Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSOffice Use Onl3 Master # � R10P' Date: Permit #..�� St. Lucie County Building & Zoning 2300 Virginia Avenue Ft. Pierce, FL 34982-5652 Tel. 561-462-1553 ��,q� APPLICATION FOR ROOF PERMIT 4�'c% C SEE PAGE 2 FOR INSTRUCTIONS ou 1. 'Location/Site Address: Y5 I a F I 0 re s Fi , Pi er c'_ ioY 1 L 3 <Jcf,54- 2. Parcel ID Number: 1306-111-0001=000/0 SPANISH LAKES FAIRWAYS vI . d 1 tr- _ .r ex�°s�'i�n to© �nslll`.') I�t er 3ott, l/t5i1� 2rhoye 5 i =y 3. Description of Project or Work Activity: `Isle-ywl- held a�sphGl ins' -q 11 'ntw 3 •-` iq SIJ n) 4. Total Roof Area (square feet): 0 OU Roof Pitch: 5 / �. 5. Type of Roof: Fiberglass Shingle [ g] Barrel/Tile Ceramic [ ] Food Shake Shingle [ ] Tar & Gravel [ ] Other (specify) 6. Owner Information Name: WYNNE BUILDING CORPORATION Address: 8000 S US 1 SUITE 402 City: PORT ST. LUCIE State: FL Zip: 34952 Phone: 772-878-5113 jj Qa 8. Value of Construction: $ 2CIO, 7. Contractor Information FL Reg/Cert #: CCC1326344 County Cert#: 22608 Business Name: BIG LAKE ROOFING On'ERPRISES Fees Due: Receipt# OWNER'S AFFIDAVIT: I certify that all of the information contained in this -application is co ect and that all wo c will be done in compliance with all applicable laws regulating construction and zoning. MARK RONKKO \\\MH\\\Y PRINT QUALIFIERS/OWNERS NAME SIGNATURE OF QUALIFIER/OWNER STATE OF FLORIDA, COUNTY OF l;.f I C 2-eC I/141De `®a 4.1 . ACKNOWLEDGED BEFORE ME THIS DAY•OF Y 20M., BY : """'" 0. MARK RONKKO WHO IS PERSONALLY KNOWN O ME OR WHO HASH me PRODUCED AS IDENTIFICATION. ' ° m go .CL m y� , {�x SIGNATURE OF NOTARY TYPE OR PRINT NAME OF NOTARY (seal) TITLE: NOTARY PUBLIC COMMISSION NUMBER' •7 N I'l A : NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. EXEMPT: A/C - HEAT REPLACEMENT WITH CONTRACT UNDER $5,000. INSTRUCTIONS Please complete all information in the space provided. All information must be printed (use black or blue ink St. Lucie County Roof Permit Application EDWIN M. FRY, Jr., Cr,c.nv OF THE CIRCUIT COURT - SAINT LUCIE COUNTY FILE # 3196008 OR Bt 2963 PAGE 1302, Recorded 04/18/2001;•' -' 02:03 PM AFTER RECORDINC-REn iRN TO• PERMIT NUM RER: NOTICE OF COMMENCEMENT The undersigned hereby given notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida statutes the following information is provided in the Notice of commencement. L DESCRIPTION OF PROPERTY (Legal description and street address) TAX FOLIO NUMBER: 1/384- 111- = ( '000•-40 2. GENERAL DESCRIPTION OF IMPROVEMENT: - KO 6 F 3. OWNER INFORMATION: a. Name_ W 3 V111 E I) fNa-p m a�� ipn / GI Ji• i ns b. Address l'aW`t 5JN}�t1Le1 Mi[emi IFT ��'�-- c. interest in property 1 (�C'/e d. Name and address of fee simple titleholder (if other than owner) 4. CONTRACTOR'S NAME ADDRE,.S AND PHONE NUMBER: B i Q "k a Qen AAq F n Fef Pf i !S-e S r�1v94 t.1W 1loTM��1yCl 0Keechnbeje.Ft 5. SURETY'S NAME, ADDRESS AND PHONE NUMBER AND BOND AMOUNT: 6. LENDER'S NAME, ADDRESS AND PHONE NUMBER: 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13 (])(a) 7., Florida Statutes: NAME, ADDRESS AND PHONE NUMBER: 8. In addition to himself or herself, Owner designates the following to receive a copy of the Lienor's Notice as provided in Section 713.13 (1)(b), Florida Statutes: NAME, ADDRESS AND PHONE NUMBER: 9. Expiration date of notice of commencement (the expiration date is I year from the date of recording unless a different date is specified) _, 20_. �lln ��_nu<ir15 Dane[ Print Name and Provide Signatory's Title/Office Owner's Authorized Officer/Director/Partner/Manager Slate of Florida County of s GI e The foregog instrument�wOas acknowledged before me this /O ilk day of 6 f .' 