHERED WINGNUT. 11. FOR BUILD -OUT MOUNT SECTION OD ANCHOR SPACING SHALL NOT EXCEED B-1/2" O.C. 12. FOR BUILD -OUT MOUNT SECTION E@ANCHOR SPACING SHALL NOT EXCEED 6" O.C. FRODUCT REVISES D as cam. p ykv W aal• 9&0 F'Sa9rrma Amat-mice b6 oZZ1.o3 Exgs3•.' o ;���0�1 By Mlwnl ip,ad nor uct Cszubvi Dal'13 on O — — { Mn 'A r I� J3F 2 0 LL¢ cc -1-� v E va3 R =w M 3 k �+ cd �Nu Fi C y O gvr x 0 W Mu LL F- _ 0 M s 0 0 uj O �N1� o to u W ED U m co z v >mm o z doom It 0' Q m0��r 0 r w U no ��N� IL Q UrR vn z z g Zzx ��aLL a ° � m� oIY -0 a i, V J. Knezevich Professional Engineer FL License No.: PE 0010983 e 09/14/20051 1S NOTED MCR eslgn VIK a VIK drawing no. 06-303 sheet 7 of 7