20 a 8 By Qt1Ltt US,1nA as Qciary-e (Name of person)'A (Type of authority... e.g. Owner, officer, trustee, attorney in fact) Far""" �����,p1111111111!/yf/ (Name of pony on behalf of wham instrument was executed) Personally Known-�Q11�iR1lyAF$gJl�F�dpJpwing type of ID: �� S � � l�Q�sl 1 7��'°C9 •� 4f 4de- IZ6hILiLo �* i , in (Printed Name of Notary Public) (Signature of Notary Public) -f5 tDD 664901 ' c Under penalties of perjury, I declare that I have read the foregoing and that the factf my knowledge and belief (section 92.$25, Florida Statutes). %/�;�!'/8,,,,•„T"'T . ,u Signature(s) of Owner(s) or Owner(s)' Authorized Officer/Director/Partner/Mn aager who signed above: \y � By Ro'.IIW,l1Y'_Ia71R�mrdinrt STATE OF FLORIDA ST, LUCIE 00UMTY Cf��lhl THIS TOCERTIfYTHAT THIS ISA TS-UEAND CORRECT COPY 0-THE •'�� G� ��Gi EpWIN FI Y, JR., CLERK �` rn A tyCQl@f5, !�c/nOy Et �oQ�o �: - / ( 6 0 �7 F0011oil � �e Property Appraiser - St.Lucie County, FL Page 1 of 1 PROPERTY RECORD CARD Wynne Building Corp Record: 1 of 3 <<Prev Next» Spec.Assmnt Taxes Exemptions Permits Home Print Property Identification Site Address: 6487 SPANISH LAKES BV ParcellD: 1306-111-0001-000-0 Sec/Town/Range: 06 :34S :39E Account #: 4031 Map ID: 13/06N Land Use: PRKG/MOBILE Zoning: PUD City/Cnty: ST. LUCIE COUNTY Ownership and Mailing Legal Description Owner: Wynne Building Corp 06/07 34 39 ALL THAT PART LYG NELY.OF 1-95-LESS SPANISH Address: 12804 SW 122nd Ave LAKES FAIRWAYS (PB 35-5) AND LESS THAT PART Miami FL 33186-6203 More... Sales Information Assessment Final Total Land and Building Date Price Code Deed Book/Page 2007 FV: 25354600 Land Value: 21860000 Acres: 332.14 " 5/1/1986 1315000 02 CV 0502 / 0947 Assessed: 25354600 Building Value: 3494600 1/1/1984 674200 02 CV 0422 / 2136 Ag.Credit: 0 Finished Area: 18467 SgFt Exempt: 0 Taxable: 25354600 Taxes: 478867.25 oo.pt Re0.6t i BUILDING INFORMATION .N0 Image Avail -able Exterior Features View: - RoofCover: - RoofStruct: - ExtType: MHPK - MH Parks YearBit: 999 Frame: - Grade: C - C EffYrBlt: T990 PrimeWall: - StoryHght: 0010 - 1 Story No.Units: SecWall: - Interior Features BedRooms: 1093 Electric: PrmintWall: FullBath: 0 HeatType: - AvgHt/FI: 1/213ath: 0 HeatFuel: - Prm.Flors: - %A/C: 0 %Heated: 0 %Sprinkled: 0 Special Features and Yard Items Land Information Type Y/S Qty. Units Qual. Cond. YrBlt. No. Land Use Type Measure Depth SWAV - RES POOL AVG Y 1 2720 AV AV 1990 1 2800-PRKG/MOBILE 191 -Site 1093 PA01 - POOL DK-AVG Y 1 6324 AV AV 1990 ASP1 - ASP1 HIGH Y - 1 544000 AV AV 1990 CNC2 - CONCRETE LOW Y 1 13152 AV AV 1990 CURB - CEMENT CURB Y 1 700 AV AV 1990 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED h4://www.paslc.org/pre.asp?prclid=130611100010000 4/18/2008 Friday, Apr 18, 2008 02:52 PM Code Compliance Division 2300 Virginia Avenue Ft Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1148 hftp://stiucleco.gov/ce Issued: 04/18/2008 Job Location: 14042 ISLA FLORES Permit Type: Roof Job Description -IJILDING PERMIT Page .1 Conf #; 728 Permit #: SLC- 0804-0225 City: FORT PIERCE REMOVE EXISTING ROOF AND INSTAL 1 LAYER OF 30# FELT AND INSTALL WETHEET W/HOT ASPHALT AND FINISH WITH 3-TAB FIBERGLASS SHINGLES 1700 SQ FT 2.5/12P S/D Spanish Lakes Fairways NE Phas Lot: Block: Parcel: 1306-111-0001-000/0 Contractor MARK RONKKO BIG LAKE ROOFING ENTERPRISES II` (863) 763-7663 2699 NW 16TH BLVD OKEECHOBEE, FL 34972 Property Owner WYNNE BUILDING CORP (772) 878-5513 12804 SW 122ND AVE Setbacks Left: Number of Units: 1.00 Minimum Floor Elevation: MIAMI, FL 33186-6203 Right: Front: Rear: Zoning: PUD Floors: 1 Buildings: 1 Square Footage: 0.00 Flood Map: Flood Zone: Elev: Permit holder acknowledges through acceptance of this permit that separate permits must be obtained as required by the Florida Building Code including those for all electric, plumbing, mechanical, roofing, and structural work. Further, he/she acknowledges responsibility to comply with all requirements of the 2004 Florida Building Code. NOTICE: In addition to the requirements in this permit, there may be additional restrictions applicable to this property that may be found in the records of this County, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. s:553.79(10), F.S. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR BUILDING IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. s.713.135, F.S. Christopher Lestrange Building Official Date For Automated Inspections, Call (772) 462-1261 For Questions, Call (772) 462-2172 St. Lucie County Land Development Code Section 11.05.01 (A) (2) states; Building Permits shall expire and become null and void if work authorized by such Building Permit is not commenced, having called for and received a satisfactory inspection, within six (6) months from the date of issuance of the permit, or if the work is not completed within 18 months (permit by contractor) or 24 months (permit by owner) from the date of issuance of the Building Permit. St-.GJ� Building Code Compliance Division Receipt 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 hftp://stiucleco.gov/ce Date: 18 April 2008 Job Address: 14042 ISLA FLORES Received By: dimonb Paid With: CK Paid By: BIG LAKE ROOFING ENTERPRISES, INC Sign: Receipt #: 0000062250 'ermit Number: SLC- 0804-0225 Amount: $230.00 �redit Card Number: Check Number: 2179 a M I A M I•DADE BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION r NOTICE OF ACCEPTANCE Owens Corning One Owens CorningParkway Toledo, OH 43659 SCOPE: Fay- �o�v�� F0,; �O MIAMI-DADE COUNTY, FLORIDA METRO-DADE FLAGLER BUILDING T FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130-1563 (30 375-2901 FAX (305) 375-2908 This NOA is being issued under the applicable ruled regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Supreme AR 3 Tab Shingles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA-. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews NOA #06-1113.06 and consists of pages 1 through 4. The submitted documentation was reviewed by Alex Tigera. NOA No.: 07-1116.12 MIA Expiration Date: 03/20/13 VAIF 11LE COP'" Approval Date: 02/14/08 :rs+ Page 1 of 4 P3 wi_` 0 y0cf,",a J2s- ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -Category: 07310 Asphalt Shingles Materials 3-Tab Deck Type: Wood I. SCOPE This renews Owens Coming Supreme AR as manufactured by Owens Corning described in Section 2 of this Notice of Acceptance. 2. PRODUCT DESCRIPTION Product Dimensions Test Specifications Supreme AR 12" x 36" 3. EVIDENCE SUBMITTED: Test Agency Underwriters Laboratories, Inc. Underwriters Laboratories, Inc. Underwriters Laboratories, Inc. PRI Asphalt Technologies, Inc. TAS 110 Test Identifier 02NK45241 05CA53426 02NK45241 03NK04954 04CA52475 06CA03524 04NK40618 R2453 OCF-067-02-01 OCF-076-02-01 OCF-094-02-01 OCF-095-02-01 Product Description A heavy weight, fiberglass reinforced asphalt shingle. Test Name/Revort Date ASTM D 3462 12/05/97 12/02/05 TAS 107 11/14/02 03/20/03 03/23/05 03/30/06 11/12/04 Reference 01/09/03 TAS 100 11/12/02 02/24/04 08/29/06 09/22/06 4. LIMITATIONS 4.1 Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 4.2 Shall not be installed on roof mean heights in excess of 33 ft. S. INSTALLATION 5.1 Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 5.2 Flashing shall be in accordance with Roofing Application Standard RAS 115 5.3 The manufacturer shall provide clearly written application instructions. 5.4 Exposure and course layout shall be in compliance with Detail 'A', attached. 5.5 Nailing shall be in compliance with Detail 'B', attached. NOA No.: 07-1116.12 MIAMEDAOE C• �OUNTY Expiration Date: 03/20/13 nu l - Approval Date: 02/14/08 Page 2 of 4 6. LABELING 6.1 Shingles shall be labeled with the Miami -Dade Logo or the wording "Miami -Dade County Product Control Approved". 7. BUILDING PERMIT REQUIREMENTS 7.1 Application for building permit shall be accompanied by copies of the following: 7.1.1 This Notice of Acceptance. 7.1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. 8. MANUFACTURING PLANTS 8.1 Atlanta, GA 8.2 Jacksonville, FL 8.3 Irving, TX 8.4 Memphis, TN. 8.5 Jessup, MN. 8.6 Medina, OH. L APPROVED •x� e NOA No.: 07-1116.12 Expiration Date: 03/20/13 Approval Date: 02/14/08 Page 3 of 4 DETAIL A DETAIL B' 3;1 • 55" NAILS 8 $ I EXPOSURE 5" 1 q" Fz3 ADHESIVE STRIPE 2"----J � 10" END OF THIS ACCEPTANCE NOA No.: 07-1116.12 Expiration Date: 03/20/13 Approval Date: 02/14/08 Page 4 of 4 12" 1" The NRCA Roofing and Waterproofing, Manual —Fifth Edition FASTEN UNDERLAYMENT AS NECESSARY TO HOLD IN PLACE WOOD —DECK Figure 1: Single layer underlayment 36" 2" (910 mm) (50 mm) ' METAL DRIP EDGE APPLIED OVER UNDERLAYMENT METAL DRIP EDGE AT DOWNSLOPE EDGE APPLIED DIRECTLY ON DECK NOTE - DIMENSIONS ARE APPROXIMATE > ..,1� • •D DECK 36" (910 mm) _ / � n•a 4i .taxis � � ._ ^..v� i .. i•.��_ METAL DRIP EDGE APPLIED OVER UNDERLAYMENT METAL DRIP EDGE — ;x= < `� AT DOWNSLOPE EDGE APPLIED DIRECTLY ON DECK A PLY OF SELF -ADHERING UNDERLAYMENT MATERIAL INSTALLED UP TO A POINT 24" (610 mm) OR 36"(910 mm), AS REQUIRED, INSIDE THE EXTERIOR WALL LINE OF THE BUILDING TO PROVIDE AN ICE DAM NOTE - ALL DIMENSIONS ARE APPROXIMATE PROTECTION MEMBRANE 1� :figure 2: Single layer )f underlayment with ce dam protection nembrane Asphalt Shingle Roof Systems 337 i The NRCA Roofing and Waterproofing Manual —Fifth Edition Nails should be driven straight, flush and snug to the surface of asphalt shingles. The nailing of hips, ridges and some roof accessories may require the use of longer nails because fasteners must penetrate through more layers of roofing and/or material. For full -width shingles, a minimum of four nails should be used per shingle. See Figure 7. Figure 7: Approximate fastener locations for four -nail pattern Six nails per full -width strip shingle may be --required by building codes in some high -wind areas. See Figure 8. Figure 8: Approximate fastener locations for a six -nail pattern For roof slopes 18:12 (56 degrees) and greater, NRCA recommends that asphalt shingles be fastened with six nails and manually sealed with asphalt flashing cement. The latter process is commonly known as "hand tabbing." Some manufacturers require six nails per shingle and hand tabbing on slopes as low as 12:12 (45 degrees) depending on the shingle product. Consult manufacturers for specific product requirements. For individual shingles, a minimum of two nails should be used per shingle. The locations for asphalt shingle fasteners as shown in Figures 7 and 8 and manufacturers' printed installation in- structions should be recognized as the approximate locations where attachment is intended. Actual consistent fas- tener placement in the exact locations depicted is not possible in the application of asphalt shingles under normal rooftop conditions. The application of asphalt shingles in a rooftop environment is not an exact process and minor deviations from the intended fastener locations should be anticipated and tolerated. Asphalt Shingle Roof Systems 341 The NRCA Roofing and Waterproofing Manual —Fifth Edition 5 INCH PATTERN RAKE 5 INCHES (127 mm) 5 INCHES (127 mm) 5 INCHES (127 mm) Yl CUTOUTS ALIGN �. EVERY SEVENTH nw COURSE FULL -WIDTH SHINGLE EAVE 5 % INCH PATTERN RAKE 5 %INCHES (143 mm) 5 % INCHES (143 mm) 5'/a INCHES (143 mm) i 3 CUTOUTS ALIGN u EVERY SEVENTH ,e COURSE n r FULL -WIDTH SHINGLE i....__. , EAVE STANDARD SIZE SHINGLES METRIC SIZE SHINGLES NOTE: UNDERLAYMENT NOT SHOWN FOR CLARITY Figure 10. Aesthetics of a 5-inch pattern • Cutouts that break joints on halves, or the 6-inch method — This procedure will establish a sidelap gauge pattern for a roof system whereby the cutouts break joints on halves with the course below the cutouts line up in every other course. For standard -size shingles, the offset pattern is achieved by offsetting consecutive shingle courses by 6 inches (150 mm). For metric- sized shingles, the ofEprn is achieved by offsetting each consecutive course 168 mm (6 % inches). (see Figure 11). ITL't1 6 INCH PATTERN 6 INCHES (152 mm) 6 INCHES (152 mm) 6 INCHES (152 mm) CUTOUTS ALIGN .s , •. EVERY OTHER COURSE SHINGLE STANDARD SIZE SHINGLES 6 e/is INCH 6 e/,s INCHES (167 mm) 6 9/,e INCHES (167 mm) k6 9/,6 INCHES (167 mm) N CUTOUTS ALIGN EVERY OTHER COURSE �. ' :''; FULL -WIDTH SHINGLE METRIC SIZE SHINGLES NOTE: UNDERLAYMENT NOT SHOWN FOR CLARITY Figure 11: Aesthetics of a six-inch pattern Asphalt Shingle Roof Systems 343